Sample records for nasogastric tube insertion

  1. Inflation with air via a facepiece for facilitating insertion of a nasogastric tube: a prospective, randomised, double-blind study.

    PubMed

    Gupta, D; Agarwal, A; Nath, S S; Goswami, D; Saraswat, V; Singh, P K

    2007-02-01

    Insertion of a nasogastric tube is a routine procedure but during anaesthesia it is often difficult and time consuming. One hundred and sixty adults undergoing elective surgery under general anaesthesia were randomly divided into two groups. After induction of anaesthesia, neuromuscular blockade and tracheal intubation, a nasogastric tube was inserted through the nose with the head of the patient in the neutral position, either with or without prior inflation with air via a facepiece attached to a self-inflating bag applied firmly with the face. Insertion of the nasogastric tube was successful in 75/78 (96%) following inflation compared with 54/80 (68%) without inflation (p<0.001). In four patients receiving inflation, a fibreoptic endoscope was passed as far as the upper oesophageal sphincter; this revealed opening of the upper oesophageal sphincter during inflation.

  2. Deaths associated with insertion of nasogastric tubes for enteral nutrition in the medical intensive care unit: Clinical and autopsy findings

    PubMed Central

    Smith, Avery L.; Santa Ana, Carol A.; Fordtran, John S.; Guileyardo, Joseph M.

    2018-01-01

    ABSTRACT It is generally assumed that blind insertion of nasogastric tubes for enteral nutrition in patients admitted to medical intensive care units is safe; that is, does not result in life-threatening injury. If death occurs in temporal association with insertion of a nasogastric tube, caregivers typically attribute it to underlying diseases, with little or no consideration of iatrogenic death due to tube insertion. The clinical and autopsy results in three recent cases at Baylor University Medical Center challenge the validity of these notions. PMID:29904295

  3. Using a nasogastric tube.

    PubMed

    Candy, C

    1986-09-01

    This discussion of the use of a nasogastric tube covers the equipment needed, the method, rehydration and feeding, prolonged nasogastric feeding, and stopping nasogastric feeding. A nasogastric tube is useful when children are unable to drink safely and in sufficient amounts for any of the following reasons: severe dehydration; if intravenous (IV) therapy is unavailable; low birth weight infants; or the child is drowsy or vomiting. Severely malnourished children may be fed initially in this way if they are too weak or anorexic to eat or drink normally. The following equipment is needed: nasogastric tube; lubricating fluid; a syringe; blue litmus paper, if available; adhesive tape; stethoscope if available; and fluid to be given. Explain to the child's parents and the child, if old enough to understand, what will be done; lie infants flat; measure the approximate length from the child's nostril to the ear lobe and then to the top of the abdomen with the tube and mark the position; clean the nostrils to remove the mucus, and lubricate the tip of the tube and gently insert into the nostril; give the child a drink of water if he or she is conscious; continue to pass the tube down until the position marked reaches the nostril; use the syringe to suck up some fluid and test with blue litmus paper to check that the tube is in the stomach; and inject 5-10 ml of fluid (saline or oral rehydration solution, not milk formula) by syringe if satisfied the tube is in the correct position. Where possible, give a continuous drip of fluid. If this is not possible, give frequent small amounts using the syringe as a funnel. If feeding continues for more than 24 hours, clean the nostrils daily with warm water and change the tube to the other nostril every few days. Also keep the mouth very clean with a dilute solution of 8% sodium bicarbonate, if available, or citrus fruit juice. To remove the tube, remove the adhesive tape, take the tube out gently and smoothly, and offer the child a

  4. Cooperative learning using simulation to achieve mastery of nasogastric tube insertion.

    PubMed

    Cason, Melanie Leigh; Gilbert, Gregory E; Schmoll, Heidi H; Dolinar, Susan M; Anderson, Jane; Nickles, Barbara Marshburn; Pufpaff, Laurie A; Henderson, Ruth; Lee, Frances Wickham; Schaefer, John J

    2015-03-01

    Traditionally, psychomotor skills training for nursing students involves didactic instruction followed by procedural review and practice with a task trainer, manikin, or classmates. This article describes a novel method of teaching psychomotor skills to associate degree and baccalaureate nursing students, Cooperative Learning Simulation Skills Training (CLSST), in the context of nasogastric tube insertion using a deliberate practice-to-mastery learning model. Student dyads served as operator and student learner. Automatic scoring was recorded in the debriefing log. Student pairs alternated roles until they achieved mastery, after which they were assessed individually. Median checklist scores of 100% were achieved by students in both programs after one practice session and through evaluation. Students and faculty provided positive feedback regarding this educational innovation. CLSST in a deliberate practice-to-mastery learning paradigm offers a novel way to teach psychomotor skills in nursing curricula and decreases the instructor-to-student ratio. Copyright 2015, SLACK Incorporated.

  5. Evaluation of nasogastric tubes to enable differentiation between upper and lower gastrointestinal bleeding in unselected patients with melena.

    PubMed

    Kessel, Boris; Olsha, Oded; Younis, Aurwa; Daskal, Yaakov; Granovsky, Emil; Alfici, Ricardo

    2016-02-01

    Gastrointestinal (GI) bleeding is a common surgical problem. The aim of this study was to evaluate how insertion of the nasogastric tube may enable differentiation between upper and lower GI bleeding in patients with melena. A retrospective study involving patients admitted to our surgery division with a melena was carried out between the years 2010 and 2012. A total of 386 patients were included in the study. Of these, 279 (72.2%) patients had negative nasogastric aspirate. The sensitivity of examination of nasogastric aspirate to establish the upper GI as the source of bleeding was only 28% and the negative predictive value of a negative nasogastric aspirate was less than 1%. Most patients who initially presented with melena and were found to have upper GI bleeding had a negative nasogastric aspirate. Insertion of a nasogastric tube does not affect the clinical decision to perform upper endoscopy and should not be routinely carried out.

  6. A virtual reality based simulator for learning nasogastric tube placement.

    PubMed

    Choi, Kup-Sze; He, Xuejian; Chiang, Vico Chung-Lim; Deng, Zhaohong

    2015-02-01

    Nasogastric tube (NGT) placement is a common clinical procedure where a plastic tube is inserted into the stomach through the nostril for feeding or drainage. However, the placement is a blind process in which the tube may be mistakenly inserted into other locations, leading to unexpected complications or fatal incidents. The placement techniques are conventionally acquired by practising on unrealistic rubber mannequins or on humans. In this paper, a virtual reality based training simulation system is proposed to facilitate the training of NGT placement. It focuses on the simulation of tube insertion and the rendering of the feedback forces with a haptic device. A hybrid force model is developed to compute the forces analytically or numerically under different conditions, including the situations when the patient is swallowing or when the tube is buckled at the nostril. To ensure real-time interactive simulations, an offline simulation approach is adopted to obtain the relationship between the insertion depth and insertion force using a non-linear finite element method. The offline dataset is then used to generate real-time feedback forces by interpolation. The virtual training process is logged quantitatively with metrics that can be used for assessing objective performance and tracking progress. The system has been evaluated by nursing professionals. They found that the haptic feeling produced by the simulated forces is similar to their experience during real NGT insertion. The proposed system provides a new educational tool to enhance conventional training in NGT placement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Limitations of Routine Verification of Nasogastric Tube Insertion Using X-Ray and Auscultation: Two Case Reports of Life-Threatening Complications.

    PubMed

    Nejo, Takahide; Oya, Soichi; Tsukasa, Tsuchiya; Yamaguchi, Naomi; Matsui, Toru

    2016-12-01

    Several bedside approaches used in combination with thoracoabdominal X-ray are widely used to avoid severe complications that have been reported during nasogastric tube management. Although confirmation by X-ray is considered the gold standard, it is not yet perfect. We present 2 cases of rare complications in which the routine verification methods could not detect all the complications related to the nasogastric tube placement. Case 1 was a 17-year-old male who presented with a brain tumor and repeatedly required nasogastric tube placement. Despite normal auscultatory and X-ray findings, the patient's condition deteriorated rapidly after resuming the enteral nutrition (EN). Computed tomography images showed the presence of hepatic portal venous gas (HPVG). Urgent upper gastrointestinal endoscopy showed esophagogastric submucosal tunneling of the tube that required an emergency open total gastrectomy. Case 2 was a 76-year-old man with long-term EN after stroke. While the last auscultatory verification was normal, he suddenly developed extensive HPVG due to gastric mucosal injury following EN, which resulted in progressive intestinal necrosis, general peritonitis, and death. These 2 cases indicated that routine verification methods consisting of auscultation and X-ray may not be completely reliable, and the awareness of the limitations of these methods should be reaffirmed because expeditious examinations and necessary interventions are critical in preventing life-threatening complications.

  8. Confirming nasogastric tube placement: Is the colorimeter as sensitive and specific as X-ray? A diagnostic accuracy study.

    PubMed

    Mordiffi, Siti Zubaidah; Goh, Mien Li; Phua, Jason; Chan, Yiong-Huak

    2016-09-01

    The effect of delivering enteral nutrition or medications via a nasogastric tube that is inadvertently located in the tracheobronchial tract can cause respiratory complications. Although radiographic examination is accepted as the gold standard for confirming the position of patients' enteral tubes, it is costly, involves risks of radiation, and is not failsafe. Studies using carbon dioxide sensors to detect inadvertent nasogastric tube placements have been conducted in intensive care settings. However, none involved patients in general wards. The objective of this study was to ascertain the diagnostic measure of colorimeter, with radiographic examination as the reference standard, to confirm the location of nasogastric tubes in patients. A prospective observational study of a diagnostic test. This study was conducted in the general wards of an approximately 1100-bed acute care tertiary hospital of an Academic Medical Center in Singapore. Adult patients with nasogastric tubes admitted to the general wards were recruited into the study. The colorimeter was attached to the nasogastric tube to detect for the presence of carbon dioxide, suggestive of a tracheobronchial placement. The exact location of the nasogastric tube was subsequently confirmed by a radiographic examination. A total of 192 tests were undertaken. The colorimeter detected carbon dioxide in 29 tested nasogastric tubes, of which radiographic examination confirmed that four tubes were located in the tracheobronchial tract. The colorimeter failed to detect carbon dioxide in one nasogastric tube that was located in the tracheobronchial tract, thus, demonstrating a sensitivity of 0.80 [95% CI (0.376, 0.964)]. The colorimeter detected absence of carbon dioxide in 163 tested nasogastric tubes in which radiographic examination confirmed 160 gastrointestinal and one tracheobronchial placements, demonstrating a specificity of 0.865 [95% CI (0.808, 0.907)]. The colorimeter detected one tracheobronchial

  9. Development of a clinical practice guideline for testing nasogastric tube placement.

    PubMed

    Peter, Sue; Gill, Fenella

    2009-01-01

    A Perth metropolitan hospital group standardized changes to nasogastric tube placement, including removal of the "whoosh test" and litmus paper, and introduction of pH testing. Two audits were conducted: bedside data collection at a pediatric hospital and a point-prevalence audit across seven hospitals. Aspirate was obtained for 97% of all tests and pH was < or = 5.5 for 84%, validating the practice changes. However, patients on continuous feeds and/or receiving acid-inhibiting medications had multiple pH testing fails. Nasogastric tube placement continues to present a challenge for those high-risk patients on continuous feeds and/or receiving acid-inhibiting medications.

  10. Flow rate of nutrient preparations through nasogastric tubes.

    PubMed Central

    Skidmore, F. D.

    1980-01-01

    Experiments have been carried out in vitro to determine the relationships between the internal diameter of fine-bore nasogastric tubes, the viscosity of nutrient solutions, and the flow rate that can be achieved in the enteral feeding of surgical patients. It was found that such tubes are capable of delivering 3-5 l of nutrient solution in 24 h without a pump. The findings are discussed in relation to the supply of nitrogen and energy to the patient. PMID:6772081

  11. [Effect of nasogastric tube on esophageal mucosa].

    PubMed

    Barinagarrementeria, R; Blancas Valencia, J M; Teramoto Matsubara, O; de la Garza González, S

    1991-01-01

    We studied 30 patients. 20 were males and 10 females. Mean age was 48 year old. Esophageal disease was not present neither gastro-esophageal reflux. Biopsy was taken between 24 hours and 25 days after nasogastric tube (NG) was put into place. Endoscopic findings were: hyperemic mucosa, submucosal hemorrhage, clots, erosions and ulcers near Esophago-gastric junction. Intraepithelial edema, vessel congestion, polymorphonuclear infiltration, fibrin thrombosis of submucosal vessels, ischemia, epithelial regeneration and ulcer were common histologic findings. All endoscopic and histologic alterations were related to the length of time of NG tube contact with the esophageal mucosa. We concluded that NG tube damages the esophageal mucosa by two mechanisms: a) Local irritation that favors b) gastric reflux by decreasing lower esophageal sphincter pressure.

  12. The nasogastric tube syndrome: two case reports and review of the literature.

    PubMed

    Apostolakis, L W; Funk, G F; Urdaneta, L F; McCulloch, T M; Jeyapalan, M M

    2001-01-01

    The nasogastric tube syndrome is a potentially life-threatening complication of an indwelling nasogastric (NG) tube. The syndrome is thought to result from ulceration and infection of the posterior cricoid region with subsequent dysfunction of vocal cord abduction. This dysfunction may present as complete loss of vocal cord abduction manifested as serious airway compromise. Reports of this syndrome are infrequent, with only 29 cases published to date. Two additional cases of nasogastric tube syndrome diagnosed at the University of Iowa Hospitals and Clinics over a 2-year period are presented. A search of MEDLINE (1966 through February 1999), including review of those articles' references identified seven previous publications, including 29 case reports. These 29 cases are reviewed and the findings summarized. Twenty-nine cases of NG tube syndrome are identified, with 16 of these occurring in the preantibiotic period. Including the two cases presented here, 15 contemporary patients are examined. Among these 15 cases, 10 required tracheostomy, on average 8.5 days after NG tube placement. Although the fully manifested syndrome presents quite dramatically, we suspect that a clinical spectrum of severity exists with less severe cases going unrecognized. Consistent with previous reports, we found that direct visualization of the postcricoid region is required to rule out the diagnosis and recommend such action be taken whenever the diagnosis is suspected. Treatment should include establishment of a safe airway, removal of the tube whenever possible, antibiotic therapy, and antireflux therapy.

  13. Using pH testing to confirm nasogastric tube position.

    PubMed

    Earley, Tracy

    In 2004 the MHRA published a directive for all hospitals in the UK to use pH paper in place of litmus paper when testing position of nasogastric tubes (NGT). This article illustrates one trust's implementation of this process of change in order to achieve compliance.

  14. Implementation of an electromagnetic imaging system to facilitate nasogastric and post-pyloric feeding tube placement in patients with and without critical illness.

    PubMed

    Windle, E M; Beddow, D; Hall, E; Wright, J; Sundar, N

    2010-02-01

    Artificial nutrition support is required to optimise nutritional status in many patients. Traditional methods of placing feeding tubes may incur clinical risk and financial costs. A technique facilitating placement of nasogastric and post-pyloric tubes via electromagnetic visual guidance may reduce the need for X-ray exposure, endoscopy time and the use of parenteral nutrition. The present study aimed to audit use of such a system at initial implementation in patients within an acute NHS Trust. A retrospective review was undertaken of dietetic and medical records for the first 14 months of using the Cortrak system. Data were collected on referral origin, preparation of the patient prior to insertion, placement success rates and need for X-ray. Cost analysis was also performed. Referrals were received from primary consultants or consultant intensivists, often on the advice of the dietitian. Fifty-nine percent of patients received prokinetic therapy at the time of placement. Thirty-nine tube placements were attempted. Sixty-nine percent of referrals for post-pyloric tube placement resulted in successful placement. X-ray films were requested for 22% of all attempted post-pyloric placements. Less than half of nasogastric tubes were successfully passed, although none of these required X-ray confirmation. The mean cost per tube insertion attempt was 111 pounds. This system confers advantages, particularly in terms of post-pyloric tube placement, even at this early stage of implementation. A reduction in clinical risk and cost avoidance related to X-ray exposure, the need for endoscopic tube placement and parenteral nutrition have been achieved. The implementation of this system should be considered in other centres.

  15. Nasogastric feeding tube located in the lung. SENSAR case of the trimester.

    PubMed

    2017-01-01

    A clinical case is presented that was communicated to Spanish Notification System on Safety in Anaesthesia and Recovery (SENSAR). Using this communication and its analysis, a strategy is obtained in order to reduce the risks associated with the insertion of a nasogastric tube (NST) for enteral nutrition in adult patients in the post-surgical recovery unit. A description of the incident is presented, an analysis of its causes, and the measures that were introduced in order to avoid similar incidents in the future, as well as to promote a safety culture in the organisation. A description of associated incidents registered in SENSAR is also given. The aim of this work is to describe, analyse and introduce safety measures arising from incidents notified to SENSAR, associated with the insertion and checking of the nutrition NST in adult patients in the post-surgical recovery unit. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Does Bedside Sonography Effectively Identify Nasogastric Tube Placements in Pediatric Critical Care Patients?

    PubMed

    Atalay, Yunus Oktay; Aydin, Ramazan; Ertugrul, Omer; Gul, Selim Baris; Polat, Ahmet Veysel; Paksu, Muhammet Sukru

    2016-12-01

    A nasogastric tube (NGT) insertion is a common procedure in intensive care units, with some serious complications that result from the malposition of the NGT tip. This pilot study was designed to investigate the efficiency of ultrasound in verifying correct NGT placement and to compare these results with radiographic findings. This was a single-center, double-blind prospective study of patients who had received an NGT in the pediatric critical care unit. Twenty-one patients aged 1 month to 18 years were included in this study. All NGTs were inserted by the same critical care physician. After insertion, the physician first confirmed NGT placement by the auscultation of the epigastrium following the insufflation of air. Confirmation was supplemented with an abdominal radiograph. A radiologist who was unaware of the radiographic findings performed bedside sonography on all patients and verified the location of the NGTs. The findings from these 2 physicians were then compared. NGTs were inserted without any complications, and none of the NGTs were positioned in the respiratory tract in any of the patients. All NGT tips were visualized by radiography and sonography with a sensitivity of 100%. Bedside sonography performed by a radiologist is an effective and sensitive diagnostic procedure for confirming the correct NGT position in patients in the pediatric critical care unit.

  17. Compounding rifampin suspensions with improved injectability for nasogastric enteral feeding tube administration.

    PubMed

    de Villiers, Melgardt M; Vogel, Laura; Bogenschutz, Monica C; Fingerhut, Bonnie J; D'Silva, Joseph B; Moore, Anne

    2010-01-01

    Often medications that have to be administered to patients via a nasogastric enteral feeding tubes are only available as tablets and capsules with no suitable commercial liquid alternatives. In such situations, pharmacists and nurses have to compound the tablets and capsule contents into liquid suspension formulations for dosing. The risk of occlusion of the enteral tubes during administration is reduced by employing liquid suspensions that are composed of small and uniform particles, not subject to rapid rates of settling, resistant to caking, and easily and uniformly re-suspended upon agitation. Present techniques often employ a manual process, such as a mortar and pestle, to accomplish the particle size reduction and subsequent incorporation into a suitable liquid diluent. A new compounding device has been invented that employs an automated wet-milling process in a single-use disposable plastic container to compound the suspensions. The two processes were compared using Rifampin capsules and various liquid diluents. A prototype version of the new device was employed in the experiments. The physical characteristics of the compounded suspensions were evaluated by determining sedimentation rate, sedimentation volume, and particle size and shape using laser light scattering, optical microscopy, and scanning electron microscopy techniques. The use characteristic of the compounded suspensions was evaluated using a nasogastric tube inject ability test. The results indicated that suspensions prepared using the new device were more resistant to sedimentation and caking and were easier to re-disperse into a uniform mixture by gentle shaking. The results were a consequence of the particles generated by the new device which were found to be smaller and more uniform in shape and size. The suspensions prepared using the new device did not cause blockage of the enteral feeding tubes in comparison to those prepared using a mortar and pastle. In conclusion, the results indicate

  18. [Is oral rehydration with nasogastric tube more efficient than rehydration with spoon? Preliminary study in children with non-severe dehydration in Joseph-Raseta-Befelatanana Hospital, Madagascar].

    PubMed

    Ravelomanana, T; Rabeatoandro, S; Randrianaivo, N; Ratsimbazafy, A; Raobijaona, H; Barennes, H

    2010-05-01

    Since its recommendation by WHO, Oral Rehydration Solutions (ORS) contributed in reducing the rate of mortality due to acute gastroenteritis. In Madagascar, the rate of lethality imputed to gastroenteritis is about 3%. Rehydration can be performed either by using spoons which reliability is unsure because of parents' potential inobservance and child's refusal, or by nasogastric tube. The nasogastric tube may resolve these obstacles at the hospital. We realized a preliminary study to evaluate the efficacy and the safety of nasogastric tube and spoon administration of the ORS in rehydration of child with moderate post-gastroenteritis dehydration. This is an open comparative study realized in the Pediatric Unit at the Joseph-Raseta-Befelatanana Hospital from the 21 January to 21 May 2008. Main outcomes was the proportion of rehydrated children at 4 hours, other were: failure at 8 hours, duration and volume of SRO, side effects. Fifty-three children from 4-month to 4-year old among 1306 patients were recruited and forty-seven patients were included. Nine patients failed (4 children received ORS by spoon and 5 children by nasogastric tube). The use of spoon was more effective: 62.5% of the patients were rehydrated at the fourth hour versus 39.3% in nasogastric tube group (P = 0.04). Making debit constant presents difficulties in rehydration with nasogastric tube (44.4 %). Tolerance of nasogastric tube is generally good but 16.7% children get out their tube during this study. No ORS' inhalation was observed with both routes. No false passage or tube or ORS rejection was recorded in both techniques. This study shows that using spoon to rehydrate is more effective for the rehydration of moderate dehydration. The use of nasogastric tube needs more surveillance.

  19. Determination of a practical pH cutoff level for reliable confirmation of nasogastric tube placement.

    PubMed

    Gilbertson, Heather Ruth; Rogers, Elizabeth Jessie; Ukoumunne, Obioha Chukwunyere

    2011-07-01

    Enteral feeding is a common method of nutrition support when oral intake is inadequate. Confirmation of correct nasogastric (NG) tube placement is essential. Risks of morbidity/mortality associated with misplacement in the lung are well documented. Studies indicate that pH ≤ 4 confirms gastric aspirate, but in pediatrics, a pH of gastric aspirate is often >4. The goal of this study was to determine a reliable and practical pH value to confirm NG tube placement, without increasing the risk of not identifying a misplaced NG tube. Pediatric inpatients older than 4 weeks receiving enteral nutrition (nasogastric or gastrostomy) were recruited over 9 months. Aspirate samples were pH tested at NG tube placement and before feedings. If pH >4, NG tube position was confirmed by chest radiograph or further investigations. In addition, intensive care unit (ICU) patients who required endotracheal suctioning were recruited, and endotracheal aspirate samples were pH tested. A total of 4,330 gastric aspirate samples (96% nasogastric) were collected from 645 patients with a median (interquartile range [IQR]) age of 1.0 years (0.3-5.2 years). The mean (standard deviation [SD]) pH of these gastric samples was 3.6 (1.4) (range, 0-9). pH was >4 in 1,339 (30.9%) gastric aspirate samples, and of these, 244 were radiographed, which identified 10 misplaced tubes (1 with pH 5.5). A total of 65 endotracheal aspirate samples were collected from 19 ICU patients with a median (IQR) age of 0.6 years (0.4-5.2 years). The mean (SD) pH of these samples was 8.4 (0.8) (range, 6-9.5). Given that the lowest pH value of endotracheal aspirate sample was 6, and a misplaced NG tube was identified with pH 5.5, it is proposed that a gastric aspirate pH ≤ 5 is a safer, reliable, and practical cutoff in this population.

  20. Successful treatment of severe Clostridium difficile infection by administration of crushed fidaxomicin via a nasogastric tube in a critically ill patient.

    PubMed

    Arends, Sven; Defosse, Jerome; Diaz, Cori; Wappler, Frank; Sakka, Samir G

    2017-02-01

    To report the successful use of crushed fidaxomicin via a nasogastric tube for treatment of a severe Clostridium difficile infection in a critically ill patient. Clinical observation of a patient, images of abdominal computed tomography, antimicrobial therapy and course of infection parameters. Relevant information contained in the medical observation of the patient and selection of image and laboratory parameters performed in the patient. We report a case of a 79-year old patient who developed septic shock with an increasing need for norepinephrine and acute renal failure due to a severe Clostridium difficile infection. Antimicrobial therapy with vancomycin via a nasogastric tube and metronidazole i.v. did not lead to improvement, infection parameters further increased, and the clinical condition became increasingly impaired. After 10 days, antimicrobial therapy was changed to fidaxomicin, crushed and administered via nasogastric tube. Within 24hours, infection parameters decreased. Further diarrhoea ceased and stool samples were negative for Clostridium difficile antigen. Our case confirms that administration of fidaxomicin via a nasogastric tube was safe and effective in this patient. Further studies are needed to evaluate the efficacy of this strategy in critically ill patients systematically. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  1. Gastric digestion of α-lactalbumin in adult human subjects using capsule endoscopy and nasogastric tube sampling.

    PubMed

    Sullivan, Louise M; Kehoe, Joseph J; Barry, Lillian; Buckley, Martin J M; Shanahan, Fergus; Mok, K H; Brodkorb, André

    2014-08-28

    In the present study, structural changes in the milk protein α-lactalbumin (α-LA) and its proteolysis were investigated for the potential formation of protein-fatty acid complexes during in vivo gastric digestion. Capsule endoscopy allowed visualisation of the digestion of the test drinks, with nasogastric tubes allowing sampling of the gastric contents. A total of ten healthy volunteers had nasogastric tubes inserted into the stomach and ingested test drinks containing 50 g/l of sucrose and 25 g/l of α-LA with and without 4 g/l of oleic acid (OA). The samples of gastric contents were collected for analysis at 3 min intervals. The results revealed a rapid decrease in the pH of the stomach of the subjects. The fasting pH of 2·31 (SD 1·19) increased to a pH maxima of pH 6·54 (SD 0·29) after ingestion, with a subsequent decrease to pH 2·22 (SD 1·91) after 21 min (n 8). Fluorescence spectroscopy and Fourier transform IR spectroscopy revealed partial protein unfolding, coinciding with the decrease in pH below the isoelectric point of α-LA. The activity of pepsin in the fasting state was found to be 39 (SD 12) units/ml of gastric juice. Rapid digestion of the protein occurred: after 15 min, no native protein was detected using SDS-PAGE; HPLC revealed the presence of small amounts of native protein after 24 min of gastric digestion. Mirocam® capsule endoscopy imaging and video clips (see the online supplementary material) revealed that gastric peristalsis resulted in a heterogeneous mixture during gastric digestion. Unfolding of α-LA was observed during gastric transit; however, there was no evidence of a cytotoxic complex being formed between α-LA and OA.

  2. Insert sleeve prevents tube soldering contamination

    NASA Technical Reports Server (NTRS)

    Stein, J.

    1966-01-01

    Teflon sleeve insert prevents contamination of internal tube surfaces by solder compound during soldering operations that connect and seal the tube ends. The sleeve insert is pressed into the mating tube ends with a slight interference fit.

  3. Evaluation of intensivist-nurses' knowledge concerning medication administration through nasogastric and enteral tubes.

    PubMed

    Mota, Maria Lurdemiler Sabóia; Barbosa, Islene Victor; Studart, Rita Mônica Borges; Melo, Elizabeth Mesquita; Lima, Francisca Elisângela Teixeira; Mariano, Fabíola Amaro

    2010-01-01

    This study evaluates the knowledge of nurses working in intensive care units concerning recommendations for the proper administration of medication through nasogastric and enteral tubes. This exploratory-descriptive study with a quantitative approach was carried out with 49 nurses in an intensive care unit of a tertiary hospital in Fortaleza, CE, Brazil. A total of 36.7% of nurses reported they disregard the dosage forms provided by the pharmacy at the time of administering the medication through tubes. Metal, wood, or a plastic mortar is the method most frequently reported (42.86%) for crushing prescribed solid forms; 32.65% leave the drugs in 20 ml of water until dissolved; 65.3% place the responsibility for choosing the pharmaceutical formulation and its correlation with the tube site, either into the stomach or into the intestine, on the physician. The results indicate there is a gap between specific literature on medication administered through tubes and knowledge of nurses on the subject.

  4. Nasogastric hydration versus intravenous hydration for infants with bronchiolitis: a randomised trial.

    PubMed

    Oakley, Ed; Borland, Meredith; Neutze, Jocelyn; Acworth, Jason; Krieser, David; Dalziel, Stuart; Davidson, Andrew; Donath, Susan; Jachno, Kim; South, Mike; Theophilos, Theane; Babl, Franz E

    2013-04-01

    Bronchiolitis is the most common lower respiratory tract infection in infants and the leading cause of hospital admission. Hydration is a mainstay of treatment, but insufficient evidence exists to guide clinical practice. We aimed to assess whether intravenous hydration or nasogastric hydration is better for treatment of infants. In this multicentre, open, randomised trial, we enrolled infants aged 2-12 months admitted to hospitals in Australia and New Zealand with a clinical diagnosis of bronchiolitis during three bronchiolitis seasons (April 1-Oct 31, in 2009, 2010, and 2011). We randomly allocated infants to nasogastric hydration or intravenous hydration by use of a computer-generated sequence and opaque sealed envelopes, with three randomly assigned block sizes and stratified by hospital site and age group (2-<6 months vs 6-12 months). The primary outcome was length of hospital stay, assessed in all randomly assigned infants. Secondary outcomes included rates of intensive-care unit admission, adverse events, and success of insertion. This trial is registered with the Australian and New Zealand clinical trials registry, ACTRN12605000033640. Mean length of stay for 381 infants assigned nasogastric hydration was 86·6 h (SD 58·9) compared with 82·2 h (58·8) for 378 infants assigned intravenous hydration (absolute difference 4·5 h [95% CI -3·9 to 12·9]; p=0·30). Rates of admission to intensive-care units, need for ventilatory support, and adverse events did not differ between groups. At randomisation, seven infants assigned nasogastric hydration were switched to intravenous hydration and 56 infants assigned intravenous hydration were switched to nasogastric hydration because the study-assigned method was unable to be inserted. For those infants who had data available for successful insertion, 275 (85%) of 323 infants in the nasogastric hydration group and 165 (56%) of 294 infants in the intravenous hydration group required only one attempt for successful

  5. Comparison of complication rates in dogs with nasoesophageal versus nasogastric feeding tubes.

    PubMed

    Yu, Melissa K; Freeman, Lisa M; Heinze, Cailin R; Parker, Valerie J; Linder, Deborah E

    2013-01-01

    To compare complication rates between nasoesophageal (NE) and nasogastric (NG) feeding tubes in dogs. Retrospective study. University referral veterinary hospital. A total of 46 dogs that were fed through a NE (n = 28) or NG (n = 18) tube between January 2007 and December 2011 and that also had either thoracic radiography or computed tomography performed so that location of the distal tip of the tube in either the esophagus or stomach could be confirmed. None. The medical record of each eligible case was reviewed and data recorded included signalment, underlying disease, body weight, body condition score, medications, duration of feeding, diet used, and complications observed (ie, vomiting, regurgitation, diarrhea, early tube removal, clogged tube, epistaxis, pulmonary aspiration, hyperglycemia, and refeeding syndrome). Dogs with NE tubes were significantly younger than dogs with NG tubes (P = 0.03) but there were no other significant differences in signalment, underlying disease, medications, duration of anorexia, percent of resting energy requirement achieved, or change in weight during tube feeding. There also was no significant difference between the NE and NG groups for any of the recorded complications. Significantly fewer dogs in the NE group died or were euthanized (3/28) compared to the NG group (7/18; P = 0.02) but outcome was not associated with age, underlying disease, or any of the recorded tube complications. This study did not identify a difference in complication rate between NE and NG feeding tubes in dogs. Additional studies are required to determine the optimal terminal location of feeding tubes in dogs. © Veterinary Emergency and Critical Care Society 2013.

  6. Extraction of the plasticizers diethylhexylphthalate and polyadipate from polyvinylchloride nasogastric tubes through gastric juice and feeding solution.

    PubMed

    Subotic, Ulrike; Hannmann, Torsten; Kiss, Matthias; Brade, Joachim; Breitkopf, Katja; Loff, Steffan

    2007-01-01

    Except for polyadipate, which is used as an alternative in polyvinylchloride (PVC) feeding tubes, diethylhexylphthalate (DEHP) is the plasticizer used almost exclusively in PVC medical products. A clear response to the chronic intake of DEHP has been shown in several organ systems from different species. In the present study, we compared the extraction of DEHP and polyadipate from PVC gastric tubes. An in vivo setting was simulated. We used 5 cm of PVC nasogastric tubes containing DEHP or polyadipate, which were incubated with gastric juice for 1 week and a feeding solution for 4 weeks. The leakage of these plasticizers was measured daily in the gastric juice group and weekly in the feeding solution group. The amount of plasticizer extracted was compared between groups and days. In the feeding solution group, the extraction of DEHP ranged from 200 to 542 microg after 1 week and from 660 to 1700 microg after 4 weeks. The extraction of polyadipate was 10 times lower than that of DEHP. In the gastric juice group, extracted DEHP ranged from 635 to 1043 microg, whereas the extraction of polyadipate was 100 times lower. Within 1 week, the extraction of DEHP from a 5-cm PVC tube reaches up to 1 mg. Extrapolated, this represents an in vivo load of up to 4 mg. The load accumulated by a newborn in an intensive care unit can therefore easily reach several milligrams of DEHP per day. Polyadipate nasogastric tubes may therefore be an alternative and help to reduce the daily load of DEHP.

  7. Laparoscopic insertion of the Moss feeding tube.

    PubMed

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  8. Chest tube insertion

    MedlinePlus

    ... leaks from inside the lung into the chest ( pneumothorax ) Fluid buildup in the chest (called a pleural ... on the reason a chest tube is inserted. Pneumothorax most often improves, but sometimes surgery is needed ...

  9. [Study of bacterial flora in the oral cavity and stomach of elderly patients receiving nasogastric tube feeding].

    PubMed

    Matsuura, T; Suzuki, K; Yamakoshi, M; Yamamoto, T; Yamamoto, T; Yoshitomo, K; Tonegawa, K; Ariga, K; Odawara, F

    1997-05-01

    To investigate the significance of oropharyngeal flora and gastric flora in elderly patients receiving nasogastric tube feeding, throat secretions and gastric aspirates were cultured and the pH of the latter was measured. Of 116 bacterial isolates from throat secretions of 27 elderly patients, 30 were beta-streptococci and 28 were Pseudomonas aeruginosa. Bacteria isolated from gastric aspirates numbered 86 and 24 (27.9%) of them were the same species as those found in the throat secretions. Patients with gastric pH were below 3.5 had significantly lower concentrations of gram-negative bacili in gastric aspirates. We also studied oropharyngeal flora in 33 elderly patients who were admitted to Nagoyashi Koseiin Geriatric Hospital. The major bacterial isolates from throat swabs of bedridden patients were gram-negative bacilli and beta-streptococci, especially group B streptococci (GBS). We measured the level of antibody to GBS in these patients. Those from whom GBS were isolated had high titers. These results suggest that in elderly patients receiving enteral nasogastric) tube feeding, large numbers of bacteria colonize the oral cavity and stomach. The measurement of type-specific antibody to GBS may be useful in managing such patients.

  10. Interventions for maintaining nasogastric feeding after stroke: An integrative review of effectiveness and acceptability.

    PubMed

    Mahoney, Catherine; Veitch, Linda

    2018-02-01

    To investigate the effectiveness and acceptability of interventions for maintaining nasogastric tubes in adult stroke patients. Internationally, incidence of cerebral vascular disease continues to increase and stroke is the largest cause of complex disability in adults. Dysphagia is common following a stroke which necessitates feeding via a nasogastric tube. Nasogastric tubes are not well tolerated by stroke patients and may be frequently dislodged. Hence, interventions such as tape, the nasal bridle/loop or hand mittens may be used to maintain nasogastric tube position. However, evidence around the effectiveness and acceptability of these interventions has not been reviewed and synthesised. Integrative literature review. Database searches in MEDLINE, PubMed, CINAHL, Scopus, Cochrane and EMBASE; manual reference list searches. Seven studies met the eligibility criteria and were included in the review. Evidence for the effectiveness of nasal bridle/loop and hand mittens to maintain nasogastric tube position in patients after a stroke is spare and methodologically poor, and especially limited around hand mittens use. There is insufficient evidence about the acceptability of both nasal bridle/loop and hand mittens among stroke patients. Current clinical practice is underpinned by assumptions around the acceptability of nasal bridle/loop and hand mittens to secure nasogastric tubes. This results in reliance on consensual judgement between professional, patients and their families to guide their use among individuals with dysphagia after stroke. Further research is required to assess the effectiveness of hand mittens and acceptability of both nasal bridle/loop and hand mittens among stroke patients to inform guideline development. Given the lack of evidence on the acceptability of hand mittens and nasal bridle/loop among stroke patients to inform evidence-based guidelines and protocols, healthcare professionals should reach consensus on their use by exercising clinical

  11. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center

    PubMed Central

    2012-01-01

    Background This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. Methods The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. Results The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Conclusions Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed. PMID:22691418

  12. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center.

    PubMed

    Kim, Hyung Min; So, Byung Hak; Jeong, Won Jung; Choi, Se Min; Park, Kyu Nam

    2012-06-12

    This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed.

  13. Discovering Innovation at the Intersection of Undergraduate Medical Education, Human Factors, and Collaboration: The Development of a Nasogastric Tube Safety Pack.

    PubMed

    Taylor, Natalie; Bamford, Thomas; Haindl, Cornelia; Cracknell, Alison

    2016-04-01

    Significant deficiencies exist in the knowledge and skills of medical students and residents around health care quality and safety. The theory and practice of quality and safety should be embedded into undergraduate medical practice so that health care professionals are capable of developing interventions and innovations to effectively anticipate and mitigate errors. Since 2011, Leeds Medical School in the United Kingdom has used case study examples of nasogastric (NG) tube patient safety incidents within the undergraduate patient safety curriculum. In 2012, a medical undergraduate student approached a clinician with an innovative idea after undertaking an NG tubes root cause analysis case study. Simultaneously, a separate local project demonstrated low compliance (11.6%) with the United Kingdom's National Patient Safety Agency NG tubes guideline for use of the correct method to check tube position. These separate endeavors led to interdisciplinary collaboration between a medical student, health care professionals, researchers, and industry to develop the Initial Placement Nasogastric Tube Safety Pack. Human factors engineering was used to inform pack design to allow guideline recommendations to be accessible and easy to follow. A timeline of product development, mapped against key human factors and medical device design principles used throughout the process, is presented. The safety pack has since been launched in five UK National Health Service (NHS) hospitals, and the pack has been introduced into health care professional staff training for NG tubes. A mixed-methods evaluation is currently under way in five NHS organizations.

  14. Continuous nasogastric milk feeding versus intermittent bolus milk feeding for premature infants less than 1500 grams.

    PubMed

    Premji, Shahirose S; Chessell, Lorraine

    2011-11-09

    Milk feedings can be given via nasogastric tube either intermittently, typically over 10 to 20 minutes every two or three hours, or continuously, using an infusion pump. Although theoretical benefits and risks of each method have been proposed, effects on clinically important outcomes remain uncertain. To examine the evidence regarding the effectiveness of continuous versus intermittent bolus nasogastric milk feeding in premature infants less than 1500 grams. Searches were performed of the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 3, 2011), MEDLINE, CINAHL and HealthSTAR up to July 2011. Randomised and quasi-randomised clinical trials comparing continuous versus intermittent bolus nasogastric milk feeding in premature infants less than 1500 grams. Two review authors independently assessed all trials for relevance and methodologic quality. The standard methods of the Cochrane Neonatal Review Group were used to extract data. Overall, the seven included trials, involving 511 infants, found no differences in time to achieve full enteral feeds between feeding methods (weighted mean difference (WMD) 2 days; 95% CI -0.3 to 3.9) . In the subgroup analysis of those studies comparing continuous nasogastric versus intermittent bolus nasogastric milk feedings the findings remained unchanged (WMD 2 days, 95% CI -0.4 to 4.1). There was no significant difference in somatic growth and incidence of NEC between feeding methods irrespective of tube placement. One study noted a trend toward more apneas during the study period in infants fed by the continuous tube feeding method compared to those fed by intermittent feedings delivered predominantly by orogastric tube placements [mean difference (MD) 14.0 apneas during study period; 95% CI -0.2 to 28.2]. In subgroup analysis based on weight groups, one study suggested that infants less than 1000 grams and 1000 to 1250 grams birth weight gained weight faster when fed by the continuous

  15. A Non-invasive Real-time Localization System for Enhanced Efficacy in Nasogastric Intubation.

    PubMed

    Sun, Zhenglong; Foong, Shaohui; Maréchal, Luc; Tan, U-Xuan; Teo, Tee Hui; Shabbir, Asim

    2015-12-01

    Nasogastric (NG) intubation is one of the most commonly performed clinical procedures. Real-time localization and tracking of the NG tube passage at the larynx region into the esophagus is crucial for safety, but is lacking in current practice. In this paper, we present the design, analysis and evaluation of a non-invasive real-time localization system using passive magnetic tracking techniques to improve efficacy of the clinical NG intubation process. By embedding a small permanent magnet at the insertion tip of the NG tube, a wearable system containing embedded sensors around the neck can determine the absolute position of the NG tube inside the body in real-time to assist in insertion. In order to validate the feasibility of the proposed system in detecting erroneous tube placement, typical reference intubation trajectories are first analyzed using anatomically correct models and localization accuracy of the system are evaluated using a precise robotic platform. It is found that the root-mean-squared tracking accuracy is within 5.3 mm for both the esophagus and trachea intubation pathways. Experiments were also designed and performed to demonstrate that the system is capable of tracking the NG tube accurately in biological environments even in presence of stationary ferromagnetic objects (such as clinical instruments). With minimal physical modification to the NG tube and clinical process, this system allows accurate and efficient localization and confirmation of correct NG tube placement without supplemental radiographic methods which is considered the current clinical standard.

  16. Accuracy of biochemical markers for predicting nasogastric tube placement in adults--a systematic review of diagnostic studies.

    PubMed

    Fernandez, Ritin S; Chau, Janita Pak-Chun; Thompson, David R; Griffiths, Rhonda; Lo, Hoi-Shan

    2010-08-01

    The objective of this study was to investigate the diagnostic performance of biochemical tests used to determine placement of nasogastric (NG) tubes after insertion in adults. A systematic review of diagnostic studies was undertaken. A literature search of the bibliographic databases and the World Wide Web was performed to locate original diagnostic studies in English or Chinese on biochemical markers for detecting NG tube location. Studies in which one or more different tests were evaluated with a reference standard, and diagnostic values were reported or could be calculated were included. Two reviewers independently checked all abstracts and full text studies for inclusion criteria. Included studies were assessed for their quality using the QUADAS tool. Study features and diagnostic values were extracted from the included studies. Of the 10 studies included in this review, seven investigated the diagnostic accuracy of pH, one investigated the diagnostic accuracy of pH and bilirubin respectively, two a combination of pH and bilirubin and one a combination of pH, pepsin and trypsin levels in identifying NG tube location. All studies used X-rays as the reference standard for comparison. Pooled results demonstrated that a pH of tubes located in the stomach. However, a pH value of tubes in intestine. However, the ability of the test to correctly identify gastric placement of feeding tubes was relatively low (sensitivity<0.90). Due to the heterogeneity of the studies and small sample sizes, conclusions about the diagnostic performance of the different tests cannot be drawn. Better designed studies exploring the accuracy of diagnostic tests are needed to improve

  17. Confirmation of nasogastric tube position by pH testing.

    PubMed

    Taylor, S J; Clemente, R

    2005-10-01

    In 2004, the Medicines and Healthcare products Regulatory Agency (MHRA) advised that nasogastric (NG) tube position should be confirmed using pH strips or paper. However, gastric pH is raised by the use of H2-blockers and proton-pump inhibitors (PPIs) potentially producing false negative pH tests resulting in delayed feeding. In addition, colorimetric differentiation using pH strips may be more prone to bias and inaccuracy than direct pH measurements largely used to establish the threshold. To quantify this problem a 1 day survey of all the patients requiring NG and nasointestinal (NI) feeding was undertaken, to establish the numbers of patients receiving H2-Blockers or PPIs, with or without a safe swallow and the methods currently being used to confirm tube positioning. A second observational study was performed to establish the accuracy of six pH strips available to NHS trusts against four unlabelled pH solutions. Forty-two per cent of patients receiving NG feeding were on H2-blockers or PPIs, including 13% who had a safe swallow for acidic drinks that could be subsequently aspirated to confirm position. In the second study 'testers' correctly identified pH's 3, 4, 5 and 6 with Mackery-Nagel 0-6, BDH 0-6 and 0-14 strips but overestimated pH 4 as pH 5 with Johnson 0-11 paper, underestimated pH 6 as pH 5 with Pehanon 0-12 paper and with Litmus classified pH 3-5 as acid (all), but half also classified pH 6 as acid. Theoretically 29% of NG tube positions could not be confirmed by pH testing because of the usage of PPIs or H2-blockers and lack of swallow. Some pH strips are either inaccurate or their result misinterpreted by staff. Large surveys and trials of the actual efficacy and accuracy of pH testing are required.

  18. [Nasogastric rehydration for treating children with gastroenteritis].

    PubMed

    Rébeillé-Borgella, B; Barbier, C; Moussaoui, R; Faisant, A; Michard-Lenoir, A-P; Rubio, A

    2017-06-01

    When oral rehydration is not feasible, enteral rehydration via the nasogastric route has been the ESPGHAN recommended method of rehydration since 2008, rather than intravenous rehydration (IVR), for children with acute gastroenteritis. However, these recommendations are rarely followed in France. Since 2011, in case of failure of oral rehydration, enteral rehydration has been used as a first-line therapy in the Children's Emergency Department at the Grenoble-Alpes University Hospital. The aims of the study were to compare the length of the hospital stay, the duration of initial rehydration, and the incidence of complications and failure with the use of enteral nasogastric versus intravenous rehydration. This study compared two cohorts of children (<3 years of age) with mild-to-moderate dehydration caused by acute gastroenteritis and failure of rehydration via the oral route. The first group (winter 2010-2011) was managed according to the previous protocol (intravenous rehydration). The second group (winter 2011-2012) was managed according the new protocol (nasogastric tube rehydration [NGR]). The rest of the gastroenteritis management was identical in both groups. A total of 132 children were included, 65 were treated with nasogastric tube rehydration (NGR) and 67 with intravenous rehydration. There was a significant reduction in the duration of hospitalization in the post-emergency unit in the NGR group: 23.6h vs 40.1h (P<0.05). The duration of initial rehydration was also significantly reduced (10.5h vs 22.0h). There was no significant difference regarding serious adverse events. However, the NGR group presented more mild adverse events (22 vs 7, P<0.05) and more treatment failures (15.3% vs 3%, P=0.013). Nasogastric rehydration reduces the duration of rehydration and the length of the hospital stay without increasing the incidence of serious adverse events for dehydrated children hospitalized for acute gastroenteritis. Copyright © 2017 Elsevier Masson SAS. All

  19. Gastrostomy versus nasogastric tube feeding for chemoradiation patients with head and neck cancer: the TUBE pilot RCT.

    PubMed

    Paleri, Vinidh; Patterson, Joanne; Rousseau, Nikki; Moloney, Eoin; Craig, Dawn; Tzelis, Dimitrios; Wilkinson, Nina; Franks, Jeremy; Hynes, Ann Marie; Heaven, Ben; Hamilton, David; Guerrero-Urbano, Teresa; Donnelly, Rachael; Barclay, Stewart; Rapley, Tim; Stocken, Deborah

    2018-04-01

    Approximately 9000 new cases of head and neck squamous cell cancers (HNSCCs) are treated by the NHS each year. Chemoradiation therapy (CRT) is a commonly used treatment for advanced HNSCC. Approximately 90% of patients undergoing CRT require nutritional support via gastrostomy or nasogastric tube feeding. Long-term dysphagia following CRT is a primary concern for patients. The effect of enteral feeding routes on swallowing function is not well understood, and the two feeding methods have, to date (at the time of writing), not been compared. The aim of this pilot randomised controlled trial (RCT) was to compare these two options. This was a mixed-methods multicentre study to establish the feasibility of a RCT comparing oral feeding plus pre-treatment gastrostomy with oral feeding plus as-required nasogastric tube feeding in patients with HNSCC. Patients were recruited from four tertiary centres treating cancer and randomised to the two arms of the study (using a 1 : 1 ratio). The eligibility criteria were patients with advanced-staged HNSCC who were suitable for primary CRT with curative intent and who presented with no swallowing problems. The primary outcome was the willingness to be randomised. A qualitative process evaluation was conducted alongside an economic modelling exercise. The criteria for progression to a Phase III trial were based on a hypothesised recruitment rate of at least 50%, collection of outcome measures in at least 80% of those recruited and an economic value-of-information analysis for cost-effectiveness. Of the 75 patients approached about the trial, only 17 consented to be randomised [0.23, 95% confidence interval (CI) 0.13 to 0.32]. Among those who were randomised, the compliance rate was high (0.94, 95% CI 0.83 to 1.05). Retention rates were high at completion of treatment (0.94, 95% CI 0.83 to 1.05), at the 3-month follow-up (0.88, 95% CI 0.73 to 1.04) and at the 6-month follow-up (0.88, 95% CI 0.73 to 1.04). No serious adverse

  20. Nasogastric tube versus gastrostomy tube for gastric decompression in abdominal surgery: a prospective, randomized trial comparing patients' tube-related inconvenience.

    PubMed

    Hoffmann, S; Koller, M; Plaul, U; Stinner, B; Gerdes, B; Lorenz, W; Rothmund, M

    2001-11-01

    Perioperative decompression of the stomach is still a common procedure and can be achieved using either nasogastric tubes (NTs) or gastrostomy tubes (GTs). While both procedures appear to be equally effective, some authors believe that NTs are less convenient for patients than GTs. However, to date, no reliable prospective data are available on this issue. We conducted a prospective, randomized trial comparing NTs versus GTs with a total of 110 patients undergoing elective colon surgery. The primary outcome measure was the patient's tube-related inconvenience and pain, assessed in a standardized interview on day 2 after surgery and quantified by means of a visual-analog scale (VAS). A questionnaire including the EORTC QLQ-C30 and additional items regarding retrospective tube-related judgements was administered on the day of discharge and 4 weeks after discharge. Secondary endpoints were the therapy-related morbidity and general complications. When patients were asked which of their drainage tubes (all patients had three or four drainage tubes, such as decompression drains, urinary drains, central venous line) was most inconvenient, 43% (CI 33-53%) in the NT group reported that the NT was most inconvenient, while only 4% (CI 1-10%) of the GT patients judged the GT most inconvenient ( P<0.001, Chi(2) test). This effect was also found in VAS ratings of inconvenience and discomfort ( P<0.01). Also postoperatively (p.o.), NT patients evidenced less preference for their tube system (day 2 p.o.: 71%, CI 61-80%; 4 weeks p.o.: 66%, CI 56-75%) than did GT patients (day 2 p.o.: 94%, CI 88-98%; 4 weeks p.o.: 91% CI 84-96%); again, these differences were statistically significant ( P<0.02; Chi(2) test). No differences between groups emerged regarding global quality of life or conventional clinical outcomes. This prospective randomized trial supports the clinical observation that NT causes more subjective inconvenience than GT. In cases when a prolonged postoperative ileus is

  1. Underwater-seal nasogastric tube drainage to relieve gastric distension caused by air swallowing.

    PubMed

    Solomon, A W; Bramall, J C; Ball, J

    2011-02-01

    Air swallowing can occur as a psychogenic phenomenon, because of abnormal anatomy, or during non-invasive positive pressure ventilation. Gross distension of the stomach with air can have severe consequences for the respiratory and gastrointestinal systems. We report the case of a 62-year-old man with severe dynamic hyperinflation due to chronic obstructive pulmonary disease, who developed respiratory failure requiring intubation a few hours after radical prostatectomy. Following a percutaneous tracheostomy and weaning of sedation on day six, his abdomen began to enlarge progressively. X-rays revealed massive gastric distension due to air swallowing, which continued despite all efforts to optimise therapy. The use of an underwater seal drainage system on a nasogastric tube improved ventilation and ultimately aided weaning from mechanical support. © 2010 The Authors. Anaesthesia © 2010 The Association of Anaesthetists of Great Britain and Ireland.

  2. Health Instruction Packages: Specific Nursing Skills.

    ERIC Educational Resources Information Center

    Bates, Clarice; And Others

    Text, illustrations, and exercises are utilized in a set of five learning modules designed to instruct nursing students in a variety of clinical skills. The first module, "Down the Tube: Insertion of a Nasogastric Tube" by Clarice Bates, describes materials and procedures used to insert a nasogastric tube through the nose and esophagus…

  3. Role of the Nasogastric Tube and Lingzhi (Ganoderma lucidum) in Palliative Care.

    PubMed

    Wang, Xiaohui; Huang, Youyi; Radha Krishna, Lalit; Puvanendran, Rukshini

    2016-04-01

    Decision-making on behalf of an incapacitated patient at the end of life is a complex process, particularly in family-centric societies. The situation is more complex when attempts are made to accommodate Eastern concepts of end-of-life care with more conventional Western approaches. In this case report of an incapacitated 74-year-old Singaporean man of Malay descent with relapsed Stage 4 diffuse large B cell lymphoma who was without an established lasting power of attorney, we highlight the difficult deliberations that ensue when the patient's family, acting as his proxy, elected to administer lingzhi through his nasogastric tube (NGT). Focusing on the questions pertaining to end-of-life decision-making in Asia, we consider the issues surrounding the use of NGT and lingzhi in palliative care (PC) and the implementation of NGT for administering lingzhi in a PC setting, particularly in light of a dearth of data on such treatment measures among PC patients. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  4. Conservative Surgical Approach to Restore Necrotic Columella in Patients Undergoing Neonatal Usage of Nasogastric Tube.

    PubMed

    Inchingolo, Francesco; Abenavoli, Fabio Massimo; De Angelis, Francesca; Orefici, Alessandro; Santacroce, Luigi; Dipalma, Gianna

    2017-01-01

    A common complication, related to the use of nasogastric tube during the 1 st day of life, is the necrosis of the columella. Esthetic damage in the early age typically leads to a healing request with very high result expectations. We aimed to develop and use an innovative surgical technique. We used our technique in four cases. Our technique requires two flaps designed with two paramedian release incisions. The two flaps will be sutured to what remains of the fibrous septum; finally, the two flaps will be sutured together in the medial region. Postoperative course was devoid of any complication. All patients gained esthetic improvements and an increase in the volume of the columella on the sagittal and frontal planes. This technique allows a conservative approach with low donor site morbidity and rapid postoperative course.

  5. Implementation of the evidence review on best practice for confirming the correct placement of nasogastric tube in patients in an acute care hospital.

    PubMed

    Tho, Poh Chi; Mordiffi, Siti; Ang, Emily; Chen, Helen

    2011-03-01

    Nasogastric (NG) tube is a device passed through the gastrointestinal tract of patients for the purpose of feeding, gastric decompression and medication administration. However, a small risk involved in the process is that the tube may be misplaced into the trachea during insertion or may get displaced at a later stage, leading to disastrous results. Recent adverse incidences arising out of the misplacement of NG tube raised concerns among the nursing and medical community and the Patient Safety Officer of the hospital. The Evidence Based Nursing Unit, in collaboration with some of the key nursing leaders in nursing administration, was tasked to explore and institute the current best practice in confirming the correct placement of NG tube. The aim of this project was to institute the best practice to confirm the correct placement of NG tube in patients in an acute care hospital setting. The project comprised of a few stages. The first stage involved reviewing the existing recommendations and guidelines on the methods for checking correct NG tube placement. The second stage involved incorporation of the change of practice into the clinical setting. The final stage was to monitor and evaluate the impact of the new practice on the patients, nurses and other healthcare professionals. Evidence search from guidelines and journals supported the test that used pH indicator instead of the litmus test. There is no evidence that supports the method of auscultation and bubbling to confirm correct NG tube placement in the absence of aspirate. Radiology remains the 'gold standard' for checking correct NG tube placement. The revised method of NG tube placement and workflow was incorporated in the revised Standard Operating Procedures. A total of 17 roadshows were conducted to create awareness regarding the new method amongst the nurses, and the implementation of the revised method and workflow was commenced on 3 November 2008. The initial audit conducted 1 month after the

  6. Bilateral Pneumothoraces in a Trauma Patient After Dobhoff Tube Insertion.

    PubMed

    Abidali, Ali; Mangram, Alicia; Shirah, Gina R; Wilson, Whitney; Abidali, Ahmed; Moeser, Phillip; Dzandu, James K

    2018-03-05

    BACKGROUND Dobhoff tube insertion is a common procedure used in the clinical setting to deliver enteral nutrition. Although it is often viewed as an innocuous bedside procedure, there are risks for numerous complications such as tracheobronchial insertion, which could lead to deleterious consequences. We present to our knowledge the first reported case of bilateral pneumothoraces caused by the insertion of a Dobhoff tube. In addition, we also discuss common pitfalls for confirming the positioning of Dobhoff tubes, as well as risk factors that can predispose a patient to improper tube placement. CASE REPORT We present the case of a 74-year-old male patient with multiple orthopedic injuries following an auto-pedestrian collision. Five attempts were made to place a Dobhoff tube to maintain enteral nutrition. Follow-up abdominal x-ray revealed displacement of the Dobhoff tube in the left pleural space. After removal of the tube, a follow-up chest x-ray revealed iatrogenic bilateral pneumothoraces. Acute hypoxemic respiratory failure ensued; therefore, bilateral chest tubes were placed. Over the next three weeks, the patient's respiratory status improved and both chest tubes were removed. The patient was eventually discharged to a skilled nursing facility. CONCLUSIONS Improper placement of Dobhoff tubes can lead to rare complications such as bilateral pneumothoraces. This unique case report of bilateral pneumothoraces after Dobhoff tube placement emphasizes the necessity of using proper diagnostic techniques for verifying proper tube placement, as well as understanding the risk factors that predispose a patient to a malpositioned tube.

  7. Retrospective analysis of insulin responses to standard dosed oral glucose tests (OGTs) via naso-gastric tubing towards definition of an objective cut-off value.

    PubMed

    Warnken, Tobias; Delarocque, Julien; Schumacher, Svenja; Huber, Korinna; Feige, Karsten

    2018-01-19

    Insulin dysregulation (ID) with basal or postprandial hyperinsulinemia is one of the key findings in horses and ponies suffering from the equine metabolic syndrome (EMS). Assessment of ID can easily be performed in clinical settings by the use of oral glucose challenge tests. Oral glucose test (OGT) performed with 1 g/kg bodyweight (BW) glucose administered via naso-gastric tube allows the exact administration of a defined glucose dosage in a short time. However, reliable cut-off values have not been available so far. Therefore, the aim of the study was to describe variations in insulin response to OGT via naso-gastric tubing and to provide a clinical useful cut-off value for ID when using the insulin quantification performed with an equine-optimized insulin enzyme-linked immunosorbent assay. Data visualization revealed no clear separation in the serum insulin concentration of insulin sensitive and insulin dysregulated horses during OGT. Therefore, a model based clustering method was used to circumvent the use of an arbitrary limit for categorization. This method considered all data-points for the classification, taking into account the individual insulin trajectory during the OGT. With this method two clusters were differentiated, one with low and one with high insulin responses during OGT. The cluster of individuals with low insulin response was consistently detected, independently of the initialization parameters of the algorithm. In this cluster the 97.5% quantile of insulin is 110 µLU/mL at 120 min. We suggest using this insulin concentration of 110 µLU/mL as a cut-off value for samples obtained at 120 min in OGT. OGT performed with 1 g/kg BW glucose and administration via naso-gastric tubing can easily be performed under clinical settings. Application of the cut-off value of 110 µLU/mL at 120 min allows assessment of ID in horses.

  8. Learning nursing procedures: the influence of simulator fidelity and student gender on teaching effectiveness.

    PubMed

    Grady, Janet L; Kehrer, Rosemary G; Trusty, Carole E; Entin, Eileen B; Entin, Elliot E; Brunye, Tad T

    2008-09-01

    Simulation technologies are gaining widespread acceptance across a variety of educational domains and applications. The current research examines whether basic nursing procedure training with high-fidelity versus low-fidelity mannequins results in differential skill acquisition and perceptions of simulator utility. Fifty-two first-year students were taught nasogastric tube and indwelling urinary catheter insertion in one of two ways. The first group learned nasogastric tube and urinary catheter insertion using high-fidelity and low-fidelity mannequins, respectively, and the second group learned nasogastric tube and urinary catheter insertion using low-fidelity and high-fidelity mannequins, respectively. The dependent measures included student performance on nasogastric tube and urinary catheter insertion testing, as measured by observer-based instruments, and self-report questionnaires probing student attitudes about the use of simulation in nursing education. Results demonstrated higher performance with high-fidelity than with low-fidelity mannequin training. In response to a self-report posttraining questionnaire, participants expressed a more positive attitude toward the high-fidelity mannequin, especially regarding its responsiveness and realism.

  9. Rivaroxaban crushed tablet suspension characteristics and relative bioavailability in healthy adults when administered orally or via nasogastric tube.

    PubMed

    Moore, Kenneth T; Krook, Mark A; Vaidyanathan, Seema; Sarich, Troy C; Damaraju, C V; Fields, Larry E

    2014-07-01

    Because some patients have difficulty swallowing a whole tablet, we investigated the relative bioavailability of a crushed 20 mg rivaroxaban tablet and of 2 alternative crushed tablet dosing strategies. Stability and nasogastric (NG) tube adsorption characteristics of a crushed rivaroxaban tablet were assessed. Then, in 55 healthy adults, relative bioavailability of rivaroxaban administered orally as a whole tablet (Reference [Whole-Oral]), crushed tablet in applesauce suspension (Crushed-Oral), or crushed tablet in water suspension via NG tube (Crushed-NG) were determined. There were no significant changes in mean percent of non-degraded rivaroxaban recovered over 4 hours from crushed tablet suspensions (>98.4% recovery across all suspensions and time points) or after NG tube exposure (recovery: 99.1% for silicone and 98.9% for polyvinyl chloride NG tubes). Relative bioavailability was similar between Crushed-Oral and Reference dosing (Cmax and AUC∞ were within the 80-125% bioequivalence limits). Relative bioavailability was also similar between the Crushed-NG and Reference dosing (AUC∞ was within bioequivalence limits; Cmax [90% CI range: 78.5-85.8%] was only slightly below the 80% lower bioequivalence limit). A crushed rivaroxaban tablet was stable and when administered orally or via NG tube, displayed similar relative bioavailability compared to a whole tablet administered orally. © 2014, The American College of Clinical Pharmacology.

  10. Bilateral Pneumothoraces in a Trauma Patient After Dobhoff Tube Insertion

    PubMed Central

    Abidali, Ali; Mangram, Alicia; Shirah, Gina R.; Wilson, Whitney; Abidali, Ahmed; Moeser, Phillip; Dzandu, James K.

    2018-01-01

    Patient: Male, 74 Final Diagnosis: Pneumothorax Symptoms: Hypoxemia • shortness of breath Medication: — Clinical Procedure: — Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: Dobhoff tube insertion is a common procedure used in the clinical setting to deliver enteral nutrition. Although it is often viewed as an innocuous bedside procedure, there are risks for numerous complications such as tracheobronchial insertion, which could lead to deleterious consequences. We present to our knowledge the first reported case of bilateral pneumothoraces caused by the insertion of a Dobhoff tube. In addition, we also discuss common pitfalls for confirming the positioning of Dobhoff tubes, as well as risk factors that can predispose a patient to improper tube placement. Case Report: We present the case of a 74-year-old male patient with multiple orthopedic injuries following an auto-pedestrian collision. Five attempts were made to place a Dobhoff tube to maintain enteral nutrition. Follow-up abdominal x-ray revealed displacement of the Dobhoff tube in the left pleural space. After removal of the tube, a follow-up chest x-ray revealed iatrogenic bilateral pneumothoraces. Acute hypoxemic respiratory failure ensued; therefore, bilateral chest tubes were placed. Over the next three weeks, the patient’s respiratory status improved and both chest tubes were removed. The patient was eventually discharged to a skilled nursing facility. Conclusions: Improper placement of Dobhoff tubes can lead to rare complications such as bilateral pneumothoraces. This unique case report of bilateral pneumothoraces after Dobhoff tube placement emphasizes the necessity of using proper diagnostic techniques for verifying proper tube placement, as well as understanding the risk factors that predispose a patient to a malpositioned tube. PMID:29503437

  11. [Nasogastric tube feeding in bulimia. Controlled study with follow-up at 3 months].

    PubMed

    Rigaud, Daniel; Brayer, Véronique; Biton-Jélic, Violaine; Païs, Vanessa; Pennacchio, Hélène; Brun, Jean-Marcel

    2007-10-01

    Few effective treatments are available for severe forms of bulimia nervosa, which are accompanied by malnutrition, anxiety, and depressive mood. We previously showed in an open study that nasogastric tube feeding (TF) reduced binges and purging in patients with anorexia nervosa. This prospective randomized trial compared bulimia patients in two treatment groups: one group received TF at home, together with psychotherapy, nutritional counseling and a support group while the control group received only psychotherapy, nutritional counseling, and a support group. Patients in the first group underwent TF for 8 weeks (exclusively for 10 days and associated with meals thereafter). Assessment was based on clinical examination, laboratory results, and a variety of questionnaires (our in-house instrument for measuring binge and vomiting episodes, eating disorder inventory, Beck's depression inventory and the Hamilton rating scale for anxiety), all performed at the onset of treatment and at 8 days, 8 weeks (i.e., the end of TF), and 3 months after treatment began. Binges and vomiting disappeared faster and more frequently in TF patients than in the control group: 65% versus 29% (p<0.01). Three months later, these remained less frequent in the TF group than among controls (52% versus 33%, p=0.064). Nutritional status, depression, and anxiety improved more among the TF than control subjects (p<0.05). Tube feeding was effective in these patients with bulimia nervosa, reducing the number of binge and vomiting episodes and improving nutritional status and mood.

  12. Research on temperature control and influence of the vacuum tubes with inserted tubes solar heater

    NASA Astrophysics Data System (ADS)

    Xiao, L. X.; He, Y. T.; Hua, J. Q.

    2017-11-01

    A novel snake-shape vacuum tube with inserted tubes solar collector is designed in this paper, the heat transfer characteristics of the collector are analyzed according to its structural characteristics, and the influence of different working temperature on thermal characteristics of the collector is studied. The solar water heater prototype consisting of 14 vacuum tubes with inserted tubes is prepared, and the hot water storage control subsystem is designed by hysteresis comparison algorithm. The heat characteristic of the prototype was experimentally studied under hot water output temperature of 40-45°C, 50-55°C and 60-65°C. The daily thermal efficiency was 64%, 50% and 46%, respectively. The experimental results are basically consistent with the theoretical analysis.

