Sample records for nasogastric tube placement

  1. Confirming nasogastric tube placement: Is the colorimeter as sensitive and specific as X-ray? A diagnostic accuracy study.

    PubMed

    Mordiffi, Siti Zubaidah; Goh, Mien Li; Phua, Jason; Chan, Yiong-Huak

    2016-09-01

    The effect of delivering enteral nutrition or medications via a nasogastric tube that is inadvertently located in the tracheobronchial tract can cause respiratory complications. Although radiographic examination is accepted as the gold standard for confirming the position of patients' enteral tubes, it is costly, involves risks of radiation, and is not failsafe. Studies using carbon dioxide sensors to detect inadvertent nasogastric tube placements have been conducted in intensive care settings. However, none involved patients in general wards. The objective of this study was to ascertain the diagnostic measure of colorimeter, with radiographic examination as the reference standard, to confirm the location of nasogastric tubes in patients. A prospective observational study of a diagnostic test. This study was conducted in the general wards of an approximately 1100-bed acute care tertiary hospital of an Academic Medical Center in Singapore. Adult patients with nasogastric tubes admitted to the general wards were recruited into the study. The colorimeter was attached to the nasogastric tube to detect for the presence of carbon dioxide, suggestive of a tracheobronchial placement. The exact location of the nasogastric tube was subsequently confirmed by a radiographic examination. A total of 192 tests were undertaken. The colorimeter detected carbon dioxide in 29 tested nasogastric tubes, of which radiographic examination confirmed that four tubes were located in the tracheobronchial tract. The colorimeter failed to detect carbon dioxide in one nasogastric tube that was located in the tracheobronchial tract, thus, demonstrating a sensitivity of 0.80 [95% CI (0.376, 0.964)]. The colorimeter detected absence of carbon dioxide in 163 tested nasogastric tubes in which radiographic examination confirmed 160 gastrointestinal and one tracheobronchial placements, demonstrating a specificity of 0.865 [95% CI (0.808, 0.907)]. The colorimeter detected one tracheobronchial

  2. Development of a clinical practice guideline for testing nasogastric tube placement.

    PubMed

    Peter, Sue; Gill, Fenella

    2009-01-01

    A Perth metropolitan hospital group standardized changes to nasogastric tube placement, including removal of the "whoosh test" and litmus paper, and introduction of pH testing. Two audits were conducted: bedside data collection at a pediatric hospital and a point-prevalence audit across seven hospitals. Aspirate was obtained for 97% of all tests and pH was < or = 5.5 for 84%, validating the practice changes. However, patients on continuous feeds and/or receiving acid-inhibiting medications had multiple pH testing fails. Nasogastric tube placement continues to present a challenge for those high-risk patients on continuous feeds and/or receiving acid-inhibiting medications.

  3. A virtual reality based simulator for learning nasogastric tube placement.

    PubMed

    Choi, Kup-Sze; He, Xuejian; Chiang, Vico Chung-Lim; Deng, Zhaohong

    2015-02-01

    Nasogastric tube (NGT) placement is a common clinical procedure where a plastic tube is inserted into the stomach through the nostril for feeding or drainage. However, the placement is a blind process in which the tube may be mistakenly inserted into other locations, leading to unexpected complications or fatal incidents. The placement techniques are conventionally acquired by practising on unrealistic rubber mannequins or on humans. In this paper, a virtual reality based training simulation system is proposed to facilitate the training of NGT placement. It focuses on the simulation of tube insertion and the rendering of the feedback forces with a haptic device. A hybrid force model is developed to compute the forces analytically or numerically under different conditions, including the situations when the patient is swallowing or when the tube is buckled at the nostril. To ensure real-time interactive simulations, an offline simulation approach is adopted to obtain the relationship between the insertion depth and insertion force using a non-linear finite element method. The offline dataset is then used to generate real-time feedback forces by interpolation. The virtual training process is logged quantitatively with metrics that can be used for assessing objective performance and tracking progress. The system has been evaluated by nursing professionals. They found that the haptic feeling produced by the simulated forces is similar to their experience during real NGT insertion. The proposed system provides a new educational tool to enhance conventional training in NGT placement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Determination of a practical pH cutoff level for reliable confirmation of nasogastric tube placement.

    PubMed

    Gilbertson, Heather Ruth; Rogers, Elizabeth Jessie; Ukoumunne, Obioha Chukwunyere

    2011-07-01

    Enteral feeding is a common method of nutrition support when oral intake is inadequate. Confirmation of correct nasogastric (NG) tube placement is essential. Risks of morbidity/mortality associated with misplacement in the lung are well documented. Studies indicate that pH ≤ 4 confirms gastric aspirate, but in pediatrics, a pH of gastric aspirate is often >4. The goal of this study was to determine a reliable and practical pH value to confirm NG tube placement, without increasing the risk of not identifying a misplaced NG tube. Pediatric inpatients older than 4 weeks receiving enteral nutrition (nasogastric or gastrostomy) were recruited over 9 months. Aspirate samples were pH tested at NG tube placement and before feedings. If pH >4, NG tube position was confirmed by chest radiograph or further investigations. In addition, intensive care unit (ICU) patients who required endotracheal suctioning were recruited, and endotracheal aspirate samples were pH tested. A total of 4,330 gastric aspirate samples (96% nasogastric) were collected from 645 patients with a median (interquartile range [IQR]) age of 1.0 years (0.3-5.2 years). The mean (standard deviation [SD]) pH of these gastric samples was 3.6 (1.4) (range, 0-9). pH was >4 in 1,339 (30.9%) gastric aspirate samples, and of these, 244 were radiographed, which identified 10 misplaced tubes (1 with pH 5.5). A total of 65 endotracheal aspirate samples were collected from 19 ICU patients with a median (IQR) age of 0.6 years (0.4-5.2 years). The mean (SD) pH of these samples was 8.4 (0.8) (range, 6-9.5). Given that the lowest pH value of endotracheal aspirate sample was 6, and a misplaced NG tube was identified with pH 5.5, it is proposed that a gastric aspirate pH ≤ 5 is a safer, reliable, and practical cutoff in this population.

  5. Implementation of an electromagnetic imaging system to facilitate nasogastric and post-pyloric feeding tube placement in patients with and without critical illness.

    PubMed

    Windle, E M; Beddow, D; Hall, E; Wright, J; Sundar, N

    2010-02-01

    Artificial nutrition support is required to optimise nutritional status in many patients. Traditional methods of placing feeding tubes may incur clinical risk and financial costs. A technique facilitating placement of nasogastric and post-pyloric tubes via electromagnetic visual guidance may reduce the need for X-ray exposure, endoscopy time and the use of parenteral nutrition. The present study aimed to audit use of such a system at initial implementation in patients within an acute NHS Trust. A retrospective review was undertaken of dietetic and medical records for the first 14 months of using the Cortrak system. Data were collected on referral origin, preparation of the patient prior to insertion, placement success rates and need for X-ray. Cost analysis was also performed. Referrals were received from primary consultants or consultant intensivists, often on the advice of the dietitian. Fifty-nine percent of patients received prokinetic therapy at the time of placement. Thirty-nine tube placements were attempted. Sixty-nine percent of referrals for post-pyloric tube placement resulted in successful placement. X-ray films were requested for 22% of all attempted post-pyloric placements. Less than half of nasogastric tubes were successfully passed, although none of these required X-ray confirmation. The mean cost per tube insertion attempt was 111 pounds. This system confers advantages, particularly in terms of post-pyloric tube placement, even at this early stage of implementation. A reduction in clinical risk and cost avoidance related to X-ray exposure, the need for endoscopic tube placement and parenteral nutrition have been achieved. The implementation of this system should be considered in other centres.

  6. Using a nasogastric tube.

    PubMed

    Candy, C

    1986-09-01

    This discussion of the use of a nasogastric tube covers the equipment needed, the method, rehydration and feeding, prolonged nasogastric feeding, and stopping nasogastric feeding. A nasogastric tube is useful when children are unable to drink safely and in sufficient amounts for any of the following reasons: severe dehydration; if intravenous (IV) therapy is unavailable; low birth weight infants; or the child is drowsy or vomiting. Severely malnourished children may be fed initially in this way if they are too weak or anorexic to eat or drink normally. The following equipment is needed: nasogastric tube; lubricating fluid; a syringe; blue litmus paper, if available; adhesive tape; stethoscope if available; and fluid to be given. Explain to the child's parents and the child, if old enough to understand, what will be done; lie infants flat; measure the approximate length from the child's nostril to the ear lobe and then to the top of the abdomen with the tube and mark the position; clean the nostrils to remove the mucus, and lubricate the tip of the tube and gently insert into the nostril; give the child a drink of water if he or she is conscious; continue to pass the tube down until the position marked reaches the nostril; use the syringe to suck up some fluid and test with blue litmus paper to check that the tube is in the stomach; and inject 5-10 ml of fluid (saline or oral rehydration solution, not milk formula) by syringe if satisfied the tube is in the correct position. Where possible, give a continuous drip of fluid. If this is not possible, give frequent small amounts using the syringe as a funnel. If feeding continues for more than 24 hours, clean the nostrils daily with warm water and change the tube to the other nostril every few days. Also keep the mouth very clean with a dilute solution of 8% sodium bicarbonate, if available, or citrus fruit juice. To remove the tube, remove the adhesive tape, take the tube out gently and smoothly, and offer the child a

  7. Does Bedside Sonography Effectively Identify Nasogastric Tube Placements in Pediatric Critical Care Patients?

    PubMed

    Atalay, Yunus Oktay; Aydin, Ramazan; Ertugrul, Omer; Gul, Selim Baris; Polat, Ahmet Veysel; Paksu, Muhammet Sukru

    2016-12-01

    A nasogastric tube (NGT) insertion is a common procedure in intensive care units, with some serious complications that result from the malposition of the NGT tip. This pilot study was designed to investigate the efficiency of ultrasound in verifying correct NGT placement and to compare these results with radiographic findings. This was a single-center, double-blind prospective study of patients who had received an NGT in the pediatric critical care unit. Twenty-one patients aged 1 month to 18 years were included in this study. All NGTs were inserted by the same critical care physician. After insertion, the physician first confirmed NGT placement by the auscultation of the epigastrium following the insufflation of air. Confirmation was supplemented with an abdominal radiograph. A radiologist who was unaware of the radiographic findings performed bedside sonography on all patients and verified the location of the NGTs. The findings from these 2 physicians were then compared. NGTs were inserted without any complications, and none of the NGTs were positioned in the respiratory tract in any of the patients. All NGT tips were visualized by radiography and sonography with a sensitivity of 100%. Bedside sonography performed by a radiologist is an effective and sensitive diagnostic procedure for confirming the correct NGT position in patients in the pediatric critical care unit.

  8. The nasogastric tube syndrome: two case reports and review of the literature.

    PubMed

    Apostolakis, L W; Funk, G F; Urdaneta, L F; McCulloch, T M; Jeyapalan, M M

    2001-01-01

    The nasogastric tube syndrome is a potentially life-threatening complication of an indwelling nasogastric (NG) tube. The syndrome is thought to result from ulceration and infection of the posterior cricoid region with subsequent dysfunction of vocal cord abduction. This dysfunction may present as complete loss of vocal cord abduction manifested as serious airway compromise. Reports of this syndrome are infrequent, with only 29 cases published to date. Two additional cases of nasogastric tube syndrome diagnosed at the University of Iowa Hospitals and Clinics over a 2-year period are presented. A search of MEDLINE (1966 through February 1999), including review of those articles' references identified seven previous publications, including 29 case reports. These 29 cases are reviewed and the findings summarized. Twenty-nine cases of NG tube syndrome are identified, with 16 of these occurring in the preantibiotic period. Including the two cases presented here, 15 contemporary patients are examined. Among these 15 cases, 10 required tracheostomy, on average 8.5 days after NG tube placement. Although the fully manifested syndrome presents quite dramatically, we suspect that a clinical spectrum of severity exists with less severe cases going unrecognized. Consistent with previous reports, we found that direct visualization of the postcricoid region is required to rule out the diagnosis and recommend such action be taken whenever the diagnosis is suspected. Treatment should include establishment of a safe airway, removal of the tube whenever possible, antibiotic therapy, and antireflux therapy.

  9. Accuracy of biochemical markers for predicting nasogastric tube placement in adults--a systematic review of diagnostic studies.

    PubMed

    Fernandez, Ritin S; Chau, Janita Pak-Chun; Thompson, David R; Griffiths, Rhonda; Lo, Hoi-Shan

    2010-08-01

    The objective of this study was to investigate the diagnostic performance of biochemical tests used to determine placement of nasogastric (NG) tubes after insertion in adults. A systematic review of diagnostic studies was undertaken. A literature search of the bibliographic databases and the World Wide Web was performed to locate original diagnostic studies in English or Chinese on biochemical markers for detecting NG tube location. Studies in which one or more different tests were evaluated with a reference standard, and diagnostic values were reported or could be calculated were included. Two reviewers independently checked all abstracts and full text studies for inclusion criteria. Included studies were assessed for their quality using the QUADAS tool. Study features and diagnostic values were extracted from the included studies. Of the 10 studies included in this review, seven investigated the diagnostic accuracy of pH, one investigated the diagnostic accuracy of pH and bilirubin respectively, two a combination of pH and bilirubin and one a combination of pH, pepsin and trypsin levels in identifying NG tube location. All studies used X-rays as the reference standard for comparison. Pooled results demonstrated that a pH of tubes located in the stomach. However, a pH value of placement demonstrated a sensitivity of 0.89 (95% CI 0.82-0.94) and a specificity of 0.87 (95% CI 0.81-0.93). Bilirubin coupled with pH had a high specificity (0.99) which demonstrated the ability of the test to identify misplaced tubes in intestine. However, the ability of the test to correctly identify gastric placement of feeding tubes was relatively low (sensitivity<0.90). Due to the heterogeneity of the studies and small sample sizes, conclusions about the diagnostic performance of the different tests cannot be drawn. Better designed studies exploring the accuracy of diagnostic tests are needed to improve

  10. Implementation of the evidence review on best practice for confirming the correct placement of nasogastric tube in patients in an acute care hospital.

    PubMed

    Tho, Poh Chi; Mordiffi, Siti; Ang, Emily; Chen, Helen

    2011-03-01

    Nasogastric (NG) tube is a device passed through the gastrointestinal tract of patients for the purpose of feeding, gastric decompression and medication administration. However, a small risk involved in the process is that the tube may be misplaced into the trachea during insertion or may get displaced at a later stage, leading to disastrous results. Recent adverse incidences arising out of the misplacement of NG tube raised concerns among the nursing and medical community and the Patient Safety Officer of the hospital. The Evidence Based Nursing Unit, in collaboration with some of the key nursing leaders in nursing administration, was tasked to explore and institute the current best practice in confirming the correct placement of NG tube. The aim of this project was to institute the best practice to confirm the correct placement of NG tube in patients in an acute care hospital setting. The project comprised of a few stages. The first stage involved reviewing the existing recommendations and guidelines on the methods for checking correct NG tube placement. The second stage involved incorporation of the change of practice into the clinical setting. The final stage was to monitor and evaluate the impact of the new practice on the patients, nurses and other healthcare professionals. Evidence search from guidelines and journals supported the test that used pH indicator instead of the litmus test. There is no evidence that supports the method of auscultation and bubbling to confirm correct NG tube placement in the absence of aspirate. Radiology remains the 'gold standard' for checking correct NG tube placement. The revised method of NG tube placement and workflow was incorporated in the revised Standard Operating Procedures. A total of 17 roadshows were conducted to create awareness regarding the new method amongst the nurses, and the implementation of the revised method and workflow was commenced on 3 November 2008. The initial audit conducted 1 month after the

  11. Limitations of Routine Verification of Nasogastric Tube Insertion Using X-Ray and Auscultation: Two Case Reports of Life-Threatening Complications.

    PubMed

    Nejo, Takahide; Oya, Soichi; Tsukasa, Tsuchiya; Yamaguchi, Naomi; Matsui, Toru

    2016-12-01

    Several bedside approaches used in combination with thoracoabdominal X-ray are widely used to avoid severe complications that have been reported during nasogastric tube management. Although confirmation by X-ray is considered the gold standard, it is not yet perfect. We present 2 cases of rare complications in which the routine verification methods could not detect all the complications related to the nasogastric tube placement. Case 1 was a 17-year-old male who presented with a brain tumor and repeatedly required nasogastric tube placement. Despite normal auscultatory and X-ray findings, the patient's condition deteriorated rapidly after resuming the enteral nutrition (EN). Computed tomography images showed the presence of hepatic portal venous gas (HPVG). Urgent upper gastrointestinal endoscopy showed esophagogastric submucosal tunneling of the tube that required an emergency open total gastrectomy. Case 2 was a 76-year-old man with long-term EN after stroke. While the last auscultatory verification was normal, he suddenly developed extensive HPVG due to gastric mucosal injury following EN, which resulted in progressive intestinal necrosis, general peritonitis, and death. These 2 cases indicated that routine verification methods consisting of auscultation and X-ray may not be completely reliable, and the awareness of the limitations of these methods should be reaffirmed because expeditious examinations and necessary interventions are critical in preventing life-threatening complications.

  12. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center

    PubMed Central

    2012-01-01

    Background This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. Methods The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. Results The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Conclusions Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed. PMID:22691418

  13. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center.

    PubMed

    Kim, Hyung Min; So, Byung Hak; Jeong, Won Jung; Choi, Se Min; Park, Kyu Nam

    2012-06-12

    This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed.

  14. Flow rate of nutrient preparations through nasogastric tubes.

    PubMed Central

    Skidmore, F. D.

    1980-01-01

    Experiments have been carried out in vitro to determine the relationships between the internal diameter of fine-bore nasogastric tubes, the viscosity of nutrient solutions, and the flow rate that can be achieved in the enteral feeding of surgical patients. It was found that such tubes are capable of delivering 3-5 l of nutrient solution in 24 h without a pump. The findings are discussed in relation to the supply of nitrogen and energy to the patient. PMID:6772081

  15. [Effect of nasogastric tube on esophageal mucosa].

    PubMed

    Barinagarrementeria, R; Blancas Valencia, J M; Teramoto Matsubara, O; de la Garza González, S

    1991-01-01

    We studied 30 patients. 20 were males and 10 females. Mean age was 48 year old. Esophageal disease was not present neither gastro-esophageal reflux. Biopsy was taken between 24 hours and 25 days after nasogastric tube (NG) was put into place. Endoscopic findings were: hyperemic mucosa, submucosal hemorrhage, clots, erosions and ulcers near Esophago-gastric junction. Intraepithelial edema, vessel congestion, polymorphonuclear infiltration, fibrin thrombosis of submucosal vessels, ischemia, epithelial regeneration and ulcer were common histologic findings. All endoscopic and histologic alterations were related to the length of time of NG tube contact with the esophageal mucosa. We concluded that NG tube damages the esophageal mucosa by two mechanisms: a) Local irritation that favors b) gastric reflux by decreasing lower esophageal sphincter pressure.

  16. Using pH testing to confirm nasogastric tube position.

    PubMed

    Earley, Tracy

    In 2004 the MHRA published a directive for all hospitals in the UK to use pH paper in place of litmus paper when testing position of nasogastric tubes (NGT). This article illustrates one trust's implementation of this process of change in order to achieve compliance.

  17. Continuous nasogastric milk feeding versus intermittent bolus milk feeding for premature infants less than 1500 grams.

    PubMed

    Premji, Shahirose S; Chessell, Lorraine

    2011-11-09

    Milk feedings can be given via nasogastric tube either intermittently, typically over 10 to 20 minutes every two or three hours, or continuously, using an infusion pump. Although theoretical benefits and risks of each method have been proposed, effects on clinically important outcomes remain uncertain. To examine the evidence regarding the effectiveness of continuous versus intermittent bolus nasogastric milk feeding in premature infants less than 1500 grams. Searches were performed of the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 3, 2011), MEDLINE, CINAHL and HealthSTAR up to July 2011. Randomised and quasi-randomised clinical trials comparing continuous versus intermittent bolus nasogastric milk feeding in premature infants less than 1500 grams. Two review authors independently assessed all trials for relevance and methodologic quality. The standard methods of the Cochrane Neonatal Review Group were used to extract data. Overall, the seven included trials, involving 511 infants, found no differences in time to achieve full enteral feeds between feeding methods (weighted mean difference (WMD) 2 days; 95% CI -0.3 to 3.9) . In the subgroup analysis of those studies comparing continuous nasogastric versus intermittent bolus nasogastric milk feedings the findings remained unchanged (WMD 2 days, 95% CI -0.4 to 4.1). There was no significant difference in somatic growth and incidence of NEC between feeding methods irrespective of tube placement. One study noted a trend toward more apneas during the study period in infants fed by the continuous tube feeding method compared to those fed by intermittent feedings delivered predominantly by orogastric tube placements [mean difference (MD) 14.0 apneas during study period; 95% CI -0.2 to 28.2]. In subgroup analysis based on weight groups, one study suggested that infants less than 1000 grams and 1000 to 1250 grams birth weight gained weight faster when fed by the continuous

  18. Evaluation of nasogastric tubes to enable differentiation between upper and lower gastrointestinal bleeding in unselected patients with melena.

    PubMed

    Kessel, Boris; Olsha, Oded; Younis, Aurwa; Daskal, Yaakov; Granovsky, Emil; Alfici, Ricardo

    2016-02-01

    Gastrointestinal (GI) bleeding is a common surgical problem. The aim of this study was to evaluate how insertion of the nasogastric tube may enable differentiation between upper and lower GI bleeding in patients with melena. A retrospective study involving patients admitted to our surgery division with a melena was carried out between the years 2010 and 2012. A total of 386 patients were included in the study. Of these, 279 (72.2%) patients had negative nasogastric aspirate. The sensitivity of examination of nasogastric aspirate to establish the upper GI as the source of bleeding was only 28% and the negative predictive value of a negative nasogastric aspirate was less than 1%. Most patients who initially presented with melena and were found to have upper GI bleeding had a negative nasogastric aspirate. Insertion of a nasogastric tube does not affect the clinical decision to perform upper endoscopy and should not be routinely carried out.

  19. Discovering Innovation at the Intersection of Undergraduate Medical Education, Human Factors, and Collaboration: The Development of a Nasogastric Tube Safety Pack.

    PubMed

    Taylor, Natalie; Bamford, Thomas; Haindl, Cornelia; Cracknell, Alison

    2016-04-01

    Significant deficiencies exist in the knowledge and skills of medical students and residents around health care quality and safety. The theory and practice of quality and safety should be embedded into undergraduate medical practice so that health care professionals are capable of developing interventions and innovations to effectively anticipate and mitigate errors. Since 2011, Leeds Medical School in the United Kingdom has used case study examples of nasogastric (NG) tube patient safety incidents within the undergraduate patient safety curriculum. In 2012, a medical undergraduate student approached a clinician with an innovative idea after undertaking an NG tubes root cause analysis case study. Simultaneously, a separate local project demonstrated low compliance (11.6%) with the United Kingdom's National Patient Safety Agency NG tubes guideline for use of the correct method to check tube position. These separate endeavors led to interdisciplinary collaboration between a medical student, health care professionals, researchers, and industry to develop the Initial Placement Nasogastric Tube Safety Pack. Human factors engineering was used to inform pack design to allow guideline recommendations to be accessible and easy to follow. A timeline of product development, mapped against key human factors and medical device design principles used throughout the process, is presented. The safety pack has since been launched in five UK National Health Service (NHS) hospitals, and the pack has been introduced into health care professional staff training for NG tubes. A mixed-methods evaluation is currently under way in five NHS organizations.

  20. Real-time image-guided nasogastric feeding tube placement: A case series using Kangaroo with IRIS Technology in an ICU.

    PubMed

    Mizzi, Anna; Cozzi, Silvano; Beretta, Luigi; Greco, Massimiliano; Braga, Marco

    2017-05-01

    Pulmonary misplacement during the blind insertion of enteral feeding tubes is frequent, particularly in ventilated and neurologically impaired patients. This is probably the first clinical study using the Kangaroo Feeding Tube with IRIS technology (IRIS) which incorporates a camera designed to provide anatomic landmark visualization during insertion. The study aim was to evaluate IRIS performance during bedside gastric placement. This is the first prospective study to collect data on the use of IRIS. Twenty consecutive unconscious patients requiring enteral nutrition were recruited at a single center. IRIS placement was considered complete when a clear image of the gastric mucosa appeared. Correct placement was confirmed using a contrast-enhanced abdominal X-ray. To evaluate the device performance over time, the camera was activated every other day up to 17 d postplacement. In 7 (35%) patients, the trachea was initially visualized, requiring a second placement attempt with the same tube. The IRIS camera allowed recognition of the gastric mucosa in 18 (90%) patients. The esophagogastric junction was identified in one patient, while in a second patient the quality of visualization was poor. Contrast-enhanced X-ray confirmed the gastric placement of IRIS in all patients. IRIS allowed identification of gastric mucosa in 14 (70%) patients 3 d after placement. Performance progressively declined with time (P = 0.006, chi-square for trend). IRIS placement could have spared X-ray confirmation in almost all patients and prevented misplacement into the airway in about one third. Visualization quality needs to be improved, particularly after the first week. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Compounding rifampin suspensions with improved injectability for nasogastric enteral feeding tube administration.

    PubMed

    de Villiers, Melgardt M; Vogel, Laura; Bogenschutz, Monica C; Fingerhut, Bonnie J; D'Silva, Joseph B; Moore, Anne

    2010-01-01

    Often medications that have to be administered to patients via a nasogastric enteral feeding tubes are only available as tablets and capsules with no suitable commercial liquid alternatives. In such situations, pharmacists and nurses have to compound the tablets and capsule contents into liquid suspension formulations for dosing. The risk of occlusion of the enteral tubes during administration is reduced by employing liquid suspensions that are composed of small and uniform particles, not subject to rapid rates of settling, resistant to caking, and easily and uniformly re-suspended upon agitation. Present techniques often employ a manual process, such as a mortar and pestle, to accomplish the particle size reduction and subsequent incorporation into a suitable liquid diluent. A new compounding device has been invented that employs an automated wet-milling process in a single-use disposable plastic container to compound the suspensions. The two processes were compared using Rifampin capsules and various liquid diluents. A prototype version of the new device was employed in the experiments. The physical characteristics of the compounded suspensions were evaluated by determining sedimentation rate, sedimentation volume, and particle size and shape using laser light scattering, optical microscopy, and scanning electron microscopy techniques. The use characteristic of the compounded suspensions was evaluated using a nasogastric tube inject ability test. The results indicated that suspensions prepared using the new device were more resistant to sedimentation and caking and were easier to re-disperse into a uniform mixture by gentle shaking. The results were a consequence of the particles generated by the new device which were found to be smaller and more uniform in shape and size. The suspensions prepared using the new device did not cause blockage of the enteral feeding tubes in comparison to those prepared using a mortar and pastle. In conclusion, the results indicate

  2. Inflation with air via a facepiece for facilitating insertion of a nasogastric tube: a prospective, randomised, double-blind study.

    PubMed

    Gupta, D; Agarwal, A; Nath, S S; Goswami, D; Saraswat, V; Singh, P K

    2007-02-01

    Insertion of a nasogastric tube is a routine procedure but during anaesthesia it is often difficult and time consuming. One hundred and sixty adults undergoing elective surgery under general anaesthesia were randomly divided into two groups. After induction of anaesthesia, neuromuscular blockade and tracheal intubation, a nasogastric tube was inserted through the nose with the head of the patient in the neutral position, either with or without prior inflation with air via a facepiece attached to a self-inflating bag applied firmly with the face. Insertion of the nasogastric tube was successful in 75/78 (96%) following inflation compared with 54/80 (68%) without inflation (p<0.001). In four patients receiving inflation, a fibreoptic endoscope was passed as far as the upper oesophageal sphincter; this revealed opening of the upper oesophageal sphincter during inflation.

  3. [Is oral rehydration with nasogastric tube more efficient than rehydration with spoon? Preliminary study in children with non-severe dehydration in Joseph-Raseta-Befelatanana Hospital, Madagascar].

    PubMed

    Ravelomanana, T; Rabeatoandro, S; Randrianaivo, N; Ratsimbazafy, A; Raobijaona, H; Barennes, H

    2010-05-01

    Since its recommendation by WHO, Oral Rehydration Solutions (ORS) contributed in reducing the rate of mortality due to acute gastroenteritis. In Madagascar, the rate of lethality imputed to gastroenteritis is about 3%. Rehydration can be performed either by using spoons which reliability is unsure because of parents' potential inobservance and child's refusal, or by nasogastric tube. The nasogastric tube may resolve these obstacles at the hospital. We realized a preliminary study to evaluate the efficacy and the safety of nasogastric tube and spoon administration of the ORS in rehydration of child with moderate post-gastroenteritis dehydration. This is an open comparative study realized in the Pediatric Unit at the Joseph-Raseta-Befelatanana Hospital from the 21 January to 21 May 2008. Main outcomes was the proportion of rehydrated children at 4 hours, other were: failure at 8 hours, duration and volume of SRO, side effects. Fifty-three children from 4-month to 4-year old among 1306 patients were recruited and forty-seven patients were included. Nine patients failed (4 children received ORS by spoon and 5 children by nasogastric tube). The use of spoon was more effective: 62.5% of the patients were rehydrated at the fourth hour versus 39.3% in nasogastric tube group (P = 0.04). Making debit constant presents difficulties in rehydration with nasogastric tube (44.4 %). Tolerance of nasogastric tube is generally good but 16.7% children get out their tube during this study. No ORS' inhalation was observed with both routes. No false passage or tube or ORS rejection was recorded in both techniques. This study shows that using spoon to rehydrate is more effective for the rehydration of moderate dehydration. The use of nasogastric tube needs more surveillance.

  4. Deaths associated with insertion of nasogastric tubes for enteral nutrition in the medical intensive care unit: Clinical and autopsy findings

    PubMed Central

    Smith, Avery L.; Santa Ana, Carol A.; Fordtran, John S.; Guileyardo, Joseph M.

    2018-01-01

    ABSTRACT It is generally assumed that blind insertion of nasogastric tubes for enteral nutrition in patients admitted to medical intensive care units is safe; that is, does not result in life-threatening injury. If death occurs in temporal association with insertion of a nasogastric tube, caregivers typically attribute it to underlying diseases, with little or no consideration of iatrogenic death due to tube insertion. The clinical and autopsy results in three recent cases at Baylor University Medical Center challenge the validity of these notions. PMID:29904295

  5. A case report of esophageal perforation: Complication of nasogastric tube placement

    PubMed Central

    Isik, Arda; Firat, Deniz; Peker, Kemal; Sayar, Ilyas; Idiz, Oguz; Soytürk, Mehmet

    2014-01-01

    Patient: Male, 70 Final Diagnosis: Esophageal perforation Symptoms: Abdominal pain • nausea • vomiting Medication: — Clinical Procedure: — Specialty: Surgery Objective: Unusual clinical course Background: Esophageal perforation is a well-defined and severe clinical condition. There are several etiologies of esophagus perforation. Case Report: We report the case of a 70-year-old Caucasian man who underwent an emergency cholecystectomy due to acute cholecystitis. Two days after surgery, his condition deteriorated. Thorax computerized tomography revealed an esophageal perforation. Conclusions: Esophageal perforation due to nasogastric application is relatively rare but the consequences are potentially serious. The anatomy of the upper gastrointestinal system should be understood by all healthcare professionals involved in the treatment. PMID:24803977

  6. Successful treatment of severe Clostridium difficile infection by administration of crushed fidaxomicin via a nasogastric tube in a critically ill patient.

    PubMed

    Arends, Sven; Defosse, Jerome; Diaz, Cori; Wappler, Frank; Sakka, Samir G

    2017-02-01

    To report the successful use of crushed fidaxomicin via a nasogastric tube for treatment of a severe Clostridium difficile infection in a critically ill patient. Clinical observation of a patient, images of abdominal computed tomography, antimicrobial therapy and course of infection parameters. Relevant information contained in the medical observation of the patient and selection of image and laboratory parameters performed in the patient. We report a case of a 79-year old patient who developed septic shock with an increasing need for norepinephrine and acute renal failure due to a severe Clostridium difficile infection. Antimicrobial therapy with vancomycin via a nasogastric tube and metronidazole i.v. did not lead to improvement, infection parameters further increased, and the clinical condition became increasingly impaired. After 10 days, antimicrobial therapy was changed to fidaxomicin, crushed and administered via nasogastric tube. Within 24hours, infection parameters decreased. Further diarrhoea ceased and stool samples were negative for Clostridium difficile antigen. Our case confirms that administration of fidaxomicin via a nasogastric tube was safe and effective in this patient. Further studies are needed to evaluate the efficacy of this strategy in critically ill patients systematically. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  7. Transpyloric Feeding Tube Placement Using Electromagnetic Placement Device in Children.

    PubMed

    Goggans, Margaret; Pickard, Sharon; West, Alina Nico; Shah, Samir; Kimura, Dai

    2017-04-01

    Transpyloric feeding tubes (TPT) are often recommended in critically ill children. Blind tube placement, however, can be difficult, be time-consuming, and incur multiple radiation exposures. An electromagnetic device (EMD) is available for confirmation of successful placement of TPTs. We conducted a retrospective cohort study to evaluate the efficacy of an EMD for TPT placement in children and determine its impact on placement success, radiation exposure, confirmation time, and cost for tube placement compared with traditional blind TPT placement. Retrospective data were collected in patients receiving a TPT before (pre-EMD group) and after implementation of an EMD (EMD group). Need for radiographic exposure decreased significantly in the EMD group (n = 40) compared with the pre-EMD group (n = 38) (0.6 vs 1.6 x-rays, P < .001). TPTs were placed and confirmed without abdominal x-ray in 21 of 40 patients in the EMD group. There were no serious adverse events such as misplacement into the lung or pneumothorax or perforation injury of the stomach. Successful tube confirmation took a significantly shorter time in the EMD group than in the pre-EMD group (1.45 vs 4.59 hours, P < .0001). There was an estimated cost savings of $245.10 per placement associated with decreased x-ray and fluoroscopy. The use of an EMD in children significantly decreased radiation exposure and confirmation time while maintaining TPT placement success. The use of an EMD can potentially offer large cost savings. Elimination of abdominal x-ray with EMD during TPT placement was achieved without any serious complications in approximately half of the children.

  8. Evaluation of intensivist-nurses' knowledge concerning medication administration through nasogastric and enteral tubes.

    PubMed

    Mota, Maria Lurdemiler Sabóia; Barbosa, Islene Victor; Studart, Rita Mônica Borges; Melo, Elizabeth Mesquita; Lima, Francisca Elisângela Teixeira; Mariano, Fabíola Amaro

    2010-01-01

    This study evaluates the knowledge of nurses working in intensive care units concerning recommendations for the proper administration of medication through nasogastric and enteral tubes. This exploratory-descriptive study with a quantitative approach was carried out with 49 nurses in an intensive care unit of a tertiary hospital in Fortaleza, CE, Brazil. A total of 36.7% of nurses reported they disregard the dosage forms provided by the pharmacy at the time of administering the medication through tubes. Metal, wood, or a plastic mortar is the method most frequently reported (42.86%) for crushing prescribed solid forms; 32.65% leave the drugs in 20 ml of water until dissolved; 65.3% place the responsibility for choosing the pharmaceutical formulation and its correlation with the tube site, either into the stomach or into the intestine, on the physician. The results indicate there is a gap between specific literature on medication administered through tubes and knowledge of nurses on the subject.

  9. Comparison of complication rates in dogs with nasoesophageal versus nasogastric feeding tubes.

    PubMed

    Yu, Melissa K; Freeman, Lisa M; Heinze, Cailin R; Parker, Valerie J; Linder, Deborah E

    2013-01-01

    To compare complication rates between nasoesophageal (NE) and nasogastric (NG) feeding tubes in dogs. Retrospective study. University referral veterinary hospital. A total of 46 dogs that were fed through a NE (n = 28) or NG (n = 18) tube between January 2007 and December 2011 and that also had either thoracic radiography or computed tomography performed so that location of the distal tip of the tube in either the esophagus or stomach could be confirmed. None. The medical record of each eligible case was reviewed and data recorded included signalment, underlying disease, body weight, body condition score, medications, duration of feeding, diet used, and complications observed (ie, vomiting, regurgitation, diarrhea, early tube removal, clogged tube, epistaxis, pulmonary aspiration, hyperglycemia, and refeeding syndrome). Dogs with NE tubes were significantly younger than dogs with NG tubes (P = 0.03) but there were no other significant differences in signalment, underlying disease, medications, duration of anorexia, percent of resting energy requirement achieved, or change in weight during tube feeding. There also was no significant difference between the NE and NG groups for any of the recorded complications. Significantly fewer dogs in the NE group died or were euthanized (3/28) compared to the NG group (7/18; P = 0.02) but outcome was not associated with age, underlying disease, or any of the recorded tube complications. This study did not identify a difference in complication rate between NE and NG feeding tubes in dogs. Additional studies are required to determine the optimal terminal location of feeding tubes in dogs. © Veterinary Emergency and Critical Care Society 2013.

  10. Extraction of the plasticizers diethylhexylphthalate and polyadipate from polyvinylchloride nasogastric tubes through gastric juice and feeding solution.

    PubMed

    Subotic, Ulrike; Hannmann, Torsten; Kiss, Matthias; Brade, Joachim; Breitkopf, Katja; Loff, Steffan

    2007-01-01

    Except for polyadipate, which is used as an alternative in polyvinylchloride (PVC) feeding tubes, diethylhexylphthalate (DEHP) is the plasticizer used almost exclusively in PVC medical products. A clear response to the chronic intake of DEHP has been shown in several organ systems from different species. In the present study, we compared the extraction of DEHP and polyadipate from PVC gastric tubes. An in vivo setting was simulated. We used 5 cm of PVC nasogastric tubes containing DEHP or polyadipate, which were incubated with gastric juice for 1 week and a feeding solution for 4 weeks. The leakage of these plasticizers was measured daily in the gastric juice group and weekly in the feeding solution group. The amount of plasticizer extracted was compared between groups and days. In the feeding solution group, the extraction of DEHP ranged from 200 to 542 microg after 1 week and from 660 to 1700 microg after 4 weeks. The extraction of polyadipate was 10 times lower than that of DEHP. In the gastric juice group, extracted DEHP ranged from 635 to 1043 microg, whereas the extraction of polyadipate was 100 times lower. Within 1 week, the extraction of DEHP from a 5-cm PVC tube reaches up to 1 mg. Extrapolated, this represents an in vivo load of up to 4 mg. The load accumulated by a newborn in an intensive care unit can therefore easily reach several milligrams of DEHP per day. Polyadipate nasogastric tubes may therefore be an alternative and help to reduce the daily load of DEHP.

  11. A Non-invasive Real-time Localization System for Enhanced Efficacy in Nasogastric Intubation.

    PubMed

    Sun, Zhenglong; Foong, Shaohui; Maréchal, Luc; Tan, U-Xuan; Teo, Tee Hui; Shabbir, Asim

    2015-12-01

    Nasogastric (NG) intubation is one of the most commonly performed clinical procedures. Real-time localization and tracking of the NG tube passage at the larynx region into the esophagus is crucial for safety, but is lacking in current practice. In this paper, we present the design, analysis and evaluation of a non-invasive real-time localization system using passive magnetic tracking techniques to improve efficacy of the clinical NG intubation process. By embedding a small permanent magnet at the insertion tip of the NG tube, a wearable system containing embedded sensors around the neck can determine the absolute position of the NG tube inside the body in real-time to assist in insertion. In order to validate the feasibility of the proposed system in detecting erroneous tube placement, typical reference intubation trajectories are first analyzed using anatomically correct models and localization accuracy of the system are evaluated using a precise robotic platform. It is found that the root-mean-squared tracking accuracy is within 5.3 mm for both the esophagus and trachea intubation pathways. Experiments were also designed and performed to demonstrate that the system is capable of tracking the NG tube accurately in biological environments even in presence of stationary ferromagnetic objects (such as clinical instruments). With minimal physical modification to the NG tube and clinical process, this system allows accurate and efficient localization and confirmation of correct NG tube placement without supplemental radiographic methods which is considered the current clinical standard.

  12. Safety and Efficacy of Electromagnetic-Guided Bedside Placement of Nasoenteral Feeding Tubes versus Standard Placement.

    PubMed

    Shadid, Husam; Keckeisen, Maureen; Zarrinpar, Ali

    2017-10-01

    Although enteral feeding in critically ill patients has been shown to be beneficial, reliable postpyloric placement of feeding tubes remains a challenge. The standard of care involves blind placement, frequently requiring multiple attempts, and radiographs. To evaluate the effect of electromagnetic-guided bedside placement in reducing time to establishment of feeding, lung placement, use of radiography, and cost, we initiated a prospective trial using electromagnetic-guided bedside placement and compared them to a retrospective cohort. Fifty-three consecutive placements of nasoenteral feeding tubes were made using electromagnetic-guidance on patients requiring enteral nutrition in a surgical intensive care unit at a tertiary care center. Sixty-three placement attempts in the preceding seven months served as controls. There were no significant differences between the two groups in terms of age, sex, weight, body mass index, hiatal or ventral hernias, or previous esophageal/gastric operations. The number of radiographs needed per patient, need for fluoroscopy, radiology charge per patient for the tube placement, and time from first attempt at placement to confirmation of postpyloric location were lower for the electromagnetic-guided group. Use of electromagnetic guidance allows reliable and cost-effective postpyloric enteral feeding tube placement compared with blind insertion.

  13. [Study of bacterial flora in the oral cavity and stomach of elderly patients receiving nasogastric tube feeding].

    PubMed

    Matsuura, T; Suzuki, K; Yamakoshi, M; Yamamoto, T; Yamamoto, T; Yoshitomo, K; Tonegawa, K; Ariga, K; Odawara, F

    1997-05-01

    To investigate the significance of oropharyngeal flora and gastric flora in elderly patients receiving nasogastric tube feeding, throat secretions and gastric aspirates were cultured and the pH of the latter was measured. Of 116 bacterial isolates from throat secretions of 27 elderly patients, 30 were beta-streptococci and 28 were Pseudomonas aeruginosa. Bacteria isolated from gastric aspirates numbered 86 and 24 (27.9%) of them were the same species as those found in the throat secretions. Patients with gastric pH were below 3.5 had significantly lower concentrations of gram-negative bacili in gastric aspirates. We also studied oropharyngeal flora in 33 elderly patients who were admitted to Nagoyashi Koseiin Geriatric Hospital. The major bacterial isolates from throat swabs of bedridden patients were gram-negative bacilli and beta-streptococci, especially group B streptococci (GBS). We measured the level of antibody to GBS in these patients. Those from whom GBS were isolated had high titers. These results suggest that in elderly patients receiving enteral nasogastric) tube feeding, large numbers of bacteria colonize the oral cavity and stomach. The measurement of type-specific antibody to GBS may be useful in managing such patients.

  14. Interventions for maintaining nasogastric feeding after stroke: An integrative review of effectiveness and acceptability.

    PubMed

    Mahoney, Catherine; Veitch, Linda

    2018-02-01

    To investigate the effectiveness and acceptability of interventions for maintaining nasogastric tubes in adult stroke patients. Internationally, incidence of cerebral vascular disease continues to increase and stroke is the largest cause of complex disability in adults. Dysphagia is common following a stroke which necessitates feeding via a nasogastric tube. Nasogastric tubes are not well tolerated by stroke patients and may be frequently dislodged. Hence, interventions such as tape, the nasal bridle/loop or hand mittens may be used to maintain nasogastric tube position. However, evidence around the effectiveness and acceptability of these interventions has not been reviewed and synthesised. Integrative literature review. Database searches in MEDLINE, PubMed, CINAHL, Scopus, Cochrane and EMBASE; manual reference list searches. Seven studies met the eligibility criteria and were included in the review. Evidence for the effectiveness of nasal bridle/loop and hand mittens to maintain nasogastric tube position in patients after a stroke is spare and methodologically poor, and especially limited around hand mittens use. There is insufficient evidence about the acceptability of both nasal bridle/loop and hand mittens among stroke patients. Current clinical practice is underpinned by assumptions around the acceptability of nasal bridle/loop and hand mittens to secure nasogastric tubes. This results in reliance on consensual judgement between professional, patients and their families to guide their use among individuals with dysphagia after stroke. Further research is required to assess the effectiveness of hand mittens and acceptability of both nasal bridle/loop and hand mittens among stroke patients to inform guideline development. Given the lack of evidence on the acceptability of hand mittens and nasal bridle/loop among stroke patients to inform evidence-based guidelines and protocols, healthcare professionals should reach consensus on their use by exercising clinical

  15. Variables associated with feeding tube placement in head and neck cancer.

    PubMed

    Cheng, Sara S; Terrell, Jeffrey E; Bradford, Carol R; Ronis, David L; Fowler, Karen E; Prince, Mark E; Teknos, Theodoros N; Wolf, Gregory T; Duffy, Sonia A

    2006-06-01

    To identify clinical factors associated with enteral feeding tube placement in a head and neck cancer population. A self-administered survey was given to patients being treated for head and neck cancer while they were waiting to be seen in 1 of 4 otolaryngology clinics. The post hoc analysis presented here combines survey and chart review data to determine clinical and demographic variables associated with feeding tube placement. Four otolaryngology clinics. Otolaryngology clinic patients being treated for head and neck cancer. Enteral feeding tube placement. Of the 724 patients eligible for this study, 14% (n = 98) required enteral feeding tube placement. Multivariate analysis found the following variables to be independently associated with feeding tube placement: oropharynx/hypopharynx tumor site (odds ratio [OR], 2.4; P = .01), tumor stage III/IV (OR, 2.1; P = .03), flap reconstruction (OR, 2.2; P = .004), current tracheotomy (OR, 8.0; P<.001), chemotherapy (OR, 2.6; P<.001), and increased age (OR, 1.3; P = .02). In addition, there was a curvilinear relationship between time since treatment and feeding tube placement, with about 30% having a feeding tube at 1 month posttreatment, tapering down during the first 3 years to about 8% and leveling off thereafter. Identification of factors associated with an increased risk of feeding tube placement may allow physicians to better counsel patients regarding the possibility of feeding tube placement during treatment. Since feeding tube placement has been linked to decreased quality of life in head and neck cancer, such counseling is an integral part of the clinical management of these patients.

  16. Cooperative learning using simulation to achieve mastery of nasogastric tube insertion.

    PubMed

    Cason, Melanie Leigh; Gilbert, Gregory E; Schmoll, Heidi H; Dolinar, Susan M; Anderson, Jane; Nickles, Barbara Marshburn; Pufpaff, Laurie A; Henderson, Ruth; Lee, Frances Wickham; Schaefer, John J

    2015-03-01

    Traditionally, psychomotor skills training for nursing students involves didactic instruction followed by procedural review and practice with a task trainer, manikin, or classmates. This article describes a novel method of teaching psychomotor skills to associate degree and baccalaureate nursing students, Cooperative Learning Simulation Skills Training (CLSST), in the context of nasogastric tube insertion using a deliberate practice-to-mastery learning model. Student dyads served as operator and student learner. Automatic scoring was recorded in the debriefing log. Student pairs alternated roles until they achieved mastery, after which they were assessed individually. Median checklist scores of 100% were achieved by students in both programs after one practice session and through evaluation. Students and faculty provided positive feedback regarding this educational innovation. CLSST in a deliberate practice-to-mastery learning paradigm offers a novel way to teach psychomotor skills in nursing curricula and decreases the instructor-to-student ratio. Copyright 2015, SLACK Incorporated.

  17. Confirmation of nasogastric tube position by pH testing.

    PubMed

    Taylor, S J; Clemente, R

    2005-10-01

    In 2004, the Medicines and Healthcare products Regulatory Agency (MHRA) advised that nasogastric (NG) tube position should be confirmed using pH strips or paper. However, gastric pH is raised by the use of H2-blockers and proton-pump inhibitors (PPIs) potentially producing false negative pH tests resulting in delayed feeding. In addition, colorimetric differentiation using pH strips may be more prone to bias and inaccuracy than direct pH measurements largely used to establish the threshold. To quantify this problem a 1 day survey of all the patients requiring NG and nasointestinal (NI) feeding was undertaken, to establish the numbers of patients receiving H2-Blockers or PPIs, with or without a safe swallow and the methods currently being used to confirm tube positioning. A second observational study was performed to establish the accuracy of six pH strips available to NHS trusts against four unlabelled pH solutions. Forty-two per cent of patients receiving NG feeding were on H2-blockers or PPIs, including 13% who had a safe swallow for acidic drinks that could be subsequently aspirated to confirm position. In the second study 'testers' correctly identified pH's 3, 4, 5 and 6 with Mackery-Nagel 0-6, BDH 0-6 and 0-14 strips but overestimated pH 4 as pH 5 with Johnson 0-11 paper, underestimated pH 6 as pH 5 with Pehanon 0-12 paper and with Litmus classified pH 3-5 as acid (all), but half also classified pH 6 as acid. Theoretically 29% of NG tube positions could not be confirmed by pH testing because of the usage of PPIs or H2-blockers and lack of swallow. Some pH strips are either inaccurate or their result misinterpreted by staff. Large surveys and trials of the actual efficacy and accuracy of pH testing are required.

  18. [Nasogastric rehydration for treating children with gastroenteritis].

    PubMed

    Rébeillé-Borgella, B; Barbier, C; Moussaoui, R; Faisant, A; Michard-Lenoir, A-P; Rubio, A

    2017-06-01

    When oral rehydration is not feasible, enteral rehydration via the nasogastric route has been the ESPGHAN recommended method of rehydration since 2008, rather than intravenous rehydration (IVR), for children with acute gastroenteritis. However, these recommendations are rarely followed in France. Since 2011, in case of failure of oral rehydration, enteral rehydration has been used as a first-line therapy in the Children's Emergency Department at the Grenoble-Alpes University Hospital. The aims of the study were to compare the length of the hospital stay, the duration of initial rehydration, and the incidence of complications and failure with the use of enteral nasogastric versus intravenous rehydration. This study compared two cohorts of children (<3 years of age) with mild-to-moderate dehydration caused by acute gastroenteritis and failure of rehydration via the oral route. The first group (winter 2010-2011) was managed according to the previous protocol (intravenous rehydration). The second group (winter 2011-2012) was managed according the new protocol (nasogastric tube rehydration [NGR]). The rest of the gastroenteritis management was identical in both groups. A total of 132 children were included, 65 were treated with nasogastric tube rehydration (NGR) and 67 with intravenous rehydration. There was a significant reduction in the duration of hospitalization in the post-emergency unit in the NGR group: 23.6h vs 40.1h (P<0.05). The duration of initial rehydration was also significantly reduced (10.5h vs 22.0h). There was no significant difference regarding serious adverse events. However, the NGR group presented more mild adverse events (22 vs 7, P<0.05) and more treatment failures (15.3% vs 3%, P=0.013). Nasogastric rehydration reduces the duration of rehydration and the length of the hospital stay without increasing the incidence of serious adverse events for dehydrated children hospitalized for acute gastroenteritis. Copyright © 2017 Elsevier Masson SAS. All

  19. Intranasal fluticasone associated with delayed tympanostomy tube placement in children with eustachian tube dysfunction.

    PubMed

    Crowson, Matthew G; Ryan, Marisa A; Ramprasad, Vaibhav H; Choi, Kevin J; Raynor, Eileen

    2017-03-01

    Pediatric patient caregivers may prefer to avoid a surgical intervention and request a medical management option for eustachian tube dysfunction (ETD). However, there are limited published data evaluating the efficacy of intranasal fluticasone in the medical management of ETD as an alternative to tympanostomy tube placement. The objectives of this study were to: 1) determine if intranasal fluticasone (INF) prevented tympanostomy tube placement in children with ETD, and 2) describe differences in patient response to INF related to cleft lip and/or palate (CLP) and Down syndrome. Case series with planned chart review at a Tertiary academic hospital. We reviewed pediatric patients treated with INF for ETD. Inclusion criteria included ETD, no prior intranasal or oral steroid therapy, and no prior tympanostomy tube placement. Outcomes included time-to- tympanostomy tube placement with or without INF and therapy compliance. Kaplan-Meier survival analyses with log-rank tests and Fisher's exact tests were used to examine outcome variables. 676 fulfilled inclusion criteria. 393 (58.7%) were male, and 355 (52.5%) Caucasian with mean age of 27.1 months old. 92 (13.6%) had CLP and 46 (6.8%) had Down Syndrome. 266 (39.4%) received INF, and 202 (88.2%) were compliant at their next visit. 474 (70.1%) had tympanostomy tubes placed. Children treated with INF were less likely to have tympanostomy tubes placed than children not treated (52.6% vs. 81.5%; p < 0.0001). Using survival analyses, INF use was associated with significantly longer mean time-to-tympanostomy tube than no INF use (199.4 vs. 133.7 days; p < 0.0001). INF did not reduce time-to-tympanostomy tube in patients with CLP (p = 0.05) or Down Syndrome (p = 0.27). INF significantly reduces the number of children requiring tympanostomy tube placement for ETD. The CLP and Down Syndrome anatomical variants may attenuate INF efficacy. Further in vivo characterization of INF action on eustachian tube tissues will help

  20. Gastrostomy versus nasogastric tube feeding for chemoradiation patients with head and neck cancer: the TUBE pilot RCT.

    PubMed

    Paleri, Vinidh; Patterson, Joanne; Rousseau, Nikki; Moloney, Eoin; Craig, Dawn; Tzelis, Dimitrios; Wilkinson, Nina; Franks, Jeremy; Hynes, Ann Marie; Heaven, Ben; Hamilton, David; Guerrero-Urbano, Teresa; Donnelly, Rachael; Barclay, Stewart; Rapley, Tim; Stocken, Deborah

    2018-04-01

    Approximately 9000 new cases of head and neck squamous cell cancers (HNSCCs) are treated by the NHS each year. Chemoradiation therapy (CRT) is a commonly used treatment for advanced HNSCC. Approximately 90% of patients undergoing CRT require nutritional support via gastrostomy or nasogastric tube feeding. Long-term dysphagia following CRT is a primary concern for patients. The effect of enteral feeding routes on swallowing function is not well understood, and the two feeding methods have, to date (at the time of writing), not been compared. The aim of this pilot randomised controlled trial (RCT) was to compare these two options. This was a mixed-methods multicentre study to establish the feasibility of a RCT comparing oral feeding plus pre-treatment gastrostomy with oral feeding plus as-required nasogastric tube feeding in patients with HNSCC. Patients were recruited from four tertiary centres treating cancer and randomised to the two arms of the study (using a 1 : 1 ratio). The eligibility criteria were patients with advanced-staged HNSCC who were suitable for primary CRT with curative intent and who presented with no swallowing problems. The primary outcome was the willingness to be randomised. A qualitative process evaluation was conducted alongside an economic modelling exercise. The criteria for progression to a Phase III trial were based on a hypothesised recruitment rate of at least 50%, collection of outcome measures in at least 80% of those recruited and an economic value-of-information analysis for cost-effectiveness. Of the 75 patients approached about the trial, only 17 consented to be randomised [0.23, 95% confidence interval (CI) 0.13 to 0.32]. Among those who were randomised, the compliance rate was high (0.94, 95% CI 0.83 to 1.05). Retention rates were high at completion of treatment (0.94, 95% CI 0.83 to 1.05), at the 3-month follow-up (0.88, 95% CI 0.73 to 1.04) and at the 6-month follow-up (0.88, 95% CI 0.73 to 1.04). No serious adverse

  1. Verifying placement of small-bore feeding tubes: electromagnetic device images versus abdominal radiographs.

    PubMed

    Bryant, Vera; Phang, Jean; Abrams, Kevin

    2015-11-01

    Clinicians are unsure if radiography is needed to confirm correct positioning of feeding tubes inserted with assistance from an electromagnetic system. To compare radiographic reports of feeding tube placement with images generated by an electromagnetic feeding tube placement device. The medical records of 200 consecutive patients who had feeding tubes inserted with assistance from an electromagnetic feeding tube placement device were reviewed retrospectively. Radiographic reports of tube site were compared with images generated by the device. Radiographic evidence of tube sites was available in 188 cases: 184 tubes were located in portions of the gastrointestinal tract. Ninety of the 188 tubes were situated in the optimal site (distal duodenum or jejunum) radiographically. Images generated by the electromagnetic device were available in 176 cases; of these, 52 tubes appeared to end in the expected left lower quadrant. Tubes shown on radiographs to be in other sites also occasionally appeared to end in the left lower quadrant. Nurses using the device did not recognize 4 of the 188 tubes (2.1%) that were inadvertently placed in the lung. No consistent pattern of quadrant distribution was found for tubes positioned in the stomach or proximal duodenum. Images generated by the electromagnetic tube placement device provided inconsistent results regarding tube location. A small percentage of seriously malpositioned tubes were not detected by using the electromagnetic device. These findings do not support eliminating radiographs to confirm correct tube placement following use of an electromagnetic tube placement device. ©2015 American Association of Critical-Care Nurses.

  2. Colorimetric carbon dioxide detector to determine accidental tracheal feeding tube placement.

    PubMed

    Howes, Daniel W; Shelley, Eric S; Pickett, William

    2005-04-01

    To determine the accuracy of colorimetric CO2 detection compared to the reference standard two-step radiological confirmation of feeding tube position. A prospective study was conducted with patients presenting to a 21-bed medical-surgical intensive care unit. An adapter was developed using an endotracheal tube adapter to connect a colorimetric CO2 detector to a feeding tube in an airtight manner. In part I of the study a feeding tube connected to the colorimeter was inserted into the endotracheal tubes of ten ventilated patients to test the device's ability to detect tracheal placement. In part II patients undergoing feeding tube insertion had tube position confirmed with the colorimeter as well as the reference standard two-step x-ray. In phase I the colorimeter correctly identified tracheal placement in all ten patients. In phase II 93/100 procedures ultimately were eligible; the colorimeter had a sensitivity of 0.88 (95% confidence interval: 0.65-1.00) and specificity of 0.99 (0.97-1.00). The device missed one of the eight tracheal placements. Agreement between the colorimeter and two-step x-ray interpretations was excellent (Kappa 0.86; standard error 0.10). We describe a novel, convenient method to confirm esophageal feeding tube placement. The device is easily assembled and inexpensive, but should not be reused. Colorimetric determination of tracheal feeding tube placement with this device has excellent agreement with the reference standard two-step radiological technique.

  3. Confirmation of gastric tube bedside placement with the sky blue method.

    PubMed

    Imamura, Takashi; Maeda, Hajime; Kinoshita, Hidetoshi; Shibukawa, Yasuko; Suda, Kiyomi; Fukuda, Yutaka; Goto, Aya; Nagasawa, Katsutoshi

    2014-02-01

    The purpose was to review our experiences and determine if applying the sky blue method is reliable in confirming gastric tube (GT) placement in neonates. The study population consisted of 44 infants (55 placements) who were admitted to the Takeda General Hospital between April 2012 and March 2013 and who required GT exchange. The sky blue method using indigo carmine (IC) was indicated for planned tube exchange only. Diluted IC was injected into the gastric space via the old GT just before the tube exchange. The tube was exchanged using a standard method. Then, we checked whether the diluted IC could be collected through the new GT or not. The reasons for GT placement were a gestational age of < 35 weeks in 31 (56.4%), poor sucking or swallowing disorders in 17 (30.4%), and respiratory disorders in 7 (12.7%) of the 55 placements. GT placement using the sky blue method was considered successful in 52 placements (94.4%), with the remaining 3 placements (5.6%) considered to be failures due to the inability to obtain IC from the gastric space. No adverse events were observed during the tube exchange period. Based on the results, the sky blue method can be considered to be reliable method for the confirmation of GT placement. These results also suggest that the number of radiologic evaluations performed to confirm correct replacement of the GT in infants can be reduced in the future.

  4. Nasogastric tube versus gastrostomy tube for gastric decompression in abdominal surgery: a prospective, randomized trial comparing patients' tube-related inconvenience.

    PubMed

    Hoffmann, S; Koller, M; Plaul, U; Stinner, B; Gerdes, B; Lorenz, W; Rothmund, M

    2001-11-01

    Perioperative decompression of the stomach is still a common procedure and can be achieved using either nasogastric tubes (NTs) or gastrostomy tubes (GTs). While both procedures appear to be equally effective, some authors believe that NTs are less convenient for patients than GTs. However, to date, no reliable prospective data are available on this issue. We conducted a prospective, randomized trial comparing NTs versus GTs with a total of 110 patients undergoing elective colon surgery. The primary outcome measure was the patient's tube-related inconvenience and pain, assessed in a standardized interview on day 2 after surgery and quantified by means of a visual-analog scale (VAS). A questionnaire including the EORTC QLQ-C30 and additional items regarding retrospective tube-related judgements was administered on the day of discharge and 4 weeks after discharge. Secondary endpoints were the therapy-related morbidity and general complications. When patients were asked which of their drainage tubes (all patients had three or four drainage tubes, such as decompression drains, urinary drains, central venous line) was most inconvenient, 43% (CI 33-53%) in the NT group reported that the NT was most inconvenient, while only 4% (CI 1-10%) of the GT patients judged the GT most inconvenient ( P<0.001, Chi(2) test). This effect was also found in VAS ratings of inconvenience and discomfort ( P<0.01). Also postoperatively (p.o.), NT patients evidenced less preference for their tube system (day 2 p.o.: 71%, CI 61-80%; 4 weeks p.o.: 66%, CI 56-75%) than did GT patients (day 2 p.o.: 94%, CI 88-98%; 4 weeks p.o.: 91% CI 84-96%); again, these differences were statistically significant ( P<0.02; Chi(2) test). No differences between groups emerged regarding global quality of life or conventional clinical outcomes. This prospective randomized trial supports the clinical observation that NT causes more subjective inconvenience than GT. In cases when a prolonged postoperative ileus is

  5. Underwater-seal nasogastric tube drainage to relieve gastric distension caused by air swallowing.

    PubMed

    Solomon, A W; Bramall, J C; Ball, J

    2011-02-01

    Air swallowing can occur as a psychogenic phenomenon, because of abnormal anatomy, or during non-invasive positive pressure ventilation. Gross distension of the stomach with air can have severe consequences for the respiratory and gastrointestinal systems. We report the case of a 62-year-old man with severe dynamic hyperinflation due to chronic obstructive pulmonary disease, who developed respiratory failure requiring intubation a few hours after radical prostatectomy. Following a percutaneous tracheostomy and weaning of sedation on day six, his abdomen began to enlarge progressively. X-rays revealed massive gastric distension due to air swallowing, which continued despite all efforts to optimise therapy. The use of an underwater seal drainage system on a nasogastric tube improved ventilation and ultimately aided weaning from mechanical support. © 2010 The Authors. Anaesthesia © 2010 The Association of Anaesthetists of Great Britain and Ireland.

  6. Gastric digestion of α-lactalbumin in adult human subjects using capsule endoscopy and nasogastric tube sampling.

    PubMed

    Sullivan, Louise M; Kehoe, Joseph J; Barry, Lillian; Buckley, Martin J M; Shanahan, Fergus; Mok, K H; Brodkorb, André

    2014-08-28

    In the present study, structural changes in the milk protein α-lactalbumin (α-LA) and its proteolysis were investigated for the potential formation of protein-fatty acid complexes during in vivo gastric digestion. Capsule endoscopy allowed visualisation of the digestion of the test drinks, with nasogastric tubes allowing sampling of the gastric contents. A total of ten healthy volunteers had nasogastric tubes inserted into the stomach and ingested test drinks containing 50 g/l of sucrose and 25 g/l of α-LA with and without 4 g/l of oleic acid (OA). The samples of gastric contents were collected for analysis at 3 min intervals. The results revealed a rapid decrease in the pH of the stomach of the subjects. The fasting pH of 2·31 (SD 1·19) increased to a pH maxima of pH 6·54 (SD 0·29) after ingestion, with a subsequent decrease to pH 2·22 (SD 1·91) after 21 min (n 8). Fluorescence spectroscopy and Fourier transform IR spectroscopy revealed partial protein unfolding, coinciding with the decrease in pH below the isoelectric point of α-LA. The activity of pepsin in the fasting state was found to be 39 (SD 12) units/ml of gastric juice. Rapid digestion of the protein occurred: after 15 min, no native protein was detected using SDS-PAGE; HPLC revealed the presence of small amounts of native protein after 24 min of gastric digestion. Mirocam® capsule endoscopy imaging and video clips (see the online supplementary material) revealed that gastric peristalsis resulted in a heterogeneous mixture during gastric digestion. Unfolding of α-LA was observed during gastric transit; however, there was no evidence of a cytotoxic complex being formed between α-LA and OA.

