Sample records for nasolacrimal duct intubation

  1. Balloon catheter dilation and nasolacrimal duct intubation for treatment of nasolacrimal duct obstruction after failed probing.

    PubMed

    Repka, Michael X; Chandler, Danielle L; Holmes, Jonathan M; Hoover, Darren L; Morse, Christine L; Schloff, Susan; Silbert, David I; Tien, D Robbins

    2009-05-01

    To compare the outcomes of balloon catheter dilation and nasolacrimal intubation as treatment for congenital nasolacrimal duct obstruction after failed probing in children younger than 4 years. We conducted a prospective, nonrandomized, multicenter study that enrolled 159 children aged 6 months to younger than 48 months who had a history of a single failed nasolacrimal duct probing and at least 1 of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, or increased tear lake. One hundred ninety-nine eyes underwent either balloon catheter nasolacrimal duct dilation or nasolacrimal duct intubation. Treatment success was defined as absence of epiphora, mucous discharge, or increased tear lake at the outcome visit 6 months after surgery. Treatment success was reported in 65 of 84 eyes (77%; 95% confidence interval, 65%-85%) in the balloon catheter dilation group compared with 72 of 88 eyes (84% after adjustment for intereye correlation; 74%-91%) in the nasolacrimal intubation group (risk ratio for success for intubation vs balloon dilation, 1.08; 0.95-1.22). Both balloon catheter dilation and nasolacrimal duct intubation alleviate the clinical signs of persistent nasolacrimal duct obstruction in a similar percentage of patients.

  2. Change in quality of life of patients undergoing silicone stent intubation for nasolacrimal duct stenosis combined with dry eye syndrome.

    PubMed

    Oh, Jong Rok; Chang, Jee Ho; Yoon, Jin Sook; Jang, Sun Young

    2015-11-01

    To investigate the effect of silicone stent intubation (SI) on the quality of life of patients diagnosed with nasolacrimal duct stenosis and dry eye syndrome. This study is a prospective, interventional case series. Consecutive 30 patients diagnosed with nasolacrimal duct stenosis and reflex tearing due to dry eye syndrome were included. Eligible subjects underwent SI and were asked to complete the Glasgow Benefit Inventory (GBI) questionnaire. Surgical outcomes and GBI scores were investigated 6 months postoperatively. The surgical success rate determined by the patients' subjective symptoms was 76.7% (23/30). Mean total GBI score was +17.19 (95% CI 8.34 to 26.03). The general subscale score was +20.36 (95% CI 10.19 to 30.54), the social support scale score was +21.54 (95% CI 11.37 to 31.71) and the physical health score was -0.56 (95% CI -8.92 to 7.80). SI could be an effective treatment option for reflex tearing in patients diagnosed with dry eye syndrome and nasolacrimal duct stenosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Transcanalicular Laser-Assisted Dacryocystorhinostomy With Endonasal Augmentation in Primary Nasolacrimal Duct Obstruction: Our Experience.

    PubMed

    Goel, Ruchi; Nagpal, Smriti; Kumar, Sushil; Meher, Ravi; Kamal, Saurabh; Garg, Sonam

    To evaluate and compare the success rate of transcanalicular laser-assisted dacryocystorhinostomy with endonasal augmentation, with and without intubation, in patients suffering from primary acquired nasolacrimal duct obstruction, at 1 year of follow up. A prospective, randomized interventional pilot study was conducted at a tertiary care center, in accordance with the guidelines of Declaration of Helsinki. Sixty eyes of 60 adult patients with primary acquired nasolacrimal duct obstruction were included. The participants were divided randomly into 2 equal groups (A and B-without and with bicanalicular intubation, respectively). An osteotomy was first created using 980 nm diode laser (set at 8W continuous mode) transcanalicularly and then enlarged intranasally using Blakesley's nasal forceps, followed by bicanalicular silicon intubation in group B patients. The tubes were removed at the end of 8 weeks. The ostium size was assessed endoscopically at 8 weeks and again at the end of follow up, at 1 year. A successful outcome was defined in terms of ostium patency at the end of 1 year. The results were analyzed at the end of a follow up of 1 year, using various statistical tests (p < 0.05). The mean age of the patients was 35.3 ± 15.89 years, with 23 male and 37 female patients, the 2 groups having a similar male:female ratio. An overall success rate of 90% was achieved at the end of 1 year with no statistically significant difference between the groups. Postoperative complications like tube displacement and punctal, canalicular injury were more in the intubated group. The average osteotomy size was 8.06 ± 5.4 mm at the end of 1 year. Transcanalicular laser-assisted dacryocysto rhinostomy, with endonasal augmentation, is a scarless, effective, daycare procedure, for treatment of primary acquired nasolacrimal duct obstruction with no additional advantage offered by silicone intubation.

  4. Endoscopic endonasal dacryocystorhinostomy with ostial stent intubation following nasolacrimal duct stent incarceration.

    PubMed

    Wang, Xiaopeng; Bian, Yang; Yan, Wentao; Daniel, Pelaez; Tu, Yunhai; Wu, Wencan

    2015-01-01

    To study the feasibility of endoscopic endonasal dacryocystorhinostomy (EE-DCR) with novel lacrimal ostial stent (LOS) intubation for patients with chronic dacryocystitis with incarceration of a previously implanted nasolacrimal duct stent (NDS). According to surgical procedure, 166 patients (167 eyes) were divided into two groups: EE-DCR with LOS intubation was performed on 126 patients (127 eyes) in the EE-DCR group; while external dacryocystorhinostomy (E-DCR) with silicone tube intubation was performed on 40 patients (40 eyes) in the E-DCR group. The LOS or silicone tube was retained for 3-6 months. All patients were followed up for 12-36 months. Success rate of tear drainage reconstruction (TDR) and complications were retrospectively compared. Excluding patients with early detachment of the LOS or the silicone tube, or with incomplete follow-up period, 117 patients (117 eyes) in the EE-DCR group and 36 patients (36 eyes) in the E-DCR group were included. The mean surgical time was 45.8 ± 11.5 min in the EE-DCR group and 68.1 ± 23.8 min in the E-DCR group (p < 0.001). Intraoperatively, the lacrimal sac was observed to become very small and its walls were thin, hyperemic and fragile, firmly attaching to the NDS by fibrous bands in all eyes. Upon final review, success rate of TDR was 83.8% (98/117) in the EE-DCR group, while 58.3% (21/36) in the E-DCR group (p < 0.01). Failure of TDR due to ostial closure by excessive fibrosis occurred in 14 out of 19 patients in the EE-DCR group, significantly less than the 11 out of 15 patients with failed TDR in the E-DCR group (χ(2 )= 6.959, p < 0.01). No significant difference existed in failures due to granuloma occluding the ostium or common canaliculus obstruction. EE-DCR with LOS intubation may be an effective procedure to manage the special subgroup of patients with chronic dacryocystitis with incarcerations of a previously implanted NDS.

  5. An isolated nasolacrimal duct osteoma.

    PubMed

    Kim, Joo Yeon; Kwon, Jae Hwan

    2013-07-01

    Osteomas of the nose and paranasal sinus are common benign tumors that can extend to surrounding structures and result in orbital or intracranial involvement. Presenting symptoms include facial pain, headache, cerebral symptoms, ocular symptoms, and so on, depending on the location and size of the tumor. They commonly occur within the frontal, ethmoid, maxillary, and sphenoid sinuses; however, there are rare cases of reported osteomas in the nasal cavity, turbinate, or orbit. Our case report describes a patient with nasolacrimal duct osteoma who presented with ipsilateral ocular pain, epiphora, and medial canthal swelling. We performed intranasal dacryocystorhinostomy using a nasal endoscope and removed the lacrimal duct osteoma. This report describes symptoms and management of an isolated nasolacrimal duct stone with a review of the literature.

  6. Endoscopic medial maxillectomy with preservation of inferior turbinate and nasolacrimal duct.

    PubMed

    Nakayama, Tsuguhisa; Asaka, Daiya; Okushi, Tetsushi; Yoshikawa, Mamoru; Moriyama, Hiroshi; Otori, Nobuyoshi

    2012-01-01

    Endoscopic medial maxillectomy (EMM) is a safe and effective procedure for treatment of inverted papilloma (IP) originating from the maxillary sinus. However, EMM usually removes the inferior turbinate and nasolacrimal duct. The inferior turbinate has a critical function in conditioning of the nasal airflow, and resection of the nasolacrimal ducts has a risk of epiphora. We developed a newly derived surgical technique, endoscopic modified medial maxillectomy (EMMM), which enables preservation of the inferior turbinate and nasolacrimal duct. A retrospective case series of six patients with IP and nine patients with mucoceles of the maxillary sinus after a Caldwell-Luc operation, who underwent surgery using the EMMM technique, were reviewed. In patients with IP, there were no recurrences for a mean follow-up of 16.7 months. Eight of nine patients with mucoceles of the maxillary sinus showed patency. All patients showed preservation of the inferior turbinate. One patient with mucocele was referred for dacryocystorhinostomy because of epiphora. EMMM produces access to the maxillary sinus identically to conventional EMM, despite preservation of the inferior turbinate and nasolacrimal duct.

  7. Office probing for treatment of nasolacrimal duct obstruction in infants.

    PubMed

    Miller, Aaron M; Chandler, Danielle L; Repka, Michael X; Hoover, Darren L; Lee, Katherine A; Melia, Michele; Rychwalski, Paul J; Silbert, David I; Beck, Roy W; Crouch, Eric R; Donahue, Sean; Holmes, Jonathan M; Quinn, Graham E; Sala, Nick A; Schloff, Susan; Wallace, David K; Foster, Nicole C; Frick, Kevin D; Golden, Richard P; Lambert, Scott R; Tien, D Robbins; Weakley, David R

    2014-02-01

    To determine whether demographic or clinical factors are associated with the outcome of office-based nasolacrimal duct probing for the treatment of congenital nasolacrimal duct obstruction (NLDO). In two multicenter prospective studies, 384 eyes of 304 children aged 6 to <15 months with NLDO underwent a nasolacrimal duct probing performed in the office using topical anesthesia. Treatment success, defined as no clinical signs of NLDO (epiphora, increased tear lake, or mucous discharge) and no reoperation, was assessed 1 month after probing in one study and 6 months after probing in the other study. Data from both studies were pooled to evaluate associations between baseline characteristics and treatment success. Office probing was successful in 75% of eyes overall (95% CI, 70%-80%). The procedure was less successful in eyes of children with bilateral NLDO compared with unilateral NLDO (63% vs 80%; relative risk = 0.78 [95% CI, 0.66-0.92]) and in eyes that had 2 or 3 clinical signs of NLDO compared with one (71% vs 83%; relative risk = 0.88 [95% CI, 0.81-0.96]). Treatment success did not appear to be related to age, specific clinical signs of NLDO, prior treatment, or research study. Performing nasolacrimal duct probing in the office successfully treats NLDO in the majority of cases in children aged 6 to <15 months. The success rate is lower with bilateral disease or when more than one clinical sign of NLDO is present. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  8. Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilhelm, K.E., E-mail: wilhelm@uni-bonn.de; Grabolle, B.; Urbach, H.

    2006-10-15

    The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted withoutmore » major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency.« less

  9. Iodine-131 Therapy and Nasolacrimal Duct Obstructions: What We Know and What We Need to Know.

    PubMed

    Ali, Mohammad Javed

    2016-01-01

    The aims of the current review are to summarize the etiopathogenesis, symptomatology, management, complications, and outcomes of iodine-131-induced nasolacrimal duct obstructions, to propose a screening protocol and elucidate the potential avenues of future research. The authors performed an electronic database (PubMed, MEDLINE, EMBASE, and Cochrane Library) search of all articles published in English on nasolacrimal duct obstructions following radioiodine therapy. These articles were reviewed along with their relevant cross references. Data reviewed included demographics, presentations, investigations, management, complications, and outcomes. In addition, based on relevant unanswered questions and current lacunae in literature, potential avenues for further research have been elucidated. The frequency of nasolacrimal duct obstruction is reported to range from 2.2% to 18% following I-131 therapy. They are mostly bilateral and noted in patients who receive more than 150 mCi radioiodine. Exact etiopathogenesis is unknown but radiotoxicity to lacrimal sac and nasolacrimal duct is believed to be mediated through a sodium-iodine symporter protein. Although uncommon, it is important to increase awareness among treating physicians and patients receiving radioiodine therapy about the potential side effect of nasolacrimal duct obstruction. Imaging modalities are useful adjuncts in the diagnosis. Dacryocystorhinostomy is the most common modality of management with good outcomes. Nasolacrimal duct obstruction following radioiodine treatment is a distinct clinical entity. Increased awareness would facilitate timely diagnosis, management, and an enhanced quality of life for the patients.

  10. Lymphoepithelial Carcinoma of the Nasolacrimal Duct: Clinical, Radiologic, and Immunopathologic Features.

    PubMed

    Jakobiec, Frederick A; Stagner, Anna M; Rubin, Peter A D

    Undifferentiated lymphoepithelial carcinoma (exhibiting both begin lymphoid and malignant epithelial components) most commonly arises in the head and neck, especially in the nasopharynx. It may also be encountered in various ocular adnexal sites, including the nasolacrimal duct. A 63-year-old woman developed a swelling in the region of the right lacrimal sac accompanied by epiphora. CT scanning revealed an enlargement of the nasolacrimal duct from the lacrimal sac to the inferior nasal meatus. A biopsy during dacryocystorhinostomy for symptomatic epiphora revealed hypercellular sheets of small lymphocytes which were interpreted as evidence for a chronic dacryocystitis. Two years later the subtotally excised lesion had substantially grown in size. Repeat CT scans demonstrated an inferonasal anterior orbital mass with further enlargement of the nasolacrimal duct with a solid mass in its lumen, and bone erosion. The biopsy combined a rich background of lymphocytes within which were clusters of undifferentiated carcinoma cells that were cytokeratin and p63 positive. Critical review of the earlier biopsy led to the detection of the same cells, but in smaller numbers, that had been overlooked. An awareness of the possibility of lymphoepithelial carcinoma of the lacrimal sac/duct should improve diagnostic accuracy with the aid of immunohistochemistry. Radiation therapy is often successful in managing this highly sensitive malignant tumor.

  11. Surgical treatment of recurrent dacryocystitis secondary to cystic dilatation of the nasolacrimal duct in a dog.

    PubMed

    Lussier, Bertrand; Carrier, Michel

    2004-01-01

    A 3-year-old, castrated male golden retriever was presented for evaluation of recurrent ocular discharge of 4 months' duration from the left eye. Dacryocystorhinography was performed and demarcated a cystic dilatation of the left nasolacrimal duct with obstruction of the duct distal to the cystic cavity. Surgical exploration of the left maxillary sinus was performed to confirm the diagnosis and reestablish drainage into the nasal cavity. Recovery was uneventful, and the dog has been asymptomatic for >36 months postoperatively. This report documents the third published case of surgical treatment for cystic dilatation of the nasolacrimal duct.

  12. Bloody tears and recurrent nasolacrimal duct obstruction due to a retained silicone stent.

    PubMed

    Kemp, Pavlina S; Allen, Richard C

    2014-06-01

    A 6-year-old girl with a history of bilateral nasolacrimal duct obstruction presented with recurrent tearing, discharge, and bloody tears from the right eye. The patient had a history of multiple prior probing and stenting procedures on the right nasolacrimal system. Endoscopic dacryocystorhinotomy revealed a retained portion of a prior stent and accompanying pyogenic granuloma, removal of which resolved her symptoms. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  13. Transection of Nasolacrimal Duct in Endoscopic Medial Maxillectomy: Implication on Epiphora.

    PubMed

    Imre, Abdulkadir; Imre, Seher Saritepe; Pinar, Ercan; Ozkul, Yilmaz; Songu, Murat; Ece, Ahmet Ata; Aladag, Ibrahim

    2015-10-01

    Management of the nasolacrimal system is usually recommended during medial maxillectomy via external approach because of reported higher rates of postoperative epiphora. Association of the endoscopic medial maxillectomy (EMM) with epiphora, however, is not clearly stated. In this study, we attempted to evaluate whether patients develop epiphora after simple transection of the nasolacrimal duct during EMM. Medical records of 26 patients who underwent endoscopic tumor resection for inverted papilloma (IP) were retrospectively reviewed. Patients who underwent EMM with nasolacrimal canal transection were included and recalled for lacrimal system evaluation. Twelve patients were eligible for inclusion and fluorescein dye disappearance test (FDDT) was performed for each patient. Patient demographics, tumor data, surgical procedures, and follow-up time were recorded. Of the 12 patients included in the study, 6 underwent canine fossa transantral approach concurrently with EMM. The mean duration of follow-up was 21.1 months (range, 6-84 months). Eight patients were graded as 0, whereas 4 patients were graded as 1 according to FDDT. All test results were interpreted as negative for epiphora. All patients were completely symptom free of epiphora. Epiphora after EMM with nasolacrimal canal transection among patients with sinonasal tumors appears to be uncommon. Therefore, prophylactic concurrent management of nasolacrimal system including stenting, dacryocystorhinostomy (DCR), or postoperative lacrimal lavage are not mandatory for all patients.

  14. Probing of congenital nasolacrimal duct obstruction with dacryoendoscope

    PubMed Central

    Kato, Kumiko; Matsunaga, Koichi; Takashima, Yuko; Kondo, Mineo

    2014-01-01

    Background A congenital nasolacrimal duct obstruction (CNLDO) is a relatively common disease in infants. We evaluated the results of probing three patients with CNLDO, under direct view, with a dacryoendoscope. Methods Three cases of CNLDO were examined and treated by probing with a dacryoendoscope, under intravenous anesthesia. The diameter of the dacryoendoscope probe was 0.7 mm, and we were able to observe the inner walls of the lacrimal duct and able to guide the probe through the duct. Results In all cases, the site of obstruction was detected, and the probe was used to remove the obstruction. At 2 weeks after the removal of the obstruction, there was no epiphora or mucopurulent discharge in any of the cases. No complications were detected intra- and postoperatively. Conclusion Although only three cases were studied, we believe that probing with a dacryoendoscope is a safe and effective method of treating a CNLDO. More cases need to be studied. PMID:24876765

  15. Endocanalicular diode laser dacryocystorhinostomy for nasolacrimal duct obstruction: short-term results of a new minimally invasive surgical technique.

    PubMed

    Özçimen, Muammer; Uysal, Ismail Onder; Eryılmaz, Mehmet Akif; Kal, Ali

    2010-11-01

    To evaluate the results, complications, effectiveness, and operative results of the endocanalicular laser dacryocystorhinostomy (ECL DCR) in the distal obstructions of the lacrimal drainage system. Sixty eyes of 57 patients who had a diagnosis of distal obstruction of the lacrimal drainage system were evaluated retrospectively in this study. All patients underwent ECL DCR by diode laser between October 2008 and July 2009. Forty-nine patients (86%) were females, 8 patients (14%) were males, and age distribution was between 3 and 84 years old (median, 40 y). The canaliculi were intubated by a silicone tube. The patency of the nasolacrimal system was controlled by lacrimal lavage, loss of epiphora, and endoscopic evaluation of the endonasal rhinostomy site with routine follow-up scheduled at first day and 1-week, 1-month, and 3-month postoperative intervals. After the 60 ECL DCRs, 10 patients underwent revision ECL DCR because of the persistent epiphora. The patency of the nasolacrimal duct or the decrease of the symptoms was assigned as success. There were no symptoms at all in 83.3% of the patients. The ECL DCR in the treatment of the distal obstructions of the lacrimal drainage system was easily tolerated by the patients, cosmetically preferred because there was no incision and scar formation with high success rates, and a minimally invasive alternative technique.

  16. Minimally invasive medial maxillectomy and the position of nasolacrimal duct: the CT study.

    PubMed

    Sieskiewicz, Andrzej; Buczko, Krzysztof; Janica, Jacek; Lukasiewicz, Adam; Lebkowska, Urszula; Piszczatowski, Bartosz; Olszewska, Ewa

    2017-03-01

    Several minimally invasive modifications of endoscopic medial maxillectomy have been proposed recently, with the least traumatic techniques utilizing the lacrimal recess as a route to enter the sinus. The aim of the study was to analyze the anatomy of medial maxillary wall in the region of nasolacrimal canal and, thus, to determine the capability of performing minimally invasive approach to the maxillary sinus leading through the lacrimal recess. The course of nasolacrimal canal and the distance between the anterior maxillary wall and the nasolacrimal canal (the width of lacrimal recess) were evaluated in 125 randomly selected computed tomography (CT) head examinations. The proportion of cases with unfavorable anatomical conditions (lacrimal recess too narrow to accept a 4 mm optic) to perform minimally invasive middle maxillectomy was assessed. The width of lacrimal recess, measured at the level of the inferior turbinate attachment, varied between 0 and 15.2 mm and was related to slanted course of nasolacrimal canal. The more perpendicular the axis of the canal to the nasal flor, the narrower the lacrimal recess. In about 16% of cases, lacrimal recess width was less than 4 mm and in 14.4% it was missing. The endoscopic approach to maxillary sinus leading through lacrimal recess is possible in about 70% of patients. In the remaining group of patients when the lacrimal recess is too narrow, this type of approach may be difficult to perform without damaging the piriform aperture rim or bony framework of nasolacrimal duct, or it may be impracticable when lacrimal recess is missing.

  17. Intubation of the ostium and nasolacrimal duct with a single self-linking silicone stent in external dacryocystorhinostomy.

    PubMed

    Hui, Jennifer I; Shriver, Erin M; Tse, David T

    2011-01-01

    To describe a stent placement method that eliminates stent prolapse in external dacryocystorhinostomy. A retrospective, institutional review board- approved case series of patients undergoing external dacryocystorhinostomy with an alternative stenting method. Following anastomosis of the posterior flaps, one arm of a Crawford silicone stent is passed through each canaliculus. Both arms are then passed through the nasolacrimal duct and retrieved in the inferior meatus. The 2 distal arms are redirected in the nose; one arm is looped around the proximal portions within the lacrimal sac and tied to the second arm. The stent is self-linked around the inferior turbinate. Nine patients underwent external dacryocystorhinostomy with alternative stenting. None experienced postoperative stent prolapse. At last follow-up (average, 38 months; range, 5-102 months), 8 patients reported resolution of tearing and exhibited normal dye clearance. On compression of the lacrimal sac, none of these 8 patients exhibited reflux of stagnant tears or dye through the canaliculi. This alternative method improves stent retention by using the inferior turbinate as a stopper to eliminate stent prolapse. The self-linking nature obviates the need and expense of additional biomedical devices.

  18. The Association of Neonatal Dacryocystoceles and Infantile Dacryocystitis with Nasolacrimal Duct Cysts (An American Ophthalmological Society Thesis)

    PubMed Central

    Lueder, Gregg T.

    2012-01-01

    Purpose: To investigate whether neonatal dacryocystoceles and dacryocystitis are associated with nasolacrimal duct cysts, and to report the outcomes of treatment of these disorders. Methods: This was a retrospective medical record review of two groups of infants with nasolacrimal duct (NLD) obstruction. The first group had dacryocystoceles with or without dacryocystitis. The second group had NLD obstruction with symptoms severe enough to require early NLD probing. All of the patients underwent NLD probing and nasal endoscopy. When present, NLD cysts were removed. Results: In the first group, 33 infants had dacryocystoceles. Acute dacryocystitis was present in 16 patients, 12 had noninfected dacryocystoceles that did not resolve, and 5 had dacryocystoceles that resolved but severe symptoms persisted. All of the patients had NLD cysts that were surgically removed. The symptoms resolved after surgery in 31 patients (94%). In the second group, 27 infants less than 6 months old without dacryocystoceles underwent early NLD probing and endoscopy due to severity of symptoms. Twelve (44%) of these patients had NLD cysts. The symptoms resolved in 11 (92%) of 12 patients following NLD probing and cyst removal. Conclusions: Neonatal dacryocystoceles are almost always associated with NLD cysts. The success rate of NLD probing and endoscopic cyst removal in these patients is excellent. Nasolacrimal duct cysts also are present in many young infants with severe symptoms of NLD obstruction. Nasal endoscopy is an important adjunct to the management of these infants. PMID:23818736

  19. Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction.

    PubMed

    Mor, Joel M; Guo, Yongwei; Koch, Konrad R; Heindl, Ludwig M

    2017-10-13

    Today's gold standard in the treatment of infrasaccal primary acquired nasolacrimal duct obstruction (PANDO) is external dacryocystorhinostomy (DCR), a relatively invasive procedure that can be performed after failure of recanalizing treatments. However, with progress in the field of diode laser technology, new approaches have emerged. Laser-assisted transcanalicular DCR with subsequent bicanalicular silicon intubation is a new option showing great promise as a viable minimally invasive procedure. Under permanent endoscopic visual control from the nasal cavity, a diode laser fiber is inserted into the lacrimal sac and laser energy is applied to create a bony ostium between the lacrimal sac and the nasal cavity. Since no skin incision needs to be made, advantages of this method comprise the sparing of the skin as well as the medial palpebral structures and the physiological palpebral-canalicular pump mechanism. The duration of surgery as well as reconvalescence is generally shorter than with external DCR. Complications include silicon tube prolapse, mild swelling and, rarely, canalicular infection and thermal injury. One-year functional success rates, defined as complete resolution of symptoms and ostium patency, are high, yet still range behind those of external DCR. However, secondary external DCR after failure of laser-assisted DCR can be performed without difficulty. Thus, laser-assisted transcanalicular DCR is a valid option that should be considered as a second-step procedure after failure of recanalization procedures and before external DCR.

  20. Morphometric Measurements of Bony Nasolacrimal Canal in Children.

    PubMed

    Ela, Araz Server; Cigdem, Kalaycik Ertugay; Karagoz, Yesim; Yigit, Ozgur; Longur, Ecem Sevim

    2018-05-01

    Morphology and dimensions of the bony nasolacrimal canal duct (BNLD) as a key factor in the development of primary acquired nasolacrimal duct obstruction. We aimed to obtain detailed morphometric analysis of BNLD in children without nasolacrimal duct pathology by using computed tomography and provide standard measurements by means of age which could be utilized in planning management or in invasive interventions. Picture Archiving Communication Systems database of our hospital's radiology department was searched for this retrospective study. Subjects were under 18 years of age who had undergone a paranasal, maxillofacial, or temporal bone high-resolution computed tomography scan in last 2 years with various indications. Those with fractures including facial bones and/or nasolacrimal canal or history of nasolacrimal duct pathology were excluded from the study. We measured the diameter, angle, and surface area of BNLD. A total number of 136 subjects (86 boys, 50 girls) were included in the study. The average age was 7.3 ± 5.1 years. We documented statistically significantly positive correlation between all measured diameters and ages (P < 0.001), whereas there was a negative association between mean angle and age (P < 0.001). Mean angle is defined as the angle between BNLD and nasal floor. The surface area of BNLD was found to be significantly increasing depending on age (P < 0.001). However, we could not find any significant association between gender and measured parameters (P > 0.050). Our study demonstrated that development of BNLD continues during childhood, regardless of gender.

  1. Outcomes in children with nasolacrimal duct obstruction: Significance of persistent symptoms while stents are in place.

    PubMed

    Espinoza, Gabriela M; Lueder, Gregg T

    2007-04-01

    To evaluate the correlation between persistent symptoms while stents are in place and final outcome in children with nasolacrimal duct obstruction (NLDO). A retrospective observational case series, with medical record review that included indications for surgery, surgical procedure, presence of symptoms while stents were in place, and final outcome after stent removal. Twenty-eight children with NLDO had nasolacrimal duct stents placed in 42 eyes. Twenty-one of the 42 eyes (50%) had minimal or no signs or symptoms of NLDO while stents were in place, and 18 of 21 (86%) were symptom-free after stent removal. Twenty-one of the 42 eyes (50%) remained symptomatic while stents were in place. Eleven of these 21 eyes (52%) had good outcomes after stent removal. Ten (48%) of these patients had persistent symptoms after stent removal requiring further treatment. The prognosis for a good outcome is excellent if symptoms of NLDO resolve while stents are in place. The prognosis is poorer if symptoms of NLDO persist, but more than half of such patients still have good outcomes. Careful counseling of parents regarding these outcomes should be performed before considering additional interventions.

  2. Nasolacrimal duct obstruction: Does it really increase the risk of amblyopia in children?

    PubMed

    Ramkumar, V Akila; Agarkar, Sumita; Mukherjee, Bipasha

    2016-07-01

    To report the prevalence of amblyopia risk factors in children with congenital nasolacrimal duct obstruction. A retrospective review of records of children with the diagnosis of congenital nasolacrimal duct obstruction (NLDO), who underwent probing from January 2009 to October 2011, was done. All of them underwent a complete ophthalmic evaluation including cycloplegic refraction and strabismus evaluation before probing. A total of 142 children were included in this study. The mean age at presentation was 22.38 months (sample standard deviation (SSD) - 15.88). Amblyopia risk factors were defined according to two sets of guidelines: The American Association for Pediatric Ophthalmology and Strabismus (AAPOS) referral criteria guidelines and the new AAPOS Vision Screening Committee guidelines. Twenty-eight (20%) children were found to have some form of amblyopia risk factor based on the referral criteria prescribed by AAPOS. However, on applying modified guidelines described by Donahue et al., to analyze the same cohort, 21 children were found to have amblyogenic risk factors. Of these 28 children, 13 had significant astigmatism (>1.50 D), 8 children had hypermetropia (>3.50 D), and six children had anisometropia (>1.50 D). One child had significant cataract (media opacity >1 mm). None of the children in this series had either myopia or strabismus. Prevalence of amblyopia risk factor was found to be 20% in our study based on the older guidelines; however, it reduces to 14.78% by applying the modified guidelines. Despite this reduction, importance of a comprehensive ophthalmic examination including cycloplegic refraction in all children presenting with NLDO cannot be overstated. A close follow-up of these children is also essential to prevent the development of amblyopia.

  3. Videoreflective dacryomeniscometry in normal adults and in patients with functional or primary acquired nasolacrimal duct obstruction.

    PubMed

    Francis, Ian C; Chan, Derek G; Papalkar, Daya; Papas, Eric B; Stapleton, Fiona

    2005-03-01

    Videoreflective dacryomeniscometry (VRD) for evaluation of marginal tear film has not been performed in patients with watery eye or in a controlled study. We used VRD to evaluate the height of the central marginal lower lid tear film in normal adults and compared it with two watery-eye groups and a postoperative dacryocystorhinostomy (DCR) group. Case-controlled interventional case series. We evaluated with VRD 20 subjects with normal lacrimal drainage function, 21 patients with primary acquired nasolacrimal duct obstruction (PANDO), 28 patients with functional nasolacrimal duct obstruction (FNLDO), and a postoperative group of 14 patients derived from the previous two pathologic groups. Comparison between the four groups was performed to determine statistically significant differences between tear film height. PANDO and FNLDO groups were shown to have significantly greater median tear meniscus heights ([TMH] PANDO: 620 microm, interquartile range [IQR] 453 microm; FNLDO: 731 microm, IQR 529 microm) than normal subjects (296 microm, IQR 214 microm; P < .001) and postoperative PANDO patients (265 microm, IQR 159 microm). There was no significant difference in TMH between PANDO and FNLDO groups preoperatively (P = .275). There was a reduction in median TMH postoperatively of 355 microm (P = .008) in PANDO and 360 microm (P = .068) in FNLDO. PANDO and FNLDO patients have similar preoperative TMH. In both these groups, TMH is significantly greater than in normal control subjects. Lacrimal drainage surgery substantially reduces TMH as measured using VRD in PANDO.

  4. Use of adjunctive mitomycin C in external dacryocystorhinostomy surgery compared with surgery alone in patients with nasolacrimal duct obstruction: A prospective, double-masked, randomized, controlled trial.

    PubMed

    Ari, Seyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Caca, Ihsan

    2009-08-01

    The most common cause for the failure of external dacryocystorhinostomy (DCR) surgery is the formation of granulation tissue at the osteotomy site or common canaliculus. The aims of this study were to assess the efficacy of intraoperative adjunctive mitomycin C (MMC) treatment in external DCR surgery and to compare this procedure with the standard DCR procedure alone in the long term (1 year). In this prospective, double-masked, randomized, controlled trial, patients with primary acquired nasolacrimal duct obstruction were randomized (using a random number table) into 2 groups based on surgical procedure. In the MMC group, intraoperative adjunctive MMC 0.2 mg/mL was applied to the osteotomy site for 30 minutes. The control group underwent standard DCR procedure only. The results of the DCR surgeries were assessed using objective findings (eg, cessation of excessive tearing via nasolacrimal duct irrigation and the improvement in height of tear meniscus) and subjective symptoms (asking patients to describe the degree of tearing improvement). Both the patients and the researchers who were assessing the study outcomes were masked to treatment group. One hundred eyes of 100 Turkish patients were assessed and equally randomized to the MMC (27 women, 23 men; mean [SD] age, 47.0 [7.6] years) and control (26 women, 24 men; mean age, 46.6 [8.8] years) groups. The follow-up period was not significantly different between the MMC and the control groups (13.1 [1.1] vs 13.2 [1.4] months). Significantly more eyes in the MMC group than the control group remained symptom-free throughout the 1-year follow-up period (45/50 [90%] vs 33/50 [66%]; P=0.005). Significantly more patients in the control group than the MMC group had an improvement in symptoms at the 1-year follow-up (8/50 [16%] vs 2/50 [4%] eyes; P=0.005). Based on the patency of the drainage system, the success rate was significantly greater in the MMC group than the control group (48/50 [96%] vs 42/50 [84%]; P=0.005). Based

  5. Use of adjunctive mitomycin C in external dacryocystorhinostomy surgery compared with surgery alone in patients with nasolacrimal duct obstruction: A prospective, double-masked, randomized, controlled trial

    PubMed Central

    Ari, Şeyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Çaca, Îhsan

    2009-01-01

    Background: The most common cause for the failure of external dacryocystorhinostomy (DCR) surgery is the formation of granulation tissue at the osteotomy site or common canaliculus. Objectives: The aims of this study were to assess the efficacy of intraoperative adjunctive mitomycin C (MMC) treatment in external DCR surgery and to compare this procedure with the standard DCR procedure alone in the long term (1 year). Methods: In this prospective, double-masked, randomized, controlled trial, patients with primary acquired nasolacrimal duct obstruction were randomized (using a random number table) into 2 groups based on surgical procedure. In the MMC group, intraoperative adjunctive MMC 0.2 mg/mL was applied to the osteotomy site for 30 minutes. The control group underwent standard DCR procedure only. The results of the DCR surgeries were assessed using objective findings (eg, cessation of excessive tearing via nasolacrimal duct irrigation and the improvement in height of tear meniscus) and subjective symptoms (asking patients to describe the degree of tearing improvement). Both the patients and the researchers who were assessing the study outcomes were masked to treatment group. Results: One hundred eyes of 100 Turkish patients were assessed and equally randomized to the MMC (27 women, 23 men; mean [SD] age, 47.0 [7.6] years) and control (26 women, 24 men; mean age, 46.6 [8.8] years) groups. The follow-up period was not significantly different between the MMC and the control groups (13.1 [1.1] vs 13.2 [1.4] months). Significantly more eyes in the MMC group than the control group remained symptom-free throughout the 1-year follow-up period (45/50 [90%] vs 33/50 [66%]; P=0.005). Significantly more patients in the control group than the MMC group had an improvement in symptoms at the 1-year follow-up (8/50 [16%] vs 2/50 [4%] eyes; P=0.005). Based on the patency of the drainage system, the success rate was significantly greater in the MMC group than the control group

  6. Vision-related quality of life in patients undergoing silicone tube intubation for lacrimal passage obstructions.

    PubMed

    Kabata, Yoshiaki; Goto, Satoshi; Takahashi, Genichiro; Tsuneoka, Hiroshi

    2011-07-01

    To evaluate the changes in vision-related quality of life in patients with lacrimal passage obstructions undergoing silicone tube intubations. Prospective, consecutive, comparative, interventional case series. Forty-five patients with the chief complaint of epiphora diagnosed with complete and unilateral lacrimal passage obstructions were enrolled. Exclusion criteria included history of congenital nasolacrimal stenosis; lacrimal passage obstructions resulting from trauma, tumor, or chemotherapy; previous lacrimal passage surgery; and partial and functional nasolacrimal duct obstructions. Silicone tube intubation using a Nunchaku-style tube was performed under direct visualization with dacryoendoscope in all patients. Operations were considered as successful when the irrigating fluid could pass through the lacrimal passage and the disappearance of dye was observed in dye disappearance test and the patients' epiphora symptoms improved 3 months postoperatively. The 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) was self-administered in all patients preoperatively and 3 months postoperatively. Patients' preoperative and 3-months-postoperative NEI VFQ-25 scores were compared. Operations were successful in 40 patients (89%). Fully completed questionnaires were received from 32 patients (80%). Silicone tube intubation using a Nunchaku-style tube was associated with a significant improvement of the NEI VFQ-25 composite score (P = .0001), ocular pain score (P < .0001), and mental health score (P = .0003). Relief of epiphora by silicone tube intubation using a Nunchaku-style tube treatment significantly improved the vision-related quality of life in patients with lacrimal passage obstructions. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Nasolacrimal obstruction caused by root abscess of the upper canine in a cat.

    PubMed

    Anthony, James M G; Sandmeyer, Lynne S; Laycock, Amanda R

    2010-03-01

    A 10-year-old, castrated male domestic short hair cat was presented to the Small Animal Clinic at the Western College of Veterinary Medicine with a presenting complaint of chronic, ocular discharge from the left eye. Ocular examination confirmed epiphora and mucopurulent discharge but there were no apparent reasons for the ocular discharge, and nasolacrimal obstruction was suspected. The cat had swelling of the left side of the face, severe periodontal disease and a fractured upper left canine tooth with pulpal exposure. Dacryocystorhinography revealed narrowing of the nasolacrimal duct above the root of the fractured upper left canine and dental radiographs showed a severe periapical lucency at the apex of the upper left canine tooth. The fractured canine tooth was removed. Subsequently, the ocular discharge and facial swelling resolved. After 2 years, the epiphora has never reoccurred. This is a noteworthy case because a suspected root abscess resulted in extralumenal compression of the nasolacrimal duct, which shows the importance of a thorough oral examination when nasolacrimal obstruction is evident.

  8. Use of the Crawford tube for symptomatic epiphora without nasolacrimal obstruction.

    PubMed

    Tong, Nyu-Xia; Zhao, Ying-Ying; Jin, Xiu-Ming

    2016-01-01

    To evaluate the effectiveness of the Crawford tube in treating symptomatic epiphora without nasolacrimal obstruction. A protocol was adopted for the management of symptomatic epiphora without nasolacrimal obstruction. Patients who suffered symptomatic epiphora without nasolacrimal obstruction in both eyes were included in the study. One eye was treated with Crawford tube intubation and the other eye was treated with medication therapy. Degree of watering, patient satisfaction, and symptomatic improvement were carefully evaluated by one of the authors at the end of the follow-up period, after Crawford tube removal, to ascertain functional results. Thirty-seven adult patients (37 eyes) underwent Crawford tube intubation for functional epiphora. The mean follow-up time after removal of the tube was 14.8±4.8mo. The procedure was an overall success in 28 eyes (75.7%), with symptoms improving significantly. Two eyes (5.4%) were relieved of indoor epiphora, two (5.4%) had minimal epiphora outdoors, but only with wind or cold, and five (13.5%) continued to experience tearing both indoors and outdoors. Thirty of the patients (81%) expressed satisfaction with the procedure. Crawford tube insertion is an effective, safe, simple, and relatively noninvasive treatment strategy for functional lacrimal system obstruction.

  9. Endoscopic dacryocystorhinostomy with and without silicone intubation: 4 years retrospective study.

    PubMed

    Longari, F; Dehgani Mobaraki, P; Ricci, A L; Lapenna, R; Cagini, C; Ricci, G

    2016-08-01

    The objective of this study is to assess different outcomes between endoscopic dacryocystorhinostomy (En-DCR) with and without silicone intubation. We retrospectively analyzed 84 patients (89 procedures), suffering from chronic epiphora for primary acquired nasolacrimal duct obstruction, treated with En-DCR and divided into two groups depending on silicone stent intubation. The surgical outcomes were evaluated at 7 post-operative controls using Munk's score criteria. Functional success was defined as absence of epiphora, no further episodes of dacryocystitis, and a patent ostium after fluorescein irrigation. 45 En-DCR with stent and 44 En-DCR without stent were performed. Success rate after 18 months follow-up were, respectively, 82.2 % in the stent group and 88.6 % in the non-stent group (OR 0.59) with no statistical differences. The ostial size reduction has been reported in higher percentage in the stent group, mainly due to peristomal granuloma (OR 3.64), scar tissue formation (OR 2.25), and turbinoseptal synaechia (OR 1.76). The benefits of non-intubation are less patient discomfort, reduced surgical time and costs, simpler follow-up regimen and less intubation-associated complications. En-DCR without silicone stent intubation should be the first choice of procedure, stent intubation should be reserved in selected cases with poor local conditions pre and intra-operatively assessed.

  10. Blocked Tear Duct

    MedlinePlus

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  11. Dacryocystitis following a nasolacrimal duct obstruction caused by an ectopic intranasal tooth in a dog.

    PubMed

    Voelter-Ratson, Katrin; Hagen, Regine; Grundmann, Stefan; Spiess, Bernhard Martin

    2015-09-01

    To describe a nasolacrimal duct (NLD) obstruction secondary to an ectopic tooth in a 5-year-old male Border collie. The dog was presented with a 1-month history of mucopurulent discharge from the left eye (OS) preceded by a lifelong history of epiphora OS. Treatment with neomycin/polymyxin B/dexamethasone ophthalmic solution had not improved the clinical signs, and the NLD was not patent when irrigated by the referring veterinarian. A complete ophthalmologic examination was performed followed by dacryocystorhinography and computed tomography (CT). The ophthalmologic examination revealed marked mucopurulent discharge, mild conjunctivitis, slightly elevated STT measurements, and a negative Jones test OS. Both nasolacrimal puncta OS could be cannulated without resistance for approximately 1.5 cm. Upon irrigation, copious amounts of mucopurulent discharge were exited through the corresponding punctum, while no fluid could be detected at the nares. Dacryocystorhinography was performed. Radiographs revealed an ectopic left canine tooth within the left nasal cavity. A cystic dilation of the NLD was observed proximal to the ectopic tooth. Computed tomography was performed to determine the exact position of the tooth and possible involvement of adjacent structures; CT confirmed the previous imaging findings. Treatment with systemic antibiotics, NSAIDs, and ofloxacin ophthalmic solution led to resolution of the clinical signs within several days. Surgery was declined by the owner. This is the first case report describing a blocked NLD due to an ectopic tooth in a dog. Ectopic teeth should be included as a differential diagnosis in cases of dacryocystitis and chronic epiphora in dogs. © 2014 American College of Veterinary Ophthalmologists.

  12. Transitional cell neoplasm of the nasolacrimal duct associated with human papillomavirus type 11.

    PubMed

    Vickers, Jennifer L; Matherne, Ryan J; Allison, Ashley W; Wilkerson, Michael G; Tyring, Stephen K; Bartlett, Brenda L; Rady, Peter L; Kelly, Brent C

    2010-07-01

    Tumors of the lacrimal sac are rare but noteworthy because of their significant potential to become malignant or life-threatening if treatment is delayed. Dermatologists may be the first to encounter such neoplasms. We report a case of a 53-year-old Caucasian woman who presented with a seven-year history of an asymptomatic, subcutaneous nodule near her right medial canthus. Histology of the lesion revealed transitional epithelium in a papillary growth pattern with numerous goblet cells, scattered mitoses and focal full-thickness atypia. The patient was diagnosed with transitional cell neoplasm (inverted papilloma-type) of the nasolacrimal duct. PCR evaluation identified HPV type 11 in the lesion. Our report is one of a growing number of case reports and series detecting HPV DNA in these tumors which further supports HPV as an etiologic agent in epithelial lacrimal sac tumors. We believe that dermatopathologists need to be aware of this entity, as dermatologists may be the first to encounter these neoplasms. The association of HPV with this tumor does not prove causality.

  13. Endoscopic-modified medial maxillectomy and its limitation for a solitary fibrous tumor of the lacrimal sac and nasolacrimal duct.

    PubMed

    Moriyama, Munehito; Kodama, Satoru; Hirano, Takashi; Suzuki, Masashi

    2017-06-01

    Solitary fibrous tumor (SFT) is an uncommon neoplasm that usually arises from the pleura. Recently, SFTs have been reported in the head and neck region located in subsites such as the orbit. SFTs of the lacrimal sac are extremely rare, with only six cases reported in the English literature. We describe a SFT arising from the right lacrimal sac and extending along the nasolacrimal duct into the nasal cavity. Although, the tumor could not be removed by endoscopic-modified medial maxillectomy (EMMM) alone, combined approach with EMMM and a small external incision achieved the complete removal of the tumor. The patient has remained disease-free 24 months after surgery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Efficacy of probing for children with congenital nasolacrimal duct obstruction: a retrospective study using fluorescein dye disappearance test and lacrimal sac echography.

    PubMed

    Steindler, Piero; Mantovani, Enrico; Incorvaia, Carlo; Parmeggiani, Francesco

    2009-06-01

    To evaluate B-scan echography for the assessment of lacrimal sac (LS) in pediatric epiphora secondary to congenital nasolacrimal duct obstruction (CNLDO), and to verify its predictive role in functional efficacy of nasolacrimal duct probing. Thirty-nine eyes of 23 consecutive children, treated with a single probing for persistent CNLDO-related epiphora, were retrospectively studied. These cases were investigated both collectively and considering two sub-groups: group A (ten patients [20 eyes] 13 months. Fluorescein dye disappearance test at 10 minutes (FDDT-10) and ultrasound examination of LS were performed before and after probing. An echographic LS scoring system (grade 0 = no LS enlargement; grade 1 = slight longitudinal LS enlargement; grade 2 = longitudinal and slight transverse LS enlargement; grade 3 = marked longitudinal and transverse LS enlargement) was introduced as a predictor of probing efficacy, estimating FDDT-10 modification between pre- and post-operative checks. Echographic LS evaluation was easily practicable without sedation. In the total cluster and in both age sub-groups, post-probing FDDT-10 decreased with respect to pre-probing value (p < 0.001). Post-probing LS score improved with respect to pre-probing check within the total cluster and group A (p < 0.05). Strong correlation between pre-probing LS alteration and functional probing failure was present in each studied cluster (all p values <0.0001). Within group B, a greater gain of post-probing FDDT-10 was more frequent in patients with a better pre-probing LS score, as well as in younger children (both p values <0.0001). In children with CNLDO-related epiphora, B-scan echography of the LS can represent a reliable and useful examination for a better understanding of the functional prognosis after probing treatment.

  15. Reliability of fluorescein dye disappearance test in assessment of adults with nasolacrimal duct obstruction.

    PubMed

    Kashkouli, Mohsen Bahmani; Mirzajani, Hoora; Jamshidian-Tehrani, Mansooreh; Pakdel, Farzad; Nojomi, Marzieh; Aghaei, Gholam-Hossein

    2013-01-01

    To evaluate the role of fluorescein dye disappearance test (FDDT) in assessment of adults with primary acquired nasolacrimal duct obstruction (PANDO) and its correlation with age and severity of epiphora. In a prospective, cross-sectional comparative study, FDDT at 2 (2-FDDT), 5 (5-FDDT), and 10 (10-FDDT) minutes were performed in 58 eyes of 58 patients with PANDO (case) and 58 eyes of 58 subjects without epiphora (control) between 2008 and 2010. Exclusion criteria were any disease, trauma, or medications that might have an effect on tear drainage system. Patients with functional or incomplete obstruction and upper lacrimal drainage system obstruction were excluded in the case group. FDDT and severity of epiphora were graded. Case and control groups were matched. 2-FDDT showed a sensitivity of 82.8%, specificity of 91.4%, positive predictive value of 90.6%, and negative predictive value of 84.1%. Sensitivity and negative predictive value decreased to 71.1% and 78.6% in 5-FDDT. 5-FDDT specificity and positive predictive value, however, increased to 94.8% and 93.5%, respectively. There was no statistically significant correlation between severity of epiphora and age with FDDT. FDDT is a simple, reliable, and highly specific test in assessment of adults with PANDO.

  16. A survey of management of congenital nasolacrimal duct obstruction by pediatric primary health care providers in Spain.

    PubMed

    Galindo-Ferreiro, Alicia; Palencia-Ercilla, Teresa; Ferreira, Livia Mendoza; Galvez-Ruiz, Alberto; Zornoff, Denise C M; Khandekar, Rajiv; Schellini, Silvana A

    2017-06-26

    To survey the management of congenital nasolacrimal duct obstruction (CNLDO) by pediatric primary health care providers in Spain. This was a descriptive study using a web-based questionnaire to evaluate the perceptions of the members of the Pediatric Primary Care Society in Castilla-León, Spain (APAPCYL), regarding management of CNLDO. The questionnaire contained 14 direct questions and was sent by e-mail to all the pediatricians. All the responses were analyzed by the frequency of occurrence and percentages. Ninety physicians responded to the questionnaire. Massage 2 or 3 times a day was the initial treatment advised by 60.47% of pediatricians. Nearly half of the pediatricians recommended continuing massage until symptoms resolved. Fewer than 50% of children required referral to an ophthalmologist. Reasons for an ophthalmic consult included persistence of symptoms among 87.21% of pediatricians and parental/guardian request among 10.5% of pediatricians. According to 45.6% of pediatricians, their knowledge about CNLDO is limited, and 92.2% would like to receive further training on CNLDO. Massage was the main initial treatment for managing CNLDO among pediatricians. The outcomes of this survey indicated that massage fails in fewer than 50% of patients and an ophthalmic referral is required for these cases.

  17. Microbiology of primary acquired nasolacrimal duct obstruction: simple epiphora, acute dacryocystitis, and chronic dacryocystitis

    PubMed Central

    Pornpanich, Kanograt; Luemsamran, Panitee; Leelaporn, Amornrut; Santisuk, Jiraporn; Tesavibul, Nattaporn; Lertsuwanroj, Buntitar; Vangveeravong, Sumalee

    2016-01-01

    Purpose The aim of this study was to determine the microbiology of primary acquired nasolacrimal duct obstruction (PANDO) and its antimicrobial susceptibilities. Methods Ninety-three patients (100 eyes) diagnosed with PANDO, categorized as acute, chronic dacryocystitis, or simple epiphora, were prospectively enrolled. Lacrimal sac contents were cultured for aerobic and anaerobic bacteria and fungi. Cultured organisms were identified, and antimicrobial susceptibility testing was performed for aerobic bacteria. Results Seventy-nine of the 100 samples were culture positive. One hundred twenty-seven organisms were isolated, and 29 different species were identified. Most microorganisms were Gram-positive bacteria (45 samples or 57.0% of all positive culture samples), whereas Gram-negative bacteria, anaerobic bacteria, and fungi were found in 39 (49.4%), 24 (30.4%), and four samples (5.1%), respectively. The most frequently isolated group was coagulase-negative staphylococci (27.8%), followed by nonspore-forming Gram-positive rods (anaerobe) (17.7%) and Pseudomonas aeruginosa (15.2%). Of the 100 samples, five, 45, and 50 samples were obtained from patients with acute dacryocystitis, chronic dacryocystitis, and simple epiphora, respectively. Subgroup analysis showed that Gram-negative organisms were isolated more frequently from the chronic dacryocystitis subgroup than from the simple epiphora subgroup (P=0.012). Antimicrobial susceptibility testing demonstrated that ciprofloxacin was the most effective drug against all Gram-positive and Gram-negative organisms. Conclusion Patients with PANDO, with or without clinical signs of lacrimal infection, were culture positive. Gram-negative organisms were frequently isolated, which were different from previous studies. Ciprofloxacin was the most effective agent against all Gram-positive and Gram-negative organisms. PMID:26955261

  18. Management of functional epiphora in patients with an anatomically patent dacryocystorhinostomy.

    PubMed

    Shams, Pari N; Chen, Philip G; Wormald, Peter J; Sloan, Brian; Wilcsek, Geoff; McNab, Alan; Selva, Dinesh

    2014-09-01

    Approximately 5% to 10% of patients continue to experience persistent epiphora following an anatomically successful dacryocystorhinostomy (DCR) for nasolacrimal duct obstruction or stenosis. To investigate the management and success rate of so-called "functional failure" of DCR for nasolacrimal duct obstruction by experienced lacrimal surgeons. Multicenter retrospective case series including 5 Australian and New Zealand centers. Participants included 61 patients (71% women [n = 46]; mean age, 66 years) with functional epiphora after 65 DCRs (69% transnasal) who were recruited over a mean of 7.6 years. Inclusion criteria included confirmed preoperative diagnosis of nasolacrimal duct obstruction or stenosis, age greater than 18 years, recurrent or persistent epiphora after DCR, an anatomically successful DCR, and follow-up longer than 6 months. Exclusion criteria included evidence of lacrimal hypersecretion, eyelid malposition, and punctal or canalicular abnormalities. The number, type, timing, and success of all clinical interventions performed for the management of functional epiphora after DCR. Epiphora recurred a mean of 8.9 months after primary DCR; 89% of the cases (n = 58) had evidence of a patent ostium and 100% were patent on lacrimal irrigation. Intubation with a lacrimal stent was performed in 82% of the cases at the time of surgery, and all stents were removed a mean of 8 weeks postoperatively. Epiphora was reported immediately following DCR in 32% (n = 21) of the cases and within 6 weeks after removal of the stent in 31% (n = 20); late recurrence (>12 months after DCR) developed in 37% (n = 24) of the cases. In a total of 15% of the cases, participants declined any treatment following DCR. The remainder underwent a mean of 1.3 interventions (range, 1-3) during a mean of 23 to 41 months after primary DCR, following which 72% (n = 47) of the cases had a successful outcome; 12% (n = 8) failed to achieve improvement, and the patients declined further

  19. Scanning Electron Microscopic Features of Nasolacrimal Silastic Stents Retained for Prolong Durations Following Dacryocystorhinostomy.

    PubMed

    Ali, Mohammad Javed; Baig, Farhana; Lakshman, Mekala; Naik, Milind N

    2016-01-01

    The aims of this study were to examine the scanning electron microscopic features of silastic nasolacrimal duct stents retained for long durations following a dacryocystorhinostomy. A prospective interventional study was performed on stents retrieved from patients who were lost to follow up after a dacryocystorhinostomy with Crawford stent insertion. Long duration was defined as stents retrieved at a minimum of 1 year following a dacryocystorhinostomy. None of the patients had any evidence of postoperative infection. After removal, the stent segments were subjected to biofilm and physical deposit analysis using standard protocols of scanning electron microscopy. These stent segments were compared against sterile stents which acted as controls. A total of 7 stents were studied. Five were consecutive patient samples, and 2 were sterile stents. All the 5 stents were retrieved from patients who were lost to follow up for a minimum of 12 months following surgery. The mean duration of intubation at retrieval was 21 months. All the stents demonstrated evidence of biofilm formation and physical deposits. However, as the duration of retention increased, the deposits and biofilms were noted to be progressively denser, multilayered and extensive. Certain areas demonstrated thick biofilm integration with the deposits. Polymicrobial communities were noted within the exopolysaccharide matrix. This is the first study to exclusively report on scanning electron microscopic features of lacrimal stents retained for long durations. Further studies on physical elements within the deposits and protein analysis would provide more insights into stent-tissue interactions.

  20. Changes in cytokines in tears after endoscopic endonasal dacryocystorhinostomy for primary acquired nasolacrimal duct obstruction.

    PubMed

    Lee, J K; Kim, T H

    2014-05-01

    We attempted to compare the cytokine composition of tears between primary acquired nasolacrimal duct (NLD) obstruction and normal controls. We investigated the changes in cytokines in tears after endoscopic endonasal dacryocystorhinostomy (DCR). Eighteen patients underwent endonasal DCR, with seven patients undergoing bilateral DCR, resulting in twenty-five DCRs in total. Eleven contralateral un-operated eyes were used as normal controls. Silicone stents were removed 3 months after surgery. Tear samples were collected from all eyes before surgery, and at 1 month, 2 months, 3 months, and 4 months after surgery. The level of interleukin (IL)-1β, IL-2, IL-6, IL-10, transforming growth factor (TGF)-β2, fibroblast growth factor (FGF)-2, and vascular endothelial growth factor (VEGF) in the tears was measured. The concentrations of IL-2, IL-6, IL-10, VEGF, and FGF-2 were significantly higher in eyes with NLD obstruction than controls before surgery (P=0.006, 0.018, 0.002, 0.048, and 0.039, respectively). Most inflammatory cytokines (IL-1β, IL-2, IL-6, VEGF, and FGF-2) were higher in the tears of the DCR group compared with the controls during the postoperative follow-up, but then rapidly decreased to the level of the controls after removal of the silicone stent. The recurred eyes showed a higher level of TGF-β2 and FGF-2 in tears compared with the eyes that showed good surgical results (P<0.005 and <0.005, respectively). The tear levels of inflammatory cytokines were higher in eyes with NLD obstruction than controls. The changes in cytokine level during the postoperative period showed the importance of cytokine analysis in understanding wound healing after DCR.

  1. Nasolacrimal duct obstruction following radioactive iodine 131 therapy in differentiated thyroid cancers: review of 19 cases.

    PubMed

    Al-Qahtani, Khalid Hussain; Al Asiri, Mushabbab; Tunio, Mutahir A; Aljohani, Naji J; Bayoumi, Yasser; Munir, Iqbal; AlAyoubi, Ayman

    2014-01-01

    Radioactive iodine 131 ((131)I) therapy has long been used in the treatment of differentiated thyroid cancers (DTC). While salivary and lacrimal glandular complications secondary to (131)I therapy are well documented, there is little in the literature addressing nasolacrimal duct obstruction (NLDO). We aimed to evaluate the frequency of (131)I therapy-acquired NLDO, its correlation to (131)I therapy doses, and the surgical treatment outcome of this rare side effect. From 2000-2012, a retrospective review of 864 among 1,192 patients with confirmed DTC who were treated with (131)I therapy was performed to examine the frequency of NLDO, its causative factors, as well as imaging, surgical intervention, and outcomes. Nineteen (2.2%) patients were identified with NLDO. The mean age was 51.9±10.5 years (range: 39-72 years). Fifteen (78.9%) were female and four were male (21.1%). The mean individual (131)I doses were 311.1±169.3 millicurie (mCi) (range: 150-600 mCi). The mean duration between the date of (131)I therapy and the occurrence of NLDO was 11.6±4.1 months (range: 6.5-20). Fourteen (73.7%) patients had bilateral epiphora. Computed tomography dacryography allowed for the detection of all NLDO. Eighteen (94.7%) patients underwent dacryocystorhinostomy. Complete recovery was obtained in 14 (73.7%) patients. Age >45 years and (131)I therapy doses >150 mCi were significantly correlated with NLDO (P=0.02 and P=0.03, respectively). NLDO is an underestimated complication of (131)I therapy in DTC patients. Clinicians should be aware of this rare complication for prompt intervention.

  2. Comparison of endoscopic and external dacryocystorhinostomy for treatment of primary acquired nasolacrimal duct obstruction

    PubMed Central

    Su, Pei-Yuan

    2018-01-01

    PURPOSE: The purpose of this study is to compare the success rates of endoscopic endonasal dacryocystorhinostomy (EN-DCR) and external DCR (EX-DCR) for the treatment of primary acquired nasolacrimal duct obstruction (PANLDO). DESIGN: This was a retrospective, comparative, nonrandomized clinical study. METHODS: Reviewed medical records of PANLDO underwent DCR at Far-Eastern Memorial Hospital from May 2011 to June 2017. Data regarding the lacrimal passage system, comorbidities, surgical outcomes, and postoperative complications were analyzed. Anatomical success was defined as patency confirmed by intranasal endoscopic inspection of the ostium and successful lacrimal irrigation; functional success was defined as complete resolution of epiphora and positive fluorescein dye disappearance test, which were assessed at postoperative 6th months. RESULTS: One hundred and seventy patients (37 males, 133 females, mean age 57 years) underwent 178 DCR surgeries for PANLDO. The overall anatomical success rate was 94.4% (93.5% in EN-DCR vs. 95.8% in EX-DCR, P = 0.511) and functional success rate was 90.4% (90.7% in EN-DCR and 90.1% in EX-DCR, P = 0.909). Surgical outcomes were comparable between two groups. Complication rate was low in both groups, including 11 cases of early canalicular stent dislodge (7 in EN-DCR, 4 in EX-DCR), one case of postoperative nasal bleeding in EN-DCR, and two skin wound dehiscence and three cutaneous keloid formation in EX-DCR. None of these cases were concluded into surgical failure at the final visit. The time to symptoms relief was statistical significantly shorter in EN-DCR group (1.7 vs. 3.7 weeks in EX-DCR, P < 0.001). CONCLUSIONS: Success rate of DCR for PANLDO in our study was high, and complication rate was low for both endoscopic and external approaches. There was no statistically significant difference between them. EN-DCR provided higher satisfaction due to quicker recovery and lack of external incision. Endoscopic DCR should be considered

  3. The natural process of congenital nasolacrimal duct obstruction and effect of lacrimal sac massage.

    PubMed

    Karti, Omer; Karahan, Eyyup; Acan, Durgul; Kusbeci, Tuncay

    2016-12-01

    This study aimed to examine the rate of symptomatic improvement of congenital nasolacrimal duct obstruction (CNLDO) in infants treated with conservative management within the first year of age. Other purpose of the study is to emphasize the relationship between spontaneous resolution time and effective lacrimal sac massage. Thirty-one infants were diagnosed to have CNLDO by an ophthalmologist prior to 3 months of age. In this study, 36 eyes of 31 patients were included with CNLDO. The patients were divided into two groups. Group 1 (28 eyes of 24 patients) was consisted of the patients who were applied effective lacrimal sac massage regularly during the follow-up period, and patients whose parents did not apply a regular lacrimal passage regularly were accepted as group 2 (8 eyes of 7 patients). Thirty-three eyes of 31 patients (18 rights and 15 left) successfully resolved with only conservative management (91.6 %). In these thirty-three eyes, one eye (3 %) resolved between 0 and 3 months, fourteen eyes (42.5 %) resolved between 4 and 6 months, eleven eyes (33.3 %) resolved between 7 and 9 months, and seven eyes (21.2 %) resolved between 10 and 12 months. CNLDO was resolved in 27 (96.2 %) of 28 eyes in group 1, and in group 2, six eyes (77.7 %) had resolvement. This difference was statistically significant (p = 0.001). The mean age of resolution was 6.8 ± 1.88 months in group 1, 10.3 ± 1.5 months in group 2 (p < 0.001). In light of our study, we believe that conservative management of CNLDO is highly successful. Our study provided a possible objective explanation for the efficacy of lacrimal sac massage. Emphasizing the importance of the massage to parents and describing in detail can reduce the risk of unnecessary surgical interventions.

  4. Successes rate of endoscopic dacryocystorhinostomy at KMC.

    PubMed

    Shrestha, S; Kafle, P K; Pokhrel, S; Maharjan, M; Toran, K C

    2010-01-01

    Nasolacrimal duct obstruction is a common problem which can be corrected by dacryocystorhinostomy (DCR). The gold standard treatment for this is DCR operation through an external approach. Development of endoscopic sinus surgery and endoscopic DCR performed through intranasal route is a major recent development in this field. The aim of this study is to find out the success rate of endoscopic dacryocystorhinostomy without silicon stent intubation within the period of six month following surgery. A prospective study was done on 26 patients with obstruction of the nasolacrimal duct referred from eye out-patient department to ENT OPD during one year period from 2008 to 2009. All the cases had undergone endoscopic DCR operation which was regularly followed up for a period of six months. Postoperative patency of ostium was checked by sac syringing and endoscopic visualisation of ostium in the nasal cavity. The success of surgery was categorised as: complete cure, partial cure and no improvement depending upon symptomatic relief and clinical examination such as sac syringing and endoscopic examination following surgery. In six months' follow-up, 22 (84.5%) out of 26 patients had achieved the complete cure and 4 patients (15.5%) continued to have persistent epiphora. Endoscopic DCR is a beneficial procedure for nasolacrimal duct obstruction with no external scar on face and less bleeding. The success rate is as good as external DCR.

  5. Effect of rebamipide ophthalmic suspension on the success of lacrimal stent intubation.

    PubMed

    Mimura, Masashi; Ueki, Mari; Oku, Hidehiro; Sato, Bunpei; Ikeda, Tsunehiko

    2016-02-01

    To evaluate the effect of the postoperative administration of rebamipide ophthalmic suspension on the success rate of lacrimal stent intubation (LSI) for the treatment of primary acquired nasolacrimal duct obstruction (PANDO). This comparative interventional cohort study investigated 110 consecutive patients with PANDO who were treated with LSI and followed up for 12 months postoperatively at one institution. LSI was performed by one surgeon, and all patients received identical postoperative care. Among the total 110 patients, 71 underwent LSI with postoperative administration of rebamipide ophthalmic suspension, and 39 underwent LSI without administration of the suspension. Data related to patient age, gender, laterality, and postoperative administration of rebamipide ophthalmic suspension were collected and used as independent variables, and logistic regression analyses were performed to compare the anatomical success rate at 12 months postoperatively between patients with and without postoperative administration of the suspension. The anatomical success rate of LSI in patients with and without postoperative administration of rebamipide ophthalmic suspension was 90.1 and 69.2 %, respectively. A comparison of these success rates showed statistical significance, in that the rate of treatment success was higher in PANDO patients who underwent LSI with postoperative administration of the suspension [odds ratio (OR), 3.37; P < 0.05]. The findings of this study show that postoperative administration of rebamipide ophthalmic suspension increases the rate of anatomical success in patients who undergo LSI for the treatment of PANDO.

  6. Pediatric endocanalicular diode laser dacryocystorhinostomy: results of a minimally invasive surgical technique.

    PubMed

    Uysal, Ismail Onder; Ozçimen, Muammer; Yener, Halil Ibrahim; Kal, Ali

    2011-09-01

    The purpose of this study was to evaluate the effectiveness of endocanalicular diode laser dacryocystorhinostomy (DCR), which is a minimally invasive surgical technique, in pediatric patients with congenital nasolacrimal duct obstruction (NLDO). A retrospective study was carried out on patients treated between October 2008 and August 2009 for nasolacrimal duct obstruction with an endocanalicular diode laser procedure. Patients diagnosed as having nasolacrimal duct obstruction were included in this study and an endocanalicular diode laser procedure was performed. The main outcome measures were patients' previous treatments, clinical presentation, operative and postoperative complications, postoperative follow-up and resolution of epiphora. Eighteen children (10 girls, 8 boys) with a mean age of 6.11 ± 2.08 years (range, 4-10) underwent 20 endocanalicular laser DCR operations for congenital NLDO. In all eyes (100%), there was a history of epiphora and chronic dacryocystitis; two (10%) presented with acute dacryocystitis. Previous procedures included probing and irrigation of all eyes (100%) and silicone tube intubation in nine eyes (45%). None of the patients underwent any previous DCR operations. During a mean postoperative follow-up period of 20.50 ± 3.24 months (range, 14-24 months), the anatomical success rate (patency of ostium on nasal endoscopy) was 100%, and the clinical success rate (resolution of epiphora) was 85%. Endocanalicular diode laser DCR is an effective treatment modality for pediatric patients with congenital NLDO that compares favorably with the reported success rates of external and endoscopic endonasal DCR. Moreover, it has an added advantage of shorter operative time, less morbidity and avoidance of overnight admission.

  7. Development of the nasolacrimal apparatus in the Mongolian gerbil (Meriones unguiculatus), with notes on network topology and function.

    PubMed

    Rehorek, Susan J; Cunningham, Jayna; Bruening, Amanda E; Johnson, Jessica L; Bhatnagar, Kunwar P; Smith, Timothy D; Hillenius, Willem J

    2015-09-01

    The nasolacrimal apparatus (NLA) is a multicomponent functional system comprised of multiple orbital glands (up to four larger multicellular exocrine structures), a nasal chemosensory structure (vomeronasal organ: VNO), and a connecting duct (nasolacrimal duct: NLD). Although this system has been described in all tetrapod vertebrate lineages, albeit not always with all three main components present, considerably less is known about its ontogeny. The Mongolian gerbil (Meriones unguiculatus) is a common lab rodent in which the individual components of the adult NLA have been well studied, but as yet nothing is known about the ontogeny of the NLA. In this study, serial sections of 15 fetal and three adult Mongolian gerbil heads show that the development of the NLA falls into three fetal stages: inception (origin of all features), elongation (lengthening of all features), and expansion (widening of all features). No postnatal or juvenile specimens were observed in this study, but considerable growth evidently occurs before the final adult condition is reached. The development of the orbital glands and the VNO in the Mongolian gerbil is largely consistent with those in other mammals, despite a slight nomenclatural conundrum for the anterior orbital glands. However, the Mongolian gerbil NLD follows a more circuitous route than in other tetrapods, due mainly to the convoluted arrangement of the narial cartilages, the development of a pair of enlarged incisors as well as an enlarged infraorbital foramen. The impact of these associated features on the ontogeny and phylogeny of the NLA could be examined through the approach of network science. This approach allows for the incorporation of adaptations to specific lifestyles as potential explanations for the variation observed in the NLA across different tetrapod clades. © 2015 Wiley Periodicals, Inc.

  8. Biofilm Quantification on Nasolacrimal Silastic Stents After Dacryocystorhinostomy.

    PubMed

    Murphy, Jae; Ali, Mohammed Javed; Psaltis, Alkis James

    2015-01-01

    Biofilms are now recognized as potential factors in the pathogenesis of chronic inflammatory and infective diseases. The aim of this study was to examine the presence of biofilms and quantify their biomass on silastic nasolacrimal duct stents inserted after dacryocystorhinostomy (DCR). A prospective study was performed on a series of patients undergoing DCR with O'Donoghue stent insertion. After removal, the stents were subjected to biofilm analysis using standard protocols of confocal laser scanning microscopy (CLSM) and scanning electron microscopy. These stents were compared against negative controls and positive in vitro ones established using Staphylococcus aureus strain ATCC 25923. Biofilm quantification was performed using the COMSTAT2 software and the total biofilm biomass was calculated. A total of nine consecutive patient samples were included in this prospective study. None of the patients had any evidence of postoperative infection. All the stents demonstrated evidence of biofilm formation using both imaging modalities. The presence of various different sized organisms within a common exopolysaccharide matrix on CLSM suggested the existence of polymicrobial communities. The mean biomass of patient samples was 0.9385 μm³/μm² (range: 0.3901-1.9511 μm³/μm²). This is the first study to report the quantification of biomass on lacrimal stents. The presence of biofilms on lacrimal stents after DCR is a common finding but this need not necessarily translate to postoperative clinical infection.

  9. Surgical treatment of dacryocystitis caused by cystic dilatation of the nasolacrimal system in three dogs.

    PubMed

    van der Woerdt, A; Wilkie, D A; Gilger, B C; Smeak, D D; Kerpsack, S J

    1997-08-15

    A 4-year-old castrated male Golden Retriever was referred for evaluation of intermittent purulent discharge from the right eye of 4-months' duration. A radiolucent area in the maxillary bone was detected on examination of skull radiographs. Dacryocystorhinography revealed pooling of contrast material in the radiolucent area. A rhinotomy was performed, and a large opening between the cystic structure of the nasolacrimal system and the nasal cavity was created. Epiphora resolved after surgery and had not recurred by 9 months after surgery. Two other dogs had cystic structures of the nasolacrimal system and were treated surgically to allow drainage into the nasal cavity.

  10. Intubation methods by novice intubators in a manikin model.

    PubMed

    O'Carroll, Darragh C; Barnes, Robert L; Aratani, Ashley K; Lee, Dane C; Lau, Christopher A; Morton, Paul N; Yamamoto, Loren G; Berg, Benjamin W

    2013-10-01

    Tracheal Intubation is an important yet difficult skill to learn with many possible methods and techniques. Direct laryngoscopy is the standard method of tracheal intubation, but several instruments have been shown to be less difficult and have better performance characteristics than the traditional direct method. We compared 4 different intubation methods performed by novice intubators on manikins: conventional direct laryngoscopy, video laryngoscopy, Airtraq® laryngoscopy, and fiberoptic laryngoscopy. In addition, we attempted to find a correlation between playing videogames and intubation times in novice intubators. Video laryngoscopy had the best results for both our normal and difficult airway (cervical spine immobilization) manikin scenarios. When video was compared to direct in the normal airway scenario, it had a significantly higher success rate (100% vs 83% P=.02) and shorter intubation times (29.1 ± 27.4 sec vs 45.9 ± 39.5 sec, P=.03). In the difficult airway scenario video laryngoscopy maintained a significantly higher success rate (91% vs 71% P=0.04) and likelihood of success (3.2 ± 1.0 95%CI [2.9-3.5] vs 2.4 ± 0.9 95%CI [2.1-2.7]) when compared to direct laryngoscopy. Participants also reported significantly higher rates of self-confidence (3.5 ± 0.6 95%CI [3.3-3.7]) and ease of use (1.5 ± 0.7 95%CI [1.3-1.8]) with video laryngoscopy compared to all other methods. We found no correlation between videogame playing and intubation methods.

  11. Intubation Methods by Novice Intubators in a Manikin Model

    PubMed Central

    O'Carroll, Darragh C; Aratani, Ashley K; Lee, Dane C; Lau, Christopher A; Morton, Paul N; Yamamoto, Loren G; Berg, Benjamin W

    2013-01-01

    Tracheal Intubation is an important yet difficult skill to learn with many possible methods and techniques. Direct laryngoscopy is the standard method of tracheal intubation, but several instruments have been shown to be less difficult and have better performance characteristics than the traditional direct method. We compared 4 different intubation methods performed by novice intubators on manikins: conventional direct laryngoscopy, video laryngoscopy, Airtraq® laryngoscopy, and fiberoptic laryngoscopy. In addition, we attempted to find a correlation between playing videogames and intubation times in novice intubators. Video laryngoscopy had the best results for both our normal and difficult airway (cervical spine immobilization) manikin scenarios. When video was compared to direct in the normal airway scenario, it had a significantly higher success rate (100% vs 83% P=.02) and shorter intubation times (29.1±27.4 sec vs 45.9±39.5 sec, P=.03). In the difficult airway scenario video laryngoscopy maintained a significantly higher success rate (91% vs 71% P=0.04) and likelihood of success (3.2±1.0 95%CI [2.9–3.5] vs 2.4±0.9 95%CI [2.1–2.7]) when compared to direct laryngoscopy. Participants also reported significantly higher rates of self-confidence (3.5±0.6 95%CI [3.3–3.7]) and ease of use (1.5±0.7 95%CI [1.3–1.8]) with video laryngoscopy compared to all other methods. We found no correlation between videogame playing and intubation methods. PMID:24167768

  12. The Intubating Laryngeal Mask Airway Facilitates Tracheal Intubation in the Lateral Position

    PubMed Central

    Komatsu, Ryu; Nagata, Osamu; Sessler, Daniel I.; Ozaki, Makoto

    2005-01-01

    Although the difficulty of tracheal intubation in the lateral position has not been systematically evaluated, airway loss during surgery in a laterally positioned patient may have hazardous consequences. We explored whether the intubating laryngeal mask airway (ILMA) facilitates tracheal intubation in patients with normal airway anatomy, i.e., Mallampati grade ≤ 3 and thyromental distance ≥ 5 cm, positioned in the lateral position. And we evaluated whether this technique can be used as a rescue when the airway is lost mid-case in laterally positioned patients with respect to success rate and intubation time. Anesthesia was induced with propofol, fentanyl, and vecuronium in 50 patients undergoing spine surgery for lumbar disk herniation (Lateral) and 50 undergoing other surgical procedures (Supine). Patients having disk surgery (Lateral) were positioned on their right or left sides before induction of general anesthesia, and intubation was performed in that position. Patients in control group (Supine) were anesthetized in supine position, and intubation was performed in that position. Intubation was performed blindly via an ILMA in both groups. The time required for intubation and number and types of adjusting maneuvers employed were recorded. Data were compared by Mann-Whitney U, Fisher’s exact, chi-square, or unpaired t-tests, as appropriate. Data presented as mean (SD). Demographic and airway measures were similar in the two groups, except for mouth opening which was slightly wider in patients in the lateral position: 5.1 (0.9) vs. 4.6 (0.7) cm. The time required for intubation was similar in each group (≈25 s), as was intubation success (96%). We conclude that blind intubation via an ILMA offers a frequent success rate and a clinically acceptable intubation time (< one min) even in the lateral position. Summary Blind intubation via the intubating laryngeal mask airway (ILMA) offers a high success rate and a clinically acceptable intubation time even in

  13. Conventional tracheal tubes for intubation through the intubating laryngeal mask airway.

    PubMed

    Kundra, Pankaj; Sujata, N; Ravishankar, M

    2005-01-01

    The laryngeal mask airway (LMA)-Fastrach silicone wire-reinforced tracheal tube (FTST) was specially designed for tracheal intubation through the intubating LMA (ILMA). However, conventional tracheal tubes have been successfully used to accomplish tracheal intubation. We designed this study to evaluate the success rate of blind tracheal intubation through the ILMA by using the FTST, the Rusch polyvinyl chloride tube (PVCT), and the Rusch latex armored tube (LAT). One-hundred-fifty healthy adults of ASA physical status I and II who were undergoing elective surgery under general anesthesia were randomly allocated into three groups. FTST (n=50), prewarmed PVCT (n=50), and LAT (n=50) were used for tracheal intubation. Ease of tracheal intubation was assessed by the time taken, the number of attempts, and the number of maneuvers required for success. In addition, numbers of failed intubation attempts and times taken for ILMA removal were also recorded. After surgery, the incidence of trauma, sore throat, and hoarseness was noted. Significantly more frequent success in tracheal intubation was achieved with the PVCT and FTST (96%) compared with the LAT (82%) (P <0.05). Tracheal intubation on the first attempt was similar with the PVCT and FTST (86%) and was significantly more frequent than with the LAT (52%) (P <0.05). Esophageal placement was significantly more frequent with the LAT (29.7%) when compared with the PVCT and FTST (1.8% and 7.4%, respectively) (P <0.05). The authors conclude that a prewarmed PVCT can be used as successfully as the FTST for blind tracheal intubation through the ILMA, whereas the LAT is associated with more frequent failure and esophageal intubation.

