Sample records for nasvytis multiroller traction

  1. Multiroller traction drive speed reducer: Evaluation for automotive gas turbine engine

    NASA Technical Reports Server (NTRS)

    Rohn, D. A.; Anderson, N. E.; Loewenthal, S. H.

    1982-01-01

    Tests were conducted on a nominal 14:1 fixed-ratio Nasvytis multiroller traction drive retrofitted as the speed reducer in an automotive gas turbine engine. Power turbine speeds of 45,000 rpm and a drive output power of 102 kW (137 hp) were reached. The drive operated under both variable roller loading (proportional to torque) and fixed roller loading (automatic loading mechanism locked). The drive operated smoothly and efficiently as the engine speed reducer. Engine specific fuel consumption with the traction speed reducer was comparable to that with the original helical gearset.

  2. Life analysis of multiroller planetary traction drive

    NASA Technical Reports Server (NTRS)

    Coy, J. J.; Rohn, D. A.; Loewenthal, S. H.

    1981-01-01

    A contact fatigue life analysis was performed for a constant ratio, Nasvytis Multiroller Traction Drive. The analysis was based on the Lundberg-Palmgren method for rolling element bearing life prediction. Life adjustment factors for materials, processing, lubrication and traction were included. The 14.7 to 1 ratio drive consisted of a single stage planetary configuration with two rows of stepped planet rollers of five rollers per row, having a roller cluster diameter of approximately 0.21 m, a width of 0.06 m and a weight of 9 kg. Drive system 10 percent life ranged from 18,800 hours at 16.6 kW (22.2 hp) and 25,000 rpm sun roller speed, to 305 hours at maximum operating conditions of 149 kw (200 hp) and 75,000 rpm sun roller speed. The effect of roller diameter and roller center location on life were determined. It was found that an optimum life geometry exists.

  3. Parametric tests of a traction drive retrofitted to an automotive gas turbine

    NASA Technical Reports Server (NTRS)

    Rohn, D. A.; Lowenthal, S. H.; Anderson, N. E.

    1980-01-01

    The results of a test program to retrofit a high performance fixed ratio Nasvytis Multiroller Traction Drive in place of a helical gear set to a gas turbine engine are presented. Parametric tests up to a maximum engine power turbine speed of 45,500 rpm and to a power level of 11 kW were conducted. Comparisons were made to similar drives that were parametrically tested on a back-to-back test stand. The drive showed good compatibility with the gas turbine engine. Specific fuel consumption of the engine with the traction drive speed reducer installed was comparable to the original helical gearset equipped engine.

  4. Advances in traction drive technology

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Anderson, N. E.; Rohn, D. A.

    1983-01-01

    Traction drives are traced from early uses as main transmissions in automobiles at the turn of the century to modern, high-powered traction drives capable of transmitting hundreds of horsepower. Recent advances in technology are described which enable today's traction drive to be a serious candidate for off-highway vehicles and helicopter applications. Improvements in materials, traction fluids, design techniques, power loss and life prediction methods will be highlighted. Performance characteristics of the Nasvytis fixed-ratio drive are given. Promising future drive applications, such as helicopter main transmissions and servo-control positioning mechanisms are also addressed.

  5. Long-Life, Lightweight, Multi-Roller Traction Drives for Planetary Vehicle Surface Exploration

    NASA Technical Reports Server (NTRS)

    Klein, Richard C.; Fusaro, Robert L.; Dimofte, Florin

    2012-01-01

    NASA s initiative for Lunar and Martian exploration will require long lived, robust drive systems for manned vehicles that must operate in hostile environments. The operation of these mechanical drives will pose a problem because of the existing extreme operating conditions. Some of these extreme conditions include operating at a very high or very cold temperature, operating over a wide range of temperatures, operating in very dusty environments, operating in a very high radiation environment, and operating in possibly corrosive environments. Current drive systems use gears with various configurations of teeth. These gears must be lubricated with oil (or grease) and must have some sort of a lubricant resupply system. For drive systems, oil poses problems such as evaporation, becoming too viscous and eventually freezing at cold temperatures, being too thin to lubricate at high temperatures, being degraded by the radiation environment, being contaminated by the regolith (soil), and if vaporized (and not sealed), it will contaminate the regolith. Thus, it may not be advisable or even possible to use oil because of these limitations. An oil-less, compact traction vehicle drive is a drive designed for use in hostile environments like those that will be encountered on planetary surfaces. Initially, traction roller tests in vacuum were conducted to obtain traction and endurance data needed for designing the drives. From that data, a traction drive was designed that would fit into a prototype lunar rover vehicle, and this design data was used to construct several traction drives. These drives were then tested in air to determine their performance characteristics, and if any final corrections to the designs were necessary. A limitation with current speed reducer systems such as planetary gears and harmonic drives is the high-contact stresses that occur at tooth engagement and in the harmonic drive wave generator interface. These high stresses induce high wear of solid

  6. Multirole cargo aircraft options and configurations

    NASA Technical Reports Server (NTRS)

    Conner, D. W.; Vaughan, J. C., III

    1979-01-01

    The paper discusses multirole cargo aircraft options and configurations. It was shown that derivatives of current wide-body aircraft would be economically attractive through 2008, but new dedicated airfreighters incorporating 1990 technology would offer little or no economic incentive. Option studies indicate that Mach 0.7 propfans would be economically attractive in trip cost, aircraft price, and airline ROI; spanloaders would be lower priced with higher ROI, but would have a relatively higher trip cost because of aerodynamic inefficiencies. Finally, air cushion landing gear configurations are identified as an option for avoiding runway constraints on airport accommodation of very large airfreighters.

  7. Traction behavior of two traction lubricants

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Rohn, D. A.

    1983-01-01

    In the analysis of rolling-sliding concentrated contacts, such as gears, bearings and traction drives, the traction characteristics of the lubricant are of prime importance. The elastic shear modulus and limiting shear stress properties of the lubricant dictate the traction/slip characteristics and power loss associated with an EHD contact undergoing slip and/or spin. These properties can be deducted directly from the initial slope m and maximum traction coefficient micron of an experimental traction curve. In this investigation, correlation equations are presented to predict m and micron for two modern traction fluids based on the regression analysis of 334 separate traction disk machine experiments. The effects of contact pressure, temperature, surface velocity, ellipticity ratio are examined. Problems in deducing lubricant shear moduli from disk machine tests are discussed.

  8. Multi-Role Project (MRP): A New Project-Based Learning Method for STEM

    ERIC Educational Resources Information Center

    Warin, Bruno; Talbi, Omar; Kolski, Christophe; Hoogstoel, Frédéric

    2016-01-01

    This paper presents the "Multi-Role Project" method (MRP), a broadly applicable project-based learning method, and describes its implementation and evaluation in the context of a Science, Technology, Engineering, and Mathematics (STEM) course. The MRP method is designed around a meta-principle that considers the project learning activity…

  9. Regression analysis of traction characteristics of traction fluids

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Rohn, D. A.

    1983-01-01

    Traction data for Santotrac 50 and TDF-88 over a wide range of operating conditions were analyzed. An eight term correlation equation to predict the maximum traction coefficient and a six term correlation equation to predict the initial slope of the traction curve were developed. The slope correlation was corrected for size effect considering the compliance of the disks. The effects of different operating conditions on the traction performance of each traction fluid were studied. Both fluids exhibited a loss in traction with increases in spin, but the losses with the TDF-88 fluid were not as severe as those with Santotrac 50. Overall, both fluids exhibited similar performance, showing an increase in traction with contact pressure up to about 2.0 GPa, and a reduction in traction with higher surface speeds up to about 100 m/sec. The apparent stiffness of the traction contact, that is, film disk combination, increases with contact pressure and decreases with speed.

  10. Elastic model of the traction behavior of two traction lubricants

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Rohn, D. A.

    1984-01-01

    In the analysis of rolling-sliding concentrated contacts, such as gears, bearings and traction drives, the traction characteristics of the lubricant are of prime importance. The elastic shear modulus and limiting shear stress properties of the lubricant dictate the traction/slip characteristics and power loss associated with an EHD contact undergoing slip and/or spin. These properties can be deducted directly from the initial slope m and maximum traction coefficient micron of an experimental traction curve. In this investigation, correlation equations are presented to predict m and micron for two modern traction fluids based on the regression analysis of 334 separate traction disk machine experiments. The effects of contact pressure, temperature, surface velocity, ellipticity ratio are examined. Problems in deducing lubricant shear moduli from disk machine tests are discussed. Previously announced in STAR as N83-20116

  11. Not a Pound for Air-To-Ground: A Historiographical Analysis on the Genesis of the Multi-Role Fighter

    DTIC Science & Technology

    2015-04-01

    Sabres .77 Because of their air superiority role, the F-86s did not perform multi-role missions until February 1953 where their bombing was just as...accurate as the slower jets.78 Despite its limited air-to-ground experience, Fifth Air Force “considered the Sabre the

  12. Footwear traction and lower extremity noncontact injury.

    PubMed

    Wannop, John W; Luo, Geng; Stefanyshyn, Darren J

    2013-11-01

    Football is the most popular high school sport; however, it has the highest rate of injury. Speculation has been prevalent that foot fixation due to high footwear traction contributes to injury risk. Therefore, the purpose of the study was to determine whether a relationship exists between the athlete's specific footwear traction (measured with their own shoes on the field of play) and lower extremity noncontact injury in high school football. For 3 yr, 555 high school football athletes had their footwear traction measured on the actual field of play at the start of the season, and any injury the athletes suffered during a game was recorded. Lower extremity noncontact injury rates, grouped based on the athlete's specific footwear traction (both translational and rotational), were compared. For translational traction, injury rate reached a peak of 23.3 injuries/1000 game exposures within the midrange of translational traction, before decreasing to 5.0 injuries/1000 game exposures in the high range of traction. For rotational traction, there was a steady increase in injury rate as footwear traction increased, starting at 4.2 injuries/1000 game exposures at low traction and reaching 19.2 injuries/1000 game exposures at high traction. A relationship exists between footwear traction and noncontact lower extremity injury, with increases in rotational traction leading to a greater injury rate and increases in translational traction leading to a decrease in injury. It is recommended that athletes consider selecting footwear with the lowest rotational traction values for which no detriment in performance results.