  7. Electromagnetic-guided placement of nasoduodenal feeding tubes versus endoscopic placement: a randomized, multicenter trial.

    PubMed

    Kappelle, Wouter F W; Walter, Daisy; Stadhouders, Paul H; Jebbink, Hendrik J A; Vleggaar, Frank P; van der Schaar, Peter J; Kappelle, Jan Willem; van der Tweel, Ingeborg; Van den Broek, Medard F M; Wessels, Frank J; Siersema, Peter D; Monkelbaan, Jan F

    2018-01-01

    Electromagnetic-guided placement (EMP) of a nasoduodenal feeding tube by trained nurses is an attractive alternative to EGD-guided placement (EGDP). We aimed to compare EMP and EGDP in outpatients, ward patients, and critically ill patients with normal upper GI anatomy. In 3 centers with no prior experience in EMP, patients were randomized to placement of a single-lumen nasoduodenal feeding tube either with EGDP or EMP. The primary endpoint was post-pyloric position of the tube on abdominal radiography. Patients were followed for 10 days to assess patency and adverse events. The analyses were performed according to the intention-to-treat principle. In total, 160 patients were randomized to EGDP (N = 76) or EMP (N = 84). Three patients withdrew informed consent, and no abdominal radiography was performed in 2 patients. Thus, 155 patients (59 intensive care unit, 38%) were included in the analyses. Rates of post-pyloric tube position between EGDP and EMP were comparable (79% vs 82%, odds ratio 1.16; 90% confidence interval, 0.58-2.38; P = .72). Adverse events were observed in 4 patients after EMP (hypoxia, GI blood loss, atrial fibrillation, abdominal pain) and in 4 after EGDP (epistaxis N = 2, GI blood loss, hypoxia). Costs of tube placements were lower for EMP compared with EGDP: $519.09 versus $622.49, respectively (P = .04). Success rates and safety of EMP and EGDP in patients with normal upper GI anatomy were comparable. Lower costs and potential logistic advantages may drive centers to adopt EMP as their new standard of care. (Clinical trial registration number: NTR4286.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  8. Incidence of hypochloremic metabolic alkalosis in dogs and cats with and without nasogastric tubes over a period of up to 36 hours in the intensive care unit.

    PubMed

    Chih, Annie; Rudloff, Elke; Waldner, Cheryl; Linklater, Andrew K J

    2018-05-01

    To evaluate the incidence of hypochloremic metabolic alkalosis (HCMA) in dogs and cats in the ICU that had intermittent nasogastric tube (NGT) aspiration for up to 36 hours. Prospective cohort study (December 2013 to October 2014). Privately owned emergency and referral teaching hospital. Forty-nine client-owned dogs and 16 client-owned cats. Patients wherein NGT placement was recommended and client consent was obtained were included in the interventional group. Those with an NGT placed (NGT group) had the NGT aspirated every 4 hours. Patients for whom placement of a NGT was declined by the owner served as a reference group (NoNGT). Venous blood gas and electrolyte values were obtained every 12 hours. Thirty-five dogs and cats had an NGT placed. Thirty dogs and cats did not have an NGT placed. The serum venous blood gas and electrolyte changes were compared over time within the NGT group and between the NGT and NoNGT groups. No cases developed HCMA. In the NGT group, blood pH increased over time. There was no significant difference between the NGT and the NoNGT group in the average value of pH, HCO 3 - , base excess, chloride, or corrected chloride. Serum venous blood gas, chloride, and corrected chloride changes were not associated with the volumes of gastric fluid aspirated over time. In this small population of dogs and cats, intermittent NGT aspiration was not associated with the development of HCMA over a period of up to 36 hours after NGT placement. © Veterinary Emergency and Critical Care Society 2018.

  9. Role of the Nasogastric Tube and Lingzhi (Ganoderma lucidum) in Palliative Care.

    PubMed

    Wang, Xiaohui; Huang, Youyi; Radha Krishna, Lalit; Puvanendran, Rukshini

    2016-04-01

    Decision-making on behalf of an incapacitated patient at the end of life is a complex process, particularly in family-centric societies. The situation is more complex when attempts are made to accommodate Eastern concepts of end-of-life care with more conventional Western approaches. In this case report of an incapacitated 74-year-old Singaporean man of Malay descent with relapsed Stage 4 diffuse large B cell lymphoma who was without an established lasting power of attorney, we highlight the difficult deliberations that ensue when the patient's family, acting as his proxy, elected to administer lingzhi through his nasogastric tube (NGT). Focusing on the questions pertaining to end-of-life decision-making in Asia, we consider the issues surrounding the use of NGT and lingzhi in palliative care (PC) and the implementation of NGT for administering lingzhi in a PC setting, particularly in light of a dearth of data on such treatment measures among PC patients. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  10. Nasogastric feeding tube located in the lung. SENSAR case of the trimester.

    PubMed

    2017-01-01

    A clinical case is presented that was communicated to Spanish Notification System on Safety in Anaesthesia and Recovery (SENSAR). Using this communication and its analysis, a strategy is obtained in order to reduce the risks associated with the insertion of a nasogastric tube (NST) for enteral nutrition in adult patients in the post-surgical recovery unit. A description of the incident is presented, an analysis of its causes, and the measures that were introduced in order to avoid similar incidents in the future, as well as to promote a safety culture in the organisation. A description of associated incidents registered in SENSAR is also given. The aim of this work is to describe, analyse and introduce safety measures arising from incidents notified to SENSAR, associated with the insertion and checking of the nutrition NST in adult patients in the post-surgical recovery unit. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Establishing Decision Trees for Predicting Successful Postpyloric Nasoenteric Tube Placement in Critically Ill Patients.

    PubMed

    Chen, Weisheng; Sun, Cheng; Wei, Ru; Zhang, Yanlin; Ye, Heng; Chi, Ruibin; Zhang, Yichen; Hu, Bei; Lv, Bo; Chen, Lifang; Zhang, Xiunong; Lan, Huilan; Chen, Chunbo

    2016-08-31

    Despite the use of prokinetic agents, the overall success rate for postpyloric placement via a self-propelled spiral nasoenteric tube is quite low. This retrospective study was conducted in the intensive care units of 11 university hospitals from 2006 to 2016 among adult patients who underwent self-propelled spiral nasoenteric tube insertion. Success was defined as postpyloric nasoenteric tube placement confirmed by abdominal x-ray scan 24 hours after tube insertion. Chi-square automatic interaction detection (CHAID), simple classification and regression trees (SimpleCart), and J48 methodologies were used to develop decision tree models, and multiple logistic regression (LR) methodology was used to develop an LR model for predicting successful postpyloric nasoenteric tube placement. The area under the receiver operating characteristic curve (AUC) was used to evaluate the performance of these models. Successful postpyloric nasoenteric tube placement was confirmed in 427 of 939 patients enrolled. For predicting successful postpyloric nasoenteric tube placement, the performance of the 3 decision trees was similar in terms of the AUCs: 0.715 for the CHAID model, 0.682 for the SimpleCart model, and 0.671 for the J48 model. The AUC of the LR model was 0.729, which outperformed the J48 model. Both the CHAID and LR models achieved an acceptable discrimination for predicting successful postpyloric nasoenteric tube placement and were useful for intensivists in the setting of self-propelled spiral nasoenteric tube insertion. © 2016 American Society for Parenteral and Enteral Nutrition.

  12. Establishing Decision Trees for Predicting Successful Postpyloric Nasoenteric Tube Placement in Critically Ill Patients.

    PubMed

    Chen, Weisheng; Sun, Cheng; Wei, Ru; Zhang, Yanlin; Ye, Heng; Chi, Ruibin; Zhang, Yichen; Hu, Bei; Lv, Bo; Chen, Lifang; Zhang, Xiunong; Lan, Huilan; Chen, Chunbo

    2018-01-01

    Despite the use of prokinetic agents, the overall success rate for postpyloric placement via a self-propelled spiral nasoenteric tube is quite low. This retrospective study was conducted in the intensive care units of 11 university hospitals from 2006 to 2016 among adult patients who underwent self-propelled spiral nasoenteric tube insertion. Success was defined as postpyloric nasoenteric tube placement confirmed by abdominal x-ray scan 24 hours after tube insertion. Chi-square automatic interaction detection (CHAID), simple classification and regression trees (SimpleCart), and J48 methodologies were used to develop decision tree models, and multiple logistic regression (LR) methodology was used to develop an LR model for predicting successful postpyloric nasoenteric tube placement. The area under the receiver operating characteristic curve (AUC) was used to evaluate the performance of these models. Successful postpyloric nasoenteric tube placement was confirmed in 427 of 939 patients enrolled. For predicting successful postpyloric nasoenteric tube placement, the performance of the 3 decision trees was similar in terms of the AUCs: 0.715 for the CHAID model, 0.682 for the SimpleCart model, and 0.671 for the J48 model. The AUC of the LR model was 0.729, which outperformed the J48 model. Both the CHAID and LR models achieved an acceptable discrimination for predicting successful postpyloric nasoenteric tube placement and were useful for intensivists in the setting of self-propelled spiral nasoenteric tube insertion. © 2016 American Society for Parenteral and Enteral Nutrition.

  13. Conservative Surgical Approach to Restore Necrotic Columella in Patients Undergoing Neonatal Usage of Nasogastric Tube.

    PubMed

    Inchingolo, Francesco; Abenavoli, Fabio Massimo; De Angelis, Francesca; Orefici, Alessandro; Santacroce, Luigi; Dipalma, Gianna

    2017-01-01

    A common complication, related to the use of nasogastric tube during the 1 st day of life, is the necrosis of the columella. Esthetic damage in the early age typically leads to a healing request with very high result expectations. We aimed to develop and use an innovative surgical technique. We used our technique in four cases. Our technique requires two flaps designed with two paramedian release incisions. The two flaps will be sutured to what remains of the fibrous septum; finally, the two flaps will be sutured together in the medial region. Postoperative course was devoid of any complication. All patients gained esthetic improvements and an increase in the volume of the columella on the sagittal and frontal planes. This technique allows a conservative approach with low donor site morbidity and rapid postoperative course.

  14. Enteral nutrition tube placement assisted by ultrasonography in patients with severe acute pancreatitis

    PubMed Central

    Li, Gang; Pan, Yiyuan; Zhou, Jing; Tong, Zhihui; Ke, Lu; Li, Weiqin

    2017-01-01

    Abstract To evaluate the effect of a novel procedure using real-time ultrasonography to assist nasojejunal tube placement at bedside in patients with severe acute pancreatitis (SAP). Single center, prospective descriptive study in a 15-bed surgery intensive care unit of a university hospital. Thirty SAP patients were enrolled. The whole procedure of placing nasojejunal tube was performed by a single physician, who places nasojejunal tube at the bedside and performs ultrasonography to guide the tube positioning. The final nasojejunal tube position was confirmed by abdominal radiograph. The successful rate of the procedure as well as the time it took, the time from the decision of enteral feeding to commencement of feeding, and complications were recorded. Thirty-six intubations were performed in 30 patients by using ultrasonography-assisted method at bedside. Nasojejunal tubes were successful placed in 28 of 30 patients (93.3%). The average time of successful placement was 22.07 ± 5.78 minutes. The median time between physician's decision for tube placement and feeding initiation was 5.5 (2, 24) hours. No adverse events occurred in all of patients. This novel method of nasojejunal tube placement under ultrasound guidance is practical, less time consuming and reliable. PMID:29137035

  15. The practice of gastrostomy tube placement across a Canadian regional health authority.

    PubMed

    Pruthi, Deepak; Duerksen, Donald R; Singh, Harminder

    2010-07-01

    We sought to conduct an assessment of the practice of gastrostomy (G) tube placement across an entire city, which would reflect usual clinical care as compared with referral center practice. We reviewed and retrospectively extracted data from patient records for all percutaneous endoscopic G (PEG) and radiological percutaneous G (RPG) tube placements at six Winnipeg hospitals between 1 April 2005 and 31 March 2007. A total of 418 patients had G tubes (376 PEG, 42 RPG) inserted during the study period. The most common indications were cerebrovascular accidents (25%), head and neck cancer (23%), and head trauma (10%). The position of the external bolster was not documented in 38% of patients. The median time to the first complication was 10 days, initiation of feeding was 48 hours, and tube removal was 40 days. Complications developed in 102 (24%) patients. Patients with RPG tubes had more infections and were less likely to receive prophylactic antibiotics (P<0.001). In multivariate analysis, complications were more likely to occur in patients with RPG tubes and after insertions by lowest procedure volume physicians. Overall mortality was 12% within 30 days of G-tube placement. Death of one patient was directly related to peritonitis after G-tube insertion. In usual clinical practice, there is an underuse of prophylactic antibiotics and a delay in the institution of nutritional support after G-tube placement. A small but significant proportion of patients may develop major complications, with associated risk of mortality. The higher complication rate after procedures performed by lowest volume physicians needs further evaluation.

  16. Retrospective analysis of insulin responses to standard dosed oral glucose tests (OGTs) via naso-gastric tubing towards definition of an objective cut-off value.

    PubMed

    Warnken, Tobias; Delarocque, Julien; Schumacher, Svenja; Huber, Korinna; Feige, Karsten

    2018-01-19

    Insulin dysregulation (ID) with basal or postprandial hyperinsulinemia is one of the key findings in horses and ponies suffering from the equine metabolic syndrome (EMS). Assessment of ID can easily be performed in clinical settings by the use of oral glucose challenge tests. Oral glucose test (OGT) performed with 1 g/kg bodyweight (BW) glucose administered via naso-gastric tube allows the exact administration of a defined glucose dosage in a short time. However, reliable cut-off values have not been available so far. Therefore, the aim of the study was to describe variations in insulin response to OGT via naso-gastric tubing and to provide a clinical useful cut-off value for ID when using the insulin quantification performed with an equine-optimized insulin enzyme-linked immunosorbent assay. Data visualization revealed no clear separation in the serum insulin concentration of insulin sensitive and insulin dysregulated horses during OGT. Therefore, a model based clustering method was used to circumvent the use of an arbitrary limit for categorization. This method considered all data-points for the classification, taking into account the individual insulin trajectory during the OGT. With this method two clusters were differentiated, one with low and one with high insulin responses during OGT. The cluster of individuals with low insulin response was consistently detected, independently of the initialization parameters of the algorithm. In this cluster the 97.5% quantile of insulin is 110 µLU/mL at 120 min. We suggest using this insulin concentration of 110 µLU/mL as a cut-off value for samples obtained at 120 min in OGT. OGT performed with 1 g/kg BW glucose and administration via naso-gastric tubing can easily be performed under clinical settings. Application of the cut-off value of 110 µLU/mL at 120 min allows assessment of ID in horses.

  17. Rivaroxaban crushed tablet suspension characteristics and relative bioavailability in healthy adults when administered orally or via nasogastric tube.

    PubMed

    Moore, Kenneth T; Krook, Mark A; Vaidyanathan, Seema; Sarich, Troy C; Damaraju, C V; Fields, Larry E

    2014-07-01

    Because some patients have difficulty swallowing a whole tablet, we investigated the relative bioavailability of a crushed 20 mg rivaroxaban tablet and of 2 alternative crushed tablet dosing strategies. Stability and nasogastric (NG) tube adsorption characteristics of a crushed rivaroxaban tablet were assessed. Then, in 55 healthy adults, relative bioavailability of rivaroxaban administered orally as a whole tablet (Reference [Whole-Oral]), crushed tablet in applesauce suspension (Crushed-Oral), or crushed tablet in water suspension via NG tube (Crushed-NG) were determined. There were no significant changes in mean percent of non-degraded rivaroxaban recovered over 4 hours from crushed tablet suspensions (>98.4% recovery across all suspensions and time points) or after NG tube exposure (recovery: 99.1% for silicone and 98.9% for polyvinyl chloride NG tubes). Relative bioavailability was similar between Crushed-Oral and Reference dosing (Cmax and AUC∞ were within the 80-125% bioequivalence limits). Relative bioavailability was also similar between the Crushed-NG and Reference dosing (AUC∞ was within bioequivalence limits; Cmax [90% CI range: 78.5-85.8%] was only slightly below the 80% lower bioequivalence limit). A crushed rivaroxaban tablet was stable and when administered orally or via NG tube, displayed similar relative bioavailability compared to a whole tablet administered orally. © 2014, The American College of Clinical Pharmacology.

  18. [Nasogastric tube feeding in bulimia. Controlled study with follow-up at 3 months].

    PubMed

    Rigaud, Daniel; Brayer, Véronique; Biton-Jélic, Violaine; Païs, Vanessa; Pennacchio, Hélène; Brun, Jean-Marcel

    2007-10-01

    Few effective treatments are available for severe forms of bulimia nervosa, which are accompanied by malnutrition, anxiety, and depressive mood. We previously showed in an open study that nasogastric tube feeding (TF) reduced binges and purging in patients with anorexia nervosa. This prospective randomized trial compared bulimia patients in two treatment groups: one group received TF at home, together with psychotherapy, nutritional counseling and a support group while the control group received only psychotherapy, nutritional counseling, and a support group. Patients in the first group underwent TF for 8 weeks (exclusively for 10 days and associated with meals thereafter). Assessment was based on clinical examination, laboratory results, and a variety of questionnaires (our in-house instrument for measuring binge and vomiting episodes, eating disorder inventory, Beck's depression inventory and the Hamilton rating scale for anxiety), all performed at the onset of treatment and at 8 days, 8 weeks (i.e., the end of TF), and 3 months after treatment began. Binges and vomiting disappeared faster and more frequently in TF patients than in the control group: 65% versus 29% (p<0.01). Three months later, these remained less frequent in the TF group than among controls (52% versus 33%, p=0.064). Nutritional status, depression, and anxiety improved more among the TF than control subjects (p<0.05). Tube feeding was effective in these patients with bulimia nervosa, reducing the number of binge and vomiting episodes and improving nutritional status and mood.

  19. Endoscopic placement of Jones lacrimal tubes with the assistance of holmium YAG laser.

    PubMed

    Boboridis, Kostas G; Downes, Richard N

    2005-06-01

    The aim of this paper is to highlight the use of the Holmium YAG laser in the endoscopic placement of Lester Jones tubes in patients with a blocked canaliculus or failed lacrimal pump function. Sixteen cases with a non-functional canaliculus were included over a one-year period. Following caruncle excision, a 19 G needle is inserted through the medial canthal tissues into the nasal space. Nasal endoscopy confirms the accurate positioning in relation to the nasal anatomy. With the Holmium YAG laser, a tissue channel is fashioned around the guide needle through the structures of the lateral nasal wall to facilitate an accurate and secure placement of the Jones tube. The endoscopic, laser-assisted placement reduces the operating time to less than 20 minutes, minimizes tissue trauma and does not require the initial surgical steps of an open DCR procedure. There were 14 cases (87.5%) with securely retained tubes and two cases (12.5%) that required tube replacement. The advantage of the procedure is especially great in revision surgery where the ostium is opened through scar tissue. Nasal endoscopy with the assistance of the Holmium YAG laser offers simplicity and precision in the placement of Jones tubes. It minimizes tissue trauma and increases the surgical success rate.

  20. The molecular characterisation of Escherichia coli K1 isolated from neonatal nasogastric feeding tubes.

    PubMed

    Alkeskas, Aldukali; Ogrodzki, Pauline; Saad, Mohamed; Masood, Naqash; Rhoma, Nasreddin R; Moore, Karen; Farbos, Audrey; Paszkiewicz, Konrad; Forsythe, Stephen

    2015-10-26

    The most common cause of Gram-negative bacterial neonatal meningitis is E. coli K1. It has a mortality rate of 10-15 %, and neurological sequelae in 30-50 % of cases. Infections can be attributable to nosocomial sources, however the pre-colonisation of enteral feeding tubes has not been considered as a specific risk factor. Thirty E. coli strains, which had been isolated in an earlier study, from the residual lumen liquid and biofilms of neonatal nasogastric feeding tubes were genotyped using pulsed-field gel electrophoresis, and 7-loci multilocus sequence typing. Potential pathogenicity and biofilm associated traits were determined using specific PCR probes, genome analysis, and in vitro tissue culture assays. The E. coli strains clustered into five pulsotypes, which were genotyped as sequence types (ST) 95, 73, 127, 394 and 2076 (Achman scheme). The extra-intestinal pathogenic E. coli (ExPEC) phylogenetic group B2 ST95 serotype O1:K1:NM strains had been isolated over a 2 week period from 11 neonates who were on different feeding regimes. The E. coli K1 ST95 strains encoded for various virulence traits associated with neonatal meningitis and extracellular matrix formation. These strains attached and invaded intestinal, and both human and rat brain cell lines, and persisted for 48 h in U937 macrophages. E. coli STs 73, 394 and 2076 also persisted in macrophages and invaded Caco-2 and human brain cells, but only ST394 invaded rat brain cells. E. coli ST127 was notable as it did not invade any cell lines. Routes by which E. coli K1 can be disseminated within a neonatal intensive care unit are uncertain, however the colonisation of neonatal enteral feeding tubes may be one reservoir source which could constitute a serious health risk to neonates following ingestion.

  1. Relative bioavailability of single doses of prolonged-release tacrolimus administered as a suspension, orally or via a nasogastric tube, compared with intact capsules: a phase 1 study in healthy participants.

    PubMed

    Undre, Nasrullah; Dickinson, James

    2017-04-04

    Tacrolimus, an immunosuppressant widely used in solid organ transplantation, is available as a prolonged-release capsule for once-daily oral administration. In the immediate postsurgical period, if patients cannot take intact capsules orally, tacrolimus therapy is often initiated as a suspension of the capsule contents, delivered orally or via a nasogastric tube. This study evaluated the relative bioavailability of prolonged-release tacrolimus suspension versus intact capsules in healthy participants. A phase 1, open-label, single-dose, cross-over study. A single clinical research unit. In total, 20 male participants, 18-55 years old, entered and completed the study. All participants received nasogastric administration of tacrolimus 10 mg suspension in treatment period 1, with randomisation to oral administration of suspension or intact capsules in periods 2 and 3. Blood concentration-time profile over 144 hours was used to estimate pharmacokinetic parameters. Primary end point: relative bioavailability of prolonged-release intact capsule versus oral or nasogastric administration of prolonged-release tacrolimus suspension (area under the concentration-time curve (AUC) from time 0 to infinity post-tacrolimus dose (AUC 0-∞ ); AUC measured until the last quantifiable concentration (AUC 0-tz ); maximum observed concentration (C max ); time to C max (T max )). Tolerability was assessed throughout the study. Relative bioavailability of prolonged-release tacrolimus suspension administered orally was similar to intact capsules, with a ratio of least-square means for AUC 0-tz and AUC 0-∞ of 1.05 (90% CI 0.96 to 1.14). Bioavailability was lower with suspension administered via a nasogastric tube versus intact capsules (17%; ratio 0.83; CI 0.76 to 0.92). C max was higher for oral and nasogastric suspension (30% and 28%, respectively), and median T max was shorter (difference 1.0 and 1.5 hours postdose, respectively) versus intact capsules (2.0 hours). Single 10

  2. Colorimetric end-tidal CO2 detector for verification of endotracheal tube placement in out-of-hospital cardiac arrest.

    PubMed

    Hayden, S R; Sciammarella, J; Viccellio, P; Thode, H; Delagi, R

    1995-06-01

    To evaluate the ability of a disposable, colorimetric end-tidal CO2 detector to verify proper endotracheal (ET) tube placement in out-of-hospital cardiac arrest, and to correlate semiquantitative CO2 measurements with the rate of return of spontaneous circulation (ROSC). Prospective, observational study using a convenience sample of intubated out-of-hospital cardiac arrest patients. A disposable, colorimetric end-tidal CO2 detector was attached to the ET tube after intubation. In the absence of a colorimetric change, the paramedics reassessed the tube placement and could reintubate the patient. Tube placement was verified at the hospital. Paramedics were instructed to contact the base station and report the colorimetric change upon hospital arrival. ROSC was defined as restoration of a self-sustaining pulse until hospital arrival. Between December 1990 and May 1993, ET tubes were placed in 566 victims of out-of-hospital cardiac arrest. 541 of the 566 intubations (95.6%) were associated with a color change. In one case with a color change and out-of-hospital clinical evidence of proper tube placement, the tube was determined to be in the esophagus at the hospital. Correct placement of the remaining 565 of 566 (99.8%) tubes was verified. Of the 566 patients who had a colorimetric change, 91 (16%) had ROSC vs one of 25 (4%) patients who did not have a color change. In one subgroup (n = 179), the degree of color change was highly associated with ROSC (p = 0.004). A disposable, colorimetric end-tidal CO2 detector appears reliable in verifying proper ET tube placement in victims of out-of-hospital cardiac arrest. The degree of color change correlates with the probability of ROSC.

  3. Is nasogastric tube drainage required after reconstructive surgery for neurogenic bladder dysfunction?

    PubMed

    Erickson, Bradley A; Dorin, Ryan P; Clemens, J Quentin

    2007-05-01

    To determine whether the routine use of nasogastric tubes (NGTs) after bowel surgery for neurogenic bladder dysfunction improves outcomes. We retrospectively evaluated 54 consecutive patients (30 women, 24 men) with neurogenic bladder who underwent bladder reconstruction or replacement with bowel segments by one surgeon from December 2000 to August 2005. The first 32 [NGT(+)] had NGTs placed during the procedure, whereas the subsequent 22 [NGT(-)] did not. We compared short-term postoperative outcomes between groups. Patient age ranged from 17 to 74 years (mean, 42.6 years). Procedures included augmentation cystoplasty with or without creation of catheterizable stoma (31), ileovesicostomy (13), and ileal conduit (9). Mean age or mean operative time did not differ between the NGT(+) and NGT(-) groups. The NGT(-) patients experienced less time to oral intake (3.1 versus 4.4 days, P <0.01), fewer days to flatus (2.9 versus 4.0 days, P = 0.01), and fewer days to first bowel movement (4.4 versus 5.9 days, P = 0.01). We found no statistical differences in the incidence of postoperative complications. Overall hospital days were less in the NGT(-) patients, but this did not reach statistical significance (9.9 versus 11.0, P = 0.2). Routine use of NGTs in patients undergoing bladder reconstruction or replacement for neurogenic bladder dysfunction seems to confer no benefit. The omission of NGTs in this population is possible without increasing overall morbidity. These findings parallel those previously reported in neurologically intact patients undergoing urinary diversion.

  4. Blind bedside postpyloric placement of spiral tube as rescue therapy in critically ill patients: a prospective, tricentric, observational study.

    PubMed

    Lv, Bo; Hu, Linhui; Chen, Lifang; Hu, Bei; Zhang, Yanlin; Ye, Heng; Sun, Cheng; Zhang, Xiunong; Lan, Huilan; Chen, Chunbo

    2017-09-26

    Various special techniques for blind bedside transpyloric tube placement have been introduced into clinical practice. However, transpyloric spiral tube placement facilitated by a blind bedside method has not yet been reported. The objective of this prospective study was to evaluate the safety and efficiency of blind bedside postpyloric placement of a spiral tube as a rescue therapy subsequent to failed spontaneous transpyloric migration in critically ill patients. This prospective, tricentric, observational study was conducted in the intensive care units (ICUs) of three tertiary hospitals. A total of 127 consecutive patients with failed spontaneous transpyloric spiral tube migration despite using prokinetic agents and still required enteral nutrition for more than 3 days were included. The spiral tube was inserted postpylorically using the blind bedside technique. All patients received metoclopramide intravenously prior to tube insertion. The exact tube tip position was determined by radiography. The primary efficacy endpoint was the success rate of postpyloric spiral tube placement. Secondary efficacy endpoints were success rate of a spiral tube placed in the third portion of the duodenum (D3) or beyond, success rate of placement in the proximal jejunum, time to insertion, length of insertion, and number of attempts. Safety endpoints were metoclopramide-related and major adverse tube-associated events. In 81.9% of patients, the spiral feeding tubes were placed postpylorically; of these, 55.1% were placed in D3 or beyond and 33.9% were placed in the proximal jejunum, with a median time to insertion of 14 min and an average number of attempts of 1.4. The mean length of insertion was 95.6 cm. The adverse event incidence was 26.0%, and no serious adverse event was observed. Blind bedside postpyloric placement of a spiral tube, as a rescue therapy subsequent to failed spontaneous transpyloric migration in critically ill patients, is safe and effective. This

  5. A Comparative Analysis of Nasogastric and Intravenous Fluid Resuscitation in Patients with Malignant Obstructive Jaundice Prior to Endoscopic Biliary Drainage

    PubMed Central

    Baghel, Kavita; Raj, Saloni; Awasthi, Induja; Gupta, Vishal; Chandra, Abhijit; Srivastava, Rajeshwar Nath

    2013-01-01

    Background: An alternative to intravenous is nasogastric fluid administration through normal functioning gut. Though not common, this practice has significance in mass causalities and elective situations. Aim: The study was designed to compare nasogastric and intravenous fluid resuscitation in malignant obstructive jaundice (OJ) and their effect on endotoxemia. Materials and Methods: Sixty patients with malignant OJ undergoing endoscopic biliary drainage were randomized into two groups. A total of 4 l of fluid (Ringer's lactate) was administered to Group A through nasogastric tube and to Group B through intravenous route for 48 h. Vital parameters, serum bilirubin, serum creatinine, creatinine clearance rate, electrolytes, and endotoxemia were monitored. Results: Significant improvement in blood pressure (Group A, P = 0.014; Group B, P = 0.020) and significant decrease in serum bilirubin level (Group A, P = 0.001; Group B, P > 0.0001) was observed in both groups after resuscitation. Significantly decreased (P = 0.036) post hydration endotoxin level was observed in Group A as compared to Group B. Febrile events were significantly higher (P = 0.023) in Group B as compared to Group A (6 vs 0). Electrolyte abnormalities were found more in Group B, however statistically insignificant. Conclusion: In OJ patient undergoing biliary drainage, preoperative fluid resuscitation through nasogastric tube may be helpful in reducing postoperative septic complications and endotoxemia. PMID:24251269

  6. Evaluation of crushed ticagrelor tablet doses: recovery following crushing and naso-gastric tube passage ex vivo.

    PubMed

    Crean, Barry; Finnie, Cindy; Crosby, Anna

    2013-06-01

    Orally available ticagrelor in combination with low-dose aspirin (75-100 mg/day) is indicated for adult patients with acute coronary syndromes. However, patients with swallowing difficulties may be unable to consume the currently available 90-mg tablet. It is hypothesized that ticagrelor could be given to this patient cohort as a crushed dose administered either orally or via a naso-gastric (NG) tube. To investigate the potential use of crushed ticagrelor tablets (90- and 180-mg doses) for oral dose or NG tube administration. Ticagrelor tablets (90 or 180 mg [two 90-mg tablets]) were prepared to emulate oral and NG tube administration by similar methods. For the oral dose, ticagrelor tablets were crushed using a mortar and pestle and transferred to a dosing cup. 100 mL of water was added to the mortar, stirred, and the contents were transferred to the dosing cup and stirred to form a suspension. At this stage, where the suspension would normally be administered to a patient, it was collected for high performance liquid chromatography (HPLC) analysis. The mortar was then flushed with 100 mL of water, and the contents were again transferred to the dosing cup, stirred, and collected for HPLC analysis. For the NG dose, polyvinylchloride, polyurethane, and silicone size CH10 NG tubes were used. The tablets were crushed using a mortar and pestle, diluted with 50 mL of water, and stirred. At this stage, where the suspension would normally be administered to a patient through an NG tube using a syringe, it was collected for HPLC analysis. The mortar was then flushed with two additional 50 mL aliquots of water and the contents were passed through the NG tube. HPLC analysis examined the recoverability of ticagrelor in each of the dose suspensions and flushes and the stability of the suspension when held in a syringe for up to 2 h. One or two crushed 90-mg ticagrelor tablets, prepared for either oral or NG tube administration, delivers a mean dose of ≥97% of the original

  7. Percutaneous endoscopic gastrostomy versus nasogastric tube feeding for patients with head and neck cancer: a systematic review

    PubMed Central

    Wang, Jinfeng; Liu, Minjie; Liu, Chao; Ye, Yun; Huang, Guanhong

    2014-01-01

    There are two main enteral feeding strategies—namely nasogastric (NG) tube feeding and percutaneous gastrostomy—used to improve the nutritional status of patients with head and neck cancer (HNC). But up till now there has been no consistent evidence about which method of enteral feeding is the optimal method for this patient group. To compare the effectiveness of percutaneous gastrostomy and NGT feeding in patients with HNC, relevant literature was identified through Medline, Embase, Pubmed, Cochrane, Wiley and manual searches. We included randomized controlled trials (RCTs) and non-experimental studies comparing percutaneous gastrostomy—including percutaneous endoscopic gastrostomy (PEG) and percutaneous fluoroscopic gastrostomy (PFG) —with NG for HNC patients. Data extraction recorded characteristics of intervention, type of study and factors that contributed to the methodological quality of the individual studies. Data were then compared with respect to nutritional status, duration of feeding, complications, radiotherapy delays, disease-free survival and overall survival. Methodological quality of RCTs and non-experimental studies were assessed with separate standard grading scales. It became apparent from our studies that both feeding strategies have advantages and disadvantages. PMID:24453356

  8. Percutaneous endoscopic gastrostomy versus nasogastric tube feeding for patients with head and neck cancer: a systematic review.

    PubMed

    Wang, Jinfeng; Liu, Minjie; Liu, Chao; Ye, Yun; Huang, Guanhong

    2014-05-01

    There are two main enteral feeding strategies-namely nasogastric (NG) tube feeding and percutaneous gastrostomy-used to improve the nutritional status of patients with head and neck cancer (HNC). But up till now there has been no consistent evidence about which method of enteral feeding is the optimal method for this patient group. To compare the effectiveness of percutaneous gastrostomy and NGT feeding in patients with HNC, relevant literature was identified through Medline, Embase, Pubmed, Cochrane, Wiley and manual searches. We included randomized controlled trials (RCTs) and non-experimental studies comparing percutaneous gastrostomy-including percutaneous endoscopic gastrostomy (PEG) and percutaneous fluoroscopic gastrostomy (PFG) -with NG for HNC patients. Data extraction recorded characteristics of intervention, type of study and factors that contributed to the methodological quality of the individual studies. Data were then compared with respect to nutritional status, duration of feeding, complications, radiotherapy delays, disease-free survival and overall survival. Methodological quality of RCTs and non-experimental studies were assessed with separate standard grading scales. It became apparent from our studies that both feeding strategies have advantages and disadvantages.

  9. Assessment of routine elimination of postoperative nasogastric decompression after Roux-en-Y gastric bypass.

    PubMed

    Huerta, Sergio; Arteaga, James R; Sawicki, Mark P; Liu, Carson D; Livingston, Edward H

    2002-11-01

    Anastomotic disruption after surgical intervention is an infrequent complication, but may lead to severe morbidity and mortality when it occurs. Of the various gastric procedures, the Roux-en-Y gastric bypass (RYGB) has one of the highest risks for anastomotic leakage. Consequently, a nasogastric tube (NGT) is frequently placed when these operations are performed. Most studies examining the outcomes for patients without postoperative NGTs have been relatively small with groups of patients undergoing a variety of operations. Assessing the incidence of anastomotic leaks by routine elimination of postoperative NGTs requires a large number of patients. In this study, we assessed the safety and efficacy of routine elimination of NGTs in a large cohort of patients undergoing a single operation. We reviewed our experience with 1067 patients who underwent RYGB at the UCLA medical center. Fifty-six patients had NGTs routinely placed before the implementation of a standard protocol, which eliminated postoperative NGT decompression. The complication rate for the RYGB patient cohort with and without postoperative NGT was compared. We found no difference in the complication rates between the 2 groups (Fisher exact test; P =.21). Our findings suggest that routine placement of an NGT after RYGB is unnecessary.

  10. Buried bumper syndrome revisited: a rare but potentially fatal complication of PEG tube placement.

    PubMed

    Biswas, Saptarshi; Dontukurthy, Sujana; Rosenzweig, Mathew G; Kothuru, Ravi; Abrol, Sunil

    2014-01-01

    Percutaneous endoscopic gastrostomy (PEG) has been used for providing enteral access to patients who require long-term enteral nutrition for years. Although generally considered safe, PEG tube placement can be associated with many immediate and delayed complications. Buried bumper syndrome (BBS) is one of the uncommon and late complications of percutaneous endoscopic gastrostomy (PEG) placement. It occurs when the internal bumper of the PEG tube erodes into the gastric wall and lodges itself between the gastric wall and skin. This can lead to a variety of additional complications such as wound infection, peritonitis, and necrotizing fasciitis. We present here a case of buried bumper syndrome which caused extensive necrosis of the anterior abdominal wall.

  11. Percutaneous transesophageal gastro-tubing (PTEG) as an alternative long-term tube feeding procedure when gastrostomy is not feasible

    PubMed Central

    Toh Yoon, Ezekiel Wong; Nishihara, Kazuki

    2017-01-01

    Background: Percutaneous transesophageal gastro-tubing (PTEG) is a minimally invasive technique to access the gut via an esophagostomy. However, this procedure is not well known and the literature available is still fairly limited. This observational study was conducted to evaluate our experience using this method as an alternative long-term tube feeding procedure when gastrostomy is not suitable. Methods: A total of 15 patients (10 males and 5 females) who underwent PTEG at our institution from 2012 to 2016 were observed and analyzed in this study. Results: The average age was 80.1 (71–93) years. Underlying conditions that required PTEG were previous gastric resection in 11 patients, left diaphragm disorder in 2 patients, interposing transverse colon between the abdominal wall and anterior gastric wall in 1 patient, and severe gastrostomy site leakage in 1 patient. Tube placement was successful in all patients by approaching the left side of the neck, using a 15 Fr size tube. The mean postoperative length of stay was 22 (8–48) days. Postoperative adverse events included accidental tube dislodgement in three patients, tracheoesophageal fistula in one patient, inferior thyroid artery injury in one patient and thyroid gland mispuncture in one patient. There was no procedure-related mortality nor mortality at 30 days. Eight patients were discharged with some oral intake. Conclusions: PTEG is feasible in patients requiring long-term tube feeding for whom gastrostomy is unsuitable. It is an effective long-term tube feeding procedure and should be offered as a more comfortable alternative to nasogastric tubing. PMID:29204186

  12. Percutaneous transesophageal gastro-tubing (PTEG) as an alternative long-term tube feeding procedure when gastrostomy is not feasible.

    PubMed

    Toh Yoon, Ezekiel Wong; Nishihara, Kazuki

    2017-12-01

    Percutaneous transesophageal gastro-tubing (PTEG) is a minimally invasive technique to access the gut via an esophagostomy. However, this procedure is not well known and the literature available is still fairly limited. This observational study was conducted to evaluate our experience using this method as an alternative long-term tube feeding procedure when gastrostomy is not suitable. A total of 15 patients (10 males and 5 females) who underwent PTEG at our institution from 2012 to 2016 were observed and analyzed in this study. The average age was 80.1 (71-93) years. Underlying conditions that required PTEG were previous gastric resection in 11 patients, left diaphragm disorder in 2 patients, interposing transverse colon between the abdominal wall and anterior gastric wall in 1 patient, and severe gastrostomy site leakage in 1 patient. Tube placement was successful in all patients by approaching the left side of the neck, using a 15 Fr size tube. The mean postoperative length of stay was 22 (8-48) days. Postoperative adverse events included accidental tube dislodgement in three patients, tracheoesophageal fistula in one patient, inferior thyroid artery injury in one patient and thyroid gland mispuncture in one patient. There was no procedure-related mortality nor mortality at 30 days. Eight patients were discharged with some oral intake. PTEG is feasible in patients requiring long-term tube feeding for whom gastrostomy is unsuitable. It is an effective long-term tube feeding procedure and should be offered as a more comfortable alternative to nasogastric tubing.

  13. Quality of life improvement after pressure equalization tube placement in Down syndrome: A prospective study.

    PubMed

    Labby, Alex; Mace, Jess C; Buncke, Michelle; MacArthur, Carol J

    2016-09-01

    To evaluate quality-of-life changes after bilateral pressure equalization tube placement with or without adenoidectomy for the treatment of chronic otitis media with effusion or recurrent acute otitis media in a pediatric Down syndrome population compared to controls. Prospective case-control observational study. The OM Outcome Survey (OMO-22) was administered to both patients with Down syndrome and controls before bilateral tube placement with or without adenoidectomy and at an average of 6-7 months postoperatively. Thirty-one patients with Down syndrome and 34 controls were recruited. Both pre-operative and post-operative between-group and within-group score comparisons were conducted for the Physical, Hearing/Balance, Speech, Emotional, and Social domains of the OMO-22. Both groups experienced improvement of mean symptom scores post-operatively. Patients with Down syndrome reported significant post-operative improvement in mean Physical and Hearing domain item scores while control patients reported significant improvement in Physical, Hearing, and Emotional domain item scores. All four symptom scores in the Speech domain, both pre-operatively and post-operatively, were significantly worse for Down syndrome patients compared to controls (p ≤ 0.008). Surgical placement of pressure equalizing tubes results in significant quality of life improvements in patients with Down syndrome and controls. Problems related to speech and balance are reported at a higher rate and persist despite intervention in the Down syndrome population. It is possible that longer follow up periods and/or more sensitive tools are required to measure speech improvements in the Down syndrome population after pressure equalizing tube placement ± adenoidectomy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Innovative Technique for the Placement of the Drainage Tube for Microendoscopic Spinal Decompression.

    PubMed

    Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2017-02-01

    A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.

  15. Minority race and male sex as risk factors for non-beneficial gastrostomy tube placements after stroke.

    PubMed

    Faigle, Roland; Carrese, Joseph A; Cooper, Lisa A; Urrutia, Victor C; Gottesman, Rebecca F

    2018-01-01

    Percutaneous endoscopic gastrostomy (PEG) tubes are widely used for enteral feeding after stroke; however, PEG tubes placed in patients in whom death is imminent are considered non-beneficial. We sought to determine whether placement of non-beneficial PEG tubes differs by race and sex. In this retrospective cohort study, inpatient admissions for stroke patients who underwent palliative/withdrawal of care, were discharged to hospice, or died during the hospitalization, were identified from the Nationwide Inpatient Sample between 2007 and 2011. Logistic regression was used to evaluate the association between race and sex with PEG placement. Of 36,109 stroke admissions who underwent palliative/withdrawal of care, were discharge to hospice, or experienced in-hospital death, a PEG was placed in 2,258 (6.3%). Among PEG recipients 41.1% were of a race other than white, while only 22.0% of patients without PEG were of a minority race (p<0.001). The proportion of men was higher among those with compared to without a PEG tube (50.0% vs. 39.2%, p<0.001). Minority race was associated with PEG placement compared to whites (OR 1.75, 95% CI 1.57-1.96), and men had 1.27 times higher odds of PEG compared to women (95% CI 1.16-1.40). Racial differences were most pronounced among women: ethnic/racial minority women had over 2-fold higher odds of a PEG compared to their white counterparts (OR 2.09, 95% CI 1.81-2.41), while male ethnic/racial minority patients had 1.44 increased odds of a PEG when compared to white men (95% CI 1.24-1.67, p-value for interaction <0.001). Minority race and male sex are risk factors for non-beneficial PEG tube placements after stroke.

  16. The who, what, why, and how-to guide for gastrostomy tube placement in infants.

    PubMed

    Burd, Angela; Burd, Randall S

    2003-08-01

    The decision to place a gastrostomy tube in an infant can be confusing and difficult for both parents and professionals. A unified team approach is critical to communication and collaboration. Once the decision is made, coordinated parent education, discharge planning, and community integration are essential to facilitate a safe discharge. This article reviews the indications and options for gastrostomy placement, outlines current concepts in gastrostomy tube care, and answers the most frequently asked questions about the discharge and home care of infants with a gastrostomy tube.

  17. Temporal comparison of ultrasound vs. auscultation and capnography in verification of endotracheal tube placement.

    PubMed

    Pfeiffer, P; Rudolph, S S; Børglum, J; Isbye, D L

    2011-11-01

    This study compared the time consumption of bilateral lung ultrasound with auscultation and capnography for verifying endotracheal intubation. A prospective, paired, and investigator-blinded study carried out in the operating theatre. Twenty-five adult patients requiring endotracheal intubation were included. During intubation, transtracheal ultrasound was performed to visualize passage of the endotracheal tube. During bag ventilation, bilateral lung ultrasound was performed for the detection of lung sliding as a sign of ventilation simultaneous with capnography and auscultation of the epigastrium and chest. Primary outcome measure was time difference to confirmed endotracheal intubation between ultrasound and auscultation alone. Secondary outcome measure was time difference between ultrasound and auscultation combined with capnography. Both methods verified endotracheal tube placement in all patients. In 68% of patients, endotracheal tube placement was visualized by real-time transtracheal ultrasound. Comparing ultrasound with the combination of auscultation and capnography, there was a significant difference between the two methods. Median time for ultrasound was 40 s [interquartile range (IQR) 35-48 s] vs. 48 s (IQR 45-53 s), P < 0.0001. Mean difference was -7.1 s in favour of ultrasound [95% confidence interval (CI) -9.4--4.8 s]. No significant difference was found between ultrasound compared with auscultation alone. Median time for auscultation alone was 42 s (IQR 37-47 s), P = 0.6, with a mean difference of -0.88 s in favour of ultrasound (95% CI -4.2-2.5 s). Verification of endotracheal tube placement with ultrasound is as fast as auscultation alone and faster than the standard method of auscultation and capnography. © 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  18. Nasogastric Hydration in Infants with Bronchiolitis Less Than 2 Months of Age.

    PubMed

    Oakley, Ed; Bata, Sonny; Rengasamy, Sharmila; Krieser, David; Cheek, John; Jachno, Kim; Babl, Franz E

    2016-11-01

    To determine whether nasogastric hydration can be used in infants less than 2 months of age with bronchiolitis, and characterize the adverse events profile of these infants compared with infants given intravenous (IV) fluid hydration. A descriptive retrospective cohort study of children with bronchiolitis under 2 months of age admitted for hydration at 3 centers over 3 bronchiolitis seasons was done. We determined type of hydration (nasogastric vs IV fluid hydration) and adverse events, intensive care unit admission, and respiratory support. Of 491 infants under 2 months of age admitted with bronchiolitis, 211 (43%) received nonoral hydration: 146 (69%) via nasogastric hydration and 65 (31%) via IV fluid hydration. Adverse events occurred in 27.4% (nasogastric hydration) and 23.1% (IV fluid hydration), difference of 4.3%; 95%CI (-8.2 to 16.9), P = .51. The majority of adverse events were desaturations (21.9% nasogastric hydration vs 21.5% IV fluid hydration, difference 0.4%; [-11.7 to 12.4], P = .95). There were no pulmonary aspirations in either group. Apneas and bradycardias were similar in each group. IV fluid hydration use was positively associated with intensive care unit admission (38.5% IV fluid hydration vs 19.9% nasogastric hydration; difference 18.6%, [5.1-32.1], P = .004); and use of ventilation support (27.7% IV fluid hydration vs 15.1% nasogastric hydration; difference 12.6 [0.3-23], P = .03). Fewer infants changed from nasogastric hydration to IV fluid hydration than from IV fluid hydration to nasogastric hydration (12.3% vs 47.7%; difference -35.4% [-49 to -22], P < .001). Nasogastric hydration can be used in the majority of young infants admitted with bronchiolitis. Nasogastric hydration and IV fluid hydration had similar rates of complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery.

    PubMed

    Yu, Jea H; Nguyen, Chuck; Gallemore, Esmeralda; Gallemore, Ron P

    2016-01-01

    Purpose . To report a new technique for anterior placement of tubes for glaucoma drainage devices to reduce the risk of tube erosions. Methods . Retrospective review of select cases of Ahmed Valve surgery combined with the novel method of a limbal-based scleral flap covered by a scleral patch graft to cover the tube at the entrance through the limbus. Intraoperative and postoperative illustrations are shown to highlight the method of tube placement. Results . In this retrospective case series, 3 patients are presented illustrating the technique. Two had neovascular glaucoma and one had primary open-angle glaucoma (POAG). On average, intraocular pressure was reduced from 39 ± 14 mmHg to 15 ± 2 mmHg and the number of glaucoma medications was reduced from 4 ± 1 to 0. Preoperative and most recent visual acuities were hand-motion (HM) and HM, 20/60 and 20/50, and 20/70 and 20/30, respectively. Conclusion . The combination of a limbal-based scleral flap with scleral patch graft to cover the tube with glaucoma drainage devices may be an effective means to reduce erosion and protect against endophthalmitis.

  20. Stability and recovery of DIFICID(®) (Fidaxomicin) 200-mg crushed tablet preparations from three delivery vehicles, and administration of an aqueous dispersion via nasogastric tube.

    PubMed

    Tousseeva, Anna; Jackson, J Derek; Redell, Mark; Henry, Teresa; Hui, Michael; Capurso, Shelley; DeRyke, C Andrew

    2014-12-01

    Fidaxomicin is approved for the treatment of adults with Clostridium difficile-associated diarrhea, many of whom have difficulty swallowing an intact tablet. The study objective was to evaluate the stability and recovery of crushed DIFICID(®) (fidaxomicin) 200-mg tablets dispersed in water, applesauce, or Ensure(®) brand liquid nutritional supplement, and to determine the recovery of fidaxomicin from the administration of an aqueous dispersion of a crushed DIFICID(®) tablet through a nasogastric (NG) tube. DIFICID(®) tablets were crushed and dispersed in water, applesauce, or Ensure(®). The stability and recovery of fidaxomicin were evaluated over 24 h in these vehicles. In a separate experiment, the ability to recover a full dose of fidaxomicin when administering as an aqueous dispersion through an NG tube was assessed. When DIFICID(®) tablets were crushed and dispersed in water, the active ingredient, fidaxomicin, was stable for up to 2 h at room temperature. Additionally, it was stable for up to 24 h in dispersions with applesauce or Ensure(®). Recovery of fidaxomicin after crushing and dispersing in any of the three vehicles studied ranged from 95 to 108 %, which is within the normal range of individual tablet variability. When crushed, dispersed in water, and administered through an NG tube, the average recovery of fidaxomicin was 96 %. Stability and recovery of fidaxomicin were confirmed when DIFICID(®) tablets were crushed and dispersed in water, applesauce, or Ensure(®). In addition, administration of an aqueous dispersion of a crushed tablet through an NG tube is supported by acceptable recovery of fidaxomicin.

  1. Unnecessary gastric decompression in distal elective bowel anastomoses in children: a randomized study.

    PubMed

    Davila-Perez, Roberto; Bracho-Blanchet, Eduardo; Tovilla-Mercado, Jose Manuel; Hernandez-Plata, Jose Alejandro; Reyes-Lopez, Alfonso; Nieto-Zermeño, Jaime

    2010-05-01

    The goal of this study was to investigate the role of nasogastric drainage in preventing postoperative complications in children with distal elective bowel anastomosis. Nasogastric drainage has been used as a routine measure after gastrointestinal surgery in children and adults to hasten bowel function, prevent postoperative complications, and shorten hospital stay. However, there has been no study that shows in a scientific manner the benefit of nasogastric drainage in children. We performed a clinical, controlled, randomized trial comprising 60 children who underwent distal elective bowel anastomoses and compared postoperative complications between a group with nasogastric tube in place (n = 29) and one without it (n = 31). Demographic data and diagnoses were comparable in both groups (P = NS). No anastomotic leaks or enterocutaneous fistulae were found in any patient. There were no significant differences between the two groups with respect to abdominal distension, infection, or hospital stay. Only one patient in the experimental group required placement of the nasogastric tube due to persistent abdominal distension (3.2%). The routine use of nasogastric drainage after distal elective intestinal surgery in children can be eliminated. Its use should depend on the individual patient's situation.

  2. Endotracheal tube placement by EMT-Basics in a rural EMS system.

    PubMed

    Pratt, Jeffrey C; Hirshberg, Alan J

    2005-01-01

    To evaluate the effectiveness of an intubation-training module and special-waiver project in which Emergency Medical Technician (EMT)-Basics were trained to perform endotracheal intubations in a rural community. This was a prospective observational study over a four-year period (July 1998 through May 2002) of all intubation attempts by EMT-Basics in the field. The authors observed intubation data, training methods, and quality-assurance methods of a special-waiver project agreed to by the State Department of Public Health to train and allow EMT-Basics to intubate patients. Data were from documentation unique to the project. Project documentation evaluated the placement and complication(s) of endotracheal tube (ETT) placement after arrival to the emergency department. An intubation attempt was defined as direct laryngoscopy. A successful attempt was defined as an appropriately sized ETT placed and secured in the trachea below the vocal cords and above the carina. Confirmation of placement in the field included accepted clinical methods and the use of qualitative colorimetric end-tidal carbon dioxide detectors. The EMT-Basics were trained using a paramedic curriculum, including operating room intubations on live adult patients. All patients were in either cardiopulmonary or respiratory arrest. Thirty-two intubations were performed by EMT-Basics. Thirty attempts were successful and two were unsuccessful (94%; 95% confidence interval [CI] 80-98%). Unsuccessful ETT placements were managed with accepted basic life support airway standards. There were no unrecognized esophageal ETT placements (0%; 95% CI 0-11%). This study demonstrated that with an intensive training program using selected highly motivated providers and close monitoring, a program of EMT-Basic ETT placement in a rural setting can achieve acceptable success rates in patients in cardiac or respiratory arrest.

  3. Association of a Proactive Swallowing Rehabilitation Program With Feeding Tube Placement in Patients Treated for Pharyngeal Cancer.

    PubMed

    Ajmani, Gaurav S; Nocon, Cheryl C; Brockstein, Bruce E; Campbell, Nicholas P; Kelly, Amy B; Allison, Jamie; Bhayani, Mihir K

    2018-04-19

    A proactive speech and language pathology (SLP) program is an important component of the multidisciplinary care of patients with head and neck squamous cell carcinoma (HNSCC). Swallowing rehabilitation can reduce the rate of feeding tube placement, thereby significantly improving quality of life. To evaluate the initiation of a proactive SLP rehabilitation program at a single institution and its association with rates of feeding tube placement and dietary intake in patients with HNSCC. Cohort study at a tertiary care and referral center for patients with HNSCC serving the northern Chicago region. Patients were treated for squamous cell carcinomas of the hypopharynx, oropharynx, and nasopharynx from 2004 to 2015 with radiation or chemoradiation therapy in the definitive or adjuvant setting. Patients who received less than 5000 cGy radiation or underwent reirradiation were excluded. A proactive SLP program for patients with HNSCC was initiated in 2011. Study cohorts were divided into 2 groups: 2004 through 2010 and 2011 through 2015. Primary outcome variables were SLP referral placement and timing of the referral. Secondary outcomes were feeding tube placement and ability to tolerate any oral intake. A total of 254 patients met inclusion criteria (135 before and 119 after implementation of SLP program; median age, 60 years [range, 14-94 years]; 77% male). With the initiation of a proactive SLP program, pretreatment evaluations increased from 29 (21.5%) to 70 (58.8%; risk ratio [RR], 2.74; 95% CI, 1.92-3.91), and rate of referral overall at any time increased from 60.0% to 79.8% (RR, 1.33; 95% CI, 1.13-1.57). Feeding tube placement rates decreased from 45.9% (n = 62) to 29.4% (n = 35; RR, 0.64; 95% CI, 0.46-0.89). Among patients receiving a swallow evaluation, feeding tube requirements were less frequent for those receiving a pretreatment evaluation (31 of 99 [31%]) than for those referred during (11 of 18 [61%]) or after (38 of 59 [64%]) treatment. The rate

  4. Gastric phytobezoars may be treated by nasogastric Coca-Cola lavage.

    PubMed

    Ladas, Spiros D; Triantafyllou, Konstantinos; Tzathas, Charalabos; Tassios, Pericles; Rokkas, Theodore; Raptis, Sotirios A

    2002-07-01

    Large gastric phytobezoars may occur in patients with gastric dysmotility disorders. Treatment options include dissolution with enzymes, endoscopic fragmentation with removal or aspiration, and surgery. We report our experience with nasogastric cola lavage therapy. Over an 8-year period, five consecutive patients were referred to our unit for endoscopic treatment of large gastric phytobezoars. They included one patient with lobectomy for lung cancer and four patients with diabetic gastroparesis. An initial attempt of endoscopic fragmentation and removal was unsuccessful. Patients were treated with 3 l of Coca-Cola nasogastric lavage over 12 h. Nasogastric lavage was very well tolerated by the patients. Complete phytobezoar dissolution was achieved in one session in all cases. There were no procedure-related complications. The dissolution of large gastric phytobezoars with cola nasogastric lavage is a safe, rapid and effective method. Patients may be treated in the medical ward, avoiding therapeutic endoscopy or surgery.

  5. Is short-term PEG-tube placement beneficial in acutely ill cognitively intact elderly patients? A proposed decision making algorithm

    PubMed Central

    Abraham, Rtika R; Girotra, Mohit; Wei, Jeanne Y.; Azhar, Gohar

    2014-01-01

    Aim Percutaneous Endoscopic Gastrostomy (PEG) tube is an important method of enteral feeding for patients who require temporary or long-term artificial nutritional support to prevent or correct disease-related malnutrition. However, there is paucity of data on the utility of short-term PEG tube placements in acute illnesses in cognitively intact elderly. Methods We present a series of seven, cognitively intact patients (age range = 72 to 93 years), who had PEG tubes placed for short periods. These patients were diagnosed with “failure to thrive” and were managed by placing a PEG tube temporarily for nutritional management. None of these patients had terminal illness or hospice eligibility and all of our patients were community dwellers. Results All our elderly patients experienced good outcomes in terms of their functional status and nutritional support. Conclusions Our series clearly supports the notion that short-term PEG tube placement in cognitively-intact elderly patients could be a successful strategy to support them during an episode of acute illness and to improve their nutritional deficits and survival. PMID:25109444

  6. Barbed suture material technique for wound closure and concomitant tube placement in uniportal VATS for pneumothorax

    PubMed Central

    2017-01-01

    Background Uniportal video-assisted thoracoscopic surgery (VATS) is an alternative modality for treatment of primary spontaneous pneumothorax (PSP) with its less invasiveness and acceptable surgical outcomes. However, a few reports have been introduced for wound management to achieve better cosmetic wound healing and for placement of the chest tube in uniportal VATS. Thus, we aimed to evaluate the feasibility of our novel method for wound closure and concomitant tube placement using continuous barbed suture material in uniportal VATS for PSP. Methods Between July 2012 and December 2015, consecutive 31 patients (22 males) underwent uniportal VATS to treat PSP. Bilateral approaches were performed in four patients, thus total 35 cases were enrolled. We divided them into two groups with one group of 17 (48.5%) cases (group A), using barbed absorbable wound closure device for knotless continuous wound closure and subsequent chest tube anchoring, and the other group of 18 (51.4%) cases (group B), using conventional suture anchoring after skin closure using absorbable suture device. Postoperative surgical outcomes were compared to assess the feasibility of this technique. Results Demographic data demonstrate no significant difference in both groups. There was no significant difference in length of hospital stay (3.7±1.2 vs. 4.1±1.2 days, P=0.267) and in median chest tube indwelling time (2.4±0.9 vs. 3.1±1.2 days, P=0.066), respectively. Operation time in group A was shorter than in group B but there was no significant difference (41.7±11.8 vs. 45.6±16.0 minutes, P=0.415). There was neither conversion to two or three port VATS in all cases. In group A, all chest tubes were removed with concomitant sealing the tube removal site by pulling the thread. Residual knots do not exist that stitch out procedure is not required. There was no wound complication in both groups during the median follow-up period of 18 months. Conclusions Knotless, barbed suture material technique

  7. Middle finger length-based tracheal intubation depth improves the rate of appropriate tube placement in children.

    PubMed

    Zhou, Qing-he; Xiao, Wang-pin; Zhou, Hong-mei

    2015-11-01

    It is challenging for anesthetists to determine the optimal tracheal intubation depth in children. We hypothesize that a measure three times the length of the middle finger can be used for predicting tracheal tube depth in children. Eighty-six children (4-14 years of age) were included in this study. After the children were anesthetized, a fiberoptic bronchoscope (FOB) was inserted into the trachea, the lengths from the upper incisor teeth to carina and vocal cords were measured, and a suitably sized cuffed tracheal tube was inserted into the trachea. Age-based and middle finger length-based formulas were used to determine the tracheal intubation depth. All 86 children enrolled were included in this study. Compared with the age-based intubation, the rate of appropriate tube placement was higher for middle finger length-based intubation (88.37% vs 66.28%, P = 0.001). The proximal intubation rate was lower in middle finger length-based intubation (4.65% vs 32.56%, P < 0.001). There was only weak evidence for a difference in the distal intubation rate between the two methods (6.97% vs 1.16%, P = 0.054). The correlation coefficient between middle finger length and optimal tracheal tube depth was larger than that between age and optimal tracheal tube depth (0.883 vs 0.845). Our data indicate that the appropriate tube placement rate can be improved by using three times the middle finger length as the tracheal intubation depth in children. © 2015 John Wiley & Sons Ltd.

  8. Benefits of postpyloric enteral access placement by a nutrition support dietitian.

    PubMed

    Jimenez, L Lee; Ramage, James E

    2004-10-01

    Although enteral nutrition is considered the preferred strategy for nutrition support, it is often precluded by nasogastric feeding intolerance or the inability to place feeding access into the postpyloric position. In an effort to improve enteral nutrition (EN) outcomes at our institution, the nutrition support dietitian (NSD) began placing postpyloric feeding tubes (PPFT) in intensive care unit patients. Intensive care unit patients who received blind, bedside PPFT placements by the NSD (n = 18) were compared with a concurrent age- and diagnosis-matched control group that received standard nutritional care without NSD intervention (n = 18). Interruption of EN infusion, appropriateness of parenteral nutrition (PN) prescription (based on American Society of Parenteral and Enteral Nutrition guidelines), and incidence of ventilator-associated pneumonia (VAP), as defined by the American College of Chest Physicians practice guidelines, were determined in each group. The NSD was successful in positioning the PPFT at or distal to the third portion of the duodenum in 83% of attempts. The PPFT group demonstrated no interruption of enteral feeding compared with 56% in the control group (p < .01) and required 1 (6%) PN initiation in contrast to 8 (44%) in the control group (p < .01). There was a trend toward reduced VAP in the PPFT group (6% vs 28%, p = .07). Of the PN initiations in the control group, 88% were deemed to be potentially avoidable; 6 of 8 PNs were initiated because of gastric residuals. Enteral nutrition facilitated by NSD placement of postpyloric feeding access is associated with improved tube feeding tolerance and reduced PN use. Further studies are needed to evaluate a possible effect of postpyloric feeding on the incidence of VAP.