  13. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    PubMed

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P < 0.05). Thirty min after needle withdrawal, the differences of the indices of cardiovascular function between the two groups were not significant (all P > 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  14. Tuberculous otitis media developing as a complication of tympanostomy tube insertion.

    PubMed

    Kim, Chang Woo; Jin, Jae Won; Rho, Young-Soo

    2007-03-01

    Primary tuberculous otitis media of which infection focus cannot be found elsewhere in the body is a rare disease. Route of the infection has been hypothesized as Eustachian tube or external auditory canal with tympanic membrane perforation but it is hard to ascertain in the patient. We present a case of an 8-year-old child who suffered chronic otorrhea after tympanostomy tube insertion. The radiological and histopathological findings revealed tuberculous otitis media, which occurred as a complication of tympanostomy tube insertion.

  15. Can insertion length for a double-lumen endobronchial tube be predicted?

    PubMed

    Dyer, R A; Heijke, S A; Russell, W J; Bloch, M B; James, M F

    2000-12-01

    It has been suggested that the appropriate length of insertion for double-lumen tubes can be estimated by external measurement. This study examined the accuracy of external measurement in estimating the actual length of insertion required in 130 patients. It also examined the relationship between the length inserted and the patient's height in 126 patients and their weight in 125 patients. Although there was a fair correlation between the measured external length and the final inserted length (r = 0.61), the 95% confidence intervals of slope and intercept allowed a large variation and the prediction was too wide to be clinically useful. Height was reasonably well correlated with the final length (r = 0.51) but an equally wide 95% confidence interval rendered it of little clinical value. There was no correlation between weight and final tube length. It is concluded that external measurement alone is not adequate to predict a clinically acceptable position of the double-lumen tube.

  16. The molecular characterisation of Escherichia coli K1 isolated from neonatal nasogastric feeding tubes.

    PubMed

    Alkeskas, Aldukali; Ogrodzki, Pauline; Saad, Mohamed; Masood, Naqash; Rhoma, Nasreddin R; Moore, Karen; Farbos, Audrey; Paszkiewicz, Konrad; Forsythe, Stephen

    2015-10-26

    The most common cause of Gram-negative bacterial neonatal meningitis is E. coli K1. It has a mortality rate of 10-15 %, and neurological sequelae in 30-50 % of cases. Infections can be attributable to nosocomial sources, however the pre-colonisation of enteral feeding tubes has not been considered as a specific risk factor. Thirty E. coli strains, which had been isolated in an earlier study, from the residual lumen liquid and biofilms of neonatal nasogastric feeding tubes were genotyped using pulsed-field gel electrophoresis, and 7-loci multilocus sequence typing. Potential pathogenicity and biofilm associated traits were determined using specific PCR probes, genome analysis, and in vitro tissue culture assays. The E. coli strains clustered into five pulsotypes, which were genotyped as sequence types (ST) 95, 73, 127, 394 and 2076 (Achman scheme). The extra-intestinal pathogenic E. coli (ExPEC) phylogenetic group B2 ST95 serotype O1:K1:NM strains had been isolated over a 2 week period from 11 neonates who were on different feeding regimes. The E. coli K1 ST95 strains encoded for various virulence traits associated with neonatal meningitis and extracellular matrix formation. These strains attached and invaded intestinal, and both human and rat brain cell lines, and persisted for 48 h in U937 macrophages. E. coli STs 73, 394 and 2076 also persisted in macrophages and invaded Caco-2 and human brain cells, but only ST394 invaded rat brain cells. E. coli ST127 was notable as it did not invade any cell lines. Routes by which E. coli K1 can be disseminated within a neonatal intensive care unit are uncertain, however the colonisation of neonatal enteral feeding tubes may be one reservoir source which could constitute a serious health risk to neonates following ingestion.

  17. Teaching project: a low-cost swine model for chest tube insertion training.

    PubMed

    Netto, Fernando Antonio Campelo Spencer; Sommer, Camila Garcia; Constantino, Michael de Mello; Cardoso, Michel; Cipriani, Raphael Flávio Fachini; Pereira, Renan Augusto

    2016-02-01

    to describe and evaluate the acceptance of a low-cost chest tube insertion porcine model in a medical education project in the southwest of Paraná, Brazil. we developed a low-cost and low technology porcine model for teaching chest tube insertion and used it in a teaching project. Medical trainees - students and residents - received theoretical instructions about the procedure and performed thoracic drainage in this porcine model. After performing the procedure, the participants filled a feedback questionnaire about the proposed experimental model. This study presents the model and analyzes the questionnaire responses. seventy-nine medical trainees used and evaluated the model. The anatomical correlation between the porcine model and human anatomy was considered high and averaged 8.1±1.0 among trainees. All study participants approved the low-cost porcine model for chest tube insertion. the presented low-cost porcine model for chest tube insertion training was feasible and had good acceptability among trainees. This model has potential use as a teaching tool in medical education.

  18. Effect of Probe Tube Insertion Depth on Spectral Measures of Speech

    PubMed Central

    Caldwell, Marc; Souza, Pamela E.; Tremblay, Kelly L.

    2006-01-01

    This study investigated how depth variations in the tip of the probe tube affected spectral measures of speech recorded in the external ear canal. Consonant-vowel nonsense syllables were recorded with a probe tube microphone system in 10 adult participants with normal middle ear function. Recordings were made with the probe tube tip placed 1 mm, 5 mm, and 10 mm beyond the medial tip of a custom earmold. The effect of probe depth was evaluated on spectral levels (one-third octave and one-twelfth octave band). Extending the probe tube 10 mm past the medial tip of the earmold gave the most accurate results, with relatively lower sound levels for either the 1-mm or 5-mm insertion depth. In general, the effect of insertion depth was minimal at frequencies below 3 to 4 kHz, although this varied with the specific phoneme and the width of the analysis bands. The authors found no significant difference between 1- and 5-mm insertion depths, suggesting that as long as the tip of the probe tube is sufficiently close to the tympanic membrane to capture the highest frequency of interest, it makes little difference if it is less than 5 mm beyond the earmold tip. PMID:16959735

  19. Alternative method for predicting optimal insertion depth of the laryngeal tube in children.

    PubMed

    Kim, J T; Jeon, S Y; Kim, C S; Kim, S D; Kim, H S

    2007-11-01

    Little information is available about the accuracy of the teeth mark on the laryngeal tube (LT) as a guide to correct placement in children. The aim of this crossover study was to evaluate three methods for optimal insertion depth of the size (#) 2 tube in children weighing 12-25 kg. In 24 children, the LT #2 was consecutively inserted by three different methods: (A) until the thick teeth mark on the tube was aligned with the upper incisors, (B) until resistance was felt, and (C) by inserting to a depth, previously measured, of the curved distance between the cricoid cartilage and the upper incisor. In each case, the depth of insertion, the degree of effective ventilation, the presence of leakage, and the fibreoptic view were assessed. Insertion based on the teeth mark led to a shorter insertion depth and a greater incidence of inadequate ventilation compared with the other two methods. There was no difference in the adequacy of ventilation between methods B and C. The vocal cords were more easily identified with methods B (62.5%) and C (75%) than with method A (12.5%). Insertion of the LT #2 aligned with the teeth mark can result in a shallow insertion depth and inadequate ventilation. The measured distance from the cricoid cartilage to the upper incisor offers alternative guidance for correct LT insertion.

  20. Relative bioavailability of single doses of prolonged-release tacrolimus administered as a suspension, orally or via a nasogastric tube, compared with intact capsules: a phase 1 study in healthy participants.

    PubMed

    Undre, Nasrullah; Dickinson, James

    2017-04-04

    Tacrolimus, an immunosuppressant widely used in solid organ transplantation, is available as a prolonged-release capsule for once-daily oral administration. In the immediate postsurgical period, if patients cannot take intact capsules orally, tacrolimus therapy is often initiated as a suspension of the capsule contents, delivered orally or via a nasogastric tube. This study evaluated the relative bioavailability of prolonged-release tacrolimus suspension versus intact capsules in healthy participants. A phase 1, open-label, single-dose, cross-over study. A single clinical research unit. In total, 20 male participants, 18-55 years old, entered and completed the study. All participants received nasogastric administration of tacrolimus 10 mg suspension in treatment period 1, with randomisation to oral administration of suspension or intact capsules in periods 2 and 3. Blood concentration-time profile over 144 hours was used to estimate pharmacokinetic parameters. Primary end point: relative bioavailability of prolonged-release intact capsule versus oral or nasogastric administration of prolonged-release tacrolimus suspension (area under the concentration-time curve (AUC) from time 0 to infinity post-tacrolimus dose (AUC 0-∞ ); AUC measured until the last quantifiable concentration (AUC 0-tz ); maximum observed concentration (C max ); time to C max (T max )). Tolerability was assessed throughout the study. Relative bioavailability of prolonged-release tacrolimus suspension administered orally was similar to intact capsules, with a ratio of least-square means for AUC 0-tz and AUC 0-∞ of 1.05 (90% CI 0.96 to 1.14). Bioavailability was lower with suspension administered via a nasogastric tube versus intact capsules (17%; ratio 0.83; CI 0.76 to 0.92). C max was higher for oral and nasogastric suspension (30% and 28%, respectively), and median T max was shorter (difference 1.0 and 1.5 hours postdose, respectively) versus intact capsules (2.0 hours). Single 10

  1. Current microbiology of percutaneous endoscopic gastrostomy tube (PEG tube) insertion site infections in patients with cancer.

    PubMed

    Rolston, Kenneth V I; Mihu, Coralia; Tarrand, Jeffrey J

    2011-08-01

    Percutaneous endoscopic gastrostomy (PEG) is frequently used to provide enteral access in cancer patients who are unable to swallow. Infection is an important complication in this setting. Current microbiological data are needed to guide infection prevention and treatment strategies. The microbiological records of our institution (a 550-bed comprehensive cancer center) were retrospectively reviewed over an 8-month study period in order to identify patients who developed PEG tube insertion site infections, and review their microbiological details and susceptibility/resistance data. Fifty-eight episodes of PEG tube insertion site infections were identified. Of these, 31 (53%) were monomicrobial, and the rest were polymicrobial. The most common organisms isolated were Candida species, Staphylococcus aureus, and Pseudomonas aeruginosa. All infections were local (cellulitis, complicated skin, and skin structure infections including abdominal wall abscess) with no cases of concomitant bacteremia being documented. Most of the organisms isolated were susceptible to commonly used antimicrobial agents, although some quinolone-resistant and some multidrug-resistant organisms were isolated. This retrospective study provides descriptive data regarding PEG tube insertion site infections. These data have helped us update institutional guidelines for infection prevention and treatment as part of our focus on antimicrobial stewardship.

  2. Enhanced heat transfer and frictional losses in heat exchanger tube with modified helical coiled inserts

    NASA Astrophysics Data System (ADS)

    Verma, Aditya; Kumar, Manoj; Patil, Anil Kumar

    2018-04-01

    The application of compact heat exchangers in any thermal system improves overall performance with a considerable reduction in size and weight. Inserts of different geometrical features have been used as turbulence promoting devices to increase the heat transfer rates. The present study deals with the experimental investigation of heat transfer and fluid flow characteristics of a tubular heat exchanger fitted with modified helical coiled inserts. Experiments have been carried out for a smooth tube without insert, tube fitted with helical coiled inserts, and modified helical coiled inserts. The helical coiled inserts are tested by varying the pitch ratio and wire diameter ratio from 0.5-1.5, and 0.063-0.125, respectively for the Reynolds number range of 1400 to 11,000. Experimental data have also been collected for the modified helical coiled inserts with gradually increasing pitch (GIP) and gradually decreasing pitch (GDP) configurations. The Nusselt number and friction factor values for helical coiled inserts are enhanced in the range of 1.42-2.62, 3.4-27.4, relative to smooth tube, respectively. The modified helical coiled insert showed enhancements in Nusselt number and friction factor values in the range of 1.49-3.14, 11.2-19.9, relative to smooth tube, respectively. The helical coiled and modified helical coiled inserts have thermo-hydraulic performance factor in the range of 0.59-1.29, 0.6-1.39, respectively. The empirical correlations of Nusselt number and friction factor for helical coiled inserts are proposed.

  3. Is nasogastric tube drainage required after reconstructive surgery for neurogenic bladder dysfunction?

    PubMed

    Erickson, Bradley A; Dorin, Ryan P; Clemens, J Quentin

    2007-05-01

    To determine whether the routine use of nasogastric tubes (NGTs) after bowel surgery for neurogenic bladder dysfunction improves outcomes. We retrospectively evaluated 54 consecutive patients (30 women, 24 men) with neurogenic bladder who underwent bladder reconstruction or replacement with bowel segments by one surgeon from December 2000 to August 2005. The first 32 [NGT(+)] had NGTs placed during the procedure, whereas the subsequent 22 [NGT(-)] did not. We compared short-term postoperative outcomes between groups. Patient age ranged from 17 to 74 years (mean, 42.6 years). Procedures included augmentation cystoplasty with or without creation of catheterizable stoma (31), ileovesicostomy (13), and ileal conduit (9). Mean age or mean operative time did not differ between the NGT(+) and NGT(-) groups. The NGT(-) patients experienced less time to oral intake (3.1 versus 4.4 days, P <0.01), fewer days to flatus (2.9 versus 4.0 days, P = 0.01), and fewer days to first bowel movement (4.4 versus 5.9 days, P = 0.01). We found no statistical differences in the incidence of postoperative complications. Overall hospital days were less in the NGT(-) patients, but this did not reach statistical significance (9.9 versus 11.0, P = 0.2). Routine use of NGTs in patients undergoing bladder reconstruction or replacement for neurogenic bladder dysfunction seems to confer no benefit. The omission of NGTs in this population is possible without increasing overall morbidity. These findings parallel those previously reported in neurologically intact patients undergoing urinary diversion.

  4. A Comparative Analysis of Nasogastric and Intravenous Fluid Resuscitation in Patients with Malignant Obstructive Jaundice Prior to Endoscopic Biliary Drainage

    PubMed Central

    Baghel, Kavita; Raj, Saloni; Awasthi, Induja; Gupta, Vishal; Chandra, Abhijit; Srivastava, Rajeshwar Nath

    2013-01-01

    Background: An alternative to intravenous is nasogastric fluid administration through normal functioning gut. Though not common, this practice has significance in mass causalities and elective situations. Aim: The study was designed to compare nasogastric and intravenous fluid resuscitation in malignant obstructive jaundice (OJ) and their effect on endotoxemia. Materials and Methods: Sixty patients with malignant OJ undergoing endoscopic biliary drainage were randomized into two groups. A total of 4 l of fluid (Ringer's lactate) was administered to Group A through nasogastric tube and to Group B through intravenous route for 48 h. Vital parameters, serum bilirubin, serum creatinine, creatinine clearance rate, electrolytes, and endotoxemia were monitored. Results: Significant improvement in blood pressure (Group A, P = 0.014; Group B, P = 0.020) and significant decrease in serum bilirubin level (Group A, P = 0.001; Group B, P > 0.0001) was observed in both groups after resuscitation. Significantly decreased (P = 0.036) post hydration endotoxin level was observed in Group A as compared to Group B. Febrile events were significantly higher (P = 0.023) in Group B as compared to Group A (6 vs 0). Electrolyte abnormalities were found more in Group B, however statistically insignificant. Conclusion: In OJ patient undergoing biliary drainage, preoperative fluid resuscitation through nasogastric tube may be helpful in reducing postoperative septic complications and endotoxemia. PMID:24251269

  5. Evaluation of crushed ticagrelor tablet doses: recovery following crushing and naso-gastric tube passage ex vivo.

    PubMed

    Crean, Barry; Finnie, Cindy; Crosby, Anna

    2013-06-01

    Orally available ticagrelor in combination with low-dose aspirin (75-100 mg/day) is indicated for adult patients with acute coronary syndromes. However, patients with swallowing difficulties may be unable to consume the currently available 90-mg tablet. It is hypothesized that ticagrelor could be given to this patient cohort as a crushed dose administered either orally or via a naso-gastric (NG) tube. To investigate the potential use of crushed ticagrelor tablets (90- and 180-mg doses) for oral dose or NG tube administration. Ticagrelor tablets (90 or 180 mg [two 90-mg tablets]) were prepared to emulate oral and NG tube administration by similar methods. For the oral dose, ticagrelor tablets were crushed using a mortar and pestle and transferred to a dosing cup. 100 mL of water was added to the mortar, stirred, and the contents were transferred to the dosing cup and stirred to form a suspension. At this stage, where the suspension would normally be administered to a patient, it was collected for high performance liquid chromatography (HPLC) analysis. The mortar was then flushed with 100 mL of water, and the contents were again transferred to the dosing cup, stirred, and collected for HPLC analysis. For the NG dose, polyvinylchloride, polyurethane, and silicone size CH10 NG tubes were used. The tablets were crushed using a mortar and pestle, diluted with 50 mL of water, and stirred. At this stage, where the suspension would normally be administered to a patient through an NG tube using a syringe, it was collected for HPLC analysis. The mortar was then flushed with two additional 50 mL aliquots of water and the contents were passed through the NG tube. HPLC analysis examined the recoverability of ticagrelor in each of the dose suspensions and flushes and the stability of the suspension when held in a syringe for up to 2 h. One or two crushed 90-mg ticagrelor tablets, prepared for either oral or NG tube administration, delivers a mean dose of ≥97% of the original

  6. Percutaneous endoscopic gastrostomy versus nasogastric tube feeding for patients with head and neck cancer: a systematic review

    PubMed Central

    Wang, Jinfeng; Liu, Minjie; Liu, Chao; Ye, Yun; Huang, Guanhong

    2014-01-01

    There are two main enteral feeding strategies—namely nasogastric (NG) tube feeding and percutaneous gastrostomy—used to improve the nutritional status of patients with head and neck cancer (HNC). But up till now there has been no consistent evidence about which method of enteral feeding is the optimal method for this patient group. To compare the effectiveness of percutaneous gastrostomy and NGT feeding in patients with HNC, relevant literature was identified through Medline, Embase, Pubmed, Cochrane, Wiley and manual searches. We included randomized controlled trials (RCTs) and non-experimental studies comparing percutaneous gastrostomy—including percutaneous endoscopic gastrostomy (PEG) and percutaneous fluoroscopic gastrostomy (PFG) —with NG for HNC patients. Data extraction recorded characteristics of intervention, type of study and factors that contributed to the methodological quality of the individual studies. Data were then compared with respect to nutritional status, duration of feeding, complications, radiotherapy delays, disease-free survival and overall survival. Methodological quality of RCTs and non-experimental studies were assessed with separate standard grading scales. It became apparent from our studies that both feeding strategies have advantages and disadvantages. PMID:24453356

  7. Percutaneous endoscopic gastrostomy versus nasogastric tube feeding for patients with head and neck cancer: a systematic review.

    PubMed

    Wang, Jinfeng; Liu, Minjie; Liu, Chao; Ye, Yun; Huang, Guanhong

    2014-05-01

    There are two main enteral feeding strategies-namely nasogastric (NG) tube feeding and percutaneous gastrostomy-used to improve the nutritional status of patients with head and neck cancer (HNC). But up till now there has been no consistent evidence about which method of enteral feeding is the optimal method for this patient group. To compare the effectiveness of percutaneous gastrostomy and NGT feeding in patients with HNC, relevant literature was identified through Medline, Embase, Pubmed, Cochrane, Wiley and manual searches. We included randomized controlled trials (RCTs) and non-experimental studies comparing percutaneous gastrostomy-including percutaneous endoscopic gastrostomy (PEG) and percutaneous fluoroscopic gastrostomy (PFG) -with NG for HNC patients. Data extraction recorded characteristics of intervention, type of study and factors that contributed to the methodological quality of the individual studies. Data were then compared with respect to nutritional status, duration of feeding, complications, radiotherapy delays, disease-free survival and overall survival. Methodological quality of RCTs and non-experimental studies were assessed with separate standard grading scales. It became apparent from our studies that both feeding strategies have advantages and disadvantages.

  8. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    PubMed

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  9. [Polytrauma with tension pneumothorax with inserted chest tube].

    PubMed

    Genzwürker, H V; Volz, A; Isselhorst, C; Gieser, R; Neufang, T; Roth, H; Birmelin, M; Kerger, H

    2005-12-01

    The authors report a case of a 25-year-old woman with a polytrauma, caused by a free fall of 12 metres in suicidal intention. Following endotracheal intubation and mechanical ventilation by an emergency physician at the scene, the patient was delivered to the emergency room of an university hospital. An ultrasonic check of the abdomen revealed free fluid in the abdominal cavity, and a rupture of liver and spleen was suspected. Since breath sounds over the right lung were diminished, a chest tube was inserted immediately in the fifth intercostal space in the anterior axillary line. About 300 millilitres of blood were drained by the tube. Shortly thereafter, a laparotomy was performed, where spleen and liver rupture were confirmed and treated. After 60 minutes, the patient developed severe hypotension coupled with ventricular tachycardia and fibrillation, and resuscitation measures had to be initiated. Since breath sounds over the right lung were missing, a tension pneumothorax was suspected and a thoracotomy performed immediately. While huge amounts of air and blood were emerging from the thoracic cavity, a rupture of the right mainstem bronchus as well as of the right pulmonary artery and vena subclavia was identified. The chest tube was found dislocated into the subcutaneous tissue. Despite of open heart compression, application of adrenaline and noradrenaline and substitution of packed red blood cells and of crystalloid and colloid solutions, all resuscitation measures failed so that the patient died shortly after on the operation table. This case illustrates first the difficulties of an adequate thoracic trauma management, particularly, when clinical symptoms are discrete, second the problems of the insertion and control of a chest tube, and third risks associated with wrong position or secondary dislocation which may include - as in our case - "masking" of severe injury patterns and delay of life-saving measures such as an immediate thoracotomy. In order to

  10. Experiment attributes to establish tube with twisted tape insert performance cooling plasma facing components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, Emily; Ramirez, Emilio; Ruggles, Art E.

    The modeling capability for tubes with twisted tape inserts is reviewed with reference to the application of cooling plasma facing components in magnetic confinement fusion devices. The history of experiments examining the cooling performance of tubes with twisted tape inserts is reviewed with emphasis on the manner of heating, flow stability limits and the details of the test section and fluid delivery system. Models for heat transfer, burnout, and onset of net vapor generation in straight tube flows and tube with twisted tape are compared. As a result, the gaps in knowledge required to establish performance limits of the plasmamore » facing components are identified and attributes of an experiment to close those gaps are presented.« less

  11. Experiment attributes to establish tube with twisted tape insert performance cooling plasma facing components

    DOE PAGES

    Clark, Emily; Ramirez, Emilio; Ruggles, Art E.; ...

    2015-08-18

    The modeling capability for tubes with twisted tape inserts is reviewed with reference to the application of cooling plasma facing components in magnetic confinement fusion devices. The history of experiments examining the cooling performance of tubes with twisted tape inserts is reviewed with emphasis on the manner of heating, flow stability limits and the details of the test section and fluid delivery system. Models for heat transfer, burnout, and onset of net vapor generation in straight tube flows and tube with twisted tape are compared. As a result, the gaps in knowledge required to establish performance limits of the plasmamore » facing components are identified and attributes of an experiment to close those gaps are presented.« less

  12. J-tube technique for double-j stent insertion during laparoscopic upper urinary tract surgical procedures.

    PubMed

    Kim, Hyung Suk; Lee, Byung Ki; Jung, Jin-Woo; Lee, Jung Keun; Byun, Seok-Soo; Lee, Sang Eun; Jeong, Chang Wook

    2014-11-01

    Double-J stent insertion has been generally performed during laparoscopic upper urinary tract (UUT) surgical procedures to prevent transient urinary tract obstruction and postoperative flank pain from ureteral edema and blood clots. Several restrictive conditions that make this procedure difficult and time consuming, however, include the coiled distal ends of the flexible Double-J stent and the limited bending angle of the laparoscopic instruments. To overcome these limitations, we devised a Double-J stent insertion method using the new J-tube technique. Between July 2011 and May 2013, Double-J stents were inserted using the J-tube technique in 33 patients who underwent a laparoscopic UUT surgical procedure by a single surgeon. The mean stent placement time was 4.8±2.7 minutes, and there were no intraoperative complications. In conclusion, the J-tube technique is a safe and time-saving method for Double-J stent insertion during laparoscopic surgical procedures.

  13. A case report of esophageal perforation: Complication of nasogastric tube placement

    PubMed Central

    Isik, Arda; Firat, Deniz; Peker, Kemal; Sayar, Ilyas; Idiz, Oguz; Soytürk, Mehmet

    2014-01-01

    Patient: Male, 70 Final Diagnosis: Esophageal perforation Symptoms: Abdominal pain • nausea • vomiting Medication: — Clinical Procedure: — Specialty: Surgery Objective: Unusual clinical course Background: Esophageal perforation is a well-defined and severe clinical condition. There are several etiologies of esophagus perforation. Case Report: We report the case of a 70-year-old Caucasian man who underwent an emergency cholecystectomy due to acute cholecystitis. Two days after surgery, his condition deteriorated. Thorax computerized tomography revealed an esophageal perforation. Conclusions: Esophageal perforation due to nasogastric application is relatively rare but the consequences are potentially serious. The anatomy of the upper gastrointestinal system should be understood by all healthcare professionals involved in the treatment. PMID:24803977

  14. Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes.

    PubMed

    Eslami, Yadolla; Mohammadi, Massood; Fakhraie, Ghasem; Zarei, Reza; Moghimi, Sasan

    2014-02-01

    To report the efficacy and safety of Ahmed glaucoma valve (AGV) insertion into the ciliary sulcus in pseudophakic/aphakic patients. A chart review was done on patients with uncontrolled glaucoma, who underwent AGV implantation with tube inserted into the ciliary sulcus. Baseline intraocular pressure (IOP) and number of medications were compared with that of postoperative follow-up visits. Surgical success was defined as last IOP <21 mm Hg and 20% reduction in IOP, without further surgery for complications or glaucoma control, and without loss of light perception. Postoperative complications were recorded. Twenty-three eyes of 23 patients were recruited with the mean follow-up of 9 months (range, 3 to 24 mo). The mean (SD) age of patients was 49.9 (16.9) years (range, 22 to 80 years). The mean (SD) IOP (mm Hg) was reduced from 37.9 (12.4) before surgery to 16.2 (3.6) at the last follow-up visit (P<0.001). The mean (SD) number of medications was reduced from 3.3 (0.9) preoperatively to 1 (1.1) at the last follow-up (P<0.001). Success rate was 18/23 (78.6%). Complications included endophthalmitis in 1 eye, tube exposure in 1 diabetic patient, and vitreous tube occlusion in 1 eye. No case of corneal decompensation or graft failure was seen during follow-up. Ciliary sulcus placement of the tube of AGV effectively reduces IOP and medication use in short term. It has the potential to lower corneal complications of anterior chamber tube insertion and avoids the need for pars plana vitrectomy and tube insertion in patients at higher risk of corneal decompensation.

  15. Age as a Determinant to Select an Anesthesia Method for Tympanostomy Tube Insertion in a Pediatric Population

    PubMed Central

    Jung, Kihwan; Kim, Hojong

    2015-01-01

    Background and Objectives To evaluate the relationship between age and anesthesia method used for tympanostomy tube insertion (TTI) and to provide evidence to guide the selection of an appropriate anesthesia method in children. Subjects and Methods We performed a retrospective review of children under 15 years of age who underwent tympanostomy tube insertion (n=159) or myringotomy alone (n=175) under local or general anesthesia by a single surgeon at a university-based, secondary care referral hospital. Epidermiologic data between local and general anesthesia groups as well as between TTI and myringotomy were analyzed. Medical costs were compared between local and general anesthesia groups. Results Children who received local anesthesia were significantly older than those who received general anesthesia. Unilateral tympanostomy tube insertion was performed more frequently under local anesthesia than bilateral. Logistic regression modeling showed that local anesthesia was more frequently applied in older children (odds ratio=1.041) and for unilateral tympanostomy tube insertion (odds ratio=8.990). The cut-off value of age for local anesthesia was roughly 5 years. Conclusions In a pediatric population at a single medical center, age and whether unilateral or bilateral procedures were required were important factors in selecting an anesthesia method for tympanostomy tube insertion. Our findings suggest that local anesthesia can be preferentially considered for children 5 years of age or older, especially in those with unilateral otitis media with effusion. PMID:26185791

  16. Factors related to persisting perforations after ventilation tube insertion.

    PubMed

    O'Connell Ferster, Ashley P; Tanner, April Michelle; Karikari, Kodjo; Roberts, Christopher; Wiltz, Derek; Carr, Michele M

    2016-02-01

    Over a million ventilation tubes are placed annually in the United States, making this one of the most commonly performed procedures in the field of medicine. Certain factors increase the risk of persistent tympanic membrane perforation following the extrusion of short term ventilation tubes. Persistent perforations may fail to heal on their own, necessitating surgical closure to avoid conductive hearing loss. It is important to detect factors that may predict children who are at increased risk for persistent perforations. This study was a retrospective chart review that involved 757 patients between 2003 and 2008. The patients studied were within the age of 2 months-17 years, and all had short term tubes placed. The chart data also included demographic information, comorbidities, and information related to tube insertion and follow-up care. Chi-square, t-test, and multivariate logistic regression were conducted to compare variables between patients with perforations and those without. Data from 757 patients was analyzed, showing that perforation rate is associated with rhinorrhea, operative tube removal, aural polyps, and otorrhea (OR 1.72, 8.16, 4.69, and 1.72 respectively). The absence of otorrhea decreased the likelihood of TM perforations and no significant differences were found in gender, total number of sets of tubes, type of tube, use of nasal steroids, adenoidectomy, or nasal congestion. Our findings suggest that children with rhinorrhea, otorrhea, aural polyps, or prolonged intubation requiring operative tube removal should be identified clinically as children at risk of persisting perforation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. SVC obstruction and stridor relieved by nasogastric tube insertion

    PubMed Central

    Molena, Emma J.; Krishnamoorthy, Ashwin; Praveen, Coimbatore

    2016-01-01

    Achalasia is an idiopathic motility disorder of the oesophagus of increasing incidence. It is characterized by aperistalsis of the lower oesophagus and failure of relaxation of the lower oesophageal sphincter. Patients classically present with chronic symptoms of dysphagia, chest pain, weight loss and regurgitation, and they commonly suffer pulmonary complications such as recurrent microaspiration of static, retained food contents of the upper oesophagus. However, it has also been described, uncommonly, to present with megaoesophagus and secondary tracheal compression. We present a case of megaoesophagus secondary to achalasia which presented with stridor and signs of acute superior vena caval obstruction. PMID:26933001

  18. SVC obstruction and stridor relieved by nasogastric tube insertion.

    PubMed

    Molena, Emma J; Krishnamoorthy, Ashwin; Praveen, Coimbatore

    2016-03-01

    Achalasia is an idiopathic motility disorder of the oesophagus of increasing incidence. It is characterized by aperistalsis of the lower oesophagus and failure of relaxation of the lower oesophageal sphincter. Patients classically present with chronic symptoms of dysphagia, chest pain, weight loss and regurgitation, and they commonly suffer pulmonary complications such as recurrent microaspiration of static, retained food contents of the upper oesophagus. However, it has also been described, uncommonly, to present with megaoesophagus and secondary tracheal compression. We present a case of megaoesophagus secondary to achalasia which presented with stridor and signs of acute superior vena caval obstruction. Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2016.

  19. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

    PubMed

    Sitzwohl, Christian; Langheinrich, Angelika; Schober, Andreas; Krafft, Peter; Sessler, Daniel I; Herkner, Harald; Gonano, Christopher; Weinstabl, Christian; Kettner, Stephan C

    2010-11-09

    To determine which bedside method of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity. Prospective randomised blinded study. Department of anaesthesia in tertiary academic hospital. 160 consecutive patients (American Society of Anesthesiologists category I or II) aged 19-75 scheduled for elective gynaecological or urological surgery. Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube was fibreoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. To determine whether the tube was properly positioned in the trachea, in each patient first year residents and experienced anaesthetists were randomly assigned to independently perform bilateral auscultation of the chest (auscultation); observation and palpation of symmetrical chest movements (observation); estimation of the position of the tube by the insertion depth (tube depth); or a combination of all three (all three). Correct and incorrect judgments of endotracheal tube position. 160 patients underwent 320 observations by experienced and inexperienced anaesthetists. First year residents missed endobronchial intubation by auscultation in 55% of cases and performed significantly worse than experienced anaesthetists with this bedside test (odds ratio 10.0, 95% confidence interval 1.4 to 434). With a sensitivity of 88% (95% confidence interval 75% to 100%) and 100%, respectively, tube depth and the three tests combined were significantly more sensitive for detecting endobronchial intubation than auscultation (65%, 49% to 81%) or observation(43%, 25% to 60%) (P<0.001). The four tested methods had the same specificity for ruling out endobronchial intubation (that is, confirming correct tracheal intubation). The average correct tube insertion depth was

  20. Experimental and numerical investigation on heat transfer augmentation in a circular tube under forced convection with annular differential blockages/inserts

    NASA Astrophysics Data System (ADS)

    Waghole, D. R.

    2018-06-01

    Investigation on heat transfer by generating turbulence in the fluid stream inside the circular tube is an innovative area of research for researchers. Hence, many techniques are been investigated and adopted for enhancement of heat transfer rate to reduce the size and the cost of the heat exchanger/circular tube. In the present study the effect of differential solid ring inserts /turbulators on heat transfer, friction factor of heat exchanger/circular tube was evaluated through experimentally and numerically. The experiments were conducted in range of 3000 ≤Re≤ 6500 and annular blockages 0 ≤ɸ≤50 %. The heat transfer rate was higher for differential combination of inserts as compared to tube fitted with uniform inserts. The maximum heat transfer was obtained by the use of differential metal circular ring inserts/blockages. From this study, Nusselt number, friction factor and enhancement factor are found as 2.5-3.5 times, 12% - 50.5% and 155% - 195%, respectively with water. Finally new possible correlations for predicting heat transfer and friction factor in the flow of water through the circular tube with differential blockages/inserts are proposed.

  1. Nasogastric Hydration in Infants with Bronchiolitis Less Than 2 Months of Age.

    PubMed

    Oakley, Ed; Bata, Sonny; Rengasamy, Sharmila; Krieser, David; Cheek, John; Jachno, Kim; Babl, Franz E

    2016-11-01

    To determine whether nasogastric hydration can be used in infants less than 2 months of age with bronchiolitis, and characterize the adverse events profile of these infants compared with infants given intravenous (IV) fluid hydration. A descriptive retrospective cohort study of children with bronchiolitis under 2 months of age admitted for hydration at 3 centers over 3 bronchiolitis seasons was done. We determined type of hydration (nasogastric vs IV fluid hydration) and adverse events, intensive care unit admission, and respiratory support. Of 491 infants under 2 months of age admitted with bronchiolitis, 211 (43%) received nonoral hydration: 146 (69%) via nasogastric hydration and 65 (31%) via IV fluid hydration. Adverse events occurred in 27.4% (nasogastric hydration) and 23.1% (IV fluid hydration), difference of 4.3%; 95%CI (-8.2 to 16.9), P = .51. The majority of adverse events were desaturations (21.9% nasogastric hydration vs 21.5% IV fluid hydration, difference 0.4%; [-11.7 to 12.4], P = .95). There were no pulmonary aspirations in either group. Apneas and bradycardias were similar in each group. IV fluid hydration use was positively associated with intensive care unit admission (38.5% IV fluid hydration vs 19.9% nasogastric hydration; difference 18.6%, [5.1-32.1], P = .004); and use of ventilation support (27.7% IV fluid hydration vs 15.1% nasogastric hydration; difference 12.6 [0.3-23], P = .03). Fewer infants changed from nasogastric hydration to IV fluid hydration than from IV fluid hydration to nasogastric hydration (12.3% vs 47.7%; difference -35.4% [-49 to -22], P < .001). Nasogastric hydration can be used in the majority of young infants admitted with bronchiolitis. Nasogastric hydration and IV fluid hydration had similar rates of complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial

    PubMed Central

    Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-01-01

    Background The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. Objective The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). Methods In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module “Thoracocentesis” discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants’ performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here

  3. Stability and recovery of DIFICID(®) (Fidaxomicin) 200-mg crushed tablet preparations from three delivery vehicles, and administration of an aqueous dispersion via nasogastric tube.

    PubMed

    Tousseeva, Anna; Jackson, J Derek; Redell, Mark; Henry, Teresa; Hui, Michael; Capurso, Shelley; DeRyke, C Andrew

    2014-12-01

    Fidaxomicin is approved for the treatment of adults with Clostridium difficile-associated diarrhea, many of whom have difficulty swallowing an intact tablet. The study objective was to evaluate the stability and recovery of crushed DIFICID(®) (fidaxomicin) 200-mg tablets dispersed in water, applesauce, or Ensure(®) brand liquid nutritional supplement, and to determine the recovery of fidaxomicin from the administration of an aqueous dispersion of a crushed DIFICID(®) tablet through a nasogastric (NG) tube. DIFICID(®) tablets were crushed and dispersed in water, applesauce, or Ensure(®). The stability and recovery of fidaxomicin were evaluated over 24 h in these vehicles. In a separate experiment, the ability to recover a full dose of fidaxomicin when administering as an aqueous dispersion through an NG tube was assessed. When DIFICID(®) tablets were crushed and dispersed in water, the active ingredient, fidaxomicin, was stable for up to 2 h at room temperature. Additionally, it was stable for up to 24 h in dispersions with applesauce or Ensure(®). Recovery of fidaxomicin after crushing and dispersing in any of the three vehicles studied ranged from 95 to 108 %, which is within the normal range of individual tablet variability. When crushed, dispersed in water, and administered through an NG tube, the average recovery of fidaxomicin was 96 %. Stability and recovery of fidaxomicin were confirmed when DIFICID(®) tablets were crushed and dispersed in water, applesauce, or Ensure(®). In addition, administration of an aqueous dispersion of a crushed tablet through an NG tube is supported by acceptable recovery of fidaxomicin.

  4. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial.

    PubMed

    Haubruck, Patrick; Nickel, Felix; Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-05-21

    The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module "Thoracocentesis" discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants' performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here, trainees gave information about their

  5. PEG tube insertion -- discharge

    MedlinePlus

    ... be treated with medicine. Caring for the PEG-tube Site Drainage from around the PEG tube is common for the first 1 or 2 ... cotton swab or gauze. Try to remove any drainage or crusting on the skin and tube. Be gentle. If you used soap, gently clean ...

  6. Heat transfer and pressure drop studies of TiO2/DI water nanofluids in helically corrugated tubes using spiraled rod inserts

    NASA Astrophysics Data System (ADS)

    Anbu, S.; Venkatachalapathy, S.; Suresh, S.

    2018-05-01

    An experimental study on the convective heat transfer and friction factor characteristics of TiO2/DI water nanofluids in uniformly heated plain and helically corrugated tubes (HCT) with and without spiraled rod inserts (SRI) under laminar flow regime is presented in this paper. TiO2 nanoparticles with an average size of 32 nm are dispersed in deionized (DI) water to form stable suspensions containing 0.1, 0.15, 0.2, and 0.25% volume concentrations of nanoparticles. It is found that the inclusion of nanoparticles to DI water ameliorated Nusselt number which increased with nanoparticles concentration upto 0.2%. Two spiraled rod inserts made of copper with different pitches (pi = 50 mm and 30 mm) are inserted in both plain and corrugated tubes and it is found that the addition of these inserts increased the Nusselt number substantially. For Helically corrugated tube with lower pitch and maximum height of corrugation (pc = 8 mm, hc = 1 mm) with 0.2% volume concentration of nanoparticles, a maximum enhancement of 15% in Nusselt number is found without insert and with insert having lower pitch (pi = 30 mm) the enhancement is 34% when compared to DI water in plain tube. The results on friction factor show a maximum penalty of about 53.56% for the above HCT.

  7. Reduction of frequent otitis media and pressure-equalizing tube insertions in children after introduction of pneumococcal conjugate vaccine.

    PubMed

    Poehling, Katherine A; Szilagyi, Peter G; Grijalva, Carlos G; Martin, Stacey W; LaFleur, Bonnie; Mitchel, Ed; Barth, Richard D; Nuorti, J Pekka; Griffin, Marie R

    2007-04-01

    Streptococcus pneumoniae is an important cause of otitis media in children. In this study we estimated the effect of routine childhood immunization with heptavalent pneumococcal conjugate vaccine on frequent otitis media (3 episodes in 6 months or 4 episodes in 1 year) and pressure-equalizing tube insertions. The study population included all children who were enrolled at birth in TennCare or selected upstate New York commercial insurance plans as of July 1998 and continuously followed until 5 years old, loss of health plan enrollment, study outcome, or end of the study. We compared the risk of developing frequent otitis media or having pressure-equalizing tube insertion for 4 birth cohorts (1998-1999, 1999-2000, 2000-2001, and 2001-2002) by using Cox regression analysis. We used data from the National Immunization Survey to estimate the heptavalent pneumococcal conjugate vaccine uptake for children in these 4 birth cohorts in Tennessee and New York. The proportion of children in Tennessee and New York who received at least 3 doses of heptavalent pneumococcal conjugate vaccine by 2 years of age increased from < or = 1% for the 1998-1999 birth cohort to approximately 75% for the 2000-2001 birth cohort. By age 2 years, 29% of Tennessee and New York children born in 2000-2001 had developed frequent otitis media, and 6% of each of these birth cohorts had pressure-equalizing tubes inserted. Comparing the 2000-2001 birth cohort to the 1998-1999 birth cohort, frequent otitis media declined by 17% and 28%, and pressure-equalizing tube insertions declined by 16% and 23% for Tennessee and New York children, respectively. For the 2000-2001 to the 2001-2002 birth cohort, frequent otitis media and pressure-equalizing tubes remained stable in New York but increased in Tennessee. After heptavalent pneumococcal conjugate vaccine introduction, children were less likely to develop frequent otitis media or have pressure-equalizing tube insertions.

  8. Gastric phytobezoars may be treated by nasogastric Coca-Cola lavage.

    PubMed

    Ladas, Spiros D; Triantafyllou, Konstantinos; Tzathas, Charalabos; Tassios, Pericles; Rokkas, Theodore; Raptis, Sotirios A

    2002-07-01

    Large gastric phytobezoars may occur in patients with gastric dysmotility disorders. Treatment options include dissolution with enzymes, endoscopic fragmentation with removal or aspiration, and surgery. We report our experience with nasogastric cola lavage therapy. Over an 8-year period, five consecutive patients were referred to our unit for endoscopic treatment of large gastric phytobezoars. They included one patient with lobectomy for lung cancer and four patients with diabetic gastroparesis. An initial attempt of endoscopic fragmentation and removal was unsuccessful. Patients were treated with 3 l of Coca-Cola nasogastric lavage over 12 h. Nasogastric lavage was very well tolerated by the patients. Complete phytobezoar dissolution was achieved in one session in all cases. There were no procedure-related complications. The dissolution of large gastric phytobezoars with cola nasogastric lavage is a safe, rapid and effective method. Patients may be treated in the medical ward, avoiding therapeutic endoscopy or surgery.

  9. Real-time image-guided nasogastric feeding tube placement: A case series using Kangaroo with IRIS Technology in an ICU.

    PubMed

    Mizzi, Anna; Cozzi, Silvano; Beretta, Luigi; Greco, Massimiliano; Braga, Marco

    2017-05-01

    Pulmonary misplacement during the blind insertion of enteral feeding tubes is frequent, particularly in ventilated and neurologically impaired patients. This is probably the first clinical study using the Kangaroo Feeding Tube with IRIS technology (IRIS) which incorporates a camera designed to provide anatomic landmark visualization during insertion. The study aim was to evaluate IRIS performance during bedside gastric placement. This is the first prospective study to collect data on the use of IRIS. Twenty consecutive unconscious patients requiring enteral nutrition were recruited at a single center. IRIS placement was considered complete when a clear image of the gastric mucosa appeared. Correct placement was confirmed using a contrast-enhanced abdominal X-ray. To evaluate the device performance over time, the camera was activated every other day up to 17 d postplacement. In 7 (35%) patients, the trachea was initially visualized, requiring a second placement attempt with the same tube. The IRIS camera allowed recognition of the gastric mucosa in 18 (90%) patients. The esophagogastric junction was identified in one patient, while in a second patient the quality of visualization was poor. Contrast-enhanced X-ray confirmed the gastric placement of IRIS in all patients. IRIS allowed identification of gastric mucosa in 14 (70%) patients 3 d after placement. Performance progressively declined with time (P = 0.006, chi-square for trend). IRIS placement could have spared X-ray confirmation in almost all patients and prevented misplacement into the airway in about one third. Visualization quality needs to be improved, particularly after the first week. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Office-based insertion of pressure equalization tubes: the role of laser-assisted tympanic membrane fenestration.

    PubMed

    Brodsky, L; Brookhauser, P; Chait, D; Reilly, J; Deutsch, E; Cook, S; Waner, M; Shaha, S; Nauenberg, E

    1999-12-01

    To describe the role of the hand-held otoscope combined with a flashscanner CO2 laser, OtoLAM (ESC/Sharplan, Yokneam, Israel), for pressure equalization tube (PET) insertion in an office setting. Prospective, multisite, clinical cohort trial (Institutional Review Board approved; informed consent) in the setting of pediatric otolaryngology outpatient departments at four tertiary care children's hospitals. Selected for the study were 54 patients (96 ears), ages 6 months to 23 years, who met standard indications for PET insertion using cold-knife myringotomy and tube insertion under general anesthesia. PETs were indicated for recurrent otitis media, chronic otitis media with effusion, and eustachian tube dysfunction-all unresponsive to medical therapy. Topical anesthesia was achieved with iontophoresis (n = 1) or topical anesthesia: 8% tetracaine on an Otowick (Xomed Surgical Products, Jacksonville, FL, catalogue No. 400141) against the tympanic membrane for 45 to 180 minutes (n = 53). Laser-assisted tympanic membrane fenestration was performed with the OtoLAM set at single pulse, 2.0- to 2.6-mm spot size, and between 3 and 18 W. Insertion of grommets was accomplished using the otomicroscope and an "alligator" microforceps. Restraints with papoose were used in 79% of children with a mean age of 34.4 months (SD = 60.9 mo). Clinical, parent/patient, and physician satisfaction and comparative cost impact outcomes are described. All ears but three (3%) underwent successful placement of a PET. Pain was described as "absent" in 39%, "present but tolerable" in 30%, and "severe" in 30% of children at the time of procedure; 5 minutes after the procedure pain was described as "absent" in 75%, "present but tolerable" in 22%, and "severe" in 3%. Tube plugging (3 of 74 available ears; 4%) or persistent otorrhea (1 of 74 ears; 1.4%) occurred infrequently at the 1-month follow-up. Before PET insertion, hearing loss was noted in 66% of cases (mild, 38%; moderate, 22%; and severe, 6

  11. Intra-cavitary dosimetry for IMRT head and neck treatment using thermoluminescent dosimeters in a naso-oesophageal tube.

    PubMed

    Gagliardi, F M; Roxby, K J; Engström, P E; Crosbie, J C

    2009-06-21

    Complex intensity-modulated radiation therapy (IMRT) treatment plans require rigorous quality assurance tests. The aim of this study was to independently verify the delivered dose inside the patient in the region of the treatment site. A flexible naso-gastric tube containing thermoluminescent dosimeters (TLDs) was inserted into the oesophagus via the sinus cavity before the patient's first treatment. Lead markers were also inserted into the tube in order that the TLD positions could be accurately determined from the lateral and anterior-posterior electronic portal images taken prior to treatment. The measured dose was corrected for both daily linac output variations and the estimated dose received from the portal images. The predicted dose for each TLD was determined from the treatment planning system and compared to the measured TLD doses. The results comprise 431 TLD measurements on 43 patients. The mean measured-to-predicted dose ratio was 0.988 +/- 0.011 (95% confidence interval) for measured doses above 0.2 Gy. There was a variation in this ratio when the measurements were separated into low dose (0.2-1.0 Gy), medium dose (1.0-1.8 Gy) and high dose (>1.8 Gy) measurements. The TLD-loaded, naso-oesophageal tube for in vivo dose verification is straightforward to implement, and well tolerated by patients. It provides independent reassurance of the delivered dose for head and neck IMRT.

  12. Intra-cavitary dosimetry for IMRT head and neck treatment using thermoluminescent dosimeters in a naso-oesophageal tube

    NASA Astrophysics Data System (ADS)

    Gagliardi, F. M.; Roxby, K. J.; Engström, P. E.; Crosbie, J. C.

    2009-06-01

    Complex intensity-modulated radiation therapy (IMRT) treatment plans require rigorous quality assurance tests. The aim of this study was to independently verify the delivered dose inside the patient in the region of the treatment site. A flexible naso-gastric tube containing thermoluminescent dosimeters (TLDs) was inserted into the oesophagus via the sinus cavity before the patient's first treatment. Lead markers were also inserted into the tube in order that the TLD positions could be accurately determined from the lateral and anterior-posterior electronic portal images taken prior to treatment. The measured dose was corrected for both daily linac output variations and the estimated dose received from the portal images. The predicted dose for each TLD was determined from the treatment planning system and compared to the measured TLD doses. The results comprise 431 TLD measurements on 43 patients. The mean measured-to-predicted dose ratio was 0.988 ± 0.011 (95% confidence interval) for measured doses above 0.2 Gy. There was a variation in this ratio when the measurements were separated into low dose (0.2-1.0 Gy), medium dose (1.0-1.8 Gy) and high dose (>1.8 Gy) measurements. The TLD-loaded, naso-oesophageal tube for in vivo dose verification is straightforward to implement, and well tolerated by patients. It provides independent reassurance of the delivered dose for head and neck IMRT.

  13. Failure of nasogastric omeprazole suspension in pediatric intensive care patients.

    PubMed

    Haizlip, Julie A; Lugo, Ralph A; Cash, Jared J; Vernon, Donald D

    2005-03-01

    To determine the efficacy of nasogastric administration of omeprazole suspension in raising the gastric pH >4 in critically ill pediatric patients and to determine the most appropriate dosing regimen for this indication. Open-label pharmacodynamic study. Twenty-six bed tertiary-care pediatric intensive care unit. Mechanically ventilated children aged 1-18 yrs with an additional risk factor for stress ulcer formation. Continuous gastric pH monitoring was performed during administration and dose titration of omeprazole suspension to achieve the goal of gastric pH >4 for greater than 75% of the dosing interval. Data were collected from 18 patients. Subjects were categorized based on the pharmacologic response to nasogastric administration of 1 mg/kg omeprazole suspension (maximum 20 mg) as rapid (n = 9), late (n = 5), and nonresponders (n = 4). Rapid responders required 0.72 mg/kg per day omeprazole suspension to achieve adequate gastric pH elevation for stress ulcer prophylaxis. Late responders required 1.58 mg/kg per day. Nonresponders did not achieve adequate elevation of gastric pH for stress ulcer prophylaxis. Nasogastric administration of omeprazole suspension has variable efficacy in critically ill pediatric patients. Half of the studied subjects either required significant dose titrations to achieve gastric acid suppression or did not respond to nasogastric administration of omeprazole suspension.

  14. Development of CMTD (Curved Multi-Tubed Device) -system III and its application to the needle-insertion for liver.

    PubMed

    Furusho, Junji; Kobayashi, Hiroshi; Kikuchi, Takehito; Yamamoto, Tatsuro; Tanaka, Hidekazu; Terayama, Motokazu; Monden, Morito

    2008-01-01

    The purpose of this study is to realize the mechanically-controllable needle-insertion system using the CMTD (Curved Multi-Tube Device) which was developed by Furusho Laboratory. A CMTD, was developed for minimally-invasive surgery and needle insertion. And we use ultrasonograph as a sensing device to detect the position of bible duct or tumor and the orientation and position of the needle which is inserted into liver. This system makes safe minimally-invasive surgery possible, because all complex mechanisms are arranged outside of the body.

  15. Spring/dimple instrument tube restraint

    DOEpatents

    DeMario, Edmund E.; Lawson, Charles N.

    1993-01-01

    A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs.

  16. Spring/dimple instrument tube restraint

    DOEpatents

    DeMario, E.E.; Lawson, C.N.

    1993-11-23

    A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs. 7 figures.

  17. Mortality after nasogastric tube feeding initiation in long-term care elderly with oropharyngeal dysphagia--the contribution of refeeding syndrome.

    PubMed

    Lubart, Emilia; Leibovitz, Arthur; Dror, Yosef; Katz, Elena; Segal, Refael

    2009-01-01

    The refeeding syndrome (RS) is an underappreciated but clinically important entity characterized by acute electrolyte abnormalities, mainly hypophosphatemia, fluid retention and dysfunction of various organs and systems, which can result in significant morbidity and occasionally death. To examine the incidence of death cases and death causes following nasogastric tube (NGT) feeding initiation in frail elderly with particular reference to RS. Forty patients with feeding problems for at least 72 h before restarting of alimentation by NGT were included. Excluded were those in any critical clinical situation. Clinical parameters and nutritional assessment were recorded before and after refeeding. Blood samples were taken before, daily for the first 3 days and 1 week after refeeding initiation. During the 1st week of refeeding, 9 patients (22.5%) died and within 1 month 10 more, summing to 47.5%. Most deaths were due to infectious causes [15 out of 19, (79%)]; some were due to no obvious reason [4 out of 19, (21%)]. Significant electrolyte changes were observed in the 2-3 days following refeeding. Significant were the decreases in phosphorus and elevations in potassium and lymphocytes (day 7). We found no correlations between the severity of decreases in levels of phosphorus and mortality. Mortality after NGT feeding initiation was high, mainly due to infectious complications. However, in a considerable number of patients hypophosphatemia was noted, suggesting that RS could be a contributory factor of mortality. Since this is a treatable condition, more attention should be paid to detecting and coping with this problem. Copyright 2009 S. Karger AG, Basel.

  18. Continuous nasogastric tube feeding: monitoring by combined use of refractometry and traditional gastric residual volumes.

    PubMed

    Chang, W-K; McClave, S-A; Chao, Y-C

    2004-02-01

    Traditional use of gastric residual volumes (GRVs) is insensitive and cannot distinguish retained enteral formula from the large volume of endogenous secretions. We designed this prospective study to determine whether refractometry and Brix value (BV) measurements could be used to monitor gastric emptying and tolerance in patients receiving continuous enteral feeding. Thirty-six patients on continuous nasogastric tube feeding were divided into two groups; patients with lower GRVs (<75 ml) in Group 1, patients with higher GRVs (>75 ml) in Group 2. Upon entry, all gastric contents were aspirated, the volume was recorded (Asp GRV), BV measurements were made by refractometry, and then the contents were reinstilled but diluted with 30 ml additional water. Finally, a small amount was reaspirated and repeat BV measurements were made. Three hours later, the entire procedure was repeated a second time. The BV ratio, calculated (Cal) GRV, and volume of formula remaining were calculated by derived equations. Mean BV ratios were significantly higher for those patients in Group 2 compared to those in Group 1. All but one of the 22 patients (95%) in Group 1 had a volume of formula remaining in the stomach estimated on both measurements to be less than the hourly infusion rate (all these patients had BV ratios <70%). In contrast, six of the 14 patients in Group 2 (43%) on both measurements were estimated to have volumes of formula remaining that were greater than the hourly infusion rate (all these patients had BV ratios >70%). Three of the Group 2 patients (21%) whose initial measurement showed evidence for retention of formula, improved on repeat follow-up measurement assuring adequate gastric emptying. The remaining five patients from Group 2 (35%) had a volume of formula remaining that was less than the hourly infusion rate on both measurements. The pattern of Asp GRVs and serial pre- and post-dilution BVs failed to differentiate these patients in Group 2 with potential

  19. Tracheopleuropulmonary injuries following enteral tube insertion.

    PubMed Central

    Odocha, O.; Lowery, R. C.; Mezghebe, H. M.; Siram, S. M.; Warner, O. G.

    1989-01-01

    Eighty-three cases of tracheopleuropulmonary injuries complicating enteral tube feeding are analyzed to identify the patterns of injury, and precipitating factors and ways to avoid them. Six new cases observed by the authors and 77 other cases cited in British literature between 1976 and 1987 are presented. In recent years, reports of this complication have been increasing, apparently in a geometrical progression: 8%, 18%, and 74% were reported between 1976 to 1979, 1980 to 1983, and 1984 to 1987, respectively. Sixty-one percent occurred in patients aged 60 years or older. Most of the patients (84%) were seriously ill, which compounded their complications. Seventy-four percent of all injuries were committed by house staff; the narrow bore tube with guide wire was used in 77% of cases. Less than reliable methods were used to confirm tube position in most instances. The presence of cuffed endotracheal tubes did not offer protection. The patients on mechanical ventilation tended to deteriorate if they developed a pneumothorax once the malpositioned tubes were removed. Of the cases reviewed for this report, 18 deaths occurred; 72% being directly related to the tube injuries. Lack of awareness, inadequate confirmatory methods, and insufficient supervision accounted for most of these preventable complications. Educating house/nursing staff in the use of the new tubes, closer supervision, and the application of equal measures of care and caution as employed in other invasive and potentially dangerous procedures are recommended to avoid disastrous outcome. PMID:2496234

  20. Survival times with and without tube feeding in patients with dementia or psychiatric diseases in Japan.

    PubMed

    Takayama, Keiko; Hirayama, Keisuke; Hirao, Akihiko; Kondo, Keiko; Hayashi, Hideki; Kadota, Koichi; Asaba, Hiroyuki; Ishizu, Hideki; Nakata, Kenji; Kurisu, Kairi; Oshima, Etsuko; Yokota, Osamu; Yamada, Norihito; Terada, Seishi

    2017-11-01

    It is widely supposed that there has been no evidence of increased survival in patients with advanced dementia receiving enteral tube feeding. However, more than a few studies have reported no harmful outcome from tube feeding in dementia patients compared to in patients without dementia. This was a retrospective study. Nine psychiatric hospitals in Okayama Prefecture participated in this survey. All inpatients fulfilling the entry criteria were evaluated. All subjects suffered from difficulty with oral intake. Attending physicians thought that the patients could not live without long-term artificial nutrition. The physicians decided whether to make use of long-term artificial nutrition between January 2012 and December 2014. We evaluated 185 patients. Their mean age was 76.6 ± 11.4 years. Of all subjects, patients with probable Alzheimer's disease (n = 78) formed the biggest group, schizophrenia patients (n = 44) the second, and those with vascular dementia (n = 30) the third. The median survival times were 711 days for patients with tube feeding and 61 days for patients without tube feeding. In a comparison different types of tube feeding, median survival times were 611 days for patients with a nasogastric tube and more than 1000 days for those with a percutaneous endoscopic gastrostomy tube. Patients with tube feeding survived longer than those without tube feeding, even among dementia patients. This study suggests that enteral nutrition for patients with dementia prolongs survival. Additionally, percutaneous endoscopic gastrostomy tube feeding may be safer than nasogastric tube feeding among patients in psychiatric hospitals. © 2017 Japanese Psychogeriatric Society.

  1. Leakproof Swaged Joints in Thin-Wall Tubing

    NASA Technical Reports Server (NTRS)

    Stuckenberg, F. H.; Crockett, L. K.; Snyder, W. E.

    1986-01-01

    Tubular inserts reinforce joints, reducing incidence of leaks. In new swaging technique, tubular inserts placed inside ends of both tubes to be joined. Made from thicker-wall tubing with outside diameter that matches inside diameter of thin tubing swaged, inserts support tube ends at joint. They ensure more uniform contact between swage fitting and tubing. New swaging technique developed for Al/Ti/V-alloy hydraulic supply lines.

  2. Paramedic King Laryngeal Tube airway insertion versus endotracheal intubation in simulated pediatric respiratory arrest.

    PubMed

    Mitchell, Michael S; Lee White, Marjorie; King, William D; Wang, Henry E

    2012-01-01

    Pediatric endotracheal intubation (ETI) is difficult and can have serious adverse events when performed by paramedics in the prehospital setting. Paramedics may use the King Laryngeal Tube airway (KLT) in difficult adult airways, but only limited data describe their application in pediatric patients. To compare paramedic airway insertion speed and complications between KLT and ETI in a simulated model of pediatric respiratory arrest. This prospective, randomized trial included paramedics and senior paramedic students with limited prior KLT experience. We provided brief training on pediatric KLT insertion. Using a random allocation protocol, participants performed both ETI and KLT on a pediatric mannequin (6-month old size) in simulated respiratory arrest. The primary outcomes were 1) elapsed time to successful airway placement (seconds), and 2) proper airway positioning. We compared airway insertion performance between KLT and ETI using the Wilcoxon signed-ranks test. Subjects also indicated their preferred airway device. The 25 subjects included 19 paramedics and 6 senior paramedic students. Two subjects had prior adult KLT experience. Airway insertion time was not statistically different between the KLT (median 27 secs) and ETI (median 31 secs) (p = 0.08). Esophageal intubation occurred in 2 of 25 (8%) ETI. Airway leak occurred in 3 of 25 (12%) KLT, but ventilation remained satisfactory. Eighty-four percent of the subjects preferred the KLT over ETI. Paramedics and paramedic students demonstrated similar airway insertion performance between KLT and ETI in simulated, pediatric respiratory arrest. Most subjects preferred KLT. KLT may provide a viable alternative to ETI in prehospital pediatric airway management.

  3. Forgotten T-tube in the middle ear.

    PubMed

    Shakeel, Muhammad; Trinidade, Aaron; Khan, Imran; Ah-See, Kim Wong

    2012-05-01

    Retention within the middle ear cleft is an unusual complication of T-tube insertion. A 40-year-old woman with Kartagener's Syndrome presented with hearing impairment in the right ear. She was found to have a previously inserted Goode T-tube lying within the middle ear behind an intact drum. She underwent successful removal of the T-tube via a myringotomy, and a new tube was re-inserted. Migration of a T-tube into the middle ear cleft should always be kept in mind in patients who present with otological symptoms and have a history of T-tube insertion, even in the presence of an intact drum.

  4. Experimental Analysis of the Thermo-Hydraulic Performance on a Cylindrical Parabolic Concentrating Solar Water Heater with Twisted Tape Inserts in an Absorber Tube

    NASA Astrophysics Data System (ADS)

    Kumar, Birendra; Nayak, Rajen Kumar; Singh, S. N.

    2018-05-01

    A twisted tape inserted in an absorber tube may be an excellent option to enhance the performance of a cylindrical parabolic concentrating solar collector (CPC). The present work is an experimental study of the flow and heat transfer with and without twisted tape inserts in the absorber tube of a CPC. Results are presented for mass flow rates of water, ṁ=0.0198-0.0525 kg/s, twist ratio, y=5-10 and Reynolds number, Re=2577.46-6785.55. In the present study, we found that the outlet water temperature, collector efficiency and Nusselt number (Nu) are higher in the twisted tapes as compared to those without the twisted tape inserts in the absorber tube of the CPC. For fixed mass flow rate of water ṁ, the To and η increased with the decrease in twist ratio, y, and is higher in lower twist ratio, y=5, of the twisted tapes. The whole experiment was performed at the Indian Institute of Technology (ISM) in Dhanbad, India during the months of March-April 2017. Based on the experimental data, the correlations for the Nu and friction factor were also developed.

  5. Intercostal drainage tube or intracardiac drainage tube?

    PubMed

    Anitha, N; Kamath, S Ganesh; Khymdeit, Edison; Prabhu, Manjunath

    2016-01-01

    Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  6. Gastroenteric tube feeding: Techniques, problems and solutions

    PubMed Central

    Blumenstein, Irina; Shastri, Yogesh M; Stein, Jürgen

    2014-01-01

    Gastroenteric tube feeding plays a major role in the management of patients with poor voluntary intake, chronic neurological or mechanical dysphagia or gut dysfunction, and patients who are critically ill. However, despite the benefits and widespread use of enteral tube feeding, some patients experience complications. This review aims to discuss and compare current knowledge regarding the clinical application of enteral tube feeding, together with associated complications and special aspects. We conducted an extensive literature search on PubMed, Embase and Medline using index terms relating to enteral access, enteral feeding/nutrition, tube feeding, percutaneous endoscopic gastrostomy/jejunostomy, endoscopic nasoenteric tube, nasogastric tube, and refeeding syndrome. The literature showed common routes of enteral access to include nasoenteral tube, gastrostomy and jejunostomy, while complications fall into four major categories: mechanical, e.g., tube blockage or removal; gastrointestinal, e.g., diarrhea; infectious e.g., aspiration pneumonia, tube site infection; and metabolic, e.g., refeeding syndrome, hyperglycemia. Although the type and frequency of complications arising from tube feeding vary considerably according to the chosen access route, gastrointestinal complications are without doubt the most common. Complications associated with enteral tube feeding can be reduced by careful observance of guidelines, including those related to food composition, administration rate, portion size, food temperature and patient supervision. PMID:25024606

  7. App-based serious gaming for training of chest tube insertion: study protocol for a randomized controlled trial.

    PubMed

    Friedrich, Mirco; Bergdolt, Christian; Haubruck, Patrick; Bruckner, Thomas; Kowalewski, Karl-Friedrich; Müller-Stich, Beat Peter; Tanner, Michael C; Nickel, Felix

    2017-02-06

    Chest tube insertion is a standard intervention for management of various injuries of the thorax. Quick and accurate execution facilitates efficient therapy without further complications. Here, we propose a new training concept comprised of e-learning elements as well as continuous rating using an objective structured assessment of technical skills (OSATS) tool. The study protocol is presented for a randomized trial to evaluate e-learning with app-based serious gaming for chest drain insertion. The proposed randomized trial will be carried out at the Department of Orthopedics and Traumatology at Heidelberg University in the context of regular curricular teaching for medical students (n = 90, 3rd to 6th year). The intervention group will use e-learning with the serious gaming app Touch Surgery (TM) for chest drain insertion, whereas the control group uses serious gaming for an unrelated procedure. Primary endpoint is operative performance of chest drain insertion in a porcine cadaveric model according to OSATS. The randomized trial will help determine the value of e-learning with the serious gaming app Touch Surgery (TM) for chest drain insertion by using the OSATS score. The study will improve surgical training for trauma situations. Trial Registration Number, DRKS00009994 . Registered on 27 May 2016.

  8. Insertion of the endotracheal tube, laryngeal mask airway and oesophageal-tracheal Combitube. A 6-month comparative prospective study of acquisition and retention skills by medical students.

    PubMed

    Weksler, N; Tarnopolski, A; Klein, M; Schily, M; Rozentsveig, V; Shapira, A R; Gurman, G M

    2005-05-01

    To assess the ability of medical students to learn and retain skills of airway manipulation for insertion of the endotracheal tube, the laryngeal mask airway (Laryngeal Mask Company, Henley-on-Thames, UK) and the oesophageal-tracheal Combitube (Kendall-Sheridan Catheter Corp., Argyle, NY, USA). A 6-month prospective study was conducted among fifth-year medical students attending a 3-week clerkship in the Division of Anesthesiology and Critical Care Medicine in the Soroka Medical Center. All the students viewed a demonstration of insertion technique for the endotracheal tube, the laryngeal mask airway and the Combitube, followed by formal teaching in a mannikin. At the end of the program, the insertion skills were demonstrated in the mannikin, the success rate on the first attempt was registered and the students were requested to assess (by questionnaire) their ability to execute airway manipulation (phase 1). Six months later, the students were requested to repeat the insertion technique, and a similar re-evaluation applied (phase 2). The success rate, during the first phase, at first attempts was 100% for the laryngeal mask airway and the Combitube, compared to 57.4% for the endotracheal tube (P < 0.02), and 92.6%, 96.2% and 62.9% (P < 0.02) respectively for the second phase of the study. Learning and retention skills of medical students, in a mannikin, are more accentuated with the laryngeal mask airway and the Combitube than seen with an endotracheal tube.