  13. Traction contact performance evaluation at high speeds

    NASA Technical Reports Server (NTRS)

    Tevaarwerk, J. L.

    1981-01-01

    The results of traction tests performed on two fluids are presented. These tests covered a pressure range of 1.0 to 2.5 GPa, an inlet temperature range of 30 'C to 70 'C, a speed range of 10 to 80 m/sec, aspect ratios of .5 to 5 and spin from 0 to 2.1 percent. The test results are presented in the form of two dimensionless parameters, the initial traction slope and the maximum traction peak. With the use of a suitable rheological fluid model the actual traction curves measured can now be reconstituted from the two fluid parameters. More importantly, the knowledge of these parameters together with the fluid rheological model, allow the prediction of traction under conditions of spin, slip and any combination thereof. Comparison between theoretically predicted traction under these conditions and those measured in actual traction tests shows that this method gives good results.

  14. Counter traction makes endoscopic submucosal dissection easier.

    PubMed

    Oyama, Tsuneo

    2012-11-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable counter traction thereby making ESD more efficient and safe. The author published this method in 2002. The name ESD was not established in those days; the name cutting endoscopic mucosal resection (EMR) or EMR with hook knife was used. The other traction methods such as external grasping forceps, internal traction, double channel scope, and double scopes method are introduced in this paper. A good strategy for creating counter traction makes ESD easier.

  15. Rolling, slip and traction measurements on low modulus materials

    NASA Technical Reports Server (NTRS)

    Tevaarwerk, J. L.

    1985-01-01

    Traction and wear tests were performed on six low modulus materials (LMM). Three different traction tests were performed to determine the suitability of the material for use as traction rollers. These were the rolling, slip and endurance traction tests. For each material the combination LMM on LMM and LMM on steel were evaluated. Rolling traction test were conducted to determine the load - velocity limits, the rolling traction coefficient of the materials and to establish the type of failures that would result when loading beyond the limit. It was found that in general a simple constant rolling traction coefficient was enough to describe the results of all the test. The slip traction tests revealed that the peak traction coefficients were considerably higher than for lubricated traction contacts. The endurance traction tests were performed to establish the durability of the LMM under conditions of prolonged traction. Wear measurements were performed during and after the test. Energetic wear rates were determined from the wear measurements conducted in the endurance traction tests. These values show that the roller wear is not severe when reasonable levels of traction are transmitted.

  16. Elements affecting runway traction

    NASA Technical Reports Server (NTRS)

    Horne, W. B.

    1974-01-01

    The five basic elements affecting runway traction for jet transport aircraft operation are identified and described in terms of pilot, aircraft system, atmospheric, tire, and pavement performance factors or parameters. Where possible, research results are summarized, and means for restoring or improving runway traction for these different conditions are discussed.

  17. Spin analysis of concentrated traction contacts

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.

    1983-01-01

    Spin, the result of a mismatch in contact radii on either side of the point of rolling, has a detrimental effect on traction contact performance. It occurs in concentrated contacts having conical or contoured rolling elements, such as those in traction drives or angular contact bearings, and is responsible for an increase in contact heating and power loss. The kinematics of spin producing contact geometries and the subsequent effect on traction and power loss are investigated. The influence of lubricant traction characteristics and contact geometries that minimize spin are also addressed.

  18. Application of traction drives as servo mechanisms

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Rohn, D. A.; Steinetz, B. M.

    1985-01-01

    The suitability of traction drives for a wide class of aerospace control mechanisms is examined. Potential applications include antenna or solar array drive positioners, robotic joints, control moment gyro (CMG) actuators and propeller pitch change mechanisms. In these and similar applications the zero backlash, high torsional stiffness, low hysteresis and torque ripple characteristics of traction drives are of particular interest, as is the ability to run without liquid lubrication in certain cases. Wear and fatigue considerations for wet and dry operation are examined along with the tribological performance of several promising self lubricating polymers for traction contracts. The speed regulation capabilities of variable ratio traction drives are reviewed. A torsional stiffness analysis described suggests that traction contacts are relatively stiff compared to gears and are significantly stiffer than the other structural elements in the prototype CMG traction drive analyzed. Discussion is also given of an advanced turboprop propeller pitch change mechanism that incorporates a traction drive.

  19. Traction forces during collective cell motion.

    PubMed

    Gov, N S

    2009-08-01

    Collective motion of cell cultures is a process of great interest, as it occurs during morphogenesis, wound healing, and tumor metastasis. During these processes cell cultures move due to the traction forces induced by the individual cells on the surrounding matrix. A recent study [Trepat, et al. (2009). Nat. Phys. 5, 426-430] measured for the first time the traction forces driving collective cell migration and found that they arise throughout the cell culture. The leading 5-10 rows of cell do play a major role in directing the motion of the rest of the culture by having a distinct outwards traction. Fluctuations in the traction forces are an order of magnitude larger than the resultant directional traction at the culture edge and, furthermore, have an exponential distribution. Such exponential distributions are observed for the sizes of adhesion domains within cells, the traction forces produced by single cells, and even in nonbiological nonequilibrium systems, such as sheared granular materials. We discuss these observations and their implications for our understanding of cellular flows within a continuous culture.

  20. Structural design optimization with survivability dependent constraints application: Primary wing box of a multi-role fighter

    NASA Technical Reports Server (NTRS)

    Dolvin, Douglas J.

    1992-01-01

    The superior survivability of a multirole fighter is dependent upon balanced integration of technologies for reduced vulnerability and susceptability. The objective is to develop a methodology for structural design optimization with survivability dependent constraints. The design criteria for optimization will be survivability in a tactical laser environment. The following analyses are studied to establish a dependent design relationship between structural weight and survivability: (1) develop a physically linked global design model of survivability variables; and (2) apply conventional constraints to quantify survivability dependent design. It was not possible to develop an exact approach which would include all aspects of survivability dependent design, therefore guidelines are offered for solving similar problems.

  1. 3D Viscoelastic Traction Force Microscopy

    PubMed Central

    Toyjanova, Jennet; Hannen, Erin; Bar-Kochba, Eyal; Darling, Eric M.; Henann, David L.; Franck, Christian

    2014-01-01

    Native cell-material interactions occur on materials differing in their structural composition, chemistry, and physical compliance. While the last two decades have shown the importance of traction forces during cell-material interactions, they have been almost exclusively presented on purely elastic in-vitro materials. Yet, most bodily tissue materials exhibit some level of viscoelasticity, which could play an important role in how cells sense and transduce tractions. To expand the realm of cell traction measurements and to encompass all materials from elastic to viscoelastic, this paper presents a general, and comprehensive approach for quantifying 3D cell tractions in viscoelastic materials. This methodology includes the experimental characterization of the time-dependent material properties for any viscoelastic material with the subsequent mathematical implementation of the determined material model into a 3D traction force microscopy (3D TFM) framework. Utilizing this new 3D viscoelastic TFM (3D VTFM) approach, we quantify the influence of viscosity on the overall material traction calculations and quantify the error associated with omitting time-dependent material effects, as is the case for all other TFM formulations. We anticipate that the 3D VTFM technique will open up new avenues of cell-material investigations on even more physiologically relevant time-dependent materials including collagen and fibrin gels. PMID:25170569

  2. Novel characteristics of traction force in biliary self-expandable metallic stents.

    PubMed

    Hori, Yasuki; Hayashi, Kazuki; Yoshida, Michihiro; Naitoh, Itaru; Ban, Tesshin; Miyabe, Katsuyuki; Kondo, Hiromu; Nishi, Yuji; Umemura, Shuichiro; Fujita, Yasuaki; Natsume, Makoto; Kato, Akihisa; Ohara, Hirotaka; Joh, Takashi

    2017-05-01

    In recent years, knowledge concerning the mechanical properties of self-expandable metallic stents (SEMS) has increased. In a previous study, we defined traction force and traction momentum and reported that these characteristics are important for optimal stent deployment. However, traction force and traction momentum were represented as relative values and were not evaluated in various conditions. The purpose of the present study was to measure traction force in various situations assumed during SEMS placement. Traction force and traction momentum were measured in non-stricture, stricture, and angled stricture models using in-house equipment. Stricture and angled stricture models had significantly higher traction force and traction momentum than those of the non-stricture model (stricture vs non-stricture: traction force, 7.2 N vs 1.4 N, P < 0.001; traction momentum, 237.8 Ns vs 62.3 Ns, P = 0.001; angled stricture vs non-stricture: traction force, 7.4 N vs 1.4 N, P < 0.001; traction momentum, 307.2 Ns vs 62.3 Ns, P < 0.001). Traction force was variable during SEMS placement and was categorized into five different stages, which were similar in both the stricture and angled stricture models. We measured traction force and traction momentum under simulated clinical conditions and demonstrated that strictures and the angular positioning of the stent influenced the traction force. Clinicians should be aware of the transition of the traction force and should schedule X-ray imaging during SEMS placement. © 2017 Japan Gastroenterological Endoscopy Society.