  14. Nasolacrimal drainage system cyst in an adult.

    PubMed

    Yamasoba, T; Sugimura, H

    1996-01-01

    A cyst of the nasolacrimal drainage system (NLDS) is rare in an adult. We report a case in a 29-year-old man of a mucous retention cyst of the NLDS, which appeared 2 years after the patient developed dacryocystitis coincident with an aggravation of chronic sinusitis. The lesion was successfully managed by removing the bony wall of the NLDS at the interface with the ethmoid and nasal cavity, as well as the membranous closure of the ostium of the common canaliculus. We speculate that the cyst development might have been initiated by inflammatory change such as mucosal adhesion in the NLDS resulting from the spread of secondary infection from the sinonasal tract.

  15. Learning endotracheal intubation using a novel videolaryngoscope improves intubation skills of medical students.

    PubMed

    Herbstreit, Frank; Fassbender, Philipp; Haberl, Helge; Kehren, Clemens; Peters, Jürgen

    2011-09-01

    Teaching endotracheal intubation to medical students is a task provided by many academic anesthesia departments. We tested the hypothesis that teaching with a novel videolaryngoscope improves students' intubation skills. We prospectively assessed in medical students (2nd clinical year) intubation skills acquired by intubation attempts in adult anesthetized patients during a 60-hour clinical course using, in a randomized fashion, either a conventional Macintosh blade laryngoscope or a videolaryngoscope (C-MAC®). The latter permits direct laryngoscopy with a Macintosh blade and provides a color image on a video screen. Skills were measured before and after the course in a standardized fashion (METI Emergency Care Simulator) using a conventional laryngoscope. All 1-semester medical students (n = 93) were enrolled. The students' performance did not significantly differ between groups before the course. After the course, students trained with the videolaryngoscope had an intubation success rate on a manikin 19% higher (95% CI 1.1%-35.3%; P < 0.001) and intubated 11 seconds faster (95% CI 4-18) when compared with those trained using a conventional laryngoscope. The incidence of "difficult (manikin) laryngoscopy" was less frequent in the group trained with the videolaryngoscope (8% vs 34%; P = 0.005). Education using a video system mounted into a traditional Macintosh blade improves intubation skills in medical students.

  16. Wall-ablative laser-driven in-tube accelerator

    NASA Astrophysics Data System (ADS)

    Sasoh, Akihiro; Suzuki, Shingo; Matsuda, Atsushi

    2008-05-01

    The laser-driven in-tube accelerator in which the propellant is supplied from laser-ablated gas from the tube wall was developed. Proof-of concept demonstrations of vertical launch were successfully done. The device had a 25mm X 25mm square cross-section; two opposing walls were made of polyacetal and acted as the propellant, the other two acrylic window with guide grooves to the projectile. The upper end of the launch tube was connected to a vacuum chamber of an inner volume of 0.8 m2, in which the initial pressure was set to lower than 20 Pa. With plugging the bottom end of the launch tube, a momentum coupling coefficient exceeding 2.5 mN/W was obtained. Even with the bottom end connected to the same vacuum chamber through a different duct, the projectile was vertical launched successfully, obtaining 0.14 mN/W.

  17. Endoscopic modified medial maxillectomy for treatment of inverted papilloma originating from the maxillary sinus.

    PubMed

    Erbek, Selim S; Koycu, Alper; Buyuklu, Fuat

    2015-05-01

    Endoscopic approaches have become an alternative to external approaches in the treatment of sinonasal inverted papillomas (IPs) in recent years. The aim of this study was to analyze the outcomes of endoscopic modified medial maxillectomy preserving the nasolacrimal duct and the inferior turbinate in selected IP cases. Medical charts of patients diagnosed with IP originating from the maxillary sinus between July 2008 and August 2013 were reviewed. Eight patients who had undergone endoscopic modified medial maxillectomy were included in the study. Attachment of IP was located on the medial wall of the maxillary sinus in all cases. The nasolacrimal duct was preserved in all of the patients. The inferior turbinate was completely preserved in 5 patients, and the anterior part of the inferior turbinate was preserved in 3 patients. The mean follow-up period of the patients was 30.8 months (12-60  mo). None of the patients had recurrence or major complications. The postoperative complaints were minor hemorrhagic discharge and crusting for the first few weeks. Endoscopic modified medial maxillectomy preserving the nasolacrimal duct and the inferior turbinate provides good surgical and functional outcomes in selected IP cases.

  18. THE INCIDENCE OF SYMPTOMATIC ACQUIRED LACRIMAL OUTFLOW OBSTRUCTION AMONG RESIDENTS OF OLMSTED COUNTY, MINNESOTA, 1976–2000 (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    J., John; Woog

    2007-01-01

    Purpose To define the incidence, clinical characteristics, and outcomes following treatment of symptomatic acquired lacrimal outflow obstruction (SALOO) in Olmsted County, Minnesota, from 1976 to 2000, and to test the hypothesis that the incidence of this disorder increased over this interval. Methods In this retrospective, population-based study, the Rochester Epidemiology Project was used to identify patients above the age of 5 years with SALOO. Patient medical records were reviewed, and the incidence and localization of lacrimal obstruction were determined. Results Five-hundred eighty-seven patients with SALOO were identified, with an average annual incidence rate of 30.47 per 100,000. Nasolacrimal duct obstruction was most common, with an incidence of 20.24 per 100,000. The increase in incidence from 1976–1979 to 1996–2000 was statistically significant (P=.01). Among 397 patients with nasolacrimal duct obstruction, 107 (27%) were male and 290 (73%) female, with a mean age of 59.5 ± 22 years. SALOO and nasolacrimal duct obstruction incidence increased with age. Glaucoma, dry eye, cataract, diabetes mellitus, systemic malignancy, cigarette smoking, and hypertension were noted in 5.5%, 8.7%, 37.5%, 10.9%, 18.5%, 26.4%, and 41.1% of patients, respectively. One hundred eleven patients underwent dacryocystorhinostomy, with a success rate of 94.1%. Conclusions SALOO incidence increased during the study interval, although a possible plateau effect was noted during the last 5 years of the study period. The majority of patients were female above the age of 66 years. The latter finding, in conjunction with US demographic trends, suggests that the frequency of SALOO may continue to increase in the future. External dacryocystorhinostomy appeared to be effective in the management of nasolacrimal duct obstruction. PMID:18427633

  19. The Intubating Laryngeal Mask Airway Allows Tracheal Intubation When the Cervical Spine Is Immobilized by a Rigid Collar

    PubMed Central

    Komatsu, Ryu; Nagata, Osamu; Kamata, Kotoe; Yamagata, Katsuyuki; Sessler, Daniel I.; Ozaki, Makoto

    2005-01-01

    Summary An intubating laryngeal mask airway (ILMA) facilitates tracheal intubation with the neck in neutral position, which is similar to the neck position maintained by a rigid cervical collar. However, a cervical collar virtually obliterates neck movement, even the small movements that normally facilitate airway insertion. We therefore tested the hypothesis that the ILMA facilitates tracheal intubation even in patients wearing a rigid cervical collar. In 50 cervical spine surgery patients with a rigid Philadelphia collar in place and 50 general surgery patients under general anaesthesia, we performed blind tracheal intubation via an ILMA. The time required for intubation, intubation success rate, and numbers and type of adjusting manoeuvres employed were recorded. Inter-incisor distance was significantly smaller (4.1 [0.8] cm vs. 4.6 [0.7] cm, mean [SD], P<0.01) and Mallampati scores were significantly greater (P<0.001) in the collared patients. ILMA insertion took longer (30 [25] vs. 22 [6] seconds), more patients required 2 insertion attempts (15 vs. 3; P<0.005), and ventilation adequacy with ILMA was worse (P<0.05) in collared patients. However, there were no significant differences between the collared and control patients in terms of total time required for intubation (60 [41] vs. 50 [30] seconds), number of intubation attempts, overall intubation success rate (96 vs. 98%), or the incidence of intubation complications. Blind intubation through an ILMA is thus a reasonable strategy for controlling the airway in patients who are immobilized with a rigid cervical collar, especially when urgency precludes a fiberoptic approach. PMID:15321932

  20. Inaccuracy of diagnosis in a cohort of patients on the waiting list for dacryocystorhinostomy when the diagnosis was made by only syringing the lacrimal system.

    PubMed

    Beigi, B; Uddin, J M; McMullan, T F W; Linardos, E

    2007-01-01

    Accurate identification of the factors contributing to epiphora is essential in directing appropriate management and treatment strategies. The authors applied a methodical strategy of assessment for epiphora to patients who were already on the waiting list for dacryocystorhinostomy (DCR). The findings were compared to the original findings. Forty-four eyes of 35 patients listed for DCR were re-examined. All canaliculi were examined using four tests: dye disappearance, Jones 1 (dye retrieval), probing using Bowman probes, and syringing of the nasolacrimal duct (NLD) under local anesthesia. Some patients were examined using an endocanalicular mini-endoscope. Patients with NLD obstruction underwent DCR and those with canalicular and NLD stenosis underwent intubation of the lacrimal system-canaliculus, lacrimal sac, and nasolacrimal duct-using silicone stents. The authors refer to this as canaliculodacryocystoplasty (CDCP). The patients were assessed for symptoms of epiphora at 12 months. Forty-four eyes had been listed for DCR. They had been originally diagnosed, by means of lacrimal syringing, as NLD obstruction (24 eyes) or stenosis (12 eyes), and functional blocks (8 eyes). Four out of the original 44 planned DCR surgeries were performed after re-evaluation. After re-examination, 28 lacrimal systems were found to have canalicular stenosis, 4 NLD stenosis, 4 NLD obstruction, 4 punctal phimosis, 3 ocular surface disease, and 1 patient was asymptomatic. Twenty-eight lacrimal systems underwent CDCP, 4 underwent DCR, 4 had punctoplasty, and 4 had probing alone. Three had treatment for ocular surface disease and one patient required no treatment. After a follow-up of 12 months, 41 (93%) systems had improvement or were free of their Syringing of the lacrimal apparatus may result in a high false positive diagnosis of NLD obstruction. Canalicular pathology is not uncommon in this cohort of patients and may be underdiagnosed.

  1. Acute dacryocystitis associated with epstein-barr virus infection.

    PubMed

    Ghauri, Abdul-Jabbar; Keane, Pearse A; Scotcher, Stephen M; Clarke, Jayne L; Madge, Simon N

    2011-10-01

    Acute dacryocystitis is a rare complication of infectious mononucleosis with only three previous reports in the English literature. We present two further children with acute dacryocystitis and clinical and laboratory features of Epstein-Barr Virus related infectious mononucleosis. Both were treated with systemic antibiotics and one child additionally required surgical drainage of a lacrimal sac abscess. Both children made a complete recovery without any lacrimal symptoms. Acute dacryocystitis is uncommon in children without a history of congenital nasolacrimal duct obstruction, and an underlying systemic condition such as infectious mononucleosis should be suspected. In such patients, dacryocystitis can be expected to resolve without symptoms of nasolacrimal duct obstruction and dacryocystorhinostomy is seldom required.

  2. Modified transnasal endoscopic medial maxillectomy through prelacrimal duct approach.

    PubMed

    Suzuki, Motohiko; Nakamura, Yoshihisa; Yokota, Makoto; Ozaki, Shinya; Murakami, Shingo

    2017-10-01

    We previously reported a modified endoscopic medial maxillectomy (modified transnasal endoscopic medial maxillectomy through prelacrimal duct approach [MTEMMPDA]) to resect inverted papilloma (IP), for which the inferior turbinate (IT) and nasolacrimal duct (ND) can be preserved. MTEMMPDA is a safe and effective method to obtain wide, straight access to the maxillary sinus (MS). However, there are few reported cases of patients who underwent MTEMMPDA, and even fewer of patients who underwent partial osteotomy of the apertura piriformis and the anterior wall of the MS. In this study, we analyzed the outcomes of 51 patients who underwent MTEMMPDA. Retrospective review. All patients who underwent MTEMMPDA at our hospital between January 2004 and December 2015 were included in this study. Fifty-one patients with sinonasal IP in the MS underwent MTEMMPDA. Recurrence was seen in the MS of one patient (follow-up of 2-138 months). The IT remained unchanged in all 51 patients without atrophy. We have not observed epiphora, eye discharge, dry nose, or persistent crusting after this surgery. Although seven patients had numbness around the upper lip after surgery, this had disappeared by 1 year after surgery. Additional partial osteotomy of the apertura piriformis and the anterior wall of the MS were done in eight patients. Deformation of the external nose was not seen. This approach appears to be a safe and effective method to resect IP in the MS, even if there is additional partial osteotomy of the apertura piriformis and the anterior wall of the MS. 4. Laryngoscope, 127:2205-2209, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  3. The intubating laryngeal mask. II: A preliminary clinical report of a new means of intubating the trachea.

    PubMed

    Brain, A I; Verghese, C; Addy, E V; Kapila, A; Brimacombe, J

    1997-12-01

    We have assessed the efficacy of a new laryngeal mask prototype, the intubating laryngeal mask airway (ILMA), as a ventilatory device and blind intubation guide. The ILMA consists of an anatomically curved, short, wide bore, stainless steel tube sheathed in silicone which is bonded to a laryngeal mask and a guiding handle. It has a single moveable aperture bar, a guiding ramp and can accommodate an 8 mm tracheal tube (TT). After induction of anaesthesia with propofol 2.5 mg kg-1 and fentanyl 2.5 micrograms kg-1, the device was inserted successfully at the first attempt in all 150 (100%) patients and adequate ventilation achieved in all, with minor adjustments required in four patients. Placement did not require movement of the head and neck or insertion of the fingers in the patient's mouth. Blind tracheal intubation using a straight silicone cuffed TT was attempted after administration of atracurium 0.5 mg kg-1. If resistance was felt during intubation, a sequence of adjusting manoeuvres was used based on the depth at which resistance occurred. Tracheal intubation was possible in 149 of 150 (99.3%) patients. In 75 (50%) patients no resistance was encountered and the trachea was intubated at the first attempt, 28 (19%) patients required one adjusting manoeuvre and 46 (31%) patients required 2-4 adjusting manoeuvres before intubation was successful. There were 13 patients with potential or known airway problems. The lungs of all of these patients were ventilated easily and the trachea intubated using the ILMA. In 10 of 13 (77%) of these patients, no resistance was encountered and the trachea was intubated at the first attempt; three of 13 (23%) patients required one adjusting manoeuvre. Tracheal intubation required significantly fewer adjusting manoeuvres in patients with a predicted or known difficult airway (P < 0.05). We conclude that the ILMA appeared on initial assessment to be an effective ventilatory device and intubation guide for routine and difficult

  4. A Randomized Crossover Study Comparing Cervical Spine Motion During Intubation Between Two Lightwand Intubation Techniques in Patients With Simulated Cervical Immobilization: Laryngoscope-Assisted Versus Conventional Lightwand Intubation.

    PubMed

    Kim, Tae Kyong; Son, Je-Do; Seo, Hyungseok; Lee, Yun-Seok; Bae, Jinyoung; Park, Hee-Pyoung

    2017-08-01

    In patients with cervical immobilization, jaw thrust can cause cervical spine movement. Concurrent use of a laryngoscope may facilitate lightwand intubation, allowing midline placement and free movement of the lightwand in the oral cavity without jaw thrust. We compared the effects of laryngoscope-assisted lightwand intubation (LALI) versus conventional lightwand intubation (CLI) on cervical spine motion during intubation in patients with simulated cervical immobilization. In this randomized crossover study, the cervical spine angle was measured before and during intubation at the occiput-C1, C1-C2, and C2-C5 segments in 20 patients with simulated cervical immobilization who underwent intubation using both the LALI and CLI techniques. Cervical spine motion was defined as the change from baseline in angle measured at each cervical segment during intubation. Cervical spine motion at the occiput-C1 segment was 5.6° (4.3) and 9.3° (4.5) when we used the LALI and CLI techniques, respectively (mean difference [98.33% CI]; -3.8° [-7.2 to -0.3]; P = .007). At other cervical segments, it was not significantly different between the 2 techniques (-0.1° [-2.6 to 2.5]; P = .911 in the C1-C2 segment and -0.2° [-2.8 to 2.5]; P = .795 in the C2-C5 segment). The LALI technique produces less upper cervical spine motion during intubation than the CLI technique in patients with simulated cervical immobilization.

  5. Intubation Biomechanics: Laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes

    PubMed Central

    Hindman, Bradley J.; Santoni, Brandon G.; Puttlitz, Christian M.; From, Robert P.; Todd, Michael M.

    2014-01-01

    Introduction Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two laryngoscopes hypothesized to differ in force. Methods Fourteen adults undergoing elective surgery were intubated twice (Macintosh, Airtraq). During each intubation, laryngoscope force, cervical spine motion, and glottic view were recorded. Force and motion were referenced to a pre-intubation baseline (stage 1) and were characterized at three stages: stage 2 (laryngoscope introduction); stage 3 (best glottic view); stage 4 (endotracheal tube in trachea). Results Maximal force and motion occurred at stage 3, and differed between the Macintosh and Airtraq: 1) Force: 48.8±15.8 vs. 10.4±2.8 N, respectively; P=0.0001; 2) occiput-C5 extension: 29.5±8.5 vs. 19.1±8.7 degrees, respectively; P=0.0023. Between stages -2 and -3, the motion/force ratio differed between Macintosh and Airtraq: 0.5±0.2 vs. 2.0±1.4 degrees/N, respectively; P=0.0006. Discussion The relationship between laryngoscope force and cervical spine motion is: 1) non-linear and 2) differs between laryngoscopes. Differences between laryngoscopes in motion/force relationships are likely due to: 1) laryngoscope-specific cervical extension needed for intubation, 2) laryngoscope-specific airway displacement/deformation needed for intubation, and 3) cervical spine and airway tissue viscoelastic properties. Cervical spine motion during endotracheal intubation is not directly proportional to force. Low force laryngoscopes cannot be assumed to result in proportionally low cervical spine motion. PMID:24739996

  6. Intubation biomechanics: laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes.

    PubMed

    Hindman, Bradley J; Santoni, Brandon G; Puttlitz, Christian M; From, Robert P; Todd, Michael M

    2014-08-01

    Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two laryngoscopes hypothesized to differ in force. Fourteen adults undergoing elective surgery were intubated twice (Macintosh, Airtraq). During each intubation, laryngoscope force, cervical spine motion, and glottic view were recorded. Force and motion were referenced to a preintubation baseline (stage 1) and were characterized at three stages: stage 2 (laryngoscope introduction); stage 3 (best glottic view); and stage 4 (endotracheal tube in trachea). Maximal force and motion occurred at stage 3 and differed between the Macintosh and Airtraq: (1) force: 48.8 ± 15.8 versus 10.4 ± 2.8 N, respectively, P = 0.0001; (2) occiput-C5 extension: 29.5 ± 8.5 versus 19.1 ± 8.7 degrees, respectively, P = 0.0023. Between stages 2 and 3, the motion/force ratio differed between Macintosh and Airtraq: 0.5 ± 0.2 versus 2.0 ± 1.4 degrees/N, respectively; P = 0.0006. The relationship between laryngoscope force and cervical spine motion is: (1) nonlinear and (2) differs between laryngoscopes. Differences between laryngoscopes in motion/force relationships are likely due to: (1) laryngoscope-specific cervical extension needed for intubation, (2) laryngoscope-specific airway displacement/deformation needed for intubation, and (3) cervical spine and airway tissue viscoelastic properties. Cervical spine motion during endotracheal intubation is not directly proportional to force. Low-force laryngoscopes cannot be assumed to result in proportionally low cervical spine motion.

  7. Biofilms and Physical Deposits on Nasolacrimal Silastic Stents Following Dacryocystorhinostomy: Is There a Difference Between Ocular and Nasal Segments?

    PubMed

    Ali, Mohammad Javed; Baig, Farhana; Lakshman, Mekala; Naik, Milind N

    2015-01-01

    The aims of this study were to examine the presence of biofilms and physical deposits on ocular and nasal segments of silastic nasolacrimal duct stents inserted after dacryocystorhinostomy and to document any differences. A prospective interventional study was performed on a series of patients undergoing dacryocystorhinostomy with Crawford stent insertion. All the patient samples were retrieved 4 weeks after an endoscopic dacryocystorhinostomy. None of the patients had any evidence of postoperative infection. The ocular and nasal segments were separated during retrieval. After removal, the stent segments were subjected to biofilm and physical deposit analysis using standard protocols of scanning electron microscopy. These stent segments were compared against sterile stents which acted as controls. A total of 11 stents were studied. Nine were consecutive patient samples and 2 were sterile stents. The ocular and nasal segments of all the stents demonstrated evidence of biofilm formation and physical deposits. However, the deposits and biofilms were thicker and extensive in the ocular segment, although more focal in nature. In contrast, the nasal segments showed thinner biofilms and sparser deposits but were more diffuse in nature. The presence of different-sized organisms within the exopolysaccharide matrix and in between the deposits suggests the existence of polymicrobial communities. This is the first study to report the differences between ocular and nasal segments of lacrimal stents. These differences could propel further studies on stent biomechanics and their interactions with ocular and nasal tissues, following a dacryocystorhinostomy.

  8. Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in neonates.

    PubMed

    Lingappan, Krithika; Arnold, Jennifer L; Fernandes, Caraciolo J; Pammi, Mohan

    2018-06-04

    Establishment of a secure airway is a critical part of neonatal resuscitation in the delivery room and the neonatal unit. Videolaryngoscopy has the potential to facilitate successful endotracheal intubation and decrease adverse consequences of delay in airway stabilization. Videolaryngoscopy may enhance visualization of the glottis and intubation success in neonates. To determine the efficacy and safety of videolaryngoscopy compared to direct laryngoscopy in decreasing the time and attempts required for endotracheal intubation and increasing the success rate at first intubation in neonates. We used the search strategy of Cochrane Neonatal. In May 2017, we searched for randomized controlled trials (RCT) evaluating videolaryngoscopy for neonatal endotracheal intubation in Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, CINAHL, abstracts of the Pediatric Academic Societies, websites for registered trials at www.clinicaltrials.gov and www.controlled-trials.com, and reference lists of relevant studies. RCTs or quasi-RCTs in neonates evaluating videolaryngoscopy for endotracheal intubation compared with direct laryngoscopy. Review authors performed data collection and analysis as recommended by Cochrane Neonatal. Two review authors independently assessed studies identified by the search strategy for inclusion.We used the GRADE approach to assess the quality of evidence. The search yielded 7057 references of which we identified three RCTs for inclusion, four ongoing trials and one study awaiting classification. All three included RCTs compared videolaryngoscopy with direct laryngoscopy during intubation attempts by trainees.Time to intubation was similar between videolaryngoscopy and direct laryngoscopy (mean difference (MD) -0.62, 95% confidence interval (CI) -6.50 to 5.26; 2 studies; 311 intubations) (very low quality evidence). Videolaryngoscopy did not decrease the number of intubation attempts (MD -0.05, 95% CI -0.18 to 0.07; 2 studies; 427

  9. Intubation Biomechanics: Laryngoscope Force and Cervical Spine Motion during Intubation in Cadavers—Cadavers vs. Patients, the Effect of Repeated Intubations, and the Effect of Type II Odontoid Fracture on C1-C2 Motion

    PubMed Central

    Hindman, Bradley J.; From, Robert P.; Fontes, Ricardo B.; Traynelis, Vincent C.; Todd, Michael M.; Zimmerman, M. Bridget; Puttlitz, Christian M.; Santoni, Brandon G.

    2015-01-01

    Introduction The aims of this study were to characterize: 1) cadaver intubation biomechanics, including the effect of repeated intubations; and 2) the relationship between intubation force and the motion of an injured cervical segment. Methods Fourteen cadavers were serially intubated using force-sensing Macintosh and Airtraq laryngoscopes in random order, with simultaneous cervical spine motion recorded with lateral fluoroscopy. Motion of the C1-C2 segment was measured in the intact and injured state (Type II odontoid fracture). Injured C1-C2 motion was proportionately corrected for changes in intubation forces that occurred with repeated intubations. Results Cadaver intubation biomechanics were comparable to those of patients in all parameters other than C2-C5 extension. In cadavers, intubation force (Set 2/Set1 force ratio = 0.61 [95% CI: 0.46, 0.81]; P=0.002) and Oc-C5 extension (Set 2 –Set 1 difference = −6.1 degrees [95% CI: −11.4, −0.9]; P=0.025) decreased with repeated intubations. In cadavers, C1-C2 extension did not differ: 1) between intact and injured states; or 2) in the injured state, between laryngoscopes (with and without force correction). With force correction, in the injured state, C1-C2 subluxation was greater with the Airtraq (mean difference 2.8 mm [95% CI: 0.7, 4.9 mm]; P=0.004). Discussion With limitations, cadavers may be clinically relevant models of intubation biomechanics and cervical spine motion. In the setting of a Type II odontoid fracture, C1-C2 motion during intubation with either the Macintosh or Airtraq does not appear to greatly exceed physiologic values or to have a high likelihood of hyperextension or direct cord compression. PMID:26288267

  10. Incidence and predictors of difficult nasotracheal intubation with airway scope.

    PubMed

    Ono, Koyu; Goto, Tomoko; Nakai, Daishi; Ueki, Shuhei; Takenaka, Seiichiro; Moriya, Tomomi

    2014-10-01

    The airway scope (AWS) improves views of the larynx during orotracheal intubation. However, the role of the AWS in routine nasotracheal intubation has not been studied adequately. One hundred and three patients undergoing dental and maxillofacial surgery that required general anesthesia and nasotracheal intubation were enrolled. The study was approved by our Institution Review Board, and written informed consent was obtained from all patients. We evaluated the success rate of AWS intubation and the incidence of difficult nasotracheal intubation using a modified intubation difficulty scale (IDS) to examine preoperative characteristics and intubation profiles. Categories were difficult intubation (IDS ≥5), mildly difficult (IDS = 1-4), and intubation without difficulty (IDS = 0). We also assessed the incidence of the use of Magill forceps or cuff inflation (the cuff of endotracheal tube is inflated with 10-15 ml air) to guide the endotracheal tube into the glottis. AWS nasotracheal intubation was 100% successful. The cuff inflation technique was used in 37 patients. Neither Magill forceps nor other devices were needed for any patient during AWS use. The incidence of difficult nasotracheal intubation was 10% (n = 10). Of the patients, 61% (n = 63) had mildly difficult intubation and 29% (n = 30) had no difficulty. Patients with difficult intubation were more likely to be male and to have a larger tongue and a higher Cormack grade than in the other two groups. Complications, involving minor soft tissue injury, were observed in only 1 patient (1%). The AWS achieves a high success rate for nasotracheal intubation with cuff inflation in patients undergoing dental and maxillofacial surgery.

  11. A survey of Canadian anesthesiologists' preferences in difficult intubation and "cannot intubate, cannot ventilate" situations.

    PubMed

    Wong, David T; Mehta, Arpan; Tam, Amanda D; Yau, Brian; Wong, Jean

    2014-08-01

    The purpose of this survey was to determine the equipment that anesthesiologists prefer in difficult tracheal intubation and "cannot intubate, cannot ventilate" (CICV) situations. A questionnaire was e-mailed to members of the Canadian Anesthesiologists' Society to ascertain their preferences, experience, and comfort level with regard to their use of airway equipment in difficult intubation and CICV situations in adult patients. A Chi square test was used to analyse the data. All reported P values are two-sided. Nine hundred ninety-seven of 2,532 questionnaires (39%) were returned. In an unanticipated difficult direct laryngoscopic intubation situation, 893 of 997 (90%) respondents chose a video laryngoscope as the first-choice rescue technique, while 41 (4%) and 21 (2%) of respondents chose a flexible bronchoscope and an intubating laryngeal mask airway device, respectively. The majority of anesthesiologists had experience and were comfortable with using a flexible bronchoscope or a video laryngoscope. Regarding CICV, 294 of 955 (31%) respondents stated that they had never encountered it. Wire-guided cricothyroidotomy was chosen as the first-choice surgical airway by 375 of 955 (39%) respondents, while intravenous catheter cricothyroidotomy and "defer to tracheostomy by surgeon" were selected by 266 (28%) and 215 (23%) respondents, respectively. Seven hundred eighty-five of 997 (78%) respondents were familiar with the exact steps of the American Society of Anesthesiologists' difficult airway algorithm, while 448 (47%) had attended an airway workshop within the past five years. In a difficult intubation situation, the most frequently selected first-choice airway device was a video laryngoscope, followed by a flexible bronchoscope. In a CICV situation, the most frequently selected first-choice surgical airway technique was a wire-guided cricothyroidotomy, followed by an intravenous catheter cricothyroidotomy.

  12. Ease of intubation: A randomized, double-blind study to compare two doses of rocuronium bromide for endotracheal intubation.

    PubMed

    Shukla, Aparna; Misra, Shilpi

    2016-01-01

    Clinical need for a nondepolarizing agent with a rapid onset time and a brief duration of action has led to the development of rocuronium bromide. The aim of this study was to evaluate optimal dose of rocuronium bromide for intubation and to compare the onset time, duration of action, intubating conditions, and hemodynamic effects of two doses of rocuronium bromide. A prospective, randomized, double-blind study. All the patients were divided in a randomized, double-blind fashion into two groups of twenty patients each. Group I patients received rocuronium bromide 0.6 mg/kg intravenously and intubated at 60 s, Group II patients received rocuronium bromide 0.9 mg/kg and intubated at 60 s. The neuromuscular block was assessed using single twitch stimulation of 0.1 Hz at adductor pollicis muscle of hand at every 10 s. The results were compiled and analyzed statistically using Chi-square test for qualitative data and Student's t -test for quantitative data. Time of onset was significantly shorter ( P < 0.01) and duration of action was prolonged ( P < 0.001) for Group II as compared to Group I. The intubating conditions were (excellent + good) in 100% patients of Group II and (excellent + good) in 80% of Group I. There was no significant change in pulse rate and mean arterial pressure from the baseline value after the administration of muscle relaxants in either of the two groups. Rocuronium bromide 0.9 mg/kg is a safer alternative to rocuronium bromide 0.6 mg/kg for endotracheal intubation with shorter time of onset and better intubating conditions.

  13. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study.

    PubMed

    Michalek, P; Donaldson, W; Graham, C; Hinds, J D

    2010-01-01

    Insertion of a supraglottic airway and tracheal intubation through it may be indicated in resuscitation scenarios where conventional laryngoscopy fails. Various supraglottic devices have been used as conduits for tracheal intubation, including the intubating laryngeal mask airway (ILMA), the Ctrach laryngeal mask and the I-gel supraglottic airway. A prospective study with 25 participants evaluated the success rate of blind intubation (using a gum-elastic bougie, an Aintree intubating catheter (AIC) and designated tracheal tube) and fibrescope-guided tracheal intubation (through the intubating laryngeal mask airway and the I-gel supraglottic airway) on three different airway manikins. Twenty-five anaesthetists performed three intubations with each method on each of three manikins. The success rate of the fibrescope-guided technique was significantly higher than blind attempts (P<0.0001) with both devices. For fibreoptic techniques, there was no difference found between the ILMA and I-gel (P>0.05). All blind techniques were significantly more successful in the ILMA group compared to the I-gel (P<0.0001 for bougie, Aintree catheter and tracheal tube, respectively). The results of this study show that, in manikins, fibreoptic intubation through both ILMA and I-gel is a highly successful technique. Blind intubation through the I-gel showed a low success rate and should not be attempted. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  14. Point-of-care sonographic detection of left endobronchial main stem intubation and obstruction versus endotracheal intubation.

    PubMed

    Blaivas, Michael; Tsung, James W

    2008-05-01

    Determining the correct position of endotracheal tubes in critically ill patients may be complicated by external factors such as noise, body habitus, and the need for ongoing resuscitation. Multiple detection techniques have been developed to determine the correct endotracheal tube position, recently including the use of sonography to evaluate lung expansion and diaphragmatic excursion. These techniques have also been applied to diagnosis of right endobronchial main stem intubation, which may be confused with a unilateral pneumothorax in some cases. We describe the sonographic findings in a case series of endobronchial main stem intubations and obstruction, highlighting the utility of this sonographic application. Previous literature and future applications are discussed. Sonographic detection of the sliding lung sign, the lung pulse, and diaphragmatic excursion can accurately detect main stem bronchial intubation as well as bronchial obstruction. Clinical use of lung sonography may decrease the need for chest radiography and may allow more rapid diagnosis of main stem intubation and bronchial obstruction.

  15. Endotracheal Intubation and In-Hospital Mortality after Intracerebral Hemorrhage.

    PubMed

    Lioutas, Vasileios-Arsenios; Marchina, Sarah; Caplan, Louis R; Selim, Magdy; Tarsia, Joseph; Catanese, Luciana; Edlow, Jonathan; Kumar, Sandeep

    2018-06-13

    Many patients with acute intracerebral hemorrhages (ICHs) undergo endotracheal intubation with subsequent mechanical ventilation (MV) for "airway protection" with the intent to prevent aspiration, pneumonias, and its related mortality. Conversely, these procedures may independently promote pneumonia, laryngeal trauma, dysphagia, and adversely affect patient outcomes. The net benefit of intubation and MV in this patient cohort has not been systematically investigated. We conducted a large single-center observational cohort study to examine the independent association between endotracheal intubation and MV, hospital-acquired pneumonia (HAP), and in-hospital mortality (HM) in patients with ICH. All consecutive patients admitted with a primary diagnosis of a spontaneous ICH to a tertiary care hospital in Boston, Massachusetts, from June 2000 through January 2014, who were ≥18 years of age and hospitalized for ≥2 days were eligible for inclusion. Patients with pneumonia on admission, or those having brain or lung neoplasms were excluded. Our exposure of interest was endotracheal intubation and MV during hospitalization; our primary outcomes were incidence of HAP and HM, ascertained using International Classification of Diseases-9 and administrative discharge disposition codes, respectively, in patients who underwent endotracheal intubation and MV versus those who did not. Multivariable logistic regression was used to control for confounders. Of the 2,386 hospital admissions screened, 1,384 patients fulfilled study criteria and were included in the final analysis. A total of 507 (36.6%) patients were intubated. Overall 133 (26.23%) patients in the intubated group developed HAP versus 41 (4.67%) patients in the non-intubated group (p < 0.0001); 195 (38.5%) intubated patients died during hospitalization compared to 48 (5.5%) non-intubated patients (p < 0.0001). After confounder adjustments, OR for HAP and HM, were 4.23 (95% CI 2.48-7.22; p < 0.0001) and 4.32 (95% CI 2

  16. Ducted turbine theory with right angled ducts

    NASA Astrophysics Data System (ADS)

    McLaren-Gow, S.; Jamieson, P.; Graham, J. M. R.

    2014-06-01

    This paper describes the use of an inviscid approach to model a ducted turbine - also known as a diffuser augmented turbine - and a comparison of results with a particular one-dimensional theory. The aim of the investigation was to gain a better understanding of the relationship between a real duct and the ideal diffuser, which is a concept that is developed in the theory. A range of right angled ducts, which have a rim for a 90° exit angle, were modelled. As a result, the performance of right angled ducts has been characterised in inviscid flow. It was concluded that right angled ducts cannot match the performance of their associated ideal diffuser and that the optimum rotor loading for these turbines varies with the duct dimensions.

  17. Comparison between the Trachway video intubating stylet and Macintosh laryngoscope in four simulated difficult tracheal intubations: A manikin study

    PubMed Central

    Ong, Jimmy; Lee, Chia-Ling; Huang, Shen-Jer; Shyr, Ming-Hwang

    2016-01-01

    Objectives: It remains to be determined whether the TVI-4000 Trachway video intubating (TVI) stylet (Markstein Sichtec Medical Corp, Taichung, Taiwan), an airway device for novices, improves airway management practice by experienced anesthesiologists. The aim of this study was to evaluate the feasibility of using the TVI stylet in difficult tracheal intubation situations compared with that of using the Macintosh laryngoscope on an airway manikin. Materials and Methods: Ten anesthesiologists (with 3–21 years’ experience), including three senior residents, participated. We compared tracheal intubation in four airway scenarios: normal airway, tongue edema, cervical spine immobilization, and tongue edema combined with cervical spine immobilization. The time of tracheal intubation (TTI), success rate, and perceived difficulty of intubation for each scenario were compared and analyzed. Results: The TTI was significantly shorter in both the tongue edema and combined scenarios with the TVI stylet compared with the Macintosh laryngoscope (21.60 ± 1.45 seconds vs. 24.07 ± 1.58 seconds and 23.73 ± 2.05 seconds vs. 26.6 ± 2.77 seconds, respectively). Success rates for both devices were 100%. Concomitantly, participants rated using the TVI stylet in these two scenarios as being less difficult. Conclusion: The learning time for tracheal intubation using the TVI stylet in difficult airway scenarios was short. Use of the TVI stylet was easier and required a shorter TTI for tracheal intubation in the tongue edema and combined scenarios. PMID:28757736

  18. Tracheal intubation in the emergency department: a comparison of GlideScope® video laryngoscopy to direct laryngoscopy in 822 intubations.

    PubMed

    Sakles, John C; Mosier, Jarrod M; Chiu, Stephen; Keim, Samuel M

    2012-04-01

    Video laryngoscopy has, in recent years, become more available to emergency physicians. However, little research has been conducted to compare their success to conventional direct laryngoscopy. To compare the success rates of GlideScope(®) (Verathon Inc., Bothell, WA) videolaryngoscopy (GVL) with direct laryngoscopy (DL) for emergency department (ED) intubations. This was a 24-month retrospective observational study of all patients intubated in a single academic ED with a level I trauma center. Structured data forms were completed after each intubation and entered into a continuous quality improvement database. All patients intubated in the ED with either the GlideScope(®) standard, Cobalt, Ranger, or traditional Macintosh or Miller laryngoscopes were included. All patients intubated before arrival were excluded. Primary analysis evaluated overall and first-attempt success rates, operator experience level, performance characteristics of GVL, complications, and reasons for failure. There were 943 patients intubated during the study period; 120 were excluded due to alternative management strategies. DL was used in 583 (62%) patients, and GVL in 360 (38%). GVL had higher first-attempt success (75%, p = 0.03); DL had a higher success rate when more than one attempt was required (57%, p = 0.003). The devices had statistically equivalent overall success rates. GVL had fewer esophageal intubations (n = 1) than DL (n = 18); p = 0.005. The two techniques performed equivalently overall, however, GVL had a higher overall success rate, and lower number of esophageal complications. In the setting of ED intubations, GVL offers an excellent option to maximize first-attempt success for airway management. Published by Elsevier Inc.

  19. Tracheal intubation with rocuronium using a "modified timing principle".

    PubMed

    Kwon, Min A; Song, Jaegyok; Kim, Ju-Ri

    2013-03-01

    Rapid sequence induction (RSI) is indicated in various situations. Succinylcholine has been the muscle relaxant of choice for RSI, and rocuronium has become an alternative medicine for patients who cannot be administered succinylcholine for various reasons. Although rocuronium has the most rapid onset time among non-depolarizing muscle relaxants, the standard dose of rocuronium (0.6 mg/kg) takes 60 seconds to achieve appropriate muscle relaxation. We evaluated intubating conditions using the "modified timing principle" with rocuronium and succinylcholine. In this prospective controlled blinded study, all patients received 1.5 µg/kg fentanyl intravenously with preoxygenation for 2 minutes and were randomized to receive 0.6 mg/kg rocuronium followed by 1.5 mg/kg propofol or 1.5 mg/kg propofol and 1.5 mg/kg succinylcholine. The rocuronium group was intubated just after confirming loss of consciousness, and the succinylcholine group was intubated 1 minute after injecting succinylcholine. Intubation condition, timing of events, and complications were recorded. All patients were successfully intubated in both groups. Apnea time of the rocuronium group (38.5 seconds) was significantly shorter than that in the succinylcholine group (100.7 seconds). No significant differences were observed in loss of consciousness time or intubation time. The succinylcholine group tended to show better intubation conditions, but no significant difference was observed. None of the patients complained awareness of the intubation procedure or had respiratory difficulty during a postoperative interview. The modified RSI with rocuronium showed shorter intubation sequence, acceptable intubation conditions, and a similar level of complications compared to those of conventional RSI with succinylcholine.

  20. Endoscopic dacryocystorhinostomy with silicone, polypropylene, and T-tube stents; randomized controlled trial of efficacy and safety.

    PubMed

    Okuyucu, Semsettin; Gorur, Hatice; Oksuz, Huseyin; Akoglu, Ertap

    2015-01-01

    To compare the efficacy and safety of endoscopic dacryocystorhinostomy (En-DCR) with different stent materials for lacrimal sac intubation in primary nasolacrimal ductal obstructions. Randomized controlled study with three parallel groups. Level of evidence is 1b. A total of 91 patients (five bilateral) with primary nasolacrimal duct obstruction (NLDO) at a tertiary referral center scheduled for En-DCR were to allocated into three stent groups with a sealed envelope and were randomized into three treatments: silicone, Prolene (polypropylene), and otologic T-tube. Ophthalmology and otolaryngology clinics evaluated the patients preoperatively and postoperatively with endoscopes, lacrimal system syringing, and dacryocystography. The success of the stents was evaluated 12 months after surgery with symptom relief and ostial patency. Complications were also noted. The overall success rate of the En-DCR in the stent groups was 78.1% (75/96); specifically, 87.5% (28/32) with silicone, 84.4% (27/32) with Prolene, and 62.5% (20/32) with T-tube. The efficacy of the procedures with the T-tube was significantly lower than that of the Prolene and silicone (p = .031, χ(2) test). There were no significant differences between the silicone and Prolene (p = .718, χ(2) test). Prolene was found to be related with orbital complications. Spontaneous loss is a particular complication of otologic T-tube and highly portends to failure. The results of our study suggest that efficacy, defined as anatomic and functional success, is equally high for silicone and Prolene stents and lower for otologic T-tube in En-DCR.

  1. Alcohol-induced chronic pancreatitis in rats after temporary occlusion of biliopancreatic ducts with Ethibloc.

    PubMed

    Pap, A; Boros, L

    1989-01-01

    Chronic obstructive pancreatitis-like histological and biochemical alterations were provoked in male Wistar rats with Ethibloc occlusion of the common bile duct and the main pancreatic ducts. After the disappearance of the glue from the ducts, a gradual and almost total recovery was demonstrated during a 2-month observation period. About 12 g/kg of alcohol (20% vol/vol) given daily by gastric intubation and ad libitum intake inhibited the recovery of pancreatic weight and enzyme contents in the occluded rats, and within a 2-month period chronic calcifying-type pancreatitis became evident with some signs of remaining obstructive pancreatitis-like lesions. Cessation of alcohol administration after 2 months resulted in a recovery of pancreatic weight and enzyme contents, although morphological regeneration was less pronounced and calcification remained visible in some rats. A 50% raw soy flour diet provoked some further changes in the proportion of enzymes without any supplementary increases of pancreatic weight and protein content. This animal model of chronic pancreatitis demonstrates that chronic obstructive and calcifying pancreatitis can appear together and earlier if the etiological factors act in combination. Suppression of pancreatic regeneration by alcohol seems to be necessary to maintain chronic pancreatitis-like lesions and to develop calcification.

  2. Encountering unexpected difficult airway: relationship with the intubation difficulty scale

    PubMed Central

    Koh, Wonuk; Kim, Hajung; Kim, Kyongsun; Ro, Young-Jin

    2016-01-01

    Background An unexpected difficult intubation can be very challenging and if it is not managed properly, it may expose the encountered patient to significant risks. The intubation difficulty scale (IDS) has been used as a validated method to evaluate a global degree of intubation difficulty. The aims of this study were to evaluate the prevalence and characteristics of unexpected difficult intubation using the IDS. Methods We retrospectively reviewed 951 patients undergoing elective surgery in a single medical center. Patients expected to have a difficult intubation or who had history of difficult intubation were excluded. Each patient was assessed by the IDS scoring system with seven variables. Total prevalence of difficult intubation and the contributing individual factors were further analyzed. Results For the 951 patients, the difficult intubation cases presenting IDS > 5 was 5.8% of total cases (n = 55). The prevalence of Cormack-Lehane Grade 3 or 4 was 16.2% (n = 154). Most of the difficult intubation cases were managed by simple additional maneuvers and techniques such as stylet application, additional lifting force and laryngeal pressure. Conclusions Unexpected difficult airway was present in 5.8% of patients and most was managed effectively. Among the components of IDS, the Cormack-Lehane grade was most sensitive for predicting difficult intubation. PMID:27274369

  3. Crisis management during anaesthesia: difficult intubation.

    PubMed

    Paix, A D; Williamson, J A; Runciman, W B

    2005-06-01

    Anaesthetists may experience difficulty with intubation unexpectedly which may be associated with difficulty in ventilating the patient. If not well managed, there may be serious consequences for the patient. A simple structured approach to this problem was developed to assist the anaesthetist in this difficult situation. To examine the role of a specific sub-algorithm for the management of difficult intubation. The potential performance of a structured approach developed by review of the literature and analysis of each of the relevant incidents among the first 4000 reported to the Australian Incident Monitoring Study (AIMS) was compared with the actual management as reported by the anaesthetists involved. There were 147 reports of difficult intubation capable of analysis among the first 4000 incidents reported to AIMS. The difficulty was unexpected in 52% of cases; major physiological changes occurred in 37% of these cases. Saturation fell below 90% in 22% of cases, oesophageal intubation was reported in 19%, and an emergency transtracheal airway was required in 4% of cases. Obesity and limited neck mobility and mouth opening were the most common anatomical contributing factors. The data confirm previously reported failures to predict difficult intubation with existing preoperative clinical tests and suggest an ongoing need to teach a pre-learned strategy to deal with difficult intubation and any associated problem with ventilation. An easy-to-follow structured approach to these problems is outlined. It is recommended that skilled assistance be obtained (preferably another anaesthetist) when difficulty is expected or the patient's cardiorespiratory reserve is low. Patients should be assessed postoperatively to exclude any sequelae and to inform them of the difficulties encountered. These should be clearly documented and appropriate steps taken to warn future anaesthetists.

  4. Endoscopic Modified Medial Maxillectomy for Resection of an Inverted Papilloma Originating from the Entire Circumference of the Maxillary Sinus

    PubMed Central

    Wada, Kota; Ishigaki, Takashi; Ida, Yutaro; Yamada, Yuki; Hosono, Sachiko; Edamatsu, Hideo

    2015-01-01

    For treatment of a sinonasal inverted papilloma (IP), it is essential to have a definite diagnosis, to identify its origin by computed tomography (CT) and magnetic resonance imaging (MRI), and to select the appropriate surgical approach based on the staging system proposed by Krouse. Recently, a new surgical approach named endoscopic modified medial maxillectomy (EMMM) was proposed. This approach can preserve the inferior turbinate and nasolacrimal duct. We successfully treated sinonasal IP with EMMM in a 71-year-old female patient. In this patient, the sinonasal IP originated from the entire circumference of the maxillary sinus. EMMM is not a difficult procedure and provides good visibility of the operative field. Lacrimation and empty nose syndrome do not occur postoperatively as the nasolacrimal duct and inferior turbinate are preserved. EMMM is considered to be a very favorable approach for treatment of sinonasal IP. PMID:26146581

  5. Videolaryngoscopy versus Fiber-optic Intubation through a Supraglottic Airway in Children with a Difficult Airway: An Analysis from the Multicenter Pediatric Difficult Intubation Registry.

    PubMed

    Burjek, Nicholas E; Nishisaki, Akira; Fiadjoe, John E; Adams, H Daniel; Peeples, Kenneth N; Raman, Vidya T; Olomu, Patrick N; Kovatsis, Pete G; Jagannathan, Narasimhan; Hunyady, Agnes; Bosenberg, Adrian; Tham, See; Low, Daniel; Hopkins, Paul; Glover, Chris; Olutoye, Olutoyin; Szmuk, Peter; McCloskey, John; Dalesio, Nicholas; Koka, Rahul; Greenberg, Robert; Watkins, Scott; Patel, Vikram; Reynolds, Paul; Matuszczak, Maria; Jain, Ranu; Khalil, Samia; Polaner, David; Zieg, Jennifer; Szolnoki, Judit; Sathyamoorthy, Kumar; Taicher, Brad; Riveros Perez, N Ricardo; Bhattacharya, Solmaletha; Bhalla, Tarun; Stricker, Paul; Lockman, Justin; Galvez, Jorge; Rehman, Mohamed; Von Ungern-Sternberg, Britta; Sommerfield, David; Soneru, Codruta; Chiao, Franklin; Richtsfeld, Martina; Belani, Kumar; Sarmiento, Lina; Mireles, Sam; Bilen Rosas, Guelay; Park, Raymond; Peyton, James

    2017-09-01

    The success rates and related complications of various techniques for intubation in children with difficult airways remain unknown. The primary aim of this study is to compare the success rates of fiber-optic intubation via supraglottic airway to videolaryngoscopy in children with difficult airways. Our secondary aim is to compare the complication rates of these techniques. Observational data were collected from 14 sites after management of difficult pediatric airways. Patient age, intubation technique, success per attempt, use of continuous ventilation, and complications were recorded for each case. First-attempt success and complications were compared in subjects managed with fiber-optic intubation via supraglottic airway and videolaryngoscopy. Fiber-optic intubation via supraglottic airway and videolaryngoscopy had similar first-attempt success rates (67 of 114, 59% vs. 404 of 786, 51%; odds ratio 1.35; 95% CI, 0.91 to 2.00; P = 0.16). In subjects less than 1 yr old, fiber-optic intubation via supraglottic airway was more successful on the first attempt than videolaryngoscopy (19 of 35, 54% vs. 79 of 220, 36%; odds ratio, 2.12; 95% CI, 1.04 to 4.31; P = 0.042). Complication rates were similar in the two groups (20 vs. 13%; P = 0.096). The incidence of hypoxemia was lower when continuous ventilation through the supraglottic airway was used throughout the fiber-optic intubation attempt. In this nonrandomized study, first-attempt success rates were similar for fiber-optic intubation via supraglottic airway and videolaryngoscopy. Fiber-optic intubation via supraglottic airway is associated with higher first-attempt success than videolaryngoscopy in infants with difficult airways. Continuous ventilation through the supraglottic airway during fiber-optic intubation attempts may lower the incidence of hypoxemia.

  6. Discovery of unexpected pain in intubated and sedated patients.

    PubMed

    Clukey, Lory; Weyant, Ruth A; Roberts, Melanie; Henderson, Ann

    2014-05-01

    The perceptions of patients who are restrained and sedated while being treated with mechanical ventilation in the intensive care unit are not well understood. The effectiveness of sedation used to aid in recovery and enhance comfort during intubation is unknown. To explore the perceptions of patients who were intubated and receiving pain medication while sedated and restrained in the intensive care unit, in particular, their experience and their memories of the experience. In a phenomenological study, 14 patients who were intubated and receiving pain medication while sedated and restrained were interviewed at the bedside. A semistructured interview guide was used. Data were analyzed by using an inductive method consistent with qualitative research. Three major themes were identified from the data: lack of memory of being restrained; a perception of being intubated as horrific; nursing behaviors that were helpful and comforting. An unexpected discovery was that sedation may be interfering with pain assessment and management. Being intubated can be painful and traumatic despite administration of sedatives and analgesics. Sedation may mask uncontrolled pain for intubated patients and prevent them from communicating this condition to a nurse. Nurses may need to evaluate current interventions in order to provide maximum comfort and promote optimal positive outcomes for intensive care patients who are intubated.

  7. Fiberoptic intubation in 327 neurosurgical patients with lesions of the cervical spine.

    PubMed

    Fuchs, G; Schwarz, G; Baumgartner, A; Kaltenböck, F; Voit-Augustin, H; Planinz, W

    1999-01-01

    In patients with lesions of the cervical spine, direct laryngoscopy for endotracheal intubation entails the risk of injuring the spinal cord. In an attempt to avoid this complication, the authors used flexible fiberoptic nasal intubation in a series of 327 patients with cervical lesions undergoing elective neurosurgical procedures. The nasal route was preferred for laryngeal intubation because it is easier than the oral route and a restraining collar or halo device does not impair the intubating maneuver. Bronchoscopic intubation was possible in all patients. In 12 patients (3.6%), anatomic abnormalities prevented transnasal insertion of the endotracheal tube, and transoral fiberoptic intubation was necessary. Endotracheal intubation was graded as slightly difficult in 85 patients (26%). The minimal peripheral oxygen saturation during intubation exceeded 90% in 289 patients (88%). In the other 38 patients, the mean O2 saturation was 84.2+/-4.3% (range, 72-89%). Intubation was well tolerated by all patients and none had recall of the procedure. Cervical stabilizers did not have to be removed for intubation in any patient. None of the patients had postoperative neurologic deficits attributable to the intubation procedure. The authors consider fiberoptic transnasal intubation to be a useful alternative to direct laryngoscopic tracheal intubation in patients undergoing elective surgical procedures on the cervical spine to avoid potential injury to the cervical spinal cord.

  8. Neurological deterioration during intubation in cervical spine disorders

    PubMed Central

    Durga, Padmaja; Sahu, Barada Prasad

    2014-01-01

    Anaesthesiologists are often involved in the management of patients with cervical spine disorders. Airway management is often implicated in the deterioration of spinal cord function. Most evidence on neurological deterioration resulting from intubation is from case reports which suggest only association, but not causation. Most anaesthesiologists and surgeons probably believe that the risk of spinal cord injury (SCI) during intubation is largely due to mechanical compression produced by movement of the cervical spine. But it is questionable that the small and brief deformations produced during intubation can produce SCI. Difficult intubation, more frequently encountered in patients with cervical spine disorders, is likely to produce greater movement of spine. Several alternative intubation techniques are shown to improve ease and success, and reduce cervical spine movement but their role in limiting SCI is not studied. The current opinion is that most neurological injuries during anaesthesia are the result of prolonged deformation, impaired perfusion of the cord, or both. To prevent further neurological injury to the spinal cord and preserve spinal cord function, minimizing movement during intubation and positioning for surgery are essential. The features that diagnose laryngoscopy induced SCI are myelopathy present on recovery, short period of unconsciousness, autonomic disturbances following laryngoscopy, cranio-cervical junction disease or gross instability below C3. It is difficult to accept or refute the claim that neurological deterioration was induced by intubation. Hence, a record of adequate care at laryngoscopy and also perioperative period are important in the event of later medico-legal proceedings. PMID:25624530

  9. Compression force on the upper jaw during neonatal intubation: mannequin study.

    PubMed

    Doreswamy, Srinivasa Murthy; Almannaei, Khaled; Fusch, Chris; Shivananda, Sandesh

    2015-03-01

    Neonatal intubation is a technically challenging procedure, and pressure-related injuries to surrounding structures have been reported. The primary objective of this study was to determine the pressure exerted on the upper jaw during tracheal intubation using a neonatal mannequin. Multidisciplinary care providers working at a neonatal intensive care unit were requested to intubate a neonatal mannequin using the standard laryngoscope and 3.0-mm (internal diameter) endotracheal tube. Compression force exerted was measured by using pressure-sensitive film taped on the upper jaw before every intubation attempt. Pressure, area under pressure and time taken to intubate were compared between the different types of health-care professionals. Thirty care providers intubated the mannequin three times each. Pressure impressions were observed on the developer film after every intubation attempt (n = 90). The mean pressure exerted during intubation across all health-care providers was 568 kPa (SD 78). The mean area placed under pressure was 142 mm(2) (SD 45), and the mean time taken for intubation was 14.7 s (SD 4.3). There was no difference in pressure exerted on the upper jaw between frequent and less frequent intubators. It was found that pressure greater than 400 kPa was inadvertently applied on the upper jaw during neonatal intubation, far exceeding the 250 kPa shown to cause tissue injury in animal models. The upper jaw is exposed to a significant compression force during intubation. Although such exposure is brief, it has the potential to cause tissue injury. Contact of the laryngoscope blade with the upper jaw occurred in all intubation attempts with the currently used design of laryngoscope. © 2014 The Authors. Journal of Paediatrics and Child Health © 2014 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  10. Intubation of the morbidly obese patient: GlideScope(®) vs. Fastrach™.

    PubMed

    Ydemann, M; Rovsing, L; Lindekaer, A L; Olsen, K S

    2012-07-01

    Several potential problems can arise from airway management in morbidly obese patients, including difficult mask ventilation and difficult intubation. We hypothesised that endotracheal intubation of morbidly obese patients would be more rapid using the GlideScope(®) (GS) (Verathon Inc Corporate Headquarters, Bothell, WA, USA) than with the Fastrach™ (FT) (The Laryngeal Mask Company Ltd, Le Rocher, Victoria, Mahe, Seychelles). One hundred patients who were scheduled for bariatric surgery were randomised to tracheal intubation using either a GS or an FT. The inclusion criteria were age 18-60 years and a body mass index of ≥ 35 kg/m(2) . The primary end point was intubation time, and if intubation was not achieved after two attempts, the other method was used for the third attempt. The mean intubation time was 49 s using the GS and 61 s using the FT (P = 0.86). A total of 92% and 84% of the patients were intubated on the first attempt using the GS and the FT, respectively. One tracheal intubation failed on the second attempt when the GS was used, and five failed on the second attempt when the FT was used. There were no incidents of desaturation and no differences between the groups in terms of mucosal damage or intubation difficulty. We experienced one oesophageal intubation using GS and six oesophageal intubations in five patients using FT. There was no difference between the pain scores or incidence of post-operative hoarseness associated with the two intubation techniques. No significant difference between the two methods was found. The GS and the FT may therefore be considered to be equally good when intubating morbidly obese patients. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

  11. Laryngeal complications by orotracheal intubation: Literature review.

    PubMed

    Mota, Luiz Alberto Alves; de Cavalho, Glauber Barbosa; Brito, Valeska Almeida

    2012-04-01

     The injuries caused for the orotracheal intubation are common in our way and widely told by literature. Generally the pipe rank of or consequence of its permanence in the aerial ways of the patient is caused by accidents in. It has diverse types of larynx injuries, caused for multiple mechanisms.  To verify, in literature, the main causes of laryngeal complications after- orotracheal intubation and its mechanisms of injury. Revision of Literature: The searched databases had been LILACS, BIREME and SCIELO. Were updated, books and theses had been used, delimiting itself the period enters 1953 the 2009. The keywords used for the search of articles had been: complications, injuries, larynx, intubation, endotracheal, orotracheal, granulomas, stenosis. 59 references had been selected. The used criteria of inclusion for the choice of articles had been the ones that had shown to the diverse types of injuries caused for the orotracheal intubation and its pathophysiology.  This revision of literature was motivated by the comment in the practical clinic of a great number of laryngeal sequels in patients submitted to the orotracheal intubation. Of that is ahead important the knowledge, for the professionals of the area of health, the types of complications and its causes, with intention to prevent them, adopting measured of prevention of these injuries.

  12. Rocuronium versus succinylcholine for rapid sequence induction intubation.

    PubMed

    Tran, Diem T T; Newton, Ethan K; Mount, Victoria A H; Lee, Jacques S; Wells, George A; Perry, Jeffrey J

    2015-10-29

    Patients often require a rapid sequence induction (RSI) endotracheal intubation technique during emergencies or electively to protect against aspiration, increased intracranial pressure, or to facilitate intubation. Traditionally succinylcholine has been the most commonly used muscle relaxant for this purpose because of its fast onset and short duration; unfortunately, it can have serious side effects. Rocuronium has been suggested as an alternative to succinylcholine for intubation. This is an update of our Cochrane review published first in 2003 and then updated in 2008 and now in 2015. To determine whether rocuronium creates intubating conditions comparable to those of succinylcholine during RSI intubation. In our initial review we searched all databases until March 2000, followed by an update to June 2007. This latest update included searching the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 2), MEDLINE (1966 to February Week 2 2015), and EMBASE (1988 to February 14 2015 ) for randomized controlled trials (RCTs) or controlled clinical trials (CCTs) relating to the use of rocuronium and succinylcholine. We included foreign language journals and handsearched the references of identified studies for additional citations. We included any RCT or CCT that reported intubating conditions in comparing the use of rocuronium and succinylcholine for RSI or modified RSI in any age group or clinical setting. The dose of rocuronium was at least 0.6 mg/kg and succinylcholine was at least 1 mg/kg. Two authors (EN and DT) independently extracted data and assessed methodological quality for the 'Risk of bias' tables. We combined the outcomes in Review Manager 5 using a risk ratio (RR) with a random-effects model. The previous update (2008) had identified 53 potential studies and included 37 combined for meta-analysis. In this latest update we identified a further 13 studies and included 11, summarizing the results of 50 trials including 4151 participants

  13. Duct Joining System

    DOEpatents

    Proctor, John P.

    2001-02-27

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  14. Duct joining system

    DOEpatents

    Proctor, John P.; deKieffer, Robert C.

    2001-01-01

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  15. Lensing duct

    DOEpatents

    Beach, R.J.; Benett, W.J.

    1994-04-26

    A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding is described. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic. 3 figures.

  16. Tracheal intubation in the emergency department: the Scottish district hospital perspective.

    PubMed

    Stevenson, A G M; Graham, C A; Hall, R; Korsah, P; McGuffie, A C

    2007-06-01

    Tracheal intubation is the accepted gold standard for emergency department (ED) airway management. It may be performed by both anaesthetists and emergency physicians (EPs), with or without drugs. To characterise intubation practice in a busy district general hospital ED in Scotland over 40 months between 2003 and 2006. Crosshouse Hospital, a 450-bed district general hospital serving a mixed urban and rural population; annual ED census 58,000 patients. Prospective observational study using data collection sheets prepared by the Scottish Trauma Audit Group. Proformas were completed at the time of intubation and checked by investigators. Rapid-sequence induction (RSI) was defined as the co-administration of an induction agent and suxamethonium. 234 intubations over 40 months, with a mean of 6 per month. EPs attempted 108 intubations (46%). Six patients in cardiac arrest on arrival were intubated without drugs. 29 patients were intubated after a gas induction or non-RSI drug administration. RSI was performed on 199 patients. Patients with trauma constituted 75 (38%) of the RSI group. 29 RSIs (15%) were immediate (required on arrival at the ED) and 154 (77%) were urgent (required within 30 min of arrival at the ED). EPs attempted RSI in 88 (44%) patients and successfully intubated 85 (97%). Anaesthetists attempted RSI in 111 (56%) patients and successfully intubated 108 (97%). Anaesthetists had a higher proportion of good views at first laryngoscopy and there was a trend to a higher rate of successful intubation at the first attempt for anaesthetists. Complication rates were comparable for the two specialties. Tracheal intubations using RSI in the ED are performed by EPs almost as often as by anaesthetists in this district hospital. Overall success and complication rates are comparable for the two specialties. Laryngoscopy training and the need to achieve intubation at the first (optimum) attempt needs to be emphasised in EP airway training.

  17. Practice of Intubation of the Critically Ill at Mayo Clinic.

    PubMed

    Smischney, Nathan J; Seisa, Mohamed O; Heise, Katherine J; Busack, Kyle D; Loftsgard, Theodore O; Schroeder, Darrell R; Diedrich, Daniel A

    2017-01-01

    To describe the practice of intubation of the critically ill at a single academic institution, Mayo Clinic's campus in Rochester, Minnesota, and to report the incidence of immediate postintubation complications. Critically ill adult (≥18 years) patients admitted to a medical-surgical intensive care unit from January 1, 2013, to December 31, 2014, who required endotracheal intubation included. The final cohort included 420 patients. The mean age at intubation was 62.9 ± 16.3 years, with 58% (244) of the cohort as male. The most common reason for intubation was respiratory failure (282 [67%]). The most common airway device used was video laryngoscopy (204 [49%]). Paralysis was used in 264 (63%) patients, with ketamine as the most common sedative (194 [46%]). The most common complication was hypotension (170 [41%]; 95% confidence interval [CI]: 35.7-45.3) followed by hypoxemia (74 [17.6%]; 95% CI: 14.1-21.6), with difficult intubation occurring in 20 (5%; 95% CI: 2.9-7.3). We found a high success rate of first-pass intubation in critically ill patients (89.8%), despite the procedure being done primarily by trainees 92.6% of the time; video was the preferred method of laryngoscopy (48.6%). Although our difficult intubation (4.8%) and complication rates typically associated with the act of intubation such as aspiration (1.2%; 95% CI: 0.4-2.8) and esophageal intubation (0.2%; 95% CI: 0.01-1.3) are very low compared to other published rates (8.09%), postintubation hypotension (40.5%) and hypoxemia (17.6%) higher.

  18. Randomised controlled trial of thiopental for intubation in neonates

    PubMed Central

    Bhutada, A; Sahni, R; Rastogi, S; Wung, J

    2000-01-01

    AIMS—To determine the effects of premedication with thiopental on heart rate, blood pressure, and oxygen saturation during semi-elective nasotracheal intubation in neonates.
METHODS—A randomised, placebo controlled, non-blinded study design was used to study 30 neonates (mean birthweight 3.27 kg) requiring semi-elective nasotracheal intubation. The babies were randomly allocated to receive either 6 mg/kg of thiopental (study group) or an equivalent volume of physiological saline (control group) one minute before the start of the procedure. Six infants were intubated primarily and 24 were changed from orotracheal to a nasotracheal tube. The electrocardiogram, arterial pressure wave, and transcutaneous oxygen saturation were recorded continuously 10 minutes before, during, and 20 minutes after intubation. Minute by minute measurements of heart rate, heart rate variability, mean blood pressure (MBP) and transcutaneous oxygen saturation (SpO2) were computed. The differences for all of these between the baseline measurements and those made during and after intubation were determined. Differences in the measurements made in the study and the control groups were compared using Student's t test.
RESULTS—During intubation, heart rate increased to a greater degree (12.0 vs−0.5 beats per minute, p < 0.03) and MBP increased to a lesser degree (−2.9 vs 4.4 mm Hg; p < 0.002) in the infants who were premedicated with thiopental. After intubation only the changes in MBP differed significantly between the two groups (−3.8 vs 4.6 mm Hg; p < 0.001). There were no significant changes in the oxygen saturation between the two groups during or after intubation. The time taken for intubation was significantly shorter in the study group (p < 0.04).
CONCLUSIONS—The heart rate and blood pressure of infants who are premedicated with thiopental are maintained nearer to baseline values than those of similar infants who receive no premedication. Whether this lessening of the

  19. Avoiding endotracheal intubation of neonates undergoing laser surgery for retinopathy of prematurity.

    PubMed

    Woodhead, D D; Lambert, D K; Molloy, D A; Schmutz, N; Righter, E; Baer, V L; Christensen, R D

    2007-04-01

    Respiratory support of neonates during and following laser surgery for retinopathy of prematurity (ROP) is commonly accomplished using endotracheal intubation and mechanical ventilation. However, most patients undergoing ROP surgery have been weaned off mechanical ventilation days or weeks before the surgery. When they are electively re-intubated for ROP surgery, it can be difficult to extubate them postoperatively. One of the three level III neonatal intensive care units (NICUs) in the Intermountain Healthcare system initiated a program of using nasopharyngeal prongs, rather than endotracheal intubation, for respiratory support during ROP surgery. We performed an historic cohort analysis of all neonates undergoing ROP surgery during their NICU stay at the three level III NICU's between 1 January 2002 and 31 March 2006. Data collected included birth weight, gestational age at delivery and corrected gestational age at ROP surgery, whether or not they were intubated in the days immediately preceding the ROP surgery, whether or not they were electively intubated for the ROP surgery, the respiratory modality used during and the 3 days following ROP surgery, and all blood gas determinations and respiratory charges during this period. Fifty-four patients underwent ROP surgery during this period. All 23 from NICUs 'A' and 'B' had endotracheal intubation for surgery, while in NICU 'C' 24 were managed using nasopharyngeal prongs. The birth weights of those intubated for surgery (661+/-180 g, mean+/-s.d.) were similar to those not intubated (732+/-180 g). Similarly, the gestational age at birth did not differ between those intubated for surgery (25.2+/-1.3 week) and those not (25.6+/-2.1 week). The day following surgery, 77% (23/30) of those who had been intubated for surgery remained intubated and on mechanical ventilation, whereas only one (4%) of those not intubated for surgery was intubated in the postoperative period (P<0.001). On day 3 following surgery, 50% (15/30) of

  20. Intubation learning curve: comparison between video and direct laryngoscopy by inexperienced students.

    PubMed

    Aghamohammadi, H; Massoudi, N; Fathi, M; Jaffari, A; Gharaei, B; Moshki, A

    2015-01-01

    Background: Direct laryngoscopy (DL) is considered the most common method of tracheal intubation. On the other hand, evidence shows the growing role of video laryngoscopy in danger airway administration. Objectives: Due to the importance of a proper training to accomplish an accurate and fast intubation by the student of anesthesia, this research was conducted to assess the effects of DL and video laryngoscopy (Glidescope VL) training on the success rate of tracheal intubation by low-skill students. Materials/Patients and styles: 50 undergraduate students of anesthesiology took part in this randomized control educational intervention. Having no considerable experience in intubation, they were selected and divided randomly into two equal groups (n = 25); video-laryngoscopy via GlideScope VL and direct laryngoscopy (DL) via a Macintosh blade were prepared by the same experienced anesthesiologist. All the participants practiced intubation six times on the same mannequin within a routine airway situation. The maximum acceptable time for each intubation was 3 minutes and three times of successful intubation was considered as an appropriate intubation skill. The required time for laryngoscopy and intubation at each stage, the grade of glottis view, the reasons for an unsuccessful intubation and the amount of successful intubations were recorded and compared between groups. Results: There was a clear variation between the 2 teams, in all the steps, based on the required time for laryngoscopy and intubation (p = 0.0001). Data analysis was performed by using repeated measures data which demonstrated that the necessary time for laryngoscopy and intubation during the study was clearly lower in the GlideScope VL team (p = .0001). In first five rounds of training, the glottis view in the DL group was significantly better than in the VL group (p < 0.05). Conclusion: Based on the result of today' study, routine airway intubation by using GlideScope VL is significantly faster than

  1. A cost analysis of reusable and disposable flexible optical scopes for intubation.

    PubMed

    Tvede, M F; Kristensen, M S; Nyhus-Andreasen, M

    2012-05-01

    Intubation using a flexible optical scope (FOS) is a cornerstone technique for managing the predicted and unpredicted difficult airway. The term FOS covers both fibre-optic scopes and videoscopes. The total costs of using flexible scopes for intubation are unknown. The recent introduction of a disposable flexible scope for intubation merits closer scrutiny of the total costs associated with both modalities. The costs incurred during intubations using FOSs at a large anaesthesia department were identified, and a series of intubations using a disposable scope were analyzed for comparison. Recognized health-economic methodology was applied. During a 1-year period, 360 FOS intubations were performed. In this clinical setting, the average cost of an intubation using a reusable FOS was €177.7. When using the disposable Ambu(®) aScope (Ambu A/S, Ballerup, Denmark), the cost was €204.4. The break-even point, i.e. the number of intubations per month where the cost of using disposable and non-disposable equipment is identical, was 22.5/month. A subgroup analysis looking solely at intubations performed with flexible videoscopes revealed that the cost per intubation was equal for disposable and reusable videoscopes. At our institution, the total cost of an intubation is greater when using disposable compared with reusable equipment (€204.4 vs. €177.7). If video equipment with an external monitor is considered mandatory, the expenses are of equal magnitude. The cost analysis is particularly sensitive to the actual number of flexible optic intubations performed; with fewer intubations, the total cost will begin to favour disposable equipment. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

  2. [Laryngeal mask for intubation (Fastrach)].

    PubMed

    Añez Simón, C; Boada Pié, S; Solsona Dellá, B

    2000-10-01

    The laryngeal mask for intubation (MLI), or "Fastrach", is a new device designed by Brain for airway management. The MLI, a modified version of the conventional laryngeal mask, allows for blind intubation through the device using endotracheal tubes up to 8 mm in diameter. Insertion with the head in a neutral position makes this system useful for managing the airway when neck injury is present. The device has been used successfully in patients assessed as having difficult-to-manage airways and its use in emergencies inside or outside the hospital is promising. The MLI has been used with high rates of success in combination with other techniques such as fiberoptic bronchoscopy (success rate 99 to 100%) and transillumination (95 to 100% success rate) in patients whose airways have been considered difficult to manage. Given such high rates of success for MLI placement (95 to 100%) and for blind orotracheal intubation (81 to 100%), the Fastrach may offer an alternative to the conventional laryngeal mask in algorithms for airway management.

  3. Management of maxillary sinus inverted papilloma via endoscopic partial medial maxillectomy with an inferior turbinate reversing approach.

    PubMed

    Wang, Feng; Yang, Yang; Wang, Shenqing; Chen, Haihong; Wang, Dehui; Wang, Qinying

    2017-12-01

    The aim of this study is to evaluate the efficacy of endoscopic treatment for maxillary inverted papilloma (IP) through partial medial maxillectomy with an inferior turbinate reversing approach. A retrospective analysis of patients treated in our institution for maxillary sinus IP between July 2011 and August 2015 was performed. Demographics, operative technique, characteristics of tumors, complications, postoperative follow-up, and recurrence were evaluated. Twenty-two patients were enrolled in the study. All tumor attachments were identified intraoperatively. Adequate visualization was obtained following our approach. All inferior turbinate and nasolacrimal ducts were preserved. The median follow-up time was 41 months. One recurrence occurred at the follow-up time of 27 months. Postoperative hemorrhage and numbness at the ipsilateral frontal teeth were reported in two and one patients, respectively. Endoscopic surgery through partial medial maxillectomy using an inferior turbinate reversing approach provides full access to the maxillary sinus and preserves the inferior turbinate and nasolacrimal duct.

  4. Intralacrimal migration of Masterka® stents.

    PubMed

    Fayet, B; Racy, E; Katowitz, W R; Katowitz, J A; Ruban, J-M; Brémond-Gignac, D

    2018-03-01

    Tearing and conjunctivitis in children are commonly due to lacrimal drainage system obstruction. Congenital nasolacrimal obstruction is a common pathology treated by probing with or without silicone stent insertion, depending upon the age of the child. The silicone stent is self-retaining and placed for at least one month. Masterka ® is a recent version of Monoka ® , which may lead to the same surgical complications, such as intralacrimal migration. The medical records of two patients surgically treated with the Masterka ® probe for nasolacrimal duct obstruction, who developed intralacrimal migration of the stent, were retrospectively reviewed and analyzed. A 41-month-old child and an 18-month-old child presented with disappearance of the silicone tube after 7 days and 2 years respectively. In the first case, the tube migrated completely within the lacrimal system and became externalized through the nose at 2 years, while in the second case, the Masterka ® was retrieved through a canalicular approach. In both cases, infants had no further tearing. The frequency self-retaining stent disappearance is estimated at 15%. Among these cases, intralacrimal migration is only reported in 0.5% of cases. To prevent intralacrimal migration, the surgical technique must follow a certain number of rules. Management, based on residual epiphora, is discussed. Prevention of intralacrimal migration of self-retaining stents involves a rigorous analysis of the relationship between the meatus and the fixation head at the time of placement. After lacrimal intubation, scheduled monitoring is necessary to screen for stent disappearance. Management is based on clinical findings, anterior rhinoscopy and even exploratory canaliculotomy. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. Difficult intubation: are you prepared for it?

    PubMed

    Balcom, C

    1994-01-01

    The endotracheal intubation of a patient for surgery requires an anaesthetist who is aided by a skilled and experienced helper. This paper explores reasons why some patients are difficult to intubate. Some are predictable on pre-operative assessment and others are not. Suggestions are given on how the helper is useful to the anaesthetist in this potentially critical situation.

  6. Effect of Use of a Bougie vs Endotracheal Tube and Stylet on First-Attempt Intubation Success Among Patients With Difficult Airways Undergoing Emergency Intubation: A Randomized Clinical Trial.

    PubMed

    Driver, Brian E; Prekker, Matthew E; Klein, Lauren R; Reardon, Robert F; Miner, James R; Fagerstrom, Erik T; Cleghorn, Mitchell R; McGill, John W; Cole, Jon B

    2018-05-16

    The tracheal tube introducer, known as the bougie, is typically used to aid tracheal intubation in poor laryngoscopic views or after intubation attempts fail. The effect of routine bougie use on first-attempt intubation success is unclear. To compare first attempt intubation success facilitated by the bougie vs the endotracheal tube + stylet. The Bougie Use in Emergency Airway Management (BEAM) trial was a randomized clinical trial conducted from September 2016 through August 2017 in the emergency department at Hennepin County Medical Center, an urban, academic department in Minneapolis, Minnesota, where emergency physicians perform all endotracheal intubations. Included patients were 18 years and older who were consecutively admitted to the emergency department and underwent emergency orotracheal intubation with a Macintosh laryngoscope blade for respiratory arrest, difficulty breathing, or airway protection. Patients were randomly assigned to undergo the initial intubation attempt facilitated by bougie (n = 381) or endotracheal tube + stylet (n = 376). The primary outcome was first-attempt intubation success in patients with at least 1 difficult airway characteristic (body fluids obscuring the laryngeal view, airway obstruction or edema, obesity, short neck, small mandible, large tongue, facial trauma, or the need for cervical spine immobilization). Secondary outcomes were first-attempt success in all patients, first-attempt intubation success without hypoxemia, first-attempt duration, esophageal intubation, and hypoxemia. Among 757 patients who were randomized (mean age, 46 years; women, 230 [30%]), 757 patients (100%) completed the trial. Among the 380 patients with at least 1 difficult airway characteristic, first-attempt intubation success was higher in the bougie group (96%) than in the endotracheal tube + stylet group (82%) (absolute between-group difference, 14% [95% CI, 8% to 20%]). Among all patients, first-attempt intubation success

  7. Bile Duct Exploration

    MedlinePlus

    ... Patients & Visitors Health Library Institutes & Departments Home / Health Library / Diagnostics & Testing / Bile Duct Exploration Advertising Policy Bile Duct Exploration Common bile duct exploration is ...

  8. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct...

  9. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system ducts and air duct systems. 25.1103 Section 25.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Induction System § 25.1103 Induction system ducts and air duct...

  10. Hollow lensing duct

    DOEpatents

    Beach, Raymond J.; Honea, Eric C.; Bibeau, Camille; Mitchell, Scott; Lang, John; Maderas, Dennis; Speth, Joel; Payne, Stephen A.

    2000-01-01

    A hollow lensing duct to condense (intensify) light using a combination of focusing using a spherical or cylindrical lens followed by reflective waveguiding. The hollow duct tapers down from a wide input side to a narrow output side, with the input side consisting of a lens that may be coated with an antireflective coating for more efficient transmission into the duct. The inside surfaces of the hollow lens duct are appropriately coated to be reflective, preventing light from escaping by reflection as it travels along the duct (reflective waveguiding). The hollow duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials.