  9. Higher-Quality Weld Joints for Tube Sections

    NASA Technical Reports Server (NTRS)

    Olszewski, John T.

    1987-01-01

    Less material in weld inserts results in better fusion. Redesigned insert for joining tubes by welding improves quality of weld. In new insert, leg of T shorter so it does not protrude into tube cavity.

  10. End Restraints for Impact-Energy-Absorbing Tube Specimens

    NASA Technical Reports Server (NTRS)

    Farley, G. L.; Modlin, J. T.

    1985-01-01

    Inexpensive device developed that eliminates tipping problem without affecting crushing process. Device consists of soft sponge-rubber insert approximately 0.5 inches (1.3 centimeters) thick, cut to same diameter as internal diameter of tube specimen. Metal washer, slightly smaller than internal diameter of tube, placed on top of rubber insert. Screw passed through washer and rubber insert and threaded into base of test machine. As screw tightened against washer, rubber insert compressed and expands radially. Radial expansion applies pressure against internal wall of tube specimen, which provides sufficient support to tube to prevent tipping.

  11. Managing a chest tube and drainage system.

    PubMed

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  12. Efficacy of the laryngeal tube by inexperienced personnel.

    PubMed

    Asai, Takashi; Hidaka, Ikuriho; Kawachi, Shoji

    2002-11-01

    We compared the laryngeal tube and the laryngeal mask in the ease of insertion, ventilation volume and the incidence of gastric insufflation by inexperienced personnel. In a randomized, cross-over design, each of 28 students of a Fire Defense Academy attempted to insert the laryngeal tube and laryngeal mask in turn using an airway management trainer manikin. A self-inflating bag (2000 ml) was attached and ventilation volume was measured. The number of attempts at the insertion and the presence or absence of gastric insufflation were also recorded. After completion of the study, each student was asked whether insertion of one device was easier than the other. All 28 students could insert the laryngeal tube at the first attempt. As for the laryngeal mask, 27 could insert it at the first attempt, whereas the remaining one student could insert it after two attempts. The tidal volume was significantly greater for the laryngeal tube (median 842 ml) than the laryngeal mask (median 716 ml) (95%CI for median difference: 10-116 ml; P < 0.02). The incidence of gastric insufflation was significantly lower for the laryngeal tube (2 times) than for the laryngeal mask (10 times) (P < 0.05). Twenty six of 28 students stated that insertion of the laryngeal tube was easier than insertion of the laryngeal mask, whereas the remaining two stated that there was no difference in the ease of insertion between two devices. Therefore, the laryngeal tube has a potential role in providing a clear airway during cardiopulmonary resuscitation. Copyright 2002 Elsevier Science Ireland Ltd.

  13. Turbine nozzle stage having thermocouple guide tube

    DOEpatents

    Schotsch, Margaret Jones; Kirkpatrick, Francis Lawrence; Lapine, Eric Michael

    2002-01-01

    A guide tube is fixed adjacent opposite ends in outer and inner covers of a nozzle stage segment. The guide tube is serpentine in shape between the outer and inner covers and extends through a nozzle vane. An insert is disposed in the nozzle vane and has apertures to accommodate serpentine portions of the guide tube. Cooling steam is also supplied through chambers of the insert on opposite sides of a central insert chamber containing the guide tube. The opposite ends of the guide tube are fixed to sleeves, in turn fixed to the outer and inner covers.

  14. Nasogastric feeding tube

    MedlinePlus

    ... chap 16. Ziegler TR. Malnutrition, nutritional assessment, and nutritional support in adult hospitalized patients. In: Goldman L, Schafer ... A.M. Editorial team. Related MedlinePlus Health Topics Nutritional Support Browse the Encyclopedia A.D.A.M., Inc. ...

  15. A Proposal for a Study of Bulimia Among Women in the United States Air Force

    DTIC Science & Technology

    1988-12-01

    to be effective (7). Activities on many bases are limitless and frequently include softball, basketball, football, baseball, volleyball, soccer ...34most authorities recognize that the recommended body weight of these tables does not provide an accurate assessment of body fat because of the wide...how many die undiagnosed. Starvation, -uic4 - inadequate potassium intake and stomach perforation from insertion of a nasogastric tube are the more

  16. Outcomes of percutaneous endoscopic gastrostomy tube insertion in respiratory impaired amyotrophic lateral sclerosis patients under noninvasive ventilation.

    PubMed

    Czell, David; Bauer, Matthias; Binek, Janek; Schoch, Otto D; Weber, Markus

    2013-05-01

    Percutaneous endoscopic gastrostomy (PEG) tube placement in amyotrophic lateral sclerosis (ALS) patients with impaired respiratory function is associated with an increased risk of peri-procedural and post-interventional complications. It was the aim of the study to analyze peri- and post-interventional complications and survival after PEG tube placement under noninvasive ventilation (NIV) in ALS patients with various degrees of respiratory impairment. Twenty-six subjects were included in this retrospective case study. Prior to PEG tube placement, training with ventilatory support via an oronasal mask was performed with ALS subjects on the pneumology ward. PEG placement was then performed under continuous NIV. FVC, sniff nasal inspiratory pressure, and demographic data were assessed. Complication rates and 1-month and overall survival rates were analyzed. There were no deaths within 24 hours after PEG placement. One subject died within the first month. The mean survival rate after PEG was 12 ± 10 months (range 0.6-42 months). There was no difference in post-PEG survival between subjects with moderately (> 50%) and severely (< 50%) impaired FVC. In this case series, PEG tube insertion was associated with minimal peri- and post-procedural complications. The low complication rate might be due to the systematic use of procedural NIV in ALS subjects.

  17. Screw-Thread Inserts As Temporary Flow Restrictors

    NASA Technical Reports Server (NTRS)

    Trimarchi, Paul

    1992-01-01

    Coil-spring screw-thread inserts found useful as temporary flow restrictors. Inserts placed in holes through which flow restricted, effectively reducing cross sections available for flow. Friction alone holds inserts against moderate upstream pressures. Use of coil-spring thread inserts as flow restrictors conceived as inexpensive solution to problem of adjusting flow of oxygen through orifices in faceplate into hydrogen/oxygen combustion chamber. Installation and removal of threaded inserts gentle enough not to deform orifice tubes.

  18. Massive hemorrhage after Kasai portoenterostomy in a patient with a congenital extrahepatic portosystemic shunt, malrotation and a double aortic arch: report of a case.

    PubMed

    Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Tanaka, Yujiro; Sato, Kaori; Jimbo, Takahiro; Deie, Kyoichi; Koiwai, Kazuki; Nomura, Koji; Iwanaka, Tadashi

    2014-08-01

    A newborn female was transferred to our hospital presenting with severe respiratory distress. She underwent tracheal intubation and nasogastric tubing. Investigations revealed a congenital extrahepatic portosystemic shunt (CEPS) type 1, biliary atresia, heterotaxia, polysplenia, malrotation and a double aortic arch (DAA). She underwent the Kasai portoenterostomy and the Ladd procedure when she was 29 days old. On postoperative day 20, she developed sudden hematemesis with bright red blood. Endoscopy showed massive bleeding from an esophageal ulcer, and endoscopic therapy was performed successfully. During left thoracotomy, an aortoesophageal fistula (AEF) was detected and repaired by direct suturing. The postoperative course was uneventful. CEPS type 1 is commonly associated with other congenital malformations; however, there have been no previous reports of an association between CEPS and DAA. Nasogastric tube insertion in a patient with DAA can result in catastrophic AEF. The treatment strategy should be carefully considered in patients with CEPS type 1 and multiple congenital fetal anomalies.

  19. Repairing Hard-to-Reach Cracks in Heat-Exchanger Tubes

    NASA Technical Reports Server (NTRS)

    Mills, R. C., Sr.; Duesberg, J.

    1986-01-01

    Inaccessible leaks repaired from accessible side of tube. Fish-Mouth insert placed in cut in leaky heat-exchanger tube. Insert welded or brazed to tube, and remaining open area of cut patched. Method developed for repairing leaks in nozzle coolant tubes of Space Shuttle main engine. Method also used on other types of tubular heat exchangers.

  20. Increased risk of snoring and adenotonsillectomy in children referred for tympanostomy tube insertion.

    PubMed

    Tauman, Riva; Derowe, Ari; Ophir, Orna; Greenfeld, Michal; Sivan, Yakov

    2010-02-01

    Eustachian tube dysfunction and sleep-disordered breathing (SDB) share common pathophysiologic mechanisms. Our objective was to investigate whether children referred for isolated TTI (tympanostomy tube insertion) are at increased risk for snoring and upper airway procedures. Telephone interviews to parents of children who underwent isolated TTI and to age- and gender-matched controls were conducted. Four hundred fifty-seven children were included in the study; 352 had isolated TTI (study group) and 105 children were controls. Twenty-two percent of children in the study group were reported to snore compared with 7.6% in the controls (p=0.001). Eighteen percent of children in the study group were reported to have undergone adenotonsillectomy compared with 4.8% in the controls (p=0.0005). Future SDB, i.e., either snoring or adenotonsillectomy following TTI, was found in 34% of children in the study group compared with 11% in the controls (p=0.0004). Children who underwent isolated TTI were at increased risk for future snoring (OR=3.4, CI: 1.6-7.2) and future adenotonsillectomy (OR=4.4, CI: 1.7-11.2). Children who undergo isolated TTI are at increased risk for snoring and for adenotonsillectomy. We suggest that these children be followed for symptoms of SDB on a scheduled basis to allow for early diagnosis and intervention. 2009 Elsevier B.V. All rights reserved.

  1. Effect of timing and method of enteral tube feeding for dysphagic stroke patients (FOOD): a multicentre randomised controlled trial.

    PubMed

    Dennis, M S; Lewis, S C; Warlow, C

    Undernutrition is common in patients admitted with stroke. We aimed to establish whether the timing and route of enteral tube feeding after stroke affected patients' outcomes at 6 months. The FOOD trials consist of three pragmatic multicentre randomised controlled trials, two of which included dysphagic stroke patients. In one trial, patients enrolled within 7 days of admission were randomly allocated to early enteral tube feeding or no tube feeding for more than 7 days (early versus avoid). In the other, patients were allocated percutaneous endoscopic gastrostomy (PEG) or nasogastric feeding. The primary outcome was death or poor outcome at 6 months. Analysis was by intention to treat. Between Nov 1, 1996, and July 31, 2003, 859 patients were enrolled by 83 hospitals in 15 countries into the early versus avoid trial. Early tube feeding was associated with an absolute reduction in risk of death of 5.8% (95% CI -0.8 to 12.5, p=0.09) and a reduction in death or poor outcome of 1.2% (-4.2 to 6.6, p=0.7). In the PEG versus nasogastric tube trial, 321 patients were enrolled by 47 hospitals in 11 countries. PEG feeding was associated with an absolute increase in risk of death of 1.0% (-10.0 to 11.9, p=0.9) and an increased risk of death or poor outcome of 7.8% (0.0 to 15.5, p=0.05). Early tube feeding might reduce case fatality, but at the expense of increasing the proportion surviving with poor outcome. Our data do not support a policy of early initiation of PEG feeding in dysphagic stroke patients.

  2. Complications of ventilation tube insertion in children with and without cleft palate: a nested case-control comparison.

    PubMed

    Smillie, Ian; Robertson, Sophie; Yule, Anna; Wynne, David M; Russell, Craig J H

    2014-10-01

    Optimizing hearing in patients with cleft lip and/or palate (CLP) by early recognition and management of otitis media with effusion is essential for speech development. Some evidence has suggested higher complication rates from ventilation tube (VT) insertion in patients with CLP and has led to a trend not to treat these patients surgically. However, studies have failed to match comparison groups for age and sex. To compare complication rates from VT insertion in pediatric patients with and without CLP. The study used a nested case-control design to evaluate 60 pediatric patients with CLP who underwent VT insertion at a children's hospital. The control group of age- and sex-matched patients was selected from a database of 2943 VT insertions. All patients were administered general anesthesia and underwent VT insertion by a pediatric otorhinolaryngology (ENT) team. The primary outcomes were numbers of otorrhea complications. Secondarily, rates of attendance at an ENT clinic specifically for complications were evaluated. Finally, numbers of complications other than otorrhea were assessed but not statistically analyzed owing to the varied types and low numbers in each group. The control cohort had 151 documented cases of otorrhea compared with 121 in the CLP group (ratio 1.25:1); the difference between groups was not statistically significant (P = .52). There was no significant difference in mean ENT clinic visits per patient for complications between groups (0.80 in the CLP group, 0.78 for controls) (P = .66). Regarding complications other than otorrhea, the control group reported more than the CLP group (43 vs 25; ratio, 1.7:1). Complication rates of VT placement among patients with CLP were not higher than those among patients without CLP. Therefore, treatment with VT insertion should be administered to patients with CLP under the same guidelines as for those without CLP. Indeed, there could be an argument for a shift in practice toward more aggressive

  3. Percutaneous transesophageal gastro-tubing (PTEG) as an alternative long-term tube feeding procedure when gastrostomy is not feasible

    PubMed Central

    Toh Yoon, Ezekiel Wong; Nishihara, Kazuki

    2017-01-01

    Background: Percutaneous transesophageal gastro-tubing (PTEG) is a minimally invasive technique to access the gut via an esophagostomy. However, this procedure is not well known and the literature available is still fairly limited. This observational study was conducted to evaluate our experience using this method as an alternative long-term tube feeding procedure when gastrostomy is not suitable. Methods: A total of 15 patients (10 males and 5 females) who underwent PTEG at our institution from 2012 to 2016 were observed and analyzed in this study. Results: The average age was 80.1 (71–93) years. Underlying conditions that required PTEG were previous gastric resection in 11 patients, left diaphragm disorder in 2 patients, interposing transverse colon between the abdominal wall and anterior gastric wall in 1 patient, and severe gastrostomy site leakage in 1 patient. Tube placement was successful in all patients by approaching the left side of the neck, using a 15 Fr size tube. The mean postoperative length of stay was 22 (8–48) days. Postoperative adverse events included accidental tube dislodgement in three patients, tracheoesophageal fistula in one patient, inferior thyroid artery injury in one patient and thyroid gland mispuncture in one patient. There was no procedure-related mortality nor mortality at 30 days. Eight patients were discharged with some oral intake. Conclusions: PTEG is feasible in patients requiring long-term tube feeding for whom gastrostomy is unsuitable. It is an effective long-term tube feeding procedure and should be offered as a more comfortable alternative to nasogastric tubing. PMID:29204186

  4. Percutaneous transesophageal gastro-tubing (PTEG) as an alternative long-term tube feeding procedure when gastrostomy is not feasible.

    PubMed

    Toh Yoon, Ezekiel Wong; Nishihara, Kazuki

    2017-12-01

    Percutaneous transesophageal gastro-tubing (PTEG) is a minimally invasive technique to access the gut via an esophagostomy. However, this procedure is not well known and the literature available is still fairly limited. This observational study was conducted to evaluate our experience using this method as an alternative long-term tube feeding procedure when gastrostomy is not suitable. A total of 15 patients (10 males and 5 females) who underwent PTEG at our institution from 2012 to 2016 were observed and analyzed in this study. The average age was 80.1 (71-93) years. Underlying conditions that required PTEG were previous gastric resection in 11 patients, left diaphragm disorder in 2 patients, interposing transverse colon between the abdominal wall and anterior gastric wall in 1 patient, and severe gastrostomy site leakage in 1 patient. Tube placement was successful in all patients by approaching the left side of the neck, using a 15 Fr size tube. The mean postoperative length of stay was 22 (8-48) days. Postoperative adverse events included accidental tube dislodgement in three patients, tracheoesophageal fistula in one patient, inferior thyroid artery injury in one patient and thyroid gland mispuncture in one patient. There was no procedure-related mortality nor mortality at 30 days. Eight patients were discharged with some oral intake. PTEG is feasible in patients requiring long-term tube feeding for whom gastrostomy is unsuitable. It is an effective long-term tube feeding procedure and should be offered as a more comfortable alternative to nasogastric tubing.

  5. Relative Bioavailability of Apixaban Solution or Crushed Tablet Formulations Administered by Mouth or Nasogastric Tube in Healthy Subjects.

    PubMed

    Song, Yan; Wang, Xiaoli; Perlstein, Itay; Wang, Jessie; Badawy, Sherif; Frost, Charles; LaCreta, Frank

    2015-08-01

    Crushed tablet and solution formulations of apixaban administered orally or via a nasogastric tube (NGT) may be useful in patients unable to swallow solid dose formulations. It is important to understand whether new formulations and/or methods of administration impact apixaban bioavailability and pharmacokinetic properties. These studies evaluated the relative bioavailability (Frel) of apixaban solution administered orally; oral solution administered via NGT flushed with either 5% dextrose in water (D5W) or with infant formula; oral solution via NGT with a nutritional supplement; and crushed tablet suspended in D5W and administered via NGT. Three open-label, randomized, crossover studies were conducted in healthy adults (study 1: apixaban 10-mg tablet [reference] versus oral solution, both administered PO; study 2: apixaban 5-mg oral solution PO [reference] versus oral solution via NGT flushed with either D5W or infant formula; study 3: apixaban 5-mg oral solution PO [reference] versus apixaban 5-mg oral solution via NGT with a nutritional supplement and versus crushed tablet suspended in D5W and administered via NGT). Point estimates and 90% CIs of the geometric mean ratios (GMRs; test/reference) were generated for Cmax and AUC. Adverse events were recorded throughout each study. Frel of the oral solution was 105% versus tablet, and Frel for oral solution via NGT with D5W flush, infant formula flush, nutritional supplement, and crushed tablet via NGT versus oral solution administration were 96.7%, 92.2%, 81.3%, and 95.1%, respectively. The 90% CIs of the GMRs of all AUCs met the bioequivalence criterion except that of the nutritional supplement (0.766-0.863). The corresponding GMRs for Cmax were 0.977, 0.953, 0.805, 0.682, and 0.884. For the solution via NGT flushed with D5W and for the crushed tablet, the 90% CIs of the Cmax GMRs met the bioequivalence criterion. Apixaban was well tolerated in all 3 studies; most adverse events were mild. Comparable Frel was

  6. Assessment of routine elimination of postoperative nasogastric decompression after Roux-en-Y gastric bypass.

    PubMed

    Huerta, Sergio; Arteaga, James R; Sawicki, Mark P; Liu, Carson D; Livingston, Edward H

    2002-11-01

    Anastomotic disruption after surgical intervention is an infrequent complication, but may lead to severe morbidity and mortality when it occurs. Of the various gastric procedures, the Roux-en-Y gastric bypass (RYGB) has one of the highest risks for anastomotic leakage. Consequently, a nasogastric tube (NGT) is frequently placed when these operations are performed. Most studies examining the outcomes for patients without postoperative NGTs have been relatively small with groups of patients undergoing a variety of operations. Assessing the incidence of anastomotic leaks by routine elimination of postoperative NGTs requires a large number of patients. In this study, we assessed the safety and efficacy of routine elimination of NGTs in a large cohort of patients undergoing a single operation. We reviewed our experience with 1067 patients who underwent RYGB at the UCLA medical center. Fifty-six patients had NGTs routinely placed before the implementation of a standard protocol, which eliminated postoperative NGT decompression. The complication rate for the RYGB patient cohort with and without postoperative NGT was compared. We found no difference in the complication rates between the 2 groups (Fisher exact test; P =.21). Our findings suggest that routine placement of an NGT after RYGB is unnecessary.

  7. Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures.

    PubMed

    Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul

    2016-05-01

    A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.

  8. Incidence of hypochloremic metabolic alkalosis in dogs and cats with and without nasogastric tubes over a period of up to 36 hours in the intensive care unit.

    PubMed

    Chih, Annie; Rudloff, Elke; Waldner, Cheryl; Linklater, Andrew K J

    2018-05-01

    To evaluate the incidence of hypochloremic metabolic alkalosis (HCMA) in dogs and cats in the ICU that had intermittent nasogastric tube (NGT) aspiration for up to 36 hours. Prospective cohort study (December 2013 to October 2014). Privately owned emergency and referral teaching hospital. Forty-nine client-owned dogs and 16 client-owned cats. Patients wherein NGT placement was recommended and client consent was obtained were included in the interventional group. Those with an NGT placed (NGT group) had the NGT aspirated every 4 hours. Patients for whom placement of a NGT was declined by the owner served as a reference group (NoNGT). Venous blood gas and electrolyte values were obtained every 12 hours. Thirty-five dogs and cats had an NGT placed. Thirty dogs and cats did not have an NGT placed. The serum venous blood gas and electrolyte changes were compared over time within the NGT group and between the NGT and NoNGT groups. No cases developed HCMA. In the NGT group, blood pH increased over time. There was no significant difference between the NGT and the NoNGT group in the average value of pH, HCO 3 - , base excess, chloride, or corrected chloride. Serum venous blood gas, chloride, and corrected chloride changes were not associated with the volumes of gastric fluid aspirated over time. In this small population of dogs and cats, intermittent NGT aspiration was not associated with the development of HCMA over a period of up to 36 hours after NGT placement. © Veterinary Emergency and Critical Care Society 2018.

  9. AMEDD Clinical Psychology Short Course Held at Brooke Army Medical Center, San Antonio, Texas, 5-9 June 1991

    DTIC Science & Technology

    1991-06-01

    off after a while, as the triage and surgical teams can only pretend to start the IV’s and insert the nasogastric and chest tubes , and only get to...clinical psychology; -- To examine AMEDD clinical psychology’s support of the Gulf War; and -- To provide a forum for continuing education , exchange of...also provide actual preventive consultation, education and case evaluations to the medical company and all other nearby units. In some FTXs, when

  10. Technique for joining metal tubing

    NASA Technical Reports Server (NTRS)

    Wright, H. W.

    1976-01-01

    Uniform wall thickness and uninterrupted heat transfer is achieved by using shaped metal insert as wall material for joint. Insert acts as support during brazing, after which excess material is ground away to bring joint to original tubing size.

  11. Cuff inflation-supplemented laryngoscope-guided nasal intubation: a comparison of three endotracheal tubes.

    PubMed

    Kumar, Rakesh; Gupta, Ekta; Kumar, Sunil; Rani Sharma, Kavita; Rani Gupta, Neera

    2013-03-01

    Softer endotracheal (ET) tubes are more difficult to navigate in the oropharynx than the stiffer polyvinyl chloride (PVC) tubes during nasotracheal intubation (NTI). Cuff inflation has been used to guide PVC tubes into the laryngeal inlet during blind NTI, but it has not been tested when performing NTI under direct laryngoscopic guidance. We assessed the role of cuff inflation in improving oropharyngeal navigation of 3 ET tubes of varying stiffness during direct laryngoscope-guided NTI. Simultaneously, we also assessed and compared the nasotracheal navigability and incidence of nasal injury with these ET tubes during cuff inflation-supplemented, laryngoscope-guided NTI. One hundred sixty-two adults were randomized to undergo NTI with either a conventional PVC (n = 54), wire reinforced (WR; n = 54) or a silicone-tipped WR (SWR; n = 54) ET tube. Ease of insertion of these tubes was assessed during passage from nose into oropharynx, from oropharynx into laryngeal inlet aided by cuff inflation if needed, and from laryngeal inlet into trachea. Nasal morbidity was assessed by a blinded observer. All ET tubes could be inserted into the trachea. Seventy-one of 162 ET tubes could be inserted from the oropharynx into the laryngeal inlet without cuff inflation. Eighty-six of the remaining 91 tubes that did not enter the laryngeal inlet without cuff inflation could be inserted when using the cuff inflation technique. Thus, a total of 157 ET tubes could be inserted into the laryngeal inlet with cuff inflation (95% confidence interval of difference of proportions between total number of tubes passed [157] and those without cuff inflation [71]: 53% [45%-61%]). The remaining 5 tubes had to be inserted with the help of Magill forceps. The incidence of epistaxis was lowest with the SWR tube (difference of proportions [95% confidence interval] SWR versus PVC 27% [8%-45%]; SWR versus WR 20% [1%-38%]; WR versus PVC 7% [-12% to 26%]). The cuff inflation technique consistently improved

  12. Enteral Tube Feeding and Pneumonia

    ERIC Educational Resources Information Center

    Gray, David Sheridan; Kimmel, David

    2006-01-01

    To determine the effects of enteral tube feeding on the incidence of pneumonia, we performed a retrospective review of all clients at our institution who had gastrostomy or jejunostomy tubes placed over a 10-year period. Ninety-three subjects had a history of pneumonia before feeding tube insertion. Eighty had gastrostomy and 13, jejunostomy…

  13. [A project to reduce the incidence of intubation care errors among foreign health aides].

    PubMed

    Chen, Mei-Ju; Lu, Yu-Hua; Chen, Chiu-Chun; Li, Ai-Cheng

    2014-08-01

    Foreign health aides are the main providers of care for the elderly and the physically disabled in Taiwan. Correct care skills improve patient safety. In 2010, the incidence of mistakes among foreign health aides in our hospital unit was 58% for nasogastric tube care and 57% for tracheostomy tube care. A survey of foreign health aides and nurses in the unit identified the main causes of these mistakes as: communication difficulties, inaccurate instructions given to patients, and a lack of standard operating procedures given to the foreign health aides. This project was designed to reduce the rates of improper nasogastric tube care and improper tracheostomy tube care to 20%, respectively. This project implemented several appropriate measures. We produced patient instruction hand-outs in Bahasa Indonesia, established a dedicated file holder for Bahasa Indonesian tube care reference information, produced Bahasa Indonesian tube-care-related posters, produced a short film about tube care in Bahasa Indonesian, and established a standardized operating procedure for tube care in our unit. Between December 15th and 31st, 2011, we audited the performance of a total of 32 foreign health aides for proper execution of nasogastric tube care (21 aides) and of proper execution of tracheostomy tube care (11 aides). Patients with concurrent nasogastric and tracheostomy tubes were inspected separately for each care group. The incidence of improper care decreased from 58% to 18% nasogastric intubation and 57% to 18% for tracheostomy intubation. This project decreased significantly the incidence of improper tube care by the foreign health aides in our unit. Furthermore, the foreign health aides improved their tube nursing care skills. Therefore, this project improved the quality of patient care.

  14. [Head and neck cancer patients included at home enteral nutrition by tube].

    PubMed

    Cots Seignot, I; Cárdenas Lagranja, G; Puiggròs Llop, C; Chicharro Serrano, L; Pérez-Portabella Maristany, C; Planas Vilà, M

    2009-01-01

    To know characteristics and the patients' evolution with head and neck cancer who received radiotherapy treatment and they were included at a home enteral nutrition (HEN) by feeding tube programme. To analyse the weight evolution according to the start of HEN before or after radiotherapy. Observational study of tube feeding patients with head and neck cancer who were included in HEN programme in our hospital for two years. Variables analysed: gender, age, Body Mass Index (BMI), Karnofsky Index (KI), reason for nutritional support, type of feeding tube, formula used and prescribed caloric contribution, necessity to change access device and HEN days. 62 patients were studied (77.4% men; 22.6% women). Age 64 +/- 10.1 years (rang: 39-90). The dysphagia was the main cause to begin enteral nutrition by feeding tube in these patients. Naso-gastric tube was prevalence (67.7%). The most used formula was polymeric hypercaloric diet with a mean of caloric contribution of 1,629 +/- 267.09 kcal/day. Overall, there was a weight loss in all patients during the study period time. However, patients who began the HEN by feeding tube before the radiotherapy treatment, the BMI did not decrease. All patients who began feeding tube before oncological treatment didn't lose weight for the period of study.

  15. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  16. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  17. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  18. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  19. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  20. 21 CFR 868.5730 - Tracheal tube.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5730 Tracheal tube. (a) Identification. A tracheal tube is a device inserted into a patient's trachea via the nose or mouth and used to maintain an open airway. (b...

  1. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    PubMed Central

    2010-01-01

    Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Conclusions Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery. PMID:20492665

  2. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report.

    PubMed

    Lai, Peng-Sheng; Lo, Chiao; Lin, Long-Wei; Lee, Po-Chu

    2010-05-21

    Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  3. Feeding tube replacement: not always that simple!

    PubMed Central

    Lederman, Alex; Coelho da Rocha, Ricardo Frank; Lourenção, Rodrigo Montenegro

    2015-01-01

    Although surgical gastrostomy is not a technically troublesome surgery, the procedure may be accompanied by unfavorable outcomes. Most complications occur early in the post-operative period and include feeding tube dislodgment, stomal infection, peritonitis, and pneumonia. The authors report the case of an 83-year-old man who underwent a surgical gastrostomy because of a swallowing disorder after an ischemic stroke. Nine months after the procedure, the feeding tube dislodged and a new tube was inserted with a certain delay and with some difficulty, causing a false path and consequently an intrabdominal abscess after diet infusion. The outcome was fatal. The authors call attention for meticulous care with the insertion of feeding tubes and advise the performance of imaging control to assure its precise positioning. PMID:26484325

  4. Tube feeding and quality of life in children with severe neurological impairment.

    PubMed

    Mahant, S; Friedman, J N; Connolly, B; Goia, C; Macarthur, C

    2009-09-01

    To assess the quality of life (QOL) of neurologically impaired children before and after gastrostomy (G) and gastrojejunostomy (GJ) tube insertion. This was a prospective longitudinal study of children with severe neurological impairment who underwent G or GJ tube insertion. At baseline, and at 6 and 12 months after tube insertion, parents rated (1) global QOL and health-related quality of life (HRQOL) using 10 cm visual analogue scales, with 10 representing maximal QOL and (2) HR-QOL using a questionnaire-based measure. Fifty patients, 45 and five of whom underwent G and GJ tube insertion, respectively, were enrolled with a median age of 591 days. Forty-two had a static neurological disorder, and eight had a progressive neurological disorder. The mean weight for age z score increased significantly over time: -2.8 at baseline and -1.8 at 12 months. The mean QOL and HR-QOL scores at baseline were 5.5 and 5.6 out of 10, respectively. There was no significant change in these scores at 6 and 12 months post-tube insertion. Children with a progressive versus a static neurological disorder had a significantly lower QOL over time. Ease of medication administration as well as feeding showed a significant improvement in scores from baseline to 12 months. Parents felt that the G and GJ tube had a positive impact on their child's health at 6 months (86%) and 12 months (84%). QOL as rated by parents did not increase following insertion of a G or GJ tube in neurologically impaired children. However, parents felt that the tube had a positive impact on their child's health, particularly with regards to feeding and administration of medications.

  5. Complications of tube thoracostomy in trauma

    PubMed Central

    Bailey, R

    2000-01-01

    Objective—To assess the complication rate of tube thoracostomy in trauma. To consider whether this rate is high enough to support a selective reduction in the indications for tube thoracostomy in trauma. Methods—A retrospective case series of all trauma patients who underwent tube thoracostomy during a 12 month period at a large UK teaching hospital with an accident and emergency (A&E) department seeing in excess of 125 000 new patients/year. These patients were identified using the hospital audit department computerised retrieval system supplemented by a hand search of both the data collected for the Major Trauma Outcome Study and the A&E admission unit log book. The notes were assessed with regard to the incidence of complications, which were divided into insertional, infective, and positional. Results—Fifty seven chest drains were placed in 47 patients over the 12 month period. Seven patients who died within 48 hours of drain insertion were excluded. The commonest indications for tube thoracostomy were pneumothorax (54%) and haemothorax (20%); 90% of tubes were placed as a result of blunt trauma. The overall complication rate of the procedure was 30%. There were no insertional complications and only one (2%) major complication, which was empyema thoracis. Conclusion—This study reveals no persuasive evidence to support a selective reduction in the indications for tube thoracostomy in trauma. A larger study to confirm or refute these findings must be performed before any change in established safe practice. PMID:10718232

  6. Fluoroscopically guided nose tube drainage of mediastinal abscesses in post-operative gastro-oesophageal anastomotic leakage.

    PubMed

    Xu, Q Y; Yin, G W; Chen, S X; Jiang, F; Bai, X J; Wu, J D

    2012-11-01

    The aim of this study was to retrospectively evaluate the technical success rates and clinical effectiveness of fluoroscopically guided nose tube drainage of mediastinal abscesses and a nasojejunum feeding tube in post-operative gastro-oesophageal anastomotic leakage (GEAL). From January 2006 to June 2011, 18 cases of post-operative GEAL with mediastinal abscesses after oesophagectomy with intrathoracic oesophagogastric anastomotic procedures for oesophageal and cardiac carcinoma were treated by insertion of a nose drainage tube and nasojejunum feeding tube under fluoroscopic guidance. We evaluated the feasibility of two-tube insertion to facilitate leakage site closure and complete resolution of the abscess, and the patients' nutritional benefit was also evaluated by checking the serum albumin level between pre- and post-enteral feeding via the feeding tube. The two tubes were placed successfully under fluoroscopic guidance in 18 patients (100%). The procedure time for two-tube insertion ranged from 20 to 40 min (mean 30 min). 17 patients (94%) achieved leakage site closure after two-tube insertion and had a good tolerance of two tubes in the nasal cavity. The serum albumin level was significant, increased from pre-enteral feeding (2.49 ± 0.42 g dl(-1)) to the post-enteral feeding (3.58 ± 0.47 g dl(-1)) via the feeding tube (p<0.001). The duration of follow-up ranged from 1 to 49 months (mean 19 months). The insertion of nose tube drainage and a nasojejunum feeding tube under fluoroscopic guidance is safe, and it provides effective relief from mediastinal abscesses in GEAL after oesophagectomy. Moreover, our findings indicate that two-tube insertion may be used as a selective procedure to treat mediastinal abscesses in post-operative GEAL. Advances in knowledge Directive drainage of mediastinal abscesses in post-operative GEAL may be an effective treatment.

  7. Experimental investigation of heat transfer and fluid flow behaviour in multiple square perforated twisted tape with square wing inserts heat exchanger tube

    NASA Astrophysics Data System (ADS)

    Suri, Amar Raj Singh; Kumar, Anil; Maithani, Rajesh

    2018-06-01

    The present work deals with experimental investigation of heat transfer and fluid flow characteristics of multiple square perforated twisted tape with wing inserts in a heat exchanger tube. The range of selected geometrical parameters are, perforation width ratio (a/WT) of 0.083-0.333, twist ratio (TL/WT) of 2.0-3.5, wing depth ratio (Wd/WT) of 0.042-0.167 and number of twisted tapes (TP) of 4. The Reynolds number (Ren) selected for experimentation ranges from 5000 to 27,000. The maximum heat transfer and friction factor enhancement was found to be 6.96 and 8.34 times that of plane tube, respectively. The maximum heat transfer enhancement is observed at a a/WT of 0.250, TL/WT of 2.5, and Wd/WT of 0.167.

  8. Experimental investigation of heat transfer and fluid flow behaviour in multiple square perforated twisted tape with square wing inserts heat exchanger tube

    NASA Astrophysics Data System (ADS)

    Suri, Amar Raj Singh; Kumar, Anil; Maithani, Rajesh

    2018-01-01

    The present work deals with experimental investigation of heat transfer and fluid flow characteristics of multiple square perforated twisted tape with wing inserts in a heat exchanger tube. The range of selected geometrical parameters are, perforation width ratio (a/WT) of 0.083-0.333, twist ratio (TL/WT) of 2.0-3.5, wing depth ratio (Wd/WT) of 0.042-0.167 and number of twisted tapes (TP) of 4. The Reynolds number (Ren) selected for experimentation ranges from 5000 to 27,000. The maximum heat transfer and friction factor enhancement was found to be 6.96 and 8.34 times that of plane tube, respectively. The maximum heat transfer enhancement is observed at a a/WT of 0.250, TL/WT of 2.5, and Wd/WT of 0.167.

  9. Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.

    PubMed

    Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M

    2017-04-01

    Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. [INFLUENCE OF THE NUTRITIONAL COMPOSITION OF DIFFERENT FIBER-ENRICHED ENTERAL NUTRITION FORMULAS ON THE ADMINISTRATION TIME BY GRAVITY AND THE RISK OF TUBE FEEDING OBSTRUCTION].

    PubMed

    Bonada Sanjaume, Anna; Gils Contreras, Anna; Salas-Salvadó, Jordi

    2015-08-01

    the administration of enteral nutrition by gravity is a very useful method in clinical practice; nevertheless, it may not be very precise. Indeed, this method presents some important limitations, such as the difficulty in establishing a precise dripping rate and the possibility for the dripping rate decrease depending on the formula. assess the administration time and the risk of clogging of 5 fiber-enriched enteral nutrition formulas with different protein concentrations and caloric density, all administered by gravity through nasogastric (NG) tubes of different sizes. Assess the influence of the composition on the dripping rate, by gravity, of the tested formulas. 5 fiber-enriched EN formulas were compared by using nasogastric tubes of the calibers 8, 10 and 12 Fr. The fluidity of these gravity-administered NE formulas was estimated by timing the complete passage of each formula at full speed, thus allowing one to calculate the mean time of free fall (MTFF) and to register any possible obstruction. Subsequently, an in vitro simulation of a 1 500 ml administration was performed for each formula at a particular speed, so that the administration time was 5 hours. Slowing flow and stagnated flow were detected as indicators of the risk of obstruction. the two products that especially differed in MTFF were the ones with the highest energy concentration. The passage time in free fall of these two products through the 8 Fr tube exceeded four hours. For the rest of the products and NG tubes used, this time was less than 2 hours and 5 minutes. No slowing flow or tube obstruction was detected in free fall and at maximum speed. When the dripping was adjusted to be administered in 5 hours, three of the studied products (those with the least caloric concentration and viscosity) showed slowing flow and, in some cases, the dripping stopped completely. The most important factor associated to the MTFF was the lipid content, followed by viscosity, energy and protein content. The

  11. Chest tube drainage of pleural effusions--an audit of current practice and complications at Hutt Hospital.

    PubMed

    Epstein, Erica; Jayathissa, Sisira; Dee, Stephen

    2012-05-11

    The aims of the study were to review small-bore chest tube insertion practices for drainage of pleural fluid at Hutt Valley District Health Board (HVDHB), to assess complications, and compare the findings with international data. Retrospective analysis of clinical records was completed on all chest tube insertions for drainage of pleural fluid at HVDHB from December 2008 to November 2009. Descriptive statistics were used to present demographics and tube-associated complications. Comparison was made to available similar international data. Small-bore tubes comprised 59/65 (91%) chest tube insertions and 23/25 (92%) complications. Available comparative data was limited. Ultrasound was used in 36% of insertions. Nearly half of chest drains placed for empyema required subsequent cardiothoracic surgical intervention. Chest drain complication rates at HVDHB were comparable to those seen internationally. Referral rates to cardiothoracic surgery for empyema were within described ranges. The importance of procedural training for junior medical staff, optimising safety of drain insertions with ultrasound guidance, and clear clinical governance for chest tube insertions are important in minimising harm from this procedure. Specialist societies need to take a leadership in providing guidance on chest drain insertions to secondary and tertiary hospitals in Australia and New Zealand.

  12. Composite Pulse Tube

    NASA Technical Reports Server (NTRS)

    Martin, Jerry L.; Cloyd, Jason H.

    2007-01-01

    thermal conductivity in the cryogenic temperature range and would typically be made of pure copper to satisfy this requirement. The metallic part is bonded to the nonmetallic part with epoxy. Copper screens are inserted in the metallic part to form the cold-end heat exchanger, then the assembled pulse tube is inserted in the cold tip.

  13. Crimp sealing of tubes flush with or below a fixed surface

    DOEpatents

    Fischer, Jon E.; Walmsley, Don; Wapman, P. Derek

    1996-01-01

    An apparatus for crimp sealing and severing tubes flush or below a fixed surface. Tube crimping below a fixed surface requires an asymmetric die and anvil configuration. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. This asymmetric die and anvil is used when a ductile metal tube and valve assembly are attached to a pressure vessel which has a fixed surface around the base of the tube at the pressure vessel. A flat anvil is placed against the tube. Die guides are placed against the tube on a side opposite the anvil. A pinch-off die is inserted into the die guides against the tube. Adequate clearance for inserting the die and anvil around the tube is needed below the fixed surface. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes.

  14. The upper pouch in oesophageal atresia shows proportional growth during late fetal life.

    PubMed

    Tröbs, R B; Nissen, M; Wald, J

    2018-05-12

    Oesophageal atresia with trachea-oesophageal fistula is a rare foregut malformation that requires surgery soon after birth. Prenatal ultrasound diagnosis is based on the presence of polyhydramnios, a small or non-visible fetal stomach and the blind ending oesophagus, called the upper pouch (1). Neonates present with salivation, coughing, choking and attacks of cyanosis. A diagnosis of oesophageal atresia is confirmed by inserting a nasogastric tube and a thoraco-abdominal X-ray. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Small bore ceramic laser tube inspection light table

    DOEpatents

    Updike, Earl O.

    1990-01-01

    Apparatus for inspecting small bore ceramic laser tubes, which includes a support base with one or more support rollers. A fluorescent light tube is inserted within the laser tube and the laser tube is supported by the support rollers so that a gap is maintained between the laser tube and the fluorescent tube to enable rotation of the laser tube. In operation, the ceramic tube is illuminated from the inside by the fluorescent tube to facilitate visual inspection. Centering the tube around the axial light of the fluorescent tube provides information about straightness and wall thickness of the laser tube itself.

  16. A Peer-Reviewed Instructional Video is as Effective as a Standard Recorded Didactic Lecture in Medical Trainees Performing Chest Tube Insertion: A Randomized Control Trial.

    PubMed

    Saun, Tomas J; Odorizzi, Scott; Yeung, Celine; Johnson, Marjorie; Bandiera, Glen; Dev, Shelly P

    Online medical education resources are becoming an increasingly used modality and many studies have demonstrated their efficacy in procedural instruction. This study sought to determine whether a standardized online procedural video is as effective as a standard recorded didactic teaching session for chest tube insertion. A randomized control trial was conducted. Participants were taught how to insert a chest tube with either a recorded didactic teaching session, or a New England Journal of Medicine (NEJM) video. Participants filled out a questionnaire before and after performing the procedure on a cadaver, which was filmed and assessed by 2 blinded evaluators using a standardized tool. Western University, London, Ontario. Level of clinical care: institutional. A total of 30 fourth-year medical students from 2 graduating classes at the Schulich School of Medicine & Dentistry were screened for eligibility. Two students did not complete the study and were excluded. There were 13 students in the NEJM group, and 15 students in the didactic group. The NEJM group׳s average score was 45.2% (±9.56) on the prequestionnaire, 67.7% (±12.9) for the procedure, and 60.1% (±7.65) on the postquestionnaire. The didactic group׳s average score was 42.8% (±10.9) on the prequestionnaire, 73.7% (±9.90) for the procedure, and 46.5% (±7.46) on the postquestionnaire. There was no difference between the groups on the prequestionnaire (Δ + 2.4%; 95% CI: -5.16 to 9.99), or the procedure (Δ -6.0%; 95% CI: -14.6 to 2.65). The NEJM group had better scores on the postquestionnaire (Δ + 11.15%; 95% CI: 3.74-18.6). The NEJM video was as effective as video-recorded didactic training for teaching the knowledge and technical skills essential for chest tube insertion. Participants expressed high satisfaction with this modality. It may prove to be a helpful adjunct to standard instruction on the topic. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc

  17. An in vitro comparison of tracheostomy tube cuffs

    PubMed Central

    Maguire, Seamus; Haury, Frances; Jew, Korinne

    2015-01-01

    Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the

  18. Numerical investigation of heat transfer and friction factor characteristics in a circular tube fitted with V-cut twisted tape inserts.

    PubMed

    Salman, Sami D; Kadhum, Abdul Amir H; Takriff, Mohd S; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration.

  19. Numerical Investigation of Heat Transfer and Friction Factor Characteristics in a Circular Tube Fitted with V-Cut Twisted Tape Inserts

    PubMed Central

    Salman, Sami D.; Kadhum, Abdul Amir H.; Takriff, Mohd S.; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration. PMID:24078795

  20. Ready or not, here they come: acting interns' experience and perceived competency performing basic medical procedures.

    PubMed

    Coberly, LeAnn; Goldenhar, Linda M

    2007-04-01

    To assess acting interns' (AI's) experience with and perceived level of competency performing 6 basic medical procedures. Fourth-year medical students at the University of Cincinnati (UCCOM) are required to complete 2 AI rotations in Internal Medicine. All AIs in 2003-2004 (n = 150) and 2004-2005 (n = 151) were asked to complete a survey about whether during each of their rotations they had performed and felt competent performing the following procedures: phlebotomy, intravenous (IV) catheter insertion, arterial blood gas (ABG), nasogastric (NG) tube insertion, lumbar puncture (LP), and Foley catheter insertion. Four hundred sixty-seven of 601 possible surveys (across both years and both rotations) were completed (78% response rate). During both rotations, relatively few students performed the procedures, ranging from 9% for Foley catheter insertion (24/208) to 50% for both ABG and NG tube insertion (130/259). The two procedures most often performed were ABG (range 46-50%) and NG tube insertion (range 42-50%). Feelings of competency varied from 12% (LP) to 82% (Foley catheter). Except for LP, if students performed a procedure at least once, they reported feeling more competent (range 85% for ABG to 96% for Foley catheter insertion). Among the students who performed LP during a rotation, many still did not feel competent performing LPs: 23 (74%) in rotation 1 and 20 (40%) in rotation 2. Many fourth-year students at UCCOM do not perform basic procedures during their acting internship rotations. Procedural performance correlates with feelings of competency. Lumbar puncture competency may be too ambitious a goal for medical students.

  1. Improved drainage with active chest tube clearance.

    PubMed

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Crimp sealing of tubes flush with or below a fixed surface

    DOEpatents

    Fischer, J.E.; Walmsley, D.; Wapman, P.D.

    1996-08-20

    An apparatus for crimp sealing and severing tubes flush or below a fixed surface. Tube crimping below a fixed surface requires an asymmetric die and anvil configuration. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. This asymmetric die and anvil is used when a ductile metal tube and valve assembly are attached to a pressure vessel which has a fixed surface around the base of the tube at the pressure vessel. A flat anvil is placed against the tube. Die guides are placed against the tube on a side opposite the anvil. A pinch-off die is inserted into the die guides against the tube. Adequate clearance for inserting the die and anvil around the tube is needed below the fixed surface. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. 8 figs.

  3. Enteral tube feeding for cystic fibrosis.

    PubMed

    Conway, S P; Morton, A; Wolfe, S

    2008-04-16

    Enteral tube feeding is routinely used in many cystic fibrosis centres when weight for height percentage is less than 85%, when there has been weight loss for longer than a two-month period or when there has been no weight gain for two to three months (under five years old) or for six months (over five years old). To examine the evidence that in people with cystic fibrosis supplemental enteral tube feeding improves nutritional status, respiratory function, and quality of life without significant adverse effects. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register which comprises references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings. We also contacted the companies that market enteral feeds and reviewed their databases. Date of the most recent search of the Group's Cystic Fibrosis Trials Register: November 2007. All randomised controlled trials comparing supplemental enteral tube feeding for one month or longer with no specific intervention in people with cystic fibrosis. Thirteen trials were identified by the search; however, none were eligible for inclusion in this review. There are no trials included in this review. Supplemental enteral tube feeding is widely used throughout the world to improve nutritional status in people with cystic fibrosis. The methods mostly used, nasogastric or gastrostomy feeding, are invasive, expensive, and may have a negative effect on self-esteem and body image. Reported use of enteral tube feeding suggests that it results in nutritional and respiratory improvement and it is disappointing that their efficacy has not been fully assessed by randomised controlled trials. With the more frequent recommendations to use enteral tube feeding as an early rather than a late intervention, this systematic review identifies the need for a multicentre, randomised controlled trial assessing both efficacy and possible

  4. Randomized clinical trial of pigtail catheter versus chest tube in injured patients with uncomplicated traumatic pneumothorax.

    PubMed

    Kulvatunyou, N; Erickson, L; Vijayasekaran, A; Gries, L; Joseph, B; Friese, R F; O'Keeffe, T; Tang, A L; Wynne, J L; Rhee, P

    2014-01-01

    Small pigtail catheters appear to work as well as the traditional large-bore chest tubes in patients with traumatic pneumothorax, but it is not known whether the smaller pigtail catheters are associated with less tube-site pain. This study was conducted to compare tube-site pain following pigtail catheter or chest tube insertion in patients with uncomplicated traumatic pneumothorax. This prospective randomized trial compared 14-Fr pigtail catheters and 28-Fr chest tubes in patients with traumatic pneumothorax presenting to a level I trauma centre from July 2010 to February 2012. Patients who required emergency tube placement, those who refused and those who could not respond to pain assessment were excluded. Primary outcomes were tube-site pain, as assessed by a numerical rating scale, and total pain medication use. Secondary outcomes included the success rate of pneumothorax resolution and insertion-related complications. Forty patients were enrolled. Baseline characteristics of 20 patients in the pigtail catheter group were similar to those of 20 patients in the chest tube group. No patient had a flail chest or haemothorax. Pain scores related to chest wall trauma were similar in the two groups. Patients with a pigtail catheter had significantly lower mean(s.d.) tube-site pain scores than those with a chest tube, at baseline after tube insertion (3.2(0.6) versus 7.7(0.6); P < 0.001), on day 1 (1.9(0.5) versus 6.2(0.7); P < 0.001) and day 2 (2.1(1.1) versus 5.5(1.0); P = 0.040). The decreased use of pain medication associated with pigtail catheter was not significantly different. The duration of tube insertion, success rate and insertion-related complications were all similar in the two groups. For patients with a simple, uncomplicated traumatic pneumothorax, use of a 14-Fr pigtail catheter is associated with reduced pain at the site of insertion, with no other clinically important differences noted compared with chest tubes. NCT01537289 (http

  5. An anatomically sound surgical simulation model for myringotomy and tympanostomy tube insertion.

    PubMed

    Hong, Paul; Webb, Amanda N; Corsten, Gerard; Balderston, Janet; Haworth, Rebecca; Ritchie, Krista; Massoud, Emad

    2014-03-01

    Myringotomy and tympanostomy tube insertion (MT) is a common surgical procedure. Although surgical simulation has proven to be an effective training tool, an anatomically sound simulation model for MT is lacking. We developed such a model and assessed its impact on the operating room performance of senior medical students. Prospective randomized trial. A randomized single-blind controlled study of simulation training with the MT model versus no simulation training. Each participant was randomized to either the simulation model group or control group, after performing an initial MT procedure. Within two weeks of the first procedure, the students performed a second MT. All procedures were performed on real patients and rated with a Global Rating Scale by two attending otolaryngologists. Time to complete the MT was also recorded. Twenty-four senior medical students were enrolled. Control and intervention groups did not differ at baseline on their Global Rating Scale score or time to complete the MT procedure. Following simulation training, the study group received significantly higher scores (P=.005) and performed the MT procedure in significantly less time (P=.034). The control group did not improve their performance scores (P>.05) or the time to complete the procedure (P>.05). Our surgical simulation model shows promise for being a valuable teaching tool for MT for senior medical students. Such anatomically appropriate physical simulators may benefit teaching of junior trainees. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Single Port Laparoscopic Gastrostomy: description of a technique and initial experience.

    PubMed

    Palermo, Mariano; Domínguez, Mario Luis; Acquafresca, Pablo; Duza, Guillermo; Giménez, Mariano

    2015-12-01

    Since the first classic descriptions of surgical gastrostomies for feeding by supra-umbilical medial incisions, patients were operated under general anesthesia, with prolonged time of surgery; these were patients in poor health status, undernourished due to inadequate intake or to neurological or tumor involvement, with prolonged hospitalization, both for the recovery of the intestinal motility as well as for the recovery of post-surgical wounds. Therefore, we describe a new minimally invasive technique as an alternative to the percutaneous or endoscopic gastrostomy, in patients where we are not allowed to place a nasogastric tube to insufflate the stomach. This is mostly seen in patients with tumors, which cause obstruction. Between July 2012 and June 2013, 8 patients underwent a single port laparoscopic gastrostomy. Five were females, mean age: 77 years (range: 67-87). In all the patients, it was impossible to place a nasogastric tube, due to obstructive tumor. The mean time of the procedure was 45 minutes. Seven patients underwent tolerance of dextrose 10% through the catheter after 12 hours and one 24 hours after the procedures. Enteral feeding was indicated after the dextrose 10% tolerance was performed. No complications related to the procedure were observed. Currently, the gold standard technique to perform a gastrostomy is the percutaneous or endoscopic approach. In patients with head and neck tumors, when it is not possible to insert a nasogastric tube to insufflate the stomach, a laparoscopic gastrostomy would be indicated. We describe a new technique, step by step, to perform less invasive laparoscopic surgery by a single port laparoscopic gastrostomy. The diameter created is the same as the one performed with an open technique, but in this case, with a minimally invasive approach, that allows us to start feeding the patient with a high quality of feeding, because of the wider lumen.

  7. Conventional versus pigtail chest tube-are they similar for treatment of malignant pleural effusions?

    PubMed

    Mendes, Maria Aurora; China Pereira, Nuno; Ribeiro, Carla; Vanzeller, Manuela; Shiang, Teresa; Gaio, Rita; Campainha, Sérgio

    2018-08-01

    The optimal chest tube type and size for drainage and chemical pleurodesis of malignant pleural effusions remains controversial. This retrospective study was conducted to compare the efficacy of conventional versus pigtail chest tube in the treatment of malignant pleural effusions. Patients submitted to chest tube drainage and slurry talc pleurodesis due to malignant pleural effusion in our pulmonology ward from 2012 to 2016 were eligible. According to the type of chest tube, they were divided into two groups: group I-conventional chest tube and group II-pigtail chest tube. Number of deaths, recurrence of malignant pleural effusion, and timelines associated with the procedures were reviewed and compared between groups. Out of the 61 included patients, 46 (75.4%) were included in group I and 15 (24.6%) in group II. Only one patient had pigtail chest tube obstruction, with posterior insertion of conventional chest tube. Death during hospital stay and up to 3 months, recurrence at 4 weeks, total duration of hospital stay, time from chest tube insertion to pleurodesis, and time from chest tube insertion to removal were not significantly different between the two groups (all p > 0.05). These findings suggest that pigtail chest tube can be an alternative on palliation, with no compromise in pleurodesis performance.

  8. [Prehospital airway management of laryngeal tubes. Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?].

    PubMed

    Dengler, V; Wilde, P; Byhahn, C; Mack, M G; Schalk, R

    2011-02-01

    Laryngeal tubes (LT) are increasingly being used for emergency airway management. This article reports on two patients in whom out-of-hospital intubation with a single-lumen LT was associated with massive pulmonary aspiration in one patient and gastric overinflation in the other. In both cases peak inspiratory pressures exceeded the LT leak pressure of approximately 35 mbar. This resulted in gastric inflation and decreased pulmonary compliance and increased inspiratory pressure further, thereby creating a vicious circle. It is therefore recommended that laryngeal tube suction (LTS) should be used in all cases of emergency airway management and a gastric drain tube be inserted through the dedicated second lumen. Apart from gastric overinflation, incorrect LT/LTS placement must be detected and immediately corrected, e.g. in cases of difficult or impossible gastric tube placement, permanent drainage of air from the gastric tube, decreasing minute ventilation or an ascending capnography curve.

  9. The single chest tube versus double chest tube application after pulmonary lobectomy: A systematic review and meta-analysis.

    PubMed

    Zhang, Xuefei; Lv, Desheng; Li, Mo; Sun, Ge; Liu, Changhong

    2016-12-01

    Draining of the chest cavity with two chest tubes after pulmonary lobectomy is a common practice. The objective of this study was to evaluate whether using two tubes after a pulmonary lobectomy is more effective than using a single tube. We performed a meta-analysis of five randomized studies that compared the single chest tube with double chest tube application after pulmonary lobectomy. The primary end-point was amount of drainage and duration of chest tube drainage. The secondary end-points were the patient's numbers of new drain insertion after operation, hospital stay after operation, the patient's numbers of subcutaneous emphysema after operation, the patient's numbers of residual pleural air space, pain score, the number of patients who need thoracentesis, and cost. Five randomized controlled trials totaling 502 patients were included. Meta-analysis results are as follows: There were statistically significant differences in amount of drainage (risk ratio [RR] = -0.15; 95% confidence interval [CI] = -3.17, -0.12, P = 0. 03), duration of chest tube drainage (RR = -0.43; 95% CI = -0.57, -0.19, P = 0.02), pain score (P < 0.05). Compared with patients receiving the double chest tube group, there were no statistically significant differences between the two groups with regard to the patient's numbers of new drain insertion after operation. Compared with the double chest tube, the single chest tube significantly decreases amount of drainage, duration of chest tube drainage, pain score, the number of patients who need thoracentesis, and cost. Although there is convincing evidence to confirm the results mentioned herein, they still need to be confirmed by large-sample, multicenter, randomized, controlled trials.

  10. Ventilation tube insertion simulation: a literature review and validity assessment of five training models.

    PubMed

    Mahalingam, S; Awad, Z; Tolley, N S; Khemani, S

    2016-08-01

    The objective of this study was to identify and investigate the face and content validity of ventilation tube insertion (VTI) training models described in the literature. A review of literature was carried out to identify articles describing VTI simulators. Feasible models were replicated and assessed by a group of experts. Postgraduate simulation centre. Experts were defined as surgeons who had performed at least 100 VTI on patients. Seventeen experts were participated ensuring sufficient statistical power for analysis. A standardised 18-item Likert-scale questionnaire was used. This addressed face validity (realism), global and task-specific content (suitability of the model for teaching) and curriculum recommendation. The search revealed eleven models, of which only five had associated validity data. Five models were found to be feasible to replicate. None of the tested models achieved face or global content validity. Only one model achieved task-specific validity, and hence, there was no agreement on curriculum recommendation. The quality of simulation models is moderate and there is room for improvement. There is a need for new models to be developed or existing ones to be refined in order to construct a more realistic training platform for VTI simulation. © 2015 John Wiley & Sons Ltd.

  11. Eddy current measurement of tube element spacing

    DOEpatents

    Latham, Wayne Meredith; Hancock, Jimmy Wade; Grut, Jayne Marie

    1998-01-01

    A method of electromagnetically measuring the distance between adjacent tube elements in a heat exchanger. A cylindrical, high magnetic permeability ferrite slug is placed in the tube adjacent the spacing to be measured. A bobbin or annular coil type probe operated in the absolute mode is inserted into a second tube adjacent the spacing to be measured. From prior calibrations on the response of the eddy current coil, the signals from the coil, when sensing the presence of the ferrite slug, are used to determine the spacing between the tubes.

  12. Parents' attitudes toward oral rehydration therapy in children with mild-to-moderate dehydration.

    PubMed

    Nir, Vered; Nadir, Erez; Schechter, Yaffa; Kline-Kremer, Adi

    2013-01-01

    According to current guidelines, the first line of treatment for mild-to-moderate dehydration is oral rehydration; the second line is rehydration through a nasogastric tube. Both methods are widely underused. This study was conducted to evaluate parents' attitudes towards rehydration methods used in pediatric emergency departments. 100 questionnaires were distributed to parents of children who visited emergency room due to gastroenteritis and suspected dehydration. 75 of the parents expected their child to get IV fluids. 49 of them would refuse to consider oral rehydration. 75 of the parents would refuse to consider insertion of nasogastric tube. Parents whose children were previously treated intravenously tended to be less likely to agree to oral treatment. Parents were more prone to decline oral rehydration if the main measurement of dehydration was the child's clinical appearance, clinical appearance with vomiting, or child's refusal to drink and were more likely to agree if the main measurement was diarrhea, diarrhea with clinical appearance, or clinical personnel opinion. This is the first study to examine parents' expectations. We found that in the majority of cases, parents' expectations contradict current guidelines. Efforts should be taken to educate parents in order to allow full implementation of the guidelines.

  13. Treatment of acute decompensation of maple syrup urine disease in adult patients with a new parenteral amino-acid mixture.

    PubMed

    Servais, A; Arnoux, J B; Lamy, C; Hummel, A; Vittoz, N; Katerinis, I; Bazzaoui, V; Dubois, S; Broissand, C; Husson, M C; Berleur, M P; Rabier, D; Ottolenghi, C; Valayannopoulos, V; de Lonlay, P

    2013-11-01

    Acute decompensation of maple syrup urine disease (MSUD) is usually treated by enteral feeding with an amino-acid mixture without leucine (Leu), valine or isoleucine. However, its administration is ineffective in cases of gastric intolerance and some adult patients refuse enteral feeding via a nasogastric tube. We developed a new parenteral amino-acid mixture for patients with MSUD. Seventeen decompensation episodes in four adult patients with MSUD treated with a parenteral amino-acid mixture (group P) were compared to 18 previous episodes in the same patients treated by enteral feeding (group E). The mean Leu concentration at presentation was similar in the groups P and E (1196.9 μmol/L and 1212.2 μmol/L, respectively). The mean decrease in the Leu concentration during the first 3 days of hospitalisation was significantly higher in group P than group E (p = 0.0026); there were no side effects. The mean duration of hospitalisation was similar (4 vs. 4.5 days, p = NS). No patient in group P deteriorated whereas one patient in group E required dialysis. This new parenteral amino-acid mixture is safe and allows efficient Leu concentration decrease during acute MSUD decompensation episodes in adults. Its use avoids the need for nasogastric tube insertion.

  14. Transfer of adult Strongylus vulgaris via stomach tube.

    PubMed

    Hofing, G L; Bennett, D G

    1983-10-01

    Patent infections with Strongylus vulgaris were established in 6 of 8 helminth-free ponies given 41 to 101 adult worms via nasogastric tube. The parasites were removed from the cecum and ventral colon and transferred within 1 to 2 hours of the death of the donor horses. Eggs were found in the feces of the recipients in 2 or 3 days; egg counts reached maximum, 28 eggs per gram of feces, at 4 weeks after ponies were inoculated. In 6 ponies euthanatized 3 to 7 weeks after parasitic transfers were done, 28% of the inoculated worms were found alive at necropsy. A 7th pony was maintained as a donor for establishing infections for chemotherapy trials and, although never passing more than 6 eggs per gram of feces, shed infective larvae over a period of 2 years.

  15. Unnecessary gastric decompression in distal elective bowel anastomoses in children: a randomized study.

    PubMed

    Davila-Perez, Roberto; Bracho-Blanchet, Eduardo; Tovilla-Mercado, Jose Manuel; Hernandez-Plata, Jose Alejandro; Reyes-Lopez, Alfonso; Nieto-Zermeño, Jaime

    2010-05-01

    The goal of this study was to investigate the role of nasogastric drainage in preventing postoperative complications in children with distal elective bowel anastomosis. Nasogastric drainage has been used as a routine measure after gastrointestinal surgery in children and adults to hasten bowel function, prevent postoperative complications, and shorten hospital stay. However, there has been no study that shows in a scientific manner the benefit of nasogastric drainage in children. We performed a clinical, controlled, randomized trial comprising 60 children who underwent distal elective bowel anastomoses and compared postoperative complications between a group with nasogastric tube in place (n = 29) and one without it (n = 31). Demographic data and diagnoses were comparable in both groups (P = NS). No anastomotic leaks or enterocutaneous fistulae were found in any patient. There were no significant differences between the two groups with respect to abdominal distension, infection, or hospital stay. Only one patient in the experimental group required placement of the nasogastric tube due to persistent abdominal distension (3.2%). The routine use of nasogastric drainage after distal elective intestinal surgery in children can be eliminated. Its use should depend on the individual patient's situation.

  16. Starter for inductively coupled plasma tube

    DOEpatents

    Hull, Donald E.; Bieniewski, Thomas M.

    1988-01-01

    A starter assembly is provided for use with an inductively coupled plasma (ICP) tube to reliably initate a plasma at internal pressures above about 30 microns. A conductive probe is inserted within the inductor coil about the tube and insulated from the tube shield assembly. A capacitive circuit is arranged for momentarily connecting a high voltage radio-frequency generator to the probe while simultaneously energizing the coil. When the plasma is initiated the probe is disconnected from the generator and electrically connected to the shield assembly for operation.

  17. Starter for inductively coupled plasma tube

    DOEpatents

    Hull, D.E.; Bieniewski, T.M.

    1988-08-23

    A starter assembly is provided for use with an inductively coupled plasma (ICP) tube to reliably initiate a plasma at internal pressures above about 30 microns. A conductive probe is inserted within the inductor coil about the tube and insulated from the tube shield assembly. A capacitive circuit is arranged for momentarily connecting a high voltage radio-frequency generator to the probe while simultaneously energizing the coil. When the plasma is initiated the probe is disconnected from the generator and electrically connected to the shield assembly for operation. 1 fig.

  18. Blind bedside postpyloric placement of spiral tube as rescue therapy in critically ill patients: a prospective, tricentric, observational study.

    PubMed

    Lv, Bo; Hu, Linhui; Chen, Lifang; Hu, Bei; Zhang, Yanlin; Ye, Heng; Sun, Cheng; Zhang, Xiunong; Lan, Huilan; Chen, Chunbo

    2017-09-26

    Various special techniques for blind bedside transpyloric tube placement have been introduced into clinical practice. However, transpyloric spiral tube placement facilitated by a blind bedside method has not yet been reported. The objective of this prospective study was to evaluate the safety and efficiency of blind bedside postpyloric placement of a spiral tube as a rescue therapy subsequent to failed spontaneous transpyloric migration in critically ill patients. This prospective, tricentric, observational study was conducted in the intensive care units (ICUs) of three tertiary hospitals. A total of 127 consecutive patients with failed spontaneous transpyloric spiral tube migration despite using prokinetic agents and still required enteral nutrition for more than 3 days were included. The spiral tube was inserted postpylorically using the blind bedside technique. All patients received metoclopramide intravenously prior to tube insertion. The exact tube tip position was determined by radiography. The primary efficacy endpoint was the success rate of postpyloric spiral tube placement. Secondary efficacy endpoints were success rate of a spiral tube placed in the third portion of the duodenum (D3) or beyond, success rate of placement in the proximal jejunum, time to insertion, length of insertion, and number of attempts. Safety endpoints were metoclopramide-related and major adverse tube-associated events. In 81.9% of patients, the spiral feeding tubes were placed postpylorically; of these, 55.1% were placed in D3 or beyond and 33.9% were placed in the proximal jejunum, with a median time to insertion of 14 min and an average number of attempts of 1.4. The mean length of insertion was 95.6 cm. The adverse event incidence was 26.0%, and no serious adverse event was observed. Blind bedside postpyloric placement of a spiral tube, as a rescue therapy subsequent to failed spontaneous transpyloric migration in critically ill patients, is safe and effective. This

  19. [Role of the small intestinal decompression tube and Gastrografin in the treatment of early postoperative inflammatory small bowel obstruction].