  3. Traction in smooth muscle cells varies with cell spreading

    NASA Technical Reports Server (NTRS)

    Tolic-Norrelykke, Iva Marija; Wang, Ning

    2005-01-01

    Changes in cell shape regulate cell growth, differentiation, and apoptosis. It has been suggested that the regulation of cell function by the cell shape is a result of the tension in the cytoskeleton and the distortion of the cell. Here we explore the association between cell-generated mechanical forces and the cell morphology. We hypothesized that the cell contractile force is associated with the degree of cell spreading, in particular with the cell length. We measured traction fields of single human airway smooth muscle cells plated on a polyacrylamide gel, in which fluorescent microbeads were embedded to serve as markers of gel deformation. The traction exerted by the cells at the cell-substrate interface was determined from the measured deformation of the gel. The traction was measured before and after treatment with the contractile agonist histamine, or the relaxing agonist isoproterenol. The relative increase in traction induced by histamine was negatively correlated with the baseline traction. On the contrary, the relative decrease in traction due to isoproterenol was independent of the baseline traction, but it was associated with cell shape: traction decreased more in elongated than in round cells. Maximum cell width, mean cell width, and projected area of the cell were the parameters most tightly coupled to both baseline and histamine-induced traction in this study. Wide and well-spread cells exerted larger traction than slim cells. These results suggest that cell contractility is controlled by cell spreading.

  4. Elastohydrodynamic Traction Properties of Seed Oils

    USDA-ARS?s Scientific Manuscript database

    The elastohydrodynamic traction coefficient (tc) properties of nine seed oils of varying chemical structures, PAO and hexadecane, were investigated using a ball-on disk traction apparatus. The seed oils were: castor oil, a triglyceride with hydroxyl functional group; jojoba, a monoglyceride; and s...

  5. Simplified fatigue life analysis for traction drive contacts

    NASA Technical Reports Server (NTRS)

    Rohn, D. A.; Loewenthal, S. H.; Coy, J. J.

    1980-01-01

    A simplified fatigue life analysis for traction drive contacts of arbitrary geometry is presented. The analysis is based on the Lundberg-Palmgren theory used for rolling-element bearings. The effects of torque, element size, speed, contact ellipse ratio, and the influence of traction coefficient are shown. The analysis shows that within the limits of the available traction coefficient, traction contacts exhibit longest life at high speeds. Multiple, load-sharing roller arrangements have an advantageous effect on system life, torque capacity, power-to-weight ratio and size.

  6. 21 CFR 882.5960 - Skull tongs for traction.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skull tongs for traction. 882.5960 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5960 Skull tongs for traction. (a) Identification. Skull tongs for traction is an instrument used to immobilize a patient with a...

  7. Advanced dc-Traction-Motor Control System

    NASA Technical Reports Server (NTRS)

    Vittone, O.

    1985-01-01

    Motor-control concept for battery-powered vehicles includes stateof-the-art power-transistor switching and separate excitation of motor windings in traction and regenerative braking. Switching transistors and other components of power-conditioning subsystem operate under control of computer that coordinates traction, braking, and protective functions.

  8. Traction for low-back pain with or without sciatica.

    PubMed

    Wegner, Inge; Widyahening, Indah S; van Tulder, Maurits W; Blomberg, Stefan E I; de Vet, Henrica Cw; Brønfort, Gert; Bouter, Lex M; van der Heijden, Geert J

    2013-08-19

    Traction has been used to treat low-back pain (LBP), often in combination with other treatments. We included both manual and machine-delivered traction in this review. This is an update of a Cochrane review first published in 1995, and previously updated in 2006. To assess the effects of traction compared to placebo, sham traction, reference treatments and no treatment in people with LBP. We searched the Cochrane Back Review Group Specialized Register, the Cochrane Central Register of Controlled Trials (2012, Issue 8), MEDLINE (January 2006 to August 2012), EMBASE (January 2006 to August 2012), CINAHL (January 2006 to August 2012), and reference lists of articles and personal files. The review authors are not aware of any important new randomized controlled trial (RCTs) on this topic since the date of the last search. RCTs involving traction to treat acute (less than four weeks' duration), subacute (four to 12 weeks' duration) or chronic (more than 12 weeks' duration) non-specific LBP with or without sciatica. Two review authors independently performed study selection, risk of bias assessment and data extraction. As there were insufficient data for statistical pooling, we performed a descriptive analysis. We did not find any case series that identified adverse effects, therefore we evaluated adverse effects that were reported in the included studies. We included 32 RCTs involving 2762 participants in this review. We considered 16 trials, representing 57% of all participants, to have a low risk of bias based on the Cochrane Back Review Group's 'Risk of bias' tool.For people with mixed symptom patterns (acute, subacute and chronic LBP with and without sciatica), there was low- to moderate-quality evidence that traction may make little or no difference in pain intensity, functional status, global improvement or return to work when compared to placebo, sham traction or no treatment. Similarly, when comparing the combination of physiotherapy plus traction with

  9. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  10. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  11. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  12. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  13. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  14. Home Cervical Traction to Reduce Neck Pain in Fighter Pilots.

    PubMed

    Chumbley, Eric M; O'Hair, Nicole; Stolfi, Adrienne; Lienesch, Christopher; McEachen, James C; Wright, Bruce A

    2016-12-01

    Most fighter pilots report cervical pain during their careers. Recommendations for remediation lack evidence. We sought to determine whether regular use of a home cervical traction device could decrease reported cervical pain in F-15C pilots. An institutional review board-approved, Health Insurance Portability and Accountability Act-compliant, controlled crossover study was undertaken with 21 male F-15C fighter pilots between February and June 2015. Of the 21 subjects, 12 completed 6 wk each of traction and control, while logging morning, postflying, and post-traction pain. Pain was compared with paired t-tests between the periods, from initial pain scores to postflying, and postflying to post-traction. In the traction phase, initial pain levels increased postflight, from 1.2 (0.7) to 1.6 (1.0) Subsequent post-traction pain levels decreased to 1.3 (0.9), with a corresponding linear decrease in pain relative to pain reported postflight. The difference in pain levels after traction compared to initial levels was not significant, indicating that cervical traction was effective in alleviating flying-related pain. Control pain increased postflight from 1.4 (0.9) to 1.9 (1.3). Daily traction phase pain was lower than the control, but insignificant. To our knowledge, this is the first study of home cervical traction to address fighter pilots' cervical pain. We found a small but meaningful improvement in daily pain rating when using cervical traction after flying. These results help inform countermeasure development for pilots flying high-performance aircraft. Further study should clarify the optimal traction dose and timing in relation to flying.Chumbley EM, O'Hair N, Stolfi A, Lienesch C, McEachen JC, Wright BA. Home cervical traction to reduce neck pain in fighter pilots. Aerosp Med Hum Perform. 2016; 87(12):1010-1015.

  15. Pins and Rubbers Traction System.

    PubMed

    de Soras, X; de Mourgues, P; Guinard, D; Moutet, F

    1997-12-01

    The Pins and Rubbers Traction System (PRTS) is a mobile frame created with wires to support elastic traction, which produces a ligamentotaxis effect in the same direction and of the same intensity whatever the position of the joint. This technique has been used in 11 cases of complex PIP joint fractures with eight excellent results. The advantages are simplicity, adaptability, the possibility of immediate mobilization, reasonable cost and relatively small bulk.

  16. Lateral traction

    MedlinePlus

    ... treat or reduce any joint dislocation or bone fracture by applying tension to the leg or arm with weights and pulleys to realign the bone. For example, it may be used to help line up a broken bone while it heals. Traction as a treatment involves the amount of ...