  9. Residual hemothorax after chest tube placement correlates with increased risk of empyema following traumatic injury

    PubMed Central

    Karmy-Jones, Riyad; Holevar, Michele; Sullivan, Ryan J; Fleisig, Ani; Jurkovich, Gregory J

    2008-01-01

    BACKGROUND: Empyema complicates tube thoracostomy following trauma in up to 10% of cases. Studies of potential risk factors of empyema have included use of antibiotics, site of injury and technique of chest tube placement. Residual fluid has also been cited as a risk factor for empyema, although the imaging technique to identify this varies. OBJECTIVE: To determine whether residual hemothorax detected by chest x-ray (CXR) after one or more initial chest tubes predicts an increased risk of empyema. METHODS: A study of patients admitted to two level I trauma centres between January 7, 2004, and December 31, 2004, was conducted. All patients who received a chest tube in the emergency department, did not undergo thoracotomy within 24 h, and survived more than two days were followed. Empyema was defined as a pleural effusion with positive cultures, and a ratio of pleural fluid lactate dehydrogenase to serum lactate dehydrogenase greater than 0.6 in the setting of elevated leukocyte count and fever. Factors analyzed included the presence of retained hemothorax on CXR after the most recent tube placement in the emergency room, age, mechanism of injury and injury severity score. RESULTS: A total of 102 patients met the criteria. Nine patients (9%) developed empyema: seven of 21 patients (33%) with residual hemothorax developed empyema versus two of 81 patients (2%) without residual hemothorax developed empyema (P=0.001). Injury severity score was significantly higher in those who developed empyema (31.4±26) versus those who did not (22.6±13; P=0.03). CONCLUSIONS: The presence of residual hemothorax detected by CXR after tube thoracostomy should prompt further efforts, including thoracoscopy, to drain it. With increasing injury severity, there may be increased benefit in terms of reducing empyema with this approach. PMID:18716687

  10. Repair of an aberrant subclavian arterioesophageal fistula following esophageal stent placement

    PubMed Central

    Hosn, Maen Aboul; Haddad, Fady; El-Merhi, Fadi; Safadi, Bassem; Hallal, Ali

    2014-01-01

    A fistula formation between the esophagus and an aberrant right subclavian artery is a rare but fatal complication that has been mostly described in the setting of prolonged nasogastric intubation and foreign body erosion. We report a case of a young morbidly obese patient who underwent sleeve gastrectomy that was complicated by a postoperative leak at the level of the gastroesophageal junction. A covered esophageal stent was placed endoscopically to treat the leak. The patient developed massive upper gastrointestinal bleeding secondary to the erosion of the stent into an aberrant retroesophageal right subclavian artery twelve days after stent placement. She was ultimately treated by endovascular stenting of the aberrant right subclavian artery followed by thoracotomy and esophageal repair over a T-tube. This case report highlights the multidisciplinary approach needed to diagnose and manage such a devastating complication. It also emphasizes the need for imaging studies prior to stent deployment to delineate the vascular anatomy and rule out the possibility of such an anomaly in view of the growing popularity of esophageal stents, especially in the setting of a leak. PMID:24976906

  11. Timing of Tympanostomy Tube Placement and Efficacy of Palatoplasty Technique on the Resolution of Chronic Otitis Media: A Cross-sectional Analysis

    PubMed Central

    Brgoch, M. S.; Dodson, K. M.; Kim, T. C.; Kim, D. M.; Rhodes, J. L.

    2015-01-01

    Background: Chronic otitis media with effusion is a persistent complication essentially universal in children with cleft palate. The prevalence of chronic otitis media with effusion is hypothesized to be a result of Eustachian tube dysfunction secondary to the anomalous insertion of the palatal musculature. This study was designed to evaluate the timing of tympanostomy tube placement and the effect of primary palatoplasty technique on the recovery of Eustachian tube function and resolution of chronic otitis media with effusion. Methods: We performed a retrospective, cross-sectional analysis of the previous 99 consecutive patients who underwent a palatoplasty at our institution. Variables included timing of initial tympanostomy tube placement, palatoplasty technique, cleft type, and gender. These were then evaluated to assess their impact on the resolution of chronic otitis media with effusion. Resolution was established as an inverse function of the number of tympanostomy tubes placed in correlation with available audiometric/tympanographic data. For all models, a generalized linear mixed model was applied using a Poisson distribution and a log-link function where the outcome variable was the total number of tympanostomy tubes. For all tests, a P = .05 level of significance was used. Results: Of 99 palatoplasties performed, 94 patients were included in the study. Ninety-one percent of patients had documented chronic otitis media with effusion at the time of palatoplasty. Forty-four percent underwent straight-line repair with aggressive intravelar veloplasty, 36% had Furlow double z-plasty, 20% had straight-line repair without intravelar veloplasty. There was a statistically significant difference (F2,83 = 5.36, P = .0065) between the 3 types of repair. The mean number of tubes placed was 0.6000 ± 0.1225, 0.8519 ± 0.1776, and 1.4737 ± 0.2785 for intravelar veloplasty, Furlow double z-plasty, and straight line without intravelar veloplasty, respectively . With

  12. Optimization of Ultrasound Transducer Positioning for Endotracheal Tube Placement Confirmation in Cadaveric Model.

    PubMed

    Lonchena, Tiffany; So, Sokpoleak; Ibinson, James; Roolf, Peter; Orebaugh, Steven L

    2017-02-01

    Sonography has been suggested as a possible means of endotracheal tube (ETT) placement confirmation. However, optimum ultrasound transducer placement has not been established. Using a cadaveric model, ETT placement by the sonographic appearance at the thyroid cartilage, cricoid cartilage, and suprasternal notch in the upper airway was assessed to determine which ultrasound transducer placement offered the most optimal images for ETT confirmation in the airway. One provider intubated 5 cadavers, with the ultrasound transducer at each of the 3 levels, for a total of 30 intubations per specimen, while 2 providers assigned a visual score of 1 (subtle), 2 (clear), or 3 (pronounced) to each sonogram of the ETT in the airway. At the level of the thyroid cartilage, tracheal intubation was detected at a rate of 40%, with a median visualization scale of 1 (subtle movement). At the level of the cricoid cartilage, the visualization scale improved to a median of 2 (clear movement), with a 70% intubation detection rate. At the level of the suprasternal notch, 100% of the tracheal intubations were visualized on sonography, with a median score of 3 (pronounced movement). In comparing sonographic detection of ETT placement at 3 levels of the upper airway in a cadaveric model, our results clearly indicate that visualization was superior at the level of the suprasternal notch, with 100% of intubations detected with the best visualization scores. © 2017 by the American Institute of Ultrasound in Medicine.

  13. Patterns of prophylactic gastrostomy tube placement in head and neck cancer patients: a consideration of the significance of social support and practice variation.

    PubMed

    Locher, Julie L; Bonner, James A; Carroll, William R; Caudell, Jimmy J; Allison, Jeroan J; Kilgore, Meredith L; Ritchie, Christine S; Tajeu, Gabriel S; Yuan, Ya; Roth, David L

    2013-08-01

    The purpose of this study was to examine factors associated with prophylactic placement of feeding tubes in head and neck cancer patients receiving radiation therapy as a part of treatment using multilevel models that account for patient-, physician-, and institution-level sources of variation. A retrospective analysis using binary logistic regression and hierarchical linear models was run to evaluate independent predictors of prophylactic feeding tube placement. Surveillance, Epidemiology, and End Results-Medicare data were used. Head and neck cancer patients diagnosed with locoregionally advanced stage disease from 2000 to 2005 were included in this study (N = 8,306). Across all models, prophylactic gastrostomy tube placement was found to be more likely in patients who had cancer of the larynx or oropharynx compared with those with cancer of the nasopharynx or oral cavity; who had regional instead of local cancer; who did not receive surgery as a part of treatment, but did receive chemotherapy; and who were divorced, separated, or widowed. Additionally, although practice variation was observed to occur, its overall contribution in predicting prophylactic gastrostomy tube placement was minimal. As health care enters an era of patient-centered care, further investigation of the potential role of social support (or lack of social support) in influencing treatment decisions of head and neck cancer patients and providers is warranted. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Nasoenteral feeding tube placement by nurses using an electromagnetic guidance system (with video).

    PubMed

    Mathus-Vliegen, Elisabeth M H; Duflou, Ann; Spanier, Marcel B W; Fockens, Paul

    2010-04-01

    The early institution of feeding in patients who need postpyloric feeding tubes is often hampered by a limited availability of endoscopists experienced in safe tube positioning. To test the feasibility of having nurses place postpyloric feeding tubes by using a universal path finding system device. Prospective study. Academic hospital. The success rate and learning curve of a senior nurse placing postpyloric feeding tubes in 50 patients was studied, followed by a study in 160 patients on the success rates and learning curves of 4 inexperienced nurses instructed by the senior nurse. Finally, the success rate of postpyloric feeding tube placement by the senior nurse in 50 critically ill patients was investigated. Postpyloric feeding tube positioning by nurses using an electromagnetic universal path-finding system device enabling them to follow the path of the tip of the feeding tube on a monitor screen. Success was defined by postpyloric positioning of the feeding tube. The ultimate aim was to reach at least the duodenojejunal flexure. In the first part, the senior nurse was successful in 72% of cases. There was a clear learning curve. In the second part, the 4 newly instructed nurses had a success rate of 89.4% without an evident learning curve. In the third part, successful feeding tube positioning was achieved in 78% of critically ill patients. Of the 217 successfully positioned tubes, 74% reached at least the duodenojejunal flexure. In half of the unsuccessful cases, an explanation for the failure was found at endoscopy. No complications were seen. The generalization to less-specialized hospitals should be investigated. Postpyloric positioning of feeding tubes by nurses at the bedside without endoscopy is feasible and safe. Nurses may take over some of the tasks of doctors in a time of high endoscopic needs. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  15. Nasogastric hydration versus intravenous hydration for infants with bronchiolitis: a randomised trial.

    PubMed

    Oakley, Ed; Borland, Meredith; Neutze, Jocelyn; Acworth, Jason; Krieser, David; Dalziel, Stuart; Davidson, Andrew; Donath, Susan; Jachno, Kim; South, Mike; Theophilos, Theane; Babl, Franz E

    2013-04-01

    Bronchiolitis is the most common lower respiratory tract infection in infants and the leading cause of hospital admission. Hydration is a mainstay of treatment, but insufficient evidence exists to guide clinical practice. We aimed to assess whether intravenous hydration or nasogastric hydration is better for treatment of infants. In this multicentre, open, randomised trial, we enrolled infants aged 2-12 months admitted to hospitals in Australia and New Zealand with a clinical diagnosis of bronchiolitis during three bronchiolitis seasons (April 1-Oct 31, in 2009, 2010, and 2011). We randomly allocated infants to nasogastric hydration or intravenous hydration by use of a computer-generated sequence and opaque sealed envelopes, with three randomly assigned block sizes and stratified by hospital site and age group (2-<6 months vs 6-12 months). The primary outcome was length of hospital stay, assessed in all randomly assigned infants. Secondary outcomes included rates of intensive-care unit admission, adverse events, and success of insertion. This trial is registered with the Australian and New Zealand clinical trials registry, ACTRN12605000033640. Mean length of stay for 381 infants assigned nasogastric hydration was 86·6 h (SD 58·9) compared with 82·2 h (58·8) for 378 infants assigned intravenous hydration (absolute difference 4·5 h [95% CI -3·9 to 12·9]; p=0·30). Rates of admission to intensive-care units, need for ventilatory support, and adverse events did not differ between groups. At randomisation, seven infants assigned nasogastric hydration were switched to intravenous hydration and 56 infants assigned intravenous hydration were switched to nasogastric hydration because the study-assigned method was unable to be inserted. For those infants who had data available for successful insertion, 275 (85%) of 323 infants in the nasogastric hydration group and 165 (56%) of 294 infants in the intravenous hydration group required only one attempt for successful

  16. Failure of nasogastric omeprazole suspension in pediatric intensive care patients.

    PubMed

    Haizlip, Julie A; Lugo, Ralph A; Cash, Jared J; Vernon, Donald D

    2005-03-01

    To determine the efficacy of nasogastric administration of omeprazole suspension in raising the gastric pH >4 in critically ill pediatric patients and to determine the most appropriate dosing regimen for this indication. Open-label pharmacodynamic study. Twenty-six bed tertiary-care pediatric intensive care unit. Mechanically ventilated children aged 1-18 yrs with an additional risk factor for stress ulcer formation. Continuous gastric pH monitoring was performed during administration and dose titration of omeprazole suspension to achieve the goal of gastric pH >4 for greater than 75% of the dosing interval. Data were collected from 18 patients. Subjects were categorized based on the pharmacologic response to nasogastric administration of 1 mg/kg omeprazole suspension (maximum 20 mg) as rapid (n = 9), late (n = 5), and nonresponders (n = 4). Rapid responders required 0.72 mg/kg per day omeprazole suspension to achieve adequate gastric pH elevation for stress ulcer prophylaxis. Late responders required 1.58 mg/kg per day. Nonresponders did not achieve adequate elevation of gastric pH for stress ulcer prophylaxis. Nasogastric administration of omeprazole suspension has variable efficacy in critically ill pediatric patients. Half of the studied subjects either required significant dose titrations to achieve gastric acid suppression or did not respond to nasogastric administration of omeprazole suspension.

  17. A technique for open trocar placement in laparoscopic surgery using the umbilical cicatrix tube.

    PubMed

    Lal, Pawanindra; Sharma, R; Chander, R; Ramteke, V K

    2002-09-01

    Increasingly the open method for placement of the initial or first trocar is replacing the conventional technique with the Veress needle. Indeed, it is preferred because it affords peritoneal access under direct vision. A number of methods have been described in the literature using a variety of approaches and different instruments. We describe a method of open trocar placement in the supra- or subumbilical region that follows a stepwise procedure and employs specific instruments sequentially, while utilizing the umbilical cicatrix pillar or tube. This technique has been done in 525 cases with no complications or port site hernias. This is a simple technique that is safe and easy to learn. It can be performed rapidly and is a reliable method for the insertion of the first port under vision.

  18. Treatment of spontaneous esophageal rupture with transnasal thoracic drainage and temporary esophageal stent and jejunal feeding tube placement.

    PubMed

    Wu, Gang; Zhao, Yan Shi; Fang, Yi; Qi, Yu; Li, Xiangnan; Jiao, Dechao; Ren, Kewei; Han, Xinwei

    2017-01-01

    Spontaneous rupture of the esophagus is a rare but life-threatening thoracic emergency, with high rates of clinical misdiagnosis and mortality. This article summarizes our experience in the treatment of spontaneous esophageal rupture with transnasal thoracic drainage and temporary esophageal stent and jejunal feeding tube placement. We retrospectively assessed the medical records of 19 patients with spontaneous esophageal rupture treated using our intervention protocol. Patients received local anesthesia and sedation prior to undergoing transnasal drainage catheter placement into the thoracic abscess cavity, followed by temporary esophageal stent and jejunal feeding tube placement. After the operation, abscess lavage, nutritional support, and anti-inflammatory treatment were given. The transnasal thoracic drainage catheter, esophageal stent, and feeding tube were removed after the healing of the abscess cavity. In all, 19 covered esophageal stents were placed in 19 patients with spontaneous esophageal rupture. All operations were technically successful. After an average of 84.06 days, the stents were successfully removed from 17 patients. No cases of massive hemorrhage, esophageal rupture, or other complications occurred during stent removal. An 82-year-old patient died of heart failure 2 months after the operation. One patient died of sudden massive hematemesis and hematochezia 55 days after the operation. In one patient, the esophageal injury failed to heal completely. Our treatment protocol is simple, minimally invasive, and efficacious and may be an alternative for patients who are not candidates for surgery, have a high risk of postoperative complications, or wish to undergo minimally invasive surgery. Therapeutic study, level V.

  19. Mortality after nasogastric tube feeding initiation in long-term care elderly with oropharyngeal dysphagia--the contribution of refeeding syndrome.

    PubMed

    Lubart, Emilia; Leibovitz, Arthur; Dror, Yosef; Katz, Elena; Segal, Refael

    2009-01-01

    The refeeding syndrome (RS) is an underappreciated but clinically important entity characterized by acute electrolyte abnormalities, mainly hypophosphatemia, fluid retention and dysfunction of various organs and systems, which can result in significant morbidity and occasionally death. To examine the incidence of death cases and death causes following nasogastric tube (NGT) feeding initiation in frail elderly with particular reference to RS. Forty patients with feeding problems for at least 72 h before restarting of alimentation by NGT were included. Excluded were those in any critical clinical situation. Clinical parameters and nutritional assessment were recorded before and after refeeding. Blood samples were taken before, daily for the first 3 days and 1 week after refeeding initiation. During the 1st week of refeeding, 9 patients (22.5%) died and within 1 month 10 more, summing to 47.5%. Most deaths were due to infectious causes [15 out of 19, (79%)]; some were due to no obvious reason [4 out of 19, (21%)]. Significant electrolyte changes were observed in the 2-3 days following refeeding. Significant were the decreases in phosphorus and elevations in potassium and lymphocytes (day 7). We found no correlations between the severity of decreases in levels of phosphorus and mortality. Mortality after NGT feeding initiation was high, mainly due to infectious complications. However, in a considerable number of patients hypophosphatemia was noted, suggesting that RS could be a contributory factor of mortality. Since this is a treatable condition, more attention should be paid to detecting and coping with this problem. Copyright 2009 S. Karger AG, Basel.

  20. Continuous nasogastric tube feeding: monitoring by combined use of refractometry and traditional gastric residual volumes.

    PubMed

    Chang, W-K; McClave, S-A; Chao, Y-C

    2004-02-01

    Traditional use of gastric residual volumes (GRVs) is insensitive and cannot distinguish retained enteral formula from the large volume of endogenous secretions. We designed this prospective study to determine whether refractometry and Brix value (BV) measurements could be used to monitor gastric emptying and tolerance in patients receiving continuous enteral feeding. Thirty-six patients on continuous nasogastric tube feeding were divided into two groups; patients with lower GRVs (<75 ml) in Group 1, patients with higher GRVs (>75 ml) in Group 2. Upon entry, all gastric contents were aspirated, the volume was recorded (Asp GRV), BV measurements were made by refractometry, and then the contents were reinstilled but diluted with 30 ml additional water. Finally, a small amount was reaspirated and repeat BV measurements were made. Three hours later, the entire procedure was repeated a second time. The BV ratio, calculated (Cal) GRV, and volume of formula remaining were calculated by derived equations. Mean BV ratios were significantly higher for those patients in Group 2 compared to those in Group 1. All but one of the 22 patients (95%) in Group 1 had a volume of formula remaining in the stomach estimated on both measurements to be less than the hourly infusion rate (all these patients had BV ratios <70%). In contrast, six of the 14 patients in Group 2 (43%) on both measurements were estimated to have volumes of formula remaining that were greater than the hourly infusion rate (all these patients had BV ratios >70%). Three of the Group 2 patients (21%) whose initial measurement showed evidence for retention of formula, improved on repeat follow-up measurement assuring adequate gastric emptying. The remaining five patients from Group 2 (35%) had a volume of formula remaining that was less than the hourly infusion rate on both measurements. The pattern of Asp GRVs and serial pre- and post-dilution BVs failed to differentiate these patients in Group 2 with potential

  1. Experience in Bedside Placement, Clinical Validity, and Cost-Efficacy of a Self-Propelled Nasojejunal Feeding Tube

    PubMed Central

    Puiggròs, Carolina; Molinos, Rosa; Ortiz, M. Dolors; Ribas, Montserrat; Romero, Carlos; Vázquez, Concepcion; Segurola, Hegoi; Burgos, Rosa

    2015-01-01

    Background: The procedures needed to insert nasojejunal tubes (NJTs) are often invasive or uncomfortable for the patient and require hospital resources. The objectives of this study were to describe our experience in inserting a self-propelling NJT with distal pigtail end and evaluate clinical validity and cost efficacy of this enteral nutrition (EN) approach compared with parenteral nutrition (PN). Materials and Methods: Prospective study from July 2009 to December 2010, including hospitalized noncritical patients who required short-term jejunal EN. The tubes were inserted at bedside, using intravenous erythromycin as a prokinetic drug. Positioning was considered correct when the distal end was beyond the ligament of Treitz. Migration failure was considered when the tube was not positioned into the jejunum within 48 hours postinsertion. Results: Fifty-six insertions were recorded in 47 patients, most frequently in severe acute pancreatitis (69.6%). The migration rates at 18 and 48 hours postinsertion were 73.2% and 82.1%, respectively. There was migration failure in 8.9% of cases, and 8.9% were classified null (the tube was no longer in the gastrointestinal tract at 18 hours). There were no reported or observed complications. The mean duration of the EN was 12 ± 10.8 days. Five different types of EN formula were used. The total study cost was 53.9% lower compared with using PN in all patients. Conclusions: Our study demonstrated that bedside insertion of a self-propelling NJT is a safe, cost-effective, and successful technique for postpyloric enteral feeding in at least 73% of the patients, and only 18% of patients could eventually need other placement techniques. It can avoid the need for more aggressive or expensive placement techniques or even PN if we cannot achieve enteral access. PMID:26214512

  2. Comparison of laparoscopic jejunostomy tube to percutaneous endoscopic gastrostomy tube with jejunal extension: long-term durability and nutritional outcomes.

    PubMed

    Haskins, Ivy N; Strong, Andrew T; Baginsky, Mary; Sharma, Gautam; Karafa, Matthew; Ponsky, Jeffrey L; Rodriguez, John H; Kroh, Matthew D

    2018-05-01

    Enteral access through the jejunum is indicated when patients cannot tolerate oral intake or gastric feeding. While multiple approaches for feeding jejunal access exist, few studies have compared the efficacy of these techniques. The purpose of this study was to investigate the long-term durability, re-intervention rates, and nutritional outcomes following percutaneous endoscopic gastrostomy tubes with jejunal extension tubes (PEG-JET) versus laparoscopic jejunostomy tubes (j-tubes). Retrospective chart review was performed on all patients who underwent PEG-JET or laparoscopic jejunostomy tube placement from January 2005 through December 2015 at our institution. Thirty-day and long-term outcomes were compared between the two groups. A total of 105 patients underwent PEG-JET and 307 patients underwent laparoscopic j-tube placement during the defined study period. In terms of 30-day outcomes, patients who underwent PEG-JET placement were significantly more likely to experience a tube dislodgement event (p = 0.005) and undergo a re-intervention (p < 0.001). Patients who had a laparoscopic j-tube placed were significantly more likely to meet their enteral feeding goals (p = 0.002) and less likely to require nutritional supplementation with total parenteral nutrition (TPN) (p < 0.001). With regard to long-term outcomes, patients who underwent PEG-JET placement were significantly more likely to experience tube occlusion (p < 0.001) and require an endoscopic or surgical tube re-intervention (p < 0.001). Patients who underwent laparoscopic j-tube placement were significantly more likely to experience a tube site leak (p = 0.015) but were less likely to require nutritional supplementation with TPN (p = 0.001). Laparoscopic jejunostomy tubes provide more durable long-term enteral access compared to PEG-JET. Consideration should be given to laparoscopic jejunostomy tube placement in eligible patients who cannot tolerate oral intake or gastric

  3. Quality Improvement Initiative to Increase the Use of Nasogastric Hydration in Infants With Bronchiolitis.

    PubMed

    Srinivasan, Mythili; Pruitt, Cassandra; Casey, Erin; Dhaliwal, Keerat; DeSanto, Cori; Markus, Richard; Rosen, Ayelet

    2017-08-01

    Intravenous (IV) hydration is used primarily in children with bronchiolitis at our institution. Because nasogastric (NG) hydration can provide better nutrition, the goal of our quality improvement (QI) initiative was to increase the rate of NG hydration in eligible children 1 to 23 months old with bronchiolitis by 20% over 6 months. We used Plan-Do-Study-Act cycles to increase the use of NG hydration in eligible children. Interventions included educational and system-based changes and sharing parental feedback with providers. Chart reviews were performed to identify the rates of NG hydration, which were plotted over time in a statistical process control p chart. The balancing measure was the rate of complications in children with NG versus IV hydration. Two hundred and ninety-three children who were hospitalized with bronchiolitis needed supplemental hydration during the QI initiative (January 2016-April 2016). Ninety-one children were candidates for NG hydration, and 53 (58%) received NG hydration. The rates of NG hydration increased from a baseline of 0% pre-QI bronchiolitis season (January 2015-April 2015) to 58% during the initiative. There was no aspiration and no accidental placement of the NG tube into a child's airway. Nine patients (17%) in the NG group had a progression of disease requiring nil per os status, and 6 of these were transferred to the PICU whereas none of those in the IV group were transferred to the PICU. Post-QI initiative, the majority of nurses (63%) and physicians (95%) stated that they are more likely to consider NG hydration in children with bronchiolitis. We successfully increased the rates of NG hydration in eligible children with bronchiolitis by using educational and system-based interventions. Copyright © 2017 by the American Academy of Pediatrics.

  4. Comparison of intraoperative versus delayed enteral feeding tube placement in patients undergoing a Whipple procedure.

    PubMed

    Scaife, Courtney L; Hewitt, Kelly C; Mone, Mary C; Hansen, Heidi J; Nelson, Edward T; Mulvihill, Sean J

    2014-01-01

    The intraoperative placement of an enteral feeding tube (FT) during pancreaticoduodenectomy (PD) is based on the surgeon's perception of need for postoperative nutrition. Published preoperative risk factors predicting postoperative morbidity may be used to predict FT need and associated intraoperative placement. A retrospective review of patients who underwent PD during 2005-2011 was performed by querying the National Surgical Quality Improvement Program (NSQIP) database with specific procedure codes. Patients were categorized based on how many of 10 possible preoperative risk factors they demonstrated. Groups of patients with scores of ≤ 1 (low) and ≥ 2 (high), respectively, were compared for FT need, length of stay (LoS) and organ space surgical site infections (SSIs). Of 138 PD patients, 82 did not have an FT placed intraoperatively, and, of those, 16 (19.5%) required delayed FT placement. High-risk patients were more likely to require a delayed FT (29.3%) compared with low-risk patients (9.8%) (P = 0.026). The 16 patients who required a delayed FT had a median LoS of 15.5 days, whereas the 66 patients who did not require an FT had a median LoS of 8 days (P < 0.001). In this analysis, subjects considered as high-risk patients were more likely to require an FT than low-risk patients. Assessment of preoperative risk factors may improve decision making for selective intraoperative FT placement. © 2013 International Hepato-Pancreato-Biliary Association.

  5. Survival times with and without tube feeding in patients with dementia or psychiatric diseases in Japan.

    PubMed

    Takayama, Keiko; Hirayama, Keisuke; Hirao, Akihiko; Kondo, Keiko; Hayashi, Hideki; Kadota, Koichi; Asaba, Hiroyuki; Ishizu, Hideki; Nakata, Kenji; Kurisu, Kairi; Oshima, Etsuko; Yokota, Osamu; Yamada, Norihito; Terada, Seishi

    2017-11-01

    It is widely supposed that there has been no evidence of increased survival in patients with advanced dementia receiving enteral tube feeding. However, more than a few studies have reported no harmful outcome from tube feeding in dementia patients compared to in patients without dementia. This was a retrospective study. Nine psychiatric hospitals in Okayama Prefecture participated in this survey. All inpatients fulfilling the entry criteria were evaluated. All subjects suffered from difficulty with oral intake. Attending physicians thought that the patients could not live without long-term artificial nutrition. The physicians decided whether to make use of long-term artificial nutrition between January 2012 and December 2014. We evaluated 185 patients. Their mean age was 76.6 ± 11.4 years. Of all subjects, patients with probable Alzheimer's disease (n = 78) formed the biggest group, schizophrenia patients (n = 44) the second, and those with vascular dementia (n = 30) the third. The median survival times were 711 days for patients with tube feeding and 61 days for patients without tube feeding. In a comparison different types of tube feeding, median survival times were 611 days for patients with a nasogastric tube and more than 1000 days for those with a percutaneous endoscopic gastrostomy tube. Patients with tube feeding survived longer than those without tube feeding, even among dementia patients. This study suggests that enteral nutrition for patients with dementia prolongs survival. Additionally, percutaneous endoscopic gastrostomy tube feeding may be safer than nasogastric tube feeding among patients in psychiatric hospitals. © 2017 Japanese Psychogeriatric Society.

  6. Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system

    PubMed Central

    Changela, Kinesh; Culliford, Andrea; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2015-01-01

    Objectives: The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. Method: In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. Results: A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ± 20.57 days. A limitation of this study was that there was no control group. Conclusions: OTSC application is a safe and effective endoscopic approach for the closure of persistent GC fistulae secondary to a complication of PEG tube placement. PMID:26136836

  7. Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system.

    PubMed

    Singhal, Shashideep; Changela, Kinesh; Culliford, Andrea; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2015-07-01

    The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ± 20.57 days. A limitation of this study was that there was no control group. OTSC application is a safe and effective endoscopic approach for the closure of persistent GC fistulae secondary to a complication of PEG tube placement.

  8. [How to do - the chest tube drainage].

    PubMed

    Klopp, Michael; Hoffmann, Hans; Dienemann, Hendrik

    2015-03-01

    A chest tube is used to drain the contents of the pleural space to reconstitute the physiologic pressures within the pleural space and to allow the lungs to fully expand. Indications for chest tube placement include pneumothorax, hemothorax, pleural effusion, pleural empyema, and major thoracic surgery. The most appropriate site for chest tube placement is the 4th or 5th intercostal space in the mid- or anterior- axillary line. Attention to technique in placing the chest tube is vital to avoid complications from the procedure. Applying the step-by-step technique presented, placement of a chest tube is a quick and safe procedure. Complications - frequently occurring when the tube is inserted with a steel trocar - include hemothorax, dislocation, lung lacerations, and injury to organs in the thoracic or abdominal cavity." © Georg Thieme Verlag KG Stuttgart · New York.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heberlein, Wolf E., E-mail: weheberlein@uams.edu; Goodwin, Whitney J.; Wood, Clint E.

    Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncturemore » of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.« less

  10. Single endoscopist-performed percutaneous endoscopic gastrostomy tube placement

    PubMed Central

    Erdogan, Askin

    2013-01-01

    AIM: To investigate whether single endoscopist-performed percutaneous endoscopic gastrostomy (PEG) is safe and to compare the complications of PEG with those reported in the literature. METHODS: Patients who underwent PEG placement between June 2001 and August 2011 at the Baskent University Alanya Teaching and Research Center were evaluated retrospectively. Patients whose PEG was placed for the first time by a single endoscopist were enrolled in the study. PEG was performed using the pull method. All of the patients were evaluated for their indications for PEG, major and minor complications resulting from PEG, nutritional status, C-reactive protein (CRP) levels and the use of antibiotic treatment or antibiotic prophylaxis prior to PEG. Comorbidities, rates, time and reasons for mortality were also evaluated. The reasons for PEG removal and PEG duration were also investigated. RESULTS: Sixty-two patients underwent the PEG procedure for the first time during this study. Eight patients who underwent PEG placement by 2 endoscopists were not enrolled in the study. A total of 54 patients were investigated. The patients’ mean age was 69.9 years. The most common indication for PEG was cerebral infarct, which occurred in approximately two-thirds of the patients. The mean albumin level was 3.04 ± 0.7 g/dL, and 76.2% of the patients’ albumin levels were below the normal values. The mean CRP level was high in 90.6% of patients prior to the procedure. Approximately two-thirds of the patients received antibiotics for either prophylaxis or treatment for infections prior to the PEG procedure. Mortality was not related to the procedure in any of the patients. Buried bumper syndrome was the only major complication, and it occurred in the third year. In such case, the PEG was removed and a new PEG tube was placed via surgery. Eight patients (15.1%) experienced minor complications, 6 (11.1%) of which were wound infections. All wound infections except one recovered with antibiotic

  11. Single endoscopist-performed percutaneous endoscopic gastrostomy tube placement.

    PubMed

    Erdogan, Askin

    2013-07-14

    To investigate whether single endoscopist-performed percutaneous endoscopic gastrostomy (PEG) is safe and to compare the complications of PEG with those reported in the literature. Patients who underwent PEG placement between June 2001 and August 2011 at the Baskent University Alanya Teaching and Research Center were evaluated retrospectively. Patients whose PEG was placed for the first time by a single endoscopist were enrolled in the study. PEG was performed using the pull method. All of the patients were evaluated for their indications for PEG, major and minor complications resulting from PEG, nutritional status, C-reactive protein (CRP) levels and the use of antibiotic treatment or antibiotic prophylaxis prior to PEG. Comorbidities, rates, time and reasons for mortality were also evaluated. The reasons for PEG removal and PEG duration were also investigated. Sixty-two patients underwent the PEG procedure for the first time during this study. Eight patients who underwent PEG placement by 2 endoscopists were not enrolled in the study. A total of 54 patients were investigated. The patients' mean age was 69.9 years. The most common indication for PEG was cerebral infarct, which occurred in approximately two-thirds of the patients. The mean albumin level was 3.04 ± 0.7 g/dL, and 76.2% of the patients' albumin levels were below the normal values. The mean CRP level was high in 90.6% of patients prior to the procedure. Approximately two-thirds of the patients received antibiotics for either prophylaxis or treatment for infections prior to the PEG procedure. Mortality was not related to the procedure in any of the patients. Buried bumper syndrome was the only major complication, and it occurred in the third year. In such case, the PEG was removed and a new PEG tube was placed via surgery. Eight patients (15.1%) experienced minor complications, 6 (11.1%) of which were wound infections. All wound infections except one recovered with antibiotic treatment. Two patients

  12. Decreasing Use of Percutaneous Endoscopic Gastrostomy Tube Feeding in Japan.

    PubMed

    Komiya, Kosaku; Usagawa, Yuko; Kadota, Jun-Ichi; Ikegami, Naoki

    2018-05-25

    To identify trends in percutaneous endoscopic gastrostomy (PEG) tube placement and intravenous hyperalimentation (IVH) in nonhospital settings (as a potential alternative to tube feeding for nutrition) and to summarize published reports concerning the decision-making process for PEG placement. National survey and systematic review. Japan. All Japanese people. Data on numbers of individuals with a PEG tube and IVH were obtained from the website of the Japanese Ministry of Health, Labour, and Welfare and published reports concerning the decision-making process for PEG placement in Japan were summarized. The number of PEG tube placements peaked in 2007 and has been decreasing since Japan experienced the Great East Japan Earthquake in 2011. A further decline was seen in 2015 after the Japanese Ministry of Health, Labour and Welfare revised the fee schedule in 2014. More than half of individuals who had tubes were aged 80 and older during the years observed. In contrast, the number of individuals receiving IVH was lowest in the same year as PEG tube placement peaked and has been increasing ever since. Four studies reported that the decision-making process included consideration of not only the underlying disease, but also the individual's age and social barriers and the physician's personal philosophy. The number of PEG tube placements has been decreasing since its peak in 2007, and the number of individuals receiving IVH has been increasing. Many factors influence the decision-making process for PEG tube placement. Physicians in Japan may be realizing that there is little evidence to support the use of tube feeding in frail elderly adults. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.

  13. Gastroenteric tube feeding: Techniques, problems and solutions

    PubMed Central

    Blumenstein, Irina; Shastri, Yogesh M; Stein, Jürgen

    2014-01-01

    Gastroenteric tube feeding plays a major role in the management of patients with poor voluntary intake, chronic neurological or mechanical dysphagia or gut dysfunction, and patients who are critically ill. However, despite the benefits and widespread use of enteral tube feeding, some patients experience complications. This review aims to discuss and compare current knowledge regarding the clinical application of enteral tube feeding, together with associated complications and special aspects. We conducted an extensive literature search on PubMed, Embase and Medline using index terms relating to enteral access, enteral feeding/nutrition, tube feeding, percutaneous endoscopic gastrostomy/jejunostomy, endoscopic nasoenteric tube, nasogastric tube, and refeeding syndrome. The literature showed common routes of enteral access to include nasoenteral tube, gastrostomy and jejunostomy, while complications fall into four major categories: mechanical, e.g., tube blockage or removal; gastrointestinal, e.g., diarrhea; infectious e.g., aspiration pneumonia, tube site infection; and metabolic, e.g., refeeding syndrome, hyperglycemia. Although the type and frequency of complications arising from tube feeding vary considerably according to the chosen access route, gastrointestinal complications are without doubt the most common. Complications associated with enteral tube feeding can be reduced by careful observance of guidelines, including those related to food composition, administration rate, portion size, food temperature and patient supervision. PMID:25024606

  14. [Prehospital airway management of laryngeal tubes. Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?].

    PubMed

    Dengler, V; Wilde, P; Byhahn, C; Mack, M G; Schalk, R

    2011-02-01

    Laryngeal tubes (LT) are increasingly being used for emergency airway management. This article reports on two patients in whom out-of-hospital intubation with a single-lumen LT was associated with massive pulmonary aspiration in one patient and gastric overinflation in the other. In both cases peak inspiratory pressures exceeded the LT leak pressure of approximately 35 mbar. This resulted in gastric inflation and decreased pulmonary compliance and increased inspiratory pressure further, thereby creating a vicious circle. It is therefore recommended that laryngeal tube suction (LTS) should be used in all cases of emergency airway management and a gastric drain tube be inserted through the dedicated second lumen. Apart from gastric overinflation, incorrect LT/LTS placement must be detected and immediately corrected, e.g. in cases of difficult or impossible gastric tube placement, permanent drainage of air from the gastric tube, decreasing minute ventilation or an ascending capnography curve.

  15. A simple method for accurate endotracheal placement of an intubation tube in Guinea pigs to assess lung injury following chemical exposure.

    PubMed

    Nambiar, M P; Gordon, R K; Moran, T S; Richards, S M; Sciuto, A M

    2007-01-01

    ABSTRACT Guinea pigs are considered as the animal model of choice for toxicology and medical countermeasure studies against chemical warfare agents (CWAs) and toxic organophosphate pesticides because of the low levels of carboxylesterase compared to rats and mice. However, it is difficult to intubate guinea pigs without damaging the larynx to perform CWA inhalation experiments. We describe an easy technique of intubation of guinea pigs for accurate endotracheal placement of the intubation tube. The technique involves a speculum made by cutting the medium-size ear speculum in the midline leaving behind the intact circular connector to the otoscope. Guinea pigs were anesthetized with Telazol/meditomidine, the tongue was pulled using blunt forceps, and an otoscope attached with the specially prepared speculum was inserted gently. Insertion of the speculum raises the epiglottis and restrains the movements of vocal cord, which allows smooth insertion of the metal stylet-reinforced intubation tube. Accurate endotracheal placement of the intubation tube was achieved by measuring the length from the tracheal bifurcation to vocal cord and vocal cord to the upper front teeth. The average length of the trachea in guinea pigs (275 +/- 25 g) was 5.5 +/- 0.2 cm and the distance from the vocal cord to the front teeth was typically 3 cm. Coinciding an intubation tube marked at 6 cm with the upper front teeth accurately places the intubation tube 2.5 cm above the tracheal bifurcation. This simple method of intubation does not disturb the natural flora of the mouth and causes minimum laryngeal damage. It is rapid and reliable, and will be very valuable in inhalation exposure to chemical/biological warfare agents or toxic chemicals to assess respiratory toxicity and develop medical countermeasures.

  16. Effect of physician education and patient counseling on inpatient nonsurgical percutaneous feeding tube placement rate, indications, and outcome.

    PubMed

    Swaminath, Arun; Longstreth, George F; Runnman, Eva M; Yang, Su-Jau

    2010-02-01

    The decision to place a percutaneous feeding tube (PFT) in patients who are at the end of life is multidimensional and often complicated. We assessed the effect of physician education and counseling for patients and their surrogates on inpatient nonsurgical (endoscopic and radiologic) PFT placement rates, indications, complications, and mortality. In a pre-paid group practice, a geriatrician initiated a program of physician education and patient/surrogate counseling on the ethical and nutritional aspects of long-term enteral feeding. We compared rates of nonsurgical PFT placement (excluding those for cancer therapy or gastric decompression), indications, complications, and short- and long-term mortality in adult inpatients before (2004) and after (2005) the program. In 2004 and 2005, 115 and 60 inpatients underwent PFT placement, respectively. The annual number of hospital admissions was similar, but the rate of PFT placement declined (0.80% vs. 0.44%, P < 0.0001). The indications were cerebrovascular accident (42 [37%] versus 22 [37%]), dementia (15 [13%] versus 3 [5%]), other neurological disease (28 [24%] versus 16 [26%]), and miscellaneous disease (30 [26%] versus 19 [32%]); P > 0.05. Severe infectious complications occurred in 4 (3%) versus 0 (0%) patients, P > 0.05. Mortality (2004 versus 2005) at 30 days (23 [20%] versus 11 [18%]), 1 year (62 [54%] versus 29 [48%]) and 2 years (72 [63%] versus 31 [52%]) was similar, P > 0.05. A pilot program of educating referring physicians and counseling patients and their surrogates reduced the rate of inpatient PFT placement by nearly 50%. Indications, severe complications and short- and long-term mortality remained unchanged.

  17. Transanal drainage tube placement to prevent anastomotic leakage following colorectal cancer surgery with double stapling reconstruction.

    PubMed

    Matsuda, Mutsuhito; Tsuruta, Masashi; Hasegawa, Hirotoshi; Okabayashi, Koji; Kondo, Takayuki; Shimada, Takehiro; Yahagi, Masashi; Yoshikawa, Yusuke; Kitagawa, Yuko

    2016-05-01

    Anastomotic leakage (AL) is a critical complication of colorectal cancer surgery. The transanal drainage tube (TDT) is designed to prevent AL caused by decompression and stasis at the anastomosis. We conducted this study to investigate the feasibility of using the TDT to prevent AL following double-stapling technique reconstruction (DST). The subjects of this study were 179 patients who underwent curative resection and DST reconstruction for sigmoid colon and rectal cancer in our institution between 2008 and 2013. We analyzed the effectiveness of the TDT for preventing AL. A TDT was placed in 78 patients (43.6 %, TDT group) and not placed in the remaining 101 patients (56.4 %, NTDT group). AL developed in 2 (2.6 %) patients from the TDT group and in 14 (13.9 %) patients from the NTDT group (p = 0.009). Univariate analysis revealed that AL was significantly correlated with tumor distance from the anal verge (AV), the number of staples, and TDT placement. Multivariate analysis revealed a significantly positive correlation between AL and AV [OR 0.877 (0.783-0.982) p = 0.023] and a significantly negative correlation between AL and TDT placement [OR 0.07 (0.013-0.374) p = 0.002]. Anastomotic decompression with TDT placement may prevent AL after colorectal cancer surgery with DST reconstruction.

  18. ATLS: Catheter and tube placement

    NASA Technical Reports Server (NTRS)

    Gosbee, John; Krupa, Debra T.; Pepper, L.; Orsak, Debra

    1991-01-01

    The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.

  19. Use of an esophagostomy tube as a method of nutritional management in raptors: a case series.

    PubMed

    Huynh, Minh; Sabater, Mikel; Brandão, João; Forbes, Neil A

    2014-03-01

    We determined if esophagostomy tube placement is feasible for nutritional support in raptors. The clinical data were reviewed from 18 raptors admitted between 2006 and 2012, and in which esophagostomy tubes were placed. Indications for tube placement, complications associated with its placement and management, duration of treatment, and changes in patient body weight were evaluated. The most common indication was nutritional and medical support in stressed hospitalized animals, and intensive care cases. Complications were regurgitation, unexpected removal, and misplacement of the tube. The esophagostomy tube was well tolerated in all but 2 cases. A tube was replaced once in 2 patients. Five birds died during the treatment course. Mortality was not associated with the placement of the tube. Average duration of tube placement was 6.1 +/- 3.7 days. Most birds did not gain any weight with use of the feeding tubes. Esophagostomy tubes are well tolerated in raptors, but further studies are needed to demonstrate their efficiency.

  20. Evaluating the Role of Prophylactic Gastrostomy Tube Placement Prior to Definitive Chemoradiotherapy for Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Allen M., E-mail: allen.chen@ucdmc.ucdavis.ed; Li Baoqing; Lau, Derick H.

    2010-11-15

    Purpose: To determine the effect of prophylactic gastrostomy tube (GT) placement on acute and long-term outcome for patients treated with definitive chemoradiotherapy for locally advanced head and neck cancer. Methods and Materials: One hundred twenty consecutive patients were treated with chemoradiotherapy for Stage III/IV head and neck cancer to a median dose of 70 Gy (range, 64-74 Gy). The most common primary site was the oropharynx (66 patients). Sixty-seven patients (56%) were treated using intensity-modulated radiotherapy (IMRT). Seventy patients (58%) received prophylactic GT placement at the discretion of the physician before initiation of chemoradiotherapy. Results: Prophylactic GT placement significantly reducedmore » weight loss during radiation therapy from 43 pounds (range, 0 to 76 pounds) to 19 pounds (range, 0 to 51 pounds), which corresponded to a net change of -14% (range, 0% to -30%) and -8% (range, +1% to -22%) from baseline, respectively (p < 0.001). However, the proportion of patients who were GT-dependent at 6- and 12-months after treatment was 41% and 21%, respectively, compared with 8% and 0%, respectively, for those with and without prophylactic GT (p < 0.001). Additionally, prophylactic GT was associated with a significantly higher incidence of late esophageal stricture compared with those who did not have prophylactic GT (30% vs. 6%, p < 0.001). Conclusions: Although prophylactic GT placement was effective at preventing acute weight loss and the need for intravenous hydration, it was also associated with significantly higher rates of late esophageal toxicity. The benefits of this strategy must be balanced with the risks.« less

  1. Nasogastric feeding tube

    MedlinePlus

    ... chap 16. Ziegler TR. Malnutrition, nutritional assessment, and nutritional support in adult hospitalized patients. In: Goldman L, Schafer ... A.M. Editorial team. Related MedlinePlus Health Topics Nutritional Support Browse the Encyclopedia A.D.A.M., Inc. ...

  2. Same-Day Evaluation and Surgery for Otitis Media and Tympanostomy Tube Placement: A Feasibility Study.

    PubMed

    Billings, Kathleen R; Hajduk, John; Rose, Allison; De Oliveira, Gildasio S; Suresh, Suresh S; Thompson, Dana M

    2016-10-01

    To determine the feasibility of providing streamlined same-day evaluation and surgical management of children with recurrent otitis media or chronic serous otitis media who meet criteria for tympanostomy tube (TT) placement. Retrospective matched case series. Tertiary care children's hospital. A comparison group (age, sex, insurance product) was utilized to determine if the same-day process decreased facility time and surgical time for the care episode. A parent satisfaction survey was administered. Thirty children, with a median age of 16 months (range, 12-22 months), participated in the same-day surgery process for TT. Twenty-one patients (70.0%) were male, and these patients were matched to a comparison group (similar age, sex, and insurance product) having non-same-day (routine) TT placement. The same-day patients spent significantly less time in clinic for the preoperative physician visit (average, 15 minutes) when compared with the non-same-day patients (average, 51.5 minutes; P < .001). The operative experience for the same-day patients was similar to the non-same-day patients (average, 145 vs 137 minutes, respectively; P = .35), but the overall experience was significantly shorter for the same-day patients (average, 151 vs 196 minutes for comparisons; P < .001). All parents surveyed in the same-day group were satisfied with the efficiency of the experience. The same-day surgery process for management of children who meet the criteria for TT placement is a model of improved efficiency of care for children who suffer from otitis media. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  3. Tubeless percutaneous nephrolithotomy with non-absorbable hemostatic sealant (Quikclot®) versus nephrostomy tube placement: a propensity score-matched analysis.

    PubMed

    Koo, Kyo Chul; Park, Sang Un; Jang, Ho Sung; Hong, Chang-Hee

    2015-11-01

    The purpose of this study was to determine the efficacy and safety of tubeless percutaneous nephrolithotomy (PNL) using a non-absorbable hemostatic sealant (Quikclot(®)) as an adjunct compared to nephrostomy tube placement in patients exhibiting significant parenchymal bleeding following PNL. We identified 113 PNL cases performed between May 2011 and October 2014. For patients with insignificant parenchymal bleeding following stone removal, defined as a clear visualization of the surgical field at full irrigation of the nephroscope, tubeless PNL was performed. For patients with significant parenchymal bleeding, we introduced the tubeless Quikclot(®) technique as of September 2013 and have performed it ever since. Formerly, nephrostomy placement PNL was performed. In this study, 40 Quikclot(®) applied PNL cases were matched with an equal number of nephrostomy placement cases by propensity scoring based on body mass index, stone size, and Guy's stone score. The mean postoperative drop in hematocrit was comparative between the Quikclot(®) group and the nephrostomy group on both postoperative days 1 (p = 0.459) and 2 (p = 0.325). Quikclot(®) application was associated with lower VAS scores throughout the postoperative period, lower cumulative analgesic requirement (p = 0.025), and with shorter hospitalization (p = 0.002). Complication rates were comparable with no need for blood transfusions in any patients. Tubeless Quikclot(®) PNL was safe and provided effective hemostasis of significant parenchymal bleeding. By avoiding nephrostomy placement, we were able to reduce postoperative pain, analgesic requirements, and hospitalization. Application of Quikclot(®) may be considered prior to nephrostomy placement in patients with significant parenchymal bleeding.

  4. Bilateral Pneumothoraces in a Trauma Patient After Dobhoff Tube Insertion.

    PubMed

    Abidali, Ali; Mangram, Alicia; Shirah, Gina R; Wilson, Whitney; Abidali, Ahmed; Moeser, Phillip; Dzandu, James K

    2018-03-05

    BACKGROUND Dobhoff tube insertion is a common procedure used in the clinical setting to deliver enteral nutrition. Although it is often viewed as an innocuous bedside procedure, there are risks for numerous complications such as tracheobronchial insertion, which could lead to deleterious consequences. We present to our knowledge the first reported case of bilateral pneumothoraces caused by the insertion of a Dobhoff tube. In addition, we also discuss common pitfalls for confirming the positioning of Dobhoff tubes, as well as risk factors that can predispose a patient to improper tube placement. CASE REPORT We present the case of a 74-year-old male patient with multiple orthopedic injuries following an auto-pedestrian collision. Five attempts were made to place a Dobhoff tube to maintain enteral nutrition. Follow-up abdominal x-ray revealed displacement of the Dobhoff tube in the left pleural space. After removal of the tube, a follow-up chest x-ray revealed iatrogenic bilateral pneumothoraces. Acute hypoxemic respiratory failure ensued; therefore, bilateral chest tubes were placed. Over the next three weeks, the patient's respiratory status improved and both chest tubes were removed. The patient was eventually discharged to a skilled nursing facility. CONCLUSIONS Improper placement of Dobhoff tubes can lead to rare complications such as bilateral pneumothoraces. This unique case report of bilateral pneumothoraces after Dobhoff tube placement emphasizes the necessity of using proper diagnostic techniques for verifying proper tube placement, as well as understanding the risk factors that predispose a patient to a malpositioned tube.

  5. Home enteral nutrition: organisation of services.

    PubMed

    Green, Sue; Dinenage, Sarah; Gower, Morwenna; Van Wyk, Johanna

    2013-05-01

    This article discusses how services for people receiving enteral nutrition via a nasogastric or gastrostomy tube at home are organised. The home enteral nutrition team's role is also explored. The National Institute for Health and Care Excellence outlines the need for nutritional support in adults to be high quality and cost effective. It is important therefore that local services are able to provide people receiving enteral nutrition with safe and effective care that they consider satisfactory. The discussion is pertinent to nurses caring for older people because gastrostomy tube placement is increasingly common in people aged over 60. A gastrostomy tube is the usual route by which enteral nutrition is given in the community.

  6. An evaluation of the retromolar space for oral tracheal tube placement for maxillofacial surgery in children.

    PubMed

    Arora, Suman; Rattan, Vidya; Bhardwaj, Neerja

    2006-11-01

    The eruption of the first and second permanent molar teeth may influence the size of the retromolar space. In this study we evaluated the adequacy of the retromolar space for retromolar intubation and any effect of eruption of the first and second permanent molar teeth on this space in children. Children 3-15 yr of age, undergoing surgery other than facial surgery were included for evaluation of the retromolar space. After standard oral tracheal intubation, the endotracheal tube was shifted to the retromolar space and the mandible was slowly closed to achieve centric occlusion. At the same time, any increase in airway resistance or decrease in oxygen saturation was noted. In the second part of the study, the feasibility of retromolar intubation in pediatric patients undergoing maxillofacial surgery with intraoperative maxillomandibular fixation was assessed. There was enough space for endotracheal tube placement in the retromolar region. The eruption of the first and second permanent molar teeth did not affect intubation. It was possible to achieve centric occlusion in 79 of 80 children with the endotracheal tube positioned in the retromolar space. Retromolar intubation was successfully accomplished in six pediatric patients undergoing maxillomandibular fixation and maxillofacial surgery. The retromolar space can be safely used for intubation in children when intraoperative maxillomandibular fixation, and simultaneous access to the nose and oral cavity are needed.

  7. Bilateral Pneumothoraces in a Trauma Patient After Dobhoff Tube Insertion

    PubMed Central

    Abidali, Ali; Mangram, Alicia; Shirah, Gina R.; Wilson, Whitney; Abidali, Ahmed; Moeser, Phillip; Dzandu, James K.

    2018-01-01

    Patient: Male, 74 Final Diagnosis: Pneumothorax Symptoms: Hypoxemia • shortness of breath Medication: — Clinical Procedure: — Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: Dobhoff tube insertion is a common procedure used in the clinical setting to deliver enteral nutrition. Although it is often viewed as an innocuous bedside procedure, there are risks for numerous complications such as tracheobronchial insertion, which could lead to deleterious consequences. We present to our knowledge the first reported case of bilateral pneumothoraces caused by the insertion of a Dobhoff tube. In addition, we also discuss common pitfalls for confirming the positioning of Dobhoff tubes, as well as risk factors that can predispose a patient to improper tube placement. Case Report: We present the case of a 74-year-old male patient with multiple orthopedic injuries following an auto-pedestrian collision. Five attempts were made to place a Dobhoff tube to maintain enteral nutrition. Follow-up abdominal x-ray revealed displacement of the Dobhoff tube in the left pleural space. After removal of the tube, a follow-up chest x-ray revealed iatrogenic bilateral pneumothoraces. Acute hypoxemic respiratory failure ensued; therefore, bilateral chest tubes were placed. Over the next three weeks, the patient’s respiratory status improved and both chest tubes were removed. The patient was eventually discharged to a skilled nursing facility. Conclusions: Improper placement of Dobhoff tubes can lead to rare complications such as bilateral pneumothoraces. This unique case report of bilateral pneumothoraces after Dobhoff tube placement emphasizes the necessity of using proper diagnostic techniques for verifying proper tube placement, as well as understanding the risk factors that predispose a patient to a malpositioned tube. PMID:29503437

  8. A method for early diagnosis and treatment of intrathoracic esophageal anastomotic leakage: prophylactic placement of a drainage tube adjacent to the anastomosis.

    PubMed

    Tang, Hua; Xue, Lei; Hong, Jiang; Tao, Xiandong; Xu, Zhifei; Wu, Bin

    2012-04-01

    Anastomotic leakage is a severe complication after esophagectomy, which results in high mortality and morbidity. In this study, we will preset a drainage tube adjacent to the anastomosis and evaluate its effect in the diagnosis and treatment of anastomotic leakage. We undertook a retrospective review of 414 patients who underwent partial esophageal resection or cardia resection with intrathoracic esophagogastric anastomosis. The patients were divided into two groups (Tube group and no-tube group) according to whether a drainage tube was placed adjacent to the anastomotic stoma during the surgical procedure. The leakage rate, time to diagnosis, time to flush, time to recovery, and patient outcome were analyzed. The leakage rate in the tube group was 5.35% (6/112) while it was 3.64% (11/302) in the no-tube group. The total mortality among patients with anastomotic leakage was 29.41%. In the tube group, all the patients were definitively diagnosed the same day on which suspicion of leakage occurs while the patients in the no-tube group required further examination to diagnose. In the no-tube group, the patients required placement of a drainage tube with the help of computed tomography or ultrasonic examination while there was no need for further procedures in the tube group. The days to flush and recovery in the tube group were 23.4 ± 5.94 and 32.2 ± 10.84, respectively, while, in the no-tube group, it was 80.71 ± 48.41 and 98.14 ± 56.24 (P < 0.05). In conclusion, prophylactic implantation of a drainage tube adjacent to the esophageal anastomosis is a good method for rapid diagnosis and treatment of leakage.

  9. Predictive Factors for Prophylactic Percutaneous Endoscopic Gastrostomy (PEG) Tube Placement and Use in Head and Neck Patients Following Intensity-Modulated Radiation Therapy (IMRT) Treatment: Concordance, Discrepancies, and the Role of Gabapentin.

    PubMed

    Yang, Wuyang; McNutt, Todd R; Dudley, Sara A; Kumar, Rachit; Starmer, Heather M; Gourin, Christine G; Moore, Joseph A; Evans, Kimberly; Allen, Mysha; Agrawal, Nishant; Richmon, Jeremy D; Chung, Christine H; Quon, Harry

    2016-04-01

    The prophylactic placement of a percutaneous endoscopic gastrostomy (PEG) tube in the head and neck cancer (HNC) patient is controversial. We sought to identify factors associated with prophylactic PEG placement and actual PEG use. Since 2010, data regarding PEG placement and use were prospectively recorded in a departmental database from January 2010 to December 2012. HNC patients treated with intensity-modulated radiation therapy (IMRT) were retrospectively evaluated from 2010 to 2012. Variables potentially associated with patient post-radiation dysphagia from previous literature, and our experience was evaluated. We performed multivariate logistic regression on these variables with PEG placement and PEG use, respectively, to compare the difference of association between the two arms. We identified 192 HNC patients treated with IMRT. Prophylactic PEG placement occurred in 121 (63.0 %) patients, with PEG use in 97 (80.2 %) patients. PEG placement was associated with male gender (p < .01), N stage ≥ N2 (p < .05), pretreatment swallowing difficulties (p < .01), concurrent chemotherapy (p < .01), pretreatment KPS ≥80 (p = .01), and previous surgery (p = .02). Concurrent chemotherapy (p = .03) was positively associated with the use of PEG feeding by the patient, whereas pretreatment KPS ≥80 (p = .03) and prophylactic gabapentin use (p < .01) were negatively associated with PEG use. The analysis suggests there were discrepancies between prophylactic PEG tube placement and actual use. Favorable pretreatment KPS, no pretreatment dysphagia, no concurrent chemotherapy, and the use of gabapentin were significantly associated with reduced PEG use. This analysis may help refine the indications for prophylactic PEG placement.

  10. Angioplasty and stent placement - peripheral arteries

    MedlinePlus

    ... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...

  11. Parameter predicting the recurrence of adhesive small bowel obstruction in patients managed with a long tube.

    PubMed

    Sakakibara, Takumi; Harada, Akio; Ishikawa, Tadao; Komatsu, Yoshinao; Yaguchi, Toyohisa; Kodera, Yasuhiro; Nakao, Akimasa

    2007-01-01

    Some of our patients showed a recurrence of adhesive small bowel obstruction (ASBO) with nonoperative management. The aim of this study was to evaluate the parameters predicting the recurrence of ASBO in patients managed with a long tube. Of 234 patients with ASBO admitted from April 1998 to September 2002, a total of 91 who recovered with nonoperative management after long tube placement were enrolled in this retrospective clinical study. We divided them into two groups for follow-up: the recurrence group and the no-recurrence group. We compared baseline characteristics, the number of previous ASBO admissions, the number of abdominal operations, the interval from the onset of symptoms to long-tube insertion, the duration of long-tube placement, the type of the contrasted intestine through the long tube, the location of the long-tube tip, and the drainage volume through the long tube between the two groups. We then examined the cumulative recurrence rate. A significant difference was found in the number of previous ASBO admissions, the duration of long-tube placement (77 hours vs. 43 hours), the contrasted intestine through the long tube, and the location of the long-tube tip. By multivariate analysis, the duration of long-tube placement was an independent parameter predicting the recurrence of ASBO. These results suggest that the duration of long-tube placement might serve as a parameter for predicting recurrence of ASBO in patients managed with a long tube.

  12. Effect of timing and method of enteral tube feeding for dysphagic stroke patients (FOOD): a multicentre randomised controlled trial.

    PubMed

    Dennis, M S; Lewis, S C; Warlow, C

    Undernutrition is common in patients admitted with stroke. We aimed to establish whether the timing and route of enteral tube feeding after stroke affected patients' outcomes at 6 months. The FOOD trials consist of three pragmatic multicentre randomised controlled trials, two of which included dysphagic stroke patients. In one trial, patients enrolled within 7 days of admission were randomly allocated to early enteral tube feeding or no tube feeding for more than 7 days (early versus avoid). In the other, patients were allocated percutaneous endoscopic gastrostomy (PEG) or nasogastric feeding. The primary outcome was death or poor outcome at 6 months. Analysis was by intention to treat. Between Nov 1, 1996, and July 31, 2003, 859 patients were enrolled by 83 hospitals in 15 countries into the early versus avoid trial. Early tube feeding was associated with an absolute reduction in risk of death of 5.8% (95% CI -0.8 to 12.5, p=0.09) and a reduction in death or poor outcome of 1.2% (-4.2 to 6.6, p=0.7). In the PEG versus nasogastric tube trial, 321 patients were enrolled by 47 hospitals in 11 countries. PEG feeding was associated with an absolute increase in risk of death of 1.0% (-10.0 to 11.9, p=0.9) and an increased risk of death or poor outcome of 7.8% (0.0 to 15.5, p=0.05). Early tube feeding might reduce case fatality, but at the expense of increasing the proportion surviving with poor outcome. Our data do not support a policy of early initiation of PEG feeding in dysphagic stroke patients.

  13. Family Experiences With Feeding Tubes in Neurologic Impairment: A Systematic Review.

    PubMed

    Nelson, Katherine E; Lacombe-Duncan, Ashley; Cohen, Eyal; Nicholas, David B; Rosella, Laura C; Guttmann, Astrid; Mahant, Sanjay

    2015-07-01

    Gastrostomy tubes (G-tubes) are frequently used to provide enteral nutrition for children who have neurologic impairment. Understanding the impact of G-tubes from the family's perspective will inform decision-making and improve support from health care providers. This study explored the experiences of families after G-tube placement in children with neurologic impairment. We conducted a systematic review of English-language qualitative primary research studies describing family experiences after G-tube placement. Six electronic databases were searched from inception to June 2014. Two authors independently screened and identified relevant studies, evaluated quality of reporting by using the Consolidated Criteria for Reporting Qualitative Research tool, and extracted data. Overarching concepts were developed by using thematic analysis. From 2674 screened abstracts, 84 texts were reviewed, and 13 studies met the inclusion criteria. G-tubes affect the lives of children, parents, and the family unit in many ways, both positive and negative. Improvements and challenges were described for children's health and happiness, for parental caregiving and stress, and for logistics and bonding within the family. G-tube feeding also changed relationships within the family, between the family and the medical system, and between the family and the outside world. Furthermore, experiences varied, with different families framing similar concepts as positive and negative. G-tube placement has diverse effects on daily life for children with neurologic impairment and their families. Clinicians may use the themes identified in this study to guide conversations with families about their values, experiences, and expectations before and after G-tube placement. Copyright © 2015 by the American Academy of Pediatrics.

  14. Relative Bioavailability of Apixaban Solution or Crushed Tablet Formulations Administered by Mouth or Nasogastric Tube in Healthy Subjects.