    PubMed

    Li, Wei; Li, Zhixia; An, Dali; Liu, Jing; Zhang, Xiaohu

    2014-03-01

    To evaluate the role of the small intestinal decompression tube (SIDT) and Gastrografin in the treatment of early postoperative inflammatory small bowel obstruction (EPISBO). Twelve patients presented EPISBO after abdominal surgery in our department from April 2011 to July 2012. Initially, nasogastric tube decompression and other conventional conservative treatment were administrated. After 14 days, obstruction symptom improvement was not obvious, then the SIDT was used. At the same time, Gastrografin was injected into the small bowel through the SIDT in order to demonstrate the site of obstruction of small bowel and its efficacy. In 11 patients after this management, obstruction symptoms disappeared, bowel function recovered within 3 weeks, and oral feeding occurred gradually. Another patient did not pass flatus after 4 weeks and was reoperated. After postoperative follow-up of 6 months, no case relapsed with intestinal obstruction. For severe and long course of early postoperative inflammatory intestinal obstruction, intestinal decompression tube plus Gastrografin is safe and effective, and can avoid unnecessary reoperation.

  20. The practice of gastrostomy tube placement across a Canadian regional health authority.

    PubMed

    Pruthi, Deepak; Duerksen, Donald R; Singh, Harminder

    2010-07-01

    We sought to conduct an assessment of the practice of gastrostomy (G) tube placement across an entire city, which would reflect usual clinical care as compared with referral center practice. We reviewed and retrospectively extracted data from patient records for all percutaneous endoscopic G (PEG) and radiological percutaneous G (RPG) tube placements at six Winnipeg hospitals between 1 April 2005 and 31 March 2007. A total of 418 patients had G tubes (376 PEG, 42 RPG) inserted during the study period. The most common indications were cerebrovascular accidents (25%), head and neck cancer (23%), and head trauma (10%). The position of the external bolster was not documented in 38% of patients. The median time to the first complication was 10 days, initiation of feeding was 48 hours, and tube removal was 40 days. Complications developed in 102 (24%) patients. Patients with RPG tubes had more infections and were less likely to receive prophylactic antibiotics (P<0.001). In multivariate analysis, complications were more likely to occur in patients with RPG tubes and after insertions by lowest procedure volume physicians. Overall mortality was 12% within 30 days of G-tube placement. Death of one patient was directly related to peritonitis after G-tube insertion. In usual clinical practice, there is an underuse of prophylactic antibiotics and a delay in the institution of nutritional support after G-tube placement. A small but significant proportion of patients may develop major complications, with associated risk of mortality. The higher complication rate after procedures performed by lowest volume physicians needs further evaluation.

  1. Vibration analysis of the tympanic membrane with a ventilation tube and a perforation by holography

    NASA Astrophysics Data System (ADS)

    Maeta, Manabu; Kawakami, Shinichiro; Ogawara, Toshiaki; Masuda, Yu

    1991-08-01

    For severe otitis media with effusion, insertion of a ventilation tube is performed for the purpose of ventilation of the middle ear cavity and normalization of the eustachian tubular function and middle ear mucosa. The ventilation tube is left in place for as long as several months or even a few years. However, the influence of the indwelling tube on vibration of the tympanic membrane is unknown. Therefore, the authors observed the influence by means of time-averaged holography using human tympanic membranes. The following results were obtained. After insertion of a ventilation tube, vibration pattern of the tympanic membrane was not obviously changed, but the vibration amplitude of the tympanic membrane was decreased, especially at 500 Hz. Generally speaking, the change caused by insertion of a ventilation tube was very small. Also, the vibration pattern of perforated tympanic membrane was not changed, but the vibration amplitude of perforated tympanic membrane was decreased at the low frequency area.

  2. Postoperative ileus-related morbidity profile in patients treated with alvimopan after bowel resection.

    PubMed

    Wolff, Bruce G; Weese, James L; Ludwig, Kirk A; Delaney, Conor P; Stamos, Michael J; Michelassi, Fabrizio; Du, Wei; Techner, Lee

    2007-04-01

    Postoperative ileus (POI), an interruption of coordinated bowel motility after operation, is exacerbated by opioids used to manage pain. Alvimopan, a peripherally acting mu-opioid receptor antagonist, accelerated gastrointestinal (GI) recovery after bowel resection in randomized, double-blind, placebo-controlled, multicenter phase III POI trials. The effect of alvimopan on POI-related morbidity for patients who underwent bowel resection was evaluated in a post-hoc analysis. Incidence of POI-related postoperative morbidity (postoperative nasogastric tube insertion or POI-related prolonged hospital stay or readmission) was analyzed in four North American trials for placebo or alvimopan 12 mg administered 30 minutes or more preoperatively and twice daily postoperatively until hospital discharge (7 or fewer postoperative days). GI-related adverse events and opioid consumption were summarized for each treatment. Estimations of odds ratios of alvimopan to placebo and number needed to treat (NNT) to prevent one patient from experiencing an event of POI-related morbidity were derived from the analysis. Patients receiving alvimopan 12 mg were less likely to experience POI-related morbidity than patients receiving placebo (odds ratio = 0.44, p < 0.001). Fewer patients receiving alvimopan (alvimopan, 7.6%; placebo, 15.8%; NNT = 12) experienced POI-related morbidity. There was a lower incidence of postoperative nasogastric tube insertion, and other GI-related adverse events on postoperative days 3 to 6 in the alvimopan group than the placebo group. Opioid consumption was comparable between groups. Alvimopan 12 mg was associated with reduced POI-related morbidity compared with placebo, without compromising opioid-based analgesia in patients undergoing bowel resection. Relatively low NNTs are clinically meaningful and reinforce the potential benefits of alvimopan for the patient and health care system.

  3. Establishing Decision Trees for Predicting Successful Postpyloric Nasoenteric Tube Placement in Critically Ill Patients.

    PubMed

    Chen, Weisheng; Sun, Cheng; Wei, Ru; Zhang, Yanlin; Ye, Heng; Chi, Ruibin; Zhang, Yichen; Hu, Bei; Lv, Bo; Chen, Lifang; Zhang, Xiunong; Lan, Huilan; Chen, Chunbo

    2016-08-31

    Despite the use of prokinetic agents, the overall success rate for postpyloric placement via a self-propelled spiral nasoenteric tube is quite low. This retrospective study was conducted in the intensive care units of 11 university hospitals from 2006 to 2016 among adult patients who underwent self-propelled spiral nasoenteric tube insertion. Success was defined as postpyloric nasoenteric tube placement confirmed by abdominal x-ray scan 24 hours after tube insertion. Chi-square automatic interaction detection (CHAID), simple classification and regression trees (SimpleCart), and J48 methodologies were used to develop decision tree models, and multiple logistic regression (LR) methodology was used to develop an LR model for predicting successful postpyloric nasoenteric tube placement. The area under the receiver operating characteristic curve (AUC) was used to evaluate the performance of these models. Successful postpyloric nasoenteric tube placement was confirmed in 427 of 939 patients enrolled. For predicting successful postpyloric nasoenteric tube placement, the performance of the 3 decision trees was similar in terms of the AUCs: 0.715 for the CHAID model, 0.682 for the SimpleCart model, and 0.671 for the J48 model. The AUC of the LR model was 0.729, which outperformed the J48 model. Both the CHAID and LR models achieved an acceptable discrimination for predicting successful postpyloric nasoenteric tube placement and were useful for intensivists in the setting of self-propelled spiral nasoenteric tube insertion. © 2016 American Society for Parenteral and Enteral Nutrition.

  4. Establishing Decision Trees for Predicting Successful Postpyloric Nasoenteric Tube Placement in Critically Ill Patients.

    PubMed

    Chen, Weisheng; Sun, Cheng; Wei, Ru; Zhang, Yanlin; Ye, Heng; Chi, Ruibin; Zhang, Yichen; Hu, Bei; Lv, Bo; Chen, Lifang; Zhang, Xiunong; Lan, Huilan; Chen, Chunbo

    2018-01-01

    Despite the use of prokinetic agents, the overall success rate for postpyloric placement via a self-propelled spiral nasoenteric tube is quite low. This retrospective study was conducted in the intensive care units of 11 university hospitals from 2006 to 2016 among adult patients who underwent self-propelled spiral nasoenteric tube insertion. Success was defined as postpyloric nasoenteric tube placement confirmed by abdominal x-ray scan 24 hours after tube insertion. Chi-square automatic interaction detection (CHAID), simple classification and regression trees (SimpleCart), and J48 methodologies were used to develop decision tree models, and multiple logistic regression (LR) methodology was used to develop an LR model for predicting successful postpyloric nasoenteric tube placement. The area under the receiver operating characteristic curve (AUC) was used to evaluate the performance of these models. Successful postpyloric nasoenteric tube placement was confirmed in 427 of 939 patients enrolled. For predicting successful postpyloric nasoenteric tube placement, the performance of the 3 decision trees was similar in terms of the AUCs: 0.715 for the CHAID model, 0.682 for the SimpleCart model, and 0.671 for the J48 model. The AUC of the LR model was 0.729, which outperformed the J48 model. Both the CHAID and LR models achieved an acceptable discrimination for predicting successful postpyloric nasoenteric tube placement and were useful for intensivists in the setting of self-propelled spiral nasoenteric tube insertion. © 2016 American Society for Parenteral and Enteral Nutrition.

  5. [A clinical study using octreotide in relieving gastrointestinal symptoms due to bowel obstruction in a terminally ill cancer patient].

    PubMed

    Shima, Yasuo; Yamaguchi, Kensei; Miyata, Yoshinori; Hyodo, Ichinosuke; Yagi, Yasuo; Honke, Yoshifumi

    2004-09-01

    Terminally ill cancer patients with complicated bowel obstructions often have poor quality of life (QOL) due to gastrointestinal symptoms such as nausea and vomiting. Many of these patients are inoperable because of poor general conditions, and half of these patients can't be managed by conventional antiemetics. There are many reports indicating octreotide is effective for these patients. In the present study, 13 patients (5 patients without a nasogastric tube and 8 patients with) were administered octreotide at 300 microg/day by 24 hours continuous subcutaneous infusion. Among the effectively evaluable 10 cases, 6 cases (60.0%) were assessed as effective according to the efficacy criteria based on the JCOG toxicity scale. In the 6 cases who had nasogastric tubes, the nasogastric aspirates decreased from 890 ml (550-1,950) to 480 ml (180-1,790). Vomiting was successfully controlled after the removals of nasogastric tubes in 4 out of 6 cases (66.7%), regarding safety, 2 out of 13 cases (15.4%) showed an excess of liver enzymes but no clinically suspected adverse effect was observed. Octreotide is effective and well tolerated in terminally ill cancer patients with malignant bowel obstruction.

  6. Students insert the laryngeal tube quicker and more often successful than the esophageal-tracheal combitube in a manikin.

    PubMed

    Hüter, Lars; Schwarzkopf, Konrad; Rödiger, Jörg; Preussler, Niels P; Schreiber, Torsten

    2009-08-01

    Endotracheal intubation remains the standard of airway management. Because intubation skills are difficult to acquire, for medical students teaching of easier to learn techniques should be considered. We retrospectively analyzed data that were collected in a University teaching facility. 264 medical students were taught how to use laryngeal tube (LT) and Esophageal Tracheal Combitube((R)) (ETC) in a manikin. The students underwent one of two different types of extraglottic airway management training consisting of either long lecture (30min) and intensive training (2h) (group IT, n=48), or brief (10min) lecture and 20min of training (group BT, n=216). Both groups underwent a test 6 weeks after training, group IT had an additional test 24h after training. After 24h students in group IT were faster using the LT than the ETC (31.7s+/-2.1 vs. 51.9s+/-5.8, p<0.001). Up to 6 weeks after training students were able to place the LT significantly faster than the ETC in both groups (26.5s+/-2.1 vs. 53.9s+/-5.8 group IT and 43.4s+/-1.6 vs. 103.8s+/-4.4 group BT, p<0.001). At 24h and 6 weeks following intensive training, there was no statistical difference in the time required for insertion of either device. Following different training scenarios in a manikin, students were able to place the LT much faster than the ETC. Even brief training was sufficient to generate short insertion times for the LT.

  7. A qualitative analysis of how parents assess acute pain in young children

    PubMed Central

    Loopstra, Candice; Herd, David

    2015-01-01

    An accurate and comprehensive pain assessment is crucial for adequate pain management in pre- and early verbal children during painful medical procedures. This study used an inductive approach to explore the processes involved in parental pain assessment and to develop a new model of Parental Assessment of Acute Child Pain. Participants were 19 parents of children aged under 3 years who had previously or were potentially about to experience an intravenous cannula or nasogastric tube insertion. Parental affect regulation, while witnessing their child in acute pain/distress, appeared to be critical to the processes involved in assessing their child’s pain. PMID:28070349

  8. Joining Tubes With Adhesive

    NASA Technical Reports Server (NTRS)

    Bateman, W. A.

    1984-01-01

    Cylindrical tubes joined together, end to end, by method employing adhesive, tapered ends, and spacing wires. Tapered joint between tubular structural elements provides pressure between bonding surfaces during adhesive curing. Spacing wires prevent adhesive from being scraped away when one element inserted in other. Method developed for assembling structural elements made of composite materials.

  9. The impact of a chest tube management protocol on the outcome of trauma patients with tube thoracostomy.

    PubMed

    de Abreu, Emanuelle Maria Sávio; Machado, Carla Jorge; Pastore Neto, Mario; de Rezende Neto, João Baptista; Sanches, Marcelo Dias

    2015-01-01

    to investigate the effect of standardized interventions in the management of tube thoracostomy patients and to assess the independent effect of each intervention. A chest tube management protocol was assessed in a retrospective cohort study. The tube thoracostomy protocol (TTP) was implemented in August 2012, and consisted of: antimicrobial prophylaxis, chest tube insertion in the operating room (OR), admission post chest tube thoracostomy (CTT) in a hospital floor separate from the emergency department (ED), and daily respiratory therapy (RT) sessions post-CTT. The inclusion criteria were, hemodynamic stability, patients between the ages of 15 and 59 years, and injury severity score (ISS) < 17. All patients had isolated injuries to the chest wall, lung, and pleura. During the study period 92 patients were managed according to the standardized protocol. The outcomes of those patients were compared to 99 patients treated before the TTP. Multivariate logistic regression analysis was performed to assess the independent effect of each variable of the protocol on selected outcomes. Demographics, injury severity, and trauma mechanisms were similar among the groups. As expected, protocol compliance increased after the implementation of the TTP. There was a significant reduction (p<0.05) in the incidence of retained hemothoraces, empyemas, pneumonias, surgical site infections, post-procedural complications, hospital length of stay, and number of chest tube days. Respiratory therapy was independently linked to significant reduction (p<0.05) in the incidence of seven out of eight undesired outcomes after CTT. Antimicrobial prophylaxis was linked to a significant decrease (p<0.05) in retained hemothoraces, despite no significant (p<0.10) reductions in empyema and surgical site infections. Conversely, OR chest tube insertion was associated with significant (p<0.05) reduction of both complications, and also significantly decreased the incidence of pneumonias. Implementation of

  10. The quality and accuracy of internet information on the subject of ear tubes.

    PubMed

    McKearney, Thomas C; McKearney, Richard M

    2013-06-01

    The World Wide Web is a commonly used source of health information for patients. The objective of this study is to assess the quality and accuracy of information on the internet regarding ear tubes and their insertion. Websites were identified from Google, Yahoo and MSN using the search terms 'myringotomy', 'tympanostomy', 'grommet' and 'ear tubes'. The first 40 consecutive websites from each search engine using each search term were potentially eligible for the study. Quality of information was assessed using the DISCERN instrument and readability using the Flesch Readability Formula and Flesch-Kincaid Grade Level Readability Formula. As the DISCERN instrument is subjective, both authors rated each website. Specific facts related to ear tubes were identified from each website such as the indications for and complications of ear tubes which were evaluated for accuracy and consistency. Of the 480 potentially eligible websites, 84 were included in the study. The mean DISCERN score for all websites was 38.5 (range 18-64) and the mean readability score was 49.4 (range 5.7-71.6). The mean Flesch-Kincaid Grade level was 10.1 (range 6.6-12). Key facts quoted on websites regarding ear tube information such as indications for insertion and complications are very variable. Overall, internet information regarding ear tubes is of mixed quality and the readability is generally low. Certain topics such as the number of patients that require repeat ear tube insertion and advice on bathing and showering with ear tubes were poorly described. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. [How to do - the chest tube drainage].

    PubMed

    Klopp, Michael; Hoffmann, Hans; Dienemann, Hendrik

    2015-03-01

    A chest tube is used to drain the contents of the pleural space to reconstitute the physiologic pressures within the pleural space and to allow the lungs to fully expand. Indications for chest tube placement include pneumothorax, hemothorax, pleural effusion, pleural empyema, and major thoracic surgery. The most appropriate site for chest tube placement is the 4th or 5th intercostal space in the mid- or anterior- axillary line. Attention to technique in placing the chest tube is vital to avoid complications from the procedure. Applying the step-by-step technique presented, placement of a chest tube is a quick and safe procedure. Complications - frequently occurring when the tube is inserted with a steel trocar - include hemothorax, dislocation, lung lacerations, and injury to organs in the thoracic or abdominal cavity." © Georg Thieme Verlag KG Stuttgart · New York.

  12. CONCENTRIC TUBE FUEL ELEMENT SPRING ALIGNMENT SPACER DEVICE

    DOEpatents

    Weems, S.J.

    1963-09-24

    A rib construction for a nuclear-fuel element is described, in which one of three peripherally spaced ribs adjacent to each end of the fuel element is mounted on a radially yielding spring that embraces the fuel element. This spring enables the fuel element to have a good fit with a coolant tube and yet to be easily inserted in and withdrawn from the tube. (AEC)

  13. Tool and process for miniature explosive joining of tubes

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J. (Inventor); Bailey, James W. (Inventor)

    1987-01-01

    A tool and process to be used in the explosive joining of tubes is disclosed. The tool consists of an initiator, a tool form, and a ribbon explosive. The assembled tool is a compact, storable, and safe device suitable for explosive joining of small, lightweight tubes down to 0.20 inch in diameter. The invention is inserted into either another tube or a tube plate. A shim or standoff between the two surfaces to be welded is necessary. Initiation of the explosive inside the tube results in a high velocity, angular collision between the mating surfaces. This collision creates surface melts and collision bonding wherein electron-sharing linkups are formed.

  14. Lidocaine-Prilocaine Cream as Analgesia for IUD Insertion: A Prospective, Randomized, Controlled, Triple Blinded Study

    PubMed Central

    Tavakolian, Samira; Doulabi, Mahbobeh Ahmadi; Baghban, Alireza Akbarzade; Mortazavi, Alireza; Ghorbani, Maryam

    2015-01-01

    Introduction: Copper IUD is a long term and reversible contraception which equals tubal ligation in terms of sterilization. One of the barriers to using this contraception method is the fear and the pain associated with its insertion. Eutectic mixture of local anesthetics (EMLA) 5% is a local anesthetic that contains 25 mg lidocaine and 25 mg of prilocaine per gram. Application of topical analgesic cream to the cervix for laser surgery, hysteroscopy and hysterosalpingography is known Aims: this study aimed to determine the effect of EMLA on IUD insertion pain. Methods: This triple blind clinical trial was conducted on 92 women in a clinic in Hamedan in 2012. After applying the cream on the cervix, pain in three steps, after using Tenaculum, after inserting hystrometr and after inserting IUD and removing IUD insertion tube were assessed with visual analog scale and were compared in EMLA group and placebo group Statistical analysis used to determine and compare the pain of independent t tests, Mann-Whitney U test and repeated measures analysis of variance and chi-square tests to determine the homogeneity of variables and Fisher’s exact test was used Results: Insertion hystrometr was determined as the most painful IUD insertion. The mean pain at step 2 (inserting hystrometr) was (3/11±2/53) in EMLA group, (5/23±2/31) in placebo group. EMLA cream significantly reduced the pain after using tenaculum (P<0/001), pain inserting Hystrometr (P< 0/001) and pain at IUD insertion and removing insertion tube (P< 0/001) Conclusions: Topical Application of EMLA 5% cream as a topical anesthetic on the cervix before insertion IUD reduced the pain during this procedure. PMID:25946948

  15. Ultrasonic airborne insertion loss measurements at normal incidence (L).

    PubMed

    Farley, Jayrin; Anderson, Brian E

    2010-12-01

    Transmission loss and insertion loss measurements of building materials at audible frequencies are commonly made using plane wave tubes or as a panel between reverberant rooms. These measurements provide information for noise isolation control in architectural acoustics and in product development. Airborne ultrasonic sound transmission through common building materials has not been fully explored. Technologies and products that utilize ultrasonic frequencies are becoming increasingly more common, hence the need to conduct such measurements. This letter presents preliminary measurements of the ultrasonic insertion loss levels for common building materials over a frequency range of 28-90 kHz using continuous-wave excitation.

  16. Mediastinal hemorrhage: An evaluation of radiographic manifestations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodring, J.H.; Loh, F.K.; Kryscio, R.J.

    1984-04-01

    Eleven common radiographic signs of mediastinal hemorrhage were evaluated by two observers for the following three patient groups: normal subjects, patients with mediastinal hemorrhage and no arterial injury, and patients with major thoracic arterial injury. Supine chest radiographs were studied in all cases. Four major conclusions can be made based upon these finding. M/C ratio (mediastinal width to chest width), tracheal deviation, left hemothorax, paraspinal line widening, and aorto-pulmonary window opacification do not reliably separate these three groups of patients. The diagnosis of mediastinal hemorrhage may be made if the aortic contour is abnormal or if one of the followingmore » signs is positive: abnormal mediastinal width, apical cap, widening of the right paratracheal stripe, or deviation of the nasogastric tube. Due to interobserver variation, there is good agreement between observers for the following four signs only: transverse mediastinal width, tracheal deviation, nasogastric tube deviation, nasogastric tube deviation, and right paratracheal stripe widening.« less

  17. 76 FR 52961 - Prospective Grant of Exclusive License: Devices for Clearing Mucus From Endotracheal Tubes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-24

    ... invention embodied in: HHS Ref. No. E-061-2004/0 ``Mucus Shaving Apparatus for Endotracheal Tubes''; U.S... endotracheal tube cleaning apparatus which is inserted into the inside of an endotracheal tube to shave away... apparatus with a flexible central tube and an inflatable balloon at its distal end. Affixed to the...

  18. Verifying placement of small-bore feeding tubes: electromagnetic device images versus abdominal radiographs.

    PubMed

    Bryant, Vera; Phang, Jean; Abrams, Kevin

    2015-11-01

    Clinicians are unsure if radiography is needed to confirm correct positioning of feeding tubes inserted with assistance from an electromagnetic system. To compare radiographic reports of feeding tube placement with images generated by an electromagnetic feeding tube placement device. The medical records of 200 consecutive patients who had feeding tubes inserted with assistance from an electromagnetic feeding tube placement device were reviewed retrospectively. Radiographic reports of tube site were compared with images generated by the device. Radiographic evidence of tube sites was available in 188 cases: 184 tubes were located in portions of the gastrointestinal tract. Ninety of the 188 tubes were situated in the optimal site (distal duodenum or jejunum) radiographically. Images generated by the electromagnetic device were available in 176 cases; of these, 52 tubes appeared to end in the expected left lower quadrant. Tubes shown on radiographs to be in other sites also occasionally appeared to end in the left lower quadrant. Nurses using the device did not recognize 4 of the 188 tubes (2.1%) that were inadvertently placed in the lung. No consistent pattern of quadrant distribution was found for tubes positioned in the stomach or proximal duodenum. Images generated by the electromagnetic tube placement device provided inconsistent results regarding tube location. A small percentage of seriously malpositioned tubes were not detected by using the electromagnetic device. These findings do not support eliminating radiographs to confirm correct tube placement following use of an electromagnetic tube placement device. ©2015 American Association of Critical-Care Nurses.

  19. [Percutaneous tubing and drainage for the diagnosis and treatment of malignant pericardial effusion].

    PubMed

    Li, Y; Zhou, J; Zhang, J

    2000-01-01

    To insert a tube into pericardial cavity as an emergent measure of diagnosis and treatment in patients with malignant pericardial effusion. Pericardial puncture was followed by insertion of drainage tube (diameter = 1.8 mm) through the puncture needle. The effusion collected was examined for cancer cells. After drainage, chemotherapeutic agents were administered. Four hours later, drainage was continued for 2 days (< or = 30 ml pericardial fluid drained in 24 hr) and the tube was removed. In 34 cases with malignant pericardial effusion, tube draining was successful to relieve cardiac temponade within 15-60 minutes. Clots were present in 91.2% of the cases and cancer diagnosis was confirmed in all of them. The cytologic diagnosis of effusion was positive in 61.8%, and the cyto-pathologic typing of clots was 81.0%. The difference was statistically significant. When the results of the 2 examinations were put together, the positive rate increased to 94.1%. Tube drainage of malignant pericardial effusion is useful in diagnosis and emergency treatment.

  20. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding.

    PubMed

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-07-07

    To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.

  1. Colorimetric carbon dioxide detector to determine accidental tracheal feeding tube placement.

    PubMed

    Howes, Daniel W; Shelley, Eric S; Pickett, William

    2005-04-01

    To determine the accuracy of colorimetric CO2 detection compared to the reference standard two-step radiological confirmation of feeding tube position. A prospective study was conducted with patients presenting to a 21-bed medical-surgical intensive care unit. An adapter was developed using an endotracheal tube adapter to connect a colorimetric CO2 detector to a feeding tube in an airtight manner. In part I of the study a feeding tube connected to the colorimeter was inserted into the endotracheal tubes of ten ventilated patients to test the device's ability to detect tracheal placement. In part II patients undergoing feeding tube insertion had tube position confirmed with the colorimeter as well as the reference standard two-step x-ray. In phase I the colorimeter correctly identified tracheal placement in all ten patients. In phase II 93/100 procedures ultimately were eligible; the colorimeter had a sensitivity of 0.88 (95% confidence interval: 0.65-1.00) and specificity of 0.99 (0.97-1.00). The device missed one of the eight tracheal placements. Agreement between the colorimeter and two-step x-ray interpretations was excellent (Kappa 0.86; standard error 0.10). We describe a novel, convenient method to confirm esophageal feeding tube placement. The device is easily assembled and inexpensive, but should not be reused. Colorimetric determination of tracheal feeding tube placement with this device has excellent agreement with the reference standard two-step radiological technique.

  2. Esophageal stricture - benign

    MedlinePlus

    Esophageal stricture can be caused by: Gastroesophageal reflux (GERD). Eosinophilic esophagitis. Injuries caused by an endoscope . Long-term use of a nasogastric (NG) tube (tube through the nose into the ...

  3. Tube cutter tool and method of use for coupon removal

    DOEpatents

    Nachbar, H.D.; Etten, M.P. Jr.; Kurowski, P.A.

    1997-05-06

    A tube cutter tool is insertable into a tube for cutting a coupon from a damaged site on the exterior of the tube. Prior to using the tool, the damaged site is first located from the interior of the tube using a multi-coil pancake eddy current test probe. The damaged site is then marked. A fiber optic probe is used to monitor the subsequent cutting procedure which is performed using a hole saw mounted on the tube cutter tool. Prior to completion of the cutting procedure, a drill in the center of the hole saw is drilled into the coupon to hold it in place. 4 figs.

  4. Tube cutter tool and method of use for coupon removal

    DOEpatents

    Nachbar, Henry D.; Etten, Jr., Marvin P.; Kurowski, Paul A.

    1997-01-01

    A tube cutter tool is insertable into a tube for cutting a coupon from a damaged site on the exterior of the tube. Prior to using the tool, the damaged site is first located from the interior of the tube using a multi-coil pancake eddy current test probe. The damaged site is then marked. A fiber optic probe is used to monitor the subsequent cutting procedure which is performed using a hole saw mounted on the tube cutter tool. Prior to completion of the cutting procedure, a drill in the center of the hole saw is drilled into the coupon to hold it in place.

  5. Quality Improvement Initiative to Increase the Use of Nasogastric Hydration in Infants With Bronchiolitis.

    PubMed

    Srinivasan, Mythili; Pruitt, Cassandra; Casey, Erin; Dhaliwal, Keerat; DeSanto, Cori; Markus, Richard; Rosen, Ayelet

    2017-08-01

    Intravenous (IV) hydration is used primarily in children with bronchiolitis at our institution. Because nasogastric (NG) hydration can provide better nutrition, the goal of our quality improvement (QI) initiative was to increase the rate of NG hydration in eligible children 1 to 23 months old with bronchiolitis by 20% over 6 months. We used Plan-Do-Study-Act cycles to increase the use of NG hydration in eligible children. Interventions included educational and system-based changes and sharing parental feedback with providers. Chart reviews were performed to identify the rates of NG hydration, which were plotted over time in a statistical process control p chart. The balancing measure was the rate of complications in children with NG versus IV hydration. Two hundred and ninety-three children who were hospitalized with bronchiolitis needed supplemental hydration during the QI initiative (January 2016-April 2016). Ninety-one children were candidates for NG hydration, and 53 (58%) received NG hydration. The rates of NG hydration increased from a baseline of 0% pre-QI bronchiolitis season (January 2015-April 2015) to 58% during the initiative. There was no aspiration and no accidental placement of the NG tube into a child's airway. Nine patients (17%) in the NG group had a progression of disease requiring nil per os status, and 6 of these were transferred to the PICU whereas none of those in the IV group were transferred to the PICU. Post-QI initiative, the majority of nurses (63%) and physicians (95%) stated that they are more likely to consider NG hydration in children with bronchiolitis. We successfully increased the rates of NG hydration in eligible children with bronchiolitis by using educational and system-based interventions. Copyright © 2017 by the American Academy of Pediatrics.

  6. Vein-style air pumping tube and tire system and method of assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benedict, Robert Leon; Gobinath, Thulasiram; Lin, Cheng-Hsiung

    An air pumping tube and tire system and method of assembling is provided in which a tire groove is formed to extend into a flexing region of a tire sidewall and a complementary air pumping tube inserts into the tire groove. In the green, uncured air pumping tube condition, one or more check valves are assembled into the air pumping tube through access shafts and align with an internal air passageway of the air pumping tube. Plug components of the system enclose the check valves in the air pumping tube and the check valve-containing green air pumping tube is thenmore » cured.« less

  7. Clinics in diagnostic imaging (168).

    PubMed

    Lai, Yusheng Keefe; Mahmood, Rameysh Danovani

    2016-05-01

    A 16-year-old Chinese male patient presented with constipation lasting five days, colicky abdominal pain, lethargy, weakness and body aches. He was able to pass flatus. Abdominal radiography showed a distended stomach causing inferior displacement of the transverse colon. Computed tomography revealed a dilated oesophagus, stomach and duodenum up to its third portion, with a short aortomesenteric distance and narrow angle. There was also consolidation in the lungs bilaterally. Based on the constellation of clinical and imaging findings, a diagnosis of superior mesenteric artery syndrome complicated by aspiration pneumonia was made. The patient was subsequently started on intravenous hydration, nasogastric tube aspiration and antibiotics. Following stabilisation of his acute condition, a nasojejunal feeding tube was inserted and a feeding plan was implemented to promote weight gain. The clinical presentation, differentials, diagnosis and treatment of superior mesenteric artery syndrome are discussed. Copyright: © Singapore Medical Association.

  8. Tube Thoracostomy: Complications and Its Management

    PubMed Central

    Kesieme, Emeka B.; Dongo, Andrew; Ezemba, Ndubueze; Irekpita, Eshiobo; Jebbin, Nze; Kesieme, Chinenye

    2012-01-01

    Background. Tube thoracostomy is widely used throughout the medical, surgical, and critical care specialities. It is generally used to drain pleural collections either as elective or emergency. Complications resulting from tube thoracostomy can occasionally be life threatening. Aim. To present an update on the complications and management of complications of tube thoracostomy. Methods. A review of the publications obtained from Medline search, medical libraries, and Google on tube thoracostomy and its complications was done. Results. Tube thoracostomy is a common surgical procedure which can be performed by either the blunt dissection technique or the trocar technique. Complication rates are increased by the trocar technique. These complications have been broadly classified as either technical or infective. Technical causes include tube malposition, blocked drain, chest drain dislodgement, reexpansion pulmonary edema, subcutaneous emphysema, nerve injuries, cardiac and vascular injuries, oesophageal injuries, residual/postextubation pneumothorax, fistulae, tumor recurrence at insertion site, herniation through the site of thoracostomy, chylothorax, and cardiac dysrhythmias. Infective complications include empyema and surgical site infection. Conclusion. Tube thoracostomy, though commonly performed is not without risk. Blunt dissection technique has lower risk of complications and is hence recommended. PMID:22028963

  9. Impact Deformation of Thin-Walled Circular Tube Filled with Aluminum Foam in Lateral Compression

    NASA Astrophysics Data System (ADS)

    Kobayashi, Hidetoshi; Horikawa, Keitaro; Ogawa, Kinya; Hori, Masahiro

    In this study, the impact deformation of thin-walled circular tubes filled with aluminum foam in lateral compression was investigated using a special load cell for long time measurement and a high-speed video camera to check the displacement of specimens. It was found that the absorbed energy up to the deformation of 60% of the specimen diameter obtained from impact tests is greater than that obtained in static tests, because of strain rate dependency of aluminum foam. The loaddisplacement curve of circular tubes with aluminum foam just inserted was consistent with the sum of the curves individually obtained. In both dynamic and static tests, however, the load of the tube with the foam inserted and glued by adhesive resin became larger than the sum of the individual loads, because of the interaction between circular tubes and aluminum foam cores.

  10. Interventions for children with ear discharge occurring at least two weeks following grommet (ventilation tube) insertion.

    PubMed

    Venekamp, Roderick P; Javed, Faisal; van Dongen, Thijs Ma; Waddell, Angus; Schilder, Anne Gm

    2016-11-17

    Ear discharge (otorrhoea) is common in children with grommets (ventilation/tympanostomy tubes); the proportion of children developing discharge ranges from 25% to 75%. The most common treatment strategies include oral broad-spectrum antibiotics, antibiotic eardrops or those containing a combination of antibiotic(s) and a corticosteroid, and initial observation. Important drivers for one strategy over the other are concerns over the side effects of oral antibiotics and the potential ototoxicity of antibiotic eardrops. To assess the benefits and harms of current treatment strategies for children with ear discharge occurring at least two weeks following grommet (ventilation tube) insertion. The Cochrane ENT Information Specialist searched the ENT Trials Register, CENTRAL (2016, Issue 5), multiple databases and additional sources for published and unpublished trials (search date 23 June 2016). Randomised controlled trials comparing at least two of the following: oral antibiotics, oral corticosteroids, antibiotic eardrops (with or without corticosteroid), corticosteroid eardrops, microsuction cleaning of the ear canal, saline rinsing of the ear canal, placebo or no treatment. The main comparison of interest was antibiotic eardrops (with or without corticosteroid) versus oral antibiotics. We used the standard methodological procedures expected by Cochrane. Primary outcomes were: proportion of children with resolution of ear discharge at short-term follow-up (less than two weeks), adverse events and serious complications. Secondary outcomes were: proportion of children with resolution of ear discharge at intermediate- (two to four weeks) and long-term (four to 12 weeks) follow-up, proportion of children with resolution of ear pain and fever at short-term follow-up, duration of ear discharge, proportion of children with chronic ear discharge, ear discharge recurrences, tube blockage, tube extrusion, health-related quality of life and hearing. We used GRADE to assess the

  11. A prospective randomised trial comparing nasogastric with intravenous hydration in children with bronchiolitis (protocol) The comparative rehydration in bronchiolitis study (CRIB)

    PubMed Central

    2010-01-01

    Background Bronchiolitis is the most common reason for admission of infants to hospital in developed countries. Fluid replacement therapy is required in about 30% of children admitted with bronchiolitis. There are currently two techniques of fluid replacement therapy that are used with the same frequency-intravenous (IV) or nasogastric (NG). The evidence to determine the optimum route of hydration therapy for infants with bronchiolitis is inadequate. This randomised trial will be the first to provide good quality evidence of whether nasogastric rehydration (NGR) offers benefits over intravenous rehydration (IVR) using the clinically relevant continuous outcome measure of duration of hospital admission. Methods/Design A prospective randomised multi-centre trial in Australia and New Zealand where children between 2 and 12 months of age with bronchiolitis, needing non oral fluid replacement, are randomised to receive either intravenous (IV) or nasogastric (NG) rehydration. 750 patients admitted to participating hospitals will be recruited, and will be followed daily during the admission and by telephone 1 week after discharge. Patients with chronic respiratory, cardiac, or neurological disease; choanal atresia; needing IV fluid resuscitation; needing an IV for other reasons, and those requiring CPAP or ventilation are excluded. The primary endpoint is duration of hospital admission. Secondary outcomes are complications, need for ICU admission, parental satisfaction, and an economic evaluation. Results will be analysed using t-test for continuous data, and chi squared for categorical data. Non parametric data will be log transformed. Discussion This trial will define the role of NGR and IVR in bronchiolitis Trail registration The trial is registered with the Australian and New Zealand Clinical Trials Registry - ACTRN12605000033640 PMID:20515467

  12. Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Power, Sarah, E-mail: sarahpower28@yahoo.co.uk; Kavanagh, Liam N.; Shields, Mary C.

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period.more » Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.« less

  13. The reversibility of reduced cortical vein compliance in normal-pressure hydrocephalus following shunt insertion.

    PubMed

    Bateman, G A

    2003-02-01

    Superficial cortical venous compression secondary to alterations in craniospinal compliance is implicated in the pathogenesis of normal pressure hydrocephalus (NPH). A reduction in the pulsation in the outflow of the cortical veins would be expected to occur following compression of these veins and this has been shown in NPH. If cortical vein compression is a causative factor in NPH, it would be expected that cortical vein compliance as measured by pulsatility would be significantly altered by a curative procedure i.e. shunt tube insertion. My purpose is to compare the blood flow pulsatility characteristics in a group of patients with NPH before and after shunt tube insertion. I initially studied 18 subjects without pathology with MRI flow quantification studies of the cerebral arteries and veins to define the range of normality. The main study involved 18 patients with idiopathic dementia and mild leukoaraiosis who served as controls and seven patients with NPH studied before and after shunt insertion. Arterial, superior sagittal and straight sinus pulsatility was not significantly different between the patients with idiopathic dementia and those NPH patients before or after shunting. Cortical vein pulsatility before shunting in the patients with NPH was 43% lower than in those with idiopathic dementia ( P=0.006). Following shunting, cortical vein pulsatility increased by 186% ( P=0.007). There is thus reduced compliance in cortical veins in NPH which is significantly increased in patients who respond to insertion of a shunt tube. These findings suggest that reversible elevation in cortical vein pressure and reversal of the normal absorption pathway for cerebrospinal fluid may be behind the pathophysiology of NPH.

  14. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding

    PubMed Central

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-01-01

    AIM: To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. METHODS: Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. RESULTS: In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. CONCLUSION: The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding. PMID:25009396

  15. Small-bore chest tubes seem to perform better than larger tubes in treatment of spontaneous pneumothorax.

    PubMed

    Iepsen, Ulrik Winning; Ringbæk, Thomas

    2013-06-01

    The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT).  This was a retrospective study of 104 cases (94 patients) of non-traumatic PT treated with chest tubes - either by pulmonary physicians (daytime and weekdays) using small-bore chest tubes, or by orthopaedic surgeons (remaining time slots) using large-bore chest tubes.  A total of 62 had primary spontaneous PT, 30 had secondary spontaneous PT and 12 had iatrogenic PT. A total of 62 patients were treated with large-bore (20-28 Fr) chest tubes placed with traditional thoracotomy, 42 patients were treated by a pulmonary physician, and in 30 of these cases a True-Close thoracic vent (11-13 Fr) was inserted. Patients treated with surgical chest tubes were comparable with patients treated with smaller chest tubes in terms of demographic data and type and size of PT. Compared with patients treated with smaller chest tubes, patients with surgical large-bore tubes had more complications (27.4% versus 9.5%; p = 0.026), a lower success rate (56.5% versus 85.7%; p = 0.002), and longer duration of chest tube (8.3 versus 4.9 days; p = 0.001) and of hospitalisation (11.8 versus 6.9 days; p = 0.004).  We found small chest tubes to be superior to large-bore chest tubes with regard to short-term outcomes in the treatment of non-traumatic PT.  not relevant. The project was approved by the Danish Data Protection Agency, file no. 2012-41-0554. 

  16. What is the yield of routine chest radiography following tube thoracostomy for trauma?

    PubMed

    Kong, Victor Y; Oosthuizen, George V; Clarke, Damian L

    2015-01-01

    Routine chest radiography (CXR) following tube thoracostomy (TT) is a standard practice in most trauma centres worldwide. Evidence supporting this routine practice is lacking and the actual yield is unknown. We performed a retrospective review of 1042 patients over a 4-year period who had a routine post-insertion CXR performed in accordance with current ATLS® recommendations. A total 1042 TTs were performed on 1004 patients. Ninety-one per cent of patients (913/1004) were males, and the median age for all patients was 24 years. Seventy-five per cent of all injuries (756/1004) were from penetrating trauma, and the remaining 25% (248/1004) were from blunt. The initial pathologies requiring TT were: haemopneumothorax: 34% (339/1042), haemothroax: 31% (314/1042), simple pneumothorax: 25% (256/1042), tension pneumothorax: 8% (77/1042) and open pneumothorax: 5% (54/1042). One hundred and three patients had TTs performed on clinical grounds alone without a pre-insertion CXR [Group A]. One hundred and ninety-one patients had a pre-insertion CXR but had persistent clinical concerns following insertion [Group B]. Seven hundred and ten patients had pre-insertion CXR but no clinical concerns following insertion [Group C]. Overall, 15% (152/1004) [9 from Group A, 111 from Group B and 32 from Group C] of all patients had their clinical management influenced as a direct result of the post-insertion CXR. Despite the widely accepted practice of routine CXR following tube thoracostomy, the yield is relatively low. In many cases, good clinical examination post tube insertion will provide warnings as to whether problems are likely to result. However, in the more rural setting, and in resource challenged environments, there is a relatively high yield from the CXR, which alters management. Further prospective studies are needed to establish or refute the role of the existing ATLS® guidelines in these specific environments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Cotton transformation via pollen tube pathway.

    PubMed

    Wang, Min; Zhang, Baohong; Wang, Qinglian

    2013-01-01

    Although many gene transfer methods have been employed for successfully obtaining transgenic cotton, the major constraint in cotton improvement is the limitation of genotype because the majority of transgenic methods require plant regeneration from a single transformed cell which is limited by cotton tissue culture. Comparing with other plant species, it is difficult to induce plant regeneration from cotton; currently, only a limited number of cotton cultivars can be cultured for obtaining regenerated plants. Thus, development of a simple and genotype-independent genetic transformation method is particularly important for cotton community. In this chapter, we present a simple, cost-efficient, and genotype-independent cotton transformation method-pollen tube pathway-mediated transformation. This method uses pollen tube pathway to deliver transgene into cotton embryo sacs and then insert foreign genes into cotton genome. There are three major steps for pollen tube pathway-mediated genetic transformation, which include injection of -foreign genes into pollen tube, integration of foreign genes into plant genome, and selection of transgenic plants.

  18. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    NASA Astrophysics Data System (ADS)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2018-04-01

    conductive sub-layer δ CSL and the nondimensional thickness of the conductive sub-layer y + CSL on the circular tubes with various twisted-tape inserts were determined on the basis of numerical solutions for the swirl velocities u sw ranging from 5.23 to 21.18 m/s. Correlations between the conductive sub-layer thickness δ CSL and the nondimensional thickness of the conductive sub-layer y + CSL for twisted-tape-induced swirl-flow heat transfer in a vertical circular tube were derived.

  19. Flexible deep brain neural probes based on a parylene tube structure

    NASA Astrophysics Data System (ADS)

    Zhao, Zhiguo; Kim, Eric; Luo, Hao; Zhang, Jinsheng; Xu, Yong

    2018-01-01

    Most microfabricated neural probes have limited shank length, which prevents them from reaching many deep brain structures. This paper reports deep brain neural probes with ultra-long penetrating shanks based on a simple but novel parylene tube structure. The mechanical strength of the parylene tube shank is temporarily enhanced during implantation by inserting a metal wire. The metal wire can be removed after implantation, making the implanted probe very flexible and thus minimizing the stress caused by micromotions of brain tissues. Optogenetic stimulation and chemical delivery capabilities can be potentially integrated by taking advantage of the tube structure. Single-shank prototypes with a shank length of 18.2 mm have been developed. The microfabrication process comprises of deep reactive ion etching (DRIE) of silicon, parylene conformal coating/refilling, and XeF2 isotropic silicon etching. In addition to bench-top insertion characterization, the functionality of developed probes has been preliminarily demonstrated by implanting into the amygdala of a rat and recording neural signals.

  20. The effect of cold application on pain due to chest tube removal.

    PubMed

    Ertuğ, Nurcan; Ulker, Saadet

    2012-03-01

    The aim of the research is to determine the effect of cold application on the pain owing to chest tube removal for patients with single pleural chest tube. Removal of chest tubes causes patients to feel pain and interventions used for reducing the pain owing to the removal of chest tubes are not sufficient. Controlled clinical trial with repeated measures. This study was conducted with 140 patients, of whom 70 patients were in the experimental group and 70 patients were in the control group, in a thoracic hospital in Turkey. Data were collected using a data collection form consisting of patients' demographic and health history and Visual Analogue Scale. Cold was applied to patients in the experimental group prior to chest tube removal. In the experimental group, skin temperature and pain intensity was measured for each patient at four time points. In the control group, pain intensity was evaluated for each patient at three time points. Data were evaluated using Chi-square and Repeated Measurements two-way anova tests. The Visual Analogue Scale score was measured immediately after the chest tube removal in the experimental group was 3·85, compared with 5·60 in the control group. There were significant differences on pain with cold application between the two groups prior and after the intervention. Age, gender, the number of days the chest tube was inserted and the chest tube insertion indication had no effect on the pain owing to chest tube removal. Cold application is effective in reducing the pain owing to chest tube removal. Cold application was recommended prior to chest tube removal to reduce the pain owing to removal of chest tube. © 2011 Blackwell Publishing Ltd.

  1. Generation of patterned cell co-cultures in silicone tubing using a microelectrode technique and electrostatic assembly.

    PubMed

    Kaji, Hirokazu; Sekine, Soichiro; Hashimoto, Masahiko; Kawashima, Takeaki; Nishizawa, Matsuhiko

    2007-01-01

    We report a method for producing patterned cell adhesion inside silicone tubing. A platinum needle microelectrode was inserted through the wall of the tubing and an oxidizing agent electrochemically generated at the inserted electrode. This agent caused local detachment of the anti-biofouling heparin layer from the inner surface of the tubing. The cell-adhesive protein fibronectin selectively adsorbed onto the newly exposed surface, making it possible to initiate a localized cell culture. The electrode could be readily set in place without breaking the tubular structure and, importantly, almost no culture solution leaked from the electrode insertion site after the electrode was removed. Ionic adsorption of poly-L-lysine at the tubular region retaining a heparin coating was used to switch the heparin surface from cell-repellent to cell-adhesive, thereby facilitating the adhesion of a second cell type. The combination of the electrode-based technique with electrostatic deposition enabled the formation of patterned co-cultures within the semi-closed tubular structure. The controlled co-cultures inside the elastic tubing should be of value for cell-cell interaction studies following application of chemical or mechanical stimuli and for tissue engineering-based bioreactors.

  2. Spectral analysis of hearing protector impulsive insertion loss.

    PubMed

    Fackler, Cameron J; Berger, Elliott H; Murphy, William J; Stergar, Michael E

    2017-01-01

    To characterise the performance of hearing protection devices (HPDs) in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. HPDs were measured per the impulsive test methods of ANSI/ASA S12.42- 2010 . Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analysed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Tested HPDs included a foam earplug, a level-dependent earplug and an electronic sound-restoration earmuff. IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Measurements of IPIL depend strongly on the source used to measure them, especially for HPDs with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD's performance.

  3. High aspect ratio catalytic reactor and catalyst inserts therefor

    DOEpatents

    Lin, Jiefeng; Kelly, Sean M.

    2018-04-10

    The present invention relates to high efficient tubular catalytic steam reforming reactor configured from about 0.2 inch to about 2 inch inside diameter high temperature metal alloy tube or pipe and loaded with a plurality of rolled catalyst inserts comprising metallic monoliths. The catalyst insert substrate is formed from a single metal foil without a central supporting structure in the form of a spiral monolith. The single metal foil is treated to have 3-dimensional surface features that provide mechanical support and establish open gas channels between each of the rolled layers. This unique geometry accelerates gas mixing and heat transfer and provides a high catalytic active surface area. The small diameter, high aspect ratio tubular catalytic steam reforming reactors loaded with rolled catalyst inserts can be arranged in a multi-pass non-vertical parallel configuration thermally coupled with a heat source to carry out steam reforming of hydrocarbon-containing feeds. The rolled catalyst inserts are self-supported on the reactor wall and enable efficient heat transfer from the reactor wall to the reactor interior, and lower pressure drop than known particulate catalysts. The heat source can be oxygen transport membrane reactors.

  4. Feasibility of an endotracheal tube-mounted camera for percutaneous dilatational tracheostomy.

    PubMed

    Grensemann, J; Eichler, L; Hopf, S; Jarczak, D; Simon, M; Kluge, S

    2017-07-01

    Percutaneous dilatational tracheostomy (PDT) in critically ill patients is often led by optical guidance with a bronchoscope. This is not without its disadvantages. Therefore, we aimed to study the feasibility of a recently introduced endotracheal tube-mounted camera (VivaSight™-SL, ET View, Misgav, Israel) in the guidance of PDT. We studied 10 critically ill patients who received PDT with a VivaSight-SL tube that was inserted prior to tracheostomy for optical guidance. Visualization of the tracheal structures (i.e., identification and monitoring of the thyroid, cricoid, and tracheal cartilage and the posterior wall) and the quality of ventilation (before puncture and during the tracheostomy) were rated on four-point Likert scales. Respiratory variables were recorded, and blood gases were sampled before the interventions, before the puncture and before the insertion of the tracheal cannula. Visualization of the tracheal landmarks was rated as 'very good' or 'good' in all but one case. Monitoring during the puncture and dilatation was also rated as 'very good' or 'good' in all but one. In the cases that were rated 'difficult', the visualization and monitoring of the posterior wall of the trachea were the main concerns. No changes in the respiratory variables or blood gases occurred between the puncture and the insertion of the tracheal cannula. Percutaneous dilatational tracheostomy with optical guidance from a tube-mounted camera is feasible. Further studies comparing the camera tube with bronchoscopy as the standard approach should be performed. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. Urethral catheter insertion forces: a comparison of experience and training.

    PubMed

    Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj

    2009-01-01

    This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  6. Heat Transfer Enhancement of Laminar Nanofluids Flow in a Circular Tube Fitted with Parabolic-Cut Twisted Tape Inserts

    PubMed Central

    Salman, Sami D.; Kadhum, Abdul Amir H.; Takriff, Mohd S.; Mohamad, Abu Bakar

    2014-01-01

    Numerical investigation has been carried out on heat transfer and friction factor characteristics of copper-water nanofluid flow in a constant heat-fluxed tube with the existence of new configuration of vortex generator using Computational Fluid Dynamics (CFD) simulation. Two types of swirl flow generator: Classical twisted tape (CTT) and Parabolic-cut twisted tape (PCT) with a different twist ratio (y = 2.93, 3.91 and 4.89) and different cut depth (w = 0.5, 1.0 and 1.5 cm) with 2% and 4% volume concentration of CuO nanofluid were used for simulation. The effect of different parameters such as flow Reynolds number, twist ratio, cut depth and nanofluid were considered. The results show that the enhancement of heat transfer rate and the friction factor induced by the Classical (CTT) and Parabolic-cut (PCT) inserts increases with twist ratio and cut depth decreases. The results also revealed that the heat transfer enhancement increases with an increase in the volume fraction of the CuO nanoparticle. Furthermore, the twisted tape with twist ratio (y = 2.93) and cut depth w = 0.5 cm offered 10% enhancement of the average Nusselt number with significant increases in friction factor than those of Classical twisted tape. PMID:24605055

  7. Spectral analysis of hearing protector impulsive insertion loss

    PubMed Central

    Fackler, Cameron J.; Berger, Elliott H.; Murphy, William J.; Stergar, Michael E.

    2017-01-01

    Objective To characterize the performance of hearing protection devices in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. Design Hearing protectors were measured per the impulsive test methods of ANSI/ASA S12.42-2010. Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analyzed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Study Sample Tested devices included a foam earplug, a level-dependent earplug, and an electronic sound-restoration earmuff. Results IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Conclusions Measurements of IPIL depend strongly on the source used to measure them, especially for hearing protectors with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD’s performance. PMID:27885881

  8. Medication administration through enteral feeding tubes.

    PubMed

    Williams, Nancy Toedter

    2008-12-15

    An overview of enteral feeding tubes, drug administration techniques, considerations for dosage form selection, common drug interactions with enteral formulas, and methods to minimize tube occlusion is given. Enteral nutrition through a feeding tube is the preferred method of nutrition support in patients who have a functioning gastrointestinal tract but who are unable to be fed orally. This method of delivering nutrition is also commonly used for administering medications when patients cannot swallow safely. However, several issues must be considered with concurrent administration of oral medications and enteral formulas. Incorrect administration methods may result in clogged feeding tubes, decreased drug efficacy, increased adverse effects, or drug-formula incompatibilities. Various enteral feeding tubes are available and are typically classified by site of insertion and location of the distal tip of the feeding tube. Liquid medications, particularly elixirs and suspensions, are preferred for enteral administration; however, these formulations may be hypertonic or contain large amounts of sorbitol, and these properties increase the potential for adverse effects. Before solid dosage forms are administered through the feeding tube, it should be determined if the medications are suitable for manipulation, such as crushing a tablet or opening a capsule. Medications should not be added directly to the enteral formula, and feeding tubes should be properly flushed with water before and after each medication is administered. To minimize drug-nutrient interactions, special considerations should be taken when administering phenytoin, carbamazepine, warfarin, fluoroquinolones, and proton pump inhibitors via feeding tubes. Precautions should be implemented to prevent tube occlusions, and immediate intervention is required when blockages occur. Successful drug delivery through enteral feeding tubes requires consideration of the tube size and placement as well as careful

  9. Experience in Bedside Placement, Clinical Validity, and Cost-Efficacy of a Self-Propelled Nasojejunal Feeding Tube

    PubMed Central

    Puiggròs, Carolina; Molinos, Rosa; Ortiz, M. Dolors; Ribas, Montserrat; Romero, Carlos; Vázquez, Concepcion; Segurola, Hegoi; Burgos, Rosa

    2015-01-01

    Background: The procedures needed to insert nasojejunal tubes (NJTs) are often invasive or uncomfortable for the patient and require hospital resources. The objectives of this study were to describe our experience in inserting a self-propelling NJT with distal pigtail end and evaluate clinical validity and cost efficacy of this enteral nutrition (EN) approach compared with parenteral nutrition (PN). Materials and Methods: Prospective study from July 2009 to December 2010, including hospitalized noncritical patients who required short-term jejunal EN. The tubes were inserted at bedside, using intravenous erythromycin as a prokinetic drug. Positioning was considered correct when the distal end was beyond the ligament of Treitz. Migration failure was considered when the tube was not positioned into the jejunum within 48 hours postinsertion. Results: Fifty-six insertions were recorded in 47 patients, most frequently in severe acute pancreatitis (69.6%). The migration rates at 18 and 48 hours postinsertion were 73.2% and 82.1%, respectively. There was migration failure in 8.9% of cases, and 8.9% were classified null (the tube was no longer in the gastrointestinal tract at 18 hours). There were no reported or observed complications. The mean duration of the EN was 12 ± 10.8 days. Five different types of EN formula were used. The total study cost was 53.9% lower compared with using PN in all patients. Conclusions: Our study demonstrated that bedside insertion of a self-propelling NJT is a safe, cost-effective, and successful technique for postpyloric enteral feeding in at least 73% of the patients, and only 18% of patients could eventually need other placement techniques. It can avoid the need for more aggressive or expensive placement techniques or even PN if we cannot achieve enteral access. PMID:26214512

  10. The Fate of Fat: Pre-Exposure Fat Losses during Nasogastric Tube Feeding in Preterm Newborns

    PubMed Central

    Rayyan, Maissa; Rommel, Nathalie; Allegaert, Karel

    2015-01-01

    Deficient nutritional support and subsequent postnatal growth failure are major covariates of short- and long-term outcome in preterm neonates. Despite its relevance, extrauterine growth restriction (EUGR) is still prevalent, occurring in an important portion of extremely preterm infants. Lipids provide infants with most of their energy needs, but also cover specific supplies critical to growth, development and health. The use of human milk in preterm neonates results in practices, such as milk storage, pasteurization and administration by an infusion system. All of these pre-exposure manipulations significantly affect the final extent of lipid deposition in the intestinal track available for absorption, but the impact of tube feeding is the most significant. Strategies to shift earlier to oral feeding are available, while adaptations of the infusion systems (inversion, variable flow) have only more recently been shown to be effective in “in vitro”, but not yet in “in vivo” settings. Pre-exposure-related issues for drugs and nutritional compounds show similarities. Therefore, we suggest that the available practices for “in vitro” drug evaluations should also be considered in feeding strategies to further reduce pre-exposure losses as a strategy to improve the nutritional status and outcome of preterm neonates. PMID:26230707

  11. Feeding tubes and health costs postinsertion in nursing home residents with advanced dementia.

    PubMed

    Hwang, Deborah; Teno, Joan M; Gozalo, Pedro; Mitchell, Susan

    2014-06-01

    The best evidence suggests that feeding tubes are ineffective in persons with advanced dementia. Little is known about their health care costs. To estimate Medicare costs attributable to inpatient care among nursing home (NH) residents with advanced dementia during the year following the placement of a percutaneous endoscopic gastrostomy (PEG) tube during an index hospitalization. Medicare claims (1999-2009) and Minimum Data Set data (1999-2009) were used to estimate Medicare costs attributable to inpatient care among NH residents with advanced dementia during the year following the placement of a PEG tube and compared with those who did not get a PEG tube. The study used a 3:1 propensity-matched cohort design. Matched residents with (n=1924, 68.9% female, 28.8% African American, average age 83.1 years) and without (weighted n=1924, unique n=4337) PEG insertion showed comparable sociodemographic characteristics, similar rates of feeding tube risk factors, and similar mortality (51.9% 180 day mortality among those with a feeding tube vs. 49.8% among those without a feeding tube, P=0.11). One year hospital costs were $2224 higher in NH residents with a feeding tube ($10,191 vs. $7967, 95% CI of difference=$1514, $2933), with those with a feeding tube likely to spend more time in an intensive care unit (1.92 vs. 1.29 days, 95% CI of difference=0.34, 0.92 days). In an analysis controlling for selection bias, PEG tube insertion is associated with a small but significant increase in annual inpatient health care costs, as well as in hospital and intensive care unit days, postinsertion. Copyright © 2014 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.

  12. Nasogastric feeding at the end of life: a virtue ethics approach.

    PubMed

    Krishna, Lalit

    2011-07-01

    The use of Nasogastric (NG) feeding in the provision of artificial nutrition and hydration at the end of life has, for the most part, been regarded as futile by the medical community. This position has been led chiefly by prevailing medical data. In Singapore, however, there has been an increase in its utilization supported primarily by social, religious and cultural factors expressly to prolong life of the terminally ill patient. Here this article will seek to review the ethical and clinical impact of this treatment and provide some understanding for such decisions in the light of the Duty of Palliative Care [DoPC]. Complemented by virtue ethics theory, the DoPC highlights and seeks to realize the individual case specific goals of care that maximize comfort and quality of life of the patient in the face of rapid attenuation of treatment options and the eminence of the final outcome by considering each of these factors individually in order to provide the best outcome for the patient and the family.

  13. Techniques for the insertion of the ProSeal laryngeal mask airway: comparison of the Foley airway stylet tool with the introducer tool in a prospective, randomized study.

    PubMed

    Chen, Mao-Kai; Hsu, Hung-Te; Lu, I-Cheng; Shih, Chih-Kai; Shen, Ya-Chun; Tseng, Kuang-Yi; Cheng, Kuang-I

    2014-01-01

    Many tools have been developed to facilitate the insertion of the ProSeal laryngeal mask airway (LMA) insertion, which can be impeded by folding of its soft cuff. The aim of this study was to compare the efficiency of ProSeal LMA insertion guided by a soft, direct optical Foley Airway Stylet Tool (FAST) with the standard introducer tool (IT). One hundred sixty patients undergoing general anesthesia using the ProSeal LMA as an airway management device were randomly allocated to either FAST-guided or IT-assisted groups. Following ProSeal LMA insertion, the glottic and esophageal openings were identified using a fiberoptic bronchoscope introduced through the airway and the drain tube. The primary outcomes were time taken to insert the ProSeal LMA and the success rate at the first attempt. Secondary end points included ease of insertion, hemodynamic response to insertion, and postoperative adverse events recorded in the recovery room and on the first postoperative morning. One hundred forty patients were included in the final analysis: 66 in the FAST-guided group and 74 in the IT-assisted group. The success rate of FAST device-guided ProSeal LMA insertion (95.7%) was broadly comparable with IT-assisted insertion (98.7%). However, the time taken to insert the ProSeal LMA was significantly longer when the FAST technique was used (p <0.001). The incidence of correct alignment of the airway tube and the drain tube did not differ significantly between the groups. There were no significant differences in ease of insertion or hemodynamic responses to insertion, except that the incidence of postoperative sore throat was significantly higher in the FAST group on the first postoperative day (22.2% compared with 6.8% in the IT group; p = 0.035). Both FAST-guided and IT-assisted techniques achieved correct ProSeal LMA positioning, but the IT technique was significantly quicker and less likely to cause a sore throat. ClinicalTrials.gov Identifier: NCT02048657.

  14. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

    PubMed Central

    2018-01-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. PMID:29372629

  15. Analysis of the light-water flooding of the HFBR thimble tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carew, J.F.; Aronson, A.L.; Cokinos, D.M.

    The fuel elements surrounding the central vertical thimble tubes in the Brookhaven National Laboratory High-Flux Beam Reactor (HFBR) are highly undermoderated, and light-water flooding of these irradiation thimbles results in a positive core reactivity insertion. The light-water contamination of the D{sub 2}O thimble tube coolant is the result of a postulated double-ended guillotine break of a U tube in the experimental facilities heat exchanger during the HFBR light-water flooding (LWF) event. While this event has a low probability (1.3 x 10{sup {minus}4}/yr), the HFBR protection system must ensure adequate thermal margin during the power transient. This paper summarizes the analysismore » of the HFBR thimble-tube LWF event.« less

  16. Reliable experimental setup to test the pressure modulation of Baerveldt Implant tubes for reducing post-operative hypotony

    NASA Astrophysics Data System (ADS)

    Ramani, Ajay

    Glaucoma encompasses a group of conditions that result in damage to the optic nerve and can cause loss of vision and blindness. The nerve is damaged due to an increase in the eye's internal (intraocular) pressure (IOP) above the nominal range of 15 -- 20 mm Hg. There are many treatments available for this group of diseases depending on the complexity and stage of nerve degradation. In extreme cases where drugs or laser surgery do not create better conditions for the patient, ophthalmologists use glaucoma drainage devices to help alleviate the IOP. Many drainage implants have been developed over the years and are in use; but two popular implants are the Baerveldt Glaucoma Implant and the Ahmed Glaucoma Valve Implant. Baerveldt Implants are non-valved and provide low initial resistance to outflow of fluid, resulting in post-operative complications such as hypotony, where the IOP drops below 5 mm of Hg. Ahmed Glaucoma Valve Implants are valved implants which initially restrict the amount of fluid flowing out of the eye. The long term success rates of Baerveldt Implants surpass those of Ahmed Valve Implants because of post-surgical issues; but Baerveldt Implants' initial effectiveness is poor without proper flow restriction. This drives the need to develop new ways to improve the initial effectiveness of Baerveldt Implants. A possible solution proposed by our research team is to place an insert in the Baerveldt Implant tube of inner diameter 305 microns. The insert must be designed to provide flow resistance for the early time frame [e.g., first 30 -- 60 post-operative days] until sufficient scar tissue has formed on the implant. After that initial stage with the insert, the scar tissue will provide the necessary flow resistance to maintain the IOP above 5 mm Hg. The main objective of this project was to develop and validate an experimental apparatus to measure pressure drop across a Baerveldt Implant tube, with and without inserts. This setup will be used in the

  17. Pre-radiotherapy feeding tube identifies a poor prognostic subset of postoperative p16 positive oropharyngeal carcinoma patients.

    PubMed

    Verma, Vivek; Liu, Jingxia; Eschen, Laura; Danieley, Jonathan; Spencer, Christopher; Lewis, James S; Diaz, Jason; Piccirillo, Jay F; Adkins, Douglas R; Nussenbaum, Brian; Thorstad, Wade L; Gay, Hiram A

    2015-01-09

    This study explores variables associated with poor prognosis in postoperative p16 positive oropharyngeal squamous cell carcinoma (OPSCC) patients undergoing adjuvant radiotherapy or chemoradiotherapy. Specifically, analysis was done related to timing of feeding tube insertion relative to radiotherapy. From 1997-2009, of 376 consecutive patients with OPSCC, 220 received adjuvant IMRT, and 97 were p16 positive and eligible. Of these, 23 had feeding tube placement before IMRT (B-FT), 32 during/after IMRT (DA-FT), and 42 had no feeding tube (NO-FT). Feeding tubes were not placed prophylactically. These three groups were analyzed for differential tumor, patient, treatment, and feeding tube characteristics, as well as differences in overall survival (OS), disease free survival (DFS), and distant metastasis free survival (DMFS). Pre-RT FT insertion was associated with higher tumor size and depth, T (but not N) and overall stage, comorbidities, presence of chemotherapy, and less use of transoral laser microsurgery/transoral bovie. Additionally, time from surgery to IMRT completion was also statistically longer in the B-FT group. The feeding tube was permanent in 52% of patients in the B-FT group versus 16% in the DA-FT group (p = 0.0075). The 5-year OS for the NO-FT, DA-FT, and B-FT groups was 90%, 86%, and 50%, respectively. The 5-year DFS for the NO-FT, DA-FT, and B-FT groups was 87.6%, 83.6%, and 42.7%, respectively. Multivariate analysis showed that for OS and DFS, feeding tube placement timing and smoking history were statistically significant. Due to the poor prognosis of early FT insertion, the presence of FTs at time of radiotherapy consultation can be used as an alternate marker to identify a subset of p16 positive OPSCC patients that have a poor prognosis.

  18. Cold cathode vacuum discharge tube

    DOEpatents

    Boettcher, Gordon E.

    1998-01-01

    A cold cathode vacuum discharge tube, and method for making same, with an interior surface of the trigger probe coated with carbon deposited by carbon vapor deposition (CVD) or diamond-like carbon (DLC) deposition. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging.