  17. Beyond game effectiveness. Part II, a qualitative study of multi-role experiential learning.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, Matthew; Tucker, Eilish Marie; Raybourn, Elaine Marie

    The present paper is the second in a series published at I/ITSEC that seeks to explain the efficacy of multirole experiential learning employed to create engaging game-based training methods transitioned to the U.S. Army, U.S. Army Special Forces, Civil Affairs, and Psychological Operations teams. The first publication (I/ITSEC 2009) summarized findings from a quantitative study that investigated experiential learning in the multi-player, PC-based game module transitioned to PEO-STRI, DARWARS Ambush! NK (non-kinetic). The 2009 publication reported that participants of multi-role (Player and Reflective Observer/Evaluator) game-based training reported statistically significant learning and engagement. Additionally when the means of the two groupsmore » (Player and Reflective Observer/Evaluator) were compared, they were not statistically significantly different from each other. That is to say that both playing as well as observing/evaluating were engaging learning modalities. The Observer/Evaluator role was designed to provide an opportunity for real-time reflection and meta-cognitive learning during game play. Results indicated that this role was an engaging way to learn about communication, that participants learned something about cultural awareness, and that the skills they learned were helpful in problem solving and decision-making. The present paper seeks to continue to understand what and how users of non-kinetic game-based missions learn by revisiting the 2009 quantitative study with further investigation such as stochastic player performance analysis using latent semantic analyses and graph visualizations to correlate against human coder ratings and pre- and post-test self-analysis. The results are applicable to First-Person game-based learning systems designed to enhance trainee intercultural communication, interpersonal skills, and adaptive thinking. In the full paper, we discuss results obtained from data collected from 78 research participants of

  18. Elastohydrodynamic (EHD) traction properties of seed oils

    USDA-ARS?s Scientific Manuscript database

    The elastohydrodynamic traction coefficient (tc) properties of nine seed oils of varying chemical structures, PAO and hexadecane, were investigated using a ball-on disk traction apparatus. The seed oils were: castor oil, a triglyceride with hydroxyl functional group; jojoba, a monoglyceride; and sev...

  19. Rectus femoris muscle atrophy and recovery caused by preoperative pretibial traction in femoral shaft fractures-comparison between traction period.

    PubMed

    Shim, D-G; Kwon, T-Y; Lee, K-B

    2017-09-01

    Skeletal traction is performed to temporarily stabilize fracture sites before surgery in patients with femoral fracture. To date, however, there is no study evaluating the difference in the degree of the recovery, of the muscle strength, as well as muscle atrophy following skeletal traction. The purpose of this study was to compare the degree of recovery of rectus femoris muscle strength after surgery in association with muscle atrophy by analyzing the duration of preoperative tibial traction, age and sex in patients with femoral fracture. Rectus femoris muscle atrophy will progress depending on the duration of preoperative tibial traction, age and sex in patients with femoral fracture. Thirty-one patients who underwent preoperative pretibial skeletal traction and intramedullary nailing were divided into two groups according to the traction period: group A (n=12) with a duration of traction of <7 days (mean: 4.08±1.78 days) and group B (n=19) ≥7 days (mean: 13.63±7.17 days). The degree of muscle atrophy and recovery were compared between the two groups, according to age and gender. The degree of muscle atrophy was measured by the difference in thickness of the rectus femoris between pre- and post-traction using ultrasound. The degree of muscle recovery was evaluated by the Q-setting and heel off time. Clinical outcome was evaluated by the non-union rate and Lysholm score. The degree of muscle atrophy was 0.99±0.14mm in group A and 2.22±0.11mm in group B (P<0.001). The Q-setting time was 4.83±0.94 days in group A and 6.56±1.38 days in group B (P=0.001). Heel off time was also shorter in group A at 2.58±0.90 days, taking 3.72±1.27 days in group B (P=0.012). The recovery rate in the rectus femoris was significantly higher in group A than in group B (P<0.001). There was no significant difference in non-union rate between group A and B (P=0.672) but the mean Lysholm score at the last follow-up was significantly higher in group A than in group B (P=0

  20. 21 CFR 888.5890 - Noninvasive traction component.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Noninvasive traction component. 888.5890 Section 888.5890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5890 Noninvasive traction component. (a...

  1. 21 CFR 888.5890 - Noninvasive traction component.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Noninvasive traction component. 888.5890 Section 888.5890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5890 Noninvasive traction component. (a...

  2. 21 CFR 888.5890 - Noninvasive traction component.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Noninvasive traction component. 888.5890 Section 888.5890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5890 Noninvasive traction component. (a...

  3. 21 CFR 888.5890 - Noninvasive traction component.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Noninvasive traction component. 888.5890 Section 888.5890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5890 Noninvasive traction component. (a...

  4. 21 CFR 888.5890 - Noninvasive traction component.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Noninvasive traction component. 888.5890 Section 888.5890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5890 Noninvasive traction component. (a...

  5. Micropatterning tractional forces in living cells

    NASA Technical Reports Server (NTRS)

    Wang, Ning; Ostuni, Emanuele; Whitesides, George M.; Ingber, Donald E.

    2002-01-01

    Here we describe a method for quantifying traction in cells that are physically constrained within micron-sized adhesive islands of defined shape and size on the surface of flexible polyacrylamide gels that contain fluorescent microbeads (0.2-microm diameter). Smooth muscle cells were plated onto square (50 x 50 microm) or circular (25- or 50-microm diameter) adhesive islands that were created on the surface of the gels by applying a collagen coating through microengineered holes in an elastomeric membrane that was later removed. Adherent cells spread to take on the size and shape of the islands and cell tractions were quantitated by mapping displacement fields of the fluorescent microbeads within the gel. Cells on round islands did not exhibit any preferential direction of force application, but they exerted their strongest traction at sites where they formed protrusions. When cells were confined to squares, traction was highest in the corners both in the absence and presence of the contractile agonist, histamine, and cell protrusions were also observed in these regions. Quantitation of the mean traction exerted by cells cultured on the different islands revealed that cell tension increased as cell spreading was promoted. These results provide a mechanical basis for past studies that demonstrated a similar correlation between spreading and growth within various anchorage-dependent cells. This new approach for analyzing the spatial distribution of mechanical forces beneath individual cells that are experimentally constrained to defined sizes and shapes may provide additional insight into the biophysical basis of cell regulation. Copyright 2002 Wiley-Liss, Inc.

  6. Toward single cell traction microscopy within 3D collagen matrices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Matthew S.; Long, Rong; Feng, Xinzeng

    Mechanical interaction between the cell and its extracellular matrix (ECM) regulates cellular behaviors, including proliferation, differentiation, adhesion, and migration. Cells require the three-dimensional (3D) architectural support of the ECM to perform physiologically realistic functions. However, current understanding of cell–ECM and cell–cell mechanical interactions is largely derived from 2D cell traction force microscopy, in which cells are cultured on a flat substrate. 3D cell traction microscopy is emerging for mapping traction fields of single animal cells embedded in either synthetic or natively derived fibrous gels. We discuss here the development of 3D cell traction microscopy, its current limitations, and perspectives onmore » the future of this technology. Emphasis is placed on strategies for applying 3D cell traction microscopy to individual tumor cell migration within collagen gels. - Highlights: • Review of the current state of the art in 3D cell traction force microscopy. • Bulk and micro-characterization of remodelable fibrous collagen gels. • Strategies for performing 3D cell traction microscopy within collagen gels.« less

  7. Electric vehicle regenerative antiskid braking and traction control system

    DOEpatents

    Cikanek, S.R.

    1995-09-12

    An antiskid braking and traction control system for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes one or more sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensors and determining if regenerative antiskid braking control, requiring hydraulic braking control, or requiring traction control are required. The processor then employs a control strategy based on the determined vehicle state and provides command signals to a motor controller to control the operation of the electric traction motor and to a brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative antiskid braking control, hydraulic braking control, and traction control. 10 figs.

  8. Electric vehicle regenerative antiskid braking and traction control system

    DOEpatents

    Cikanek, Susan R.

    1995-01-01

    An antiskid braking and traction control system for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes one or more sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensors and determining if regenerative antiskid braking control, requiring hydrualic braking control, or requiring traction control are required. The processor then employs a control strategy based on the determined vehicle state and provides command signals to a motor controller to control the operation of the electric traction motor and to a brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative antiskid braking control, hydraulic braking control, and traction control.

  9. 21 CFR 890.5900 - Power traction equipment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Power traction equipment. 890.5900 Section 890.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5900 Power traction...

  10. 21 CFR 890.5900 - Power traction equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Power traction equipment. 890.5900 Section 890.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5900 Power traction...

  11. 21 CFR 890.5900 - Power traction equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Power traction equipment. 890.5900 Section 890.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5900 Power traction...

  12. 21 CFR 890.5900 - Power traction equipment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Power traction equipment. 890.5900 Section 890.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5900 Power traction...

  13. 21 CFR 890.5900 - Power traction equipment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Power traction equipment. 890.5900 Section 890.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5900 Power traction...

  14. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  15. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  16. Testing and evaluation of recovered traction sanding material.

    DOT National Transportation Integrated Search

    2013-04-01

    The Montana Department of Transportation (MDT) is searching for a solution to the accumulation of traction sand that is applied to Montana highways every winter. An analysis of reuse and recycle options for salvaged traction sand was conducted using ...