    PubMed

    Song, Yan; Wang, Xiaoli; Perlstein, Itay; Wang, Jessie; Badawy, Sherif; Frost, Charles; LaCreta, Frank

    2015-08-01

    Crushed tablet and solution formulations of apixaban administered orally or via a nasogastric tube (NGT) may be useful in patients unable to swallow solid dose formulations. It is important to understand whether new formulations and/or methods of administration impact apixaban bioavailability and pharmacokinetic properties. These studies evaluated the relative bioavailability (Frel) of apixaban solution administered orally; oral solution administered via NGT flushed with either 5% dextrose in water (D5W) or with infant formula; oral solution via NGT with a nutritional supplement; and crushed tablet suspended in D5W and administered via NGT. Three open-label, randomized, crossover studies were conducted in healthy adults (study 1: apixaban 10-mg tablet [reference] versus oral solution, both administered PO; study 2: apixaban 5-mg oral solution PO [reference] versus oral solution via NGT flushed with either D5W or infant formula; study 3: apixaban 5-mg oral solution PO [reference] versus apixaban 5-mg oral solution via NGT with a nutritional supplement and versus crushed tablet suspended in D5W and administered via NGT). Point estimates and 90% CIs of the geometric mean ratios (GMRs; test/reference) were generated for Cmax and AUC. Adverse events were recorded throughout each study. Frel of the oral solution was 105% versus tablet, and Frel for oral solution via NGT with D5W flush, infant formula flush, nutritional supplement, and crushed tablet via NGT versus oral solution administration were 96.7%, 92.2%, 81.3%, and 95.1%, respectively. The 90% CIs of the GMRs of all AUCs met the bioequivalence criterion except that of the nutritional supplement (0.766-0.863). The corresponding GMRs for Cmax were 0.977, 0.953, 0.805, 0.682, and 0.884. For the solution via NGT flushed with D5W and for the crushed tablet, the 90% CIs of the Cmax GMRs met the bioequivalence criterion. Apixaban was well tolerated in all 3 studies; most adverse events were mild. Comparable Frel was

  15. Angioplasty and stent placement - carotid artery - discharge

    MedlinePlus

    ... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...

  16. Nutritional status and feeding-tube placement in patients with locally advanced hypopharyngeal cancer included in an induction chemotherapy-based larynx preservation program.

    PubMed

    Bozec, Alexandre; Benezery, Karen; Chamorey, Emmanuel; Ettaiche, Marc; Vandersteen, Clair; Dassonville, Olivier; Poissonnet, Gilles; Riss, Jean-Christophe; Hannoun-Lévi, Jean-Michel; Chand, Marie-Eve; Leysalle, Axel; Saada, Esma; Sudaka, Anne; Haudebourg, Juliette; Hebert, Christophe; Falewee, Marie-Noelle; Demard, François; Santini, José; Peyrade, Frédéric

    2016-09-01

    The objective of the study is to evaluate the nutritional status and determine its impact on clinical outcomes in patients with locally advanced hypopharyngeal cancer included in an induction chemotherapy (ICT)-based larynx preservation program without prophylactic feeding-tube placement. All patients with locally advanced (T3/4, N0-3, M0) hypopharyngeal squamous cell carcinoma, technically suitable for total pharyngolaryngectomy, treated by docetaxel, cisplatin and 5-fluorouracil (TPF)-ICT for larynx preservation at our institution between 2004 and 2013, were included in this retrospective study. Patients' nutritional status was closely monitored. Enteral nutrition was used if and when a patient was unable to sustain per-oral nutrition and hydration. The impact of nutritional status on clinical outcomes was investigated in univariate and multivariate analysis. A total of 53 patients (42 men and 11 women, mean age = 58.6 ± 8.2 years) were included in this study. Six (11.3 %) patients had lost more than 10 % of their usual body weight before therapy. Compared with patients' usual weight, the mean maximum patient weight loss during therapeutic management was 8.7 ± 4.5 kg. Enteral nutrition was required in 17 patients (32 %). We found no influence of the tested nutritional status-related factors on response to ICT, toxicity of ICT, overall, cause-specific and recurrence-free survival, and on post-therapeutic swallowing outcome. Maximum weight loss was significantly associated with a higher risk of enteral tube feeding during therapy (p = 0.03) and of complications (grade ≥3, p = 0.006) during RT. Without prophylactic feeding-tube placement, approximately one-third of the patients required enteral nutrition. There was no significant impact of nutritional status on oncologic or functional outcomes.

  17. Health Instruction Packages: Specific Nursing Skills.

    ERIC Educational Resources Information Center

    Bates, Clarice; And Others

    Text, illustrations, and exercises are utilized in a set of five learning modules designed to instruct nursing students in a variety of clinical skills. The first module, "Down the Tube: Insertion of a Nasogastric Tube" by Clarice Bates, describes materials and procedures used to insert a nasogastric tube through the nose and esophagus…

  18. Procedures for measuring and verifying gastric tube placement in newborns: an integrative review.

    PubMed

    Dias, Flávia de Souza Barbosa; Emidio, Suellen Cristina Dias; Lopes, Maria Helena Baena de Moraes; Shimo, Antonieta Keiko Kakuda; Beck, Ana Raquel Medeiros; Carmona, Elenice Valentim

    2017-07-10

    to investigate evidence in the literature on procedures for measuring gastric tube insertion in newborns and verifying its placement, using alternative procedures to radiological examination. an integrative review of the literature carried out in the Cochrane, LILACS, CINAHL, EMBASE, MEDLINE and Scopus databases using the descriptors "Intubation, gastrointestinal" and "newborns" in original articles. seventeen publications were included and categorized as "measuring method" or "technique for verifying placement". Regarding measuring methods, the measurements of two morphological distances and the application of two formulas, one based on weight and another based on height, were found. Regarding the techniques for assessing placement, the following were found: electromagnetic tracing, diaphragm electrical activity, CO2 detection, indigo carmine solution, epigastrium auscultation, gastric secretion aspiration, color inspection, and evaluation of pH, enzymes and bilirubin. the measuring method using nose to earlobe to a point midway between the xiphoid process and the umbilicus measurement presents the best evidence. Equations based on weight and height need to be experimentally tested. The return of secretion into the tube aspiration, color assessment and secretion pH are reliable indicators to identify gastric tube placement, and are the currently indicated techniques. investigar, na literatura, evidências sobre procedimentos de mensuração da sonda gástrica em recém-nascidos e de verificação do seu posicionamento, procedimentos alternativos ao exame radiológico. revisão integrativa da literatura nas bases Biblioteca Cochrane, LILACS, CINAHL, EMBASE, MEDLINE e Scopus, utilizando os descritores "intubação gastrointestinal" e "recém-nascido" em artigos originais. dezessete publicações foram incluídas e categorizadas em "método de mensuração" ou "técnica de verificação do posicionamento". Como métodos de mensuração, foram encontrados os de tomada

  19. [A project to reduce the incidence of intubation care errors among foreign health aides].

    PubMed

    Chen, Mei-Ju; Lu, Yu-Hua; Chen, Chiu-Chun; Li, Ai-Cheng

    2014-08-01

    Foreign health aides are the main providers of care for the elderly and the physically disabled in Taiwan. Correct care skills improve patient safety. In 2010, the incidence of mistakes among foreign health aides in our hospital unit was 58% for nasogastric tube care and 57% for tracheostomy tube care. A survey of foreign health aides and nurses in the unit identified the main causes of these mistakes as: communication difficulties, inaccurate instructions given to patients, and a lack of standard operating procedures given to the foreign health aides. This project was designed to reduce the rates of improper nasogastric tube care and improper tracheostomy tube care to 20%, respectively. This project implemented several appropriate measures. We produced patient instruction hand-outs in Bahasa Indonesia, established a dedicated file holder for Bahasa Indonesian tube care reference information, produced Bahasa Indonesian tube-care-related posters, produced a short film about tube care in Bahasa Indonesian, and established a standardized operating procedure for tube care in our unit. Between December 15th and 31st, 2011, we audited the performance of a total of 32 foreign health aides for proper execution of nasogastric tube care (21 aides) and of proper execution of tracheostomy tube care (11 aides). Patients with concurrent nasogastric and tracheostomy tubes were inspected separately for each care group. The incidence of improper care decreased from 58% to 18% nasogastric intubation and 57% to 18% for tracheostomy intubation. This project decreased significantly the incidence of improper tube care by the foreign health aides in our unit. Furthermore, the foreign health aides improved their tube nursing care skills. Therefore, this project improved the quality of patient care.

  20. Purposeful creation of a pneumothorax and chest tube placement to facilitate CT-guided coil localization of lung nodules before video-assisted thoracoscopic surgical wedge resection.

    PubMed

    Iqbal, Shams I; Molgaard, Christopher; Williamson, Christina; Flacke, Sebastian

    2014-07-01

    To evaluate the feasibility and efficacy of pneumothorax creation and chest tube insertion before computed tomography (CT)-guided coil localization of small peripheral lung nodules for video-assisted thoracoscopic surgical (VATS) wedge resection. From May 2011 to October 2013, 21 consecutive patients (seven men; mean age, 62 y; range, 42-76 y) scheduled for VATS wedge resection required CT-guided coil localization for small, likely nonpalpable peripheral lung lesions at a single institution. Outcomes were evaluated retrospectively for technical success and complications. There were 12 nodules and nine ground-glass opacities. Mean lesion distance from the pleural surface was 15 mm (range, 5-35 mm), and average size was 13 mm (range, 7-30 mm). A pneumothorax was successfully created in all patients with a Veress needle, and a chest tube was inserted. All target lesions were marked successfully, leaving one end of the coil within/beyond the lesion and the other end of the coil in the pleural space. The inserted chest tube was used to insufflate air to widen the pleural space during coil positioning and to aspirate any residual air before transfer of the patient to the operating room holding area. Intraparenchymal hemorrhages smaller than 7 cm in diameter developed in two patients during coil placement. All lesions were successfully resected with VATS. Histologic examinaiton revealed 13 primary adenocarcinomas, four metastases, and four benign lesions. Pneumothorax creation and chest tube placement before CT-guided coil localization of peripheral lung nodules for VATS wedge resection facilitates the deployment of the peripheral end of the coil in the pleural space and provides effective management of procedure-related pneumothorax until surgery. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  1. Simultaneous Umbilical Hernia Repair with Transumbilical Ventriculoperitoneal Shunt Placement.

    PubMed

    Montalbano, Michael J; Loukas, Marios; Oakes, W Jerry; Tubbs, R Shane

    2017-01-01

    Recently, placement of a ventriculoperitoneal shunt via a transumbilical approach has been reported. Herein, we report the repair of an umbilical hernia via the same incision and introduction of the distal end of a ventricultoperitoneal shunt into the peritoneal cavity in 3 patients. A case illustration is included. Both hernia repair and placement of the distal end of the ventriculoperitoneal shunt were uncomplicated in our small case series. To our knowledge, simultaneous repair of an umbilical hernia followed by transumbilical shunt placement has not been reported. As umbilical hernias are so common in infants, this finding, based on our experience, should not exclude placement of peritoneal tubing in the same setting. © 2017 S. Karger AG, Basel.

  2. [Head and neck cancer patients included at home enteral nutrition by tube].

    PubMed

    Cots Seignot, I; Cárdenas Lagranja, G; Puiggròs Llop, C; Chicharro Serrano, L; Pérez-Portabella Maristany, C; Planas Vilà, M

    2009-01-01

    To know characteristics and the patients' evolution with head and neck cancer who received radiotherapy treatment and they were included at a home enteral nutrition (HEN) by feeding tube programme. To analyse the weight evolution according to the start of HEN before or after radiotherapy. Observational study of tube feeding patients with head and neck cancer who were included in HEN programme in our hospital for two years. Variables analysed: gender, age, Body Mass Index (BMI), Karnofsky Index (KI), reason for nutritional support, type of feeding tube, formula used and prescribed caloric contribution, necessity to change access device and HEN days. 62 patients were studied (77.4% men; 22.6% women). Age 64 +/- 10.1 years (rang: 39-90). The dysphagia was the main cause to begin enteral nutrition by feeding tube in these patients. Naso-gastric tube was prevalence (67.7%). The most used formula was polymeric hypercaloric diet with a mean of caloric contribution of 1,629 +/- 267.09 kcal/day. Overall, there was a weight loss in all patients during the study period time. However, patients who began the HEN by feeding tube before the radiotherapy treatment, the BMI did not decrease. All patients who began feeding tube before oncological treatment didn't lose weight for the period of study.

  3. Stents in patients with esophageal cancer before chemoradiotherapy: high risk of complications and no impact on the nutritional status.

    PubMed

    Mão-de-Ferro, S; Serrano, M; Ferreira, S; Rosa, I; Lage, P; Alexandre, D P; Freire, J; Mirones, L; Casaca, R; Bettencourt, A; Pereira, A D

    2016-03-01

    Preoperative chemoradiotherapy is the standard of care for locally advanced esophageal cancer, causing persistent deterioration in the nutritional status. We performed a prospective study to evaluate the safety and efficacy of esophageal double-covered self-expandable metal stents in patients with esophageal cancer before chemoradiotherapy. The nutritional status and dysphagia were prospectively recorded. Eleven patients were included: eight were moderate and three were severely malnourished. After stent placement, dysphagia improved in all patients. With regard to complications, one patient developed an esophageal perforation that required urgent esophagectomy. Four patients presented stent migration. Three of these patients required enteral nutrition and none was submitted to surgery because of poor nutritional status. Of the other six patients, only four were operated upon. Stent placement presented a high complication rate and did not prevent weight loss or malnutrition. Other alternatives, including naso-gastric tube placement or endoscopic percutaneous gastrostomy or jejunostomy, should be considered.

  4. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    PubMed Central

    2010-01-01

    Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Conclusions Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery. PMID:20492665

  5. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report.

    PubMed

    Lai, Peng-Sheng; Lo, Chiao; Lin, Long-Wei; Lee, Po-Chu

    2010-05-21

    Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  6. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  7. Practical management of periprosthetic leakage in patients rehabilitated with a Provox® 2 voice prosthesis after total laryngectomy.

    PubMed

    Friedlander, Eviatar; Pinacho Martínez, Paloma; Poletti Serafini, Daniel; Martín-Oviedo, Carlos; Martínez Guirado, Tomás; Scola Yurrita, Bartolomé

    Periprosthetic leakage of liquids is a common complication in patients rehabilitated with voice prostheses. Our objective was to describe and review the results of procedures for treating periprosthetic leakage. This was a retrospective analysis of 41 patients rehabilitated with Provox® 2 voice prostheses between 1997 and 2015. We describe 3 techniques: periprosthetic silicon collar placement, injection of hyaluronic acid into the tracheoesophageal wall and the combination of the 2 techniques. We present a method to reduce the diameter of the tracheoesophageal fistula by removing the voice prosthesis and placing a nasogastric tube through the fistula. In the 3 groups treated with silicone collar (n=5, 13 procedures), hyaluronic acid injection (n=5, 9 procedures) and the combination of both techniques (n=3, 5 procedures), we observed an increase in prosthesis lifespan of an average of 56 days (range 7-118 days), 32 days (range 3-55 days) and 63 days (range 28-136 days), respectively. The tracheoesophageal fistula diameter reduction was performed in 100% (n=6) of patients. The use of silicone collars, injection of hyaluronic acid into the tracheoesophageal wall and the combination of both techniques for the treatment of periprosthesis leakage increase the lifespan of the prosthesis. Temporary prosthesis removal and placement of nasogastric tube has also been shown effective in our experience. These techniques are simple, inexpensive and reproducible, thereby reducing healthcare costs. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  8. Laparoscopic insertion of the Moss feeding tube.

    PubMed

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  9. Hollow mandrin facilitates external ventricular drainage placement.

    PubMed

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening

  10. Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrocelli, Francesco, E-mail: francesco.petrocelli@hsanmartino.it; Salsano, Giancarlo, E-mail: giancarlo.salsano@yahoo.it; Bovio, Giulio, E-mail: giulio.bovio@hsanmartino.it

    IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriformmore » sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.« less

  11. Effectiveness of Tympanostomy Tubes for Otitis Media: A Meta-analysis.

    PubMed

    Steele, Dale W; Adam, Gaelen P; Di, Mengyang; Halladay, Christopher H; Balk, Ethan M; Trikalinos, Thomas A

    2017-06-01

    Tympanostomy tube placement is the most common ambulatory surgery performed on children in the United States. The goal of this study was to synthesize evidence for the effectiveness of tympanostomy tubes in children with chronic otitis media with effusion and recurrent acute otitis media. Searches were conducted in Medline, the Cochrane Central Trials Registry and Cochrane Database of Systematic Reviews, Embase, and the Cumulative Index to Nursing and Allied Health Literature. Abstracts and full-text articles were independently screened by 2 investigators. A total of 147 articles were included. When feasible, random effects network meta-analyses were performed. Children with chronic otitis media with effusion treated with tympanostomy tubes compared with watchful waiting had a net decrease in mean hearing threshold of 9.1 dB (95% credible interval: -14.0 to -3.4) at 1 to 3 months and 0.0 (95% credible interval: -4.0 to 3.4) by 12 to 24 months. Children with recurrent acute otitis media may have fewer episodes after placement of tympanostomy tubes. Associated adverse events are poorly defined and reported. Sparse evidence is available, applicable only to otherwise healthy children. Tympanostomy tubes improve hearing at 1 to 3 months compared with watchful waiting, with no evidence of benefit by 12 to 24 months. Children with recurrent acute otitis media may have fewer episodes after tympanostomy tube placement, but the evidence base is severely limited. The benefits of tympanostomy tubes must be weighed against a variety of associated adverse events. Copyright © 2017 by the American Academy of Pediatrics.

  12. [INFLUENCE OF THE NUTRITIONAL COMPOSITION OF DIFFERENT FIBER-ENRICHED ENTERAL NUTRITION FORMULAS ON THE ADMINISTRATION TIME BY GRAVITY AND THE RISK OF TUBE FEEDING OBSTRUCTION].

    PubMed

    Bonada Sanjaume, Anna; Gils Contreras, Anna; Salas-Salvadó, Jordi

    2015-08-01

    the administration of enteral nutrition by gravity is a very useful method in clinical practice; nevertheless, it may not be very precise. Indeed, this method presents some important limitations, such as the difficulty in establishing a precise dripping rate and the possibility for the dripping rate decrease depending on the formula. assess the administration time and the risk of clogging of 5 fiber-enriched enteral nutrition formulas with different protein concentrations and caloric density, all administered by gravity through nasogastric (NG) tubes of different sizes. Assess the influence of the composition on the dripping rate, by gravity, of the tested formulas. 5 fiber-enriched EN formulas were compared by using nasogastric tubes of the calibers 8, 10 and 12 Fr. The fluidity of these gravity-administered NE formulas was estimated by timing the complete passage of each formula at full speed, thus allowing one to calculate the mean time of free fall (MTFF) and to register any possible obstruction. Subsequently, an in vitro simulation of a 1 500 ml administration was performed for each formula at a particular speed, so that the administration time was 5 hours. Slowing flow and stagnated flow were detected as indicators of the risk of obstruction. the two products that especially differed in MTFF were the ones with the highest energy concentration. The passage time in free fall of these two products through the 8 Fr tube exceeded four hours. For the rest of the products and NG tubes used, this time was less than 2 hours and 5 minutes. No slowing flow or tube obstruction was detected in free fall and at maximum speed. When the dripping was adjusted to be administered in 5 hours, three of the studied products (those with the least caloric concentration and viscosity) showed slowing flow and, in some cases, the dripping stopped completely. The most important factor associated to the MTFF was the lipid content, followed by viscosity, energy and protein content. The

  13. A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic Surgery.

    PubMed

    Heir, Jagtar Singh; Guo, Shu-Lin; Purugganan, Ronaldo; Jackson, Tim A; Sekhon, Anupamjeet Kaur; Mirza, Kazim; Lasala, Javier; Feng, Lei; Cata, Juan P

    2018-02-01

    To compare the incidence of fiberoptic bronchoscope (FOB) use (1) during verification of initial placement and (2) for reconfirmation of correct placement following repositioning, when either a double-lumen tube (DLT) or video double-lumen tube (VDLT) was used for lung isolation during thoracic surgery. A randomized controlled study. Single-center university teaching hospital. The study comprised 80 patients who were 18 years or older requiring lung isolation for surgery. After institutional review board approval, patients were randomized prior to surgery to either DLT or VDLT usage. Attending anesthesiologists placed the Mallinckrodt DLT or Vivasight (ET View Ltd, Misgav, Israel) VDLT with conventional laryngoscopy or video laryngoscopy then verified correct tube position through the view provided with either VDLT external monitor or FOB. Data collected included: sex, body mass index, successful intubation and endobronchial placement, intubation time, confirmation time of tube position, FOB use, quality of view, dislodgement of tube, and ability to forewarn dislodgement of endobronchial cuff and complications. FOB use for verification of final position of the tube (VDLT 13.2% [5/38] v DLT 100% [42/42], p < 0.0001), need for FOB to correct the dislodgement (VDLT 7.7% [1/13] v DLT 100% [14/14], p < 0.0001), dislodgement during positioning (VDLT 61.5% [8/13] v DLT 64.3% [9/14], p = ns), dislodgement during surgery (VDLT 38.5% [5/13] v DLT 21.4% [3/14], p = ns), and ability to forewarn dislodgement of endobronchial cuff (VDLT 18.4% [7/38] v DLT 4.8% [2/42], p = 0.078). This study demonstrated a reduction of 86.8% in FOB use, which was a similar reduction found in other published studies. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Learning nursing procedures: the influence of simulator fidelity and student gender on teaching effectiveness.

    PubMed

    Grady, Janet L; Kehrer, Rosemary G; Trusty, Carole E; Entin, Eileen B; Entin, Elliot E; Brunye, Tad T

    2008-09-01

    Simulation technologies are gaining widespread acceptance across a variety of educational domains and applications. The current research examines whether basic nursing procedure training with high-fidelity versus low-fidelity mannequins results in differential skill acquisition and perceptions of simulator utility. Fifty-two first-year students were taught nasogastric tube and indwelling urinary catheter insertion in one of two ways. The first group learned nasogastric tube and urinary catheter insertion using high-fidelity and low-fidelity mannequins, respectively, and the second group learned nasogastric tube and urinary catheter insertion using low-fidelity and high-fidelity mannequins, respectively. The dependent measures included student performance on nasogastric tube and urinary catheter insertion testing, as measured by observer-based instruments, and self-report questionnaires probing student attitudes about the use of simulation in nursing education. Results demonstrated higher performance with high-fidelity than with low-fidelity mannequin training. In response to a self-report posttraining questionnaire, participants expressed a more positive attitude toward the high-fidelity mannequin, especially regarding its responsiveness and realism.

  15. Reduced Feeding Tube Duration with IMRT for Head and Neck Cancer: A SEER-Medicare Analysis

    PubMed Central

    Beadle, Beth M.; Liao, Kai-Ping; Giordano, Sharon H.; Garden, Adam S.; Hutcheson, Katherine A.; Lai, Stephen Y.; Guadagnolo, B. Ashleigh

    2016-01-01

    Background Intensity-modulated radiation therapy (IMRT) is a technologically advanced and resource-intensive method of delivering radiation therapy (RT) used to minimize toxicity for patients with head and neck cancers (HNC). Dependence on feeding tubes is a significant marker of toxicity of RT. The goal of this analysis was to compare the placement and duration of feeding tube use for patients with HNC from 1999-2011. Methods The cohort, demographics, and cancer-related variables were determined using the linked Surveillance, Epidemiology, and End Results (SEER)-Medicare database and analyzed regarding treatment details using claims data. Results A total of 2993 patients were identified. With a median follow-up of 47 months, 54.4% of patients had a feeding tube placed. The median duration from feeding tube placement to removal was 277 days. On zero-inflated negative binomial regression, patients treated with IMRT and 3DRT (non-IMRT) had similar rates of feeding tube placement (odds ratio (OR) 1.10; p=.35); however, patients treated with 3DRT had the feeding tube in place 1.18 times longer than those treated with IMRT (p=.03). The difference was only seen amongst patients treated with definitive radiation; patients treated with surgery and adjuvant radiation had no statistically significant difference in placement or duration. Conclusions Patients with HNC treated with definitive IMRT had significantly shorter duration of feeding tubes in place than those treated with 3DRT. These data suggest that there may be significant quality of life benefits to IMRT with respect to long-term swallowing function for patients. PMID:27662641

  16. Use of radio frequency identification (RFID) tags in bedside monitoring of endotracheal tube position.

    PubMed

    Reicher, Joshua; Reicher, Danielle; Reicher, Murray

    2007-06-01

    Improper positioning of the endotracheal tube during intubation poses a serious health risk to patients. In one prospective study of 219 critically ill patients, 14% required endotracheal tube repositioning after intubation [Brunel et al. Chest 1989; 96: 1043-1045] While a variety of techniques are used to confirm proper tube placement, a chest X-ray is usually employed for definitive verification. Radio frequency identification (RFID) technology, in which an RFID reader emits and receives a signal from an RFID tag, may be useful in evaluating endotracheal tube position. RFID technology has already been approved for use in humans as a safe and effective tool in a variety of applications. The use of handheld RFID detectors and RFID tag-labeled endotracheal tubes could allow for easy and accurate bedside monitoring of endotracheal tube position, once initial proper placement is confirmed.

  17. Enteral tube feeding for cystic fibrosis.

    PubMed

    Conway, S P; Morton, A; Wolfe, S

    2008-04-16

    Enteral tube feeding is routinely used in many cystic fibrosis centres when weight for height percentage is less than 85%, when there has been weight loss for longer than a two-month period or when there has been no weight gain for two to three months (under five years old) or for six months (over five years old). To examine the evidence that in people with cystic fibrosis supplemental enteral tube feeding improves nutritional status, respiratory function, and quality of life without significant adverse effects. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register which comprises references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings. We also contacted the companies that market enteral feeds and reviewed their databases. Date of the most recent search of the Group's Cystic Fibrosis Trials Register: November 2007. All randomised controlled trials comparing supplemental enteral tube feeding for one month or longer with no specific intervention in people with cystic fibrosis. Thirteen trials were identified by the search; however, none were eligible for inclusion in this review. There are no trials included in this review. Supplemental enteral tube feeding is widely used throughout the world to improve nutritional status in people with cystic fibrosis. The methods mostly used, nasogastric or gastrostomy feeding, are invasive, expensive, and may have a negative effect on self-esteem and body image. Reported use of enteral tube feeding suggests that it results in nutritional and respiratory improvement and it is disappointing that their efficacy has not been fully assessed by randomised controlled trials. With the more frequent recommendations to use enteral tube feeding as an early rather than a late intervention, this systematic review identifies the need for a multicentre, randomised controlled trial assessing both efficacy and possible

  18. Outcomes of percutaneous endoscopic gastrostomy tube insertion in respiratory impaired amyotrophic lateral sclerosis patients under noninvasive ventilation.

    PubMed

    Czell, David; Bauer, Matthias; Binek, Janek; Schoch, Otto D; Weber, Markus

    2013-05-01

    Percutaneous endoscopic gastrostomy (PEG) tube placement in amyotrophic lateral sclerosis (ALS) patients with impaired respiratory function is associated with an increased risk of peri-procedural and post-interventional complications. It was the aim of the study to analyze peri- and post-interventional complications and survival after PEG tube placement under noninvasive ventilation (NIV) in ALS patients with various degrees of respiratory impairment. Twenty-six subjects were included in this retrospective case study. Prior to PEG tube placement, training with ventilatory support via an oronasal mask was performed with ALS subjects on the pneumology ward. PEG placement was then performed under continuous NIV. FVC, sniff nasal inspiratory pressure, and demographic data were assessed. Complication rates and 1-month and overall survival rates were analyzed. There were no deaths within 24 hours after PEG placement. One subject died within the first month. The mean survival rate after PEG was 12 ± 10 months (range 0.6-42 months). There was no difference in post-PEG survival between subjects with moderately (> 50%) and severely (< 50%) impaired FVC. In this case series, PEG tube insertion was associated with minimal peri- and post-procedural complications. The low complication rate might be due to the systematic use of procedural NIV in ALS subjects.

  19. Factors influencing decision regret regarding placement of a PEG among substitute decision-makers of older persons in Japan: a prospective study.

    PubMed

    Kuraoka, Yumiko; Nakayama, Kazuhiro

    2017-06-28

    A tube feeding decision aid designed at the Ottawa Health Research Institute was specifically created for substitute decision-makers who must decide whether to allow placement of a percutaneous endoscopic gastrostomy (PEG) tube in a cognitively impaired older person. We developed a Japanese version and found that the decision aid promoted the decision-making process of substitute decision-makers to decrease decisional conflict and increase knowledge. However, the factors that influence decision regret among substitute decision-makers were not measured after the decision was made. The objective of this study was to explore the factors that influence decision regret among substitute decision-makers 6 months after using a decision aid for PEG placement. In this prospective study, participants comprised substitute decision-makers for 45 inpatients aged 65 years and older who were being considered for placement of a PEG tube in hospitals, nursing homes and patients' homes in Japan. The Decisional Conflict Scale (DCS) was used to evaluate decisional conflict among substitute decision-makers immediately after deciding whether to introduce tube feeding and the Decision Regret Scale (DRS) was used to evaluate decisional regret among substitute decision-makers 6 months after they made their decision. Normalized scores were evaluated and analysis of variance was used to compare groups. The results of the multiple regression analysis suggest that PEG placement (P < .01) and decision conflict (P < .001) are explanatory factors of decision regret regarding placement of a PEG among substitute decision-makers. PEG placement and decision conflict immediately after deciding whether to allow PEG placement have an influence on decision regret among substitute decision-makers after 6 months.

  20. Replacement of Mushroom Cage Gastrostomy Tube Using a Modified Technique to Allow Percutaneous Replacement with an Endoscopic Tube in Patients with Amyotrophic Lateral Sclerosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ammar, Thoraya; Rio, Alan; Ampong, Mary Ann

    2010-06-15

    Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, withmore » modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.« less

  1. Estimation of optimal nasotracheal tube depth in adult patients.

    PubMed

    Ji, Sung-Mi

    2017-12-01

    The aim of this study was to estimate the optimal depth of nasotracheal tube placement. We enrolled 110 patients scheduled to undergo oral and maxillofacial surgery, requiring nasotracheal intubation. After intubation, the depth of tube insertion was measured. The neck circumference and distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch were measured. To estimate optimal tube depth, correlation and regression analyses were performed using clinical and anthropometric parameters. The mean tube depth was 28.9 ± 1.3 cm in men (n = 62), and 26.6 ± 1.5 cm in women (n = 48). Tube depth significantly correlated with height (r = 0.735, P < 0.001). Distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch correlated with depth of the endotracheal tube (r = 0.363, r = 0.362, and r = 0.546, P < 0.05). The tube depth also correlated with the sum of these distances (r = 0.646, P < 0.001). We devised the following formula for estimating tube depth: 19.856 + 0.267 × sum of the three distances (R 2 = 0.432, P < 0.001). The optimal tube depth for nasotracheally intubated adult patients correlated with height and sum of the distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch. The proposed equation would be a useful guide to determine optimal nasotracheal tube placement.

  2. Severe complications caused by dissolution of latex with consequent self-disintegration of esophageal plastic tubes.

    PubMed

    Löser, C

    2000-09-01

    A case of decisive material degeneration of an esophageal Celestin tube is described: a 50-year-old man with adenocarcinoma of the distal esophagus received a Celestin tube for palliative endoscopic treatment and 8 months later presented with suddenly occurring complete dysphagia. Dissolution of the latex layer in the proximal as well as the distal part of the tube had caused self-disintegration of the Celestin tube and had liberated the monofilament nylon coil which completely obstructed the lumen of the tube. Endoscopic tube removal was only possible by careful attachment of a balloon catheter and peroral extraction after insufflation with contrast medium up to 5 atm. A Medline-based review of the literature revealed different but predominantly severe complications (perforation, hemorrhage, obstruction, and peritonitis) based on material fatigue of the latex layer in esophageal Celestin tubes. At least 6 months after placement of a Celestin tube, regular fluoroscopic controls should be performed to detect early disintegration of the tube. Indication for the placement of Celestin tubes in patients with benign esophageal strictures and longer life expectancy should be assessed very critically.

  3. The Effect of Listening to Music During Percutaneous Nephrostomy Tube Placement on Pain, Anxiety, and Success Rate of Procedure: A Randomized Prospective Study.

    PubMed

    Hamidi, Nurullah; Ozturk, Erdem

    2017-05-01

    To evaluate the effect of listening to music on pain, anxiety, and success of procedure during office-based percutaneous nephrostomy tube placement (PNTP). One hundred consecutive patients (age >18 years) with hydronephrosis were prospectively enrolled in this study. All patients were prospectively randomized to undergo office-based PNTP with (Group I, n = 50) or without music (Group II, n = 50). Anxiety levels were evaluated with State Trait Anxiety Inventory. A visual analog scale was used to evaluate pain levels, patient's satisfaction, and willingness to undergo the procedure. We also compared success rates of procedures. The mean age, duration of procedure, and gender distribution were statistically similar between the two groups. The mean postprocedural heart rates and systolic blood pressures in Group I patients were significantly lower than Group II patients (p = 0.01 and p = 0.028, respectively), whereas preprocedural pulse rate and systolic blood pressure were similar. The mean anxiety level and mean pain score of Group I were significantly lower than those of Group II (p = 0.008 and p < 0.001, respectively). Group I also carried a significant greater mean satisfaction score and willingness to undergo repeat procedure compared with Group II (p < 0.001 for both). Success rate of nephrostomy tube placement in Group I was significantly higher compared with Group II (92% vs 66%, p = 0.04). The present randomized prospective study demonstrates that listening to music during office-based PNTP decreases anxiety or pain and increases success rate of procedure. As an alternative to sedation or general anesthesia, music is easily accessible without side effect and cost.

  4. A simple customized surgical guide for orthodontic miniplates with tube.

    PubMed

    Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2012-09-01

    This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.

  5. Transfer of adult Strongylus vulgaris via stomach tube.

    PubMed

    Hofing, G L; Bennett, D G

    1983-10-01

    Patent infections with Strongylus vulgaris were established in 6 of 8 helminth-free ponies given 41 to 101 adult worms via nasogastric tube. The parasites were removed from the cecum and ventral colon and transferred within 1 to 2 hours of the death of the donor horses. Eggs were found in the feces of the recipients in 2 or 3 days; egg counts reached maximum, 28 eggs per gram of feces, at 4 weeks after ponies were inoculated. In 6 ponies euthanatized 3 to 7 weeks after parasitic transfers were done, 28% of the inoculated worms were found alive at necropsy. A 7th pony was maintained as a donor for establishing infections for chemotherapy trials and, although never passing more than 6 eggs per gram of feces, shed infective larvae over a period of 2 years.

  6. Place Atrium to Water Seal (PAWS): Assessing Wall Suction Versus No Suction for Chest Tubes After Open Heart Surgery.

    PubMed

    Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue

    2017-08-01

    Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.

  7. Comparison of Medpor coated tear drainage tube versus silicon tear drainage tube in conjunctivodacryocystorhinostomy: problems and solutions.

    PubMed

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction.

  8. Comparison of Medpor Coated Tear Drainage Tube versus Silicon Tear Drainage Tube in Conjunctivodacryocystorhinostomy: Problems and Solutions

    PubMed Central

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    Purpose. This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Methods. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. Results. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. Conclusions. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction. PMID:25379518

  9. Orthodontic miniplate with tube as an efficient tool for borderline cases.

    PubMed

    Chung, Kyu-Rhim; Kim, Seong-Hun; Kang, Yoon-Goo; Nelson, Gerald

    2011-04-01

    An orthodontic miniplate tube device, the C-tube, was designed for use in patients for whom a conventional miniscrew is not suitable, such as those with narrow interradicular spaces, extended maxillary sinuses, dilacerated roots, or severe alveolar bone loss. After local anesthesia, 2 parallel horizontal incisions are made in the area of placement, and the periosteum is elevated. The C-tube is slipped under the mucosal flap and fixed with self-drilling miniscrews (diameter, 1.5 mm; length, 4 mm). Because the screws are short, there is adequate retention in the alveolar plate, and the clinician can avoid the increased morbidity of anchoring to the zygomatic buttress. This makes placement possible with superficial anesthesia. A small rolled tube at the head part can act as an orthodontic tube and accommodate archwires or as a hook to attach orthodontic elastics. However, in some patients with pneumatization or systemic diseases, such as diabetes mellitus, or in heavy smokers, cross-type C-tubes with longer miniscrews are recommend for better stability. This new type of orthodontic miniplate can be an effective alternative to conventional 1-component screws or miniplates in complex situations. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  10. Reassessment of the role of enteral tube feedings for patients with esophageal cancer.

    PubMed

    Starr, Brett; Davis, Stephanie; Ayala-Peacock, Diandra; Blackstock, William A; Levine, Edward A

    2014-08-01

    Nutrition is important for patients with esophageal cancer because dysphagia can be exacerbated by chemoradiotherapy. Some centers suggest routine enteral tube placement (TF) to facilitate nutrition. This investigation was to evaluate the use of TF access for patients undergoing multimodality therapy for esophageal carcinoma. This retrospective study analyzed 113 patients who underwent esophagectomy and 97 patients who underwent definition chemoradiotherapy for esophageal cancer between 2001 and 2013. Throughout this time period, a strategy for selective tube placement was used. Nutrition was assessed through absolute lymphocyte counts, protein, and albumin levels. A total of 28 (30%) patients during preoperative chemoradiotherapy and 31 (32%) of those undergoing definitive chemoradiation received TFs. There were 16 Dobhoff tubes, 28 gastrostomy tubes, and 15 jejunostomies. Tubes were maintained an average of 3.9 months with 20 (34%) of these patients reporting tube-related complications. At the time of surgery, there was no statistical difference in any of the nutritional assessments between those patients who received TF and those who did not. Both groups experienced similar total postoperative complication rates (64% vs 65%) and similar median length of hospital stay (12 to 13 days). Chemoradiotherapy resulted in decreased nutritional parameters; however, there was no difference in the degree of reduction between those who underwent TF and those who did not. The data show that routine placement of enteral access is not necessary for esophageal carcinoma. In fact, the risks of placing enteral access may outweigh the benefits. Administration of TF should be restricted to select patients during chemoradiotherapy or before esophagectomy.

  11. [Role of the small intestinal decompression tube and Gastrografin in the treatment of early postoperative inflammatory small bowel obstruction].

    PubMed

    Li, Wei; Li, Zhixia; An, Dali; Liu, Jing; Zhang, Xiaohu

    2014-03-01

    To evaluate the role of the small intestinal decompression tube (SIDT) and Gastrografin in the treatment of early postoperative inflammatory small bowel obstruction (EPISBO). Twelve patients presented EPISBO after abdominal surgery in our department from April 2011 to July 2012. Initially, nasogastric tube decompression and other conventional conservative treatment were administrated. After 14 days, obstruction symptom improvement was not obvious, then the SIDT was used. At the same time, Gastrografin was injected into the small bowel through the SIDT in order to demonstrate the site of obstruction of small bowel and its efficacy. In 11 patients after this management, obstruction symptoms disappeared, bowel function recovered within 3 weeks, and oral feeding occurred gradually. Another patient did not pass flatus after 4 weeks and was reoperated. After postoperative follow-up of 6 months, no case relapsed with intestinal obstruction. For severe and long course of early postoperative inflammatory intestinal obstruction, intestinal decompression tube plus Gastrografin is safe and effective, and can avoid unnecessary reoperation.

  12. Utility of feeding jejunostomy tubes in pancreaticoduodenectomy.

    PubMed

    Waliye, Hussein E; Wright, G Paul; McCarthy, Caitlin; Johnson, Jared; Scales, Alex; Wolf, Andrea; Chung, Mathew

    2017-03-01

    Routine placement of jejunostomy tubes (JT) during pancreaticoduodenectomy (PD) is controversial. A retrospective chart review of patients undergoing PD from 1/1/08 through 12/31/14 was performed. The patients were divided into groups by placement of JT. Outcome measures were 90-day morbidity, 90-day mortality, length of stay, rate of delayed gastric emptying (DGE), and JT-specific complications. 256 patients were included. There were no significant differences in 90-day morbidity (39.9% vs. 37.9%, p = 0.747), 90-day mortality (3.9% vs. 1.0%, p = 0.247) or TPN use (24.8 vs. 25.2%, p = 0.941) between those with and without JT, respectively. Patients with a JT had a higher rate of DGE (p < 0.001), longer hospital stay (14.3 vs. 11.6, p < 0.001), and longer time to solid intake (9.4 vs. 7.3, p < 0.001). Eleven patients (7.2%) with JT had tube-related morbidity. Routine placement of JT at the time of PD should be abandoned with efforts focused on preoperative nutrition optimization and early oral diet trials. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Miniplate With a Bendable C-Tube Head Allows the Clinician to Alter Biomechanical Advantage in Extremely Complicated Anatomic Structure.

    PubMed

    Seo, Kyung Won; Iskenderoglu, Nur Serife; Hwang, Eui Hwan; Chung, Kyu-Rhim; Kim, Seong-Hun

    2017-05-01

    This article reports C-tube miniplates as a practical temporary anchorage device choice to treat open bite patients with maxillary sinus pneumatization. The C-tube components are titanium anchor plates and monocortical screws that are basically similar to any other miniplate systems, but it has the unique characteristic of the tube head to be malleable. The manipulation of the head part is easy due to the composition of pure titanium. The I-shaped C-tube with 3 holes and T-shaped C-tube miniplates were placed above the apices of maxillary molars as an absolute anchorage system to intrude the posterior maxilla. The bending of the tube heads assisted in reduction of severe open bite patient with maxillary sinus pneumatization. Sinus perforation during placement of skeletal anchorage system weakens stability of the anchorage and further cause complications. Placement of titanium C-tube miniplates allowed reliable skeletal anchorage and avoided maxillary sinus perforation in patients with extreme pneumatizations. Simple bending of C-tube miniplates ensured increased orthodontic intrusion force without having to replace them, and eliminated consequences such as perforation of maxillary sinus, sinusitis, soft tissue irritation, or infection. Anatomic difficulties in the placement of temporary anchorage device can be easily managed by using the bendable C-tube miniplate. It can serve as a great alternative over miniscrews or regular miniplates with reduced risk of sinus perforation and ability to bend the head portion to control orthodontic vectors and forces.

  14. Chest tube management following pulmonary lobectomy: change of protocol results in fewer air leaks.

    PubMed

    Bertholet, Joost W M; Joosten, Joris J A; Keemers-Gels, Mariël E; van den Wildenberg, Frits J H; Barendregt, Wouter B

    2011-01-01

    Much controversy exists regarding the management of chest tubes following pulmonary lobectomy. The objective of this study was to analyse the effect of a new chest tube management protocol on clinical features, such as postoperative air leak, drain characteristics, 30-day postoperative complications and length of hospital stay. We retrospectively analysed 133 patients who underwent pulmonary lobectomy, from January 2005 to December 2008. A new chest tube protocol was introduced on 1 January 2007 and included placement of a single chest tube and early conversion to water seal. The chest tube was removed when air leak had resolved and (non-chylous) fluid drainage was <400 ml/day. The results of patients in the old (n=68) and the new protocol (n=65) were compared. In the new protocol group the median duration of air leak and duration of chest tube drainage declined significantly. Also the length of hospital stay decreased significantly to a median of eight days. The number of reinterventions and 30-day morbidity and mortality rates did not differ significantly. Our data suggest that placement of a single chest tube and early conversion to water seal decreases the duration of air leak and chest tube drainage and length of hospital stay.

  15. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    PubMed Central

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  16. Use of the silicone tracheal T-tube for tracheostenosis or tracheomalacia.

    PubMed

    Liu, H C; Wang, L S; Fahn, H J; Lee, Y C; Lu, C C; Chan, K H; Huang, M H

    1996-09-01

    Tracheobtenosib and tracheomalacia are trivial diseases. The conventional choice of managements with tracheostomy, either temporary or long-term usage, can only partially resolve the problems of airway obstruction. Silicone tracheal T-tube presents a substitute for it. We present 5 patients with tracheostenosis or tracheomalacia managed with nine procedures of long silicone Montgomery T-tube prothesis between 1984 and 1994 in VGH-Taipei. The primary diagnosis included tracheal injury (2), postintubation tracheal stenosis (2), and stenosis due to endotracheal tuberculosis (1). Three patients received a long segmental T-tube for permanent endotracheal stenting and the other two patients used T-tube insertion for temporary stenting of the trachea for 7 and 11 months, respectively, with satisfactory results. All patients got immediate benefit from the prothesis in respiration with simple postoperative care. Two patients with temporary T-tube placement had it successfully removed in 7 and 11 months, respectively. Placement of the T-tube for subglottic stenosis also protected the function of phonation. The tracheal T-tube restored airway patency reliably with good long-term results and could be the preferred management of chronic upper airway obstructive disease not amenable to surgical repair. The most common complication was airway obstruction caused by either granulations or sticky mucoid substance. Three patients and six tubes (60%) developed granulation obstruction and the average duration of granuloma formation was 7.7 months. Laser phototherapy or surgical intervention, such as tracheoplasty, with change of the T-tube was carried out for granuloma obstruction. T-tube is a good endoprothesis for tracheostenosis and tracheomalacia with minimal complication for cases of long tracheostenosis or complex tracheal injury.

  17. [A clinical study using octreotide in relieving gastrointestinal symptoms due to bowel obstruction in a terminally ill cancer patient].

    PubMed

    Shima, Yasuo; Yamaguchi, Kensei; Miyata, Yoshinori; Hyodo, Ichinosuke; Yagi, Yasuo; Honke, Yoshifumi

    2004-09-01

    Terminally ill cancer patients with complicated bowel obstructions often have poor quality of life (QOL) due to gastrointestinal symptoms such as nausea and vomiting. Many of these patients are inoperable because of poor general conditions, and half of these patients can't be managed by conventional antiemetics. There are many reports indicating octreotide is effective for these patients. In the present study, 13 patients (5 patients without a nasogastric tube and 8 patients with) were administered octreotide at 300 microg/day by 24 hours continuous subcutaneous infusion. Among the effectively evaluable 10 cases, 6 cases (60.0%) were assessed as effective according to the efficacy criteria based on the JCOG toxicity scale. In the 6 cases who had nasogastric tubes, the nasogastric aspirates decreased from 890 ml (550-1,950) to 480 ml (180-1,790). Vomiting was successfully controlled after the removals of nasogastric tubes in 4 out of 6 cases (66.7%), regarding safety, 2 out of 13 cases (15.4%) showed an excess of liver enzymes but no clinically suspected adverse effect was observed. Octreotide is effective and well tolerated in terminally ill cancer patients with malignant bowel obstruction.

  18. Tracheal palpation to assess endotracheal tube depth: an exploratory study.

    PubMed

    McKay, William P; Klonarakis, Jim; Pelivanov, Vladko; O'Brien, Jennifer M; Plewes, Chris

    2014-03-01

    Correct placement of the endotracheal tube (ETT) occurs when the distal tip is in mid-trachea. This study compares two techniques used to place the ETT at the correct depth during intubation: tracheal palpation vs placement at a fixed depth at the patient's teeth. With approval of the Research Ethics Board, we recruited American Society of Anesthesiologists physical status I-II patients scheduled for elective surgery with tracheal intubation. Clinicians performing the tracheal intubations were asked to "advance the tube slowly once the tip is through the cords". An investigator palpated the patient's trachea with three fingers spread over the trachea from the larynx to the sternal notch. When the ETT tip was felt in the sternal notch, the ETT was immobilized and its position was determined by fibreoptic bronchoscopy. The position of the ETT tip was compared with our hospital standard, which is a depth at the incisors or gums of 23 cm for men and 21 cm for women. The primary outcome was the incidence of correct placement. Correct placement of the ETT was defined as a tip > 2.5 cm from the carina and > 3.5 cm below the vocal cords. Movement of the ETT tip was readily palpable in 77 of 92 patients studied, and bronchoscopy was performed in 85 patients. Placement by tracheal palpation resulted in more correct placements (71 [77%]; 95% confidence interval [CI] 74 to 81) than hospital standard depth at the incisors or gums (57 [61%]; 95% CI 58 to 66) (P = 0.037). The mean (SD) placement of the ETT tip in palpable subjects was 4.1 (1.7) cm above the carina, 1.9 cm (1.5-2.3 cm) below the ideal mid-tracheal position. Tracheal palpation requires no special equipment, takes only a few seconds to perform, and may improve ETT placement at the correct depth. Further studies are warranted.

  19. Randomised clinical trial investigating the effects of combined administration of octreotide and methylglucamine diatrizoate in the older persons with adhesive small bowel obstruction.

    PubMed

    Zhang, Y; Gao, Y; Ma, Q; Dang, C; Wei, W; De Antoni, F; Rocci, R; Chen, W

    2006-03-01

    To investigate the effects of combined administration of octreotide and methylglucamine diatrizoate in the older persons with adhesive small bowel obstruction. One hundred and sixty-two consecutive patients who had suffered from adhesive intestinal obstruction without clinical evidence of strangulation or gangrene were randomised into two groups, a control group (treated conservatively, n=82) and a contrast group (treated with combined administration of octreotide and methylglucamine diatrizoate, n=80). A laparotomy was performed in both the two groups if symptoms of strangulation developed or the obstruction did not resolve spontaneously after 72 h. Statistically significant rapid reduction in pain score, lower amount of nasogastric drainage, shorter hospital stay, lower operative rate and lower postoperative morbidity were observed in the contrast group. Among the non-operative patients, earlier passage of stool and gas, earlier first oral intake and shorter duration of nasogastric tube placement were significantly more frequently observed in the contrast group. No difference in the rate of readmission was found between the two groups. Combined administration of octreotide and methylglucamine diatrizoate accelerates resolution of small bowel obstruction by a specific therapeutic effect and is safe for the older persons.

  20. Detecting tympanostomy tubes from otoscopic images via offline and online training.

    PubMed

    Wang, Xin; Valdez, Tulio A; Bi, Jinbo

    2015-06-01

    Tympanostomy tube placement has been commonly used nowadays as a surgical treatment for otitis media. Following the placement, regular scheduled follow-ups for checking the status of the tympanostomy tubes are important during the treatment. The complexity of performing the follow up care mainly lies on identifying the presence and patency of the tympanostomy tube. An automated tube detection program will largely reduce the care costs and enhance the clinical efficiency of the ear nose and throat specialists and general practitioners. In this paper, we develop a computer vision system that is able to automatically detect a tympanostomy tube in an otoscopic image of the ear drum. The system comprises an offline classifier training process followed by a real-time refinement stage performed at the point of care. The offline training process constructs a three-layer cascaded classifier with each layer reflecting specific characteristics of the tube. The real-time refinement process enables the end users to interact and adjust the system over time based on their otoscopic images and patient care. The support vector machine (SVM) algorithm has been applied to train all of the classifiers. Empirical evaluation of the proposed system on both high quality hospital images and low quality internet images demonstrates the effectiveness of the system. The offline classifier trained using 215 images could achieve a 90% accuracy in terms of classifying otoscopic images with and without a tympanostomy tube, and then the real-time refinement process could improve the classification accuracy by 3-5% based on additional 20 images. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Incidence of Tube Feeding in 7174 Newly Admitted Nursing Home Residents With and Without Dementia.

    PubMed

    Schulze, Jana; Mazzola, Rosa; Hoffmann, Falk

    2016-02-01

    Tube feeding is a common form of long-term nutritional support, especially for nursing home residents, of whom many have dementia. Estimating the incidence of feeding tube placement in nursing home residents with and without dementia. Using claims data, we studied a cohort of newly admitted nursing home residents aged 65 years and older between 2004 and 2009. Analyses were stratified by dementia. We estimated incidence rates and performed multivariate Cox regression analyses. The study cohort included 7174 nursing home residents. Over a mean follow-up of 1.3 years, 273 people received a feeding tube. The incidence per 1000 person-years was 28.4, with higher estimates for patients with dementia. When adjusting for age, sex, and level of care as a time-dependent covariate, influence of dementia decreased to a nonsignificant hazard ratio. It seems that not dementia itself but the overall clinical condition might be a predictor of tube feeding placement. © The Author(s) 2015.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koyfman, Shlomo A., E-mail: koyfmas@ccf.org; Adelstein, David J.

    Definitive chemoradiation therapy has evolved as the preferred organ preservation strategy in the treatment of locally advanced head-and-neck cancer (LA-HNC). Dry mouth and dysphagia are among the most common and most debilitating treatment-related toxicities that frequently necessitate the placement of enteral feeding tubes (FT) in these patients to help them meet their nutritional requirements. The use of either a percutaneous endoscopic gastrostomy tube or a nasogastric tube, the choice of using a prophylactic vs a reactive approach, and the effects of FTs on weight loss, hospitalization, quality of life, and long-term functional outcomes are areas of continued controversy. Considerable variationsmore » in practice patterns exist in the United States and abroad. This critical review synthesizes the current data for the use of enteral FTs in this patient population and clarifies the relative advantages of different types of FTs and the timing of their use. Recent developments in the biologic understanding and treatment approaches for LA-HNC appear to be favorably impacting the frequency and severity of treatment-related dysphagia and may reduce the need for enteral tube feeding in the future.« less

  3. Design of 3-D Printed Concentric Tube Robots.

    PubMed

    Morimoto, Tania K; Okamura, Allison M

    2016-12-01

    Concentric tube surgical robots are minimally invasive devices with the advantages of snake-like reconfigurability, long and thin form factor, and placement of actuation outside the patient's body. These robots can also be designed and manufactured to acquire targets in specific patients for treating specific diseases in a manner that minimizes invasiveness. We propose that concentric tube robots can be manufactured using 3-D printing technology on a patient- and procedure-specific basis. In this paper, we define the design requirements and manufacturing constraints for 3-D printed concentric tube robots and experimentally demonstrate the capabilities of these robots. While numerous 3-D printing technologies and materials can be used to create such robots, one successful example uses selective laser sintering to make an outer tube with a polyether block amide and uses stereolithography to make an inner tube with a polypropylene-like material. This enables a tube pair with precurvatures of 0.0775 and 0.0455 mm -1 , which can withstand strains of 20% and 5.5% for the outer and inner tubes, respectively.

  4. Design of 3-D Printed Concentric Tube Robots

    PubMed Central

    Morimoto, Tania K.; Okamura, Allison M.

    2017-01-01

    Concentric tube surgical robots are minimally invasive devices with the advantages of snake-like reconfigurability, long and thin form factor, and placement of actuation outside the patient’s body. These robots can also be designed and manufactured to acquire targets in specific patients for treating specific diseases in a manner that minimizes invasiveness. We propose that concentric tube robots can be manufactured using 3-D printing technology on a patient- and procedure-specific basis. In this paper, we define the design requirements and manufacturing constraints for 3-D printed concentric tube robots and experimentally demonstrate the capabilities of these robots. While numerous 3-D printing technologies and materials can be used to create such robots, one successful example uses selective laser sintering to make an outer tube with a polyether block amide and uses stereolithography to make an inner tube with a polypropylene-like material. This enables a tube pair with precurvatures of 0.0775 and 0.0455 mm−1, which can withstand strains of 20% and 5.5% for the outer and inner tubes, respectively. PMID:28713227

  5. Mediastinal hemorrhage: An evaluation of radiographic manifestations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodring, J.H.; Loh, F.K.; Kryscio, R.J.

    1984-04-01

    Eleven common radiographic signs of mediastinal hemorrhage were evaluated by two observers for the following three patient groups: normal subjects, patients with mediastinal hemorrhage and no arterial injury, and patients with major thoracic arterial injury. Supine chest radiographs were studied in all cases. Four major conclusions can be made based upon these finding. M/C ratio (mediastinal width to chest width), tracheal deviation, left hemothorax, paraspinal line widening, and aorto-pulmonary window opacification do not reliably separate these three groups of patients. The diagnosis of mediastinal hemorrhage may be made if the aortic contour is abnormal or if one of the followingmore » signs is positive: abnormal mediastinal width, apical cap, widening of the right paratracheal stripe, or deviation of the nasogastric tube. Due to interobserver variation, there is good agreement between observers for the following four signs only: transverse mediastinal width, tracheal deviation, nasogastric tube deviation, nasogastric tube deviation, and right paratracheal stripe widening.« less

  6. The Impact of Tympanostomy Tubes on Speech and Language Development in Children with Cleft Palate.

    PubMed

    Shaffer, Amber D; Ford, Matthew D; Choi, Sukgi S; Jabbour, Noel

    2017-09-01

    Objective Describe the impact of hearing loss, tympanostomy tube placement before palatoplasty, and number of tubes received on speech outcomes in children with cleft palate. Study Design Case series with chart review. Setting Tertiary care children's hospital. Subjects and Methods Records from 737 children born between April 2005 and April 2015 who underwent palatoplasty at a tertiary children's hospital were reviewed. Exclusion criteria were cleft repair at an outside hospital, intact secondary palate, absence of postpalatoplasty speech evaluation, sensorineural or mixed hearing loss, no tubes, first tubes after palatoplasty, or first clinic after 12 months of age. Data from 152 patients with isolated cleft palate and 166 patients with cleft lip and palate were analyzed using Wilcoxon rank-sum, χ 2 , and Fisher exact test and logistic regression. Results Most patients (242, 76.1%) received tubes before palatoplasty. Hearing loss after tubes, but not before, was associated with speech/language delays at 24 months ( P = .005) and language delays ( P = .048) and speech sound production disorders (SSPDs, P = .040) at 5 years. Receiving tubes before palatoplasty was associated with failed newborn hearing screen ( P = .001) and younger age at first posttubes type B tympanogram with normal canal volume ( P = .015). Hearing loss after tubes ( P = .021), language delays ( P = .025), SSPDs ( P = .003), and velopharyngeal insufficiency ( P = .032) at 5 years and speech surgery ( P = .022) were associated with more tubes. Conclusion Continued middle ear disease, reflected by hearing loss and multiple tubes, may impair speech and language development. Inserting tubes before palatoplasty did not mitigate these impairments better than later tube placement.

  7. Changes in the distance between carina and orotracheal tube during open or videolaparoscopic bariatric surgery.

    PubMed

    de Figueiredo Locks, Giovani; Simões de Almeida, Maria Cristina; Sperotto Ceccon, Maurício; Campos Pastório, Karen Adriana

    2015-01-01

    To examine whether there are changes in the distance between the orotracheal tube and carina induced by orthostatic retractor placement or by pneumoperitoneum insufflation in obese patients undergoing gastroplasty. 60 patients undergoing bariatric surgery by two techniques: open (G1) or videolaparoscopic (G2) gastroplasty were studied. After tracheal intubation, adequate ventilation of both hemitoraxes was confirmed by lung auscultation. The distance orotracheal tube-carina was estimated with the use of a fiber bronchoscope before and after installation of orthostatic retractors in G1 or before and after insufflation of pneumoperitoneum in patients in G2. G1 was composed of 22 and G2 of 38 patients. No cases of endobronchial intubation were detected in either group. The mean orotracheal tube-carina distance variation was estimated in -0.03cm (95% CI 0.06 to -0.13) in the group of patients undergoing open gastroplasty and in -0.42cm (95% CI -0.56 to -1.4) in the group of patients undergoing videolaparoscopic gastroplasty. The extremes of variation in each group were: 0.5cm to -1.6cm in patients undergoing open surgery and 0.1cm to -2.2cm in patients undergoing videolaparoscopic surgery. There was no significant change in orotracheal tube-CA distance after placement of orthostatic retractors in patients undergoing open gastroplasty. There was a reduction in orotracheal tube-CA distance after insufflation of pneumoperitoneum in patients undergoing videolaparoscopic gastroplasty. We recommend attention to lung auscultation and to signals of ventilation monitoring and reevaluation of orotracheal tube placement after peritoneal insufflation. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  8. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    PubMed

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding.

    PubMed

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-07-07

    To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.

  10. Esophageal stricture - benign

    MedlinePlus

    Esophageal stricture can be caused by: Gastroesophageal reflux (GERD). Eosinophilic esophagitis. Injuries caused by an endoscope . Long-term use of a nasogastric (NG) tube (tube through the nose into the ...

  11. Virtually fabricated guide for placement of the C-tube miniplate.

    PubMed

    Paek, Janghyun; Jeong, Do-Min; Kim, Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2014-05-01

    This paper introduces a virtually planned and stereolithographically fabricated guiding system that will allow the clinician to plan carefully for the best location of the device and to achieve an accurate position without complications. The scanned data from preoperative dental casts were edited to obtain preoperative 3-dimensional (3D) virtual models of the dentition. After the 3D virtual models were repositioned, the 3D virtual surgical guide was fabricated. A surgical guide was created onscreen, and then these virtual guides were materialized into real ones using the stereolithographic technique. Whereas the previously described guide required laboratory work to be performed by the orthodontist, our technique is more convenient because the laboratory work is done remotely by computer-aided design/computer-aided manufacturing technology. Because the miniplate is firmly held in place as the patient holds his or her mandibular teeth against the occlusal pad of the surgical guide, there is no risk that the miniscrews can slide on the bone surface during placement. The software program (2.5-dimensional software) in this study combines 2-dimensional cephalograms with 3D virtual dental models. This software is an effective and efficient alternative to 3D software when 3D computed tomography data are not available. To confidently and safely place a miniplate with screw fixation, a simple customized guide for an orthodontic miniplate was introduced. The use of a custom-made, rigid guide when placing miniplates will minimize complications such as vertical mislocation or slippage of the miniplate during placement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  12. Comparison of digital and traditional thoracic drainage systems for postoperative chest tube management after pulmonary resection: A prospective randomized trial.

    PubMed

    Takamochi, Kazuya; Nojiri, Shuko; Oh, Shiaki; Matsunaga, Takeshi; Imashimizu, Kota; Fukui, Mariko; Suzuki, Kenji

    2018-04-01

    The objective of this study was to evaluate whether a digital thoracic drainage system (group D) is clinically useful compared with a traditional thoracic drainage system (group T) in chest tube management following anatomic lung resection. Patients scheduled to undergo segmentectomy or lobectomy were prospectively randomized before surgery to group D or T. A stratification randomization was performed according to the following air leak risk factors: age, sex, smoking status, and presence of emphysema and/or chronic obstructive pulmonary disease. The primary end point was the duration of chest tube placement. No statistically significant differences were found between groups D (n = 135) and T (n = 164) with regard to the duration of chest tube placement (median, 2.0 vs 3.0 days; P = .149), duration of hospitalization (median, 6.0 vs 7.0 days; P = .548), or frequency of postoperative adverse events (25.1% vs 20.7%; P = .361). In subgroup analyses of the 64 patients with postoperative air leak (20 in group D and 44 in group T), the duration of chest tube placement (median, 4.5 vs 4.0 days; P = .225) and duration of postoperative air leak (median, 3.0 vs 3.0 days; P = .226) were not significantly different between subgroups. The use of a digital thoracic drainage system did not shorten the duration of chest tube placement in comparison to a traditional thoracic drainage system after anatomic lung resection. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Steroid Versus Antibiotic Drops in the Prevention of Postoperative Myringotomy Tube Complications.

    PubMed

    Alvi, Sameer A; Jones, Joel W; Porter, Paul; Perryman, Mollie; Nelson, Karen; Francis, Carrie L; Larsen, Christopher G

    2018-07-01

    To determine the incidence of early postoperative tympanostomy tube insertion otorrhea and obstruction in pediatric patients receiving antibiotic ear drops with or without steroid perioperatively. A retrospective chart review was performed on patients who underwent outpatient myringotomy and tube placement. Patients from June 2013 to February 2014 received ciprofloxacin/dexamethasone perioperatively while patients from May 2014 to April 2015 received ofloxacin. Statistical analysis was performed to compare outcomes between the cohorts. One hundred thirty-four patients received topical ciprofloxacin/dexamethasone, and 116 patients received topical ofloxacin. The rate of postoperative otorrhea was 5.2% for the ciprofloxacin/dexamethasone group and 8.2% for the ofloxacin group. Tube obstruction was seen in 6.0% of the ciprofloxacin/dexamethasone group and 5.2% in the ofloxacin group. Neither outcome had a statistically significant difference ( P = .21 and .85, respectively). There was no difference in the rate of effusion at the time of tube placement between the 2 cohorts ( P = .16), and this included subgroup analysis based on effusion type (mucoid, purulent, serous). Patients with a mucoid effusion at the time of surgery were more likely to experience otorrhea/obstruction than patients with dry ears (odds ratio = 2.23, P = .02). No significant difference in the incidence of immediate postoperative tympanostomy tube otorrhea or obstruction was seen between the antibiotic-steroid and antibiotic alone cohorts, regardless of effusion type. Overall, patients with mucoid effusions are more likely to develop tube otorrhea or obstruction at follow-up. Cost-effective drops should be used when prescribing topical therapy to prevent complications after ear tubes.