  19. Nutrition accesses among patients receiving enteral treatment in the home environment.

    PubMed

    Sznajder, Janusz; Ślefarska-Wasilewska, Marta; Wójcik, Piotr

    2017-10-31

    Enteral feeding in the home environment is connected with creating access to digestive tract, and thanks to that, this kind of treatment is possible. The gold standard in enteral nutrition is PEG, other types of access are: nasogastric tube, gastronomy and jejunostomy. In the article 851 patients who were treated nutritionally in the home environment, in the nutrition clinic, Nutrimed Górny Śląsk, were analyzed. It was described how, in practice, the schedule of nutrition access looks like in the nutrition clinic at a time of qualifying patients to the treatment (PEG 47,35%, gastronomy 18,91%, nasogastric tube 17,39%,jejunostomy 16,33%) and how it changes among patients treated in the nutrition clinic during specific period of time - to the treatment there were qualified patients with at least three-month period of therapy ( second evaluation: PEG 37,01%, gastrostomy 31,13%, nasogastric tube 16,98%, jejunostomy 15,86%). The structure of changes was described, also the routine and the place in what exchanging or changing nutrition access was analyzed. The biggest changes in quantity, among all groups of ill people concerned patients with PEG and gastronomy. In most cases the intervention connected with exchanging access to the digestive tract could be implemented at patient's home.

  20. Methods for batch fabrication of cold cathode vacuum switch tubes

    DOEpatents

    Walker, Charles A [Albuquerque, NM; Trowbridge, Frank R [Albuquerque, NM

    2011-05-10

    Methods are disclosed for batch fabrication of vacuum switch tubes that reduce manufacturing costs and improve tube to tube uniformity. The disclosed methods comprise creating a stacked assembly of layers containing a plurality of adjacently spaced switch tube sub-assemblies aligned and registered through common layers. The layers include trigger electrode layer, cathode layer including a metallic support/contact with graphite cathode inserts, trigger probe sub-assembly layer, ceramic (e.g. tube body) insulator layer, and metallic anode sub-assembly layer. Braze alloy layers are incorporated into the stacked assembly of layers, and can include active metal braze alloys or direct braze alloys, to eliminate costs associated with traditional metallization of the ceramic insulator layers. The entire stacked assembly is then heated to braze/join/bond the stack-up into a cohesive body, after which individual switch tubes are singulated by methods such as sawing. The inventive methods provide for simultaneously fabricating a plurality of devices as opposed to traditional methods that rely on skilled craftsman to essentially hand build individual devices.

  1. Nephrostomy tube-free versus nephrostomy tube for renal drainage after percutaneous nephrolithotomy: a systematic review and meta-analysis.

    PubMed

    Shen, Pengfei; Liu, Yong; Wang, Jia

    2012-01-01

    Historically, percutaneous nephrostomy drainage following percutaneous nephrolithotomy (PNL) has been considered the standard of care. More recently, however, an increasing number of centers are performing tubeless (with insertion of JJ ureteric stent) or totally tubeless (with no internal or external drainage) PNL with impressive outcome data. This systematic review is to compare the clinical therapeutic efficacy and safety of nephrostomy tube-free (NT-free) and standard PNL. We searched PubMed (1966 to April 2011), Embase (1966 to April 2011), and the Cochrane Library without language restriction. All randomized controlled trials that compared NT-free PNL (using a double-J stent) with standard PNL were enrolled in this review. The Cochrane Collaboration's RevMan5.0.2 software was used for statistical analysis. Nine studies involving 547 patients were included. Patients were divided into 4 groups: NT-free group, small tube group (8-9 Fr), middle tube group (16-18 Fr), and large tube group (20-24 Fr). Meta-analysis showed that: (1) with regard to hospital stay (h) and visual analog scale scores for postoperative pain on day 1, there was no significant difference between the NT-free group and the small tube group, but there were differences between the NT-free group versus the middle and large tube groups; (2) for puncture site urinary leakage, no significant difference was found between the NT-free group and the small and middle tube groups; (3) no significant difference was found with regard to transfusion, fever or infection, operative time between the NT-free group and the 3 tube groups. The clinical efficacy and safety of NT-free and small tube are similar in all measurements. Compared with the middle and large tubes, NT-free PNL could reduce hospital stay and postoperative analgesia requirement without increasing other complications. Copyright © 2012 S. Karger AG, Basel.

  2. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2010-12-14

    A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.

  3. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2007-01-02

    A clog-resistant injector spray nozzle allows relatively unobtrusive insertion through a small access aperture into existing ductwork in occupied buildings for atomized particulate sealing of a ductwork. The spray nozzle comprises an easily cleaned and easily replaced straight liquid tube whose liquid contents are principally propelled by a heated propellant gas, such as heated air. Heat transfer is minimized from the heated propellant gas to the liquid tube until they both exit the injector, thereby greatly reducing the likelihood of nozzle clogging. A method of duct sealing using particles driven by heated propellant gas is described, whereby duct-sealing operations become both faster, and commercially practicable in inhabited commercial and residential buildings.

  4. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    PubMed

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  5. Cold cathode vacuum discharge tube

    DOEpatents

    Boettcher, G.E.

    1998-03-10

    A cold cathode vacuum discharge tube, and method for making same, are disclosed with an interior surface of the trigger probe coated with carbon deposited by carbon vapor deposition (CVD) or diamond-like carbon (DLC) deposition. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging. 15 figs.

  6. Cold cathode vacuum discharge tube

    DOEpatents

    Boettcher, G.E.

    1998-04-14

    A cold cathode vacuum discharge tube, and method for making same, with an interior surface of the trigger probe coated with carbon deposited by chemical vapor deposition (CVD) or diamond-like carbon (DLC) deposition are disclosed. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging. 14 figs.

  7. Treatment of Snoring with a Nasopharyngeal Airway Tube

    PubMed Central

    Chang, Edward T.; Fernandez-Salvador, Camilo; Capasso, Robson

    2016-01-01

    Objective. To study the feasibility of a standard nasopharyngeal airway tube (NPAT) as treatment for snoring. Methods. An obese 35-year-old man, who is a chronic, heroic snorer, used NPATs while (1) the patient's bedpartner scored the snoring and (2) the patient recorded himself with the smartphone snoring app “Quit Snoring.” Baseline snoring was 8–10/10 (10 = snoring that could be heard through a closed door and interrupted the bedpartner's sleep to the point where they would sometimes have to sleep separately) and 60–200 snores/hr. Several standard NPATs were tested, consisting of soft polyvinyl chloride material raging between 24- and 36-French (Fr) tubes. Results. The 24 Fr tube did not abate snoring. The 26 Fr tube was able to abate the snoring sound most of the night (smartphone app: 11.4 snores/hr, bedpartner VAS = 2/10). The 28 and 30 Fr tubes abated the snoring sound the entire time worn (smartphone app: 0 snores, bedpartner VAS 0/10) but could not be tolerated more than 2.5 hours. The tube of 36 Fr size could not be inserted, despite several attempts bilaterally. Conclusion. Appropriately sized nasopharyngeal airway tubes may abate the snoring sound; however, as in this patient, they may be too painful and intolerable for daily use. PMID:27795710

  8. Occult pneumothorax in blunt trauma: is there a need for tube thoracostomy?

    PubMed

    Zhang, M; Teo, L T; Goh, M H; Leow, J; Go, K T S

    2016-12-01

    Occult pneumothorax (OPTX) is defined as air within the pleural cavity that is undetectable on normal chest X-rays, but identifiable on computed tomography. Currently, consensus is divided between tube thoracostomy and conservative management for OPTX. The aim of this retrospective study is to determine whether OPTX can be managed conservatively and whether any adverse events occur under conservative management. Data on all trauma patients from 1 Jan 2010 to 31 December 2012 were obtained from our hospital's trauma registry. All patients with occult pneumothorax who had chest X-ray (CXR) and any CT scan visualizing the thorax were included. The exclusion criteria included those with penetrating wounds; CXR showing pneumothorax, hemothorax, or hemopneumothorax; those with prophylactic chest tube insertion before CT; and those with no CT diagnosis of OPTX. The complications of these patients were analyzed to determine if tube thoracostomy is necessary for OPTX and whether not inserting it would alter the outcome significantly. A total of 1564 cases were reviewed and 83 patients were included. Of these 83 patients, 35 (42.2 %) had tube thoracostomy after OPTX detection and 48 (57.8 %) were observed initially. Patients who had tube thoracostomy had similar ISS compared to those without (median ISS 17 vs. 18.5, p = 0.436). Out of the 48 patients who did not have tube thoracostomy on detection of an OPTX, 4 (8.3 %) had complications. In the group of 35 patients who had tube thoracostomy on detection of an OPTX, 7 (20 %) had complications. Of the 83 patients, a total of 12 patients had IPPV, of which 7 (58.3 %) had tube thoracostomy and 5 (41.7 %) did not. Patients who had tube thoracostomy under our care have a statistically significant likelihood of experiencing any complication compared to those without tube thoracostomy (odds ratio 9.92. The median length of stay was also longer (13 days) in those who had tube thoracostomy compared to those without (5

  9. Economic evaluation of nasogastric versus intravenous hydration in infants with bronchiolitis.

    PubMed

    Oakley, Ed; Carter, Rob; Murphy, Bridie; Borland, Meredith; Neutze, Jocelyn; Acworth, Jason; Krieser, David; Dalziel, Stuart; Davidson, Andrew; Donath, Susan; Jachno, Kim; South, Mike; Babl, Franz E

    2017-06-01

    Bronchiolitis is the most common lower respiratory tract infection in infants and the leading cause of hospitalisation. We aimed to assess whether intravenous hydration (IVH) was more cost-effective than nasogastric hydration (NGH) as a planned secondary economic analysis of a randomised trial involving 759 infants (aged 2-12 months) admitted to hospital with a clinical diagnosis of bronchiolitis and requiring non-oral hydration. No Australian cost data exist to aid clinicians in decision-making around interventions in bronchiolitis. Cost data collections included hospital and intervention-specific costs. The economic analysis was reduced to a cost-minimisation study, focusing on intervention-specific costs of IVH versus NGH, as length of stay was equal between groups. All analyses are reported as intention to treat. Intervention costs were greater for IVH than NGH ($113 vs $74; cost difference of $39 per child). The intervention-specific cost advantage to NGH was robust to inter-site variation in unit prices and treatment activity. Intervention-specific costs account for <10% of total costs of bronchiolitis admissions, with NGH having a small cost saving across all sites. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  10. Pathogenesis and Treatment of Cerebral Air Embolism and Associated Disorders.

    DTIC Science & Technology

    1984-04-01

    blades) 12. 7.0, 8.0 and 9.0-mm endotracheal tubes 13. Endotracheal tube stylet 14. Esophageal obturator airway 15. Tracheal suction catheters (14F) 17 r...16. Nasogastric suction tube and Tumee syringe 17. Tincture of Benzoin 18. 2-in waterproof tape 19. Precordial stethoscope 20. Esophageal stethoscope...be justified. If an endotracheal tube cannot be passed, an esophageal obturator airway may be useful. If such an airway Is used, the newer models

  11. Decision-Making Quality in Parents Considering Adenotonsillectomy or Tympanostomy Tube Insertion for Their Children.

    PubMed

    Hong, Paul; Maguire, Erin; Purcell, Mary; Ritchie, Krista C; Chorney, Jill

    2017-03-01

    Shared decision making is a process in which clinicians and patients make health care decisions in a collaborative manner using the most up-to-date evidence, while considering patient values and preferences. Shared decision making is thought to have a positive influence on the decision-making process in medicine. To describe the level of decisional conflict and decisional regret experienced by parents considering surgery for their children and to determine relations among decisional conflict, decisional regret, and shared decision making. A prospective cohort study was conducted at an academic pediatric otolaryngology clinic. Participants included 126 parents of children younger than 6 years who underwent consultation for adenotonsillectomy or tympanostomy tube insertion. Parent participants completed the Shared Decision Making Questionnaire-Parent version, Decisional Conflict Scale (DCS), and Decisional Regret Scale (DRS). Surgeons completed the Shared Decision Making Questionnaire-Physician version. This study included 126 parents; 102 women (mean [SD] age, 33.2 [5.1] years) and 24 men (mean [SD] age, 35.6 [6.3] years). Overall, 34 parents (26%) reported clinically significant decisional conflict. Only 1 parent experienced moderate to strong decisional regret; 28 parents (43.7%) had mild decisional regret. Both parent and physician ratings of shared decision making were significantly negatively correlated with total DCS scores. Parent SDM-Q-9 and total DCS scores were significantly negatively correlated (rs[118] = -0.582; P < .001). Similarly, physician SDM-Q-Doc and total DCS scores were also significantly negatively correlated (rs[118] = -0.221; P = .04). Only parent ratings of shared decision making were significantly negatively correlated with total DRS scores (rs[63] = -0.254; P = .045). Those parents with clinically significant decisional conflict had significantly higher DRS scores (P = .02). Many parents experienced significant

  12. In vivo laser-based imaging of the human fallopian tube for future cancer detection

    NASA Astrophysics Data System (ADS)

    Seibel, Eric J.; Melville, C. David; Johnston, Richard S.; Gong, Yuanzheng; Agnew, Kathy; Chiang, Seine; Swisher, Elizabeth M.

    2015-03-01

    Inherited mutations in BRCA1 and BRCA2 lead to 20-50% lifetime risk of ovarian, tubal, or peritoneal carcinoma. Clinical recommendations for women with these genetic mutations include the prophylactic removal of ovaries and fallopian tubes by age 40 after child-bearing. Recent findings suggest that many presumed ovarian or peritoneal carcinomas arise in fallopian tube epithelium. Although survival rate is <90% when ovarian cancer is detected early (Stage_I), 70% of women have advanced disease (Stage_III/IV) at presentation when survival is less than 30%. Over the years, effective early detection of ovarian cancer has remained elusive, possibly because screening techniques have mistakenly focused on the ovary as origin of ovarian carcinoma. Unlike ovaries, the fallopian tubes are amenable to direct visual imaging without invasive surgery, using access through the cervix. To develop future screening protocols, we investigated using our 1.2- mm diameter, forward-viewing, scanning fiber endoscope (SFE) to image luminal surfaces of the fallopian tube before laparoscopic surgical removal. Three anesthetized human subjects participated in our protocol development which eventually led to 70-80% of the length of fallopian tubes being imaged in scanning reflectance, using red (632nm), green (532nm), and blue (442nm) laser light. A hysteroscope with saline uterine distention was used to locate the tubal ostia. To facilitate passage of the SFE through the interstitial portion of the fallopian tube, an introducer catheter was inserted 1- cm through each ostia. During insertion, saline was flushed to reduce friction and provide clearer viewing. This is likely the first high-resolution intraluminal visualization of fallopian tubes.

  13. Note: An improved solenoid driver valve for miniature shock tubes.

    PubMed

    Lynch, P T

    2016-05-01

    A solenoid driver valve has been built to improve the operating performance of diaphragmless shock tubes, which are used for high pressure, high temperature chemical kinetics, and fluid mechanics studies. For shock tube driver application, the most important characteristics are those of sealing, strength, and quality of the generated shock waves and repeatability of opening characteristics and therefore subsequent post-shock conditions. The main features of the new driver valve are a face o-ring sealing design of the valve, the large internal volume, and through inserts near the solenoid core: adjustable opening characteristics of the valve.

  14. Jejunal feeding tubes can be efficiently and independently placed by intensive care unit teams.

    PubMed

    Welpe, Pascal; Frutiger, Adrian; Vanek, Patrik; Kleger, Gian-Reto

    2010-01-01

    Nutrition support is an important therapeutic measure in critically ill patients. Several studies have shown that the enteral route is preferable to the parenteral route. Insertion of a feeding tube beyond the ligament of Treitz combined with continuous gastric drainage will reduce regurgitation and probably also the rate of nosocomial pneumonia. This study was conducted to assess the safety, success rate, and time required to establish jejunal nutrition by the fluoroscopy-guided technique in intensive care unit (ICU) patients. This was a prospective observational study in the ICUs of a 300-bed and a 600-bed community hospital. Indications were large gastric residuals during attempted gastric feeding, severe acute pancreatitis, or recurrent aspiration. Feeding tubes were introduced by the ICU staff at bedside under fluoroscopic guidance (a senior ICU physician and a resident or a registered ICU nurse). The correct jejunal position was documented by the application of a radiopaque contrast medium through the tube. After confirmation of the correct position, jejunal tube feeding was immediately started. The insertion procedure in 38 patients lasted a median of 17 minutes. The median time from decision to place the tube until start of enteral feeding was 141 minutes. The success rate was 84.2%. No adverse events were observed. Fluoroscopic placement of a jejunal feeding tube at the bedside is fast, is safe, and has a high success rate when performed by well-trained ICU staff. Using this method makes the ICU team more self-sufficient when critically ill patients require enteral nutrition and no gastroenterologist is available.

  15. Replacement of Mushroom Cage Gastrostomy Tube Using a Modified Technique to Allow Percutaneous Replacement with an Endoscopic Tube in Patients with Amyotrophic Lateral Sclerosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ammar, Thoraya; Rio, Alan; Ampong, Mary Ann

    2010-06-15

    Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, withmore » modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.« less

  16. Measurement of Work Generation and Improvement in Performance of a Pulse Tube Engine

    NASA Astrophysics Data System (ADS)

    Hamaguchi, Kazuhiro; Futagi, Hiroaki; Yazaki, Taichi; Hiratsuka, Yoshikatsu

    Apart from double acting type engines, Stirling engines have either 2 pistons in 2 cylinders or 2 pistons in a single cylinder. Typically, the heater, regenerator and cooler are installed between the 2 pistons. The pulse tube engine, on the other hand, consists of a single piston in a single cylinder, a pulse tube, a heater, a regenerator, a cooler and a second cooler. For this paper, a simple prototype engine that uses air at normal atmospheric pressure as the working gas was fabricated. The oscillating velocity of the working gas in the pulse tube was measured using LDV, and the work flow emitting out of the pulse tube was observed. In addition, the effect of inserting heat storage material in the pulse tube on shaft power and indicated power was examined experimentally. A dramatic increase in the shaft power was achieved.

  17. Estimation of optimal nasotracheal tube depth in adult patients.

    PubMed

    Ji, Sung-Mi

    2017-12-01

    The aim of this study was to estimate the optimal depth of nasotracheal tube placement. We enrolled 110 patients scheduled to undergo oral and maxillofacial surgery, requiring nasotracheal intubation. After intubation, the depth of tube insertion was measured. The neck circumference and distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch were measured. To estimate optimal tube depth, correlation and regression analyses were performed using clinical and anthropometric parameters. The mean tube depth was 28.9 ± 1.3 cm in men (n = 62), and 26.6 ± 1.5 cm in women (n = 48). Tube depth significantly correlated with height (r = 0.735, P < 0.001). Distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch correlated with depth of the endotracheal tube (r = 0.363, r = 0.362, and r = 0.546, P < 0.05). The tube depth also correlated with the sum of these distances (r = 0.646, P < 0.001). We devised the following formula for estimating tube depth: 19.856 + 0.267 × sum of the three distances (R 2 = 0.432, P < 0.001). The optimal tube depth for nasotracheally intubated adult patients correlated with height and sum of the distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch. The proposed equation would be a useful guide to determine optimal nasotracheal tube placement.

  18. Effect of saline 0.9% or Plasma-Lyte 148 therapy on feeding intolerance in patients receiving nasogastric enteral nutrition.

    PubMed

    Reddy, Sumeet; Bailey, Michael; Beasley, Richard; Bellomo, Rinaldo; Mackle, Diane; Psirides, Alex; Young, Paul

    2016-09-01

    To compare the effect of Plasma-Lyte (PL)-148 and saline 0.9% (saline) on gastrointestinal (GI) feeding intolerance in mechanically ventilated patients receiving nasogastric (NG) feeding in an intensive care unit. A single-centre pilot study, nested within a multicentre, double-blind, cluster-randomised, double-crossover trial, performed in a mixed medical and surgical ICU. All adult patients who required crystalloid fluid therapy as part of the 0.9% Saline versus Plasma-Lyte 148 for Intensive Care Unit Fluid Therapy (SPLIT) trial, were expected to need mechanical ventilation for more than 48 hours and were receiving enteral nutrition exclusively by NG tube were eligible. We enrolled 69 patients and assigned 35 to PL-148 and 34 to saline. We randomly allocated saline or PL-148 for four alternating 7-week blocks, with staff blinded to the solution. The primary outcome was the proportion of patients with GI feeding intolerance, defined as high gastric residual volume (GRV), diarrhoea or vomiting while receiving NG feeding in the ICU. The proportions of patients with each of high GRV, diarrhoea and vomiting were secondary outcomes. In the PL-148 group, 21 of 35 patients (60.0%) developed GI feeding intolerance, compared with 22 of 34 patients (64.7%) in the saline group (odds ratio [OR], 0.82; 95% CI, 0.31-2.17; P = 0.69). A high GRV was seen in four of 35 patients (11.4%) in the PL-148 group, and in 11 of 34 patients (32.4%) in the saline group (OR, 0.27; 95% CI, 0.08-0.96; P = 0.04). Among mechanically ventilated patients receiving NG feeding, the use of PL-148, compared with saline, did not reduce the proportion of patients developing GI feeding intolerance, but was associated with a decreased incidence of high GRV.

  19. Thoracostomy tubes: A comprehensive review of complications and related topics

    PubMed Central

    Kwiatt, Michael; Tarbox, Abigail; Seamon, Mark J.; Swaroop, Mamta; Cipolla, James; Allen, Charles; Hallenbeck, Stacinoel; Davido, H. Tracy; Lindsey, David E.; Doraiswamy, Vijay A.; Galwankar, Sagar; Tulman, David; Latchana, Nicholas; Papadimos, Thomas J.; Cook, Charles H.; Stawicki, Stanislaw P.

    2014-01-01

    Tube thoracostomy (TT) placement belongs among the most commonly performed procedures. Despite many benefits of TT drainage, potential for significant morbidity and mortality exists. Abdominal or thoracic injury, fistula formation and vascular trauma are among the most serious, but more common complications such as recurrent pneumothorax, insertion site infection and nonfunctioning or malpositioned TT also represent a significant source of morbidity and treatment cost. Awareness of potential complications and familiarity with associated preventive, diagnostic and treatment strategies are fundamental to satisfactory patient outcomes. This review focuses on chest tube complications and related topics, with emphasis on prevention and problem-oriented approaches to diagnosis and treatment. The authors hope that this manuscript will serve as a valuable foundation for those who wish to become adept at the management of chest tubes. PMID:25024942

  20. Use of proton pump inhibitors is associated with increased mortality due to nosocomial pneumonia in bedridden patients receiving tube feeding.

    PubMed

    Hamai, Kosuke; Iwamoto, Hiroshi; Ohshimo, Shinichiro; Wakabayashi, Yu; Ihara, Daisuke; Fujitaka, Kazunori; Hamada, Hironobu; Ono, Koichi; Hattori, Noboru

    2018-05-22

    To investigate the association between the use of proton pump inhibitors (PPI) and nosocomial pneumonia and gastrointestinal bleeding in bedridden patients receiving tube feeding. A total of 116 bedridden hospitalized patients receiving tube feeding, of which 80 were supported by percutaneous endoscopic gastrostomy and 36 by nasogastric tube, were included in the present study. The patients were divided into two groups: 62 patients treated with PPI (PPI group) and 54 patients without PPI (non-PPI group). Mortality due to nosocomial pneumonia was evaluated using the Kaplan-Meier approach and the log-rank test. A total of 36 patients (31%) died of nosocomial pneumonia during the observation period; the mortality rate due to nosocomial pneumonia was significantly higher in the PPI group than in the non-PPI group (P = 0.0395). Cox proportional hazard analysis showed that the use of PPI and lower levels of serum albumin were independent predictors of 2-year mortality due to nosocomial pneumonia. Gastrointestinal bleeding was observed in four patients in the non-PPI group (7.7%) and in one patient in the PPI group (1.6%); there was no significant difference between the two groups. The use of PPI in bedridden tube-fed patients was independently associated with mortality due to nosocomial pneumonia, and the PPI group had a non-significant lower incidence of gastrointestinal bleeding than the non-PPI group. Geriatr Gerontol Int 2018; ••: ••-••. © 2018 The Authors Geriatrics & Gerontology International published by John Wiley & Sons Australia, Ltd on behalf of Japan Geriatrics Society.

  1. Deliberate self-harming application of superglue in the nose: case report and literature review.

    PubMed

    Tikka, T; Al Abduwani, J; Costello, D

    2015-01-01

    Accidental and non-accidental applications of superglue in the ear, nose and oral cavity have been reported previously. Surgical removal of glue from the nose is the current practice. This paper reports the case of an 18-year-old female, who presented with complete bilateral nasal occlusion due to deliberate self-application of superglue in both nostrils to avoid nasogastric tube insertion. Removal of glue was accomplished with a combination of local anaesthetic cream and acetone-soaked cotton buds, which caused only minimal discomfort to the patient. All traces of glue disappeared within 10 days, without causing damage to the nasal mucosa, nasal blockage or pain. To the best of our knowledge, this is the first case report of deliberate self-application of superglue in the nose. A successful non-surgical management option for the removal of glue from the nose is introduced.

  2. Enhancement of acoustical performance of hollow tube sound absorber

    NASA Astrophysics Data System (ADS)

    Putra, Azma; Khair, Fazlin Abd; Nor, Mohd Jailani Mohd

    2016-03-01

    This paper presents acoustical performance of hollow structures utilizing the recycled lollipop sticks as acoustic absorbers. The hollow cross section of the structures is arranged facing the sound incidence. The effects of different length of the sticks and air gap on the acoustical performance are studied. The absorption coefficient was measured using impedance tube method. Here it is found that improvement on the sound absorption performance is achieved by introducing natural kapok fiber inserted into the void between the hollow structures. Results reveal that by inserting the kapok fibers, both the absorption bandwidth and the absorption coefficient increase. For test sample backed by a rigid surface, best performance of sound absorption is obtained for fibers inserted at the front and back sides of the absorber. And for the case of test sample with air gap, this is achieved for fibers introduced only at the back side of the absorber.

  3. Morphologic three-dimensional scanning of fallopian tubes to assist ovarian cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Madore, Wendy-Julie; De Montigny, Etienne; Deschênes, Andréanne; Benboujja, Fouzi; Leduc, Mikaël; Mes-Masson, Anne-Marie; Provencher, Diane M.; Rahimi, Kurosh; Boudoux, Caroline; Godbout, Nicolas

    2017-07-01

    The majority of high-grade serous ovarian cancers is now believed to originate in the fallopian tubes. Therefore, current practices include the pathological examination of excised fallopian tubes. Detection of tumors in the fallopian tubes using current clinical approaches remains difficult but is of critical importance to achieve accurate staging and diagnosis. Here, we present an intraoperative imaging system for the detection of human fallopian tube lesions. The system is based on optical coherence tomography (OCT) to access subepithelial tissue architecture. To demonstrate that OCT could identify lesions, we analyzed 180 OCT volumes taken from five different ovarian lesions and from healthy fallopian tubes, and compared them to standard pathological review. We demonstrated that qualitative features could be matched to pathological conditions. We then determined the feasibility of intraluminal imaging of intact human fallopian tubes by building a dedicated endoscopic single-fiber OCT probe to access the mucosal layer inside freshly excised specimens from five patients undergoing prophylactic surgeries. The probe insertion into the lumen acquired images over the entire length of the tubes without damaging the mucosa, providing the first OCT images of intact human fallopian tubes.

  4. [Use of the Pentax-AWS videolaryngoscope for bougie-assisted exchange of tracheal tubes].

    PubMed

    Kishii, Miki; Asai, Takashi; Nagata, Atsushi; Shingu, Koh

    2009-06-01

    A gum elastic bougie can be useful for tube exchange. One major problem with this technique is that it may not possible to pass a new tube over the bougie into the trachea, because the tip of the tube can collide with tissues around the glottis. We report a case in which tube exchange using the bougie was difficult, but the Pentax-AWS videolaryngoscope enabled tracheal intubation. In a 62-year-old trauma patient with head and neck stabilized using a Halo vest, was scheduled for emergency fixation of the neck. Exchange of a polyvinylchloride tube to a reinforced tube was planned. A bougie was passed through the old tube, removing the tube, and a new tube was advanced over the bougie, but it was impossible to advance the tube into the trachea. Insertion of a Macintosh laryngoscope did not enable intubation. The new tube was removed from the bougie, attached to the Pentax-AWS videolaryngoscope, and the tube (with the Pentax-AWS) was passed over the bougie. Although it was not possible to see the glottis with the Pentax-AWS, the tube was easily advanced over the bougie into the trachea. Operation went on uneventfully. We believe that, when it is difficult to advance a tracheal tube over a tube exchanger, the use of the Pentax-AWS may facilitate intubation.

  5. 18-gauge needle cap as adjunct to prevent kinking of endotracheal tube.

    PubMed

    Chan, Fuan Chiang; Kawamoto, Henry K; Bradley, James P

    2012-11-01

    A self-retaining Dingman mouth retractor is widely used to keep the mouth open during cleft palate and intraoral surgery. The airway is at risk of being crushed or occluded as the gag (tongue plate) of the Dingman mouth retractor is being pushed against the endotracheal tube.Kinking of the endotracheal tube between the teeth and Dingman mouth retractor has been reported even with the oral Ring-Adair-Elwyn or flexometallic or armored endotracheal tubes. To minimize kinking of the endotracheal tube and its consequent complications, we routinely insert an 18-gauge needle cap at the potential space between the teeth and the tongue plate (gag) of the Dingman mouth retractor, which is situated lateral to the endotracheal tube. In our experience of approximately 5000 intraoral cases using a Dingman mouth retractor and 18-gauge needle cap, we have not had any tooth avulsion or aspiration of the 18-gauge foreign body while maintaining a consistent and secured airway during cleft palate and intraoral surgery.

  6. What is the full range of medical and surgical treatments available for patients with Eustachian tube dysfunction?

    PubMed

    Adil, Eelam; Poe, Dennis

    2014-02-01

    To present the current medical and surgical treatment options for Eustachian tube dysfunction. Balloon dilation or microdebrider Eustachian tuboplasty are feasible treatment options for patients with refractory dilatory dysfunction as an alternative to tympanostomy tube placement. There is increasing evidence that repair of patulous Eustachian tubes by the insertion of a shim or fat graft reconstruction within the lumen of the Eustachian tube orifice may be effective. In patients with Eustachian tube dysfunction that is refractory to medical management, newer surgical techniques may provide symptomatic relief with a reasonable duration. Continued basic science research into the cause of dysfunction, the mechanisms of benefit from intervention and long-term clinical outcomes are necessary.

  7. Successful late management of spontaneous esophageal rupture using T-tube mediastinoabdominal drainage.

    PubMed

    Ojima, H; Kuwano, H; Sasaki, S; Fujisawa, T; Ishibashi, Y

    2001-08-01

    Spontaneous esophageal rupture is extremely rare, and early symptoms of the disease are similar to those of emergency diseases of the chest and abdomen. The diagnosis and treatments are often delayed, resulting in an unfavorable outcome in some cases. We performed improved T-tube drainage for spontaneous esophageal rupture in 5 patients between 1995 and 1999. Our improved method was a modified procedure of the reported method of Abbott et al, as follows: a T-tube was inserted into the esophagus. A separate stab incision was made in the abdominal wall, and the long limb of the T-tube was brought out through this incision ensuring that the course of the T-tube intra-abdominally was short and straight, with some slack to allow for postoperative abdominal distension. An advantage of this method was that it facilitated healing of the fistula after removal of the T-tube. All patients were treated with a satisfactory outcome. This improved T-tube drainage was technically very easy and safe method for spontaneous esophageal rupture in severe cases.

  8. Peritonitis following percutaneous gastrostomy tube insertions in children.

    PubMed

    Dookhoo, Leema; Mahant, Sanjay; Parra, Dimitri A; John, Philip R; Amaral, Joao G; Connolly, Bairbre L

    2016-09-01

    Percutaneous retrograde gastrostomy has a high success rate, low morbidity, and can be performed under different levels of sedation or local anesthesia in children. Despite its favourable safety profile, major complications can occur. Few studies have examined peritonitis following percutaneous retrograde gastrostomy in children. To identify potential risk factors and variables influencing the development and early diagnosis of peritonitis following percutaneous retrograde gastrostomy. We conducted a retrospective case-control study of children who developed peritonitis within 7 days of percutaneous retrograde gastrostomy between 2003 and 2012. From the 1,504 patients who underwent percutaneous retrograde gastrostomy, patients who developed peritonitis (group 1) were matched by closest date of procedure to those without peritonitis (group 2). Peritonitis was defined according to recognized clinical criteria. Demographic, clinical, procedural, management and outcomes data were collected. Thirty-eight of 1,504 children (2.5%; 95% confidence interval, 1.8-3.5) who underwent percutaneous retrograde gastrostomy developed peritonitis ≤7 days post procedure (group 1). Fever (89%), irritability (63%) and abdominal pain (55%) occurred on presentation of peritonitis. Group 1 patients were all treated with antibiotics; 41% underwent additional interventions: tube readjustments (8%), aspiration of pneumoperitoneum (23%), laparotomy (10%) and intensive care unit admission (10%). In group 1, enteral feeds started on average 3 days later and patients were discharged 5 days later than patients in group 2. There were two deaths not directly related to peritonitis. Neither age, gender, weight, underlying diagnoses nor operator was identified as a risk factor. Peritonitis following percutaneous retrograde gastrostomy in children occurs in approximately 2.5% of cases. No risk factors for its development were identified. Medical management is usually sufficient for a good outcome

  9. Using HFMEA to assess potential for patient harm from tubing misconnections.

    PubMed

    Kimehi-Woods, Judy; Shultz, John P

    2006-07-01

    Reported cases of tubing misconnections and other tubing errors prompted Columbus Children's Hospital to study their potential for harm in its patient population. A Health Failure Mode and Effects Analysis (HFMEA) was conducted in October 2004 to determine the risks inherent in the use and labeling of various enteral, parenteral, and other tubing types in patient care and the potential for patient harm. An assessment of the practice culture revealed considerable variability among nurses and respiratory therapists within and between units. Work on an HFMEA culminated in recommendations of risk reduction strategies. These included standardizing the process of labeling of tubing throughout the organization, developing an online pictorial catalog to list available tubing supplies with all aliases used by staff, and conducting an inventory of all supplies to identify products that need to be purchased or discontinued. Three groups are working on implementing each of the recommendations. Most of the results already realized occurred in labeling of tubing. The pediatric intensive care unit labels all tubing with infused medications 85% of the time; tubings inserted during surgery or in interventional radiology are labeled 53% and 93% of the time. Pocket-size cards with printed labels were tested in three units. This proactive risk assessment project has identified failure modes and possible causes and solutions; several recommendations have been implemented. No tubing misconnections have been reported.

  10. Enhancement of acoustical performance of hollow tube sound absorber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Putra, Azma, E-mail: azma.putra@utem.edu.my; Khair, Fazlin Abd, E-mail: fazlinabdkhair@student.utem.edu.my; Nor, Mohd Jailani Mohd, E-mail: jai@utem.edu.my

    This paper presents acoustical performance of hollow structures utilizing the recycled lollipop sticks as acoustic absorbers. The hollow cross section of the structures is arranged facing the sound incidence. The effects of different length of the sticks and air gap on the acoustical performance are studied. The absorption coefficient was measured using impedance tube method. Here it is found that improvement on the sound absorption performance is achieved by introducing natural kapok fiber inserted into the void between the hollow structures. Results reveal that by inserting the kapok fibers, both the absorption bandwidth and the absorption coefficient increase. For testmore » sample backed by a rigid surface, best performance of sound absorption is obtained for fibers inserted at the front and back sides of the absorber. And for the case of test sample with air gap, this is achieved for fibers introduced only at the back side of the absorber.« less

  11. Comparison between orogastric tube/bougie and a suction calibration system for effects on operative duration, staple-line corkscrewing, and esophageal perforation during laparoscopic sleeve gastrectomy.

    PubMed

    Gagner, Michel; Huang, Rose Y

    2016-04-01

    Placement of a bougie for sleeve sizing during laparoscopic sleeve gastrectomy (LSG) is recommended. We compared this standard with a suction calibration system (SCS) that performs all functions with one insertion, and measured each step's duration. Primary LSG was performed using a bougie and SCS in alternating order. Number of tube movements to achieve optimal placement, durations of decompression, leak testing, and overall operative time, and remnant linear measurements were obtained. LSG was performed in 26 patients (15 women, 11 men; mean age 36.8 years; mean BMI 45.3 kg/m(2)). The mean number of tube movements was significantly greater for the bougie than for the SCS (8.13 vs. 3.58; p < 0.0001). Percent reductions achieved using the SCS were: time to full decompression of the stomach, 62% (21 vs. 8 s; p < 0.138); tube placement, 51% (101 vs. 49 s; p < 0.0001); leak testing, 78% (119 vs. 26 s; p < 0.0003); and mean operative duration (from tube insertion to end of stapling), 21% (875 vs. 697 s; p < 0.019). Variance of the staple-line distance, measured from the greater curvature to the staple line, was 1.64 and 0.92 for the bougie and SCS, respectively, indicating a reduction in corkscrewing, for a 43.9% straighter sleeve. SCS maintained the gastric wall in place, thereby preventing corkscrewing, and reducing total operating time. Reducing the number of tube insertions may prevent esophageal damage and accidental tube stapling.

  12. The paradigm of eave tubes: scaling up house improvement and optimizing insecticide delivery against disease-transmitting mosquitoes.

    PubMed

    Okumu, Fredros

    2017-05-19

    Control of mosquito-borne diseases is greatly compromised by spread of insecticide resistance, high implementation costs and sub-optimal compliance among users. Improved housing has potential to reduce malaria transmission nearly as much as long-lasting insecticide-treated nets (LLINs), while also preventing other arthropod-borne diseases and improving overall well-being. Yet, it is hardly promoted as mainstream intervention, partly because of high costs, minimal communal benefits to people in non-improved houses, and low scalability. By exploiting biological observations of mosquito behaviours around dwellings, scientists have developed a new approach that integrates effective vector control into housing developments. The technique involves blocking eave spaces in local houses, leaving a few cylindrical holes into which plastic tubes with insecticide-laden electrostatic nettings are inserted. Where houses already have blocked eaves, these cylindrical holes are drilled and the tubes inserted. The eave tube technology, as it is called, is an innovative new approach for implementing housing improvements, by creating a new scalable product that can be integrated in houses during or after construction. It takes away insecticides from proximity of users, and instead puts them where mosquitoes are most likely to enter houses, thereby reducing insecticidal exposure among household occupants, while maximizing exposure of mosquitoes. This way, lower quantities of insecticides are used, better house ventilation achieved, intervention costs reduced, and mass communal benefits achieved even were vectors are resistant to similar insecticides when delivered conventionally. There are however still some critical pieces missing, notably epidemiological, social and economic evidence that the above assertions are true and sustainable. Besides, there also some technical limitations to be considered, namely: (1) need for extensive house modifications before eave tubes are inserted, (2

  13. Common agents used to unblock blood clots within tympanostomy tubes: an ex vivo study and review of literature.

    PubMed

    Burke, Emily L; Walvekar, Rohan R; Lin, James; Hagan, Joseph; Kluka, Evelyn A

    2009-12-01

    To determine the efficacy of common solutions used to dissolve blood clots blocking tympanostomy tubes (TTs) of differing lengths and diameters. An ex vivo experimental study. Ear models were built by the study investigator. Tympanostomy tubes were inserted into the models and blocked with blood clots. Test solutions were applied to the blood clots, and time for clearance was recorded via microscopic visual confirmation. Richards T-tube had higher odds of unclogging than collar button tubes (odds ratio: 2.37, 95% confidence intervals 1.02-5.54, p=0.042). Vinegar and 3% hydrogen peroxide were most effective for Richards T-tubes and collar button tubes, respectively. Common solutions (vinegar and hydrogen peroxide) were more effective than antibiotic drops in clearing blood clot blocking TTs.

  14. Tube introducer and modified Celestin tube for use in palliative intubation of oesophagogastric neoplasms at fibreoptic endoscopy.

    PubMed Central

    Atkinson, M; Ferguson, R; Parker, G C

    1978-01-01

    A new method for palliative intubation of inoperable neoplasms at or near the cardia is described. A guidewire is passed through the stricture, which is dilated using Eder Puestow metal olive dilators. The tube to be inserted is mounted on an introducer, which grips its distal end from inside, and is slid into position along the wire under radiological control. Twenty-five patients have been intubated with one death directly resulting from the procedure. The method provides a simple and relatively safe means of relieving dysphagia and improving nutrition. Images Fig. 2 PMID:79517

  15. Transient Tachypnea of the Newborn (TTN)

    MedlinePlus

    ... newborn receives IV fluids. Sometimes babies can take breast milk or formula through a nasogastric (NG) or orogastric ( ... of these tubes, ask the doctor about providing breast milk for your baby. Symptoms of transient tachypnea usually ...

  16. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    PubMed

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P < 0.05). The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  17. Effects of tubing length and coupling method on hearing threshold and real-ear to coupler difference measures.

    PubMed

    Gustafson, Samantha; Pittman, Andrea; Fanning, Robert

    2013-06-01

    This tutorial demonstrates the effects of tubing length and coupling type (i.e., foam tip or personal earmold) on hearing threshold and real-ear-to-coupler difference (RECD) measures. Hearing thresholds from 0.25 kHz through 8 kHz are reported at various tubing lengths for 28 normal-hearing adults between the ages of 22 and 31 years. RECD values are reported for 14 of the adults. All measures were made with an insert earphone coupled to a standard foam tip and with an insert earphone coupled to each participant's personal earmold. Threshold and RECD measures obtained with a personal earmold were significantly different from those obtained with a foam tip on repeated measures analyses of variance. One-sample t tests showed these differences to vary systematically with increasing tubing length, with the largest average differences (7-8 dB) occurring at 4 kHz. This systematic examination demonstrates the equal and opposite effects of tubing length on threshold and acoustic measures. Specifically, as tubing length increased, sound pressure level in the ear canal decreased, affecting both hearing thresholds and the real-ear portion of the RECDs. This demonstration shows that when the same coupling method is used to obtain the hearing thresholds and RECD, equal and accurate estimates of real-ear sound pressure level are obtained.

  18. Middle finger length-based tracheal intubation depth improves the rate of appropriate tube placement in children.

    PubMed

    Zhou, Qing-he; Xiao, Wang-pin; Zhou, Hong-mei

    2015-11-01

    It is challenging for anesthetists to determine the optimal tracheal intubation depth in children. We hypothesize that a measure three times the length of the middle finger can be used for predicting tracheal tube depth in children. Eighty-six children (4-14 years of age) were included in this study. After the children were anesthetized, a fiberoptic bronchoscope (FOB) was inserted into the trachea, the lengths from the upper incisor teeth to carina and vocal cords were measured, and a suitably sized cuffed tracheal tube was inserted into the trachea. Age-based and middle finger length-based formulas were used to determine the tracheal intubation depth. All 86 children enrolled were included in this study. Compared with the age-based intubation, the rate of appropriate tube placement was higher for middle finger length-based intubation (88.37% vs 66.28%, P = 0.001). The proximal intubation rate was lower in middle finger length-based intubation (4.65% vs 32.56%, P < 0.001). There was only weak evidence for a difference in the distal intubation rate between the two methods (6.97% vs 1.16%, P = 0.054). The correlation coefficient between middle finger length and optimal tracheal tube depth was larger than that between age and optimal tracheal tube depth (0.883 vs 0.845). Our data indicate that the appropriate tube placement rate can be improved by using three times the middle finger length as the tracheal intubation depth in children. © 2015 John Wiley & Sons Ltd.

  19. Thermal analysis on x-ray tube for exhaust process

    NASA Astrophysics Data System (ADS)

    Kumar, Rakesh; Rao Ratnala, Srinivas; Veeresh Kumar, G. B.; Shivakumar Gouda, P. S.

    2018-02-01

    It is great importance in the use of X-rays for medical purposes that the dose given to both the patient and the operator is carefully controlled. There are many types of the X- ray tubes used for different applications based on their capacity and power supplied. In present thesis maxi ray 165 tube is analysed for thermal exhaust processes with ±5% accuracy. Exhaust process is usually done to remove all the air particles and to degasify the insert under high vacuum at 2e-05Torr. The tube glass is made up of Pyrex material, 95%Tungsten and 5%rhenium is used as target material for which the melting point temperature is 3350°C. Various materials are used for various parts; during the operation of X- ray tube these waste gases are released due to high temperature which in turn disturbs the flow of electrons. Thus, before using the X-ray tube for practical applications it has to undergo exhaust processes. Initially we build MX 165 model to carry out thermal analysis, and then we simulate the bearing temperature profiles with FE model to match with test results with ±5%accuracy. At last implement the critical protocols required for manufacturing processes like MF Heating, E-beam, Seasoning and FT.

  20. Evaluation of the tightness of contact between 
limbal sclera tunnel and tube following Ahmed 
glaucoma valve implantation.

    PubMed

    Holló, Gábor; Naghizadeh, Farzaneh

    2013-01-01

    To investigate whether the tightness of contact between the tube and the limbal sclera tunnel can be evaluated with high-magnification anterior segment optical coherence tomography (OCT) imaging following Ahmed glaucoma valve implantation. Tightness between the tube and the limbal sclera tunnel was investigated with the CAM-L cornea lens adapter of the Optovue Fourier-domain OCT (RTVue-OCT) for 21 uncomplicated Ahmed glaucoma valves implanted in 20 eyes of 19 patients with glaucoma. Nineteen valves were implanted 4 to 124 months earlier (late postoperative cases) and 2 valves 1 day prior to the imaging (early postoperative cases). All valves were introduced into the anterior chamber via a limbal sclera tunnel. The limbal intratunnel part of the tube was successfully imaged in all but 2 cases where an additional full-thickness sclera patch was used. In 14 cases, the contact was tight without tube compression. In 
5 cases, the tube was partially compressed but remained open in the limbal sclera tunnel, and redilated behind the limbus. No case with loose contact or peritubular filtration was seen. The posterior run of the tube was successfully imaged in all 19 cases without a full-thickness sclera patch. High-magnification imaging with the CAM- L anterior segment adapter of the RTVue-OCT allows detailed examination of the limbal insertion area of tubes in both the early and late postoperative periods. Therefore this method may potentially be applied for detection of complications related to tube insertion after glaucoma drainage device surgery.

  1. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    PubMed Central

    Murphy, William J.; Fackler, Cameron J.; Berger, Elliott H.; Shaw, Peter B.; Stergar, Mike

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL. PMID:26356380

  2. Differential lung ventilation via tracheostomy using two endotracheal tubes in an infant: a case report.

    PubMed

    Demirkol, Demet; Ataman, Yasemin; Gündoğdu, Gökhan

    2017-09-08

    This case report presents differential lung ventilation in an infant. The aim is to define an alternative technique for performing differential lung ventilation in children. To the best of our knowledge, this is the first report of this kind. A 4.2-kg, 2.5-month-old Asian boy was referred to our facility with refractory hypoxemia and hypercarbia due to asymmetric lung disease with atelectasis of the left lung and hyperinflation of the right lung. He was unresponsive to conventional ventilator strategies; different ventilator settings were required. To perform differential lung ventilation, two separate single-lumen endotracheal tubes were inserted into the main bronchus of each lung by tracheotomy; the tracheal tubes were attached to discrete ventilators. The left lung was ventilated with a lung salvage strategy using high-frequency oscillatory ventilation, and the right lung was ventilated with a lung-protective strategy using pressure-regulated volume control mode. Differential lung ventilation was performed successfully with this technique without complications. Differential lung ventilation may be a lifesaving procedure in select patients who have asymmetric lung disease. Inserting two single-lumen endotracheal tubes via tracheotomy for differential lung ventilation can be an effective and safe alternative method.

  3. Exogenous Lipoid Pneumonia in Laryngectomy Patients: Radiological Findings.

    PubMed

    García Latorre, Raquel; Rodríguez Díaz, Ricardo; Barrios Barreto, Deisy; Ayala Carbonero, Ana; García Gómez-Muriel, María Isabel; Gorospe Sarasúa, Luis

    2015-07-01

    Exogenous lipoid pneumonia (ELP) is a rare (incidence 1.0%-2.5%), often under-diagnosed disease, caused by the aspiration and accumulation of exogenous lipids within the pulmonary alveoli. Various cases have been described due to inhalation of lubricants via the nasal passages and oropharynx, aspiration of mineral oils in laxatives in patients with eating disorders, application of lip gloss, occupational exposure to liquid paraffin or mineral oils ("fire-eaters", industrial use in washing of machinery, automobile workshops, plastic paints, etc.) and application of Vaseline during the insertion of nasogastric tubes and in the care of tracheotomy patients. ELP usually presents radiologically as areas of low-attenuation peribronchial consolidation and ground glass opacities, with a predominantly bibasal distribution. We present 5 cases of long-standing laryngectomy patients diagnosed with ELP who admitted using Vaseline in their tracheal stoma care. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  4. Disappearance of a stutter shortly before death.

    PubMed

    Duong, Phuc H; Zulian, Gilbert B

    2007-01-01

    A patient with a stutter caused by the trauma of the death of a loved one was able to recover normal speech 1 week before her death, which resulted from intestinal obstruction caused by ovarian cancer. The stutter appeared to have been overcome using a combination therapy of sophrology, self-regulation, and drug therapy. During a genuine resilience process, the patient was able to overcome an earlier existential fracture. In this final phase of life, health professionals and the family fully respected the patient's independence to remain in control of events. She repeatedly refused to have a nasogastric tube inserted to extract fecal matter from the stomach. This patient consequently repossessed her own language of expression in a body that was shattered by cancerous illness and the consequences of treatments. She thus managed to find a successful balance between the body, the spirit, and the brain.

  5. SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrero, A; Chen, B; Huang, A

    Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previouslymore » developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and

  6. Ear tube insertion

    MedlinePlus

    ... eardrum may cause some hearing loss. But most children do not have long-term damage to their hearing or speech, even when the ... not go away with treatment, or if a child has many ear infections ... or that damages nearby nerves Injury to the ear after sudden ...

  7. Use of the Crawford tube for symptomatic epiphora without nasolacrimal obstruction.

    PubMed

    Tong, Nyu-Xia; Zhao, Ying-Ying; Jin, Xiu-Ming

    2016-01-01

    To evaluate the effectiveness of the Crawford tube in treating symptomatic epiphora without nasolacrimal obstruction. A protocol was adopted for the management of symptomatic epiphora without nasolacrimal obstruction. Patients who suffered symptomatic epiphora without nasolacrimal obstruction in both eyes were included in the study. One eye was treated with Crawford tube intubation and the other eye was treated with medication therapy. Degree of watering, patient satisfaction, and symptomatic improvement were carefully evaluated by one of the authors at the end of the follow-up period, after Crawford tube removal, to ascertain functional results. Thirty-seven adult patients (37 eyes) underwent Crawford tube intubation for functional epiphora. The mean follow-up time after removal of the tube was 14.8±4.8mo. The procedure was an overall success in 28 eyes (75.7%), with symptoms improving significantly. Two eyes (5.4%) were relieved of indoor epiphora, two (5.4%) had minimal epiphora outdoors, but only with wind or cold, and five (13.5%) continued to experience tearing both indoors and outdoors. Thirty of the patients (81%) expressed satisfaction with the procedure. Crawford tube insertion is an effective, safe, simple, and relatively noninvasive treatment strategy for functional lacrimal system obstruction.

  8. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    PubMed Central

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001), but the trend of pain score between groups was not significantly different (P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group (P < 0.05). Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF. PMID:29387121

  9. Using a Bedside Video-assisted Test Tube Test to Assess Stoma Viability: A Report of 4 Cases.

    PubMed

    Ahmad, Sarwat; Turner, Keli; Shah, Paulesh; Diaz, Jose

    2016-07-01

    Mucosal discoloration of an intestinal stoma may indicate self-limited venous congestion or necrosis necessitating operative revision. A common bedside technique to assess stoma viability is the "test tube test". A clear tube is inserted into the stoma and a hand-held light is used to assess the color of the stoma. A technique (video-assisted test tube test [VATTT]) developed by the authors utilizes a standard video bronchoscope inserted into a clear plastic blood collection tube to visually inspect and assess the mucosa. This technique was evaluated in 4 patients (age range 49-72 years, all critically ill) with a discolored stoma after emergency surgery. In each case, physical exam revealed ischemic mucosa at the surface either immediately after surgery or after worsening hypotension weeks later. Serial test tube test assessments were ambiguous when trying to assess deeper mucosa. The VATTT assessment showed viable pink mucosa beneath the surface and until the fascia was revealed in 3 patients. One (1) patient had mucosal ischemia down to the fascia, which prompted operative revision of the stoma. The new stoma was assessed with a VATTT and was viable for the entire length of the stoma. VATTT provided an enhanced, magnified, and clearer way to visually assess stoma viability in the postoperative period that can be performed at the bedside with no adverse events. It may prevent unnecessary relaparotomy or enable earlier diagnosis of deep ostomy necrosis. Validity and reliability studies are warranted.

  10. Experimental Attempts for Deep Insertion in Ultrasonically Forced Insertion Process

    NASA Astrophysics Data System (ADS)

    Ono, Satoshi; Aoyagi, Manabu; Tamura, Hideki; Takano, Takehiro

    2011-07-01

    In this paper, we describe two attempts of obtaining deep insertion in an ultrasonically forced insertion (USFI) process. One was to correct the inclination of an inserted rod by passively generated bending vibrations. The inclination causes a partial plastic deformation, which decreases the holding power of processing materials. Two types of horn with grooves for excitation of bending vibrations were examined. The other was to make differences in vibration velocity and the phase of a rod and a metal plate by damping the vibration of a metal plate by using a rubber sheet. As results, the attempts proposed in this study were confirmed to be effective to obtain a deep insertion.

  11. Syringo-Subarachnoid-Peritoneal Shunt Using T-Tube for Treatment of Post-Traumatic Syringomyelia

    PubMed Central

    Kim, Seon-Hwan; Youm, Jin-Young; Kwon, Hyon-Jo

    2012-01-01

    Various surgical procedures for the treatment of post-traumatic syringomyelia have been introduced recently, but most surgical strategies have been unreliable. We introduce the concept and technique of a new shunting procedure, syringo-subarachnoid-peritoneal shunt. A 54-year-old patient presented to our hospital with a progressive impairment of motion and position sense on the right side. Sixteen years before this admission, he had been treated by decompressive laminectomy for a burst fracture of L1. On his recent admission, magnetic resonance (MR) imaging studies of the whole spine revealed the presence of a huge syrinx extending from the medulla to the L1 vertebral level. We performed a syringo-subarachnoid-peritoneal shunt, including insertion of a T-tube into the syrinx, subarachnoid space and peritoneal cavity. Clinical manifestations and radiological findings improved after the operation. The syringo-subarachnoid-peritoneal shunt has several advantages. First, fluid can communicate freely between the syrinx, the subarachnoid space, and the peritoneal cavity. Secondly, we can prevent shunt catheter from migrating because dural anchoring of the T-tube is easy. Finally, we can perform shunt revision easily, because only one arm of the T-tube is inserted into the intraspinal syringx cavity. We think that this procedure is the most beneficial method among the various shunting procedures. PMID:22993681

  12. The honey insertion cladding to improve the sensitivity of temperature polymer optical fiber sensor

    NASA Astrophysics Data System (ADS)

    Arwani, M.; Kuswanto, H.

    2018-04-01

    The sensitivity of temperature polymer optical fiber (POF) sensor has been studied. Part of cladding (9 cm) was substituted with honey. Polymer cladding was stripped mechanically and the honey inserted into the tube. Plastic gel closed the two end sides of the tubes. The optical power output was detected by Optical Power Meter (OPM). Honey cladding and temperature changing effect to the internal reflection and optical fiber output intensity. Highest output intensity changing at 20°C was shown by optical fiber coated by longan honey as cladding. The range of 10-50° C, as the rise of surroundings temperature, the attenuation was getting smaller. Best sensitivity was fiber with sensing part coated by Longan honey. Best linearity was sensing fiber with sensing part coated by Pracimantoro honey.

  13. Tube-in-tube thermophotovoltaic generator

    DOEpatents

    Ashcroft, J.; Campbell, B.; DePoy, D.

    1998-06-30

    A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell. 8 figs.

  14. Tube-in-tube thermophotovoltaic generator

    DOEpatents

    Ashcroft, John; Campbell, Brian; DePoy, David

    1998-01-01

    A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell.

  15. Histopathology of tympanic membranes from patients with ventilation tubes.

    PubMed

    Oktay, Mehmet Faruk; Tansuker, Hasan Deniz; Fukushima, Hisaki; Paparella, Michael M; Schachern, Patricia A; Cureoglu, Sebahattin

    2018-06-01

    To evaluate the histopathologic changes in tympanic membranes (TMs) with ventilation tubes (VTs). In this retrospective human temporal bone study our overall study group included 4 subgroups of TMs from deceased donors as follows: 24 with a history of VT insertion for chronic otitis media with effusion (COME-VT); 5 with a history of VT insertion for Meniere's disease (MD-VT); 33 without a history of VT insertion for chronic otitis media with effusion (COME); and 14 without a history of VT insertion for Meniere's disease (MD). We classified the extent of migration of the outer keratinized squamous epithelium onto the inner surface of TM perforations and noted the presence and location of tympanosclerosis, of atrophy, of perforation, and/or of cholesteatoma formation. Tympanosclerosis occurred in 14/24 TMs in the COME-VT subgroup; 2/5, MD-VT; 7/33, COME; and 0/14, MD. The VT insertion site was mostly in the anteroinferior (63%) quadrant of the TM; tympanosclerosis occurred more frequently in the posteroinferior (42%) and posterosuperior (33%) quadrants. We found no significant correlation between the location of tympanosclerosis and the VT insertion site (P>0.05). Atrophy occurred in 7/24 TMs in the COME-VT subgroup; 3/5, MD-VT; 8/33, COME; and 2/14, MD. We found no significant correlation between the location of atrophy and the VT insertion site; however, atrophy was located mostly in the anteroinferior quadrant (one of the most common VT insertion sites) of the TM. Regarding the ingrowth of keratinized epithelium, the mucocutanous junction was detected at any point at the inner surface of the TM in 50% of the specimens. We observed intratympanic cholesteatoma formation in 2/24 TMs in the COME-VT subgroup. TM changes due to VT insertion are more common than previously realized. Meticulous otomicroscopic evaluation of the TM is necessary during tympanomastoidectomies in order to prevent the intratympanic inclusion pearls and squamous epithelial ingrowth to prevent

  16. Saline-filled cuffs help prevent laser-induced polyvinylchloride endotracheal tube fires.

    PubMed

    Sosis, M B; Dillon, F X

    1991-02-01

    To determine whether the filling of tracheal tube cuffs with saline would decrease their combustibility during laser surgery, 20 polyvinylchloride tracheal tubes were studied. The cuffed end of each tracheal tube was inserted into the neck of an empty flask, and the tube and flask were flushed with oxygen for 5 min before cuff inflation. Ten tracheal tubes had their cuffs inflated with air, and 10 were inflated with saline. A Lasersonics LS880 CO2 laser, set to 5 W for five of each of the two types of filled cuffs and to 40 W for the other pair of five tubes, was fired continuously at the cuffs for up to 1 min. No combustion occurred at the 5-W setting. The times to cuff perforation when the laser was set at 5 W were (mean +/- SD) 1.00 +/- 0.83 and 4.21 +/- 3.91 s for the air- and saline-filled cuffs, respectively, a difference that was not statistically significant. The time to deflation of the saline-filled cuff (104.6 +/- 67.5 s) was, however, significantly longer than that of the air-filled cuff (2.59 +/- 1.97 s). When the tracheal tube cuffs were exposed to 40-W laser radiation, the cuff and adjacent tube shaft ignited in all cases when the cuffs were inflated with air, but only in one of five cases when the cuffs were filled with saline (P less than 0.05). The filling of tracheal tube cuffs with saline provides simple, moderately effective partial protection of the cuff of endotracheal tubes during CO2 laser airway surgery.

  17. Use of the silicone tracheal T-tube for tracheostenosis or tracheomalacia.

    PubMed

    Liu, H C; Wang, L S; Fahn, H J; Lee, Y C; Lu, C C; Chan, K H; Huang, M H

    1996-09-01

    Tracheobtenosib and tracheomalacia are trivial diseases. The conventional choice of managements with tracheostomy, either temporary or long-term usage, can only partially resolve the problems of airway obstruction. Silicone tracheal T-tube presents a substitute for it. We present 5 patients with tracheostenosis or tracheomalacia managed with nine procedures of long silicone Montgomery T-tube prothesis between 1984 and 1994 in VGH-Taipei. The primary diagnosis included tracheal injury (2), postintubation tracheal stenosis (2), and stenosis due to endotracheal tuberculosis (1). Three patients received a long segmental T-tube for permanent endotracheal stenting and the other two patients used T-tube insertion for temporary stenting of the trachea for 7 and 11 months, respectively, with satisfactory results. All patients got immediate benefit from the prothesis in respiration with simple postoperative care. Two patients with temporary T-tube placement had it successfully removed in 7 and 11 months, respectively. Placement of the T-tube for subglottic stenosis also protected the function of phonation. The tracheal T-tube restored airway patency reliably with good long-term results and could be the preferred management of chronic upper airway obstructive disease not amenable to surgical repair. The most common complication was airway obstruction caused by either granulations or sticky mucoid substance. Three patients and six tubes (60%) developed granulation obstruction and the average duration of granuloma formation was 7.7 months. Laser phototherapy or surgical intervention, such as tracheoplasty, with change of the T-tube was carried out for granuloma obstruction. T-tube is a good endoprothesis for tracheostenosis and tracheomalacia with minimal complication for cases of long tracheostenosis or complex tracheal injury.

  18. Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrocelli, Francesco, E-mail: francesco.petrocelli@hsanmartino.it; Salsano, Giancarlo, E-mail: giancarlo.salsano@yahoo.it; Bovio, Giulio, E-mail: giulio.bovio@hsanmartino.it

    IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriformmore » sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.« less

  19. Do financial incentives of introducing case mix reimbursement increase feeding tube use in nursing home residents?

    PubMed

    Teno, Joan M; Feng, Zhanlian; Mitchell, Susan L; Kuo, Sylvia; Intrator, Orna; Mor, Vincent

    2008-05-01

    To determine whether adoption of Medicaid case mix reimbursement is associated with greater prevalence of feeding tube use in nursing home (NH) residents. Secondary analysis of longitudinal administrative data about the prevalence of feeding tube insertion and surveys of states' adoption of case mix reimbursement. NHs in the United States. NH residents at the time of NH inspection between 1993 and 2004. Facility prevalence of feeding tubes reported at the state inspection of NHs reported in the Online Survey, Certification and Reporting database and interviews with state policy makers regarding the adoption of case mix reimbursement. Between 1993 and 2004, 16 states adopted Resource Utilization Group case mix reimbursement. States varied in the prevalence of feeding tubes in their NHs. Although the use of feeding tube increased substantially over the years of the study, once temporal trends and facility fixed effects were accounted for, case mix reimbursement was not associated with greater prevalence of feeding tube use. The adoption of Medicaid case mix reimbursement was not associated with an increase in the prevalence of feeding tube use.

  20. Speaking Tracheostomy Tube and Modified Mouthstick Stylus in a Ventilator-Dependent Patient with Spinal Cord Injury.

    PubMed

    Mitate, Eiji; Kubota, Kensuke; Ueki, Kenji; Inoue, Rumi; Inoue, Ryosuke; Momii, Kenta; Sugimori, Hiroshi; Maehara, Yoshihiko; Nakamura, Seiji

    2015-01-01

    Communication is a serious problem for patients with ventilator-dependent tetraplegia. A 73-year-old man was presented at the emergency room in cardiopulmonary arrest after falling from a height of 2 m. After successful resuscitation, fractures of the cervical spine and cervical spinal cord injury were found. Due to paralysis of the respiratory muscles, a mechanical ventilator with a tracheostomy tube was required. First, a cuffed tracheostomy tube and a speaking tracheostomy tube were inserted, and humidified oxygen was introduced via the suction line. Using these tubes, the patient could produce speech sounds, but use was limited to 10 min due to discomfort. Second, a mouthstick stylus, fixed on a mouthpiece that fits over the maxillary teeth, was used. The patient used both a communication board and a touch screen device with this mouthstick stylus. The speaking tracheostomy tube and mouthstick stylus greatly improved his ability to communicate.

  1. Middle ear findings and need for ventilation tubes among pediatric cleft lip and palate patients in northern Finland.

    PubMed

    Lehtonen, Ville; Lithovius, Riitta H; Autio, Timo J; Sándor, George K; Ylikontiola, Leena P; Harila, Virpi; Pesonen, Paula; Koskinen, Sari; Anttonen, Vuokko

    2016-04-01

    Middle ear problems are common in cleft patients. This study aimed to determine the need for ventilation tubes (VTs) and complications such as tympanic perforation and cholesteatoma. Data of 156 children with clefts managed in northern Finland spanning 15 years from 1997 to 2011 were collected from 6 hospitals. The following were recorded: birth date, gender, cleft type, surgery timing, surgery type, number of tube insertions, tube material, middle ear findings, and tube placement timing. Clefts were divided into 4 groups: cleft palate (CP), cleft lip and palate (CLP), cleft lip (CL), and submucous cleft palate. The prevalence of middle ear findings was reported. Mucous secretion was noted in 96.8% of CLP patients, 69.2% of CP patients, and 13.0% of CL patients. In all, 82.7% of study group had 1 or more VTs placed during follow-up. All CLP patients required more than 1 VT placement. A total of 94.5% of CP patients required VTs compared to 13.0% of CL patients. In the presence of residual oral nasal fistula, the mean number of tube insertions was 5.3. The prevalence of tympanic perforations in clefts was 35.9% and cholesteatoma in 2.6% of patients. CLP and isolated CP patients have frequent middle ear infections requiring multiple VT placements. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Supportive care for children with cancer. Guidelines of the Childrens Cancer Study Group. The use of nutritional therapy.

    PubMed

    Lukens, J N

    1984-01-01

    Nutritional support for children with cancer is predicated on the belief that optimal nutrition promotes tolerance of anti-neoplastic therapy and preserves immunologic responsiveness. The use of nutritional support is based on the assumption that there is effective therapy for the primary disease and that there will be a predictable period of nutritional stress. The most common nutritional problem is posed by the failure of sick children willingly to eat enough to maintain nutritional homeostasis. Supplementation of oral intake with a nutritional formula given by a small-bore nasogastric tube is simple, effective, and economical. If the sum of oral and tolerated nasogastric tube feedings is less than that required for optimal nutrition, unmet needs may be satisfied by nutrients given into a peripheral vein. Total parenteral nutrition, given by central vein, is reserved for situations in which the combination of enteral and peripheral venous alimentation is inadequate.