  11. Utilization of virtual reality for endotracheal intubation training.

    PubMed

    Mayrose, James; Kesavadas, T; Chugh, Kevin; Joshi, Dhananjay; Ellis, David G

    2003-10-01

    Tracheal intubation is performed for urgent airway control in injured patients. Current methods of training include working on cadavers and manikins, which lack the realism of a living human being. Work in this field has been limited due to the complex nature of simulating in real-time, the interactive forces and deformations which occur during an actual patient intubation. This study addressed the issue of intubation training in an attempt to bridge the gap between actual and virtual patient scenarios. The haptic device along with the real-time performance of the simulator give it both visual and physical realism. The three-dimensional viewing and interaction available through virtual reality make it possible for physicians, pre-hospital personnel and students to practice many endotracheal intubations without ever touching a patient. The ability for a medical professional to practice a procedure multiple times prior to performing it on a patient will both enhance the skill of the individual while reducing the risk to the patient.

  12. Species-specific characteristics of the biofilm generated in silicone tube: an in vitro study.

    PubMed

    Kim, Dong Ju; Park, Joo-Hee; Chang, Minwook

    2018-04-03

    To investigate characteristics of biofilm which is usually found in silicone tube for nasolacrimal duct surgery and can be the root of chronic bacterial infections eventually resulted in surgical failure. To form a biofilm, sterile silicone tube was placed in culture media of Staphylococcus aureus, Corynebacterium matruchotii, Pseudomonas aeruginosa, or Streptococcus pneumonia. Biofilms formed on these silicone tubes were fixed with 95% ethanol and stained with 0.1% crystal violet. After staining, the optical densities of biofilms were measured using spectrophotometer on a weekly basis for 12 weeks. Staphylococcus aureus group and Pseudomonas aeruginosa group formed significantly more amounts of biofilms compared to the control group. The maximum optical densities of the two groups were found on week 3-4 followed by a tendency of decrease afterwards. However, the amounts of biofilms formed in other groups of silicone tubes were not statistically significant from that of the control group. Bacterial species that could form biofilm on silicone tube included Staphylococcus aureus (week 3) and Pseudomonas aeruginosa (Week 4). It is important to first consider that the cause of infection around 1 month after silicone tube intubation can be Staphylococcus aureus and Pseudomonas aeruginosa.

  13. [Rare bile duct anatomy variant - Right bile duct intraparenchymal junction into the left bile duct].

    PubMed

    Gál, Adrián Róbert; Kalmár-Nagy, Károly; Fincsur, András; Horváth, Örs Péter; Vereczkei, András

    2018-03-01

    The authors present a case of a 67-year-old male patient, who previously had been diagnosed with a malignant liver tumor localized in segment II. He underwent bisegmentectomy (II and III) and partial IV segmentectomy. After the primary surgery jaundice developed, the level of bilirubin increased and after several imaging modalities reoperation was indicated. During the surgery a rare bile duct anatomy variant was found. The right hepatic duct joined the left duct in the parenchyma of the left lobe, and was ligated at the resection. As the liver hilum was not explored, the absence of the right duct was not discovered. Reconstruction of the biliary system was accomplished by a Roux-en-Y loop.

  14. Mammary Duct Ectasia

    MedlinePlus

    ... tenderness or inflammation of the clogged duct (periductal mastitis). Mammary duct ectasia most often occurs in women ... that's turned inward (inverted) A bacterial infection called mastitis also may develop in the affected milk duct, ...

  15. Protocol for rapid sequence intubation in pediatric patients -- a four-year study.

    PubMed

    Marvez-Valls, Eduardo; Houry, Debra; Ernst, Amy A; Weiss, Steven J; Killeen, James

    2002-04-01

    To evaluate a protocol for rapid sequence intubation (RSI) for pediatric patients in a Level 1 trauma center. Retrospective review of prospectively gathered Continuing Quality Improvement (CQI) data at an inner city Level 1 trauma center with an emergency medicine residency program. Protocols for RSI were established prior to initiating the study. All pediatric intubations at the center from February 1996 to February 2000 were included. Statistical analysis included descriptive statistics for categorical data and Chi-square for comparisons between groups. Over the 4-year study period there were 83 pediatric intubations ranging in age from 18 months to 17 years; mean age 8.6. All had data collected at the time of intubation. There were 20 (24%) females and 62 (76%) males (p<0.001). Reasons for intubation were related to trauma in 71 (86%) and medical reasons in 12 (14%) (p<0.001). Of the trauma intubations 7 (10%) were for gunshot wounds, 39 (55%) were secondary to MVCs, and the remainder (25; 35%) were from assaults, falls, and closed head injuries. The non-trauma intubations were for smoke inhalation, overdose, seizure, HIV related complications, eclampsia, and near drowning. Intubations were successful with one attempt in 65 (78%) cases. No surgical airways were necessary. Rocuronium was used in 4 cases. Protocol deviations did not lead to complications. This protocol based pediatric rapid sequence intubation method worked well in an EM residency program. More intubations were in males and more were necessary due to trauma in this group.

  16. Endotracheal Intubation in Neonates: A Prospective Study of Adverse Safety Events in 162 Infants

    PubMed Central

    Hatch, L. Dupree; Grubb, Peter H.; Lea, Amanda S.; Walsh, William F.; Markham, Melinda H.; Whitney, Gina M.; Slaughter, James C.; Stark, Ann R.; Ely, E. Wesley

    2015-01-01

    Objective To determine the rate of adverse events associated with endotracheal intubation in newborns and modifiable factors contributing to these events. Study design We conducted a prospective, observational study in a 100-bed, academic, level IV Neonatal Intensive Care Unit (NICU) from September 2013 through June 2014. We collected data on intubations using standardized data collection instruments with validation by medical record review. Intubations in the delivery or operating rooms were excluded. The primary outcome was an intubation with any adverse event. Adverse events were defined and tracked prospectively as non-severe or severe. We measured clinical variables including number of attempts to successful intubation and intubation urgency (elective, urgent or emergent). We used logistic regression models to estimate the association of these variables with adverse events. Results During the study period, 304 intubations occurred in 178 infants. Data were available for 273 intubations (90%) in 162 patients. Adverse events occurred in 107 (39%) intubations with non-severe and severe events in 96 (35%) and 24 (8.8%) intubations, respectively. Increasing number of intubation attempts (odds ratio [OR] 2.1, 95% confidence intervals [CI], 1.6–2.6) and emergent intubations (OR 4.7, 95% CI, 1.7– 13) were predictors of adverse events. The primary cause of emergent intubations was unplanned extubation (62%). Conclusion Adverse events are common in the NICU, occurring in 4 of 10 intubations. The odds of an adverse event doubled with increasing number of attempts and quadrupled in the emergent setting. Quality improvement efforts to address these factors are needed to improve patient safety. PMID:26541424

  17. High levels of IGF-1 predict difficult intubation of patients with acromegaly.

    PubMed

    Zhang, Yu; Guo, Xiaopeng; Pei, Lijian; Zhang, Zhuhua; Tan, Gang; Xing, Bing

    2017-08-01

    To investigate the characteristics of difficult intubation and identify novel efficient predictors in patients with acromegaly. Patients with either untreated acromegaly or non-functional pituitary adenomas were enrolled. Patients with acromegaly underwent hormone assays, upper airway computed tomography and magnetic resonance imaging examinations and preoperative overnight polysomnography. The modified Mallampati classification, mouth opening, neck circumference, and neck extension were assessed, and the Cormack-Lehane grades and the time of tracheal intubation were recorded. Patients with acromegaly had a higher incidence of difficult intubation (62.5%). The time of tracheal intubation was prolonged, the neck circumference was enlarged, and the neck extension was confined. In patients with acromegaly and difficult intubation, the insulin-like growth factor 1 levels and apnea/hypoxia index were significantly higher compared to patients without difficult intubation (1115.40 ± 253.73 vs. 791.67 ± 206.62 ng/ml, P = 0.020; 22.17 ± 23.25 vs. 2.47 ± 2.84, P = 0.026, respectively). The bilateral regression analysis revealed that high levels of insulin-like growth factor 1 were an independent risk factor for developing difficult intubation (p = 0.042, Exp B = 1.006). The modified Mallampati classification was positively correlated with apnea/hypoxia index and could be calculated using the following logarithmic equation: MMC = 0.2982 * ln (AHI) + 2.1836. In patients with acromegaly, neck movement is confined, the time of tracheal intubation is prolonged, and the neck circumference is enlarged, and these patients suffer from an increased incidence of difficult intubation (62.5%) during anesthesia induction. The apnea/hypoxia index and insulin-like growth factor 1 levels are both increased in acromegalic patients with difficult intubation, and elevated insulin-like growth factor 1 levels are an independent risk factor of difficult

  18. Timing of intubation and ventilator-associated pneumonia following injury.

    PubMed

    Evans, Heather L; Zonies, David H; Warner, Keir J; Bulger, Eileen M; Sharar, Sam R; Maier, Ronald V; Cuschieri, Joseph

    2010-11-01

    In an emergency medical system with established rapid-sequence intubation protocols, prehospital (PH) intubation of patients with trauma is not associated with a higher rate of ventilator-associated pneumonia (VAP) than emergency department (ED) intubation. Retrospective observational cohort. Level I trauma center. Adult patients with trauma intubated in a PH or an ED setting from July 1, 2007, through July 31, 2008. Diagnosis of VAP by means of bronchoscopic alveolar lavage or clinical assessment when bronchoscopic alveolar lavage was impossible. Secondary outcomes included time to VAP, length of hospitalization, and in-hospital mortality. Of 572 patients, 412 (72.0%) underwent PH intubation. The ED group was older than the PH group (mean ages, 46.4 vs 39.1 years; P < .001) and had a higher incidence of blunt injury (142 [88.8%] vs 322 [78.2%]; P = .002). The mean (SD) lowest recorded ED systolic blood pressure was lower in the ED group (102.8 [1.9] vs 111.4 [1.2] mm Hg; P < .001), despite similar mean injury severity scores in both groups (27.2 [0.7] vs 27.0 [1.1]; P = .94). There was no difference in the mean rate of VAP (30 [18.8%] vs 71 [17.2%]; P = .66) or mean time to diagnosis (8.1 [1.2] vs 7.8 [1.0] days; P = .89). Logistic regression analysis identified history of drug abuse, lowest recorded ED systolic blood pressure, and injury severity score as 3 independent factors predictive of VAP. Prehospital intubation of patients with trauma is not associated with higher risk of VAP. Further investigation of intubation factors and the incidence and timing of aspiration is required to identify potentially modifiable factors to prevent VAP.

  19. Impact of System-Wide King LT Airway Implementation on Orotracheal Intubation.

    PubMed

    Hilton, Michael T; Wayne, Max; Martin-Gill, Christian

    2016-01-01

    Orotracheal intubation is a key component of prehospital airway management and success rates are dependent on procedural experience. Supraglottic airway devices are increasingly being used in the prehospital setting. As a result, paramedics may have fewer opportunities for performing intubation, limiting their proficiency in the procedure. We aimed to determine the trends in intubation versus supraglottic airway use over an 8 year period. We also aimed to determine the association between system-wide introduction of King LT guidelines and ETI success rates. We performed a retrospective observational study of 37 Emergency Medical Services (EMS) agencies in a 10 county region of Southwestern Pennsylvania. Cases between January 1, 2005 and December 31, 2012 were included if an advanced airway procedure was performed. We determined trends in advanced airway placement and compared the proportion of cases with first pass intubation success before and after the King LT was introduced and promoted by statewide protocol starting in 2007. Use of airway devices before and after King LT implementation were presented using descriptive statistics and compared using Pearson's Chi-square or Fishers Exact test as appropriate. We compared first pass success rate of orotracheal intubation between study periods using multivariable logistic regression, controlling for other factors that may impact success of orotracheal intubation (year, EMS agency, age category, traumatic injury, and cardiac arrest). There were 712 cases of orotracheal intubation before and 2,835 cases after introduction of the King LT. The proportion of cases ultimately managed with orotracheal intubation before and after 2007 decreased from 72.3% (95% CI 68.9-75.6%) to 67.1% (95% CI 65.3-68.8%) (p = 0.007). In the multivariable analysis, success of orotracheal intubation was not associated with implementation of the King LT airway (OR 1.02, 95% CI 0.74-1.41). Fewer patients with advanced airway management received

  20. Thirty years of submental intubation: a review.

    PubMed

    Lim, D; Ma, B C; Parumo, R; Shanmuhasuntharam, P

    2018-05-03

    Submental intubation has been used as an alternative to conventional intubation in the field of oral and maxillofacial surgery since its introduction by Francisco Hernández Altemir in 1986. A review of submental intubation was performed using data from all case reports, case-series, and prospective and retrospective studies published between 1986 and 2016. The indications, variations in incision length, incision sites, types of endotracheal tube used, methods of exteriorization, and complications were recorded and analyzed. A total of 70 articles reporting 1021 patients were included. The main indication was maxillofacial trauma (86.9%, n=887), followed by orthognathic surgery (5.8%, n=59), skull base surgery (2.8%, n=29), and rhinoplasty and rhytidectomy (1.5%, n=15). The complication rate was relatively low: 91.0% of patients (n=929) were complication-free. The most common complication was infection, occurring in 3.5% (n=36) of the total number of patients, followed by scarring (1.2%, n=12) and formation of an orocutaneous or salivary fistula (1.1%, n=11). In summary, submental intubation is a good alternative airway with minimal complications. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Video laryngoscopy vs. direct laryngoscopy: Which should be chosen for endotracheal intubation during cardiopulmonary resuscitation? A prospective randomized controlled study of experienced intubators.

    PubMed

    Kim, Jong Won; Park, Sang O; Lee, Kyeong Ryong; Hong, Dae Young; Baek, Kwang Je; Lee, Young Hwan; Lee, Jeong Hun; Choi, Pil Cho

    2016-08-01

    This study compared endotracheal intubation (ETI) performance during cardiopulmonary resuscitation (CPR) between direct laryngoscopy (DL) and video laryngoscopy (VL) (GlideScope(®)) by experienced intubators (>50 successful ETIs). This was a prospective randomized controlled study conducted in an emergency department between 2011 and 2013. Intubators who used DL or VL were randomly allocated to ETI during CPR. Data were collected from recorded video clips and rhythm sheets. The success, speed, complications, and chest compressions interruption were compared between the two devices. Total 140 ETIs by experienced intubators using DL (n=69) and VL (n=71) were analysed. There were no significant differences between DL and VL in the ETI success rate (92.8% vs. 95.8%; p=0.490), first-attempt success rate (87.0% vs. 94.4%; p=0.204), and median time to complete ETI (51 [36-67] vs. 42 [34-62]s; p=0.143). In both groups, oesophageal intubation and dental injuries seldom occurred. However, longer chest compressions interruption occurred using DL (4.0 [1.0-11.0]s) compared with VL (0.0 [0.0-1.0]s) and frequent serious no-flow (interruption>10s) occurred with DL (18/69 [26.1%]) compared with VL (0/71) (p<0.001). For highly experienced intubators (>80 successful ETIs), frequent serious no-flow occurred in DL (14/55 [25.5%] vs. 0/57 in VL). The ETI success, speed and complications during CPR did not differ significantly between the two devices for experienced intubators. However, the VL was superior in terms of completion of ETI without chest compression interruptions. Clinical Research Information Service (CRIS) in South Korea KCT0000849. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. The usefulness of design of experimentation in defining the effect difficult airway factors and training have on simulator oral-tracheal intubation success rates in novice intubators.

    PubMed

    Thomas, Frank; Carpenter, Judi; Rhoades, Carol; Holleran, Renee; Snow, Gregory

    2010-04-01

    This exploratory study examined novice intubators and the effect difficult airway factors have on pre- and posttraining oral-tracheal simulation intubation success rates. Using a two-level, full-factorial design of experimentation (DOE) involving a combination of six airway factors (curved vs. straight laryngoscope blade, trismus, tongue edema, laryngeal spasm, pharyngeal obstruction, or cervical immobilization), 64 airway scenarios were prospectively randomized to 12 critical care nurses to evaluate pre- and posttraining first-pass intubation success rates on a simulator. Scenario variables and intubation outcomes were analyzed using a generalized linear mixed-effects model to determine two-way main and interactive effects. Interactive effects between the six study factors were nonsignificant (p = 0.69). For both pre- and posttraining, main effects showed the straight blade (p = 0.006), tongue edema (p = 0.0001), and laryngeal spasm (p = 0.004) significantly reduced success rates, while trismus (p = 0.358), pharyngeal obstruction (p = 0.078), and cervical immobilization did not significantly change the success rate. First-pass intubation success rate on the simulator significantly improved (p = 0.005) from pre- (19%) to posttraining (36%). Design of experimentation is useful in analyzing the effect difficult airway factors and training have on simulator intubation success rates. Future quality improvement DOE simulator research studies should be performed to help clarify the relationship between simulator factors and patient intubation rates.

  3. Duct closure

    DOEpatents

    Vowell, Kennison L.

    1987-01-01

    A closure for an inclined duct having an open upper end and defining downwardly extending passageway. The closure includes a cap for sealing engagement with the open upper end of the duct. Associated with the cap are an array of vertically aligned plug members, each of which has a cross-sectional area substantially conforming to the cross-sectional area of the passageway at least adjacent the upper end of the passageway. The plug members are interconnected in a manner to provide for free movement only in the plane in which the duct is inclined. The uppermost plug member is attached to the cap means and the cap means is in turn connected to a hoist means which is located directly over the open end of the duct.

  4. Emergency Department Intubation Success With Succinylcholine Versus Rocuronium: A National Emergency Airway Registry Study.

    PubMed

    April, Michael D; Arana, Allyson; Pallin, Daniel J; Schauer, Steven G; Fantegrossi, Andrea; Fernandez, Jessie; Maddry, Joseph K; Summers, Shane M; Antonacci, Mark A; Brown, Calvin A

    2018-05-07

    Although both succinylcholine and rocuronium are used to facilitate emergency department (ED) rapid sequence intubation, the difference in intubation success rate between them is unknown. We compare first-pass intubation success between ED rapid sequence intubation facilitated by succinylcholine versus rocuronium. We analyzed prospectively collected data from the National Emergency Airway Registry, a multicenter registry collecting data on all intubations performed in 22 EDs. We included intubations of patients older than 14 years who received succinylcholine or rocuronium during 2016. We compared the first-pass intubation success between patients receiving succinylcholine and those receiving rocuronium. We also compared the incidence of adverse events (cardiac arrest, dental trauma, direct airway injury, dysrhythmias, epistaxis, esophageal intubation, hypotension, hypoxia, iatrogenic bleeding, laryngoscope failure, laryngospasm, lip laceration, main-stem bronchus intubation, malignant hyperthermia, medication error, pharyngeal laceration, pneumothorax, endotracheal tube cuff failure, and vomiting). We conducted subgroup analyses stratified by paralytic weight-based dose. There were 2,275 rapid sequence intubations facilitated by succinylcholine and 1,800 by rocuronium. Patients receiving succinylcholine were younger and more likely to undergo intubation with video laryngoscopy and by more experienced providers. First-pass intubation success rate was 87.0% with succinylcholine versus 87.5% with rocuronium (adjusted odds ratio 0.9; 95% confidence interval 0.6 to 1.3). The incidence of any adverse event was also comparable between these agents: 14.7% for succinylcholine versus 14.8% for rocuronium (adjusted odds ratio 1.1; 95% confidence interval 0.9 to 1.3). We observed similar results when they were stratified by paralytic weight-based dose. In this large observational series, we did not detect an association between paralytic choice and first-pass rapid sequence

  5. Difficult airway simulator intubation success rates using Commission on Accreditation of Medical Transport systems training standards.

    PubMed

    Thomas, Frank; Rhoades, Carol; Carpenter, Judi; Holleran, Renee; Handrahan, Diana

    2011-01-01

    This study was undertaken to evaluate difficult airway simulator intubation success rates using Commission on Accreditation of Medical Transport Systems (CAMTS) initial and maintenance intubation training standards on transport-RN novice intubators over a 1-year period. Twelve transport nurses were blinded to and randomly assigned five or six of 64 different difficult airway simulator scenarios. Intubation success rates were measured 1 month before training, 1 month after training, and 1 year later, following CAMTS initial and maintenance intubation standards. Outcome measurements included first attempt intubation rate, overall intubation success rate, number of attempts to intubation, time per attempt, time to intubation, and time between attempts. During the study, participants received no additional training or opportunities to intubate. First-attempt intubation rates significantly improved (P 5 .022) from 19% 1 month before training to 36% 1 month after training, but did not significantly change (P > .999) 1 year later following CAMTS maintenance standards (34%). Mean cumulative success rates did not significantly improve after four attempts or after 3.5 minutes. The overall mean time per attempt and time between attempts declined with subsequent intubation attempts. Using initial and maintenance CAMTS standards, simulator difficult airway intubation success rates are low in novice intubators. Our results suggest that one intubation/quarter may be enough to maintain difficult airway intubation success rates. Training significantly improves intubation rates. Little advantage occurs in intubation rates after four attempts or 3.5 minutes. Copyright © 2011 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  6. Advanced Duct Sealing Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, Max H.; Walker, Iain S.

    Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with naturalmore » rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were

  7. Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in children (excluding neonates).

    PubMed

    Abdelgadir, Ibtihal S; Phillips, Robert S; Singh, Davinder; Moncreiff, Michael P; Lumsden, Joanne L

    2017-05-24

    Direct laryngoscopy is the method currently used for tracheal intubation in children. It occasionally offers unexpectedly poor laryngeal views. Indirect laryngoscopy involves visualizing the vocal cords by means other than obtaining a direct sight, with the potential to improve outcomes. We reviewed the current available literature and performed a meta-analysis to compare direct versus indirect laryngoscopy, or videolaryngoscopy, with regards to efficacy and adverse effects. To assess the efficacy of indirect laryngoscopy, or videolaryngoscopy, versus direct laryngoscopy for intubation of children with regards to intubation time, number of attempts at intubation, and adverse haemodynamic responses to endotracheal intubation. We also assessed other adverse responses to intubation, such as trauma to oral, pharyngeal, and laryngeal structures, and we assessed vocal cord view scores. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), and trial registers (www.clinicaltrials.gov and www.controlledtrials) in November 2015. We reran the search in January 2017. We added new studies of potential interest to a list of 'Studies awaiting classification' and will incorporate them into formal review findings during the review update. We performed reference checking and citation searching and contacted the authors of unpublished data to ask for more information. We applied no language restrictions. We included only randomized controlled trials. Participants were children aged 28 days to 18 years. Investigators performed intubations using any type of indirect laryngoscopes, or videolaryngoscopes, versus direct laryngoscopes. We used Cochrane standard methodological procedures. Two review authors independently reviewed titles, extracted data, and assessed risk of bias. We included 12 studies (803 children) in this review and meta-analysis. We identified three studies that

  8. BMI as a Predictor for Potential Difficult Tracheal Intubation in Males.

    PubMed

    Uribe, Alberto A; Zvara, David A; Puente, Erika G; Otey, Andrew J; Zhang, Jianying; Bergese, Sergio D

    2015-01-01

    Difficult tracheal intubation is a common source of mortality and morbidity in surgical and critical care settings. The incidence reported of difficult tracheal intubation is 0.1%-13% and reaches 14% in the obese population. The objective of our retrospective study was to investigate and compare the utility of body mass index (BMI) as indicator of difficult tracheal intubation in males and females. We performed a retrospective chart review of patients who underwent abdominal surgeries with American Society of Anesthesiologists I to V under general anesthesia requiring endotracheal intubation. The following information was obtained from medical records for analysis: gender, age, height, weight, BMI, length of patient stay in the Post Anesthesia Care Unit, past medical history of sleep apnea, Mallampati score, and the American Society of Anesthesiologists classification assigned by the anesthesia care provider performing the endotracheal intubation. Of 4303 adult patients, 1970 (45.8%) men and 2333 (54.2%) women were enrolled in the study. Within this group, a total of 1673 (38.9%) patients were morbidly obese. The average age of the study group was 51.4 ± 15.8 and the average BMI was 29.7 ± 8.2 kg/m(2). The overall incidence of the encountered difficult intubations was 5.23% or 225 subjects. Thus, our results indicate that BMI is a reliable predictor of difficult tracheal intubation predominantly in the male population; another strong predictor, with a positive linear correlation, being the Mallampati score. In conclusion, our data shows that BMI is a reliable indicator of potential difficult tracheal intubation only in male surgical patients.

  9. Graft versus host disease: what should the oculoplastic surgeon know?

    PubMed

    Tung, Cynthia I

    2017-09-01

    To provide a concise review of the oculoplastic manifestations of ocular graft versus host disease (GVHD), and to discuss their management. Ocular GVHD occurs as a common immune-mediated complication of hematopoietic stem cell transplantation that presents as a Stevens-Johnson-like syndrome in the acute phase or a Sjögren-like syndrome in the chronic phase. Cicatricial conjunctivitis may be underreported in ocular GVHD. The spectrum of oculoplastic manifestations includes GVHD of the skin, cicatricial entropion, nasolacrimal duct obstruction, and lacrimal gland dysfunction. Surgical treatment is indicated for patients with significant corneal complications from entropion. Surgical approach to repair of nasolacrimal duct obstruction is presented in this review, including modified approaches for treating patients at risk for keratitis sicca. Management of the ocular graft versus host patient may require a multidisciplinary approach involving collaboration from the oculoplastic surgeon, the corneal specialist, and the stem cell transplant physician. Oculoplastic manifestations of ocular GVHD typically present as cicatricial changes in the eyelid and lacrimal system. Careful oculoplastic and corneal evaluation are necessary when considering surgical management for the ocular GVHD patient.

  10. Ventilation-associated pneumonia after intubation in the prehospital or the emergency unit.

    PubMed

    Decelle, Lydie; Thys, Frédéric; Zech, Francis; Verschuren, Franck

    2013-02-01

    The aim of the study was to evaluate the prevalence and the risk factors of ventilation-associated pneumonia (VAP) for out-of-hospital or in the emergency department intubated patients. This was a retrospective descriptive study. All intubated adults subsequently admitted to the ICU over 1-year period were included. Among 75 patients, 15 patients developed VAP (20%; 95% CI 12-31%). A multivariate analysis revealed three variables independently associated with VAP: cardiorespiratory arrest as the reason of intubation (P=0.001), out-of-hospital as the location of intubation (P=0.011), and clinical macroaspiration as clinical characteristic at the time of intubation (P=0.024). Death rate was 17% and was not significantly higher for patients with VAP (P=0.9; 95% CI 0.32-4.95%). Emergency care workers should be aware of the potential 20% occurrence of VAP when they intubate and ventilate a patient. Preventive strategies, which have been proven effective in ICUs, should be implemented in the emergency setting.

  11. Scissors Duct

    NASA Image and Video Library

    2007-06-26

    Stennis Space Center engineers are preparing to conduct water tests on an updated version of the scissors duct component of the J-2X engine. Measuring about 2 feet long and about 8 inches in diameter, the duct on the J-2X predecessor, the J-2, connected its fuel turbo pumps to the flight vehicle's upper stage run tanks. According to NASA's J-2X project manager at SSC, Gary Benton, the water tests should establish the limits of the duct's ability to withstand vibration.

  12. A comparison of blind nasotracheal and succinylcholine-assisted intubation in the poisoned patient.

    PubMed

    Dronen, S C; Merigian, K S; Hedges, J R; Hoekstra, J W; Borron, S W

    1987-06-01

    In the patient obtunded by drug intoxication, the optimal method of airway protection prior to gastric emptying is not clear. We report a prospective randomized trial of two methods of intubation in this patient population. Fifty-two overdose patients with Glascow Coma Scale scores of 12 or less were intubated either orotracheally after succinylcholine administration or nasotracheally. Success rate, time to intubate, difficulty, and complications of intubation were compared for the two groups. We found a success rate of 100% (23 of 23) for succinylcholine assisted intubation (SAI) versus 65% (19 of 29) success with blind nasotracheal intubation (BNI). Mean time to intubate was 64 seconds and 276 seconds in the SAI and BNI groups, respectively. Eighty-six percent (19 of 22) of patients were intubated successfully in less than 120 seconds in the SAI group versus 37% (10 of 27) in the BNI group (P less than .005). In the SAI group, the mean number of attempts was 1.3 per patient, (range, one to three) with 96% (22 of 23) having two or fewer attempts. No complications were identified. In the BNI group, the mean number of attempts was 3.7 per patient, (range, one to 13) with 45% (13 of 29) having two or fewer attempts (P less than .005). Sixty-nine percent of the BNI group experienced epistaxis, 17% had vomiting, and 10% aspirated. We conclude that SAI is a safe and effective method of airway protection in the obtunded poisoned patient. Complications and difficulty in intubation were significantly less with SAI than with blind nasotracheal intubation.

  13. The Process of Prehospital Airway Management: Challenges and Solutions During Paramedic Endotracheal Intubation

    PubMed Central

    Prekker, Matthew E.; Kwok, Heemun; Shin, Jenny; Carlbom, David; Grabinsky, Andreas; Rea, Thomas D.

    2016-01-01

    Objective Endotracheal intubation success rates in the prehospital setting are variable. Our objective was to describe the challenges encountered and corrective actions taken during the process of endotracheal intubation by paramedics. Design Analysis of prehospital airway management using a prospective registry that was linked to an emergency medical services (EMS) administrative database. Setting EMS system serving King County, Washington, 2006-2011. Paramedics in this system have the capability to administer neuromuscular blocking agents to facilitate intubation (i.e. rapid sequence intubation). Patients A total of 7,523 patients >12 years old in whom paramedics attempted prehospital endotracheal intubation. Interventions None Measurements and Main Results An intubation attempt was defined as the introduction of the laryngoscope into the patient's mouth, and the attempt concluded when the laryngoscope was removed from the mouth. Endotracheal intubation was successful on the first attempt in 77% and ultimately successful in 99% of patients (7,433 of 7,523). Paramedics used a rapid sequence intubation strategy on 54% of first attempts. Among the subset with a failed first attempt (N=1,715), bodily fluids obstructing the laryngeal view (50%), obesity (28%), patient positioning (17%), and facial or spinal trauma (6%) were identified as challenges to intubation. A variety of adjustments were made to achieve intubation success, including upper airway suctioning (used in 43% of attempts resulting in success), patient repositioning (38%), rescue bougie use (19%), operator change (16%), and rescue rapid sequence intubation (6%). Surgical cricothyrotomy (0.4%, N=27) and bag-valve-mask ventilation (0.8%, N=60) were rarely performed by paramedics as final rescue airway strategies. Conclusions Airway management in the prehospital setting has substantial challenges. Success can require a collection of adjustments that involve equipment, personnel, and medication often in a

  14. The process of prehospital airway management: challenges and solutions during paramedic endotracheal intubation.

    PubMed

    Prekker, Matthew E; Kwok, Heemun; Shin, Jenny; Carlbom, David; Grabinsky, Andreas; Rea, Thomas D

    2014-06-01

    Endotracheal intubation success rates in the prehospital setting are variable. Our objective was to describe the challenges encountered and corrective actions taken during the process of endotracheal intubation by paramedics. Analysis of prehospital airway management using a prospective registry that was linked to an emergency medical services administrative database. Emergency medical services system serving King County, Washington, 2006-2011. Paramedics in this system have the capability to administer neuromuscular blocking agents to facilitate intubation (i.e., rapid sequence intubation). A total of 7,523 patients more than 12 years old in whom paramedics attempted prehospital endotracheal intubation. None. An intubation attempt was defined as the introduction of the laryngoscope into the patient's mouth, and the attempt concluded when the laryngoscope was removed from the mouth. Endotracheal intubation was successful on the first attempt in 77% and ultimately successful in 99% of patients (7,433 of 7,523). Paramedics used a rapid sequence intubation strategy on 54% of first attempts. Among the subset with a failed first attempt (n = 1,715), bodily fluids obstructing the laryngeal view (50%), obesity (28%), patient positioning (17%), and facial or spinal trauma (6%) were identified as challenges to intubation. A variety of adjustments were made to achieve intubation success, including upper airway suctioning (used in 43% of attempts resulting in success), patient repositioning (38%), rescue bougie use (19%), operator change (16%), and rescue rapid sequence intubation (6%). Surgical cricothyrotomy (0.4%, n = 27) and bag-valve-mask ventilation (0.8%, n = 60) were rarely performed by paramedics as final rescue airway strategies. Airway management in the prehospital setting has substantial challenges. Success can require a collection of adjustments that involve equipment, personnel, and medication often in a simultaneous fashion.

  15. Acromegaly and papillomatosis: difficult intubation and use of the airway exchange catheter.

    PubMed

    Hulme, G J; Blues, C M

    1999-08-01

    We describe the anaesthetic management of a patient with acromegaly scheduled for transsphenoidal resection of a pituitary tumour who was found at intubation to have coexisting laryngeal papillomatosis. Oral intubation was impossible using both direct and fibreoptic techniques. Nasal fibreoptic intubation was successful but precluded the transsphenoidal approach to surgery. A Cook Airway Exchange Catheter [Cook (UK) Ltd, Monroe House, Letchworth SG6 1LN] was used with a Negus bronchoscope to convert to oral intubation and allow completion of surgery without resort to tracheostomy.

  16. Failed Endotracheal Intubation and Adverse Outcomes Among Extremely Low Birth Weight Infants

    PubMed Central

    Wallenstein, Matthew B.; Birnie, Krista L.; Arain, Yassar H.; Yang, Wei; Yamada, Nicole K.; Huffman, Lynne C.; Palma, Jonathan P.; Chock, Valerie Y.; Shaw, Gary M.; Stevenson, David K.

    2015-01-01

    OBJECTIVE To quantify the importance of successful endotracheal intubation on the first attempt among extremely low birth weight (ELBW) infants who require resuscitation after delivery. STUDY DESIGN A retrospective chart review was conducted for all ELBW infants ≤1000 g born between January 2007 and May 2014 at a level IV neonatal intensive care unit. Infants were included if intubation was attempted during the first five minutes of life, or if intubation was attempted during the first 10 minutes of life with heart rate < 100. The primary outcome was death or neurodevelopmental impairment. The association between successful intubation on the first attempt and the primary outcome was assessed using multivariable logistic regression with adjustment for birth weight, gestational age, gender, and antenatal steroids. RESULTS The study sample included 88 ELBW infants. Forty-percent were intubated on the first attempt and 60% required multiple intubation attempts. Death or neurodevelopmental impairment occurred in 29% of infants intubated on the first attempt, compared to 53% of infants that required multiple attempts, adjusted odds ratio 0.4 (95% confidence interval 0.1 - 1.0), p < 0.05. CONCLUSION Successful intubation on the first attempt is associated with improved neurodevelopmental outcomes among ELBW infants. This study confirms the importance of rapid establishment of a stable airway in ELBW infants requiring resuscitation after birth and has implications for personnel selection and role assignment in the delivery room. PMID:26540244

  17. Pediatric Intubation by Paramedics in a Large Emergency Medical Services System: Process, Challenges, and Outcomes.

    PubMed

    Prekker, Matthew E; Delgado, Fernanda; Shin, Jenny; Kwok, Heemun; Johnson, Nicholas J; Carlbom, David; Grabinsky, Andreas; Brogan, Thomas V; King, Mary A; Rea, Thomas D

    2016-01-01

    Pediatric intubation is a core paramedic skill in some emergency medical services (EMS) systems. The literature lacks a detailed examination of the challenges and subsequent adjustments made by paramedics when intubating children in the out-of-hospital setting. We undertake a descriptive evaluation of the process of out-of-hospital pediatric intubation, focusing on challenges, adjustments, and outcomes. We performed a retrospective analysis of EMS responses between 2006 and 2012 that involved attempted intubation of children younger than 13 years by paramedics in a large, metropolitan EMS system. We calculated the incidence rate of attempted pediatric intubation with EMS and county census data. To summarize the intubation process, we linked a detailed out-of-hospital airway registry with clinical records from EMS, hospital, or autopsy encounters for each child. The main outcome measures were procedural challenges, procedural success, complications, and patient disposition. Paramedics attempted intubation in 299 cases during 6.3 years, with an incidence of 1 pediatric intubation per 2,198 EMS responses. Less than half of intubations (44%) were for patients in cardiac arrest. Two thirds of patients were intubated on the first attempt (66%), and overall success was 97%. The most prevalent challenge was body fluids obscuring the laryngeal view (33%). After a failed first intubation attempt, corrective actions taken by paramedics included changing equipment (33%), suctioning (32%), and repositioning the patient (27%). Six patients (2%) experienced peri-intubation cardiac arrest and 1 patient had an iatrogenic tracheal injury. No esophageal intubations were observed. Of patients transported to the hospital, 86% were admitted to intensive care and hospital mortality was 27%. Pediatric intubation by paramedics was performed infrequently in this EMS system. Although overall intubation success was high, a detailed evaluation of the process of intubation revealed specific

  18. User's Manual for DuctE3D: A Program for 3D Euler Unsteady Aerodynamic and Aeroelastic Analysis of Ducted Fans

    NASA Technical Reports Server (NTRS)

    Srivastava, R.; Reddy, T. S. R.

    1997-01-01

    The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.

  19. Patients with difficult intubation may need referral to sleep clinics.

    PubMed

    Chung, Frances; Yegneswaran, Balaji; Herrera, Francisco; Shenderey, Alex; Shapiro, Colin M

    2008-09-01

    Upper airway abnormalities carry the risk of obstructive sleep apnea (OSA) and difficult tracheal intubations. Both conditions contribute to significant clinical problems and have increased perioperative morbidity and mortality. We hypothesized that patients who presented with difficult intubation would have a very high prevalence of OSA and that those with unexpected difficult intubation may require referral to sleep clinics for polysomnography (PSG). Patients classified as a grade 4 Cormack and Lehane on direct laryngoscopic view, and who required more than two attempts for successful endotracheal intubation, were referred to the study by consultant anesthesiologists at four hospitals. Apnea-hypopnea index (AHI) data and postoperative events were collected. Patients with AHI >5/h were considered positive for OSA. Clinical and PSG variables were compared using t-tests and chi(2) test. Over a 20-mo period, 84 patients with a difficult intubation were referred into the study. Thirty-three patients agreed to participate. Sixty-six percent (22 of 33) had OSA (AHI >5/h). Of the 22 OSA patients, 10 patients (64%) had mild OSA (AHI 5-15), 6 (18%) had moderate OSA (AHI >15/h), and 6 (18%) had severe OSA (AHI >30/h). Of the 33 patients, 11 patients (33%) were recommended for continuous positive airway pressure treatment. Between the OSA group and the non-OSA group, there were significant differences in gender, neck size, and the quality of sleep, but there were no significant differences in age and body mass index. Sixty-six percent of patients with unexpected difficult intubation who consented to undergo a sleep study were diagnosed with OSA by PSG. Patients with difficult intubation are at high risk for OSA and should be screened for signs and symptoms of sleep apnea. Screening for OSA should be considered by referral to a sleep clinic for PSG.

  20. Developing flow in S-shaped ducts. 2: Circular cross-section duct

    NASA Technical Reports Server (NTRS)

    Taylor, A. M. K. P.; Whitelaw, J. H.; Yianneskis, M.

    1984-01-01

    Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.

  1. Using the phacoemulsification crescent knife in dacryocystorhinostomy.

    PubMed

    Fong, K S; Koh, A H; Choo, C T

    1998-04-01

    Dacryocystorhinostomy is an effective treatment for nasolacrimal duct obstruction. Most techniques employ a conventional blade or knife in making the incision of the nasal mucosa and lacrimal sac. The authors describe the use of a phacoemulsification crescent knife for this purpose. This technique can be effective and at the same time safer and easier to perform.

  2. Epiphora associated with dacryops in a dog.

    PubMed

    Grahn, B H; Mason, R A

    1995-01-01

    A six-month-old basset hound was presented with unilateral right epiphora and medial canthal and maxillary bone swelling. Skull radiographs and dacryocystorhinography revealed a nasal cyst, right nasolacrimal duct dilatation, and obstruction. Laboratory examination of the cyst confirmed the diagnosis of dacryops, a cyst of lacrimal gland origin. The cyst was treated successfully with surgical drainage and curettage.

  3. [Tracheal Intubation by Paramedics in a Local Community: Current Situation and Future Challenges].

    PubMed

    Takinami, Yoshikazu

    2016-03-01

    As of April 2013, 164 paramedics are certified to perform tracheal intubation in Fukui Prefecture. This study investigated the current situation surrounding tracheal intubation performed by paramedics in prehospital care. Subjects were 58 paramedics who completed practical training at our hospital. Post-training duration, number of tracheal intubation cases, number of attempts before successful tracheal intubation, disease involved, rate of return of spontaneous circulation, and prognosis were examined. Tracheal intubation was successful on the first attempt in 92% of cases. Rate of return of spontaneous circulation was high in paramedics whose post-training duration was short. No return of spontaneous circulation occurred after a second attempt. Four patients survived asphyxia or aspiration. It is important to perform successful tracheal intubation on the first attempt, to recognize the probability of successful resuscitation in patients with exogenous disease, and to strengthen the medical control system.

  4. Retrograde light-guided laryngoscopy for tracheal intubation: clinical practice and comparison with conventional direct laryngoscopy.

    PubMed

    Yang, Tao; Hou, Jiong; Li, Jinbao; Zhang, Xu; Zhu, Xiaoyan; Ni, Wen; Mao, Yanfei; Deng, Xiaoming

    2013-05-01

    Tracheal intubation with conventional laryngoscopy requires many trials until beginners are sufficiently skilled in intubating patients safely. To facilitate intubation, the authors used retrograde light-guided laryngoscopy (RLGL) and compared its feasibility with conventional direct laryngoscopy (DL). Twenty operators participated in a prospective, randomized, open-label, parallel-arm study. These operators intubated 205 patients randomly according to a computer-generated procedure by using either DL or RLGL (five intubations with each technique). The primary outcome was the success rate of tracheal intubation. The authors evaluated the success rate of tracheal intubation, the time to glottic exposure and tracheal intubation, and the Cormack and Lehane grades. Compared with DL, the success rate was greater in the RLGL group for all five intubations (72% vs. 47%; rate difference, 25%; 95% CI [11.84-38.16%], P < 0.001). This was associated with a shorter time to glottic exposure (median [25th and 75th percentile]; 27 [15; 42] vs. 45 [30; 73] s, P < 0.001), shorter intubation time (66 [44; 120] vs. 120 [69; 120] s, P < 0.001), and decreased throat soreness (mean ± SD; visual analog scale, 2.1 ± 0.9 vs. 3.7 ± 1.0 cm, P = 0.001) in the RLGL group compared to the DL group. RLGL is an alternative intubation technique. In our study, it enables beginners to intubate patients more successfully and quickly than conventional DL.

  5. Tracheal intubation by novice staff: the direct vision laryngoscope or the lighted stylet (Trachlight)?

    PubMed Central

    Soh, C; Kong, C; Kong, C; Ip-Yam, P; Chin, E; Goh, M

    2002-01-01

    Objective: To compare the ease of use of the direct vision laryngoscope and the lighted stylet (Trachlight) by novice staff. Methods: Ten novice medical officers (MOs) performed orotracheal intubations using either the conventional direct vision laryngoscope (DL) or a lighted stylet device (Trachlight). They performed their DL intubations during the first phase of the study, followed by the Trachlight intubations in the subsequent phase. Results: 51 of 54 (94%) of the DL intubation attempts were successful compared with 36 of 54 (67%) of the Trachlight intubations (p<0.001). The mean (SEM) time for intubation was 44 (7) seconds in the DL group and 66 (13) seconds in the Trachlight group (p=0.004). In addition 45 of 54 (83%) of the DL intubations were successful at the first attempt versus 15 of 54 (28%) in the Trachlight group (p<0.001). Conclusion: The results show that the use of the conventional direct vision laryngoscope in novices is associated with significantly shorter mean intubation times and higher success rates on the first attempt compared with the Trachlight. PMID:12101133

  6. A systematic review and meta-regression analysis of mivacurium for tracheal intubation.

    PubMed

    Vanlinthout, L E H; Mesfin, S H; Hens, N; Vanacker, B F; Robertson, E N; Booij, L H D J

    2014-12-01

    We systematically reviewed factors associated with intubation conditions in randomised controlled trials of mivacurium, using random-effects meta-regression analysis. We included 29 studies of 1050 healthy participants. Four factors explained 72.9% of the variation in the probability of excellent intubation conditions: mivacurium dose, 24.4%; opioid use, 29.9%; time to intubation and age together, 18.6%. The odds ratio (95% CI) for excellent intubation was 3.14 (1.65-5.73) for doubling the mivacurium dose, 5.99 (2.14-15.18) for adding opioids to the intubation sequence, and 6.55 (6.01-7.74) for increasing the delay between mivacurium injection and airway insertion from 1 to 2 min in subjects aged 25 years and 2.17 (2.01-2.69) for subjects aged 70 years, p < 0.001 for all. We conclude that good conditions for tracheal intubation are more likely by delaying laryngoscopy after injecting a higher dose of mivacurium with an opioid, particularly in older people. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  7. Fibre-optic awake intubation for caesarean section in a parturient with predicted difficult airway.

    PubMed

    Trevisan, P

    2002-10-01

    Anaesthetic management of a parturient with predicted difficult airway presenting for caesarean section (CS) is not a straightforward decision: general anaesthesia should be avoided because intubation can be impossible and a "cannot intubate, cannot ventilate" scenario might ensue, on the other hand regional techniques can be unsuccessful or, though rarely, have complications that require emergency intubation. The case is presented of a primigravida admitted to hospital at 37 weeks' gestation with hypertension, intrauterine growth retardation and oligohydramnios. After a few days' observation, it was decided to proceed with an elective CS. The preoperative airway examination revealed a poor mouth opening with an interdental distance of 20 mm and a Mallampati class IV. The patient was classified as a case of difficult intubation and the following anaesthetic options were considered: epidural anaesthesia, spinal anaesthesia and awake fibreoptic intubation followed by general anaesthesia. The pros and the cons of these techniques were explained to the patient and it was suggested that awake fibreoptic intubation was the safest option. The patient gave her consent, so an uneventful nasal awake fibreoptic intubation was carried out under local anaesthesia. This case report offers the opportunity to underline the risk to perform a central blockade in a parturient with predicted difficult intubation, arguing that the safest course of action is an awake fibrescopic intubation, besides some controversial points to safely perform awake fibreoptic intubation in obstetric patients are discussed.

  8. Pre-Hospital Intubation Factors and Pneumonia in Trauma Patients

    PubMed Central

    Warner, Keir; Bulger, Eileen M.; Sharar, Sam R.; Maier, Ronald V.; Cuschieri, Joseph

    2011-01-01

    Abstract Background We reported similar rates of ventilator-associated pneumonia (VAP) previously in trauma patients intubated either in a pre-hospital (PH) venue or the emergency department. A subset of PH intubations with continuous quality assessment was re-examined to identify the intubation factors associated with VAP. Methods The subgroup was derived from an existing data set of consecutive adult trauma patients intubated prior to Level I trauma center admission July 2007–July 2008. Intubation details recorded included bag-valve mask ventilation (BVM) and the presence of material in the airway. The diagnosis of VAP was made preferentially by quantitative bronchoalveolar lavage (BAL) cultures (≥104 colony-forming units indicating infection). Baseline data, injury characteristics, and circumstances of intubation of patients with and without VAP were compared by univariable analysis. Results Detailed data were available for 197 patients; 32 (16.2%) developed VAP, on average 6.0±0.7 days after admission. Baseline characteristics were similar in the groups, but diabetes mellitus was more common in the VAP group (4 [12.5%] vs. 5 [3.0%]; p=0.02). There was a higher rate of blunt injury in the VAP patients (28 [87.5%] vs. 106 [64.2%]; p=0.01) and higher injury severity scores (33.1±2.8 vs. 23.0±1.0; p=0.0002) and chest Abbreviated Injury Scores (2.6±0.3 vs. 1.5±0.1; p=0.002). Lower Glasgow Coma Scale scores (7.9±0.9 vs. 9.9±0.4; p=0.04) and greater use of BVM (18 [56.3%] vs. 56 [34.0%]; p=0.02) were observed in patients who developed VAP. Among aspirations, 10 (31.3%) of patients with emesis developed VAP compared with only 4 (12.5%) with blood in the airway (p=0.003). Conclusion Aspiration, along with depressed consciousness and greater injury severity, may predispose trauma patients to VAP. Prospective studies should focus on the quality and timing of aspiration relative to intubation to determine if novel interventions can prevent aspiration or decrease

  9. Pre-hospital intubation factors and pneumonia in trauma patients.

    PubMed

    Evans, Heather L; Warner, Keir; Bulger, Eileen M; Sharar, Sam R; Maier, Ronald V; Cuschieri, Joseph

    2011-10-01

    We reported similar rates of ventilator-associated pneumonia (VAP) previously in trauma patients intubated either in a pre-hospital (PH) venue or the emergency department. A subset of PH intubations with continuous quality assessment was re-examined to identify the intubation factors associated with VAP. The subgroup was derived from an existing data set of consecutive adult trauma patients intubated prior to Level I trauma center admission July 2007-July 2008. Intubation details recorded included bag-valve mask ventilation (BVM) and the presence of material in the airway. The diagnosis of VAP was made preferentially by quantitative bronchoalveolar lavage (BAL) cultures (≥ 10⁴ colony-forming units indicating infection). Baseline data, injury characteristics, and circumstances of intubation of patients with and without VAP were compared by univariable analysis. Detailed data were available for 197 patients; 32 (16.2%) developed VAP, on average 6.0±0.7 days after admission. Baseline characteristics were similar in the groups, but diabetes mellitus was more common in the VAP group (4 [12.5%] vs. 5 [3.0%]; p=0.02). There was a higher rate of blunt injury in the VAP patients (28 [87.5%] vs. 106 [64.2%]; p=0.01) and higher injury severity scores (33.1±2.8 vs. 23.0±1.0; p=0.0002) and chest Abbreviated Injury Scores (2.6±0.3 vs. 1.5±0.1; p=0.002). Lower Glasgow Coma Scale scores (7.9±0.9 vs. 9.9±0.4; p=0.04) and greater use of BVM (18 [56.3%] vs. 56 [34.0%]; p=0.02) were observed in patients who developed VAP. Among aspirations, 10 (31.3%) of patients with emesis developed VAP compared with only 4 (12.5%) with blood in the airway (p=0.003). Aspiration, along with depressed consciousness and greater injury severity, may predispose trauma patients to VAP. Prospective studies should focus on the quality and timing of aspiration relative to intubation to determine if novel interventions can prevent aspiration or decrease the risk of VAP after aspiration.

  10. Lightweight Valve Closes Duct Quickly

    NASA Technical Reports Server (NTRS)

    Fournier, Walter L.; Burgy, N. Frank

    1991-01-01

    Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

  11. Interventions to Improve Patient Safety During Intubation in the Neonatal Intensive Care Unit

    PubMed Central

    Grubb, Peter H.; Lea, Amanda S.; Walsh, William F.; Markham, Melinda H.; Maynord, Patrick O.; Whitney, Gina M.; Stark, Ann R.; Ely, E. Wesley

    2016-01-01

    OBJECTIVE: To improve patient safety in our NICU by decreasing the incidence of intubation-associated adverse events (AEs). METHODS: We sequentially implemented and tested 3 interventions: standardized checklist for intubation, premedication algorithm, and computerized provider order entry set for intubation. We compared baseline data collected over 10 months (period 1) with data collected over a 10-month intervention and sustainment period (period 2). Outcomes were the percentage of intubations containing any prospectively defined AE and intubations with bradycardia or hypoxemia. We followed process measures for each intervention. We used risk ratios (RRs) and statistical process control methods in a times series design to assess differences between the 2 periods. RESULTS: AEs occurred in 126/273 (46%) intubations during period 1 and 85/236 (36%) intubations during period 2 (RR = 0.78; 95% confidence interval [CI], 0.63–0.97). Significantly fewer intubations with bradycardia (24.2% vs 9.3%, RR = 0.39; 95% CI, 0.25–0.61) and hypoxemia (44.3% vs 33.1%, RR = 0.75, 95% CI 0.6–0.93) occurred during period 2. Using statistical process control methods, we identified 2 cases of special cause variation with a sustained decrease in AEs and bradycardia after implementation of our checklist. All process measures increased reflecting sustained improvement throughout data collection. CONCLUSIONS: Our interventions resulted in a 10% absolute reduction in AEs that was sustained. Implementation of a standardized checklist for intubation made the greatest impact, with reductions in both AEs and bradycardia. PMID:27694281

  12. Does systemic lidocaine reduce ketamine requirements for endotracheal intubation in calves?

    PubMed

    Lauper, Josiane; Marolf, Vincent; Levionnois, Olivier; Schelling, Esther; Meylan, Mireille; Spadavecchia, Claudia

    2017-03-01

    To investigate whether an intravenous (IV) lidocaine bolus in calves premedicated with xylazine-butorphanol reduces the amount of ketamine required to allow endotracheal intubation. Randomized, prospective clinical study. In total, 41 calves scheduled for elective umbilical surgery. Calves were randomly assigned to one of two groups (L: lidocaine or S: saline). The calves were administered xylazine (0.07 mg kg -1 ) and butorphanol (0.1 mg kg -1 ) intramuscularly and 10 minutes later lidocaine (2 mg kg -1 ; group L) or saline (group S) IV over 1 minute. After 2 minutes, ketamine (2.5 mg kg -1 ) was injected IV. If the depth of anaesthesia was insufficient for intubation, additional ketamine (1 mg kg -1 ) was administered every minute until intubation was successful. The amount of ketamine required for intubation, respiratory rate, pulse rate, arterial pressures, the depth of sedation and conditions of endotracheal intubation after induction of anaesthesia were compared between the two groups. The calves in group L were sedated more deeply than those in group S; however, neither the median (range) amount of ketamine required for intubation, 3.5 (2.5-4.5) mg kg -1 and 3.5 (2.5-3.5) mg kg -1 , respectively, nor the induction quality differed significantly between the groups. A bolus of lidocaine (2 mg kg -1 ) administered 10 minutes after xylazine-butorphanol in calves deepened the degree of sedation but did not decrease the requirement of ketamine for endotracheal intubation. No adverse effects were recorded in the physiological variables measured. Copyright © 2017. Published by Elsevier Ltd.

  13. Just-in-Time Video Laryngoscopy Versus Direct Laryngoscopy for Neonatal Intubation.

    PubMed

    Grgurich, Erin; Arnemann, Cynthia; Amon, Kim; Horton, Rose; Carlson, Jestin N

    As neonatal endotracheal intubation (ETI) is a low-frequency, high-consequence event, it is essential that providers have access to resources to aid in ETI. We sought to determine the impact of video laryngoscopy (VL) with just-in-time training on intubation outcomes over direct laryngoscopy (DL) when performed by neonatal nurses. We conducted a prospective, randomized, crossover study with neonatal nurses employed at a level 2 neonatal intensive care unit (NICU). Nurses performed both DL and VL on a neonatal mannequin using a CMAC (Karl Storz Corp, Tuttlingen, Germany) either with the assistance of the screen (VL) or without (DL). Before performing the intubation, providers were given a just-in-time, brief education presentation and allowed to practice with the device. Each ETI attempt was reviewed to obtain the percentage of glottic opening (POGO) score, time to intubation (TTI, time from insertion of the blade into the mouth until the first breath was delivered), and time from blade insertion until the best POGO score. We enrolled 19 participants, with a median (interquartile range) of 20 (9-26) years of experience and having a median of 2 (1-3) intubations within the past year. None had used VL in the NICU previously. Median TTI did not differ between DL and VL: 19.9 (15.3-41.5) vs 20.3 (17.9-24.4) (P = 1). POGO scores and the number of attempts also did not differ between DL and VL. In our simulated setting, just-in-time VL training provided similar intubation outcomes compared with DL in ETI performed by neonatal nurses. Just-in-time VL education may be an alternative to traditional DL for neonatal intubations.

  14. The effects of succinylcholine or low-dose rocuronium to aid endotracheal intubation of adult sows

    PubMed Central

    Duke-Novakovski, Tanya; Ambros, Barbara; Auckland, Crissie D.; Harding, John C.S.

    2012-01-01

    This randomized, prospective, blinded study compared the use of succinylcholine or rocuronium to aid endotracheal intubation of 27 adult sows [mean body weight 261 ± 28 (standard deviation) kg]. Preliminary trials allowed development of the intubation technique and skills. The sows were premedicated with azaperone, atropine, and morphine, and anesthesia was induced with thiopental [6 mg/kg body weight (BW)]. Nine sows each received succinylcholine (1.0 mg/kg BW), rocuronium (0.5 mg/kg BW), or saline (15 mL) after induction. Increments of thiopental (1 mg/kg BW) were used if swallowing impaired intubation. Intubation was performed 45 s after injection of the test drug and was timed and scored. The intubation scores were analyzed with Kruskal-Wallis analysis of variance (ANOVA). Time taken for intubation, body weight, and total dose of thiopental were analyzed with ANOVA and Bonferroni’s multiple-comparisons test. No significant differences (at P < 0.05) were found between the groups with regard to intubation score, time taken for intubation, or total thiopental dose. Thus, neuromuscular blocking agents did not aid endotracheal intubation of adult sows anesthetized with thiopental. PMID:22754096

  15. Telemedicine-Assisted Intubation in Rural Emergency Departments: A National Emergency Airway Registry Study.

    PubMed

    Van Oeveren, Lucas; Donner, Julie; Fantegrossi, Andrea; Mohr, Nicholas M; Brown, Calvin A

    2017-04-01

    Intubation in rural emergency departments (EDs) is a high-risk procedure, often with little or no specialty support. Rural EDs are utilizing real-time telemedicine links, connecting providers to an ED physician who may provide clinical guidance. We endeavored to describe telemedicine-assisted intubation in rural EDs that are served by an ED telemedicine network. Prospective data were collected on all patients who had an intubation attempt while on the video telemedicine link from May 1, 2014 to April 30, 2015. We report demographic information, indication, methods, number of attempts, operator characteristics, telemedicine involvement/intervention, adverse events, and clinical outcome by using descriptive statistics. Included were 206 intubations. The most common indication for intubation was respiratory failure. First-pass success rate (postactivation) was 71%, and 96% were eventually intubated. Most attempts (66%) used rapid-sequence intubation. Fifty-four percent of first attempts used video laryngoscopy (VL). Telemedicine providers intervened in 24%, 43%, and 55% of first-third attempts, respectively. First-pass success with VL and direct laryngoscopy was equivalent (70% vs. 71%, p = 0.802). Adverse events were reported in 49 cases (24%), which were most frequently hypoxemia. The impact of telemedicine during emergency intubation is not defined. We showed a 71% first-pass rate post-telemedicine linkage (70% of cases had a previous attempt). Our ultimate success rate was 96%, similar to that in large-center studies. Telemedicine support may contribute to success. Telemedicine-supported endotracheal intubation performed in rural hospitals is feasible, with good success rates. Future research is required to better define the impact of telemedicine providers on emergency airway management.

  16. Non-intubated video-assisted thoracoscopic lung resections: the future of thoracic surgery?

    PubMed

    Gonzalez-Rivas, Diego; Bonome, Cesar; Fieira, Eva; Aymerich, Humberto; Fernandez, Ricardo; Delgado, Maria; Mendez, Lucia; de la Torre, Mercedes

    2016-03-01

    Thanks to the experience gained through the improvement of video-assisted thoracoscopic surgery (VATS) technique, and the enhancement of surgical instruments and high-definition cameras, most pulmonary resections can now be performed by minimally invasive surgery. The future of the thoracic surgery should be associated with a combination of surgical and anaesthetic evolution and improvements to reduce the trauma to the patient. Traditionally, intubated general anaesthesia with one-lung ventilation was considered necessary for thoracoscopic major pulmonary resections. However, thanks to the advances in minimally invasive techniques, the non-intubated thoracoscopic approach has been adapted even for use with major lung resections. An adequate analgesia obtained from regional anaesthesia techniques allows VATS to be performed in sedated patients and the potential adverse effects related to general anaesthesia and selective ventilation can be avoided. The non-intubated procedures try to minimize the adverse effects of tracheal intubation and general anaesthesia, such as intubation-related airway trauma, ventilation-induced lung injury, residual neuromuscular blockade, and postoperative nausea and vomiting. Anaesthesiologists should be acquainted with the procedure to be performed. Furthermore, patients may also benefit from the efficient contraction of the dependent hemidiaphragm and preserved hypoxic pulmonary vasoconstriction during surgically induced pneumothorax in spontaneous ventilation. However, the surgical team must be aware of the potential problems and have the judgement to convert regional anaesthesia to intubated general anaesthesia in enforced circumstances. The non-intubated anaesthesia combined with the uniportal approach represents another step forward in the minimally invasive strategies of treatment, and can be reliably offered in the near future to an increasing number of patients. Therefore, educating and training programmes in VATS with non-intubated

  17. Preflight versus en route success and complications of rapid sequence intubation in an air medical service.

    PubMed

    Slater, E A; Weiss, S J; Ernst, A A; Haynes, M

    1998-09-01

    Maintenance of an airway in the air medically transported patient is of paramount importance. The purpose of this study is to compare preflight versus en route rapid sequence intubation (RSI)-assisted intubations and to determine the value of air medical use of RSI. This study is a 31-month retrospective review of all patients intubated and transported by a large city air medical service. Subgroup analysis was based on whether patients were transported from a hospital or a scene and whether they were intubated preflight or en route. Information on age, Glasgow Coma Scale score, type of scene, ground time, and previous attempts at intubation was recorded. Complications included failures, multiple attempts at intubation, arrhythmias, and need for repeated paralytic agents. Comparisons were made using a confidence interval analysis. An alpha of 0.05 was considered significant; Bonferroni correction was used for multiple comparisons. Three hundred twenty-five patients were intubated and transported by Lifeflight during the study period. Two hundred eighty-eight patients were intubated using RSI (89%). The success rate was 97%. Preflight intubations were performed on 100 hospital calls and 86 scene calls. En route intubations were performed on 40 hospital cases and 62 scene calls. Patients who underwent preflight intubations were significantly younger than those who underwent en route intubations for both the hospital group (34 +/- 11 vs. 44 +/- 24 years, p < 0.05) and the scene group (27 +/- 13 vs. 32 +/- 16 years,p < 0.05). Otherwise, the demographic characteristics of the four groups were similar. Trauma accounted for 60 to 70% of hospital transfers and almost 95 to 100% of scene calls. Compared with preflight intubations, there was a significant decrease in ground time for hospital patients who were intubated en route (26 +/- 10 vs. 34 +/- 11 minutes, p < 0.05) and for scene patients who were intubated en route (11 +/- 8 vs. 18 +/- 9 minutes, p < 0.05). There were

  18. Comparison of glottic visualisation and ease of intubation with different laryngoscope blades.

    PubMed

    Kulkarni, Atul P; Tirmanwar, Amar S

    2013-03-01

    Literature suggests glottic view is better with straight blades while tracheal intubation is easier with curved blades. To compare glottic view and ease of intubation with Macintosh, Miller, McCoy blades and the Trueview(®) laryngoscope. This prospective randomised study was undertaken in operation theatres of a 550 bedded tertiary referral cancer centre after approval from the Institutional Review Board. We compared the Macintosh, Miller, McCoy blades and the Trueview(®) laryngoscope for glottic visualisation and ease of tracheal intubation; in 120 patients undergoing elective cancer surgery; randomly divided into four groups. After induction of anaesthesia laryngoscopy was performed and trachea intubated. We recorded: Visualisation of glottis (Cormack Lehane grade), ease of intubation, number of attempts; need to change the blade and need for external laryngeal manipulation. Demographic data, Mallampati classification were compared using the Chi-square test. A P<0.05 was considered significant. Grade 1 view was obtained most often (87% patients) with Trueview(®) laryngoscope. Intubation was easier (Grade 1) with Trueview(®) and McCoy blades (93% each). Seven patients needed two attempts; one patient in Miller group needed three attempts. No patient in McCoy and Trueview(®) Groups required external laryngeal manipulation. We found that in patients with normal airway glottis was best visualised with Miller blade and Trueview(®) laryngoscope however, the trachea was more easily intubated with McCoy and Macintosh blades and Trueview(®) laryngoscope.

  19. Patent vitellointestinal duct

    PubMed Central

    Agrawal, Sanwar; Memon, Ameen

    2010-01-01

    During the 3rd week of intrauterine life there is a communication between the intraembryonic gut and the yolk sac. As the development proceeds this communication narrows into a tube known as the vitellointestinal duct (VID). With the establishment of placental nutrition this duct usually becomes obliterated by the end of the 7th week of intrauterine life. In about 2% of humans this duct persists and gives rise to a group of anomalies of which Meckel's diverticulum is the commonest and complete patency of the duct is the rarest.1 We report a case of a 4-month-old infant who presented with umbilical polyp, discharge from the umbilicus, significant dehydration and failure to thrive because of complete patency of the VID PMID:22778111

  20. Intubated Trauma Patients Do Not Require Full Trauma Team Activation when Effectively Triaged.

    PubMed

    Harbrecht, Brian G; Franklin, Glen A; Smith, Jason W; Benns, Matthew V; Miller, Keith R; Nash, Nicholas A; Bozeman, Matthew C; Coleman, Royce; O'Brien, Dan; Richardson, J David

    2016-04-01

    Full trauma team activation in evaluating injured patients is based on triage criteria and associated with significant costs and resources that should be focused on patients who truly need them. Overtriage leads to inefficient care, particularly when resources are finite, and it diverts care from other vital areas. Although shock and gunshot wounds to the abdomen are accepted indicators for full trauma activation, intubation as the sole criterion is controversial. We evaluated our experience to assess if intubation alone merited the highest level of trauma activation. All trauma patients from 2012 to 2013 were assessed for level of activation, injury characteristics, presence of intubation, and outcomes. Of 5,881 patients, 646 (11%) were level 1 (full) and 2,823 (48%) were level 2 (partial) activations. Level 1 patients were younger (40 ± 17 vs 45 ± 20 years), had more penetrating injuries (42% vs 9%), and had higher mortality (26% vs 8%)(p < 0.001). Intubated level 2 patients (n = 513), compared with intubated level 1 patients (n = 320), had higher systolic blood pressure (133 ± 44 vs 90 ± 58 mmHg), lower Injury Severity Score (21 ± 13 vs 25 ± 16), more falls (25% vs 3%), fewer penetrating injuries (11% vs 23%), and lower mortality (31% vs 48%)(p < 0.01). Fewer intubated level patients went directly to the operating room from the emergency department (ED)(16% vs 33%), and most who did had a craniotomy (63% vs 13%). Only 3% of intubated level 2 patients underwent laparotomy compared with 20% of intubated level 1 patients (p < 0.001). The ED lengths of stay before obtaining a head CT (47 ± 26 vs 48 ± 31 minutes) and craniotomy (109 ± 61 vs 102 ± 46 minutes) were similar. Deaths in intubated level 2 patients were primarily from fatal brain injuries. When appropriately triaged, selected intubated trauma patients do not require full trauma activation to receive timely, efficient care. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc

  1. Factors Associated with First-Pass Success in Pediatric Intubation in the Emergency Department.

    PubMed

    Goto, Tadahiro; Gibo, Koichiro; Hagiwara, Yusuke; Okubo, Masashi; Brown, David F M; Brown, Calvin A; Hasegawa, Kohei

    2016-03-01

    The objective of this study was to investigate the factors associated with first-pass success in pediatric intubation in the emergency department (ED). We analyzed the data from two multicenter prospective studies of ED intubation in 17 EDs between April 2010 and September 2014. The studies prospectively measured patient's age, sex, principal indication for intubation, methods (e.g., rapid sequence intubation [RSI]), devices, and intubator's level of training and specialty. To evaluate independent predictors of first-pass success, we fit logistic regression model with generalized estimating equations. In the sensitivity analysis, we repeated the analysis in children <10 years. A total of 293 children aged ≤18 years who underwent ED intubation were eligible for the analysis. The overall first-pass success rate was 60% (95%CI [54%-66%]). In the multivariable model, age ≥10 years (adjusted odds ratio [aOR], 2.45; 95% CI [1.23-4.87]), use of RSI (aOR, 2.17; 95% CI [1.31-3.57]), and intubation attempt by an emergency physician (aOR, 3.21; 95% CI [1.78-5.83]) were significantly associated with a higher chance of first-pass success. Likewise, in the sensitivity analysis, the use of RSI (aOR, 3.05; 95% CI [1.63-5.70]), and intubation attempt by an emergency physician (aOR, 4.08; 95% CI [1.92-8.63]) were significantly associated with a higher chance of first-pass success. Based on two large multicenter prospective studies of ED airway management, we found that older age, use of RSI, and intubation by emergency physicians were the independent predictors of a higher chance of first-pass success in children. Our findings should facilitate investigations to develop optimal airway management strategies in critically-ill children in the ED.

  2. Magnesium sulphate: an adjuvant to tracheal intubation without muscle relaxation--a randomised study.

    PubMed

    Aissaoui, Younes; Qamous, Youssef; Serghini, Issam; Zoubir, Mohammed; Salim, Jaafar Lalaoui; Boughalem, Mohammed

    2012-08-01

    Tracheal intubation without administration of a neuromuscular blocking drug is used frequently in anaesthesia. Several techniques and adjuvants have been tried to improve intubating conditions. Magnesium sulphate is an agent with analgesic, anaesthetic and muscle relaxant effects. To assess the effect of magnesium sulphate on intubating conditions after induction of anaesthesia without a neuromuscular blocking drug. Double-blinded randomised study. Sixty patients with American Society of Anesthesiologists physical status 1/2 scheduled for elective surgery under general anaesthesia were included. Avicenna Military Hospital between June 2010 and March 2011. Before induction of general anaesthesia, patients were assigned to receive either a 10-min infusion of magnesium sulphate 45 mg kg(-1) in 100 ml of isotonic saline (magnesium group, n = 30) or the same volume of saline (control group, n = 30). Anaesthesia was induced with fentanyl 3 μg kg(-1) followed 3 min later by propofol 2.5 mg kg(-1). Intubating conditions were evaluated by a blinded anaesthesiologist using the criteria of the Copenhagen consensus conference: ease of laryngoscopy, vocal cord position and/or movement and response to intubation or cuff inflation (cough or diaphragmatic movement). Intubating conditions were considered as acceptable (excellent or good) or unacceptable (poor). Mean arterial pressure and heart rate were also recorded during the study period. The two groups were comparable in their demographic profiles. Clinically acceptable intubating conditions were observed more frequently in the magnesium group than in the control group: 25 (83%) vs. 18 patients (60%) (P = 0.042). There was no failed intubation. There were no differences between the groups with regard to haemodynamic variables. Addition of magnesium sulphate to propofol and fentanyl at induction of anaesthesia significantly improved intubating conditions without administration of a neuromuscular blocking drug.

  3. Duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma.

    PubMed

    Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin

    2013-04-21

    At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.

  4. A comparative study of effect of sevoflurane on intubating conditions with rocuronium in neurosurgical patients.

    PubMed

    Mitra, Saikat; Purohit, Shobha; Bhatia, Sonali; Kalra, Poonam; Sharma, Satya Prakash

    2015-12-01

    Rocuronium may not always be the preferred relaxant for rapid sequence intubation. When 2% sevoflurane is used in conjunction with rocuronium, it may reduce the time required for achieving complete skeletal muscle relaxation with the intubating dose of rocuronium. This study was prospective, randomised, double-blind in nature and compared the effect of sevoflurane on intubation time and intubating conditions when used along with rocuronium. Thirty adult patients belonging to American Society of Anesthesiologists physical status Grades 1 and 2, of either gender aged between 30 and 65 years undergoing neurosurgical operations were randomly allocated into two equal groups: Group R received 0.8 mg/kg rocuronium, and Group RS received 0.8 mg/kg of rocuronium with 2% sevoflurane. Onset time of intubation was assessed using train-of-four stimuli. The intubating conditions were compared using the Cooper scoring system and the haemodynamic responses were compared between the two groups. The onset time of intubation was 101.73 ± 10.28 s in Group R and 60.4 ± 4.1 s in Group RS (P < 0.001), with excellent intubating conditions in both groups and without any adverse effects. Significant differences in heart rate and mean arterial pressure were seen immediately after intubation, at 1 and 3 min (P < 0.05) between the two groups. Rocuronium 0.8 mg/kg along with 2% sevoflurane provides excellent intubating conditions within 60-66 s from its administration.

  5. Atraumatic intubation: experience using a 5.0 endotracheal tube without a stylet for laryngeal surgery.

    PubMed

    Moore, Jaime E; Hu, Amanda; Rutt, Amy; Green, Parmis; Hawkshaw, Mary; Sataloff, Robert T

    2015-02-01

    Vocal fold injury is a well-know complication of intubation, with rates reported as high as 69%. Laryngology textbooks recommend the use of a small endotracheal tube (ETT) to help avoid these complications and optimize visualization. Case reports have suggested that the rigid stylet can lead to laryngeal injury. Given the additional risks, intubation without the stylet is our preferred practice. There is limited documentation in the literature regarding this viewpoint. Our study investigated the feasibility of and potential barriers to intubation using 5.0 ETT without a stylet. Prospective study. Consecutive adult patients undergoing laryngeal surgery were recruited for intubation with a 5.0 ETT without a stylet. Demographic data, specialty and training level of the intubator, and factors that would predict a difficult intubation were recorded. Descriptive statistical analysis was performed. Findings of the participants (n = 67) included average American Society of Anesthesiologists (ASA) physical status classification (2.2), average Mallampati score (1.7), average Cormack-Lehane grade (1.5), and average body mass index (28.0). Five patients (7.4%) required intubation using a stylet, and one of these five participants was intubated initially with a stylet. Of these five participants, 80% required use of a GlideScope (P < .001), and they had significantly higher ASA classification (P = .047) and number of intubation attempts (P = .042). One patient sustained an oropharyngeal injury during intubation with a stylet. No participants had laryngeal injury. Most patients can be intubated successfully using a 5.0 ETT without a stylet. There were no cases of laryngeal trauma with this technique. 2b. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Intubation simulation with a cross-sectional visual guidance.

    PubMed

    Rhee, Chi-Hyoung; Kang, Chul Won; Lee, Chang Ha

    2013-01-01

    We present an intubation simulation with deformable objects and a cross-sectional visual guidance using a general haptic device. Our method deforms the tube model when it collides with the human model. Mass-Spring model with the Euler integration is used for the tube deformation. For the trainee's more effective understanding of the intubation process, we provide a cross-sectional view of the oral cavity and the tube. Our system also applies a stereoscopic rendering to improve the depth perception and the reality of the simulation.

  7. Radiopaque biodegradable stent for duct-to-duct biliary reconstruction in pigs.

    PubMed

    Tanimoto, Yoshisato; Tashiro, Hirotaka; Mikuriya, Yoshihiro; Kuroda, Shintaro; Hashimoto, Masakazu; Kobayashi, Tsuyoshi; Taniura, Tokunori; Ohdan, Hideki

    2016-06-01

    Biliary stricture is a common cause of morbidity after liver transplantation. We previously developed a duct-to-duct biliary anastomosis technique using a biodegradable stent tube and confirmed the feasibility and safety of biliary stent use. However, the duration and mechanism of biliary stent absorption in the common bile duct remain unclear. Radiopaque biodegradable biliary stents were created using a copolymer of L-lactide and ε-caprolactone (70: 30) and coated with barium sulfate. Stents were surgically implanted in the common bile duct of 11 pigs. Liver function tests and computed tomography (CT) scans were performed postoperatively, and autopsies were conducted 6 months after biliary stent implantation. After the surgery, all 11 pigs had normal liver function and survived without any significant complications such as biliary leakage. A CT scan at 2 months post-procedure showed that the biliary stents were located in the hilum of the liver. The stents were not visible by CT scan at the 6-month follow-up examination. The surgical implantation of radiopaque biodegradable biliary stents in biliary surgery represents a new option for duct-to-duct biliary reconstruction. This technique appears to be feasible and safe and is not associated with any significant biliary complications. The advantage of coated biliary stent use is that it may be visualized using abdominal radiography such as CT.

  8. Reciprocity principle in duct acoustics

    NASA Technical Reports Server (NTRS)

    Cho, Y.-C.

    1979-01-01

    Various reciprocity relations in duct acoustics have been derived on the basis of the spatial reciprocity principle implied in Green's functions for linear waves. The derivation includes the reciprocity relations between mode conversion coefficients for reflection and transmission in nonuniform ducts, and the relation between the radiation of a mode from an arbitrarily terminated duct and the absorption of an externally incident plane wave by the duct. Such relations are well defined as long as the systems remain linear, regardless of acoustic properties of duct nonuniformities which cause the mode conversions.

  9. Critical Analyses and Development of Training Mechanisms: Cholinergic Crisis and Pediatric/Neonatal Intubation

    DTIC Science & Technology

    2015-02-01

    Anaesthesia, 1989. 36(2): p. 141-144. 8. Hall, R., et al., Human Patient Simulation Is Effective for Teaching Paramedic Students Endotracheal Intubation...duration and # of attempts, checklist and GRS scores [5]Calderwood -Medical students -Anesthetized cats -Success -PM [6]Falck -449 intubation...optic intubation – realism and effectiveness -Pig -Mannequin -Secretions -Anatomy -Appearance Technique - [8]Hall -36 paramedic students

  10. Endotracheal intubation: application of virtual reality to emergency medical services education.

    PubMed

    Mayrose, James; Myers, Jeffrey W

    2007-01-01

    Virtual reality simulation has been identified as an emerging educational tool with significant potential to enhance teaching of residents and students in emergency clinical encounters and procedures. Endotracheal intubation represents a critical procedure for emergency care providers. Current methods of training include working with cadavers and mannequins, which have limitations in their representation of reality, ethical concerns, and overall availability with access, cost, and location of models. This paper will present a human airway simulation model designed for tracheal intubation and discuss the aspects that lend itself to use as an educational tool. This realistic and dynamic model is used to teach routine intubations, while future models will include more difficult airway management scenarios. This work provides a solid foundation for future versions of the intubation simulator, which will incorporate two haptic devices to allow for simultaneous control of the laryngoscope blade and endotracheal tube.