  14. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    PubMed

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  15. Feeding tubes and health costs postinsertion in nursing home residents with advanced dementia.

    PubMed

    Hwang, Deborah; Teno, Joan M; Gozalo, Pedro; Mitchell, Susan

    2014-06-01

    The best evidence suggests that feeding tubes are ineffective in persons with advanced dementia. Little is known about their health care costs. To estimate Medicare costs attributable to inpatient care among nursing home (NH) residents with advanced dementia during the year following the placement of a percutaneous endoscopic gastrostomy (PEG) tube during an index hospitalization. Medicare claims (1999-2009) and Minimum Data Set data (1999-2009) were used to estimate Medicare costs attributable to inpatient care among NH residents with advanced dementia during the year following the placement of a PEG tube and compared with those who did not get a PEG tube. The study used a 3:1 propensity-matched cohort design. Matched residents with (n=1924, 68.9% female, 28.8% African American, average age 83.1 years) and without (weighted n=1924, unique n=4337) PEG insertion showed comparable sociodemographic characteristics, similar rates of feeding tube risk factors, and similar mortality (51.9% 180 day mortality among those with a feeding tube vs. 49.8% among those without a feeding tube, P=0.11). One year hospital costs were $2224 higher in NH residents with a feeding tube ($10,191 vs. $7967, 95% CI of difference=$1514, $2933), with those with a feeding tube likely to spend more time in an intensive care unit (1.92 vs. 1.29 days, 95% CI of difference=0.34, 0.92 days). In an analysis controlling for selection bias, PEG tube insertion is associated with a small but significant increase in annual inpatient health care costs, as well as in hospital and intensive care unit days, postinsertion. Copyright © 2014 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.

  16. Replacement of Dislodged Gastrostomy Tubes After Stoma Dilation in the Pediatric Emergency Department.

    PubMed

    Bhambani, Shiloni; Phan, Tammy H; Brown, Lance; Thorp, Andrea W

    2017-06-01

    A dislodged gastrostomy tube (GT) is a common complaint that requires evaluation in the pediatric emergency department (ED) and, on occasion, will require stoma dilation to successfully replace the GT. The objective of this study was to describe the frequency that stoma dilation is required, the success rate of replacement, complications encountered, and the techniques used to confirm placement of the GT after dilation. We conducted a retrospective medical record review of children 0-18 years who presented to the pediatric ED from February 2013 through February 2015 with a dislodged GT that required stoma dilation by pediatric emergency physicians with serially increasing Foley catheter sizes prior to successful placement of the GT. We reviewed a total of 302 encounters in 215 patients, with 97 (32%) of the encounters requiring stoma dilation prior to replacing a GT. The median amount of dilation was 2 French between the initial Foley catheter size and the final GT size. There was a single complication of a mal-positioned balloon that was identified at the index visit. No delayed complications were encountered. We performed confirmation of placement in all patients. The two most common forms of confirmation were aspiration of gastric contents (56/97 [58%]) followed by contrast radiograph in 39 (40%). The practice of serial dilation of a gastrostomy stoma site to allow successful replacement of a gastrostomy tube in pediatric patients who present to the ED with a dislodged gastrostomy tube is generally successful and without increased complication. All patients received at least one form of confirmation for appropriate GT placement with the most common being aspiration of gastric contents.

  17. A prospective randomised trial comparing nasogastric with intravenous hydration in children with bronchiolitis (protocol) The comparative rehydration in bronchiolitis study (CRIB)

    PubMed Central

    2010-01-01

    Background Bronchiolitis is the most common reason for admission of infants to hospital in developed countries. Fluid replacement therapy is required in about 30% of children admitted with bronchiolitis. There are currently two techniques of fluid replacement therapy that are used with the same frequency-intravenous (IV) or nasogastric (NG). The evidence to determine the optimum route of hydration therapy for infants with bronchiolitis is inadequate. This randomised trial will be the first to provide good quality evidence of whether nasogastric rehydration (NGR) offers benefits over intravenous rehydration (IVR) using the clinically relevant continuous outcome measure of duration of hospital admission. Methods/Design A prospective randomised multi-centre trial in Australia and New Zealand where children between 2 and 12 months of age with bronchiolitis, needing non oral fluid replacement, are randomised to receive either intravenous (IV) or nasogastric (NG) rehydration. 750 patients admitted to participating hospitals will be recruited, and will be followed daily during the admission and by telephone 1 week after discharge. Patients with chronic respiratory, cardiac, or neurological disease; choanal atresia; needing IV fluid resuscitation; needing an IV for other reasons, and those requiring CPAP or ventilation are excluded. The primary endpoint is duration of hospital admission. Secondary outcomes are complications, need for ICU admission, parental satisfaction, and an economic evaluation. Results will be analysed using t-test for continuous data, and chi squared for categorical data. Non parametric data will be log transformed. Discussion This trial will define the role of NGR and IVR in bronchiolitis Trail registration The trial is registered with the Australian and New Zealand Clinical Trials Registry - ACTRN12605000033640 PMID:20515467

  18. Middle ear findings and need for ventilation tubes among pediatric cleft lip and palate patients in northern Finland.

    PubMed

    Lehtonen, Ville; Lithovius, Riitta H; Autio, Timo J; Sándor, George K; Ylikontiola, Leena P; Harila, Virpi; Pesonen, Paula; Koskinen, Sari; Anttonen, Vuokko

    2016-04-01

    Middle ear problems are common in cleft patients. This study aimed to determine the need for ventilation tubes (VTs) and complications such as tympanic perforation and cholesteatoma. Data of 156 children with clefts managed in northern Finland spanning 15 years from 1997 to 2011 were collected from 6 hospitals. The following were recorded: birth date, gender, cleft type, surgery timing, surgery type, number of tube insertions, tube material, middle ear findings, and tube placement timing. Clefts were divided into 4 groups: cleft palate (CP), cleft lip and palate (CLP), cleft lip (CL), and submucous cleft palate. The prevalence of middle ear findings was reported. Mucous secretion was noted in 96.8% of CLP patients, 69.2% of CP patients, and 13.0% of CL patients. In all, 82.7% of study group had 1 or more VTs placed during follow-up. All CLP patients required more than 1 VT placement. A total of 94.5% of CP patients required VTs compared to 13.0% of CL patients. In the presence of residual oral nasal fistula, the mean number of tube insertions was 5.3. The prevalence of tympanic perforations in clefts was 35.9% and cholesteatoma in 2.6% of patients. CLP and isolated CP patients have frequent middle ear infections requiring multiple VT placements. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay; Ensor, Joe E.

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if themore » absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.« less

  20. Medication administration through enteral feeding tubes.

    PubMed

    Williams, Nancy Toedter

    2008-12-15

    An overview of enteral feeding tubes, drug administration techniques, considerations for dosage form selection, common drug interactions with enteral formulas, and methods to minimize tube occlusion is given. Enteral nutrition through a feeding tube is the preferred method of nutrition support in patients who have a functioning gastrointestinal tract but who are unable to be fed orally. This method of delivering nutrition is also commonly used for administering medications when patients cannot swallow safely. However, several issues must be considered with concurrent administration of oral medications and enteral formulas. Incorrect administration methods may result in clogged feeding tubes, decreased drug efficacy, increased adverse effects, or drug-formula incompatibilities. Various enteral feeding tubes are available and are typically classified by site of insertion and location of the distal tip of the feeding tube. Liquid medications, particularly elixirs and suspensions, are preferred for enteral administration; however, these formulations may be hypertonic or contain large amounts of sorbitol, and these properties increase the potential for adverse effects. Before solid dosage forms are administered through the feeding tube, it should be determined if the medications are suitable for manipulation, such as crushing a tablet or opening a capsule. Medications should not be added directly to the enteral formula, and feeding tubes should be properly flushed with water before and after each medication is administered. To minimize drug-nutrient interactions, special considerations should be taken when administering phenytoin, carbamazepine, warfarin, fluoroquinolones, and proton pump inhibitors via feeding tubes. Precautions should be implemented to prevent tube occlusions, and immediate intervention is required when blockages occur. Successful drug delivery through enteral feeding tubes requires consideration of the tube size and placement as well as careful

  1. Transanal drainage tube reduces rate and severity of anastomotic leakage in patients with colorectal anastomosis: A case controlled study.

    PubMed

    Brandl, A; Czipin, S; Mittermair, R; Weiss, S; Pratschke, J; Kafka-Ritsch, R

    2016-03-01

    The aim of this study was to investigate the clinical usefulness of the placement of a transanal drainage tube to prevent anastomotic leakage in colorectal anastomoses. This single-center retrospective trial included all patients treated with surgery for benign or malign colorectal disease between January 2009 and December 2012. The transanal drainage tube was immediately placed after colorectal anastomosis until day five and was routinely used since 2010. Patients treated with a transanal drainage tube were compared with the control group. Statistical analysis was performed using Fisher's exact or Chi-square tests for group comparison and a linear regression model for multivariate analysis. This study included 242 patients (46% female; median age 63 years; range 18-93); 34% of the patients underwent a laparoscopic procedure, and 57% of the patients received a placement of a transanal drainage tube. Anastomotic leakage occurred in 19 patients (7.9%). Univariate analysis showed a higher rate of anastomotic leakage in patients with an ASA score 4 (p = 0.02) and a lower rate in patients with transanal drainage placement (3.6% vs. 13.6%; p = 0.007). The grading of the complication of anastomotic leakage was reduced with transanal drainage (e.g., Dindo ≧ 3b: 20.0% vs. 92.9%; p = 0.006), and the hospital stay was shortened (17.6 ± 12.5 vs. 22.1 ± 17.6 days; p = 0.02). Multivariate analysis revealed that transanal drainage was the only significant factor (HR = -2.90; -0.168 to -0.032; p = 0.007) affecting anastomotic leakage. Placement of a transanal drainage tube in patients with colorectal anastomoses is a safe and simple technique to perform and reduces anastomotic leakage, the severity of the complication and hospital stay.

  2. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding

    PubMed Central

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-01-01

    AIM: To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. METHODS: Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. RESULTS: In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. CONCLUSION: The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding. PMID:25009396

  3. Urolume stent placement for the treatment of postbrachytherapy bladder outlet obstruction.

    PubMed

    Konety, B R; Phelan, M W; O'Donnell, W F; Antiles, L; Chancellor, M B

    2000-05-01

    Transurethral resection (TURP) or incision of the prostate is generally not effective for treating bladder outlet obstruction after transperineal brachytherapy for prostate cancer. Furthermore, TURP could compromise full-dose effective radiation delivery to the prostate. We analyzed the efficacy of the UroLume stent in treating the urinary outflow obstruction in such patients. Five patients who had undergone brachytherapy (3 with (192)Ir high-dose radiation and 2 with (125)I) subsequently developed one or more episodes of urinary retention 2 weeks to 4 years after treatment. The patients failed or could not tolerate alpha-blockers or clean intermittent catheterization. Three patients subsequently underwent urethral dilation/optical internal urethrotomy for strictures, and 1 patient underwent suprapubic tube placement. Following the failure of these interventions, each of these patients had a UroLume stent placement. A single UroLume stent (2 cm in 3 patients and 2.5 cm in 2 patients) was placed under local/spinal anesthesia. All patients were able to void spontaneously immediately after stent placement. Of the patients with previous urethral strictures, 1 remained continent and 1 had persistent incontinence. Neither of the patients with early postbrachytherapy retention developed incontinence after stent placement. The main complaints following stent placement were referred pain to the head of the penis and dysuria. Stent-related symptoms necessitated stent removal in 2 of 5 patients, 4 to 6 weeks after placement. The UroLume stent can be used as an alternative form of therapy for managing postbrachytherapy bladder outlet obstruction. The treatment is easily reversible by removing the stent when obstruction resolves.

  4. A novel quick transendoscopic enteral tubing in mid-gut: technique and training with video.

    PubMed

    Long, Chuyan; Yu, Yan; Cui, Bota; Jagessar, Sabreen Abdul Rahman; Zhang, Jie; Ji, Guozhong; Huang, Guangming; Zhang, Faming

    2018-03-13

    This study aimed to evaluate the feasibility, safety, and value of a quick technique for transendoscopic enteral tubing (TET) through mid-gut. A prospective interventional study was performed in a single center. A TET tube was inserted into mid-gut through the nasal orifice and fixed on the pylorus wall by one tiny titanium endoscopic clip under anesthesia. The feasibility, safety, success rate, and satisfaction with TET placement were evaluated for enteral nutrition or fecal microbiota transplantation. A total of 86 patients underwent mid-gut TET. The success rate of the TET procedure was 98.8% (85/86). Mean tubing time of the TET procedure was 4.2 ± 1.9 min. 10 cases of procedure was enough for training of general endoscopist to shorten the procedure time (7.0 min vs 4.0 min, p < 0.05). 97.7% (84/86) of patients were satisfied with the TET placement. Procedure-related and tube-related adverse events were observed in 8.1% (7/86) and 7.0% (6/86) of patients respectively. There were no moderate to severe adverse events during tube extubation. TET through mid-gut is a novel, convenient, reliable and safe procedure for mid-gut administration with a high degree of patient satisfaction. This research was retrospectively registered with clinicaltrials.gov. Trial registration date: 29th November 2017. NCT03335982 .

  5. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    PubMed

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  6. Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.

    PubMed

    Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M

    2017-04-01

    Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Evaluation of chest tube administration of tissue plasminogen activator to treat retained hemothorax.

    PubMed

    Stiles, P J; Drake, Rachel M; Helmer, Stephen D; Bjordahl, Paul M; Haan, James M

    2014-06-01

    When retained hemothorax occurs, video-assisted thoracoscopy or thoracotomy is performed, but recently, tissue plasminogen activator (tPA) has been used. This study evaluated intrapleural tPA use for retained traumatic hemothoraces. A retrospective review was conducted of trauma patients treated with intrapleural tPA for retained hemothorax. Data included demographics, past medical and surgical histories, injury details, treatment details, and outcomes. Seven patients (median age = 47 years, male = 6, blunt trauma = 6) met study criteria. All patients received a chest tube. Six patients later received computed tomography-guided drains for tPA infusion. Number of tPA treatments per patient varied from 1 to 5. Median total tPA dosage was 24 mg. Median time from injury to chest tube placement was 11 days and from chest tube placement to first tPA treatment was 4 days. No patients required a video-assisted thoracoscopy; however, 1 patient required thoracotomy. There were no deaths or bleeding complications attributed to intrapleural tPA. Although future studies are needed to identify optimum treatment guidelines, intrapleural tPA appears to be a safe and efficacious treatment option. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. A comparison of intubation success for paediatric transport team paramedics using lighted vs regular tracheal tube stylets.

    PubMed

    MacNab, A J; MacPhail, I; MacNab, M K; Noble, R; O'Flaherty, D

    1998-01-01

    We conducted a prospective randomized study of success rate and time to intubation using Trachlight and Surch-Lite lighted stylets versus a regular tracheal tube stylet, in a training setting. Participants, 18 paediatric transport paramedics, performed two intubations with each of the three devices, using an airway management trainer. There was no significant difference in mean time for intubation between the three devices. The times for external confirmation of correct tube placement were comparable using the two lighted stylets. External confirmation of the tube placement using the lighted stylets was quicker than laryngoscopic visualization. In darkness, with a nonfunctioning laryngoscope, intubations were successfully performed 100% of the time with the lighted stylet, but only 11% of the time with the regular stylet. All paramedics felt that a lighted stylet would be a useful airway management adjunct for the transport environment for complicated intubations or for use in very high or low levels of ambient light.

  9. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    PubMed

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  10. Mothers' process of decision making for gastrostomy placement.

    PubMed

    Brotherton, Ailsa; Abbott, Janice

    2012-05-01

    In this article we present the findings of an exploration of mothers' discourses on decision making for gastrostomy placement for their child. Exploring in-depth interviews of a purposive sample, we analyzed the mothers' discourses of the decision-making process to understand how their experiences of the process influenced their subsequent constructions of decision making. Mothers negotiated decision making by reflecting on their personal experiences of feeding their child, either orally or via a tube, and interwove their background experiences with the communications from members of the health care team until a decision was reached. Decision making was often fraught with difficulty, resulting in anxiety and guilt. Experiences of decision making ranged from perceived coercion to true choice, which encompasses a truly child-centered decision. The resulting impact of the decision-making process on the mothers was profound. We conclude with an exploration of the implications for clinical practice and describe how health care professionals can support mothers to ensure that decision-making processes for gastrostomy placement in children are significantly improved.

  11. Keyword: Placement

    ERIC Educational Resources Information Center

    Cassuto, Leonard

    2012-01-01

    The practical goal of graduate education is placement of graduates. But what does "placement" mean? Academics use the word without thinking much about it. "Placement" is a great keyword for the graduate-school enterprise. For one thing, its meaning certainly gives a purpose to graduate education. Furthermore, the word is a portal into the way of…

  12. Thoracostomy tubes: A comprehensive review of complications and related topics

    PubMed Central

    Kwiatt, Michael; Tarbox, Abigail; Seamon, Mark J.; Swaroop, Mamta; Cipolla, James; Allen, Charles; Hallenbeck, Stacinoel; Davido, H. Tracy; Lindsey, David E.; Doraiswamy, Vijay A.; Galwankar, Sagar; Tulman, David; Latchana, Nicholas; Papadimos, Thomas J.; Cook, Charles H.; Stawicki, Stanislaw P.

    2014-01-01

    Tube thoracostomy (TT) placement belongs among the most commonly performed procedures. Despite many benefits of TT drainage, potential for significant morbidity and mortality exists. Abdominal or thoracic injury, fistula formation and vascular trauma are among the most serious, but more common complications such as recurrent pneumothorax, insertion site infection and nonfunctioning or malpositioned TT also represent a significant source of morbidity and treatment cost. Awareness of potential complications and familiarity with associated preventive, diagnostic and treatment strategies are fundamental to satisfactory patient outcomes. This review focuses on chest tube complications and related topics, with emphasis on prevention and problem-oriented approaches to diagnosis and treatment. The authors hope that this manuscript will serve as a valuable foundation for those who wish to become adept at the management of chest tubes. PMID:25024942

  13. Comparison between orogastric tube/bougie and a suction calibration system for effects on operative duration, staple-line corkscrewing, and esophageal perforation during laparoscopic sleeve gastrectomy.

    PubMed

    Gagner, Michel; Huang, Rose Y

    2016-04-01

    Placement of a bougie for sleeve sizing during laparoscopic sleeve gastrectomy (LSG) is recommended. We compared this standard with a suction calibration system (SCS) that performs all functions with one insertion, and measured each step's duration. Primary LSG was performed using a bougie and SCS in alternating order. Number of tube movements to achieve optimal placement, durations of decompression, leak testing, and overall operative time, and remnant linear measurements were obtained. LSG was performed in 26 patients (15 women, 11 men; mean age 36.8 years; mean BMI 45.3 kg/m(2)). The mean number of tube movements was significantly greater for the bougie than for the SCS (8.13 vs. 3.58; p < 0.0001). Percent reductions achieved using the SCS were: time to full decompression of the stomach, 62% (21 vs. 8 s; p < 0.138); tube placement, 51% (101 vs. 49 s; p < 0.0001); leak testing, 78% (119 vs. 26 s; p < 0.0003); and mean operative duration (from tube insertion to end of stapling), 21% (875 vs. 697 s; p < 0.019). Variance of the staple-line distance, measured from the greater curvature to the staple line, was 1.64 and 0.92 for the bougie and SCS, respectively, indicating a reduction in corkscrewing, for a 43.9% straighter sleeve. SCS maintained the gastric wall in place, thereby preventing corkscrewing, and reducing total operating time. Reducing the number of tube insertions may prevent esophageal damage and accidental tube stapling.

  14. Risk factors for proximal migration of biliary tube stents

    PubMed Central

    Kawaguchi, Yoshiaki; Ogawa, Masami; Kawashima, Yohei; Mizukami, Hajime; Maruno, Atsuko; Ito, Hiroyuki; Mine, Tetsuya

    2014-01-01

    AIM: To analyze the risk factors for biliary stent migration in patients with benign and malignant strictures. METHODS: Endoscopic stent placement was performed in 396 patients with bile duct stenosis, at our institution, between June 2003 and March 2009. The indications for bile duct stent implantation included common bile duct stone in 190 patients, malignant lesions in 112, chronic pancreatitis in 62, autoimmune pancreatitis in 14, trauma in eight, surgical complications in six, and primary sclerosing cholangitis (PSC) in four. We retrospectively examined the frequency of stent migration, and analyzed the patient factors (disease, whether endoscopic sphincterotomy was performed, location of bile duct stenosis and diameter of the bile duct) and stent characteristics (duration of stent placement, stent type, diameter and length). Moreover, we investigated retrieval methods for migrated stents and their associated success rates. RESULTS: The frequency of tube stent migration in the total patient population was 3.5%. The cases in which tube stent migration occurred included those with common bile duct stones (3/190; 1.6%), malignant lesions (2/112; 1.8%), chronic pancreatitis (4/62; 6.5%), autoimmune pancreatitis (2/14; 14.3%), trauma (1/8; 12.5%), surgical complications (2/6; 33.3%), and PSC (0/4; 0%). The potential risk factors for migration included bile duct stenosis secondary to benign disease such as chronic pancreatitis and autoimmune pancreatitis (P = 0.030); stenosis of the lower bile duct (P = 0.031); bile duct diameter > 10 mm (P = 0.023); duration of stent placement > 1 mo (P = 0.007); use of straight-type stents (P < 0.001); and 10-Fr sized stents (P < 0.001). Retrieval of the migrated stents was successful in all cases. The grasping technique, using a basket or snare, was effective for pig-tailed or thin and straight stents, whereas the guidewire cannulation technique was effective for thick and straight stents. CONCLUSION: Migration of tube stents

  15. Risk factors for proximal migration of biliary tube stents.

    PubMed

    Kawaguchi, Yoshiaki; Ogawa, Masami; Kawashima, Yohei; Mizukami, Hajime; Maruno, Atsuko; Ito, Hiroyuki; Mine, Tetsuya

    2014-02-07

    To analyze the risk factors for biliary stent migration in patients with benign and malignant strictures. Endoscopic stent placement was performed in 396 patients with bile duct stenosis, at our institution, between June 2003 and March 2009. The indications for bile duct stent implantation included common bile duct stone in 190 patients, malignant lesions in 112, chronic pancreatitis in 62, autoimmune pancreatitis in 14, trauma in eight, surgical complications in six, and primary sclerosing cholangitis (PSC) in four. We retrospectively examined the frequency of stent migration, and analyzed the patient factors (disease, whether endoscopic sphincterotomy was performed, location of bile duct stenosis and diameter of the bile duct) and stent characteristics (duration of stent placement, stent type, diameter and length). Moreover, we investigated retrieval methods for migrated stents and their associated success rates. The frequency of tube stent migration in the total patient population was 3.5%. The cases in which tube stent migration occurred included those with common bile duct stones (3/190; 1.6%), malignant lesions (2/112; 1.8%), chronic pancreatitis (4/62; 6.5%), autoimmune pancreatitis (2/14; 14.3%), trauma (1/8; 12.5%), surgical complications (2/6; 33.3%), and PSC (0/4; 0%). The potential risk factors for migration included bile duct stenosis secondary to benign disease such as chronic pancreatitis and autoimmune pancreatitis (P = 0.030); stenosis of the lower bile duct (P = 0.031); bile duct diameter > 10 mm (P = 0.023); duration of stent placement > 1 mo (P = 0.007); use of straight-type stents (P < 0.001); and 10-Fr sized stents (P < 0.001). Retrieval of the migrated stents was successful in all cases. The grasping technique, using a basket or snare, was effective for pig-tailed or thin and straight stents, whereas the guidewire cannulation technique was effective for thick and straight stents. Migration of tube stents within the bile duct is rare but

  16. The Fate of Fat: Pre-Exposure Fat Losses during Nasogastric Tube Feeding in Preterm Newborns

    PubMed Central

    Rayyan, Maissa; Rommel, Nathalie; Allegaert, Karel

    2015-01-01

    Deficient nutritional support and subsequent postnatal growth failure are major covariates of short- and long-term outcome in preterm neonates. Despite its relevance, extrauterine growth restriction (EUGR) is still prevalent, occurring in an important portion of extremely preterm infants. Lipids provide infants with most of their energy needs, but also cover specific supplies critical to growth, development and health. The use of human milk in preterm neonates results in practices, such as milk storage, pasteurization and administration by an infusion system. All of these pre-exposure manipulations significantly affect the final extent of lipid deposition in the intestinal track available for absorption, but the impact of tube feeding is the most significant. Strategies to shift earlier to oral feeding are available, while adaptations of the infusion systems (inversion, variable flow) have only more recently been shown to be effective in “in vitro”, but not yet in “in vivo” settings. Pre-exposure-related issues for drugs and nutritional compounds show similarities. Therefore, we suggest that the available practices for “in vitro” drug evaluations should also be considered in feeding strategies to further reduce pre-exposure losses as a strategy to improve the nutritional status and outcome of preterm neonates. PMID:26230707

  17. Occult pneumothorax in the blunt trauma patient: tube thoracostomy or observation?

    PubMed

    Wilson, Heather; Ellsmere, James; Tallon, John; Kirkpatrick, Andrew

    2009-09-01

    The term occult pneumothorax (OP) describes a pneumothorax that is not suspected on the basis of either clinical examination or initial chest radiography, but is subsequently detected on computed tomography (CT) scan. The optimal management of OP in the blunt trauma setting remains controversial. Some physicians favour placement of a thoracostomy tube for patients with OP, particularly those undergoing positive pressure ventilation (PPV), while others favour close observation without chest drainage. This study was conducted both to determine the incidence of OP and to describe its current treatment status in the blunt trauma population at a Canadian tertiary trauma centre. Of interest were the rates of tube thoracostomy vs. observation without chest drainage and their respective outcomes. A retrospective review was conducted of the Nova Scotia Trauma Registry. The data on all consecutive blunt trauma patients between October 1994 and March 2003 was reviewed. Outcome measures evaluated include length of stay, discharge status-dead vs. alive, intervention and time to intervention (tube thoracostomy and its relation to institution of PPV). Direct comparison was made between the OP with tube thoracostomy group and OP without tube thoracostomy group (observation or control group). They were compared in terms of their baseline characteristics and outcome measures. In 1881 consecutive blunt trauma patients over a 102-month period there were 307 pneumothoraces of which 68 were occult. Thirty five patients with OP underwent tube thoracostomy, 33 did not. Twenty nine (82.8%) with tube thoracostomy received positive pressure ventilation (PPV), as did 16 (48.4%) in the observation group. Mean injury severity score (ISS) for tube thoracostomy and observation groups were similar (25.80 and 22.39, p=0.101) whereas length of stay (LOS) was different (17.4 and 10.0 days, p=0.026). Mortality was similar (11.4% and 9.1%). There were no tension pneumothoraces. The natural history of

  18. Eustachian Tube Dilation via a Transtympanic Approach in 6 Cadaver Heads: A Feasibility Study.

    PubMed

    Dean, Marc; Chao, Wei-Chieh; Poe, Dennis

    2016-10-01

    The goal of this study was to evaluate the feasibility of endoscopic transtympanic balloon dilation of the cartilaginous eustachian tube. To accomplish this, transtympanic balloon dilation of the cartilaginous eustachian tube was performed on 11 eustachian tubes (6 cadaver heads). The balloon catheter was introduced and passed through the protympanic orifice of the eustachian tube transtympanically under endoscopic view and cannulated without incident in all cadavers. Computed tomography was then performed postprocedure to evaluate for inadvertent dilation of the bony eustachian tube, adverse placement of the balloon, or any bony fractures. The balloon was seen to be successfully inflated in the cartilaginous portion without damage to surrounding structures in all cases. This demonstrates that under endoscopic guidance, the protympanic orifice of the eustachian tube can be feasibly cannulated and reliably traversed, allowing for targeted dilation of the cartilaginous eustachian tube from a transtympanic approach. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  19. What is the full range of medical and surgical treatments available for patients with Eustachian tube dysfunction?

    PubMed

    Adil, Eelam; Poe, Dennis

    2014-02-01

    To present the current medical and surgical treatment options for Eustachian tube dysfunction. Balloon dilation or microdebrider Eustachian tuboplasty are feasible treatment options for patients with refractory dilatory dysfunction as an alternative to tympanostomy tube placement. There is increasing evidence that repair of patulous Eustachian tubes by the insertion of a shim or fat graft reconstruction within the lumen of the Eustachian tube orifice may be effective. In patients with Eustachian tube dysfunction that is refractory to medical management, newer surgical techniques may provide symptomatic relief with a reasonable duration. Continued basic science research into the cause of dysfunction, the mechanisms of benefit from intervention and long-term clinical outcomes are necessary.

  20. Intra-cavitary dosimetry for IMRT head and neck treatment using thermoluminescent dosimeters in a naso-oesophageal tube.

    PubMed

    Gagliardi, F M; Roxby, K J; Engström, P E; Crosbie, J C

    2009-06-21

    Complex intensity-modulated radiation therapy (IMRT) treatment plans require rigorous quality assurance tests. The aim of this study was to independently verify the delivered dose inside the patient in the region of the treatment site. A flexible naso-gastric tube containing thermoluminescent dosimeters (TLDs) was inserted into the oesophagus via the sinus cavity before the patient's first treatment. Lead markers were also inserted into the tube in order that the TLD positions could be accurately determined from the lateral and anterior-posterior electronic portal images taken prior to treatment. The measured dose was corrected for both daily linac output variations and the estimated dose received from the portal images. The predicted dose for each TLD was determined from the treatment planning system and compared to the measured TLD doses. The results comprise 431 TLD measurements on 43 patients. The mean measured-to-predicted dose ratio was 0.988 +/- 0.011 (95% confidence interval) for measured doses above 0.2 Gy. There was a variation in this ratio when the measurements were separated into low dose (0.2-1.0 Gy), medium dose (1.0-1.8 Gy) and high dose (>1.8 Gy) measurements. The TLD-loaded, naso-oesophageal tube for in vivo dose verification is straightforward to implement, and well tolerated by patients. It provides independent reassurance of the delivered dose for head and neck IMRT.

  1. Intra-cavitary dosimetry for IMRT head and neck treatment using thermoluminescent dosimeters in a naso-oesophageal tube

    NASA Astrophysics Data System (ADS)

    Gagliardi, F. M.; Roxby, K. J.; Engström, P. E.; Crosbie, J. C.

    2009-06-01

    Complex intensity-modulated radiation therapy (IMRT) treatment plans require rigorous quality assurance tests. The aim of this study was to independently verify the delivered dose inside the patient in the region of the treatment site. A flexible naso-gastric tube containing thermoluminescent dosimeters (TLDs) was inserted into the oesophagus via the sinus cavity before the patient's first treatment. Lead markers were also inserted into the tube in order that the TLD positions could be accurately determined from the lateral and anterior-posterior electronic portal images taken prior to treatment. The measured dose was corrected for both daily linac output variations and the estimated dose received from the portal images. The predicted dose for each TLD was determined from the treatment planning system and compared to the measured TLD doses. The results comprise 431 TLD measurements on 43 patients. The mean measured-to-predicted dose ratio was 0.988 ± 0.011 (95% confidence interval) for measured doses above 0.2 Gy. There was a variation in this ratio when the measurements were separated into low dose (0.2-1.0 Gy), medium dose (1.0-1.8 Gy) and high dose (>1.8 Gy) measurements. The TLD-loaded, naso-oesophageal tube for in vivo dose verification is straightforward to implement, and well tolerated by patients. It provides independent reassurance of the delivered dose for head and neck IMRT.

  2. Use of intranasal fentanyl in children undergoing myringotomy and tube placement during halothane and sevoflurane anesthesia.

    PubMed

    Galinkin, J L; Fazi, L M; Cuy, R M; Chiavacci, R M; Kurth, C D; Shah, U K; Jacobs, I N; Watcha, M F

    2000-12-01

    Many children are restless, disoriented, and inconsolable immediately after bilateral myringotomy and tympanosotomy tube placement (BMT). Rapid emergence from sevoflurane anesthesia and postoperative pain may increase emergence agitation. The authors first determined serum fentanyl concentrations in a two-phase study of intranasal fentanyl. The second phase was a prospective, placebo-controlled, double-blind study to determine the efficacy of intranasal fentanyl in reducing emergence agitation after sevoflurane or halothane anesthesia. In phase 1, 26 children with American Society of Anesthesiologists (ASA) physical status I or II who were scheduled for BMT received intranasal fentanyl, 2 microg/kg, during a standardized anesthetic. Serum fentanyl concentrations in blood samples drawn at emergence and at postanesthesia care unit (PACU) discharge were determined by radioimmunoassay. In phase 2, 265 children with ASA physical status I or II were randomized to receive sevoflurane or halothane anesthesia along with either intranasal fentanyl (2 microg/kg) or saline. Postoperative agitation, Children's Hospital of Eastern Ontario Pain Scale (CHEOPS) scores, and satisfaction of PACU nurses and parents with the anesthetic technique were evaluated. In phase 1, the mean fentanyl concentrations at 10 +/- 4 min (mean +/- SD) and 34 +/- 9 min after administering intranasal fentanyl were 0.80 +/- 0.28 and 0.64 +/- 0.25 ng/ml, respectively. In phase 2, the incidence of severe agitation, highest CHEOPS scores, and heart rate in the PACU were decreased with intranasal fentanyl. There were no differences between sevoflurane and halothane in these measures and in times to hospital discharge. The incidence of postoperative vomiting, hypoxemia, and slow respiratory rates were not increased with fentanyl. Serum fentanyl concentrations after intranasal administration exceed the minimum effective steady state concentration for analgesia in adults. The use of intranasal fentanyl during

  3. Nasogastric feeding at the end of life: a virtue ethics approach.

    PubMed

    Krishna, Lalit

    2011-07-01

    The use of Nasogastric (NG) feeding in the provision of artificial nutrition and hydration at the end of life has, for the most part, been regarded as futile by the medical community. This position has been led chiefly by prevailing medical data. In Singapore, however, there has been an increase in its utilization supported primarily by social, religious and cultural factors expressly to prolong life of the terminally ill patient. Here this article will seek to review the ethical and clinical impact of this treatment and provide some understanding for such decisions in the light of the Duty of Palliative Care [DoPC]. Complemented by virtue ethics theory, the DoPC highlights and seeks to realize the individual case specific goals of care that maximize comfort and quality of life of the patient in the face of rapid attenuation of treatment options and the eminence of the final outcome by considering each of these factors individually in order to provide the best outcome for the patient and the family.

  4. Clinical use of low-profile cystostomy tubes in four dogs and a cat.

    PubMed

    Stiffler, Kevin S; McCrackin Stevenson, M A; Cornell, Karen K; Glerum, Leigh E; Smith, Julie D; Miller, Nathan A; Rawlings, Clarence A

    2003-08-01

    Traditional cystostomy tubes (used for temporary or permanent diversion of urine in dogs and cats) are long (> or = 22 cm) and cumbersome to stabilize, requiring sutures or bandages to hold the tube against the body. Use of a low-profile gastrostomy port system as a low-profile cystostomy tube (LPCT) in 4 dogs and a cat was investigated; owner satisfaction with the device was assessed. Technical difficulty associated with placement and management of LPCTs was similar to that for traditional cystostomy tubes; with LPCTs, activity and mobility of pets was not compromised, and bandaging was not required. Complications included lower urinary tract infection, mild peristomal leakage of urine and leakage from components of the system, and subcutaneous peristomal infection. Four of 5 owners considered the tube to be easy to use; all owners said they would be comfortable repeating their decision to use the LPCT in their pet.

  5. A Meta-Analysis of Bilateral Essure® Procedural Placement Success Rates on First Attempt

    PubMed Central

    Frietze, Gabriel; Rahman, Mahbubur; Rouhani, Mahta; Berenson, Abbey B.

    2015-01-01

    Abstract Background: The Essure® (Bayer HealthCare Pharmaceuticals, Leverkusen, Germany) female sterilization procedure entails using a hysteroscope to guide a microinsert into the Fallopian tube openings. Failed placement can lead to patient dissatisfaction, repeat procedures, unintended or ectopic pregnancy, perforation of internal organs, or need for subsequent medical interventions. Additional interventions increase women's health risks, and costs for patients and the health care industry. Demonstrated successful placement rates are 63%–100%. To date, there have not been any systematic analyses of variables associated with placement rates. Objectives: The aims of this review were: (1) to estimate the average rate of successful bilateral Essure microinsert placement on first attempt; and (2) to identify variables associated with successful placement. Materials and Methods: A meta-analysis was conducted on 64 published studies and 19 variables. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, all published studies between November 2001 and February 2015 were reviewed. The studies were taken from from PubMed and Google Scholar, and by using the the “snowball” method that reported variables associated with successful bilateral Essure placement rates. Results: The weighted average rate of successful bilateral microinsert placement on first attempt was 92% (0.92 [95% confidence interval: 0.904–0.931]). Variables associated with successful placements were: (1) newer device models; (2) higher body mass index; and (3) a higher percent of patients who received local anesthesia. Conclusions: The data gathered for this review indicate that the highest bilateral success rates may be obtained by utilizing the newest Essure device model with local anesthesia in heavier patients. More standardized data reporting in published Essure studies is recommended. (J GYNECOL SURG 31:308) PMID:26633935

  6. [Successful treatment of locally advanced squamous cell carcinoma of the esophagus by combination chemotherapy with 5-fluorouracil plus nedaplatin following tracheal stent tube placement-a case report].

    PubMed

    Nishimura, Junya; Kubo, Naoshi; Lee, Tomohiro; Shinto, Osamu; Sakurai, Katsunobu; Toyokawa, Takahiro; Tanaka, Hiroaki; Muguruma, Kazuya; Shibutani, Masatsune; Yamazoe, Sadaaki; Nagahara, Hisashi; Kimura, Kenjiro; Amano, Ryosuke; Ohtani, Hiroshi; Yashiro, Masakazu; Maeda, Kiyoshi; Ohira, Masaichi; Hirakawa, Kosei

    2013-11-01

    The patient was a 68-year-old man who complained of hoarseness and dyspnea. Upper gastrointestinal endoscopy revealed a type 3 tumor located in the middle thoracic esophagus at 30 cm from the incisor tooth that involved one-fourth of the circumference of the esophagus. Histopathological examination revealed moderately differentiated squamous cell carcinoma. Chest computed tomography( CT) revealed severe tracheal stenosis due to compression by a metastatic lymph node along the left recurrent laryngeal nerve. The patient was diagnosed as having cT4( 106recL-trachea), N2( 101L, 106recL, 106recR), M0, Stage IVa unresectable esophageal carcinoma. After insertion of a tracheal stent tube( spiral Z stent: diameter, 18 mm; length, 80 mm) to improve dyspnea, combination chemotherapy with 5-fluorouracil( 5-FU) plus nedaplatin was administered. Subsequent CT and endoscopy showed that the main tumor and the metastatic lymph node had significantly reduced in size and that complete response (CR) had been achieved. Thirty months after the initial treatment, the patient showed no sign of disease recurrence, after completion of 19 cycles of chemotherapy. The patient did not experience any severe adverse events. We report a case of a patient with locally advanced squamous cell carcinoma of the esophagus successfully treated with 5-FU/nedaplatin combination chemotherapy following tracheal stent tube placement.

  7. T-tube drainage of the common bile duct choleperitoneum: etiology and management.

    PubMed

    Daldoul, S; Moussi, A; Zaouche, A

    2012-06-01

    External drainage of the common bile duct by placement of a T-tube is a common practice after choledochotomy. This practice may result in the specific complication of bile peritonitis due to leakage after removal of the T-tube. This complication has multiple causes: some are patient-related (corticotherapy, chemotherapy, ascites), and others are due to technical factors (inappropriate suturing of the drain to the ductal wall, minimal inflammatory reaction related to some drain materials). The clinical presentation is quite variable depending on the amount and rapidity of intra-peritoneal spread of of bile leakage. Abdominal ultrasound (US), with US-guided needle aspiration and occasionally Technetium(99) scintigraphy are useful for diagnosis. Traditional therapy consists of surgical intervention including peritoneal lavage and re-intubation of the choledochal fistulous tract to allow for a further period of external drainage. When leakage is walled off and well-tolerated, a more nuanced and less invasive conservative therapy may combine percutaneous drainage with endoscopic placement of a trans-ampullary biliary drainage. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  8. Rare finding of Eustachian tube calcifications with cone-beam computed tomography.

    PubMed

    Syed, Ali Z; Hawkins, Anna; Alluri, Leela Subashini; Jadallah, Buthainah; Shahid, Kiran; Landers, Michael; Assaf, Hussein M

    2017-12-01

    Soft tissue calcification is a pathological condition in which calcium and phosphate salts are deposited in the soft tissue organic matrix. This study presents an unusual calcification noted in the cartilaginous portion of the Eustachian tube. A 67-year-old woman presented for dental treatment, specifically for implant placement, and cone-beam computed tomography (CBCT) was performed. The CBCT scan was reviewed by a board-certified oral and maxillofacial radiologist and revealed incidental findings of 2 distinct calcifications in the cartilaginous portion of the Eustachian tube. To the authors' knowledge, no previous study has reported the diagnosis of Eustachian tube calcification using CBCT. This report describes an uncommon variant of Eustachian tube calcification, which has a significant didactic value because such cases are seldom illustrated either in textbooks or in the literature. This case once again underscores the importance of having CBCT scans evaluated by a board-certified oral and maxillofacial radiologist.

  9. Nutrition accesses among patients receiving enteral treatment in the home environment.

    PubMed

    Sznajder, Janusz; Ślefarska-Wasilewska, Marta; Wójcik, Piotr

    2017-10-31

    Enteral feeding in the home environment is connected with creating access to digestive tract, and thanks to that, this kind of treatment is possible. The gold standard in enteral nutrition is PEG, other types of access are: nasogastric tube, gastronomy and jejunostomy. In the article 851 patients who were treated nutritionally in the home environment, in the nutrition clinic, Nutrimed Górny Śląsk, were analyzed. It was described how, in practice, the schedule of nutrition access looks like in the nutrition clinic at a time of qualifying patients to the treatment (PEG 47,35%, gastronomy 18,91%, nasogastric tube 17,39%,jejunostomy 16,33%) and how it changes among patients treated in the nutrition clinic during specific period of time - to the treatment there were qualified patients with at least three-month period of therapy ( second evaluation: PEG 37,01%, gastrostomy 31,13%, nasogastric tube 16,98%, jejunostomy 15,86%). The structure of changes was described, also the routine and the place in what exchanging or changing nutrition access was analyzed. The biggest changes in quantity, among all groups of ill people concerned patients with PEG and gastronomy. In most cases the intervention connected with exchanging access to the digestive tract could be implemented at patient's home.

  10. [Hysteroscopic fallopian tube sterilization procedure: feasibility and one-year follow-up].

    PubMed

    Gibon, E; Lopès, P; Linet, T; Martigny, H; Orieux, C; Philippe, H-J

    2006-03-01

    Hysteroscopic flexible micro-insert (Essure) is an ambulatory improvement of fallopian tube sterilization, which is a deliberated suppression of fertility. The aim of this study was an evaluation of feasibility (learning curve) and the first year outcome of this method. This prospective study, carried out between February 2002 and March 2003, included patients who were matching with manufacturer recommendations. One surgeon only realized all the device placements. Fifty patients were included (one year follow-up). Mean age was 41 (+/-3.3), mean parity was 2.7 (+/-0.8). Mean time needed for device placement was 26 minutes (+/-6.5) and was reduced with increased experience. Six failures of placement (12%) were related, because of submucus leiomyomas, proximal tubal stenotic disease or too retroverted uterus. Only 5 patients (11,4%) described intensive pelvic pain during the placement. The only case of device expulsion benefited from a successful second placement. The one-year follow-up showed no significant difference of body weight increasing, duration or quantity of menstruation, neither significant pelvic pain nor vaginal bleeding. Tolerance was rated at least at "somewhat satisfied". There have been no pregnancies reported in 670 woman-months of effectiveness. Our results agree in any point with those of larger studies. We think that hysteroscopy micro-insert placement is not only reserved to specialized centers but also to any gynecologist who is used to performing hysteroscopy because of its feasibility.

  11. [MRI of aortic arch anomalies in children. Initial results].

    PubMed

    Mamou Mani, T; Lallemand, D; Brunelle, F; Barth, M O

    1988-12-01

    A prospective study by nuclear magnetic resonance in 7 infants with respiratory disorders and with a barium swallow suggestive of anomalies of the aortic arch was conducted. It allowed the definition of an investigation protocol including sedation, RF coil adapted to infants size, naso-gastric tube placement, thin MR sections. Sequences are T1 weighted with ECG gating in two perpendicular frontal oblique and transverse oblique planes determined on a scout sagittal MR acquisition. Precise determination of the anatomy of the vascular malformation and its relationship with the trachea and esophagus were obtained. After definition of the investigation protocol, MRI was found to be a very effective evaluation technique for aortic arch anomalies. It can be proposed as an alternative to preoperative digital angiography. Its indications remain to be defined in relation to the clinical features and the results of the chest X-ray and barium swallow.

  12. Familial link of otitis media requiring tympanostomy tubes.

    PubMed

    Padia, Reema; Alt, Jeremiah A; Curtin, Karen; Muntz, Harlan R; Orlandi, Richard R; Berger, Justin; Meier, Jeremy D

    2017-04-01

    Placement of tympanostomy tubes for recurrent or chronic otitis media is the most commonly performed ambulatory procedure in the United States. Etiologies have been speculated to be environmentally based, and studies have suggested a genetic component to the disease. However, no large-scale studies have attempted to define a familial component. The objective of this study was to determine the familial risk of otitis media requiring tympanostomy tubes (OMwTT) in a statewide population. Retrospective observational cohort study with population-based matched controls. Using an extensive genealogical database linked to medical records, the familial risk of OMwTT was calculated for relatives of probands (46,249 patients diagnosed with OMwTT from 1996-2013) compared to random population controls matched 5:1 on sex and birth year from logistic regression models. The median age at time of tympanostomy tube placement was 1 year (interquartile range, 0-2 years). First-degree relatives of patients with OMwTT, primarily siblings, had a 5-fold increased risk of OMwTT (P < 10 -16 ). Second-degree relatives were at a 1.5-fold increased risk (P < 10 -15 ). More extended relatives (third, fourth and fifth degree) showed a 1.4-fold increased risk (P < 10 -15 ). In the largest population-based study to date, a significant familial risk is confirmed in OMwTT, suggesting otitis media may have a significant genetic component given the increased risk found in close as well as distant relatives. This could be influenced by shared environments given a five-times risk observed in siblings. Further understanding the genetic basis of OMwTT and its interplay with environmental factors may clarify the etiology and lead to better detection of disease and treatments. 3b. Laryngoscope, 127:962-966, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Economic evaluation of nasogastric versus intravenous hydration in infants with bronchiolitis.

    PubMed

    Oakley, Ed; Carter, Rob; Murphy, Bridie; Borland, Meredith; Neutze, Jocelyn; Acworth, Jason; Krieser, David; Dalziel, Stuart; Davidson, Andrew; Donath, Susan; Jachno, Kim; South, Mike; Babl, Franz E

    2017-06-01

    Bronchiolitis is the most common lower respiratory tract infection in infants and the leading cause of hospitalisation. We aimed to assess whether intravenous hydration (IVH) was more cost-effective than nasogastric hydration (NGH) as a planned secondary economic analysis of a randomised trial involving 759 infants (aged 2-12 months) admitted to hospital with a clinical diagnosis of bronchiolitis and requiring non-oral hydration. No Australian cost data exist to aid clinicians in decision-making around interventions in bronchiolitis. Cost data collections included hospital and intervention-specific costs. The economic analysis was reduced to a cost-minimisation study, focusing on intervention-specific costs of IVH versus NGH, as length of stay was equal between groups. All analyses are reported as intention to treat. Intervention costs were greater for IVH than NGH ($113 vs $74; cost difference of $39 per child). The intervention-specific cost advantage to NGH was robust to inter-site variation in unit prices and treatment activity. Intervention-specific costs account for <10% of total costs of bronchiolitis admissions, with NGH having a small cost saving across all sites. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  14. Pathogenesis and Treatment of Cerebral Air Embolism and Associated Disorders.

    DTIC Science & Technology

    1984-04-01

    blades) 12. 7.0, 8.0 and 9.0-mm endotracheal tubes 13. Endotracheal tube stylet 14. Esophageal obturator airway 15. Tracheal suction catheters (14F) 17 r...16. Nasogastric suction tube and Tumee syringe 17. Tincture of Benzoin 18. 2-in waterproof tape 19. Precordial stethoscope 20. Esophageal stethoscope...be justified. If an endotracheal tube cannot be passed, an esophageal obturator airway may be useful. If such an airway Is used, the newer models

  15. Pre-radiotherapy feeding tube identifies a poor prognostic subset of postoperative p16 positive oropharyngeal carcinoma patients.

    PubMed

    Verma, Vivek; Liu, Jingxia; Eschen, Laura; Danieley, Jonathan; Spencer, Christopher; Lewis, James S; Diaz, Jason; Piccirillo, Jay F; Adkins, Douglas R; Nussenbaum, Brian; Thorstad, Wade L; Gay, Hiram A

    2015-01-09

    This study explores variables associated with poor prognosis in postoperative p16 positive oropharyngeal squamous cell carcinoma (OPSCC) patients undergoing adjuvant radiotherapy or chemoradiotherapy. Specifically, analysis was done related to timing of feeding tube insertion relative to radiotherapy. From 1997-2009, of 376 consecutive patients with OPSCC, 220 received adjuvant IMRT, and 97 were p16 positive and eligible. Of these, 23 had feeding tube placement before IMRT (B-FT), 32 during/after IMRT (DA-FT), and 42 had no feeding tube (NO-FT). Feeding tubes were not placed prophylactically. These three groups were analyzed for differential tumor, patient, treatment, and feeding tube characteristics, as well as differences in overall survival (OS), disease free survival (DFS), and distant metastasis free survival (DMFS). Pre-RT FT insertion was associated with higher tumor size and depth, T (but not N) and overall stage, comorbidities, presence of chemotherapy, and less use of transoral laser microsurgery/transoral bovie. Additionally, time from surgery to IMRT completion was also statistically longer in the B-FT group. The feeding tube was permanent in 52% of patients in the B-FT group versus 16% in the DA-FT group (p = 0.0075). The 5-year OS for the NO-FT, DA-FT, and B-FT groups was 90%, 86%, and 50%, respectively. The 5-year DFS for the NO-FT, DA-FT, and B-FT groups was 87.6%, 83.6%, and 42.7%, respectively. Multivariate analysis showed that for OS and DFS, feeding tube placement timing and smoking history were statistically significant. Due to the poor prognosis of early FT insertion, the presence of FTs at time of radiotherapy consultation can be used as an alternate marker to identify a subset of p16 positive OPSCC patients that have a poor prognosis.

  16. A case of upside-down stomach that was effectively treated by postprandial repositioning.

    PubMed

    Ono, Kazumasa; Hasegawa, Hiroshi; Obara, Toshimasa; Miyagishima, Kei; Inoue, Shinichiro; Kozaki, Koichi

    2017-01-01

    An 88-year-old woman with a history of stomach perforation and lumbar compression fracture was admitted to our hospital with a chief complaint of continuous vomiting, which she had experienced since the previous day. She showed vomiting, spontaneous pain and tenderness from the epigastric fossa through the left flank. In addition, she had marked kyphosis. On a CT scan, although the fornix was located in the abdominal cavity, the antrum and body had escaped into the thoracic cavity. A large volume of gastric content was observed. The patient was diagnosed with upside-down stomach from gastric volvulus and a hiatal hernia. Although we recommended surgery, the patient and her family did not agree with it. Thus, conservative therapy was selected. The patient's symptoms showed a significant improvement after the placement of a nasogastric tube, fasting and fluid therapy. After stabilization, an endoscopic examination was performed. The release of the gastric volvulus was confirmed and the nasogastric tube was removed. We instructed the patient to perform postprandial repositioning, which was based on the running shape of the digestive tract with the goal of achieving the passage of food and preventing a relapse of vomiting. The patient was instructed to first place herself in the right lateral decubitus position and then the prone position after eating. There was no recurrence of vomiting after the patient resumed eating. She was therefore discharged from our hospital. Upside-down stomach is usually an indication for surgery. However, in elderly patients, the fixation of the stomach to the abdominal wall has been reported to occur after endoscopic reduction, and conservative treatment was thus selected in this case.We herein reported a case in which postprandial repositioning was used to treat upside-down stomach.

  17. "On-command" dissolvable tympanostomy tube in the chinchilla model: A proof of concept.

    PubMed

    Wiedermann, Joshua P; Mai, Johnny P; Dumont, Matthieu; Jenkins, Audrey; Cleary, Kevin; Reilly, Brian K

    2017-10-01

    To prove the concept that a dissolvable "on-command" tympanostomy tube placed into the tympanic membrane of a chinchilla can dissolve when a benign solution is applied and result in a well healed tympanic membrane without histologic evidence of injury. Prospective Randomized Single-Subject Controlled Trial. Prototype tympanostomy tubes were fabricated from poly(butyl methacrylate-co-(2-dimethylaminoethyl) methacrylate-co- methyl methacrylate) (PBM). "In vitro" dissolution studies were performed with applications of the benign chemical, hydrogen peroxide (HP). PBM tubes were placed into ten chinchilla tympanic membranes matched with standard plastic tubes placed into the contralateral side. All 20 tubes were exposed to HP for 21 days with serial endoscopic examinations. In vitro PBM tubes were weighed before and after interventions and compared to control tubes. In vivo photo documentation was used to show progression of dissolution and histologic slides were obtained to show the effect of the PBM on surrounding tissues. Compared to control tubes, all those exposed to hydrogen peroxide had a statistically significant reduction in weight (p < 0.01). After placement into the tympanic membrane of chinchillas, all PBM tubes dissolved within 21 days of hydrogen peroxide treatment leaving behind histologically normal, intact tympanic membranes. Our PBM tubes dissolve "on-command" in a chinchilla model when exposed to treatment with a benign chemical. Dissolvable "on-command" tympanostomy tubes may reduce significant complications related to pediatric tympanostomy tube use. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. [A Case of Removable Self-Expandable Metallic Stent(SEMS)Placement for Gastric Tube Stenosis after Esophageal Cancer Resection].

    PubMed

    Yoshikawa, Yukihiro; Yoshikawa, Masato; Kawabata, Ryohei; Yoshida, Yuta; Kawada, Masahiro; Yasuyama, Akinobu; Watase, Chikashi; Koga, Chikato; Hitora, Toshiki; Murakami, Masahiro; Hirota, Masaki; Ikenaga, Masakazu; Shimizu, Junzo; Hasegawa, Junichi

    2015-11-01

    A 68-year-old man underwent esophagectomy for early esophageal cancer. Postoperative upper gastrointestinal series and esophagogastroduodenoscopy showed gastric tube stenosis. To improve passage, a removable self-expandable metallic stent (SEMS) was placed across the stenotic lesion. Two weeks later, the stent was removed, and passage through the gastric tube improved. The patient has no symptoms of stenosis. A removable SEMS could be an option for the treatment of gastric tube stenosis after esophagectomy.

  19. [Changes in the distance between carina and orotracheal tube during open or videolaparoscopic bariatric surgery].

    PubMed

    de Figueiredo Locks, Giovani; Simões de Almeida, Maria Cristina; Sperotto Ceccon, Maurício; Campos Pastório, Karen Adriana

    2015-01-01

    To examine whether there are changes in the distance between the orotracheal tubeand carina induced by orthostatic retractor placement or by pneumoperitoneum insufflation in obese patients undergoing gastroplasty. 60 patients undergoing bariatric surgery by two techniques: open (G1) or videola-paroscopic (G2) gastroplasty were studied. After tracheal intubation, adequate ventilation of both hemitoraxes was confirmed by lung auscultation. The distance orotracheal tube-carina was estimated with the use of a fiber bronchoscope before and after installation of orthostatic retractors in G1 or before and after insufflation of pneumoperitoneum in patients in G2. G1 was composed of 22 and G2 of 38 patients. No cases of endobronchial intubationwere detected in either group. The mean orotracheal tube-carina distance variation was estimated in -0.03 cm (95% CI 0.06 to -0.13) in the group of patients undergoing open gastroplastyand in -0.42 cm (95% CI -0.56 to -1.4) in the group of patients undergoing videolaparoscopic gastroplasty. The extremes of variation in each group were: 0.5 cm to -1.6 cm in patients under-going open surgery and 0.1 cm to -2.2 cm in patients undergoing videolaparoscopic surgery. There was no significant change in orotracheal tube-CA distance after placementof orthostatic retractors in patients undergoing open gastroplasty. There was a reduction inorotracheal tube-CA distance after insufflation of pneumoperitoneum in patients undergoing videolaparoscopic gastroplasty. We recommend attention to lung auscultation and to signals of ventilation monitoring and reevaluation of orotracheal tube placement after peritoneal insufflation. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. True incidence and clinical significance of pneumoperitoneum after PEG placement: a prospective study.

    PubMed

    Wiesen, Ari J; Sideridis, Kostas; Fernandes, Angelo; Hines, Jonathan; Indaram, Anant; Weinstein, Lenny; Davidoff, Samuel; Bank, Simmy

    2006-12-01

    PEG is a widely used method for providing nutritional support. Although pneumoperitoneum is a known finding after PEG placement, its true incidence is subject to debate. Small retrospective studies have found varied rates of free air after PEG placement. There were a total of 65 patients. To assess the true incidence of pneumoperitoneum and its clinical significance. Prospective study. Long Island Jewish Medical Center. We obtained upright and anterior-posterior chest radiographs of 65 patients within 3 hours after PEG placement. Type of PEG tube, gauge of the needle used, number of sticks, and indications were recorded. The presence of pneumoperitoneum on the initial chest film was considered to be a positive finding. After a positive result, a repeat chest film was obtained 72 hours later to determine whether there was progression or resolution of the free air. Patients enrolled in the study were also monitored clinically for evidence of peritonitis. Of the 65 patients who underwent PEG placement, 13 developed a pneumoperitoneum on the initial chest radiograph; there was complete resolution of pneumoperitoneum at 72 hours in 10 of the 13 patients. In 3 patients, the free air persisted but was of no clinical significance. The free air was quantified by measuring the height of the air column under the diaphragm and was graded with a scoring system (0, no air; 1, small; 2, moderate; 3, large). Eleven patients who underwent PEG died during the hospitalization; none of the deaths were related to the PEG placement or pneumoperitoneum. The other 54 patients were discharged to a skilled nursing facility. No patients in the study had clinical evidence of peritonitis. There were no adverse events, ie, infection or bleeding, associated with the PEG placement in any of the patients. Our data suggest that pneumoperitoneum after PEG placement is common and, in the absence of clinical symptoms, is of no clinical significance and does not warrant any further intervention.

  1. Effect of saline 0.9% or Plasma-Lyte 148 therapy on feeding intolerance in patients receiving nasogastric enteral nutrition.

    PubMed

    Reddy, Sumeet; Bailey, Michael; Beasley, Richard; Bellomo, Rinaldo; Mackle, Diane; Psirides, Alex; Young, Paul

    2016-09-01

    To compare the effect of Plasma-Lyte (PL)-148 and saline 0.9% (saline) on gastrointestinal (GI) feeding intolerance in mechanically ventilated patients receiving nasogastric (NG) feeding in an intensive care unit. A single-centre pilot study, nested within a multicentre, double-blind, cluster-randomised, double-crossover trial, performed in a mixed medical and surgical ICU. All adult patients who required crystalloid fluid therapy as part of the 0.9% Saline versus Plasma-Lyte 148 for Intensive Care Unit Fluid Therapy (SPLIT) trial, were expected to need mechanical ventilation for more than 48 hours and were receiving enteral nutrition exclusively by NG tube were eligible. We enrolled 69 patients and assigned 35 to PL-148 and 34 to saline. We randomly allocated saline or PL-148 for four alternating 7-week blocks, with staff blinded to the solution. The primary outcome was the proportion of patients with GI feeding intolerance, defined as high gastric residual volume (GRV), diarrhoea or vomiting while receiving NG feeding in the ICU. The proportions of patients with each of high GRV, diarrhoea and vomiting were secondary outcomes. In the PL-148 group, 21 of 35 patients (60.0%) developed GI feeding intolerance, compared with 22 of 34 patients (64.7%) in the saline group (odds ratio [OR], 0.82; 95% CI, 0.31-2.17; P = 0.69). A high GRV was seen in four of 35 patients (11.4%) in the PL-148 group, and in 11 of 34 patients (32.4%) in the saline group (OR, 0.27; 95% CI, 0.08-0.96; P = 0.04). Among mechanically ventilated patients receiving NG feeding, the use of PL-148, compared with saline, did not reduce the proportion of patients developing GI feeding intolerance, but was associated with a decreased incidence of high GRV.

  2. Use of proton pump inhibitors is associated with increased mortality due to nosocomial pneumonia in bedridden patients receiving tube feeding.

    PubMed

    Hamai, Kosuke; Iwamoto, Hiroshi; Ohshimo, Shinichiro; Wakabayashi, Yu; Ihara, Daisuke; Fujitaka, Kazunori; Hamada, Hironobu; Ono, Koichi; Hattori, Noboru

    2018-05-22

    To investigate the association between the use of proton pump inhibitors (PPI) and nosocomial pneumonia and gastrointestinal bleeding in bedridden patients receiving tube feeding. A total of 116 bedridden hospitalized patients receiving tube feeding, of which 80 were supported by percutaneous endoscopic gastrostomy and 36 by nasogastric tube, were included in the present study. The patients were divided into two groups: 62 patients treated with PPI (PPI group) and 54 patients without PPI (non-PPI group). Mortality due to nosocomial pneumonia was evaluated using the Kaplan-Meier approach and the log-rank test. A total of 36 patients (31%) died of nosocomial pneumonia during the observation period; the mortality rate due to nosocomial pneumonia was significantly higher in the PPI group than in the non-PPI group (P = 0.0395). Cox proportional hazard analysis showed that the use of PPI and lower levels of serum albumin were independent predictors of 2-year mortality due to nosocomial pneumonia. Gastrointestinal bleeding was observed in four patients in the non-PPI group (7.7%) and in one patient in the PPI group (1.6%); there was no significant difference between the two groups. The use of PPI in bedridden tube-fed patients was independently associated with mortality due to nosocomial pneumonia, and the PPI group had a non-significant lower incidence of gastrointestinal bleeding than the non-PPI group. Geriatr Gerontol Int 2018; ••: ••-••. © 2018 The Authors Geriatrics & Gerontology International published by John Wiley & Sons Australia, Ltd on behalf of Japan Geriatrics Society.

  3. Immediate Tube Feeding after Percutaneous Endoscopic Gastrostomy: Early Return to Goal Tube Feeds without Added Complications.

    PubMed

    Lamb, Laura C; Jayaraman, Vijay; Montgomery, Stephanie C; Umer, Affan; Shapiro, David S; Feeney, James M

    2017-02-01

    Percutaneous endoscopic gastrostomy (PEG) is frequently performed for delivery of nonoral enteral nutrition (EN) in critically ill patients. Tube-based supplement initiation is often delayed for a variety of reasons despite evidence that EN interruption results in worse outcomes. To determine if early initiation of EN after PEG placement is safe and well-tolerated in critically ill patients and if early initiation of EN results in more goal-accomplished days of EN. A retrospective chart review of patients who underwent PEG and at least 24 hours of EN. Patients were stratified according to time to tube- feed initiation: immediate (< one hour), early (one to four hours), and late (four to 24 hours). 'Ihe three groups were similar with respect to demographics, comorbidities, and 30-day mortality. Sixty-one percent of patients in the immediate group were advanced to the previously-met goal EN rates compared to 24% and 18% in the early and delayed groups, respectively (P < .0001). Immediate reinitiation of nonoral EN after PEG procedure is safe and is associated with reaching goal nutrition faster.