  3. Successful surgical treatment of left atrioesophageal fistula following atrial ablation.

    PubMed

    Takahashi, Toru; Mohara, Jun; Ogawa, Hiroomi; Igarashi, Takamichi; Motegi, Yoko

    2018-01-23

    A 69-year-old male had catheter-based ablation for atrial fibrillation. He was admitted with high fever and had neurological disorder; he was diagnosed with atrioesophageal fistula by CT scan. Intraoperative findings showed that the fistula existed adjacent to the left lower pulmonary vein with a vegetation. The esophageal fistula was repaired, and the left atrial fistula was closed. A nasogastric tube tip was placed in the esophagus for decompression and advanced into the stomach for nutritional support. After vomiting, the patient showed loss of consciousness and left hemiplegia. CT scan revealed a micro-air embolism to the brain. The nasogastric tube tip was pulled back into the esophagus. Gastrointestinal fiberscopy showed a pinhole at the fistula, and a percutaneous endoscopic gastrostomy was made. After conservative treatment, the esophageal fistula was closed and mediastinitis was improved. He was discharged with a little neurological deficit.

  4. A simple method for accurate endotracheal placement of an intubation tube in Guinea pigs to assess lung injury following chemical exposure.

    PubMed

    Nambiar, M P; Gordon, R K; Moran, T S; Richards, S M; Sciuto, A M

    2007-01-01

    ABSTRACT Guinea pigs are considered as the animal model of choice for toxicology and medical countermeasure studies against chemical warfare agents (CWAs) and toxic organophosphate pesticides because of the low levels of carboxylesterase compared to rats and mice. However, it is difficult to intubate guinea pigs without damaging the larynx to perform CWA inhalation experiments. We describe an easy technique of intubation of guinea pigs for accurate endotracheal placement of the intubation tube. The technique involves a speculum made by cutting the medium-size ear speculum in the midline leaving behind the intact circular connector to the otoscope. Guinea pigs were anesthetized with Telazol/meditomidine, the tongue was pulled using blunt forceps, and an otoscope attached with the specially prepared speculum was inserted gently. Insertion of the speculum raises the epiglottis and restrains the movements of vocal cord, which allows smooth insertion of the metal stylet-reinforced intubation tube. Accurate endotracheal placement of the intubation tube was achieved by measuring the length from the tracheal bifurcation to vocal cord and vocal cord to the upper front teeth. The average length of the trachea in guinea pigs (275 +/- 25 g) was 5.5 +/- 0.2 cm and the distance from the vocal cord to the front teeth was typically 3 cm. Coinciding an intubation tube marked at 6 cm with the upper front teeth accurately places the intubation tube 2.5 cm above the tracheal bifurcation. This simple method of intubation does not disturb the natural flora of the mouth and causes minimum laryngeal damage. It is rapid and reliable, and will be very valuable in inhalation exposure to chemical/biological warfare agents or toxic chemicals to assess respiratory toxicity and develop medical countermeasures.

  5. [Application of acupoint anatomy localization method with colorful tube in education of acupoint anatomy].

    PubMed

    Song, Shi-Lin

    2013-04-01

    To seek a precise and simple method for localization of acupoint in anatomical experiment teaching. Medical bone needles were inserted into acupoints. Then, self-mode copper probe needles were thrust along the center of the bone needles to open the inner structures of acuppoints. And probe needles were replaced by colored plastic tubes. Finally, bone needles were withdrawn so as to fix the plastic tubes into the acupoints to facilitate the later cutting. This method for acupoint anatomic positioning is of low cost with accurate positioning and simple manipulation, which has advantages in strong experimental and innovative values.

  6. YouTube as an educational tool regarding male urethral catheterization.

    PubMed

    Nason, Gregory J; Kelly, Padraig; Kelly, Michael E; Burke, Matthew J; Aslam, Asadullah; Giri, Subhasis K; Flood, Hugh D

    2015-04-01

    Urethral catheterization (UC) is a common procedure carried out on a daily basis. The aims of this study were to assess the quality of YouTube as an educational tool regarding male UC and to assess the experience of newly qualified doctors regarding UC. YouTube was searched for videos containing relevant information about male UC. A checklist for evaluating content for male UC was devised. The top-ranked video was shown to interns and they were questioned regarding their experience of UC and the usefulness of the video. A total of 100 videos was screened and 49 unique videos were identified. The median length of video was 7 min 15 s (range 1 min 44 s to 26 min 44 s). Regarding the Safe Catheter Insertion Score, the mean score was 5.18 ± 1.64. 9 (18.4%) deemed useful, 24 (49%) somewhat useful and 16 (32.7%) not useful. There was no difference in the number of views (p = 0.487), duration of video (p = 0.364) or number of days online (p = 0.123) between those categorized as useful, somewhat useful and not useful. Twenty-six interns (89.7%) attended the UC teaching session. All reported the video to be a useful educational adjunct. Nine of the respondents (42.9%) had independently inserted a urinary catheter before the educational session. The quality of videos on YouTube regarding male UC is widely variable. Preselected videos are deemed useful by junior doctors regarding male UC and can be used as an educational adjunct before performing hands-on tasks.

  7. A Cryogen Recycler with Pulse Tube Cryocooler for Recondensing Helium and Nitrogen

    NASA Astrophysics Data System (ADS)

    Wang, C.; Lichtenwalter, B.

    2015-12-01

    We have developed a cryogen recycler using a 4 K pulse tube cryocooler for recondensing helium and nitrogen in a NMR magnet. The liquid helium cooled NMR magnet has a liquid nitrogen cooled radiation shield. The magnet boils off 0.84 L/day of liquid helium and 6 L/day of liquid nitrogen. The recycler is designed with both a liquid helium return tube and a liquid nitrogen return tube, which are inserted into the fill ports of liquid helium and nitrogen. Therefore the recycler forms closed loops for helium and nitrogen. A two-stage 4 K pulse tube cryocooler, Cryomech model PT407 (0.7W at 4.2 K), is selected for the recycler. The recycler was first tested with a Cryomech's test cryostat and resulted in the capacities of recondensing 8.2 L/day of nitrogen and liquefying 4 L/day of helium from room temperature gas. The recycler has been installed in the NMR magnet at University of Sydney since August, 2014 and continuously maintains a zero boil off for helium and nitrogen.

  8. Fill-Tube-Induced Mass Perturbations on X-Ray-Driven, Ignition-Scale, Inertial-Confinement-Fusion Capsule Shells and the Implications for Ignition Experiments

    DOE PAGES

    Bennett, G. R.; Herrmann, M. C.; Edwards, M. J.; ...

    2007-11-13

    We present on the first inertial-confinement-fusion ignition facility, the target capsule will be DT filled through a long, narrow tube inserted into the shell. μg-scale shell perturbations Δm' arising from multiple, 10–50 μm-diameter, hollow SiO 2 tubes on x-ray-driven, ignition-scale, 1-mg capsules have been measured on a subignition device. Finally, simulations compare well with observation, whence it is corroborated that Δm' arises from early x-ray shadowing by the tube rather than tube mass coupling to the shell, and inferred that 10–20 μm tubes will negligibly affect fusion yield on a full-ignition facility.

  9. Experimental studies on laminar flow heat transfer in nanofluids flowing through a straight circular tube with and without V-cut twisted tape insert

    NASA Astrophysics Data System (ADS)

    Arunachalam, U.; Edwin, M.

    2018-03-01

    This paper presents experimental studies on the convective heat transfer and friction factor characteristics of flows in a straight circular tube with and without V-cut twisted tapeinserts using Al2O3-Cu/water hybrid nanofluid as working fluid and also comparative studies between Alumina nanofluid and (Cu-Alumina) hybrid nanofluid is conducted. This work is restricted to one type of hybrid nanofluid only. It also does not include the effect of twisted tape dimensions on heat transfer coefficient and pressure drop.Itis observed that the experimental convective heat transfer coefficient increases slightly with an increase in particle volume concentration from 0.1 and 0.4%. The experimental data is in good agreement with the previous models and correlations.The experimental results showed a good enhancement in Nusselt number for Peclet number from 2580 to 11,780 compared to Nusselt number of water, when the copper nanofluid is 0.01% volume concentration and mixed with 0.4% concentration of Alumina nanofluid.Itis also noticed that 0.01% Al2O3-Cu/water hybrid nanofluidhas a higher friction factor than the Al2O3/water nanofluid and base fluid. Since the magnitude of thermal enhancement factor (η) has been observed to be only marginally higher than unity (1.01 to 1.05), the net benefit of inserting V - cut twisted tapes in nanofluids is also nevertheless marginal.

  10. Turbine vane segment and impingement insert configuration for fail-safe impingement insert retention

    DOEpatents

    Burdgick, Steven Sebastian; Kellock, Iain Robertson

    2003-05-13

    An impingement insert sleeve is provided that is adapted to be disposed in a coolant cavity defined through a stator vane. The insert has a generally open inlet end and first and second pairs of diametrically opposed side walls, and at least one fail-safe tab defined at a longitudinal end of the insert for limiting radial displacement of the insert with respect to the stator vane.

  11. Tube pancreatico-duodenostomy for management of a severe penetrating pancreaticoduodenal injury.

    PubMed

    Hatzigeorgiadis, Anestis; Boulas, Konstantinos A; Barettas, Nikolaos; Papageorgiou, Irene; Blouhos, Konstantinos

    2014-05-27

    Optimal management of penetrating pancreaticoduodenal injuries and better outcomes are associated with simple, fast damage control surgery and shorter operative time. The performance of pyloric exclusion and tube duodenostomy has markedly decreased. However, there is still a trend toward their performance in cases of delay duodenal repair or severe pancreaticoduodenal injury. The present report describes a case of a hemodynamically stable patient with a single penetrating gunshot trauma causing an AAST-OIS grade III pancreatic head injury and grade IV injury of the second portion of the duodenum. The patient was treated in our Level IV rural trauma center and submitted to primary closure of the posterolateral duodenal wall (the laceration of the contralateral inner medial duodenal wall could not be repaired), external duodenal and pancreatic drainage, and duodenal decompression by tube pancreatico-duodenostomy (insertion of a 18 Fr Foley catheter through the laceration of the pancreatic head toward the duodenal lumen), tube cholangiostomy, and pyloric exclusion accompanied with a feeding jejunostomy. Tube pancreatico-duodenostomy, which is described for the first time in the literature, turned out to be effective and can be considered as an option in pancreaticoduodenal trauma when the inner medial duodenal wall cannot be repaired.

  12. Weight-for-height values and limb anthropometric composition of tube-fed children with quadriplegic cerebral palsy.

    PubMed

    Kong, Chi-Keung; Wong, Heung-Sang Stephen

    2005-12-01

    Research has shown that growth retardation among children with quadriplegic cerebral palsy (CP) is often attributed to feeding dysfunction and malnutrition. The study compared weight-for-height values and limb anthropometric composition of nasogastric and gastrostomy tube-fed children with quadriplegic CP with those of orally fed children with quadriplegic CP and normal children, to examine the plausible effects of tube feeding on weight-for-height, fat, and muscle values for children with quadriplegic CP. Triceps, anterior mid-thigh, and medial calf skinfold thicknesses and the corresponding circumferences of the right or less affected side were measured. The subjects consisted of 119 normal children and 62 orally fed and 48 tube-fed children with quadriplegic CP. Body weight and height were recorded. For children with CP whose height could not be measured, height was estimated from the ulna length. Weight-for-height z scores, limb skinfold thicknesses, fat areas, skinfold-corrected muscle girths, and muscle areas of the children were compared. Tube-fed children with CP had normal mean weight-for-height z scores. Weight-for-height z scores of the orally fed children with CP were significantly below those of normal children and tube-fed children with CP. For children with CP, whereas triceps skinfold thickness seemed to predict the mid-upper arm fat area correctly, leg skinfold thicknesses seemed to overestimate the corresponding fat areas. Stepwise multiple regression analysis showed that triceps skinfold thicknesses had good correlation (r = 0.86) and the presence of CP had nonsignificant correlation with mid-upper arm fat areas. Multiple regression analysis of fat areas with skinfold thicknesses and the presence of CP, however, showed that CP was correlated negatively (partial correlation of CP: thigh, -0.45; calf, -0.53) with thigh and calf fat areas. Although skinfold-corrected mid-upper arm muscle girths of children with CP were quite similar to those of

  13. Teleoperated master-slave needle insertion.

    PubMed

    Abolhassani, Niki; Patel, Rajni V

    2009-12-01

    Accuracy of needle tip placement and needle tracking in soft tissue are of particular importance in many medical procedures. In recent years, developing autonomous and teleoperated systems for needle insertion has become an active area of research. In this study, needle insertion was performed using a master-slave set-up with multi-degrees of freedom. The effect of force feedback on the accuracy of needle insertion was investigated. In addition, this study compared autonomous, teleoperated and semi-autonomous needle insertion. The results of this study show that incorporation of force feedback can improve teleoperated needle insertion. However, autonomous and semi-autonomous needle insertions, which use feedback from a deflection model, provide significantly better performance. Development of a haptic master-slave needle insertion system, which is capable of performing some autonomous tasks based on feedback from tissue deformation and needle deflection models, can improve the performance of autonomous robotics-based insertions as well as non-autonomous teleoperated manual insertions. Copyright (c) 2009 John Wiley & Sons, Ltd.

  14. Biocompatibility of “On-Command” Dissolvable Tympanostomy Tube in the Rat Model

    PubMed Central

    Mai, Johnny P.; Dumont, Matthieu; Rossi, Christopher; Cleary, Kevin; Wiedermann, Joshua; Reilly, Brian K.

    2016-01-01

    Objectives/Hypothesis A prototype tympanostomy tube, composed of (polybutyl/methyl methacrylate-co-dimethyl amino ethyl methacrylate (PBM)), was tested to (1) evaluate the effect of PBM tubes on rat dermis as a corollary for biocompatibility and (2) to observe the efficacy of dissolution with isopropyl alcohol (iPrOH) and ethanol (EtOH). Subjects and Methods A two-part study was conducted to assess biocompatible substance with inducible dissolvability as a critical characteristic for a newly engineered tympanostomy tube. First, tympanostomy tubes were inserted subcutaneously in 10 rats, which served as an animal model for biosafety and compared to traditional tubes with respect to histologic reaction. Tissue surrounding the PBM prototype tubes was submitted for histopathology and demonstrated no tissue reactivity or signs of major inflammation. In the second part, we evaluated the dissolvability of the tube with either isopropyl alcohol, ethanol, ofloxacin, ciprodex, water, and soapy water. PBM tubes were exposed to decreasing concentrations of iPrOH and EtOH with interval qualitative assessment of dissolution. Results (1) Histologic examination did not reveal pathology with PBM tubes; (2) Concentrations of at least 50% iPrOH and EtOH dissolve PBM tubes within 48 hours while concentrations of at least 75% iPrOH and EtOH were required for dissolution when exposure was limited to four 20-minute intervals. Conclusion PBM is biocompatible in the rat model. Additionally, PBM demonstrates rapid dissolution upon alcohol-based stimuli, validating the proof-of-concept of dissolvable “on-command” or biocommandible ear tubes. Further testing of PBM is needed with a less ototoxic dissolver and in a better simulated middle ear environment, before testing can be performed in humans. PMID:27796039

  15. Further Studies in Filmwise Condensation of Steam on Horizontal Finned Tubes

    DTIC Science & Technology

    1992-03-01

    which to base their design of Ocean Thermal Energy Conversion ( OTEC ) heat exchangers . ANL used two shell-and-tube heat exchangers , with no inserts, for...throughout the duration of this study. xiii~q I. INTRODUCTON A. BACKGROUND A reduction in size and weight of all types of heat exchangers aboard Naval...vessels will allow more efficient use of space. The benefits might include greater equipment accessibility for maintenance or greater heat exchanger

  16. Parameter predicting the recurrence of adhesive small bowel obstruction in patients managed with a long tube.

    PubMed

    Sakakibara, Takumi; Harada, Akio; Ishikawa, Tadao; Komatsu, Yoshinao; Yaguchi, Toyohisa; Kodera, Yasuhiro; Nakao, Akimasa

    2007-01-01

    Some of our patients showed a recurrence of adhesive small bowel obstruction (ASBO) with nonoperative management. The aim of this study was to evaluate the parameters predicting the recurrence of ASBO in patients managed with a long tube. Of 234 patients with ASBO admitted from April 1998 to September 2002, a total of 91 who recovered with nonoperative management after long tube placement were enrolled in this retrospective clinical study. We divided them into two groups for follow-up: the recurrence group and the no-recurrence group. We compared baseline characteristics, the number of previous ASBO admissions, the number of abdominal operations, the interval from the onset of symptoms to long-tube insertion, the duration of long-tube placement, the type of the contrasted intestine through the long tube, the location of the long-tube tip, and the drainage volume through the long tube between the two groups. We then examined the cumulative recurrence rate. A significant difference was found in the number of previous ASBO admissions, the duration of long-tube placement (77 hours vs. 43 hours), the contrasted intestine through the long tube, and the location of the long-tube tip. By multivariate analysis, the duration of long-tube placement was an independent parameter predicting the recurrence of ASBO. These results suggest that the duration of long-tube placement might serve as a parameter for predicting recurrence of ASBO in patients managed with a long tube.

  17. Do Financial Incentives of Introducing Case Mix Reimbursement Increase Feeding Tube Use in Nursing Home Residents?

    PubMed Central

    Teno, Joan M.; Feng, Zhanlian; Mitchell, Susan L.; Kuo, Sylvia; Intrator, Orna; Mor, Vincent

    2013-01-01

    OBJECTIVES To determine whether adoption of Medicaid case mix reimbursement is associated with greater prevalence of feeding tube use in nursing home (NH) residents. DESIGN Secondary analysis of longitudinal administrative data about the prevalence of feeding tube insertion and surveys of states’ adoption of case mix reimbursement. SETTING NHs in the United States. PARTICIPANTS NH residents at the time of NH inspection between 1993 and 2004. MEASUREMENTS Facility prevalence of feeding tubes reported at the state inspection of NHs reported in the Online Survey, Certification and Reporting database and interviews with state policy makers regarding the adoption of case mix reimbursement. RESULTS Between 1993 and 2004, 16 states adopted Resource Utilization Group case mix reimbursement. States varied in the prevalence of feeding tubes in their NHs. Although the use of feeding tube increased substantially over the years of the study, once temporal trends and facility fixed effects were accounted for, case mix reimbursement was not associated with greater prevalence of feeding tube use. CONCLUSION The adoption of Medicaid case mix reimbursement was not associated with an increase in the prevalence of feeding tube use. PMID:18331293

  18. Duodenal Loop Obstruction as an Unusual Cause of Acute Pancreatitis: A Case Series.

    PubMed

    Lee, Hyeonmin; Choi, Yonghyeok; Jeong, Hyewon; Lim, Jae Kyu; Jung, Taeyoung; Han, Joung Ho; Park, Seon Mee

    2016-12-25

    Duodenal loop obstruction is an unusual cause of acute pancreatitis. Increased intraluminal pressure hinders pancreatic flow, causing dilatation of the pancreatic duct and inducing acute pancreatitis. We experienced three cases of acute pancreatitis that resulted from duodenal loop obstruction after (1) an esophagectomy with gastric pull-up procedure for esophageal cancer, (2) a gastrectomy with Billroth I reconstruction for gastric cancer, and (3) a gastrojejunostomy for abdominal trauma. An abdominal CT scan revealed a distended duodenal loop, dilated pancreatic duct, and inflamed pancreas with fluid collection. Acute pancreatitis with duodenal loop obstruction was diagnosed by abdominal pain, elevated serum amylase/lipase, and abdominal CT findings. Immediate decompression with a nasogastric tube was performed, and all patients showed improvement within one week after admission. Each patient was followed up for more than two years without recurrence. Our findings suggest the usefulness of nasogastric tube decompression as the first line of treatment for acute pancreatitis related to duodenal loop obstruction.

  19. Preparation and characterization of spironolactone-loaded nano-emulsions for extemporaneous applications.

    PubMed

    Hallouard, François; Dollo, Gilles; Brandhonneur, Nolwenn; Grasset, Fabien; Corre, Pascal Le

    2015-01-15

    In neonates as well as in adults having swallowing difficulty, oral medication is given through a nasogastric tube making liquid formulations preferable. In this study, we present the high potential of nanometric emulsions formulated by spontaneous surfactant diffusion, as extemporaneous formulations of hydrophobic drug. Spironolactone used as hydrophobic drug model, was incorporated in oil before formulation at a concentration of 13.5mg/g oil. Then, all formulations were evaluated from pharmacotechnical and clinical standpoints, for their use in hospital or community pharmacy. The strength of this new liquid formulation lies on the simplicity, efficiency and reproducibility of their low energy process as on clinical aspects: high dose uniformity, facility to be administered through in nasogastric tube without any retention and a stability of 2 months at least compatible for an extemporaneous use. Moreover, this emulsion presented spironolactone content of 3.75 mg/ml among the most concentrated formulations published. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. The Direct Insertion of the ACL Carries More Load than the Indirect Insertion

    PubMed Central

    Nawabi, Danyal H.; Tucker, Scott; Jones, Kristofer J.; Nguyen, Joseph; Wickiewicz, Thomas L.; Imhauser, Carl; Pearle, Andrew

    2014-01-01

    Objectives: Recent histological studies have shown that the ACL consists of two different structures: the direct and indirect insertions. The direct insertion is located along the lateral intercondylar ridge and the indirect insertion is ‘lower’ in the notch, adjacent to the posterior articular cartilage. The ‘lower’ position has become more popular for locating the femoral tunnel, as surgeons switch to the anteromedial (AM) portal drilling technique in order to place the graft in the region of the native footprint. However, a recent registry-based outcomes study has reported a 1.5 times higher graft failure rate for AM portal versus traditional transtibial techniques. The objective of this study was to investigate the load characteristics of the native ACL in the regions of the direct and indirect insertions. We hypothesized that the direct insertion would carry more load than the indirect insertion. Methods: Twelve cadaveric knees were mounted to a six degree of freedom robot equipped with a universal force-moment sensor. We simulated the Lachman and anterior drawer tests at 30oand 90o of flexion by applying a 134N anterior load, and the pivot shift test at 15o flexion by applying combined valgus (8Nm) and internal (4Nm) rotational moments. The kinematic pathway required to achieve these loading conditions was recorded for each intact knee. Using position control to repeat the loading paths, the robot recorded the loads for the ACL intact, ACL partially sectioned, and ACL completely sectioned states. Sectioning Protocol: The lateral intercondylar ridge and posterior articular margin was identified in each case. The 50% mark between this two areas was used to delineate the regions of the direct and indirect insertions (Fig. 1). Sectioning order was alternated between each cadaver. Footprint Digitization: The borders of the sectioned areas were digitized post-sectioning and mapped onto a computed tomography (CT) scan of each knee. The sectioning method was

  1. Avulsed Nasoenteric Bridle System Magnet as an Intranasal Foreign Body.

    PubMed

    Puricelli, Michael D; Newberry, Christopher Ian; Gov-Ari, Eliav

    2016-02-01

    Nasoenteric tubes provide short-term nutrition support to patients unable to take an adequate oral diet. Bridling systems may be used to secure tubes to guard against displacement. We present the first case of an avulsed magnet from a bridling system to raise awareness of this potential complication. The primary methods of securing a nasogastric tube are reviewed, and comparative assessment of the 3 main systems is presented. Diagnosis and management of nasal foreign bodies relevant to this case are reviewed and prevention/safety considerations discussed. © 2015 American Society for Parenteral and Enteral Nutrition.

  2. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple's Operation.

    PubMed

    Bae, Sang Ho; Lee, Tae Hoon; Lee, Sae Hwan; Lee, Suck-Ho; Park, Sang-Heum; Kim, Sun-Joo; Kim, Chang Ho

    2011-05-01

    A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  3. Serial intracameral visualization of the Ahmed glaucoma valve tube by anterior segment optical coherence tomography.

    PubMed

    Lopilly Park, H-Y; Jung, K I; Park, C K

    2012-09-01

    To investigate serial changes of the Ahmed glaucoma valve (AGV) implant tube in the anterior chamber by anterior segment optical coherence tomography (AS-OCT). Patients who had received AGV implantation without complications (n=48) were included in this study. Each patient received follow-up examinations including AS-OCT at days 1 and 2, week 1, and months 1, 3, 6, and 12. Tube parameters were defined to measure its length and position. The intracameral length of the tube was from the tip of the bevel-edged tube to the sclerolimbal junction. The distance between the extremity of the tube and the anterior iris surface (T-I distance), and the angle between the tube and the posterior endothelial surface of the cornea (T-C angle) were defined. Factors that were related to tube parameters were analysed by multiple regression analysis. The mean change in tube length was -0.20 ± 0.17 mm, indicating that the tube length shortened from the initial inserted length. The mean T-I distance change was 0.11 ± 0.07 mm and the mean T-C angle change was -6.7 ± 5.6°. Uveitic glaucoma and glaucoma following penetrating keratoplasty showed the most changes in tube parameters. By multiple regression analysis, diagnosis of glaucoma including uveitic glaucoma (P=0.049) and glaucoma following penetrating keratoplasty (P=0.008) were related to the change of intracameral tube length. These results suggest that the length and position of the AGV tube changes after surgery. The change was prominent in uveitic glaucoma and glaucoma following penetrating keratoplasty.

  4. The Impact of Tympanostomy Tubes on Speech and Language Development in Children with Cleft Palate.

    PubMed

    Shaffer, Amber D; Ford, Matthew D; Choi, Sukgi S; Jabbour, Noel

    2017-09-01

    Objective Describe the impact of hearing loss, tympanostomy tube placement before palatoplasty, and number of tubes received on speech outcomes in children with cleft palate. Study Design Case series with chart review. Setting Tertiary care children's hospital. Subjects and Methods Records from 737 children born between April 2005 and April 2015 who underwent palatoplasty at a tertiary children's hospital were reviewed. Exclusion criteria were cleft repair at an outside hospital, intact secondary palate, absence of postpalatoplasty speech evaluation, sensorineural or mixed hearing loss, no tubes, first tubes after palatoplasty, or first clinic after 12 months of age. Data from 152 patients with isolated cleft palate and 166 patients with cleft lip and palate were analyzed using Wilcoxon rank-sum, χ 2 , and Fisher exact test and logistic regression. Results Most patients (242, 76.1%) received tubes before palatoplasty. Hearing loss after tubes, but not before, was associated with speech/language delays at 24 months ( P = .005) and language delays ( P = .048) and speech sound production disorders (SSPDs, P = .040) at 5 years. Receiving tubes before palatoplasty was associated with failed newborn hearing screen ( P = .001) and younger age at first posttubes type B tympanogram with normal canal volume ( P = .015). Hearing loss after tubes ( P = .021), language delays ( P = .025), SSPDs ( P = .003), and velopharyngeal insufficiency ( P = .032) at 5 years and speech surgery ( P = .022) were associated with more tubes. Conclusion Continued middle ear disease, reflected by hearing loss and multiple tubes, may impair speech and language development. Inserting tubes before palatoplasty did not mitigate these impairments better than later tube placement.

  5. Particles climbing along a vertically vibrating tube: numerical simulation using the Discrete Element Method (DEM)

    DOE PAGES

    Xu, Yupeng; Musser, Jordan; Li, Tingwen; ...

    2017-07-22

    It has been reported experimentally that granular particles can climb along a vertically vibrating tube partially inserted inside a granular silo. Here, we use the Discrete Element Method (DEM) available in the Multiphase Flow with Interphase eXchanges (MFIX) code to investigate this phenomenon. By tracking the movement of individual particles, the climbing mechanism was illustrated and analyzed. The numerical results show that a sufficiently high vibration strength is needed to form a low solids volume fraction region inside the lower end of the vibrating tube, a dense region in the middle of the tube, and to bring the particles outsidemore » from the top layers down to fill in the void. The results also show that particle compaction in the middle section of the tube is the main cause of the climbing. Consequently, varying parameters which influence the compacted region, such as the restitution coefficient, change the climbing height.« less

  6. Particles climbing along a vertically vibrating tube: numerical simulation using the Discrete Element Method (DEM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Yupeng; Musser, Jordan; Li, Tingwen

    It has been reported experimentally that granular particles can climb along a vertically vibrating tube partially inserted inside a granular silo. Here, we use the Discrete Element Method (DEM) available in the Multiphase Flow with Interphase eXchanges (MFIX) code to investigate this phenomenon. By tracking the movement of individual particles, the climbing mechanism was illustrated and analyzed. The numerical results show that a sufficiently high vibration strength is needed to form a low solids volume fraction region inside the lower end of the vibrating tube, a dense region in the middle of the tube, and to bring the particles outsidemore » from the top layers down to fill in the void. The results also show that particle compaction in the middle section of the tube is the main cause of the climbing. Consequently, varying parameters which influence the compacted region, such as the restitution coefficient, change the climbing height.« less

  7. Polychaete Tubes, Turbulence, and Erosion of Fine-Grained Sediment

    NASA Astrophysics Data System (ADS)

    Kincke-Tootle, A.; Frank, D. P.; Briggs, K. B.; Calantoni, J.

    2016-02-01

    The role of polychaete tubes protruding through the benthic boundary layer in promoting or hindering erosion of fine-grained sediment was examined in laboratory experiments. Diver core samples of the top 10cm of sediment were collected west of Trinity Shoal off the Louisiana coast in 10-m depth. Diver cores were used in laboratory experiments conducted in a unidirectional flume. Tubes that were constructed by polychaetes, which comprised 70% of the species from the study area, were inserted into the core sediment surface. The sediment cores were then placed in the 2-m long test section of a small oscillatory flow tunnel and high-speed, stereo particle image velocimetry was used to determine the 2-dimensional, 3-component fluid velocity at high temporal (100 Hz) and spatial (< 1mm vector spacing) resolution. The tubes that protruded above the boundary layer allowed vortices to be initiated. Tubes are made up of shell fragments and fine-grained sediment, allowing for some rigidity and resistance to the flow. Rigidity determines the resistance causing small-scale eddies to form. The small-scale turbulence incited scour erosion, allowing fine-grained particles to be suspended into the water and in some cases coarser particles to be mobilized. Less-rigid tubes succumb to the shear stress, inhibit the formation of small-scale eddies, limit sediment erodibility, and increase the critical shear stress of the sediment. Discussion will focus on a modification to the critical Shields parameter to account for the effects of benthic biological activity.

  8. Qualification of oil-based tracer particles for heated Ludwieg tubes

    NASA Astrophysics Data System (ADS)

    Casper, Marcus; Stephan, Sören; Scholz, Peter; Radespiel, Rolf

    2014-06-01

    The generation, insertion, pressurization and use of oil-based tracer particles is qualified for the application in heated flow facilities, typically hypersonic facilities such as Ludwieg tubes. The operative challenges are to ensure a sub-critical amount of seeding material in the heated part, to qualify the methods that are used to generate the seeding, pressurize it to storage tube pressure, as well as to test specific oil types. The mass of the seeding material is held below the lower explosion limit such that operation is safe. The basis for the tracers is qualified in off-situ particle size measurements. In the main part different methods and operational procedures are tested with respect to their ability to generate a suitable amount of seeding in the test section. For the best method the relaxation time of the tracers is qualified by the oblique shock wave test. The results show that the use of a special temperature resistant lubricant oil "Plantfluid" is feasible under the conditions of a Mach-6 Ludwieg tube with heated storage tube. The method gives high-quality tracers with high seeding densities. Although the experimental results of the oblique shock wave test differ from theoretical predictions of relaxation time, still the relaxation time of 3.2 μs under the more dense tunnel conditions with 18 bar storage tube pressure is low enough to allow the use of the seeding for meaningful particle image velocimetry studies.

  9. Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study.

    PubMed

    Castle, Nick; Owen, Robert; Hann, Mark; Naidoo, Raveen; Reeves, David

    2010-11-01

    Control of the airway is a priority during cardiopulmonary resuscitation and/or following a failed intubation attempt. Supraglottic airway devices provide more effective airway management than bag-valve-mask-ventilation (BVMV) and can be effectively used by non-anaesthetists. 36 paramedic students were timed to ascertain how long it took them to place an Igel, laryngeal mask airway (LMA) or laryngeal tube airway (LTA) into a manikin. Following insertion, students were interviewed to see which device they preferred and why. The Igel was consistently the fastest airway device, taking a mean of 12.3 s (95% CI 11.5 to 13.1) to insert, the LTA took a mean time of 22.4 s (95% CI 20.3 to 24.5) and the LMA 33.8 s (95% CI 30.9 to 36.7). 63% of students would choose the Igel as their preferred intermediate airway device, stating ease of use and speed of insertion as the primary reasons. The ease and speed at which a supraglottic airway can be inserted means that it is a viable alternative to the use of the BVMV.

  10. [Use of the air-Q laryngeal airway and tube exchanger in a case of difficult tracheal extubation after maxillectomy].

    PubMed

    Komasawa, Nobuyasu; Ueki, Ryusuke; Iwasaki, Yohei; Tatara, Tsuneo; Tashiro, Chikara; Kaminoh, Yoshiroh

    2012-10-01

    A 79-year-old man was diagnosed with maxillary cancer and underwent total maxillectomy under general anesthesia. The oropharyngeal airway was needed for efficient mask ventilation during anesthesia induction. The maxilla was totally resected and reconstructed with skin from a femoral flap. Tracheal extubation was considered to be difficult given that mask ventilation was contraindicated due to reconstruction of the maxilla. After inserting a tube exchanger (TE) into the trachea, the tracheal tube was exchanged with an air-Q laryngeal airway through the TE. After confirming effective ventilation with the air-Q mask, the patient was awakened from anesthesia. We confirmed sufficient spontaneous breathing and no active bleeding in the pharynx. After re-inserting the TE thorough air-Q, the air-Q was removed, followed by removal of the TE. These findings suggest that the air-Q and TE were effective in a case of difficult extubation after maxillectomy.

  11. Protective tubes for sodium heated water tubes

    DOEpatents

    Essebaggers, Jan

    1979-01-01

    A heat exchanger in which water tubes are heated by liquid sodium which minimizes the results of accidental contact between the water and the sodium caused by failure of one or more of the water tubes. A cylindrical protective tube envelopes each water tube and the sodium flows axially in the annular spaces between the protective tubes and the water tubes.

  12. Risk factors and molecular epidemiology of extended-spectrum β-lactamase-producing Klebsiella pneumoniae in Xiamen, China.

    PubMed

    Deng, Jie; Li, Yan-Ting; Shen, Xu; Yu, Yi-Wen; Lin, Hui-Ling; Zhao, Qi-Feng; Yang, Tian-Ci; Li, Shu-Lian; Niu, Jian-Jun

    2017-12-01

    The aim of this study was to evaluate the risk factors for pneumonia due to extended-spectrum β-lactamase-producing Klebsiella pneumoniae (ESBL-KP) and to analyse the molecular epidemiology of ESBL-KP in Xiamen, China. A case-control study was conducted at Zhongshan Hospital from January 2014 to August 2015. Medical records of patients with nosocomial pneumonia caused by K. pneumoniae were collected. A total of 40 cases with ESBL-KP infection and 90 controls with non-ESBL-KP infection were included. The sequence types (STs) of the 40 ESBL-KP strains were determined by multilocus sequence typing (MLST). Univariate analysis primarily revealed an association between the following seven risk factors and ESBL-KP infection (P<0.10): length of hospitalisation; use of cephalosporins; use of quinolones; presence of a nasogastric tube; presence of an intravenous catheter; mechanical ventilation; and cerebrospinal fluid drainage. Furthermore, multivariate analysis revealed that use of cephalosporins and presence of a nasogastric tube were independent risk factors for ESBL-KP infection (P<0.05), with adjusted odds ratios of 3.473 [95% confidence interval (CI) 1.105-10.911; P=0.033] and 2.488 (95% CI 1.083-5.715; P=0.032), respectively. MLST identified 28 STs. The main STs were ST23 (10.0%) and ST37 (10.0%); three novel STs were identified. Use of cephalosporins and presence of a nasogastric tube are independent risk factors for ESBL-KP infection. In addition, the discovery of three novel STs serves as a reminder to continuously monitor outbreaks of ESBL-KP infection. Copyright © 2017. Published by Elsevier Ltd.

  13. Pharmacokinetic Profiles of Ticagrelor Orodispersible Tablets in Healthy Western and Japanese Subjects.

    PubMed

    Teng, Renli; Hammarberg, Maria; Carlson, Glenn F; Bokelund-Singh, Sara; Ruderfelt, Terese; Blychert, Eva

    2017-11-01

    Ticagrelor is an antiplatelet agent for patients with acute coronary syndrome or a history of myocardial infarction. Two studies compared pharmacokinetic profiles of orodispersible (OD) ticagrelor tablets versus immediate-release (IR) tablets in Western and Japanese subjects. Both studies were open-label, randomized, crossover, single-center trials. Thirty-six healthy subjects (94% white, 6% other race; Western study NCT02400333) and 42 Japanese healthy subjects (Japanese study NCT02436577) received a single 90-mg ticagrelor dose as an OD tablet [with/without water, and via a nasogastric tube (Western study only)], and an IR tablet; washout between treatments was ≥7 days. Assessments included ticagrelor and AR-C124910XX (active metabolite) plasma concentrations for pharmacokinetic analyses, and safety evaluations. In the Western study, the 90% confidence intervals (CIs) of the geometric mean ratios (GMRs) for ticagrelor and AR-C124910XX maximum plasma concentration (C max ) and area under the plasma concentration-time curve (AUC) were within the acceptance interval (80%-125%) for OD tablets (with/without water, via a nasogastric tube) versus the IR tablet; except for an ~15% lowering of ticagrelor C max (90% CI: 76.77%-93.78%) for the OD tablet taken with water. In the Japanese study, 90% CIs of the GMRs for AUC and C max of both ticagrelor and AR-C124910XX were all within the acceptance intervals for the OD (with/without water) versus IR tablet. No new safety issues were identified. Ticagrelor administered as an OD tablet to Western (without water, and via a nasogastric tube) and Japanese (with/without water) subjects was bioequivalent to the IR tablet.

  14. Bioequivalence among three methods of administering pantoprazole granules in healthy subjects.

    PubMed

    Tammara, Brinda; Weisel, Kathy; Katz, Arie; Meng, Xu

    2009-11-01

    The bioequivalence among three methods of administering pantoprazole granules was studied in healthy subjects. In this randomized, open-label, three-period, crossover study, 25 healthy adults received a single 40-mg dose of pantoprazole granules with applesauce orally, with apple juice orally, and with apple juice administered via a nasogastric tube. Subjects were randomly assigned to one of six treatment sequences. Blood samples were collected within 2 hours before treatment administration on study day 1 and at 0.33, 0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, and 24 hours after treatment administration. Plasma pantoprazole concentrations were analyzed by a validated liquid chromatography-tandem mass spectrometry method. The plasma pantoprazole concentration-time data for each subject were analyzed using noncompartmental methods. The 90% confidence intervals (CIs) for the test:reference geometric mean ratio were calculated for the peak pantoprazole concentration (C(max) ) and area under the concentration-time curve (AUC). Of the 25 subjects enrolled, 100% completed the study. The mean C(max) and AUC values were similar for the three administration methods. The 90% CIs for the ratios of the geometric means of the granules in apple juice orally (92.4-112.5%) and in apple juice administered through a nasogastric tube (102.7-125.2%), relative to the granules administered with applesauce orally, were essentially within the bioequivalent limits of 80-125%. No serious adverse events or study discontinuations occurred. Three methods of administering pantoprazole delayed-release granules for oral suspension-with apple juice orally, with applesauce orally, and with apple juice through a nasogastric tube--were bioequivalent in healthy subjects.

  15. The NASA, Marshall Space Flight Center drop tube user's manual

    NASA Technical Reports Server (NTRS)

    Rathz, Thomas J.; Robinson, Michael B.

    1990-01-01

    A comprehensive description of the structural and instrumentation hardware and the experimental capabilities of the 105-meter Marshall Space Flight Center Drop Tube Facility is given. This document is to serve as a guide to the investigator who wishes to perform materials processing experiments in the Drop Tube. Particular attention is given to the Tube's hardware to which an investigator must interface to perform experiments. This hardware consists of the permanent structural hardware (with such items as vacuum flanges), and the experimental hardware (with the furnaces and the sample insertion devices). Two furnaces, an electron-beam and an electromagnetic levitator, are currently used to melt metallic samples in a process environment that can range from 10(exp -6) Torr to 1 atmosphere. Details of these furnaces, the processing environment gases/vacuum, the electrical power, and data acquisition capabilities are specified to allow an investigator to design his/her experiment to maximize successful results and to reduce experimental setup time on the Tube. Various devices used to catch samples while inflicting minimum damage and to enhance turnaround time between experiments are described. Enough information is provided to allow an investigator who wishes to build his/her own furnace or sample catch devices to easily interface it to the Tube. The experimental instrumentation and data acquisition systems used to perform pre-drop and in-flight measurements of the melting and solidification process are also detailed. Typical experimental results are presented as an indicator of the type of data that is provided by the Drop Tube Facility. A summary bibliography of past Drop Tube experiments is provided, and an appendix explaining the noncontact temperature determination of free-falling drops is provided. This document is to be revised occasionally as improvements to the Facility are made and as the summary bibliography grows.

  16. MARTINS: A foam/film flow model for molten material relocation in HWRs with U-Al-fueled multi-tube assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalimullah

    1994-03-01

    Some special purpose heavy-water reactors (EM) are made of assemblies consisting of a number of coaxial aluminum-clad U-Al alloy fuel tubes and an outer Al sleeve surrounding the fuel tubes. The heavy water coolant flows in the annular gaps between the circular tubes. Analysis of severe accidents in such reactors requires a model for predicting the behavior of the fuel tubes as they melt and disrupt. This paper describes a detailed, mechanistic model for fuel tube heatup, melting, freezing, and molten material relocation, called MARTINS (Melting and Relocation of Tubes in Nuclear subassembly). The paper presents the modeling of themore » phenomena in MARTINS, and an application of the model to analysis of a reactivity insertion accident. Some models are being developed to compute gradual downward relocation of molten material at decay-heat power levels via candling along intact tubes, neglecting coolant vapor hydrodynamic forces on molten material. These models are inadequate for high power accident sequences involving significant hydrodynamic forces. These forces are included in MARTINS.« less

  17. Transfer of a cold atmospheric pressure plasma jet through a long flexible plastic tube

    NASA Astrophysics Data System (ADS)

    Kostov, Konstantin G.; Machida, Munemasa; Prysiazhnyi, Vadym; Honda, Roberto Y.

    2015-04-01

    This work proposes an experimental configuration for the generation of a cold atmospheric pressure plasma jet at the downstream end of a long flexible plastic tube. The device consists of a cylindrical dielectric chamber where an insulated metal rod that serves as high-voltage electrode is inserted. The chamber is connected to a long (up to 4 m) commercial flexible plastic tube, equipped with a thin floating Cu wire. The wire penetrates a few mm inside the discharge chamber, passes freely (with no special support) along the plastic tube and terminates a few millimeters before the tube end. The system is flushed with Ar and the dielectric barrier discharge (DBD) is ignited inside the dielectric chamber by a low frequency ac power supply. The gas flow is guided by the plastic tube while the metal wire, when in contact with the plasma inside the DBD reactor, acquires plasma potential. There is no discharge inside the plastic tube, however an Ar plasma jet can be extracted from the downstream tube end. The jet obtained by this method is cold enough to be put in direct contact with human skin without an electric shock. Therefore, by using this approach an Ar plasma jet can be generated at the tip of a long plastic tube far from the high-voltage discharge region, which provides the safe operation conditions and device flexibility required for medical treatment.

  18. Phenotypic characterization of an Arabidopsis T-DNA insertion line SALK_063500.

    PubMed

    Sng, Natasha J; Paul, Anna-Lisa; Ferl, Robert J

    2018-06-01

    In this article we report the identification of a homozygous lethal T-DNA (transfer DNA) line within the coding region of the At1G05290 gene in the genome of Arabidopsis thaliana (Arabidopsis) line, SALK_063500. The T-DNA insertion is found within exon one of the AT1G05290 gene, however a homozygous T-DNA allele is unattainable. In the heterozygous T-DNA allele the expression levels of AT1G05290 were compared to wild type Arabidopsis (Col-0, Columbia). Further analyses revealed an aberrant silique phenotype found in the heterozygous SALK_063500 plants that is attributed to the reduced rate of pollen tube germination. These data are original and have not been published elsewhere.

  19. Steroid Versus Antibiotic Drops in the Prevention of Postoperative Myringotomy Tube Complications.

    PubMed

    Alvi, Sameer A; Jones, Joel W; Porter, Paul; Perryman, Mollie; Nelson, Karen; Francis, Carrie L; Larsen, Christopher G

    2018-07-01

    To determine the incidence of early postoperative tympanostomy tube insertion otorrhea and obstruction in pediatric patients receiving antibiotic ear drops with or without steroid perioperatively. A retrospective chart review was performed on patients who underwent outpatient myringotomy and tube placement. Patients from June 2013 to February 2014 received ciprofloxacin/dexamethasone perioperatively while patients from May 2014 to April 2015 received ofloxacin. Statistical analysis was performed to compare outcomes between the cohorts. One hundred thirty-four patients received topical ciprofloxacin/dexamethasone, and 116 patients received topical ofloxacin. The rate of postoperative otorrhea was 5.2% for the ciprofloxacin/dexamethasone group and 8.2% for the ofloxacin group. Tube obstruction was seen in 6.0% of the ciprofloxacin/dexamethasone group and 5.2% in the ofloxacin group. Neither outcome had a statistically significant difference ( P = .21 and .85, respectively). There was no difference in the rate of effusion at the time of tube placement between the 2 cohorts ( P = .16), and this included subgroup analysis based on effusion type (mucoid, purulent, serous). Patients with a mucoid effusion at the time of surgery were more likely to experience otorrhea/obstruction than patients with dry ears (odds ratio = 2.23, P = .02). No significant difference in the incidence of immediate postoperative tympanostomy tube otorrhea or obstruction was seen between the antibiotic-steroid and antibiotic alone cohorts, regardless of effusion type. Overall, patients with mucoid effusions are more likely to develop tube otorrhea or obstruction at follow-up. Cost-effective drops should be used when prescribing topical therapy to prevent complications after ear tubes.

  20. Tool Removes Coil-Spring Thread Inserts

    NASA Technical Reports Server (NTRS)

    Collins, Gerald J., Jr.; Swenson, Gary J.; Mcclellan, J. Scott

    1991-01-01

    Tool removes coil-spring thread inserts from threaded holes. Threads into hole, pries insert loose, grips insert, then pulls insert to thread it out of hole. Effects essentially reverse of insertion process to ease removal and avoid further damage to threaded inner surface of hole.

  1. Endoscopic placement of Jones lacrimal tubes with the assistance of holmium YAG laser.

    PubMed

    Boboridis, Kostas G; Downes, Richard N

    2005-06-01

    The aim of this paper is to highlight the use of the Holmium YAG laser in the endoscopic placement of Lester Jones tubes in patients with a blocked canaliculus or failed lacrimal pump function. Sixteen cases with a non-functional canaliculus were included over a one-year period. Following caruncle excision, a 19 G needle is inserted through the medial canthal tissues into the nasal space. Nasal endoscopy confirms the accurate positioning in relation to the nasal anatomy. With the Holmium YAG laser, a tissue channel is fashioned around the guide needle through the structures of the lateral nasal wall to facilitate an accurate and secure placement of the Jones tube. The endoscopic, laser-assisted placement reduces the operating time to less than 20 minutes, minimizes tissue trauma and does not require the initial surgical steps of an open DCR procedure. There were 14 cases (87.5%) with securely retained tubes and two cases (12.5%) that required tube replacement. The advantage of the procedure is especially great in revision surgery where the ostium is opened through scar tissue. Nasal endoscopy with the assistance of the Holmium YAG laser offers simplicity and precision in the placement of Jones tubes. It minimizes tissue trauma and increases the surgical success rate.

  2. The use of IV-tubing as a closed-suction drainage system during neurosurgical cases in Tanzania.

    PubMed

    Bonfield, Christopher M; Shabani, Hamisi K; Kanumba, Emmanuel S; Ellegala, Dilantha B; Nicholas, Joyce

    2013-01-01

    Commercial closed-suctions drainage systems are commonly used in the United States and many other countries for use in neurosurgical cases. However, in Tanzania and other developing nations with fewer resources, these are not available. This report explores another option for a closed-system drainage system utilizing inexpensive supplies found commonly in hospitals around the world. Sterile IV-tubing is cut, inserted into the wound, and brought out through an adjacent puncture incision. For suction, an empty plastic bottle can be attached to the tubing. The IV-tubing closed-suction drainage system was applied in both cranial and spinal neurosurgical procedures, including as subdural, subgaleal, epidural, and suprafacial drains. It maintained suction and was an adequate substitute when commercial drains are unavailable. This report illustrates how sterile IV-tubing can be adapted for use as a closed-drainage system. It utilizes inexpensive supplies commonly found in many hospitals throughout the world and can be applied to both cranial and spinal neurosurgical procedures.

  3. New analytical spiral tube assembly for separation of proteins by counter-current chromatography.

    PubMed

    Ma, Xiaofeng; Ito, Yoichiro

    2015-07-31

    A new spiral column assembly for analytical separation by counter-current chromatography is described. The column is made from a plastic spiral tube support which has 12 interwoven spiral grooves. The PTFE tubing of 1.6mm ID was first flattened by extruding through a narrow slit and inserted into the grooves to make 5 spiral layers with about 60ml capacity. The performance of the spiral column assembly was tested with separation of three stable protein samples including cytochrome C, myoglobin and lysozyme in a polymer phase system composed of polyethylene glycol 1000 and dibasic potassium phosphate each at 12.5% (w/w) in water. At 2ml/min, three protein samples were well resolved in 1h. The separation time may be further shortened by application of higher revolution speed and flow rate by improving the strength of the spiral tube support in the future. Published by Elsevier B.V.

  4. Feeding tube insertion - gastrostomy

    MedlinePlus

    ... and the A.D.A.M. Editorial team. Nutritional Support Read more NIH MedlinePlus Magazine Read more ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should ...

  5. Insertion device and method for accurate and repeatable target insertion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  6. Sterilization of Long Tube Inner Surface Using Oxygen and Water Vapor Plasmas Produced by AC HV Discharge

    NASA Astrophysics Data System (ADS)

    Kitazaki, Satoshi; Hayashi, Nobuya

    2009-10-01

    Oxygen and water vapor plasmas inside a narrow long tube were produced using an AC HV glow discharge at low pressure in order to sterilize the inner surface of a tube. In order to produce plasma inside a narrow tube, an AC high voltage was adopted. The material of the tube used in this experiment was silicon rubber. The length and diameter of the tubes ranged from 300 to 1,000 mm and from 1 to 4 mm, respectively. The tube was placed in a stainless steel vacuum chamber and was evacuated to 10 Pa using a rotary pump. The material gas for plasma and radical productions was pure oxygen or water vapor, which was introduced to the chamber from a gas cylinder or water reservoir. Light emission spectral lines of oxygen and OH radicals were observed at 777 nm and 306 nm, respectively. The chemical indicator was inserted into the tube and turned to a yellowish color (from the original red) after a treatment, which indicates the generation of sufficient oxygen on OH radicals for sterilization. A tube with the length of 500 mm and diameter of 4 mm is sterilized using oxygen plasma by 10 minutes treatment. Also a tube with the length of 300 mm and diameter of 2 mm is sterilized using water vapor plasma by 5 minutes treatment.

  7. An experimental investigation on heat transfer enhancement in the laminar flow of water/TiO2 nanofluid through a tube heat exchanger fitted with modified butterfly inserts

    NASA Astrophysics Data System (ADS)

    Venkitaraj, K. P.; Suresh, S.; Alwin Mathew, T.; Bibin, B. S.; Abraham, Jisa

    2018-03-01

    Nanofluids are advanced heat transfer fluids that exhibit thermal properties superior than that of the conventional fluids such as water, oil etc. This paper reports the experimental study on convective heat transfer characteristics of water based titanium dioxide nanofluids in fully developed flow through a uniformly heated pipe heat exchanger fitted with modified butterfly inserts. Nanofluids are prepared by dispersing TiO2 nanoparticles of average particle size 29 nm in deionized water. The heat transfer experiments are performed in laminar regime using nanofluids prepared with 0.1% and 0.3% volume fractions of TiO2 nanoparticles. The thermal performance characteristics of conventional butterfly inserts and modified butterfly inserts are also compared using TiO2 nanofluid. The inserts with different pitches 6 cm, 9 cm and 12 cm are tested to determine the effect of pitch distance of inserts in the heat transfer and friction. The experimental results showed that the modification made in the butterfly inserts were able to produce higher heat transfer than conventional butterfly inserts.

  8. Software-implemented fault insertion: An FTMP example

    NASA Technical Reports Server (NTRS)

    Czeck, Edward W.; Siewiorek, Daniel P.; Segall, Zary Z.

    1987-01-01

    This report presents a model for fault insertion through software; describes its implementation on a fault-tolerant computer, FTMP; presents a summary of fault detection, identification, and reconfiguration data collected with software-implemented fault insertion; and compares the results to hardware fault insertion data. Experimental results show detection time to be a function of time of insertion and system workload. For the fault detection time, there is no correlation between software-inserted faults and hardware-inserted faults; this is because hardware-inserted faults must manifest as errors before detection, whereas software-inserted faults immediately exercise the error detection mechanisms. In summary, the software-implemented fault insertion is able to be used as an evaluation technique for the fault-handling capabilities of a system in fault detection, identification and recovery. Although the software-inserted faults do not map directly to hardware-inserted faults, experiments show software-implemented fault insertion is capable of emulating hardware fault insertion, with greater ease and automation.

  9. Hannah's Feeding Journey: A Multidisciplinary Treatment Approach to Establishing Oral Acceptance for a Toddler with a Complex Medical History

    ERIC Educational Resources Information Center

    Dunn, Dena M.; Galbally, Sandra Lynn; Markowitz, Goldie; Pucci, Kristy N.; Brochi, Ligia; Cohen, Sherri Shubin

    2017-01-01

    This article presents the importance of multidisciplinary, family-centered care, and a developmental bio-psycho-social approach to treating feeding difficulties in a child with a complex medical history. Hannah spent the first 9 months of her life in the hospital and was discharged dependent on nasogastric tube feeding. Her journey to recovery…

  10. Consideration of alternative designs for a Percutaneous Endoscopic Gastrostomy feeding tube

    NASA Astrophysics Data System (ADS)

    Yerrabolu, Santosh Rohit

    The inability of some people to chew or swallow foods (but can digest foods) due to problems associated with various diseases and complications leads them to insufficient nutritional intake and loss of quality of life. These individuals are generally provided with nutritional support by means of injecting or infusing food directly into their stomachs or small intestines via feeding tubes. Gastrostomy feeding tubes (G-tubes) are used when such nutritional support is required for over 3-6 weeks. Percutaneous Endoscopic Gastrostomy (PEG) tubes are one of the most widely used G- Tubes and devices which are inserted via an incision through the abdominal wall either through a pull or push method. This investigation proposes conceptual alternative Percutaneous Endoscopy Gastrostomy (PEG) feeding tube designs with optimized materials selection to be used for their construction. The candidate materials were chosen from 18 commercial catheters, 2 reference grade polymers and a commercial polymer; using tissue-catheter-friction testing and surface chemistry characterization (Infrared spectroscopy and Critical Surface Tension approximation). The main objectives considered were to minimize slipping/dislodgement of gastrostomy tube/seal, to reduce peristomal leakage, and to attain size variability of PEG tubes while maintaining a low profile. Scanning Electron Microscope- Energy Dispersive X-ray Spectroscopy was employed to further determine the filler materials used in the samples. Nylon coated with fatty ester and filled with Barium sulphate was determined as the optimum material for the construction of the tube part of the feeding tubes to reduce slipping/dislodgment of gastrostomy tube/seal and to minimize peristomal leakage. Nylon coated with fatty ester and filled with Silica is the suggested as a candidate material for construction of the bumper/mushroom sections of the feeding tubes to avoid the Buried Bumper Syndrome. Fused Deposition Modeling, Selective Laser Sintering

  11. Scedosporium apiospermum causing otomycosis in an immunocompetent child with tympanostomy tubes: Management of this rare entity.

    PubMed

    Salamat, A A; Archer, C; Basarab, A; Eren, E; Batty, V; Patel, S; Salib, R J; Burgess, A; Ismail-Koch, H

    2015-10-01

    Infection following a tympanostomy tube insertion is a common occurrence. Scedosporium apiospermum is a filamentous fungus mainly isolated in water and soil. There have been no reported cases of S. apiospermum infection of an immunocompetent individual with a tympanostomy tube in situ. A child was referred with unilateral otorrhoea failing to respond to conventional treatment in the community. S. apiospermum was identified following specialist testing. An extended course of anti-fungal treatment led to complete resolution. Due to the rare occurrence of aural S. apiospermum and unreported nature, it should be managed in a multidisciplinary setting. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Calcium-dependent protein kinases regulate polarized tip growth in pollen tubes.

    PubMed

    Myers, Candace; Romanowsky, Shawn M; Barron, Yoshimi D; Garg, Shilpi; Azuse, Corinn L; Curran, Amy; Davis, Ryan M; Hatton, Jasmine; Harmon, Alice C; Harper, Jeffrey F

    2009-08-01

    Calcium signals are critical for the regulation of polarized growth in many eukaryotic cells, including pollen tubes and neurons. In plants, the regulatory pathways that code and decode Ca(2+) signals are poorly understood. In Arabidopsis thaliana, genetic evidence presented here indicates that pollen tube tip growth involves the redundant activity of two Ca(2+)-dependent protein kinases (CPKs), isoforms CPK17 and -34. Both isoforms appear to target to the plasma membrane, as shown by imaging of CPK17-yellow fluorescent protein (YFP) and CPK34-YFP in growing pollen tubes. Segregation analyses from two independent sets of T-DNA insertion mutants indicate that a double disruption of CPK17 and -34 results in an approximately 350-fold reduction in pollen transmission efficiency. The near sterile phenotype of homozygous double mutants could be rescued through pollen expression of a CPK34-YFP fusion. In contrast, a transgene rescue was blocked by mutations engineered to disrupt the Ca(2+)-activation mechanism of CPK34 (CPK34-YFP-E465A,E500A), providing in vivo evidence linking Ca(2+) activation to a biological function of a CPK. While double mutant pollen tubes displayed normal morphology, relative growth rates for the most rapidly growing tubes were reduced by more than three-fold compared with wild type. In addition, while most mutant tubes appeared to grow far enough to reach ovules, the vast majority (>90%) still failed to locate and fertilize ovules. Together, these results provide genetic evidence that CPKs are essential to pollen fitness, and support a mechanistic model in which CPK17 and -34 transduce Ca(2+) signals to increase the rate of pollen tube tip growth and facilitate a response to tropism cues.

  13. Tube support

    DOEpatents

    Mullinax, Jerry L.

    1988-01-01

    A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.

  14. Tapered pulse tube for pulse tube refrigerators

    DOEpatents

    Swift, Gregory W.; Olson, Jeffrey R.

    1999-01-01

    Thermal insulation of the pulse tube in a pulse-tube refrigerator is maintained by optimally varying the radius of the pulse tube to suppress convective heat loss from mass flux streaming in the pulse tube. A simple cone with an optimum taper angle will often provide sufficient improvement. Alternatively, the pulse tube radius r as a function of axial position x can be shaped with r(x) such that streaming is optimally suppressed at each x.

  15. TUBE TESTER

    DOEpatents

    Gittings, H.T. Jr.; Kalbach, J.F.

    1958-01-14

    This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.

  16. Effect of Intraoral Aging on Debris Accumulation and Friction of First Molar Tubes.

    PubMed

    Chaptini, Edmond; Khoury, Elie; Cacciafesta, Vittorio; Naaman, Nada

    2016-11-01

    The aim of this article was to evaluate the impact of intraoral aging and site specificity on debris accumulation and friction in molar tubes after intraoral use. A total of 80 intraorally used first molar convertible tubes were provided by 20 orthodontic adolescent patients after 6 months of treatment. The specimens were divided into eight groups (n = 10) according to the mouth quadrant and the type of examination [four groups of ten tubes for scanning electron microscope (SEM) and four groups of ten tubes for friction test]. Scanning electron microscope examination was performed after opening the convertible caps and friction test was executed using a 0.019'' × 0.025'' stainless steel wire, which was inserted in the tubes belonging to each group. The Mann-Whitney test, analysis of variance (ANOVA), and Bonferroni tests were performed for statistical analysis at 0.01 level of significance. There was a significant increase in the amount of debris and frictional force after 6 months of intraoral exposure (p < 0.0001). Debris scores were higher (10% increase) on the upper tubes when compared with the lower ones, with no statistical difference. Mean frictional force ranged from 0.22 to 0.26 N according to the mouth quadrant, but the difference between groups was also not significant. After 6 months of intraoral exposure, there was a significant increase in the amount of debris in the first molar tube slots, leading to significantly higher frictional forces during sliding mechanics. The influence of site specificity on the amount of debris and on frictional forces of the first molar tubes could not be demonstrated. Molar tubes should be cleaned, before and during sliding mechanics, in order to minimize friction.

  17. Tubing erosion of an inflatable penile prosthesis long after implantation.

    PubMed

    Morales, Alvaro

    2014-06-01

    Erosion through skin of connecting tubing of an inflatable penile prosthesis (IPP) has not been previously reported. The aim of this study was to present a case of tubing erosion, review the pertinent literature, and discuss the possible causes and management options, including preservation of the device and its components. A 42-year-old male failing to respond to medical treatment for erectile dysfunction underwent insertion of an AMS 700 IPP in 1986. Six years later, a revision was necessary because of a leak in the right cylinder and 4 years after, the pump was replaced. Fourteen years after the original implant, he presented with a portion of the tube connecting the pump to the right cylinder eroding through the skin. There was no infection. The skin area involved was resected and the original pump and tubing were buried in a new scrotal pocket after thorough irrigation. The IPP remained in place, allowing vaginal penetration and without infection for another 11 years. Three years later, it was de-functionalized, converted into a fixed volume device. It eventually was replaced 25 years after originally implanted with a semirigid prosthesis because it did not provide sufficient rigidity and because of concerns about the presence of "screws" detected during pelvic imaging. Mechanical failures in the early IPP models, as illustrated in this case, were expected. However, the long survival of the device is remarkable. Erosion of the connecting tubing through the skin is unique and, under exceptional circumstances, may be managed conservatively without replacing components of the IPP. Clinicians unfamiliar with procedures involving inflatable devices need to be aware of "foreign bodies" visible in radiological examinations in men who have had revisions of an IPP. Morales A. Tubing erosion of an inflatable penile prosthesis long after implantation. Sex Med 2014;2:103-106.

  18. Texture control of zircaloy tubing during tube reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagai, N.; Kakuma, T.; Fujita, K.

    1982-01-01

    Seven batches of Zircaloy-2 nuclear fuel cladding tubes with different textures were processed from tube shells of the same size, by different reduction routes, using pilger and 3-roll mills. Based on the texture data of these tubes, the texture control of Zircaloy tubing, the texture gradient across the wall, and the texture change during annealing were studied. The deformation texture of Zicaloy-2 tubing was dependent on the tool's curvature and was independent of the dimensions of the mother tubes. The different slopes of texture gradients were observed between the tubing of higher strain ration and that of lower strain ratio.

  19. Facility target insert shielding assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mocko, Michal

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In themore » present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.« less

  20. WITHDRAWN: Grommets (ventilation tubes) for recurrent acute otitis media in children.

    PubMed

    Lau, Loretta; Mick, Paul; Nunez, Desmond A

    2018-04-06

    This is an update of a Cochrane review first published in The Cochrane Library in Issue 4, 2008 and previously updated in 2011.Acute suppurative otitis media is one of the most common infectious diseases in childhood. Recurrent acute otitis media is defined for the purposes of this review as either three or more acute infections of the middle ear cleft in a six-month period, or at least four episodes in a year. Strategies for managing the condition include the assessment and modification of risk factors where possible, repeated courses of antibiotics for each new infection, antibiotic prophylaxis and the insertion of ventilation tubes (grommets). To establish whether grommet insertion reduces the frequency of episodes of recurrent acute otitis media and the proportion of symptomatic children. The Cochrane Ear, Nose and Throat Disorders Group (CENTDG) Trials Search Co-ordinator searched the CENTDG Trials Register; Central Register of Controlled Trials (CENTRAL 2014, Issue 10); PubMed; EMBASE; CINAHL; Web of Science; Clinicaltrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 6 November 2014. Randomised controlled trials comparing grommet insertion versus control (antibiotics/other treatments/no treatment) for recurrent acute otitis media in children aged from 0 to 16 years. Two authors independently selected studies. Three authors independently assessed study quality and extracted data. We synthesised data descriptively. Two randomised controlled trials with a total of 148 participants are included in this review. The overall risk of bias in the studies is unclear.The first study randomised 95 children to grommets or control (antibiotic treatment of acute otitis media episodes). For the primary outcome, this study showed that grommet insertion leads to a mean reduction of 1.5 episodes of acute otitis media in the first six months after treatment. In six months of follow-up significantly more children in the

  1. Sensitivity and specificity of eustachian tube function tests in adults.

    PubMed

    Doyle, William J; Swarts, J Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M

    2013-07-01

    The study demonstrates the utility of eustachian tube (ET) function (ETF) test results for accurately assigning ears to disease state. To determine if ETF tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and to define the interrelatedness of ETF test parameters. Through use of the forced-response, inflation-deflation, Valsalva, and sniffing tests, ETF was evaluated in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). Data were analyzed using logistic regression including each parameter independently and then a step-down discriminant analysis including all ETF test parameters to predict group assignment. Factor analysis operating over all parameters was used to explore relatedness. ETF testing. ETF parameters for the forced response, inflation-deflation, Valsalva, and sniffing tests measured in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). The discriminant analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency, and percentage of positive pressure equilibrated) that together correctly assigned ears to group 2 at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters: the first had negative loadings of the ETF structural parameters; the second had positive loadings of the muscle-assisted ET opening parameters; and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. These results show that ETF tests can correctly assign individual ears to

  2. Strength of SiCf-SiCm composite tube under uniaxial and multiaxial loading

    NASA Astrophysics Data System (ADS)

    Shapovalov, Kirill; Jacobsen, George M.; Alva, Luis; Truesdale, Nathaniel; Deck, Christian P.; Huang, Xinyu

    2018-03-01

    The authors report mechanical strength of nuclear grade silicon carbide fiber reinforced silicon carbide matrix composite (SiCf-SiCm) tubing under several different stress states. The composite tubing was fabricated via a Chemical Vapor Infiltration (CVI) process, and is being evaluated for accident tolerant nuclear fuel cladding. Several experimental techniques were applied including uniaxial tension, elastomer insert burst test, open and closed end hydraulic bladder burst test, and torsion test. These tests provided critical stress and strain values at proportional limit and at ultimate failure points. Full field strain measurements using digital image correlation (DIC) were obtained in order to acquire quantitative information on localized deformation during application of stress. Based on the test results, a failure map was constructed for the SiCf-SiCm composites.

  3. CobraPLA Insertion by anesthetists and non-anesthetists wearing unconventional protective gear: a prospective study in humans.