  11. Bile duct hamartomas (von Mayenburg complexes) mimicking liver metastases from bile duct cancer: MRC findings

    PubMed Central

    Nagano, Yasuhiko; Matsuo, Kenichi; Gorai, Katsuya; Sugimori, Kazuya; Kunisaki, Chikara; Ike, Hideyuki; Tanaka, Katsuaki; Imada, Toshio; Shimada, Hiroshi

    2006-01-01

    We present a case of a 72-year-old man with a common bile duct cancer, who was initially believed to have multiple liver metastases based on computed tomography findings, and in whom magnetic resonance cholangiography (MRC) revealed a diagnosis of bile duct hamartomas. At exploration for pancreaticoduodenectomy, liver palpation revealed disseminated nodules at the surface of the liver. These nodules showed gray-white nodular lesions of about 0.5 cm in diameter scattered on the surface of both liver lobes, which were looked like multiple liver metastases from bile duct cancer. Frozen section of the liver biopsy disclosed multiple bile ducts with slightly dilated lumens embedded in the collagenous stroma characteristics of multiple bile duct hamartomas (BDHs). Only two reports have described the MRC features of bile duct hamartomas. Of all imaging procedures, MRC provides the most relevant features for the imaging diagnosis of bile duct hamartomas. PMID:16534895

  12. Bile Duct Cancer

    MedlinePlus

    ... the liver get rid of toxins and wastes. Bile duct cancer is rare. It can happen in the parts ... Itchy skin Fever Abdominal pain Tests to diagnose bile duct cancer may include a physical exam, imaging tests of ...

  13. Reference values of MRI measurements of the common bile duct and pancreatic duct in children.

    PubMed

    Gwal, Kriti; Bedoya, Maria A; Patel, Neal; Rambhatla, Siri J; Darge, Kassa; Sreedharan, Ram R; Anupindi, Sudha A

    2015-07-01

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and

  14. Transoral tracheal intubation of rodents using a fiberoptic laryngoscope.

    PubMed

    Costa, D L; Lehmann, J R; Harold, W M; Drew, R T

    1986-06-01

    A fiberoptic laryngoscope which allows direct visualization of the deep pharynx and epiglottis has been developed for transoral tracheal intubation of small laboratory mammals. The device has been employed in the intubation and instillation of a variety of substances into the lungs of rats, and with minor modification, has had similar application in mice, hamsters, and guinea pigs. The simplicity and ease of handling of the laryngoscope permits one person to intubate large numbers of enflurane anesthetized animals either on an open counter top or in a glove-box, as may be required for administration of carcinogenic materials. Instillation of 7Be-labeled carbon particles into the lungs of mice, hamsters, rats, and guinea pigs resulted in reasonably consistent interlobal distribution of particles for each test animal species with minimal tracheal deposition. However, actual lung tissue doses of carbon exhibited some species dependence.

  15. Air-Q intubating laryngeal airway: A study of the second generation supraglottic airway device.

    PubMed

    Attarde, Viren Bhaskar; Kotekar, Nalini; Shetty, Sarika M

    2016-05-01

    Air-Q intubating laryngeal mask airway (ILA) is used as a supraglottic airway device and as a conduit for endotracheal intubation. This study aims to assess the efficacy of the Air-Q ILA regarding ease of insertion, adequacy of ventilation, rate of successful intubation, haemodynamic response and airway morbidity. Sixty patients presenting for elective surgery at our Medical College Hospital were selected. Following adequate premedication, baseline vital parameters, pulse rate and blood pressure were recorded. Air-Q size 3.5 for patients 50-70 kg and size 4.5 for 70-100 kg was selected. After achieving adequate intubating conditions, Air-Q ILA was introduced. Confirming adequate ventilation, appropriate sized endotracheal tube was advanced through the Air-Q blindly to intubate the trachea. Placement of the endotracheal tube in trachea was confirmed. Air-Q ILA was successfully inserted in 88.3% of patients in first attempt and 11.7% patients in second attempt. Ventilation was adequate in 100% of patients. Intubation was successful in 76.7% of patients with Air-Q ILA. 23.3% of patients were intubated by direct laryngoscopy following failure with two attempts using Air-Q ILA. Post-intubation the change in heart rate was statistically significant (P < 0.0001). 10% of patients were noted to have a sore throat and 5% of patients had mild airway trauma. Air-Q ILA is a reliable device as a supraglottic airway ensuring adequate ventilation as well as a conduit for endotracheal intubation. It benefits the patient by avoiding the stress of direct laryngoscopy and is also superior alternative device for use in a difficult airway.

  16. [Selective left mainstem bronchial intubation in the neonatal intensive care unit].

    PubMed

    Ho, Anthony M H; Flavin, Michael P; Fleming, Melinda L; Mizubuti, Glenio Bitencourt

    Selective neonatal left mainstem bronchial intubation to treat right lung disease is typically achieved with elaborate maneuvers, instrumentation and devices. This is often attributed to bronchial geometry which favors right mainstem entry of an endotracheal tube deliberately advanced beyond the carina. A neonate with severe bullous emphysema affecting the right lung required urgent non-ventilation of that lung. We achieved left mainstem bronchial intubation by turning the endotracheal tube 180° such that the Murphy's eye faced the left instead of the right, and simulated a left-handed intubation by slightly orientating the endotracheal tube such that its concavity faced the left instead of the right as in a conventional right-handed intubation. Urgent intubation of the left mainstem bronchus with an endotracheal tube can be easily achieved by recognizing that it is the position of the endotracheal tube tip and the direction of its concavity that are the chief determinants of which bronchus an endotracheal tube goes when advanced. This is important in critically ill neonates as the margin of safety and time window are small, and the absence of double-lumen tubes. Use of fiberoptic bronchoscope and blockers should be reserved as backup plans. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  17. Bile duct stricture

    MedlinePlus

    ... duct, the tube that moves bile from the liver to the small intestine. Bile is a substance that helps with digestion. ... causes of this condition include: Cancer of the bile duct, liver or pancreas Damage and scarring due to a ...

  18. Prophylaxis against the systemic hypotension induced by propofol during rapid-sequence intubation.

    PubMed

    el-Beheiry, H; Kim, J; Milne, B; Seegobin, R

    1995-10-01

    The objective of this study was to determine the effectiveness of two prophylactic approaches against the anticipated hypotension induced by propofol during rapid-sequence intubation. Thirty-six male or female nonpremedicated ASA class I-II patients aged 21-60 yr undergoing elective outpatient surgery were included in the study. Patients were randomly allocated to receive pre-induction ephedrine sulphate (70 micrograms x kg(-1)iv), pre-induction volume loading (12 ml x kg(-1) Ringer's lactate) or no treatment. Rapid-sequence intubation with cricoid pressure was then performed with propofol (2.5 mg. x kg(-1)) and succinylcholine (1.5 mg x kg(-1). The lungs were subsequently ventilated with 0.25-0.5% isoflurane in a 2:1 N2O/O2 mixture. Vecuronium was given once neuromuscular function had recovered from the succinylcholine. Heart rate and systemic arterial blood pressure were measured non-invasively before induction, after propofol administration and every minute for ten minutes after intubation. Pre-induction volume loading prevented the hypotension observed before surgical stimulation in control and ephedrine groups. Moreover, pre-induction volume loading was not associated with increases in heart rate after intubation as was ephedrine administration. The intubating conditions were excellent to satisfactory in most patients and the overall incidence of adverse events during intubation was mainly due to pain during injection of propofol. The present study showed that preoperative volume loading is more efficacious than pre-induction administration of ephedrine sulphate in maintaining haemodynamic stability during rapid-sequence induction with propofol and succinylcholine. In addition, propofol in combination with succinylcholine provides excellent conditions for rapid-sequence intubation.

  19. Neuromuscular blocking agent administration for emergent tracheal intubation is associated with decreased prevalence of procedure-related complications.

    PubMed

    Wilcox, Susan R; Bittner, Edward A; Elmer, Jonathan; Seigel, Todd A; Nguyen, Nicole Thuy P; Dhillon, Anahat; Eikermann, Matthias; Schmidt, Ulrich

    2012-06-01

    Emergent intubation is associated with a high rate of complications. Neuromuscular blocking agents are routinely used in the operating room and emergency department to facilitate intubation. However, use of neuromuscular blocking agents during emergent airway management outside of the operating room and emergency department is controversial. We hypothesized that the use of neuromuscular blocking agents is associated with a decreased prevalence of hypoxemia and reduced rate of procedure-related complications. Five hundred sixty-six patients undergoing emergent intubations in two tertiary care centers, Massachusetts General Hospital, Boston, MA, and the University of California Los Angeles, Ronald Reagan Medical Center, Los Angeles, CA, were enrolled in a prospective, observational study. The 112 patients intubated during cardiopulmonary resuscitation were excluded, leaving 454 patients for analysis. All intubations were supervised by attendings trained in Critical Care Medicine. We measured intubating conditions, oxygen saturation during and 5 mins following intubation. We assessed the prevalence of procedure-related complications defined as esophageal intubation, traumatic intubation, aspiration, dental injury, and endobronchial intubation. The use of neuromuscular blocking agents was associated with a lower prevalence of hypoxemia (10.1% vs. 17.4%, p = .022) and a lower prevalence of procedure-related complications (3.1% vs. 8.3%, p = .012). This association persisted in a multivariate analysis, which controlled for airway grade, sedation, and institution. Use of neuromuscular blocking agents was associated with significantly improved intubating conditions (laryngeal view, p = .014; number of intubation attempts, p = .049). After controlling for the number of intubation attempts and laryngoscopic view, muscle relaxant use is an independent predictor of complications associated with emergency intubation (p = .037), and there is a trend towards improvement of

  20. Tracheal intubation in critically ill patients: a comprehensive systematic review of randomized trials.

    PubMed

    Cabrini, Luca; Landoni, Giovanni; Baiardo Radaelli, Martina; Saleh, Omar; Votta, Carmine D; Fominskiy, Evgeny; Putzu, Alessandro; Snak de Souza, Cézar Daniel; Antonelli, Massimo; Bellomo, Rinaldo; Pelosi, Paolo; Zangrillo, Alberto

    2018-01-20

    We performed a systematic review of randomized controlled studies evaluating any drug, technique or device aimed at improving the success rate or safety of tracheal intubation in the critically ill. We searched PubMed, BioMed Central, Embase and the Cochrane Central Register of Clinical Trials and references of retrieved articles. Finally, pertinent reviews were also scanned to detect further studies until May 2017. The following inclusion criteria were considered: tracheal intubation in adult critically ill patients; randomized controlled trial; study performed in Intensive Care Unit, Emergency Department or ordinary ward; and work published in the last 20 years. Exclusion criteria were pre-hospital or operating theatre settings and simulation-based studies. Two investigators selected studies for the final analysis. Extracted data included first author, publication year, characteristics of patients and clinical settings, intervention details, comparators and relevant outcomes. The risk of bias was assessed with the Cochrane Collaboration's Risk of Bias tool. We identified 22 trials on use of a pre-procedure check-list (1 study), pre-oxygenation or apneic oxygenation (6 studies), sedatives (3 studies), neuromuscular blocking agents (1 study), patient positioning (1 study), video laryngoscopy (9 studies), and post-intubation lung recruitment (1 study). Pre-oxygenation with non-invasive ventilation (NIV) and/or high-flow nasal cannula (HFNC) showed a possible beneficial role. Post-intubation recruitment improved oxygenation , while ramped position increased the number of intubation attempts and thiopental had negative hemodynamic effects. No effect was found for use of a checklist, apneic oxygenation (on oxygenation and hemodynamics), videolaryngoscopy (on number and length of intubation attempts), sedatives and neuromuscular blockers (on hemodynamics). Finally, videolaryngoscopy was associated with severe adverse effects in multiple trials. The limited available

  1. [Usefullness of bronchofiberscopy for difficult intubation in patients with severe motor and intellectual disabilities].

    PubMed

    Mizuno, Yuji; Ukaji, Koutarou

    2005-11-01

    In 21 patients with severe motor and intellectual disabilities, bronchofiberoptic intubation was performed because of difficulty in tracheal intubation by direct laryngoscopy. The patients ranged from 3 to 35 years old (mean age: 20.2 years). Twenty patients (95.2%) were bedridden. Among the 21 patients, 15 had cerebral palsy and 20 had hypertonia. The reason for intubation were acute respiratory failure due to pneumonia in 17 cases, suffocation after aspiration of food in 2 cases, hypovolemic shock in 1 case, and laryngotracheomalacia in 1 case. Intubation was done pernasally in 15 patients and perorally in 10. It was successful in 20 cases without any significant complications. The Cormack score ranged from 3rd degree in 4 cases to 4th in 17 cases. The 20 cases of successful fiberoptic intubation were divided into 7 patients with and 13 without tracheostomy. The mortality rate was 14.3% in patients with tracheostomy and 30.8% in those without tracheostomy. When more than 4 intubation trials were needed, there was a significantly higher mortality rate. In neurologically handicapped patients with deformity or hypertonia of the oral, cervical, or airway structures, a bronchofiberoptic procedure may be recommended when there is difficulty with intubation.

  2. Sealing ducts to save energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siuru, B.

    1996-07-01

    Large amounts of energy are wasted when heat leaks through ductwork located in uninsulated spaces. The Electric Power Research INstitute recently did a study that accurately measured these losses, then substantially reduced them by sealing the leaky ductwork. Six homes in the Pacific Northwest with significant duct leakage to the outside were selected for the study. The homes had electric resistance or heat pump, forced-air heating systems with a major portion of the supply and return ductwork in crawl spaces, attics, garages, etc. Measurements of duct leakage and heating system efficiency were done on all the homes before starting themore » duct sealing. Retrofitting included finding holes, gaps, cracks and disconnected joints in supply and return ducts as well as in plenums. When necessary, plenums were cut open for repairs. Leaks were sealed with Latex mastic and fiberglass tape. Outside ducts were covered or wrapped with insulation. Unducted returns were sealed with duct board. In some cases, leakage was corrected by merely reconnecting ducts and boots.« less

  3. Cost-effectiveness analysis of flexible optical scopes for tracheal intubation: a descriptive comparative study of reusable and single-use scopes.

    PubMed

    Gupta, Deepak; Wang, Hong

    2011-12-01

    To calculate the costs per intubation of reusable fiberoptic scopes versus single-use intubation scopes. Open-label retrospective study. University-affiliated hospital. The one-year intubation records of intubations performed with reusable intubation scopes, the one-year maintenance costs of these scopes, and their three-year repair cost records were analyzed. A total of 166 intubations were performed with reusable fiberoptic scopes in 2009. Calculations to assess the costs per intubation based on the documented records at our institution were made. The total cost of an intubation, the repair-to-intubation ratio, and the repair cost per intubation were determined. The total cost of an intubation at our institution in 2009, using reusable scopes, was $119.75 [US dollars (USD)], which included $20.15 (purchasing), $53.48 (repair), $33.16 (maintenance), and $12.96 (labor). The repair-to-intubation ratio was 1:55. Repair costs were $53.48 per intubation and $2,959.44 per instance of repair. The Ambu aScope, a single-use intubation scope, is a new addition to video laryngoscopy. The price should range within 10% of our intubation cost ($120.00 to $132.00 per single-use intubation scope). Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Prehospital rapid sequence intubation improves functional outcome for patients with severe traumatic brain injury: a randomized controlled trial.

    PubMed

    Bernard, Stephen A; Nguyen, Vina; Cameron, Peter; Masci, Kevin; Fitzgerald, Mark; Cooper, David J; Walker, Tony; Std, B Paramed; Myles, Paul; Murray, Lynne; David; Taylor; Smith, Karen; Patrick, Ian; Edington, John; Bacon, Andrew; Rosenfeld, Jeffrey V; Judson, Rodney

    2010-12-01

    To determine whether paramedic rapid sequence intubation in patients with severe traumatic brain injury (TBI) improves neurologic outcomes at 6 months compared with intubation in the hospital. Severe TBI is associated with a high rate of mortality and long-term morbidity. Comatose patients with TBI routinely undergo endo-tracheal intubation to protect the airway, prevent hypoxia, and control ventilation. In many places, paramedics perform intubation prior to hospital arrival. However, it is unknown whether this approach improves outcomes. In a prospective, randomized, controlled trial, we assigned adults with severe TBI in an urban setting to either prehospital rapid sequence intubation by paramedics or transport to a hospital emergency department for intubation by physicians. The primary outcome measure was the median extended Glasgow Outcome Scale (GOSe) score at 6 months. Secondary end-points were favorable versus unfavorable outcome at 6 months, length of intensive care and hospital stay, and survival to hospital discharge. A total of 312 patients with severe TBI were randomly assigned to paramedic rapid sequence intubation or hospital intubation. The success rate for paramedic intubation was 97%. At 6 months, the median GOSe score was 5 (interquartile range, 1-6) in patients intubated by paramedics compared with 3 (interquartile range, 1-6) in the patients intubated at hospital (P = 0.28).The proportion of patients with favorable outcome (GOSe, 5-8) was 80 of 157 patients (51%) in the paramedic intubation group compared with 56 of 142 patients (39%) in the hospital intubation group (risk ratio, 1.28; 95% confidence interval, 1.00-1.64; P = 0.046). There were no differences in intensive care or hospital length of stay, or in survival to hospital discharge. In adults with severe TBI, prehospital rapid sequence intubation by paramedics increases the rate of favorable neurologic outcome at 6 months compared with intubation in the hospital.

  5. [A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation].

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anaesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical

  6. A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation.

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical

  7. Effects of nicardipine on the onset time and intubation conditions of rocuronium-induced neuromuscular blockade.

    PubMed

    Lee, Sun-Yeul; Kim, Yoon-Hee; Ko, Young-Kwon; Park, Sang-Il; Lee, Jung-Un; Chung, Woo-Suk; Lim, Chae-Seong

    2016-08-01

    The objective of this study was to identify the effects of nicardipine on neuromuscular blockade of rocuronium, such as the onset time and intubation conditions, using a nicardipine dose that attenuates cardiovascular responses during endotracheal intubation. Randomized, double-blinded, placebo-controlled clinical comparison was used as the design of this study The study was conducted at the operating room of a university hospital. Participants of this study comprise 78 American Society of Anesthesiologists physical status 1 and 2 patients, aged 18 to 60 years who were undergoing elective surgery under general anesthesia. The nicardipine group was given an intravenous bolus of 20 μg/kg nicardipine before tracheal intubation: the control group was given an intravenous bolus of a comparable volume of normal saline before tracheal intubation. Using a TOF-Watch SX monitor, the time from the end of the injection of rocuronium to maximum depression of T1 (onset time) was measured. Intubation was performed 1 minute after rocuronium administration, and the status of the intubation conditions was assessed. The mean blood pressure and heart rate were each measured after endotracheal intubation. Rate pressure product values were also calculated. Intubation conditions were clinically acceptable in 37 (94.9%) of 39 patients in group N compared with 29 (74.4%) of 39 in group C (P < .05). The onset time of rocuronium was significantly faster in group N than in group C (P < .05). The mean blood pressure was significantly lower in group N than in group C (P < .05). The heart rate was significantly higher in group N than in group C (P < .05). Rate pressure product values showed no significant difference between the two groups (P > .05). Pretreatment with 20 μg/kg nicardipine improves intubation conditions, shortens the onset time of rocuronium, and attenuates cardiovascular responses to tracheal intubation. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Ducted fuel injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, Charles J.

    Various technologies presented herein relate to enhancing mixing inside a combustion chamber to form one or more locally premixed mixtures comprising fuel and charge-gas with low peak fuel to charge-gas ratios to enable minimal, or no, generation of soot and other undesired emissions during ignition and subsequent combustion of the locally premixed mixtures. To enable sufficient mixing of the fuel and charge-gas, a jet of fuel can be directed to pass through a bore of a duct causing charge-gas to be drawn into the bore creating turbulence to mix the fuel and the drawn charge-gas. The duct can be locatedmore » proximate to an opening in a tip of a fuel injector. The duct can comprise of one or more holes along its length to enable charge-gas to be drawn into the bore, and further, the duct can cool the fuel and/or charge-gas prior to combustion.« less

  9. An active simulator for neonatal intubation: Design, development and assessment.

    PubMed

    Baldoli, Ilaria; Tognarelli, Selene; Vangi, Ferdinando; Panizza, Davide; Scaramuzzo, Rosa T; Cuttano, Armando; Laschi, Cecilia; Menciassi, Arianna

    2017-01-01

    This study describes the technical realization and the pre-clinical validation of a instrumented neonatal intubation skill trainer able to provide objective feedback for the improvement of clinical competences required for such a delicate procedure. The Laerdal ® Neonatal Intubation Trainer was modified by applying pressure sensors on areas that are mainly subject to stress and potential injuries. Punctual Force Sensing Resistors (FSRs) were characterized and fixed on the external side of the airway structure on the dental arches and epiglottis. A custom silicone tongue was designed and developed to integrate a matrix textile sensor for mapping the pressure applied on its whole surface. The assessment of the developed tool was performed by nine clinical experts who were asked to practice three intubation procedures apiece. Median and maximum forces, over threshold events (i.e. 2N for gingival arch sensors and 7N for epiglottis and tongue sensors respectively) and execution time were measured for each trainee. Data analysis from training sessions revealed that the epiglottis is the point mainly stressed during an intubation procedure (maximum value: 16.69N, median value: 3.11N), while the analysis carried out on the pressure distribution on the instrumented tongue provided information on both force values and distribution, according to clinicians' performance. The debriefing phase was used to enhance the clinicians' awareness of applied force and gestures performed, confirming that the present study is an adequate starting point for achieving and optimizing neonatal intubation skills for both residents and expert clinicians. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Head-Elevated Patient Positioning Decreases Complications of Emergent Tracheal Intubation in the Ward and Intensive Care Unit.

    PubMed

    Khandelwal, Nita; Khorsand, Sarah; Mitchell, Steven H; Joffe, Aaron M

    2016-04-01

    Based on the data from elective surgical patients, positioning patients in a back-up head-elevated position for preoxygenation and tracheal intubation can improve patient safety. However, data specific to the emergent setting are lacking. We hypothesized that back-up head-elevated positioning would be associated with a decrease in complications related to tracheal intubation in the emergency room environment. This retrospective study was approved by the University of Washington Human Subjects Division (Seattle, WA). Eligible patients included all adults undergoing emergent tracheal intubation outside of the operating room by the anesthesiology-based airway service at 2 university-affiliated teaching hospitals. All intubations were through direct laryngoscopy for an indication other than full cardiopulmonary arrest. Patient characteristics and details of the intubation procedure were derived from the medical record. The primary study endpoint was the occurrence of a composite of any intubation-related complication: difficult intubation, hypoxemia, esophageal intubation, or pulmonary aspiration. Multivariable logistic regression was used to estimate the odds of the primary endpoint in the supine versus back-up head-elevated positions with adjustment for a priori-defined potential confounders (body mass index and a difficult intubation prediction score [Mallampati, obstructive sleep Apnea, Cervical mobility, mouth Opening, Coma, severe Hypoxemia, and intubation by a non-Anesthesiologist score]). Five hundred twenty-eight patients were analyzed. Overall, at least 1 intubation-related complication occurred in 76 of 336 (22.6%) patients managed in the supine position compared with 18 of 192 (9.3%) patients managed in the back-up head-elevated position. After adjusting for body mass index and the Mallampati, obstructive sleep Apnea, Cervical mobility, mouth Opening, Coma, severe Hypoxemia, and intubation by a non-Anesthesiologist score, the odds of encountering the

  11. A canine model of tracheal stenosis induced by cuffed endotracheal intubation

    PubMed Central

    Su, Zhuquan; Li, Shiyue; Zhou, Ziqing; Chen, Xiaobo; Gu, Yingying; Chen, Yu; Zhong, Changhao; Zhong, Minglu; Zhong, Nanshan

    2017-01-01

    Postintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal stenosis remain not fully understood. We aimed to establish an animal model and to investigate risk factors for postintubation tracheal stenosis. Beagles were intubated with 4 sized tubes (internal diameter 6.5 to 8.0 mm) and cuff pressures of 100 to 200 mmHg for 24 hr. The status of tracheal wall was evaluated by bronchoscopic and histological examinations. The model was successfully established by cuffed endotracheal intubation using an 8.0 mm tube and an intra-cuff pressure of 200 mmHg for 24 hr. When the intra-cuff pressures were kept constant, a larger sized tube would induce a larger tracheal wall pressure and more severe injury to the tracheal wall. The degree of tracheal stenosis ranged from 78% to 91% at 2 weeks postextubation. Histological examination demonstrated submucosal infiltration of inflammatory cells, hyperplasia of granulation tissue and collapse of tracheal cartilage. In summary, a novel animal model of tracheal stenosis was established by cuffed endotracheal intubation, whose histopathological feathers are similar to those of clinical cases of postintubation tracheal stenosis. Excessive cuff pressure and over-sized tube are the risk factors for postintubation tracheal stenosis. PMID:28349955

  12. A comparison of GlideScope(®) videolaryngoscopy and direct laryngoscopy for nasotracheal intubation in children.

    PubMed

    Kim, Hyun-Jung; Kim, Jin-Tae; Kim, Hee-Soo; Kim, Chong-Sung; Kim, Seong-Deok

    2011-04-01

    The relative effectiveness of GlideScope(®) videolaryngoscopy (GV) for nasotracheal intubation in pediatric patients is unclear. The purpose of this study is to evaluate the usefulness of GV for nasotracheal intubation compared with direct laryngoscopy (DL) in pediatric patients. Our patient cohort consisted of 80 children <10 years of age who required nasotracheal intubation for elective dental or facial surgery. The patients were randomly allocated to GV (n = 40) or DL (n = 40) group. The time to intubation (TTI), glottic view grade, frequency of Magill forceps use, and degree of difficulty in intubation were evaluated. The median TTI was similar between the groups. The TTI of the former 20 patients was faster in the DL group (53.3 s, interquartile range: 42.0-64.3) than GV group (65.9 s, interquartile range: 56.0-93.9) (P = 0.007), whereas the TTI of the latter 20 patients was comparable between the groups. There were no significant differences in glottic view grade, frequency of Magill forceps use, and degree of difficulty in intubation between the two groups. GV can provide similar intubation performance characteristics compared with DL when used for nasotracheal intubation in pediatric patients. However, experience is needed to be skillful in the GV to acquire comparable TTI with DL. © 2011 Blackwell Publishing Ltd.

  13. Submental Orotracheal Intubation in Maxillofacial Fracture Surgery: Report of Two Cases

    PubMed Central

    Tekelioğlu, Ümit Yaşar; Karabekmez, Furkan Erol; Demirhan, Abdullah; Akkaya, Akcan; Bayır, Hakan; Koçoğlu, Hasan

    2013-01-01

    Two patients, aged 18 and 28 years, with maxillofacial trauma due to motor vehicle accident, were operated upon by a team of plastic surgeons. In this report we aimed to present our experience with submental intubation procedure in these cases, in which orotracheal or nasotracheal intubation was impossible due to panfacial fracture. PMID:27366379

  14. Optimizing Electrospray Interfaces Using Slowly Diverging Conical Duct (ConDuct) Electrodes

    PubMed Central

    Krutchinsky, Andrew N.; Padovan, Júlio C.; Cohen, Herbert; Chait, Brian T.

    2015-01-01

    We demonstrate that the efficiency of ion transmission from atmosphere to vacuum through stainless steel electrodes that contain slowly divergent conical duct (ConDuct) channels can be close to 100%. Here, we explore the properties of 2.5 cm long electrodes with angles of divergence of 0°, 1°, 2°, 3°, 5°, 8°, 13°, and 21°, respectively. The ion transmission efficiency was observed to jump from 10–20% for the 0° (straight) channels to 90–95% for channels with an angle of divergence as small as 1°. Furthermore, the 2–3° ConDuct electrodes produced extraordinarily low divergence ion beams that propagated in a laser-like fashion over long distances in vacuum. To take advantage of these newly discovered properties, we constructed a novel atmosphere-to-vacuum ion interface utilizing a 2° ConDuct as an inlet electrode and compared its ion transmission efficiency with that of the interface used in the commercial (Thermo) Velos Orbitrap and Q Exactive mass spectrometers. We observed that the ConDuct interface transmitted up to 17 times more ions than the commercial reference interface and also yielded improved signal-to-noise mass spectra of peptides. We infer from these results that the performance of many current atmosphere-tovacuum interfaces utilizing metal capillaries can be substantially improved by replacing them with 1° or 2° metal ConDuct electrodes, which should preserve the convenience of supplying ion desolvation energy by heating the electrode while greatly increasing the efficiency of ion transmission into the mass spectrometer. PMID:25667060

  15. Optimizing Electrospray Interfaces Using Slowly Diverging Conical Duct (ConDuct) Electrodes

    NASA Astrophysics Data System (ADS)

    Krutchinsky, Andrew N.; Padovan, Júlio C.; Cohen, Herbert; Chait, Brian T.

    2015-04-01

    We demonstrate that the efficiency of ion transmission from atmosphere to vacuum through stainless steel electrodes that contain slowly divergent conical duct (ConDuct) channels can be close to 100%. Here, we explore the properties of 2.5-cm-long electrodes with angles of divergence of 0°, 1°, 2°, 3°, 5°, 8°, 13°, and 21°, respectively. The ion transmission efficiency was observed to jump from 10-20% for the 0° (straight) channels to 90-95% for channels with an angle of divergence as small as 1°. Furthermore, the 2-3° ConDuct electrodes produced extraordinarily low divergence ion beams that propagated in a laser-like fashion over long distances in vacuum. To take advantage of these newly discovered properties, we constructed a novel atmosphere-to-vacuum ion interface utilizing a 2° ConDuct as an inlet electrode and compared its ion transmission efficiency with that of the interface used in the commercial (Thermo Fisher Scientific, San Jose, CA, USA) Velos Orbitrap and Q Exactive mass spectrometers. We observed that the ConDuct interface transmitted up to 17 times more ions than the commercial reference interface and also yielded improved signal-to-noise mass spectra of peptides. We infer from these results that the performance of many current atmosphere-to-vacuum interfaces utilizing metal capillaries can be substantially improved by replacing them with 1° or 2° metal ConDuct electrodes, which should preserve the convenience of supplying ion desolvation energy by heating the electrode while greatly increasing the efficiency of ion transmission into the mass spectrometer.

  16. PMR Graphite Engine Duct Development

    NASA Technical Reports Server (NTRS)

    Stotler, C. L.; Yokel, S. A.

    1989-01-01

    The objective was to demonstrate the cost and weight advantages that could be obtained by utilizing the graphite/PMR15 material system to replace titanium in selected turbofan engine applications. The first component to be selected as a basis for evaluation was the outer bypass duct of the General Electric F404 engine. The operating environment of this duct was defined and then an extensive mechanical and physical property test program was conducted using material made by processing techniques which were also established by this program. Based on these properties, design concepts to fabricate a composite version of the duct were established and two complete ducts fabricated. One of these ducts was proof pressure tested and then run successfully on a factory test engine for over 1900 hours. The second duct was static tested to 210 percent design limit load without failure. An improved design was then developed which utilized integral composite end flanges. A complete duct was fabricated and successfully proof pressure tested. The net results of this effort showed that a composite version of the outer duct would be 14 percent lighter and 30 percent less expensive that the titanium duct. The other type of structure chosen for investigation was the F404 fan stator assembly, including the fan stator vanes. It was concluded that it was feasible to utilize composite materials for this type structure but that the requirements imposed by replacing an existing metal design resulted in an inefficient composite design. It was concluded that if composites were to be effectively used in this type structure, the design must be tailored for composite application from the outset.

  17. Diagnosis of nosocomial pneumonia in intubated, intensive care unit patients.

    PubMed

    Salata, R A; Lederman, M M; Shlaes, D M; Jacobs, M R; Eckstein, E; Tweardy, D; Toossi, Z; Chmielewski, R; Marino, J; King, C H

    1987-02-01

    The clinical distinction between bacterial colonization of the tracheobronchial tree and nosocomial pneumonia is difficult, especially in intubated patients. We studied 51 intubated, intensive care unit patients prospectively by serial examinations of tracheal aspirates for elastin fibers, graded Gram's stains, and quantitative bacterial cultures in conjunction with clinical and radiologic observations in an attempt to develop criteria for the early detection of pulmonary infection. Patients with infection had new or progressive pulmonary infiltrates plus 1 of the following: positive blood culture results, radiographic evidence of cavitation, or histologic evidence of pneumonia, or 2 or more of the following: new fever, new leukocytosis, or grossly purulent tracheal aspirates. Twenty-one patients developed infection, 22 remained colonized, and 8 had an uncertain status. Infiltrates developed in 34 patients (21 infected, 8 colonized, 5 uncertain status). Gram-negative bacilli were most commonly isolated and were more frequent in infected patients (81 versus 47%, p less than 0.05); Pseudomonas aeruginosa and Serratia marcescens were most often associated with infection. No differences were observed between infected and colonized patients in demographic features, smoking history, underlying disease, previous antibiotic therapy, days in hospital before intubation, preexisting pneumonia upon intubation, or highest temperature or leukocyte count during course. By univariate analysis, infected patients had a longer duration of intubation (p less than 0.05), higher Gram's stain grading for neutrophils (p less than 0.05) or bacteria (p less than 0.005), higher bacterial colony counts (p less than 0.05), and more frequent detection of elastin fibers in tracheal aspirates (p less than 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Simple resection of the lesion bile duct branch for treatment of regional hepatic bile duct stones

    PubMed Central

    Enliang, Li; Rongshou, Wu; Shidai, Shi; Jingling, Zhang; Qian, Feng; Wenjun, Liao; Linquan, Wu

    2017-01-01

    Abstract To evaluate the effectiveness and safety of simple resections of bile duct branch lesions for the treatment of regional hepatic bile duct stones. A retrospective analysis of the clinical data from patients in our hospital from November 2008 to November 2015, who only underwent a simple resection of the lesion bile duct branch. The patients’ clinical characteristics, surgical features, postoperative complications, stone clear rate, residual stone rate, and recurrence stone rate were analyzed. This study of 32 patients included 13 males and 19 females with intrahepatic bile duct stones confined to the right hepatic bile duct branch. The intraoperative blood loss, operation time, and postoperative hospital stay were 478.0 ± 86.5, 210.7 ± 6.6, and 10.8 ± 3.5, respectively. Postoperative complications occurred in 6 patients (18.8%), all of whom recovered with conservative management. There were no deaths during hospitalization. The intraoperative stone clearance rate was 95.8%. Three patients had a recurrence of stones at a mean of 22 months of follow-up (range, 4–36 months). Simple resection of bile duct branch lesions is safe and feasible for patients who have regional hepatic bile duct stones limited to the right hepatic bile duct branches. PMID:28682899

  19. Post-intubation sore throat and menstruation cycles.

    PubMed

    Orandi, Amirali; Orandi, Amirhossein; Najafi, Atabak; Hajimohammadi, Fatemeh; Soleimani, Sara; Zahabi, Somayeh

    2013-09-01

    Postoperative sore throat is one of the most common complications of general anesthesia and intubation with prevalence of 18%-65% in different studies. Several risk factors including female gender, postoperative nausea and vomiting and so on have been mentioned. The aim of this study was to evaluate the incidence of postoperative sore throat in females and its association with menstrual cycles. One hundred females between 18-45 years old with ASA class I or II without predicted difficult airway that were candidate for operation in supine position were enrolled in study. Patients who had pulmonary disease, smoking, common cold within two weeks prior to the operation, previous traumatic intubation history, removable dentures, any congenital or acquired deformity in face, neck, mouth and airway, any known pathology in mouth like aphthous and mouth ulcer,pregnant women, and patients with irregular cycles, and those taking oral contraceptive pills were excluded. By the same protocol general anesthesia was provided and the patients were asked to fill out a three-point scale questionnaire (Low, High, None) 1,6 and 24 hours following intubation to study and record the incidence and severity of sore throat, dysphagia and hoarseness. The date of last menstrual period had been recorded as well. Of 100 patients, in the first six hours, 51 patients had sore throat and 49 had no pain. During the first 6 hours, 33 patients (33%) had dysphagia and 13 patients had hoarseness at 6th postoperative hour. Age, weight, LMP, intubation time, operation and extubation time and coughing were compared to sore throat, dysphagia and hoarseness. The association between the incidence of coughing and bucking and sore throat was significant (P = 0.03). None of the parameters had a statistically meaningful association with dysphagia. According to our results, by omitting probable risk factors of incidence of sore throat and evaluation of role of hormonal changes in women represented in menstrual

  20. A pilot study of the effect of pressure-driven lidocaine spray on airway topical anesthesia for conscious sedation intubation.

    PubMed

    Jiang, Hai; Miao, Hai-Sheng; Jin, San-Qing; Chen, Li-Hong; Tian, Jing-Ling

    2011-12-01

    Difficult airway remains not only a challenge to the anesthesiologists, but also a life-threatening event to the patients. Awake intubation is the principal choice to deal with difficult airway, and a key point for awake intubation is airway topical anesthesia. Yet, so far there is no ideal topical anesthesia approach for awake intubation. This study aimed at evaluating the effect of pressure-driven (by 10 L/min oxygen flow) lidocaine spray on airway topical anesthesia in order to find a powerful and convenient method for airway topical anesthesia for conscious sedation intubation. Thirty adult patients referred for elective surgery under general anesthesia, aged 18 - C60 years and Mallampati class I or II, were recruited for the study. Before topical anesthesia, the observer's assessment of alert and sedation (OAA/S) scale was controlled between 3 and 4 by intravenous midazolam (0.03 mg/kg), propofol (2 mg×kg(-1)×h(-1)) and remifentanil (0.05 µg×kg(-1)×min(-1)). Ten minutes after sedation, topical anesthesia was performed with the pressure-driven lidocaine spray; the driving pressure was achieved by an oxygen flow of 10 L/min. After topical anesthesia, tracheal intubation was performed and the intubation condition was assessed with modified the Erhan's intubation condition score by an experienced anesthesiologist, and a score of less than 10 was considered to be satisfactory. Attempts to intubate the patient were recorded, and the complications such as local anesthetic toxicity, mucosa injury, and respiration depression were also recorded. The mean arterial blood pressure (MAP), heart rate (HR) and pulse oxygen saturation (SpO2) were recorded at different time points before and after intubation. Patients were asked 24 hours after the operation whether they could recall the events during intubation. All patients were intubated at the first attempt, the average intubation condition score was 7.0 ± 1.1, from 6 to 10, satisfied intubation condition. MAP and HR

  1. Turbofan aft duct suppressor study

    NASA Technical Reports Server (NTRS)

    Syed, A. A.; Motsinger, R. E.; Fiske, G. H.; Joshi, M. C.; Kraft, R. E.

    1983-01-01

    Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.

  2. Eversion Bile Duct Anastomosis: A Safe Alternative for Bile Duct Size Discrepancy in Deceased Donor Liver Transplantation.

    PubMed

    Leal-Leyte, Pilar; McKenna, Greg J; Ruiz, Richard M; Anthony, Tiffany L; Saracino, Giovanna; Giuliano, Testa; Klintmalm, Goran B; Kim, Peter Tw

    2018-04-10

    Introduction Bile duct size discrepancy in liver transplantation may increase the risk of biliary complications. The aim of this study was to evaluate the safety and outcomes of the eversion bile duct anastomosis technique in deceased donor liver transplantation (DDLT) with duct to duct anastomosis. Methods A total of 210 patients who received a DDLT with duct to duct anastomosis from 2012 to 2017 were divided into two groups: those who had eversion bile duct anastomosis (N=70) and standard bile duct anastomosis (N=140). Biliary complications rates were compared between the two groups. Results There was no difference in the cumulative incidence of biliary strictures (P=0.20) and leaks (P=0.17) between the two groups. The biliary complication rate in the eversion group was 14.3% and 11.4% in the standard anastomosis group. All the biliary complications in the eversion group were managed with endoscopic stenting. A severe size mismatch (≥3:1 ratio) was associated with a significantly higher incidence of biliary strictures (44.4%) compared to 2:1 ratio (8.2%), (P=0.002). Conclusion The use of the eversion technique is a safe alternative for bile duct discrepancy in deceased donor liver transplantation; however, severe bile duct size mismatch may be a risk factor for biliary strictures with such technique. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.

  3. [Difficult Ventilation Requiring Emergency Endotracheal Intubation during Awake Craniotomy Managed by Laryngeal Mask Airway].

    PubMed

    Matsuda, Asako; Mizota, Toshiyuki; Tanaka, Tomoharu; Segawa, Hajime; Fukuda, Kazuhiko

    2016-04-01

    We report a case of difficult ventilation requiring emergency endotracheal intubation during awake craniotomy managed by laryngeal mask airway (LMA). A 45-year-old woman was scheduled to receive awake craniotomy for brain tumor in the frontal lobe. After anesthetic induction, airway was secured using ProSeal LMA and patient was mechanically ventilated in pressure-control mode. Patient's head was fixed with head-pins at anteflex position, and the operation started. About one hour after the start of the operation, tidal volume suddenly decreased. We immediately started manual ventilation, but the airway resistance was extremely high and we could not adequately ventilate the patient. We administered muscle relaxant for suspected laryngospasm, but ventilatory status did not improve; so we decided to conduct emergency endotracheal intubation. We tried to intubate using Airwayscope or LMA-Fastrach, but they were not effective in our case. Finally trachea was intubated using transnasal fiberoptic bronchoscopy. We discuss airway management during awake craniotomy, focusing on emergency endotracheal intubation during surgery.

  4. Bilateral congenital lacrimal fistulas in an adult as part of ectrodactyly-ectodermal dysplasia-clefting syndrome: A rare anomaly.

    PubMed

    Ghosh, Debangshu; Saha, Somnath; Basu, Sumit Kumar

    2015-10-01

    Ectrodactyly-ectodermal dysplasia and clefting syndrome or "Lobster claw" deformity is a rare congenital anomaly that affects tissues of ectodermal and mesodermal origin. Nasolacrimal duct (NLD) obstruction with or without atresia of lacrimal passage is a common finding of such a syndrome. The authors report here even a rarer presentation of the syndrome which manifested as bilateral NLD obstruction and lacrimal fistula along with cleft lip and palate, syndactyly affecting all four limbs, mild mental retardation, otitis media, and sinusitis. Lacrimal duct obstruction and fistula were managed successfully with endoscopic dacryocystorhinostomy (DCR) which is a good alternative to lacrimal probing or open DCR in such a case.

  5. Intubation conditions in young infants after propofol and remifentanil induction with and without low-dose rocuronium.

    PubMed

    Gelberg, J; Kongstad, L; Werner, O

    2014-08-01

    Bolus injections of intravenous propofol and remifentanil can be used in the tracheal intubation of infants and children, but relatively large doses are needed. We hypothesised that addition of a small bolus of rocuronium would ensure good intubation conditions when modest propofol and remifentanil doses were used. Seventy infants between 3 weeks and 4 months of age were randomised to receive either placebo or rocuronium. Anaesthesia was induced with IV propofol, 3 (3-5) mg/kg [median (range)]. Rocuronium (0.2 mg/kg) or placebo was then injected, followed 15 s later by 2 μg/kg remifentanil. One anaesthetist attempted tracheal intubation 1 min after the rocuronium/placebo injection and used the 'Copenhagen scoring system' to assess intubation conditions. The neuromuscular effect of 0.2 mg/kg rocuronium was recorded in another eight, already intubated, infants using thumb accelerometry during train-of-four stimulation of the ulnar nerve. Intubation conditions were classified as 'poor' in 14 of 34 (41%) patients given placebo and in 10 of 36 (28%) patients given rocuronium (P = 0.32). There were four failed first attempts at intubation in the placebo group and none in the rocuronium group (P = 0.051). Maximum neuromuscular depression occurred 4 (3-8) after injection of 0.2 mg/kg rocuronium. Intubation conditions were poor in almost one third of the patients receiving propofol-remifentanil. Adding a low-dose rocuronium did not significantly improve intubation conditions. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. [Inductions and intubating conditions with sevoflurane and different doses of remifentanil without muscle relaxant in children].

    PubMed

    Wei, Ling-Xin; Deng, Xiao-Ming; Liu, Ju-Hui; Luo, Mao-Ping; Tong, Shi-Yi; Zhang, Yan-Ming; Liao, Xu; Xu, Kun-Lin

    2008-12-01

    To observe the clinical effectiveness of inductions and tracheal intubating conditions with 3% sevoflurane and different doses of remifentanil without muscle relaxant in children. Totally 120 peadiatric patients (aged 4-10 years, American Society of Anesthesiologists grade I for inhalational induction) were randomly allocated into group I (remifentanil 1 microg/kg), group II (remifentanil 2 microg/kg), group III (remifentanil 3 microg/kg), and control group (vecuronium bromide 0.1 mg/kg). After inhalational induction with 3% sevoflurane and 60% nitrous oxide in 40% oxygen for 2 minutes, remifentanil 1 microg/kg, 2 microg/ kg, and 3 microg/kg were intravenously injected over 1 minute into patients in group I , group II, and group III, respectively. After remifentanil administration and manual ventilation for 1 minute, the trachea was intubated. In the control group, 2 minutes after intravenous administration of vecuronium bromide 0.1 mg/kg, tracheal intubation was attempted. Agitation, intubating satisfactoriness, and the circulation changes after tracheal intubation and anesthesia induction were observed. In these four groups, agitation occurred in 37.5% of patients during sevoflurane induction. Satisfactory intubation rate was 70.0% in group I, 86.7% in group II, 90.0% in group III, and 93.3% in the control group. Compared with the control group, the impact of tracheal intubation on the circulatory system was smaller in group I , II , and III. Induction with 3% sevoflurane combined with remifentanil can be smoothly performed, followed by the successful tracheal intubation. The intubating conditions are more satisfactory with 3% sevoflurane combined with remifentanil 2 microg/kg or 3 microg/kg.

  7. T-tube drainage of the common bile duct choleperitoneum: etiology and management.

    PubMed

    Daldoul, S; Moussi, A; Zaouche, A

    2012-06-01

    External drainage of the common bile duct by placement of a T-tube is a common practice after choledochotomy. This practice may result in the specific complication of bile peritonitis due to leakage after removal of the T-tube. This complication has multiple causes: some are patient-related (corticotherapy, chemotherapy, ascites), and others are due to technical factors (inappropriate suturing of the drain to the ductal wall, minimal inflammatory reaction related to some drain materials). The clinical presentation is quite variable depending on the amount and rapidity of intra-peritoneal spread of of bile leakage. Abdominal ultrasound (US), with US-guided needle aspiration and occasionally Technetium(99) scintigraphy are useful for diagnosis. Traditional therapy consists of surgical intervention including peritoneal lavage and re-intubation of the choledochal fistulous tract to allow for a further period of external drainage. When leakage is walled off and well-tolerated, a more nuanced and less invasive conservative therapy may combine percutaneous drainage with endoscopic placement of a trans-ampullary biliary drainage. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  8. Basic needs and their predictors for intubated patients in surgical intensive care units.

    PubMed

    Liu, Jin-Jen; Chou, Fan-Hao; Yeh, Shu-Hui

    2009-01-01

    This study was conducted to investigate the basic needs and communication difficulties of intubated patients in surgical intensive care units (ICUs) and to identify predictors of the basic needs from the patient characteristics and communication difficulties. In this descriptive correlational study, 80 surgical ICU patients were recruited and interviewed using 3 structured questionnaires: demographic information, scale of basic needs, and scale of communication difficulties. The intubated patients were found to have moderate communication difficulties. The sense of being loved and belonging was the most common need in the intubated patients studied (56.00 standardized scores). A significantly positive correlation was found between communication difficulties and general level of basic needs (r = .53, P < .01), and another positive correlation was found between the length of stay in ICUs and the need for love and belonging (r = .25, P < .05). The basic needs of intubated patients could be significantly predicted by communication difficulties (P = .002), use of physical restraints (P = .010), lack of intubation history (P = .005), and lower educational level (P = .005). These 4 predictors accounted for 47% of the total variance in basic needs. The intubated patients in surgical ICUs had moderate basic needs and communication difficulties. The fact that the basic needs could be predicted by communication difficulties, physical restraints, and educational level suggests that nurses in surgical ICUs need to improve skills of communication and limit the use of physical restraints, especially in patients with a lower educational level.

  9. Effects of fenoterol and ipratropium on respiratory resistance of asthmatics after tracheal intubation.

    PubMed

    Wu, R S; Wu, K C; Wong, T K; Tsai, Y H; Cheng, R K; Bishop, M J; Tan, P P

    2000-03-01

    We have studied the effects of a beta-agonist, fenoterol, and a cholinergic antagonist, ipratropium, on post-intubation total respiratory system resistance (Rrs) in asthmatics who developed increased Rrs after tracheal intubation. Sixteen stable asthmatics in whom Rrs increased after intubation were allocated randomly to receive either 10 puffs of fenoterol (group F) or 10 puffs of ipratropium (group IB) via a metered dose inhaler 5 min after intubation. Anaesthesia was induced and maintained with propofol i.v. Rrs was recorded before treatment and again 5, 15 and 30 min after treatment. Rrs decreased significantly from pretreatment values by mean 53 (SD 8)%, 53 (7)% and 58 (6)% at 5, 15 and 30 min, respectively, in group F, but declined by only 12 (6)%, 15 (4)% and 17 (5)% in group IB. At all times after treatment, patients in the fenoterol group had significantly lower Rrs values than those in the ipratropium group. We conclude that increased Rrs after tracheal intubation in asthmatics can be reduced effectively by treatment with fenoterol. A secondary finding of our study was that even after induction of anaesthesia with propofol, patients with a history of asthma may develop high Rrs.

  10. May we practise endotracheal intubation on the newly dead?

    PubMed Central

    Ardagh, M

    1997-01-01

    Endotracheal intubation (ETI) is a valuable procedure which must be learnt and practised, and performing ETI on cadavers is probably the best way to do this, although lesser alternatives do exist. Performing ETI on a cadaver is viewed with a real and reasonable repugnance and if it is done without proper authorisation it might be illegal. Some form of consent is required. Presumed consent would preferably be governed by statute and should only occur if the community is well informed and therefore in a position of being able to decline. Currently neither statute nor adequate informing exists. Endotracheal intubation on the newly dead may be justifiable according to a Guttman scale if the patient has already consented to organ donation and if further research supports the relevance of the Guttman scale to this question. A "mandated choice" with prior individual consent as a matter of public policy is the best of these solutions, however until such a solution is in place we may not practise endotracheal intubation on the newly dead. PMID:9358348

  11. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1995-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has-four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  12. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1997-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  13. Simple and fast orotracheal intubation procedure in rats.

    PubMed

    Tomasello, Giovanni; Damiani, Francesco; Cassata, Giovanni; Palumbo, Vincenzo Davide; Sinagra, Emanuele; Damiani, Provvidenza; Bruno, Antonino; Cicero, Luca; Cupido, Francesco; Carini, Francesco; Lo Monte, Attilio Ignazio

    2016-05-06

    Endotracheal intubation in the rat is difficult because of the extremely small size of anatomical structures (oral cavity, epiglottis and vocal cords), small inlet for an endotracheal tube and the lack of proper technical instruments. In this study we used seventy rats weighting 400-500 g. The equipment needed for the intubation was an operating table, a longish of cotton, a cotton tip, orotracheal tube, neonatal laryngoscope blades, KTR4 small animal ventilator and isoflurane for inhalation anaesthesia. Premedication was carried out by medetomidine hydrochloride 1 mg/mL; then, thanks to a closed glass chamber, a mixture of oxygen and isoflurane was administered. By means of a neonatal laryngoscope the orotracheal tube was advanced into the oral cavity until the wire guide was visualized trough the vocal cords; then it was passed through them. The tube was introduced directly into the larynx over the wire guide; successively, the guide was removed and the tube placed into the trachea. Breathing was confirmed using a glove, cut at the end of a finger, simulating a small balloon. We achieved a fast and simple orotracheal intubation in all animals employed. We believe that our procedure is easier and faster than those previously reported in scientific literature.

  14. Out-of-hospital tracheal intubation with single-use versus reusable metal laryngoscope blades: a multicenter randomized controlled trial.

    PubMed

    Jabre, Patricia; Galinski, Michel; Ricard-Hibon, Agnes; Devaud, Marie Laure; Ruscev, Mirko; Kulstad, Erik; Vicaut, Eric; Adnet, Fréderic; Margenet, Alain; Marty, Jean; Combes, Xavier

    2011-03-01

    Emergency tracheal intubation is reported to be more difficult with single-use plastic than with reusable metal laryngoscope blades in both inhospital and out-of-hospital settings. Single-use metal blades have been developed but have not been compared with conventional metal blades. This controlled trial compares the efficacy and safety of single-use metal blades with reusable metal blades in out-of-hospital emergency tracheal intubation. This randomized controlled trial was carried out in France with out-of-hospital emergency medical units (Services de Médecine d'Urgence et de Réanimation). This was a multicenter prospective noninferiority randomized controlled trial in adult out-of-hospital patients requiring emergency tracheal intubation. Patients were randomly assigned to either single-use or reusable metal laryngoscope blades and intubated by a senior physician or a nurse anesthetist. The primary outcome was first-pass intubation success. Secondary outcomes were incidence of difficult intubation, need for alternate airway devices, and early intubation-related complications (esophageal intubation, mainstem intubation, vomiting, pulmonary aspiration, dental trauma, bronchospasm or laryngospasm, ventricular tachycardia, arterial desaturation, hypotension, or cardiac arrest). The study included 817 patients, including 409 intubated with single-use blades and 408 with a reusable blade. First-pass intubation success was similar in both groups: 292 (71.4%) for single-use blades, 290 (71.1%) for reusable blades. The 95% confidence interval (CI) for the difference in treatments (0.3%; 95% CI -5.9% to 6.5%) did not include the prespecified inferiority margin of -7%. There was no difference in rate of difficult intubation (difference 3%; 95% CI -7% to 2%), need for alternate airway (difference 4%; 95% CI -8% to 1%), or early complication rate (difference 3%; 95% CI -3% to 8%). First-pass out-of-hospital tracheal intubation success with single-use metal laryngoscopy

  15. Endotracheal intubation using the C-MAC® video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU

    PubMed Central

    2012-01-01

    Introduction Endotracheal intubation in the ICU is a challenging procedure and is frequently associated with life-threatening complications. The aim of this study was to investigate the effect of the C-MAC® video laryngoscope on laryngeal view and intubation success compared with direct laryngoscopy. Methods In a single-center, prospective, comparative before-after study in an anesthetist-lead surgical ICU of a tertiary university hospital, predictors of potentially difficult tracheal intubation, number of intubation attempts, success rate and glottic view were evaluated during a 2-year study period (first year, Macintosh laryngoscopy (ML); second year, C-MAC®). Results A total of 274 critically ill patients requiring endotracheal intubation were included; 113 intubations using ML and 117 intubations using the C-MAC® were assessed. In patients with at least one predictor for difficult intubation, the C-MAC® resulted in more successful intubations on first attempt compared with ML (34/43, 79% vs. 21/38, 55%; P = 0.03). The visualization of the glottis with ML using Cormack and Lehane (C&L) grading was more frequently rated as difficult (20%, C&L grade 3 and 4) compared with the C-MAC® (7%, C&L grade 3 and 4) (P < 0.0001). Conclusion Use of the C-MAC® video laryngoscope improved laryngeal imaging and improved the intubating success rate on the first attempt in patients with predictors for difficult intubation in the ICU setting. Video laryngoscopy seems to be a useful tool in the ICU where potentially difficult endotracheal intubations regularly occur. PMID:22695007

  16. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

    PubMed

    Qureshi, Mosarrat J; Kumar, Manoj

    2018-03-15

    Providing effective positive pressure ventilation is considered to be the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated manually with bag and face mask (BMV) followed by endotracheal intubation if respiratory depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or neonatal asphyxia. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation. Among newborns requiring positive pressure ventilation for cardio-pulmonary resuscitation, is LMA more effective than BMV or endotracheal intubation for successful resuscitation? When BMV is either insufficient or ineffective, is effective positive pressure ventilation and successful resuscitation achieved faster with the LMA compared to endotracheal intubation? We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2017, Issue 1), MEDLINE via PubMed (1966 to 15 February 2017), Embase (1980 to 15 February 2017), and CINAHL (1982 to 15 February 2017). We also searched clinical trials registers, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. We included randomised and quasi-randomised controlled trials that compared LMA for neonatal resuscitation with either BMV or endotracheal intubation and reported on any outcomes related to neonatal resuscitation specified in this review. Two review authors independently evaluated studies for risk of bias assessments, and extracted data using Cochrane Neonatal criteria. Categorical treatment effects were described as relative risks and continuous treatment effects were described as the mean difference, with 95% confidence intervals (95% CI) of estimates. We included seven trials that involved a total of 794 infants. Five

  17. Non-intubated uniportal left-lower lobe upper segmentectomy (S6).

    PubMed

    Galvez, Carlos; Navarro-Martinez, Jose; Bolufer, Sergio; Sesma, Julio; Lirio, Francisco; Galiana, Maria; Rivera, Maria Jesus

    2017-01-01

    Worldwide accepted indications of anatomical segmentectomies are mainly early stage primary adenocarcinomas, pulmonary metastasis and benign conditions. Their performance through uniportal VATS has become more and more popular due to the less invasiveness of the whole procedure under this approach. Recently, many efforts have focused on non-intubated spontaneously breathing management of lobectomies and anatomical segmentectomies, although specific selection criteria and main advantages are not completely standardized. In a 62-year-old thin man with two pulmonary residual metastasis from sigma adenocarcinoma, after chemotherapy plus antiangiogenic treatment, we indicated a single-incision video-assisted left-lower lobe (LLL) upper segmentectomy (S6) under spontaneous breathing and intercostal blockade. Total operation time was 240 minutes. Chest tube was removed at 24 hours and the patient was discharge on postoperative day 2 without any complication. Non-intubated uniportal VATS is a safe and reasonable approach for lung-sparing resections in selected patients, although more evidence is required for selecting which patients can benefit more over standard intubated procedures.

  18. [Difficult fiberoptic tracheal intubation in 1 month-old infant with Treacher Collins Syndrome].

    PubMed

    Fuentes, Ricardo; De la Cuadra, Juan Carlos; Lacassie, Hector; González, Alejandro

    Neonates and small infants with craniofacial malformation may be very difficult or impossible to mask ventilate or intubate. We would like to report the fiberoptic intubation of a small infant with Treacher Collins Syndrome using the technique described by Ellis et al. An one month-old infant with Treacher Collins Syndrome was scheduled for mandibular surgery under general endotracheal anesthesia. Direct laryngoscopy for oral intubation failed to reveal the glottis. Fiberoptic intubation using nasal approach and using oral approach through a 1.5 size laryngeal mask airway were performed; however, both approach failed because the fiberscope loaded with a one 3.5mm ID uncuffed tube was stuck inside the nasal cavity or inside the laryngeal mask airway respectively. Therefore, the laryngeal mask airway was keep in place and the fiberoptic intubation technique described by Ellis et al. was planned: the tracheal tube with the 15mm adapter removed was loaded proximally over the fiberscope; the fiberscope was advanced under video-screen visualization into the trachea; the laryngeal mask airway was removed, leaving the fiberscope in place; the tracheal tube was passed completely through the laryngeal mask airway and advanced down over the fiberscope into the trachea; the fiberscope was removed and the 15mm adapter was reattached to the tracheal tube. The fiberoptic intubation method through a laryngeal mask airway described by Ellis et al. can be successfully used in small infants with Treacher Collins Syndrome. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  19. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults†

    PubMed Central

    Frerk, C.; Mitchell, V. S.; McNarry, A. F.; Mendonca, C.; Bhagrath, R.; Patel, A.; O'Sullivan, E. P.; Woodall, N. M.; Ahmad, I.

    2015-01-01

    These guidelines provide a strategy to manage unanticipated difficulty with tracheal intubation. They are founded on published evidence. Where evidence is lacking, they have been directed by feedback from members of the Difficult Airway Society and based on expert opinion. These guidelines have been informed by advances in the understanding of crisis management; they emphasize the recognition and declaration of difficulty during airway management. A simplified, single algorithm now covers unanticipated difficulties in both routine intubation and rapid sequence induction. Planning for failed intubation should form part of the pre-induction briefing, particularly for urgent surgery. Emphasis is placed on assessment, preparation, positioning, preoxygenation, maintenance of oxygenation, and minimizing trauma from airway interventions. It is recommended that the number of airway interventions are limited, and blind techniques using a bougie or through supraglottic airway devices have been superseded by video- or fibre-optically guided intubation. If tracheal intubation fails, supraglottic airway devices are recommended to provide a route for oxygenation while reviewing how to proceed. Second-generation devices have advantages and are recommended. When both tracheal intubation and supraglottic airway device insertion have failed, waking the patient is the default option. If at this stage, face-mask oxygenation is impossible in the presence of muscle relaxation, cricothyroidotomy should follow immediately. Scalpel cricothyroidotomy is recommended as the preferred rescue technique and should be practised by all anaesthetists. The plans outlined are designed to be simple and easy to follow. They should be regularly rehearsed and made familiar to the whole theatre team. PMID:26556848

  20. Predictors of Silicone Tube Intubation Success in Patients with Lacrimal Drainage System Stenosis.

    PubMed

    Baek, Ji Sun; Lee, Saem; Lee, Jung Hye; Choi, Hye Sun; Jang, Jae Woo; Kim, Sung Joo

    2016-06-01

    To evaluate prognostic factors affecting silicone tube intubation outcomes in Asian patients with lacrimal drainage system stenosis. A retrospective review was conducted on the medical records of 822 patients (1,118 eyes) who had undergone silicone tube intubation to treat lacrimal drainage system stenosis between January 2011 and December 2012. Patients were divided into two groups: a success group and a failure group. Success was defined as the disappearance of epiphora symptoms, normalization of tear meniscus height, and the easy passage of fluid without resistance on the postoperative syringing test. Patient and ocular parameters were compared between the success and failure groups. A total of 994 eyes of 727 patients were included in analyses. Patients had a mean follow-up period of 34.11 ± 18.70 weeks. Silicone tube intubation was successful in 67.2% of participants. Significant differences between the success and failure groups were found for age (p < 0.001), history of ipsilateral facial palsy (p = 0.028), follow-up period (p < 0.001), and degree of passage on the preoperative syringing test (p = 0.001). Only age (p < 0.001) and degree of passage on the preoperative syringing test (p = 0.002) remained significantly associated with silicone tube intubation success in multivariate analysis. Age was negatively associated with silicone tube intubation success in patients with lacrimal drainage system stenosis. The success rate was higher in patients who showed easy passage of fluid without resistance on the preoperative syringing test. These factors should be considered by surgeons planning silicone tube intubation in patients with lacrimal drainage system stenosis.

  1. A Randomized Controlled Trial of a CPR and Intubation Video Decision Support Tool for Hospitalized Patients.

    PubMed

    El-Jawahri, Areej; Mitchell, Susan L; Paasche-Orlow, Michael K; Temel, Jennifer S; Jackson, Vicki A; Rutledge, Renee R; Parikh, Mihir; Davis, Aretha D; Gillick, Muriel R; Barry, Michael J; Lopez, Lenny; Walker-Corkery, Elizabeth S; Chang, Yuchiao; Finn, Kathleen; Coley, Christopher; Volandes, Angelo E

    2015-08-01

    Decisions about cardiopulmonary resuscitation (CPR) and intubation are a core part of advance care planning, particularly for seriously ill hospitalized patients. However, these discussions are often avoided. We aimed to examine the impact of a video decision tool for CPR and intubation on patients' choices, knowledge, medical orders, and discussions with providers. This was a prospective randomized trial conducted between 9 March 2011 and 1 June 2013 on the internal medicine services at two hospitals in Boston. One hundred and fifty seriously ill hospitalized patients over the age of 60 with an advanced illness and a prognosis of 1 year or less were included. Mean age was 76 and 51% were women. Three-minute video describing CPR and intubation plus verbal communication of participants' preferences to their physicians (intervention) (N = 75) or control arm (usual care) (N = 75). The primary outcome was participants' preferences for CPR and intubation (immediately after viewing the video in the intervention arm). Secondary outcomes included: orders to withhold CPR/intubation, documented discussions with providers during hospitalization, and participants' knowledge of CPR/ intubation (five-item test, range 0-5, higher scores indicate greater knowledge). Intervention participants (vs. controls) were more likely not to want CPR (64% vs. 32%, p <0.0001) and intubation (72% vs. 43%, p < 0.0001). Intervention participants (vs. controls) were also more likely to have orders to withhold CPR (57% vs. 19%, p < 0.0001) and intubation (64% vs.19%, p < 0.0001) by hospital discharge, documented discussions about their preferences (81% vs. 43%, p < 0.0001), and higher mean knowledge scores (4.11 vs. 2.45; p < 0.0001). Seriously ill patients who viewed a video about CPR and intubation were more likely not to want these treatments, be better informed about their options, have orders to forgo CPR/ intubation, and discuss preferences with providers

  2. Comparison of Macintosh and Intubrite laryngoscopes for intubation performed by novice physicians in a difficult airway scenario.

    PubMed

    Szarpak, Lukasz; Smereka, Jacek; Ladny, Jerzy R

    2017-05-01

    In the difficult airway, the intubation skills are critically important. In selected cases, particularly in airway edema, laryngeal or tongue edema, endotracheal intubation can turn out very difficult, and repeated attempts may even worsen the airway edema, causing trauma and bleeding, and finally leading to complete airway obstruction and inability to ventilate the patient. The aim of the study was to compare the efficacy of endotracheal intubation performed by novice physicians using a standard Macintosh laryngoscope and an Intubrite videolaryngoscope. The study was designed as a prospective, randomized, crossover, simulation study and continues our research assessing the effectiveness of selected endotracheal intubation techniques in prehospital settings. All participants were experienced with the Macintosh direct laryngoscope but remained novice to videolaryngoscopy. Instructions on the correct use of the Macintosh and Intubrite laryngoscopes were given before the procedure, and all the 30 novice physicians were allowed to practice at least 10 times before the study on manikin with normal airways. We employed an airway manikin (Trucorp Airsim Bronchi; Trucorp Ltd., Belfast, Northern Ireland) to simulate difficult airway, with was obtained by inflating the tongue with 50mL of air. The participants were asked to perform tracheal intubation using an endotracheal tube with 7.5mm of internal diameter (Portex; Smiths Medical, Hythe, UK) through the vocal cords, applying either a conventional Macintosh laryngoscope with a size 3 blade (MAC; Mercury Medical, Clearwater, FL, USA) or the Intubrite videolaryngoscope, also with a Macintosh No. 3 blade (INT; Intubrite Llc, Vista, CA, USA). In both intubation techniques, a guide stylet (Rusch Inc., Duluth, GA, USA) was introduced into the endotracheal tube in order to obtain a C-shape curve to facilitate tracheal intubation. Each participating physician was randomly assigned to three attempts of tracheal intubation with each

  3. [Comparison between VAMA(®) and Berman(®) cannulas for fibroscopic orotracheal intubation in anaesthetised patients].

    PubMed

    Castañeda Pascual, M; Batllori Gastón, M; Unzué Rico, P; Murillo Jaso, E; Dorronsoro Auzmendi, M; Martín Vizcaíno, M P

    2013-03-01

    In fibroscopic intubation, the fact of achieving a direct view in real time does not guarantee the correct advance of the endotracheal tube (ET) to its intratracheal position. The use of oral cannulas helps in achieving a free airway in order to pass the fibroscope and the ET. This study compares the VAMA(®) (V) and Berman(®) (B) cannulas as regards the time required for the intubation, fibroscopic view, and the ease in positioning the ET. 90 patients with no signs of difficult airway were randomised into 2 groups, Berman(®) (B) and VAMA(®) (V), depending on the type of cannula employed. After inducing general anaesthesia, they were intubated using a flexible fibroscope. The fibroscope and intubation times were recorded, as well as the quality of the fibroscopic view, and the level of difficulty in positioning the ET. No statistically significant differences were observed between the cannulas, although the intubation time (P=.292) and the difficulty found in positioning the ET were slightly less (P=.447) in the VAMA(®) group compared to the Berman(®) group. The vision quality was good with both devices, with only some degree of obstruction being encountered in only 22% of the patients. In no case was there complete obstruction, thus all the patients could be intubated correctly. The VAMA(®) cannula is an effective alternative to the classic cannulas for fibreoptic assisted intubation. Furthermore, the novel design provides advantages for the correct orientation of the fiberscope and the withdrawal of the cannula after intubation. Copyright © 2011 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  4. Duct having oscillatory side wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sprouse, Kenneth M.

    A pump system includes a particulate consolidator pump that has a pump outlet. A duct is coupled to the pump outlet. The duct has a wall that is coupled with an oscillator. The oscillator is operable to oscillate the wall at a controlled frequency. The controlled frequency is selected with respect to breaking static bridging of particulate in the duct due, at least in part, to consolidation of the particulate from a downstream check valve.

  5. Retrograde intubation: an alternative way for the management of difficult airway.

    PubMed

    Lama, P; Shrestha, B R

    2008-01-01

    Inserting a retrograde wire into the pharynx through a cricothyroid puncture can facilitate tracheal intubation in difficult situations where either a flexible fiber-optic bronchoscope or an expert user of such a device is not available. Even in cases when fibropric can not be negotiated for the purpose, this method has been claimed to be useful to manage the airway. Some mouth opening is essential for the oral or nasal retrieval of the wire from the pharynx. Here, a case of post mandibular reconstructed wound infection required surgical debridement and plate removal from reconstructed lower mandible under general anesthesia. We retrieved the guide wire passed through a cricothyroid puncture and subsequently accomplished wire-guided oro-tracheal intubation. In the absence of a flexible fiber-optic bronchoscope, this technique is a very useful aid to intubate patients with limited mouth opening.

  6. Middle finger length-based tracheal intubation depth improves the rate of appropriate tube placement in children.

    PubMed

    Zhou, Qing-he; Xiao, Wang-pin; Zhou, Hong-mei

    2015-11-01

    It is challenging for anesthetists to determine the optimal tracheal intubation depth in children. We hypothesize that a measure three times the length of the middle finger can be used for predicting tracheal tube depth in children. Eighty-six children (4-14 years of age) were included in this study. After the children were anesthetized, a fiberoptic bronchoscope (FOB) was inserted into the trachea, the lengths from the upper incisor teeth to carina and vocal cords were measured, and a suitably sized cuffed tracheal tube was inserted into the trachea. Age-based and middle finger length-based formulas were used to determine the tracheal intubation depth. All 86 children enrolled were included in this study. Compared with the age-based intubation, the rate of appropriate tube placement was higher for middle finger length-based intubation (88.37% vs 66.28%, P = 0.001). The proximal intubation rate was lower in middle finger length-based intubation (4.65% vs 32.56%, P < 0.001). There was only weak evidence for a difference in the distal intubation rate between the two methods (6.97% vs 1.16%, P = 0.054). The correlation coefficient between middle finger length and optimal tracheal tube depth was larger than that between age and optimal tracheal tube depth (0.883 vs 0.845). Our data indicate that the appropriate tube placement rate can be improved by using three times the middle finger length as the tracheal intubation depth in children. © 2015 John Wiley & Sons Ltd.

  7. Comparison of rocuronium at two different doses and succinylcholine for endotracheal intubation in adult patients for elective surgeries.

    PubMed

    Chavan, S G; Gangadharan, S; Gopakumar, A K

    2016-01-01

    The effects of rocuronium at two different doses, that is, 0.6 mg/kg (2 × ED95) and 0.9 mg/kg (3 × ED95), were compared with succinylcholine (2 mg/kg) when used for endotracheal intubation in adult patients for elective surgeries under general anesthesia. Ninety patients were divided into three groups of 30 each. Groups A, B received injection rocuronium at 0.6 mg/kg, 0.9 mg/kg respectively and Group C received succinylcholine at 2 mg/kg. Onset of action of relaxant, intubation conditions, time taken to intubate and duration of action were compared. To compare the statistical difference in the age, weight, height of the study subjects, onset of action of relaxant, intubation conditions, time taken to intubate, and duration of action analysis of variance and unpaired t -test were used. The onset time was considerably shorter with rocuronium 0.9 mg/kg than 0.6 mg/kg. The onset time of rocuronium 0.9 mg/kg was found to be significantly longer than succinylcholine 2 mg/kg. Time taken to intubate was shortest with succinylcholine 2 mg/kg. The time taken to intubate with the rocuronium 0.9 mg/kg was found to be comparable to that of rocuronium 0.6 mg/kg. Intubation score of rocuronium 0.9 mg/kg was the best (17.75), which was comparable with succinylcholine. However, the intubation score obtained with rocuronium 0.6 mg/kg was inferior. Duration of action was shortest with succinylcholine. The duration of action is prolonged when the dose of rocuronium is increased from 0.6 to 0.9 mg/kg. Rapid sequence induction of anesthesia with propofol and fentanyl, succinylcholine allowed a more rapid endotracheal intubation sequence and created superior intubation conditions than rocuronium. However, the technique of using a large dose of rocuronium to achieve perfect conditions for tracheal intubation may have application whenever succinylcholine is relatively contraindicated.

  8. NewB for newbies: a randomized control trial training housestaff to perform neonatal intubation with direct and videolaryngoscopy.

    PubMed

    Koele-Schmidt, Lindsey; Vasquez, Margarita M

    2016-04-01

    Competency rates in neonatal intubation among pediatric residents are low and currently not meeting ACGME/AAP standards. The aim of this study was to compare standard bedside teaching of neonatal endotracheal intubation to a computer module, as well as introduce residents to the emerging technology of videolaryngoscopy. The study population consisted of The University of Texas Health Science Center at San Antonio Pediatric interns/residents and PGY-1 Anesthesia interns rotating through the NICU. Prior to participating in the study, the residents completed a survey addressing past experiences with intubation, comfort level, and prior use of direct and videolaryngoscopy. Participants then performed timed trials of both direct and videolaryngoscopy on the SimNewB(®). They had up to three attempts to successfully intubate, with up to 30 s on each attempt. After randomization, participants received one of the following teaching interventions: standard, computer module, or both. This was followed by a second intubation trial and survey completion. Thirty residents were enrolled in the study. There was significant improvement in time to successful intubation in both methods after any teaching intervention (direct 22.0 ± 13.4 s vs 14.7 ± 5.9 s, P = 0.002 and videolaryngoscopy 42.2 ± 29.3 s vs 26.8 ± 18.6 s, P = 0.003). No differences were found between the types of teaching. Residents were faster at intubating with direct laryngoscopy compared to videolaryngoscopy before and after teaching. By the end of the study, only 33% of residents preferred using videolaryngoscopy over direct laryngoscopy, but 76% felt videolaryngoscopy was better to teach intubation. Both standard teaching and computer module teaching of neonatal intubation on a mannequin model results in improved time to successful intubation and overall improved resident confidence with intubation equipment and technique. Although intubation times were lower with direct laryngoscopy compared to

  9. Comparison of the Laryngeal View during Tracheal Intubation Using Airtraq and Macintosh Laryngoscopes by Unskillful Anesthesiology Residents: A Clinical Study

    PubMed Central

    Ferrando, Carlos; Aguilar, Gerardo; Belda, F. Javier

    2011-01-01

    Background and Objective. The Airtraq laryngoscope (Prodol Meditec, Vizcaya, Spain) is a novel tracheal intubation device. Studies, performed until now, have compared the Airtraq with the Macintosh laryngoscope, concluding that it reduces the intubation times and increase the success rate at first intubation attempt, decreasing the Cormack-Lehane score. The aim of the study was to evaluate if, in unskillful anesthesiology residents during the laryngoscopy, the Airtraq compared with the Macintosh laryngoscope improves the laryngeal view, decreasing the Cormack-Lehane score. Methods. A prospective, randomized, crossed-over trial was carried out on 60 patients. Each one of the patients were intubated using both devices by unskillful (less than two hundred intubations with the Macintosh laryngoscope and 10 intubations using the Airtraq) anesthesiology residents. The Cormack-Lehane score, the success rate at first intubation attempt, and the laryngoscopy and intubation times were compared. Results. The Airtraq significantly decreased the Cormack-Lehane score (P = 0.04). On the other hand, there were no differences in times of laryngoscopy (P = 0.645; IC 95% 3.1, +4.8) and intubation (P = 0.62; C95%  −6.1, +10.0) between the two devices. No relevant complications were found during the maneuvers of intubation using both devices. Conclusions. The Airtraq is a useful laryngoscope in unskillful anesthesiology residents improving the laryngeal view and, therefore, facilitating the tracheal intubation. PMID:22162683

  10. A new composite measure of colonoscopy: the Performance Indicator of Colonic Intubation (PICI).

    PubMed

    Valori, Roland M; Damery, Sarah; Gavin, Daniel R; Anderson, John T; Donnelly, Mark T; Williams, J Graham; Swarbrick, Edwin T

    2018-01-01

     Cecal intubation rate (CIR) is an established performance indicator of colonoscopy. In some patients, cecal intubation with acceptable tolerance is only achieved with additional sedation. This study proposes a composite Performance Indicator of Colonic Intubation (PICI), which combines CIR, comfort, and sedation. METHODS : Data from 20 085 colonoscopies reported in the 2011 UK national audit were analyzed. PICI was defined as the percentage of procedures achieving cecal intubation with median dose (2 mg) of midazolam or less, and nurse-assessed comfort score of 1 - 3/5. Multivariate logistic regression analysis evaluated possible associations between PICI and patient, unit, colonoscopist, and diagnostic factors. RESULTS : PICI was achieved in 54.1 % of procedures. PICI identified factors affecting performance more frequently than single measures such as CIR and polyp detection, or CIR + comfort alone. Older age, male sex, adequate bowel preparation, and a positive fecal occult blood test as indication were associated with a higher PICI. Unit accreditation, the presence of magnetic imagers in the unit, greater annual volume, fewer years' experience, and higher training/trainer status were associated with higher PICI rates. Procedures in which PICI was achieved were associated with significantly higher polyp detection rates than when PICI was not achieved. CONCLUSIONS : PICI provides a simpler picture of performance of colonoscopic intubation than separate measures of CIR, comfort, and sedation. It is associated with more factors that are amenable to change that might improve performance and with higher likelihood of polyp detection. It is proposed that PICI becomes the key performance indicator for intubation of the colon in colonoscopy quality improvement initiatives. © Georg Thieme Verlag KG Stuttgart · New York.

  11. [Late stage stenoses of bile ducts after iatrogenic bile duct injuries following cholecystectomy].