  17. Asymmetric vitreomacular traction and symmetrical full thickness macular hole formation.

    PubMed

    Woon, Wai H; Greig, Denis; Savage, Mike D; Wilson, Mark C T; Grant, Colin A; Bishop, Fiona; Mokete, Bataung

    2015-11-01

    A Full Thickness Macular Hole (FTMH) is often associated with vitreomacular traction, and this can be asymmetric with vitreomacular traction on one side of the hole but not the other. In cross-section, the elevated retinal rim around a developed FTMH is seen as a drawbridge elevation, and this drawbridge elevation may be used as a measure of morphological change. Examination of the drawbridge elevation of the retinal rim in FTMH with asymmetric vitreomacular traction may help to clarify the role of vitreomacular traction in the development of FTMH. Cases of FTMH were identified with an initial OCT scan showing vitreomacular traction on one side of the hole only and that had a follow-up OCT scan showing progression of the hole. A tangent to the retinal surface at a distance of 700 microns from the axis of the hole was used as a marker of the drawbridge elevation of the retinal rim around the macular hole. Comparisons of the drawbridge elevation and change in drawbridge elevation between the sides with and without initial vitreomacular traction were made. There was no significant difference between the drawbridge elevation, or change in drawbridge elevation, on the side of the hole with initial vitreomacular traction compared to the side without initial traction. There is some intrinsic mechanism within the retina to link the morphological changes on the two sides of a FTMH. A bistable hypothesis of FTMH formation and closure is postulated to explain this linkage.

  18. Comparison of the intervertebral disc spaces between axial and anterior lean cervical traction.

    PubMed

    Chung, Chin-Teng; Tsai, Sen-Wei; Chen, Chun-Jung; Wu, Ting-Chung; Wang, David; Lan, Haw-Chang H; Wu, Shyi-Kuen

    2009-11-01

    The insufficient investigations on the changes of spinal structures during traction prevent further exploring the possible therapeutic mechanism of cervical traction. A blind randomized crossover-design study was conducted to quantitatively compare the intervertebral disc spaces between axial and anterior lean cervical traction in sitting position. A total of 96 radiographic images from the baseline measurements, axial and anterior lean tractions in 32 asymptomatic subjects were digitized for further analysis. The intra- and inter-examiner reliabilities for measuring the intervertebral disc spaces were in good ranges (ICCs = 0.928-0.942). With the application of anterior lean traction, the statistical increases were detected both in anterior and in posterior disc spaces compared to the baseline (0.29 mm and 0.24 mm; both P < 0.01) and axial traction (0.16 mm and 0.35 mm; both P < 0.01). The greater intervertebral disc spaces obtained during anterior lean traction might be associated with the more even distribution of traction forces over the anterior and posterior neck structures. The neck extension moment through mandible that generally occurred in the axial traction could be counteracted by the downward force of head weight during anterior lean traction. This study quantitatively demonstrated that anterior lean traction in sitting position provided more intervertebral disc space enlargements in both anterior and posterior aspects than axial traction did. These findings may serve as a therapeutic reference when cervical traction is suggested.

  19. Traction Stresses Exerted by Adherent Cells: From Angiogenesis to Metastasis

    NASA Astrophysics Data System (ADS)

    Reinhart-King, Cynthia

    2010-03-01

    Cells exert traction stresses against their substrate that mediate their ability to sense the mechanical properties of their microenvironment. These same forces mediate cell adhesion, migration and the formation of stable cell-cell contacts during tissue formation. In this talk, I will present our data on the traction stresses generated by endothelial cells and metastatic breast cancer cells focused on understanding the processes of angiogenesis and metastasis, respectively. In the context of capillary formation, our data indicate that the mechanics of the substrate play a critical role in establishing endothelial cell-cell contacts. On more compliant substrates, endothelial cell shape and traction stresses polarize and promote the formation of stable cell-cell contacts. On stiffer substrates, traction stresses are less polarized and cell connectivity is disrupted. These data indicate that the mechanical properties of the microenvironment may drive cell connectivity and the formation of stable cell-cell contacts through the reorientation of traction stresses. In our studies of metastatic cell migration, we have found that traction stresses increase with increasing metastatic potential. We investigated three lines of varying metastatic potential (MCF10A, MCF7 and MDAMB231). MDAMB231, which are the most invasive, exert the most significant forces as measured by Traction Force Microscopy. These data present the possibility that cellular traction stress generation aids in the ability of metastatic cells to migrate through the matrix-dense tumor microenvironment. Such measurements are integral to link the mechanical and chemical microenvironment with the resulting response of the cell in health and disease.

  20. Traction test of temporary dental cements.

    PubMed

    Román-Rodríguez, Juan-Luis; Millan-Martínez, Diego; Fons-Font, Antonio; Agustín-Panadero, Rubén; Fernández-Estevan, Lucía

    2017-04-01

    Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear (TBC) and Telio CS link (TE). Each sample underwent traction testing, both with thermocycling (190 cycles at 5-55º) and without thermocycling. TE and TBC obtained the highest traction resistance values. Thermocycling reduced the resistance of all cements except TBC. The dual-cure esthetic cements tested provided optimum outcomes for bonding provisional restorations. Key words: Temporary dental cements, cements resistance.

  1. Traction force dynamics predict gap formation in activated endothelium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valent, Erik T.; Nieuw Amerongen, Geerten P. van; Hinsbergh, Victor W.M. van

    In many pathological conditions the endothelium becomes activated and dysfunctional, resulting in hyperpermeability and plasma leakage. No specific therapies are available yet to control endothelial barrier function, which is regulated by inter-endothelial junctions and the generation of acto-myosin-based contractile forces in the context of cell-cell and cell-matrix interactions. However, the spatiotemporal distribution and stimulus-induced reorganization of these integral forces remain largely unknown. Traction force microscopy of human endothelial monolayers was used to visualize contractile forces in resting cells and during thrombin-induced hyperpermeability. Simultaneously, information about endothelial monolayer integrity, adherens junctions and cytoskeletal proteins (F-actin) were captured. This revealed a heterogeneousmore » distribution of traction forces, with nuclear areas showing lower and cell-cell junctions higher traction forces than the whole-monolayer average. Moreover, junctional forces were asymmetrically distributed among neighboring cells. Force vector orientation analysis showed a good correlation with the alignment of F-actin and revealed contractile forces in newly formed filopodia and lamellipodia-like protrusions within the monolayer. Finally, unstable areas, showing high force fluctuations within the monolayer were prone to form inter-endothelial gaps upon stimulation with thrombin. To conclude, contractile traction forces are heterogeneously distributed within endothelial monolayers and force instability, rather than force magnitude, predicts the stimulus-induced formation of intercellular gaps. - Highlights: • Endothelial monolayers exert dynamic- and heterogeneous traction forces. • High traction forces correlate with junctional areas and the F-actin cytoskeleton. • Newly formed inter-endothelial gaps are characterized by opposing traction forces. • Force stability is a key feature controlling endothelial permeability.« less

  2. The effect of cavernous nerve traction on erectile function in rats

    PubMed Central

    Chen, Liping; Wang, Tao; Wang, Shaogang; Liu, Jihong

    2017-01-01

    We performed this study to evaluate the effect of cavernous nerve (CN) traction on erectile function in rats. Thirty-two 8- week-old Sprague–Dawley rats were divided into four groups: control, 1-minute CN traction, 2-minute CN traction, and 2-minute CN crush. CN traction was performed using a glass hook with a tensile force of 0.2 Newton. One month later, the mean arterial pressure (MAP) and intracavernosal pressure (ICP) in response to CN stimulation were measured to assess erectile function. The penis and major pelvic ganglion (MPG) were harvested to explore the expression of neuronal nitric oxide synthase (nNOS) and neurofilament, fibrosis and apoptosis. The ICP/MAP ratio was reduced in the 2-minute CN traction group compared with the control group (P < 0.05). The ICP/MAP ratio in the CN crush group was lower than in the other three groups (P < 0.05, for each). Expression of nNOS in both MPG and dorsal penile nerve was lower in the CN traction group than in the control group, but was higher than in the CN crush group (P < 0.05). Nerve fiber number in the dorsal penile nerve was reduced by 2-minute CN traction (P < 0.05). The ratios of collagen to smooth muscle content and the apoptosis were both increased the in 2-minute CN traction group compared with the control group (P < 0.05). The findings indicate that CN traction is an effective CN injury model and the injury it caused is relatively mild compared with the CN crush model. PMID:28982169

  3. Integral Sensor Fault Detection and Isolation for Railway Traction Drive.

    PubMed

    Garramiola, Fernando; Del Olmo, Jon; Poza, Javier; Madina, Patxi; Almandoz, Gaizka

    2018-05-13

    Due to the increasing importance of reliability and availability of electric traction drives in Railway applications, early detection of faults has become an important key for Railway traction drive manufacturers. Sensor faults are important sources of failures. Among the different fault diagnosis approaches, in this article an integral diagnosis strategy for sensors in traction drives is presented. Such strategy is composed of an observer-based approach for direct current (DC)-link voltage and catenary current sensors, a frequency analysis approach for motor current phase sensors and a hardware redundancy solution for speed sensors. None of them requires any hardware change requirement in the actual traction drive. All the fault detection and isolation approaches have been validated in a Hardware-in-the-loop platform comprising a Real Time Simulator and a commercial Traction Control Unit for a tram. In comparison to safety-critical systems in Aerospace applications, Railway applications do not need instantaneous detection, and the diagnosis is validated in a short time period for reliable decision. Combining the different approaches and existing hardware redundancy, an integral fault diagnosis solution is provided, to detect and isolate faults in all the sensors installed in the traction drive.