    PubMed

    Ben-Abraham, Ron; Flaishon, Ron; Sotman, Alexander; Ekstein, Perla; Ezri, Tiberiu; Ogorek, Daniel; Weinbroum, Avi A

    2008-07-01

    The threat of a mass casualty unconventional attack has challenged the medical community to devise means for providing rapid and reliable emergent airway control under chaotic conditions by inexperienced medical personnel dressed in self protective gear. Since endotracheal intubation may not be feasible under those conditions, other extraglottic devices should be considered. We assessed the performance of anesthesia and non-anesthesia residents in inserting the CobraPLA, a supraglottic airway device, on consecutive anesthetized patients, to assess its potential use under simulated conditions. Anesthesia and non-anesthesia residents wearing either surgical scrubs or complete anti-chemical gear inserted the CobraPLA in anesthetized patients. If post-trial positive pressure ventilation via the CobraPLA was unsuccessful, an LMA or endotracheal tube was inserted in its stead. It took anesthesia residents 57+/-23 sec and 43+/-13 sec (P<0.05) to place the CobraPLA while wearing anti-chemical gear and surgical scrubs, respectively. Non-anesthesia residents wearing anti-chemical gear performed worse than anesthetists in their first insertion (73+/-9 sec, P<0.05), but after the brief training period they performed as well as their colleagues anesthetists (58+/-10 sec, P=NS). Post-trial, twenty-one CobraPLA (42%) leaked, preventing adequate positive-pressure ventilation: 13 devices (26% of the total) required replacements. Anti-chemical protective gear slowed the insertion of the CobraPLA by anesthetists, and more so by other residents inexperienced in airway management. In 26% of the cases CobraPLA was inadequate for positive pressure ventilation.

  4. Inserts Automatically Lubricate Ball Bearings

    NASA Technical Reports Server (NTRS)

    Hager, J. A.

    1983-01-01

    Inserts on ball-separator ring of ball bearings provide continuous film of lubricant on ball surfaces. Inserts are machined or molded. Small inserts in ball pockets provide steady supply of lubricant. Technique is utilized on equipment for which maintenance is often poor and lubrication interval is uncertain, such as household appliances, automobiles, and marine engines.

  5. PLC-Mediated Signaling Pathway in Pollen Tubes Regulates the Gametophytic Self-incompatibility of Pyrus Species.

    PubMed

    Qu, Haiyong; Guan, Yaqin; Wang, Yongzhang; Zhang, Shaolin

    2017-01-01

    Among the Rosaceae species, the gametophytic self-incompatibility (GSI) is controlled by a single multi-allelic S locus, which is composed of the pistil-S and pollen-S genes. The pistil-S gene encodes a polymorphic ribonuclease (S-RNase), which is essential for identifying self-pollen. However, the S-RNase system has not been fully characterized. In this study, the self-S-RNase inhibited the Ca 2+ -permeable channel activity at pollen tube apices and the selectively decreased phospholipase C ( PLC ) activity in the plasma membrane of Pyrus pyrifolia pollen tubes. Self-S-RNase decreased the Ca 2+ influx through a PLC -mediated signaling pathway. Phosphatidylinositol-specific PLC has a 26-amino acid insertion in pollen tubes of the 'Jinzhuili' cultivar, which is a spontaneous self-compatible mutant of the 'Yali' cultivar. 'Yali' plants exhibit a typical S-RNase-based GSI. Upon self-pollination, PLC gene expression is significantly higher in 'Jinzhuili' pollen tubes than that in 'Yali' pollen tubes. Moreover, the PLC in pollen tubes can only interact with one of the two types of S-RNase from the style. In the Pyrus x bretschneideri Rehd, the PLC directly interacted with the S 7 -RNase in the pollen tube, but not with the S 34 -RNase. Collectively, our results reveal that the effects of S-RNase on PLC activity are required for S-specific pollen rejection, and that PLC -IP 3 participates in the self-incompatibility reaction of Pyrus species.

  6. Development of a highly sensitive one-tube nested real-time PCR for detecting Mycobacterium tuberculosis.

    PubMed

    Choi, Yeonim; Jeon, Bo-Young; Shim, Tae Sun; Jin, Hyunwoo; Cho, Sang-Nae; Lee, Hyeyoung

    2014-12-01

    Rapid, accurate detection of Mycobacterium tuberculosis is crucial in the diagnosis of tuberculosis (TB), but conventional diagnostic methods have limited sensitivity and specificity or are time consuming. A new highly sensitive nucleic acid amplification test, combined nested and real-time polymerase chain reaction (PCR) in a single tube (one-tube nested real-time PCR), was developed for detecting M. tuberculosis, which takes advantage of two PCR techniques, i.e., nested PCR and real-time PCR. One-tube nested real-time PCR was designed to have two sequential reactions with two sets of primers and dual probes for the insertion sequence (IS) 6110 sequence of M. tuberculosis in a single closed tube. The minimum limits of detection of IS6110 real-time PCR and IS6110 one-tube nested real-time PCR were 100 fg/μL and 1 fg/μL of M. tuberculosis DNA, respectively. AdvanSure TB/non-tuberculous mycobacteria (NTM) real-time PCR, IS6110 real-time PCR, and two-tube nested real-time PCR showed 100% sensitivity and 100% specificity for clinical M. tuberculosis isolates and NTM isolates. In comparison, the sensitivities of AdvanSure TB/NTM real-time PCR, single IS6110 real-time PCR, and one-tube nested real-time PCR were 91% (152/167), 94.6% (158/167), and 100% (167/167) for sputum specimens, respectively. In conclusion, IS6110 one-tube nested real-time PCR is useful for detecting M. tuberculosis due to its high sensitivity and simple manipulation. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. EUVL back-insertion layout optimization

    NASA Astrophysics Data System (ADS)

    Civay, D.; Laffosse, E.; Chesneau, A.

    2018-03-01

    Extreme ultraviolet lithography (EUVL) is targeted for front-up insertion at advanced technology nodes but will be evaluated for back insertion at more mature nodes. EUVL can put two or more mask levels back on one mask, depending upon what level(s) in the process insertion occurs. In this paper, layout optimization methods are discussed that can be implemented when EUVL back insertion is implemented. The layout optimizations can be focused on improving yield, reliability or density, depending upon the design needs. The proposed methodology modifies the original two or more colored layers and generates an optimized single color EUVL layout design.

  8. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma.

    PubMed

    Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S

    2017-01-01

    To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p < 0.001) on significantly fewer ocular hypertensive medications (1.3 ± 1.6, p = 0.001) at a mean follow-up of 10 months. Mean IOP reduction at last follow-up was 49%. There were three cases of surgical failures: One case of hypotony, one case of tube extrusion with subsequent explan-tation, and one case requiring second tube insertion for IOP control. Implantation of an Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.

  9. Innovative Technique for the Placement of the Drainage Tube for Microendoscopic Spinal Decompression.

    PubMed

    Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2017-02-01

    A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.

  10. [Inserts for foot deformities].

    PubMed

    Stinus, H; Weber, F

    2005-08-01

    Inserts are orthopedic aids in the treatment of foot disorders that result from changes of the static or dynamic situation. Provision of appropriate orthopedic devices can relieve the pain caused by forefoot deformities either in lieu of surgical intervention or in rare cases also following surgical treatment to improve the symptoms of residual pain.Available materials provide support, padding, and cushioning. Inserts are custom-made to measure and/or based on a plaster impression. Determining the indication, prescribing the inlay, and checking the orthosis are the tasks of the physician. One treatment option for relieving the pain of forefoot deformities consists in conservative therapy with an insert combining features of padding and support as well as adjusting a ready-made shoe. The shoe and inlay should constitute a functional unit since often the optimal effect is only achieved with a combination of insert and orthopedic adjustment of the ready-made shoe.

  11. Human lamina cribrosa insertion and age.

    PubMed

    Sigal, Ian A; Flanagan, John G; Lathrop, Kira L; Tertinegg, Inka; Bilonick, Richard

    2012-10-03

    To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age. The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the total area of insertion and fraction of LC inserting into the pia. Linear mixed effect models were used to determine if the measurements were associated with age or IOP. We analyzed 21 eyes from 11 individuals between 47 and 91 years old. The LC inserted into the pia in all eyes. The fraction of LC inserting into the pia (2.2%-29.6%) had a significant decrease with age (P = 0.049), which resulted from a nonsignificant increase in the total area of LC insertion (P = 0.41) and a nonsignificant decrease in the area of LC insertion into the pia (P = 0.55). None of the measures was associated with fixation IOP (P values 0.44-0.81). Differences between fellow eyes were smaller than differences between unrelated eyes. The LC insertion into the pia mater is common in middle-aged and older eyes, and does not increase with age. The biomechanical and vascular implications of the LC insertion into the pia mater are not well understood and should be investigated further.

  12. A novel quick transendoscopic enteral tubing in mid-gut: technique and training with video.

    PubMed

    Long, Chuyan; Yu, Yan; Cui, Bota; Jagessar, Sabreen Abdul Rahman; Zhang, Jie; Ji, Guozhong; Huang, Guangming; Zhang, Faming

    2018-03-13

    This study aimed to evaluate the feasibility, safety, and value of a quick technique for transendoscopic enteral tubing (TET) through mid-gut. A prospective interventional study was performed in a single center. A TET tube was inserted into mid-gut through the nasal orifice and fixed on the pylorus wall by one tiny titanium endoscopic clip under anesthesia. The feasibility, safety, success rate, and satisfaction with TET placement were evaluated for enteral nutrition or fecal microbiota transplantation. A total of 86 patients underwent mid-gut TET. The success rate of the TET procedure was 98.8% (85/86). Mean tubing time of the TET procedure was 4.2 ± 1.9 min. 10 cases of procedure was enough for training of general endoscopist to shorten the procedure time (7.0 min vs 4.0 min, p < 0.05). 97.7% (84/86) of patients were satisfied with the TET placement. Procedure-related and tube-related adverse events were observed in 8.1% (7/86) and 7.0% (6/86) of patients respectively. There were no moderate to severe adverse events during tube extubation. TET through mid-gut is a novel, convenient, reliable and safe procedure for mid-gut administration with a high degree of patient satisfaction. This research was retrospectively registered with clinicaltrials.gov. Trial registration date: 29th November 2017. NCT03335982 .

  13. Purposeful creation of a pneumothorax and chest tube placement to facilitate CT-guided coil localization of lung nodules before video-assisted thoracoscopic surgical wedge resection.

    PubMed

    Iqbal, Shams I; Molgaard, Christopher; Williamson, Christina; Flacke, Sebastian

    2014-07-01

    To evaluate the feasibility and efficacy of pneumothorax creation and chest tube insertion before computed tomography (CT)-guided coil localization of small peripheral lung nodules for video-assisted thoracoscopic surgical (VATS) wedge resection. From May 2011 to October 2013, 21 consecutive patients (seven men; mean age, 62 y; range, 42-76 y) scheduled for VATS wedge resection required CT-guided coil localization for small, likely nonpalpable peripheral lung lesions at a single institution. Outcomes were evaluated retrospectively for technical success and complications. There were 12 nodules and nine ground-glass opacities. Mean lesion distance from the pleural surface was 15 mm (range, 5-35 mm), and average size was 13 mm (range, 7-30 mm). A pneumothorax was successfully created in all patients with a Veress needle, and a chest tube was inserted. All target lesions were marked successfully, leaving one end of the coil within/beyond the lesion and the other end of the coil in the pleural space. The inserted chest tube was used to insufflate air to widen the pleural space during coil positioning and to aspirate any residual air before transfer of the patient to the operating room holding area. Intraparenchymal hemorrhages smaller than 7 cm in diameter developed in two patients during coil placement. All lesions were successfully resected with VATS. Histologic examinaiton revealed 13 primary adenocarcinomas, four metastases, and four benign lesions. Pneumothorax creation and chest tube placement before CT-guided coil localization of peripheral lung nodules for VATS wedge resection facilitates the deployment of the peripheral end of the coil in the pleural space and provides effective management of procedure-related pneumothorax until surgery. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  14. Safety and Efficacy of Electromagnetic-Guided Bedside Placement of Nasoenteral Feeding Tubes versus Standard Placement.

    PubMed

    Shadid, Husam; Keckeisen, Maureen; Zarrinpar, Ali

    2017-10-01

    Although enteral feeding in critically ill patients has been shown to be beneficial, reliable postpyloric placement of feeding tubes remains a challenge. The standard of care involves blind placement, frequently requiring multiple attempts, and radiographs. To evaluate the effect of electromagnetic-guided bedside placement in reducing time to establishment of feeding, lung placement, use of radiography, and cost, we initiated a prospective trial using electromagnetic-guided bedside placement and compared them to a retrospective cohort. Fifty-three consecutive placements of nasoenteral feeding tubes were made using electromagnetic-guidance on patients requiring enteral nutrition in a surgical intensive care unit at a tertiary care center. Sixty-three placement attempts in the preceding seven months served as controls. There were no significant differences between the two groups in terms of age, sex, weight, body mass index, hiatal or ventral hernias, or previous esophageal/gastric operations. The number of radiographs needed per patient, need for fluoroscopy, radiology charge per patient for the tube placement, and time from first attempt at placement to confirmation of postpyloric location were lower for the electromagnetic-guided group. Use of electromagnetic guidance allows reliable and cost-effective postpyloric enteral feeding tube placement compared with blind insertion.

  15. In vivo evaluation of needle force and friction stress during insertion at varying insertion speed into the brain.

    PubMed

    Casanova, Fernando; Carney, Paul R; Sarntinoranont, Malisa

    2014-11-30

    Convection enhanced delivery (CED) infuses drugs directly into brain tissue. Needle insertion is required and results in tissue damage which can promote flowback along the needle track and improper targeting. The goal of this study was to evaluate friction stress (calculated from needle insertion force) as a measure of tissue contact and damage during needle insertion for varying insertion speeds. Forces and surface dimpling during needle insertion were measured in rat brain in vivo. Needle retraction forces were used to calculate friction stresses. These measures were compared to track damage from a previous study. Differences between brain tissues and soft hydrogels were evaluated for varying insertion speeds: 0.2, 2, and 10mm/s. In brain tissue, average insertion force and surface dimpling increased with increasing insertion speed. Average friction stress along the needle-tissue interface decreased with insertion speed (from 0.58 ± 0.27 to 0.16 ± 0.08 kPa). Friction stress varied between brain regions: cortex (0.227 ± 0.27 kPa), external capsule (0.222 ± 0.19 kPa), and CPu (0.383 ± 0.30 kPa). Hydrogels exhibited opposite trends for dimpling and friction stress with insertion speed. Previously, increasing needle damage with insertion speed has been measured with histological methods. Friction stress appears to decrease with increasing tissue damage and decreasing tissue contact, providing the potential for in vivo and real time evaluation along the needle track. Force derived friction stress decreased with increasing insertion speed and was smaller within white matter regions. Hydrogels exhibited opposite trends to brain tissue. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Human Lamina Cribrosa Insertion and Age

    PubMed Central

    Sigal, Ian A.; Flanagan, John G.; Lathrop, Kira L.; Tertinegg, Inka; Bilonick, Richard

    2012-01-01

    Purpose. To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age. Methods. The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the total area of insertion and fraction of LC inserting into the pia. Linear mixed effect models were used to determine if the measurements were associated with age or IOP. Results. We analyzed 21 eyes from 11 individuals between 47 and 91 years old. The LC inserted into the pia in all eyes. The fraction of LC inserting into the pia (2.2%–29.6%) had a significant decrease with age (P = 0.049), which resulted from a nonsignificant increase in the total area of LC insertion (P = 0.41) and a nonsignificant decrease in the area of LC insertion into the pia (P = 0.55). None of the measures was associated with fixation IOP (P values 0.44–0.81). Differences between fellow eyes were smaller than differences between unrelated eyes. Conclusions. The LC insertion into the pia mater is common in middle-aged and older eyes, and does not increase with age. The biomechanical and vascular implications of the LC insertion into the pia mater are not well understood and should be investigated further. PMID:22956611

  17. Timing of Tympanostomy Tube Placement and Efficacy of Palatoplasty Technique on the Resolution of Chronic Otitis Media: A Cross-sectional Analysis

    PubMed Central

    Brgoch, M. S.; Dodson, K. M.; Kim, T. C.; Kim, D. M.; Rhodes, J. L.

    2015-01-01

    Background: Chronic otitis media with effusion is a persistent complication essentially universal in children with cleft palate. The prevalence of chronic otitis media with effusion is hypothesized to be a result of Eustachian tube dysfunction secondary to the anomalous insertion of the palatal musculature. This study was designed to evaluate the timing of tympanostomy tube placement and the effect of primary palatoplasty technique on the recovery of Eustachian tube function and resolution of chronic otitis media with effusion. Methods: We performed a retrospective, cross-sectional analysis of the previous 99 consecutive patients who underwent a palatoplasty at our institution. Variables included timing of initial tympanostomy tube placement, palatoplasty technique, cleft type, and gender. These were then evaluated to assess their impact on the resolution of chronic otitis media with effusion. Resolution was established as an inverse function of the number of tympanostomy tubes placed in correlation with available audiometric/tympanographic data. For all models, a generalized linear mixed model was applied using a Poisson distribution and a log-link function where the outcome variable was the total number of tympanostomy tubes. For all tests, a P = .05 level of significance was used. Results: Of 99 palatoplasties performed, 94 patients were included in the study. Ninety-one percent of patients had documented chronic otitis media with effusion at the time of palatoplasty. Forty-four percent underwent straight-line repair with aggressive intravelar veloplasty, 36% had Furlow double z-plasty, 20% had straight-line repair without intravelar veloplasty. There was a statistically significant difference (F2,83 = 5.36, P = .0065) between the 3 types of repair. The mean number of tubes placed was 0.6000 ± 0.1225, 0.8519 ± 0.1776, and 1.4737 ± 0.2785 for intravelar veloplasty, Furlow double z-plasty, and straight line without intravelar veloplasty, respectively . With

  18. The cell wall of the Arabidopsis pollen tube--spatial distribution, recycling, and network formation of polysaccharides.

    PubMed

    Chebli, Youssef; Kaneda, Minako; Zerzour, Rabah; Geitmann, Anja

    2012-12-01

    The pollen tube is a cellular protuberance formed by the pollen grain, or male gametophyte, in flowering plants. Its principal metabolic activity is the synthesis and assembly of cell wall material, which must be precisely coordinated to sustain the characteristic rapid growth rate and to ensure geometrically correct and efficient cellular morphogenesis. Unlike other model species, the cell wall of the Arabidopsis (Arabidopsis thaliana) pollen tube has not been described in detail. We used immunohistochemistry and quantitative image analysis to provide a detailed profile of the spatial distribution of the major cell wall polymers composing the Arabidopsis pollen tube cell wall. Comparison with predictions made by a mechanical model for pollen tube growth revealed the importance of pectin deesterification in determining the cell diameter. Scanning electron microscopy demonstrated that cellulose microfibrils are oriented in near longitudinal orientation in the Arabidopsis pollen tube cell wall, consistent with a linear arrangement of cellulose synthase CESA6 in the plasma membrane. The cellulose label was also found inside cytoplasmic vesicles and might originate from an early activation of cellulose synthases prior to their insertion into the plasma membrane or from recycling of short cellulose polymers by endocytosis. A series of strategic enzymatic treatments also suggests that pectins, cellulose, and callose are highly cross linked to each other.

  19. PLC-Mediated Signaling Pathway in Pollen Tubes Regulates the Gametophytic Self-incompatibility of Pyrus Species

    PubMed Central

    Qu, Haiyong; Guan, Yaqin; Wang, Yongzhang; Zhang, Shaolin

    2017-01-01

    Among the Rosaceae species, the gametophytic self-incompatibility (GSI) is controlled by a single multi-allelic S locus, which is composed of the pistil-S and pollen-S genes. The pistil-S gene encodes a polymorphic ribonuclease (S-RNase), which is essential for identifying self-pollen. However, the S-RNase system has not been fully characterized. In this study, the self-S-RNase inhibited the Ca2+-permeable channel activity at pollen tube apices and the selectively decreased phospholipase C (PLC) activity in the plasma membrane of Pyrus pyrifolia pollen tubes. Self-S-RNase decreased the Ca2+ influx through a PLC-mediated signaling pathway. Phosphatidylinositol-specific PLC has a 26-amino acid insertion in pollen tubes of the ‘Jinzhuili’ cultivar, which is a spontaneous self-compatible mutant of the ‘Yali’ cultivar. ‘Yali’ plants exhibit a typical S-RNase-based GSI. Upon self-pollination, PLC gene expression is significantly higher in ‘Jinzhuili’ pollen tubes than that in ‘Yali’ pollen tubes. Moreover, the PLC in pollen tubes can only interact with one of the two types of S-RNase from the style. In the Pyrus x bretschneideri Rehd, the PLC directly interacted with the S7-RNase in the pollen tube, but not with the S34-RNase. Collectively, our results reveal that the effects of S-RNase on PLC activity are required for S-specific pollen rejection, and that PLC-IP3 participates in the self-incompatibility reaction of Pyrus species. PMID:28729872

  20. How to secure the connection between thoracostomy tube and drainage system?

    PubMed

    Li, Ka Ki Pat; Wong, Kit Shing John; Wong, Yau Hang Henry; Cheng, Ka Lok; So, Fung Ling; Lau, Chu Leung; Kam, Chak Wah

    2014-01-01

    Thoracostomy tube insertion is one of the common bedside procedures in emergency medicine and many acute specialties. Dislodgement of thoracostomy tube from the connection tube of chest drainage system is an important problem with potential complications such as contamination, infection and pneumothorax. Besides, mere loosening can also lead to malfunction. It is a common practice to tape the connection of the system. This study aimed to evaluate the materials and methods of connection of chest drain system to minimize drainage dislodgement. We conducted an experimental study to assess the tightness of the connection with various taping materials and methods. We selected three commonly used adhesive materials (3M™ Transpore™ Medical tape, 3M™ Micropore™ Medical tape, 3M™ Soft Cloth Tape on Liner) and three different methods (cross method, straight method, nylon band) to secure the junction between the thoracostomy tube and the bi-conical adaptor in the drainage system. The measured outcome was the weight causing visible loosening of the junction between thoracotomy tube and the adaptor. For each taping material and taping method, 10 trials were performed. The median weight required to disconnect the junction is 26.22 lb for Transpore™, 31.29 lb for Micropore™ and 32.44 lb for Soft Cloth Tape on Liner. A smaller force was required to disconnect if Transpore™ is used (P<0.001). There was no statistical significant difference between Micropore™ and Soft Cloth Tape on Liner (P=0.98). The median disconnecting force is 32.44 lb for straight taping method, 40.55 lb for cross taping method and 21.15 lb for plastic band. The cross-taping method was the more secure method (P<0.0001 when compared with plastic band) (P=0.033 when compared with straight method). Cross-taping is the most secure method among the tested varieties in connecting the thoracostomy tube to the chest drainage system. Transpore™ is not a recommended material for thoracostomy tube

  1. Novel fiber-based technique for inspection of holes in narrow-bore tubes

    NASA Astrophysics Data System (ADS)

    Bernard, Fabien; Flaherty, Tony; O'Connor, Gerard M.

    2009-06-01

    Optical tools offer a route to increasing throughput and efficiency in industrial inspection operations, one of the most time-consuming and labour-intensive aspects of modern manufacturing. One prominent example in the medical device industry is inspection of drilled holes, particularly in narrow-bore tubes (precision-flow devices, such as catheters for drug delivery, radio-opaque contrast agents, etc). The products in which these holes feature are increasing in complexity (reduced dimensions, increasing number of drilled features- in some products now reaching into the hundreds). These trends present a number of technical challenges, not least to ensure that holes are completed and that no damage to the part occurs as a result of over-drilling, for example. This paper will present a novel sensor based on back-side illumination of the drilled hole using side-glowing optical fibers to detect, qualify and quantify drilled holes. The concept is based on inserting a laser-coupled side-glowing optical fiber into the lumen of the tube to be drilled, and imaging the light emitted from this fiber through a drilled hole using a vision system mounted external to the tube. The light from the fiber allows rapid determination of hole completion, shape and size, as well as quantity in the case of products with multiple holes. If the fiber is mounted in the tube prior to drilling, the light emitted from the fiber can be used as a real-time hole breakthrough sensor, preventing under or overdrilling of the tube.

  2. Effect of Off-Axis Screw Insertion, Insertion Torque, and Plate Contouring on Locked Screw Strength

    PubMed Central

    Gallagher, Bethany; Silva, Matthew J.; Ricci, William M.

    2015-01-01

    Objectives This study quantifies the effects of insertion torque, off-axis screw angulation, and plate contouring on the strength of locking plate constructs. Methods Groups of locking screws (n = 6–11 screws) were inserted at 50%, 100%, 150%, and 200% of the manufacturer-recommended torque (3.2 Nm) into locking compression plates at various angles: orthogonal (control), 5-degree angle off-axis, and 10-degree angle off-axis. Screws were loaded to failure by a transverse force (parallel to the plate) either in the same (“+”) or opposite direction (“−”) of the initial screw angulation. Separately, locking plates were bent to 5 and 10-degree angles, with the bend apex at a screw hole. Locking screws inserted orthogonally into the apex hole at 100% torque were loaded to failure. Results Orthogonal insertion resulted in the highest average load to failure, 2577 ± 141 N (range, 2413–2778 N), whereas any off-axis insertion significantly weakened constructs (165–1285 N, at 100% torque) (P < 0.05). For “+” loading, torque beyond 100% did not increase strength, but 50% torque reduced screw strength (P < 0.05). Loading in the “−” direction consistently resulted in higher strengths than “+” loading (P < 0.05). Plate contouring of 5-degree angle did not significantly change screw strength compared with straight plates but contouring of 10-degree angle significantly reduced load to failure (P < 0.05). Conclusions To maximize the screw plate interface strength, locking screws should be inserted without cross-threading. The mechanical stability of locked screws is significantly compromised by loose insertion, off-axis insertion, or severe distortion of the locking mechanism. PMID:24343255

  3. Experiments of draining and filling processes in a collapsible tube at high external pressure

    NASA Astrophysics Data System (ADS)

    Flaud, P.; Guesdon, P.; Fullana, J.-M.

    2012-02-01

    The venous circulation in the lower limb is mainly controlled by the muscular action of the calf. To study the mechanisms governing the venous draining and filling process in such a situation, an experimental setup, composed by a collapsible tube under external pressure, has been built. A valve preventing back flows is inserted at the bottom of the tube and allows to model two different configurations: physiological when the fluid flow is uni-directional and pathological when the fluid flows in both directions. Pressure and flow rate measurements are carried out at the inlet and outlet of the tube and an original optical device with three cameras is proposed to measure the instantaneous cross-sectional area. The experimental results (draining and filling with physiological or pathological valves) are confronted to a simple one-dimensional numerical model which completes the physical interpretation. One major observation is that the muscular contraction induces a fast emptying phase followed by a slow one controlled by viscous effects, and that a defect of the valve decreases, as expected, the ejected volume.

  4. Prospective study of the effects of ventilation tubes on hearing after radiotherapy for carcinoma of nasopharynx

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chowdhury, C.R.; Ho, J.H.; Wright, A.

    1988-03-01

    In patients with nasopharyngeal carcinoma, deafness sometimes occurs following radiotherapy. It is usually conductive, but may be sensorineural. Tinnitus is present frequently and usually is distressing. The role of ventilation tubes (grommets) in relieving these problems was assessed in a prospective randomized controlled trial of 115 patients. In the group with grommets, there was an improvement in hearing, with a reduction of the averaged air-bone gap (p less than .01). This was not found in the control group without ventilation tubes, who developed a larger conductive loss (p less than .01) and, in addition, a slight deterioration of the averagedmore » bone conduction threshold (p less than .01). Surprisingly, the group with grommets did not develop this sensorineural loss (p less than .01). In addition, tinnitus was improved significantly by the insertion of ventilation tubes (p less than .01). Neither necrosis nor stenosis of the external auditory meatus was found in either group.« less

  5. Prospective study of the effects of ventilation tubes on hearing after radiotherapy for carcinoma of nasopharynx

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chowdhury, C.R.; Ho, J.H.; Wright, A.

    In patients with nasopharyngeal carcinoma, deafness sometimes occurs following radiotherapy. It is usually conductive, but may be sensorineural. Tinnitus is present frequently and usually is distressing. The role of ventilation tubes (grommets) in relieving these problems was assessed in a prospective randomized controlled trial of 115 patients. In the group with grommets, there was an improvement in hearing, with a reduction of the averaged air-bone gap (p less than .01). This was not found in the control group without ventilation tubes, who developed a larger conductive loss (p less than .01) and, in addition, a slight deterioration of the averagedmore » bone conduction threshold (p less than .01). Surprisingly, the group with grommets did not develop this sensorineural loss (p less than .01). In addition, tinnitus was improved significantly by the insertion of ventilation tubes (p less than .01). Neither necrosis nor stenosis of the external auditory meatus was found in either group.« less

  6. Peer-assisted learning model enhances clinical clerk's procedural skills.

    PubMed

    Huang, Chia-Chang; Hsu, Hui-Chi; Yang, Ling-Yu; Chen, Chen-Huan; Yang, Ying-Ying; Chang, Ching-Chih; Chuang, Chiao-Lin; Lee, Wei-Shin; Lee, Fa-Yauh; Hwang, Shinn-Jang

    2018-05-17

    Failure to transfer procedural skills learned in a laboratory to the bedside is commonly due to a lack of peer support/stimulation. A digital platform (Facebook) allows new clinical clerks to share experiences and tips that help augment their procedural skills in a peer-assisted learning/teaching method. This study aims to investigate the effectiveness of the innovation of using the digital platform to support the transfer of laboratory-trained procedural skills in the clinical units. Volunteer clinical clerks (n = 44) were enrolled into the peer-assisted learning (PAL) group, which was characterized by the peer-assisted learning of procedural skills during their final 3-month clinical clerkship block. Other clerks (n = 51) did not join the procedural skills-specific Facebook group and served as the self-directed learning regular group. The participants in both the PAL and regular groups completed pre- and post-intervention self-assessments for general self-assessed efficiency ratings (GSER) and skills specific self-assessed efficiency ratings (SSSER) for performing vein puncture, intravenous (IV) catheter and nasogastric (NG) tube insertion. Finally, all clerks received the post-intervention 3-station Objective Structured Clinical Skills Examination (OSCE) to test their proficiency for the abovementioned three procedural skills. Higher cumulative numbers of vein punctures, IV catheter insertions and NG tube insertions at the bedside were carried out by the PAL group than the regular group. A greater improvement in GSERs and SSSERs for medical procedures was found in the PAL group than in the regular group. The PAL group obtained higher procedural skills scores in the post-intervention OSCEs than the regular group. Our study suggested that the implementation of a procedural skill-specific digital platform effectively helps clerks to transfer laboratory-trained procedural skills into the clinical units. In comparison with the regular self-directed learning

  7. Gastric residual volume (GRV) and gastric contents measurement by refractometry.

    PubMed

    Chang, Wei-Kuo; McClave, Stephen A; Hsieh, Chung-Bao; Chao, You-Chen

    2007-01-01

    Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion vs delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.

  8. Thought Insertion Clarified

    PubMed Central

    Ratcliffe, Matthew; Wilkinson, Sam

    2016-01-01

    ‘Thought insertion’ in schizophrenia involves somehow experiencing one’s own thoughts as someone else’s. Some philosophers try to make sense of this by distinguishing between ownership and agency: one still experiences oneself as the owner of an inserted thought but attributes it to another agency. In this paper, we propose that thought insertion involves experiencing thought contents as alien, rather than episodes of thinking. To make our case, we compare thought insertion to certain experiences of ‘verbal hallucination’ and show that they amount to different descriptions of the same phenomenon: a quasi-perceptual experience of thought content. We add that the agency/ownership distinction is unhelpful here. What requires explanation is not why a person experiences a type of intentional state without the usual sense of agency, but why she experiences herself as the agent of one type of intentional state rather than another. We conclude by sketching an account of how this might happen. PMID:28123340

  9. Remote Field Eddy Curent Signal Modeling for the Gap Measurement of Neighboring Tubes

    NASA Astrophysics Data System (ADS)

    Jung, H. K.; Lee, D. H.; Lee, Y. S.

    2005-04-01

    The fuel channels in the Canadian Deuterium Uranium (CANDU) reactor consist of the coaxial pressure tube (PT) and the calandria tube (CT). The Liquid injection nozzle (LIN) is cross aligned with the fuel channel to control the reactor by injecting poison. For a safe operation, the gap between the LIN and CT should be maintained in order to prevent a contact of the neighboring tubes. The remote field eddy current (RFEC) method was applied to measure the gap between a nonmagnetic Zircaloy-2 liquid injection nozzle (LIN) and a Zircaloy-2 calandria tube. Under the condition of inserting the RFEC probe into the coaxial tubes and of crossing a LIN above or under the CT, the modeling of a LIN signal is needed to check the possibility of a gap measurement. The Volume Integral Code S/W which covers the axi-symmetric 3D configuration has been very rarely applied to obtain a LIN signal. This problem was solved by assuming a LIN as a flaw which can be described as a complete 3D object. This simulated LIN signal was verified by performing the laboratory experiment. The gap between the LIN and CT can be correlated with the amplitude of the LIN signals in the voltage plane. Typical noises in the fuel channel were the relative constriction, the change in the pressure tube diameter (fill-factor), thickness variation, and so on. These noise signals were simulated by using the modeling and were analyzed by considering their dependency on the phase angle and amplitude of the voltage plane in order to separate the gap signal from them. It could be concluded that the voltage plane analysis of the simulated RFEC signals were effective for obtaining the gap measurement of the neighboring tube.

  10. A rubber tube in the bladder as a complication of autoerotic stimulation of the urethra.

    PubMed

    Stamatiou, Konstantinos; Moschouris, Hippocrates

    2016-10-05

    Self-insertion of foreign bodies in the urethra is most commonly associated with sexual or erotic arousal of adolescents with mental health disorders. Rarely it may practiced by healthy adults for masturbation. Migration of foreign bodies used for the abovementioned purpose from the urethra to adjacent organs is a relatively uncommon urologic problem that may cause serious complications which arose tardive. Presentation includes a variety of acute or chronic symptoms that depend of the underlying complications. The method of extraction depends on the shape, size and nature of the object and should be tailored according to the condition of the patient. In the present article we present a case of a rubber tube inserted to the urethra for erotic arousal purposes which migrated to the bladder during masturbation.

  11. Peritoneal Dialysis Catheter Insertion.

    PubMed

    Crabtree, John H; Chow, Kai-Ming

    2017-01-01

    The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) Furnace Development

    NASA Technical Reports Server (NTRS)

    Crouch, Myscha R.; Carswell, William E.; Farmer, Jeff; Rose, Fred; Tidwell, Paul H., II

    2000-01-01

    The Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) are microgravity furnaces under development at Marshall Space Flight Center. The furnaces are being developed for the first Materials Science Research Rack (MSRR-1) of the Materials Science Research Facility (MSRF), one of the first International Space Station (ISS) scientific payloads. QMI is a Bridgman furnace with quench capability for studying interface behavior during directional solidification of metallic and alloy materials. DMI will be a Bridgman-Stockbarger furnace to study diffusion processes in semiconductors. The design for each insert, both QMI and DMI, is driven by specific science, operations and safety requirements, as well as by constraints arising from resource limitations, such as volume, mass and power. Preliminary QMI analysis and testing indicates that the design meets these requirements.

  13. Effect of the starting point of half-pin insertion on the insertional torque of the pin at the tibia.

    PubMed

    Kim, Sung Jae; Kim, Sung Hwan; Kim, Young Hwan; Chun, Yong Min

    2015-01-01

    The authors have observed a failure to achieve secure fixation in elderly patients when inserting a half-pin at the anteromedial surface of the tibia. The purpose of this study was to compare two methods for inserting a half-pin at tibia diaphysis in elderly patients. Twenty cadaveric tibias were divided into Group C or V. A half-pin was inserted into the tibias of Group C via the conventional method, from the anteromedial surface to the interosseous border of the tibia diaphysis, and into the tibias of Group V via the vertical method, from the anterior border to the posterior surface at the same level. The maximum insertion torque was measured during the bicortical insertion with a torque driver. The thickness of the cortex was measured by micro-computed tomography. The relationship between the thickness of the cortex engaged and the insertion torque was investigated. The maximum insertion torque and the thickness of the cortex were significantly higher in Group V than Group C. Both groups exhibited a statistically significant linear correlation between torque and thickness by Spearman's rank correlation analysis. Half-pins inserted by the vertical method achieved purchase of more cortex than those inserted by the conventional method. Considering that cortical thickness and insertion torque in Group V were significantly greater than those in Group C, we suggest that the vertical method of half-pin insertion may be an alternative to the conventional method in elderly patients.

  14. Chassis unit insert tightening-extract device

    NASA Technical Reports Server (NTRS)

    Haerther, L. W.; Zimmerman, P. A. (Inventor)

    1964-01-01

    The invention relates to the insertion and extraction of rack mounted electronic units and in particular to a screw thread insert tightening and extract device, for chassis units having a collar which may be rotatably positioned manually for the insert tightening or extraction of various associated chassis units, as desired.

  15. Case study involving suctioning of an electromyographic endotracheal tube.

    PubMed

    Evanina, Eileen Youshock; Hanisak, Jill L

    2005-04-01

    The electromyographic endotracheal tube (EMG-ETT) is a relatively new tool used to measure integrity of the vocal cord structures during surgery. We describe a case in which an EMG-ETT was inserted for the operative period but not replaced with an ETT during the immediate postoperative period. Intensive care unit nurses had difficulty suctioning the EMG-ETT. The patient was not provided the pulmonary toilet necessary until the EMG-ETT was removed and replaced with a regular ETT. The purpose of this article is to make anesthesia providers aware that when mechanical ventilation is required during the postoperative period, the EMG-ETT should be removed and replaced with a regular ETT to facilitate pulmonary toilet.

  16. CRISPR/Cas9 cleavages in budding yeast reveal templated insertions and strand-specific insertion/deletion profiles.

    PubMed

    Lemos, Brenda R; Kaplan, Adam C; Bae, Ji Eun; Ferrazzoli, Alexander E; Kuo, James; Anand, Ranjith P; Waterman, David P; Haber, James E

    2018-02-27

    Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.

  17. Determination of tube-to-tube support interaction characteristics. [PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haslinger, K.H.

    Tube-to-tube support interaction characteristics were determined on a multi-span tube geometry representative of the hot-leg side of the C-E, System 80 steam generator design. Results will become input for an autoclave type wear test program on steam generator tubes, performed by Kraftwerk Union (KWU). Correlation of test data reported here with similar data obtained from the wear tests will be performed in an attempt to make predictions about the long-term fretting behavior of steam generator tubes.

  18. Thin chest wall is an independent risk factor for the development of pneumothorax after chest tube removal.

    PubMed

    Anand, Rahul J; Whelan, James F; Ferrada, Paula; Duane, Therese M; Malhotra, Ajai K; Aboutanos, Michel B; Ivatury, Rao R

    2012-04-01

    The factors contributing to the development of pneumothorax after removal of chest tube thoracostomy are not fully understood. We hypothesized that development of post pull pneumothorax (PPP) after chest tube removal would be significantly lower in those patients with thicker chest walls, due to the "protective" layer of adipose tissue. All patients on our trauma service who underwent chest tube thoracostomy from July 2010 to February 2011 were retrospectively reviewed. Patient age, mechanism of trauma, and chest Abbreviated Injury Scale score were analyzed. Thoracic CTs were reviewed to ascertain chest wall thickness (CW). Thickness was measured at the level of the nipple at the midaxillary line, as perpendicular distance between skin and pleural cavity. Chest X-ray reports from immediately prior and after chest tube removal were reviewed for interval development of PPP. Data are presented as average ± standard deviation. Ninety-one chest tubes were inserted into 81 patients. Patients who died before chest tube removal (n = 11), or those without thoracic CT scans (n = 13) were excluded. PPP occurred in 29.9 per cent of chest tube removals (20/67). When PPP was encountered, repeat chest tube was necessary in 20 per cent of cases (4/20). After univariate analysis, younger age, penetrating mechanism, and thin chest wall were found to be significant risk factors for development of PPP. Chest Abbreviated Injury Scale score was similar in both groups. Logistic regression showed only chest wall thickness to be an independent risk factor for development of PPP.

  19. Alternate tube plugging criteria for steam generator tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cueto-Felgueroso, C.; Aparicio, C.B.

    1997-02-01

    The tubing of the Steam Generators constitutes more than half of the reactor coolant pressure boundary. Specific requirements governing the maintenance of steam generator tubes integrity are set in Plant Technical Specifications and in Section XI of the ASME Boiler and Pressure Vessel Code. The operating experience of Steam Generator tubes of PWR plants has shown the existence of some types of degradatory processes. Every one of these has an specific cause and affects one or more zones of the tubes. In the case of Spanish Power Plants, and depending on the particular Plant considered, they should be mentioned themore » Primary Water Stress Corrosion Cracking (PWSCC) at the roll transition zone (RTZ), the Outside Diameter Stress Corrosion Cracking (ODSCC) at the Tube Support Plate (TSP) intersections and the fretting with the Anti-Vibration Bars (AVBs) or with the Support Plates in the preheater zone. The In-Service Inspections by Eddy Currents constitutes the standard method for assuring the SG tubes integrity and they permit the monitoring of the defects during the service life of the plant. When the degradation reaches a determined limit, called the plugging limit, the SG tube must be either repaired or retired from service by plugging. Customarily, the plugging limit is related to the depth of the defect. Such depth is typically 40% of the wall thickness of the tube and is applicable to any type of defect in the tube. In its origin, that limit was established for tubes thinned by wastage, which was the predominant degradation in the seventies. The application of this criterion for axial crack-like defects, as, for instance, those due to PWSCC in the roll transition zone, has lead to an excessive and unnecessary number of tubes being plugged. This has lead to the development of defect specific plugging criteria. Examples of the application of such criteria are discussed in the article.« less

  20. The effect of esophagogastroduodenoscopy probe insertion on the intracuff pressure of airway devices in children during general anesthesia.

    PubMed

    Balaban, Onur; Kamata, Mineto; Hakim, Mumin; Tumin, Dmitry; Tobias, Joseph D

    2017-04-01

    Given the size of the esophagogastroduodenoscopy (EGD) probe and the compressibility of the pediatric airway, the EGD probe may increase the intracuff pressure (IP) of an airway device. The current study evaluated IP changes during EGD examination under general anesthesia in pediatric patients. Following the induction of anesthesia, a laryngeal mask airway (LMA) or endotracheal tube (ETT) was placed without neuromuscular blockade. The IP was measured at baseline, during EGD probe insertion, while the EGD probe was in place, and after probe removal. The study cohort included 101 patients (mean age 11.3 years). The airway was secured with an LMA and an ETT in 88 and 13 patients, respectively. The IP increased from 27 ± 15 cmH 2 O at baseline to 34 ± 17 cmH 2 O during probe insertion (p < 0.001), remained at 33 ± 16 cmH 2 O while the probe was in place, and decreased to 26 ± 14 cmH 2 O after probe removal. The IP of the LMA or ETT increased during EGD probe insertion and remained elevated while the probe was in place. High IP may compromise mucosal perfusion resulting in a sore throat when using an LMA or the potential for airway damage if an ETT is used. Removal of air from the cuff and titration of the IP should be considered after EGD insertion.

  1. Modified endotracheal tube: emergency alternative to paediatric tracheostomy tube.

    PubMed

    Kurien, M; Raviraj, R; Mathew, J; Kaliaperumal, I; Ninan, S

    2011-07-01

    In an emergency, the non-availability of a conventional paediatric tracheostomy tube is a therapeutic challenge for the attending surgeon. To describe a simple alternative to a paediatric tracheostomy tube for use in an emergency situation. Case report of a 14-year-old boy who developed tracheomalacia following partial cricotracheal resection for subglottic stenosis. As a suitably sized tracheostomy tube (with a long narrow segment) was not available, an endotracheal tube was modified and used successfully. Details of the modification, and a relevant literature review, are also discussed. In the paediatric age group, when an appropriately sized tracheostomy tube is not available, a modified endotracheal tube is a simple temporary alternative; this may be especially useful in an emergency.

  2. AtTMEM18 plays important roles in pollen tube and vegetative growth in Arabidopsis

    PubMed Central

    Dou, Xiao‐Ying; Yang, Ke‐Zhen; Ma, Zhao‐Xia; Chen, Li‐Qun; Zhang, Xue‐Qin; Bai, Jin‐Rong

    2016-01-01

    Abstract In flowering plants, pollen tube growth is essential for delivery of male gametes into the female gametophyte or embryo sac for double fertilization. Although many genes have been identified as being involved in the process, the molecular mechanisms of pollen tube growth remains poorly understood. In this study, we identified that the Arabidopsis Transmembrane Protein 18 (AtTMEM18) gene played important roles in pollen tube growth. The AtTMEM18 shares a high similarity with the Transmembrane 18 proteins (TMEM18s) that are conserved in most eukaryotes and may play important roles in obesity in humans. Mutation in the AtTMEM18 by a Ds insertion caused abnormal callose deposition in the pollen grains and had a significant impact on pollen germination and pollen tube growth. AtTMEM18 is expressed in pollen grains, pollen tubes, root tips and other vegetative tissues. The pollen‐rescued assays showed that the mutation in AtTMEM18 also caused defects in roots, stems, leaves and transmitting tracts. AtTMEM18‐GFP was located around the nuclei. Genetic assays demonstrated that the localization of AtTMEM18 around the nuclei in the generative cells of pollen grains was essential for the male fertility. Furthermore, expression of the rice TMEM18‐homologous protein (OsTMEM18) driven by LAT52 promoter could recover the fertility of the Arabidopsis attmem18 mutant. These results suggested that the TMEM18 is important for plant growth in Arabidopsis. PMID:26699939

  3. Testing of self-repairing composite airplane components by use of CAI and the release of the repair chemicals from carefully inserted small tubes

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn

    2007-04-01

    The research on self repair of airplane components, under an SBIR phase II with Wright Patterson Air Force Base, has investigated the attributes and best end use applications for such a technology. These attributes include issues related to manufacturability, cost, potential benefits such as weight reduction, and cost reduction. The goal of our research has been to develop self-repairing composites with unique strength for air vehicles. Our revolutionary approach involves the autonomous release of repair chemicals from within the composite matrix itself. The repair agents are contained in hollow, structural fibers that are embedded within the matrix. Under stress, the composite senses external environmental factors and reacts by releasing the repair agents from within the hollow vessels. This autonomous response occurs wherever and whenever cracking, debonding or other matrix damage transpires. Superior performance over the life of the composite is achieved through this self-repairing mechanism. The advantages to the military would be safely executed missions, fewer repairs and eventually lighter vehicles. In particular the research has addressed the issues by correlating the impact of the various factors, such as 1) delivery vessel placement, shape/size and effect on composite strength, chemicals released and their effect on the matrix, release trigger and efficacy and any impact on matrix properties 2) impact of composite processing methods that involve heat and pressure on the repair vessels. Our self repairing system can be processed at temperatures of 300-350F, repairs in less than 30 seconds and does not damage the composite by repair fiber insertion or chemical release. Scaling up and manufacture of components has revealed that anticipating potential problems allowed us to avoid those associated with processing temperatures and pressures. The presentation will focus on compression after impact testing and the placement of repair fibers/tubes into prepreg

  4. A backing device based on an embedded stiffener and retractable insertion tool for thin-film cochlear arrays

    NASA Astrophysics Data System (ADS)

    Tewari, Radheshyam

    Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based biodegradable and water soluble adhesive, that will help to retract the PET insertion tool after implantation. As a proof-of-concept of sub-system one, a microfabrication process for patterning PLA stiffeners embedded in parylene has been developed. Conventional hot-embossing, mechanical micromachining, and standard cleanroom processes were integrated for patterning fully released and discrete stiffeners coated with parylene. The released embedded stiffeners were thermoformed to demonstrate that imparting perimodiolar shapes to stiffener-embedded arrays will be possible. The developed process when integrated with the array fabrication process will allow fabrication of stiffener-embedded arrays in a single process. As a proof-of-concept of sub-system two, the feasibility of the attaching and detaching mechanism was demonstrated by adhering 1x and 1.5x scale PET tube-based insertion tools and PLA stiffeners embedded in parylene using the copolymer adhesive. The attached devices survived qualitative adhesion tests, thermoforming, and flexing. The viability of the detaching mechanism was tested by aging the assemblies in-vitro in phosphate buffer solution. The average detachment times, 2.6 minutes and 10 minutes

  5. Impact of tube current modulation on lesion conspicuity index in hi-resolution chest computed tomography

    NASA Astrophysics Data System (ADS)

    Szczepura, Katy; Tomkinson, David; Manning, David

    2017-03-01

    Tube current modulation is a method employed in the use of CT in an attempt to optimize radiation dose to the patient. The acceptable noise (noise index) can be varied, based on the level of optimization required; higher accepted noise reduces the patient dose. Recent research [1] suggests that measuring the conspicuity index (C.I.) of focal lesions within an image is more reflective of a clinical reader's ability to perceive focal lesions than traditional physical measures such as contrast to noise (CNR) and signal to noise ratio (SNR). Software has been developed and validated to calculate the C.I. in DICOM images. The aim of this work is assess the impact of tube current modulation on conspicuity index and CTDIvol, to indicate the benefits and limitations of tube current modulation on lesion detectability. Method An anthropomorphic chest phantom was used "Lungman" with inserted lesions of varying size and HU (see table below) a range of Hounsfield units and sizes were used to represent the variation in lesion Hounsfield units found. This meant some lesions had negative Hounsfield unit values.

  6. Sequential cooling insert for turbine stator vane

    DOEpatents

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  7. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    PubMed

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  8. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    PubMed

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  9. Development of an organ-specific insert phantom generated using a 3D printer for investigations of cardiac computed tomography protocols.

    PubMed

    Abdullah, Kamarul A; McEntee, Mark F; Reed, Warren; Kench, Peter L

    2018-04-30

    An ideal organ-specific insert phantom should be able to simulate the anatomical features with appropriate appearances in the resultant computed tomography (CT) images. This study investigated a 3D printing technology to develop a novel and cost-effective cardiac insert phantom derived from volumetric CT image datasets of anthropomorphic chest phantom. Cardiac insert volumes were segmented from CT image datasets, derived from an anthropomorphic chest phantom of Lungman N-01 (Kyoto Kagaku, Japan). These segmented datasets were converted to a virtual 3D-isosurface of heart-shaped shell, while two other removable inserts were included using computer-aided design (CAD) software program. This newly designed cardiac insert phantom was later printed by using a fused deposition modelling (FDM) process via a Creatbot DM Plus 3D printer. Then, several selected filling materials, such as contrast media, oil, water and jelly, were loaded into designated spaces in the 3D-printed phantom. The 3D-printed cardiac insert phantom was positioned within the anthropomorphic chest phantom and 30 repeated CT acquisitions performed using a multi-detector scanner at 120-kVp tube potential. Attenuation (Hounsfield Unit, HU) values were measured and compared to the image datasets of real-patient and Catphan ® 500 phantom. The output of the 3D-printed cardiac insert phantom was a solid acrylic plastic material, which was strong, light in weight and cost-effective. HU values of the filling materials were comparable to the image datasets of real-patient and Catphan ® 500 phantom. A novel and cost-effective cardiac insert phantom for anthropomorphic chest phantom was developed using volumetric CT image datasets with a 3D printer. Hence, this suggested the printing methodology could be applied to generate other phantoms for CT imaging studies. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical

  10. Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices

    PubMed Central

    Khan, Salman Nasir; Shiakolas, Panos S.; Mootha, Venkateswara Vinod

    2015-01-01

    This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK. PMID:27051492

  11. Home enteral nutrition: organisation of services.

    PubMed

    Green, Sue; Dinenage, Sarah; Gower, Morwenna; Van Wyk, Johanna

    2013-05-01

    This article discusses how services for people receiving enteral nutrition via a nasogastric or gastrostomy tube at home are organised. The home enteral nutrition team's role is also explored. The National Institute for Health and Care Excellence outlines the need for nutritional support in adults to be high quality and cost effective. It is important therefore that local services are able to provide people receiving enteral nutrition with safe and effective care that they consider satisfactory. The discussion is pertinent to nurses caring for older people because gastrostomy tube placement is increasingly common in people aged over 60. A gastrostomy tube is the usual route by which enteral nutrition is given in the community.

  12. Controlling the electronic and geometric structures of 2D insertions to realize high performance metal/insertion-MoS2 sandwich interfaces.

    PubMed

    Su, Jie; Feng, Liping; Zeng, Wei; Liu, Zhengtang

    2017-06-08

    Metal/insertion-MoS 2 sandwich interfaces are designed to reduce the Schottky barriers at metal-MoS 2 interfaces. The effects of geometric and electronic structures of two-dimensional (2D) insertion materials on the contact properties of metal/insertion-MoS 2 interfaces are comparatively studied by first-principles calculations. Regardless of the geometric and electronic structures of 2D insertion materials, Fermi level pinning effects and charge scattering at the metal/insertion-MoS 2 interface are weakened due to weak interactions between the insertion and MoS 2 layers, no gap states and negligible structural deformations for MoS 2 layers. The Schottky barriers at metal/insertion-MoS 2 interfaces are induced by three interface dipoles and four potential steps that are determined by the charge transfers and structural deformations of 2D insertion materials. The lower the electron affinities of 2D insertion materials, the more are the electrons lost from the Sc surface, resulting in lower n-type Schottky barriers at Sc/insertion-MoS 2 interfaces. The larger the ionization potentials and the thinner the thicknesses of 2D insertion materials, the fewer are the electrons that accumulate at the Pt surface, leading to lower p-type Schottky barriers at Pt/insertion-MoS 2 interfaces. All Sc/insertion-MoS 2 interfaces exhibited ohmic characters. The Pt/BN-MoS 2 interface exhibits the lowest p-type Schottky barrier of 0.52 eV due to the largest ionization potential (∼6.88 eV) and the thinnest thickness (single atomic layer thickness) of BN. These results in this work are beneficial to understand and design high performance metal/insertion-MoS 2 interfaces through 2D insertion materials.

  13. Prototyping of Poly(dimethylsiloxane) Interfaces for Flow Gating, Reagent Mixing, and Tubing Connection in Capillary Electrophoresis

    PubMed Central

    Zhang, Qiyang; Gong, Maojun

    2014-01-01

    Integrated microfluidic systems coupled with electrophoretic separations have broad application in biological and chemical analysis. Interfaces for the connection of various functional parts play a major role in the performance of a system. Here we developed a rapid prototyping method to fabricate monolithic poly(dimethylsiloxane) (PDMS) Interfaces for flow-gated injection, online reagent mixing, and tube-to-tube connection in an integrated capillary electrophoresis (CE) system. The basic idea was based on the properties of PDMS: elasticity, transparency, and suitability for prototyping. The molds for these interfaces were prepared by using commercially available stainless steel wires and nylon lines or silica capillaries. A steel wire was inserted through the diameter of a nylon line and a cross format was obtained as the mold for PDMS casting of flow gates and 4-way mixers. These interfaces accommodated tubing connection through PDMS elasticity and provided easy visual trouble shooting. The flow gate used smaller channel diameters thus reducing flow rate by 25 fold for effective gating compared with mechanically machined counterparts. Both PDMS mixers and the tube-to-tube connectors could minimize the sample dead volume by using an appropriate capillary configuration. As a whole, the prototyped PDMS interfaces are reusable, inexpensive, convenient for connection, and robust when integrated with the CE detection system. Therefore, these interfaces could see potential applications in CE and CE-coupled systems. PMID:24331370

  14. Peak insertion torque values of five mini-implant systems under different insertion loads.

    PubMed

    Quraishi, Erma; Sherriff, Martyn; Bister, Dirk

    2014-06-01

    To assess the effect of 1 and 3 kg insertion load on five makes of self-drilling mini-implants on peak insertion torque values to establish risk factors involved in the fracture of mini-implants. Two different loads were applied during insertion of 40 mini-implants from five different manufacturers (Dual Top(™) (1·6×8 mm), Infinitas(™) (1·5×9 mm), Ortho Easy(™) (1·7×8 mm), Spider Screw(™) (1·5×8 mm) and Vector TAS(™) (1·4×8 mm)) into acrylic blocks at 8 rev/min utilizing a Motorized Torque Measurement Stand. Peak insertion torque values for both loads were highest for Vector TAS followed by Ortho Easy and Dual Top and were nearly three times higher than Infinitas (original version) and Spider Screws(TM). The log-rank test showed statistically significant differences for both loads for Vector TAS, Ortho Easy and Spider Screws. Unlike other designs tested, both tapered mini-implant designs (Spider Screw and Infinitas) showed a tendency to buckle in the middle of the body but fractured at the tip. Non-tapered mini-implants fractured at significantly higher torque values compared to tapered designs under both loads. Increased pressure resulted in slightly higher maximum torque values at fracture for some of the mini-implant designs, although this is unlikely to be of clinical relevance. Tripling insertion pressure from 1 to 3 kg increased the risk of bending tapered mini-implants before fracture. © 2014 British Orthodontic Society.

  15. Laboratory investigation on the role of tubular shaped micro resonators phononic crystal insertion on the absorption coefficient of profiled sound absorber

    NASA Astrophysics Data System (ADS)

    Yahya, I.; Kusuma, J. I.; Harjana; Kristiani, R.; Hanina, R.

    2016-02-01

    This paper emphasizes the influence of tubular shaped microresonators phononic crystal insertion on the sound absorption coefficient of profiled sound absorber. A simple cubic and two different bodies centered cubic phononic crystal lattice model were analyzed in a laboratory test procedure. The experiment was conducted by using transfer function based two microphone impedance tube method refer to ASTM E-1050-98. The results show that sound absorption coefficient increase significantly at the mid and high-frequency band (600 - 700 Hz) and (1 - 1.6 kHz) when tubular shaped microresonator phononic crystal inserted into the tested sound absorber element. The increment phenomena related to multi-resonance effect that occurs when sound waves propagate through the phononic crystal lattice model that produce multiple reflections and scattering in mid and high-frequency band which increases the sound absorption coefficient accordingly

  16. In-office insertion of a miniaturized insertable cardiac monitor: Results from the Reveal LINQ In-Office 2 randomized study.

    PubMed

    Rogers, John D; Sanders, Prashanthan; Piorkowski, Christopher; Sohail, M Rizwan; Anand, Rishi; Crossen, Karl; Khairallah, Farhat S; Kaplon, Rachelle E; Stromberg, Kurt; Kowal, Robert C

    2017-02-01

    Recent miniaturization of an insertable cardiac monitor (ICM) may make it possible to move device insertion from a hospital to office setting. However, the safety of this strategy is unknown. The primary objective was to compare the safety of inserting the Reveal LINQ ICM in an office vs a hospital environment. Ancillary objectives included summarizing device- and procedure-related adverse events and responses to a physician questionnaire. Five hundred twenty-one patients indicated for an ICM were randomized (1:1 ratio) to undergo ICM insertion in a hospital or office environment at 26 centers in the United States in the Reveal LINQ In-Office 2 study (ClinicalTrials.gov identifier NCT02395536). Patients were followed for 90 days. ICM insertion was successful in all 482 attempted patients (office: 251; hospital: 231). The untoward event rate (composite of unsuccessful insertion and ICM- or insertion-related complications) was 0.8% (2 of 244) in the office and 0.9% (2 of 227) in the hospital (95% confidence interval, -3.0% to 2.9%; 5% noninferiority: P < .001). In addition, adverse events occurred during 2.5% (6 of 244) of office and 4.4% (10 of 227) of hospital insertions (95% confidence interval [office minus inhospital rates], -5.8% to 1.9%; 5% noninferiority: P < .001). Physicians indicated that for procedures performed in an office vs a hospital, there were fewer delays >15 minutes (16% vs 35%; P < .001) and patient response was more often "very positive." Physicians considered the office location "very convenient" more frequently than the hospital location (85% vs 27%; P < .001). The safety profile for the insertion of the Reveal LINQ ICM is excellent irrespective of insertion environment. These results may expand site of service options for LINQ insertion. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Insertion tube methods and apparatus

    DOEpatents

    Casper, William L.; Clark, Don T.; Grover, Blair K.; Mathewson, Rodney O.; Seymour, Craig A.

    2007-02-20

    A drill string comprises a first drill string member having a male end; and a second drill string member having a female end configured to be joined to the male end of the first drill string member, the male end having a threaded portion including generally square threads, the male end having a non-threaded extension portion coaxial with the threaded portion, and the male end further having a bearing surface, the female end having a female threaded portion having corresponding female threads, the female end having a non-threaded extension portion coaxial with the female threaded portion, and the female end having a bearing surface. Installation methods, including methods of installing instrumented probes are also provided.

  18. Chest tube insertion - series (image)

    MedlinePlus

    ... cause the lung to collapse, such as: air leaks from the lung into the chest (pneumothorax) bleeding ... nursing staff will carefully check for possible air leaks, breathing difficulties, and need for additional oxygen. Frequent ...

  19. US Army Medical Department Journal, April-June 2005

    DTIC Science & Technology

    2005-06-01

    systematically assess their practice, and identify Medical Education Directorate and the final link in the medical areas where education can effect...syndrome would nasogastric tube was drained intermittently and otherwise mandate decompressive fasciotomies of the affected extremities vented. Urine...AMEDD Continuum of Medical Education 12 COL John M. Powers, MC, USA The Medical Corps Assignment Process 16 COL Jonathan H. Jaffin, MC, USA, et al

  20. Technical Note: Computer-Manufactured Inserts for Prosthetic Sockets

    PubMed Central

    Sanders, Joan E.; McLean, Jake B.; Cagle, John C.; Gardner, David W.; Allyn, Katheryn J.

    2016-01-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant’s test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11 mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03 mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. PMID:27212209

  1. Technical note: Computer-manufactured inserts for prosthetic sockets.

    PubMed

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Silicone infusion tubing instead of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment.

    PubMed

    Kibadi, K; Moutet, F

    2017-10-01

    The authors describe their experience using silicone infusion tubing in place of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment. This case report features a 47-year-old, right-handed man who had no active PIP and DIP joint flexion in four fingers of the right hand 5 months after an injury. During the first repair stage, the A2 and A4 pulleys were reconstructed using an extensor retinaculum graft. An infusion tube was inserted instead of Hunter rods. During the second stage, formation of a digital neo-canal around the infusion tubing was observed. The infusion tubing was removed and replaced with a palmaris longus tendon graft according to the conventional technique. Physiotherapy and rehabilitation followed surgery. At 6 months, very significant progress had been made with complete recovery of PIP and DIP flexion in the four fingers. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  3. Method Of Wire Insertion For Electric Machine Stators

    DOEpatents

    Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony

    2005-02-08

    A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.

  4. An interaction between levodopa and enteral nutrition resulting in neuroleptic malignant-like syndrome and prolonged ICU stay.

    PubMed

    Bonnici, André; Ruiner, Carola-Ellen; St-Laurent, Lyne; Hornstein, David

    2010-09-01

    To describe a probable interaction between enteral feeds and levodopa leading to neuroleptic malignant-like syndrome (NMLS) in a polytrauma patient with Parkinson's disease (PD). A 63-year-old morbidly obese male polytrauma patient with PD and type 2 diabetes mellitus was admitted to our intensive care unit postoperatively. Enteral feeds were administered per nasogastric tube and provided 0.88 g /kg/day of protein based on ideal body weight (IBW). His PD medications (pramipexole, entacapone, and immediate-release levodopa/carbidopa 100 mg/25 mg, 1.5 tablets 4 times daily) were administered via nasogastric tube. To achieve better glycemic control, his enteral feeds were changed to a formula that provided 1.8 g/kg/day of protein based on IBW. In the following 24 hours, the patient's mental status deteriorated and he was reintubated. He developed a high fever (40.5 degrees C), leukocytosis, elevated serum creatine kinase (CK) (480-1801 units/L), and acute renal impairment. His enteral nutrition was changed to decrease protein intake to 1.0 g/kg/day based on IBW and he was given bromocriptine 5 mg 3 times daily via nasogastric tube. Within 24 hours, the patient's mental status improved, his temperature and CK decreased, and his renal function began to improve; the values returned to baseline levels on the 18th day of admission. Withdrawal or dose reduction of levodopa in patients with PD has been reported to precipitate NMLS, which is potentially fatal. Because dietary protein can decrease the absorp0tion of levodopa, a potential for an interaction between levodopa and enteral feedings exists, although published reports of such an interaction are limited. In this patient, the likelihood that a drug-nutrient interaction occurred between levodopa and enteral feedings is considered to be probable based on the Naranjo probability scale and the Horn Drug Interaction Probability Scale. Health-care professionals should be aware of the interaction between levodopa and protein

  5. Laparoscopic versus open repair for perforated peptic ulcer: A meta analysis of randomized controlled trials.

    PubMed

    Tan, Shanjun; Wu, Guohao; Zhuang, Qiulin; Xi, Qiulei; Meng, Qingyang; Jiang, Yi; Han, Yusong; Yu, Chao; Yu, Zhen; Li, Ning

    2016-09-01

    The role of laparoscopic surgery in the repair for peptic ulcer disease is unclear. The present study aimed to compare the safety and efficacy of laparoscopic versus open repair for peptic ulcer disease. Randomized controlled trials (RCTs) comparing laparoscopic versus open repair for peptic ulcer disease were identified from MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and references of identified articles and relevant reviews. Primary outcomes were postoperative complications, mortality, and reoperation. Secondary outcomes were operative time, postoperative pain, postoperative hospital stay, nasogastric tube duration, and time to resume diet. Statistical analysis was carried out by Review Manage software. Five RCTs investigating a total of 549 patients, of whom, 279 received laparoscopic repair and 270 received open repair, were included in the final analysis. There were no significant differences between these two procedures in some primary outcomes including overal postoperative complication rate, mortality, and reoperation rate. Subcategory analysis of postoperative complications showed that laparoscopic repair had also similar rates of repair site leakage, intra-abdominal abscess, postoperative ileus, pneumonia, and urinary tract infection as open surgery, except of the lower surgical site infection rate (P < 0.05). In addition, there were also no significant differences between these two procedures in some second outcomes including operative time, postoperative hospital stay, and time to resume diet, but laparoscopic repair had shorter nasogastric tube duration (P < 0.05) and less postoperative pain (P < 0.05) than open surgery. Laparoscopic surgery is comparable with open surgery in the setting of repair for perforated peptic ulcer. The obvious advantages of laparoscopic surgery are the lower surgical site infection rate, shorter nasogastric tube duration and less postoperative pain. However, more higher quality studies should be

  6. Effect of glaucoma tube shunt parameters on cornea endothelial cells in patients with Ahmed valve implants.

    PubMed

    Koo, Euna B; Hou, Jing; Han, Ying; Keenan, Jeremy D; Stamper, Robert L; Jeng, Bennie H

    2015-01-01

    The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves. Thirty-nine eyes of 33 patients with previous superotemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea. The mean age of the operated patients was 58 ± 22 years, and the mean time since glaucoma surgery was 2.5 ± 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss. Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.

  7. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens inserter/remover. 886.5420 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter/remover is a handheld device intended to insert or remove...

  8. Insert metering plates for gas turbine nozzles

    DOEpatents

    Burdgick, Steven S.; Itzel, Gary; Chopra, Sanjay; Abuaf, Nesim; Correia, Victor H.

    2004-05-11

    The invention comprises a metering plate which is assembled to an impingement insert for use in the nozzle of a gas turbine. The metering plate can have one or more metering holes and is used to balance the cooling flow within the nozzle. A metering plate with multiple holes reduces static pressure variations which result from the cooling airflow through the metering plate. The metering plate can be assembled to the insert before or after the insert is inserted into the nozzle.