    PubMed

    Bektas, H; Winny, M; Schrem, H; Becker, T; Klempnauer, J

    2007-12-01

    Iatrogenic bile duct injuries represent a severe complication after cholecystectomy. For the attending physician therapy and management of these injuries are a challenge. Inadequate and delayed treatment can lead to stenoses at a late stage, which can necessitate further surgical intervention. In a study data of 74 patients, who were treated in our clinic for bile duct injuries following cholecystectomy, were analysed retrospectively. A total of 8 patients with late stage bile duct strictures following iatrogenic bile duct injury including the subsequent therapy could be identified. The data of these patients were analysed in respect of cause and strategies to prevent late stage stenoses. In 62 patients the bile duct injury occurred following laparoscopic and in 12 patients following open cholecystectomy. In 16 patients the injury was combined with a vascular lesion. The interval between primary intervention and definitive therapy was 11 days in 53 patients and 1-15 years in 21 patients. In 8 patients the reason for the re-operation after a long interval (1-15 years) was a late stage stenosis. A hepatico-jejunostomy was performed subsequently and during follow-up 5 / 8 patients were symptom-free; 7 patients were re-operated due to a stenosed primary biliodigestive anastomosis and 3 patients each due to atrophy of the right liver lobe and recurrent cholangitis. One patient complained of recurrent cholangitis and a further patient of symptoms due to adhesions. If treated inadequately bile duct injuries occurring during cholecystectomy can in the long-term lead to considerable problems such as recurrent cholangitis, late stage stenoses and even to secondary biliary cirrhosis. Therefore, a complex inter-disciplinary therapeutic concept aiming at timely treatment is necessary.

  12. Use of video-assisted intubation devices in the management of patients with trauma.

    PubMed

    Aziz, Michael

    2013-03-01

    Patients with trauma may have airways that are difficult to manage. Patients with blunt trauma are at increased risk of unrecognized cervical spine injury, especially patients with head trauma. Manual in-line stabilization reduces cervical motion and should be applied whenever a cervical collar is removed. All airway interventions cause some degree of cervical spine motion. Flexible fiberoptic intubation causes the least cervical motion of all intubation approaches, and rigid video laryngoscopy provides a good laryngeal view and eases intubation difficulty. In emergency medicine departments, video laryngoscopy use is growing and observational data suggest an improved success rate compared with direct laryngoscopy. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. A Prospective Observational Study of Technical Difficulty With GlideScope-Guided Tracheal Intubation in Children.

    PubMed

    Zhang, Bin; Gurnaney, Harshad G; Stricker, Paul A; Galvez, Jorge A; Isserman, Rebecca S; Fiadjoe, John E

    2018-05-09

    The GlideScope Cobalt is one of the most commonly used videolaryngoscopes in pediatric anesthesia. Although visualization of the airway may be superior to direct laryngoscopy, users need to learn a new indirect way to insert the tracheal tube. Learning this indirect approach requires focused practice and instruction. Identifying the specific points during tube placement, during which clinicians struggle, would help with targeted education. We conducted this prospective observational study to determine the incidence and location of technical difficulties using the GlideScope, the success rates of various corrective maneuvers used, and the impact of technical difficulty on success rate. We conducted this observational study at our quaternary pediatric hospital between February 2014 and August 2014. We observed 200 GlideScope-guided intubations and documented key intubation-related outcomes. Inclusion criteria for patients were <6 years of age and elective surgery requiring endotracheal intubation. We documented the number of advancement maneuvers required to intubate the trachea, the location where technical difficulty occurred, the types of maneuvers used to address difficulties, and the tracheal intubation success rate. We used a bias-corrected bootstrapping method with 300 replicates to determine the 95% confidence interval (CI) around the rate of difficulty with an intubation attempt. After excluding attempts by inexperienced clinicians, there were 225 attempts in 187 patients, 58% (131 of 225; bootstrap CI, 51.6%-64.6%]) of the attempts had technical difficulties. Technical difficulty was most likely to occur when inserting the tracheal tube between the plane of the arytenoid cartilages to just beyond the vocal cords: "zone 3." Clockwise rotation of the tube was the most common successful corrective maneuver in zone 3. The overall tracheal intubation success rate was 98% (CI, 95%-99%); however, the first attempt success rate was only 80% (CI, 74%-86%). Patients

  14. Awake Fibreoptic Intubation for Forearm Injury in a Patient with Occipito-Cervical Fixator

    PubMed Central

    Akkaya, Akcan; Yıldız, İsa; Demirhan, Abdullah; Tekelioğlu, Ümit Yaşar; Koçoğlu, Hasan

    2013-01-01

    A 23-year-old male patient with occipitocervical fixator was scheduled for surgery due to injury to the right forearm. The patient’s thyromental distance was 5 cm, mouth opening grade II, sternomental distance 10 cm and Mallampati score 4. Loss of extension and rotation movements of the head was assessed as difficult intubation criteria. Anaesthetic procedures are almost always difficult in patients with occipitocervical fixation; the limited cervical extension complicated both intubation and ventilation. In this report, application of general anaesthesia using awake fibreoptic bronchoscopic intubation (FOB) is described. After routine monitoring of vital signs and premedication, hypopharyngeal topical anaesthesia was accomplished by instilling 10% lidocaine spray twice via the appropriate nostril. Superior laryngeal nerve block was performed with local anaesthetic infiltration of tissues 1 cm below the greater horns of the hyoid bone. Lingual and pharyngeal branches of the glossopharyngeal nerve were blocked. Transtracheal block was performed. Following completion of local anaesthesia, the patient was intubated using the awake FOB technique, on 5 L min−1 of 100% O2. After muscle relaxation, the patient underwent a microsurgical operation to repair eight tendons, one artery, and one nerve. Surgery lasted for 5 hours. When the extubation criteria were met, the patient was extubated. In cases of occipitocervical fixation, which causes severe limitation of neck movements, the use of awake fibreoptic intubation should be considered. PMID:27366367

  15. A Plug-and-Play Duct System Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beach, Robert; Dickson, Bruce; Grisolia, Anthony

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less

  16. A Plug-and-Play Duct System Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beach, R.; Dickson, B.; Grisolia, A.

    2017-07-01

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less

  17. Non-intubated uniportal left-lower lobe upper segmentectomy (S6)

    PubMed Central

    Navarro-Martinez, Jose; Bolufer, Sergio; Sesma, Julio; Lirio, Francisco; Galiana, Maria; Rivera, Maria Jesus

    2017-01-01

    Worldwide accepted indications of anatomical segmentectomies are mainly early stage primary adenocarcinomas, pulmonary metastasis and benign conditions. Their performance through uniportal VATS has become more and more popular due to the less invasiveness of the whole procedure under this approach. Recently, many efforts have focused on non-intubated spontaneously breathing management of lobectomies and anatomical segmentectomies, although specific selection criteria and main advantages are not completely standardized. In a 62-year-old thin man with two pulmonary residual metastasis from sigma adenocarcinoma, after chemotherapy plus antiangiogenic treatment, we indicated a single-incision video-assisted left-lower lobe (LLL) upper segmentectomy (S6) under spontaneous breathing and intercostal blockade. Total operation time was 240 minutes. Chest tube was removed at 24 hours and the patient was discharge on postoperative day 2 without any complication. Non-intubated uniportal VATS is a safe and reasonable approach for lung-sparing resections in selected patients, although more evidence is required for selecting which patients can benefit more over standard intubated procedures. PMID:29078611

  18. Lightweight Forms for Epoxy/Aramid Ducts

    NASA Technical Reports Server (NTRS)

    Mix, E. W.; Anderson, A. N.; Bedford, Donald L., Sr.

    1986-01-01

    Aluminum mandrels easy to remove. Lightweight aluminum mandrel for shaping epoxy/aramid ducts simplifies and speeds production. In new process, glass-reinforced epoxy/aramid cloth wrapped on aluminum mandrel. Stainless-steel flanges and other hardware fitted on duct and held by simple tooling. Entire assembly placed in oven to cure epoxy. After curing, assembly placed in alkaline bath dissolves aluminum mandrel in about 4 hours. Epoxy/aramid shell ready for use as duct. Aluminum mandrel used to make ducts of various inside diameters up to 6 in. Standard aluminum forms used. Conventional tube-bending equipment produces requisite curves in mandrels.

  19. Routine antibiotic cover for newborns intubated for aspirating meconium: is it necessary?

    PubMed

    Krishnan, L; Nasruddin; Prabhakar, P; Bhaskaranand, N

    1995-05-01

    A retrospective analysis was performed on 215 babies to evaluate the incidence of septicemia in babies intubated at birth for aspirating meconium from the trachea. Only term, appropriate for gestational age babies were included. Babies with any known perinatal risk factor for infection were excluded from the study and none of the babies had been put on "prophylactic antibiotics." There were 88 babies in the intubated group in a one year period from January 1991 to December 1991. One hundred and twenty seven babies were taken as controls. There was no significant difference in the incidence of early septicemia in the two groups. There were no deaths in either group. It is concluded that well term babies who are intubated for aspirating meconium need not be put on routine antibiotic cover.

  20. Comparison of Oral and Axillary Temperatures in Intubated Pediatric Patients.

    PubMed

    Wood, Danielle; Heitschmidt, Mary; Fogg, Louis

    2018-05-10

    Accurate body temperature measurement is essential in providing timely care to critically ill patients. Current practice within the Pediatric ICU (PICU) at a Midwestern academic medical center is to obtain axillary temperatures in endotracheally intubated patients. According to research, axillary temperatures have greater variance than other forms of temperature measurement. Research in adult patients show that oral temperature measurement in endotracheally intubated patients is acceptable as the heated gases from the ventilator has no significant effect on measured temperatures. This study sought to determine if the same is true in pediatrics. Oral and axillary temperatures of endotracheally intubated pediatric patients were obtained during unit prescribed vital assessment intervals. Patients were divided into neonate, infant, and children age groups with 25 sets of temperatures obtained for each group. Descriptive statistics and Bland-Altman plot interpretation were performed to determine confidence intervals for each age group. Bland-Altman plot analysis of oral and axillary routes of temperature measurement showed a high positive correlation within all age groups studied. The infant age group showed lower correlation in comparison to neonates and children. The infant age group also had an outlier of data sets with lower oral temperatures as compared to the axilla. Oral temperature measurement is a viable alternative to axillary temperature measurement in endotracheally intubated pediatric patients. Correction factors for age groups were calculated for prediction of axillary temperature based on measured oral temperature. This study serves as evidence for practice change within the studied unit. Copyright © 2018. Published by Elsevier Inc.

  1. Estimating 'lost heart beats' rather than reductions in heart rate during the intubation of critically-ill children.

    PubMed

    Jones, Peter; Ovenden, Nick; Dauger, Stéphane; Peters, Mark J

    2014-01-01

    Reductions in heart rate occur frequently in children during critical care intubation and are currently considered the gold standard for haemodynamic instability. Our objective was to estimate loss of heart beats during intubation and compare this to reduction in heart rate alone whilst testing the impact of atropine pre-medication. Data were extracted from a prospective 2-year cohort study of intubation ECGs from critically ill children in PICU/Paediatric Transport. A three step algorithm was established to exclude variation in pre-intubation heart rate (using a 95%CI limit derived from pre-intubation heart rate variation of the children included), measure the heart rate over time and finally the estimate the numbers of lost beats. 333 intubations in children were eligible for inclusion of which 245 were available for analysis (74%). Intubations where the fall in heart rate was less than 50 bpm were accompanied almost exclusively by less than 25 lost beats (n = 175, median 0 [0-1]). When there was a reduction of >50 bpm there was a poor correlation with numbers of lost beats (n = 70, median 42 [15-83]). During intubation the median number of lost beats was 8 [1]-[32] when atropine was not used compared to 0 [0-0] when atropine was used (p<0.001). A reduction in heart rate during intubation of <50 bpm reliably predicted a minimal loss of beats. When the reduction in heart rate was >50 bpm the heart rate was poorly predictive of lost beats. A study looking at the relationship between lost beats and cardiac output needs to be performed. Atropine reduces both fall in heart rate and loss of beats. Similar area-under-the-curve methodology may be useful for estimating risk when biological parameters deviate outside normal range.

  2. Tear-Duct Obstruction and Surgery

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Tear-Duct Obstruction and Surgery KidsHealth / For Parents / Tear- ... year old with little or no treatment. About Tear Ducts Our eyes are continually exposed to dust, ...

  3. Tracheal intubation using Macintosh and 2 video laryngoscopes with and without chest compressions.

    PubMed

    Kim, Young-Min; Kim, Ji-Hoon; Kang, Hyung-Goo; Chung, Hyun Soo; Yim, Hyeon-Woo; Jeong, Seung-Hee

    2011-07-01

    The aim of the study was to compare the time taken for intubation (TTI) using the Macintosh and 2 video laryngoscopes (VLs) (GlideScope [GVL]; Saturn Biomedical System, Burnaby, British Columbia, Canada, and Airway Scope [AWS]; Pentax, Tokyo, Japan) with and without chest compressions by experienced intubators in a mannequin model. This was a randomized crossover study. Twenty-two experienced physicians who have limited experience in the VLs participated in the study. The TTI using 3 laryngoscopes with and without compressions were compared. Median TTI difference between 2 conditions was only significant in the AWS (1.64 seconds; P = .01). There were no significant differences in the TTI between the Macintosh and the GVL or the AWS during compressions. In a mannequin model, the Macintosh or the GVL was not affected by chest compressions. The TTI using the AWS was delayed by compressions but not clinically significant. Considering the lack of experience, 2 VLs may be useful adjuncts for intubation by experienced intubators during chest compressions. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Electromagnetic propagation in PEC and absorbing curved S-ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1988-01-01

    A finite-element Galerkin formulation has been developed to study transverse magnetic (TM) wave propagation in 2-D S-curved ducts with both perfectly conducting and absorbing walls. The reflection and transmission at the entrances and the exits of the curved ducts are determined by coupling the finite-element solutions in the curved ducts to the eigenfunctions of an infinite, uniform, perfectly conducting duct. Example solutions are presented for a double mitred and S-ducts of various lengths. The length of the S-duct is found to significantly effect the reflective characteristics of the duct. Also, the effect of curvature on an absorbing duct is illustrated.

  5. C-MAC compared with direct laryngoscopy for intubation in patients with cervical spine immobilization: A manikin trial.

    PubMed

    Smereka, Jacek; Ladny, Jerzy R; Naylor, Amanda; Ruetzler, Kurt; Szarpak, Lukasz

    2017-08-01

    The aim of this study was to compare C-MAC videolaryngoscopy with direct laryngoscopy for intubation in simulated cervical spine immobilization conditions. The study was designed as a prospective randomized crossover manikin trial. 70 paramedics with <5years of medical experience participated in the study. The paramedics attempted to intubate manikins in 3 airway scenarios: normal airway without cervical immobilization (Scenario A); manual inline cervical immobilization (Scenario B); cervical immobilization using cervical extraction collar (Scenario C). Scenario A: Nearly all participants performed successful intubations with both MAC and C-MAC on the first attempt (95.7% MAC vs. 100% C-MAC), with similar intubation times (16.5s MAC vs. 18s C-MAC). Scenario B: The results with C-MAC were significantly better than those with MAC (p<0.05) for the time of intubation (23 s MAC vs. 19 s C-MAC), success of the first intubation attempt (88.6% MAC vs. 100% C-MAC), Cormack-Lehane grade, POGO score, severity of dental compression, device difficulty score, and preferred airway device. Scenario C: The results with C-MAC were significantly better than those with MAC (p<0.05) for all the analysed variables: success of the first attempt (51.4% MAC vs. 100% C-MAC), overall success rate, intubation time (27 s MAC vs. 20.5 s C-MAC), Cormack-Lehane grade, POGO score, dental compression, device difficulty score and the preferred airway device. The C-MAC videolaryngoscope is an excellent alternative to the MAC laryngoscope for intubating manikins with cervical spine immobilization. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beal, D.; McIlvaine , J.; Fonorow, K.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition tomore » enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.« less

  7. Convolution seal for transition duct in turbine system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston

    2015-05-26

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface feature for interfacing with an adjacent transition duct. The turbine system further includes a convolution seal contacting the interface feature to provide a seal between the interface feature andmore » the adjacent transition duct.« less

  8. [Comparison of two shaping methods for double-lumen endotracheal tube intubation by Shikani optical stylet laryngoscope].

    PubMed

    Xu, T; Li, M; Xu, M; Guo, X Y

    2016-12-18

    To compare the efficacy and safety of two different shaping methods for double-lumen endotracheal tube (DLT).DLT was shaped with the rod of a Shikani optical stylet (SOS) with the tracheal orifice aligned with the convex aspect of the distal curvature or the concave aspect of the distal curvature. Patients scheduled for elective thoracic surgery and required intubation with a left-sided DLT were enrolled in this study. They were randomized into two groups. They were intubated with a DLT, which was shaped with the rod of a SOS with its tracheal orifice aligned with the convex aspect of the distal curvature (group T) or the concave aspect of the distal curvature (group U). Time for SOS manipulation, intubation attempts, intubation resistance score, malposition of bronchial intubation, time for fiberoptic bronchoscope (FOB) identification of bronchial placement, total intubation time and oral mucosal or dental injury were recorded. Hoarseness and throat sore of the patients were evaluated 1 hour and 24 hours after surgery. A total of 136 patients completed the study, with 68 in each group. Time for SOS manipulation was significantly shorter in group U [(35.1±6.1) s vs. 39.6±11.8) s, P=0.007]. First attempt success rate did not differ between the groups (92.6% vs.88.2%, P=0.561). Intubation resistance score was significantly lower in group U. Group T had fewer patients who suffered malposition of bronchial intubation than group U (4 vs.13, P=0.020) and cost less time for FOB identification of bronchial placement [(44.1±20.9) s vs.(53.6±29.2) s, P=0.032]. Total intubation time and the incidence of oral mucosal or dental injury did not differ between the groups. The severity and incidence of hoarseness were lower in group U than in group T 1 hour after surgery. The severity and incidence of sore throat were lower in group U than in group T 1 hour and 24 hours postoperatively. When lacing a left-sided DLT using a SOS, shaping the DLT with the tracheal orifice aligned

  9. Financial Aspects of Bile Duct Injuries.

    PubMed

    Palaz Alı, Ozgkıour; Ibis, Abdil Cem; Gurtekin, Basak

    2017-11-04

    BACKGROUND Major bile duct injury is the most worrisome complication of cholecystectomy. There is no detailed data about the incidence or treatment-related costs of bile duct injuries in Turkey. We aimed to determine prevalence and therapeutic costs of patients with major biliary duct injuries managed in our department, and further estimate a projection of these parameters at the national level. MATERIAL AND METHODS All patients admitted due to bile duct injury during cholecystectomy from 2011 to 2014 were included. Healthcare costs were calculated by summing of their all treatment-related costs in Istanbul Medical Faculty. We collected 2014-2015 data on number of patients diagnosed with cholecystitis in Turkey, the number of cholecystectomies, and the number of the interventions performed following these initial surgeries, which were obtained from the Turkish Social Security Institution. RESULTS Forty-nine patients were enrolled and bilioenteric diversion was performed in 39 patients: 20.4% of patients had Bismuth II, 38.8% had Bismuth III, and 40.8% had Bismuth IV biliary stricture. Comparison of stricture types with total costs, days of hospitalization, and outpatient clinic costs revealed significant differences. Mean total cost of corrective surgeries was 9199 TRY. We estimated that 1.5% to 2.4% of patients who underwent cholecystectomy in Turkey have bile duct injury (including 0.3% with major bile duct injury). CONCLUSIONS New preventive strategies should be used to avoid bile duct injuries, which have a huge financial impact on the national economy.

  10. A 12-month descriptive analysis of emergency intubations at Brooke Army Medical Center: a National Emergency Airway Registry study.

    PubMed

    April, Michael D; Schauer, Steven G; Brown Rd, Calvin A; Ng, Patrick C; Fernandez, Jessie; Fantegrossi, Andrea E; Maddry, Joseph K; Summers, Shane; Sessions, Daniel J; Barnwell, Robert M; Antonacci, Mark

    2017-01-01

    Emergency airway management is a critical skill for military healthcare providers. Our goal was to describe the Emergency Department (ED) intubations at Brooke Army Medical Center (BAMC) over a 12-month period. Physicians performing endotracheal intubations in the BAMC ED complete data collection forms for each intubation event as part of the National Emergency Airway Registry, including patient demographics, intubation techniques, success and failure rates, adverse events, and patient disposition. We cross-referenced these forms against the numbers of intubation events reported in the ED nursing daily reports to ensure capture of all intubations. Providers completed forms for every intubation within 6 weeks of the procedure. We analyzed data from March 28, 2016, to March 27, 2017. During the study period, providers performed 259 intubations in the BAMC ED. Reasons for intubation were related to trauma for 184 patients (71.0%) and medical conditions for 75 patients (29.0%). Overall, first-attempt success was 83.0%. Emergency medicine residents performed a majority of first attempts (95.0%). Most common devices chosen on first attempt were a video laryngoscope for 143 patients (55.2%) and a direct laryngoscope for 115 patients (44.4%). One patient underwent cricothyrotomy. The 2 most common induction agents were ketamine (59.8%; 95% CI, 55.2%-67.4%) and etomidate (19.3%; 95% CI, 14.7%-24.7%). The most common neuromuscular blocking agents were rocuronium (62.9%; 95% CI, 56.7%-68.8%) and succinylcholine (18.9%; 95% CI, 14.3%-24.2%). In the BAMC ED, emergency intubation most commonly occurred for trauma indications using video laryngoscopy with a high first-pass success.

  11. Comparison of Preloaded Bougie versus Standard Bougie Technique for Endotracheal Intubation in a Cadaveric Model.

    PubMed

    Baker, Jay B; Maskell, Kevin F; Matlock, Aaron G; Walsh, Ryan M; Skinner, Carl G

    2015-07-01

    We compared intubating with a preloaded bougie (PB) against standard bougie technique in terms of success rates, time to successful intubation and provider preference on a cadaveric airway model. In this prospective, crossover study, healthcare providers intubated a cadaver using the PB technique and the standard bougie technique. Participants were randomly assigned to start with either technique. Following standardized training and practice, procedural success and time for each technique was recorded for each participant. Subsequently, participants were asked to rate their perceived ease of intubation on a visual analogue scale of 1 to 10 (1=difficult and 10=easy) and to select which technique they preferred. 47 participants with variable experience intubating were enrolled at an emergency medicine intern airway course. The success rate of all groups for both techniques was equal (95.7%). The range of times to completion for the standard bougie technique was 16.0-70.2 seconds, with a mean time of 29.7 seconds. The range of times to completion for the PB technique was 15.7-110.9 seconds, with a mean time of 29.4 seconds. There was a non-significant difference of 0.3 seconds (95% confidence interval -2.8 to 3.4 seconds) between the two techniques. Participants rated the relative ease of intubation as 7.3/10 for the standard technique and 7.6/10 for the preloaded technique (p=0.53, 95% confidence interval of the difference -0.97 to 0.50). Thirty of 47 participants subjectively preferred the PB technique (p=0.039). There was no significant difference in success or time to intubation between standard bougie and PB techniques. The majority of participants in this study preferred the PB technique. Until a clear and clinically significant difference is found between these techniques, emergency airway operators should feel confident in using the technique with which they are most comfortable.

  12. Duct Leakage Repeatability Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the twomore » duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.« less

  13. A randomized controlled study to evaluate and compare Truview blade with Macintosh blade for laryngoscopy and intubation under general anesthesia.

    PubMed

    Timanaykar, Ramesh T; Anand, Lakesh K; Palta, Sanjeev

    2011-04-01

    The Truview EVO2™ laryngoscope is a recently introduced device with a unique blade that provides a magnified laryngeal view at 42° anterior reflected view. It facilitates visualization of the glottis without alignment of oral, pharyngeal, and tracheal axes. We compared the view obtained at laryngoscopy, intubating conditions and hemodynamic parameters of Truview with Macintosh blade. In prospective, randomized and controlled manner, 200 patients of ASA I and II of either sex (20-50 years), presenting for surgery requiring tracheal intubation, were assigned to undergo intubation using a Truview or Macintosh laryngoscope. Visualization of the vocal cord, ease of intubation, time taken for intubation, number of attempts, and hemodynamic parameters were evaluated. Truview provided better results for the laryngeal view using Cormack and Lehane grading, particularly in patients with higher airway Mallampati grading (P < 0.05). The time taken for intubation (33.06±5.6 vs. 23.11±57 seconds) was more with Truview than with Macintosh blade (P < 0.01). The Percentage of Glottic Opening (POGO) score was significantly higher (97.26±8) in Truview as that observed with Macintosh blade (83.70±21.5). Hemodynamic parameters increased after tracheal intubation from pre-intubation value (P < 0.05) in both the groups, but they were comparable amongst the groups. No postoperative adverse events were noted. Tracheal intubation using Truview blade provided consistently improved laryngeal view as compared to Macintosh blade without the need to align the oral, pharyngeal and tracheal axes, with equal attempts for successful intubation and similar changes in hemodynamics. However, the time taken for intubation was more with Truview.

  14. A randomized controlled study to evaluate and compare Truview blade with Macintosh blade for laryngoscopy and intubation under general anesthesia

    PubMed Central

    Timanaykar, Ramesh T; Anand, Lakesh K; Palta, Sanjeev

    2011-01-01

    Background: The Truview EVO2™ laryngoscope is a recently introduced device with a unique blade that provides a magnified laryngeal view at 42° anterior reflected view. It facilitates visualization of the glottis without alignment of oral, pharyngeal, and tracheal axes. We compared the view obtained at laryngoscopy, intubating conditions and hemodynamic parameters of Truview with Macintosh blade. Materials and Methods: In prospective, randomized and controlled manner, 200 patients of ASA I and II of either sex (20–50 years), presenting for surgery requiring tracheal intubation, were assigned to undergo intubation using a Truview or Macintosh laryngoscope. Visualization of the vocal cord, ease of intubation, time taken for intubation, number of attempts, and hemodynamic parameters were evaluated. Results: Truview provided better results for the laryngeal view using Cormack and Lehane grading, particularly in patients with higher airway Mallampati grading (P < 0.05). The time taken for intubation (33.06±5.6 vs. 23.11±57 seconds) was more with Truview than with Macintosh blade (P < 0.01). The Percentage of Glottic Opening (POGO) score was significantly higher (97.26±8) in Truview as that observed with Macintosh blade (83.70±21.5). Hemodynamic parameters increased after tracheal intubation from pre-intubation value (P < 0.05) in both the groups, but they were comparable amongst the groups. No postoperative adverse events were noted. Conclusion: Tracheal intubation using Truview blade provided consistently improved laryngeal view as compared to Macintosh blade without the need to align the oral, pharyngeal and tracheal axes, with equal attempts for successful intubation and similar changes in hemodynamics. However, the time taken for intubation was more with Truview. PMID:21772680

  15. Articulated transition duct in turbomachine

    DOEpatents

    Flanagan, James Scott; McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Pentecost, Ronnie Ray

    2014-04-29

    Turbine systems are provided. A turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion and a downstream portion. The upstream portion extends from the inlet between an inlet end and an aft end. The downstream portion extends from the outlet between an outlet end and a head end. The turbine system further includes a joint coupling the aft end of the upstream portion and the head end of the downstream portion together. The joint is configured to allow movement of the upstream portion and the downstream portion relative to each other about or along at least one axis.

  16. Vitellointestinal Duct Anomalies in Infancy.

    PubMed

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5-9 of intrauterine life. This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality.

  17. Proper size of endotracheal tube for cleft lip and palate patients and intubation outcomes.

    PubMed

    Abdollahifakhim, Shahin; Sheikhzadeh, Dariush; Shahidi, Nikzad; Nojavan, Gholamreza; Bayazian, Gholamreza; Aleshi, Hamideh

    2013-05-01

    The aim of the current study was to identify the proper size of endotracheal tube for intubation of cleft lip and palate patients and intubation outcomes in these patients. In this analytic cross-sectional study, 60 nonsyndromic cleft lip and palate patients were selected who had surgery between April 2010 and April 2012 at Pediatrics Hospital, Tabriz University of Medical Sciences, Iran. Demographic findings, previous admissions, and surgical history were registered. The proper tube size was measured by normal children formulas. Then tube size was confirmed by patients' minimum resistance to intubation, proper ventilation reported by anesthesiologist, and appropriate air leakage at an airway pressure of 15-20 cm H₂O. If intubation was unsuccessful then smaller size of endotracheal tube would be tried. Frequency of intubation trials and the biggest endotracheal tube size were recorded. Their average age, weight and height were 21.39 ± 4.95 months, 9.97 ± 1.18 kg and 74.30 ± 26.61 cm, respectively. The average tracheal tube size and frequency of intubation trials were 4.34 ± 0.78 and 1.63 ± 0.80, respectively. Seven cases required an endotracheal tube size smaller than the recommended size for that age including one case in unilateral cleft palate, three cases in unilateral cleft lip, one case in unilateral cleft lip and palate, and two cases in bilateral cleft lip and palate. Findings proved that considering subglottic stenosis incidence in these children, it is reasonable to determine the tube size for nonsyndromic cleft lip and palate patients by applying the currently available standards for normal children. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  18. Training with video imaging improves the initial intubation success rates of paramedic trainees in an operating room setting.

    PubMed

    Levitan, R M; Goldman, T S; Bryan, D A; Shofer, F; Herlich, A

    2001-01-01

    Video imaging of intubation as seen by the laryngoscopist has not been a part of traditional instruction methods, and its potential impact on novice intubation success rates has not been evaluated. We prospectively tracked the success rates of novice intubators in paramedic classes who were required to watch a 26-minute instructional videotape made with a direct laryngoscopy imaging system (video group). We compared the prospectively obtained intubation success rate of the video group against retrospectively collected data from prior classes of paramedic students (traditional group) in the same training program. All classes received the same didactic airway instruction, same mannequin practice time, same paramedic textbook, and were trained in the same operating room with the same teaching staff. The traditional group (n=113, total attempts 783) had a mean individual intubation success rate of 46.7% (95% confidence interval 42.2% to 51.3%). The video group (n=36, total attempts 102) had a mean individual intubation success rate of 88.1% (95% confidence interval 79.6% to 96.5%). The difference in mean intubation success rates between the 2 groups was 41.4% (95% confidence interval 31.1% to 50.7%, P <.0001). The 2 groups did not differ in respect to age, male sex, or level of education. An instructional videotape made with the direct laryngoscopy video system significantly improved the initial success rates of novice intubators in an operating room setting.

  19. Airway Management of Near-Complete Tracheal Transection by Through-the-Wound Intubation: A Case Report.

    PubMed

    Jean, Yuel-Kai; Potnuru, Paul; Diez, Christian

    2018-06-11

    We present an approach to airway management in a patient with machete injuries culminating in near-complete cricotracheal transection, in addition to a gunshot wound to the neck. Initial airway was established by direct intubation through the cricotracheal wound. Once the airway was secured, a bronchoscopy-guided orotracheal intubation was performed with simultaneous retraction of the cricotracheal airway to optimize the surgical field. This case offers insight into a rarely performed approach to airway management. Furthermore, our case report demonstrates that, in select airway injuries, performing through-the-wound intubation engenders a multitude of benefits.

  20. Quality of Vision in Eyes With Epiphora Undergoing Lacrimal Passage Intubation.

    PubMed

    Koh, Shizuka; Inoue, Yasushi; Ochi, Shintaro; Takai, Yoshihiro; Maeda, Naoyuki; Nishida, Kohji

    2017-09-01

    To investigate visual function and optical quality in eyes with epiphora undergoing lacrimal passage intubation. Prospective case series. Thirty-four eyes of 30 patients with lacrimal passage obstruction were enrolled. Before and 1 month after lacrimal passage intubation, functional visual acuity (FVA), higher-order aberrations (HOAs), lower tear meniscus, and tear clearance were assessed. An FVA measurement system was used to examine changes in continuous visual acuity (VA) over time, and visual function parameters such as FVA, visual maintenance ratio, and blink frequency were obtained. Sequential ocular HOAs were measured for 10 seconds after the blink using a wavefront sensor. Aberration data were analyzed in the central 4 mm for coma-like, spherical-like, and total HOAs. Fluctuation and stability indices of the total HOAs over time were calculated. Lower tear meniscus was assessed by anterior segment optical coherence tomography. After lacrimal passage intubation, visual function significantly improved, as indicated by improved FVA (P = .003) and visual maintenance ratio (P < .001). Blink frequency decreased significantly after treatment (P = .01). Optical quality significantly improved, as indicated by a decrease in coma-like aberrations (P = .003), spherical-like aberrations (P = .018), and total HOAs (P = .001). Stability index increased (P < .001) and fluctuation index decreased (P = .019), and tear meniscus dimension decreased (P < .001). Lacrimal passage intubation for eyes with epiphora significantly improved visual function and optical quality via patency of the lacrimal passage. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Fan/Ram Duct Program

    DTIC Science & Technology

    1973-10-01

    turbofan engine shutoff scheme, the ram duct flow conditions, and the Ian duct shutoff vane area transi- tion schedule. This loss will be...airflow. The performance of the turbofan is neglected until the main engine burner is ignited. At that time it is assumed that the turbo - fan...B. Transient Operation . . .. TRANSIENT TRANSITION TEST CASES A. Turbofan to Ramjet B. Ramjet to Turbo fan CONCLUSIONS AND RECOMMENDATIONS

  2. Sound radiation from a flanged inclined duct.

    PubMed

    McAlpine, Alan; Daymond-King, Alex P; Kempton, Andrew J

    2012-12-01

    A simple method to calculate sound radiation from a flanged inclined duct is presented. An inclined annular duct is terminated by a rigid vertical plane. The duct termination is representative of a scarfed exit. The concept of a scarfed duct has been examined in turbofan aero-engines as a means to, potentially, shield a portion of the radiated sound from being transmitted directly to the ground. The sound field inside the annular duct is expressed in terms of spinning modes. Exterior to the duct, the radiated sound field owing to each mode can be expressed in terms of its directivity pattern, which is found by evaluating an appropriate form of Rayleigh's integral. The asymmetry is shown to affect the amplitude of the principal lobe of the directivity pattern, and to alter the proportion of the sound power radiated up or down. The methodology detailed in this article provides a simple engineering approach to investigate the sound radiation for a three-dimensional problem.

  3. The acoustics of ducted propellers

    NASA Astrophysics Data System (ADS)

    Ali, Sherif F.

    The return of the propeller to the long haul commercial service may be rapidly approaching in the form of advanced "prop fans". It is believed that the advanced turboprop will considerably reduce the operational cost. However, such aircraft will come into general use only if their noise levels meet the standards of community acceptability currently applied to existing aircraft. In this work a time-marching boundary-element technique is developed, and used to study the acoustics of ducted propeller. The numerical technique is developed in this work eliminated the inherent instability suffered by conventional approaches. The methodology is validated against other numerical and analytical results. The results show excellent agreement with the analytical solution and show no indication of unstable behavior. For the ducted propeller problem, the propeller is modeled by a rotating source-sink pairs, and the duct is modeled by rigid annular body of elliptical cross-section. Using the model and the developed technique, the effect of different parameters on the acoustic field is predicted and analyzed. This includes the effect of duct length, propeller axial location, and source Mach number. The results of this study show that installing a short duct around the propeller can reduce the noise that reaches an observer on a side line.

  4. A mannequin study of intubation with the AP advance and GlideScope Ranger videolaryngoscopes and the Macintosh laryngoscope.

    PubMed

    Hodd, Jack A R; Doyle, D John; Gupta, Shipra; Dalton, Jarrod E; Cata, Juan P; Brewer, Edward J; James, Monyulona; Sessler, Daniel I

    2011-10-01

    The AP Advance (APA) is a videolaryngoscope with interchangeable blades: intubators can choose standard Macintosh blades or a difficult-airway blade with increased curvature and a channel to guide the tube to the larynx. The APA may therefore be comparably effective in both normal and difficult airways. We tested the hypotheses that intubation with the APA is no slower than Macintosh laryngoscopy for normal mannequin airways, and that it is no slower than videolaryngoscopy using a GlideScope Ranger in difficult mannequin airways. Medical professionals whose roles potentially include tracheal intubation were trained with each device. Participants intubated simulated (Laerdal SimMan) normal and difficult airways with the APA, GlideScope, and a conventional Macintosh blade. Speed of intubation was compared using Cox proportional hazards regression, with a hazard ratio >0.8 considered noninferior. We also compared laryngeal visualization, failures, and participant preferences. Unadjusted intubation times in the normal airway with the APA and Macintosh were virtually identical (median, 22 vs 23 seconds); after adjustment for effects of experience, order, and period, the hazard ratio (95% confidence interval) comparing APA with Macintosh laryngoscopy was 0.87 (0.65, 1.17), which was not significantly more than our predefined noninferiority boundary of 0.8 (P = 0.26). Intubation with the APA was faster than with the GlideScope in difficult airways (hazard ratio = 7.6 [5.0, 11.3], P < 0.001; median, 20 vs 59 seconds). All participants intubated the difficult airway mannequin with the APA, whereas 33% and 37% failed with the GlideScope and Macintosh, respectively. In the difficult airway, 99% of participants achieved a Cormack and Lehane grade I to II view with the APA, versus 85% and 33% with the GlideScope and Macintosh, respectively. When asked to choose 1 device overall, 82% chose the APA. Intubation times were similar with the APA and Macintosh laryngoscopes in

  5. Propagation and radiation of sound from flanged circular ducts with circumferentially varying wall admittances. I Semi-infinite ducts. II - Finite ducts with sources

    NASA Technical Reports Server (NTRS)

    Fuller, C. R.

    1984-01-01

    Sound propagation in infinite, semiinfinite, and finite circular ducts with circumferentially varying wall admittances is investigated analytically. The infinite case is considered, and an example demonstrates the effects of wall-admittance distribution on dispersion characteristics and mode shapes. An exact solution is obtained for the semiinfinite case, a circular duct with a flanged opening: sidelobe suppression and circumferential-mode energy scattering leading to radiated-field asymmetry are found. A finite duct system with specified hard-walled pressure sources is examined in detail, evaluating reflection coefficients, transmission losses, and radiated-field directivity. Graphs and diagrams are provided, and the implications of the results obtained for the design of aircraft-turbofan inlet liners are discussed.

  6. Performance-based comparison of neonatal intubation training outcomes: simulator and live animal.

    PubMed

    Andreatta, Pamela B; Klotz, Jessica J; Dooley-Hash, Suzanne L; Hauptman, Joe G; Biddinger, Bea; House, Joseph B

    2015-02-01

    The purpose of this article was to establish psychometric validity evidence for competency assessment instruments and to evaluate the impact of 2 forms of training on the abilities of clinicians to perform neonatal intubation. To inform the development of assessment instruments, we conducted comprehensive task analyses including each performance domain associated with neonatal intubation. Expert review confirmed content validity. Construct validity was established using the instruments to differentiate between the intubation performance abilities of practitioners (N = 294) with variable experience (novice through expert). Training outcomes were evaluated using a quasi-experimental design to evaluate performance differences between 294 subjects randomly assigned to 1 of 2 training groups. The training intervention followed American Heart Association Pediatric Advanced Life Support and Neonatal Resuscitation Program protocols with hands-on practice using either (1) live feline or (2) simulated feline models. Performance assessment data were captured before and directly following the training. All data were analyzed using analysis of variance with repeated measures and statistical significance set at P < .05. Content validity, reliability, and consistency evidence were established for each assessment instrument. Construct validity for each assessment instrument was supported by significantly higher scores for subjects with greater levels of experience, as compared with those with less experience (P = .000). Overall, subjects performed significantly better in each assessment domain, following the training intervention (P = .000). After controlling for experience level, there were no significant differences among the cognitive, performance, and self-efficacy outcomes between clinicians trained with live animal model or simulator model. Analysis of retention scores showed that simulator trained subjects had significantly higher performance scores after 18 weeks (P = .01

  7. Compact Buried Ducts in a Hot-Humid Climate House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, Dave

    2016-01-07

    "9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely onmore » encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.« less

  8. Effect of rocuronium on the bispectral index under anesthesia and tracheal intubation.

    PubMed

    Yue, Hui; Han, Jinyu; Liu, Ling; Wang, Kaiyuan; Li, Jincheng

    2016-12-01

    The aim of the present study was to investigate the effect of various doses of rocuronium on bispectral index (BIS) responses to propofol induction and tracheal intubation, as well as the role of the non-depolarization muscle relaxant rocuronium on the depth of sedation. A total of 72 patients (American Society of Anesthesiologists physical status I-II) were anaesthetized with propofol using a target-controlled infusion, and randomly divided into two sedation level groups (n=36). The patients were divided into 2 groups according to the BIS value: A normal sedation group (group 1), with a stable BIS value at 40-60, and a deep sedation group (group 2), with a BIS value <20 or with burst suppression. Each group was randomly divided into 4 subgroups A-D (n=9) according to the various doses of rocuronium (0.3, 0.6, 0.9 and 1.2 mg/kg). Tracheal intubation was performed after 2 min of rocuronium administration. BIS, electromyography (EMG), heart rate (HR) and mean arterial pressure (MAP) were recorded continuously and averaged over 1 min during baseline (T1), steady state (T2), 2 min after rocuronium infusion (T3), and 0, 2 and 5 min after tracheal intubation. The results demonstrated that HR and MAP decreased significantly at T2 and T3 compared with T1. Following tracheal intubation (L0), HR and MAP significantly increased compared with T2 and T3, and returned to levels similar to those prior to intubation after 5 min. In group 1C and 1D, BIS was significantly decreased at T3 compared with T2; BIS was significantly increased at L0 compared with T3 in group 1A and 1B. EMG at earlier stages of anesthesia was significantly higher compared with other points, and was significantly increased at L0 compared with T3 in group 1A and 1B. These results demonstrated that BIS response may be associated with the dosage of rocuronium in the normal sedation group, although no association was observed with the deep sedation group. Tracheal intubation resulted in marked hemodynamic

  9. Vitellointestinal Duct Anomalies in Infancy

    PubMed Central

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Background: Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5–9 of intrauterine life. Methods: This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Results: Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Conclusion: Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality. PMID:27433448

  10. Succinylcholine versus rocuronium for rapid sequence intubation in intensive care: a prospective, randomized controlled trial

    PubMed Central

    2011-01-01

    Introduction Succinylcholine and rocuronium are widely used to facilitate rapid sequence induction (RSI) intubation in intensive care. Concerns relate to the side effects of succinylcholine and to slower onset and inferior intubation conditions associated with rocuronium. So far, succinylcholine and rocuronium have not been compared in an adequately powered randomized trial in intensive care. Accordingly, the aim of the present study was to compare the incidence of hypoxemia after rocuronium or succinylcholine in critically ill patients requiring an emergent RSI. Methods This was a prospective randomized controlled single-blind trial conducted from 2006 to 2010 at the University Hospital of Basel. Participants were 401 critically ill patients requiring emergent RSI. Patients were randomized to receive 1 mg/kg succinylcholine or 0.6 mg/kg rocuronium for neuromuscular blockade. The primary outcome was the incidence of oxygen desaturations defined as a decrease in oxygen saturation ≥ 5%, assessed by continuous pulse oxymetry, at any time between the start of the induction sequence and two minutes after the completion of the intubation. A severe oxygen desaturation was defined as a decrease in oxygen saturation ≥ 5% leading to a saturation value of ≤ 80%. Results There was no difference between succinylcholine and rocuronium regarding oxygen desaturations (succinylcholine 73/196; rocuronium 66/195; P = 0.67); severe oxygen desaturations (succinylcholine 20/196; rocuronium 20/195; P = 1.0); and extent of oxygen desaturations (succinylcholine -14 ± 12%; rocuronium -16 ± 13%; P = 0.77). The duration of the intubation sequence was shorter after succinycholine than after rocuronium (81 ± 38 sec versus 95 ± 48 sec; P = 0.002). Intubation conditions (succinylcholine 8.3 ± 0.8; rocuronium 8.2 ± 0.9; P = 0.7) and failed first intubation attempts (succinylcholine 32/200; rocuronium 36/201; P = 1.0) did not differ between the groups. Conclusions In critically ill

  11. Bile duct adenoma and von Meyenburg complex-like duct arising in hepatitis and cirrhosis: pathogenesis and histological characteristics.

    PubMed

    Aishima, Shinichi; Tanaka, Yuki; Kubo, Yuichiro; Shirabe, Ken; Maehara, Yoshihiko; Oda, Yoshinao

    2014-11-01

    Morphologic features and neoplastic potentials of bile duct adenoma (BDA) and von Meyenburg complex (VMC)-like duct arising in chronic liver disease were unknown. Thirty-five BDAs and 12 VMC-like duct lesions were observed in 39 cases with chronic liver disease. BDAs were divided into the EMA-cytoplasmic type (n = 14) and EMA-luminal type (n = 21). EMA-cytoplasmic BDA composed of a proliferation of cuboidal to low-columnar cells forming an open lumen with NCAM(+)/MUC6(-), resembling an interlobular bile duct. EMA-luminal BDA showed uniform cuboidal cells with narrow lumen, and NCAM(++)/MUC6(++), resembling a ductular reaction. VMC-like duct showed positive MUC1 expression and negative MUC6. The expression of S100P, glucose transporter-1 (GLUT-1) and insulin-like growth factor II mRNA-binding protein 3 (IMP-3) were not detected in three lesions. p16 expression was higher than those of the ductular reaction, and the Ki67 and p53 indexes were very low (<1.0%). Large-sized EMA-luminal BDA shows sclerotic stroma. We classified small nodular lesions of ductal or ductular cells in chronic hepatitis and cirrhosis into the following groups: BDA, interlobular bile duct type; BDA, ductular/peribiliary gland type; and VMC-like duct. They may be reactive proliferation rather than neoplastic lesions. © 2014 Japanese Society of Pathology and Wiley Publishing Asia Pty Ltd.

  12. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

    PubMed Central

    Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.

    2010-01-01

    Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641

  13. A comparison of intubation success for paediatric transport team paramedics using lighted vs regular tracheal tube stylets.

    PubMed

    MacNab, A J; MacPhail, I; MacNab, M K; Noble, R; O'Flaherty, D

    1998-01-01

    We conducted a prospective randomized study of success rate and time to intubation using Trachlight and Surch-Lite lighted stylets versus a regular tracheal tube stylet, in a training setting. Participants, 18 paediatric transport paramedics, performed two intubations with each of the three devices, using an airway management trainer. There was no significant difference in mean time for intubation between the three devices. The times for external confirmation of correct tube placement were comparable using the two lighted stylets. External confirmation of the tube placement using the lighted stylets was quicker than laryngoscopic visualization. In darkness, with a nonfunctioning laryngoscope, intubations were successfully performed 100% of the time with the lighted stylet, but only 11% of the time with the regular stylet. All paramedics felt that a lighted stylet would be a useful airway management adjunct for the transport environment for complicated intubations or for use in very high or low levels of ambient light.

  14. Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial

    PubMed Central

    Pournajafian, Ali Reza; Ghodraty, Mohammad Reza; Faiz, Seyed Hamid Reza; Rahimzadeh, Poupak; Goodarzynejad, Hamidreza; Dogmehchi, Enseyeh

    2014-01-01

    Background: To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope. Objectives: The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals receiving general anesthesia for elective surgeries. Patients and Methods: Ninety five healthy adult patients with American Society of Anesthesiologists physical status class I or II that were scheduled for elective surgery under general anesthesia were randomly allocated to either Macintosh or GlideScope arms. All patients received a standardized protocol of general anesthesia. Hemodynamic changes associated with intubation were recorded before and at 1, 3 and 5 minutes after the intubation. The time taken to perform endotracheal intubation was also noted in both groups. Results: Immediately before laryngoscopy (pre-laryngoscopy), the values of all hemodynamic variables did not differ significantly between the two groups (All P values > 0.05). Blood pressures and HR values changed significantly over time within the groups. Time to intubation was significantly longer in the GlideScope (15.9 ± 6.7 seconds) than in the Macintosh group (7.8 ± 3.7 sec) (P< 0.001). However, there were no significant differences between the two groups in hemodynamic responses at all time points. Conclusions: The longer intubation time using GVL suggests that the benefit of GVL could become apparent if the time taken for orotracheal intubation could be decreased in GlideScope group. PMID:24910788

  15. Intubation of prehospital patients with curved laryngoscope blade is more successful than with straight blade.

    PubMed

    Alter, Scott M; Haim, Eithan D; Sullivan, Alex H; Clayton, Lisa M

    2018-02-17

    Direct laryngoscopy can be performed using curved or straight blades, and providers usually choose the blade they are most comfortable with. However, curved blades are anecdotally thought of as easier to use than straight blades. We seek to compare intubation success rates of paramedics using curved versus straight blades. Design: retrospective chart review. hospital-based suburban ALS service with 20,000 annual calls. prehospital patients with any direct laryngoscopy intubation attempt over almost 9years. First attempt and overall success rates were calculated for attempts with curved and straight blades. Differences between the groups were calculated. 2299 patients were intubated by direct laryngoscopy. 1865 had attempts with a curved blade, 367 had attempts with a straight blade, and 67 had attempts with both. Baseline characteristics were similar between groups. First attempt success was 86% with a curved blade and 73% with a straight blade: a difference of 13% (95% CI: 9-17). Overall success was 96% with a curved blade and 81% with a straight blade: a difference of 15% (95% CI: 12-18). There was an average of 1.11 intubation attempts per patient with a curved blade and 1.13 attempts per patient with a straight blade (2% difference, 95% CI: -3-7). Our study found a significant difference in intubation success rates between laryngoscope blade types. Curved blades had higher first attempt and overall success rates when compared to straight blades. Paramedics should consider selecting a curved blade as their tool of choice to potentially improve intubation success. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Acoustic propagation in curved ducts with extended reacting wall treatment

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation was employed to study the attenuation of acoustic waves propagating in two-dimensional S-curved ducts with absorbing walls without a mean flow. The reflection and transmission at the entrance and the exit of a curved duct were determined by coupling the finite-element solutions in the curved duct to the eigenfunctions of an infinite, uniform, hard wall duct. In the frequency range where the duct height and acoustic wave length are nearly equal, the effects of duct length, curvature (duct offset) and absorber thickness were examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. A means of reducing the number of elements in the absorber region was also presented. In addition, for a curved duct, power attenuation contours were examined to determine conditions for maximum acoustic power absorption. Again, wall curvature was found to significantly effect the optimization process.

  17. Manikin Laryngoscopy Motion as a Predictor of Patient Intubation Outcomes: A Prospective Observational Study

    PubMed Central

    Kedarisetty, Suraj; Johnson, Jennifer Moitoza; Glaser, Dale; Delson, Nathan

    2018-01-01

    Background: The goal of this study was to determine whether motion parameters during laryngoscopy in a manikin differed with experienced operators versus novice trainees and whether motion measurements would predict trainee outcomes when intubating patients. Methods: Motion, force, and duration of laryngoscopy on a manikin were compared in two separate experiments between beginning anesthesiology residents (CA1) and anesthesiologists with more than 24 months of anesthesiology training (CA3 or attendings). In one experiment, CA1 residents were also evaluated for the percentage of their laryngoscope path that followed the route used by attending anesthesiologists. The residents were then observed for patient intubation outcomes for 4 weeks after manikin testing. The relationship between manikin test metrics and patient intubation outcomes was analyzed by multilevel modeling. Results: CA1 residents positioned the laryngoscope blade farther right and with less lift than did experienced anesthesiologists. Endpoint position was 0.6 ± 0.3 cm left of midline for residents (n = 10) versus 2.7 ± 0.3 cm for advanced anesthesiologists (n = 8; P = .0003), and 15.6 ± 0.8 versus 17.7 ± 0.2 cm above the table surface, respectively (P = .033). On average, only 74 ± 6% of the CA1 laryngoscopy trajectory coincided with the Attending Route (P < .001 versus 100%). For each percentage point increase in Attending Route match, residents' odds of intubating a patient's trachea improved by a factor of 1.033 (95% confidence interval [CI] 1.007–1.059, P = .040), and their rate of failed laryngoscopy attempts decreased by a factor of 0.982 (0.969–0.996, P = .045). Discussion: Laryngoscopy motion in manikins may predict which trainees can complete a patient intubation successfully in a few attempts. The assessment could help determine readiness for intubating patients with indirect supervision.

  18. Transition duct assembly with modified trailing edge in turbine system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMahan, Kevin Weston; Schott, Carl Gerard; Ingram, Clint Luigie

    2016-10-04

    Transition duct assemblies for turbine systems and turbomachines are provided. In one embodiment, a transition duct assembly includes a plurality of transition ducts disposed in a generally annular array and comprising a first transition duct and a second transition duct. Each of the plurality of transition ducts includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of each transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct assembly further includes anmore » aerodynamic structure defined by the passages of the first transition duct and the second transition duct. The aerodynamic structure includes a pressure side, a suction side, and a trailing edge, the trailing edge having a modified aerodynamic contour.« less

  19. Cholestasis‐induced adaptive remodeling of interlobular bile ducts

    PubMed Central

    Damle‐Vartak, Amruta; Richter, Beate; Dirsch, Olaf; Dahmen, Uta; Hammad, Seddik

    2016-01-01

    Cholestasis is a common complication in liver diseases that triggers a proliferative response of the biliary tree. Bile duct ligation (BDL) is a frequently used model of cholestasis in rodents. To determine which changes occur in the three‐dimensional (3D) architecture of the interlobular bile duct during cholestasis, we used 3D confocal imaging, surface reconstructions, and automated image quantification covering a period up to 28 days after BDL. We show a highly reproducible sequence of interlobular duct remodeling, where cholangiocyte proliferation initially causes corrugation of the luminal duct surface, leading to an approximately five‐fold increase in surface area. This is analogous to the function of villi in the intestine or sulci in the brain, where an expansion of area is achieved within a restricted volume. The increase in surface area is further enhanced by duct branching, branch elongation, and loop formation through self‐joining, whereby an initially relatively sparse mesh surrounding the portal vein becomes five‐fold denser through elongation, corrugation, and ramification. The number of connections between the bile duct and the lobular bile canalicular network by the canals of Hering decreases proportionally to the increase in bile duct length, suggesting that no novel connections are established. The diameter of the interlobular bile duct remains constant after BDL, a response that is qualitatively distinct from that of large bile ducts, which tend to enlarge their diameters. Therefore, volume enhancement is only due to net elongation of the ducts. Because curvature and tortuosity of the bile duct are unaltered, this enlargement of the biliary tree is caused by branching and not by convolution. Conclusion: BDL causes adaptive remodeling that aims at optimizing the intraluminal surface area by way of corrugation and branching. (Hepatology 2016;63:951–964) PMID:26610202

  20. Surgical treatment of chronic pancreatitis with pancreatic main duct dilatation: Long term results after head resection and duct drainage

    PubMed Central

    Schwarz, A.; Beger, H. G.

    2005-01-01

    Tissue and duct hypertension is considered as a major factor in the etiology of pain in patients with chronic pancreatitis (CP). Duct dilatation is a consequence of duct obstruction due to scars or duct stones. Nevertheless, the procedure of choice, drainage or resection, is still under discussion. We present long-term results of patients operated with duodenum-preserving pancreatic head resection (DPPHR) combined with a Partington-Rochelle duct drainage in cases of chronic pancreatitis with multiple stenosis and dilatation of the side ducts. Methods and patients. From April 1982 to September 2001, in 55 out of 538 patients with chronic pancreatitis, a DPPHR with additionally Partington-Rochelle duct drainage was performed (44 male, 11 female, mean age 45.8 years). Ninety-two percent of the patients suffered from alcoholic pancreatitis. Medical respective pain treatment for chronic pancreatitis was in median 64.5 months prior to surgery. The indications for surgery were in 87% pain, 59% of the patients had an inflammatory mass in the head of the pancreas, 36% a common bile duct stenosis and 5% a severe stenosis of the duodenum. The endocrine function (OGGT) was impaired in 79% of the patients preoperatively. Results. Hospital mortality was 0%, postoperative complications occurred in 11 patients. Follow-up: All except 2 patients were followed up in the outpatient clinic with the mean follow-up time of 69.7 months (8–105 months), the late mortality was 9%. Sixty-eight percent of the patients were completely free of pain, 29% had occasional pain, 3% suffered from a further attack of pancreatitis. Body weight increased in 79%, 58% were professionally rehabilitated. Late postoperative endocrine function was unchanged in 85% (improved in 5%, deteriorated in 10%). Conclusion. The pain control in patients with multiple duct stenosis after duodenum-preserving pancreatic head resection with duct drainage leads to long-standing absence of pain and low recurrence rate of

  1. A Comparison Between the Conventional and the Laryngoscope-Assisted Lightwand Intubation Techniques in Patients With Cervical Immobilization: A Prospective Randomized Study.

    PubMed

    Kim, Eugene; Kim, Byung-Gun; Lim, Young-Jin; Jeon, Young-Tae; Hwang, Jung-Won; Lee, Seo-Yun; Park, Hee-Pyoung

    2017-09-01

    Positioning of a lightwand in the midline of the oral cavity can be challenging in patients with cervical immobilization. Direct laryngoscopy may permit the lightwand tip to more easily access the glottic opening. We tested our hypothesis that a laryngoscope-assisted lightwand technique allows more successful endotracheal intubation than does a conventional lightwand approach. A total of 162 patients requiring cervical immobilization during intubation for cervical spine surgery were allocated randomly to 2 groups. The conventional lightwand technique (group C, n = 80) or the laryngoscope-assisted lightwand technique (group L, n = 82) was used for endotracheal intubation. In the group L, a Macintosh laryngoscope was inserted into the oral cavity, advanced until the epiglottis tip was visible, but not used to lift the epiglottis tip. The lightwand tip was placed below the epiglottis under direct view of the epiglottis tip. The primary outcome (the initial intubation success rate) and secondary outcomes (intubation time, hemodynamic changes, and postoperative airway complications) were evaluated. The initial intubation success rate was significantly lower (75% vs 89%; relative risk [95% confidence interval]: 1.2 [1.0-1.4]; P = .034) in group C than group L. The intubation time (22 ± 13 vs 24 ± 12 seconds; mean difference [98.33% confidence interval]: 2.4 [-2.3 to 7.2]; P = .217) did not differ between groups. Postoperative sore throat score, incidences of hypertension and tachycardia, postoperative oral mucosal bleeding, and hoarseness also did not differ between groups. Laryngoscope-assisted lightwand intubation did not increase intubation time, and it increased first attempt intubation rates compared with traditional lightwand intubation in patients requiring cervical immobilization for cervical spine surgery.

  2. Design and performance of duct acoustic treatment

    NASA Technical Reports Server (NTRS)

    Motsinger, R. E.; Kraft, R. E.

    1991-01-01

    The procedure for designing acoustic treatment panels used to line the walls of aircraft engine ducts and for estimating the resulting suppression of turbofan engine duct noise is discussed. This procedure is intended to be used for estimating noise suppression of existing designs or for designing new acoustic treatment panels and duct configurations to achieve desired suppression levels.

  3. Turbofan aft duct suppressor study program listing and user's guide

    NASA Technical Reports Server (NTRS)

    Joshi, M. C.; Kraft, R. E.

    1983-01-01

    A description of the structure of the Annular Flow Duct Program (AFDP) for the calculation of acoustic suppression due to treatment in a finite length annular duct carrying sheared flow is presented. Although most appropriate for engine exhaust ducts, this program can be used to study sound propagation in any duct that maintains annular geometry over a considerable length of the duct. The program is based on the modal analysis of sound propagation in ducts with axial segments of different wall impedances. For specified duct geometry, wall impedance, flow and acoustic conditions in the duct (including mode amplitude distribution of the source) and duct termination reflection characteristics, the program calculates the suppression due to the treatment in the duct. The presence of forward and backward traveling modes in the duct due to the reflection and redistribution of modes at segment interfaces and duct end terminations are taken into account in the calculations. The effects of thin wall boundary layers (with a linear or mean flow velocity profile) on the acoustic propagation are also included in the program. A functional description of the major subroutines is included and a sample run is provided with an explanation of the output.

  4. MRI ductography of contrast agent distribution and leakage in normal mouse mammary ducts and ducts with in situ cancer.

    PubMed

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S

    2017-07-01

    High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (p<0.001) than in non-cancerous FVB/N mouse mammary ducts, perhaps due to rapid washout of contrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Generator stator core vent duct spacer posts

    DOEpatents

    Griffith, John Wesley; Tong, Wei

    2003-06-24

    Generator stator cores are constructed by stacking many layers of magnetic laminations. Ventilation ducts may be inserted between these layers by inserting spacers into the core stack. The ventilation ducts allow for the passage of cooling gas through the core during operation. The spacers or spacer posts are positioned between groups of the magnetic laminations to define the ventilation ducts. The spacer posts are secured with longitudinal axes thereof substantially parallel to the core axis. With this structure, core tightness can be assured while maximizing ventilation duct cross section for gas flow and minimizing magnetic loss in the spacers.

  6. All India Difficult Airway Association 2016 guidelines for the management of unanticipated difficult tracheal intubation in adults.

    PubMed

    Myatra, Sheila Nainan; Shah, Amit; Kundra, Pankaj; Patwa, Apeksh; Ramkumar, Venkateswaran; Divatia, Jigeeshu Vasishtha; Raveendra, Ubaradka S; Shetty, Sumalatha Radhakrishna; Ahmed, Syed Moied; Doctor, Jeson Rajan; Pawar, Dilip K; Ramesh, Singaravelu; Das, Sabyasachi; Garg, Rakesh

    2016-12-01

    The All India Difficult Airway Association (AIDAA) guidelines for management of the unanticipated difficult airway in adults provide a structured, stepwise approach to manage unanticipated difficulty during tracheal intubation in adults. They have been developed based on the available evidence; wherever robust evidence was lacking, or to suit the needs and situation in India, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the AIDAA and the Indian Society of Anaesthesiologists. We recommend optimum pre-oxygenation and nasal insufflation of 15 L/min oxygen during apnoea in all patients, and calling for help if the initial attempt at intubation is unsuccessful. Transnasal humidified rapid insufflations of oxygen at 70 L/min (transnasal humidified rapid insufflation ventilatory exchange) should be used when available. We recommend no more than three attempts at tracheal intubation and two attempts at supraglottic airway device (SAD) insertion if intubation fails, provided oxygen saturation remains ≥ 95%. Intubation should be confirmed by capnography. Blind tracheal intubation through the SAD is not recommended. If SAD insertion fails, one final attempt at mask ventilation should be tried after ensuring neuromuscular blockade using the optimal technique for mask ventilation. Failure to intubate the trachea as well as an inability to ventilate the lungs by face mask and SAD constitutes 'complete ventilation failure', and emergency cricothyroidotomy should be performed. Patient counselling, documentation and standard reporting of the airway difficulty using a 'difficult airway alert form' must be done. In addition, the AIDAA provides suggestions for the contents of a difficult airway cart.

  7. Intravenous rocuronium 0.3 mg/kg improves the conditions for tracheal intubation in cats: a randomized, placebo-controlled trial.

    PubMed

    Sakai, Daniel M; Zornow, Kailee Anne; Campoy, Luis; Cable, Christina; Appel, Leslie D; Putnam, Holly J; Martin-Flores, Manuel

    2018-01-01

    Objectives We evaluated the use of rocuronium 0.3 mg/kg intravenously (IV) to facilitate tracheal intubation in cats anesthetized for elective ovariohysterectomy. Methods Thirty female cats were randomly allocated to receive rocuronium 0.3 mg/kg IV or an equal volume of normal saline, following induction of anesthesia with ketamine and midazolam. Thirty seconds after induction, a single investigator, unaware of treatment allocation, attempted tracheal intubation. The number of attempts and the time to complete intubation were measured. Intubating conditions were assessed as acceptable or unacceptable based on a composite score consisting of five different components. Duration of apnea after induction was measured and cases of hemoglobin desaturation (SpO 2 <90%) were identified. Results Intubation was completed faster (rocuronium 12 s [range 8-75 s]; saline 60 s [range 9-120 s]) and with fewer attempts (rocuronium 1 [range 1-2]; saline 2 [range 1-3], both P = 0.006) in cats receiving rocuronium. Unacceptable intubating conditions on the first attempt occurred in 3/15 cats with rocuronium and in 10/15 with saline ( P = 0.01). Apnea lasted 4 ± 1.6 mins with rocuronium and 2.3 ± 0.5 mins with saline ( P = 0.0007). No cases of desaturation were observed. Conclusions and relevance Rocuronium 0.3 mg/kg IV improves intubating conditions compared with saline and reduces the time and number of attempts to intubate with only a short period of apnea in cats.

  8. Modified single-port non-intubated video-assisted thoracoscopic decortication in high-risk parapneumonic empyema patients.

    PubMed

    Hsiao, Chen-Hao; Chen, Ke-Cheng; Chen, Jin-Shing

    2017-04-01

    Parapneumonic empyema patients with coronary artery disease and reduced left ventricular ejection fraction are risky to receive surgical decortication under general anesthesia. Non-intubated video-assisted thoracoscopy surgery is successfully performed to avoid complications of general anesthesia. We performed single-port non-intubated video-assisted flexible thoracoscopy surgery in an endoscopic center. In this study, the possible role of our modified surgery to treat fibrinopurulent stage of parapneumonic empyema with high operative risks is investigated. We retrospectively reviewed fibrinopurulent stage of parapneumonic empyema patients between July 2011 and June 2014. Thirty-three patients with coronary artery disease and reduced left ventricular ejection fraction were included in this study. One group received tube thoracostomy, and the other group received single-port non-intubated video-assisted flexible thoracoscopy surgery decortication. Patient demographics, characteristics, laboratory findings, etiology, and treatment outcomes were compared. Mean age of 33 patients (24 males, 9 females) was 76.2 ± 9.7 years. Twelve patients received single-port non-intubated video-assisted flexible thoracoscopy surgery decortication, and 21 patients received tube thoracostomy. Visual analog scale scores on postoperative first hour and first day were not significantly different in two groups (p value = 0.5505 and 0.2750, respectively). Chest tube drainage days, postoperative fever subsided days, postoperative hospital days, and total length of stay were significantly short in single-port non-intubated video-assisted flexible thoracoscopy surgery decortication (p value = 0.0027, 0.0001, 0.0009, and 0.0065, respectively). Morbidities were low, and mortality was significantly low (p value = 0.0319) in single-port non-intubated video-assisted flexible thoracoscopy surgery decortication. Single-port non-intubated video-assisted flexible thoracoscopy surgery

  9. [Stenon or Stensen duct. How sholud we call the secretory duct of the parotid gland? Brief biography of its discoverer].

    PubMed

    Morais Pérez, D

    2004-01-01

    The duct of the parotid gland had been indiscriminately named Stenon's duct or Stensen's duct. In order to establish its origin we carried out a biographic search and a brief revision of the life of the great anatomist, geologist, palaeontologist, bishop and finally Saint Nicolaus Stensen.

  10. Transition duct with divided upstream and downstream portions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Maldonado, Jaime Javier

    2015-07-14

    Turbine systems are provided. In one embodiment, a turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion extending from the inlet and a downstream portion extending from the outlet. The turbine system further includes a rib extending from an outer surface of the duct passage, the rib dividing themore » upstream portion and the downstream portion.« less

  11. Changing patterns in endotracheal intubation for anaesthesia trainees: a retrospective analysis of 80,000 cases over 10 years.

    PubMed

    Smith, N A; Tandel, A; Morris, R W

    2011-07-01

    Several overseas studies have suggested that opportunities for anaesthesia trainees to learn and practise endotracheal intubation have decreased over time. We analysed the operating theatre data collection system at a large Australian metropolitan teaching hospital from 1998 to 2008 to determine if numbers for trainees' caseloads in general, and endotracheal intubation in particular had changed. The total caseload per trainee of approximately 800 cases per year was stable throughout the study period. The number of gastrointestinal endoscopies per trainee increased significantly with a corresponding decrease in the number of other cases. The mean number of endotracheal intubations per trainee per year fell by 10% and of supraglottic devices by 16%, neither of which was statistically significant. Endotracheal intubation for caesarean sections did however fall significantly from an average of nine to an average of six cases per trainee per year. Our findings contrast with other reports of much larger decreases in the number of endotracheal intubations performed by trainees over the last decade, but suggest that our local practice is similar to the international experience of decreasing opportunities for endotracheal intubation in obstetric anaesthesia.

  12. A Continuous Quality Improvement Airway Program Results in Sustained Increases in Intubation Success.

    PubMed

    Olvera, David J; Stuhlmiller, David F E; Wolfe, Allen; Swearingen, Charles F; Pennington, Troy; Davis, Daniel P

    2018-02-21

    Airway management is a critical skill for air medical providers, including the use of rapid sequence intubation (RSI) medications. Mediocre success rates and a high incidence of complications has challenged air medical providers to improve training and performance improvement efforts to improve clinical performance. The aim of this research was to describe the experience with a novel, integrated advanced airway management program across a large air medical company and explore the impact of the program on improvement in RSI success. The Helicopter Advanced Resuscitation Training (HeART) program was implemented across 160 bases in 2015. The HeART program includes a novel conceptual framework based on thorough understanding of physiology, critical thinking using a novel algorithm, difficult airway predictive tools, training in the optimal use of specific airway techniques and devices, and integrated performance improvement efforts to address opportunities for improvement. The C-MAC video/direct laryngoscope and high-fidelity human patient simulation laboratories were implemented during the study period. Chi-square test for trend was used to evaluate for improvements in airway management and RSI success (overall intubation success, first-attempt success, first-attempt success without desaturation) over the 25-month study period following HeART implementation. A total of 5,132 patients underwent RSI during the study period. Improvements in first-attempt intubation success (85% to 95%, p < 0.01) and first-attempt success without desaturation (84% to 94%, p < 0.01) were observed. Overall intubation success increased from 95% to 99% over the study period, but the trend was not statistically significant (p = 0.311). An integrated advanced airway management program was successful in improving RSI intubation performance in a large air medical company.

  13. Modeling water vapor and heat transfer in the normal and the intubated airways.

    PubMed

    Tawhai, Merryn H; Hunter, Peter J

    2004-04-01

    Intubation of the artificially ventilated patient with an endotracheal tube bypasses the usual conditioning regions of the nose and mouth. In this situation any deficit in heat or moisture in the air is compensated for by evaporation and thermal transfer from the pulmonary airway walls. To study the dynamics of heat and water transport in the intubated airway, a coupled system of nonlinear equations is solved in airway models with symmetric geometry and anatomically based geometry. Radial distribution of heat, water vapor, and velocity in the airway are described by power-law equations. Solution of the time-dependent system of equations yields dynamic airstream and mucosal temperatures and air humidity. Comparison of model results with two independent experimental studies in the normal and intubated airway shows a close correlation over a wide range of minute ventilation. Using the anatomically based model a range of spatially distributed temperature paths is demonstrated, which highlights the model's ability to predict thermal behavior in airway regions currently inaccessible to measurement. Accurate representation of conducting airway geometry is shown to be necessary for simulating mouth-breathing at rates between 15 and 100 l x min(-1), but symmetric geometry is adequate for the low minute ventilation and warm inspired air conditions that are generally supplied to the intubated patient.

  14. Pre-hospital tracheal intubation in patients with traumatic brain injury: systematic review of current evidence.

    PubMed

    von Elm, E; Schoettker, P; Henzi, I; Osterwalder, J; Walder, B

    2009-09-01

    We reviewed the current evidence on the benefit and harm of pre-hospital tracheal intubation and mechanical ventilation after traumatic brain injury (TBI). We conducted a systematic literature search up to December 2007 without language restriction to identify interventional and observational studies comparing pre-hospital intubation with other airway management (e.g. bag-valve-mask or oxygen administration) in patients with TBI. Information on study design, population, interventions, and outcomes was abstracted by two investigators and cross-checked by two others. Seventeen studies were included with data for 15,335 patients collected from 1985 to 2004. There were 12 retrospective analyses of trauma registries or hospital databases, three cohort studies, one case-control study, and one controlled trial. Using Brain Trauma Foundation classification of evidence, there were 14 class 3 studies, three class 2 studies, and no class 1 study. Six studies were of adults, five of children, and three of both; age groups were unclear in three studies. Maximum follow-up was up to 6 months or hospital discharge. In 13 studies, the unadjusted odds ratios (ORs) for an effect of pre-hospital intubation on in-hospital mortality ranged from 0.17 (favouring control interventions) to 2.43 (favouring pre-hospital intubation); adjusted ORs ranged from 0.24 to 1.42. Estimates for functional outcomes after TBI were equivocal. Three studies indicated higher risk of pneumonia associated with pre-hospital (when compared with in-hospital) intubation. Overall, the available evidence did not support any benefit from pre-hospital intubation and mechanical ventilation after TBI. Additional arguments need to be taken into account, including medical and procedural aspects.

  15. Comparison of the Pentax AirwayScope and McGrath MAC videolaryngoscope for endotracheal intubation in patients with a normal airway

    PubMed Central

    Lee, Jiyoung; Kwak, Hyun Jeong; Lee, Ji Yeon; Chang, Min Young; Lee, Sook Young; Kim, Jong Yeop

    2017-01-01

    Abstract Various videolaryngoscopes (VLs) have been developed to provide a better laryngeal view and facilitate difficult intubations. The goal of this study was to compare 2 VLs, the Pentax AWS and the McGrath VL, with respect to intubation time and ease of intubation. One hundred forty patients aged 19 to 65 years (American Society of Anesthesiologists classification I or II), who required tracheal intubation for elective surgery, were randomly assigned to 1 of the 2 groups: the Pentax AWS (n = 70) or the McGrath VL (n = 70). The primary outcome was time to intubation (TTI) measured by a blind observer. The intubation difficulty scale (IDS), percentage of glottic opening (POGO) scale, glottic grade, use of optimal external laryngeal manipulation (OELM), and ease of intubation were also recorded. The Pentax AWS provided a better laryngeal view than the McGrath VL with respect to the Cormack-Lehane (CL) glottic grade (1/2a/2b) (63/7/0 vs 43/24/3, P < .001) and the POGO scale (median [interquartile range, IQR]) (100 [100–100] vs 100 [80–100], P < .001). The IDS was significantly lower in the Pentax AWS group compared with the McGrath VL group (median [IQR]) (0 [0–0] vs 0 [0–1], P < .001). However, the TTI was similar in both the Pentax AWS and McGrath VL groups (median [IQR]) (30 [27–34] vs 32 [27–35] seconds, P = .440). OELM and ease of intubation were also similar between the 2 groups. The Pentax AWS offered a superior laryngeal view compared with the McGrath VL. There was no significant difference in either the intubation time or ease of intubation using these 2 devices in patients with normal airways. PMID:29145308

  16. Comparison of success of tracheal intubation using Macintosh laryngoscope-assisted Bonfils fiberscope and Truview video laryngoscope in simulated difficult airway

    PubMed Central

    Vivek, Bangaru; Sripriya, R.; Mishra, Gayatri; Ravishankar, M.; Parthasarathy, S.

    2017-01-01

    Background and Aims: Restriction of head and neck movements prevents the alignment of the oral, pharyngeal, and laryngeal axes and increases the incidence of difficult tracheal intubation in patients with cervical spine fractures. Video laryngoscopes have gained an important role in the management of difficult intubation, especially in situations with limited head and neck movements. This study compares the success of intubation using Macintosh laryngoscope assisted Bonfils® fiberscope (ML-BF) with TruviewPCD video laryngoscope (TV) in patients with simulated restricted head and neck movements. Material and Methods: One hundred and fifty-two patients satisfying the inclusion criteria were randomly allocated to two groups of 76 each. Patients were made to lie supine on the table without a pillow and a soft collar was used to restrict head and neck movements. After a standardized premedication-induction sequence, tracheal intubation was done either with ML-BF or TV. Success of intubation, time taken for successful intubation, hemodynamic changes, airway trauma, and postoperative oropharyngeal morbidity were noted. Results: Intubation was successful in all the 76 patients in direct laryngoscopy-Bonfils fiberscope group and 75 out of 76 patients in TV group within the specified time (90 s). The median time taken for successful intubation with TV and ML-BF were 44 (range 26–80) s and 49 (range 28–83) s, respectively. Hemodynamic changes, airway trauma, and postoperative oropharyngeal morbidity were similar in both groups. Conclusion: Both TV and ML-BF are equally effective for successful tracheal intubation in patients with simulated restricted head and neck movements. In cases of difficult laryngeal visualization with routine Macintosh laryngoscope, Bonfils can be used as an adjunct to achieve successful intubation in the same laryngoscopy attempt. PMID:28413282

  17. The 30-second rule: the effects of prolonged intubation attempts on oxygen saturation and heart rate in preterm infants in the delivery room.

    PubMed

    Wozniak, Madeline; Arnell, Kathy; Brown, Melissa; Gonzales, Sarah; Lazarus, Danielle; Rich, Wade; Katheria, Anup

    2018-04-01

    A duration of 30 seconds has been shown to improve the success rate of intubation attempts without any decompensation. There is limited data regarding the detrimental effects of prolonged intubation attempts in preterm infants. The aim was to determine the effect of prolonged intubation attempts on heart rate and oxygen saturation in preterm infants. We retrospectively reviewed videos and physiologic data collected during delivery room (DR) resuscitations. Infants who had a functioning pulse oximeter at the time of intubation in the delivery room were analyzed using video and analog recordings. The duration of the intubation attempt was defined as the time the laryngoscope blade was in the infant's mouth. Prolonged intubations were defined as intubations over 30 seconds. Baseline heart rate and saturations were defined as the heart rate and saturation immediately prior to the intubation attempt. Video recording was used to determine time laryngoscope was in the mouth, what other procedures were performed, and whether there was recovery between attempts. Analog data including heart rate, airway pressure and saturation was also recorded. There were 52 intubation attempts in 28 infants. The median (IQR) birth weight and gestational age were 795 (705, 972) grams and 25 (25, 27) weeks. The duration of an intubation attempt was 35 (27, 46) seconds with number of attempts 2 (1, 2). There were 34 intubation attempts greater than 30 seconds (prolonged group) and 18 attempts less than or equal to 30 seconds (short group). Longer attempts did not affect intubation success (successful 34 [25,37] seconds vs. unsuccessful 41[29, 53] seconds; P=0.05). Infants in the prolonged group had a greater decrease in oxygen saturation percentage from baseline (5±8 percent, short intubation group and 13±27 prolonged intubation group; P=0.004). There was also a significant decrease in heart rate beats per minute between the two groups (6±9 in the short intubation group and 23±29

  18. Flow control in a diffusing S-Duct

    NASA Technical Reports Server (NTRS)

    Vakili, A. D.; Wu, J. M.; Liver, P.; Bhat, M. K.

    1985-01-01

    Accurate measurements have been made of secondary flow in a 1.51 area ratio diffusing 30 deg - 30 deg S-Duct with circulair cross section. Turbulent flow was entering the duct at Mach number of 0.6, the boundary layer thickness at the duct entrance was ten percent of the duct inlet diameter. Through measurements made, local flow velocity vector as well as static and total pressures mapping of the flow at several stations were obtained. Strong secondary flow was measured in the first bend which continued into the second bend with new vorticity produced in there in the opposite direction. Surface oil flow visualization and wall pressures indicated a region of separated flow starting at theta approximately equal to 22 deg on the inside of the first bend up to theta approximately equal to 44 deg on the outside of the second bend. The flow separated in 'cyclone' form and never reattached in the duct. As a result of the secondary flow and the flow separation, significant total pressure distortion was observed at the exit of the duct. Using flow control devices the separation was eliminated while the exit distortion was improved.