  4. Integral Sensor Fault Detection and Isolation for Railway Traction Drive

    PubMed Central

    del Olmo, Jon; Poza, Javier; Madina, Patxi; Almandoz, Gaizka

    2018-01-01

    Due to the increasing importance of reliability and availability of electric traction drives in Railway applications, early detection of faults has become an important key for Railway traction drive manufacturers. Sensor faults are important sources of failures. Among the different fault diagnosis approaches, in this article an integral diagnosis strategy for sensors in traction drives is presented. Such strategy is composed of an observer-based approach for direct current (DC)-link voltage and catenary current sensors, a frequency analysis approach for motor current phase sensors and a hardware redundancy solution for speed sensors. None of them requires any hardware change requirement in the actual traction drive. All the fault detection and isolation approaches have been validated in a Hardware-in-the-loop platform comprising a Real Time Simulator and a commercial Traction Control Unit for a tram. In comparison to safety-critical systems in Aerospace applications, Railway applications do not need instantaneous detection, and the diagnosis is validated in a short time period for reliable decision. Combining the different approaches and existing hardware redundancy, an integral fault diagnosis solution is provided, to detect and isolate faults in all the sensors installed in the traction drive. PMID:29757251

  5. Investigation of re-use options for used traction sand.

    DOT National Transportation Integrated Search

    2010-06-01

    The Colorado Department of Transportation (CDOT) uses approximately 24,000 tons of traction sand annually, : especially in mountain locations. Once traction sand is applied, street sweepers reclaim approximately 50% of the : sand, which is either sto...

  6. Rolling-element fatigue life with two synthetic cycloaliphatic traction fluids

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Parker, R. J.

    1976-01-01

    The life potential of two synthetic cycloaliphatic hydrocarbon traction fluids in rolling element fatigue was evaluated in a five ball fatigue tester. Life comparisons with a MIL-L-23699 qualified tetraester oil showed that the traction test oils had good fatigue life performance, comparable to that of the tetraester oil. No statistically significant life differences between the traction fluids and the tetraester oil were exhibited under the accelerated fatigue test conditions. Erratic operating behavior was occasionally encountered during tests with the antiwear additive containing traction fluid for reasons thought to be related to excessive chemical activity under high contact pressure. This behavior occasionally resulted in premature test termination due to excessive surface distress and overheating.

  7. Measuring traction forces of motile dendritic cells on micropost arrays.

    PubMed

    Ricart, Brendon G; Yang, Michael T; Hunter, Christopher A; Chen, Christopher S; Hammer, Daniel A

    2011-12-07

    Dendritic cells (DCs) migrate from sites of inflammation to secondary lymphoid organs where they initiate the adaptive immune response. Although motility is essential to DC function, the mechanisms by which they migrate are not fully understood. We incorporated micropost array detectors into a microfluidic gradient generator to develop what we consider to be a novel method for probing low magnitude traction forces during directional migration. We found migration of primary murine DCs is driven by short-lived traction stresses at the leading edge or filopodia. The traction forces generated by DCs are smaller in magnitude than found in neutrophils, and of similar magnitude during chemotaxis and chemokinesis, at 18 ± 1.4 and 16 ± 1.3 nN/cell, respectively. The characteristic duration of local DC traction forces was 3 min. The maximum principal stress in the cell occurred in the plane perpendicular to the axis of motion, forward of the centroid. We illustrate that the spatiotemporal pattern of traction stresses can be used to predict the direction of future DC motion. Overall, DCs show a mode of migration distinct from both mesenchymal cells and neutrophils, characterized by rapid turnover of traction forces in leading filopodia. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  8. Fuzzy logic electric vehicle regenerative antiskid braking and traction control system

    DOEpatents

    Cikanek, Susan R.

    1994-01-01

    An regenerative antiskid braking and traction control system using fuzzy logic for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensor and determining if regenerative antiskid braking control, requiring hydraulic braking control, and requiring traction control are required. The processor then employs fuzzy logic based on the determined vehicle state and provides command signals to a motor controller to control operation of the electric traction motor and to the brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative braking control, hydraulic braking control, and traction control.

  9. Traction test of temporary dental cements

    PubMed Central

    Millan-Martínez, Diego; Fons-Font, Antonio; Agustín-Panadero, Rubén; Fernández-Estevan, Lucía

    2017-01-01

    Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and Methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear (TBC) and Telio CS link (TE). Each sample underwent traction testing, both with thermocycling (190 cycles at 5-55º) and without thermocycling. Results TE and TBC obtained the highest traction resistance values. Thermocycling reduced the resistance of all cements except TBC. Conclusions The dual-cure esthetic cements tested provided optimum outcomes for bonding provisional restorations. Key words:Temporary dental cements, cements resistance. PMID:28469824

  10. Electric Transport Traction Power Supply System With Distributed Energy Sources

    NASA Astrophysics Data System (ADS)

    Abramov, E. Y.; Schurov, N. I.; Rozhkova, M. V.

    2016-04-01

    The paper states the problem of traction substation (TSS) leveling of daily-load curve for urban electric transport. The circuit of traction power supply system (TPSS) with distributed autonomous energy source (AES) based on photovoltaic (PV) and energy storage (ES) units is submitted here. The distribution algorithm of power flow for the daily traction load curve leveling is also introduced in this paper. In addition, it illustrates the implemented experiment model of power supply system.

  11. Fuzzy logic electric vehicle regenerative antiskid braking and traction control system

    DOEpatents

    Cikanek, S.R.

    1994-10-25

    An regenerative antiskid braking and traction control system using fuzzy logic for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensor and determining if regenerative antiskid braking control, requiring hydraulic braking control, and requiring traction control are required. The processor then employs fuzzy logic based on the determined vehicle state and provides command signals to a motor controller to control operation of the electric traction motor and to the brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative braking control, hydraulic braking control, and traction control. 123 figs.

  12. Spatial and temporal traction response in human airway smooth muscle cells

    NASA Technical Reports Server (NTRS)

    Tolic-Norrelykke, Iva Marija; Butler, James P.; Chen, Jianxin; Wang, Ning

    2002-01-01

    Tractions that cells exert on their substrates are essential in cell spreading, migration, and contraction. These tractions can be determined by plating the cells on a flexible gel and measuring the deformation of the gel by using fluorescent beads embedded just below the surface of the gel. In this article we describe the image correlation method (ICM) optimized for determining the displacement field of the gel under a contracting cell. For the calculation of the traction field from the displacement field we use the recently developed method of Fourier transform traction cytometry (FTTC). The ICM and FTTC methods are applied to human airway smooth muscle cells during stimulation with the contractile agonist histamine or the relaxing agonist isoproterenol. The overall intensity of the cell contraction (the median traction magnitude, the energy transferred from the cell to the gel, and the net contractile moment) increased after activation with histamine, and decreased after treatment with isoproterenol. Cells exhibited regional differences in the time course of traction during the treatment. Both temporal evolution and magnitude of traction increase induced by histamine varied markedly among different cell protrusions, whereas the nuclear region showed the smallest response. These results suggest that intracellular mediators of cell adhesion and contraction respond to contractile stimuli with different rates and intensities in different regions of the cell.

  13. Traction and film thickness measurements under starved elastohydrodynamic conditions

    NASA Technical Reports Server (NTRS)

    Wedeven, L. D.

    1974-01-01

    Traction measurements under starved elastohydrodynamic conditions were obtained for a point contact geometry. Simultaneous measurements of the film thickness and the locations of the inlet lubricant boundary were made optically. The thickness of a starved film for combination rolling and sliding conditions varies with the location of the inlet boundary in the same way found previously for pure rolling. A starved film was observed to possess greater traction than a flooded film for the same slide roll ratio. For a given slide roll ratio a starved film simply increases the shear rate in the Hertz region. The maximum shear rate depends on the degree of starvation and has no theoretical limit. Traction measurements under starved conditions were compared with flooded conditions under equivalent shear rates in the Hertz region. When the shear rates in the Hertz region were low and the film severely starved, the measured tractions were found to be much lower than expected.

  14. Scoliosis elasticity assessed by manual traction: 49 juvenile and adolescent idiopathic cases.

    PubMed

    Soucacos, P K; Soucacos, P N; Beris, A E

    1996-04-01

    We assessed preoperative curve elasticity in 49 consecutive patients with juvenile or adolescent idiopathic scoliosis who were operated on with Harrington distraction rods. Preoperatively, the curve was determined from posteroanterior radiographs taken in the standing position and in the supine position, with traction. In the latter, the radiographs were taken at the moment of maximal traction when one technician applied traction to the ankles and another to the wrists. The scoliotic curve in the 10 patients with juvenile scoliosis averaged 59 degrees and 32 degrees in the standing and supine positions with traction, respectively. Immediately postoperatively, the curve averaged 19 degrees. 39 patients with adolescent scoliosis had a scoliotic curve which averaged 58 degrees in the standing position and 32 degrees in the supine position with traction. The mean postoperative measurement was 21 degrees. These findings suggest that manual traction is a simple and reliable means of predicting the minimal correction of the scoliotic curve to be expected, using Harrington distraction rods.