  4. Dynamic tube movement after reimplantation of Ahmed glaucoma valve in a child with glaucoma in aphakia

    PubMed Central

    Senthil, Sirisha; Badakare, Akshay

    2014-01-01

    A 10-year-old girl underwent an Ahmed glaucoma valve (AGV) implantation as a primary procedure for glaucoma in aphakia due to congenital cataract surgery. Following an unintended accidental excision of AGV tube during bleb revision for hypertensive phase, AGV was explanted and a second AGV was implanted in the same quadrant after 2 weeks. This resulted in a rare complication of dynamic tube movement in the anterior chamber with tube corneal touch and localised corneal oedema. Excision of the offending unstable tube and placement of a paediatric AGV in a different quadrant led to resolution of this complication, stable vision and well-controlled intraocular pressure. This case highlights the possible causes of dynamic tube, related complications and its management. This case also highlights the importance of understanding the various physiological phases after glaucoma drainage device implantation and their appropriate management. PMID:24695662

  5. Compliance with recommendations for tympanostomy tube follow-up: patient characteristics.

    PubMed

    Kao, Richard; Kirse, Daniel J; Evans, Adele K

    2014-09-01

    (1) To determine the percentage of otherwise healthy patients achieving "graduation," or postoperative compliance achieving complete problem resolution and discharge from the otolaryngologist's care, after tympanostomy tube placement. (2) To analyze follow-up behaviors and patient characteristics influencing the likelihood of graduation. Retrospective cohort study. Tertiary care hospital. Analysis of details of tympanostomy tube placements performed from 2004 to 2011 by 2 pediatric otolaryngologists for children aged 0 to 18 years. Exclusion criteria were clearly defined craniofacial anomalies, cleft palates, and other ongoing postoperative care. The remaining study subjects were categorized into 3 groups. Graduation (GRAD) subjects achieved discharge from care with "follow-up pro re nata" status. LOST<2Y subjects had not attended scheduled follow-up in <2 years. LOST≥2Y subjects had no follow-up in ≥2 years. A total of 1454 pediatric subjects were included. GRADs constituted only 25.6% of the subject pool; 22.1% were LOST<2Y, and 52.3% were LOST≥2Y. Statistically significant factors in achieving graduation were total number of follow-up visits, total duration of follow-up, compliance with first postoperative visit, patient age, insurance type, and distance between home and practice. Rate of graduation, or postoperative compliance achieving complete problem resolution, of otherwise healthy tympanostomy tube patients is low despite perioperative discussions of the importance of proper follow-up. Higher graduation rates are associated with increasing number of follow-up visits and duration, younger patient age, private insurance, and proximity to the practice. Compliance with attending the first postoperative visit may be an early marker for increased likelihood of graduation. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  6. Use of Noninvasive Ventilation During Feeding Tube Placement.

    PubMed

    Banfi, Paolo; Volpato, Eleonora; Valota, Chiara; D'Ascenzo, Salvatore; Alunno, Chiara Bani; Lax, Agata; Nicolini, Antonello; Ticozzi, Nicola; Silani, Vincenzo; Bach, John R

    2017-11-01

    Parenteral nutrition is indicated in amyotrophic lateral sclerosis (ALS) when dysphagia, loss of appetite, and difficulty protecting the airways cause malnutrition, severe weight loss, dehydration, and increased risk of aspiration pneumonia. The aim of this review is to compare percutaneous endoscopic gastrostomy (PEG), radiologically inserted G-tube (RIG), and percutaneous radiologic gastrostomy (PRG) in patients with ALS, performed with or without noninvasive ventilation (NIV). We searched PubMed, MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), the EBSCO Online Research Database, and Scopus up to December 2015. A priori selection included all randomized controlled trials (RCTs), quasi-randomized trials, and prospective and retrospective studies. The primary outcome was 30-d survival. We found no RCTs or quasi-RCTs. Seven studies about the implementation of the PEG/RIG procedure during the use of NIV and 5 studies without NIV were included. In another study of 59 subjects undergoing open gastrostomy, all with vital capacity < 30% of normal, 18 of whom were dependent on continuous NIV at full ventilatory support settings, there were no respiratory complications. Thus, the use of NIV during the implementation of these procedures, especially when used at full ventilatory support settings of pressure preset 18-25 cm H 2 O, can support alveolar ventilation before, during, and after the procedures and prevent respiratory complications. The procedures investigated appear equivalent, but the methodological quality of the studies could be improved. Possible benefits with regard to nutrition parameters, quality of life, and psychological features need to be further investigated. Copyright © 2017 by Daedalus Enterprises.

  7. Ozone production of hollow-needle-to-mesh negative corona discharge enhanced by dielectric tube on the needle electrode

    NASA Astrophysics Data System (ADS)

    Pekárek, Stanislav

    2014-12-01

    For the hollow-needle-to-mesh negative corona discharge in air, we studied the effect of placing the dielectric tube on the needle electrode and the effect of various positions of the end of this tube with respect to the tip of the needle electrode on the concentration of ozone produced by the discharge, the ozone production yield and the discharge V-A characteristics. We found that the placement of the dielectric tube on the needle electrode with a suitable position of this tube end with respect to the tip of the needle electrode for a particular discharge power led to a more than fourfold increase in the concentration of ozone produced by the discharge and also, for a constant airflow, the ozone production yield.

  8. A prospective randomized trial of tapered-cuff endotracheal tubes with intermittent subglottic suctioning in preventing ventilator-associated pneumonia in critically ill patients.

    PubMed

    Mahmoodpoor, Ata; Hamishehkar, Hadi; Hamidi, Masoud; Shadvar, Kamran; Sanaie, Sarvin; Golzari, Samad Ej; Khan, Zahid Hussain; Nader, Nader D

    2017-04-01

    Endotracheal tube placement is necessary for the control of the airway in patients who are mechanically ventilated. However, prolonged duration of endotracheal tube placement contributes to the development of ventilator-associated pneumonias (VAPs). The aim of this study was to evaluate whether subglottic suctioning using TaperGuard EVAC tubes was effective in decreasing the frequency of VAP. A total of 276 mechanically ventilated patients for more than 72 hours were randomly assigned to group E (EVAC tube) and group C (conventional tube). All patients received routine care including VAP prevention measures during their intensive care unit stay. In group E, subglottic suctioning was performed every 6 hours. Outcome variables included incidence VAP, intensive care unit length of stay, and mortality. Frequency of intraluminal suction, mechanical ventilation-free days, reintubation, the ratio of arterial oxygen partial pressure to fractional inspired oxygen and mortality rate were similar between the 2 groups (P > .05). The mean cuff pressure in group E was significantly less than that in group C (P < .001). Ventilator-associated pneumonia was significantly less in group E compared with group C (P = .015). The use of intermittent subglottic secretion suctioning was associated with a significant decrease in the incidence of the VAP in critically ill patients. However, larger multicenter trials are required to arrive at a concrete decision on routine usage of TaperGuard tubes in critical care settings. Published by Elsevier Inc.

  9. Clinical features and outcomes of delayed perforation after endoscopic submucosal dissection for early gastric cancer.

    PubMed

    Hanaoka, N; Uedo, N; Ishihara, R; Higashino, K; Takeuchi, Y; Inoue, T; Chatani, R; Hanafusa, M; Tsujii, Y; Kanzaki, H; Kawada, N; Iishi, H; Tatsuta, M; Tomita, Y; Miyashiro, I; Yano, M

    2010-12-01

    Perforation is a major complication of endoscopic submucosal dissection (ESD) for early gastric cancer (EGC). However, there have been no reports on delayed perforation after ESD for EGC. We aimed to elucidate the incidence and outcomes of delayed perforation after ESD. Clinical courses in 1159 consecutive patients with 1329 EGCs who underwent ESD were investigated. Delayed perforation occurred in six patients (0.45 %). All these patients had complete en bloc resection without intraoperative perforation during ESD. Five of six perforations were located in the upper third of the stomach, while one lesion was found in the middle third. Symptoms of peritoneal irritation with rebound tenderness presented within 24 h after ESD in all cases. One patient did not require surgery because the symptoms were localized, and recovered with conservative antibiotic therapy by nasogastric tube placement. The remaining five patients required emergency surgery. There was no mortality in this case series. © Georg Thieme Verlag KG Stuttgart · New York.

  10. The effect of cuff presence and cuff inflation on airway pressure in a canine tracheostomy tube model.

    PubMed

    Wignall, Jamie R; Baines, Stephen J

    2014-01-01

    To evaluate the effect of cuff presence and cuff inflation on airway pressure in an inspiratory model of canine tracheostomy. Ex vivo experimental study. Cadaver tracheas from Beagle dogs were attached aborally to a vacuum. Airway pressure and flow rate was measured before and after placement of tracheostomy tubes. None. Adult uncuffed tubes and cuffed tracheostomy tubes (sizes 4, 6, 8, and 10) were placed within tracheas. Cuffs were investigated without inflation and at maximum cuff inflation. Airway pressure was measured at constant airflow rates at 30 and 60 L/min. At set flow rates, airway pressures of tracheostomy tubes were compared to the intact trachea. A size 4 uncuffed tracheostomy tube showed the lowest airway pressure and a size 4 cuffed trachestomy tube with inflation showed the highest airway pressures. For sizes 6, 8, and 10 tubes, the presence of a cuff with and without inflation significantly increased airway pressure. Inflation of a cuff always significantly increased airway pressure. Similar pressure is seen between sizes 4 and 6 uncuffed tubes. Cuffed tracheostomy tubes should not be used unless specifically indicated due to increased airway pressure. © Veterinary Emergency and Critical Care Society 2013.

  11. 7. View showing placement of timber deck placement on chord ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. View showing placement of timber deck placement on chord and built up construction of top chord and continuous construction through top panel points, eye bar construction on bottom chord - Bridge No. 2.4, Spanning Boiling Fork Creek at Railroad Milepost JC-2.4, Decherd, Franklin County, TN

  12. Social Work Program. Field Placement Manual for Social Work Field Placement I, Social Work Field Placement II.

    ERIC Educational Resources Information Center

    Miller, Howard J.; And Others

    This document is a manual for a social work field placement program. The social work field placement is described as a learning experience designed to translate the students' interests, interpersonal abilities, and academic knowledge and theory into the capability of enabling others to solve problems. Expectations of skills to be learned in the…

  13. Transient Tachypnea of the Newborn (TTN)

    MedlinePlus

    ... newborn receives IV fluids. Sometimes babies can take breast milk or formula through a nasogastric (NG) or orogastric ( ... of these tubes, ask the doctor about providing breast milk for your baby. Symptoms of transient tachypnea usually ...

  14. Spontaneously removed biliary stent drainage versus T-tube drainage after laparoscopic common bile duct exploration.

    PubMed

    Xu, Yakun; Dong, Chengyong; Ma, Kexin; Long, Fei; Jiang, Keqiu; Shao, Ping; Liang, Rui; Wang, Liming

    2016-09-01

    Several studies have shown the safety and feasibility of laparoscopic common bile duct exploration (LCBDE) as a minimally invasive treatment options for choledocholithiasis. Use of T-tube or biliary stent drainage tube placement after laparoscopic choledochotomy for common bile duct (CBD) stones is still under debate. This study tried to confirm the safety of spontaneously removable biliary stent in the distal CBD after LCBDE to allow choledochus primary closure. A total of 47 patients with choledocholithiasis underwent LCBDE with primary closure and internal drainage using a spontaneously removable biliary stent drainage tube (stent group, N = 22) or T-tube (T-tube group, N = 25). Operative parameters and outcomes are compared. Surgical time, intraoperative blood loss, length of hospital stay, drainage tube removal time, postoperative intestinal function recovery, and cost of treatment were all significantly lower in the stent group as compared to that in the T-tube group (P < 0.05 for all). Otherwise, Bile leakage between the two groups had no significant difference (P > 0.05). The biliary stent drainage tube was excreted spontaneously 4 to 14 days after surgery with the exception of one case, where endoscopic removal of biliary tube was required due to failure of its spontaneous discharge. LCBDE with primary closure and use of spontaneously removable biliary stent drainage showed advantage over the use of traditional T-tube drainage in patients with choledocholithiasis.

  15. Pontine infarction caused by medial branch injury of the basilar artery as a rare complication of cisternal drain placement.

    PubMed

    Horiuchi, Tetsuyoshi; Yamamoto, Yasunaga; Kuroiwa, Masafumi; Rahmah, Nunung Nur; Hongo, Kazuhiro

    2012-04-01

    We present a rare complication of cisternal drain placement during aneurysm surgery. A ruptured anterior communicating artery aneurysm was clipped through a right pterional approach. A cisternal drain was inserted from the retro-carotid to the prepontine cistern. Postoperatively, a left-sided paresis of the upper extremity had developed. A CT brain scan revealed that the drain was located between the pons and the basilar artery, resulting in a pontine infarction. Vascular neurosurgeons should keep this complication in mind when placing a cisternal drain tube. The drain tube should not be inserted too deep into the prepontine cistern. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    PubMed

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  17. Advanced statistical methods to study the effects of gastric tube and non-invasive ventilation on functional decline and survival in amyotrophic lateral sclerosis.

    PubMed

    Atassi, Nazem; Cudkowicz, Merit E; Schoenfeld, David A

    2011-07-01

    A few studies suggest that non-invasive ventilation (1) and gastric tube (G-tube) may have a positive impact on survival but the effect on functional decline is unclear. Confounding by indication may have produced biased estimates of the benefit seen in some of these retrospective studies. The objective of this study was to evaluate the effects of G-tube and NIV on survival and functional decline using advanced statistical models that adjust for confounding by indications. A database of 331 subjects enrolled in previous clinical trials in ALS was available for analysis. Marginal structural models (MSM) were used to compare the mortality hazards and ALSFRS-R slopes between treatment and non-treatment groups, after adjusting for confounding by indication. Results showed that the placement of a G-tube was associated with an additional 1.42 units/month decline in the ALSFRS-R slope (p < 0.0001) and increased mortality hazard of 0.28 (p = 0.02). The use of NIV had no significant effect on ALSFRS-R decline or mortality. In conclusion, marginal structural models can be used to adjust for confounding by indication in retrospective ALS studies. G-tube placement could be followed by a faster rate of functional decline and increased mortality. Our results may suffer from some of the limitations of retrospective analyses.

  18. SVC obstruction and stridor relieved by nasogastric tube insertion

    PubMed Central

    Molena, Emma J.; Krishnamoorthy, Ashwin; Praveen, Coimbatore

    2016-01-01

    Achalasia is an idiopathic motility disorder of the oesophagus of increasing incidence. It is characterized by aperistalsis of the lower oesophagus and failure of relaxation of the lower oesophageal sphincter. Patients classically present with chronic symptoms of dysphagia, chest pain, weight loss and regurgitation, and they commonly suffer pulmonary complications such as recurrent microaspiration of static, retained food contents of the upper oesophagus. However, it has also been described, uncommonly, to present with megaoesophagus and secondary tracheal compression. We present a case of megaoesophagus secondary to achalasia which presented with stridor and signs of acute superior vena caval obstruction. PMID:26933001

  19. SVC obstruction and stridor relieved by nasogastric tube insertion.

    PubMed

    Molena, Emma J; Krishnamoorthy, Ashwin; Praveen, Coimbatore

    2016-03-01

    Achalasia is an idiopathic motility disorder of the oesophagus of increasing incidence. It is characterized by aperistalsis of the lower oesophagus and failure of relaxation of the lower oesophageal sphincter. Patients classically present with chronic symptoms of dysphagia, chest pain, weight loss and regurgitation, and they commonly suffer pulmonary complications such as recurrent microaspiration of static, retained food contents of the upper oesophagus. However, it has also been described, uncommonly, to present with megaoesophagus and secondary tracheal compression. We present a case of megaoesophagus secondary to achalasia which presented with stridor and signs of acute superior vena caval obstruction. Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2016.

  20. Selected Studies on Math Placement.

    ERIC Educational Resources Information Center

    Akst, Geoffrey; Hirsch, Lewis

    1991-01-01

    Drawing from a review of the literature and direct experience, this paper discusses key issues in developmental mathematics placement. First, the controversial practice of mandatory placement is examined, citing research results that support the practice and those that do not. Next, the diversity of developmental math placement standards is…

  1. Tracheostomy Tube Type and Inner Cannula Selection Impact Pressure and Resistance to Air Flow.

    PubMed

    Pryor, Lee N; Baldwin, Claire E; Ward, Elizabeth C; Cornwell, Petrea L; O'Connor, Stephanie N; Chapman, Marianne J; Bersten, Andrew D

    2016-05-01

    Advancements in tracheostomy tube design now provide clinicians with a range of options to facilitate communication for individuals receiving ventilator assistance through a cuffed tube. Little is known about the impact of these modern design features on resistance to air flow. We undertook a bench model test to measure pressure-flow characteristics and resistance of a range of tubes of similar outer diameter, including those enabling subglottic suction and speech. A constant inspiratory ± expiratory air flow was generated at increasing flows up to 150 L/min through each tube (with or without optional, mandatory, or interchangeable inner cannula). Driving pressures were measured, and resistance was calculated (cm H2O/L/s). Pressures changed with increasing flow (P < .001) and tube type (P < .001), with differing patterns of pressure change according to the type of tube (P < .001) and direction of air flow. The single-lumen reference tube encountered the lowest inspiratory and expiratory pressures compared with all double-lumen tubes (P < .001); placement of an optional inner cannula increased bidirectional tube resistance by a factor of 3. For a tube with interchangeable inner cannulas, the type of cannula altered pressure and resistance differently (P < .001); the speech cannula in particular amplified pressure-flow changes and increased tube resistance by more than a factor of 4. Tracheostomy tube type and inner cannula selection imposed differing pressures and resistance to air flow during inspiration and expiration. These differences may be important when selecting airway equipment or when setting parameters for monitoring, particularly for patients receiving supported ventilation or during the weaning process. Copyright © 2016 by Daedalus Enterprises.

  2. Three-finger tracheal palpation to guide endotracheal tube depth in children.

    PubMed

    Gamble, Jonathan J; McKay, William P; Wang, Andrew F; Yip, Kinsha A; O'Brien, Jennifer M; Plewes, Christopher E

    2014-10-01

    Accurate endotracheal tube (ETT) depth is critical, especially in children. The current tools used to guide appropriate ETT depth have significant limitations. To evaluate the utility of tracheal palpation in the neck to guide appropriate ETT placement in children. A prospective observational study with a convenience sample of 50 children was conducted. During intubation, an investigator palpated the trachea with three fingertips side-by-side extending upward from the suprasternal notch. The anesthesiologist advanced the ETT slowly until palpated at the sternal notch. The investigator stated ETT palpation certainty as 'strongly felt', 'weakly felt', or 'not felt.' Final ETT position was determined by bronchoscopy and categorized as 'ETT too shallow' (tip in proximal ¼ of trachea), 'ETT too deep' (tip in distal ¼ of trachea), or 'ETT placement satisfactory' (between those extremes). Thirty boys and 20 girls undergoing dental surgery with nasal intubation were recruited (median age 4.4 years; range 2.0-10.8). The ETT (all ≥4 mm ID) was palpable at the sternal notch in all patients: 46 of 50 strongly palpable and 4 of 50 weakly palpable. The experimental methods led to satisfactory ETT placement in 49 of 50 patients, too deep in 1 of 50 patients. Compared with the Pediatrics Advanced Life Support (PALS) predictive formula, satisfactory placement would have been 41 of 50 patients (P < 0.008). Number needed to treat is 6.3 for improvement over the PALS method. The use of tracheal palpation to guide ETT placement has excellent clinical performance and better guides appropriate ETT depth than the PALS formula in our study population. © 2014 John Wiley & Sons Ltd.

  3. The sky blue method as a screening test to detect misplacement of percutaneous endoscopic gastrostomy tube at exchange.

    PubMed

    Suzuki, Yutaka; Urashima, Mitsuyoshi; Yoshida, Hideki; Iwase, Tsuyoshi; Kura, Toshiroh; Imazato, Shin; Kudo, Michiaki; Ohta, Tomoyuki; Mizuhara, Akihiro; Tamamori, Yutaka; Muramatsu, Hirohito; Nishiguchi, Yukio; Nishiyama, Yorihiro; Takahashi, Mikako; Nishiwaki, Shinji; Matsumoto, Masami; Goshi, Satoshi; Sakamoto, Shigeo; Uchida, Nobuyuki; Ijima, Masashi; Ogawa, Tetsushi; Shimazaki, Makoto; Takei, Shinichi; Kimura, Chikou; Yamashita, Satoyoshi; Endo, Takao; Nakahori, Masato; Itoh, Akihiko; Kusakabe, Toshiro; Ishizuka, Izumi; Iiri, Takao; Fukasawa, Shingo; Arimoto, Yukitsugu; Kajitani, Nobuaki; Ishida, Kazuhiko; Onishi, Koji; Taira, Akihiko; Kobayashi, Makoto; Itano, Yasuto; Kobuke, Toshiya

    2009-01-01

    During tube exchange for percutaneous endoscopic gastrostomy (PEG), a misplaced tube can cause peritonitis and death. Thus, endoscopic or radiologic observation is required at tube exchange to make sure the tube is placed correctly. However, these procedures cost extensive time and money to perform in all patients at the time of tube exchange. Therefore, we developed the "sky blue method" as a screening test to detect misplacement of the PEG tube during tube exchange. First, sky blue solution consisting of indigocarmine diluted with saline was injected into the gastric space via the old PEG tube just before the tube exchange. Next, the tube was exchanged using a standard method. Then, we checked whether the sky blue solution could be collected through the new tube or not. Finally, we confirmed correct placement of the tube by endoscopic or radiologic observation for all patients. A total of 961 patients were enrolled. Each tube exchange took 1 to 3 minutes, and there were no adverse effects. Four patients experienced a misplaced tube, all of which were detectable with the sky blue method. Diagnostic parameters of the sky blue method were as follows: sensitivity, 94% (95%CI: 92-95%); specificity, 100% (95%CI: 40-100%); positive predictive value, 100% (95%CI: 100-100%); negative predictive value, 6% (95%CI: 2-16%). These results suggest that the number of endoscopic or radiologic observations to confirm correct replacement of the PEG tube may be reduced to one fifteenth using the sky blue method.

  4. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.

    PubMed

    Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael

    2017-09-01

    Purpose  Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods  Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results  The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm 2 (flat panel detector systems: 155 cGy*cm 2 ; X-ray image intensifier: 175 cGy*cm 2 ). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm 2 ), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT - flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion  In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe

  5. Why good placements matter: Pre-placement and placement risk factors associated with mental health disorders in pre-school children in foster care.

    PubMed

    Hillen, Thomas; Gafson, Leonie

    2015-07-01

    Pre-school children placed in local authority care show elevated rates of mental health disorders when compared to the general population. This study investigated risk factors for mental health disorders relating to the period prior to entering care and while in care. A representative sample of 43 children in care aged 0-72 months in an inner London borough underwent comprehensive multidimensional assessments. Presence of emotional, behavioural, attachment and adaptive disorders was ascertained. Exposure to two pre-placement risk factors and six placement risk factors was compared between children with and without a disorder. A total of 26 children (60.5%) had at least one mental health disorder. The two pre-placement risk factors, multiple types of maltreatment and entry into care after the age of 6 months, were both significantly associated with mental health disorders. The three placement risk factors of sudden placement moves, multiple placement moves and child-carer alienation showed a significant association with mental health disorders. There was a strong correlation between the number of risk factors and the number of co-morbid mental health disorders per child (r = .67, p < .001). In conclusion, this study identified five modifiable risk factors related to the quality of safeguarding and fostering services which showed a significant association with pre-school mental health. © The Author(s) 2014.

  6. Tube-in-tube thermophotovoltaic generator

    DOEpatents

    Ashcroft, J.; Campbell, B.; DePoy, D.

    1998-06-30

    A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell. 8 figs.

  7. Tube-in-tube thermophotovoltaic generator

    DOEpatents

    Ashcroft, John; Campbell, Brian; DePoy, David

    1998-01-01

    A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell.

  8. A Format for Phylogenetic Placements

    PubMed Central

    Matsen, Frederick A.; Hoffman, Noah G.; Gallagher, Aaron; Stamatakis, Alexandros

    2012-01-01

    We have developed a unified format for phylogenetic placements, that is, mappings of environmental sequence data (e.g., short reads) into a phylogenetic tree. We are motivated to do so by the growing number of tools for computing and post-processing phylogenetic placements, and the lack of an established standard for storing them. The format is lightweight, versatile, extensible, and is based on the JSON format, which can be parsed by most modern programming languages. Our format is already implemented in several tools for computing and post-processing parsimony- and likelihood-based phylogenetic placements and has worked well in practice. We believe that establishing a standard format for analyzing read placements at this early stage will lead to a more efficient development of powerful and portable post-analysis tools for the growing applications of phylogenetic placement. PMID:22383988

  9. A format for phylogenetic placements.

    PubMed

    Matsen, Frederick A; Hoffman, Noah G; Gallagher, Aaron; Stamatakis, Alexandros

    2012-01-01

    We have developed a unified format for phylogenetic placements, that is, mappings of environmental sequence data (e.g., short reads) into a phylogenetic tree. We are motivated to do so by the growing number of tools for computing and post-processing phylogenetic placements, and the lack of an established standard for storing them. The format is lightweight, versatile, extensible, and is based on the JSON format, which can be parsed by most modern programming languages. Our format is already implemented in several tools for computing and post-processing parsimony- and likelihood-based phylogenetic placements and has worked well in practice. We believe that establishing a standard format for analyzing read placements at this early stage will lead to a more efficient development of powerful and portable post-analysis tools for the growing applications of phylogenetic placement.

  10. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush.

    PubMed

    Groth, Sylvia L; Greider, Kelsi L; Sponsel, William Eric

    2015-01-01

    To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. Case series. Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.

  11. Rectal tube drainage reduces major anastomotic leakage after minimally invasive rectal cancer surgery.

    PubMed

    Yang, C-S; Choi, G-S; Park, J S; Park, S Y; Kim, H J; Choi, J-I; Han, K S

    2016-12-01

    Anastomotic leakage is the most serious complication following low anterior resection for rectal cancer and is a major cause of postoperative morbidity and mortality. The object of the present study was to investigate whether rectal tube drainage can reduce anastomotic leakage after minimally invasive rectal cancer surgery. Three hundred and seventy-four patients who underwent laparoscopic or robotic LAR for tumours located ≤ 15 cm above the anal verge between 1 April 2012 and 31 October 2014 were assessed retrospectively. Of these, 107 with intermediate risk of anastomotic leakage received transanal rectal tube drainage. The rectal tube group was matched by propensity score analysis with patients not having rectal tube drainage, giving 204 patients in the study. Covariates for propensity score analysis included age, sex, body mass index, tumour height from the anal verge and preoperative chemoradiation. Patient demographics, tumour location, preoperative chemoradiation and operative results were similar between the two groups. The overall leakage rate was 10.8% (22/204), with no significant difference between the rectal tube group (9.8%) and the nonrectal tube group (11.8%, P = 0.652). Of the patients with anastomotic leakage, major leakage requiring reoperation developed in 11.8% of those without and 3.9% of those with a rectal tube. On multivariate analysis, age over 65 years and nonuse of a rectal tube were found to be independent risk factors for major anastomotic leakage. Rectal tube placement may be a safe and effective method of reducing the rate of major anastomotic leakage, alleviating the clinical course of leakage following minimally invasive rectal cancer surgery. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  12. Supportive care for children with cancer. Guidelines of the Childrens Cancer Study Group. The use of nutritional therapy.

    PubMed

    Lukens, J N

    1984-01-01

    Nutritional support for children with cancer is predicated on the belief that optimal nutrition promotes tolerance of anti-neoplastic therapy and preserves immunologic responsiveness. The use of nutritional support is based on the assumption that there is effective therapy for the primary disease and that there will be a predictable period of nutritional stress. The most common nutritional problem is posed by the failure of sick children willingly to eat enough to maintain nutritional homeostasis. Supplementation of oral intake with a nutritional formula given by a small-bore nasogastric tube is simple, effective, and economical. If the sum of oral and tolerated nasogastric tube feedings is less than that required for optimal nutrition, unmet needs may be satisfied by nutrients given into a peripheral vein. Total parenteral nutrition, given by central vein, is reserved for situations in which the combination of enteral and peripheral venous alimentation is inadequate.

  13. Successful surgical treatment of left atrioesophageal fistula following atrial ablation.

    PubMed

    Takahashi, Toru; Mohara, Jun; Ogawa, Hiroomi; Igarashi, Takamichi; Motegi, Yoko

    2018-01-23

    A 69-year-old male had catheter-based ablation for atrial fibrillation. He was admitted with high fever and had neurological disorder; he was diagnosed with atrioesophageal fistula by CT scan. Intraoperative findings showed that the fistula existed adjacent to the left lower pulmonary vein with a vegetation. The esophageal fistula was repaired, and the left atrial fistula was closed. A nasogastric tube tip was placed in the esophagus for decompression and advanced into the stomach for nutritional support. After vomiting, the patient showed loss of consciousness and left hemiplegia. CT scan revealed a micro-air embolism to the brain. The nasogastric tube tip was pulled back into the esophagus. Gastrointestinal fiberscopy showed a pinhole at the fistula, and a percutaneous endoscopic gastrostomy was made. After conservative treatment, the esophageal fistula was closed and mediastinitis was improved. He was discharged with a little neurological deficit.

  14. ESL Placement and Schools

    PubMed Central

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra; Frisco, Michelle

    2010-01-01

    In this study, the authors explore English as a Second Language (ESL) placement as a measure of how schools label and process immigrant students. Using propensity score matching and data from the Adolescent Health and Academic Achievement Study and the National Longitudinal Study of Adolescent Health, the authors estimate the effect of ESL placement on immigrant achievement. In schools with more immigrant students, the authors find that ESL placement results in higher levels of academic performance; in schools with few immigrant students, the effect reverses. This is not to suggest a one-size-fits-all policy; many immigrant students, regardless of school composition, generational status, or ESL placement, struggle to achieve at levels sufficient for acceptance to a 4-year university. This study offers several factors to be taken into consideration as schools develop policies and practices to provide immigrant students opportunities to learn. PMID:20617111

  15. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu

    2018-05-01

    To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.

  16. Prophylactic Percutaneous Endoscopic Gastrostomy (PEG) - The Importance of Nutritonal Support in Patients with Head and Neck Cancers (HNCs) or Neurogenic Dysphagia (ND).

    PubMed

    Cristian, D; Poalelungi, A; Anghel, A; Burcoş, T; Grigore, R; Berteşteanu, S; Richiteanu, G; Grama, F

    2015-01-01

    We evaluated the effectiveness and safety of prophylactic PEG performed for the enteral nutrition support during the oncological treatment of patients with HNCs and as a part of the management of neurological patients experiencing neurogenic dysphagia. In 2013 we followed up on a group of 23 HNC patients subjected to prophylactic PEG. We assessed the duration of the procedure, intraprocedural incidents and their causes, time to tube-refeeding and discharge after intervention, post interventional analgesia, early and late complications,toleration, costs and postoperative course of these patients after radical surgery maintaining PEG in place. In parallel we followed up on a group of 10 neurological patients who have undergone a PEG placement to improve the nutrional status and to prevent recurrent chest infections due to ND related silent aspiration. The procedures were performed under sedation with Midazolam and the mean duration was about 7 minutes.Postoperative analgesia was minimal. Refeeding through the tube was initiated 2-4h hours later and the patients were discharged 12-24h after the procedure. Early complications were not observed and later we noted 2 cases of peristomal infections, succesfully managed conservatively. After oncologic surgery we noted 2 (8.69%) pharyngocutaneous fistulas.Conservative care obliterated the fistulas at 6 weeks, maintaining the feeding tube in place. We also compared the results with a group of 27 patients fed through the naso-gastric tube and a group of 20 cases with open gastrotomy-tube prophylactically inserted. The 10 neurological patients had varied conditions but degenerative diseases like motor neuron disease (3 cases" 30%) and multiple sclerosis (2 cases -20%) took the lead we encountered one case of peristomal infection and one case of tube blockage resolved by replacement. We evaluated the nutritional status by controling the weight of these patients before and after PEG placement. A mean weight gain of 3.1 kg(range 1

  17. Nurse and patient factors that influence nursing time in chest tube management early after open heart surgery: A descriptive, correlational study.

    PubMed

    Cook, Myra; Idzior, Laura; Bena, James F; Albert, Nancy M

    2017-10-01

    Determine nurse characteristics and patient factors that affect nurses' time in managing chest tubes in the first 24-hours of critical-care stay. Prospective, descriptive. Cardiovascular critical-care nurses and post-operative heart surgery patients with chest tubes were enrolled from a single center in Ohio. Nurses completed case report forms about themselves, comfort and time in managing chest tubes, chest tube placement and management factors. Analysis included correlational and comparative statistics; Bonferroni corrections were applied, as appropriate. Of 29 nurses, 86.2% were very comfortable managing chest tubes and oozing/non-secure dressings, but only 41.4% were very comfortable managing clogged chest tubes. Of 364 patients, mean age was 63.1 (±12.3) years and 36% had previous heart surgery. Total minutes of chest tube management was higher with≥3 chest tubes, tube size <28 French, and when both mediastinal and pleural tubes were present (all p<0.001). In the first 4-hours, time spent on chest tubes was higher when patients had previous cardiac surgeries (p≤0.002), heart failure (p<0.001), preoperative anticoagulant medications (p=0.031) and reoperation for postoperative bleeding/tamponade (p=0.005). Time to manage chest tubes can be anticipated by patient characteristics. Nurse comfort with chest tube-related tasks affected time spent on chest tube management. Published by Elsevier Ltd.

  18. 5 CFR 9901.516 - Internal placement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Internal placement. 9901.516 Section 9901... PERSONNEL SYSTEM (NSPS) Staffing and Employment External Recruitment and Internal Placement § 9901.516 Internal placement. (a) Determining levels of work and movement within and across career groups. The...

  19. VR Placement Policy and Field Office Production. Studies in Placement Monograph No. 5.

    ERIC Educational Resources Information Center

    Pretz, David S.; And Others

    A study examined the relationship between vocational education rehabilitation agency placement policy and field office productivity. A total of 112 counselors and 25 supervisors from twenty-two Division of Vocational Rehabilitation field offices from seven states were given questionnaires covering different facets of placement policy including…

  20. Choledochorraphy (primary repair) versus t-tube drainage after open choledochotomy.

    PubMed

    Saeed, Nadia; Nasir, Muhammad Tauqeer; Khan, Muhammad Iqbal; Channa, Ghulam Asghar

    2012-01-01

    T-tube drainage used to be standard practice after surgical choledochotomy, but there is now a tendency in some canters to close the common bile duct primarily. This study was designed to compare the clinical results of primary closure with T-tube drainage after open choledocotomy and assess the safety of primary closure for future application. This study was conducted at surgical Unit-3, ward 26 Jinnah Postgraduate Medical Centre Karachi, from January 2007 to January 2008. Forty patients were included in this study out of which 20 underwent primary closure and 20 T-tube placements. It was Quasi-experimental, non-probability, purposive sampling. Main outcome measures were operating time, duration of hospital stay, and postoperative complications. SPSS-10 was used for data analysis. The age of patients in the study ranged from 29-83 years. There were 3 male while 37 female patients. Group-1 consisted of 20 patients underwent primary closure after choledocotomy, while Group-2 also consisted of 20 patients underwent T-tube drainage after duct exploration. Mean hospital stay in Group-1 patients was 7.63 days while in group 2 it was 13.6 days. Overall complication rate in group 1 was 15%, biliary leakage in 1 (5%), jaundice in 1 (5%), wound infection in 1 (5%). No re-exploration was required in Group-1. In Group-2 overall complication rate was 30%, biliary leakage in 2 (2%), jaundice in 1 (5%), dislodgement of T-tube in 1 (5%), wound infection in 1 (5%), and sepsis in 1 (5%) patients. Re-exploration was done in one patient. Primary closure of Common Bile Duct (CBD) is a safe and cost-effective alternative procedure to routine T-tube drainage after open choledocotomy.

  1. Humanitarian engineering placements in our own communities

    NASA Astrophysics Data System (ADS)

    VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.

    2010-05-01

    There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be transformative for both the student and the community, although this potential is not always seen. In order to investigate the role of local placements, qualitative research interviews were conducted. Thirty-two semi-structured research interviews were conducted and analysed, resulting in a distinct outcome space. It is concluded that local humanitarian engineering placements greatly complement international placements and are strongly recommended if international placements are conducted. More importantly it is seen that we are better suited to address the marginalised in our own community, although it is often easier to see the needs of an outside populace.

  2. Placement and Follow-up.

    ERIC Educational Resources Information Center

    Shippen, Samuel Joseph, Ed.; Wasil, Raymond A., Ed.

    This document contains a compilation of original manuscripts written by competent authorities in the field of job placement services for students. Viewing placement as both a product and an integral part of a developmental process, these papers are divided into the following six topical areas: (1) information, (2) exploration, (3) counseling, (4)…

  3. Consideration of alternative designs for a Percutaneous Endoscopic Gastrostomy feeding tube

    NASA Astrophysics Data System (ADS)

    Yerrabolu, Santosh Rohit

    and/or 3-D printing are proposed for manufacturing of the product. Radio Frequency Glow Discharge Treatment is proposed as a sterilizing technique. Further investigations suggested are pilot Finite Element Analysis of the biomechanics involved and the subsequent validation and optimization of the conceptual designs apart from pursuing materials performance evaluation with stomach tissue-skin composites and long-term placement of tubes/ catheters at variable surface roughness profiles, filler materials, modulus of rigidities, tube-pull-through speeds and tissue stretch ratios.

  4. Weight-for-height values and limb anthropometric composition of tube-fed children with quadriplegic cerebral palsy.

    PubMed

    Kong, Chi-Keung; Wong, Heung-Sang Stephen

    2005-12-01

    Research has shown that growth retardation among children with quadriplegic cerebral palsy (CP) is often attributed to feeding dysfunction and malnutrition. The study compared weight-for-height values and limb anthropometric composition of nasogastric and gastrostomy tube-fed children with quadriplegic CP with those of orally fed children with quadriplegic CP and normal children, to examine the plausible effects of tube feeding on weight-for-height, fat, and muscle values for children with quadriplegic CP. Triceps, anterior mid-thigh, and medial calf skinfold thicknesses and the corresponding circumferences of the right or less affected side were measured. The subjects consisted of 119 normal children and 62 orally fed and 48 tube-fed children with quadriplegic CP. Body weight and height were recorded. For children with CP whose height could not be measured, height was estimated from the ulna length. Weight-for-height z scores, limb skinfold thicknesses, fat areas, skinfold-corrected muscle girths, and muscle areas of the children were compared. Tube-fed children with CP had normal mean weight-for-height z scores. Weight-for-height z scores of the orally fed children with CP were significantly below those of normal children and tube-fed children with CP. For children with CP, whereas triceps skinfold thickness seemed to predict the mid-upper arm fat area correctly, leg skinfold thicknesses seemed to overestimate the corresponding fat areas. Stepwise multiple regression analysis showed that triceps skinfold thicknesses had good correlation (r = 0.86) and the presence of CP had nonsignificant correlation with mid-upper arm fat areas. Multiple regression analysis of fat areas with skinfold thicknesses and the presence of CP, however, showed that CP was correlated negatively (partial correlation of CP: thigh, -0.45; calf, -0.53) with thigh and calf fat areas. Although skinfold-corrected mid-upper arm muscle girths of children with CP were quite similar to those of

  5. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  6. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  7. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  8. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  9. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  10. J-tube technique for double-j stent insertion during laparoscopic upper urinary tract surgical procedures.

    PubMed

    Kim, Hyung Suk; Lee, Byung Ki; Jung, Jin-Woo; Lee, Jung Keun; Byun, Seok-Soo; Lee, Sang Eun; Jeong, Chang Wook

    2014-11-01

    Double-J stent insertion has been generally performed during laparoscopic upper urinary tract (UUT) surgical procedures to prevent transient urinary tract obstruction and postoperative flank pain from ureteral edema and blood clots. Several restrictive conditions that make this procedure difficult and time consuming, however, include the coiled distal ends of the flexible Double-J stent and the limited bending angle of the laparoscopic instruments. To overcome these limitations, we devised a Double-J stent insertion method using the new J-tube technique. Between July 2011 and May 2013, Double-J stents were inserted using the J-tube technique in 33 patients who underwent a laparoscopic UUT surgical procedure by a single surgeon. The mean stent placement time was 4.8±2.7 minutes, and there were no intraoperative complications. In conclusion, the J-tube technique is a safe and time-saving method for Double-J stent insertion during laparoscopic surgical procedures.

  11. What to do with medialized tympanostomy tubes? A survey of pediatric otolaryngologists.

    PubMed

    Bezdjian, Aren; Jiang, Joanna; Maby, Alexandra; Daniel, Sam J

    2018-01-01

    Tympanostomy tube placement is the most common surgical procedure performed in children. Medial migration of a tympanostomy tube is a rare occurrence where the tube migrates into the middle ear cavity as opposed to its normal extrusion into the external auditory canal. Whether medialized tympanostomy tubes should be surgically removed in asymptomatic patients is controversial. The objective of this study was to determine experience and management approach of medialized tympanostomy tubes among pediatric otolaryngologists. A 12-question cross-section survey was designed and distributed to the American Society of Pediatric Otolaryngology (ASPO) members. The survey study was granted McGill University institutional review board and ASPO research committee approval. The survey data were filtered and cross-tabulated. Descriptive statistics were generated. 128 pediatric otolaryngologists completed the 12-question survey. The majority of respondents had experienced at least one case of medialized tympanostomy tube (90.6%). The majority of patients (82.0%) were asymptomatic. 74 out of 128 respondents (57.8%) indicated that they would not remove a medialized tube in an asymptomatic patient. However, 7.0% of those respondents clarified that they would proceed to surgical removal if the patient were undergoing general anesthesia for another surgery. 30.5% of respondents indicated that they would surgically remove the tube even if the patient were asymptomatic. 6.3% of respondents indicated that opted management in children would be based on a shared decision with parents. Most respondents (80.5%) did not experience complications with surgical removal nor with elected observation. There is no consensus among pediatric otolaryngologists regarding the necessity of surgically removing a medialized tympanostomy tube in asymptomatic patients. The survey suggests that both options are acceptable. If observation is chosen, it is important that parents are well informed of the

  12. Possible consequences of operation with KIVN fuel elements in K Zircaloy process tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, P.A.

    1963-08-06

    From considerations of the results of experimental simulations of non-axial placement of fuel elements in process tubes and in-reactor experience, it is concluded that the ultimate outcome of a charging error which results in operation with one or more unsupported fuel elements in a K Zircaloy-2 process tube would be multiple fuel failure and failure of the process tube. The outcome of the accident is determined by the speed with which the fuel failure is detected and the reactor is shut down. The release of fission products would be expected to be no greater than that which has occurred followingmore » severe fuel failure incidents. The highest probability for fission product release occurs during the discharge of failed fuel elements, when a small fraction of the exposed uranium of the fuel element may be oxidized when exposed to air before the element falls into the water-filled discharge chute. The confinement and fog spray facilities were installed to reduce the amount of fission products which might escape from the reactor building after such an event.« less

  13. Duodenal Loop Obstruction as an Unusual Cause of Acute Pancreatitis: A Case Series.

    PubMed

    Lee, Hyeonmin; Choi, Yonghyeok; Jeong, Hyewon; Lim, Jae Kyu; Jung, Taeyoung; Han, Joung Ho; Park, Seon Mee

    2016-12-25

    Duodenal loop obstruction is an unusual cause of acute pancreatitis. Increased intraluminal pressure hinders pancreatic flow, causing dilatation of the pancreatic duct and inducing acute pancreatitis. We experienced three cases of acute pancreatitis that resulted from duodenal loop obstruction after (1) an esophagectomy with gastric pull-up procedure for esophageal cancer, (2) a gastrectomy with Billroth I reconstruction for gastric cancer, and (3) a gastrojejunostomy for abdominal trauma. An abdominal CT scan revealed a distended duodenal loop, dilated pancreatic duct, and inflamed pancreas with fluid collection. Acute pancreatitis with duodenal loop obstruction was diagnosed by abdominal pain, elevated serum amylase/lipase, and abdominal CT findings. Immediate decompression with a nasogastric tube was performed, and all patients showed improvement within one week after admission. Each patient was followed up for more than two years without recurrence. Our findings suggest the usefulness of nasogastric tube decompression as the first line of treatment for acute pancreatitis related to duodenal loop obstruction.

  14. Massive hemorrhage after Kasai portoenterostomy in a patient with a congenital extrahepatic portosystemic shunt, malrotation and a double aortic arch: report of a case.

    PubMed

    Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Tanaka, Yujiro; Sato, Kaori; Jimbo, Takahiro; Deie, Kyoichi; Koiwai, Kazuki; Nomura, Koji; Iwanaka, Tadashi

    2014-08-01

    A newborn female was transferred to our hospital presenting with severe respiratory distress. She underwent tracheal intubation and nasogastric tubing. Investigations revealed a congenital extrahepatic portosystemic shunt (CEPS) type 1, biliary atresia, heterotaxia, polysplenia, malrotation and a double aortic arch (DAA). She underwent the Kasai portoenterostomy and the Ladd procedure when she was 29 days old. On postoperative day 20, she developed sudden hematemesis with bright red blood. Endoscopy showed massive bleeding from an esophageal ulcer, and endoscopic therapy was performed successfully. During left thoracotomy, an aortoesophageal fistula (AEF) was detected and repaired by direct suturing. The postoperative course was uneventful. CEPS type 1 is commonly associated with other congenital malformations; however, there have been no previous reports of an association between CEPS and DAA. Nasogastric tube insertion in a patient with DAA can result in catastrophic AEF. The treatment strategy should be carefully considered in patients with CEPS type 1 and multiple congenital fetal anomalies.

  15. Preparation and characterization of spironolactone-loaded nano-emulsions for extemporaneous applications.

    PubMed

    Hallouard, François; Dollo, Gilles; Brandhonneur, Nolwenn; Grasset, Fabien; Corre, Pascal Le

    2015-01-15

    In neonates as well as in adults having swallowing difficulty, oral medication is given through a nasogastric tube making liquid formulations preferable. In this study, we present the high potential of nanometric emulsions formulated by spontaneous surfactant diffusion, as extemporaneous formulations of hydrophobic drug. Spironolactone used as hydrophobic drug model, was incorporated in oil before formulation at a concentration of 13.5mg/g oil. Then, all formulations were evaluated from pharmacotechnical and clinical standpoints, for their use in hospital or community pharmacy. The strength of this new liquid formulation lies on the simplicity, efficiency and reproducibility of their low energy process as on clinical aspects: high dose uniformity, facility to be administered through in nasogastric tube without any retention and a stability of 2 months at least compatible for an extemporaneous use. Moreover, this emulsion presented spironolactone content of 3.75 mg/ml among the most concentrated formulations published. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Sigmoid irrigation tube for the management of chronic evacuation disorders.

    PubMed

    Gauderer, Michael W L; Decou, James M; Boyle, John T

    2002-03-01

    Antegrade colonic irrigation, in which the right colon is accessed via appendicostomy or cecostomy, now is an important adjunct in the management of children with chronic evacuation disorders. However, in most children, the major area of dysfunction is the left rather than the right colon. The authors developed a simple, percutaneous endoscopic, laparoscopically controlled sigmoid irrigation tube placement and evaluated the results in 4 children. A rigid sigmoidoscope is advanced into the upper sigmoid and the loop brought in contact with the abdominal wall under laparoscopic control. A small skin incision is made and a needle pushed across the abdominal and sigmoid walls into the lumen of the sigmoidoscope. A guide wire is advanced through the needle into the scope and retrieved. After the scope is removed, a PEG-type catheter is attached to the guide wire and pulled back, securing the sigmoid loop to the abdominal wall. The tube is subsequently converted to a skin-level device by simply adding an external port valve. All 4 patients achieved prompt evacuation in the sitting position. Sigmoid tube for antegrade irrigation is an appealing alternative to conventional cecal access. The procedure is simple and may offer physiologic advantages. Copyright 2002 by W.B. Saunders Company.

  17. Avulsed Nasoenteric Bridle System Magnet as an Intranasal Foreign Body.

    PubMed

    Puricelli, Michael D; Newberry, Christopher Ian; Gov-Ari, Eliav

    2016-02-01

    Nasoenteric tubes provide short-term nutrition support to patients unable to take an adequate oral diet. Bridling systems may be used to secure tubes to guard against displacement. We present the first case of an avulsed magnet from a bridling system to raise awareness of this potential complication. The primary methods of securing a nasogastric tube are reviewed, and comparative assessment of the 3 main systems is presented. Diagnosis and management of nasal foreign bodies relevant to this case are reviewed and prevention/safety considerations discussed. © 2015 American Society for Parenteral and Enteral Nutrition.

  18. Genetic Algorithm Approaches for Actuator Placement

    NASA Technical Reports Server (NTRS)

    Crossley, William A.

    2000-01-01

    This research investigated genetic algorithm approaches for smart actuator placement to provide aircraft maneuverability without requiring hinged flaps or other control surfaces. The effort supported goals of the Multidisciplinary Design Optimization focus efforts in NASA's Aircraft au program. This work helped to properly identify various aspects of the genetic algorithm operators and parameters that allow for placement of discrete control actuators/effectors. An improved problem definition, including better definition of the objective function and constraints, resulted from this research effort. The work conducted for this research used a geometrically simple wing model; however, an increasing number of potential actuator placement locations were incorporated to illustrate the ability of the GA to determine promising actuator placement arrangements. This effort's major result is a useful genetic algorithm-based approach to assist in the discrete actuator/effector placement problem.

  19. The use of self-expanding silicone stents in esophageal cancer care: optimal pre-, peri-, and postoperative care.

    PubMed

    Martin, Robert; Duvall, Ryan; Ellis, Susan; Scoggins, Charles R

    2009-03-01

    Preoperative nutritional supplementation, management of esophageal leaks, and postoperative anastomotic strictures still remain common problems in the management of esophageal cancer. Jejunal feeding tubes, total parenteral nutrition (TPN) with nasogastric suction, and repeated esophageal dilations remain the most common treatments, respectively. The aim of this study was to evaluate the use of removable silicone stents in (1) the preoperative nutritional optimization during neoadjuvant therapy, (2) the management of perioperative anastomotic leak, and (3) the management of postoperative anastomotic strictures. Review of our prospectively maintained esophageal database identified 15 patients who had removable self-expanding silicone stents placed in the management of one of these three management problems from July 2004 to August 2006. Preoperative therapy: Five patients underwent initial stent placement in preparation for neoadjuvant therapy. Dysphagia relief was seen in 100% of patients, with optimal caloric needs taken within 24 h of placement. All patients tolerated neoadjuvant therapy without delay from dehydration or malnutrition. One stent migration was found at the time of operation, which was removed without sequelae. Perioperative therapy: Five patients developed delayed (>10 days) esophageal leaks that were managed with removable esophageal stent and percutaneous drainage (in three patients). All patients had successful exclusion of the leak on the day of the procedure with resumption of oral intake on the evening of procedure. All five healed leaks without sequelae. Postoperative therapy: Five patients developed postoperative anastomotic strictures that required dilation and placement of removable esophageal stent. The median number of dilations was 1 (range 1-2), with all stents placed for approximate 3 months duration. All patients had immediate dysphagia relief after stent placement. Removable esophageal stents are novel treatment option to optimize

  20. SPOT-A SENSOR PLACEMENT OPTIMIZATION TOOL FOR ...

    EPA Pesticide Factsheets

    journal article This paper presents SPOT, a Sensor Placement Optimization Tool. SPOT provides a toolkit that facilitates research in sensor placement optimization and enables the practical application of sensor placement solvers to real-world CWS design applications. This paper provides an overview of SPOT’s key features, and then illustrates how this tool can be flexibly applied to solve a variety of different types of sensor placement problems.

  1. Protective tubes for sodium heated water tubes

    DOEpatents

    Essebaggers, Jan

    1979-01-01

    A heat exchanger in which water tubes are heated by liquid sodium which minimizes the results of accidental contact between the water and the sodium caused by failure of one or more of the water tubes. A cylindrical protective tube envelopes each water tube and the sodium flows axially in the annular spaces between the protective tubes and the water tubes.

  2. Risk factors and molecular epidemiology of extended-spectrum β-lactamase-producing Klebsiella pneumoniae in Xiamen, China.

    PubMed

    Deng, Jie; Li, Yan-Ting; Shen, Xu; Yu, Yi-Wen; Lin, Hui-Ling; Zhao, Qi-Feng; Yang, Tian-Ci; Li, Shu-Lian; Niu, Jian-Jun

    2017-12-01

    The aim of this study was to evaluate the risk factors for pneumonia due to extended-spectrum β-lactamase-producing Klebsiella pneumoniae (ESBL-KP) and to analyse the molecular epidemiology of ESBL-KP in Xiamen, China. A case-control study was conducted at Zhongshan Hospital from January 2014 to August 2015. Medical records of patients with nosocomial pneumonia caused by K. pneumoniae were collected. A total of 40 cases with ESBL-KP infection and 90 controls with non-ESBL-KP infection were included. The sequence types (STs) of the 40 ESBL-KP strains were determined by multilocus sequence typing (MLST). Univariate analysis primarily revealed an association between the following seven risk factors and ESBL-KP infection (P<0.10): length of hospitalisation; use of cephalosporins; use of quinolones; presence of a nasogastric tube; presence of an intravenous catheter; mechanical ventilation; and cerebrospinal fluid drainage. Furthermore, multivariate analysis revealed that use of cephalosporins and presence of a nasogastric tube were independent risk factors for ESBL-KP infection (P<0.05), with adjusted odds ratios of 3.473 [95% confidence interval (CI) 1.105-10.911; P=0.033] and 2.488 (95% CI 1.083-5.715; P=0.032), respectively. MLST identified 28 STs. The main STs were ST23 (10.0%) and ST37 (10.0%); three novel STs were identified. Use of cephalosporins and presence of a nasogastric tube are independent risk factors for ESBL-KP infection. In addition, the discovery of three novel STs serves as a reminder to continuously monitor outbreaks of ESBL-KP infection. Copyright © 2017. Published by Elsevier Ltd.

  3. Pharmacokinetic Profiles of Ticagrelor Orodispersible Tablets in Healthy Western and Japanese Subjects.

    PubMed

    Teng, Renli; Hammarberg, Maria; Carlson, Glenn F; Bokelund-Singh, Sara; Ruderfelt, Terese; Blychert, Eva

    2017-11-01

    Ticagrelor is an antiplatelet agent for patients with acute coronary syndrome or a history of myocardial infarction. Two studies compared pharmacokinetic profiles of orodispersible (OD) ticagrelor tablets versus immediate-release (IR) tablets in Western and Japanese subjects. Both studies were open-label, randomized, crossover, single-center trials. Thirty-six healthy subjects (94% white, 6% other race; Western study NCT02400333) and 42 Japanese healthy subjects (Japanese study NCT02436577) received a single 90-mg ticagrelor dose as an OD tablet [with/without water, and via a nasogastric tube (Western study only)], and an IR tablet; washout between treatments was ≥7 days. Assessments included ticagrelor and AR-C124910XX (active metabolite) plasma concentrations for pharmacokinetic analyses, and safety evaluations. In the Western study, the 90% confidence intervals (CIs) of the geometric mean ratios (GMRs) for ticagrelor and AR-C124910XX maximum plasma concentration (C max ) and area under the plasma concentration-time curve (AUC) were within the acceptance interval (80%-125%) for OD tablets (with/without water, via a nasogastric tube) versus the IR tablet; except for an ~15% lowering of ticagrelor C max (90% CI: 76.77%-93.78%) for the OD tablet taken with water. In the Japanese study, 90% CIs of the GMRs for AUC and C max of both ticagrelor and AR-C124910XX were all within the acceptance intervals for the OD (with/without water) versus IR tablet. No new safety issues were identified. Ticagrelor administered as an OD tablet to Western (without water, and via a nasogastric tube) and Japanese (with/without water) subjects was bioequivalent to the IR tablet.

  4. Bioequivalence among three methods of administering pantoprazole granules in healthy subjects.

    PubMed

    Tammara, Brinda; Weisel, Kathy; Katz, Arie; Meng, Xu

    2009-11-01

    The bioequivalence among three methods of administering pantoprazole granules was studied in healthy subjects. In this randomized, open-label, three-period, crossover study, 25 healthy adults received a single 40-mg dose of pantoprazole granules with applesauce orally, with apple juice orally, and with apple juice administered via a nasogastric tube. Subjects were randomly assigned to one of six treatment sequences. Blood samples were collected within 2 hours before treatment administration on study day 1 and at 0.33, 0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, and 24 hours after treatment administration. Plasma pantoprazole concentrations were analyzed by a validated liquid chromatography-tandem mass spectrometry method. The plasma pantoprazole concentration-time data for each subject were analyzed using noncompartmental methods. The 90% confidence intervals (CIs) for the test:reference geometric mean ratio were calculated for the peak pantoprazole concentration (C(max) ) and area under the concentration-time curve (AUC). Of the 25 subjects enrolled, 100% completed the study. The mean C(max) and AUC values were similar for the three administration methods. The 90% CIs for the ratios of the geometric means of the granules in apple juice orally (92.4-112.5%) and in apple juice administered through a nasogastric tube (102.7-125.2%), relative to the granules administered with applesauce orally, were essentially within the bioequivalent limits of 80-125%. No serious adverse events or study discontinuations occurred. Three methods of administering pantoprazole delayed-release granules for oral suspension-with apple juice orally, with applesauce orally, and with apple juice through a nasogastric tube--were bioequivalent in healthy subjects.

  5. Standard Transistor Array (STAR). Volume 1: Placement technique

    NASA Technical Reports Server (NTRS)

    Cox, G. W.; Caroll, B. D.

    1979-01-01

    A large scale integration (LSI) technology, the standard transistor array uses a prefabricated understructure of transistors and a comprehensive library of digital logic cells to allow efficient fabrication of semicustom digital LSI circuits. The cell placement technique for this technology involves formation of a one dimensional cell layout and "folding" of the one dimensional placement onto the chip. It was found that, by use of various folding methods, high quality chip layouts can be achieved. Methods developed to measure of the "goodness" of the generated placements include efficient means for estimating channel usage requirements and for via counting. The placement and rating techniques were incorporated into a placement program (CAPSTAR). By means of repetitive use of the folding methods and simple placement improvement strategies, this program provides near optimum placements in a reasonable amount of time. The program was tested on several typical LSI circuits to provide performance comparisons both with respect to input parameters and with respect to the performance of other placement techniques. The results of this testing indicate that near optimum placements can be achieved by use of the procedures incurring severe time penalties.

  6. [Intraoperative placement of transnasal small intestinal feeding tube during the surgery in 5 cases with high position intestinal obstruction and postoperative feeding].

    PubMed

    Duan, Guang-qi; Zhang, Min; Guan, Xiao-hao; Yin, Zhi-qing

    2012-09-01

    To explore the value of employing the small intestinal feeding tube in treating high position intestinal obstruction of newborn infant. Five newborn infants (3 males and 2 females; 1 premature infant and 4 fully-mature infants; 2 had membranous atresia of duodenum, 1 had annular pancreas, and 2 had proximal small intestine atresia; 1 infant had malrotation). The duodenal membrane-like atresia and the blind-end of small intestine were removed and intestinal anastomosis was performed, which was combined with intestinal malrotation removal. Before the intestinal anastomosis surgery, the anesthetist inserted via nose a 6Fr small intestinal ED tube, made by CREATE MEDIC CO LTD of Japan[ the State Food and Drug Administration-instrument (Im.) 2007-NO.2661620]. Twenty-four hours after surgery, abdominal X-ray plain film was taken and patients were fed with syrup; 48 hours later, formula milk was pumped or lactose-free milk amino acids were given by intravenous injection pump through the feeding tube. The amount of milk and fluids was gradually increased to normal amount according to the condition. In initial 3 days the intravenous nutrition was given and one week after operation, the infants were fed through mouth in addition to pumping milk through the tube and stopped infusion. Ten to 22 days after operation, the tube was removed and the infant patients were discharged. All the five infants showed that the feeding through the nutrition tube was accomplished and the time of venous nutrition was reduced and fistula operation was avoided. None of the infants on question was off the tube and no jaundice exacerbation was found and the liver function was also found normal. At the very beginning, the tube was occasionally blocked by milk vale in one infant and after 0.9% sodium chloride solution flushing patency restored. After that, the feeding tube was washed once with warm water after feeding. In one infant vomiting occurred due to enough oral milk. The photograph of upper

  7. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories

    PubMed Central

    Hélie, Sonia; Poirier, Marie-Andrée; Esposito, Tonino; Turcotte, Daniel

    2017-01-01

    Objectives: The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1) to examine trends in placement use and placement stability since the reform and (2) to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform (n = 9620, 8676, 8425). Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results: There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions: The results suggest interesting avenues for policy makers and service providers to improve the

  8. Students' clinical experience on outreach placements.

    PubMed

    Smith, M; Lennon, M A; Robinson, P G

    2010-02-01

    Primary care outreach placements increasingly feature in UK undergraduate dental curricula. The profile of clinical work undertaken on placement may differ from traditional hospital-based programmes and between outreach settings. An appreciation of any differences could inform curriculum development. To compare the profiles of clinical work experienced on a traditional hospital-based programme and outreach placements in different settings. One dental hospital and eight existing primary care block placements in England. Subjects were four cohorts of senior dental students in one UK dental school. Departmental records provided data on students' clinical experience in different settings and their achievement of placement learning objectives. Descriptive statistics for groups were compared. (1) Counts of patients encountered and of clinical procedures completed in the following categories: simple plastic restorations, endodontics, cast restorations, dentures, extractions and children's dentistry. (2) Student perceptions of placement learning reported via Likert scales. Outreach students encountered twice as many patients and typically completed about three times as much clinical work as students in the hospital, e.g. 44 cf 16 simple plastic restorations, seven cf two endodontic procedures. There were variations in profiles by setting. For example, amalgam being more likely to be used on outreach especially in the General Dental Service; more children's dentistry in community services and more extractions in Dental Access Centres. Students reported learning outcomes generally being achieved (average 94%) although with some variation by setting. Dental outreach training greatly increases the quantity of students' clinical experience in everyday dentistry compared to a hospital-based programme. Placements also increase awareness of service delivery and develop clinical skills. There are appreciable variations between outreach settings possibly reflecting their purposes

  9. Feeding outcomes in infants after supraglottoplasty.

    PubMed

    Eustaquio, Marcia; Lee, Erika Nevin; Digoy, G Paul

    2011-11-01

    Review the impact of bilateral supraglottoplasty on feeding and compare the risk of postoperative feeding difficulties between infants with and without additional comorbidities. Case series with chart review. Children's hospital. The medical records of all patients between birth and 12 months of age treated for laryngomalacia with bilateral supraglottoplasty by a single surgeon (GPD) between December 2005 and September 2009 and followed for a minimum of 1 month were reviewed. Infants with significant comorbidities were evaluated separately. Nutritional intake before and after surgery, as well as speech and language pathology reports, was reviewed to qualify any feeding difficulties. Age at the time of surgery, additional surgical interventions, medical comorbidities, and length of follow-up were also noted during chart review. Of 81 infants who underwent bilateral supraglottoplasty, 75 were eligible for this review. In the cohort of infants without comorbidities, 46 of 48 (96%) had no change or an improvement in their oral intake after surgery. Of the 2 patients with initial worsening of feeding, all resumed oral intake within 2 months. In the group of patients with additional medical comorbidities, 22% required further interventions such as nasogastric tube, dietary modification, or gastrostomy tube placement. Supraglottoplasty in infants has a low incidence of persistent postoperative dysphagia. Infants with additional comorbidities are at a higher risk of feeding difficulty than otherwise healthy infants.