  19. [Endoscopic manometry in the common bile duct].

    PubMed

    Brandstätter, G; Kratochvil, P; Stupnicki, T; Zenker, G; Justich, E; Resch, M

    1982-09-17

    Reproducible results were obtained by endoscopic transpapillary pressure measurements with the help of a constantly perfused catheter. Manometric measurements were performed in 51 patients without any premedication. 14 patients with a normal biliary system were compared with 17 patients after cholecystectomy, 14 patients with stones in the common bile duct and 6 patients after papillotomy. Although there were significant differences in the diameter of the common bile duct in the four groups, only the papillotomized patients demonstrated a distinct change of the pressure in the bile duct. In these patients almost no pressure gradient existed between the biliary ducts and the duodenum. On the other hand, there was an increase in intraluminal pressure in the 2 patients with papillary stenosis. Endoscopic manometric measurements in the common bile duct are indicated to obtain reliable data on stenosis of the papilla duodeni, insufficient papillotomy or recurrent stenosis.

  20. Preventive saline irrigation of the bile duct after the endoscopic removal of common bile duct stones.

    PubMed

    Jang, Sang Eon; Ahn, Dong-Won; Lee, Sang Hyub; Lee, Ban Seok; Jeong, Ji Bong; Hwang, Jin-Hyeok; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Kyoung Ho; Kim, Young Hoon

    2013-08-01

    Small stone fragments after an endoscopic stone extraction for choledocholithiasis may act as the nidus for recurrent choledocholithiasis. Therefore, efforts to eliminate the nidus might reduce the recurrence of choledocholithiasis and cholangitis related to choledocholithiasis. The purpose of this study was to determine whether an additional preventive saline irrigation of the bile duct after the endoscopic removal of common bile duct stones would decrease residual stones and the recurrence of cholangitis. A retrospective analysis was performed for the consecutively collected data about the patients who underwent the complete endoscopic treatment for common bile duct stone. Among 99 patients, 45 patients underwent saline irrigation. Residual stones were detected in 18 patients (18.2 %). The incidences of residual stones were 8.9 % (4 of 45 patients) in the irrigation group and 25.9 % (14 of 54 patients) in the non-irrigation group (P = 0.037). In multivariate analysis, preventive saline irrigation was found to be the only significant factor for the decrease of residual stones (HR = 0.258, P = 0.039). When analyzing the occurrence of recurrent cholangitis and the procedure related to complications, there were no significant differences according to the performance of preventive saline irrigation of the bile duct. Preventive saline irrigation could reduce the residual common bile duct stones without complications.

  1. A Comparison of the C-MAC Video Laryngoscope to the Macintosh Direct Laryngoscope for Intubation in the Emergency Department

    PubMed Central

    Sakles, John C.; Mosier, Jarrod; Chiu, Stephen; Cosentino, Mari; Kalin, Leah

    2015-01-01

    Study objective We determine the proportion of successful intubations with the C-MAC video laryngoscope (C-MAC) compared with the direct laryngoscope in emergency department (ED) intubations. Methods This was a retrospective analysis of prospectively collected data entered into a continuous quality improvement database during a 28-month period in an academic ED. After each intubation, the operator completed a standardized data form evaluating multiple aspects of the intubation, including patient demographics, indication for intubation, device(s) used, reason for device selection, difficult airway characteristics, number of attempts, and outcome of each attempt. Intubation was considered ultimately successful if the endotracheal tube was correctly inserted into the trachea with the initial device. An attempt was defined as insertion of the device into the mouth regardless of whether there was an attempt to pass the tube. The primary outcome measure was ultimate success. Secondary outcome measures were first-attempt success, Cormack-Lehane view, and esophageal intubation. Multivariate logistic regression analyses, with the inclusion of a propensity score, were performed for the outcome variables ultimate success and first-attempt success. Results During the 28-month study period, 750 intubations were performed with either the C-MAC with a size 3 or 4 blade or a direct laryngoscope with a Macintosh size 3 or 4 blade. Of these, 255 were performed with the C-MAC as the initial device and 495 with a Macintosh direct laryngoscope as the initial device. The C-MAC resulted in successful intubation in 248 of 255 cases (97.3%; 95% confidence interval [CI] 94.4% to 98.9%). A direct laryngoscope resulted in successful intubation in 418 of 495 cases (84.4%; 95% CI 81.0% to 87.5%). In the multivariate regression model, with a propensity score included, the C-MAC was positively predictive of ultimate success (odds ratio 12.7; 95% CI 4.1 to 38.8) and first-attempt success (odds

  2. Traumatic resin ducts as indicators of bark beetle outbreaks

    Treesearch

    R. Justin DeRose; Matthew F. Bekker; James N. Long

    2017-01-01

    The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...

  3. Coupled parametric design of flow control and duct shape

    NASA Technical Reports Server (NTRS)

    Florea, Razvan (Inventor); Bertuccioli, Luca (Inventor)

    2009-01-01

    A method for designing gas turbine engine components using a coupled parametric analysis of part geometry and flow control is disclosed. Included are the steps of parametrically defining the geometry of the duct wall shape, parametrically defining one or more flow control actuators in the duct wall, measuring a plurality of performance parameters or metrics (e.g., flow characteristics) of the duct and comparing the results of the measurement with desired or target parameters, and selecting the optimal duct geometry and flow control for at least a portion of the duct, the selection process including evaluating the plurality of performance metrics in a pareto analysis. The use of this method in the design of inter-turbine transition ducts, serpentine ducts, inlets, diffusers, and similar components provides a design which reduces pressure losses and flow profile distortions.

  4. A meta-analysis of prehospital airway control techniques part I: orotracheal and nasotracheal intubation success rates.

    PubMed

    Hubble, Michael W; Brown, Lawrence; Wilfong, Denise A; Hertelendy, Attila; Benner, Randall W; Richards, Michael E

    2010-01-01

    Airway management is a key component of prehospital care for seriously ill and injured patients. Although endotracheal intubation has been a commonly performed prehospital procedure for nearly three decades, the safety and efficacy profile of prehospital intubation has been challenged in the last decade. Reported intubation success rates vary widely, and established benchmarks are lacking. We sought to determine pooled estimates for oral endotracheal intubation (OETI) and nasotracheal intubation (NTI) placement success rates through a meta-analysis of the literature. We performed a systematic literature search for all English-language articles reporting placement success rates for prehospital intubation. Studies of field procedures performed by prehospital personnel from any nation were included. All titles were reviewed independently by two authors using prespecified inclusion criteria. Pooled estimates of success rates for each airway technique, including drug-facilitated intubation (DFI) and rapid-sequence intubation (RSI), were calculated using a random-effects model. Historical trends were evaluated using meta-regression. Of 2,005 identified titles reviewed, 117 studies addressed OETI and 23 addressed NTI, encompassing a total of 57,132 prehospital patients. There was substantial interrater reliability in the review process (kappa = 0.81). The pooled estimates (and 95% confidence intervals [CIs]) for intervention success for nonphysician clinicians were as follows: overall non-RSI/non-DFI OETI success rate: 86.3% (82.6%-89.4%); OETI for non-cardiac arrest patients: 69.8% (50.9%-83.8%); DFI 86.8% (80.2%-91.4%); and RSI 96.7% (94.7%-98.0%). For pediatric patients, the paramedic OETI success rate was 83.2% (55.2%-95.2%). The overall NTI success rate for nonphysician clinicians was 75.9% (65.9%-83.7%). The historical trend of OETI reflects a 0.49% decline in success rates per year. We provide pooled estimates of placement success rates for prehospital airway

  5. [Causes of vocal cord dyscinesia and its original factors after endotracheal intubation].

    PubMed

    Sun, Anke; Zhang, Tiezheng; Liu, Wenyuan; Tang, Weiwei; Guo, Xiaohong

    2012-03-01

    To research the causes of postintubation vocal cord dyskinesia and its contributing factors. The causes of vocal cord dyskinesia were confirmed by laryngoscope, three-dimensional spiral CT, stroboscope, and the analysis of therapy. The factors relevant to the causes of vocal cord dyskinesia were analysed based on the following elements: (1) the anatomic or pathological condition of patients or the technical skills of anesthetists. (2) emaciated or obese body and neck. (3) the age of patients. (4) the duration of endotracheal tube retention. (5) the types of operations. (6) anesthesia procedure. Among 135 patients, 128 cases (94.81%) manifested arytenoid dislocation, 7 cases (5.19%) vocal cord paralysis. The study showed that the vocal cord dyskinesia associated with anatomic or pathological condition of patients and technical skills of anesthetists (with intubation difficulty) accounted for 76.30%. The patients with relative emaciated body or neck accounted for 90.62% in cases without intubation difficulty. Age had no significant analytical relationship with vocal cord dyskinesia. Prolonged intubation (endotracheal tube retention over 12 hours) was accounted for only 17.64%. The incidence of vocal cord dyskinesia was nearly 0.5% in patients underwent cardio-thoracic surgery, accounting for 59.26% of all the patients. There are two major causes of vocal cord dyskinesia: arytenoid dislocation and vocal cord paralysis, and the rate of vocal cord dyskinesia could be reduced by the improvement of technical skill of anesthetists and/or sufficient attention to the intubation condition of patients.

  6. Snake scope camera assisted endotracheal intubation: a procedural skills training in cadaver to prepare preclinical students for their clerkships.

    PubMed

    Tansatit, Tanvaa; Apinuntrum, Prawit; Phetudom, Thavorn

    2012-02-01

    Preparing students to perform specific procedures on patients presents a challenge of student confidence in performing these tasks. This descriptive study determined the ability of the medical students to perform a basic clinical task after a short hands-on training workshop in cadavers. This basic procedural skills training was an attempt for developing conceptual understanding and increasing procedural skills in endotracheal intubation of the medical students. The students were trained to perform two different endotracheal intubations, uncomplicated intubation, and a traumatic difficult airway scenario. The training session consisted of two methods of endotracheal intubation, oral intubations using direct laryngoscopy (DL) in two cadavers with uncomplicated airway and the Flexible Snake Scope camera (FSSC) assisted nasal intubation procedures in two cadavers simulated trauma victims with difficult airway. In the assessment session, the students performed one timed trial with each device. All four cadavers were changed but the scenarios were the same. The groups of the medical students were randomly assigned to perform the tasks in one of two cadavers of the two scenarios. Thirty-two medical students participated in this training and assessment. The training session and the assessment lasted five hours and three hours respectively. No student was asked to perform the second trial. The average time for successful intubation with DL was 32.7 seconds (SD, 13.8 seconds) and for FSSC was 127.0 seconds (SD, 32.6 seconds). The intubation failure rate was 0% for the entire study. The medical students have the ability to accomplish a basic clinical task after a short hands-on training workshop.

  7. Topical airway anesthesia for awake fiberoptic intubation: Comparison between airway nerve blocks and nebulized lignocaine by ultrasonic nebulizer

    PubMed Central

    Gupta, Babita; Kohli, Santvana; Farooque, Kamran; Jalwal, Gopal; Gupta, Deepak; Sinha, Sumit; Chandralekha

    2014-01-01

    Overview: Awake fiberoptic bronchoscope (FOB) guided intubation is the gold standard of airway management in patients with cervical spine injury. It is essential to sufficiently anesthetize the upper airway before the performance of awake FOB guided intubation in order to ensure patient comfort and cooperation. This randomized controlled study was performed to compare two methods of airway anesthesia, namely ultrasonic nebulization of local anesthetic and performance of airway blocks. Materials and Methods: A total of 50 adult patients with cervical spine injury were randomly allocated into two groups. Group L received airway anesthesia through ultrasonic nebulization of 10 ml of 4% lignocaine and Group NB received airway blocks (bilateral superior laryngeal and transtracheal recurrent laryngeal) each with 2 ml of 2% lignocaine and viscous lignocaine gargles. FOB guided orotracheal intubation was then performed. Hemodynamic variables at baseline and during the procedure, patient recall, vocal cord visibility, ease of intubation, coughing/gagging episodes, and signs of lignocaine toxicity were noted. Results: The observations did not reveal any significant differences in demographics or hemodynamic parameters at any time during the study. However, the time taken for intubation was significantly lower in Group NB as compared with the Group L. Group L had an increased number of coughing/gagging episodes as compared with Group NB. Vocal cord visibility and ease of intubation were better in patients who received airway blocks and hence the amount of supplemental lignocaine used was less in this group. Overall patient comfort was better in Group NB with fewer incidences of unpleasant recalls as compared with Group L. Conclusion: Upper airway blocks provide better quality of anesthesia than lignocaine nebulization as assessed by patient recall of procedure, coughing/gagging episodes, ease of intubation, vocal cord visibility, and time taken to intubate. PMID:25538514

  8. Success of Intubation Rescue Techniques after Failed Direct Laryngoscopy in Adults: A Retrospective Comparative Analysis from the Multicenter Perioperative Outcomes Group.

    PubMed

    Aziz, Michael F; Brambrink, Ansgar M; Healy, David W; Willett, Amy Wen; Shanks, Amy; Tremper, Tyler; Jameson, Leslie; Ragheb, Jacqueline; Biggs, Daniel A; Paganelli, William C; Rao, Janavi; Epps, Jerry L; Colquhoun, Douglas A; Bakke, Patrick; Kheterpal, Sachin

    2016-10-01

    Multiple attempts at tracheal intubation are associated with mortality, and successful rescue requires a structured plan. However, there remains a paucity of data to guide the choice of intubation rescue technique after failed initial direct laryngoscopy. The authors studied a large perioperative database to determine success rates for commonly used intubation rescue techniques. Using a retrospective, observational, comparative design, the authors analyzed records from seven academic centers within the Multicenter Perioperative Outcomes Group between 2004 and 2013. The primary outcome was the comparative success rate for five commonly used techniques to achieve successful tracheal intubation after failed direct laryngoscopy: (1) video laryngoscopy, (2) flexible fiberoptic intubation, (3) supraglottic airway as part of an exchange technique, (4) optical stylet, and (5) lighted stylet. A total of 346,861 cases were identified that involved attempted tracheal intubation. A total of 1,009 anesthesia providers managed 1,427 cases of failed direct laryngoscopy followed by subsequent intubation attempts (n = 1,619) that employed one of the five studied intubation rescue techniques. The use of video laryngoscopy resulted in a significantly higher success rate (92%; 95% CI, 90 to 93) than other techniques: supraglottic airway conduit (78%; 95% CI, 68 to 86), flexible bronchoscopic intubation (78%; 95% CI, 71 to 83), lighted stylet (77%; 95% CI, 69 to 83), and optical stylet (67%; 95% CI, 35 to 88). Providers most frequently choose video laryngoscopy (predominantly GlideScope [Verathon, USA]) to rescue failed direct laryngoscopy (1,122/1,619; 69%), and its use has increased during the study period. Video laryngoscopy is associated with a high rescue intubation success rate and is more commonly used than other rescue techniques.

  9. Review article: video-laryngoscopy: another tool for difficult intubation or a new paradigm in airway management?

    PubMed

    Paolini, Jean-Baptiste; Donati, François; Drolet, Pierre

    2013-02-01

    An adequate airway management plan is essential for patient safety. Recently, new tools have been developed as alternatives to direct laryngoscopy and intubation. Among these, video-laryngoscopy has enjoyed a rapid increase in popularity and is now considered by many as the first-line technique in airway management. This paradigm shift may have an impact on patient safety. Studies show that video-laryngoscopes are associated with better glottic visualization, a higher success rate for difficult airways, and a faster learning curve, resulting in a higher success rate for intubations by novice physicians. Thus, unanticipated difficult intubations may be less frequent if video-laryngoscopy is used as the first-line approach. In addition, on-screen viewing by the operator creates a new dynamic interaction during airway management. The entire operating room team can assess progress in real time, which enhances communication and improves teaching. However, if video-laryngoscopes become standard tools for tracheal intubation, these more costly devices will need to be widely available in all locations where airway management is conducted. Furthermore, algorithms for difficult intubation will require modification, and the question of selecting alternate devices will arise. If the incidence of difficult intubation decreases, the lack of motivation to teach and learn the use of alternative devices might adversely impact patient safety. The greater effectiveness of video-laryngoscopes associated with multi-person visualization could enhance overall patient safety during airway management. However, the routine use of video-laryngoscopy also introduces some issues that need to be addressed to avoid potentially dangerous pitfalls.

  10. Critical Analyses and Development of Training Mechanisms: Cholinergic Crisis and Pediatric/Neonatal Intubation

    DTIC Science & Technology

    2013-12-01

    194-195. 9. Akierman A, Daya K , McPhail K , Singhal N, Steinke C, Thomson B . A comparison of three neonatal intubation training programs in calgary...1995;10(4):251-258. 226. Ruetzler K , Roessler B , Potura L, et al. Performance and skill retention of intubation by paramedics using seven different...LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON USAMRMC a. REPORT U b . ABSTRACT U c. THIS PAGE U UU

  11. Meta-analysis of Duct-to-duct versus Roux-en-Y biliary reconstruction following liver transplantation for primary sclerosing cholangitis.

    PubMed

    Pandanaboyana, Sanjay; Bell, Richard; Bartlett, Adam J; McCall, John; Hidalgo, Ernest

    2015-04-01

    This meta-analysis aimed to compare outcomes following bile duct reconstruction in patients with primary sclerosing cholangitis (PSC) undergoing liver transplantation depending on whether duct-to-duct or Roux-en-Y anastomosis was utilized. An electronic search was performed of the MEDLINE, EMBASE, PubMed databases using both subject headings (MeSH) and truncated word searches. Pooled risk ratios and mean difference were calculated using the fixed-effects and random-effects models for meta-analysis. Ten studies including 910 patients met the inclusion criteria. There was no difference in the overall incidence of biliary strictures between the two groups [odds ratio (OR) 1.06 (0.68, 1.66); (P = 0.80)]. The anastomotic stricture rate was similar, [OR 1.18 (0.56, 2.50); (P = 0.67)]. Ascending cholangitis was higher in the Roux-en-Y group [OR 2.91 (1.17, 7.23); (P = 0.02)]. Anastomotic bile leak rates, graft survival, PSC recurrence and number of patients diagnosed with cholangiocarcinoma following transplantation were comparable between both groups. Duct-to-duct and Roux-en-Y reconstruction had comparable outcomes. Both techniques are associated with similar incidence of biliary stricture. The bilioenteric reconstruction was associated with a higher risk of cholangitis. The incidence of de novo cholangiocarcinoma was similar in both groups. Duct-to-duct reconstruction should be considered when feasible in patients with PSC. © 2015 Steunstichting ESOT.

  12. Effect of cricoid pressure on laryngeal view during prehospital tracheal intubation: a propensity-based analysis.

    PubMed

    Caruana, Emmanuel; Chevret, Sylvie; Pirracchio, Romain

    2017-03-01

    The benefit of cricoid pressure during tracheal intubation is still debated and, due to its potential negative impact on laryngeal views, its routine use is questioned. The goal of this study was to estimate its impact on laryngeal view. All patients intubated in the prehospital setting were included. Three different propensity score (PS) models were used and compared in terms of the balance achieved between those patients who received cricoid pressure and those who did not. The PS model that optimised the balance was retained in order to estimate the relationship between cricoid pressure and the following outcomes: difficult laryngoscopy, intubation-related complications and difficult intubation. Among the 1195 patients included, 499 (41.7%) received cricoid pressure. The optimal PS included seven variables (cardiac arrest, altered neurological status, shock, respiratory distress, gender, obesity, patient's position). After PS matching, no significant risk difference (RD) in the rate of difficult laryngoscopy was found between the patients who received cricoid pressure and those who did not (RD=0.001, 95% CI -0.07 to 0.08, p=0.50). No significant difference was found in terms of difficult intubation (RD=0.06, 95% CI -0.13 to 0.25, p=0.28) and in terms of prevalence of complications, except for airway trauma that were more frequent in cricoid pressure group (RD=0.03, 95% CI 0.002 to 0.05, p=0.01). No significant relationship was found between the use of cricoid pressure for prehospital intubation and difficult laryngoscopy. Cricoid pressure was found to be associated with more airway trauma. This finding could question its routine use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. The dose effect of ephedrine on the onset time and intubating conditions after cisatracurium administration

    PubMed Central

    Cha, Dong Guk; Jeong, Ji Seon; Kwon, Hye Mee

    2014-01-01

    Background The aim of this randomized, double-blind, placebo-controlled study was to evaluate dose effects of ephedrine pretreatment on the onset time and intubating conditions after cisatracurium administration. Methods A total of 140 adult patients were randomized into 4 groups to receive either 30 µg/kg ephedrine (Group 30, n = 35), 70 µg/kg ephedrine (Group 70, n = 35), 110 µg/kg ephedrine (Group 110, n = 35), 3 ml normal saline (Group C, n = 35) as pretreatment given 30 s before anesthetic induction. Neuromuscular block was achieved with 0.15 mg/kg cisatracurium, evaluated accelomyographically with train-of-four stimulation. An anesthesiologist blinded to patient grouping assessed the intubating conditions 1.5 min after cisatracurium administration. Results An onset time of 70 s was obtained in the ephedrine groups (Group 30: 155.4 ± 44.7 s, Group 70: 152.6 ± 40.3 s, Group 110: 151.2 ± 51.6 s) compared to Group C (224.6 ± 56.9 s) after 0.15 mg/kg of cisatracurium (P < 0.001). Ephedrine doses of either 70 or 110 µg/kg for pretreatment significantly improved intubating conditions (P < 0.05). Systolic and diastolic blood pressure and heart rate at 1 min after tracheal intubation were significantly increased than other times in all groups (P < 0.001), with no differences among the groups. However, 5 patients in Group 110 experienced marked hypertension (systolic/diastolic blood pressure: > 200/100 mmHg) 1 min after tracheal intubation with no patients in other groups. Conclusions We conclude that pre-treatment with ephedrine 70 µg/kg improved intubating conditions 1.5 min after cisatracurium administration and facilitated the onset of neuromuscular block (70 s) without adverse hemodynamic effects. PMID:25097735

  14. Air-Q® versus LMA Fastrach™ for fiberoptic-guided intubation: A randomized cross-over manikin trial.

    PubMed

    Portas, M; Canal, M I; Barrio, M; Alonso, M; Cabrerizo, P; López-Gil, M; Zaballos, M

    2018-03-01

    Airway management is still a major cause of anesthesia-associated morbidity and mortality. Supraglottic devices are recommended in difficult airway management guidelines. The aim of this study was to compare the performance of the Air-Q ® and the LMA Fastrach™ for fiberoptic guided tracheal intubation. Thirty-three anesthesia trainees participated in this randomized crossover study. Time to insert the dedicated airways (insertion of the airway into the manikin and delivery of two breaths), time to tracheal intubation (fiberoptic-guided tracheal intubation), time to remove the dedicated airway (removal of the Air-Q ® /LMA Fastrach™ over the tracheal tube) and the opinion of the ease of use of the anesthesia trainees were measured. There was 100% success rate for tracheal intubation with both devices on the first attempt. Time to insert the dedicated device and deliver two breaths was 10±3s for the Air-Q ® and 11±3s for the LMA Fastrach™, P=.07. Time taken to intubate the trachea was shorter with the air-Q ® , 38±15 s, than with the LMA Fastrach™, 47±19s, P=.017. Overall procedure time was significantly shorter with the Air-Q ® as compared with the LMA Fastrach™, with a mean time of 74±21s and 87±28s respectively, P=.002. Air-Q ® removal was considered easier than LMA Fastrach™ removal, P=.005. There were no tube dislodgements during the removal of the dedicated airways. Inexperienced anesthesia residents can perform fiberoptic-guided intubation through Air-Q ® and LMA Fastrach™ in a clinically acceptable time with high success. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Lesions of the segmental and lobar hepatic ducts.

    PubMed Central

    Longmire, W P; Tompkins, R K

    1975-01-01

    Despite reports to the contrary, unobstructed drainage of 50% of an otherwise normal liver through either the right or left uninfected hepatic duct is adequate to restore normal liver function, even if the obstructed lobe remains in place. An undrained liver lobe, if present, may require no further treatment. As long as it is completely obstructed and uninfected, it will undergo a progressive asymptomatic atrophy. Cholangitis invariably develops behind a partial lobar ductal obstruction, producing jaundice, pruritis, and fever. Unless unobstructed, uninfected biliary flow can be achieved through a segmental or lobar duct, it is better that the duct be completely obstructed and the affected liver parenchyma allowed to atrophy, provided there is normal biliary flow from the residual 50% of liver. This concept is important in the management of injured anomalous segmental or lobar hepatic duct and in the palliative treatment of bile duct carcinoma. Localized intrahepatic infections communicating with abnormal biliary ducts will require hepatic resection of the infected parenchyma and ducts for cure. The abnormality may be saccular dilatation of the intrahepatic ductal system with abscess formation or intrahepatic abscess associated with stenosis of the ductal system from trauma to the duct, to the duct and liver, or to retained intrahepatic stones. Diffusely situated intrahepatic abscesses secondary to ductal abnormalities can be treated with systemic antibiotics, local drainage of a dmoninant abscess, and efforts to improve biliary drainage. Images Fig. 4. Fig. 5. Fig. 6. Fig. 8. Fig. 9. Fig. 10. Figs. 11A and B Figs. 12A and B. Fig. 13. Fig. 14. Fig. 15. Fig. 16. Fig. 17. PMID:1180585

  16. Prospective observational study of emergent endotracheal intubation practice in the intensive care unit and emergency department of an Australian regional tertiary hospital.

    PubMed

    Phillips, Luke; Orford, Neil; Ragg, Michael

    2014-08-01

    The present study aimed to describe the characteristics and outcomes of intubation occurring in the ICU and ED of an Australian tertiary teaching hospital. This was a prospective observational study of intubation practice across the Geelong Hospital over a 6 month period from 1 August 2012 to 31 January 2013. Data were entered by the intubating team through an online data collection form. There were 119 patients intubated and 134 attempts at intubation in the ED and ICU over a 6 month period. The first-pass success rate was 104/119 (87.4%), and all but a single patient was intubated by the second attempt. Propofol, fentanyl, midazolam and suxamethonium were the most common drugs used in rapid sequence induction. AEs were reported in 44/134 (32.8%) of intubation attempts, with transient hypoxia and hypotension being the most common. A significant adverse outcome, namely aspiration pneumonitis, occurred in one patient. There were no peri-intubation deaths. The majority of airways are managed by ICU and ED consultants and trainees, with success rates and AE rates comparable with other published studies. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  17. Decline of the performance of a portable axial-flow fan due to the friction and duct bending loss of a connected flexible duct.

    PubMed

    Ojima, Jun

    2017-03-28

    In a job site, a portable fan is often used to ventilate a confined space. When a portable fan is applied to such a space, the actual ventilation flow rate must be accurately estimated in advance because the safety level of contaminant and oxygen concentrations in the space will determine the ventilation requirements. When a portable fan is used with a flexible duct, the actual flow rate of the fan decreases due to the friction and duct bending loss of the duct. Intending to show the decline of a fan performance, the author conducted laboratory experiments and reported the quantitative effect of the friction and duct bending loss of a flexible duct to the flow rate of a portable fan. Four commercial portable fans of different specifications were procured for the experiments, and the decline of the performance of each portable fan due to the friction loss etc. of a connected flexible duct was investigated by measuring actual flow rate. The flow rate showed an obvious decrease from the rated flow rate when a flexible duct was connected. Connection of a straight polyester flexible duct and a straight aluminum flexible duct reduced the flow rates to 81.2 - 52.9% and less than 50%, respectively. The flow rate decreased with an increase of the bend angle of the flexible duct. It is recommended that flow rate check of a portable fan should be diligently carried out in every job site.

  18. [Iatrogenic bile duct injuries during the process of laparoscopic cholecystectomy].

    PubMed

    Qian, G; Wu, M; Zhang, Y

    1995-11-01

    Twelve patients with iatrogenic bile duct injuries occurred during laparoscopic cholecystectomy (LC) were treated from June 1992 to May 1994. All the patients underwent re-operation and were cured. The causes and characteristics of the injuries were: (1) perforation of the common hepatic or common bile duct caused by dissecting hook (3 cases); (2) necrosis and perforation of the common hepatic duct due to diathermic injury (1 case); (3) clamping of the common hepatic duct by Ti clip (1 case); (4) secondary high bile duct stricture following a failed end-to-end anastomosis or hepatico-cholangio-jejunostomy of the amputated common hepatic duct (5 cases); (5) delayed high bile duct stricture (2 cases). It is emphasized that the severity of bile duct injuries by LC be should not overlooked, and more experience in this field be accumulated to avoid this serious complication.

  19. Heterogeneity Between Ducts of the Same Nuclear Grade Involved by Duct Carcinoma In Situ (DCIS) of the Breast

    PubMed Central

    Miller, Naomi A.; Chapman, Judith-Anne W.; Qian, Jin; Christens-Barry, William A.; Fu, Yuejiao; Yuan, Yan; Lickley, H. Lavina A.; Axelrod, David E.

    2010-01-01

    Purpose Nuclear grade of breast DCIS is considered during patient management decision-making although it may have only a modest prognostic association with therapeutic outcome. We hypothesized that visual inspection may miss substantive differences in nuclei classified as having the same nuclear grade. To test this hypothesis, we measured subvisual nuclear features by quantitative image cytometry for nuclei with the same grade, and tested for statistical differences in these features. Experimental design and statistical analysis Thirty-nine nuclear digital image features of about 100 nuclei were measured in digital images of H&E stained slides of 81 breast biopsy specimens. One field with at least 5 ducts was evaluated for each patient. We compared features of nuclei with the same grade in multiple ducts of the same patient with ANOVA (or Welch test), and compared features of nuclei with the same grade in two ducts of different patients using 2-sided t-tests (P ≤ 0.05). Also, we compared image features for nuclei in patients with single grade to those with the same grade in patients with multiple grades using t-tests. Results Statistically significant differences were detected in nuclear features between ducts with the same nuclear grade, both in different ducts of the same patient, and between ducts in different patients with DCIS of more than one grade. Conclusion Nuclei in ducts visually described as having the same nuclear grade had significantly different subvisual digital image features. These subvisual differences may be considered additional manifestations of heterogeneity over and above differences that can be observed microscopically. This heterogeneity may explain the inconsistency of nuclear grading as a prognostic factor. PMID:20981137

  20. Subsonic Flows through S-Ducts with Flow Control

    NASA Astrophysics Data System (ADS)

    Chen, Yi

    An inlet duct of an aircraft connects the air intake mounted on the fuselage to the engine within the aircraft body. The ideal outflow quality of the duct is steady, uniform and of high total pressure. Recently compact S-shaped inlet ducts are drawing more attention in the design of UAVs with short propulsion system. Compact ducts usually involve strong streamwise adverse pressure gradient and transverse secondary flow, leading to large-scale harmful vortical structures in the outflow. To improve the outflow quality modern flow control techniques have to be applied. Before designing successful flow control methods a solid understanding of the baseline flow field with the duct is crucial. In this work the fundamental mechanism of how the three dimensional flow topology evolves when the relevant parameters such as the duct geometry and boundary layer thickness are varied, is studied carefully. Two distinct secondary-flow patterns are identified. For the first time the sensitivity of the flow topology to the inflow boundary layer thickness in long ducts is clearly addressed. The interaction between the transverse motion induced by the transverse pressure gradient and the streamwise separation is revealed as the crucial reason for the various flow patterns existing in short ducts. A non-symmetric flow pattern is identified for the first time in both experiments and simulations in short ducts in which the intensity of the streamwise separation and the transverse invasion are in the same order of magnitude. A theory of energy accumulation and solution bifurcation is used to give a reasonable explanation for this non-symmetry. After gaining the knowledge of where and how the harmful vortical structures are generated several flow control techniques are tested to achieve a better outflow quality. The analysis of the flow control cases also provides a deeper insight into the behavior of the three-dimensional flow within the ducts. The conventional separation control method

  1. Comparison of the laryngeal view during intubation using Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization and mouth opening limitation.

    PubMed

    Koh, Jae-Chul; Lee, Jong Seok; Lee, Youn-Woo; Chang, Chul Ho

    2010-11-01

    For patients suspicious of cervical spine injury, a Philadelphia cervical collar is usually applied. Application of Philadelphia cervical collar may cause difficult airway. The aim of this study was to evaluate the laryngeal view and the success rate at first intubation attempt of the Airtraq and conventional laryngoscopy in patients with simulated cervical spine injury after application of a Philadelphia cervical collar. Anesthesia was induced with propofol, remifentanil, and rocuronium. After a Philadelphia cervical collar applied, patients were randomly assigned to tracheal intubation with an Airtraq (Group A, n = 25) or with conventional laryngoscopy (Group L, n = 25). Measurements included intubation time, success rate of first intubation attempt, number of intubation attempts, and percentage of glottic opening (POGO) score. Mean blood pressure and heart rate were also recorded at baseline, just before and after intubation. The success rate of the first attempt in Group A (96%) was significantly greater than with the Group L (40%). POGO score was significantly greater in Group A (84 ± 20%) than in Group L (6 ± 11%). The duration of successful intubation at first tracheal intubation attempt and hemodynamic changes were not significantly different between the two groups. The Airtraq offers a better laryngeal view and higher success rate at first intubation attempt in patients who are applied with a Philadelphia cervical collar due to suspicion of cervical spine injury.

  2. Predicting vibrational failure of flexible ducting

    NASA Technical Reports Server (NTRS)

    Henry, R. H.

    1971-01-01

    Technique applies to liquid or gas transfer through flexible ducting and proves valuable in high velocity fluid flow cases. Fluid mechanism responsible for free bellows vibrational excitation also causes flexible hose oscillation. Static pressure stress influences flexible ducting fatigue life and is considered separately.

  3. Parotid salivary duct stenosis following caudal maxillectomy.

    PubMed

    Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E

    2014-01-01

    Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy.

  4. Oral to nasal tube exchange under fibroscopic view: a new technique for nasal intubation in a predicted difficult airway.

    PubMed

    Monclus, Enric; Garcés, Antonio; Artés, David; Mabrock, Maged

    2008-07-01

    For a predicted difficult airway, oral intubation techniques are well established in pediatric anesthesia, but nasotracheal intubation remains a problem. There are many reports concerning this, but the risk of bleeding, added to the lack of cooperation make this procedure difficult and hazardous. We describe a modification of the nasal intubation technique in two stages. First an oral intubation and then exchanging the oral for a nasal tube, in the case of a 13-year-old boy affected by an advanced stage of cherubism. Oral intubation using a laryngeal mask technique has already been reported, but problems appear during the exchange procedure and even more when direct laryngoscopy is impossible. Fiberscopic control of the exchange, and the introduction of a Cook Exchange Catheter into the trachea through the oral tube before withdrawal, permits oxygenation of the patient and acts as a guide for oral tube reintroduction if required.

  5. Flow duct for nuclear reactors

    DOEpatents

    Straalsund, Jerry L.

    1978-01-01

    Improved liquid sodium flow ducts for nuclear reactors are described wherein the improvement comprises varying the wall thickness of each of the walls of a polygonal tubular duct structure so that each of the walls is of reduced cross-section along the longitudinal center line and of a greater cross-section along wall junctions with the other walls to form the polygonal tubular configuration.

  6. Bile duct epithelial tight junctions and barrier function

    PubMed Central

    Rao, R.K.; Samak, G.

    2013-01-01

    Bile ducts play a crucial role in the formation and secretion of bile as well as excretion of circulating xenobiotic substances. In addition to its secretory and excretory functions, bile duct epithelium plays an important role in the formation of a barrier to the diffusion of toxic substances from bile into the hepatic interstitial tissue. Disruption of barrier function and toxic injury to liver cells appear to be involved in the pathogenesis of a variety of liver diseases such as primary sclerosing cholangitis, primary biliary cirrhosis and cholangiocarcinoma. Although the investigations into understanding the structure and regulation of tight junctions in gut, renal and endothelial tissues have expanded rapidly, very little is known about the structure and regulation of tight junctions in the bile duct epithelium. In this article we summarize the current understanding of physiology and pathophysiology of bile duct epithelium, the structure and regulation of tight junctions in canaliculi and bile duct epithelia and different mechanisms involved in the regulation of disruption and protection of bile duct epithelial tight junctions. This article will make a case for the need of future investigations toward our understanding of molecular organization and regulation of canalicular and bile duct epithelial tight junctions. PMID:24665411

  7. Analyses of radiation impedances of finite cylindrical ducts

    NASA Astrophysics Data System (ADS)

    Shao, W.; Mechefske, C. K.

    2005-08-01

    To aid in understanding the characteristics of acoustic radiation from finite cylindrical ducts with infinite flanges, mathematical expressions of generalized radiation impedances at the open ends have been developed. Newton's method is used to find the complex wavenumbers of radial modes for the absorption boundary condition. The self-radiation impedances and mutual impedances for some acoustic modes are calculated for the ducts with rigid and absorption walls. The results show that the acoustical conditions of the duct walls have a significant influence on the radiation impedance. The acoustical interaction between the two open ends of the ducts cannot be neglected, especially for plane waves. To increase the wall admittance will reduce this interference effect. This study creates the possibility for simulating the sound field inside finite ducts in future work.

  8. Turbofan Duct Propagation Model

    NASA Technical Reports Server (NTRS)

    Lan, Justin H.; Posey, Joe W. (Technical Monitor)

    2001-01-01

    The CDUCT code utilizes a parabolic approximation to the convected Helmholtz equation in order to efficiently model acoustic propagation in acoustically treated, complex shaped ducts. The parabolic approximation solves one-way wave propagation with a marching method which neglects backwards reflected waves. The derivation of the parabolic approximation is presented. Several code validation cases are given. An acoustic lining design process for an example aft fan duct is discussed. It is noted that the method can efficiently model realistic three-dimension effects, acoustic lining, and flow within the computational capabilities of a typical computer workstation.

  9. Rotating Rake Turbofan Duct Mode Measurement System

    NASA Technical Reports Server (NTRS)

    Sutliff, Daniel L.

    2005-01-01

    An experimental measurement system was developed and implemented by the NASA Glenn Research Center in the 1990s to measure turbofan duct acoustic modes. The system is a continuously rotating radial microphone rake that is inserted into the duct. This Rotating Rake provides a complete map of the acoustic duct modes present in a ducted fan and has been used on a variety of test articles: from a low-speed, concept test rig, to a full-scale production turbofan engine. The Rotating Rake has been critical in developing and evaluating a number of noise reduction concepts as well as providing experimental databases for verification of several aero-acoustic codes. More detailed derivation of the unique Rotating Rake equations are presented in the appendix.

  10. Impact of Rocuronium and Succinylcholine on Sedation Initiation After Rapid Sequence Intubation.

    PubMed

    Johnson, Eric G; Meier, Alex; Shirakbari, Alicia; Weant, Kyle; Baker Justice, Stephanie

    2015-07-01

    Rapid sequence intubation (RSI) involves a rapidly acting sedative plus a neuromuscular blocking agent (NMBA) to facilitate endotracheal intubation. Rocuronium and succinylcholine are NMBAs commonly used in RSI with drastically different durations of action. Evaluate whether patients receiving RSI with a longer-acting NMBA had a greater delay in sedation or analgesia than patients that received a short-acting NMBA. This was a retrospective review of patients presenting to the emergency department requiring endotracheal intubation. Exclusions included age < 18 years, pregnancy, prior intubation, and contraindication to sedation and analgesia. Primary endpoint was time to continuous sedation or analgesia after RSI in patients receiving rocuronium or succinylcholine. Secondary endpoints included hospital length of stay (HLOS), intensive care unit length of stay (ICU LOS), and impact of an emergency medicine pharmacist (EPh). A total 106 patients met inclusion criteria, 76 patients receiving rocuronium and 30 receiving succinylcholine. Mean time to sedation or analgesia was longer in the rocuronium group when compared to the succinylcholine group at 34 ± 36 min vs. 16 ± 21 min (p = 0.002). In the presence of an EPh, the mean time to sedation or analgesia was 20 ± 21 min, vs. 49 ± 45 min (p < 0.001). Time spent on ventilator, HLOS, and ICU LOS were not significantly different between groups. Patients receiving rocuronium in RSI had a significantly longer time to sedation or analgesia when compared to patients receiving succinylcholine. The presence of an EPh significantly decreased the time to administration of sedation or analgesia after RSI. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Prior esophagogastroduodenoscopy does not affect the cecal intubation time at bidirectional endoscopies

    PubMed Central

    Öner, Osman Zekai; Demirci, Rojbin Karakoyun; Gündüz, Umut Rıza; Aslaner, Arif; Koç, Ümit; Bülbüller, Nurullah

    2013-01-01

    Bidirectional endoscopy (BE) is often used to assess patients for the reason of anemia or to screen asymptomatic population for malignancy. Limited clinical data favors to perform first the upper gastrointestinal system endoscopy, but its effect to the duration of colonoscopy is yet to be determined. The aim of this retrospective study is to evaluate the effect of upper gastrointestinal system endoscopy on the time to achieve cecal intubation during colonoscopy in patients undergoing BE. Patients of four endoscopists at similar experience levels were retrospectively identified and categorized into the upper gastrointestinal system endoscopy before colonoscopy group (group 1) or the colonoscopy only group (group 2). The demographics, clinical data and the time to achieve cecal intubation for each patient were analyzed. The mean time to achieve cecal intubation in the first group that included 319 cases was 8.4 ± 0.93 minutes and the mean time in the second group that included 1672 cases was 8.56 ± 1.16 minutes. There was no statistically significant difference between the groups. There was also no significant difference between the Group 1 and Group 2 when compared according to which of the four endoscopists performed the procedures. Performing the upper gastrointestinal system endoscopy prior to colonoscopy did not affect the time to achieve cecal intubation. Considering that performing the upper gastrointestinal system endoscopy prior to the colonoscopy is more advantageous in terms of patient comfort and analgesic requirement, beginning to BE with it seems more favorable. PMID:23936601

  12. Clinical dysphagia risk predictors after prolonged orotracheal intubation.

    PubMed

    Medeiros, Gisele Chagas de; Sassi, Fernanda Chiarion; Mangilli, Laura Davison; Zilberstein, Bruno; Andrade, Claudia Regina Furquim de

    2014-01-01

    To elucidate independent risk factors for dysphagia after prolonged orotracheal intubation. The participants were 148 consecutive patients who underwent clinical bedside swallowing assessments from September 2009 to September 2011. All patients had received prolonged orotracheal intubations and were admitted to one of several intensive care units of a large Brazilian school hospital. The correlations between the conducted water swallow test results and dysphagia risk levels were analyzed for statistical significance. Of the 148 patients included in the study, 91 were male and 57 were female (mean age, 53.64 years). The univariate analysis results indicated that specific variables, including extraoral loss, multiple swallows, cervical auscultation, vocal quality, cough, choking, and other signs, were possible significant high-risk indicators of dysphagia onset. The multivariate analysis results indicated that cervical auscultation and coughing were independent predictive variables for high dysphagia risk. Patients displaying extraoral loss, multiple swallows, cervical auscultation, vocal quality, cough, choking and other signs should benefit from early swallowing evaluations. Additionally, early post-extubation dysfunction recognition is paramount in reducing the morbidity rate in this high-risk population.

  13. Telepresent intubation supervision is as effective as in-person supervision of procedurally naive operators.

    PubMed

    Prescher, Hannes; Grover, Emily; Mosier, Jarrod; Stolz, Uwe; Biffar, David E; Hamilton, Allan J; Sakles, John C

    2015-03-01

    Telepresence is emerging in clinical and educational settings as a potential modality to provide expert guidance during remote airway management. This study aimed to compare the effectiveness of telepresent versus in-person supervision of tracheal intubation. A randomized, crossover study was performed in a university medical simulation center with 48 first- and second-year medical students with no formal procedural training in tracheal intubation. Each participant was assigned to receive each of four study arms in random sequence: (1) direct laryngoscopy (DL) with in-person supervision, (2) DL with telepresent supervision, (3) videolaryngoscopy (VL) with in-person supervision, and (4) VL with telepresent supervision. Telepresence was established with a smartphone (Apple [Cupertino, CA] iPhone(®)) via FaceTime(®) connection. The primary outcome measure was the time to successful intubation. Secondary outcome measures included first pass success rate and the number of blade and tube attempts. There was no significant difference between in-person and telepresent supervision for any of the outcomes. The median difference (in-person versus telepresent) for time to intubation was -3 s (95% confidence interval [CI], -20 to 14 s). The odds ratio for first attempt success was 0.7 (95% CI, 0.3-1.3), and the rate ratio for extra number of blade attempts (i.e., attempts in addition to first) was 1.1 (95% CI, 0.7-1.7) and 1.4 (95% CI, 0.9-2.2) for extra number of tube attempts. In this study population of procedurally naive medical students, telepresent supervision was as effective as in-person supervision for tracheal intubation.

  14. Midline submental intubation might be the preferred alternative to oral and nasal intubation in elective oral and craniomaxillofacial surgery when indicated.

    PubMed

    Jin, Huijun; Patil, Pavan Manohar

    2015-01-01

    No consensus exists to date regarding the best method of controlling the airway for oral or craniomaxillofacial surgery when orotracheal and nasotracheal intubations are unsuccessful or contraindicated. The most commonly used method of tracheostomy has been associated with a high degree of morbidity. Therefore, the present study was conducted to determine the indications, safety, efficacy, time required, drawbacks, complications, and costs of the midline submental intubation (SMI) approach in elective oral and craniomaxillofacial surgical procedures. A retrospective case series study was used to evaluate the surgical, financial, and photographic records of all patients who had undergone oral or craniomaxillofacial operations at Sharda University School of Dental Sciences, Greater Noida, from April 2006 to March 2014. The indications, drawbacks, time required for the procedure, ability to provide a secure airway, intra- and postoperative complications, and additional costs associated with SMI were analyzed. Of the 2,823 patients treated, the present study included 120 patients (97 men and 23 women, aged 19 to 60 years). The average time required for SMI was 10 ± 2 minutes. No episode of intraoperative oxygen desaturation was noted. One intraoperative complication, an injury to the ventral surface of the tongue, was encountered. Two patients developed infection at the skin incision site. No significant additional cost was incurred with the use of SMI. SMI has been successfully used in elective oral and craniomaxillofacial surgical procedures for which oral and nasal intubations were either not indicated or not possible. The advantages include a quick procedure, insignificant complications, the ability to provide a stable airway, and no added costs, making SMI a quick, safe, efficient, and cost-effective alternative in such cases. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Albumin expression distinguishes bile duct adenomas from metastatic adenocarcinoma.

    PubMed

    Moy, Andrea P; Arora, Kshitij; Deshpande, Vikram

    2016-09-01

    Bile duct adenomas may be difficult to distinguish from metastatic carcinomas, particularly well-differentiated pancreatic ductal adenocarcinoma. Prior studies have evaluated the utility of various immunohistochemical markers, although these markers are notable for low sensitivity and/or specificity. The aim of this study was to investigate the utility of albumin and BRAFV600E expression in distinguishing between metastatic pancreatic adenocarcinoma and bile duct adenoma. We studied 26 bile duct adenomas, three bile duct hamartomas, and 158 pancreatic ductal adenocarcinomas. Branched-chain in-situ hybridization (bISH) for albumin was performed; bISH is based on the branched DNA technology, wherein signal amplification is achieved via a series of sequential steps. Additionally, BRAFV600E immunohistochemistry (IHC) was performed on a subset of cases. Twenty-three of 25 (92%) bile duct adenomas were positive for albumin; 18 (72%) showed diffuse staining, and five showed focal staining (20%), including two challenging examples. Two bile duct hamartomas also stained positively. All pancreatic adenocarcinomas were negative for albumin. Seven of 16 (44%) bile duct adenomas and five of 106 (5%) pancreatic ductal adenocarcinomas were positive for BRAFV600E by IHC. The sensitivity and specificity of expression of albumin, as detected by bISH, for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 92% and 100%, respectively; the sensitivity and specificity of BRAFV600E IHC for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 43.8% and 95.3%, respectively. Diagnostically challenging examples of bile duct adenoma may be distinguished from metastatic pancreatic adenocarcinoma by the use of albumin bISH. © 2016 John Wiley & Sons Ltd.

  16. Common Bile Duct Stricture After Laparoscopic Cholecystectomy: Case Report

    PubMed

    Zoričić, Ivan; Soldo, Ivo; Simović, Ivan; Sever, Marko; Bakula, Branko; Grbavac, Martin; Marušić, Marinko; Soldo, Anamaria

    2017-03-01

    Despite progress in laparoscopic surgery and increasing surgical experience, the incidence of bile duct injury during laparoscopic cholecystectomy fails to fall below 0.3%-0.6% and it is still higher than those recorded in the era of open cholecystectomy. Bile duct injuries belong to the most serious complications of abdominal surgery in general and often end up with liver transplantation as the only hope for cure. We present a case of a 78-year-old jaundiced male patient who sustained common hepatic duct injury during laparoscopic cholecystectomy eight months earlier. Exploratory laparotomy, ERCP and MRCP revealed a metal clip placed just below hepatic duct confluence and causing stricture of bile duct with dilatation of bile ducts proximal to the level of stenosis (Strasberg classification type E3 injury). Repair of the injury was performed by creating termino-lateral hepaticojejunostomy between the right and left hepatic ducts and retrocolic Roux en-Y jejunal limb. By presenting this case, we wish to emphasize the importance of timely conversion and execution of intraoperative cholangiography in all cases when identification of the structures of Calot’s triangle is not clear enough. Successful treatment of bile duct injury is only possible with joint approach of radiologist, gastroenterologist and experienced hepatobiliary surgeon.

  17. Long duct nacelle aerodynamic development for DC-10 derivatives

    NASA Technical Reports Server (NTRS)

    Patel, S. P.; Donelson, J. E.

    1980-01-01

    The results are presented of a wind tunnel test utilizing a 4.7-percent-scale semispan model of the DC-10 in the Calspan 8-foot transonic wind tunnel. The effect of a revised long-duct nacelle shape on the channel velocities, the incremental drag relative to the baseline long-duct nacelle, and channel velocities for the baseline long-duct nacelle were determined and compared with data obtained at Ames. The baseline and the revised long-duct nacelles are representative of a CF6-50 mixed-flow configuration and were evaluated on a model of a proposed DC-10 stretched-fuselage configuration. The results showed that the revised long-duct nacelle has an appreciable effect on the inboard channel velocities, resulting in an increased channel Mach number. However, the pressure recovery on the nacelle afterbody was about the same for both nacelles. The lift curves for both long-duct nacelle configurations were the same. The channel pressures measured at Calspan were in good agreement with those measured at Ames for the baseline long-duct nacelle. The incremental drag for the revised nacelle was measured as two to four counts (three counts is approximately equal to one percent of the airplane drag) higher than that of the baseline long-duct nacelle.

  18. Parametric study of electromagnetic waves propagating in absorbing curved S ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.

  19. Leaf seal for transition duct in turbine system

    DOEpatents

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2013-06-11

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a leaf seal contacting the interface member to provide a seal between the interface member and the turbine section.

  20. [Clinicopathologic features of drug-induced vanishing bile duct syndrome].

    PubMed

    Ye, L H; Wang, C K; Zhang, H C; Liu, Z Q; Zheng, H W

    2017-04-20

    Vanishing bile duct syndrome (VBDS) manifests as progressive destruction and disappearance of the intrahepatic bile duct caused by various factors and cholestasis. VBDS associated with drug-induced liver injury (D-VBDS) is an important etiology of VBDS, and immune disorder or immune imbalance may be the main pathogenesis. According to its clinical symptoms, serological markers, and course of the disease, D-VBDS is classified into major form and minor form, and its clinical features are based on various pathomorphological findings. Its prognosis is associated various factors including regeneration of bile duct cells, number of bile duct injuries, level and range of bile duct injury, bile duct proliferation, and compensatory shunt of bile duct branches. This disease has various clinical outcomes; most patients have good prognosis after drug withdrawal, and some patients may experience cholestatic cirrhosis, liver failure, and even death. Due to the clinical manifestation and biochemical changes are similar to the primary biliary cholangitis (PBC) and primary sclerosing cholangitis (PSC), it need to identify by clinical physician.

  1. Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)—Health Professional Version

    Cancer.gov

    Bile duct cancer (also called cholangiocarcinoma) can occur in the bile ducts in the liver (intrahepatic) or outside the liver (perihilar or distal extrahepatic). Learn about the types of bile duct cancer, risk factors, clinical features, staging, and treatment for bile duct cancer in this expert-reviewed summary.

  2. Measure Guideline: Buried and/or Encapsulated Ducts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, C.; Zoeller, W.; Mantha, P.

    2013-08-01

    Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. Some of the procedures presented here, however,more » require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license.« less

  3. Effects of premedication with oral gabapentin on intraocular pressure changes following tracheal intubation in clinically normal dogs.

    PubMed

    Trbolova, Alexandra; Ghaffari, Masoud Selk; Capik, Igor

    2017-09-19

    Gabapentin is an antiepileptic drug widely approved as an add-on therapy for epilepsy treatment in human and dogs. There is a clinical impression that gabapentin is a suitable drug which attenuates the IOP elevation associated with tracheal intubation in humans. The present study performed to determine the effects of oral gabapentin on intraocular pressure (IOP) changes following tracheal intubation in dogs. Twenty adult healthy dogs were randomly assigned to treatment (n = 10) and control (n = 10) groups. Dogs in the treatment group received oral gabapentin (50 mg/kg) 2 h before induction of anesthesia and dogs in the control group received oral gelatin capsule placebo at the same time. The dogs were anesthetized with propofol 6 mg/kg, and anesthesia was maintained with a constant infusion of 0.2 mg/kg/min of propofol for 20 min. IOP were measured immediately before induction and then repeated immediately after induction, as well as 5 min, 10 min and 15 min following tracheal intubation in both groups. IOP was significantly higher immediately after induction, and 5 min after tracheal intubation when compared with IOP reading before induction in the control group. There was no statistically significant change in IOPs immediately after induction, and 5 min after tracheal intubation in comparison to the values before induction in the treatment group. Based on the findings of this study, preanesthetic oral administration of gabapentin significantly prevents an increase in the IOP associated with tracheal intubation in dogs anesthetized with propofol.

  4. Case-controlled clinical and histopathological study of conjunctivochalasis.

    PubMed

    Francis, I C; Chan, D G; Kim, P; Wilcsek, G; Filipic, M; Yong, J; Coroneo, M T

    2005-03-01

    Conjunctivochalasis, a secondary cause of the watery eye, is frequently seen in the older age group as an elevation of the bulbar conjunctiva lying along the lateral or central lower lid margin. A prospective, interventional, case-controlled clinical and histopathological study was conducted. The relevant features of 18 patients (29 eyes) who had their conjunctivochalasis resected as part of the surgical management of their watery eye syndrome were examined. In the control group, tissue was obtained from an age matched series of 24 normal subjects undergoing routine cataract surgery. 24 controls (24 specimens) and 18 patients (29 specimens) had conjunctival strip biopsies, taken from the usual lid margin level bulbar conjunctiva in line with the inferior limbus (controls), and the clinically apparent conjunctivochalasis (patients). These were submitted for histological study. 23 of 24 control sections demonstrated normal conjunctival variation. Four of 29 patient specimens demonstrated a chronic non-granulomatous conjunctivitis, while three eyes of the patient group (two patients) demonstrated features of elastosis. Of the four patients who had the inflammatory infiltrates, three had functional nasolacrimal duct obstructions (FNLDOs) and one had a primary acquired nasolacrimal duct obstruction (PANDO). Of the two patients who had elastosis, one had an FNLDO and the other had normal lacrimal drainage and was Jones 1 positive. Six of 18 patients--that is, seven of 29 specimens of conjunctivochalasis demonstrated signs of elastosis or of chronic non-granulomatous inflammation. Clinically, patients had a spectrum of aetiologies of their watery eye syndrome.

  5. "TuNa-saving" endoscopic medial maxillectomy: a surgical technique for maxillary inverted papilloma.

    PubMed

    Pagella, Fabio; Pusateri, Alessandro; Matti, Elina; Avato, Irene; Zaccari, Dario; Emanuelli, Enzo; Volo, Tiziana; Cazzador, Diego; Citraro, Leonardo; Ricci, Giampiero; Tomacelli, Giovanni Leo

    2017-07-01

    The maxillary sinus is the most common site of sinonasal inverted papilloma. Endoscopic sinus surgery, in particular endoscopic medial maxillectomy, is currently the gold standard for treatment of maxillary sinus papilloma. Although a common technique, complications such as stenosis of the lacrimal pathway and consequent development of epiphora are still possible. To avoid these problems, we propose a modification of this surgical technique that preserves the head of the inferior turbinate and the nasolacrimal duct. A retrospective analysis was performed on patients treated for maxillary inverted papilloma in three tertiary medical centres between 2006 and 2014. Pedicle-oriented endoscopic surgery principles were applied and, in select cases where the tumour pedicle was located on the anterior wall, a modified endoscopic medial maxillectomy was carried out as described in this paper. From 2006 to 2014 a total of 84 patients were treated. A standard endoscopic medial maxillectomy was performed in 55 patients (65.4%), while the remaining 29 (34.6%) had a modified technique performed. Three recurrences (3/84; 3.6%) were observed after a minimum follow-up of 24 months. A new surgical approach for select cases of maxillary sinus inverted papilloma is proposed in this paper. In this technique, the endoscopic medial maxillectomy was performed while preserving the head of the inferior turbinate and the nasolacrimal duct ("TuNa-saving"). This technique allowed for good visualization of the maxillary sinus, good oncological control and a reduction in the rate of complications.

  6. A Non-invasive Real-time Localization System for Enhanced Efficacy in Nasogastric Intubation.

    PubMed

    Sun, Zhenglong; Foong, Shaohui; Maréchal, Luc; Tan, U-Xuan; Teo, Tee Hui; Shabbir, Asim

    2015-12-01

    Nasogastric (NG) intubation is one of the most commonly performed clinical procedures. Real-time localization and tracking of the NG tube passage at the larynx region into the esophagus is crucial for safety, but is lacking in current practice. In this paper, we present the design, analysis and evaluation of a non-invasive real-time localization system using passive magnetic tracking techniques to improve efficacy of the clinical NG intubation process. By embedding a small permanent magnet at the insertion tip of the NG tube, a wearable system containing embedded sensors around the neck can determine the absolute position of the NG tube inside the body in real-time to assist in insertion. In order to validate the feasibility of the proposed system in detecting erroneous tube placement, typical reference intubation trajectories are first analyzed using anatomically correct models and localization accuracy of the system are evaluated using a precise robotic platform. It is found that the root-mean-squared tracking accuracy is within 5.3 mm for both the esophagus and trachea intubation pathways. Experiments were also designed and performed to demonstrate that the system is capable of tracking the NG tube accurately in biological environments even in presence of stationary ferromagnetic objects (such as clinical instruments). With minimal physical modification to the NG tube and clinical process, this system allows accurate and efficient localization and confirmation of correct NG tube placement without supplemental radiographic methods which is considered the current clinical standard.

  7. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    NASA Astrophysics Data System (ADS)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  8. Device and Medication Preferences of Canadian Physicians for Emergent Endotracheal Intubation in Critically Ill Patients.

    PubMed

    Green, Robert S; Fergusson, Dean A; Turgeon, Alexis F; McIntyre, Lauralyn A; Kovacs, George J; Griesdale, Donald E; Zarychanski, Ryan; Butler, Michael B; Kureshi, Nelofar; Erdogan, Mete

    2017-05-01

    Various medications and devices are available for facilitation of emergent endotracheal intubations (EETIs). The objective of this study was to survey which medications and devices are being utilized for intubation by Canadian physicians. A clinical scenario-based survey was developed to determine which medications physicians would administer to facilitate EETI, their first choice of intubation device, and backup strategy should their first choice fail. The survey was distributed to Canadian emergency medicine (EM) and intensive care unit (ICU) physicians using web-based and postal methods. Physicians were asked questions based on three scenarios (trauma; pneumonia; heart failure) and responded using a 5-point scale ranging from "always" to "never" to capture usual practice. The survey response rate was 50.2% (882/1,758). Most physicians indicated a Macintosh blade with direct laryngoscopy would "always/often" be their first choice of intubation device in the three scenarios (mean 85% [79%-89%]) followed by video laryngoscopy (mean 37% [30%-49%]). The most common backup device chosen was an extraglottic device (mean 59% [56%-60%]). The medications most physicians would "always/often" administer were fentanyl (mean 45% [42%-51%]) and etomidate (mean 38% [25%-50%]). EM physicians were more likely than ICU physicians to paralyze patients for EETI (adjusted odds ratio 3.40; 95% CI 2.90-4.00). Most EM and ICU physicians utilize direct laryngoscopy with a Macintosh blade as a primary device for EETI and an extraglottic device as a backup strategy. This survey highlights variation in Canadian practice patterns for some aspects of intubation in critically ill patients.

  9. Desflurane or isoflurane for paediatric ENT anaesthesia. A comparison of intubating conditions and recovery profile.

    PubMed

    Wilhelm, W; Berner, K; Grundmann, U; Palz, M; Larsen, R

    1998-12-01

    The inhaled anaesthetic desflurane is characterized by a rapid wash-in and wash-out and may be useful for short paediatric ENT procedures. Therefore, this study was designed to compare the effects of desflurane or isoflurane on intubating conditions and recovery characteristics in paediatric ENT patients. In this prospective, randomised investigation, we studied 44 children scheduled for ENT surgery, aged 4-12 yr and classified ASA I-II. After thiopentone induction (5-8 mg/kg) the lungs were ventilated by face mask and the vaporizer was dialed to 1 MAC (age-adapted) of desflurane of isoflurane. A reduced dose of vecuronium (0.05 mg/kg) was administered, and intubating conditions were rated 3 min later. Following tracheal intubation, 50% nitrous oxide were added, and the concentration of desflurane or isoflurane was adjusted according to clinical needs. At the end of surgery all anaesthetics were discontinued simultaneously and recovery times were recorded. Intubating conditions were rated significantly better for desflurane (excellent or good 20 of 22) than for isoflurane (12 of 22). Recovery times were significantly shorter for desflurane than for isoflurane (mean +/- SE): spontaneous ventilation 4.0 +/- 0.5 min vs. 6.0 +/- 0.7 min, extubation 8.4 +/- 0.7 vs. 11.4 +/- 1.1 min and arrival at PACU 11.5 +/- 0.8 vs. 16.6 +/- 1.5 min. No airway complications (coughing, laryngospasm, or desaturation < 97%) were noted for either anaesthetic. Following an intravenous induction improved intubating conditions, shorter recovery times and the lack of airway complications make desflurane a suitable alternative to isoflurane for paediatric ENT anaesthesia.

  10. Dose of rocuronium for rapid tracheal intubation following remifentanil 2 μg kg-1 and propofol 2 mg kg-1.

    PubMed

    Oh, Ah-Young; Cho, Suk-Ju; Seo, Kwang-Suk; Ryu, Jung-Hee; Han, Sung-Hee; Hwang, Jung-Won

    2013-09-01

    Full relaxation is not mandatory for successful tracheal intubation. We tried to find the dose of rocuronium that gave acceptable intubation conditions in a rapid sequence intubation with remifentanil and propofol. A dose-finding study of rocuronium using a modified Dixon's up-and-down method. A single tertiary care teaching hospital. Patients undergoing elective surgery under general anaesthesia. After premedication with midazolam and glycopyrrolate, anaesthesia was induced using remifentanil 2 μg kg and propofol 2 mg kg, and a predetermined dose of rocuronium was administered. The dose of rocuronium was determined by a modified Dixon's up-and-down method starting from 0.8 mg kg with an interval of 0.1 or 0.05 mg kg. Intubation was performed 60 s after the start of the rocuronium injection. Intubation conditions were graded as excellent, good or poor. Excellent or good were regarded as clinically acceptable. A dose of rocuronium needed for acceptable intubation condition in 50% of patients (ED50) during rapid tracheal intubation after induction of anaesthesia with remifentanil and propofol. Twenty-eight patients were enrolled to obtain six crossovers. The ED50 of rocuronium was 0.20 mg kg (95% confidence interval, CI 0.17 to 0.23 mg kg) by a modified Dixon's up-and-down method. After induction of anaesthesia with remifentanil 2 μg kg and propofol 2 mg kg, the ED50 of rocuronium for acceptable intubation condition was 0.20 mg kg (95% CI, 0.17 to 0.23 mg kg) for rapid sequence intubation. Thus, we recommend that the intubation dose should be 0.8 mg kg. Clinical trial registration KCT0000094.

  11. Psychological traits influence autonomic nervous system recovery following esophageal intubation in health and functional chest pain.

    PubMed

    Farmer, A D; Coen, S J; Kano, M; Worthen, S F; Rossiter, H E; Navqi, H; Scott, S M; Furlong, P L; Aziz, Q

    2013-12-01

    Esophageal intubation is a widely utilized technique for a diverse array of physiological studies, activating a complex physiological response mediated, in part, by the autonomic nervous system (ANS). In order to determine the optimal time period after intubation when physiological observations should be recorded, it is important to know the duration of, and factors that influence, this ANS response, in both health and disease. Fifty healthy subjects (27 males, median age 31.9 years, range 20-53 years) and 20 patients with Rome III defined functional chest pain (nine male, median age of 38.7 years, range 28-59 years) had personality traits and anxiety measured. Subjects had heart rate (HR), blood pressure (BP), sympathetic (cardiac sympathetic index, CSI), and parasympathetic nervous system (cardiac vagal tone, CVT) parameters measured at baseline and in response to per nasum intubation with an esophageal catheter. CSI/CVT recovery was measured following esophageal intubation. In all subjects, esophageal intubation caused an elevation in HR, BP, CSI, and skin conductance response (SCR; all p < 0.0001) but concomitant CVT and cardiac sensitivity to the baroreflex (CSB) withdrawal (all p < 0.04). Multiple linear regression analysis demonstrated that longer CVT recovery times were independently associated with higher neuroticism (p < 0.001). Patients had prolonged CSI and CVT recovery times in comparison to healthy subjects (112.5 s vs 46.5 s, p = 0.0001 and 549 s vs 223.5 s, p = 0.0001, respectively). Esophageal intubation activates a flight/flight ANS response. Future studies should allow for at least 10 min of recovery time. Consideration should be given to psychological traits and disease status as these can influence recovery. © 2013 John Wiley & Sons Ltd.

  12. Comparison of the Pentax, Truview, GlideScope, and the Miller laryngoscope for child intubation during resuscitation.

    PubMed

    Szarpak, Łukasz; Czyżewski, Łukasz; Kurowski, Andrzej

    2015-03-01

    The study was designed to compare the effectiveness of 3 video laryngoscopes with the Miller laryngoscope during pediatric resuscitation. This was a randomized crossover study involving 87 paramedics and 54 nurses. The primary end point of the study was the success rate of blind tracheal intubation, whereas the secondary end point was defined as the time from insertion of a device to the first manual ventilation of the manikin's lungs. The median time to intubation using the Pentax, Truview, GlideScope, and Miller varied with the times being 20.6 (interquartile range [IQR], 18-27) vs 20.1 (IQR, 18-23.3) vs 30.2 (IQR, 29.6-35) vs 41.3 (IQR, 33-45.2) seconds, respectively. The overall success ratios of intubation for the devices were 100% vs 100% vs 100% vs 79.4%. We concluded that, in a pediatric manikin scenario, the video laryngoscopes are safe devices and can be used for pediatric intubation during uninterrupted chest compressions. Further clinical studies are necessary to confirm these initial positive findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Long term intubation and successful weaning in two children with Guillain-Barre syndrome.

    PubMed

    Javed, H; Nair, M P; Koul, R L; Chacko, A; Fazalullah, M

    2000-07-01

    No definite criteria exists in Guillian-Barre syndrome in children regarding prolonged ventilation through an endo-tracheal tube without tracheostomy and successful weaning using a T-piece. Here we report two such cases of Guillian-Barre syndrome requiring prolonged intubation for 56 days and ventilation for 30 days and ultimately successfully weaning them using the T-piece. Both the children eventually made a complete recovery, highlighting the point that in children prolonged intubation and ventilation using the portex tube is equally good, if not, better than tracheostomy with its attendant risks.

  14. Convolution seal for transition duct in turbine system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston

    2015-03-10

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a convolution seal contacting the interface member to provide a seal between the interface member and themore » turbine section.« less

  15. Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program

    NASA Technical Reports Server (NTRS)

    Beckemeyer, R. J.; Sawdy, D. T.

    1971-01-01

    An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.

  16. [Bile duct lesions in laparoscopic cholecystectomy].

    PubMed

    Siewert, J R; Ungeheuer, A; Feussner, H

    1994-09-01

    Laparoscopic cholecystectomy is both resulting in a slightly higher incidence of biliary lesions and a change of prevalence of the type of lesions. Damage to the biliary system occurs in 4 different types: The most severe case is the lesion with a structural defect of the hepatic or common bile duct with (IVa) or without (IVb) vascular injury. Tangential lesions without structural loss of the duct should be denominated as type III (IIIa with additional lesion to the vessels, type IIIb without). Type II comprehends late strictures without obvious intraoperative trauma to the duct. Type I includes immediate biliary fistulae of usually good prognosis. The increasing prevalence of structural defects of the bile ducts appears to be a peculiarity of laparoscopic cholecystectomy necessitating highly demanding operative repair. In the majority of cases, hepatico-jejunostomy or even intraparenchymatous anastomoses are required. Adaptation of well proven principles of open surgery is the best prevention of biliary lesions in laparoscopic cholecystectomy as well as the readiness to convert early to the open procedure.

  17. Prehospital Endotracheal Intubation in Warm Climates: Caution is Required.

    PubMed

    Daniel, Yann; Habas, Sébastien; Cruc, Maximilien

    2016-09-01

    Out-of-hospital endotracheal intubation is a frequent procedure for trauma care. Nevertheless, in warm climates, sunlight and heat can interfere with the flow of the usual procedure. They can affect the equipment and hinder the operator. There are few data on this issue. The presentation of this case highlights three common complications that may occur when intubating under a hot and bright sun. A 23-year-old man had a car accident in Djibouti, at 11:00 a.m., in broad sunlight. The heat was scorching. Due to a severe head trauma, with a Glasgow Coma Scale score of 8, it was decided to perform an endotracheal intubation. The operator faced three problems: the difficulty of seeing inside the mouth in the bright sunlight, the softening of the tube under the influence of the heat, and the inefficiency of colorimetric CO2 detectors in the warm atmosphere in confirming the proper endotracheal tube placement. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Solutions are simple, but must be known and planned ahead, prior to beginning the procedure: Putting a jacket over his head while doing the laryngoscopy would solve the problem of dazzle; adjuncts like a stylet or gum elastic bougie have to be used at the outset to fix the softening problem; alternative methods to exhaled CO2 detection, such as the syringe aspiration technique, to confirm the proper tube placement, should be available. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    DTIC Science & Technology

    2016-09-01

    material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is

  19. Measure Guideline: Buried and/or Encapsulated Ducts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, C.; Zoeller, W.; Mantha, P.

    2013-08-01

    Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. This Building America Measure Guideline synthesizes previouslymore » published research on BEDs and provides practical information to builders, contractors, homeowners, policy analysts, building professions, and building scientists. Some of the procedures presented here, however, require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license. Persons implementing duct system improvements should not go beyond their expertise or qualifications. This guideline provides valuable information for a building industry that has struggled to address ductwork thermal losses in new and existing homes. As building codes strengthen requirements for duct air sealing and insulation, flexibility is needed to address energy efficiency goals. While ductwork in conditioned spaces has been promoted as the panacea for addressing ductwork thermal losses, BEDs installations approach - and sometimes exceed - the performance of ductwork in conditioned spaces.« less

  20. Acoustic energy in ducts - Further observations

    NASA Technical Reports Server (NTRS)

    Eversman, W.

    1979-01-01

    The transmission of acoustic energy in uniform ducts carrying uniform flow is investigated with the purpose of clarifying two points of interest. The two commonly used definitions of acoustic 'energy' flux are shown to be related by a Legendre transformation of the Lagrangian density exactly as in deriving the Hamiltonian density in mechanics. In the acoustic case the total energy density and the Hamiltonian density are not the same which accounts for two different 'energy' fluxes. When the duct has acoustically absorptive walls neither of the two flux expressions gives correct results. A reevaluation of the basis of derivation of the energy density and energy flux provides forms which yield consistent results for soft walled ducts.

  1. Characterization of flow in a scroll duct

    NASA Technical Reports Server (NTRS)

    Begg, E. K.; Bennett, J. C.

    1985-01-01

    A quantitative, flow visualization study was made of a partially elliptic cross section, inward curving duct (scroll duct), with an axial outflow through a vaneless annular cutlet. The working fluid was water, with a Re(d) of 40,000 at the inlet to the scroll duct, this Reynolds number being representative of the conditions in an actual gas turbine scroll. Both still and high speed moving pictures of fluorescein dye injected into the flow and illuminated by an argon ion laser were used to document the flow. Strong secondary flow, similar to the secondary flow in a pipe bend, was found in the bottom half of the scroll within the first 180 degs of turning. The pressure field set up by the turning duct was strong enough to affect the inlet flow condition. At 90 degs downstream, the large scale secondary flow was found to be oscillatory in nature. The exit flow was nonuniform in the annular exit. By 270 degs downstream, the flow appeared unorganized with no distinctive secondary flow pattern. Large scale structures from the upstream core region appeared by 90 degs and continued through the duct to reenter at the inlet section.

  2. Intubating conditions and side effects of propofol, remifentanil and sevoflurane compared with propofol, remifentanil and rocuronium: a randomised, prospective, clinical trial

    PubMed Central

    2014-01-01

    Background Tracheal intubation without muscle relaxants is usually performed with remifentanil and propofol or sevoflurane. Remifentanil 1.0 to 4.0 μg·kg-1 and propofol 2.0-3.0 mg·kg-1 or sevoflurane up to 8.0 Vol% provide acceptable, i.e. excellent or good intubating conditions. We hypothesized that sevoflurane 1.0 MAC would provide acceptable intubating conditions when combined with propofol and remifentanil. Methods Eighty-three patients to be intubated were randomised to two groups. The SEVO group received propofol 1.5 mg kg-1, remifentanil 0.30 μg kg min-1 and sevoflurane 1.0 MAC; the MR group received the same doses of propofol and remifentanil plus rocuronium 0.45 mg kg-1. We evaluated intubation and extubation conditions, mean arterial pressure (MAP), heart rate (HR) and bispectral index (BIS). The vocal cords were examined for injury by videolaryngoscopy before and 24 hours after surgery. Results Acceptable intubating conditions were seen more frequently with rocuronium than with sevoflurane: 97% versus 82%; p = 0.03; the subscore for vocal cords was comparable: 100% versus 98%. MAP before intubation decreased significantly compared with the MAP at baseline to the same extent in both groups; ephedrine IV was given in 15 (SEVO) versus 16 (MR) patients; p = 0.93. BIS at tracheal intubation was 27 (13-65) in the SEVO group, 29 (14-62) in the MR group; p = 0.07. Vocal cord injuries (oedema, haematoma) were similar: 4 patients in each group. Conclusions Overall intubating conditions were better when rocuronium was used; the subscore for vocal cords was comparable. The incidence of side effects was the same in the two groups. Trial registration ClinicalTrials.Gov: NCT 01591031. PMID:24860256

  3. A Randomized Study Comparing the Sniffing Position with Simple Head Extension for Glottis Visualization and Difficulty in Intubation during Direct Laryngoscopy.

    PubMed

    Akhtar, Mehmooda; Ali, Zulfiqar; Hassan, Nelofar; Mehdi, Saqib; Wani, Gh Mohammad; Mir, Aabid Hussain

    2017-01-01

    Proper positioning of the head and neck is important for an optimal laryngeal visualization. Traditionally, sniffing position (SP) is recommended to provide a superior glottic visualization, during direct laryngoscopy, enhancing the ease of intubation. Various studies in the last decade of this belief have challenged the need for sniffing position during intubation. We conducted a prospective study comparing the sniffing head position with simple head extension to study the laryngoscopic view and intubation difficulty during direct laryngoscopy. Five-hundred patients were included in this study and randomly distributed to SP or simple head extension. In the sniffing group, an incompressible head ring was placed under the head to raise its height by 7 cm from the neutral plane followed by maximal extension of the head. In the simple extension group, no headrest was placed under the head; however, maximal head extension was given at the time of laryngoscopy. Various factors as ability to mask ventilate, laryngoscopic visualization, intubation difficulty, and posture of the anesthesiologist during laryngoscopy and tracheal intubation were noted. In the incidence of difficult laryngoscopy (Cormack Grade III and IV), Intubation Difficulty Scale (IDS score) was compared between the two groups. There was no significant difference between two groups in Cormack grades. The IDS score differed significantly between sniffing group and simple extension group ( P = 0.000) with an increased difficulty during intubation in the simple head extension. Patients with simple head extension needed more lifting force, increased use of external laryngeal manipulation, and an increased use of alternate techniques during intubation when compared to SP. We conclude that compared to the simple head extension position, the SP should be used as a standard head position for intubation attempts under general anesthesia.

  4. Effect of just-in-time simulation training on tracheal intubation procedure safety in the pediatric intensive care unit.