  15. Multiroller Traction Drive Speed Reducer. Evaluation for Automotive Gas Turbine Engine

    DTIC Science & Technology

    1982-06-01

    Speed is deLermined by a magnetic pickup on a toothed wheel . Gas turbine engine instrumunelLtiouu i -designed 1f0r measurement of specific fuel...buffer seal and the fluid--film bearing measured a maximum total runout of 0.038 mm (0.0015 in.) at low speed. At higher speeds, above 8000 rpm, the...maximum was 0.025 mm (0.001 in.) except near 10 000 rpm, where the oscilloscope indicated an excursion of 0.045 mm (0.0018 in.). This runout was within

  16. Traction cytometry: regularization in the Fourier approach and comparisons with finite element method.

    PubMed

    Kulkarni, Ankur H; Ghosh, Prasenjit; Seetharaman, Ashwin; Kondaiah, Paturu; Gundiah, Namrata

    2018-05-09

    Traction forces exerted by adherent cells are quantified using displacements of embedded markers on polyacrylamide substrates due to cell contractility. Fourier Transform Traction Cytometry (FTTC) is widely used to calculate tractions but has inherent limitations due to errors in the displacement fields; these are mitigated through a regularization parameter (γ) in the Reg-FTTC method. An alternate finite element (FE) approach computes tractions on a domain using known boundary conditions. Robust verification and recovery studies are lacking but essential in assessing the accuracy and noise sensitivity of the traction solutions from the different methods. We implemented the L2 regularization method and defined a maximum curvature point in the traction with γ plot as the optimal regularization parameter (γ*) in the Reg-FTTC approach. Traction reconstructions using γ* yield accurate values of low and maximum tractions (Tmax) in the presence of up to 5% noise. Reg-FTTC is hence a clear improvement over the FTTC method but is inadequate to reconstruct low stresses such as those at nascent focal adhesions. FE, implemented using a node-by-node comparison, showed an intermediate reconstruction compared to Reg-FTTC. We performed experiments using mouse embryonic fibroblast (MEF) and compared results between these approaches. Tractions from FTTC and FE showed differences of ∼92% and 22% as compared to Reg-FTTC. Selection of an optimum value of γ for each cell reduced variability in the computed tractions as compared to using a single value of γ for all the MEF cells in this study.

  17. Targeted traction of impacted teeth with C-tube miniplates.

    PubMed

    Chung, Kyu-Rhim; Kim, Yong; Ahn, Hyo-Won; Lee, Dongjoo; Yang, Dong-Min; Kim, Seong-Hun; Nelson, Gerald

    2014-09-01

    Orthodontic traction of impacted teeth has typically been performed using full fixed appliance as anchorage against the traction force. This conventional approach can be difficult to apply in the mixed dentition if the partial fixed appliance offers an insufficient anchor unit. In addition, full fixed appliance can induce unwanted movement of adjacent teeth. This clinical report presents 3 cases where impacted teeth were recovered in the mixed or transitional dentition with skeletal anchorage on the opposite arch without full fixed appliance. Instead, intermaxillary traction was used to bring the impacted teeth into position. With this approach, side effects on teeth and periodontal tissues adjacent to the impaction were minimized.

  18. [Research on the stability of teaching robots of rotation-traction manipulation].

    PubMed

    Feng, Min-Shan; Zhu, Li-Guo; Wang, Shang-Quan; Yu, Jie; Chen, Ming; Li, Ling-Hui; Wei, Xu

    2017-03-25

    To evaluate the stability of teaching robot of rotation-traction manipulation. Operators were required to get the hang of rotation-traction manipulation and had clinical experience for over 5 years. The examination and data processing of the ten operators in our research were collected by the teaching robot of rotation-traction manipulation. Traction, pulling force, maximum force, pulling time, rotational amplitude and pitch range were recorded and compared for five times(G1, G2, G3, G4 and G5). The qualification rates were analyzed to evaluate the stability of teaching robot of rotation-traction manipulation. Nonconforming items were found in G1 and G2, for instance, pulling force( P =0.074), maximum force( P =0.264) and rotational amplitude ( P =0.531). There was no statistically difference. None nonconforming item was found in G3, G4 and G5. All data were processed by SPSS and One-way ANOVA was used to analysis. Pulling force was found statistically different in G1, compared with G4 and G5( P =0.015, P =0.006). Maximum force was found statistically different in G1, compared with G4 and G5 ( P =0.021, P =0.012). None differences were found in other comparisons ( P >0.05). The teaching robot of rotation-traction manipulation used in our research could provide objective and quantitative indices and was considered to be an effective tool of assessing the rotation-traction manipulation.

  19. Traction sheave elevator, hoisting unit and machine space

    DOEpatents

    Hakala, Harri; Mustalahti, Jorma; Aulanko, Esko

    2000-01-01

    Traction sheave elevator consisting of an elevator car moving along elevator guide rails, a counterweight moving along counterweight guide rails, a set of hoisting ropes (3) on which the elevator car and counterweight are suspended, and a drive machine unit (6) driving a traction sheave (7) acting on the hoisting ropes (3) and placed in the elevator shaft. The drive machine unit (6) is of a flat construction. A wall of the elevator shaft is provided with a machine space with its open side facing towards the shaft, the essential parts of the drive machine unit (6) being placed in the space. The hoisting unit (9) of the traction sheave elevator consists of a substantially discoidal drive machine unit (6) and an instrument panel (8) mounted on the frame (20) of the hoisting unit.

  20. Friction self-oscillation decrease in nonlinear system of locomotive traction drive

    NASA Astrophysics Data System (ADS)

    Antipin, D. Ya; Vorobiyov, V. I.; Izmerov, O. V.; Shorokhov, S. G.; Bondarenko, D. A.

    2017-02-01

    The problems of the friction self-oscillation decrease in a nonlinear system of a locomotive traction drive are considered. It is determined that the self-oscillation amplitude decrease in a locomotive wheel pair during boxing in traction drives with an elastic linkage between an armature of a traction electric motor and gearing can be achieved due to drive damping capacity during impact vibro-damping in an axle reduction gear with a hard driven gear. The self-oscillation amplitude reduction in a wheel pair in the designs of locomotive traction drives with the location of elastic elements between a wheel pair and gearing can be obtained owing to the application of drive inertial masses as an anti-vibrator. On the basis of the carried out investigations, a design variant of a self-oscillation shock absorber of a traction electric motor framework on a reduction gear suspension with an absorber located beyond a wheel-motor unit was offered.

  1. Tractional retinal detachment in Usher syndrome type II.

    PubMed

    Rani, Alka; Pal, Nikhil; Azad, Raj Vardhan; Sharma, Yog Raj; Chandra, Parijat; Vikram Singh, Deependra

    2005-08-01

    Retinal detachment is a rare complication in patients with retinitis pigmentosa. A case is reported of tractional retinal detachment in a patient with retinitis pigmentosa and sensorineural hearing loss, which was diagnosed as Usher syndrome type II. Because of the poor visual prognosis, the patient refused surgery in that eye. Tractional retinal detachment should be added to the differential diagnoses of visual loss in patients with retinitis pigmentosa.

  2. Microfabricated tissues for investigating traction forces involved in cell migration and tissue morphogenesis

    PubMed Central

    Nerger, Bryan A.; Siedlik, Michael J.; Nelson, Celeste M.

    2016-01-01

    Cell-generated forces drive an array of biological processes ranging from wound healing to tumor metastasis. Whereas experimental techniques such as traction force microscopy are capable of quantifying traction forces in multidimensional systems, the physical mechanisms by which these forces induce changes in tissue form remain to be elucidated. Understanding these mechanisms will ultimately require techniques that are capable of quantifying traction forces with high precision and accuracy in vivo or in systems that recapitulate in vivo conditions, such as microfabricated tissues and engineered substrata. To that end, here we review the fundamentals of traction forces, their quantification, and the use of microfabricated tissues designed to study these forces during cell migration and tissue morphogenesis. We emphasize the differences between traction forces in two- and three-dimensional systems, and highlight recently developed techniques for quantifying traction forces. PMID:28008471

  3. Prediction of traction forces of motile cells.

    PubMed

    Roux, Clément; Duperray, Alain; Laurent, Valérie M; Michel, Richard; Peschetola, Valentina; Verdier, Claude; Étienne, Jocelyn

    2016-10-06

    When crawling on a flat substrate, living cells exert forces on it via adhesive contacts, enabling them to build up tension within their cytoskeleton and to change shape. The measurement of these forces has been made possible by traction force microscopy (TFM), a technique which has allowed us to obtain time-resolved traction force maps during cell migration. This cell 'footprint' is, however, not sufficient to understand the details of the mechanics of migration, that is how cytoskeletal elements (respectively, adhesion complexes) are put under tension and reinforce or deform (respectively, mature and/or unbind) as a result. In a recent paper, we have validated a rheological model of actomyosin linking tension, deformation and myosin activity. Here, we complement this model with tentative models of the mechanics of adhesion and explore how closely these models can predict the traction forces that we recover from experimental measurements during cell migration. The resulting mathematical problem is a PDE set on the experimentally observed domain, which we solve using a finite-element approach. The four parameters of the model can then be adjusted by comparison with experimental results on a single frame of an experiment, and then used to test the predictive power of the model for following frames and other experiments. It is found that the basic pattern of traction forces is robustly predicted by the model and fixed parameters as a function of current geometry only.