  10. Network placement optimization for large-scale distributed system

    NASA Astrophysics Data System (ADS)

    Ren, Yu; Liu, Fangfang; Fu, Yunxia; Zhou, Zheng

    2018-01-01

    The network geometry strongly influences the performance of the distributed system, i.e., the coverage capability, measurement accuracy and overall cost. Therefore the network placement optimization represents an urgent issue in the distributed measurement, even in large-scale metrology. This paper presents an effective computer-assisted network placement optimization procedure for the large-scale distributed system and illustrates it with the example of the multi-tracker system. To get an optimal placement, the coverage capability and the coordinate uncertainty of the network are quantified. Then a placement optimization objective function is developed in terms of coverage capabilities, measurement accuracy and overall cost. And a novel grid-based encoding approach for Genetic algorithm is proposed. So the network placement is optimized by a global rough search and a local detailed search. Its obvious advantage is that there is no need for a specific initial placement. At last, a specific application illustrates this placement optimization procedure can simulate the measurement results of a specific network and design the optimal placement efficiently.

  11. Humanitarian Engineering Placements in Our Own Communities

    ERIC Educational Resources Information Center

    VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.

    2010-01-01

    There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be…

  12. Mathematics Placement at the University of Illinois

    ERIC Educational Resources Information Center

    Ahlgren Reddy, Alison; Harper, Marc

    2013-01-01

    Data from the ALEKS-based placement program at the University of Illinois is presented visually in several ways. The placement exam (an ALEKS assessment) contains precise item-specific information and the data show many interesting properties of the student populations of the placement courses, which include Precalculus, Calculus, and Business…

  13. Product placement of computer games in cyberspace.

    PubMed

    Yang, Heng-Li; Wang, Cheng-Shu

    2008-08-01

    Computer games are considered an emerging media and are even regarded as an advertising channel. By a three-phase experiment, this study investigated the advertising effectiveness of computer games for different product placement forms, product types, and their combinations. As the statistical results revealed, computer games are appropriate for placement advertising. Additionally, different product types and placement forms produced different advertising effectiveness. Optimum combinations of product types and placement forms existed. An advertisement design model is proposed for use in game design environments. Some suggestions are given for advertisers and game companies respectively.

  14. Automated fiber placement: Evolution and current demonstrations

    NASA Technical Reports Server (NTRS)

    Grant, Carroll G.; Benson, Vernon M.

    1993-01-01

    The automated fiber placement process has been in development at Hercules since 1980. Fiber placement is being developed specifically for aircraft and other high performance structural applications. Several major milestones have been achieved during process development. These milestones are discussed in this paper. The automated fiber placement process is currently being demonstrated on the NASA ACT program. All demonstration projects to date have focused on fiber placement of transport aircraft fuselage structures. Hercules has worked closely with Boeing and Douglas on these demonstration projects. This paper gives a description of demonstration projects and results achieved.

  15. Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.

    PubMed

    Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe

    2014-09-01

    The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.

  16. Jejunal feeding tubes can be efficiently and independently placed by intensive care unit teams.

    PubMed

    Welpe, Pascal; Frutiger, Adrian; Vanek, Patrik; Kleger, Gian-Reto

    2010-01-01

    Nutrition support is an important therapeutic measure in critically ill patients. Several studies have shown that the enteral route is preferable to the parenteral route. Insertion of a feeding tube beyond the ligament of Treitz combined with continuous gastric drainage will reduce regurgitation and probably also the rate of nosocomial pneumonia. This study was conducted to assess the safety, success rate, and time required to establish jejunal nutrition by the fluoroscopy-guided technique in intensive care unit (ICU) patients. This was a prospective observational study in the ICUs of a 300-bed and a 600-bed community hospital. Indications were large gastric residuals during attempted gastric feeding, severe acute pancreatitis, or recurrent aspiration. Feeding tubes were introduced by the ICU staff at bedside under fluoroscopic guidance (a senior ICU physician and a resident or a registered ICU nurse). The correct jejunal position was documented by the application of a radiopaque contrast medium through the tube. After confirmation of the correct position, jejunal tube feeding was immediately started. The insertion procedure in 38 patients lasted a median of 17 minutes. The median time from decision to place the tube until start of enteral feeding was 141 minutes. The success rate was 84.2%. No adverse events were observed. Fluoroscopic placement of a jejunal feeding tube at the bedside is fast, is safe, and has a high success rate when performed by well-trained ICU staff. Using this method makes the ICU team more self-sufficient when critically ill patients require enteral nutrition and no gastroenterologist is available.

  17. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    PubMed

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  18. The evaluation of energy efficiency of convective heat transfer surfaces in tube bundles

    NASA Astrophysics Data System (ADS)

    Grigoriev, B. A.; Pronin, V. A.; Salohin, V. I.; Sidenkov, D. V.

    2017-11-01

    When evaluating the effectiveness of the heat exchange surfaces in the main considered characteristics such as heat flow (Q, Watt), the power required for pumps (N, Watt), and surface area of heat transfer (F, m2). The most correct comparison provides a comparison “ceteris paribus”. Carried out performance comparison “ceteris paribus” in-line and staggered configurations of bundles with a circular pipes can serve as a basis for the development of physical models of flow and heat transfer in tube bundles with tubes of other geometric shapes, considering intertubular stream with attached eddies. The effect of longitudinal and transverse steps of the pipes on the energy efficiency of different configurations would take into account by mean of physical relations between the structure of shell side flow with attached eddies and intensity of transfer processes of heat and momentum. With the aim of energy-efficient placement of tubes, such an approach opens up great opportunities for the synthesis of a plurality of tubular heat exchange surfaces, in particular, the layout of the twisted and in-line-diffuser type with a drop-shaped pipes.

  19. Hannah's Feeding Journey: A Multidisciplinary Treatment Approach to Establishing Oral Acceptance for a Toddler with a Complex Medical History

    ERIC Educational Resources Information Center

    Dunn, Dena M.; Galbally, Sandra Lynn; Markowitz, Goldie; Pucci, Kristy N.; Brochi, Ligia; Cohen, Sherri Shubin

    2017-01-01

    This article presents the importance of multidisciplinary, family-centered care, and a developmental bio-psycho-social approach to treating feeding difficulties in a child with a complex medical history. Hannah spent the first 9 months of her life in the hospital and was discharged dependent on nasogastric tube feeding. Her journey to recovery…

  20. Angioplasty and stent placement - carotid artery

    MedlinePlus

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  1. Randomized clinical trial of pigtail catheter versus chest tube in injured patients with uncomplicated traumatic pneumothorax.

    PubMed

    Kulvatunyou, N; Erickson, L; Vijayasekaran, A; Gries, L; Joseph, B; Friese, R F; O'Keeffe, T; Tang, A L; Wynne, J L; Rhee, P

    2014-01-01

    Small pigtail catheters appear to work as well as the traditional large-bore chest tubes in patients with traumatic pneumothorax, but it is not known whether the smaller pigtail catheters are associated with less tube-site pain. This study was conducted to compare tube-site pain following pigtail catheter or chest tube insertion in patients with uncomplicated traumatic pneumothorax. This prospective randomized trial compared 14-Fr pigtail catheters and 28-Fr chest tubes in patients with traumatic pneumothorax presenting to a level I trauma centre from July 2010 to February 2012. Patients who required emergency tube placement, those who refused and those who could not respond to pain assessment were excluded. Primary outcomes were tube-site pain, as assessed by a numerical rating scale, and total pain medication use. Secondary outcomes included the success rate of pneumothorax resolution and insertion-related complications. Forty patients were enrolled. Baseline characteristics of 20 patients in the pigtail catheter group were similar to those of 20 patients in the chest tube group. No patient had a flail chest or haemothorax. Pain scores related to chest wall trauma were similar in the two groups. Patients with a pigtail catheter had significantly lower mean(s.d.) tube-site pain scores than those with a chest tube, at baseline after tube insertion (3.2(0.6) versus 7.7(0.6); P < 0.001), on day 1 (1.9(0.5) versus 6.2(0.7); P < 0.001) and day 2 (2.1(1.1) versus 5.5(1.0); P = 0.040). The decreased use of pain medication associated with pigtail catheter was not significantly different. The duration of tube insertion, success rate and insertion-related complications were all similar in the two groups. For patients with a simple, uncomplicated traumatic pneumothorax, use of a 14-Fr pigtail catheter is associated with reduced pain at the site of insertion, with no other clinically important differences noted compared with chest tubes. NCT01537289 (http

  2. Mathematics Placement at Cottey College.

    ERIC Educational Resources Information Center

    Callahan, Susan

    In response to the large numbers of students who were failing or dropping out of basic algebra and calculus classes, Cottey College, in Missouri, developed a math placement program in 1982 using Basic Algebra (BA) and Calculus Readiness (CR) tests from the Mathematical Association of America's Placement Testing Program. Cut off scores for the…

  3. CT-guided thermocouple placement for hyperthermia treatment.

    PubMed

    Banerian, K G; Roberts, J L; Borrego, J C; Martinez, A

    1990-05-01

    There is a well-documented synergistic cytotoxic effect when heat is combined with ionizing radiation. An integral component of hyperthermia treatments is the placement of thermocouple probes used for thermal dosimetry. With the surge in interest in the clinical use of hyperthermia, our department is performing an increasing number of thermocouple placements under computed tomographic (CT) guidance. We describe our technique for CT-guided thermocouple placement with two different systems: a trocar introduction system and a peel-away needle introduction system. We discuss the rationale for thermocouple placement, our early experience with this technique, and some potential complications.

  4. Tube support

    DOEpatents

    Mullinax, Jerry L.

    1988-01-01

    A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.

  5. Tapered pulse tube for pulse tube refrigerators

    DOEpatents

    Swift, Gregory W.; Olson, Jeffrey R.

    1999-01-01

    Thermal insulation of the pulse tube in a pulse-tube refrigerator is maintained by optimally varying the radius of the pulse tube to suppress convective heat loss from mass flux streaming in the pulse tube. A simple cone with an optimum taper angle will often provide sufficient improvement. Alternatively, the pulse tube radius r as a function of axial position x can be shaped with r(x) such that streaming is optimally suppressed at each x.

  6. TUBE TESTER

    DOEpatents

    Gittings, H.T. Jr.; Kalbach, J.F.

    1958-01-14

    This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.

  7. A Cognitive Model of College Mathematics Placement

    DTIC Science & Technology

    1989-08-01

    study focused on the precalculus -- calculus placement decision. The Cognitive model uses novel, or analysis level, placement test items in an attempt to...relative to the requirements of a precalculus course. Placement test scores may be partitioned to give analysis and non-analysis subtest scores which can...67 5.1.1 1989 Intercorrelations ....................................................................... 67 5.1.2 1989 Precalculus -Calculus

  8. Strategies for Controlled Placement of Nanoscale Building Blocks

    PubMed Central

    2007-01-01

    The capability of placing individual nanoscale building blocks on exact substrate locations in a controlled manner is one of the key requirements to realize future electronic, optical, and magnetic devices and sensors that are composed of such blocks. This article reviews some important advances in the strategies for controlled placement of nanoscale building blocks. In particular, we will overview template assisted placement that utilizes physical, molecular, or electrostatic templates, DNA-programmed assembly, placement using dielectrophoresis, approaches for non-close-packed assembly of spherical particles, and recent development of focused placement schemes including electrostatic funneling, focused placement via molecular gradient patterns, electrodynamic focusing of charged aerosols, and others. PMID:21794185

  9. Texture control of zircaloy tubing during tube reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagai, N.; Kakuma, T.; Fujita, K.

    1982-01-01

    Seven batches of Zircaloy-2 nuclear fuel cladding tubes with different textures were processed from tube shells of the same size, by different reduction routes, using pilger and 3-roll mills. Based on the texture data of these tubes, the texture control of Zircaloy tubing, the texture gradient across the wall, and the texture change during annealing were studied. The deformation texture of Zicaloy-2 tubing was dependent on the tool's curvature and was independent of the dimensions of the mother tubes. The different slopes of texture gradients were observed between the tubing of higher strain ration and that of lower strain ratio.

  10. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage.

    PubMed

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at -20 cm H2O for 30 min. When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, P<0.001). By 30 min, the split drain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications.

  11. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage

    PubMed Central

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Objective Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. Description We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. Methods After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at −20 cm H2O for 30 min. Results When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, P<0.001). By 30 min, the split drain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. Conclusion The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications. PMID:25478289

  12. Single Port Laparoscopic Gastrostomy: description of a technique and initial experience.

    PubMed

    Palermo, Mariano; Domínguez, Mario Luis; Acquafresca, Pablo; Duza, Guillermo; Giménez, Mariano

    2015-12-01

    Since the first classic descriptions of surgical gastrostomies for feeding by supra-umbilical medial incisions, patients were operated under general anesthesia, with prolonged time of surgery; these were patients in poor health status, undernourished due to inadequate intake or to neurological or tumor involvement, with prolonged hospitalization, both for the recovery of the intestinal motility as well as for the recovery of post-surgical wounds. Therefore, we describe a new minimally invasive technique as an alternative to the percutaneous or endoscopic gastrostomy, in patients where we are not allowed to place a nasogastric tube to insufflate the stomach. This is mostly seen in patients with tumors, which cause obstruction. Between July 2012 and June 2013, 8 patients underwent a single port laparoscopic gastrostomy. Five were females, mean age: 77 years (range: 67-87). In all the patients, it was impossible to place a nasogastric tube, due to obstructive tumor. The mean time of the procedure was 45 minutes. Seven patients underwent tolerance of dextrose 10% through the catheter after 12 hours and one 24 hours after the procedures. Enteral feeding was indicated after the dextrose 10% tolerance was performed. No complications related to the procedure were observed. Currently, the gold standard technique to perform a gastrostomy is the percutaneous or endoscopic approach. In patients with head and neck tumors, when it is not possible to insert a nasogastric tube to insufflate the stomach, a laparoscopic gastrostomy would be indicated. We describe a new technique, step by step, to perform less invasive laparoscopic surgery by a single port laparoscopic gastrostomy. The diameter created is the same as the one performed with an open technique, but in this case, with a minimally invasive approach, that allows us to start feeding the patient with a high quality of feeding, because of the wider lumen.

  13. Gastrostomy tube placement - slideshow

    MedlinePlus

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  14. Clinical Outcomes, Efficacy, and Adverse Events in Patients Undergoing Esophageal Stent Placement for Benign Indications: A Large Multicenter Study.

    PubMed

    Suzuki, Takayuki; Siddiqui, Ali; Taylor, Linda J; Cox, Kristen; Hasan, Raza A; Laique, Sobia N; Mathew, Arun; Wrobel, Piotr; Adler, Douglas G

    2016-01-01

    Esophageal stents are commonly used to treat benign esophageal conditions including refractory benign esophageal strictures, anastomotic strictures, fistulae, perforations and anastomotic leaks. Data on outcomes in these settings remain limited. We performed a retrospective multicenter study of patients who underwent fully or partially covered self-expandable stent placement for benign esophageal diseases. Esophageal stent placements were performed for the following indications: (1) benign refractory esophageal strictures, (2) surgical anastomotic strictures, (3) esophageal perforations, (4) esophageal fistulae, and (5) surgical anastomotic leaks. A total of 70 patients underwent esophageal stent placement for benign esophageal conditions. A total of 114 separate procedures were performed. The most common indication for esophageal stent placement was refractory benign esophageal stricture (48.2%). Global treatment success rate was 55.7%. Treatment success rate was 33.3% in refractory benign strictures, 23.1% in anastomotic strictures, 100% in perforations, 71.4% in fistulae, and 80% in anastomotic leaks. Stent migration was noted in 28 of 70 patients (40%), most commonly seen in refractory benign strictures. This is one of the largest studies to date of esophageal stents to treat benign esophageal diseases. Success rates are lowest in benign esophageal strictures. These patients have few other options beyond chronic dilations, feeding tubes, and surgery, and fully covered self-expandable metallic stent give patients a chance to have their problem fixed endoscopically and still eat by mouth. Perforations, fistulas, and leaks respond very well to esophageal stenting, and stenting should be considered as a first-line therapy in these settings.

  15. Artificial Intelligence based technique for BTS placement

    NASA Astrophysics Data System (ADS)

    Alenoghena, C. O.; Emagbetere, J. O.; Aibinu, A. M.

    2013-12-01

    The increase of the base transceiver station (BTS) in most urban areas can be traced to the drive by network providers to meet demand for coverage and capacity. In traditional network planning, the final decision of BTS placement is taken by a team of radio planners, this decision is not fool proof against regulatory requirements. In this paper, an intelligent based algorithm for optimal BTS site placement has been proposed. The proposed technique takes into consideration neighbour and regulation considerations objectively while determining cell site. The application will lead to a quantitatively unbiased evaluated decision making process in BTS placement. An experimental data of a 2km by 3km territory was simulated for testing the new algorithm, results obtained show a 100% performance of the neighbour constrained algorithm in BTS placement optimization. Results on the application of GA with neighbourhood constraint indicate that the choices of location can be unbiased and optimization of facility placement for network design can be carried out.

  16. Dental hygiene student experiences in external placements in Australia.

    PubMed

    Taylor, Jane A; Hayes, Melanie J; Wallace, Linda

    2012-05-01

    While placements in external locations are being increasingly used in dental education globally, few studies have explored the student learning experience at such placements. The purpose of this study was to investigate student experiences while on external placement in a baccalaureate dental hygiene program. A self-reporting questionnaire was distributed to final-year dental hygiene students (n=77) at the University of Newcastle, Australia, in 2010. The questionnaire included questions regarding the type of placement, experiences offered, supervision, resources available, and lasting impressions. Responding students were generally positive about their external placement experience and indicated that the majority of facilities provided them with the opportunity to provide direct patient care and perform clinical tasks typical of a practicing hygienist. However, there was a statistically significant difference in their opinions about discipline-focused and community placements. Students indicated that their external placement experience provided opportunities to learn more about time and patient management, including hands-on experience with specific clinical tasks. Ongoing evaluations are necessary to ensure that external placements meet both student needs and intended learning outcomes within dental hygiene programs.

  17. Payment of Advanced Placement Exam Fees by Virginia Public School Divisions and Its Impact on Advanced Placement Enrollment and Scores

    ERIC Educational Resources Information Center

    Cirillo, Mary Grupe

    2010-01-01

    The purpose of this study was to determine the impact of Virginia school divisions' policy of paying the fee for students to take Advanced Placement exams on Advanced Placement course enrollment, the number of Advanced Placement exams taken by students, the average scores earned and the percent of students earning qualifying scores of 3, 4, or 5…

  18. A linear programming approach for placement of applicants to academic programs.

    PubMed

    Kassa, Biniyam Asmare

    2013-01-01

    This paper reports a linear programming approach for placement of applicants to study programs developed and implemented at the college of Business & Economics, Bahir Dar University, Bahir Dar, Ethiopia. The approach is estimated to significantly streamline the placement decision process at the college by reducing required man hour as well as the time it takes to announce placement decisions. Compared to the previous manual system where only one or two placement criteria were considered, the new approach allows the college's management to easily incorporate additional placement criteria, if needed. Comparison of our approach against manually constructed placement decisions based on actual data for the 2012/13 academic year suggested that about 93 percent of the placements from our model concur with the actual placement decisions. For the remaining 7 percent of placements, however, the actual placements made by the manual system display inconsistencies of decisions judged against the very criteria intended to guide placement decisions by the college's program management office. Overall, the new approach proves to be a significant improvement over the manual system in terms of efficiency of the placement process and the quality of placement decisions.

  19. Brevard District Plan for Placement and Follow-Up.

    ERIC Educational Resources Information Center

    Thomas, Olive W.

    The Brevard District Plan for placement and follow-up is intended for all secondary students, including dropouts, disadvantaged, adult students, and graduates. The areas of placement may be in gainful employment, educational institutions, or a combination of both. The plan specifies procedures for implementing placement and stipulates the type of…

  20. Immediate placement of endosseous implants into the extraction sockets.

    PubMed

    Ebenezer, Vijay; Balakrishnan, K; Asir, R Vigil Dev; Sragunar, Banu

    2015-04-01

    Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.

  1. Field Placement Treatments: A Comparative Study

    ERIC Educational Resources Information Center

    Parkison, Paul T.

    2008-01-01

    Field placement within teacher education represents a topic of interest for all preservice teacher programs. Present research addresses a set of important questions regarding field placement: (1) What pedagogical methodologies facilitate deep learning during field experiences? (2) Is there a significant difference in treatment effect for…

  2. Gastrostomy Tube Feeding in Children With Developmental or Acquired Disorders: A Longitudinal Comparison on Healthcare Provision and Eating Outcomes 4 Years After Gastrostomy.

    PubMed

    Backman, Ellen; Karlsson, Ann-Kristin; Sjögreen, Lotta

    2018-03-30

    Studies on long-term feeding and eating outcomes in children requiring gastrostomy tube feeding (GT) are scarce. The aim of this study was to describe children with developmental or acquired disorders receiving GT and to compare longitudinal eating and feeding outcomes. A secondary aim was to explore healthcare provision related to eating and feeding. This retrospective cohort study reviewed medical records of children in 1 administrative region of Sweden with GT placement between 2005 and 2012. Patient demographics, primary diagnoses, age at GT placement, and professional healthcare contacts prior to and after GT placement were recorded and compared. Feeding and eating outcomes were assessed 4 years after GT placement. The medical records of 51 children, 28 boys and 23 girls, were analyzed and grouped according to "acquired" (n = 13) or "developmental" (n = 38) primary diagnoses. At 4 years after GT placement, 67% were still using GT. Only 6 of 37 (16%) children with developmental disorders transferred to eating all orally, as opposed to 10 of 11 (91%) children with acquired disorders. Children with developmental disorders were younger at the time of GT placement and displayed a longer duration of GT activity when compared with children with acquired disorders. This study demonstrates a clear difference between children with developmental or acquired disorders in duration of GT activity and age at GT placement. The study further shows that healthcare provided to children with GT is in some cases multidisciplinary, but primarily focuses on feeding rather than eating. © 2018 American Society for Parenteral and Enteral Nutrition.

  3. A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement.

    PubMed

    Goethals, Pauwel; Chaobal, Harshu; Reynaerts, Dominiek; Schaner, David

    2014-04-01

    We present a new device for verifying endotracheal tube (ETT) position that uses specialized sensors intended to distinguish anatomical features of the trachea and esophagus. This device has the potential to increase the safety of resuscitation, surgery, and mechanical ventilation and decrease the morbidity, mortality, and health care costs associated with esophageal intubation and unintended extubation by potentially improving the process and maintenance of endotracheal intubation. The device consists of a tactile sensor connected to the airway occlusion cuff of an ETT. It is intended to detect the presence or absence of tracheal rings immediately upon inflation of the airway occlusion cuff. The initial study detailed here verifies that a prototype device can detect contours similar to tracheal rings in a tracheal model.

  4. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    ERIC Educational Resources Information Center

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  5. Alternative Placements in Initial Teacher Education: An Evaluation

    ERIC Educational Resources Information Center

    Purdy, Noel; Gibson, Ken

    2008-01-01

    The paper evaluates a programme of short alternative placements for final-year B.Ed. students in Northern Ireland, which aims to broaden student teachers' experience and develop their transferable skills. The alternative placement programme is set first in an international context of evolving pre-service field placements and then set in a local…

  6. Videolaparoscopic Catheter Placement Reduces Contraindications to Peritoneal Dialysis

    PubMed Central

    Santarelli, Stefano; Zeiler, Matthias; Monteburini, Tania; Agostinelli, Rosa Maria; Marinelli, Rita; Degano, Giorgio; Ceraudo, Emilio

    2013-01-01

    ♦ Background: Videolaparoscopy is considered the reference method for peritoneal catheter placement in patients with previous abdominal surgery. The placement procedure is usually performed with at least two access sites: one for the catheter and the second for the laparoscope. Here, we describe a new one-port laparoscopic procedure that uses only one abdominal access site in patients not eligible for laparotomic catheter placement. ♦ Method: We carried out one-port laparoscopic placement in 21 patients presenting contraindications to blind surgical procedures because of prior abdominal surgery. This technique consists in the creation of a single mini-laparotomy access through which laparoscopic procedures and placement are performed. The catheter, rectified by an introducer, is inserted inside the port. Subsequently, the port is removed, leaving the catheter in pelvic position. The port is reintroduced laterally to the catheter, confirming or correcting its position. Laparotomic placement was performed in a contemporary group of 32 patients without contraindications to blind placement. Complications and long-term catheter outcome in the two groups were evaluated. ♦ Results: Additional interventions during placement were necessary in 12 patients of the laparoscopy group compared with 5 patients of the laparotomy group (p = 0.002). Laparoscopy documented adhesions in 13 patients, with need for adhesiolysis in 6 patients. Each group had 1 intraoperative complication: leakage in the laparoscopy group, and intestinal perforation in the laparotomy group. During the 2-year follow-up period, laparoscopic revisions had to be performed in 6 patients of the laparoscopy group and in 5 patients of the laparotomy group (p = 0.26). The 1-year catheter survival was similar in both groups. Laparoscopy increased by 40% the number of patients eligible to receive peritoneal dialysis. ♦ Conclusions: Videolaparoscopy placement in patients not eligible for blind surgical

  7. PASS--Placement/Advisement for Student Success.

    ERIC Educational Resources Information Center

    Shreve, Chuck; Wildie, Avace

    In 1985-86, Northern Michigan College (NMC) used funds received from the United States Department of Education to develop a system of assessment, advisement, and placement--Placement/Advisement for Student Success (PASS), an integrated system designed to improve student retention. PASS currently consists of three components: summer orientation,…

  8. Immediate placement of endosseous implants into the extraction sockets

    PubMed Central

    Ebenezer, Vijay; Balakrishnan, K.; Asir, R. Vigil Dev; Sragunar, Banu

    2015-01-01

    Implant by definition “means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose.” The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by “why late when it can be done immediately.” There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed. PMID:26015721

  9. How do we facilitate international clinical placements for nursing students: A cross-sectional exploration of the structure, aims and objectives of placements.

    PubMed

    Browne, Caroline A; Fetherston, Catherine M

    2018-07-01

    International clinical placements provide undergraduate students with a unique and complex clinical learning environment, to explore cultural awareness, experience different health care settings and achieve clinical competencies. Higher education institutions need to consider how to structure these placements to ensure appropriate and achievable aims and learning outcomes. In this study we described the structure, aims and learning outcomes associated with international clinical placement opportunities currently undertaken by Australian undergraduate nursing students in the Asia region. Forty eight percent (n = 18) of the institutions invited responded. Eight institutions met the inclusion criteria, one of which offered three placements in the region, resulting in 10 international placements for which data were provided. An online survey tool was used to collect data during August and September 2015 on international clinical placements conducted by the participating universities. Descriptive data on type and numbers of placements is presented, along with results from the content analysis conducted to explore data from open ended questions on learning aims and outcomes. One hundred students undertook 10 International Clinical Placements offered in the Asian region by eight universities. Variations across placements were found in the length of placement, the number of students participating, facilitator to student ratios and assessment techniques used. Five categories related to the aims of the programs were identified: 'becoming culturally aware through immersion', 'working with the community to promote health', 'understanding the role of nursing within the health care setting', 'translating theory into professional clinical practice', and 'developing relationships in international learning environments'. Four categories related to learning outcomes were identified: 'understanding healthcare and determinants of health', 'managing challenges', 'understanding the

  10. Preparing ESP Learners for Workplace Placement

    ERIC Educational Resources Information Center

    Wood, David

    2009-01-01

    Engineering students in North American universities often participate in cooperative education placements in workplaces as part of the requirements for their degrees and professional certification. Students for whom English is an L2 often experience difficulties in these placements due to the fact that while their academic language ability may be…

  11. Handbook for Job Search/Vocational Placement.

    ERIC Educational Resources Information Center

    Rumbaugh, Welcome A.; And Others

    This manual is intended for use by secondary school and two-year college personnel engaged in placement work, career education, and guidance. It contains five sections, nineteen short appendixes, and fifteen brochures and reproducible items. Outlined in the first section are secondary and postsecondary job search and placement concepts and a…

  12. Inferior Vena Cava Filter Placement and Removal

    MedlinePlus

    ... Professions Site Index A-Z Inferior Vena Cava Filter Placement and Removal During Inferior Vena Cava (IVC) ... benefits vs. risks? What is Inferior Vena Cava Filter Placement and Removal? In an inferior vena cava ...

  13. Four Decades of the Advanced Placement Program.

    ERIC Educational Resources Information Center

    Rothschild, Eric

    1999-01-01

    Reports on the history of the Advanced Placement (AP) program, considering such issues as the program's initiation, changes within the program, its various problems, growth in Advanced Placement, and the program's reach overseas. (CMK)

  14. Math Placement in California's Public Schools

    ERIC Educational Resources Information Center

    Gao, Niu; Adan, Sara

    2016-01-01

    Last year, the California Legislature passed a new law--the California Mathematics Placement Act--to address widespread concern over equity in the math placement process. The law is aimed at improving the measurement of student performance in order to move more students successfully through the high school curriculum. In this context, researchers…

  15. Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes.

    PubMed

    Eslami, Yadolla; Mohammadi, Massood; Fakhraie, Ghasem; Zarei, Reza; Moghimi, Sasan

    2014-02-01

    To report the efficacy and safety of Ahmed glaucoma valve (AGV) insertion into the ciliary sulcus in pseudophakic/aphakic patients. A chart review was done on patients with uncontrolled glaucoma, who underwent AGV implantation with tube inserted into the ciliary sulcus. Baseline intraocular pressure (IOP) and number of medications were compared with that of postoperative follow-up visits. Surgical success was defined as last IOP <21 mm Hg and 20% reduction in IOP, without further surgery for complications or glaucoma control, and without loss of light perception. Postoperative complications were recorded. Twenty-three eyes of 23 patients were recruited with the mean follow-up of 9 months (range, 3 to 24 mo). The mean (SD) age of patients was 49.9 (16.9) years (range, 22 to 80 years). The mean (SD) IOP (mm Hg) was reduced from 37.9 (12.4) before surgery to 16.2 (3.6) at the last follow-up visit (P<0.001). The mean (SD) number of medications was reduced from 3.3 (0.9) preoperatively to 1 (1.1) at the last follow-up (P<0.001). Success rate was 18/23 (78.6%). Complications included endophthalmitis in 1 eye, tube exposure in 1 diabetic patient, and vitreous tube occlusion in 1 eye. No case of corneal decompensation or graft failure was seen during follow-up. Ciliary sulcus placement of the tube of AGV effectively reduces IOP and medication use in short term. It has the potential to lower corneal complications of anterior chamber tube insertion and avoids the need for pars plana vitrectomy and tube insertion in patients at higher risk of corneal decompensation.

  16. Conventional tracheal tubes for intubation through the intubating laryngeal mask airway.

    PubMed

    Kundra, Pankaj; Sujata, N; Ravishankar, M

    2005-01-01

    The laryngeal mask airway (LMA)-Fastrach silicone wire-reinforced tracheal tube (FTST) was specially designed for tracheal intubation through the intubating LMA (ILMA). However, conventional tracheal tubes have been successfully used to accomplish tracheal intubation. We designed this study to evaluate the success rate of blind tracheal intubation through the ILMA by using the FTST, the Rusch polyvinyl chloride tube (PVCT), and the Rusch latex armored tube (LAT). One-hundred-fifty healthy adults of ASA physical status I and II who were undergoing elective surgery under general anesthesia were randomly allocated into three groups. FTST (n=50), prewarmed PVCT (n=50), and LAT (n=50) were used for tracheal intubation. Ease of tracheal intubation was assessed by the time taken, the number of attempts, and the number of maneuvers required for success. In addition, numbers of failed intubation attempts and times taken for ILMA removal were also recorded. After surgery, the incidence of trauma, sore throat, and hoarseness was noted. Significantly more frequent success in tracheal intubation was achieved with the PVCT and FTST (96%) compared with the LAT (82%) (P <0.05). Tracheal intubation on the first attempt was similar with the PVCT and FTST (86%) and was significantly more frequent than with the LAT (52%) (P <0.05). Esophageal placement was significantly more frequent with the LAT (29.7%) when compared with the PVCT and FTST (1.8% and 7.4%, respectively) (P <0.05). The authors conclude that a prewarmed PVCT can be used as successfully as the FTST for blind tracheal intubation through the ILMA, whereas the LAT is associated with more frequent failure and esophageal intubation.

  17. Social media and the intrauterine device: a YouTube content analysis.

    PubMed

    Nguyen, Brian T; Allen, Allison J

    2018-01-01

    YouTube's online archive of video testimonials related to health information are more commonly viewed than those developed by clinicians and professional groups, suggesting the importance of the patient experience to viewers. We specifically sought to examine the accuracy of information on, and projected acceptability of, the intrauterine device (IUD) from these YouTube testimonials. We searched YouTube for videos about individual uploaders' IUD experiences, using the search terms 'intrauterine device', 'IUD', 'Mirena' and 'Paragard'. Given interest in user testimonials, we excluded professional and instructional videos belonging to commercial or non-profit entities. Two reviewers independently analysed the videos using a structured guide, with attention to inaccurate information. Of 86 identified videos, four videos featured clinicians and were excluded; 62 met inclusion criteria. Interrater agreement on IUD portrayal was good (K=0.73). Young (mean age 25, range 19-38, years), white (75%), nulliparous (61%) women primarily uploaded content. Most described placement of the LNG-IUS (65%), were posted within 1 month of insertion (45%), and mentioned side effects (66%) - bleeding, pain, and partner sensation of the strings. About one-third of videos contained inaccurate information (34%) and were thought to project an overall negative experience (30%). Videos portraying IUDs negatively were associated with inaccurate information and/or mention of side effects. While one-third of IUD user testimonials on YouTube contained inaccurate information, the majority of IUD experiences were perceived by our study viewers to be positive. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Utility of Adjunctive Procedures With Balloon Dilation of the Eustachian Tube.

    PubMed

    Ashry, Yehia; Kawai, Kosuke; Poe, Dennis

    2017-12-01

    To assess the role and effect of concomitant adjunctive procedures when combined with balloon dilation of the Eustachian tube (BDET), including a new technique for treating obstructive disease within the bony Eustachian tube (ET). Retrospective case series. Tertiary medical center. Adults with persistent (≥2 years): 1) OME or non-fixed TM retraction AND type B or C tympanogram OR 2) Consistent symptoms of barochallenge with flights or diving, all despite medical treatment for ≥6 weeks. Balloon dilation of the cartilaginous ET (BDET) was performed under general anesthesia using concomitant myringotomy with or without tube placement if indicated. Adjunctive turbinectomy, adenoidectomy, and/or tympanoplasty were used in selected cases. For suspected disease in the bony ET, an illuminated guidewire was used for probing and clearing the lumen. Outcome measures were tympanogram, otomicroscopy, ET mucosal inflammation score, Valsalva maneuver, and PTA audiometry. 67 ETs (48 patients) underwent BDET: 1) 30/67 balloon w/wo myringotomy, w/wo tube, 2) 20/67 plus adjunctive procedure or 3) 17/67 plus guidewire. Follow-up was ranging from 0.4 to 3.4 years (mean 1.3 year, SD = 0.7). Significant improvement occurred in 79%. There was no significant difference in the failure rate comparing balloon dilation with adjunctive procedures 5/20 (25%) or without adjunctive procedures; 4/30 p  = 0.45 (13%). Failure rate for BDET plus guide wire was 5/17 (29%) and resistance within the bony ET occurred in 8/17 (47%). Balloon dilation of the cartilaginous ET demonstrated significant improvement despite expansion of indications that necessitated the addition of adjunctive procedures. 4.

  19. Utility of Adjunctive Procedures With Balloon Dilation of the Eustachian Tube

    PubMed Central

    Ashry, Yehia; Kawai, Kosuke

    2017-01-01

    Objective To assess the role and effect of concomitant adjunctive procedures when combined with balloon dilation of the Eustachian tube (BDET), including a new technique for treating obstructive disease within the bony Eustachian tube (ET). Study Design Retrospective case series. Setting Tertiary medical center. Subjects Adults with persistent (≥2 years): 1) OME or non‐fixed TM retraction AND type B or C tympanogram OR 2) Consistent symptoms of barochallenge with flights or diving, all despite medical treatment for ≥6 weeks. Methods Balloon dilation of the cartilaginous ET (BDET) was performed under general anesthesia using concomitant myringotomy with or without tube placement if indicated. Adjunctive turbinectomy, adenoidectomy, and/or tympanoplasty were used in selected cases. For suspected disease in the bony ET, an illuminated guidewire was used for probing and clearing the lumen. Outcome measures were tympanogram, otomicroscopy, ET mucosal inflammation score, Valsalva maneuver, and PTA audiometry. Results 67 ETs (48 patients) underwent BDET: 1) 30/67 balloon w/wo myringotomy, w/wo tube, 2) 20/67 plus adjunctive procedure or 3) 17/67 plus guidewire. Follow‐up was ranging from 0.4 to 3.4 years (mean 1.3 year, SD = 0.7). Significant improvement occurred in 79%. There was no significant difference in the failure rate comparing balloon dilation with adjunctive procedures 5/20 (25%) or without adjunctive procedures; 4/30 p = 0.45 (13%). Failure rate for BDET plus guide wire was 5/17 (29%) and resistance within the bony ET occurred in 8/17 (47%). Conclusion Balloon dilation of the cartilaginous ET demonstrated significant improvement despite expansion of indications that necessitated the addition of adjunctive procedures. Level of Evidence 4 PMID:29299505

  20. Fiducial Marker Placement

    MedlinePlus

    ... such as stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) , or proton therapy . Fiducial markers are small ... Proton Therapy Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT) Images related to Fiducial Marker Placement Sponsored ...

  1. Gastric residual volume (GRV) and gastric contents measurement by refractometry.

    PubMed

    Chang, Wei-Kuo; McClave, Stephen A; Hsieh, Chung-Bao; Chao, You-Chen

    2007-01-01

    Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion vs delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.

  2. 32 CFR 1656.10 - Job placement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Job placement. 1656.10 Section 1656.10 National....10 Job placement. (a) Selective Service will maintain a job bank for the exclusive purpose of placing ASWs in alternative service jobs. (b) An ASW who has identified his own job in accordance with § 1656.5...

  3. 32 CFR 1656.10 - Job placement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Job placement. 1656.10 Section 1656.10 National....10 Job placement. (a) Selective Service will maintain a job bank for the exclusive purpose of placing ASWs in alternative service jobs. (b) An ASW who has identified his own job in accordance with § 1656.5...

  4. 32 CFR 1656.10 - Job placement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Job placement. 1656.10 Section 1656.10 National....10 Job placement. (a) Selective Service will maintain a job bank for the exclusive purpose of placing ASWs in alternative service jobs. (b) An ASW who has identified his own job in accordance with § 1656.5...

  5. 32 CFR 1656.10 - Job placement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Job placement. 1656.10 Section 1656.10 National....10 Job placement. (a) Selective Service will maintain a job bank for the exclusive purpose of placing ASWs in alternative service jobs. (b) An ASW who has identified his own job in accordance with § 1656.5...

  6. 32 CFR 1656.10 - Job placement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Job placement. 1656.10 Section 1656.10 National....10 Job placement. (a) Selective Service will maintain a job bank for the exclusive purpose of placing ASWs in alternative service jobs. (b) An ASW who has identified his own job in accordance with § 1656.5...

  7. Do Work Placements Improve Final Year Academic Performance or Do High-Calibre Students Choose to Do Work Placements?

    ERIC Educational Resources Information Center

    Jones, C. M.; Green, J. P.; Higson, H. E.

    2017-01-01

    This study investigates whether the completion of an optional sandwich work placement enhances student performance in final year examinations. Using Propensity Score Matching, our analysis departs from the literature by controlling for self-selection. Previous studies may have overestimated the impact of sandwich work placements on performance…

  8. An Examination of Perceptions Associated with Enrollment Procedures and Students Placement in Advanced Placement Courses in Northeast Louisiana

    ERIC Educational Resources Information Center

    Vidrine, Brent

    2013-01-01

    The purpose of the study was to investigate participation rates of minorities and economically disadvantaged students in Advanced Placement programs in selected high schools in Northeast Louisiana. Advanced Placement programs in high schools generally promote higher level education courses. The focus of the investigation was perceptions held by…

  9. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  10. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  11. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  12. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  13. K.s. Micro-implant placement guide.

    PubMed

    Sharma, K; Sangwan, A

    2014-09-01

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal spaces, but because their relative positions may be inconsistent in different radio -graphic views, they are not always accurate. K.S. micro implant placement guide suggested in this article is simple design and easy in fabrication, required minimal equipment for fabrication and does not disturb the existing appliance system, clearly located in the radiograph and the mini-screw can be easily inserted through the guide reducing the chance of implant misplacement.

  14. Placement education pedagogy as social participation: what are students really learning?

    PubMed

    Kell, Clare

    2014-03-01

    This paper draws on empirical fieldwork data of naturally occurring UK physiotherapy placement education to make visible how education is actually carried out and suggest what students may be learning through their placement interactions. The data challenge everyone involved in placement education design and practice to consider the values and practices students are learning to perpetuate through placement education experiences. The researcher undertook an ethnomethodologically informed ethnographic observation of naturally occurring physiotherapy placement education in two UK NHS placement sites. This study adopted a social perspective of learning to focus on the minutiae of placement educator, student and patient interaction practices during student-present therapeutic activities. Two days of placement for each of six senior students were densely recorded in real-time focussing specifically on the verbal, kinesics and proxemics-based elements of the participants' interaction practices. Repeated cycles of data analysis suggested consistent practices irrespective of the placement, educators, students or patients. The data suggest that placement education is a powerful situated learning environment in which students see, experience and learn to reproduce the physiotherapy practices valued by the local placement. Consistently, placement educators and students co-produced patient-facing activities as spectacles of physiotherapy-as-science. In each setting, patients were used as person-absent audiovisual teaching aids from which students learnt to make a case for physiotherapy intervention. The paper challenges physiotherapists and other professions using work-placement education to look behind the rhetoric of their placement documentation and explore the reality of students' learning in the field. The UK-based physiotherapy profession may wish to consider further the possible implications of its self-definition as a 'science-based healthcare profession' on its in

  15. Drain site evisceration of fallopian tube, another reason to discourage abdominal drain: report of a case and brief review of literature.

    PubMed

    Saini, Pradeep; Faridi, M S; Agarwal, Nitin; Gupta, Arun; Kaur, Navneet

    2012-04-01

    Placement of a drain following abdominal surgery is common despite a lack of convincing evidence in the current literature to support this practice. The use of intra-abdominal drain is associated with many potential and serious complications. We report a drain site evisceration of the right fallopian tube after the removal of an intra-abdominal drain. The drain was placed in the right iliac fossa in a patient who underwent a lower segment Caesarean section (LSCS) for meconium liquor with fetal distress. The Pfannenstiel incision made for LSCS was reopened and the protruding inflamed fimbrial end of the right fallopian tube was excised. The patient made an uneventful recovery. Routine intra-abdominal prophylactic drain following an abdominal surgery including LSCS should be discouraged.

  16. [Hepaticojejunostomy after pancreatic head resection - technical aspects for reconstruction of small and fragile bile ducts with T-tube drainage].

    PubMed

    Herzog, T; Belyaev, O; Uhl, W; Seelig, M H; Chromik, A

    2012-12-01

    After pancreatic head resection the reconstruction of small and fragile bile ducts is technically demanding, resulting in more postoperative bile leaks. One option for the reconstruction is the placement of a T-tube drainage at the site of the anastomosis. Standard reconstruction after pancreatic head resection was an end-to-side hepaticojejunostomy with PDS 5.0, 15-25 cm distally from the pancreaticojejunostomy. For patients with a small bile duct diameter (≤ 5 mm) or a fragile bile duct wall the reconstruction was performed with PDS 6.0 and a T-tube drainage at the side of the anastomosis. The reconstruction with a T-tube drainage at the site of the anastomosis is technically easy to perform and offers the opportunity for immediate visualisation of the anastomosis in the postoperative period by application of water soluble contrast medium. If a bile leak occurs, biliary deviation through the T-tube drainage can enable a conservative management without revisional laparotomy in selected patients. Whether or not a conservative management of postoperative bile leaks will lead to more bile duct strictures is a subject for further investigations. A T-tube drainage at the site of the anastomosis can probably not prevent postoperative bile leaks from a difficult hepaticojejunostomy, but in selected patients it offers the opportunity for a conservative management resulting in less re-operations. Therefore we recommend the augmentation of a difficult hepaticojejunostomy with a T-tube drainage. Georg Thieme Verlag KG Stuttgart · New York.

  17. Nursing administration of medication via enteral tubes in adults: a systematic review.

    PubMed

    Phillips, Nicole M; Nay, Rhonda

    Enteral tubes are frequently inserted as part of medical treatment in a wide range of patient situations. Patients with an enteral tube are cared for by nurses in a variety of settings, including general and specialised acute care areas, aged care facilities and at home. Regardless of the setting, nurses have the primary responsibility for administering medication through enteral tubes. Medication administration via an enteral tube is a reasonably common nursing intervention that entails a number of skills, including preparing the medication, verifying the tube position, flushing the tube and assessing for potential complications. If medications are not given effectively through an enteral tube, harmful consequences may result leading to increased morbidity, for example, tube occlusion, diarrhoea and aspiration pneumonia. There are resultant costs for the health-care system related to possible increased length of stay and increased use of equipment. Presently what is considered to be best practice to give medications through enteral tubes is unknown. The objective of this systematic review was to determine the best available evidence on which nursing interventions are effective in minimising the complications associated with the administration of medications via enteral tubes in adults. Nursing interventions and considerations related to medication administration included form of medication, verifying tube placement before administration, methods used to give medication, methods used to flush tubes, maintenance of tube patency and specific practices to prevent possible complications related to the administration of enteral medications. The following databases were searched for literature reported in English only: CINAHL, MEDLINE, The Cochrane Library, Current Contents/All Editions, EMBASE, Australasian Medical Index and PsychINFO. There was no date restriction applied. In addition, the reference lists of all included studies were scrutinised for other potentially

  18. Nursing administration of medication via enteral tubes in adults: a systematic review.

    PubMed

    Phillips, Nicole M; Nay, Rhonda

    2007-09-01

    Background  Enteral tubes are frequently inserted as part of medical treatment in a wide range of patient situations. Patients with an enteral tube are cared for by nurses in a variety of settings, including general and specialised acute care areas, aged care facilities and at home. Regardless of the setting, nurses have the primary responsibility for administering medication through enteral tubes. Medication administration via an enteral tube is a reasonably common nursing intervention that entails a number of skills, including preparing the medication, verifying the tube position, flushing the tube and assessing for potential complications. If medications are not given effectively through an enteral tube, harmful consequences may result leading to increased morbidity, for example, tube occlusion, diarrhoea and aspiration pneumonia. There are resultant costs for the health-care system related to possible increased length of stay and increased use of equipment. Presently what is considered to be best practice to give medications through enteral tubes is unknown. Objectives  The objective of this systematic review was to determine the best available evidence on which nursing interventions are effective in minimising the complications associated with the administration of medications via enteral tubes in adults. Nursing interventions and considerations related to medication administration included form of medication, verifying tube placement before administration, methods used to give medication, methods used to flush tubes, maintenance of tube patency and specific practices to prevent possible complications related to the administration of enteral medications. Search strategy  The following databases were searched for literature reported in English only: CINAHL, MEDLINE, The Cochrane Library, Current Contents/All Editions, EMBASE, Australasian Medical Index and PsychINFO. There was no date restriction applied. In addition, the reference lists of all included

  19. Prehospital endotracheal intubation and chest tubing does not prolong the overall resuscitation time of severely injured patients: a retrospective, multicentre study of the Trauma Registry of the German Society of Trauma Surgery.

    PubMed

    Kulla, Martin; Helm, Matthias; Lefering, Rolf; Walcher, Felix

    2012-06-01

    The aim of this study was to determine whether prehospital endotracheal intubation (ETI) and chest tube placement is unnecessarily time consuming in severely injured patients. A retrospective, multicentre study including all adult patients (ISS ≥9; 2002-7) of the Trauma Registry of the German Society of Trauma Surgery who were not secondarily transferred to a trauma centre and received a definitive airway and a chest tube. Creating four groups: AA (n=963) receiving ETI and chest tube on scene, AB (n=1547) ETI performed in the prehospital setting but chest tubing later in the emergency department (ED) and BB (n=640) receiving both procedures in the ED. The BA collective (ETI performed in the ED, but chest tubing on scene) was excluded from the study because of the small sample size (n=41). The trauma resuscitation time (TRT), demographic data, injuries, treatment and outcome of the remaining three collectives were compared. The prehospital TRT of the AA collective was longer than the AB and BB subgroups (80±37 min vs 77±44 min 65±46 min; p<0.01). Although the AA and AB subgroups were more severely injured (ISS 35±15 vs 38±15 vs 31±12; p<0.01) and showed poorer vital parameters on scene, the overall TRT (accident until end of ED treatment) were equal for all three groups (152±59 min vs 151±62 min vs 148±68 min; p=0.07). The TRISS adjusted mortality was also equal in all three groups. In a physician-based emergency medical service, prehospital ETI and chest tube placement do not prolong the total TRT of severely injured patients.

  20. Determination of tube-to-tube support interaction characteristics. [PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haslinger, K.H.

    Tube-to-tube support interaction characteristics were determined on a multi-span tube geometry representative of the hot-leg side of the C-E, System 80 steam generator design. Results will become input for an autoclave type wear test program on steam generator tubes, performed by Kraftwerk Union (KWU). Correlation of test data reported here with similar data obtained from the wear tests will be performed in an attempt to make predictions about the long-term fretting behavior of steam generator tubes.

  1. Transesophageal Echocardiography-Guided Epicardial Left Ventricular Lead Placement by Video-Assisted Thoracoscopic Surgery in Nonresponders to Biventricular Pacing and Previous Chest Surgery.

    PubMed

    Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar

    2018-06-14

    The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.

  2. Alternate tube plugging criteria for steam generator tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cueto-Felgueroso, C.; Aparicio, C.B.

    1997-02-01

    The tubing of the Steam Generators constitutes more than half of the reactor coolant pressure boundary. Specific requirements governing the maintenance of steam generator tubes integrity are set in Plant Technical Specifications and in Section XI of the ASME Boiler and Pressure Vessel Code. The operating experience of Steam Generator tubes of PWR plants has shown the existence of some types of degradatory processes. Every one of these has an specific cause and affects one or more zones of the tubes. In the case of Spanish Power Plants, and depending on the particular Plant considered, they should be mentioned themore » Primary Water Stress Corrosion Cracking (PWSCC) at the roll transition zone (RTZ), the Outside Diameter Stress Corrosion Cracking (ODSCC) at the Tube Support Plate (TSP) intersections and the fretting with the Anti-Vibration Bars (AVBs) or with the Support Plates in the preheater zone. The In-Service Inspections by Eddy Currents constitutes the standard method for assuring the SG tubes integrity and they permit the monitoring of the defects during the service life of the plant. When the degradation reaches a determined limit, called the plugging limit, the SG tube must be either repaired or retired from service by plugging. Customarily, the plugging limit is related to the depth of the defect. Such depth is typically 40% of the wall thickness of the tube and is applicable to any type of defect in the tube. In its origin, that limit was established for tubes thinned by wastage, which was the predominant degradation in the seventies. The application of this criterion for axial crack-like defects, as, for instance, those due to PWSCC in the roll transition zone, has lead to an excessive and unnecessary number of tubes being plugged. This has lead to the development of defect specific plugging criteria. Examples of the application of such criteria are discussed in the article.« less

  3. Advanced tow placement of composite fuselage structure

    NASA Technical Reports Server (NTRS)

    Anderson, Robert L.; Grant, Carroll G.

    1992-01-01

    The Hercules NASA ACT program was established to demonstrate and validate the low cost potential of the automated tow placement process for fabrication of aircraft primary structures. The program is currently being conducted as a cooperative program in collaboration with the Boeing ATCAS Program. The Hercules advanced tow placement process has been in development since 1982 and was developed specifically for composite aircraft structures. The second generation machine, now in operation at Hercules, is a production-ready machine that uses a low cost prepreg tow material form to produce structures with laminate properties equivalent to prepreg tape layup. Current program activities are focused on demonstration of the automated tow placement process for fabrication of subsonic transport aircraft fuselage crown quadrants. We are working with Boeing Commercial Aircraft and Douglas Aircraft during this phase of the program. The Douglas demonstration panels has co-cured skin/stringers, and the Boeing demonstration panel is an intricately bonded part with co-cured skin/stringers and co-bonded frames. Other aircraft structures that were evaluated for the automated tow placement process include engine nacelle components, fuselage pressure bulkheads, and fuselage tail cones. Because of the cylindrical shape of these structures, multiple parts can be fabricated on one two placement tool, thus reducing the cost per pound of the finished part.

  4. Clinical placements in mental health: a literature review.

    PubMed

    Happell, Brenda; Gaskin, Cadeyrn J; Byrne, Louise; Welch, Anthony; Gellion, Stephen

    2015-01-01

    Gaining experience in clinical mental health settings is central to the education of health practitioners. To facilitate the ongoing development of knowledge and practice in this area, we performed a review of the literature on clinical placements in mental health settings. Searches in Academic Search Complete, CINAHL, Medline and PsycINFO databases returned 244 records, of which 36 met the selection criteria for this review. Five additional papers were obtained through scanning the reference lists of those papers included from the initial search. The evidence suggests that clinical placements may have multiple benefits (e.g. improving students' skills, knowledge, attitudes towards people with mental health issues and confidence, as well as reducing their fears and anxieties about working in mental health). The location and structure of placements may affect outcomes, with mental health placements in non-mental health settings appearing to have minimal impact on key outcomes. The availability of clinical placements in mental health settings varies considerably among education providers, with some students completing their training without undertaking such structured clinical experiences. Students have generally reported that their placements in mental health settings have been positive and valuable experiences, but have raised concerns about the amount of support they received from education providers and healthcare staff. Several strategies have been shown to enhance clinical placement experiences (e.g. providing students with adequate preparation in the classroom, implementing learning contracts and providing clinical supervision). Educators and healthcare staff need to work together for the betterment of student learning and the healthcare professions.

  5. Utilisation of the healthcare system for authentic early experience placements.

    PubMed

    Hays, Richard B

    2013-01-01

    Authentic early experience in clinical contexts adds interest and relevance to basic medical education, and is regarded positively by both learners and teachers. However, with the recent expansion of medical education, the healthcare system appears close to reaching its capacity for student supervision. This study explores the utilisation of the healthcare system for early clinical placements. A secondary analysis was conducted of data from the Medical Schools Outcomes Database, collected from the 2010 annual questionnaire, focusing on the timing, duration and location of clinical placements during 2009 within the first half of basic medical education programs in Australia. Data was received for 67% of Australian medical students, reporting a total of 16 812 early clinical placements that occupied 97 319 days of supervised time in a wide variety of hospital, general practice and Indigenous health contexts, both urban and rural, across the Australian healthcare system. These early placements occupied about 16% of total clinical placement time for all students in all training years during 2009. The majority of these placements were for only a few hours or days; exceptions were longitudinal placements in regional and rural communities at a minority of schools. Early clinical placements may pose significant resource costs for placement providers, particularly supervision time and expertise. As medical education expands and the teaching capacity of the Australian healthcare system appears to reach its limits, it may be necessary to allocate placements according to their specific learning outcomes, prioritise more acute settings for more senior students, and increase capacity in less acute health and social care settings.

  6. Modified endotracheal tube: emergency alternative to paediatric tracheostomy tube.

    PubMed

    Kurien, M; Raviraj, R; Mathew, J; Kaliaperumal, I; Ninan, S

    2011-07-01

    In an emergency, the non-availability of a conventional paediatric tracheostomy tube is a therapeutic challenge for the attending surgeon. To describe a simple alternative to a paediatric tracheostomy tube for use in an emergency situation. Case report of a 14-year-old boy who developed tracheomalacia following partial cricotracheal resection for subglottic stenosis. As a suitably sized tracheostomy tube (with a long narrow segment) was not available, an endotracheal tube was modified and used successfully. Details of the modification, and a relevant literature review, are also discussed. In the paediatric age group, when an appropriately sized tracheostomy tube is not available, a modified endotracheal tube is a simple temporary alternative; this may be especially useful in an emergency.

  7. Brand placement and consumer choice: an in-store experiment.

    PubMed

    Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon

    2009-01-01

    An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.

  8. Emergency Shelter Placement of Rural Children: Placement and Discharge Patterns.

    ERIC Educational Resources Information Center

    Van Hook, Mary

    1994-01-01

    Examines patterns associated with placement and subsequent discharge of rural children in emergency shelter care. Suggests that the growing numbers of children being placed out of their homes, runaway adolescents, and homeless children, underscore the importance of identifying children likely to be referred for emergency services, as those…

  9. Is there a difference in outcome when treating traumatic intraperitoneal bladder rupture with or without a suprapubic tube?

    PubMed

    Volpe, M A; Pachter, E M; Scalea, T M; Macchia, R J; Mydlo, J H

    1999-04-01

    Primary bladder repair with a suprapubic tube is considered to be effective for managing intraperitoneal bladder injury. We compared the outcomes of suprapubic tube placement and no suprapubic tube for this injury. We reviewed the charts of 31 men and 3 women with a mean age of 28.5 years who required emergency operative repair without a cystogram of traumatic bladder injury from 1992 to 1997. Patient characteristics, mechanism of injury, associated injuries, and short and long-term complications were reviewed. Penetrating and blunt trauma occurred in 28 (82%) and 5 (15%) patients, respectively, while 1 had spontaneous bladder rupture. After primary bladder repair the bladder was drained with a suprapubic tube in 18 cases (53%) and a urethral catheter only in 16 (47%). There were no significant differences between the 2 groups with respect to mechanism of injury, patient age, location of injury in the bladder, coexisting medical illnesses, stability in the field or emergency room, or the bladder repair technique. The 18 patients treated with a suprapubic tube had an associated injury that resulted in 2 deaths, while 13 of the 16 treated with urethral catheter drainage only had an associated injury and 1 died. Urological and nonurological complications in the suprapubic tube versus urethral catheter only group developed in 28 and 33 versus 19 and 19% of the cases, respectively (p <0.05). Followup ranged from 1 month to 4 years. No significant long-term morbidity was noted in either group. These data indicate that intraperitoneal bladder injuries may be equally well managed by primary bladder repair and urethral catheter drainage only versus suprapubic tube drainage.

  10. BRAND PLACEMENT AND CONSUMER CHOICE: AN IN-STORE EXPERIMENT

    PubMed Central

    Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon

    2009-01-01

    An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior. PMID:20190939

  11. Brand Placement and Consumer Choice: An in-Store Experiment

    ERIC Educational Resources Information Center

    Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon

    2009-01-01

    An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.…

  12. An acoustical guidance and position monitoring system for endotracheal tubes.

    PubMed

    Mansfield, J P; Lyle, R P; Voorhees, W D; Wodicka, G R

    1993-12-01

    A prototype instrument to guide the placement and continuously monitor the position of an endotracheal tube (ETT) was developed. An incident audible sound pulse is introduced into the proximal ETT and detected as it travels down the ETT via a miniature microphone located in the wall. This pulse is then emitted from the tube tip into the airways and the reflected signal from the airways is detected by the microphone. A well defined reflection arises from the point where the total cross sectional area of the airways increases rapidly, and the difference in timing between detection of the incident pulse and this reflection is used to determine ETT position or movement. This reflection is not observed if the ETT is erroneously placed in the esophagus. The amplitude and polarity of an additional reflection that occurs at the ETT tip is used to estimate the cross-sectional area of the airway in which the ETT is placed. This combined information allows discrimination between tracheal and bronchial intubation and can be used to insure an adequate fit between the ETT and trachea. The instrument has proven extremely reliable in multiple intubations in eight canines and offers the potential to noninvasively and inexpensively monitor ETT position in a continuous manner.

  13. Alternative method for predicting optimal insertion depth of the laryngeal tube in children.

    PubMed

    Kim, J T; Jeon, S Y; Kim, C S; Kim, S D; Kim, H S

    2007-11-01

    Little information is available about the accuracy of the teeth mark on the laryngeal tube (LT) as a guide to correct placement in children. The aim of this crossover study was to evaluate three methods for optimal insertion depth of the size (#) 2 tube in children weighing 12-25 kg. In 24 children, the LT #2 was consecutively inserted by three different methods: (A) until the thick teeth mark on the tube was aligned with the upper incisors, (B) until resistance was felt, and (C) by inserting to a depth, previously measured, of the curved distance between the cricoid cartilage and the upper incisor. In each case, the depth of insertion, the degree of effective ventilation, the presence of leakage, and the fibreoptic view were assessed. Insertion based on the teeth mark led to a shorter insertion depth and a greater incidence of inadequate ventilation compared with the other two methods. There was no difference in the adequacy of ventilation between methods B and C. The vocal cords were more easily identified with methods B (62.5%) and C (75%) than with method A (12.5%). Insertion of the LT #2 aligned with the teeth mark can result in a shallow insertion depth and inadequate ventilation. The measured distance from the cricoid cartilage to the upper incisor offers alternative guidance for correct LT insertion.

  14. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  15. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  16. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  17. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  18. Understanding Successful Sandwich Placements: A Bourdieusian Approach

    ERIC Educational Resources Information Center

    Clark, Martyn; Zukas, Miriam

    2016-01-01

    Sandwich placements and other integrated work and study schemes are increasingly advocated as a key means by which universities can promote students' employability. However, there is little understanding of how successful placements work in terms of facilitating learning and development. Drawing on three longitudinal case studies of students who…

  19. Factors influencing radiation therapy student clinical placement satisfaction

    PubMed Central

    Bridge, Pete; Carmichael, Mary-Ann

    2014-01-01

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning. PMID:26229635

  20. Factors influencing radiation therapy student clinical placement satisfaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bridge, Pete; Carmichael, Mary-Ann

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanismsmore » during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning.« less

  1. Private Placement Debt Financing for Public Entities

    ERIC Educational Resources Information Center

    Holman, Lance S.

    2010-01-01

    Private placement financing is a debt or capital lease obligation arranged between a municipality or a 501(c) (3) not-for-profit organization and a single sophisticated institutional investor. The investor can be a bank, insurance company, finance company, hedge fund, or high-net worth individual. Private placement financing is similar to…

  2. Patterns of out-of-home placement decision-making in child welfare.

    PubMed

    Chor, Ka Ho Brian; McClelland, Gary M; Weiner, Dana A; Jordan, Neil; Lyons, John S

    2013-10-01

    Out-of-home placement decision-making in child welfare is founded on the best interest of the child in the least restrictive setting. After a child is removed from home, however, little is known about the mechanism of placement decision-making. This study aims to systematically examine the patterns of out-of-home placement decisions made in a state's child welfare system by comparing two models of placement decision-making: a multidisciplinary team decision-making model and a clinically based decision support algorithm. Based on records of 7816 placement decisions representing 6096 children over a 4-year period, hierarchical log-linear modeling characterized concordance or agreement, and discordance or disagreement when comparing the two models and accounting for age-appropriate placement options. Children aged below 16 had an overall concordance rate of 55.7%, most apparent in the least restrictive (20.4%) and the most restrictive placement (18.4%). Older youth showed greater discordant distributions (62.9%). Log-linear analysis confirmed the overall robustness of concordance (odd ratios [ORs] range: 2.9-442.0), though discordance was most evident from small deviations from the decision support algorithm, such as one-level under-placement in group home (OR=5.3) and one-level over-placement in residential treatment center (OR=4.8). Concordance should be further explored using child-level clinical and placement stability outcomes. Discordance might be explained by dynamic factors such as availability of placements, caregiver preferences, or policy changes and could be justified by positive child-level outcomes. Empirical placement decision-making is critical to a child's journey in child welfare and should be continuously improved to effect positive child welfare outcomes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  4. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  5. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  6. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  7. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  8. Soft-Tissue Grafting Techniques Associated With Immediate Implant Placement.