    PubMed

    Nishisaki, Akira; Donoghue, Aaron J; Colborn, Shawn; Watson, Christine; Meyer, Andrew; Brown, Calvin A; Helfaer, Mark A; Walls, Ron M; Nadkarni, Vinay M

    2010-07-01

    Tracheal intubation-associated events (TIAEs) are common (20%) and life threatening (4%) in pediatric intensive care units. Physician trainees are required to learn tracheal intubation during intensive care unit rotations. The authors hypothesized that "just-in-time" simulation-based intubation refresher training would improve resident participation, success, and decrease TIAEs. For 14 months, one of two on-call residents, nurses, and respiratory therapists received 20-min multidisciplinary simulation-based tracheal intubation training and 10-min resident skill refresher training at the beginning of their on-call period in addition to routine residency education. The rate of first attempt and overall success between refresher-trained and concurrent non-refresher-trained residents (controls) during the intervention phase was compared. The incidence of TIAEs between preintervention and intervention phase was also compared. Four hundred one consecutive primary orotracheal intubations were evaluated: 220 preintervention and 181 intervention. During intervention phase, neither first-attempt success nor overall success rate differed between refresher-trained residents versus concurrent non-refresher-trained residents: 20 of 40 (50%) versus 15 of 24 (62.5%), P = 0.44 and 23 of 40 (57.5%) versus 18 of 24 (75.0%), P = 0.19, respectively. The resident's first attempt and overall success rate did not differ between preintervention and intervention phases. The incidence of TIAE during preintervention and intervention phases was similar: 22.0% preintervention versus 19.9% intervention, P = 0.62, whereas resident participation increased from 20.9% preintervention to 35.4% intervention, P = 0.002. Resident participation continued to be associated with TIAE even after adjusting for the phase and difficult airway condition: odds ratio 2.22 (95% CI 1.28-3.87, P = 0.005). Brief just-in-time multidisciplinary simulation-based intubation refresher training did not improve the resident

  5. Endotracheal intubation - A life saving procedure, still potential hazardous to upper airway: A case report.

    PubMed

    Afreen, Mahrukh; Ansari, Murtaza Ahsan

    2015-12-01

    Endotracheal intubation plays a key role in the management of upper airway obstruction in emergency situations. It is non-invasive and easily learned technique by medical professionals as compared to other more skilled, surgical procedures, e.g., tracheostomy and cricothyrotomies etc. But prolonged intubation may result in numerous complications, most notorious being tracheoesophageal fistula and narrowing of subglottic area. We report a profile of a patient who had been diagnosed as case of Guillian-Barre Syndrome, had difficulty in breathing due to paralysis of respiratory muscles. The patient was admitted in Medical Intensive Care Unit (MICU) for 40 days and was kept on artificial breathing through endotracheal intubation, which remained in place for 19 days. Later tracheostomy was performed. Patient ultimately developed severe subglottic stenosis and became dependent on tracheostomy tube.

  6. Double silicone tube intubation for the management of partial lacrimal system obstruction.

    PubMed

    Demirci, Hakan; Elner, Victor M

    2008-02-01

    To evaluate the effectiveness of double silicone intubation for the management of partial lacrimal drainage system obstruction in adults. Observational retrospective case series. Twenty-four eyes of 18 consecutive adult patients with partial lacrimal system obstruction managed at the University of Michigan. Retrospective review of symptoms and signs, duration of silicone intubation, and complications. Resolution of tearing. Preoperative tearing, negative Jones I testing, positive Jones II testing, and resistance to positive-pressure irrigation were present in all eyes (100%). The first silicone tube was removed after a mean of 11+/-7 months, and the second tube after 16+/-6 months. Postoperatively, at a mean of 21+/-9 months after removal of both tubes, tearing remained resolved in 19 eyes (79%) and remained improved in 2 eyes (8%). In eyes with resolved tearing, Jones I testing became positive, and there was no resistance to positive-pressure irrigation. Persistent tearing in 3 eyes (13%) required treatment with external dacryocystorhinostomy. The only complication was peripunctal pyogenic granulomas in 2 eyes. Double silicone intubation is an effective minimally invasive technique for treatment of partial lacrimal system obstruction in adults.

  7. Quality control in QuantiFERON-TB gold in-tube for screening latent tuberculosis infection in health care workers.

    PubMed

    Igari, Hidetoshi; Watanabe, Akira; Ichimura, Yasunori; Sakurai, Takayuki; Taniguchi, Toshibumi; Ishiwada, Naruhiko

    2017-04-01

    QuantiFERON-TB gold in-tube has been used for screening latent tuberculosis infection in newly employed health care workers in Japan. There have been a few studies concerning quality control. We retrospectively analysed QuantiFERON-TB gold in-tube results in a hospital in Japan. Interferon-γ values in three blood collection tubes for QuantiFERON-TB gold in-tube were analysed in association with the positivity rate. The data set consisted of health care workers aged 20-29 years during the 7 years between 2010 and 2016. The yearly QuantiFERON-TB gold in-tube positivity rate was 0.9%, 16.4%, 3.0%, 39.3%, 2.8%, 0.9% and 1.5%, and was extremely high in 2011 and 2013. The interferon-γ values in the tuberculosis antigen tube were elevated in these two years, as indicated by higher median and wider interquartile range. The interferon-γ value in the negative control tube was also higher in 2011. The higher interferon-γ values in collection tubes (tuberculosis antigen tube and/or negative control tube) resulted in higher QuantiFERON-TB gold in-tube positivity rate. The distribution of interferon-γ in tuberculosis antigen tube and negative control tube, as evaluated by median and interquartile range, proved to be an effective index for the quality control of QuantiFERON-TB gold in-tube. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  8. Straight video blades are advantageous than curved blades in simulated pediatric difficult intubation.

    PubMed

    Saracoglu, Kemal T; Eti, Zeynep; Kavas, Ayse D; Umuroglu, Tumay

    2014-03-01

    It is still controversial which laryngoscope may be a better option in unanticipated difficult airway in pediatric patients. The aim of the present study was to compare two direct and two video-assisted laryngoscope devices for the management of difficult pediatric airway. Forty-five anesthesiology residents and nurse anesthetists participated in the study. Macintosh, Miller, Storz Miller, and McGrath Mac curved laryngoscopes were used for tracheal intubation of 3-6-month Airsim Pierre Robin manikin. We compared the duration of successful intubation, number of attempts, glottic view grades, severity of dental trauma, the use of optimization maneuvers, and the difficulty of use of the devices with straight and curved laryngoscope blades. Successful intubation duration was significantly lower in Storz Miller device, and the number of intubation attempts was significantly higher in the Macintosh laryngoscope (P < 0.01). According to the Cormack and Lehane classification, Grades 1 and 2 glottic view was 20% for Macintosh and 40% for Miller laryngoscope, while it was 100% for Storz Miller and 80% for McGrath (P < 0.001). Difficulty VAS scores of Storz Miller device were significantly lower than the scores of Macintosh, Miller, and McGrath laryngoscopes (15.7 ± 14.89, 34.7 ± 26.44, 31.5 ± 26.74, 33.4 ± 26.67 mm, respectively; P < 0.01). The severity of dental trauma was significantly lower in Storz Miller compared with Macintosh, Miller, and McGrath laryngoscopes (0.96 ± 1.04, 1.67 ± 1.15, 1.38 ± 1.05, 1.42 ± 1.27, respectively; P < 0.01). Storz Miller laryngoscope was found to have advantages over the other laryngoscopes in regard to glottic view, duration of successful intubation, number of attempts, dental trauma severity, need for additional maneuvers, and ease of use. © 2013 John Wiley & Sons Ltd.

  9. Pipe crawler development for duct elbow removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zollinger, W.T.; Treanor, R.C.

    1992-01-01

    This paper describes the development of equipment for removing an elbow in a 36 inch diameter ventilation line by cutting from the inside. Radiation levels, high air flow and physical constraints preclude any manual rework of the ventilation system. A remotely operated pipe crawler was developed. Testing has been performed in a full-scale mockup which models the ventilation duct configuration with the exception of radiation levels. The results gathered from the testing are discussed, and illustrate the strengths and weaknesses of the crawler and plasma arc torch system. To date, the equipment has successfully completed the tasks of maneuvering throughmore » the duct geometry, performing the two required cuts, and backing out of the duct mockup. The elbow successfully fell away from the main duct, showing that the line would be clear of obstructions.« less

  10. Pipe crawler development for duct elbow removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zollinger, W.T.; Treanor, R.C.

    1992-11-01

    This paper describes the development of equipment for removing an elbow in a 36 inch diameter ventilation line by cutting from the inside. Radiation levels, high air flow and physical constraints preclude any manual rework of the ventilation system. A remotely operated pipe crawler was developed. Testing has been performed in a full-scale mockup which models the ventilation duct configuration with the exception of radiation levels. The results gathered from the testing are discussed, and illustrate the strengths and weaknesses of the crawler and plasma arc torch system. To date, the equipment has successfully completed the tasks of maneuvering throughmore » the duct geometry, performing the two required cuts, and backing out of the duct mockup. The elbow successfully fell away from the main duct, showing that the line would be clear of obstructions.« less

  11. [Bile duct lesions repaired with peritoneal tube grafts].

    PubMed

    Lorenzana-Bautista, Ileana; Flores-Plascencia, Aníbal; Barrios-Pineda, Francisco Javier; Alderete-Vázquez, Georgia; Sánchez-Valdivieso, Enrique Alejandro

    2013-01-01

    A significant number of people suffer iatrogenic bile duct injury during laparoscopic cholescystectomy. Biliary-digestive bypass may be complicated by stenosis and biliary sepsis, affecting both quality of life and life expectancy. To avoid bypass synthetic grafts have been used, which are expensive. Evaluating autologous implantation of peritoneus as alternative of bile duct repair. Under general anesthesia, ten New Zealand adult rabbits were operated, common bile duct approached and sectioned underneath the cystic duct followed by a liver biopsy. An autologous graft was built of peritoneum and graft-bile duct proximal and distal end-to-end anastomosis done. Animals were followed-up by weekly bilirrubin and transferases. Rabbits were scheduled euthanized and a liver biopsy done for histological examinations. Autologous graft was easy to create and all rabbits survived. They did not develop jaundice or alterations in their normal habits. At necropsy, autologous grafts were removed and no signs of occlusion were noticed. Moderate short-term liver damage was observed but long-term damage was negligible. Bileoma and pyogenic liver abscess were observed in two animals, respectively. Our results favourably match well-known procedures used for bile duct repair, especially in cases of severe injury (Bismuth-Strasberg E1-3): it seems less complicated than biliary-digestive bypass, not as expensive as synthetic grafts, and much easier to build than human amnion graft. Interposing an autologous graft of peritoneum is an easy-to-create surgical procedure and circumferential bile duct injuries were adequately repaired.

  12. Tracheal intubation in the ice-pick position with video laryngoscopes: a randomised controlled trial in a manikin.

    PubMed

    Wetsch, Wolfgang A; Hellmich, Martin; Spelten, Oliver; Schier, Robert; Böttiger, Bernd W; Hinkelbein, Jochen

    2013-09-01

    Tracheal intubation in nonstandardised positions is associated with a higher risk of tube misplacement and may have deleterious consequences for patients. Video laryngoscopes for tracheal intubation facilitate both glottic view and success rates. However, their use in the ice-pick position has not been evaluated. To evaluate the role of video laryngoscopes for tracheal intubation in the ice-pick position. A randomised, controlled manikin trial. A standardised airway manikin was placed in the corner of a room. Tracheal intubation was only possible from the lower right side of the manikin. In randomised order, participants used a standard Macintosh laryngoscope and GlideScope Ranger, Storz C-MAC, Pentax AWS, Airtraq and McGrath Series5 video laryngoscopes. Statistical analysis was performed using the Wilcoxon signed-rank and McNemar's tests; A P value of less than 0.05 was deemed statistically significant. Twenty anaesthesiologists, all emergency medicine board-certified. Time to first ventilation (primary); time to glottic view and confirmation of tube position (secondary). Successful ventilation was achieved most rapidly with the Macintosh laryngoscope (36.1 ± 13.4 s; reference method), followed by the Airtraq (38.4 ± 36.3 s; P = n.s.), Pentax AWS (51.6 ± 43.3 s; P = n.s.) and Storz C-Mac (62.7 ± 49.7 s; P = n.s.). The use of the GlideScope Ranger (79.8 ± 61.9 s, P = 0.01) and McGrath series5 (79.8 ± 58.5 s, P = 0.023) resulted in significantly longer times. When comparing overall intubation success, the rate of successful tracheal intubation was higher with the Airtraq than with the McGrath Series5 (P = 0.031; all others n.s.). The use of video laryngoscopes did not result in higher success rates or faster tracheal intubation in the ice-pick position when compared with conventional laryngoscopy in this manikin study. www.clinicaltrials.gov, NCT01210105.

  13. Borescope Device Takes Impressions In Ducts

    NASA Technical Reports Server (NTRS)

    Walter, Richard F.; Turner, Laura J.

    1990-01-01

    Maneuverable device built around borescope equipped to make impression molds of welded joints in interior surfaces of ducts. Molds then examined to determine degress of mismatch in welds. Inserted in duct, and color-coded handles on ends of cables used to articulate head to maneuver around corners. Use of device fairly easy and requires little training.

  14. A non-local computational boundary condition for duct acoustics

    NASA Technical Reports Server (NTRS)

    Zorumski, William E.; Watson, Willie R.; Hodge, Steve L.

    1994-01-01

    A non-local boundary condition is formulated for acoustic waves in ducts without flow. The ducts are two dimensional with constant area, but with variable impedance wall lining. Extension of the formulation to three dimensional and variable area ducts is straightforward in principle, but requires significantly more computation. The boundary condition simulates a nonreflecting wave field in an infinite duct. It is implemented by a constant matrix operator which is applied at the boundary of the computational domain. An efficient computational solution scheme is developed which allows calculations for high frequencies and long duct lengths. This computational solution utilizes the boundary condition to limit the computational space while preserving the radiation boundary condition. The boundary condition is tested for several sources. It is demonstrated that the boundary condition can be applied close to the sound sources, rendering the computational domain small. Computational solutions with the new non-local boundary condition are shown to be consistent with the known solutions for nonreflecting wavefields in an infinite uniform duct.

  15. The punctal apposition syndrome: a new surgical approach.

    PubMed

    Francis, I C; Wan, M K

    2002-11-01

    To assess the punctal apposition syndrome (PAS) and its response to lateral canthal tendon (LCT) repair. In this retrospective, interventional case series, five patients (seven symptomatic eyes) with PAS were managed. Lateral canthal tendon repair was performed in all seven eyes. The main outcome measure was correction of watery eye symptomatology. All five patients achieved symptomatic resolution. Conjunctivochalasis and functional nasolacrimal duct obstruction were associated with the PAS. This new surgical approach to the PAS, using a LCT repair, was successful in all patients. Two patients (three eyes) required conjunctivochalasis excision.

  16. Generalized osteosclerosis in a cat.

    PubMed

    Hanel, Rita M; Graham, John P; Levy, Julie K; Buergelt, Claus D; Creamer, Jeff

    2004-01-01

    A 12-year-old, neutered male, domestic long-hair cat was evaluated for a 6-month history of inspiratory stertor and epiphora. In computed tomography of the skull and pelvis, and radiographs of the thorax, right femur and stifle there was generalized osteosclerosis, with obliteration of the nasal turbinates and nasolacrimal duct obstruction. The cat also had a large fibrosarcoma involving the right pelvic limb. Osteosclerosis is a rare disorder that is poorly understood but has been described in several species. Various manifestations, potential causes, and radiologic findings of osteosclerosis are discussed.

  17. On Computations of Duct Acoustics with Near Cut-Off Frequency

    NASA Technical Reports Server (NTRS)

    Dong, Thomas Z.; Povinelli, Louis A.

    1997-01-01

    The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.

  18. Bile duct injury during cholecystectomy.

    PubMed

    Kapoor, V K

    2015-08-01

    Laparoscopic cholecystectomy (LC) is the treatment of choice for gallstones, but is associated with increased risk of bile duct injury (BDI bile duct injury). If the BDI is detected during LC can be addressed immediately, if available hepatobiliary surgeon, but the easiest and safest procedure for the general surgeon is placing drains into subhepatic region and the transfer of acute BDI to controlled external biliary fistula (external Biliary fistula EBF). Most BDI is diagnosed when the postoperative period, when there is biliary leak. Therapy is a percutaneous catheter drainage and endoscopic stenting in the bile duct; early repair is not recommended. Repair in the form hepatico-jejunostomy (HJ) should be performed hepatobiliary surgeon at intervals of 46 weeks after it closes EBF. BDI is a frequent cause medico-legal actions and a substantial burden on health care costs. Most BDI can be avoided by adherence to the principles of safe cholecystectomy.

  19. Mayo registry for telemetry efficacy in arrest study: An evaluation of the feasibility of the do not intubate code status.

    PubMed

    Snipelisky, David; Dumitrascu, Adrian; Ray, Jordan; Roy, Archana; Matcha, Gautam; Harris, Dana; Vadeboncoeur, Tyler; Kusumoto, Fred; Burton, M Caroline

    2017-12-06

    Guidelines recommend discussing code status with patients on hospital admission. No study has evaluated the feasibility of a full code with do not intubate (DNI) status. A retrospective analysis of patients who experienced a cardiopulmonary arrest was performed between May 1, 2008 and June 20, 2014. A descriptive analysis was created based on whether patients required mechanical ventilatory support during the hospitalization and comparisons were made between both patient subsets. A total of 239 patients were included. Almost all (n = 218, 91.2%) required intubation during the hospitalization. Over half (n = 117, 53.7%) were intubated on the same day as the cardiopulmonary arrest and 91 patients (41.7%) were intubated at the time of arrest. Comparisons between intubated and non-intubated patients showed little differences in clinical characteristics, except for a higher proportion of medical cardiac etiology for admission in patients who did not require intubation (n = 10, 47.6% versus n = 55, 25.2%; p = 0.18) and initial arrest rhythm of ventricular tachycardia/fibrillation (n = 8, 38.1% versus n = 50, 22.9%; p = 0.37). No differences in 24-hour and posthospital survivals were present. Mechanical ventilatory support is commonly utilized in patients who experience a cardiopulmonary arrest. The DNI status may not be a feasible code status option for most patients.

  20. [Predictive value of preoperative tests in estimating difficult intubation in patients who underwent direct laryngoscopy in ear, nose, and throat surgery].

    PubMed

    Karakus, Osman; Kaya, Cengiz; Ustun, Faik Emre; Koksal, Ersin; Ustun, Yasemin Burcu

    2015-01-01

    Predictive value of preoperative tests in estimating difficult intubation may differ in the laryngeal pathologies. Patients who had undergone direct laryngoscopy (DL) were reviewed, and predictive value of preoperative tests in estimating difficult intubation was investigated. Preoperative, and intraoperative anesthesia record forms, and computerized system of the hospital were screened. A total of 2611 patients were assessed. In 7.4% of the patients, difficult intubations were detected. Difficult intubations were encountered in some of the patients with Mallampati scoring (MS) system Class 4 (50%), Cormack-Lehane classification (CLS) Grade 4 (95.7%), previous knowledge of difficult airway (86.2%), restricted neck movements (cervical ROM) (75.8%), short thyromental distance (TMD) (81.6%), vocal cord mass (49.5%) as indicated in parentheses (p<0.0001). MS had a low sensitivity, while restricted cervical ROM, presence of a vocal cord mass, short thyromental distance, and MS each had a relatively higher positive predictive value. Incidence of difficult intubations increased 6.159 and 1.736-fold with each level of increase in CLS grade and MS class, respectively. When all tests were considered in combination difficult intubation could be classified accurately in 96.3% of the cases. Test results predicting difficult intubations in cases with DL had observedly overlapped with the results provided in the literature for the patient populations in general. Differences in some test results when compared with those of the general population might stem from the concomitant underlying laryngeal pathological conditions in patient populations with difficult intubation. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  1. Comparison of blind intubation through the I-gel and ILMA Fastrach by nurses during cardiopulmonary resuscitation: a manikin study.

    PubMed

    Melissopoulou, Theodora; Stroumpoulis, Konstantinos; Sampanis, Michail A; Vrachnis, Nikolaos; Papadopoulos, Georgios; Chalkias, Athanasios; Xanthos, Theodoros

    2014-01-01

    To investigate whether nursing staff can successfully use the I-gel and the intubating laryngeal mask Fastrach (ILMA) during cardiopulmonary resuscitation. Although tracheal intubation is considered to be the optimal method for securing the airway during cardiopulmonary resuscitation, laryngoscopy requires a high level of skill. Forty five nurses inserted the I-gel and the ILMA in a manikin, with continuous and without chest compressions. Mean intubation times for the ILMA and I-gel without chest compressions were 20.60 ± 3.27 and 18.40 ± 3.26 s, respectively (p < 0.0005). ILMA proved more successful than the I-gel regardless of compressions. Continuation of compressions caused a prolongation in intubation times for both the I-gel (p < 0.0005) and the ILMA (p < 0.0005). In this mannequin study, nursing staff can successfully intubate using the I-gel and the ILMA as conduits with comparable success rates, regardless of whether chest compressions are interrupted or not. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. DUCT RETROFIT STRATEGY TO COMPLEMENT A MODULATING FURNACE.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ANDREWS,J.W.

    2002-10-02

    Some recent work (Walker 2001, Andrews 2002) has indicated that installing a modulating furnace in a conventional duct system may, in many cases, result in a significant degradation in thermal distribution efficiency. The fundamental mechanism was pointed out nearly two decades ago (Andrews and Krajewski 1985). The problem occurs in duct systems that are less-than-perfectly insulated (e.g., R-4 duct wrap) and are located outside the conditioned space. It stems from the fact that when the airflow rate is reduced, as it will be when the modulating furnace reduces its heat output rate, the supply air will have a longer residencemore » time in the ducts and will therefore lose a greater percentage of its heat by conduction than it did at the higher airflow rate. The impact of duct leakage, on the other hand, is not expected to change very much under furnace modulation. The pressures in the duct system will be reduced when the airflow rate is reduced, thus reducing the leakage per unit time. This is balanced by the fact that the operating time will increase in order to meet the same heating load as with the conventional furnace operating at higher output and airflow rates. The balance would be exact if the exponent in the pressure vs. airflow equation were the same as that in the pressure vs. duct leakage equation. Since the pressure-airflow exponent is usually {approx}0.5 and the pressure-leakage exponent is usually {approx}0.6, the leakage loss as a fraction of the load should be slightly lower for the modulating furnace. The difference, however, is expected to be small, determined as it is by a function with an exponent equal to the difference between the above two exponents, or {approx}0.1. The negative impact of increased thermal conduction losses from the duct system may be partially offset by improved efficiency of the modulating furnace itself. Also, the modulating furnace will cycle on and off less often than a single-capacity model, and this may add a small

  3. Nasal high-flow oxygen therapy improves arterial oxygenation during one-lung ventilation in non-intubated thoracoscopic surgery.

    PubMed

    Wang, Man-Ling; Hung, Ming-Hui; Chen, Jin-Shing; Hsu, Hsao-Hsun; Cheng, Ya-Jung

    2018-05-01

    Intraoperative hypoxaemia during one-lung ventilation (OLV) remains a major concern in thoracic surgery. Non-intubated video-assisted thoracic surgery (VATS) involves a greater risk of consequent emergent conversion to endotracheal intubation. Transnasal humidified rapid-insufflation ventilatory exchange (THRIVE) has recently been reported to be beneficial for higher oxygen reserves during difficult intubations and for enhancing postoperative recovery after thoracic surgery. However, the effects of THRIVE on oxygenation and carbon dioxide elimination before and during OLV in non-intubated VATS have not been investigated. Between September 2016 and October 2016, 30 patients underwent non-intubated VATS for lung tumour and were maintained with THRIVE at a flow of 20 l/min. These patients were compared with a historical control group comprising 30 patients who were maintained with oxygen masks at an oxygen flow of 10 l/min using a propensity score matching algorithm between September 2015 and July 2016. The preoperative arterial oxygen tension was significantly higher in patients maintained with THRIVE than it was in patients maintained with oxygen masks (mean 416.0 vs 265.9 mmHg, P < 0.01). During OLV, arterial oxygen tension remained significantly higher in the THRIVE group than in the oxygen mask group (mean 207.0 vs 127.8 mmHg, P = 0.01). The arterial carbon dioxide tension was comparable before and during OLV. The results indicated that THRIVE effectively increases the oxygen reserve both during OLV and after anaesthesia. Furthermore, non-intubated VATS is safer if THRIVE with flow adjustment is incorporated into a minimally invasive surgical approach, although carbon dioxide elimination is not facilitated.

  4. Usefulness and diagnostic value of the NEMA parameter combined with other selected bedside tests for prediction of difficult intubation.

    PubMed

    Torres, Kamil; Błoński, Marcin; Pietrzyk, Łukasz; Piasecka-Twaróg, Małgorzata; Maciejewski, Ryszard; Torres, Anna

    2017-02-01

    To assess the usefulness of the new NEMA (Neck Circumference Minus Acromion-Acromion Distance) parameter, in preoperative identification of patients' difficult intubation and compare it with other commonly used scales and tests. Prospective study. District Specialist Hospital of Lublin, Poland. Six hundreds twenty-nine patients underwent nonemergency surgical interventions. The NEMA parameter was confronted with: Modified Mallampati classification, TMD, RHTMD, NC, MPND, SMD, I-I D, A-AD, and medical history of difficult intubation and diagnosed obstructive sleep apnea syndrome or snoring. Higher medians of NEMA and Mallampati parameters were reported in patients with difficult intubation. AUC for Mallampati parameter was 0.733 while the NEMA parameter's AUC was 0.625. Sensitivity and specificity for Mallampati and NEMA parameter were respectively 0.79; 0.55 and 0.42; 0.75. Significantly higher MPN, RHTMD, Mallampati, and NEMA parameter were observed in patients in whom the BURP was used. Easy intubation occurs more frequently in patients with a history of OSAS or snoring than in those with difficult intubation. It seems that none of the known bedside tests for predicting difficult intubation have a discriminating power sufficient for clinicians. Our study draws attention to a novel parameter, called NEMA, which appears to be a strong predictor of DEI, especially in combination with the Mallampati scale. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Effect of prophylactic bronchodilator treatment with intravenous colforsin daropate, a water-soluble forskolin derivative, on airway resistance after tracheal intubation.

    PubMed

    Wajima, Zen'ichiro; Shiga, Toshiya; Yoshikawa, Tatsusuke; Ogura, Akira; Imanaga, Kazuyuki; Inoue, Tetsuo; Ogawa, Ryo

    2003-07-01

    After induction of anesthesia, lung resistance increases. The authors hypothesized that prophylactic bronchodilator treatment with intravenous colforsin daropate, a water-soluble forskolin derivative, before tracheal intubation would result in decreased lung resistance and increased lung compliance after tracheal intubation when compared with placebo medication. Forty-six adult patients were randomized to placebo or colforsin daropate treatment. Patients in the control group received normal saline; patients in the colforsin group received 0.75 microg. kg-1 x min-1 colforsin daropate intravenously until the study ended. Thirty minutes after the study began, the authors administered 5 mg/kg thiamylal and 5 microg/kg fentanyl for induction of general anesthesia and 0.3 mg/kg vecuronium for muscle relaxation. A 15-mg. kg-1. h-1 continuous infusion of thiamylal followed anesthetic induction. Four, 8, 12, and 16 min after tracheal intubation, mean airway resistance (R(awm)), expiratory airway resistance (R(awe)), and dynamic lung compliance (C(dyn)) were measured. Patients in the colforsin group had significantly lower R(awm) and R(awe) and higher C(dyn) after intubation than those in the control group. Differences in R(awm), R(awe), and C(dyn) between the two groups persisted through the final measurement at 16 min. At 4 min after intubation, smokers had a higher R(awm) and a lower C(dyn) than nonsmokers in the control group. After treatment by intravenous colforsin daropate, R(awm), R(awe), and C(dyn) values were similar for smokers and nonsmokers after tracheal intubation. Prophylactic treatment with colforsin daropate produced lower R(awm) and R(awe) and higher C(dyn) after tracheal intubation when compared with placebo medication. Pretreatment before intubation may be beneficial and advantageous for middle-aged smokers.

  6. The effects of water lubrication of tracheal tubes on post-intubation airway complications: study protocol for a randomized controlled trial.

    PubMed

    Kim, Eugene; Yang, Seong Mi; Yoon, So Jeong; Bahk, Jae-Hyon; Seo, Jeong-Hwa

    2016-11-25

    Water is known to have lubricating properties, thus it is used for lubrication of tracheal tubes to reduce airway injuries caused by intubation. However, there is no definite evidence to substantiate the beneficial effects of lubricating tracheal tubes using water for attenuating airway injuries. Moreover, the lubrication pretreatment may cause contamination of the tube, leading to respiratory infections. Therefore, this trial aims to assess whether no pretreatment of tracheal tubes does not increase post-intubation airway complications as compared with water lubrication of tubes. This is a prospective, double-blind, single-center, parallel-arm, noninferiority, randomized controlled trial to be conducted in participants aged 20-80 years who are undergoing elective surgery under general anesthesia with orotracheal intubation. Participants are randomly assigned into one of two groups depending on whether intubation is performed using a tracheal tube lubricated with water (n = 150) or without any pretreatment (n = 150). The primary outcome is the incidence of sore throat at 0, 2, 4, and 24 h after surgery, which is analyzed with a noninferiority test. The secondary outcomes are the incidence and severity of postoperative hoarseness, oropharyngeal injuries, and respiratory infections. Because we hypothesized that lubricating tracheal tubes using water has no advantage in reducing airway injuries associated with intubation, we will compare the incidence of sore throat, which is the most common complaint after intubation, in a noninferiority manner. This is the first randomized controlled trial to investigate the possibly beneficial or harmful effects of lubricating tracheal tubes using water before intubation. We expect that this trial will provide useful evidence to formulate a protocol for preparing tracheal tubes before intubation. This trial is registered at ClinicalTrials.gov on 1 July 2015 ( NCT02492646 ).

  7. The Pentax airway scope versus the Macintosh laryngoscope: Comparison of hemodynamic responses and concentrations of plasma norepinephrine to tracheal intubation

    PubMed Central

    2013-01-01

    Background The Pentax Airway Scope (AWS) is a video laryngoscope designed to facilitate tracheal intubation with a high-resolution image. The Pentax AWS has been reported to cause less hemodynamic stress than the Macintosh laryngoscope. The aims of this study are to investigate the differences in hemodynamic responses and norepinephrine concentrations to tracheal intubation between procedures using he Pentax AWS and the Macintosh laryngoscope. Methods Forty patients (American Society of Anesthesiologists class I-II, age range: 18-60 years) were randomly assigned to be intubated with either the Pentax AWS or the Macintosh laryngoscope while under general anesthesia. Routine monitoring, including invasive arterial blood pressure and bispectral index, were applied. Thiopental (4 mg/kg), fentanyl (1 µg/kg), midazolam (0.05 mg/kg), and rocuronium (0.6 mg/kg) were administered for anesthetic induction. Systolic, diastolic, and mean blood pressures and heart rates were recorded pre-intubation, immediately post-intubation (T0), and over the following 10 minutes at one minute intervals (T1, T2, T3, T4, T5…T10). Patient blood was sampled for norepinephrine concentrations pre-intubation (baseline) and post-intubation (T1). Evidence of sore throat was evaluated 30 min and 24 hr after extubation. Data were transformed to % basal and expressed as mean ± SD. Results The systolic, diastolic, and mean blood pressure, and heart rate at T0 and T4 were significantly different between the two groups. There was no significant difference in plasma norepinephrine between the two groups. The difference in incidence of sore throat was not significant between the two groups. Conclusions Pentax-AWS for tracheal intubation has greater hemodynamic stability than the Macintosh blade laryngoscope. PMID:23646240

  8. Awake intubation creates feelings of being in a vulnerable situation but cared for in safe hands: a qualitative study.

    PubMed

    Knudsen, Kati; Nilsson, Ulrica; Högman, Marieann; Pöder, Ulrika

    2016-08-30

    Awake fiberoptic intubation is an alternative procedure for securing the airway and is a recommended option when a difficult airway is expected. The aim of the present study was to describe patient experiences with this procedure. A qualitative, descriptive design was used and patients were recruited from three county hospitals and one university hospital in Sweden. Data was collected by semi-structured interviews with 13 patients who underwent awake fiberoptic intubation. A qualitative content analysis extracted theme, categories, and subcategories. From the patient statements, one main theme emerged, feelings of being in a vulnerable situation but cared for in safe hands, which were described in five categories with 15 subcategories. The categories were: a need for tailored information, distress and fear of the intubation, acceptance and trust of the staff's competence, professional caring and support, and no hesitation about new awake intubation. The patients felt they lacked information about what to expect and relied on the professionals' expertise. Some patients felt overwhelmed by the information they were given and wanted less specific information about the equipment used but more information about how they would be cared for in the operating room. Undergoing awake intubation was an acceptable experience for most patients, whereas others experienced it as being painful and terrifying because they felt they could not breathe or communicate during the procedure itself. Tailored information about what to expect, ensuring eye contact and breathing instruction during the procedure seems to reduce patient distress when undergoing awake fiberoptic intubation. Most of the patients would not hesitate to undergo awake intubation again in the future if needed.

  9. Inlets, ducts, and nozzles

    NASA Technical Reports Server (NTRS)

    Abbott, John M.; Anderson, Bernhard H.; Rice, Edward J.

    1990-01-01

    The internal fluid mechanics research program in inlets, ducts, and nozzles consists of a balanced effort between the development of computational tools (both parabolized Navier-Stokes and full Navier-Stokes) and the conduct of experimental research. The experiments are designed to better understand the fluid flow physics, to develop new or improved flow models, and to provide benchmark quality data sets for validation of the computational methods. The inlet, duct, and nozzle research program is described according to three major classifications of flow phenomena: (1) highly 3-D flow fields; (2) shock-boundary-layer interactions; and (3) shear layer control. Specific examples of current and future elements of the research program are described for each of these phenomenon. In particular, the highly 3-D flow field phenomenon is highlighted by describing the computational and experimental research program in transition ducts having a round-to-rectangular area variation. In the case of shock-boundary-layer interactions, the specific details of research for normal shock-boundary-layer interactions are described. For shear layer control, research in vortex generators and the use of aerodynamic excitation for enhancement of the jet mixing process are described.

  10. Clinical dysphagia risk predictors after prolonged orotracheal intubation

    PubMed Central

    de Medeiros, Gisele Chagas; Sassi, Fernanda Chiarion; Mangilli, Laura Davison; Zilberstein, Bruno; de Andrade, Claudia Regina Furquim

    2014-01-01

    OBJECTIVES: To elucidate independent risk factors for dysphagia after prolonged orotracheal intubation. METHODS: The participants were 148 consecutive patients who underwent clinical bedside swallowing assessments from September 2009 to September 2011. All patients had received prolonged orotracheal intubations and were admitted to one of several intensive care units of a large Brazilian school hospital. The correlations between the conducted water swallow test results and dysphagia risk levels were analyzed for statistical significance. RESULTS: Of the 148 patients included in the study, 91 were male and 57 were female (mean age, 53.64 years). The univariate analysis results indicated that specific variables, including extraoral loss, multiple swallows, cervical auscultation, vocal quality, cough, choking, and other signs, were possible significant high-risk indicators of dysphagia onset. The multivariate analysis results indicated that cervical auscultation and coughing were independent predictive variables for high dysphagia risk. CONCLUSIONS: Patients displaying extraoral loss, multiple swallows, cervical auscultation, vocal quality, cough, choking and other signs should benefit from early swallowing evaluations. Additionally, early post-extubation dysfunction recognition is paramount in reducing the morbidity rate in this high-risk population. PMID:24473554

  11. Bile duct obstruction

    MedlinePlus

    ... Tumors that have spread to the biliary system Liver and bile duct worms (flukes) The risk factors include: History of ... Increased bilirubin level Increased alkaline phosphatase level Increased liver enzymes The ... CT scan Endoscopic retrograde cholangiopancreatography ( ...

  12. Pancreatic-duct-lavage cytology in candidates for surgical resection of branch-duct intraductal papillary mucinous neoplasm of the pancreas: should the International Consensus Guidelines be revised?

    PubMed

    Sai, Jin Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio; Maehara, Tadayuki

    2009-03-01

    The International Consensus Guidelines are helpful for the management of branch-duct intraductal papillary mucinous neoplasms (IPMNs), because they allow us to exclude malignancy. However, it is not possible to predict malignancy with certainty, and further preoperative differentiation between benign and malignant IPMNs is required to avoid the false-positive results. To examine the usefulness of pancreatic-duct-lavage cytology by using an originally designed double-lumen catheter for discriminating benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines. Pancreatic-duct-lavage cytology was investigated in 24 patients with branch-duct IPMNs who underwent surgical resection based on the International Consensus Guidelines, namely, they either had intramural nodules or the ectatic branch duct was >30 mm in diameter. Single-center retrospective study. Academic medical center. The sensitivity and specificity of pancreatic-duct-lavage cytology for discriminating benign from malignant IPMNs. More than 30 mL of pancreatic-duct-lavage fluid was obtained from each patient, and there were no patients with noninformative results. The sensitivity, specificity, positive predictive value, and negative predictive value of the cytologic diagnosis were 78%, 93%, 88%, and 88%, respectively. Single-center and small number of patients. Pancreatic-duct-lavage cytology can improve differentiation between benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines.

  13. [Syncrhonous carcinosarcoma of the extrahepatic bile duct and gallbladder.

    PubMed

    Páramo, Ana Alberca; Valverde, David Padilla; Campos, Pedro Villarejo; Santos, Esther Pilar Garcia; Puche, Jose Luis Bertelli; Guerrero, Paloma Núńez; Delgado, Margarita; Fernindez, Jesus Martin

    2016-03-01

    Carcinosarcoma is a malignant neoplasm characterized for intermingled epithelial and mesenchymal components. A preoperative suspected diagnosis will allow a radical therapy avoiding a very bad prognosis. We report on a male patient who was operated in our Service with diagnosis of synchronous carcinosarcoma of gallbladder and extrahepatic bile duct and a review of the Medical Literature. A gallblader carcinosarcoma showing extension into common bile duct is very rare, a carcinosarcoma of the bile duct is exceptional, and a synchronous carcinosarcoma ofthe bile duct and gallbladder has not been reported previously.

  14. Verification of endotracheal intubation in obese patients - temporal comparison of ultrasound vs. auscultation and capnography.

    PubMed

    Pfeiffer, P; Bache, S; Isbye, D L; Rudolph, S S; Rovsing, L; Børglum, J

    2012-05-01

    Ultrasound (US) may have an emerging role as an adjunct in verification of endotracheal intubation. Obtaining optimal US images in obese patients is generally regarded more difficult than for other patients. This study compared the time consumption of bilateral lung US with auscultation and capnography for verifying endotracheal intubation in obese patients. A prospective, paired and investigator-blinded study performed in the operating theatre. Twenty-four adult patients requiring endotracheal intubation for bariatric surgery were included. During post-intubation bag ventilation, bilateral lung US was performed for detection of lungsliding indicating lung ventilation simultaneous with capnography and auscultation of epigastrium and chest. Primary outcome measure was the time difference to confirmed endotracheal intubation between US and auscultation alone. The secondary outcome measure was time difference between US and auscultation combined with capnography. Both methods verified endotracheal tube placement in all patients. No significant difference was found between US compared with auscultation alone. Median time for verification by auscultation alone was 47.5 s [interquartile (IQR) 40-51 s], with a mean difference of -0.3 s in favor of US (95% confidence interval -3.5-2.9 s) P = 0.87. Comparing US with the combination of auscultation and capnography, there was a significant difference between the two methods. Median time for verification by US was 43 s (IQR 40-51 s) vs. 55 s (IQR 46-65 s), P < 0.0001. In obese patients, verification of endotracheal tube placement with US is as fast as auscultation alone and faster than the standard method of auscultation and capnography. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

  15. Anomalous pancreatico-biliary ductal union with cystic dilatation of the bile duct.

    PubMed

    Richer, J P; Faure, J P; Morichau-Beauchant, M; Dugue, T; Maillot, N; Kamina, P; Carretier, M

    1998-01-01

    We report, in an adult, an asymptomatic association between cystic dilation of the bile duct (type IV A in Todani's classification) and anomalous pancreatico-biliary ductal union (APBD) with stones in a long common channel. In APBD, the connection between the common bile duct and the main pancreatic duct is located outside the duodenal wall andis therefore not under the influence of the sphincter of Boyden. An abnormally long common channel is in excess of 15 mm. Two types of convergence anomalies are defined according to whether the bile duct opens into the main pancreatic duct (BP) or the main pancreatic duct into the bile duct (PB). In APBD, there is probably a reverse pressure gradient between the bile and pancreatic ducts, with regurgitation of pancreatic juice into the bile duct, repeated attacks of cholangitis, stenosis and cystic dilatation. A long common channel is associated with a higher incidence of carcinoma of the gall bladder of the bile duct.

  16. Fluid flow in a spiral microfluidic duct

    NASA Astrophysics Data System (ADS)

    Harding, Brendan; Stokes, Yvonne

    2018-04-01

    We consider the steady, pressure driven flow of a viscous fluid through a microfluidic device having the geometry of a planar spiral duct with a slowly varying curvature and height smaller than width. For this problem, it is convenient to express the Navier-Stokes equations in terms of a non-orthogonal coordinate system. Then, after applying appropriate scalings, the leading order equations admit a relatively simple solution in the central region of the duct cross section. First-order corrections with respect to the duct curvature and aspect ratio parameters are also obtained for this region. Additional correction terms are needed to ensure that no slip and no penetration conditions are satisfied on the side walls. Our solutions allow for a top wall shape that varies with respect to the radial coordinate which allows us to study the flow in a variety of cross-sectional shapes, including trapezoidal-shaped ducts that have been studied experimentally. At leading order, the flow is found to depend on the local height and slope of the top wall within the central region. The solutions are compared with numerical approximations of a classical Dean flow and are found to be in good agreement for a small duct aspect ratio and a slowly varying and small curvature. We conclude that the slowly varying curvature typical of spiral microfluidic devices has a negligible impact on the flow in the sense that locally the flow does not differ significantly from the classical Dean flow through a duct having the same curvature.

  17. Intraductal papillary neoplasm originating from an anomalous bile duct.

    PubMed

    Maki, Harufumi; Aoki, Taku; Ishizawa, Takeaki; Tanaka, Mariko; Sakatani, Takashi; Beck, Yoshifumi; Hasegawa, Kiyoshi; Sakamoto, Yoshihiro; Kokudo, Norihiro

    2017-04-01

    An 82-year-old woman who had been suffering from repeated obstructive jaundice for 7 years was referred to our hospital. Although endoscopic aspiration of the mucin in the common bile duct had been temporally effective, origin of the mucin production had not been detectable. The patient thus had been forced to be on long-term follow-up without curative resection. Endoscopic retrograde cholangioscopy on admission revealed massive mucin in the common bile duct. In addition, an anomalous bile duct located proximal to the gallbladder was identified. Since the lumen of the anomalous duct was irregular and the rest of biliary tree was completely free of suspicious lesions, the anomalous duct was judged to be the primary site. Surgical resection of the segment 4 and 5 of the liver combined with the extrahepatic biliary tract was performed. Pathological diagnosis was compatible to intraductal papillary neoplasm with high-grade intraepithelial dysplasia of the anomalous bile duct. The patient has been free from the disease for 6.5 years after resection. This is the first case of intraductal papillary neoplasm derived from an anomalous bile duct, which was resected after long-term conservative treatment. The present case suggested the slow growing character of natural history of the neoplasm.

  18. Generation of Higher Order Modes in a Rectangular Duct

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Cabell, Randolph H.; Brown, Donald E.

    2004-01-01

    Advanced noise control methodologies to reduce sound emission from aircraft engines take advantage of the modal structure of the noise in the duct. This noise is caused by the interaction of rotor wakes with downstream obstructions such as exit guide vanes. Mode synthesis has been accomplished in circular ducts and current active noise control work has made use of this capability to cancel fan noise. The goal of the current effort is to examine the fundamental process of higher order mode propagation through an acoustically treated, curved duct. The duct cross-section is rectangular to permit greater flexibility in representation of a range of duct curvatures. The work presented is the development of a feedforward control system to generate a user-specified modal pattern in the duct. The multiple-error, filtered-x LMS algorithm is used to determine the magnitude and phase of signal input to the loudspeakers to produce a desired modal pattern at a set of error microphones. Implementation issues, including loudspeaker placement and error microphone placement, are discussed. Preliminary results from a 9-3/8 inch by 21 inch duct, using 12 loudspeakers and 24 microphones, are presented. These results demonstrate the ability of the control system to generate a user-specified mode while suppressing undesired modes.

  19. A brief history of tracheostomy and tracheal intubation, from the Bronze Age to the Space Age.

    PubMed

    Szmuk, Peter; Ezri, Tiberiu; Evron, Shmuel; Roth, Yehudah; Katz, Jeffrey

    2008-02-01

    To present a concise history of tracheostomy and tracheal intubation for the approximately forty centuries from their earliest description around 2000 BC until the middle of the twentieth century, at which time a proliferation of advances marked the beginning of the modern era of anesthesiology. Review of the literature. The colorful and checkered past of tracheostomy and tracheal intubation informs contemporary understanding of these procedures. Often, the decision whether to perform a life-saving tracheostomy or tracheal intubation has been as important as the technical ability to perform it. The dawn of modern airway management owes its existence to the historical development of increasingly effective airway devices and to regular contributions of research into the pathophysiology of the upper airway.

  20. Betel quid, chewing habits and difficult intubation: A case report and critical appraisal of evidence for practice.

    PubMed

    Narendra, P L; Hegde, Harihar V; Vijaykumar, T K; Nallamilli, Samson

    2015-01-01

    Betel quid is used by 10-20% of world of population. Oral submucus fibrosis (OSF) is a chronic premalignant disease common in South Asian countries where betel quid is chewed. It is characterized by juxtaepithelial fibrosis of oral cavity and limited mouth opening, which can cause difficult intubation. A recent study in Taiwan has revealed long-term betel nut chewing is not predictor of difficult intubation. We describe two cases of OSF and critically analyze this study and its implications for clinical practice. OSF is now seen in Saudi Arabia and western countries with use of commercial betel quid substitutes. Although betel quid without tobacco is used in Taiwan, available evidence suggests rapid and early development of OSF where commercial chewing products like Pan Masala are used in India. Effects of betel quid may vary depending on the composition of quid and chewing habits. Studies where personal habits are involved must be analyzed carefully for external validity. Even though, Taiwan study is controlled, its validity outside Taiwan is highly questionable. Since OSF can cause unanticipated difficult intubation, thus during preanesthetic assessment, history of betel quid chewing, more importantly use of commercial chewing products is more likely to give clues to severity of OSF and possible difficult intubation. Further controlled trails in populations where commercial chewing products are used is necessary to detect association of chewing habits and difficult intubation.

  1. Preventing pressure sores of the nasal ala after nasotracheal tube intubation: from animal model to clinical application.

    PubMed

    Huang, Tze-Ta; Tseng, Chih-En; Lee, Tsan-Mu; Yeh, Jen-Ying; Lai, Yu-Yung

    2009-03-01

    Nasal-ala pressure sores induced by nasotracheal intubation are common complications of oral and maxillofacial surgery, but are easily ignored. To determine whether such sores could be prevented, we studied the effects of a combination of cushioning material in an animal model, and then analyzed the efficacy of this combination clinically. Four pigs received nasotracheal intubation. Each pig received intubation for 4, 8, 12, or 16 hours. Outcomes from pigs undergoing 500-gram-weight compression on each nostril were compared: one nostril received an application of cushioning materials, and the contralateral nostril did not. After the required study period, clinical assessment and further evaluation were performed by measuring pressure-sore dimensions and performing incisional biopsies. Clinical applications of this protective technique were then undertaken. Eight patients who underwent intubation without Soft Liner (GC Co, Tokyo, Japan) and DuoDERM CGF (ConvaTec, Inc, Princeton, NJ) protection, and 10 patients with Soft Liner and DuoDERM protection, were evaluated. The protective efficacy of the cushioning materials was significant in the animal model as well as in clinical practice. Pressure sores were avoided on the protected side, with severe tissue necrosis documented on the control side. We found that the combined use of Soft Liner and DuoDERM reduced the size and severity of nasal-ala pressure sores attributable to nasotracheal intubation during oral and maxillofacial surgery.

  2. Comparison of the TruView infant EVO2 PCD™ and C-MAC video laryngoscopes with direct Macintosh laryngoscopy for routine tracheal intubation in infants with normal airways

    PubMed Central

    Mutlak, Haitham; Rolle, Udo; Rosskopf, Willi; Schalk, Richard; Zacharowski, Kai; Meininger, Dirk; Byhahn, Christian

    2014-01-01

    OBJECTIVE: Videolaryngoscopy has mainly been developed to facilitate difficult airway intubation. However, there is a lack of studies demonstrating this method's efficacy in pediatric patients. The aim of the present study was to compare the TruView infant EVO2 and the C-MAC videolaryngoscope with conventional direct Macintosh laryngoscopy in children with a bodyweight ≤10 kg in terms of intubation conditions and the time to intubation. METHODS: In total, 65 children with a bodyweight ≤10 kg (0-22 months) who had undergone elective surgery requiring endotracheal intubation were retrospectively analyzed. Our database was screened for intubations with the TruView infant EVO2, the C-MAC videolaryngoscope, and conventional direct Macintosh laryngoscopy. The intubation conditions, the time to intubation, and the oxygen saturation before and after intubation were monitored, and demographic data were recorded. Only children with a bodyweight ≤10 kg were included in the analysis. RESULTS: A total of 23 children were intubated using the C-MAC videolaryngoscope, and 22 children were intubated using the TruView EVO2. Additionally, 20 children were intubated using a standard Macintosh blade. The time required for tracheal intubation was significantly longer using the TruView EVO2 (52 sec vs. 28 sec for C-MAC vs. 26 sec for direct LG). However, no significant difference in oxygen saturation was found after intubation. CONCLUSION: All devices allowed excellent visualization of the vocal cords, but the time to intubation was prolonged when the TruView EVO2 was used. The absence of a decline in oxygen saturation may be due to apneic oxygenation via the TruView scope and may provide a margin of safety. In sum, the use of the TruView by a well-trained anesthetist may be an alternative for difficult airway management in pediatric patients. PMID:24473556

  3. Investigation of the tone-burst tube for duct lining attenuation measurement

    NASA Technical Reports Server (NTRS)

    Soffel, A. R.; Morrow, P. F.

    1972-01-01

    The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

  4. Post-Tensioning Duct Air Pressure Testing Effects on Web Cracking

    DOT National Transportation Integrated Search

    2015-01-01

    Nevada Department of Transportation (NDOT) post-tensioned concrete bridges have experienced web cracking near the post-tensioning ducts during the construction process. The ducts were air pressure tested to ensure the duct can successfully be grouted...

  5. Energy efficient engine: Turbine transition duct model technology report

    NASA Technical Reports Server (NTRS)

    Leach, K.; Thurlin, R.

    1982-01-01

    The Low-Pressure Turbine Transition Duct Model Technology Program was directed toward substantiating the aerodynamic definition of a turbine transition duct for the Energy Efficient Engine. This effort was successful in demonstrating an aerodynamically viable compact duct geometry and the performance benefits associated with a low camber low-pressure turbine inlet guide vane. The transition duct design for the flight propulsion system was tested and the pressure loss goal of 0.7 percent was verified. Also, strut fairing pressure distributions, as well as wall pressure coefficients, were in close agreement with analytical predictions. Duct modifications for the integrated core/low spool were also evaluated. The total pressure loss was 1.59 percent. Although the increase in exit area in this design produced higher wall loadings, reflecting a more aggressive aerodynamic design, pressure profiles showed no evidence of flow separation. Overall, the results acquired have provided pertinent design and diagnostic information for the design of a turbine transition duct for both the flight propulsion system and the integrated core/low spool.

  6. Liver and Bile Duct Cancer—Patient Version

    Cancer.gov

    Liver cancer includes hepatocellular carcinoma and bile duct cancer (cholangiocarcinoma). Risk factors for HCC include chronic infection with hepatitis B or C and cirrhosis of the liver. Start here to find information on liver and bile duct cancer treatment, causes and prevention, screening, research, and statistics.

  7. Bile duct anastomotic stricture after pediatric living donor liver transplantation.

    PubMed

    Chok, Kenneth S H; Chan, See Ching; Chan, Kwong Leung; Sharr, William W; Tam, Paul K H; Fan, Sheung Tat; Lo, Chung Mau

    2012-07-01

    Hepaticojejunostomy is a well-accepted method, whereas duct-to-duct anastomosis is gaining popularity for bile duct reconstruction in pediatric living donor liver transplantation (LDLT). Biliary complications, especially biliary anastomotic stricture (BAS), are not clearly defined. The aim of the present study is to determine the rate of BAS and its associated risk factors. The study included 78 pediatric patients (<18 years old) who underwent LDLT during the period from end of September 1993 to end of November 2010. The diagnosis of BAS was based on clinical, biochemical, histologic, and radiologic results. All patients received left-side grafts. Thirteen patients (16.7%) developed BAS after LDLT. Among them, 3 patients (23.1%) had duct-to-duct anastomosis during LDLT. The median follow-up period for the BAS group and the non-BAS group was 57.8 and 79.5 months, respectively (P = .683). Ten of the patients with BAS required percutaneous transhepatic biliary drainage with or without dilatation for treating the stricture. Multivariable analysis showed that hepatic artery thrombosis and duct-to-duct anastomosis were 2 risk factors associated with BAS. In pediatric LDLT, hepaticojejunostomy is the preferred method for bile duct reconstruction, but more large-scale research needs to be done to reconfirm this result. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. A New Approach to Pathogen Containment in the Operating Room: Sheathing the Laryngoscope After Intubation.

    PubMed

    Birnbach, David J; Rosen, Lisa F; Fitzpatrick, Maureen; Carling, Philip; Arheart, Kristopher L; Munoz-Price, L Silvia

    2015-11-01

    Anesthesiologists may contribute to postoperative infections by means of the transmission of blood and pathogens to the patient and the environment in the operating room (OR). Our primary aims were to determine whether contamination of the IV hub, the anesthesia work area, and the patient could be reduced after induction of anesthesia by removing the risk associated with contaminants on the laryngoscope handle and blade. Therefore, we conducted a study in a simulated OR where some of the participants sheathed the laryngoscope handle and blade in a glove immediately after it was used to perform an endotracheal intubation. Forty-five anesthesiology residents (postgraduate year 2-4) were enrolled in a study consisting of identical simulation sessions. On entry to the simulated OR, the residents were asked to perform an anesthetic, including induction and endotracheal intubation timed to approximately 6 minutes. Of the 45 simulation sessions, 15 were with a control group conducted with the intubating resident wearing single gloves, 15 with the intubating resident using double gloves with the outer pair removed and discarded after verified intubation, and 15 wearing double gloves and sheathing the laryngoscope in one of the outer gloves after intubation. Before the start of the scenario, the lips and inside of the mouth of the mannequin were coated with a fluorescent marking gel. After each of the 45 simulations, an observer examined the OR using an ultraviolet light to determine the presence of fluorescence on 25 sites: 7 on the patient and 18 in the anesthesia environment. Of the 7 sites on the patient, ultraviolet light detected contamination on an average of 5.7 (95% confidence interval, 4.4-7.2) sites under the single-glove condition, 2.1 (1.5-3.1) sites with double gloves, and 0.4 (0.2-1.0) sites with double gloves with sheathing. All 3 conditions were significantly different from one another at P < 0.001. Of the 18 environmental sites, ultraviolet light detected

  9. Acoustic imaging of a duct spinning mode by the use of an in-duct circular microphone array.

    PubMed

    Wei, Qingkai; Huang, Xun; Peers, Edward

    2013-06-01

    An imaging method of acoustic spinning modes propagating within a circular duct simply with surface pressure information is introduced in this paper. The proposed method is developed in a theoretical way and is demonstrated by a numerical simulation case. Nowadays, the measurements within a duct have to be conducted using in-duct microphone array, which is unable to provide information of complete acoustic solutions across the test section. The proposed method can estimate immeasurable information by forming a so-called observer. The fundamental idea behind the testing method was originally developed in control theory for ordinary differential equations. Spinning mode propagation, however, is formulated in partial differential equations. A finite difference technique is used to reduce the associated partial differential equations to a classical form in control. The observer method can thereafter be applied straightforwardly. The algorithm is recursive and, thus, could be operated in real-time. A numerical simulation for a straight circular duct is conducted. The acoustic solutions on the test section can be reconstructed with good agreement to analytical solutions. The results suggest the potential and applications of the proposed method.

  10. Choledochoscopic Holmium Laser Lithotripsy for Difficult Bile Duct Stones.

    PubMed

    Lv, Shangdong; Fang, Zheping; Wang, Aidong; Yang, Jian; Zhang, Wenlong

    2017-01-01

    The aim of this study was to evaluate the feasibility and efficacy of choledochoscopic holmium laser lithotripsy as a means of removing resistant extrahepatic and intrahepatic bile duct stones. Clinical data on 28 patients who had undergone choledochoscopic holmium laser lithotripsy were analyzed. Complete stone clearance was obtained in 24 patients; small numbers of residual stones in the left or right hepatic duct were found in 4 patients. No severe complications such as hemobilia and bile duct injuries occurred. Choledochoscopic holmium laser lithotripsy is a simple, safe, and effective treatment method for patients with resistant bile duct stones.

  11. Flexible metallic seal for transition duct in turbine system

    DOEpatents

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2014-04-22

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a flexible metallic seal contacting the interface member to provide a seal between the interface member and the turbine section.

  12. Choleperitoneum due to intrahepatic bile duct rupture - case report.

    PubMed

    Simion, L; Straja, Dn; Prunoiu, Vm; Alecu, M; Brătucu, E

    2014-01-01

    Non-traumatic perforations of the bile ducts are unfrequently encountered entities, all the more when they affect the intrahepatic bile ducts, exteriorizing their biliary content in the great peritoneal cavity. Reporting such a case has determined the authors to perform a careful overview of the cases present in the literature. An observation that can be made based on these is that the obstruction of the main bile duct due to lithiasis determines, by pressure increase, the dilation of the bile system branches, all on the background of an unknown malformation of the intrahepatic bile ducts. Celsius.

  13. Obstetric Anaesthetists' Association and Difficult Airway Society guidelines for the management of difficult and failed tracheal intubation in obstetrics*

    PubMed Central

    Mushambi, M C; Kinsella, S M; Popat, M; Swales, H; Ramaswamy, K K; Winton, A L; Quinn, A C

    2015-01-01

    The Obstetric Anaesthetists' Association and Difficult Airway Society have developed the first national obstetric guidelines for the safe management of difficult and failed tracheal intubation during general anaesthesia. They comprise four algorithms and two tables. A master algorithm provides an overview. Algorithm 1 gives a framework on how to optimise a safe general anaesthetic technique in the obstetric patient, and emphasises: planning and multidisciplinary communication; how to prevent the rapid oxygen desaturation seen in pregnant women by advocating nasal oxygenation and mask ventilation immediately after induction; limiting intubation attempts to two; and consideration of early release of cricoid pressure if difficulties are encountered. Algorithm 2 summarises the management after declaring failed tracheal intubation with clear decision points, and encourages early insertion of a (preferably second-generation) supraglottic airway device if appropriate. Algorithm 3 covers the management of the ‘can't intubate, can't oxygenate’ situation and emergency front-of-neck airway access, including the necessity for timely perimortem caesarean section if maternal oxygenation cannot be achieved. Table 1 gives a structure for assessing the individual factors relevant in the decision to awaken or proceed should intubation fail, which include: urgency related to maternal or fetal factors; seniority of the anaesthetist; obesity of the patient; surgical complexity; aspiration risk; potential difficulty with provision of alternative anaesthesia; and post-induction airway device and airway patency. This decision should be considered by the team in advance of performing a general anaesthetic to make a provisional plan should failed intubation occur. The table is also intended to be used as a teaching tool to facilitate discussion and learning regarding the complex nature of decision-making when faced with a failed intubation. Table 2 gives practical considerations of how

  14. Technical realization of a sensorized neonatal intubation skill trainer for operators' retraining and a pilot study for its validation.

    PubMed

    Panizza, Davide; Scaramuzzo, Rosa T; Moscuzza, Francesca; Vannozzi, Ilaria; Ciantelli, Massimiliano; Gentile, Marzia; Baldoli, Ilaria; Tognarelli, Selene; Boldrini, Antonio; Cuttano, Armando

    2018-01-04

    In neonatal endotracheal intubation, excessive pressure on soft tissues during laryngoscopy can determine permanent injury. Low-fidelity skill trainers do not give valid feedback about this issue. This study describes the technical realization and validation of an active neonatal intubation skill trainer providing objective feedback. We studied expert health professionals' performances in neonatal intubation, underlining chance for procedure retraining. We identified the most critical points in epiglottis and dental arches and fixed commercial force sensors on chosen points on a ©Laerdal Neonatal Intubation Trainer. Our skill trainer was set up as a grade 3 on Cormack and Lehane's scale, i.e. a model of difficult intubation. An associated software provided real time sound feedback if pressure during laryngoscopy exceeded an established threshold. Pressure data were recorded in a database, for subsequent analysis with non-parametric statistical tests. We organized our study in two intubation sessions (5 attempts each one) for everyone of our participants, held 24 h apart. Between the two sessions, a debriefing phase took place. In addition, we gave our participants two interview, one at the beginning and one at the end of the study, to get information about our subjects and to have feedback about our design. We obtained statistical significant differences between consecutive attempts, with evidence of learning trends. Pressure on critical points was significantly lower during the second session (p < 0.0001). Epiglottis' sensor was the most stressed (p < 0.000001). We found a significant correlation between time spent for each attempt and pressures applied to the airways in the two sessions, more significant in the second one (shorter attempts with less pressure, r s  = 0.603). Our skill trainer represents a reliable model of difficult intubation. Our results show its potential to optimize procedures related to the control of trauma risk and to improve

  15. Observations of Strong Surface Radar Ducts over the Persian Gulf.

    NASA Astrophysics Data System (ADS)

    Brooks, Ian M.; Goroch, Andreas K.; Rogers, David P.

    1999-09-01

    Ducting of microwave radiation is a common phenomenon over the oceans. The height and strength of the duct are controlling factors for radar propagation and must be determined accurately to assess propagation ranges. A surface evaporation duct commonly forms due to the large gradient in specific humidity just above the sea surface; a deeper surface-based or elevated duct frequently is associated with the sudden change in temperature and humidity across the boundary layer inversion.In April 1996 the U.K. Meteorological Office C-130 Hercules research aircraft took part in the U.S. Navy Ship Antisubmarine Warfare Readiness/Effectiveness Measuring exercise (SHAREM-115) in the Persian Gulf by providing meteorological support and making measurements for the study of electromagnetic and electro-optical propagation. The boundary layer structure over the Gulf is influenced strongly by the surrounding desert landmass. Warm dry air flows from the desert over the cooler waters of the Gulf. Heat loss to the surface results in the formation of a stable internal boundary layer. The layer evolves continuously along wind, eventually forming a new marine atmospheric boundary layer. The stable stratification suppresses vertical mixing, trapping moisture within the layer and leading to an increase in refractive index and the formation of a strong boundary layer duct. A surface evaporation duct coexists with the boundary layer duct.In this paper the authors present aircraft- and ship-based observations of both the surface evaporation and boundary layer ducts. A series of sawtooth aircraft profiles map the boundary layer structure and provide spatially distributed estimates of the duct depth. The boundary layer duct is found to have considerable spatial variability in both depth and strength, and to evolve along wind over distances significant to naval operations (100 km). The depth of the evaporation duct is derived from a bulk parameterization based on Monin-Obukhov similarity theory

  16. Bile Duct Cancer (Cholangiocarcinoma)

    MedlinePlus

    ... and pediatric oncologists, oncology nurses, physician assistants, social workers, and patient advocates. Cancer.Net Guide Bile Duct Cancer (Cholangiocarcinoma) ... Team Additional Resources View All Pages f ...

  17. A comparison of a traditional endotracheal tube versus ETView SL in endotracheal intubation during different emergency conditions

    PubMed Central

    Truszewski, Zenon; Krajewski, Paweł; Fudalej, Marcin; Smereka, Jacek; Frass, Michael; Robak, Oliver; Nguyen, Bianka; Ruetzler, Kurt; Szarpak, Lukasz

    2016-01-01

    Abstract Background: Airway management is a crucial skill essential to paramedics and personnel working in Emergency Medical Services and Emergency Departments: Lack of practice, a difficult airway, or a trauma situation may limit the ability of paramedics to perform direct laryngoscopy during cardiopulmonary resuscitation. Videoscope devices are alternatives for airway management in these situations. The ETView VivaSight SL (ETView; ETView Ltd., Misgav, Israel) is a new, single-lumen airway tube with an integrated high-resolution imaging camera. To assess if the ETView VivaSight SL can be a superior alternative to a standard endotracheal tube for intubation in an adult cadaver model, both during and without simulated CPR. Methods: ETView VivaSight SL tube was investigated via an interventional, randomized, crossover, cadaver study. A total of 52 paramedics participated in the intubation of human cadavers in three different scenarios: a normal airway at rest without concomitant chest compression (CC) (scenario A), a normal airway with uninterrupted CC (scenario B) and manual in-line stabilization (scenario C). Time and rate of success for intubation, the glottic view scale, and ease-of-use of ETView vs. sETT intubation were assessed for each emergency scenario. Results: The median time to intubation using ETView vs. sETT was compared for each of the aforementioned scenarios. For scenario A, time to first ventilation was achieved fastest for ETView, 19.5 [IQR, 16.5–22] sec, when compared to that of sETT at 21.5 [IQR, 20–25] sec (p = .013). In scenario B, the time for intubation using ETView was 21 [IQR, 18.5–24.5] sec (p < .001) and sETT was 27 [IQR, 24.5–31.5] sec. Time to first ventilation for scenario C was 23.5 [IQR, 19–25.5] sec for the ETView and 42.5 [IQR, 35–49.5] sec for sETT. Conclusions: In normal airways and situations with continuous chest compressions, the success rate for intubation of cadavers and the time to ventilation were

  18. Effect of gabapentin pretreatment on the hemodynamic response to laryngoscopy and tracheal intubation in treated hypertensive patients.

    PubMed

    Bala, Indu; Bharti, Neerja; Ramesh, Nanjangud P

    2015-09-01

    This randomized, double-blind study was conducted to evaluate the effect of gabapentin pretreatment on the hemodynamic response to laryngoscopy and endotracheal intubation (LETI) in treated hypertensive patients undergoing surgery. A total of 100 controlled hypertensive patients aged 35-60 years, undergoing elective surgery under general anesthesia with endotracheal intubation, were randomly allocated into three groups. Group 1 patients received placebo at night and 2 hours prior to induction of anesthesia. Group 2 patients received placebo at night and 800 mg gabapentin 2 hours prior to induction of anesthesia. Group 3 patients received 800 mg gabapentin at night and 2 hours prior to induction of anesthesia. Anesthesia was induced with thiopentone, fentanyl, and vecuronium and maintained with isoflurane in oxygen and nitrous oxide. Patients' heart rate (HR), blood pressure (BP), and electrocardiography (ECG) changes were recorded prior to induction, after induction, and at 0 minutes, 1 minute, 3 minutes, 5 minutes, and 10 minutes after intubation. Any episodes of hypotension, bradycardia, tachycardia, hypertension, arrhythmia, and ST-T wave changes were recorded and treated accordingly. The HR was comparable among groups, with a transient rise just after intubation, followed by a gradual fall thereafter at 3 minutes, 5 minutes, and 10 minutes compared with baseline. A significant increase in BP after intubation was reported in Group 1 but not in Group 2 and Group 3. The mean arterial pressure (MAP) was significantly higher in Group 1 at 0 minute, 1 minute and 3 minutes postintubation as compared with Group 2 and Group 3 (p=0.014). Three patients in Group 1, four patients in Group 2, and 10 patients in Group 3 developed hypotension and were treated with ephedrine, whereas five patients in Group 1 and one patient in Group 2 had hypertension after tracheal intubation. There was no significant difference between the groups with respect to the number of patients who

  19. Results and comparison of Hall and DW duct experiments

    NASA Technical Reports Server (NTRS)

    Smith, J. M.; Morgan, J. L.

    1982-01-01

    Experimental data from recent tests of a 45 deg diagonal wall duct are presented and compared with the results of a similar Hall duct. It is shown that while the peak power density of the two devices is approximately equal that the diagonal wall duct produces greater total power output due to its ability to better utilize the available magnetic field.

  20. Thrust control system design of ducted rockets

    NASA Astrophysics Data System (ADS)

    Chang, Juntao; Li, Bin; Bao, Wen; Niu, Wenyu; Yu, Daren

    2011-07-01

    The investigation of the thrust control system is aroused by the need for propulsion system of ducted rockets. Firstly the dynamic mathematical models of gas flow regulating system, pneumatic servo system and ducted rocket engine were established and analyzed. Then, to conquer the discussed problems of thrust control, the idea of information fusion was proposed to construct a new feedback variable. With this fused feedback variable, the thrust control system was designed. According to the simulation results, the introduction of the new fused feedback variable is valid in eliminating the contradiction between rapid response and stability for the thrust control system of ducted rockets.

  1. Ducting arrangement for cooling a gas turbine structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ching-Pang; Morrison, Jay A.

    2015-07-21

    A ducting arrangement (10) for a can annular gas turbine engine, including: a duct (12, 14) disposed between a combustor (16) and a first row of turbine blades and defining a hot gas path (30) therein, the duct (12, 14) having raised geometric features (54) incorporated into an outer surface (80); and a flow sleeve (72) defining a cooling flow path (84) between an inner surface (78) of the flow sleeve (72) and the duct outer surface (80). After a cooling fluid (86) traverses a relatively upstream raised geometric feature (90), the inner surface (78) of the flow sleeve (72)more » is effective to direct the cooling fluid (86) toward a landing (94) separating the relatively upstream raised geometric feature (90) from a relatively downstream raised geometric feature (94).« less

  2. A simple method for accurate endotracheal placement of an intubation tube in Guinea pigs to assess lung injury following chemical exposure.

    PubMed

    Nambiar, M P; Gordon, R K; Moran, T S; Richards, S M; Sciuto, A M

    2007-01-01

    ABSTRACT Guinea pigs are considered as the animal model of choice for toxicology and medical countermeasure studies against chemical warfare agents (CWAs) and toxic organophosphate pesticides because of the low levels of carboxylesterase compared to rats and mice. However, it is difficult to intubate guinea pigs without damaging the larynx to perform CWA inhalation experiments. We describe an easy technique of intubation of guinea pigs for accurate endotracheal placement of the intubation tube. The technique involves a speculum made by cutting the medium-size ear speculum in the midline leaving behind the intact circular connector to the otoscope. Guinea pigs were anesthetized with Telazol/meditomidine, the tongue was pulled using blunt forceps, and an otoscope attached with the specially prepared speculum was inserted gently. Insertion of the speculum raises the epiglottis and restrains the movements of vocal cord, which allows smooth insertion of the metal stylet-reinforced intubation tube. Accurate endotracheal placement of the intubation tube was achieved by measuring the length from the tracheal bifurcation to vocal cord and vocal cord to the upper front teeth. The average length of the trachea in guinea pigs (275 +/- 25 g) was 5.5 +/- 0.2 cm and the distance from the vocal cord to the front teeth was typically 3 cm. Coinciding an intubation tube marked at 6 cm with the upper front teeth accurately places the intubation tube 2.5 cm above the tracheal bifurcation. This simple method of intubation does not disturb the natural flora of the mouth and causes minimum laryngeal damage. It is rapid and reliable, and will be very valuable in inhalation exposure to chemical/biological warfare agents or toxic chemicals to assess respiratory toxicity and develop medical countermeasures.

  3. Propagation Of Sound In Curved Ducts

    NASA Technical Reports Server (NTRS)

    Rostafinski, Wojciech

    1992-01-01

    Monograph presents concise, comprehensive summary of knowledge of propagation of acoustic waves in ducts and pipes including bends. Pulls together information from Lord Rayleigh's book Theory Of Sound, published in 1878, and from 33 papers scattered throughout various scientific journals published between 1945 and 1989. Monograph useful to scientists and engineers interested in such diverse topics as musical instruments, air-conditioning ducts, and jet engines. Material not available in current texts.

  4. Human factors in the emergency department: Is physician perception of time to intubation and desaturation rate accurate?

    PubMed

    Cemalovic, Nail; Scoccimarro, Anthony; Arslan, Albert; Fraser, Robert; Kanter, Marc; Caputo, Nicholas

    2016-06-01

    The main objective of the present study was to examine the perceived versus actual time to intubation (TTI) as an indication to help determine the situational awareness of Emergency Physicians during rapid sequence intubation and, additionally, to determine the physician's perception of desaturation events. A timed, observation prospective cohort study was conducted. A post-intubation survey was administered to the intubating physician. Each step of the procedure was timed by an observer in order to determine actual TTI. The number of desaturation events was also recorded. One hundred individual intubations were included. The provider perceived TTI was significantly different and underestimated when compared with the actual TTI (23 s, 95% confidence interval (CI) 20.4-25.49 vs 45.5 s, 95% CI 40.2-50.7, P < 0.001, respectively). Pearson correlation coefficient of perceived TTI to actual TTI was r(2)  = 0.39 (95% CI 0.21-0.54, P < 0.001). The provider perceived desaturation rate was also significantly different from actual desaturation rate (13, 95% CI 3-12 vs 23, 95% CI 13-29, P = 0.05, respectively). The overall time to desaturation was 65.1 s. Our findings have shown that provider's perception of TTI occurs sooner than actually observed. Also, the providers were less aware of desaturation during the procedure. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  5. Endoscopic stenting in bile duct cancer increases liver volume.

    PubMed

    Lee, Chang Hun; Kim, Seong Hun; Kim, In Hee; Kim, Sang Wook; Lee, Soo Teik; Kim, Dae Ghon; Yang, Jae Do; Yu, Hee Chul; Cho, Baik Hwan; Lee, Seung Ok

    2014-09-01

    Objective evaluation tools for assessing the effectiveness of stenting in palliative treatment of malignant biliary obstruction are not satisfactory. Effects of biliary stenting on liver volume change have never been studied. We aimed to use volumetry to analyze liver volume changes after endoscopic stenting in bile duct cancer according to the location and number of stents. Retrospective review. University hospital. Patients with a diagnosis of hilar or distal bile duct cancer and who underwent biliary metal stenting. ERCP with self-expandable metal stent placement. Liver volume change after biliary stenting and its comparison according to the location (hilar vs distal common bile duct) and number (hilar bilateral vs hilar unilateral). There were 60 patients; 31 were treated for hilar bile duct cancer (13 for bilateral stent and 18 for unilateral stent) and 29 for distal bile duct cancer. Overall mean follow-up duration was 11.7 ± 4.9 weeks. Liver volume increased 17.4 ± 24.1%. The rate of liver growth was rapid during the early period from 4 to 8 weeks. Stenting in hilar bile duct cancer tended to increase liver volume more than distal biliary stents (22.5% vs 11.9%, P = .091). In hilar bile duct cancer, unilateral and bilateral stents showed similar liver volume increases (20.1% and 25.8%, respectively; P = .512). Single center, retrospective. Biliary stenting markedly increased liver volume in both hilar and distal bile duct cancer. Our data suggest that liver volume assessment could be a useful tool for evaluating stent efficacy. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  6. Reconstruction of Bile Duct Injury and Defect with the Round Ligament.

    PubMed

    Dokmak, Safi; Aussilhou, Béatrice; Ragot, Emilia; Tantardini, Camille; Cauchy, François; Ponsot, Philippe; Belghiti, Jacques; Sauvanet, Alain; Soubrane, Olivier

    2017-09-01

    Lateral injury of the bile duct can occur after cholecystectomy, bile duct dissection, or exploration. If direct repair is not possible, conversion to bilioenteric anastomosis can be needed with the risk of long-term bile duct infections and associated complications. We developed a new surgical technique which consist of reconstructing the bile duct with the round ligament. The vascularized round ligament is completely mobilized until its origin and used for lateral reconstruction of the bile duct to cover the defect. T tube was inserted and removed after few months. Patency of the bile duct was assessed by cholangiography, the liver function test and magnetic resonance imaging (MRI). Two patients aged 33 and 59 years old underwent lateral reconstruction of the bile duct for defects secondary to choledocotomy for stone extraction or during dissection for Mirizzi syndrome. The defects measured 2 and 3 cm and occupied half of the bile duct circumference. The postoperative course was marked by low output biliary fistula resolved spontaneously. In one patient, the T tube was removed at 3 months after surgery and MRI at 9 months showed strictly normal aspect of the bile duct with normal liver function test. The second patient is going very well 2 months after surgery and the T tube is closed. Lateral reconstruction of the bile duct can be safely achieved with the vascularized round ligament. We will extend our indications to tubular reconstruction.

  7. Anatomic variations in intrahepatic bile ducts in a north Indian population.

    PubMed

    Sharma, Vijay; Saraswat, Vivek Anand; Baijal, Sanjay Saran; Choudhuri, Gourdas

    2008-07-01

    In the present study, we described the anatomical variations in the branching patterns of intrahepatic bile ducts (IHD) and determined the frequency of each variation in north Indian patients. There are no data from India. The study group consisted of 253 consecutive patients (131 women) undergoing endoscopic retrograde cholangiograms for different indications. Anatomical variations in IHD were classified according to the branching pattern of the right anterior segmental duct (RASD) and the right posterior segmental duct (RPSD), presence or absence of first-order branch of left hepatic duct (LHD) and of an accessory hepatic duct. Anatomy of the IHD was typical in 52.9% of cases (n = 134), showing triple confluence in 11.46% (n = 29), anomalous drainage of the RPSD into the LHD in 18.2% (n = 46), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 7.1% (n = 18), drainage of the right hepatic duct (RHD) into the cystic duct 0.4% (n = 1), presence of an accessory duct leading to the CHD or RHD in 4.7% (n = 12), individual drainage of the LHD into the RHD or CHD in 2.4% (n = 6), and unclassified or complex variations in 2.7% (n = 7). None had anomalous drainage of RPSD into the cystic duct. The branching pattern of IHD was atypical in 47% patients. The two most common variations were drainage of the RPSD into the LHD (18.2%) and triple confluence of the RASD, RPSD, and LHD (11.5%).

  8. Iatrogenic bile duct strictures: a review of 22 cases.

    PubMed

    Ersumo, Tessema

    2003-10-01

    The incidence of iatrogenic bile duct strictures in Ethiopia appears to be increasing. Of 27 patients that sustained bile duct injuries at open cholecystectomy, admitted during May 1996 to December 2002, 22 cases of bile duct strictures are presented to evaluate outcome of treatment. The mean age was 40 years, 15 females. Twenty-one were referrals. The usual presenting features were biliary peritonitis and jaundice. The average time lapse between the original surgery and admission to hospital was eight months. About 73% had Bismuth grade III-IV strictures and all patients underwent Roux-en-Y hepatico-jejunostomy. Postoperatively, biliary-cutaneous fistula, recurrent ascending cholangitis and wound infection were observed frequently. The overall mortality rate was 13.6%. Bile duct injuries and strictures occur in young productive age groups. Prevention of the occurrence of bile duct injury and its progression to a devastating stricture reduces morbidity and mortality.