  9. Heat tube device

    NASA Technical Reports Server (NTRS)

    Khattar, Mukesh K. (Inventor)

    1990-01-01

    The present invention discloses a heat tube device through which a working fluid can be circulated to transfer heat to air in a conventional air conditioning system. The heat tube device is disposable about a conventional cooling coil of the air conditioning system and includes a plurality of substantially U-shaped tubes connected to a support structure. The support structure includes members for allowing the heat tube device to be readily positioned about the cooling coil. An actuatable adjustment device is connected to the U-shaped tubes for allowing, upon actuation thereof, for the heat tubes to be simultaneously rotated relative to the cooling coil for allowing the heat transfer from the heat tube device to air in the air conditioning system to be selectively varied.

  10. Pulse tube cooler having 1/4 wavelength resonator tube instead of reservoir

    NASA Technical Reports Server (NTRS)

    Gedeon, David R. (Inventor)

    2008-01-01

    An improved pulse tube cooler having a resonator tube connected in place of a compliance volume or reservoir. The resonator tube has a length substantially equal to an integer multiple of 1/4 wavelength of an acoustic wave in the working gas within the resonator tube at its operating frequency, temperature and pressure. Preferably, the resonator tube is formed integrally with the inertance tube as a single, integral tube with a length approximately 1/2 of that wavelength. Also preferably, the integral tube is spaced outwardly from and coiled around the connection of the regenerator to the pulse tube at a cold region of the cooler and the turns of the coil are thermally bonded together to improve heat conduction through the coil.

  11. Microendoscopy of the eustachian tube and the middle ear

    NASA Astrophysics Data System (ADS)

    Hopf, Juergen U. G.; Linnarz, Marietta; Gundlach, Peter; Scherer, Hans H.; Lutze-Koffroth, C.; Loerke, S.; Voege, Karl H.; Tschepe, Johannes; Mueller, Gerhard J.

    1992-08-01

    Progressive miniaturization of flexible fiberoptic instruments has made it possible to perform atraumatic endoscopy of the Eustachian tube and tympanic cavity with an intact ear drum. By means of a special set of carrier- and balloon-catheters which are partly actively steerable, flexible microendoscopes with outside diameters of 290 - 700 micrometers are inserted through the nasal cavity into the nasopharyngeal opening of the Eustachian tube and carefully advanced into the middle ear compartment under permanent direct visual control. Second generation microendoscopes with outside diameters of 750 to 1000 micrometers are equipped with a one- direction tip-steering mechanism which allows deflection up to 90 degrees. In addition to it, the use of two special types of four-function scopes (outside diameter: 1.6 mm and 1.8 mm) fitted with a one-lumen working channel are presented. This new technique of `Transnasal Tubo-Tympanoscopy' (TTT) only needs local anesthesia, normally is performed on an outpatient basis, and is indicated for the diagnosis of any disturbances of the sound conducting apparatus (ear drum and ossicular chain) like chronic otitis media and oto-sclerosis and of those sensorineural hearing disorders on which -- until today -- only the traditional surgical tympanoscopy could provide morphological information on the pathogenesis of the hearing loss, e.g., on assumed round window ruptures. By this minimal invasive and minimal traumatizing method pathological alterations of the ossicular chain as well as obstructions in the cartilaginous and the osseous part of the Eustachian tube can be directly visualized.

  12. The impact of HPV status on weight loss and feeding tube use in oropharyngeal carcinoma.

    PubMed

    Vangelov, Belinda; Kotevski, Damian P; Williams, Janet R; Smee, Robert I

    2018-04-01

    It has been well established that patients with oropharyngeal carcinoma are at high nutritional risk, with significant weight loss and tube feeding common. Human papillomavirus (HPV)-associated disease has led to a change in the "typical" presentation and nutritional profile of this population. The aim of our study was to determine whether the need for a feeding tube, and weight loss during radiotherapy (RT) in patients with oropharyngeal carcinoma differed with HPV status. Patients who received curative RT ± chemotherapy from January 2011 to January 2016 were included (n = 100). We retrospectively evaluated feeding tube use and timing of insertion (prophylactic vs reactive), percentage weight loss during RT and the prevalence of critical weight loss (CWL) ≥5%. HPV-positive patients had significantly higher weight loss during RT compared to the rest of the cohort (8.4% vs 6.1%, 95%CI 0.8-3.9, p = 0.003). CWL was observed in 86% and in a higher proportion with HPV-positive disease (93%, p = 0.011). Conditional probability modelling analysis revealed, with 74% accuracy, concurrent chemoradiotherapy and HPV-positive status were predictors of CWL when comparing HPV-positive patients to HPV-negative (96%, p = 0.001 and 98%, p = 0.012 respectively). More HPV-positive patients required feeding tubes (n = 43, 63%, p = 0.05), most being reactive (n = 27, 63%). All patients with reactive tubes experienced CWL. The high incidence of CWL in patients with HPV-positive oropharyngeal carcinoma is of concern. Tube feeding continues to be a necessary nutritional intervention in this population and predicting who will require a tube is challenging. Larger, prospective cohort studies are required. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Endoscopic biliary stent insertion through specialized duodenal stent for combined malignant biliary and duodenal obstruction facilitated by stent or PTBD guidance.

    PubMed

    Lee, Jong Jin; Hyun, Jong Jin; Choe, Jung Wan; Lee, Dong-Won; Kim, Seung Young; Jung, Sung Woo; Jung, Young Kul; Koo, Ja Seol; Yim, Hyung Joon; Lee, Sang Woo

    2017-11-01

    Endoscopic stenting for combined malignant biliary and duodenal obstruction is technically demanding. However, this procedure can be facilitated when there is guidance from previously inserted stent or PTBD tube. This study aimed to evaluate the feasibility and clinical success rate of endoscopic placement of biliary self-expandable metal stent (SEMS) through duodenal SEMS in patients with combined biliary and duodenal obstruction due to inoperable or metastatic periampullary malignancy. A total of 12 patients with combined malignant biliary and duodenal stricture underwent insertion of biliary SEMS through the mesh of specialized duodenal SEMS from July 2012 to October 2016. Technical and clinical success rate, adverse events and survival after completion of SEMS insertion were evaluated. The duodenal strictures were located in the first portion of the duodenum in four patients (Type I), in the second portion in three patients (Type II), and in the third portion in five patients (Type III). Technical success rate of combined metallic stenting was 91.7%. Insertion of biliary SEMS was guided by previously inserted biliary SEMS in nine patients, plastic stent in one patient, and PTBD in two patients. Clinical success rate was 90.9%. There were no early adverse events after the procedure. Mean survival period after combined metallic stenting was 91.9 days (range: 15-245 days). Endoscopic placement of biliary SEMS through duodenal SEMS is feasible with high success rates and relatively easy when there is guidance. This method can be a good alternative for palliation in patients with combined biliary and duodenal obstruction.

  14. Concentric micro-nebulizer for direct sample insertion

    DOEpatents

    Fassel, V.A.; Rice, G.W.; Lawrence, K.E.

    1984-03-06

    A concentric micro-nebulizer and method for introducing liquid samples into a plasma established in a plasma torch including a first tube connected to a source of plasma gas. The concentric micro-nebulizer has inner and outer concentric tubes extending upwardly within the torch for connection to a source of nebulizer gas and to a source of liquid solvent and to a source of sample liquid. The inner tube is connected to the source of liquid solvent and to the source of sample liquid and the outer tube is connected to the source of nebulizer gas. The outer tube has an orifice positioned slightly below the plasma when it is established, with the inner and outer tubes forming an annulus therebetween with the annular spacing between the tubes at said orifice being less than about 0.05mm. The dead volume of the inner tube is less than about 5 microliters.

  15. Concentric micro-nebulizer for direct sample insertion

    DOEpatents

    Fassel, Velmer A.; Rice, Gary W.; Lawrence, Kimberly E.

    1986-03-11

    A concentric micro-nebulizer and method for introducing liquid samples into a plasma established in a plasma torch including a first tube connected to a source of plasma gas. The concentric micro-nebulizer has inner and outer concentric tubes extending upwardly within the torch for connection to a source of nebulizer gas and to a source of liquid solvent and to a source of sample liquid. The inner tube is connected to the source of liquid solvent and to the source of sample liquid and the outer tube is connected to the source of nebulizer gas. The outer tube has an orifice positioned slightly below the plasma when it is established, with the inner and outer tubes forming an annulus therebetween with the annular spacing between the tubes at said orifice being less than about 0.05 mm. The dead volume of the inner tube is less than about 5 microliters.

  16. Improvement of pump tubes for gas guns and shock tube drivers

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.

    1990-01-01

    In a pump tube, a gas is mechanically compressed, producing very high pressures and sound speeds. The intensely heated gas produced in such a tube can be used to drive light gas guns and shock tubes. Three concepts are presented that have the potential to allow substantial reductions in the size and mass of the pump tube to be achieved. The first concept involves the use of one or more diaphragms in the pump tube, thus replacing a single compression process by multiple, successive compressions. The second concept involves a radical reduction in the length-to-diameter ratio of the pump tube and the pump tube piston. The third concept involves shock heating of the working gas by high explosives in a cyclindrical geometry reusable device. Preliminary design analyses are performed on all three concepts and they appear to be quite feasible. Reductions in the length and mass of the pump tube by factors up to about 11 and about 7, respectively, are predicted, relative to a benchmark conventional pump tube.

  17. A simple customized surgical guide for orthodontic miniplates with tube.

    PubMed

    Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2012-09-01

    This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.

  18. Nursing administration of medication via enteral tubes in adults: a systematic review.

    PubMed

    Phillips, Nicole M; Nay, Rhonda

    Enteral tubes are frequently inserted as part of medical treatment in a wide range of patient situations. Patients with an enteral tube are cared for by nurses in a variety of settings, including general and specialised acute care areas, aged care facilities and at home. Regardless of the setting, nurses have the primary responsibility for administering medication through enteral tubes. Medication administration via an enteral tube is a reasonably common nursing intervention that entails a number of skills, including preparing the medication, verifying the tube position, flushing the tube and assessing for potential complications. If medications are not given effectively through an enteral tube, harmful consequences may result leading to increased morbidity, for example, tube occlusion, diarrhoea and aspiration pneumonia. There are resultant costs for the health-care system related to possible increased length of stay and increased use of equipment. Presently what is considered to be best practice to give medications through enteral tubes is unknown. The objective of this systematic review was to determine the best available evidence on which nursing interventions are effective in minimising the complications associated with the administration of medications via enteral tubes in adults. Nursing interventions and considerations related to medication administration included form of medication, verifying tube placement before administration, methods used to give medication, methods used to flush tubes, maintenance of tube patency and specific practices to prevent possible complications related to the administration of enteral medications. The following databases were searched for literature reported in English only: CINAHL, MEDLINE, The Cochrane Library, Current Contents/All Editions, EMBASE, Australasian Medical Index and PsychINFO. There was no date restriction applied. In addition, the reference lists of all included studies were scrutinised for other potentially

  19. Nursing administration of medication via enteral tubes in adults: a systematic review.

    PubMed

    Phillips, Nicole M; Nay, Rhonda

    2007-09-01

    Background  Enteral tubes are frequently inserted as part of medical treatment in a wide range of patient situations. Patients with an enteral tube are cared for by nurses in a variety of settings, including general and specialised acute care areas, aged care facilities and at home. Regardless of the setting, nurses have the primary responsibility for administering medication through enteral tubes. Medication administration via an enteral tube is a reasonably common nursing intervention that entails a number of skills, including preparing the medication, verifying the tube position, flushing the tube and assessing for potential complications. If medications are not given effectively through an enteral tube, harmful consequences may result leading to increased morbidity, for example, tube occlusion, diarrhoea and aspiration pneumonia. There are resultant costs for the health-care system related to possible increased length of stay and increased use of equipment. Presently what is considered to be best practice to give medications through enteral tubes is unknown. Objectives  The objective of this systematic review was to determine the best available evidence on which nursing interventions are effective in minimising the complications associated with the administration of medications via enteral tubes in adults. Nursing interventions and considerations related to medication administration included form of medication, verifying tube placement before administration, methods used to give medication, methods used to flush tubes, maintenance of tube patency and specific practices to prevent possible complications related to the administration of enteral medications. Search strategy  The following databases were searched for literature reported in English only: CINAHL, MEDLINE, The Cochrane Library, Current Contents/All Editions, EMBASE, Australasian Medical Index and PsychINFO. There was no date restriction applied. In addition, the reference lists of all included

  20. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    PubMed

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  1. Field errors in hybrid insertion devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  2. Facile detection of Troponin I using dendritic platinum nanoparticles and capillary tube indicators.

    PubMed

    Lee, Sanghee; Kwon, Donghoon; Yim, Changyong; Jeon, Sangmin

    2015-01-01

    A facile method was developed for the detection of Troponin I (TnI) using dendritic platinum nanoparticles and capillary tube indicators. Dendritic platinum nanoparticles were functionalized with TnI antibodies, which were used to capture TnI in human serum. The captured TnI was conjugated to the inner surface of a glass vial, to which a hydrogen peroxide (H2O2) solution was added. After the glass vial was sealed with a screw cap containing a silicon septum, a capillary tube containing a drop of ink was inserted through the septum. The catalytic dissociation of H2O2 to water and oxygen increased the pressure inside the glass vial and raised the ink level in the capillary tube. The ink level increased with the platinum nanoparticle concentration, which is proportional to the TnI concentration. The sensitivity of this assay for TnI in human serum after a 5 min dissociation reaction, detected with the naked eye, was 0.1 ng/mL, which was better than the sensitivity of the conventional colorimetric method using the TMB oxidation reaction under the same experimental conditions. A control experiment using alpha-fetoprotein, interleukin-5, and C-reactive protein revealed that the developed method was highly selective for the detection of TnI.

  3. Tube thoracostomy; chest tube implantation and follow up

    PubMed Central

    Kuhajda, Ivan; Zarogoulidis, Konstantinos; Kougioumtzi, Ioanna; Huang, Haidong; Li, Qiang; Dryllis, Georgios; Kioumis, Ioannis; Pitsiou, Georgia; Machairiotis, Nikolaos; Katsikogiannis, Nikolaos; Papaiwannou, Antonis; Lampaki, Sofia; Papaiwannou, Antonis; Zaric, Bojan; Branislav, Perin; Porpodis, Konstantinos

    2014-01-01

    Pneumothorax is an urgent medical situation that requires urgent treatment. We can divide this entity based on the etiology to primary and secondary. Chest tube implantation can be performed either in the upper chest wall or lower. Both thoracic surgeons and pulmonary physicians can place a chest tube with minimal invasive techniques. In our current work, we will demonstrate chest tube implantation to locations, methodology and tools. PMID:25337405

  4. Social media and the intrauterine device: a YouTube content analysis.

    PubMed

    Nguyen, Brian T; Allen, Allison J

    2018-01-01

    YouTube's online archive of video testimonials related to health information are more commonly viewed than those developed by clinicians and professional groups, suggesting the importance of the patient experience to viewers. We specifically sought to examine the accuracy of information on, and projected acceptability of, the intrauterine device (IUD) from these YouTube testimonials. We searched YouTube for videos about individual uploaders' IUD experiences, using the search terms 'intrauterine device', 'IUD', 'Mirena' and 'Paragard'. Given interest in user testimonials, we excluded professional and instructional videos belonging to commercial or non-profit entities. Two reviewers independently analysed the videos using a structured guide, with attention to inaccurate information. Of 86 identified videos, four videos featured clinicians and were excluded; 62 met inclusion criteria. Interrater agreement on IUD portrayal was good (K=0.73). Young (mean age 25, range 19-38, years), white (75%), nulliparous (61%) women primarily uploaded content. Most described placement of the LNG-IUS (65%), were posted within 1 month of insertion (45%), and mentioned side effects (66%) - bleeding, pain, and partner sensation of the strings. About one-third of videos contained inaccurate information (34%) and were thought to project an overall negative experience (30%). Videos portraying IUDs negatively were associated with inaccurate information and/or mention of side effects. While one-third of IUD user testimonials on YouTube contained inaccurate information, the majority of IUD experiences were perceived by our study viewers to be positive. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. YouTube and the single-rod contraceptive implant: a content analysis.

    PubMed

    Paul, Jennifer; Boraas, Christy M; Duvet, Mildred; Chang, Judy C

    2017-07-01

    Since the internet has become an important source of contraceptive information with YouTube.com as the second most visited site, we analysed contraceptive implant YouTube videos for content and clinical accuracy. Using the terms 'contraceptive implant', 'Nexplanon' and 'Implanon', the top 20 results on YouTube by relevance and view count were identified. After excluding duplicates, single-rod implant videos in English were included. Videos were classified as providing a professional or patient perspective. Views, duration and comments were noted. Videos were rated for reliability, global quality scale and whether they were positive or negative about the implant. Inter-rater agreement was measured. A total of 120 videos were retrieved; 52 were eligible for review. Less than 23% were professional videos; the majority reported patient experience (46% testimonials, 27% real-time procedure videos, 4% other). Patient videos had been posted a significantly longer duration of time than professional videos (364 vs 188 days, p =0.02), were less reliable ( p ≤0.0001) and were of lower global quality ( p <0.0001). Some 61% of implant testimonial videos were rated as 'positive experiences' and inter-rater agreement was very good (κ=0.81). All testimonials mentioned side effects, commonly irregular bleeding and discomfort with insertion. A minority (26%) reported misinformation. This study found that most of the information on YouTube pertaining to contraceptive implants is accurate, is presented from the patient's perspective, and promotes the method's use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. AtCSLA7, a Cellulose Synthase-Like Putative Glycosyltransferase, Is Important for Pollen Tube Growth and Embryogenesis in Arabidopsis1

    PubMed Central

    Goubet, Florence; Misrahi, Audrey; Park, Soon Ki; Zhang, Zhinong; Twell, David; Dupree, Paul

    2003-01-01

    The cellulose synthase-like proteins are a large family of proteins in plants thought to be processive polysaccharide β-glycosyltransferases. We have characterized an Arabidopsis mutant with a transposon insertion in the gene encoding AtCSLA7 of the CSLA subfamily. Analysis of the transmission efficiency of the insertion indicated that AtCSLA7 is important for pollen tube growth. Moreover, the homozygous insertion was embryo lethal. A detailed analysis of seed developmental progression revealed that mutant embryos developed more slowly than wild-type siblings. The mutant embryos also showed abnormal cell patterning and they arrested at a globular stage. The defective embryonic development was associated with reduced proliferation and failed cellularization of the endosperm. AtCSLA7 is widely expressed, and is likely to be required for synthesis of a cell wall polysaccharide found throughout the plant. Our results suggest that this polysaccharide is essential for cell wall structure or for signaling during plant embryo development. PMID:12586879

  7. Telescoping tube assembly

    NASA Technical Reports Server (NTRS)

    Sturm, Albert J. (Inventor); Marrinan, Thomas E. (Inventor)

    1995-01-01

    An extensible and retractable telescoping tube positions test devices that inspect large stationary objects. The tube has three dimensional adjustment capabilities and is vertically suspended from a frame. The tube sections are independently supported with each section comprising U-shaped housing secured to a thicker support plate. Guide mechanisms preferably mounted only to the thicker plates guide each tube section parallel to a reference axis with improved accuracy so that the position of the remote end of the telescoping tube is precisely known.

  8. Bender/Coiler for Tubing

    NASA Technical Reports Server (NTRS)

    Stoltzfus, J. M.

    1983-01-01

    Easy-to-use tool makes coils of tubing. Tubing to be bend clamped with stop post. Die positioned snugly against tubing. Operator turns handle to slide die along tubing, pushing tubing into spiral groove on mandrel.

  9. Insertion of coherence requests for debugging a multiprocessor

    DOEpatents

    Blumrich, Matthias A.; Salapura, Valentina

    2010-02-23

    A method and system are disclosed to insert coherence events in a multiprocessor computer system, and to present those coherence events to the processors of the multiprocessor computer system for analysis and debugging purposes. The coherence events are inserted in the computer system by adding one or more special insert registers. By writing into the insert registers, coherence events are inserted in the multiprocessor system as if they were generated by the normal coherence protocol. Once these coherence events are processed, the processing of coherence events can continue in the normal operation mode.

  10. Investigation on the Inertance Tubes of Pulse Tube Cryocooler Without Reservoir

    NASA Astrophysics Data System (ADS)

    Liu, Y. J.; Yang, L. W.; Liang, J. T.; Hong, G. T.

    2010-04-01

    Phase angle is of vital importance for high-efficiency pulse tube cryocoolers (PTCs). Inertance tube as the main phase shifter is useful for the PTCs to obtain appropriate phase angle. Experiments of inertance tube without reservoir under variable frequency, variable length and diameter of inertance tube and variable pressure amplitude are investigated respectively. In addition, the authors used DeltaEC, a computer program to predict the performance of low-amplitude thermoacoustic engines, to simulate the effects of inertance tube without reservoir. According to the comparison of experiments and theoretical simulations, DeltaEC method is feasible and effective to direct and improve the design of inertance tubes.

  11. Kaumana lava tube

    NASA Technical Reports Server (NTRS)

    Greeley, R.

    1974-01-01

    The entrance to Kaumana Lava Tube is in a picnic ground next to Highway 20 (Kaumana Drive) about 6.5 km southwest of Hilo. The area is passed on the way to the Kona Coast via the Saddle Road and is identified by a Hawaii Visitors Bureau sign. Although it is not the largest lava tube in the islands, Kaumana Lava Tube is an interesting geological formation, displaying many of the features typical of lava tube interiors. It is accessible, relatively easy to walk through, and is in an excellent state of preservation. The tube developed in a historic lava flow (1881, from Mauna Loa), and many aspects of lava tube activity are observed.

  12. Multiple tube premixing device

    DOEpatents

    Uhm, Jong Ho; Naidu, Balachandar; Ziminksy, Willy Steve; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin; Stevenson, Christian; Felling, David

    2013-08-13

    The present application provides a premixer for a combustor. The premixer may include a fuel plenum with a number of fuel tubes and a burner tube with a number of air tubes. The fuel tubes extend about the air tubes.

  13. Multiple tube premixing device

    DOEpatents

    Uhm, Jong Ho; Varatharajan, Balachandar; Ziminsky, Willy Steve; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin; Stevenson, Christian; Felling, David

    2012-12-11

    The present application provides a premixer for a combustor. The premixer may include a fuel plenum with a number of fuel tubes and a burner tube with a number of air tubes. The fuel tubes extend about the air tubes.

  14. Retrovirus Studies in Nonhuman Primates at Four Regional Primate Research Centers.

    DTIC Science & Technology

    1990-09-30

    inoculation of the vaginal mucosa with SIV-infected splenocytes. The Heterosexual Transmission of AIDS: A Simian Model. The overall objective of this...rhesus macaques. We have previously reported that SIV can be transmitted across the vaginal mucosa of female rhesus macaques (Miller, et. al., 1990). To...infused through a 2.5mm outer diameter (8 French) soft, plastic, pediatric nasogastric feeding tube (American Pharmaseal, Valencia, Ca.) into the 3 vaginal

  15. Nozzle cavity impingement/area reduction insert

    DOEpatents

    Yu, Yufeng Phillip; Itzel, Gary Michael; Osgood, Sarah Jane

    2002-01-01

    A turbine vane segment is provided that has inner and outer walls spaced from one another, a vane extending between the inner and outer walls and having leading and trailing edges and pressure and suction sides, the vane including discrete leading edge, intermediate, aft and trailing edge cavities between the leading and trailing edges and extending lengthwise of the vane for flowing a cooling medium; and an insert sleeve within at least one of the cavities and spaced from interior wall surfaces thereof. The insert sleeve has an inlet for flowing the cooling medium into the insert sleeve and has impingement holes defined in first and second walls thereof that respectively face the pressure and suction sides of the vane. The impingement holes of at least one of those first and second walls are defined along substantially only a first, upstream portion thereof, whereby the cooling flow is predominantly impingement cooling along a first region of the insert wall corresponding to the first, upstream portion and the cooling flow is predominantly convective cooling along a second region corresponding to a second, downstream portion of the at least one wall of the insert sleeve.

  16. Peripherally inserted central catheters in the neonatal period.

    PubMed

    Uygun, Ibrahim; Okur, Mehmet Hanifi; Otcu, Selcuk; Ozturk, Hayrettin

    2011-10-01

    Peripherally inserted central catheters (PICC) have been extensively used in neonates. However, insertion of these thinnest catheters is a very delicate procedure associated with a high failure rate. In our Neonatal Surgical Intensive Care Unit, we developed a very easy new PICC insertion and evaluated the neonates treated with PICCs which were inserted by using our technique as well as catheter features such as success rate, number of insertion attempts, reason for removal and complications. Information was retrospectively collected on all 40 PICCs inserted at Kutahya Evliya Celebi Goverment Hospital and Dicle University Hospital during a 6-years period from September 2004 to September 2010. A total of 40 PICCs were inserted in 37 patients (26, 70% males, 11, 30% females) by using new technique. The median age of patients was 8.3 days (range 1 to 66 days) and the median weight of patients was 2365 g (range 600 to 5000 g). The vein most commonly accessed was long saphenous vein (85%). The length of PICCs in the body was 19.6 cm (range 5 cm to 30 cm). The tip was located in a central vein in all patients. Surgical abdomen was the most common cause for PICC insertion (38%). Duration of catheterization was 7.7±5.6 days (1-F 5.5 days, 2-F 8.6 days). Almost all of the PICCs were inserted successfully (40/42, success rate 95%) and in the first venipucture (36/42, 86%). Completion of therapy and removed after death were achieved with 87% of PICCs. Three minor complications were noted. Minor bleeding in the insertion site which was stopped via compression occurred in two neonates. Major complication was not seen. No deaths were directly attributed to PICCs use. The new insertion technique of the neonatal peripherally inserted central catheters may be one of the easiest and safest techniques, in comparison to previous techniques reported in the literature.

  17. Z-2 Threaded Insert Design and Testing Abstract

    NASA Technical Reports Server (NTRS)

    Rhodes, RIchard; Graziosi, Dave; Jones, Bobby; Ferl, Jinny; Scarborough, Steve; Sweeney, Mitch

    2016-01-01

    The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits. The Z-2 is another step in the NASA's technology development roadmap leading to human exploration of the Martian surface. To meet a more challenging set of requirements than previous suit systems standard design features, such as threaded inserts, have been re-analyzed and improved. NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement NASA levied on the suit composites was the ability to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. The design of the interface flanges of the composites allowed some of the inserts to be a "T" style insert that was installed through the entire thickness of the laminate. The flange portion of the insert provides a mechanical lock as a redundancy to the adhesive aiding in the pullout load that the insert can withstand. In some locations it was not possible to utilize at "T" style insert and a blind insert was used instead. These inserts rely completely on the bond strength of the adhesive to resist pullout. It was determined during the design of the suit that the inserts did not need to withstand loads induced from pressure cycling but instead tension induced from torqueing the screws to bolt on hardware which creates a much higher stress on them. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper

  18. Design and evaluation of moxifloxacin hydrochloride ocular inserts.

    PubMed

    Pawar, Pravin K; Katara, Rajesh; Majumdar, Dipak K

    2012-03-01

    The objective of the present investigation was to prepare and evaluate ocular inserts of moxifloxacin. An ocular insert was made from an aqueous dispersion of moxifloxacin, sodium alginate, polyvinyl alcohol, and dibutyl phthalate by the film casting method. The ocular insert (5.5 mm diameter) was cross-linked by CaCl2 and was coated with Eudragit S-100, RL-100, RS-100, E-100 or L-100. The in vitro drug drainage/permeation studies were carried out using an all-glass modified Franz diffusion cell. The drug concentration and mucoadhesion time of the ocular insert were found satisfactory. Cross-linking and coating with polymers extended the drainage from inserts. The cross-linked ocular insert coated with Eudragit RL-100 showed maximum drug permeation compared to other formulations.

  19. Torsion Tests of Tubes

    NASA Technical Reports Server (NTRS)

    Stang, Ambrose H; Ramberg, Walter; Back, Goldie

    1937-01-01

    This report presents the results of tests of 63 chromium-molybdenum steel tubes and 102 17st aluminum-alloy tubes of various sizes and lengths made to study the dependence of the torsional strength on both the dimensions of the tube and the physical properties of the tube material. Three types of failure are found to be important for sizes of tubes frequently used in aircraft construction: (1) failure by plastic shear, in which the tube material reached its yield strength before the critical torque was reached; (2) failure by elastic two-lobe buckling, which depended only on the elastic properties of the tube material and the dimensions of the tube; and (3) failure by a combination of (1) and (2) that is, by buckling taking place after some yielding of the tube material.

  20. Deflation opening pressure of the eustachian tube.

    PubMed

    Cohen, D

    1989-03-01

    Measurements derived from tests of the performance of the eustachian tube (ET) under a variety of normal and pathologic conditions are widely diffuse and overlap considerably. In this survey, the deflation opening pressure (DOP) of the ET was tested in 31 patients suffering either from recurrent otitis (these patients had ventilating tubes inserted) or from chronic otitis media. Oxygen was deflated from the external ear canal, through the middle ear to the pharyngeal end of the ET. The DOP was the pressure needed for the passing of the oxygen. This pressure was usually between 100 to 200 mm H2O. No difference was found in the DOP between infants and adults or between discharging ears and dry ones. A second measurement was obtained through measuring the deflation flow pressure (DFP) required for the continuous passage of oxygen through the ET. The DFP was less than the DOP by approximately 20 to 60 mm H2O, and again no difference was noted between age groups or between infected and noninfected ears. It was concluded that DOP and DFP measurements of the ET are similar in a variety of conditions and therefore cannot indicate whether the ET is normally or abnormally functioning. The existence of a linear connection between the health of the ET and its performance is not proven; hence the role of the ET in predicting the likely outcome of tympanoplasty should be assessed within a different context.

  1. Heat exchanger tube mounts

    DOEpatents

    Wolowodiuk, W.; Anelli, J.; Dawson, B.E.

    1974-01-01

    A heat exchanger in which tubes are secured to a tube sheet by internal bore welding is described. The tubes may be moved into place in preparation for welding with comparatively little trouble. A number of segmented tube support plates are provided which allow a considerable portion of each of the tubes to be moved laterally after the end thereof has been positioned in preparation for internal bore welding to the tube sheet. (auth)

  2. Multi-tube arrangement for combustor and method of making the multi-tube arrangement

    DOEpatents

    Ziminsky, Willy Steve [Simpsonville, SC

    2012-07-31

    A fuel injector tube includes a one piece, unitary, polygonal tube having an inlet end and an outlet end. The fuel injector tube further includes a fuel passage extending from the inlet end to the outlet end along a longitudinal axis of the polygonal tube, a plurality of air passages extending from the inlet end to the outlet end and surrounding the fuel passage, and a plurality of fuel holes. Each fuel hole connects an air passage with the fuel passage. The inlet end of the polygonal tube is formed into a fuel tube. A fuel injector includes a plurality of fuel injector tubes and a plate. The plurality of fuel tubes are connected to the plate adjacent the inlet ends of the plurality of fuel injector tubes.

  3. Nozzle insert for mixed mode fuel injector

    DOEpatents

    Lawrence, Keith E [Peoria, IL

    2006-11-21

    A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by first and second needle valve members. The homogeneous charged nozzle outlet set is defined by a nozzle insert that is attached to an injector body, which defines the conventional nozzle outlet set. The nozzle insert is a one piece metallic component with a large diameter segment separated from a small diameter segment by an annular engagement surface. One of the needle valve members is guided on an outer surface of the nozzle insert, and the nozzle insert has an interference fit attachment to the injector body.

  4. Effect of vibration frequency on biopsy needle insertion force.

    PubMed

    Tan, Lei; Qin, Xuemei; Zhang, Qinhe; Zhang, Hongcai; Dong, Hongjian; Guo, Tuodang; Liu, Guowei

    2017-05-01

    Needle insertion is critical in many clinical medicine procedures, such as biopsy, brachytherapy, and injection therapy. A platform with two degrees of freedom was set up to study the effect of vibration frequency on needle insertion force. The gel phantom deformation at the needle cutting edge and the Voigt model are utilized to develop a dynamic model to explain the relationship between the insertion force and needle-tip velocity. The accuracy of this model was verified by performing needle insertions into phantom gel. The effect of vibration on insertion force can be explained as the vibration increasing the needle-tip velocity and subsequently increasing the insertion force. In a series of needle insertion experiments with different vibration frequencies, the peak forces were selected for comparison to explore the effect of vibration frequency on needle insertion force. The experimental results indicate that the insertion force at 500Hz increases up to 17.9% compared with the force at 50Hz. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. 49 CFR 230.61 - Arch tubes, water bar tubes, circulators and thermic siphons.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Arch tubes, water bar tubes, circulators and... MAINTENANCE STANDARDS Boilers and Appurtenances Washing Boilers § 230.61 Arch tubes, water bar tubes... water bar tubes shall thoroughly be cleaned mechanically, washed, and inspected. Circulators and thermic...

  6. Use of tapered Pyrex capillary tubes to increase the mechanical stability of multiwall carbon nanotubes field emitters

    NASA Astrophysics Data System (ADS)

    Mousa, M. S.; Bani Ali, E. S.; Hagmann, M. J.

    2018-02-01

    In this study, NanocylTM NC 7000 Thin Multiwall Carbon Nanotubes (MWCNTs) were used with a high aspect ratio (>150) made by the process of catalytic chemical vapor deposition (CCVD). The field emitter tips were prepared by inserting these MWCT into fine glass capillary tubes that were pulled at high temperatures and then cut. Measurements were carried out under ultra-high vacuum (UHV) conditions with a base pressure of 10-9 mbar. The data show the effects of initial conditioning of MWCNT and hysteresis. Compression of the MWCNT by the capillary tubes appears to provide adequate mechanical support without requiring the use of a low-melting point electrically-conductive binder as has been used previously. Emission currents in excess of 1 μA were obtained so this technique shows promise as a reliable, stable, powerful electron source.

  7. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay; Ensor, Joe E.

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if themore » absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.« less

  8. Sensing Membrane Stresses by Protein Insertions

    PubMed Central

    Campelo, Felix; Kozlov, Michael M.

    2014-01-01

    Protein domains shallowly inserting into the membrane matrix are ubiquitous in peripheral membrane proteins involved in various processes of intracellular membrane shaping and remodeling. It has been suggested that these domains sense membrane curvature through their preferable binding to strongly curved membranes, the binding mechanism being mediated by lipid packing defects. Here we make an alternative statement that shallow protein insertions are universal sensors of the intra-membrane stresses existing in the region of the insertion embedding rather than sensors of the curvature per se. We substantiate this proposal computationally by considering different independent ways of the membrane stress generation among which some include changes of the membrane curvature whereas others do not alter the membrane shape. Our computations show that the membrane-binding coefficient of shallow protein insertions is determined by the resultant stress independently of the way this stress has been produced. By contrast, consideration of the correlation between the insertion binding and the membrane curvature demonstrates that the binding coefficient either increases or decreases with curvature depending on the factors leading to the curvature generation. To validate our computational model, we treat quantitatively the experimental results on membrane binding by ALPS1 and ALPS2 motifs of ArfGAP1. PMID:24722359

  9. Distal Insertions of the Biceps Femoris

    PubMed Central

    Branch, Eric A.; Anz, Adam W.

    2015-01-01

    Background: Avulsion of the biceps femoris from the fibula and proximal tibia is encountered in clinical practice. While the anatomy of the primary posterolateral corner structures has been qualitatively and quantitatively described, a quantitative analysis regarding the insertions of the biceps femoris on the fibula and proximal tibia is lacking. Purpose: To quantitatively assess the insertions of the biceps femoris, fibular collateral ligament (FCL), and anterolateral ligament (ALL) on the fibula and proximal tibia as well as establish relationships among these structures and to pertinent surgical anatomy. Study Design: Descriptive laboratory study. Methods: Dissections were performed on 12 nonpaired, fresh-frozen cadaveric specimens identifying the biceps femoris, FCL, and ALL, and their insertions on the proximal tibia and fibula. The footprint areas, orientations, and distances from relevant osseous landmarks were measured using a 3-dimensional coordinate measurement device. Results: Dissection produced 6 easily identifiable and reproducible anatomic footprints. Tibial footprints included the insertion of the ALL and an insertion of the biceps femoris (TBF). Fibular footprints included the insertion of the FCL, a distal insertion of the biceps femoris (DBF), a medial footprint of the biceps femoris (MBF), and a proximal footprint of the biceps femoris (PBF). The mean area of these footprints (95% CI) was as follows: ALL, 53.0 mm2 (38.4-67.6); TBF, 93.9 mm2 (72.0-115.8); FCL, 86.8 mm2 (72.3-101.2); DBF, 119 mm2 (91.1-146.9); MBF, 46.8 mm2 (29.0-64.5); and PBF, 215 mm2 (192.4-237.5). The mean distance (95% CI) from the Gerdy tubercle to the center of the ALL footprint was 24.3 mm (21.6-27.0) and to the center of the TBF was 22.5 mm (21.0-24.0). The center of the DBF was 8.68 mm (7.0-10.3) from the anterior border of the fibula, the center of the FCL was 14.6 mm (12.5-16.7) from the anterior border of the fibula and 20.7 mm (19.0-22.4) from the tip of the fibular

  10. Magnetic particles as liquid carriers in the microfluidic lab-in-tube approach to detect phase change.

    PubMed

    Blumenschein, Nicholas A; Han, Daewoo; Caggioni, Marco; Steckl, Andrew J

    2014-06-11

    Magnetic beads (MBs) with ∼1.9 μm average diameter were used to transport specific microliter-scale volumes of liquids between adjacent reservoirs within a closed tube under the influence of a magnetic field. The tube's inner surface is coated with a hydrophobic layer, enabling the formation of a surface tension valve by inserting an air gap between reservoirs. This transfer process was implemented by keeping the MBs stationary with a fixed external magnet while the liquid reservoirs were translated by a computer-controlled syringe pump system. The magnet induces the aggregation of MBs in a loosely packed cluster (void volume ∼90-95%) against the tube's inner wall. The liquid trapped in the MB cluster is transported across the air gap between reservoirs. Fluorescence intensity from a dye placed in one reservoir is used to measure the volume of liquid transferred between reservoirs. The carry-over liquid volume is controlled by the mass of the MBs within the device. The typical volume of liquid carried by the MB cluster is ∼2 to 3 μL/mg of beads, allowing the use of small samples. This technique can be used to study the effect of small compositional variation on the properties of fluid mixtures. The feasibility of this "lab-in-tube" approach for binary phase diagram determination in a water-surfactant (C12E5) system was demonstrated.

  11. Turbine airfoil having near-wall cooling insert

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity towardmore » the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.« less

  12. Gastric emptying of cold beverages in humans: effect of transportable carbohydrates.

    PubMed

    Shi, X; Bartoli, W; Horn, M; Murray, R

    2000-12-01

    Eight healthy subjects, aged 39.0 ¿ 2.4 years, consumed four 6% carbohydrate-electrolyte solutions containing either one (glucose or fructose) or two transportable carbohydrates in single (glucose + fructose) or bound (sucrose) forms. Solution osmolalities ranged from 250 to 434 mOsm/kg H2O. The test solutions were ingested at rest in the amount of 6 ml/kg of body weight at a temperature of 12 ¿C. Gastric emptying rate was measured by repeated aspirations via a nasogastric tube using the modified George double-sampling technique. The intragastric temperature was determined by a temperature probe attached to the nasogastric tube. There were no significant differences in gastric emptying rates and gastric volumes among the solutions. Intragastric temperature dropped from 36.5 ¿C to 23.3 ¿ 3 ¿C immediately after beverage ingestion but recovered to above 30 ¿C within 5 min. These data suggest that the gastric emptying rate of the specified beverages is not affected by the number and type of carbohydrates or by solution osmolalities within the tested range. Within 5 min after ingestion, cold beverages are warmed to above 30 C in the stomach. This infers that the effect of cold solution temperature on gastric emptying rate is likely to be small and transitory.

  13. Gastro-oesophageal reflux in mechanically ventilated patients: effects of an oesophageal balloon.

    PubMed

    Orozco-Levi, M; Félez, M; Martínez-Miralles, E; Solsona, J F; Blanco, M L; Broquetas, J M; Torres, A

    2003-08-01

    Gastro-oesophageal reflux (GOR) and bronchoaspiration of gastric content are risk factors linked with ventilator-associated pneumonia. This study was aimed at evaluating the effect of a nasogastric tube (NGT) incorporating a low-pressure oesophageal balloon on GOR and bronchoaspiration in patients receiving mechanical ventilation. Fourteen patients were studied in a semi-recumbent position for 2 consecutive days. Inflation or deflation of the oesophageal balloon was randomised. Samples of blood, gastric content, and oropharyngeal and bronchial secretions were taken every 2 h over a period of 8 h. A radioactively labelled nutritional solution was continuously administered through the NGT. The magnitude of both the GOR and bronchoaspiration was measured by radioactivity counting of oropharyngeal and bronchial secretion samples, respectively. Inflation of the oesophageal balloon resulted in a significant decrease of both GOR and bronchoaspiration of gastric content. This protective effect was statistically significant from 4 h following inflation throughout the duration of the study. This study demonstrates that an inflated oesophageal balloon delays and decreases gastro-oesophageal and bronchial aspiration of gastric content in patients carrying a nasogastric tube and receiving enteral nutrition during mechanical ventilation. Although the method was found to be safe when applied for 8 h, longer times should be considered with caution.

  14. Reduced-vibration tube array

    DOEpatents

    Bruck, Gerald J.; Bartolomeo, Daniel R.

    2004-07-20

    A reduced-vibration tube array is disclosed. The array includes a plurality of tubes in a fixed arrangement and a plurality of damping members positioned within the tubes. The damping members include contoured interface regions characterized by bracing points that selectively contact the inner surface of an associated tube. Each interface region is sized and shaped in accordance with the associated tube, so that the damping member bracing points are spaced apart a vibration-reducing distance from the associated tube inner surfaces at equilibrium. During operation, mechanical interaction between the bracing points and the tube inner surfaces reduces vibration by a damage-reducing degree. In one embodiment, the interface regions are serpentine shaped. In another embodiment, the interface regions are helical in shape. The interface regions may be simultaneously helical and serpentine in shape. The damping members may be fixed within the associated tubes, and damping member may be customized several interference regions having attributes chosen in accordance with desired flow characteristics and associated tube properties.

  15. Landscape of Insertion Polymorphisms in the Human Genome

    PubMed Central

    Onozawa, Masahiro; Goldberg, Liat; Aplan, Peter D.

    2015-01-01

    Nucleotide substitutions, small (<50 bp) insertions or deletions (indels), and large (>50 bp) deletions are well-known causes of genetic variation within the human genome. We recently reported a previously unrecognized form of polymorphic insertions, termed templated sequence insertion polymorphism (TSIP), in which the inserted sequence was templated from a distant genomic region, and was inserted in the genome through reverse transcription of an RNA intermediate. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; class 1 TSIPs show target site duplication, polyadenylation, and preference for insertion at a 5′-TTTT/A-3′ sequence, suggesting a LINE-1 based insertion mechanism, whereas class 2 TSIPs show features consistent with repair of a DNA double strand break by nonhomologous end joining. To gain a more complete picture of TSIPs throughout the human population, we evaluated whole-genome sequence from 52 individuals, and identified 171 TSIPs. Most individuals had 25–30 TSIPs, and common (present in >20% of individuals) TSIPs were found in individuals throughout the world, whereas rare TSIPs tended to cluster in specific geographic regions. The number of rare TSIPs was greater than the number of common TSIPs, suggesting that TSIP generation is an ongoing process. Intriguingly, mitochondrial sequences were a frequent template for class 2 insertions, used more commonly than any nuclear chromosome. Similar to single nucleotide polymorphisms and indels, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases, and can be useful in tracking historical migration of populations. PMID:25745018

  16. 21 CFR 310.515 - Patient package inserts for estrogens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Patient package inserts for estrogens. 310.515... package inserts for estrogens. (a) Requirement for a patient package insert. FDA concludes that the safe... patient package insert containing information concerning the drug's benefits and risks. An estrogen drug...

  17. Observation of "YouTube" Language Learning Videos ("YouTube" LLVS)

    ERIC Educational Resources Information Center

    Alhamami, Munassir

    2013-01-01

    This paper navigates into the "YouTube" website as one of the most usable online tools to learn languages these days. The paper focuses on two issues in creating "YouTube" language learning videos: pedagogy and technology. After observing the existing "YouTube" LLVs, the study presents a novel rubric that is directed…

  18. Hemothorax caused by the trocar tip of the rod inserter after minimally invasive transforaminal lumbar interbody fusion: case report.

    PubMed

    Maruo, Keishi; Tachibana, Toshiya; Inoue, Shinichi; Arizumi, Fumihiro; Yoshiya, Shinichi

    2016-03-01

    Minimally invasive surgery (MIS) for transforaminal lumbar interbody fusion (MIS-TLIF) is widely used for lumbar degenerative diseases. In the paper the authors report a unique case of a hemothorax caused by the trocar tip of the rod inserter after MIS-TLIF. A 61-year-old woman presented with thigh pain and gait disturbance due to weakness in her lower right extremity. She was diagnosed with a lumbar disc herniation at L1-2 and the MIS-TLIF procedure was performed. Immediately after surgery, the patient's thigh pain resolved and she remained stable with normal vital signs. The next day after surgery, she developed severe anemia and her hemoglobin level decreased to 7.6 g/dl, which required blood transfusions. A chest radiograph revealed a hemothorax. A CT scan confirmed a hematoma of the left paravertebral muscle. A chest tube was placed to treat the hemothorax. After 3 days of drainage, there was no active bleeding. The patient was discharged 14 days after surgery without leg pain or any respiratory problems. This complication may have occurred due to injury of the intercostal artery by the trocar tip of the rod inserter. A hemothorax after spine surgery is a rare complication, especially in the posterior approach. The rod should be caudally inserted in the setting of the thoracolumbar spine.

  19. Cruciate retaining and cruciate substituting ultra-congruent insert

    PubMed Central

    Deledda, Davide; Rosso, Federica; Ratto, Nicola; Bruzzone, Matteo; Bonasia, Davide Edoardo; Rossi, Roberto

    2016-01-01

    The posterior cruciate ligament (PCL) conservation and the polyethylene insert constraint in total knee arthroplasty (TKA) are still debated. The PCL is one of the primary stabilizers of the joint, but cruciate retaining (CR) implants have the disadvantage of a difficult balancing of the PCL. Postero-stabilized (PS) implants were introduced to reduce this problem. However, also the PS implants have some disadvantages, due to the cam-mechanism, such as high risk of cam-mechanism polyethylene wear. To minimize the polyethylene wear of the cam-mechanism and the bone sacrifice due to the intercondylar box, different types of inserts were developed, trying to increase the implant conformity and to reduce stresses on the bone-implant interface. In this scenario ultra-congruent (UC) inserts were developed. Those inserts are characterized by a high anterior wall and a deep-dished plate. This conformation should guarantee a good stability without the posterior cam. Few studies on both kinematic and clinical outcomes of UC inserts are available. Clinical and radiological outcomes, as well as kinematic data are similar between UC mobile bearing (MB) and standard PS MB inserts at short to mid-term follow-up. In this manuscript biomechanics and clinical outcomes of UC inserts will be described, and they will be compared to standard PS or CR inserts. PMID:26855938

  20. Rectal suppository: commonsense and mode of insertion.

    PubMed

    Abd-el-Maeboud, K H; el-Naggar, T; el-Hawi, E M; Mahmoud, S A; Abd-el-Hay, S

    1991-09-28

    Rectal suppository is a well-known form of medication and its use is increasing. The commonest shape is one with an apex (pointed end) tapering to a base (blunt end). Because of a general lack of information about mode of insertion, we asked 360 lay subjects (Egyptians and non-Egyptians) and 260 medical personnel (physicians, pharmacists, and nurses) by questionnaire which end they inserted foremost. Apart from 2 individuals, all subjects suggested insertion with the apex foremost. Commonsense was the most frequent basis for this practice (86.9% of lay subjects and 84.6% of medical personnel) followed by information from a relative, a friend, or medical personnel, or from study at medical school. Suppository insertion with the base or apex foremost was compared in 100 subjects (60 adults, 40 infants and children). Retention with the former method was more easily achieved in 98% of the cases, with no need to introduce a finger in the anal canal (1% vs 83%), and lower expulsion rate (0% vs 3%). The designer of the "torpedo-shaped" suppository suggested its insertion with apex foremost. Our data suggest that a suppository is better inserted with the base foremost. Reversed vermicular contractions or pressure gradient of the anal canal might press it inwards.

  1. Placement of Intubating Laryngeal Mask Airway Is Easier than Placement of Laryngeal Tube during Manual In-Line Stabilisation of The Neck

    PubMed Central

    Komatsu, R.; Nagata, O.; Kamata, K.; Yamagata, K.; Sessler, D.I.; Ozaki, M.

    2005-01-01

    Summary We compared the usefulness of the laryngeal tube (LT) with the intubating laryngeal mask airway (ILMA) in 51 patients whose necks were stabilised by manual in-line traction. After induction of anaesthesia and neuromuscular block, the LT and ILMA were inserted consecutively in a randomised, crossover design. During pressure-controlled ventilation (20 cmH2O inspiratory pressure), we measured insertion attempts, time to establish positive-pressure ventilation, tidal volume, gastric insufflation, and minimum airway pressure at which gas leaked around the cuff. Data were compared using Wilcoxon signed-rank tests; P<0.05 was considered significant. Insertion was more difficult with the LT (successful at first attempt in 16 patients) than with the ILMA (successful at first attempt in 42 patients, P<0.0001). Time required for insertion was longer for the LT (28 [23–35] sec, median [interquartile range]) than the ILMA (20 [15–25] sec, P=0.0009). Tidal volume was less for the LT (440 [290–670] ml) than the ILMA. (630 [440–750] ml, P=0.013). Minimum airway pressure at which gas leak occurred and incidence of gastric insufflation were similar with two devices. In patients whose necks were stabilised with manual in-line traction, insertion of the ILMA was easier and quicker than insertion of the LT and tidal volume was greater with the ILMA than the LT. PMID:15644005

  2. Measurement of the performance of a spiral wound polyimide regenerator in a pulse tube refrigerator

    NASA Technical Reports Server (NTRS)

    Rawlins, Wayne; Timmerhaus, Klaus D.; Radebaugh, Ray; Daney, D. E.

    1991-01-01

    A regenerator for use in a pulse tube refrigerator has been constructed from a polyimide (polypyromellitimide or PPMI) whose small ratio of thermal conductivity to heat capacity make it a good candidate for a regenerator material in cryocoolers. The regenerator was fabricated using 25 micron thick photoresist strips bonded to a 50 micron thick sheet of PPMI. This composite sheet was wound in jelly-roll fashion around a mandrel and inserted into the regenerator housing. The photoresist strips, formed using a photolithographic technique, provided a 25 micron spacing for the axial flow of gas between each layer of PPMI. Ineffectiveness results are presented for this material under actual operating conditions in a pulse tube refrigerator and compared with a numerical model. The numerical model indicated that a polyimide regenerator would perform much better than one constructed of stainless steel screen, but the experimental results showed the opposite behavior. Measured values for the ineffectiveness were 0.003 for the stainless steel screen and 0.017 for the polyimide.

  3. Waveguide Multimode Directional Coupler for Harvesting Harmonic Power from the Output of Traveling-Wave Tube Amplifiers

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Wintucky, Edwin G.

    2017-01-01

    The paper presents the design, fabrication, and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from dissimilar frequency band waveguides, is capable of isolating power at the 2nd harmonic frequency from the fundamental power at the output port of a high power traveling-wave tube amplifier. The major advantage of the MDC is significantly lower insertion loss compared to a diplexer. The presentation slides for the paper that was approved is attached. The tracking number for the paper that was approved is TN 37015.

  4. Extensive scarring induced by chronic intrathecal tubing augmented cord tissue damage and worsened functional recovery after rat spinal cord injury.

    PubMed

    Zhang, Shu-xin; Huang, Fengfa; Gates, Mary; White, Jason; Holmberg, Eric G

    2010-08-30

    Intrathecal infusion has been widely used to directly deliver drugs or neurotrophins to a lesion site following spinal cord injury. Evidence shows that intrathecal infusion is efficient for 7 days but is markedly reduced after 14 days, due to time dependent occlusion. In addition, extensive fibrotic scarring is commonly observed with intrathecal infusion. These anomalies need to be clearly elucidated in histology. In the present study, all adult Long-Evans rats received a 25 mm contusion injury on spinal cord T10 produced using the NYU impactor device. Immediately after injury, catheter tubing with an outer diameter of 0.38 mm was inserted through a small dural opening at L3 into the subdural space with the tubing tip positioned near the injury site. The tubing was connected to an Alzet mini pump, which was filled with saline solution and was placed subcutaneously. Injured rats without tubing served as control. Rats were behaviorally tested for 6 weeks using the BBB locomotor rating scale and histologically assessed for tissue scarring. Six weeks later, we found that the intrathecal tubing caused extensive scarring and inflammation, related to neutrophils, macrophages and plasma cells. The tubing's tip was occluded by scar tissue and inflammatory cells. The scar tissue surrounding the tubing consists of 20-70 layers of fibroblasts and densely compacted collagen fibers, seriously compressing and damaging the cord tissue. BBB scores of rats with intrathecal tubing were significantly lower than control rats (p<0.01) from 2 weeks after injury, implying serious impairment of functional recovery caused by the scarring. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  5. [ACUTE MESENTEROAXIAL GASTRIC VOLVULUS: A REPORT ON ONE CASE

    PubMed

    Díaz, Juan; Martell, Alex; Ramírez, Lisbeth; Ulloa, Delia

    1998-01-01

    Acute gastric volvulus in children is uncommon. This paper reports a case presented in a 14-year-old female whose diagnosis was suspected preoperatively taking into account the Brouchardt triad (vomiting, epigastric pain and inability to pass the nasogastric tube into the stomach). The child underwent laparatomy and the final diagnosis was mesenteroaxial gastric volvulus complicated with gastric perforation. Closure of the perforation and gastropexy were performed and the operative results were satisfactory.

  6. Mechanisms for sodium insertion in carbon materials

    NASA Astrophysics Data System (ADS)

    Stevens, David Andrew

    2000-12-01

    This thesis details the mechanisms for sodium insertion into different carbons using both electrochemical and vapour techniques. Room temperature electrochemical measurements were completed to examine the insertion and removal of sodium from soft (graphitizable) and nanoporous hard (non-graphitizable) carbons prepared by the heat treatment of organic precursors to a range of temperatures. The mechanisms identified from these studies were further investigated through a series of in situ x-ray scattering studies on operating electrochemical cells. The results obtained were then compared with x-ray scattering measurements on carbons after exposure to sodium vapour at 890C. This work is primarily driven by the aluminium industry's need to understand how sodium insertion causes carbon cathode blocks in aluminium reduction cells to swell. The results obtained are also of relevance to the lithium-ion battery field as they help to verify mechanisms proposed in the literature for lithium insertion into carbon hosts. Some carbons were also identified that could accommodate large amounts of sodium, making them attractive candidates for anodes in rechargeable sodium ion batteries. For soft carbons, the results showed that both sodium and lithium insert between approximately parallel carbon layers along the sloping voltage region of the electrochemical curves, increasing the average interlayer spacing. The sodium and lithium capacities decreased with increasing carbon heat treatment temperature. For the soft carbons studied, the sodium capacity was found to be consistently lower than the lithium capacity, implying that some lithium-accessible sites were unavailable for sodium insertion. The electrochemical profiles for the hard carbons also contained capacity along a sloping voltage region and, as with the soft carbons, this was shown to result from the insertion of sodium and lithium between approximately parallel carbon layers. In contrast to the soft carbons, however, the

  7. A model for phase evolution and volume expansion in tube type Nb3Sn conductors

    NASA Astrophysics Data System (ADS)

    Xu, X.; Sumption, M. D.; Collings, E. W.

    2013-12-01

    In this work, an analytic model for phase formation and volume expansion during heat treatment in tube type Nb3Sn strands is presented. Tube type Nb3Sn conductors consist of Nb or Nb-Ta alloy tube with a simple Cu/Sn binary metal insert to form the basic subelement (filament). A number of these elements, each with an outer Cu jacket, are restacked to form a multifilamentary strand. The present tube type conductors, with 4.2 K, 12 T non-Cu critical current density (Jc) in the 2000-2500 A mm-2 range and effective subelement diameters (deff) in the 12-36 μm range, are of interest for a number of applications. During the reaction of typical tube type strands, the Sn-Cu becomes molten and reacts with the Nb tube first to form NbSn2, then Nb6Sn5. At later times in the reaction sequence, all of the NbSn2 and Nb6Sn5 is converted to Nb3Sn. Some of the Nb3Sn is formed by a Nb-Sn reaction and has a fine grain (FG) structure, while some is converted from Nb6Sn5, which results in a coarse grain (CG) region. The fractions of FG and CG A15 are important in determining the final conductor properties. In this work we develop an analytic model to predict the radial extents of the various phases, and in particular the final FG and CG fractions based on the starting Nb, Cu, and Sn amounts in the subelements. The model is then compared to experimental results and seen to give reasonable agreement. By virtue of this model we outline an approach to minimize the CG regions in tube type and PIT strands and maximize the final FG area fractions. Furthermore, the volume change during the various reaction stages was also studied. It is proposed that the Sn content in the Cu-Sn alloy has a crucial influence on the radial expansion.

  8. Recessed impingement insert metering plate for gas turbine nozzles

    DOEpatents

    Itzel, Gary Michael; Burdgick, Steven Sebastian

    2002-01-01

    An impingement insert sleeve is provided that is adapted to be disposed in a coolant cavity defined through a stator vane. The insert has a generally open inlet end and first and second diametrically opposed, perforated side walls. A metering plate having at least one opening defined therethrough for coolant flow is mounted to the side walls to generally transverse a longitudinal axis of the insert, and is disposed downstream from said inlet end. The metering plate improves flow distribution while reducing ballooning stresses within the insert and allowing for a more flexible insert attachment.

  9. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  10. Heat-shrink plastic tubing seals joints in glass tubing

    NASA Technical Reports Server (NTRS)

    Del Duca, B.; Downey, A.

    1968-01-01

    Small units of standard glass apparatus held together by short lengths of transparent heat-shrinkable polyolefin tubing. The tubing is shrunk over glass O-ring type connectors having O-rings but no lubricant.

  11. Strength of inserts in titanium alloy machining

    NASA Astrophysics Data System (ADS)

    Kozlov, V.; Huang, Z.; Zhang, J.

    2016-04-01

    In this paper, a stressed state of a non-worn cutting wedge in a machined titanium alloy (Ti6Al2Mo2Cr) is analyzed. The distribution of contact loads on the face of a cutting tool was obtained experimentally with the use of a ‘split cutting tool’. Calculation of internal stresses in the indexable insert made from cemented carbide (WC8Co) was carried out with the help of ANSYS 14.0 software. Investigations showed that a small thickness of the cutting insert leads to extremely high compressive stresses near the cutting edge, stresses that exceed the ultimate compressive strength of cemented carbide. The face and the base of the insert experience high tensile stresses, which approach the ultimate tensile strength of cemented carbide and increase a probability of cutting insert destruction. If the thickness of the cutting insert is bigger than 5 mm, compressive stresses near the cutting edge decrease, and tensile stresses on the face and base decrease to zero. The dependences of the greatest normal and tangential stresses on thickness of the cutting insert were found. Abbreviation and symbols: m/s - meter per second (cutting speed v); mm/r - millimeter per revolution (feed rate f); MPa - mega Pascal (dimension of specific contact loads and stresses); γ - rake angle of the cutting tool [°] α - clearance angle of the sharp cutting tool [°].

  12. Radiological assessment of placement of the hysteroscopically inserted Essure permanent birth control device.

    PubMed

    Lorente Ramos, R M; Azpeitia Armán, J; Aparicio Rodríguez-Miñón, P; Salazar Arquero, F J; Albillos Merino, J C

    2015-01-01

    Essure is a permanent birth control device that is inserted through the cervix by hysteroscopy. The device is placed in the fallopian tubes, where it causes occlusion by stimulating fibrosis. Patients can be followed up with plain-film X-rays, hysterosalpingography, and ultrasonography, although the devices can also be identified incidentally on CT and MRI. The follow-up of Essure is based on checking the criteria for appropriate positioning and correct functioning (tubal occlusion) and on diagnosing complications. The most common complications are perforation, migration (toward the uterine or peritoneal cavity), and occlusion failure. In hysterosalpingography, vascular intravasation is the most common cause of diagnostic error. Radiologists need to know how to recognize the device on different imaging techniques, how to check that it is correctly placed and functioning, and how to diagnose complications. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  13. Effect of insertion torque on bone screw pullout strength.

    PubMed

    Lawson, K J; Brems, J

    2001-05-01

    The effect of insertion torque on the holding strength of 4.5-mm ASIF/AO cortical bone screws was studied in vitro. Screw holding strength was determined using an Instron materials testing machine (Bristol, United Kingdom) on 55 lamb femora and 30 human tibiocortical bone sections. Holding strength was defined as tensile stress at pullout with rapid loading to construct failure. Different insertion torques were tested, normalizing to the thickness of cortical bone specimen engaged. These represented low, intermediate, high, and thread-damaging insertion torque. All screws inserted with thread-damaging torque and single cortex engaging screws inserted to high torque tightening moments showed diminished holding strength. This loss of strength amounted to 40%-50% less than screws inserted with less torque.

  14. Influence of perforated triple wing vortex generator on a turbulent flow through a circular tube

    NASA Astrophysics Data System (ADS)

    Gautam, Abhishek; Pandey, Lokesh; Singh, Satyendra

    2018-02-01

    Numerous studies has been observed in terms of enhancement of heat transfer by using passive techniques. In present work, a very unique perforated triple wing vortex generator has been used as an insert geometry, with different geometrical parameters of twist ratio (l/D = 2, 3 & 4) and Porosity (P A /T A = 0%, 10%, 20% & 30%). The experimentation has been performed for the wide range of Re (Re), varying between 3200 to 20,600, in order to investigate effect on heat transfer (Nu), friction factor (f) & thermal performance factor (η) in circular tube HEs with respect to different geometrical and flow parameters. Experimentation has been performed in 1.5 m length of test section with 68 mm diameter. Heat flux of 1000 W/m2 has been provided on the test section with the help of variable voltage transformer connected with Nicrome wire coiled heater located on the test section. There is a significant enhancement has been observed in terms of heat enhancement and pressure drop over the smooth tube. The experimental result shows 4.8 times improvement in heat transfer and 1.63 times improvement in thermal performance as compared to smooth tube HE. The statistical correlations have also been presented for Nu, f and η.

  15. Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion.

    PubMed

    Greene, Nathaniel T; Mattingly, Jameson K; Banakis Hartl, Renee M; Tollin, Daniel J; Cass, Stephen P

    2016-12-01

    Cochlear implant (CI) electrode insertion into the round window induces pressure transients in the cochlear fluid comparable to high-intensity sound transients. Many patients receiving a CI have some remaining functional hearing at low frequencies; thus, devices and surgical techniques have been developed to use this residual hearing. To maintain functional acoustic hearing, it is important to retain function of any hair cells and auditory nerve fibers innervating the basilar membrane; however, in a subset of patients, residual low-frequency hearing is lost after CI insertion. Here, we test the hypothesis that transient intracochlear pressure spikes are generated during CI electrode insertion, which could cause damage and compromise residual hearing. Human cadaveric temporal bones were prepared with an extended facial recess. Pressures in the scala vestibuli and tympani were measured with fiber-optic pressure sensors inserted into the cochlea near the oval and round windows, whereas CI electrodes (five styles from two manufacturers) were inserted into the cochlea via a round window approach. Pressures in the scala tympani tended to be larger in magnitude than pressures in the scala vestibuli, consistent with electrode insertion into the scala tympani. CI electrode insertion produced a range of pressure transients in the cochlea that could occur alone or as part of a train of spikes with equivalent peak sound pressure levels in excess of 170 dB sound pressure level. Instances of pressure transients varied with electrode styles. Results suggest electrode design, insertion mechanism, and surgical technique affect the magnitude and rate of intracochlear pressure transients during CI electrode insertion. Pressure transients showed intensities similar to those elicited by high-level sounds and thus could cause damage to the basilar membrane and/or hair cells.

  16. Intracochlear pressure transients during cochlear implant electrode insertion

    PubMed Central

    Greene, Nathaniel T.; Mattingly, Jameson K.; Banakis Hartl, Renee M.; Tollin, Daniel J.; Cass, Stephen P.

    2016-01-01

    Hypothesis Cochlear implant (CI) electrode insertion into the round window induces pressure transients in the cochlear fluid comparable to high intensity sound transients. Background Many patients receiving a CI have some remaining functional hearing at low frequencies, thus devices and surgical techniques have been developed to utilize this residual hearing. To maintain functional acoustic hearing, it is important to retain function of any hair cells and auditory nerve fibers innervating the basilar membrane; however, in a subset of patients, residual low frequency hearing is lost following CI insertion. Here, we test the hypothesis that transient intracochlear pressure spikes are generated during CI electrode insertion, which could cause damage and compromise residual hearing. Methods Human cadaveric temporal bones were prepared with an extended facial recess. Pressures in the scala vestibuli (PSV) and tympani (PST) were measured with fiber-optic pressure sensors inserted into the cochlea near the oval and round windows while CI electrodes (five styles from two manufacturers) were inserted into the cochlea via a round window approach. Results PST tended to be larger in magnitude than PSV, consistent with electrode insertion into the scala tympani. CI electrode insertion produced a range of pressure transients in the cochlea that could occur alone or as part of a train of spikes with equivalent peak sound pressure levels in excess of 170dB SPL. Instances of pressure transients varied with electrode styles. Conclusions Results suggest electrode design, insertion mechanism, and surgical technique affect the magnitude and rate of intracochlear pressure transients during CI electrode insertion. Pressure transients showed intensities similar to those elicited by high level sounds and thus could cause damage to the basilar membrane and/or hair cells. PMID:27753703

  17. Templated sequence insertion polymorphisms in the human genome

    NASA Astrophysics Data System (ADS)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  18. Insertion Loss of Personal Protective Clothing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shull D.J.; Biesel, V.B.; Cunefare, K.A.

    1999-05-13

    'The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested atmore » least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing''s noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'« less

  19. Insertable fluid flow passage bridgepiece and method

    DOEpatents

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  20. Elliptically polarizing adjustable phase insertion device

    DOEpatents

    Carr, Roger

    1995-01-01

    An insertion device for extracting polarized electromagnetic energy from a beam of particles is disclosed. The insertion device includes four linear arrays of magnets which are aligned with the particle beam. The magnetic field strength to which the particles are subjected is adjusted by altering the relative alignment of the arrays in a direction parallel to that of the particle beam. Both the energy and polarization of the extracted energy may be varied by moving the relevant arrays parallel to the beam direction. The present invention requires a substantially simpler and more economical superstructure than insertion devices in which the magnetic field strength is altered by changing the gap between arrays of magnets.