    PubMed

    Bishara, Mark; Kurtzman, Gregori M; Khan, Waji; Choukroun, Joseph; Miron, Richard J

    2018-02-01

    Immediate implant placement often presents challenges in terms of predictably obtaining soft-tissue coverage over the implant site. While delayed implant placement offers the ability for soft tissues to grow and invade the extraction socket making their attachment around implants more predictable, immediate implant placement poses a significant risk of bacterial invasion towards the implant surface as a result of insignificant soft-tissue volume. Soft-tissue grafting techniques have often been proposed for use during immediate implant placement to augment soft-tissue deficiencies, including the use of either palatal connective tissue grafts (CTGs) or collagen-derived scaffolds. However, both of these approaches have significant drawbacks in that CTGs are harvested with high patient morbidity and collagen scaffolds remain avascular and acelluar posing a risk of infection/implant contamination. More recently, platelet-rich fibrin (PRF) has been proposed as an economical and biological means to speed soft-tissue wound healing. In combination with immediate implant placement, PRF offers an easily procurable low-cost regenerative modality that offers an efficient way to improve soft-tissue attachment around implants. Furthermore, the supra-physiological concentration of defense-fighting leukocytes in PRF, combined with a dense fibrin meshwork, is known to prevent early bacterial contamination of implant surfaces, and the biological concentrations of autologous growth factors in PRF is known to increase tissue regeneration. This article discusses soft-tissue grafting techniques associated with immediate implant placement, presents several cases demonstrating the use of PRF in routine immediate implant placement, and further discusses the biological and economic advantages of PRF for the management of soft-tissue grafting during immediate implant placement.

  9. US Army Medical Department Journal, April-June 2005

    DTIC Science & Technology

    2005-06-01

    systematically assess their practice, and identify Medical Education Directorate and the final link in the medical areas where education can effect...syndrome would nasogastric tube was drained intermittently and otherwise mandate decompressive fasciotomies of the affected extremities vented. Urine...AMEDD Continuum of Medical Education 12 COL John M. Powers, MC, USA The Medical Corps Assignment Process 16 COL Jonathan H. Jaffin, MC, USA, et al

  10. A Proposal for a Study of Bulimia Among Women in the United States Air Force

    DTIC Science & Technology

    1988-12-01

    to be effective (7). Activities on many bases are limitless and frequently include softball, basketball, football, baseball, volleyball, soccer ...34most authorities recognize that the recommended body weight of these tables does not provide an accurate assessment of body fat because of the wide...how many die undiagnosed. Starvation, -uic4 - inadequate potassium intake and stomach perforation from insertion of a nasogastric tube are the more

  11. 33 CFR 183.566 - Fuel pumps: Placement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel pumps: Placement. 183.566...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.566 Fuel pumps: Placement. Each fuel pump must be on the engine it serves or within 12 inches of the engine, unless it is a...

  12. Comprehensive Approach to Pupil Planning: Stage II - Planning and Placement (Includes Planning and Placement Team Meeting Agenda). Experimental Edition.

    ERIC Educational Resources Information Center

    Vlasak, Frances Stetson; Kaufman, Martin J.

    Presented is Stage II of the Comprehensive Approach to Pupil Planning (CAPP) System, a three-stage model for planning educational interventions in the regular and special education classrooms and for guiding placement decisions. The guide focuses on the evaluation services performed by the Planning and Placement Team (PPT) with sections on the…

  13. Dry Ribbon for Heated Head Automated Fiber Placement

    NASA Technical Reports Server (NTRS)

    Hulcher, A. Bruce; Marchello, Joseph M.; Hinkley, Jeffrey A.; Johnston, Norman J.; Lamontia, Mark A.

    2000-01-01

    Ply-by-ply in situ processes involving automated heated head deposition are being developed for fabrication of high performance, high temperature composite structures from low volatile content polymer matrices. This technology requires (1) dry carbon fiber towpreg, (2) consolidation of towpreg to quality, placement-grade unidirectional ribbon or tape, and (3) rapid, in situ, accurate, ply-by-ply robotic placement and consolidation of this material to fabricate a composite structure. In this study, the physical properties of a candidate thermoplastic ribbon, PIXA/IM7, were evaluated and screened for suitability in robotic placement. Specifically, towpreg was prepared from PIXA powder. Various conditions (temperatures) were used to convert the powder-coated towpreg to ribbons with varying degrees of processability. Ribbon within preset specifications was fabricated at 3 temperatures: 390, 400 and 410 C. Ribbon was also produced out-of-spec by purposely overheating the material to a processing temperature of 450 C. Automated placement equipment at Cincinnati Milacron and NASA Langley was used to fabricate laminates from these experimental ribbons. Ribbons were placed at 405 and 450 C by both sets of equipment. Double cantilever beam and wedge peel tests were used to determine the quality of the laminates and, especially, the interlaminar bond formed during the placement process. Ribbon made under conditions expected to be non-optimal (overheated) resulted in poor placeability and composites with weak interlaminar bond strengths, regardless of placement conditions. Ribbon made under conditions expected to be ideal showed good processability and produced well-consolidated laminates. Results were consistent from machine to machine and demonstrated the importance of ribbon quality in heated-head placement of dry material forms. Preliminary screening criteria for the development and evaluation of ribbon from new matrix materials were validated.

  14. The Re-Placement Test: Using TOEFL for Purposes of Placement

    ERIC Educational Resources Information Center

    Moglen, Daniel

    2015-01-01

    This article will consider using TOEFL scores for purposes of placement and advising for international graduate students at a northern California research university. As the number of international students is on the rise and the funds for the graduate ESL program are diminishing, the way in which the university is handling the influx of…

  15. Where Should We Go With Advanced Placement?

    NASA Astrophysics Data System (ADS)

    Lichten, William

    2001-04-01

    This is a review of the Advanced Placement (AP)Program. In disagreement with claims of the College Board, there is firm evidence that the average test performance level has dropped. The College Board's scale and claims for AP qualification disagree seriously with college standards. A majority of tests taken do not qualify. It appears that "advanced placement" is coming closer to "placement." This paper recommends that the College Board's policy, which previously has concentrated on the numbers of participants, should include an emphasis on student performance and program quality. AP could accomplish its goal of reaching a wider range of students by changing along the lines followed in college introductory physics courses: multiple tracks.

  16. An interaction between levodopa and enteral nutrition resulting in neuroleptic malignant-like syndrome and prolonged ICU stay.

    PubMed

    Bonnici, André; Ruiner, Carola-Ellen; St-Laurent, Lyne; Hornstein, David

    2010-09-01

    To describe a probable interaction between enteral feeds and levodopa leading to neuroleptic malignant-like syndrome (NMLS) in a polytrauma patient with Parkinson's disease (PD). A 63-year-old morbidly obese male polytrauma patient with PD and type 2 diabetes mellitus was admitted to our intensive care unit postoperatively. Enteral feeds were administered per nasogastric tube and provided 0.88 g /kg/day of protein based on ideal body weight (IBW). His PD medications (pramipexole, entacapone, and immediate-release levodopa/carbidopa 100 mg/25 mg, 1.5 tablets 4 times daily) were administered via nasogastric tube. To achieve better glycemic control, his enteral feeds were changed to a formula that provided 1.8 g/kg/day of protein based on IBW. In the following 24 hours, the patient's mental status deteriorated and he was reintubated. He developed a high fever (40.5 degrees C), leukocytosis, elevated serum creatine kinase (CK) (480-1801 units/L), and acute renal impairment. His enteral nutrition was changed to decrease protein intake to 1.0 g/kg/day based on IBW and he was given bromocriptine 5 mg 3 times daily via nasogastric tube. Within 24 hours, the patient's mental status improved, his temperature and CK decreased, and his renal function began to improve; the values returned to baseline levels on the 18th day of admission. Withdrawal or dose reduction of levodopa in patients with PD has been reported to precipitate NMLS, which is potentially fatal. Because dietary protein can decrease the absorp0tion of levodopa, a potential for an interaction between levodopa and enteral feedings exists, although published reports of such an interaction are limited. In this patient, the likelihood that a drug-nutrient interaction occurred between levodopa and enteral feedings is considered to be probable based on the Naranjo probability scale and the Horn Drug Interaction Probability Scale. Health-care professionals should be aware of the interaction between levodopa and protein

  17. Laparoscopic versus open repair for perforated peptic ulcer: A meta analysis of randomized controlled trials.

    PubMed

    Tan, Shanjun; Wu, Guohao; Zhuang, Qiulin; Xi, Qiulei; Meng, Qingyang; Jiang, Yi; Han, Yusong; Yu, Chao; Yu, Zhen; Li, Ning

    2016-09-01

    The role of laparoscopic surgery in the repair for peptic ulcer disease is unclear. The present study aimed to compare the safety and efficacy of laparoscopic versus open repair for peptic ulcer disease. Randomized controlled trials (RCTs) comparing laparoscopic versus open repair for peptic ulcer disease were identified from MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and references of identified articles and relevant reviews. Primary outcomes were postoperative complications, mortality, and reoperation. Secondary outcomes were operative time, postoperative pain, postoperative hospital stay, nasogastric tube duration, and time to resume diet. Statistical analysis was carried out by Review Manage software. Five RCTs investigating a total of 549 patients, of whom, 279 received laparoscopic repair and 270 received open repair, were included in the final analysis. There were no significant differences between these two procedures in some primary outcomes including overal postoperative complication rate, mortality, and reoperation rate. Subcategory analysis of postoperative complications showed that laparoscopic repair had also similar rates of repair site leakage, intra-abdominal abscess, postoperative ileus, pneumonia, and urinary tract infection as open surgery, except of the lower surgical site infection rate (P < 0.05). In addition, there were also no significant differences between these two procedures in some second outcomes including operative time, postoperative hospital stay, and time to resume diet, but laparoscopic repair had shorter nasogastric tube duration (P < 0.05) and less postoperative pain (P < 0.05) than open surgery. Laparoscopic surgery is comparable with open surgery in the setting of repair for perforated peptic ulcer. The obvious advantages of laparoscopic surgery are the lower surgical site infection rate, shorter nasogastric tube duration and less postoperative pain. However, more higher quality studies should be

  18. Predictors of professional placement outcome: cultural background, English speaking and international student status.

    PubMed

    Attrill, Stacie; McAllister, Sue; Lincoln, Michelle

    2016-08-01

    Placements provide opportunities for students to develop practice skills in professional settings. Learning in placements may be challenging for culturally and linguistically diverse (CALD) students, international students, or those without sufficient English proficiency for professional practice. This study investigated whether these factors, which are hypothesized to influence acculturation, predict poor placement outcome. Placement outcome data were collected for 854 students who completed 2747 placements. Placement outcome was categorized into 'Pass' or 'At risk' categories. Multilevel binomial regression analysis was used to determine whether being CALD, an international student, speaking 'English as an additional language', or a 'Language other than English at home' predicted placement outcome. In multiple multilevel analysis speaking English as an additional language and being an international student were significant predictors of 'at risk' placements, but other variables tested were not. Effect sizes were small indicating untested factors also influenced placement outcome. These results suggest that students' English as an additional language or international student status influences success in placements. The extent of acculturation may explain the differences in placement outcome for the groups tested. This suggests that learning needs for placement may differ for students undertaking more acculturative adjustments. Further research is needed to understand this and to identify placement support strategies.

  19. Film Processing Module for Automated Fiber Placement

    NASA Technical Reports Server (NTRS)

    Hulcher, A. Bruce

    2004-01-01

    This viewgraph presentation describes fiber placement technology which was originally developed by Marshall Space Flight Center (MSFC) for the fabrication of fiber composite propellant tanks. The presentation includes an image of the MSFC Fiber Placement Machine, which is a prototype test bed, and images of some of the machine's parts. Some possible applications for the machines are listed.

  20. Self-aligned quadruple patterning-compliant placement

    NASA Astrophysics Data System (ADS)

    Nakajima, Fumiharu; Kodama, Chikaaki; Nakayama, Koichi; Nojima, Shigeki; Kotani, Toshiya

    2015-03-01

    Self-Aligned Quadruple Patterning (SAQP) will be one of the leading candidates for sub-14nm node and beyond. However, compared with triple patterning, making a feasible standard cell placement has following problems. (1) When coloring conflicts occur between two adjoining cells, they may not be solved easily since SAQP layout has stronger coloring constraints. (2) SAQP layout cannot use stitch to solve coloring conflict. In this paper, we present a framework of SAQP-aware standard cell placement considering the above problems. When standard cell is placed, the proposed method tries to solve coloring conflicts between two cells by exchanging two of three colors. If some conflicts remain between adjoining cells, dummy space will be inserted to keep coloring constraints of SAQP. We show some examples to confirm effectiveness of the proposed framework. To our best knowledge, this is the first framework of SAQP-aware standard cell placement.

  1. The Effect of Product Placement Marketing on Effectiveness of Internet Advertising

    NASA Astrophysics Data System (ADS)

    Liao, Hsiu-Li; Liu, Su-Houn; Pi, Shih-Ming; Chen, Hui-Ju

    Compared to the traditional way of doing advertising, such as ad Banners, internet product placement is now emerging as a promising strategy for advertisers to do their job effectively in this Web 2.0 era. Therefore, this study focuses on the effectiveness of product placement advertising on the Internet. The results show that product prominence (Subtle or Prominent) and presentation of the advertising (Video or Images) significantly impacts the effectiveness of product placement advertising on the Internet, including brand impression, advertising attitude, and intention to click. Product prominence and presentation of the advertisement have an interactive impact. Our findings indicated that presenting the product through videos will enhance higher levels of advertising attitude, brand impression, and intention to click than presenting it through still images. Subtle placements will increase the level of advertising attitude and intention to click more so than prominent placements. But prominent placements increase the brand impression more than the subtle placements.

  2. Heat tube device

    NASA Technical Reports Server (NTRS)

    Khattar, Mukesh K. (Inventor)

    1990-01-01

    The present invention discloses a heat tube device through which a working fluid can be circulated to transfer heat to air in a conventional air conditioning system. The heat tube device is disposable about a conventional cooling coil of the air conditioning system and includes a plurality of substantially U-shaped tubes connected to a support structure. The support structure includes members for allowing the heat tube device to be readily positioned about the cooling coil. An actuatable adjustment device is connected to the U-shaped tubes for allowing, upon actuation thereof, for the heat tubes to be simultaneously rotated relative to the cooling coil for allowing the heat transfer from the heat tube device to air in the air conditioning system to be selectively varied.

  3. Pulse tube cooler having 1/4 wavelength resonator tube instead of reservoir

    NASA Technical Reports Server (NTRS)

    Gedeon, David R. (Inventor)

    2008-01-01

    An improved pulse tube cooler having a resonator tube connected in place of a compliance volume or reservoir. The resonator tube has a length substantially equal to an integer multiple of 1/4 wavelength of an acoustic wave in the working gas within the resonator tube at its operating frequency, temperature and pressure. Preferably, the resonator tube is formed integrally with the inertance tube as a single, integral tube with a length approximately 1/2 of that wavelength. Also preferably, the integral tube is spaced outwardly from and coiled around the connection of the regenerator to the pulse tube at a cold region of the cooler and the turns of the coil are thermally bonded together to improve heat conduction through the coil.

  4. This is Advertising! Effects of Disclosing Television Brand Placement on Adolescents.

    PubMed

    van Reijmersdal, Eva A; Boerman, Sophie C; Buijzen, Moniek; Rozendaal, Esther

    2017-02-01

    As heavy media users, adolescents are frequently exposed to embedded advertising formats such as brand placements. Because this may lead to unwitting persuasion, regulations prescribe disclosure of brand placements. This study aimed to increase our understanding of the effects of disclosing television brand placements and disclosure duration on adolescents' persuasion knowledge (i.e., recognition of brand placement as being advertising, understanding that brand placement has a persuasive intent and critical attitude toward brand placement) and brand responses (i.e., brand memory and brand attitude). To do so, an earlier study that was conducted among adults was replicated among adolescents aged 13-17 years (N = 221, 44 % female). The present study shows that brand placement disclosure had limited effects on adolescents' persuasion knowledge as it only affected adolescents' understanding of persuasive intent, did not mitigate persuasion, but did increase brand memory. These findings suggest that brand placement disclosure has fundamentally different effects on adolescents than on adults: the disclosures had less effects on activating persuasion knowledge and mitigating persuasion among adolescents than among adults. Implications for advertising disclosure regulation and consequences for advertisers are discussed.

  5. Emerging: An Art Field Placement's Impact on Practice

    ERIC Educational Resources Information Center

    Averett, Paige; Spence, Christina Hall

    2018-01-01

    This exploratory study examined the experiences of 9 stakeholders in an art gallery field placement during their social work education. The study sought to understand how the nontraditional field placement prepared students for practice. In addition, personality traits of students that best fit the placement was examined. Findings suggest that…

  6. Evaluation of the benefits of gastric tube feeding in an elderly population.

    PubMed

    Weaver, J P; Odell, P; Nelson, C

    1993-09-01

    To assess the benefits of gastric tube feeding in an elderly community hospital population. One hundred consecutive patients who required feeding gastrostomies from July 1984 through June 1987. Durham (NC) Regional Hospital, a 380-bed community hospital. Patients were evaluated using a quality of life scale (QL scale) adapted from Spitzer's QL Index. The evaluation was based on hospital records at the time of tube placement and interviews with patients or family members at follow-up between June 1991 and March 1992. Subjective evaluation of the benefits of gastric tube feeding were obtained in interviews with patients or their families at follow-up. Overall there was no significant change in the objective evaluation of quality of life at follow-up. Men, patients over 76 years of age, and patients with chronic illnesses such as multiple strokes or dementia showed the poorest response on the QL scale. Subjective evaluation by patients or their family members was positively correlated with objective evaluation on the QL scale. Family members of patients who showed the poorest response on the QL scale were more likely than other family members to respond no to the question, "Would you want this done to you if you were in his/her situation?" Our QL scale provides a good indication of patients' and family members' subjective evaluation of the benefits of gastrostomy tube feeding after 4 to 8 years. Thus, the scale should be helpful to physicians who must consult with patients and their families and make decisions about the use of this procedure. The significant discrepancy between family members' evaluations of the benefit of the procedure to the patient and their refusal of the procedure for themselves if they were in the patient's situation confirms the need for advance directives and the importance of conscientious implementation of the Patient Self Determination Act of 1990.

  7. [Application of trans-abdominal-mediastinal drainage tube in patients with high risk of esophagogastric or esophago-jejunal anastomotic leakage].

    PubMed

    Wang, Gang-cheng; Han, Guang-sen; Ren, Ying-kun

    2012-08-01

    To evaluate the therapeutic effects of trans-abdominal-mediastinal drainage tube on the prevention of esophagogastric or esophago-jejunal anastomotic leakage. A total of 79 patients underwent thoraco-abdominal radical resection for gastric cardia cancer, with high risk of leakage of the anatsomosis, from Aug. 2007 to Aug. 2011 were included in this study. They were assigned into 2 groups. Forty one patients had trans-abdominal-mediastinal drainage tube (improvement group) and 38 patients were without the mediastinal drainage tube (control group). The clinical data of all the 79 patients were reviewed and the therapeutic effects of the two treatment approaches were compared. There was anastomotic leakage in four patients of the improvement group. They were with stable vital signs and the median hospital stay was 29.3 days. There was anastomotic leakage in five cases of the contol group and all of them had high fever and chest tightness. One among those five patients had transdermal placement of thoracic drainage tube and was cured, and four among those five patients had second debridement operation, with 3 cured and one death case. Except the one death case, the median hospital stay of the control group was 53.4 days, significantly longer than that of the improvement group (P < 0.05). Although putting trans-abdominal-mediastinal drainage tube can not prevent the leakage of esophagogastric or esophago-jejunnal anastomosis, it can reduce the systemic inflammatory responses, death and painful suffering of the patients caused by anastomotic leakage.

  8. ESL Placement and Schools: Effects on Immigrant Achievement.

    PubMed

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra; Frisco, Michelle

    2009-05-01

    In this study, the authors explore English as a Second Language (ESL) placement as a measure of how schools label and process immigrant students. Using propensity score matching and data from the Adolescent Health and Academic Achievement Study and the National Longitudinal Study of Adolescent Health, the authors estimate the effect of ESL placement on immigrant achievement. In schools with more immigrant students, the authors find that ESL placement results in higher levels of academic performance; in schools with few immigrant students, the effect reverses. This is not to suggest a one-size-fits-all policy; many immigrant students, regardless of school composition, generational status, or ESL placement, struggle to achieve at levels sufficient for acceptance to a 4-year university. This study offers several factors to be taken into consideration as schools develop policies and practices to provide immigrant students opportunities to learn.

  9. Rotation placements help students' understanding of intensive care.

    PubMed

    Abbott, Lisa

    2011-07-01

    It is vital that children's nursing students are fit for practice when they qualify and are able to meet various essential skills as defined by the Nursing and Midwifery Council (NMC). To gain the knowledge and skills required, students need placements in areas where high dependency and potentially intensive care are delivered. Efforts to maximise the number of students experiencing intensive care as a placement have led to the development of the paediatric intensive care unit (PICU) rotation, increasing placements on the PICU from 5 to 40 per cent of the student cohort per year. The lecturer practitioner organises the rotation, providing credible links between university and practice areas, while supporting students and staff in offering a high-quality placement experience. Students say the rotation offers a positive insight into PICU nursing, helping them develop knowledge and skills in a technical area and creating an interest in this specialty.

  10. Improvement of pump tubes for gas guns and shock tube drivers

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.

    1990-01-01

    In a pump tube, a gas is mechanically compressed, producing very high pressures and sound speeds. The intensely heated gas produced in such a tube can be used to drive light gas guns and shock tubes. Three concepts are presented that have the potential to allow substantial reductions in the size and mass of the pump tube to be achieved. The first concept involves the use of one or more diaphragms in the pump tube, thus replacing a single compression process by multiple, successive compressions. The second concept involves a radical reduction in the length-to-diameter ratio of the pump tube and the pump tube piston. The third concept involves shock heating of the working gas by high explosives in a cyclindrical geometry reusable device. Preliminary design analyses are performed on all three concepts and they appear to be quite feasible. Reductions in the length and mass of the pump tube by factors up to about 11 and about 7, respectively, are predicted, relative to a benchmark conventional pump tube.

  11. Better Prepared, Better Placement: An Online Resource for Health Students

    ERIC Educational Resources Information Center

    Grace, Sandra; O'Neil, Ross

    2014-01-01

    Despite calls for better preparation of students and supervisors for clinical placement, few dedicated pre-placement resources have been developed. The aim of this project was to design, pilot, and evaluate an online resource to prepare health students and supervisors for clinical placements. Development of an online resource was informed by the…

  12. Social Learning in a Longitudinal Integrated Clinical Placement

    ERIC Educational Resources Information Center

    Roberts, Chris; Daly, Michele; Held, Fabian; Lyle, David

    2017-01-01

    Recent research has demonstrated that longitudinal integrated placements (LICs) are an alternative mode of clinical education to traditional placements. Extended student engagement in community settings provide the advantages of educational continuity as well as increased service provision in underserved areas. Developing and maintaining LICs…

  13. Composite Pulse Tube

    NASA Technical Reports Server (NTRS)

    Martin, Jerry L.; Cloyd, Jason H.

    2007-01-01

    A modification of the design of the pulse tube in a pulse-tube cryocooler reduces axial thermal conductance while preserving radial thermal conductance. It is desirable to minimize axial thermal conductance in the pulse-tube wall to minimize leakage of heat between the warm and cold ends of the pulse tube. At the same time, it is desirable to maximize radial thermal conductance at the cold end of the pulse tube to ensure adequate thermal contact between (1) a heat exchanger in the form of a stack of copper screens inside the pulse tube at the cold end and (2) the remainder of the cold tip, which is the object to which the heat load is applied and from which heat must be removed. The modified design yields a low-heat-leak pulse tube that can be easily integrated with a cold tip. A typical pulse tube of prior design is either a thin-walled metal tube or a metal tube with a nonmetallic lining. It is desirable that the outer surface of a pulse tube be cylindrical (in contradistinction to tapered) to simplify the design of a regenerator that is also part of the cryocooler. Under some conditions, it is desirable to taper the inner surface of the pulse tube to reduce acoustic streaming. The combination of a cylindrical outer surface and a tapered inner surface can lead to unacceptably large axial conduction if the pulse tube is made entirely of metal. Making the pulse-tube wall of a nonmetallic, lowthermal- conductivity material would not solve the problem because the wall would not afford the needed thermal contact for the stack of screens in the cold end. The modified design calls for fabricating the pulse tube in two parts: a longer, nonmetallic part that is tapered on the inside and cylindrical on the outside and a shorter, metallic part that is cylindrical on both the inside and the outside. The nonmetallic part can be made from G-10 fiberglass-reinforced epoxy or other low-thermal-conductivity, cryogenically compatible material. The metallic part must have high

  14. Tube thoracostomy; chest tube implantation and follow up

    PubMed Central

    Kuhajda, Ivan; Zarogoulidis, Konstantinos; Kougioumtzi, Ioanna; Huang, Haidong; Li, Qiang; Dryllis, Georgios; Kioumis, Ioannis; Pitsiou, Georgia; Machairiotis, Nikolaos; Katsikogiannis, Nikolaos; Papaiwannou, Antonis; Lampaki, Sofia; Papaiwannou, Antonis; Zaric, Bojan; Branislav, Perin; Porpodis, Konstantinos

    2014-01-01

    Pneumothorax is an urgent medical situation that requires urgent treatment. We can divide this entity based on the etiology to primary and secondary. Chest tube implantation can be performed either in the upper chest wall or lower. Both thoracic surgeons and pulmonary physicians can place a chest tube with minimal invasive techniques. In our current work, we will demonstrate chest tube implantation to locations, methodology and tools. PMID:25337405

  15. Angioplasty and stent placement - heart

    MedlinePlus

    PCI; Percutaneous coronary intervention; Balloon angioplasty; Coronary angioplasty; Coronary artery angioplasty; Percutaneous transluminal coronary angioplasty; Heart artery dilatation; Angina - stent placement; Acute coronary ...

  16. Fluoroscopic Placement of Double-Pigtail Ureteral Stents

    PubMed Central

    Chen, Gregory L.

    2001-01-01

    Purpose: Double-pigtail ureteral stent is placed cystoscopically after ureteroscopy. We describe a technique for fluoroscopic placement of ureteral stents and demonstrate its use in a non-randomized prospective study. Materials and methods: Double-pigtail stents were placed either fluoroscopically or cystoscopically in 121 consecutive patients. In the fluoroscopic method, the stent was placed over a guide wire using a stent pusher without the use of cystoscopy. Conversely, stents were placed through the working channel of the cystoscope under vision. The procedure, stent length, width, type, method, ureteral dilation, and use of a retrieval string were noted. Results: A wide range of stent sizes were used. The success with fluoroscopic placement of double-pigtail ureteral stents was 100% (89 of 89 cases). No stents migrated or required replacement. Stents were placed after ureteroscopic laser lithotripsy (53/89) and ureteroscopic tumor treatment (22/89). Cystoscopic visualization was used in 32 additional procedures requiring precise control (15 ureteral strictures and nine retrograde endopyelotomy). Conclusions: The fluoroscopic placement of ureteral stents is a safe and simple technique with a very high success rate. We have used cystoscopic placement only after incisional procedures such as retrograde endopyelotomy, stricture or ureterotomy. PMID:18493562

  17. Telescoping tube assembly

    NASA Technical Reports Server (NTRS)

    Sturm, Albert J. (Inventor); Marrinan, Thomas E. (Inventor)

    1995-01-01

    An extensible and retractable telescoping tube positions test devices that inspect large stationary objects. The tube has three dimensional adjustment capabilities and is vertically suspended from a frame. The tube sections are independently supported with each section comprising U-shaped housing secured to a thicker support plate. Guide mechanisms preferably mounted only to the thicker plates guide each tube section parallel to a reference axis with improved accuracy so that the position of the remote end of the telescoping tube is precisely known.

  18. A neuromechanical strategy for mediolateral foot placement in walking humans.

    PubMed

    Rankin, Bradford L; Buffo, Stephanie K; Dean, Jesse C

    2014-07-15

    Stability is an important concern during human walking and can limit mobility in clinical populations. Mediolateral stability can be efficiently controlled through appropriate foot placement, although the underlying neuromechanical strategy is unclear. We hypothesized that humans control mediolateral foot placement through swing leg muscle activity, basing this control on the mechanical state of the contralateral stance leg. Participants walked under Unperturbed and Perturbed conditions, in which foot placement was intermittently perturbed by moving the right leg medially or laterally during the swing phase (by ∼50-100 mm). We quantified mediolateral foot placement, electromyographic activity of frontal-plane hip muscles, and stance leg mechanical state. During Unperturbed walking, greater swing-phase gluteus medius (GM) activity was associated with more lateral foot placement. Increases in GM activity were most strongly predicted by increased mediolateral displacement between the center of mass (CoM) and the contralateral stance foot. The Perturbed walking results indicated a causal relationship between stance leg mechanics and swing-phase GM activity. Perturbations that reduced the mediolateral CoM displacement from the stance foot caused reductions in swing-phase GM activity and more medial foot placement. Conversely, increases in mediolateral CoM displacement caused increased swing-phase GM activity and more lateral foot placement. Under both Unperturbed and Perturbed conditions, humans controlled their mediolateral foot placement by modulating swing-phase muscle activity in response to the mechanical state of the contralateral leg. This strategy may be disrupted in clinical populations with a reduced ability to modulate muscle activity or sense their body's mechanical state.

  19. 25 CFR 26.4 - Who administers the Job Placement and Training Program?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Who administers the Job Placement and Training Program... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training Program? The Job Placement and Training Program is administered by the Bureau of Indian Affairs or a...

  20. The Placement Handbook. A Guide for the Competitive Employment of the Handicapped.

    ERIC Educational Resources Information Center

    Horn, Adelaide; Drury, Stephen

    This handbook stresses those components that are considered peripheral to the placement process but that must precede the actual placement. The philosophy of placement upon which this guide is based appears first. Discussions follow of the basic components of the process of training and placement of handicapped individuals, including a varied…

  1. Bender/Coiler for Tubing

    NASA Technical Reports Server (NTRS)

    Stoltzfus, J. M.

    1983-01-01

    Easy-to-use tool makes coils of tubing. Tubing to be bend clamped with stop post. Die positioned snugly against tubing. Operator turns handle to slide die along tubing, pushing tubing into spiral groove on mandrel.

  2. 34 CFR 300.115 - Continuum of alternative placements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... EDUCATION OF CHILDREN WITH DISABILITIES State Eligibility Least Restrictive Environment (lre) § 300.115... placements is available to meet the needs of children with disabilities for special education and related... 34 Education 2 2010-07-01 2010-07-01 false Continuum of alternative placements. 300.115 Section...

  3. Student Transcript-Enhanced Placement Study (STEPS). Technical Report

    ERIC Educational Resources Information Center

    Willett, Terrence

    2013-01-01

    Prior research suggests that using high school transcripts may improve English and math placement accuracy at colleges. Between 2012 and 2013, the Research and Planning Group for California Community Colleges (RP Group) conducted the Student Transcript Enhanced Placement Study (STEPS) in partnership with the California Community Colleges…

  4. Placement of Students with Emotional and Behavioral Disorders

    ERIC Educational Resources Information Center

    Mathur, Sarup R.; Jolivette, Kristine

    2012-01-01

    Students with emotional and behavioral disorders (E/BD) receive educational and related services within a continuum of placement options per the Individual with Disabilities Education Act. The continuum of placement options ranges from fully included general education type classrooms to more restrictive environments such as alternative education…

  5. FtsZ Placement in Nucleoid-Free Bacteria

    PubMed Central

    Pazos, Manuel; Casanova, Mercedes; Palacios, Pilar; Margolin, William; Natale, Paolo; Vicente, Miguel

    2014-01-01

    We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO). A second septum placement mechanism, the MinCDE system (Min) involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*), a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement. PMID:24638110

  6. FtsZ placement in nucleoid-free bacteria.

    PubMed

    Pazos, Manuel; Casanova, Mercedes; Palacios, Pilar; Margolin, William; Natale, Paolo; Vicente, Miguel

    2014-01-01

    We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO). A second septum placement mechanism, the MinCDE system (Min) involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*), a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement.

  7. Investigation on the Inertance Tubes of Pulse Tube Cryocooler Without Reservoir

    NASA Astrophysics Data System (ADS)

    Liu, Y. J.; Yang, L. W.; Liang, J. T.; Hong, G. T.

    2010-04-01

    Phase angle is of vital importance for high-efficiency pulse tube cryocoolers (PTCs). Inertance tube as the main phase shifter is useful for the PTCs to obtain appropriate phase angle. Experiments of inertance tube without reservoir under variable frequency, variable length and diameter of inertance tube and variable pressure amplitude are investigated respectively. In addition, the authors used DeltaEC, a computer program to predict the performance of low-amplitude thermoacoustic engines, to simulate the effects of inertance tube without reservoir. According to the comparison of experiments and theoretical simulations, DeltaEC method is feasible and effective to direct and improve the design of inertance tubes.

  8. Kaumana lava tube

    NASA Technical Reports Server (NTRS)

    Greeley, R.

    1974-01-01

    The entrance to Kaumana Lava Tube is in a picnic ground next to Highway 20 (Kaumana Drive) about 6.5 km southwest of Hilo. The area is passed on the way to the Kona Coast via the Saddle Road and is identified by a Hawaii Visitors Bureau sign. Although it is not the largest lava tube in the islands, Kaumana Lava Tube is an interesting geological formation, displaying many of the features typical of lava tube interiors. It is accessible, relatively easy to walk through, and is in an excellent state of preservation. The tube developed in a historic lava flow (1881, from Mauna Loa), and many aspects of lava tube activity are observed.

  9. Multiple tube premixing device

    DOEpatents

    Uhm, Jong Ho; Naidu, Balachandar; Ziminksy, Willy Steve; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin; Stevenson, Christian; Felling, David

    2013-08-13

    The present application provides a premixer for a combustor. The premixer may include a fuel plenum with a number of fuel tubes and a burner tube with a number of air tubes. The fuel tubes extend about the air tubes.

  10. Multiple tube premixing device

    DOEpatents

    Uhm, Jong Ho; Varatharajan, Balachandar; Ziminsky, Willy Steve; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin; Stevenson, Christian; Felling, David

    2012-12-11

    The present application provides a premixer for a combustor. The premixer may include a fuel plenum with a number of fuel tubes and a burner tube with a number of air tubes. The fuel tubes extend about the air tubes.

  11. 46 CFR 111.01-3 - Placement of equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Placement of equipment. 111.01-3 Section 111.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-3 Placement of equipment. (a) Electric equipment must be arranged...

  12. 46 CFR 111.01-3 - Placement of equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Placement of equipment. 111.01-3 Section 111.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-3 Placement of equipment. (a) Electric equipment must be arranged...

  13. 46 CFR 111.01-3 - Placement of equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Placement of equipment. 111.01-3 Section 111.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-3 Placement of equipment. (a) Electric equipment must be arranged...

  14. Curriculum for Training Job Placement Personnel in Michigan.

    ERIC Educational Resources Information Center

    Ferris State Coll., Big Rapids, MI. Center for Occupational Education.

    A study was conducted to determine what job placement specialists need, as professionals, to be better equipped to serve the employment-seeking population. Survey information was gathered from four sets of sources: job placement personnel; business and industry; a nationwide survey of programs; organizations, training, and curriculum existing in…

  15. 7 CFR 15b.24 - Evaluation and placement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...

  16. 7 CFR 15b.24 - Evaluation and placement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...

  17. 46 CFR 111.01-3 - Placement of equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Placement of equipment. 111.01-3 Section 111.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-3 Placement of equipment. (a) Electric equipment must be arranged...

  18. 46 CFR 111.01-3 - Placement of equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Placement of equipment. 111.01-3 Section 111.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-3 Placement of equipment. (a) Electric equipment must be arranged...

  19. 7 CFR 15b.24 - Evaluation and placement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...

  20. 7 CFR 15b.24 - Evaluation and placement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...

  1. 46 CFR 130.460 - Placement of machinery alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...

  2. 46 CFR 130.460 - Placement of machinery alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...

  3. 46 CFR 130.460 - Placement of machinery alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...

  4. 46 CFR 130.460 - Placement of machinery alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Placement of machinery alarms. 130.460 Section 130.460..., AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.460 Placement of machinery alarms. (a) Visible and audible alarms must be installed at the pilothouse to indicate...

  5. Retrovirus Studies in Nonhuman Primates at Four Regional Primate Research Centers.

    DTIC Science & Technology

    1990-09-30

    inoculation of the vaginal mucosa with SIV-infected splenocytes. The Heterosexual Transmission of AIDS: A Simian Model. The overall objective of this...rhesus macaques. We have previously reported that SIV can be transmitted across the vaginal mucosa of female rhesus macaques (Miller, et. al., 1990). To...infused through a 2.5mm outer diameter (8 French) soft, plastic, pediatric nasogastric feeding tube (American Pharmaseal, Valencia, Ca.) into the 3 vaginal

  6. Control of human gait stability through foot placement.

    PubMed

    Bruijn, Sjoerd M; van Dieën, Jaap H

    2018-06-01

    During human walking, the centre of mass (CoM) is outside the base of support for most of the time, which poses a challenge to stabilizing the gait pattern. Nevertheless, most of us are able to walk without substantial problems. In this review, we aim to provide an integrative overview of how humans cope with an underactuated gait pattern. A central idea that emerges from the literature is that foot placement is crucial in maintaining a stable gait pattern. In this review, we explore this idea; we first describe mechanical models and concepts that have been used to predict how foot placement can be used to control gait stability. These concepts, such as for instance the extrapolated CoM concept, the foot placement estimator concept and the capture point concept, provide explicit predictions on where to place the foot relative to the body at each step, such that gait is stabilized. Next, we describe empirical findings on foot placement during human gait in unperturbed and perturbed conditions. We conclude that humans show behaviour that is largely in accordance with the aforementioned concepts, with foot placement being actively coordinated to body CoM kinematics during the preceding step. In this section, we also address the requirements for such control in terms of the sensory information and the motor strategies that can implement such control, as well as the parts of the central nervous system that may be involved. We show that visual, vestibular and proprioceptive information contribute to estimation of the state of the CoM. Foot placement is adjusted to variations in CoM state mainly by modulation of hip abductor muscle activity during the swing phase of gait, and this process appears to be under spinal and supraspinal, including cortical, control. We conclude with a description of how control of foot placement can be impaired in humans, using ageing as a primary example and with some reference to pathology, and we address alternative strategies available to

  7. Torsion Tests of Tubes

    NASA Technical Reports Server (NTRS)

    Stang, Ambrose H; Ramberg, Walter; Back, Goldie

    1937-01-01

    This report presents the results of tests of 63 chromium-molybdenum steel tubes and 102 17st aluminum-alloy tubes of various sizes and lengths made to study the dependence of the torsional strength on both the dimensions of the tube and the physical properties of the tube material. Three types of failure are found to be important for sizes of tubes frequently used in aircraft construction: (1) failure by plastic shear, in which the tube material reached its yield strength before the critical torque was reached; (2) failure by elastic two-lobe buckling, which depended only on the elastic properties of the tube material and the dimensions of the tube; and (3) failure by a combination of (1) and (2) that is, by buckling taking place after some yielding of the tube material.

  8. Placement Mentors Making Sense of Research-Based Knowledge

    ERIC Educational Resources Information Center

    Raaen, Finn Daniel

    2017-01-01

    Placement mentors' role increasingly implies demonstrating to student teachers how research-based knowledge in combination with experience-based knowledge may be relevant in teachers' professional work. This is a challenge. Placement mentors are often unsure how to make sense of research-based knowledge. Frequently there is a mismatch between what…

  9. A simple blind placement of the left-sided double-lumen tubes.

    PubMed

    Zong, Zhi Jun; Shen, Qi Ying; Lu, Yao; Li, Yuan Hai

    2016-11-01

    One-lung ventilation (OLV) has been commonly provided by using a double-lumen tube (DLT). Previous reports have indicated the high incidence of inappropriate DLT positioning in conventional maneuvers.After obtaining approval from the medical ethics committee of First Affiliated Hospital of Anhui Medical University and written consent from patients, 88 adult patients belonging to American society of anesthesiologists (ASA) physical status grade I or II, and undergoing elective thoracic surgery requiring a left-side DLT for OLV were enrolled in this prospective, single-blind, randomized controlled study. Patients were randomly allocated to 1 of 2 groups: simple maneuver group or conventional maneuver group. The simple maneuver is a method that relies on partially inflating the bronchial balloon and recreating the effect of a carinal hook on the DLTs to give an idea of orientation and depth. After the induction of anesthesia the patients were intubated with a left-sided Robertshaw DLT using one of the 2 intubation techniques. After intubation of each DLT, an anesthesiologist used flexible bronchoscopy to evaluate the patient while the patient lay in a supine position. The number of optimal position and the time required to place DLT in correct position were recorded.Time for the intubation of DLT took 100 ± 16.2 seconds (mean ± SD) in simple maneuver group and 95.1 ± 20.8 seconds in conventional maneuver group. The difference was not statistically significant (P = 0.221). Time for fiberoptic bronchoscope (FOB) took 22 ± 4.8 seconds in simple maneuver group and was statistically faster than that in conventional maneuver group (43.6 ± 23.7 seconds, P < 0.001). Nearly 98% of the 44 intubations in simple maneuver group were considered as in optimal position while only 52% of the 44 intubations in conventional maneuver group were in optimal position, and the difference was statistically significant (P < 0.001).This simple

  10. Mathematics Course Placement Using Holistic Measures: Possibilities for Community College Students

    ERIC Educational Resources Information Center

    Ngo, Federick; Chi, W. Edward; Park, Elizabeth So Yun

    2018-01-01

    Background/Context: Most community colleges across the country use a placement test to determine students' readiness for college-level coursework, yet these tests are admittedly imperfect instruments. Researchers have documented significant problems stemming from overreliance on placement testing, including placement error and misdiagnosis of…

  11. Needle aspiration versus intercostal tube drainage for pneumothorax in the newborn.

    PubMed

    Bruschettini, Matteo; Romantsik, Olga; Ramenghi, Luca Antonio; Zappettini, Simona; O'Donnell, Colm P F; Calevo, Maria Grazia

    2016-01-11

    randomised controlled trial (72 infants) met the inclusion criteria of this review. We found no differences in the rates of mortality (risk ratio (RR) 1.50, 95% confidence interval (CI) 0.27 to 8.45) or complications related to the procedure. After needle aspiration, the angiocatheter was left in situ (mean 27.1 hours) and not removed immediately after the aspiration. The angiocatheter was in place for a shorter duration than the intercostal tube (mean difference (MD) -11.20 hours, 95% CI -15.51 to -6.89). None of the 36 newborns treated with needle aspiration with the angiocatheter left in situ required the placement of an intercostal tube drainage. Overall, the quality of the evidence supporting this finding is low. At present there is insufficient evidence to determine the efficacy and safety of needle aspiration versus intercostal tube drainage in the management of neonatal pneumothorax. Randomised controlled trials comparing the two techniques are warranted.

  12. Strategic Plan for Student Placement Services. Preliminary Report.

    ERIC Educational Resources Information Center

    Dickson, C. R.; Garber, M.

    A proposal is presented for the integration and consolidation of Student Placement Services with the Co-operative Education Division at Mohawk College in Ontario. Developed in response to an announcement by the Canadian Employment and Immigration Commission that it would withdraw all support for student placement services at the college by 1991,…

  13. Continuation of Pilot Program for Training Placement Personnel.

    ERIC Educational Resources Information Center

    Southern Illinois Univ., Carbondale. Dept. of Vocational Education Studies.

    Twelve members of school faculty and staff participated in a refined competency-based continuation of a pilot program to train individuals to function as placement coordinators in their schools in southern Illinois. Participants enrolled in a weekly placement seminar on campus for the 1978-79 academic year and in a continuous supervised internship…

  14. Teacher Placement, Mobility, and Occupational Choices after Teaching

    ERIC Educational Resources Information Center

    Feng, Li

    2014-01-01

    Teachers' initial placement has important implications for student achievement and the distribution of teachers among schools. This paper combines data from a US Baccalaureate and Beyond longitudinal study with school and school district information from the Common Core of Data to study the effects of initial school placement on teacher mobility.…

  15. 40 CFR 82.108 - Placement of warning statement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Placement of warning statement. 82.108....108 Placement of warning statement. The warning statement shall be placed so as to satisfy the requirement of the Act that the warning statement be “clearly legible and conspicuous.” The warning statement...

  16. 40 CFR 82.108 - Placement of warning statement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Placement of warning statement. 82.108....108 Placement of warning statement. The warning statement shall be placed so as to satisfy the requirement of the Act that the warning statement be “clearly legible and conspicuous.” The warning statement...

  17. 40 CFR 82.108 - Placement of warning statement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Placement of warning statement. 82.108....108 Placement of warning statement. The warning statement shall be placed so as to satisfy the requirement of the Act that the warning statement be “clearly legible and conspicuous.” The warning statement...

  18. 40 CFR 82.108 - Placement of warning statement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Placement of warning statement. 82.108....108 Placement of warning statement. The warning statement shall be placed so as to satisfy the requirement of the Act that the warning statement be “clearly legible and conspicuous.” The warning statement...

  19. 40 CFR 82.108 - Placement of warning statement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Placement of warning statement. 82.108....108 Placement of warning statement. The warning statement shall be placed so as to satisfy the requirement of the Act that the warning statement be “clearly legible and conspicuous.” The warning statement...

  20. Automatic Correction of Adverb Placement Errors for CALL

    ERIC Educational Resources Information Center

    Garnier, Marie

    2012-01-01

    According to recent studies, there is a persistence of adverb placement errors in the written productions of francophone learners and users of English at an intermediate to advanced level. In this paper, we present strategies for the automatic detection and correction of errors in the placement of manner adverbs, using linguistic-based natural…

  1. Heat exchanger tube mounts

    DOEpatents

    Wolowodiuk, W.; Anelli, J.; Dawson, B.E.

    1974-01-01

    A heat exchanger in which tubes are secured to a tube sheet by internal bore welding is described. The tubes may be moved into place in preparation for welding with comparatively little trouble. A number of segmented tube support plates are provided which allow a considerable portion of each of the tubes to be moved laterally after the end thereof has been positioned in preparation for internal bore welding to the tube sheet. (auth)

  2. Multi-tube arrangement for combustor and method of making the multi-tube arrangement

    DOEpatents

    Ziminsky, Willy Steve [Simpsonville, SC

    2012-07-31

    A fuel injector tube includes a one piece, unitary, polygonal tube having an inlet end and an outlet end. The fuel injector tube further includes a fuel passage extending from the inlet end to the outlet end along a longitudinal axis of the polygonal tube, a plurality of air passages extending from the inlet end to the outlet end and surrounding the fuel passage, and a plurality of fuel holes. Each fuel hole connects an air passage with the fuel passage. The inlet end of the polygonal tube is formed into a fuel tube. A fuel injector includes a plurality of fuel injector tubes and a plate. The plurality of fuel tubes are connected to the plate adjacent the inlet ends of the plurality of fuel injector tubes.

  3. Research: Hyperactivity, Placement Centers

    ERIC Educational Resources Information Center

    Nation's Schools and Colleges, 1975

    1975-01-01

    A diet that emphasizes the elimination of food containing artificial coloring and flavoring from meals served to hyperactive children has met with success in preliminary studies; college placement centers are advised to shift their emphasis from job research and counseling. (Author/MLF)

  4. 49 CFR 230.61 - Arch tubes, water bar tubes, circulators and thermic siphons.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Arch tubes, water bar tubes, circulators and... MAINTENANCE STANDARDS Boilers and Appurtenances Washing Boilers § 230.61 Arch tubes, water bar tubes... water bar tubes shall thoroughly be cleaned mechanically, washed, and inspected. Circulators and thermic...

  5. Life cycle assessment for dredged sediment placement strategies.

    PubMed

    Bates, Matthew E; Fox-Lent, Cate; Seymour, Linda; Wender, Ben A; Linkov, Igor

    2015-04-01

    Dredging to maintain navigable waterways is important for supporting trade and economic sustainability. Dredged sediments are removed from the waterways and then must be managed in a way that meets regulatory standards and properly balances management costs and risks. Selection of a best management alternative often results in stakeholder conflict regarding tradeoffs between local environmental impacts associated with less expensive alternatives (e.g., open water placement), more expensive measures that require sediment disposal in constructed facilities far away (e.g., landfills), or beneficial uses that may be perceived as risky (e.g., beach nourishment or island creation). Current sediment-placement decisions often focus on local and immediate environmental effects from the sediment itself, ignoring a variety of distributed and long-term effects from transportation and placement activities. These extended effects have implications for climate change, resource consumption, and environmental and human health, which may be meaningful topics for many stakeholders not currently considered. Life-Cycle Assessment (LCA) provides a systematic and quantitative method for accounting for this wider range of impacts and benefits across all sediment management project stages and time horizons. This paper applies a cradle-to-use LCA to dredged-sediment placement through a comparative analysis of potential upland, open water, and containment-island placement alternatives in the Long Island Sound region of NY/CT. Results suggest that, in cases dealing with uncontaminated sediments, upland placement may be the most environmentally burdensome alternative, per ton-kilometer of placed material, due to the emissions associated with diesel fuel combustion and electricity production and consumption required for the extra handling and transportation. These results can be traded-off with the ecosystem impacts of the sediments themselves in a decision-making framework. Published by

  6. Infant Placement in Canadian Child Maltreatment-Related Investigations

    ERIC Educational Resources Information Center

    Tonmyr, Lil; Williams, Gabriela; Jack, Susan M.; MacMillan, Harriet L.

    2011-01-01

    This study examined factors associated with decisions in favour of out-of-home placement following investigations involving infants at risk of maltreatment. We used data from a sample of children less than 1 year of age (n = 763) investigated by child welfare services across Canada in 2003. We tested unadjusted relationships with placement using…

  7. Measuring the Benefits of a Psychology Placement Year

    ERIC Educational Resources Information Center

    Reddy, Peter; Moores, Elisabeth

    2006-01-01

    Placement programmes are considered to provide students with an induction into the work environment and a valuable learning experience. Aston University maintains one of the highest success rates of any UK university for graduate employment and it is thought that the placement year plays a large role in this success. However, the benefits of…

  8. Impact of an international workplace learning placement on personal and professional development.

    PubMed

    Davies, Kerryn; Curtin, Michael; Robson, Kristy

    2017-04-01

    Workplace learning (WPL) placements are a mandatory part of occupational therapy courses. There is some evidence that suggests WPL placements in international settings are beneficial for students' learning, and personal and professional development. The aim of this study was to explore the impact an international WPL placement in Vietnam had on the perceived personal and professional development of a group of Australian occupational therapy graduates. Interpretative phenomenological analysis was used to explore the perceptions of how participation in the Charles Sturt University School of Community Health's Vietnam placement influenced the personal and professional development of occupational therapy graduates. Individual semi-structured interviews were conducted with nine graduates who participated in the Vietnam placement when they were final year occupational therapy students. Interviews were audio-recorded, transcribed verbatim and individually analysed to identify key themes. Two major themes emerged from the analysis: becoming resourceful, resilient and confident, and becoming respectful of difference. The participants indicated that participation in the Vietnam placement had a positive impact on their personal and professional development. Participants indicated that the Vietnam placement enabled them to develop their resourcefulness, resilience, reasoning skills, cultural competence, confidence and independence, beyond what they felt would have achieved on a domestic placement. For these reason these participants found the placement a beneficial and worthwhile experience. © 2016 Occupational Therapy Australia.

  9. Foster care placement change: The role of family dynamics and household composition

    PubMed Central

    Waid, Jeffrey; Kothari, Brianne H.; Bank, Lew; McBeath, Bowen

    2016-01-01

    Sibling co-placement and kinship care have each been shown to protect against the occurrence of placement change for youth in substitute care. However, little is known about the effects of different combinations of sibling placement and relative caregiver status on placement change. Nor does the field fully understand how family dynamics may differ in these households. Utilizing data from the Supporting Siblings in Foster Care study, this paper examines family dynamics across four typologies of living composition, and tests the effects of living composition membership on the odds of experiencing a placement change over an 18-month period of time. Findings suggest that across living composition typologies, children who were placed separately from their siblings in non-relative care were more likely to be older, have more extensive placement histories, and experience more placement changes both prior to and during the study than were children in other living composition groups. Family living composition was found to influence the occurrence of placement change. Specifically, children co-placed in kinship care were least likely to experience movement; however, sibling co-placement in non-relative care was also protective. Results reveal the need to conduct additional research into the experiences of children in different family living arrangements, and tailor case management services and supports to children in substitute care accordingly. Implications and future directions are discussed. PMID:27990039

  10. Clinical placements in general practice: relationships between practice nurses and tertiary institutions.

    PubMed

    Peters, Kathleen; Halcomb, Elizabeth J; McInnes, Susan

    2013-05-01

    As a practice-based discipline a key component of undergraduate nurse education is clinical practice experience. The quality of clinical experiences has a significant impact on the students' ability to function competently post graduation. The relationship between higher education institutions (HEIs) and health service placement providers impacts upon the quality of clinical placements. In Australia, the growth of primary care nursing and the shortage of acute clinical places has prompted HEIs to explore the placement of students in general practice. Given the increasing attention being paid to non-traditional clinical placements, it is timely to explore how universities are establishing relationships and models of clinical placement. This paper uses qualitative research methods to explore the perspectives of 12 Australian general practice nurses who have experience in facilitating undergraduate clinical placements about the relationships between HEIs and nurses. Findings are presented in the following three themes: (1) Appropriate preparation for placement: They don't know what primary health really means, (2) Seeking greater consultation in the organisation of clinical placements: they've got to do it one way for everyone, and (3) Uncertainty and lack of support: I had no contact with the university. Clinical placements in general practice can be an innovative strategy providing non-traditional, yet high quality, teaching and learning experiences for undergraduate nursing students. To optimise the quality of these placements, however, it is essential that HEIs provide appropriate support to the practice nurses mentoring these students. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Ketorolac for Pain Control With Intrauterine Device Placement: A Randomized Controlled Trial

    PubMed Central

    Ngo, Lynn L.; Ward, Kristy K.; Mody, Sheila K.

    2015-01-01

    Objective To evaluate intramuscular ketorolac compared to placebo saline injection for pain control with intrauterine device (IUD) placement. Methods We conducted a randomized, double-blind, placebo controlled trial between July 2012 and March 2014. Patients received ketorolac 30mg or placebo saline intramuscular injection 30 minutes prior to IUD placement. The primary outcome was pain with IUD placement on a 10cm visual analog scale (VAS). Sample size was calculated to provide 80% power to show a 2.0cm difference (α=0.05) in the primary outcome. Secondary outcomes included pain with study drug injection, speculum insertion, tenaculum placement, uterine sounding, and at 5 and 15 minutes after IUD placement. Results A total of 67 women participated in the study, 33 in the ketorolac arm and 34 in the placebo arm. There were no differences in baseline demographics including age, BMI, and race. There were no differences in median pain scores for IUD placement in the placebo versus ketorolac groups (5.2cm vs 3.6cm, p=0.99). There was a decrease in median pain scores at 5 minutes (2.2cm vs 0.3cm, p=<0.001) and 15 minutes (1.6cm vs 0.1cm, p=<0.001) after IUD placement but no difference for all other time points. Nulliparous participants (n=16, 8 per arm) had a decrease in pain scores with IUD placement (8.1cm vs 5.4cm, p=0.02). In this study, 22% of participants in the placebo group and 18% in the ketorolac group reported injection pain was as painful as IUD placement. Conclusions Ketorolac does not reduce pain with IUD placement but does reduce pain at 5 and 15 minutes after placement. PMID:26241253

  12. Ketorolac for Pain Control With Intrauterine Device Placement: A Randomized Controlled Trial.

    PubMed

    Ngo, Lynn L; Ward, Kristy K; Mody, Sheila K

    2015-07-01

    To evaluate intramuscular ketorolac compared with placebo saline injection for pain control with intrauterine device (IUD) placement. We conducted a randomized, double-blind, placebo-controlled trial between July 2012 and March 2014. Patients received 30 mg ketorolac or placebo saline intramuscular injection 30 minutes before IUD placement. The primary outcome was pain with IUD placement on a 10-cm visual analog scale. Sample size was calculated to provide 80% power to show a 2.0-cm difference (α=0.05) in the primary outcome. Secondary outcomes included pain with study drug injection, speculum insertion, tenaculum placement, uterine sounding, and at 5 and 15 minutes after IUD placement. A total of 67 women participated in the study, 33 in the ketorolac arm and 34 in the placebo arm. There were no differences in baseline demographics including age, body mass index, and race. There were no differences in median pain scores for IUD placement in the placebo compared with ketorolac groups (5.2 compared with 3.6 cm, P=.99). There was a decrease in median pain scores at 5 minutes (2.2 compared with 0.3 cm, P≤.001) and 15 minutes (1.6 compared with 0.1 cm, P≤.001) after IUD placement but no difference for all other time points. Nulliparous participants (n=16, eight per arm) had a decrease in pain scores with IUD placement (8.1 compared with 5.4 cm, P=.02). In this study, 22% of participants in the placebo group and 18% in the ketorolac group reported injection pain was as painful as IUD placement. Ketorolac does not reduce pain with IUD placement but does reduce pain at 5 and 15 minutes after placement. ClinicalTrials.gov; www.clinicaltrials.gov, NCT01664559. I.

  13. 25 CFR 26.12 - Who provides the Job Placement and Training?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false Who provides the Job Placement and Training? 26.12 Section 26.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The...

  14. 25 CFR 26.12 - Who provides the Job Placement and Training?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false Who provides the Job Placement and Training? 26.12 Section 26.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The...

  15. 25 CFR 26.12 - Who provides the Job Placement and Training?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false Who provides the Job Placement and Training? 26.12 Section 26.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The...

  16. Measuring the Value of Placements to Employers: A Cost-Benefit Approach

    ERIC Educational Resources Information Center

    Wond, Tracey; Rambukwella, Shan

    2018-01-01

    This article explores the concept and measurement of placement value, underexplored in theory and practice to date. The article makes a theoretical contribution to the placement value discourse by examining and articulating the placement value concept. It also offers a practical contribution by exploring a piloted tool to evaluate employer…

  17. Placement of Intubating Laryngeal Mask Airway Is Easier than Placement of Laryngeal Tube during Manual In-Line Stabilisation of The Neck

    PubMed Central

    Komatsu, R.; Nagata, O.; Kamata, K.; Yamagata, K.; Sessler, D.I.; Ozaki, M.

    2005-01-01

    Summary We compared the usefulness of the laryngeal tube (LT) with the intubating laryngeal mask airway (ILMA) in 51 patients whose necks were stabilised by manual in-line traction. After induction of anaesthesia and neuromuscular block, the LT and ILMA were inserted consecutively in a randomised, crossover design. During pressure-controlled ventilation (20 cmH2O inspiratory pressure), we measured insertion attempts, time to establish positive-pressure ventilation, tidal volume, gastric insufflation, and minimum airway pressure at which gas leaked around the cuff. Data were compared using Wilcoxon signed-rank tests; P<0.05 was considered significant. Insertion was more difficult with the LT (successful at first attempt in 16 patients) than with the ILMA (successful at first attempt in 42 patients, P<0.0001). Time required for insertion was longer for the LT (28 [23–35] sec, median [interquartile range]) than the ILMA (20 [15–25] sec, P=0.0009). Tidal volume was less for the LT (440 [290–670] ml) than the ILMA. (630 [440–750] ml, P=0.013). Minimum airway pressure at which gas leak occurred and incidence of gastric insufflation were similar with two devices. In patients whose necks were stabilised with manual in-line traction, insertion of the ILMA was easier and quicker than insertion of the LT and tidal volume was greater with the ILMA than the LT. PMID:15644005

  18. Gastric emptying of cold beverages in humans: effect of transportable carbohydrates.

    PubMed

    Shi, X; Bartoli, W; Horn, M; Murray, R

    2000-12-01

    Eight healthy subjects, aged 39.0 ¿ 2.4 years, consumed four 6% carbohydrate-electrolyte solutions containing either one (glucose or fructose) or two transportable carbohydrates in single (glucose + fructose) or bound (sucrose) forms. Solution osmolalities ranged from 250 to 434 mOsm/kg H2O. The test solutions were ingested at rest in the amount of 6 ml/kg of body weight at a temperature of 12 ¿C. Gastric emptying rate was measured by repeated aspirations via a nasogastric tube using the modified George double-sampling technique. The intragastric temperature was determined by a temperature probe attached to the nasogastric tube. There were no significant differences in gastric emptying rates and gastric volumes among the solutions. Intragastric temperature dropped from 36.5 ¿C to 23.3 ¿ 3 ¿C immediately after beverage ingestion but recovered to above 30 ¿C within 5 min. These data suggest that the gastric emptying rate of the specified beverages is not affected by the number and type of carbohydrates or by solution osmolalities within the tested range. Within 5 min after ingestion, cold beverages are warmed to above 30 C in the stomach. This infers that the effect of cold solution temperature on gastric emptying rate is likely to be small and transitory.

  19. Gastro-oesophageal reflux in mechanically ventilated patients: effects of an oesophageal balloon.

    PubMed

    Orozco-Levi, M; Félez, M; Martínez-Miralles, E; Solsona, J F; Blanco, M L; Broquetas, J M; Torres, A

    2003-08-01

    Gastro-oesophageal reflux (GOR) and bronchoaspiration of gastric content are risk factors linked with ventilator-associated pneumonia. This study was aimed at evaluating the effect of a nasogastric tube (NGT) incorporating a low-pressure oesophageal balloon on GOR and bronchoaspiration in patients receiving mechanical ventilation. Fourteen patients were studied in a semi-recumbent position for 2 consecutive days. Inflation or deflation of the oesophageal balloon was randomised. Samples of blood, gastric content, and oropharyngeal and bronchial secretions were taken every 2 h over a period of 8 h. A radioactively labelled nutritional solution was continuously administered through the NGT. The magnitude of both the GOR and bronchoaspiration was measured by radioactivity counting of oropharyngeal and bronchial secretion samples, respectively. Inflation of the oesophageal balloon resulted in a significant decrease of both GOR and bronchoaspiration of gastric content. This protective effect was statistically significant from 4 h following inflation throughout the duration of the study. This study demonstrates that an inflated oesophageal balloon delays and decreases gastro-oesophageal and bronchial aspiration of gastric content in patients carrying a nasogastric tube and receiving enteral nutrition during mechanical ventilation. Although the method was found to be safe when applied for 8 h, longer times should be considered with caution.

  20. Parents' attitudes toward oral rehydration therapy in children with mild-to-moderate dehydration.

    PubMed

    Nir, Vered; Nadir, Erez; Schechter, Yaffa; Kline-Kremer, Adi

    2013-01-01

    According to current guidelines, the first line of treatment for mild-to-moderate dehydration is oral rehydration; the second line is rehydration through a nasogastric tube. Both methods are widely underused. This study was conducted to evaluate parents' attitudes towards rehydration methods used in pediatric emergency departments. 100 questionnaires were distributed to parents of children who visited emergency room due to gastroenteritis and suspected dehydration. 75 of the parents expected their child to get IV fluids. 49 of them would refuse to consider oral rehydration. 75 of the parents would refuse to consider insertion of nasogastric tube. Parents whose children were previously treated intravenously tended to be less likely to agree to oral treatment. Parents were more prone to decline oral rehydration if the main measurement of dehydration was the child's clinical appearance, clinical appearance with vomiting, or child's refusal to drink and were more likely to agree if the main measurement was diarrhea, diarrhea with clinical appearance, or clinical personnel opinion. This is the first study to examine parents' expectations. We found that in the majority of cases, parents' expectations contradict current guidelines. Efforts should be taken to educate parents in order to allow full implementation of the guidelines.