  9. Patent vitellointestinal duct as paraumblical abcess: A rare presentation

    PubMed Central

    Rekhi, Harnam Singh; Mittal, Sushil; Singh, Gurtej; Rekhi, Balwinder Kaur; Dugg, Pankaj

    2015-01-01

    Introduction Umbilical and paraumblical abscess can occur in children with presenting complaint of discharge from umbilical region. However, patent vitello intestinal duct presenting as paraumblical abscess is rare phenomenon. Presentation of case One year old male child presented with complain of discharge from umbilical region since birth. Incision & drainage done twice thinking it to be paraumblical abscess. Discussion Vitellointestinal duct as abscess is rare presentation but it should be considered as a differential diagnosis of discharging umbilicus as management of abscess and patent duct are different. Conclusion Patent vitellointestinal duct can present as paraumbilical abscess, and it should be kept in differential diagnosis specifically in children. PMID:26301682

  10. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2010-12-14

    A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.

  11. Comparison of five video-assisted intubation devices by novice and expert laryngoscopists for use in the aeromedical evacuation environment.

    PubMed

    Wallace, Matthew C; Britton, SSgt Tyler; Meek, Robbie; Walsh-Hart, Sharon; Carter, Col Todd E; Lisco, Steven J

    2017-01-01

    The critically ill or injured patient undergoing military medical evacuation may require emergent intubation. Intubation may be life-saving, but it carries risks. The novice or infrequent laryngoscopist has a distinct disadvantage because experience is critical for the rapid and safe establishment of a secured airway. This challenge is compounded by the austere environment of the back of an aircraft under blackout conditions. This study determined which of five different video-assisted intubation devices (VAIDs) was best suited for in-flight use by U.S. Air Force Critical Care Air Transport Teams by comparing time to successful intubation between novice and expert laryngoscopists under three conditions, Normal Airway Lights on (NAL), Difficult Airway Lights on (DAL) and Difficult Airway Blackout (DAB), using manikins on a standard military transport stanchion and the floor with a minimal amount of setup time and extraneous light emission. A convenience sample size of 40 participants (24 novices and 16 experts) attempted intubation with each of the 5 different video laryngoscopic devices on high-fidelity airway manikins. Time to tracheal intubation and number of optimization maneuvers used were recorded. Kruskal-Wallis testing determined significant differences between the VAIDs in time to intubation for each particular scenario. Devices with significant differences underwent pair-wise comparison testing using rank-sum analysis to further clarify the difference. Device assembly times, startup times and the amount of light emitted were recorded. Perceived ease of use was surveyed. Novices were fastest with the Pentax AWS in all difficult airway scenarios. Experts recorded the shortest median times consistently using 3 of the 5 devices. The AWS was superior overall in 4 of the 6 scenarios tested. Experts and novices subjectively judged the GlideScope Ranger as easiest to use. The light emitted by all the devices was less than the USAF-issued headlamp. Novices

  12. Are Ducted Mini-Splits Worth It?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winkler, Jonathan M; Maguire, Jeffrey B; Metzger, Cheryn E.

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within themore » Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).« less

  13. Persistant dysphonia following endotracheal intubation.

    PubMed

    Hamdan, Abdul-Latif; Sabra, Omar; Rameh, Charbel; El-Khatib, Mohamad

    2007-02-01

    Voice production is a complex process that involves more than one system, yet most causes of dysphonia are attributed to disturbances in the laryngeal structures and little attention is paid to extralaryngeal factors. Persistent dysphonia after general anesthesia is a challenge to both anesthesiologists and otolaryngologists. The etiology is often multivariable and necessitates a team approach for proper diagnosis. Laryngeal symptoms are subdivided into phonatory disturbances and airway related complaints. When they become persistent for more than 72 hours or are coupled with airway symptoms such as hemoptysis, stridor, dyspnea or aspiration, the anesthesiologist should suspect injury to the vocal folds or cricoarytenoid joints. Here-below, the laryngeal manifestations of endotracheal intubation and the pathophysiology of vocal fold scarring are discussed.

  14. Detonation duct gas generator demonstration program

    NASA Technical Reports Server (NTRS)

    Wortman, Andrew; Brinlee, Gayl A.; Othmer, Peter; Whelan, Michael A.

    1991-01-01

    The feasibility of the generation of detonation waves moving periodically across high speed channel flow is experimentally demonstrated. Such waves are essential to the concept of compressing requirements and increasing the engine pressure compressor with the objective of reducing conventional compressor requirements and increasing the engine thermodynamic efficiency through isochoric energy addition. By generating transient transverse waves, rather than standing waves, shock wave losses are reduced by an order of magnitude. The ultimate objective is to use such detonation ducts downstream of a low pressure gas turbine compressor to produce a high overall pressure ratio thermodynamic cycle. A 4 foot long, 1 inch x 12 inch cross-section, detonation duct was operated in a blow-down mode using compressed air reservoirs. Liquid or vapor propane was injected through injectors or solenoid valves located in the plenum or the duct itself. Detonation waves were generated when the mixture was ignited by a row of spark plugs in the duct wall. Problems with fuel injection and mixing limited the air speeds to about Mach 0.5, frequencies to below 10 Hz, and measured pressure ratios of about 5 to 6. The feasibility of the gas dynamic compression was demonstrated and the critical problem areas were identified.

  15. Liver and Bile Duct Cancer—Health Professional Version

    Cancer.gov

    Liver cancer includes two major types: hepatocellular carcinoma (HCC) and intrahepatic bile duct cancer, also known as cholangiocarcinoma. Find evidence-based information on liver and bile duct cancer treatment, causes and prevention, screening, research, genomics and statistics.

  16. Large Eddy Simulation of Ducted Propulsors in Crashbac

    NASA Astrophysics Data System (ADS)

    Jang, Hyunchul; Mahesh, Krishnan

    2008-11-01

    Flow around a ducted marine propulsor is computed using the large eddy simulation methodology under crashback conditions. Crashback is an operating condition where a propulsor rotates in the reverse direction while the vessel moves in the forward direction. It is characterized by massive flow separation and highly unsteady propeller loads, which affect both blade life and maneuverability. The simulations are performed on unstructured grids using the algorithm developed by Mahesh at al. (2004, J. Comput. Phys 197). The flow is computed at the advance ratio J=-0.7 and Reynolds number Re=480,000 based on the propeller diameter. Average and RMS values of the unsteady loads such as thrust, torque, and side force on the blades and duct are compared to experiment. It is seen that even though effects of the duct on thrust and torque are not large enough, those on the side force are significant. The rms of side forces is much higher in the presence of the duct. Pressure distributions on blade surfaces and duct surface are examined and used to explain this effect. This work was supported by the United States Office of Naval Research under ONR Grant N00014-05-1-0003.

  17. Endotracheal Intubation with the King Laryngeal Tube™ In Situ Using Video Laryngoscopy and a Bougie: A Retrospective Case Series and Cadaveric Crossover Study.

    PubMed

    Dodd, Kenneth W; Kornas, Rebecca L; Prekker, Matthew E; Klein, Lauren R; Reardon, Robert F; Driver, Brian E

    2017-04-01

    Removal of a functioning King laryngeal tube (LT) prior to establishing a definitive airway increases the risk of a "can't intubate, can't oxygenate" scenario. We previously described a technique utilizing video laryngoscopy (VL) and a bougie to intubate around a well-seated King LT with the balloons deflated; if necessary, the balloons can be rapidly re-inflated and ventilation resumed. Our objective is to provide preliminary validation of this technique. Emergency physicians performed all orotracheal intubations in this two-part study. Part 1 consisted of a historical analysis of VL recordings from emergency department (ED) patients intubated with the King LT in place over a two-year period at our institution. In Part 2, we analyzed VL recordings from paired attempts at intubating a cadaver, first with a King LT in place and then with the device removed, with each physician serving as his or her own control. The primary outcome for all analyses was first-pass success. There were 11 VL recordings of ED patients intubated with the King LT in place (Part 1) and 11 pairs of cadaveric VL recordings (Part 2). The first-pass success rate was 100% in both parts. In Part 1, the median time to intubation was 43 s (interquartile range [IQR] 36-60 s). In Part 2, the median time to intubation was 23 s (IQR 18-35 s) with the King LT in place and 17 s (IQR 14-18 s) with the King LT removed. Emergency physicians successfully intubated on the first attempt with the King LT in situ. The technique described in this proof-of-concept study seems promising and merits further validation. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Is endotracheal intubation a non-beneficial treatment in patients with respiratory failure due to paraquat poisoning?

    PubMed Central

    Wu, Meng-Ruey; Hsiao, Chia-Ying; Cheng, Chun-Han; Liao, Feng-Ching; Chao, Chuan-Lei; Chen, Chun-Yen; Yeh, Hung-I

    2018-01-01

    Introduction Paraquat poisoning can result in dysfunction of multiple organs, and pulmonary fibrosis with respiratory failure is the major cause of mortality. For terminally ill patients, some life-prolonging treatments can be non-beneficial treatments (NBT). The objective of this study was to determine if intubation is a NBT for patients with respiratory failure due to paraquat poisoning. Methods The study included 68 patients with respiratory failure due to paraquat poisoning. Patients were hospitalized at MacKay Memorial Hospital, Taitung Branch, Taiwan, between 2005 to April 2016. Composite outcomes of intra-hospital mortality, the rate of do-not-resuscitate (DNR) orders, prescribed medications, length of stay, and medical costs were recorded and compared between the do-not-intubate (DNI) group and endotracheal intubation (EI) group. Results Intra-hospital mortality rate for the entire population was 100%. There were significantly more patients with DNR orders in the DNI group (P = 0.007). There were no differences in the length of hospital stay. However, patients in DNI group had significantly less vasopressor use and more morphine use, shorter time in the intensive care unit, and fewer medical costs. Conclusion The procedure of intubation in patients with respiratory failure due to paraquat poisoning can be considered inappropriate life-prolonging treatment. PMID:29590187

  19. Cervical spinal motion during intubation: efficacy of stabilization maneuvers in the setting of complete segmental instability.

    PubMed

    Lennarson, P J; Smith, D W; Sawin, P D; Todd, M M; Sato, Y; Traynelis, V C

    2001-04-01

    The purpose of this study was to characterize and compare segmental cervical motion during orotracheal intubation in cadavers with and without a complete subaxial injury, as well as to examine the efficacy of commonly used stabilization techniques in limiting that motion. Intubation procedures were performed in 10 fresh human cadavers in which cervical spines were intact and following the creation of a complete C4-5 ligamentous injury. Movement of the cervical spine during direct laryngoscopy and intubation was recorded using video fluoroscopy and examined under the following conditions: 1) without stabilization; 2) with manual in-line cervical immobilization; and 3) with Gardner-Wells traction. Subsequently, segmental angular rotation, subluxation, and distraction at the injured C4-5 level were measured from digitized frames of the recorded video fluoroscopy. After complete C4-5 destabilization, the effects of attempted stabilization on distraction, angulation, and subluxation were analyzed. Immobilization effectively eliminated distraction, and diminished angulation, but increased subluxation. Traction significantly increased distraction, but decreased angular rotation and effectively eliminated subluxation. Orotracheal intubation without stabilization had intermediate results, causing less distraction than traction, less subluxation than immobilization, but increased angulation compared with either intervention. These results are discussed in terms of both statistical and clinical significance and recommendations are made.

  20. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

    PubMed

    Sitzwohl, Christian; Langheinrich, Angelika; Schober, Andreas; Krafft, Peter; Sessler, Daniel I; Herkner, Harald; Gonano, Christopher; Weinstabl, Christian; Kettner, Stephan C

    2010-11-09

    To determine which bedside method of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity. Prospective randomised blinded study. Department of anaesthesia in tertiary academic hospital. 160 consecutive patients (American Society of Anesthesiologists category I or II) aged 19-75 scheduled for elective gynaecological or urological surgery. Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube was fibreoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. To determine whether the tube was properly positioned in the trachea, in each patient first year residents and experienced anaesthetists were randomly assigned to independently perform bilateral auscultation of the chest (auscultation); observation and palpation of symmetrical chest movements (observation); estimation of the position of the tube by the insertion depth (tube depth); or a combination of all three (all three). Correct and incorrect judgments of endotracheal tube position. 160 patients underwent 320 observations by experienced and inexperienced anaesthetists. First year residents missed endobronchial intubation by auscultation in 55% of cases and performed significantly worse than experienced anaesthetists with this bedside test (odds ratio 10.0, 95% confidence interval 1.4 to 434). With a sensitivity of 88% (95% confidence interval 75% to 100%) and 100%, respectively, tube depth and the three tests combined were significantly more sensitive for detecting endobronchial intubation than auscultation (65%, 49% to 81%) or observation(43%, 25% to 60%) (P<0.001). The four tested methods had the same specificity for ruling out endobronchial intubation (that is, confirming correct tracheal intubation). The average correct tube insertion depth was

  1. Observationally constrained modeling of sound in curved ocean internal waves: examination of deep ducting and surface ducting at short range.

    PubMed

    Duda, Timothy F; Lin, Ying-Tsong; Reeder, D Benjamin

    2011-09-01

    A study of 400 Hz sound focusing and ducting effects in a packet of curved nonlinear internal waves in shallow water is presented. Sound propagation roughly along the crests of the waves is simulated with a three-dimensional parabolic equation computational code, and the results are compared to measured propagation along fixed 3 and 6 km source/receiver paths. The measurements were made on the shelf of the South China Sea northeast of Tung-Sha Island. Construction of the time-varying three-dimensional sound-speed fields used in the modeling simulations was guided by environmental data collected concurrently with the acoustic data. Computed three-dimensional propagation results compare well with field observations. The simulations allow identification of time-dependent sound forward scattering and ducting processes within the curved internal gravity waves. Strong acoustic intensity enhancement was observed during passage of high-amplitude nonlinear waves over the source/receiver paths, and is replicated in the model. The waves were typical of the region (35 m vertical displacement). Two types of ducting are found in the model, which occur asynchronously. One type is three-dimensional modal trapping in deep ducts within the wave crests (shallow thermocline zones). The second type is surface ducting within the wave troughs (deep thermocline zones). © 2011 Acoustical Society of America

  2. Müllerian duct cyst: diagnosis with MR imaging.

    PubMed

    Thurnher, S; Hricak, H; Tanagho, E A

    1988-07-01

    The value of magnetic resonance (MR) imaging in diagnosing clinically suspected müllerian duct cysts was assessed in six patients. MR imaging correctly demonstrated the abnormality to be intraprostatic, consistent with the diagnosis of müllerian duct cysts in four patients, and allowed the diagnosis to be excluded in the other two. The demonstration of prostatic zonal anatomy, the ability to obtain direct images in all three orthogonal planes, and a large field of view make MR imaging valuable in the study of suspected müllerian duct cysts.

  3. Transition duct with late injection in turbine system

    DOEpatents

    LeBegue, Jeffrey Scott; Pentecost, Ronnie Ray; Flanagan, James Scott; Kim, Won -Wook; McMahan, Kevin Weston

    2015-09-15

    A system for supplying an injection fluid to a combustor is disclosed. The system includes a transition duct comprising an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The passage defines a combustion chamber. The system further includes a tube providing fluid communication for the injection fluid to flow through the transition duct and into the combustion chamber.

  4. Regeneratively cooled transition duct with transversely buffered impingement nozzles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Jay A; Lee, Ching-Pang; Crawford, Michael E

    2015-04-21

    A cooling arrangement (56) having: a duct (30) configured to receive hot gases (16) from a combustor; and a flow sleeve (50) surrounding the duct and defining a cooling plenum (52) there between, wherein the flow sleeve is configured to form impingement cooling jets (70) emanating from dimples (82) in the flow sleeve effective to predominately cool the duct in an impingement cooling zone (60), and wherein the flow sleeve defines a convection cooling zone (64) effective to cool the duct solely via a cross-flow (76), the cross-flow comprising cooling fluid (72) exhausting from the impingement cooling zone. In themore » impingement cooling zone an undimpled portion (84) of the flow sleeve tapers away from the duct as the undimpled portion nears the convection cooling zone. The flow sleeve is configured to effect a greater velocity of the cross-flow in the convection cooling zone than in the impingement cooling zone.« less

  5. Rescue ventilation: resolving a "cannot mask ventilate, cannot intubate" situation during exchange of a Combitube for a definitive airway.

    PubMed

    Rich, James M; Mason, Andrew M; Tillmann, H A; Foreman, Michael

    2009-10-01

    Our anesthesia care team was called to care for a patient who was admitted to the emergency department with the esophageal-tracheal double-lumen airway device (Combitube, Tyco Healthcare, Nellcor, Pleasanton, California) in place, which needed to be exchanged for a definitive airway because the patient required an extended period of mechanical ventilation. Several techniques were attempted to exchange the esophageal-tracheal Combitube (ETC) without success. First, we attempted direct laryngoscopy with the ETC in place after deflation of the No. 1 proximal cuff and sweeping the ETC to the left. We were prepared to use bougie-assisted intubation but could not identify any airway anatomy. After removal of the ETC, we unsuccessfully attempted ventilation/intubation with a laryngeal mask airway (LMA Fastrach, LMA North America, San Diego, California). Our third attempt was insertion of another laryngeal mask airway (LMA Unique, LMA North America) with marginal ventilation, but we again experienced unsuccessful intubation using a fiberscope. The ETC was reinserted after each intubation attempt because mask ventilation was impossible. Before proceeding with cricothyrotomy, we repeated direct laryngoscopy but without the ETC in place. We identified the tip of the epiglottis, which allowed for bougie-assisted intubation. This obviated the need for emergency cricothyrotomy.

  6. The effects of nicardipine or esmolol on the onset time of rocuronium and intubation conditions during rapid sequence induction: a randomized double-blind trial.

    PubMed

    Lee, Ji Heui; Kim, Yunkwang; Lee, Kye Hyeok; Rim, Sung Kyu; Lee, Ji Yeon; Lee, Cheong

    2015-06-01

    The main aims of rapid sequence induction (RSI) are prompt and adequate muscle relaxation for tracheal intubation and hemodynamic stability during and after intubation. The purpose of the present study was to investigate the effects of nicardipine and esmolol on the action of rocuronium and intubation conditions during RSI. Adult patients (n = 82) were randomly allocated to one of three groups. One minute prior to the induction of sevoflurane-based general anesthesia, patients received 20 μg/kg of nicardipine (N group; n = 27) or 0.5 mg/kg of esmolol (E group; n = 27), or 5 ml of saline (C group; n = 28). Patients were assessed according to intubation conditions, the onset time of rocuronium, mean arterial pressure (MAP), and heart rate (HR) during RSI. The intubation conditions and score were significantly better in the C and N groups than in the E group (P < 0.001). The onset time of rocuronium was shortened in the N group and prolonged in the E group when compared to the C group (P < 0.001). A significant attenuation in the increase of MAP immediately after intubation was observed in the N group as compared with the C and E groups (P < 0.008). HR was significantly lower in the E group than in the N and C groups (P < 0.01). Pretreatment with nicardipine for RSI improved intubation conditions and shortened the onset time of rocuronium and attenuated changes in MAP after intubation. Esmolol may disturb intubation conditions and the onset of action of rocuronium, despite being effective in alleviating responses of HR after RSI.

  7. Incidence of Connected Consciousness after Tracheal Intubation: A Prospective, International, Multicenter Cohort Study of the Isolated Forearm Technique.

    PubMed

    Sanders, Robert D; Gaskell, Amy; Raz, Aeyal; Winders, Joel; Stevanovic, Ana; Rossaint, Rolf; Boncyk, Christina; Defresne, Aline; Tran, Gabriel; Tasbihgou, Seth; Meier, Sascha; Vlisides, Phillip E; Fardous, Hussein; Hess, Aaron; Bauer, Rebecca M; Absalom, Anthony; Mashour, George A; Bonhomme, Vincent; Coburn, Mark; Sleigh, Jamie

    2017-02-01

    The isolated forearm technique allows assessment of consciousness of the external world (connected consciousness) through a verbal command to move the hand (of a tourniquet-isolated arm) during intended general anesthesia. Previous isolated forearm technique data suggest that the incidence of connected consciousness may approach 37% after a noxious stimulus. The authors conducted an international, multicenter, pragmatic study to establish the incidence of isolated forearm technique responsiveness after intubation in routine practice. Two hundred sixty adult patients were recruited at six sites into a prospective cohort study of the isolated forearm technique after intubation. Demographic, anesthetic, and intubation data, plus postoperative questionnaires, were collected. Univariate statistics, followed by bivariate logistic regression models for age plus variable, were conducted. The incidence of isolated forearm technique responsiveness after intubation was 4.6% (12/260); 5 of 12 responders reported pain through a second hand squeeze. Responders were younger than nonresponders (39 ± 17 vs. 51 ± 16 yr old; P = 0.01) with more frequent signs of sympathetic activation (50% vs. 2.4%; P = 0.03). No participant had explicit recall of intraoperative events when questioned after surgery (n = 253). Across groups, depth of anesthesia monitoring values showed a wide range; however, values were higher for responders before (54 ± 20 vs. 42 ± 14; P = 0.02) and after (52 ± 16 vs. 43 ± 16; P = 0.02) intubation. In patients not receiving total intravenous anesthesia, exposure to volatile anesthetics before intubation reduced the odds of responding (odds ratio, 0.2 [0.1 to 0.8]; P = 0.02) after adjustment for age. Intraoperative connected consciousness occurred frequently, although the rate is up to 10-times lower than anticipated. This should be considered a conservative estimate of intraoperative connected consciousness.

  8. Canalicular laceration repair using a viscoelastic injection to locate and dilate the proximal torn edge.

    PubMed

    Örge, Faruk H; Dar, Suhail A

    2015-06-01

    Canalicular lacerations are common complications of eyelid trauma in the pediatric population. Irrigating air, water, and colored or viscous agents through the intact canaliculus have been suggested to identify the torn proximal edge. We report our experience in repairing canalicular lacerations using a novel viscoelastic injection technique with a Monoka monocanalicular stent. The medical records of patients <18 years of age who underwent repair of a canalicular laceration with a monocanalicular stent using superficial viscoelastic deployment to locate the torn canaliculus were retrospectively reviewed. Demographics, cause of eyelid injury, surgical management using our novel viscoelastic injection technique, and outcome were analyzed. A total of 38 children with lid lacerations were identified, of whom the 17 with canalicular involvement were included (mean age, 6.27 years). Canalicular injury in these 17 was due to dog bite (9 patients) and shearing trauma (8 patients). In 11 patients, the injury was located in the lower lid; in 4, the upper lid; and in 2, combined upper and lower lids. All patients had good anatomic repair and on follow-up had negative dye disappearance tests and were free of tearing. Deploying viscoelastic superficially near, and injecting into the injured canaliculus can improve visualization of the operative field by retracting the surrounding tissue and tamponading any bleeding, which aids in location and dilation of the torn canaliculus initially and in subsequent steps, eases intubation into the lubricated torn canaliculus and nasolacrimal duct, and avoids iatrogenic injury to an uninjured canaliculus. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  9. Heat Transfer in a Superelliptic Transition Duct

    NASA Technical Reports Server (NTRS)

    Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven

    2008-01-01

    Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

  10. Treatment of post-intubation laryngeal granulomas: systematic review and proportional meta-analysis.

    PubMed

    Rimoli, Caroline Fernandes; Martins, Regina Helena Garcia; Catâneo, Daniele Cristina; Imamura, Rui; Catâneo, Antonio José Maria

    2018-04-14

    Laryngeal granulomas post intubation are benign but recurrent lesions. There is no consensus for its treatment. To describe the effectiveness of different treatment modalities for primary or recurrent laryngeal granulomas resulting from endotracheal intubation. Systematic review and proportional meta-analysis. Eligibility criteria - experimental or observational studies with at least five subjects. Outcomes studied - granuloma resolution, recurrence, and time for resolution. Databases used - Pubmed, Embase, Lilacs, and Cochrane. The Stats Direct 3.0.121 program was used. Six studies were selected, with 85 patients. The treatments registered were: antireflux therapy, speech therapy, anti-inflammatory drugs, steroids, antibiotics, zinc sulfate and surgery. 85 patients from six studies had primary treatment: surgery±associations (41 patients), resolution chance 75% (95% CI: 0.3-100%, I 2 =90%), absolute relapse risk 25% (95% CI: 0.2-71%); medical treatment (44 patients), resolution chance 86% (95% CI: 67-97%); and absolute relapse risk 14% (95% CI: 3-33%). There was no significant difference between groups. Three studies, encompassing 19 patients, analyzed secondary treatment (failure or recurrence after primary treatment); three subjects presented new recurrence. The time needed to resolve the lesions varied from immediate, after surgery, to 23 months, for inhaled steroid. There is no evidence of high quality that proves the efficacy of any treatment for laryngeal granulomas resulting from endotracheal intubation. Published by Elsevier Editora Ltda.

  11. Positive predictive value of cholescintigraphy in common bile duct obstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lecklitner, M.L.; Austin, A.R.; Benedetto, A.R.

    1986-09-01

    Technetium-99m DISIDA imaging was employed in 400 patients to differentiate obstruction of the common bile duct from medical and other surgical causes of hyperbilirubinemia. Sequential anterior images demonstrated variable degrees of liver uptake, yet there was no evidence of intrabiliary or extrabiliary radioactivity for at least 4 hr after injection in 25 patients. Twenty-three patients were surgically documented to have complete obstruction of the common bile duct. One patient had hepatitis, and another had sickle cell crisis without bile duct obstruction. The remaining patients had either partial or no obstruction of the common bile duct. We conclude that the presencemore » of liver uptake without evident biliary excretion by 4 hr on cholescintigraphy is highly sensitive and predictive of total obstruction of the common bile duct.« less

  12. Obstetric Anaesthetists' Association and Difficult Airway Society guidelines for the management of difficult and failed tracheal intubation in obstetrics.

    PubMed

    Mushambi, M C; Kinsella, S M; Popat, M; Swales, H; Ramaswamy, K K; Winton, A L; Quinn, A C

    2015-11-01

    The Obstetric Anaesthetists' Association and Difficult Airway Society have developed the first national obstetric guidelines for the safe management of difficult and failed tracheal intubation during general anaesthesia. They comprise four algorithms and two tables. A master algorithm provides an overview. Algorithm 1 gives a framework on how to optimise a safe general anaesthetic technique in the obstetric patient, and emphasises: planning and multidisciplinary communication; how to prevent the rapid oxygen desaturation seen in pregnant women by advocating nasal oxygenation and mask ventilation immediately after induction; limiting intubation attempts to two; and consideration of early release of cricoid pressure if difficulties are encountered. Algorithm 2 summarises the management after declaring failed tracheal intubation with clear decision points, and encourages early insertion of a (preferably second-generation) supraglottic airway device if appropriate. Algorithm 3 covers the management of the 'can't intubate, can't oxygenate' situation and emergency front-of-neck airway access, including the necessity for timely perimortem caesarean section if maternal oxygenation cannot be achieved. Table 1 gives a structure for assessing the individual factors relevant in the decision to awaken or proceed should intubation fail, which include: urgency related to maternal or fetal factors; seniority of the anaesthetist; obesity of the patient; surgical complexity; aspiration risk; potential difficulty with provision of alternative anaesthesia; and post-induction airway device and airway patency. This decision should be considered by the team in advance of performing a general anaesthetic to make a provisional plan should failed intubation occur. The table is also intended to be used as a teaching tool to facilitate discussion and learning regarding the complex nature of decision-making when faced with a failed intubation. Table 2 gives practical considerations of how to

  13. Carcinoids of the common bile duct: a case report and literature review

    PubMed Central

    Ross, Alison C.; Hurley, James B.; Hay, W. Bruce; Rusnak, Conrad H.; Petrunia, Denis M.

    1999-01-01

    Carcinoids of the extrahepatic bile ducts and particularly the common bile duct are extremely rare. A 65-year-old woman presented with obstructive jaundice. Laboratory and imaging studies gave results that were consistent with an obstructing lesion in the common bile duct. In this case, a stent was inserted initially to decompress the bile ducts. Subsequently a laparotomy and pancreaticoduodenectomy were performed and a tissue diagnosis of carcinoid of the common bile duct was made. The patient was well with no evidence of recurrence 17 months postoperatively. The authors believe this is the 19th reported case of an extrahepatic bile duct carcinoid. PMID:10071590

  14. Photoneutron radiation field of ducts in barrier of 15 MV medical electron accelerators

    NASA Astrophysics Data System (ADS)

    Deng, Lei; Zhou, Ning; Chen, Yi-shui; Tu, Yu

    2017-11-01

    Shielding body of the high-energy medical electron accelerators is always penetrated by ducts, which would influence the shielding capability of local barrier. In order to quantitatively analyze the duct's impact on shielding of the photoneutron from 15 MV accelerators, the ambient dose equivalent rate and energy spectrum at the center of a typical duct and the external mouth of duct were calculated based on MCNP program for the first time. The results demonstrate that leakage neutrons at the external mouth of duct are mainly thermal neutron, and its dose rate is decreased with the increase of the intersection angle between duct and wall as well as the reduction of duct diameter. When a duct in a diameter no more than 30 cm penetrates the wall unidirectionally and the inclined Angle (θ) is 60°, neutron dose rate at the external mouth of duct could meet the requirements of protection. At last, according to the calculation results, some suggestions are proposed for the shielding design of ducts in walls.

  15. The statistical evaluation of duct tape end match as physical evidence

    NASA Astrophysics Data System (ADS)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  16. Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport.

    PubMed

    Tennyson, Joseph; Ford-Webb, Tucker; Weisberg, Stacy; LeBlanc, Donald

    2016-11-01

    Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS) transportation. Measurement of endotracheal tube (ETT) cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH 2 O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH 2 O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS) agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. We analyzed data for 55 patients. There was a mean age of 57 years (range 18-90). The mean ETT cuff pressure was 70 (95% CI= [61-80]) cmH 2 O. The mean lies 40 cmH 2 O above the maximum accepted value of 30 cmH 2 O (p<0.0001). Eighty-four percent (84%) of patients encountered had pressures above the recommended maximum. The most frequently recorded pressure was >120 cmH 2 O, the maximum pressure on the analog gauge. Patients presenting to HEMS after intubation by the referral agency (EMS or hospital) have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow. Hospital and EMS providers should

  17. Trypsin level in gallbladder bile and ductitis and width of the cystic duct.

    PubMed

    Vracko, J; Wiechel, K L

    2000-01-01

    The change from laparotomy to laparoscopy for cholecystectomy has raised the question of how to manage concomitant bile duct stones. The present-day interest--and controversy--has focused on a transcystic approach reported to be feasible in 66-96% of cases, but without explaining the necessary prerequisite: the widening of the cystic duct. The cystic duct, wide mainly in patients with bile duct stones, has been reported to be highly variable: from strictured to very wide. The present study aims at comparing the trypsin level in the gallbladder bile and the cystic duct morphology and width in patients with and without bile duct stones. A prospective series of 63 gallstone patients, 30 with and 33 without bile duct stones (controls), underwent cholecystectomy and bile duct clearance. The study includes the trypsin level in the gallbladder bile, the width and morphology of the cystic duct, and the size of the gallstones. The patients with bile duct stones had, in contrast to the controls, higher trypsin levels in the gallbladder bile (P < 0.001) and wider cystic ducts (P < 0.001) with more pronounced signs of chronic ductitis. The obtained results strongly suggest that the increased trypsin level, a sign of reflux of pancreatic juice, caused changes in the cystic duct that facilitate gallstone migration, which also ought to render a transcystic stone extraction feasible.

  18. Agenesis of the gallbladder with hypoplastic cystic duct diagnosed at laparoscopy.

    PubMed

    Kwon, A-Hon; Yanagimoto, Hiroaki; Matsui, Yoichi; Imamura, Atsushi

    2006-08-01

    An 86-year-old man was admitted to our department with complaints of intermittent upper abdominal pain. Ultrasonography of the abdomen showed dilated extrahepatic bile ducts containing stones; however, the gallbladder was not clearly identified. Magnetic resonance cholangiopancreatography showed dilated extrahepatic ducts and choledocholithiasis without gallbladder visualization. The stone extraction was performed with endoscopic sphincterotomy. Three-dimensional images using spiral-computed tomography after intravenous-infusion cholangiography clearly demonstrated an obstruction of the cystic duct. The patient was scheduled for laparoscopic cholecystectomy. At laparoscopy, the gallbladder fossa was not identified on the undersurface of the liver. Despite a thorough examination of the intrahepatic (left-sided within the lesser omentum), retroperitoneal, retrohepatic (within the falciform ligament), retroduodenal, and retropancreatic areas using laparoscopic ultrasonography, the gallbladder was not found. After careful dissection of the hepatoduodenal ligament, the dilated extrahepatic bile duct and a 1-cm length of hypoplastic cystic duct were found. Gallbladder agenesis is usually accompanied by the lack of the cystic duct. The present case is the third report of gallbladder agenesis with a patent or hypoplastic cystic duct.

  19. Design of power-plant installations pressure-loss characteristics of duct components

    NASA Technical Reports Server (NTRS)

    Henry, John R

    1944-01-01

    A correlation of what are believed to be the most reliable data available on duct components of aircraft power-plant installations is presented. The information is given in a convenient form and is offered as an aid in designing duct systems and, subject to certain qualifications, as a guide in estimating their performance. The design and performance data include those for straight ducts; simple bends of square, circular, and elliptical cross sections; compound bends; diverging and converging bends; vaned bends; diffusers; branch ducts; internal inlets; and an angular placement of heat exchangers. Examples are included to illustrate methods of applying these data in analyzing duct systems. (author)

  20. Film condensation in a horizontal rectangular duct

    NASA Technical Reports Server (NTRS)

    Lu, Qing; Suryanarayana, N. V.

    1993-01-01

    Condensation heat transfer in a horizontal rectangular duct was experimentally and analytically investigated. To prevent the dripping of condensate on the film, the experiment was conducted inside a horizontal rectangular duct with vapor condensing only on the bottom cooled plate of the duct. R-113 and FC-72 (Fluorinert Electronic Fluid developed by the 3M Company) were used as the condensing fluids. The experimental program included measurements of film thickness, local and average heat transfer coefficients, wave length, wave speed, and a study of wave initiation. The measured film thickness was used to obtain the local heat transfer coefficient. The wave initiation was studied both with condensation and with an adiabatic air-liquid flow. The test sections used in both experiments were identical.

  1. Family Presence During Pediatric Tracheal Intubations.

    PubMed

    Sanders, Ronald C; Nett, Sholeen T; Davis, Katherine Finn; Parker, Margaret M; Bysani, G Kris; Adu-Darko, Michelle; Bird, Geoffrey L; Cheifetz, Ira M; Derbyshire, Ashley T; Emeriaud, Guillaume; Giuliano, John S; Graciano, Ana Lia; Hagiwara, Yusuke; Hefley, Glenda; Ikeyama, Takanari; Jarvis, J Dean; Kamat, Pradip; Krishna, Ashwin S; Lee, Anthony; Lee, Jan Hau; Li, Simon; Meyer, Keith; Montgomery, Vicki L; Nagai, Yuki; Pinto, Matthew; Rehder, Kyle J; Saito, Osamu; Shenoi, Asha N; Taekema, Hester Christianne; Tarquinio, Keiko M; Thompson, Ann E; Turner, David A; Nadkarni, Vinay M; Nishisaki, Akira

    2016-03-01

    Family-centered care, which supports family presence (FP) during procedures, is now a widely accepted standard at health care facilities that care for children. However, there is a paucity of data regarding the practice of FP during tracheal intubation (TI) in pediatric intensive care units (PICUs). Family presence during procedures in PICUs has been advocated. To describe the current practice of FP during TI and evaluate the association with procedural and clinician (including physician, respiratory therapist, and nurse practitioner) outcomes across multiple PICUs. Prospective cohort study in which all TIs from July 2010 to March 2014 in the multicenter TI database (National Emergency Airway Registry for Children [NEAR4KIDS]) were analyzed. Family presence was defined as a family member present during TI. This study included all TIs in patients younger than 18 years in 22 international PICUs. Family presence and no FP during TI in the PICU. The percentage of FP during TIs. First attempt success rate, adverse TI-associated events, multiple attempts (≥ 3), oxygen desaturation (oxygen saturation as measured by pulse oximetry <80%), and self-reported team stress level. A total of 4969 TI encounters were reported. Among those, 81% (n = 4030) of TIs had documented FP status (with/without). The median age of participants with FP was 2 years and 1 year for those without FP. The average percentage of TIs with FP was 19% and varied widely across sites (0%-43%; P < .001). Tracheal intubations with FP (vs without FP) were associated with older patients (median, 2 years vs 1 year; P = .04), lower Paediatric Index of Mortality 2 score, and pediatric resident as the first airway clinician (23%, n = 179 vs 18%, n = 584; odds ratio [OR], 1.4; 95% CI, 1.2-1.7). Tracheal intubations with FP and without FP were no different in the first attempt success rate (OR, 1.00; 95% CI, 0.85-1.18), adverse TI-associated events (any events: OR, 1.06; 95% CI, 0.85-1.30 and severe events: OR

  2. Intraductal Transanastomotic Stenting in Duct-to-Duct Biliary Reconstruction after Living-Donor Liver Transplantation: A Randomized Trial.

    PubMed

    Santosh Kumar, K Y; Mathew, Johns Shaji; Balakrishnan, Dinesh; Bharathan, Viju Kumar; Thankamony Amma, Binoj Sivasankara Pillai; Gopalakrishnan, Unnikrishnan; Narayana Menon, Ramachandran; Dhar, Puneet; Vayoth, Sudheer Othiyil; Sudhindran, Surendran

    2017-12-01

    Biliary complications continue to be the "Achilles heel" of living-donor liver transplantation (LDLT). The use of biliary stents in LDLT to reduce biliary complications is a controversial issue. We performed a randomized trial to study the impact of intraductal biliary stents on postoperative biliary complications after LDLT. Of the 94 LDLTs that were performed during a period of 16 months, ABO-incompatible transplants, left lobe grafts, 3 or more bile ducts on the graft, and those requiring bilioenteric drainage were excluded. Eligible patients were randomized to either a study arm (intraductal stent, n = 31) or a control arm (no stent, n = 33) by block randomization. Stratification was done, based on the number of ducts on the graft requiring anastomosis, into single (n = 20) or 2 ducts (n = 44). Ureteric stents of 3F to 5F placed across the biliary anastomosis and exiting into the duodenum for later endoscopic removal at 3 months were used. The primary end point was postoperative bile leak. Bile leak occurred in 15 of 64 (23.4%), the incidence was higher in the stented group compared with the control group (35.5% vs 12.1%; p = 0.03). Multiplicity of bile ducts and stenting were identified as risk factors for bile leak on multivariate analysis (p = 0.031 and p = 0.032). During a median follow-up of 2 years, biliary stricture developed in 9 patients (14.1%). Postoperative bile leak is a significant risk factor for the development of biliary stricture (p = 0.003). Intraductal transanastomotic biliary stenting and multiplicity of graft ducts were identified as independent risk factors for the development of postoperative biliary complications. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Measured Performance of a Varied Airflow Small-Diameter Duct System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  4. Measured Performance of a Varied Airflow Small-Diameter Duct System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  5. Tracheal intubation prevented with administration of Fab antivenom after severe crotaline envenomation.

    PubMed

    Bebarta, Vikhyat S; Ferre, Robinson M; Peck, Michael

    2010-07-01

    Crotaline snake envenomations are common, but severe crotaline envenomations are infrequent. Death from severe envenomation is usually from upper airway edema and respiratory failure. Published reports of severe respiratory compromise and anaphylactoid reactions are rare. Currently, FabAV (Crotalidae polyvalent immune Fab [Ovine] [CroFab]) is the mainstay of crotaline envenomation treatment; however, FabAV has been approved for only mild and moderate envenomations. We describe a case of a male with severe systemic effects and airway compromise after crotaline envenomation. The patient's systemic effects and upper airway edema substantially improved after antivenom infusion and before epinephrine administration. Endotracheal intubation was averted, clinical deterioration was avoided, and improvement occurred after prompt FabAV use. Fab antivenom likely prevented endotracheal intubation in our case of severe crotaline envenomation. Published by Elsevier Inc.

  6. Endotracheal Intubation With and Without Night Vision Goggles in a Helicopter and Emergency Room Setting: A Manikin Study.

    PubMed

    Gellerfors, Mikael; Svensén, Christer; Linde, Joacim; Lossius, Hans Morten; Gryth, Dan

    2015-09-01

    Securing the airway by endotracheal intubation (ETI) is a key issue in prehospital critical care. Night vision goggles (NVG) are used by personnel operating in low-light environments. We examined the feasibility of an anesthesiologist performed ETI using NVG in a helicopter setting. Twelve anesthesiologists performed ETI on a manikin in an emergency room (ER) setting and two helicopter settings, with randomization to either rotary wing daylight (RW-D) or rotary wing in total darkness using binocular NVG (RW-NVG). Primary endpoint was intubation time. Secondary endpoints included success rate, Cormack-Lehane (CL) score, and subjective difficulty according to the Visual Analoge Scale (VAS). The median intubation time was shorter for the RW-D compared to the RW-NVG setting (16.5 seconds vs. 30.0 seconds; p = 0,03). We found no difference in median intubation time for the ER and RW-D settings (16.8 seconds vs. 16.5 seconds; p = 0.91). For all scenarios, success rate was 100%. CL and VAS varied between the ER setting (CL 1.8, VAS 2.8), RW-D setting (CL 2.0, VAS 3.0), and RW-NVG setting (CL 3.0, VAS 6.5). This study suggests that anesthesiologists successfully and quickly can perform ETI in a helicopter setting both in daylight and in darkness using binocular NVG, but with shorter intubation times in daylight. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  7. Intubations and airway management: An overview of Hassles through third millennium.

    PubMed

    Alanazi, Abdullah

    2015-01-01

    The placement of a tube into a patient's trachea "the intubation" as we call is not as simple as it looks. It is a very tricky and tedious maneuver that entails skills to assess and perform. Nevertheless, often this is left to the chores of inefficient hands due to a paucity of the availability of experts. They seldom are able to complete the task and often wind up calling the attention of the unit. The present review is an attempt to describe the need to undertake intubation, the procedures and techniques, the complications, including morbidity and mortality and airway management. This overview includes explicit descriptions of the difficult airway which represents multifaceted interface amid patient factors, clinical setting, and skills of the practitioner. To accomplish the target, peer-reviewed English language articles published during third millennium up to 2013 were selected from Pub Med, Pub Med Central, Science Direct, Up-to-date, Med Line, comprehensive databases, Cochrane library, and the Internet (Google, Yahoo). The review constituted a systematic search of literature on the requirements that necessitate the practice of intubation, different techniques that facilitate easy conduct of procedure, the complications, including, morbidity and mortality, and the airway management. Recording every single detail has been beyond the scope of this review, however; some aspects have been wrapped up in nutshell. Some areas of the review are too basic which the medics are well aware of and knowledgeable. Nevertheless, these are difficult to be dispensed with in consideration of their source to the awareness of a common man and a great majority of the patients.

  8. Tracheal injury as a sequence of multiple attempts of endotracheal intubation in the course of a preclinical cardiopulmonary resuscitation.

    PubMed

    Jaeger, K; Ruschulte, H; Osthaus, A; Scheinichen, D; Heine, J

    2000-01-01

    Management of the difficult airway requires an appropriate approach based on personal clinical experiences. For every physician involved in rescue and emergency medicine, it is important to know the difficult airway algorithm and be familiar with alternative techniques of managing the difficult airway. We report a case of tracheal injury caused by multiple attempts at intubating the trachea. Based on current knowledge, apart from surgical equipment for cricothyroidotomy the laryngeal mask airway (LMA) and the Combitube (ETC) should be available on any ambulance vehicle staffed by an emergency physician. In future, blind intubation through the intubating laryngeal mask airway (ILMA) could offer a new opportunity.

  9. Heat Transfer in Conical Corner and Short Superelliptical Transition Ducts

    NASA Technical Reports Server (NTRS)

    Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven

    2008-01-01

    Local surface heat transfer measurements were experimentally mapped using a transient liquid-crystal heat-transfer technique on the surface of two circular-to-rectangular transition ducts. One has a transition cross section defined by conical corners (Duct 1) and the other by an elliptical equation with changing coefficients (Duct 2). Duct 1 has a length-to-diameter ratio of 0.75 and an exit plane aspect ratio of 1.5. Duct 2 has a length-to-diameter ratio of 1.0 and an exit plane aspect ratio of 2.9. Test results are reported for various inlet-diameter-based Reynolds numbers ranging from 0.45 106 to 2.39 106 and two freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

  10. A Review of Double Common Bile Duct and Its Sequelae.

    PubMed

    Kolli, Sindhura; Etienne, Denzil; Reddy, Madhavi; Shahzad, Ghulamullah

    2018-02-01

    A double or accessory common bile duct (ACBD) is a rare congenital anomaly. We report the case of a 60-year-old American Asian male, who was found to have a double or duplicated common bile duct after being admitted for evaluation of a pancreatic mass. A duplicated bile duct has the same mucosa histologically as a single bile duct. However, the opening of a duplicated bile duct lacks a sphincter allowing retrograde flow of gut contents which results in a higher probability of intraductal calculus formation. On rare occasions, it can predispose to liver abscesses, pancreatitis, pancreatic cancer, gallbladder cancer, gastric cancer, and ampullary cancer depending on the location of the opening of the ACBD. We present an integrative review of the limited cases of ACBD with correlation to the current case and discussion regarding the aspects of diagnosis and management.

  11. Tracheal intubation in patients with cervical spine immobilization: A comparison of McGrath(®) video laryngoscope and Truview EVO2(®) laryngoscope.

    PubMed

    Bhola, Ruchi; Bhalla, Swaran; Gupta, Radha; Singh, Ishwar; Kumar, Sunil

    2014-05-01

    Literature suggests that glottic view is better when using McGrath(®) Video laryngoscope and Truview(®) in comparison with McIntosh blade. The purpose of this study was to evaluate the effectiveness of McGrath Video laryngoscope in comparison with Truview laryngoscope for tracheal intubation in patients with simulated cervical spine injury using manual in-line stabilisation. This prospective randomised study was undertaken in operation theatre of a tertiary referral centre after approval from the Institutional Review Board. A total of 100 consenting patients presenting for elective surgery requiring tracheal intubation were randomly assigned to undergo intubation using McGrath(®) Video laryngoscope (n = 50) or Truview(®) (n = 50) laryngoscope. In all patients, we applied manual-in-line stabilisation of the cervical spine throughout the airway management. Statistical testing was conducted with the statistical package for the social science system version SPSS 17.0. Demographic data, airway assessment and haemodynamics were compared using the Chi-square test. A P < 0.05 was considered significant. The time to successful intubation was less with McGrath video laryngoscope when compared to Truview (30.02 s vs. 38.72 s). However, there was no significant difference between laryngoscopic views obtained in both groups. The number of second intubation attempts required and incidence of complications were negligible with both devices. Success rate of intubation with both devices was 100%. Intubation with McGrath Video laryngoscope caused lesser alterations in haemodynamics. Both laryngoscopes are reliable in case of simulated cervical spine injury using manual-in-line stabilisation with 100% success rate and good glottic view.

  12. Sound attenuation of fiberglass lined ventilation ducts

    NASA Astrophysics Data System (ADS)

    Albright, Jacob

    Sound attenuation is a crucial part of designing any HVAC system. Most ventilation systems are designed to be in areas occupied by one or more persons. If these systems do not adequately attenuate the sound of the supply fan, compressor, or any other source of sound, the affected area could be subject to an array of problems ranging from an annoying hum to a deafening howl. The goals of this project are to quantify the sound attenuation properties of fiberglass duct liner and to perform a regression analysis to develop equations to predict insertion loss values for both rectangular and round duct liners. The first goal was accomplished via insertion loss testing. The tests performed conformed to the ASTM E477 standard. Using the insertion loss test data, regression equations were developed to predict insertion loss values for rectangular ducts ranging in size from 12-in x 18-in to 48-in x 48-in in lengths ranging from 3ft to 30ft. Regression equations were also developed to predict insertion loss values for round ducts ranging in diameters from 12-in to 48-in in lengths ranging from 3ft to 30ft.

  13. Flow in curved ducts of varying cross-section

    NASA Astrophysics Data System (ADS)

    Sotiropoulos, F.; Patel, V. C.

    1992-07-01

    Two numerical methods for solving the incompressible Navier-Stokes equations are compared with each other by applying them to calculate laminar and turbulent flows through curved ducts of regular cross-section. Detailed comparisons, between the computed solutions and experimental data, are carried out in order to validate the two methods and to identify their relative merits and disadvantages. Based on the conclusions of this comparative study a numerical method is developed for simulating viscous flows through curved ducts of varying cross-sections. The proposed method is capable of simulating the near-wall turbulence using fine computational meshes across the sublayer in conjunction with a two-layer k-epsilon model. Numerical solutions are obtained for: (1) a straight transition duct geometry, and (2) a hydroturbine draft-tube configuration at model scale Reynolds number for various inlet swirl intensities. The report also provides a detailed literature survey that summarizes all the experimental and computational work in the area of duct flows.

  14. Relationship Between Bile Duct Reconstruction and Complications in Living Donor Liver Transplantation.

    PubMed

    Miyagi, S; Kawagishi, N; Kashiwadate, T; Fujio, A; Tokodai, K; Hara, Y; Nakanishi, C; Kamei, T; Ohuchi, N; Satomi, S

    2016-05-01

    In living donor liver transplantation (LDLT), the recipient bile duct is thin and short. Bile duct complications often occur in LDLT, with persistent long-term adverse effects. Recently, we began to perform microsurgical reconstruction of the bile duct. The purpose of this study was to investigate the relationship between bile duct reconstruction methods and complications in LDLT. From 1991 to 2014, we performed 161 LDLTs (pediatric:adult = 90:71; left lobe:right lobe = 95:66). In this study, we retrospectively investigated the initial bile duct complications in LDLT and performed univariate and multivariate analyses to identify the independent risk factors for complications. The most frequent complication was biliary stricture (9.9%), followed by biliary leakage (6.8%). On univariate and multiple logistic regression analysis, the independent risk factors for biliary stricture were bile leakage (P = .0103) and recurrent cholangitis (P = .0077). However, there were no risk factors for biliary leakage on univariate analysis in our study. The reconstruction methods (hepaticojejunostomy or duct-to-duct anastomosis) and reconstruction technique (with or without microsurgery) were not risk factors for biliary stricture and leakage. In this study, the most frequent complication of LDLT was biliary stricture. The independent risk factors for biliary stricture were biliary leakage and recurrent cholangitis. Duct-to-duct anastomosis and microsurgical reconstruction of the bile duct were not risk factors for biliary stricture and leakage. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Association of prophylactic endotracheal intubation in critically ill patients with upper GI bleeding and cardiopulmonary unplanned events.

    PubMed

    Hayat, Umar; Lee, Peter J; Ullah, Hamid; Sarvepalli, Shashank; Lopez, Rocio; Vargo, John J

    2017-09-01

    Prophylactic endotracheal intubation (PEI) is often advocated to mitigate the risk of cardiopulmonary adverse events in patients presenting with brisk upper GI bleeding (UGIB). However, the benefit of such a measure remains controversial. Our study aimed to compare the incidence of cardiopulmonary unplanned events between critically ill patients with brisk UGIB who underwent endotracheal intubation versus those who did not. Patients aged 18 years or older who presented at Cleveland Clinic between 2011 and 2014 with hematemesis and/or patients with melena with consequential hypovolemic shock were included. The primary outcome was a composite of several cardiopulmonary unplanned events (pneumonia, pulmonary edema, acute respiratory distress syndrome, persistent shock/hypotension after the procedure, arrhythmia, myocardial infarction, and cardiac arrest) occurring within 48 hours of the endoscopic procedure. Propensity score matching was used to match each patient 1:1 in variables that could influence the decision to intubate. These included Glasgow Blatchford Score, Charleston Comorbidity Index, and Acute Physiology and Chronic Health Evaluation scores. Two hundred patients were included in the final analysis. The baseline characteristics, comorbidity scores, and prognostic scores were similar between the 2 groups. The overall cardiopulmonary unplanned event rates were significantly higher in the intubated group compared with the nonintubated group (20% vs 6%, P = .008), which remained significant (P = .012) after adjusting for the presence of esophageal varices. PEI before an EGD for brisk UGIB in critically ill patients is associated with an increased risk of unplanned cardiopulmonary events. The benefits and risks of intubation should be carefully weighed when considering airway protection before an EGD in this group of patients. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  16. Analysis of sound propagation in ducts using the wave envelope concept

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.

    1974-01-01

    A finite difference formulation is presented for sound propagation in a rectangular two-dimensional duct without steady flow for plane wave input. Before the difference equations are formulated, the governing Helmholtz equation is first transformed to a form whose solution does not oscillate along the length of the duct. This transformation reduces the required number of grid points by an order of magnitude, and the number of grid points becomes independent of the sound frequency. Physically, the transformed pressure represents the amplitude of the conventional sound wave. Example solutions are presented for sound propagation in a one-dimensional straight hard-wall duct and in a two-dimensional straight soft-wall duct without steady flow. The numerical solutions show evidence of the existence along the duct wall of a developing acoustic pressure diffusion boundary layer which is similar in nature to the conventional viscous flow boundary layer. In order to better illustrate this concept, the wave equation and boundary conditions are written such that the frequency no longer appears explicitly in them. The frequency effects in duct propagation can be visualized solely as an expansion and stretching of the suppressor duct.

  17. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... between which relative motion could exist must have means for flexibility. (d) For turbine engine and... stage of the engine supercharger and of the auxiliary power unit compressor must have a drain to prevent... compartment to prevent hot gas reverse flow from burning through auxiliary power unit ducts and entering any...

  18. Numerical and experimental investigation of conventional and un-conventional preswirl duct for VLCC

    NASA Astrophysics Data System (ADS)

    Shin, Hyun-Joon; Lee, Jong-Seung; Lee, Kang-Hoon; Han, Myung-Ryun; Hur, Eui-Beom; Shin, Sung-Chul

    2013-09-01

    This paper shows the study of preswirl duct as an effective energy saving devices that have been devised and reviewed to support the propeller performance, especially for the ship of VLCC with large block coefficients. From the bare hull wake measurements, typical upper/lower asymmetry of hull wake at the propeller disk was found. The 2 kinds of pre-swirl duct, Unconventional half circular duct and Conventional circular pre-swirl duct have been designed and reviewed to recover the loss of propeller running in that condition. The general function of the pre-swirl duct was set to work against this asymmetry of wake and generate pre-swirled flow into the propeller against the propeller rotating direction. The optimum self propulsion tests with various angle configurations were carried out and the best configuration was decided. Accordingly, cavitation test was carried out with best configuration of unconventional half circular duct. The blade surface and tip vortex cavitation behaved smoother when the duct was mounted. The hull pressure amplitudes reflected this difference, so the hull pressure amplitude with duct was smaller than that of without duct.

  19. Management of in-tube projectiles using acoustic channel

    NASA Astrophysics Data System (ADS)

    Kostina, M. A.; Bortalevich, S. I.; Loginov, E. L.; Shinyakov, Y. A.; Sukhorukov, M. P.

    2018-03-01

    The article describes the method of measuring the distance from the operator's console installed outside the pipe to the in-tube projectile. A method for measuring distance in the absence of an echo signal is proposed. To do this, two identical ultrasonic locators operating at different frequencies were installed inside and outside the pipeline. The change in the duration of an acoustic pulse propagating in a circular waveguide with rigid walls is shown, which leads to a decrease in the data transfer rate.

  20. SSME 3-D Turnaround Duct flow analysis - CFD predictions

    NASA Technical Reports Server (NTRS)

    Brankovic, Andreja; Stowers, Steven T.; Mcconnaughey, Paul

    1988-01-01

    CFD analysis is presently employed to obtain an improved flowfield for an individual flowpath in the case of the Space Shuttle Main Engine's High Pressure Fuel Turbopump Turn-Around Duct (TAD), which conducts the flow exiting from the gas turbines into the fuel bowl. It is demonstrated that the application of CFD to TAD flow analysis, giving attention to the duct's configuration and to the number, shape, and alignment of the diffuser struts, can enhance understanding of flow physics and result in improved duct design and performance.

  1. Device for temporarily closing duct-formers in well completion apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zandmer, H.M.; Zandmer, S.M.

    A duct-forming device is disclosed for use in a well completion apparatus of the kind, wherein a bore hole casing is positioned in a bore hole and duct-forming devices of alkali- and acid resistant metal-such as steel-are secured at spaced levels to the casing in alignment with holes machined in the casing wall. In accordance with the invention, a closure device is arranged within the duct-forming device which permits flow of predetermined amounts of liquid, such as acid, from the interior of the casing through the duct-forming device and into the producing formation, while gradually being moved by the liquidmore » into a position in which such fluid flow is prevented. After the fluid flow has been stopped by the closure device and when the formation pressure exceeds the pressure within the duct-forming device and the casing, fluid from the formation then forces the closure device toward and into the casing space to permit thereafter free flow of formation fluid into the duct-forming device and the casing or of pressurized treatment liquid from the casing into the formation. The inventive arrangement permits inter alia the establishment of a sufficient and substantially uniform feeding rate of treatment liquid, such as acid, from the casing into the producing formation through all the duct-formers in preparation for subsequent acidification or other treatments, such as sand fracking.« less

  2. Transareolar Single-Port Needlescopic Thoracic Sympathectomy Under Intravenous Anesthesia Without Intubation: A Randomized Controlled Trial.

    PubMed

    Chen, Jianfeng; Du, Quan; Lin, Min; Lin, Jianbo; Li, Xu; Lai, Fancai; Tu, Yuanrong

    2016-12-01

    Transareolar single-port needlescopic thoracic sympathectomy under intravenous anesthesia without intubation has rarely been attempted in managing primary palmar hyperhidrosis (PPH). The objective of this study is to evaluate the feasibility and safety of this minimally invasive technique. From May 2012 to May 2015, 168 male patients with severe PPH underwent single-port endoscopic thoracic sympathectomy (ETS) and were randomly allocated to groups A or B. Patients in group A underwent nonintubated transareolar ETS with a 2-mm needle endoscope, while those in group B underwent intubated transaxillary ETS with a 5-mm thoracoscope. All procedures were performed successfully. The palms of all patients became dry and warm immediately after surgery. The mean resuscitation time was significantly shorter in nonintubated patients than in intubated patients. Postoperative sore throat occurred in 4 patients in group A and in 32 patients in group B (P < .01). The mean incision length was significantly shorter in group A than in group B. The mean postoperative pain scores were markedly higher in group B than in group A. The mean cost of anesthesia was considerably lower in nonintubated patients than in intubated patients. The mean cosmetic scores were higher in group A than in group B (P < .01). Nonintubated transareolar single-port ETS with a needle endoscope is a safe, effective, and minimally invasive therapeutic procedure, which allows a smaller incision with less pain and excellent cosmetic results. This novel procedure can be performed in a routine clinical practice for male patients with severe PPH.

  3. Laparoscopic bile duct injury: understanding the psychology and heuristics of the error.

    PubMed

    Dekker, Sidney W A; Hugh, Thomas B

    2008-12-01

    Bile duct injury is an important unsolved problem of laparoscopic cholecystectomy, occurring with unacceptable frequency even in the hands of experienced surgeons. This suggests that a systemic predisposition to the injury is intrinsic to cholecystectomy and indicates that an analysis of the psychology and heuristics of surgical decision-making in relation to duct identification may be a guide to prevention. Review of published reports on laparoscopic bile duct injury from 1997 to 2007 was carried out. An analysis was also carried out of the circumstances of the injuries in 49 patients who had transection of an extrahepatic bile duct and who were referred for reconstruction or were assessed in a medicolegal context. Special emphasis was placed on identifying the possible psychological aspects of duct misidentification. Review of published work showed an emphasis on the technical aspects of correct identification of the cystic duct, with few papers addressing the heuristics and psychology of surgical decision-making during cholecystectomy. Duct misidentification was the cause of injury in 42 out of the 49 reviewed patients (86%). The injury was not recognized at operation in 70% and delay in recognition persisted into the postoperative period in 57%. Underestimation of risk, cue ambiguity and visual misperception ('seeing what you believe') were important factors in misidentification. Delay in recognition of the injury is a feature consistent with cognitive fixation and plan continuation, which help construct and sustain the duct misidentification during the operation and beyond. Changing the 'culture' of cholecystectomy is probably the most effective strategy for preventing laparoscopic bile duct injury, especially if combined with new technical approaches and an understanding of the heuristics and psychology of the duct misidentification error. Training of surgeons for laparoscopic cholecystectomy should emphasize the need to be alert for cues that the incorrect

  4. Evaluation of the McGrath MAC and Macintosh laryngoscope for tracheal intubation in 2000 patients undergoing general anaesthesia: the randomised multicentre EMMA trial study protocol

    PubMed Central

    Kriege, Marc; Alflen, Christian; Tzanova, Irene; Schmidtmann, Irene; Piepho, Tim; Noppens, Ruediger R

    2017-01-01

    Introduction The direct laryngoscopy technique using a Macintosh blade is the first choice globally for most anaesthetists. In case of an unanticipated difficult airway, the complication rate increases with the number of intubation attempts. Recently, McGrath MAC (McGrath) video laryngoscopy has become a widely accepted method for securing an airway by tracheal intubation because it allows the visualisation of the glottis without a direct line of sight. Several studies and case reports have highlighted the benefit of the video laryngoscope in the visualisation of the glottis and found it to be superior in difficult intubation situations. The aim of this study was to compare the first-pass intubation success rate using the (McGrath) video laryngoscope compared with conventional direct laryngoscopy in surgical patients. Methods and analysis The EMMA trial is a multicentre, open-label, patient-blinded, randomised controlled trial. Consecutive patients requiring tracheal intubation are randomly allocated to either the McGrath video laryngoscope or direct laryngoscopy using the Macintosh laryngoscope. The expected rate of successful first-pass intubation is 95% in the McGrath group and 90% in the Macintosh group. Each group must include a total of 1000 patients to achieve 96% power for detecting a difference at the 5% significance level. Successful intubation with the first attempt is the primary endpoint. The secondary endpoints are the time to intubation, attempts for successful intubation, the necessity of alternatives, visualisation of the glottis using the Cormack & Lehane score and percentage of glottic opening score and definite complications. Ethics and dissemination The project was approved by the local ethics committee of the Medical Association of the Rhineland Palatine state and Westphalia-Lippe. The results of this study will be made available in the form of manuscripts for publication and presentations at national and international meetings. Trial

  5. Mammary duct ectasia: a cause of bloody nipple discharge.

    PubMed Central

    Leung, Alexander K. C.; Kao, C. Pion

    2004-01-01

    We report a 13-year-old girl with bloody nipple discharge as a result of mammary duct ectasia. Our patient is the second reported case of mammary duct ectasia in a pubertal girl. Images Figure 1 PMID:15101674

  6. Large-Eddy Simulation of Crashback in a Ducted Propulsor

    NASA Astrophysics Data System (ADS)

    Jang, Hyunchul; Mahesh, Krishnan

    2011-11-01

    Crashback is an operating condition to quickly stop a propelled vehicle, where the propeller is rotated in the reverse direction to yield negative thrust. The crashback condition is dominated by the interaction of free stream flow with strong reverse flow. Crashback causes highly unsteady loads and flow separation on blade surface. This study uses Large-Eddy Simulation to predict the highly unsteady flow field in crashback for a ducted propulsor. Thrust mostly arises from the blade surface, but most of side-force is generated from the duct surface. Both mean and RMS of pressure are much higher on inner surface of duct, especially near blade tips. This implies that side-force on the ducted propulsor is caused by the blade-duct interaction. Strong tip leakage flow is observed behind the suction side at the tip gap. The physical source of the tip leakage flow is seen to be the large pressure difference between pressure and suction sides. The conditional average during high amplitude event shows that the tip leakage flow and pressure difference are significantly higher. This work is supported by the United States Office of Naval Research under ONR Grant N00014-05-1-0003.

  7. Biliary reconstruction in liver transplant patients with primary sclerosing cholangitis, duct-to-duct or Roux-en-Y?

    PubMed

    Shamsaeefar, Alireza; Shafiee, Mohammad; Nikeghbalian, Saman; Kazemi, Kourosh; Mansorian, Mohsenreza; Motazedian, Nasrin; Afshinnia, Farsad; Geramizadeh, Bita; Malekhosseini, Seyed Ali

    2017-06-01

    Roux-en-Y choledochojejunostomy and duct-to-duct (D-D) anastomosis are biliary reconstruction methods for liver transplantation. However, there is a controversy over which method produces better results. We have compared the outcome of D-D anastomosis vs. Roux-en-Y hepaticojejunostomy in patients with primary sclerosing cholangitis who had undergone liver transplant in Shiraz Organ Transplant Center. The medical records of 405 patients with primary sclerosing cholangitis (PSC) who had undergone liver transplant from 1996 to 2015 were reviewed. Patients were divided into two groups: Roux-en-Y group and D-D group. Morbidity, disease recurrence, and graft and patient survival rates were compared between the two groups. Total of 143 patients underwent a D-D biliary reconstruction, and 260 patients had a Roux-en-Y loop. Biliary complication involved 4.2% of patients from the D-D group, and 3.9% from the Roux-en-Y group (P=. 863). Actuarial 1-, 3-, and 5-year patient survival for D-D and Roux-en-Y group was 92%, 85%, and 74%; and 87%, 83%, and 79%, respectively (P=.384). The corresponding 1-, 3-, and 5-year probability of biliary complication was 97%, 95%, and 92%; and 98%, 97%, and 94%, respectively (P=.61). Duct-to-duct biliary reconstruction in liver transplantation for selected patients with PSC is a good alternative instead of Roux-en-Y biliary reconstruction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Difficult Airway Characteristics Associated with First-Attempt Failure at Intubation Using Video Laryngoscopy in the Intensive Care Unit.

    PubMed

    Joshi, Raj; Hypes, Cameron D; Greenberg, Jeremy; Snyder, Linda; Malo, Josh; Bloom, John W; Chopra, Harsharon; Sakles, John C; Mosier, Jarrod M

    2017-03-01

    Video laryngoscopy has overcome the need to align the anatomic axes to obtain a view of the glottic opening to place a tracheal tube. However, despite this advantage, a large number of attempts are unsuccessful. There are no existing data on anatomic characteristics in critically ill patients associated with a failed first attempt at laryngoscopy when using video laryngoscopy. To identify characteristics associated with first-attempt failure at intubation when using video laryngoscopy in the intensive care unit (ICU). This is an observational study of 906 consecutive patients intubated in the ICU with a video laryngoscope between January 2012 and January 2016 in a single-center academic medical ICU. After each intubation, the operator completed a data collection form, which included information on difficult airway characteristics, device used, and outcome of each attempt. Multivariable regression models were constructed to determine the difficult airway characteristics associated with a failed first attempt at intubation. There were no significant differences in sex, age, reason for intubation, or device used between first-attempt failures and first-attempt successes. First-attempt successes more commonly reported no difficult airway characteristics were present (23.9%; 95% confidence interval [CI], 20.7-27.0% vs. 13.3%; 95% CI, 8.0-18.8%). In logistic regression analysis of the entire 906-patient database, blood in the airway (odds ratio [OR], 2.63; 95% CI, 1.64-4.20), airway edema (OR, 2.85; 95% CI, 1.48-5.45), and obesity (OR, 1.59; 95% CI, 1.08-2.32) were significantly associated with first-attempt failure. Data collection on limited mouth opening and secretions began after the first 133 intubations, and we fit a second logistic model to examine cases in which these additional difficult airway characteristics were collected. In this subset (n = 773), the presence of blood (OR, 2.73; 95% CI, 1.60-4.64), cervical immobility (OR, 3.34; 95% CI, 1.28-8.72), and

  9. Bile Duct Cancer (Cholangiocarcinoma) Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version

    Cancer.gov

    Bile duct cancer, or cholangiocarcinoma, is rare. Bile ducts are tubes that carry bile between the liver, gallbladder, and small intestine. Bile duct cancer can occur in the intrahepatic, perihilar (Klatskin tumor), or distal extrahepatic area. Learn about tests to diagnose and the stages of bile duct cancer.

  10. Designing insulation for cryogenic ducts

    NASA Astrophysics Data System (ADS)

    Love, C. C.

    1984-03-01

    It is pointed out that the great temperature difference between the outside of a cryogenic duct and the liquified gas it carries can cause a high heat input unless blocked by a high thermal resistance. High thermal resistance for lines needing maximum insulation is provided by metal vacuum jackets. Low-density foam is satisfactory in cases in which higher heat input can be tolerated. Attention is given to the heat transfer through a duct vacuum jacket, the calculation of heat input and the exterior surface's steady-state temperature for various thicknesses of insulation, the calculation of the heat transfer through gimbal jackets, and design specifications regarding the allowable pressure rise in the jacket's annular space.

  11. Modified duval procedure for small-duct chronic pancreatitis without head dominance.

    PubMed

    Oida, Takatsugu; Aramaki, Osamu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao

    2011-01-01

    In the case of small-duct chronic pancreatitis, surgery for pain relief is broadly divided into resection and drainage procedures. These procedures should be selected according to the location of dominant lesion, diameter of the pancreatic duct and extent of the disease. The appropriate procedure for the treatment of small-duct chronic pancreatitis, especially small-duct chronic pancreatitis without head dominance, remains controversial. We developed the modified Duval procedure for the treatment of small-duct chronic pancreatitis without head dominance and determined the efficacy of this procedure. We retrospectively studied 14 patients who underwent surgical drainage with or without pancreatic resection for chronic pancreatitis with small pancreatic duct (<7mm) without head dominance. These patients were divided into 2 groups; the modified Puestow procedure group and the modified Duval procedure group. No complications occurred in the modified Duval group. In the modified Puestow procedure group, complete and partial pain relief were observed in 62.5%, and 37.5% of patients respectively. In contrast, complete pain relief was observed in all the patients in the modified Duval procedure group. Our modified Duval procedure is useful and should be considered the appropriate surgical technique for the treatment of small-duct chronic pancreatitis without head dominance.

  12. Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study.

    PubMed

    Schuerner, Philipp; Grande, Bastian; Piegeler, Tobias; Schlaepfer, Martin; Saager, Leif; Hutcherson, Matthew T; Spahn, Donat R; Ruetzler, Kurt

    2016-01-01

    Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been introduced to better visualize the vocal cords and accelerate intubation, which makes endotracheal intubation much safer and may contribute to intubation success. Therefore, we aimed to compare hands-off time and intubation success of direct laryngoscopy with videolaryngoscopy (C-MAC, Karl Storz, Tuttlingen, Germany) in a randomized, cross-over manikin study. Twenty-six anesthesia residents and twelve anesthesia consultants of the University Hospital Zurich were recruited through a voluntary enrolment. All participants performed endotracheal intubation using direct laryngoscopy and C-MAC in a random order during ongoing chest compressions. Participants were strictly advised to stop chest compression only if necessary. The median hands-off time was 1.9 seconds in direct laryngoscopy, compared to 3 seconds in the C-MAC group. In direct laryngoscopy 39 intubation attempts were recorded, resulting in an overall first intubation attempt success rate of 97%, compared to 38 intubation attempts and 100% overall first intubation attempt success rate in the C-MAC group. As a conclusion, the results of our manikin-study demonstrate that video laryngoscopes might not be beneficial compared to conventional, direct laryngoscopy in easily accessible airways under CPR conditions and in experienced hands. The benefits of video laryngoscopes are of course more distinct in overcoming difficult airways, as it converts a potential "blind intubation" into an intubation under visual control.

  13. The Primary Duct of Bothrops jararaca Glandular Apparatus Secretes Toxins

    PubMed Central

    Sakai, Fernanda; Portes-Junior, José Antonio; Godoy Viana, Luciana; Mendes Carneiro, Sylvia; Perales, Jonas; Yamanouye, Norma

    2018-01-01

    Despite numerous studies concerning morphology and venom production and secretion in the main venom gland (and some data on the accessory gland) of the venom glandular apparatus of Viperidae snakes, the primary duct has been overlooked. We characterized the primary duct of the Bothrops jararaca snake by morphological analysis, immunohistochemistry and proteomics. The duct has a pseudostratified epithelium with secretory columnar cells with vesicles of various electrondensities, as well as mitochondria-rich, dark, basal, and horizontal cells. Morphological analysis, at different periods after venom extraction, showed that the primary duct has a long cycle of synthesis and secretion, as do the main venom and accessory glands; however, the duct has a mixed mode venom storage, both in the lumen and in secretory vesicles. Mouse anti-B. jararaca venom serum strongly stained the primary duct’s epithelium. Subsequent proteomic analysis revealed the synthesis of venom toxins—mainly C-type lectin/C-type lectin-like proteins. We propose that the primary duct’s toxin synthesis products complement the final venom bolus. Finally, we hypothesize that the primary duct and the accessory gland (components of the venom glandular apparatus) are part of the evolutionary path from a salivary gland towards the main venom gland. PMID:29533989

  14. Sound Radiation from a Supersonic Jet Passing Through a Partially Open Exhaust Duct

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2011-01-01

    The radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet of 25.4 mm exit diameter flowing through a partially open rigid-walled duct with an upstream i-deflector has been studied experimentally. In the experiments, the nozzle is mounted vertically, with the nozzle exit plane at a height of 73 jet diameters above ground level. Relative to the nozzle exit plane (NEP), the location of the duct inlet is varied at 10, 5, and -1 jet diameters. Far-field sound pressure levels were obtained at 54 jet diameters above ground with the aid of acoustic sensors equally spaced around a circular arc of radius equal to 80 jet diameters from the jet axis. Data on the jet acoustic field for the partially open duct were obtained and compared with those with a free jet and with a closed duct. The results suggest that for the partially open duct the overall sound pressure level (OASPL) decreases as the distance between the NEP and the duct inlet plane decreases, while the opposite trend is observed for the closed duct. It is also concluded that the observed peak frequency in the partially open duct increases above the free jet value as the angle from the duct axis is increased, and as the duct inlet plane becomes closer to the NEP.

  15. Evaluation of several non-reflecting computational boundary conditions for duct acoustics

    NASA Technical Reports Server (NTRS)

    Watson, Willie R.; Zorumski, William E.; Hodge, Steve L.

    1994-01-01

    Several non-reflecting computational boundary conditions that meet certain criteria and have potential applications to duct acoustics are evaluated for their effectiveness. The same interior solution scheme, grid, and order of approximation are used to evaluate each condition. Sparse matrix solution techniques are applied to solve the matrix equation resulting from the discretization. Modal series solutions for the sound attenuation in an infinite duct are used to evaluate the accuracy of each non-reflecting boundary conditions. The evaluations are performed for sound propagation in a softwall duct, for several sources, sound frequencies, and duct lengths. It is shown that a recently developed nonlocal boundary condition leads to sound attenuation predictions considerably more accurate for short ducts. This leads to a substantial reduction in the number of grid points when compared to other non-reflecting conditions.

  16. Ability of paramedics to perform endotracheal intubation during continuous chest compressions: a randomized cadaver study comparing Pentax AWS and Macintosh laryngoscopes.

    PubMed

    Truszewski, Zenon; Czyzewski, Lukasz; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Madziala, Marcin; Szarpak, Lukasz

    2016-09-01

    The aim of the trial was to compare the time parameters for intubation with the use of the Macintosh (MAC) laryngoscope and Pentax AWS-S100 videolaryngoscope (AWS; Pentax Corporation, Tokyo, Japan) with and without chest compression (CC) by paramedics during simulated cardiopulmonary resuscitation in a cadaver model. This was a randomized crossover cadaver trial. Thirty-five paramedics with no experience in videolaryngoscopy participated in the study. They performed intubation in two emergency scenarios: scenario A, normal airway without CC; scenario B, normal airway with continuous CC. The median time to first ventilation with the use of the AWS and the MAC was similar in scenario A: 25 (IQR, 22-27) seconds vs. 24 (IQR, 22.5-26) seconds (P=.072). A statistically significant difference in TTFV between AWS and MAC was noticed in scenario B (P=.011). In scenario A, the first endotracheal intubation (ETI) attempt success rate was achieved in 97.1% with AWS compared with 94.3% with MAC (P=.43). In scenario B, the success rate after the first ETI attempt with the use of the different intubation methods varied and amounted to 88.6% vs. 77.1% for AWS and MAC, respectively (P=.002). The Pentax AWS offered a superior glottic view as compared with the MAC laryngoscope, which was associated with a higher intubation rate and a shorter intubation time during an uninterrupted CC scenario. However, in the scenario without CC, the results for AWS and MAC were comparable. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Asymptomatic T-tube remnant in common bile duct.

    PubMed

    Rozario, A; Thomas, P G; Pais, A; Ravindra, K V; Rao, V

    1999-01-01

    A 46-year-old lady presented with itching, five years after a primary common bile duct repair following cholecystectomy. Prior to this she underwent an interno-external biliary drainage. At laparotomy the horizontal limb of a T-tube was found in the common hepatic duct. Eleven months after a Roux loop hepatico-jejunostomy she is asymptomatic.

  18. Acoustic theory of axisymmetric multisectioned ducts. [reduction of turbofan engine noise

    NASA Technical Reports Server (NTRS)

    Zorumski, W. E.

    1974-01-01

    Equations are developed for the acoustic field in a duct system which is made up of a number of connected circular and annular ducts. These equations are suitable for finding the acoustic field inside of and radiated from an aircraft turbofan engine. Acoustic modes are used as generalized coordinates in order to develop a set of matrix equations for the acoustic field. Equations for these modes are given for circular and annular ducts with uniform flow. Modal source equations are derived for point acoustic sources. General equations for mode transmission and reflection are developed and detailed equations are derived for ducts with multiple sections of acoustic treatment and for ducts with circumferential splitter rings. The general theory is applied to the special case of a uniform area circular duct with multisection liners and it is shown that the mode reflection effects are proportional to differences of the acoustic admittances of adjacent liners. A numerical example is given which shows that multisection liners may provide greater noise suppression than uniform liners.

  19. Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.

    PubMed

    Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru

    2015-01-01

    A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.

  20. Active noise control in a duct to cancel broadband noise

    NASA Astrophysics Data System (ADS)

    Chen, Kuan-Chun; Chang, Cheng-Yuan; Kuo, Sen M.

    2017-09-01

    The paper presents cancelling duct noises by using the active noise control (ANC) techniques. We use the single channel feed forward algorithm with feedback neutralization to realize ANC. Several kinds of ducts noises including tonal noises, sweep tonal signals, and white noise had investigated. Experimental results show that the proposed ANC system can cancel these noises in a PVC duct very well. The noise reduction of white noise can be up to 20 dB.