  4. Rigid two-axis MEMS force plate for measuring cellular traction force

    NASA Astrophysics Data System (ADS)

    Takahashi, Hidetoshi; Jung, Uijin G.; Kan, Tetsuo; Tsukagoshi, Takuya; Matsumoto, Kiyoshi; Shimoyama, Isao

    2016-10-01

    Cellular traction force is one of the important factors for understanding cell behaviors, such as spreading, migration and differentiation. Cells are known to change their behavior according to the mechanical stiffness of the environment. However, the measurement of cell traction forces on a rigid environment has remained difficult. This paper reports a micro-electromechanical systems (MEMS) force plate that provides a cellular traction force measurement on a rigid substrate. Both the high force sensitivity and high stiffness of the substrate were obtained using piezoresistive sensing elements. The proposed force plate consists of a 70 µm  ×  15 µm  ×  5 µm base as the substrate for cultivating a bovine aortic smooth muscle cell, and the supporting beams with piezoresistors on the sidewall and the surface were used to measure the forces in both the horizontal and vertical directions. The spring constant and force resolution of the fabricated force plate in the horizontal direction were 0.2 N m-1 and less than 0.05 µN, respectively. The cell traction force was measured, and the traction force increased by approximately 1 µN over 30 min. These results demonstrate that the proposed force plate is applicable as an effective traction force measurement.

  5. Simplified and advanced modelling of traction control systems of heavy-haul locomotives

    NASA Astrophysics Data System (ADS)

    Spiryagin, Maksym; Wolfs, Peter; Szanto, Frank; Cole, Colin

    2015-05-01

    Improving tractive effort is a very complex task in locomotive design. It requires the development of not only mechanical systems but also power systems, traction machines and traction algorithms. At the initial design stage, traction algorithms can be verified by means of a simulation approach. A simple single wheelset simulation approach is not sufficient because all locomotive dynamics are not fully taken into consideration. Given that many traction control strategies exist, the best solution is to use more advanced approaches for such studies. This paper describes the modelling of a locomotive with a bogie traction control strategy based on a co-simulation approach in order to deliver more accurate results. The simplified and advanced modelling approaches of a locomotive electric power system are compared in this paper in order to answer a fundamental question. What level of modelling complexity is necessary for the investigation of the dynamic behaviours of a heavy-haul locomotive running under traction? The simulation results obtained provide some recommendations on simulation processes and the further implementation of advanced and simplified modelling approaches.

  6. Study on Stability of High Speed Traction Drive CVT for Aircraft Generator

    NASA Astrophysics Data System (ADS)

    Goi, Tatsuhiko; Tanaka, Hirohisa; Nakashima, Kenichi; Watanabe, Koji

    A half-toroidal traction drive CVT has a feature of small spin at traction pitch in whole speed ratio range of 1:4, which suits to transmit high rotational speed with minimum temperature increase of traction surface. Research activity on traction drive CVT has commenced in 1996 for applying it to an aircraft 24,000rpm constant-speed generator instead of a hydro-static transmission. This paper shows fundamental design of 90kW traction drive integrated drive generator, ``T-IDG", and stability analysis on a sensor-less electro-hydraulic speed control servo-mechanism by bond graphs. The performance test of T-IDG mounted on a test bench and an actual jet engine proved that the control system using sensor-less servomechanism can keep the generator speed within MIL-STD-704E allowable limit against steep changes of speed and load.

  7. Three-Dimensional Reflectance Traction Microscopy

    PubMed Central

    Jones, Christopher A. R.; Groves, Nicholas Scott; Sun, Bo

    2016-01-01

    Cells in three-dimensional (3D) environments exhibit very different biochemical and biophysical phenotypes compared to the behavior of cells in two-dimensional (2D) environments. As an important biomechanical measurement, 2D traction force microscopy can not be directly extended into 3D cases. In order to quantitatively characterize the contraction field, we have developed 3D reflectance traction microscopy which combines confocal reflection imaging and partial volume correlation postprocessing. We have measured the deformation field of collagen gel under controlled mechanical stress. We have also characterized the deformation field generated by invasive breast cancer cells of different morphologies in 3D collagen matrix. In contrast to employ dispersed tracing particles or fluorescently-tagged matrix proteins, our methods provide a label-free, computationally effective strategy to study the cell mechanics in native 3D extracellular matrix. PMID:27304456

  8. Advanced Integrated Traction System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greg Smith; Charles Gough

    2011-08-31

    The United States Department of Energy elaborates the compelling need for a commercialized competitively priced electric traction drive system to proliferate the acceptance of HEVs, PHEVs, and FCVs in the market. The desired end result is a technically and commercially verified integrated ETS (Electric Traction System) product design that can be manufactured and distributed through a broad network of competitive suppliers to all auto manufacturers. The objectives of this FCVT program are to develop advanced technologies for an integrated ETS capable of 55kW peak power for 18 seconds and 30kW of continuous power. Additionally, to accommodate a variety of automotivemore » platforms the ETS design should be scalable to 120kW peak power for 18 seconds and 65kW of continuous power. The ETS (exclusive of the DC/DC Converter) is to cost no more than $660 (55kW at $12/kW) to produce in quantities of 100,000 units per year, should have a total weight less than 46kg, and have a volume less than 16 liters. The cost target for the optional Bi-Directional DC/DC Converter is $375. The goal is to achieve these targets with the use of engine coolant at a nominal temperature of 105C. The system efficiency should exceed 90% at 20% of rated torque over 10% to 100% of maximum speed. The nominal operating system voltage is to be 325V, with consideration for higher voltages. This project investigated a wide range of technologies, including ETS topologies, components, and interconnects. Each technology and its validity for automotive use were verified and then these technologies were integrated into a high temperature ETS design that would support a wide variety of applications (fuel cell, hybrids, electrics, and plug-ins). This ETS met all the DOE 2010 objectives of cost, weight, volume and efficiency, and the specific power and power density 2015 objectives. Additionally a bi-directional converter was developed that provides charging and electric power take-off which is the first

  9. Effects of intermittent traction therapy in an experimental spinal column model.

    PubMed

    Shin, Jeong-Hun; Jun, Seung-lyul; Lee, Young-Jun; Kim, Jae-Hyo; Hwang, Sung-Yeoun; Ahn, Seong-Hun

    2014-04-01

    Traction therapy, which is known to be a treatment method for scoliosis, one of many muscles disease, has been used since Hippocrates introduced it. However, the effects of traction therapy are still not clear. In addition, the meridian sinew theory, which is related to muscle treatment and is mentioned in the book on meridian sinews in the Miraculous Pivot of Huangdi's Internal Classic, has not been the subject of much study. For these reasons, experimental spinal models were made for this study to observe and analyze the lengths of vertebral interspaces after intermittent traction therapy, which is known to be excellent among muscle treatment methods, with various tensile forces. The results showed that the effects of intermittent traction therapy were unclear and that it might be harmful, especially when the pain was induced by muscle weakness. Because the results of this study on intermittent traction therapy were different from those expected from osteopathy or craniosacral theory, better studies of the subject are necessary. Copyright © 2014. Published by Elsevier B.V.

  10. Solid-state transformer-based new traction drive system and control

    NASA Astrophysics Data System (ADS)

    Feng, Jianghua; Shang, Jing; Zhang, Zhixue; Liu, Huadong; Huang, Zihao

    2017-11-01

    A new type of traction drive system consisting of solid-state traction transformer (SSTT), inverter unit, auxiliary inverter, traction motor and other key components is built in order to suit the demand of developing the next-generation electric traction system which will be efficient and lightweight, with high power density. For the purpose of reducing system volume and weight and improving efficiency and grid-side power quality, an efficient SSTT optimized topology combining high-voltage cascaded rectifiers with high-power high-frequency LLC resonant converter is proposed. On this basis, an integrated control strategy built upon synchronous rotating reference frame is presented to achieve unified control over fundamental active, reactive and harmonic components. The carrier-interleaving phase shift modulation strategy is proposed to improve the harmonic performance of cascaded rectifiers. In view of the secondary pulsating existing in a single-phase system, the mathematical model of secondary power transfer is built, and the mechanism of pulsating voltage resulting in beat frequency of LLC resonant converter is revealed, so as to design optimum matching of system parameters. Simulation and experimental results have verified that the traction system and control scheme mentioned in this paper are reasonable and superior and that they meet the future application requirements for rail transit.

  11. Axial traction magnetic resonance imaging (MRI) of the glenohumeral joint in healthy volunteers: initial experience.

    PubMed

    Garwood, Elisabeth R; Souza, Richard B; Zhang, Amy; Zhang, Alan L; Ma, C Benjamin; Link, Thomas M; Motamedi, Daria

    Evaluate technical feasibility and potential applications of glenohumeral (GH) joint axial traction magnetic resonance imaging (MRI) in healthy volunteers. Eleven shoulders were imaged in neutral and with 4kg axial traction at 3T. Quantitative measurements were assessed. Axial traction was well tolerated. There was statistically significant widening of the superior GH joint space (p=0.002) and acromial angle (p=0.017) with traction. Inter-rater agreement was high. GH joint axial traction MRI is technically feasible and well tolerated in volunteers. Traction of the capsule, widening of the superior GH joint space and acromial angle were observed. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Traction of elastohydrodynamic contacts with thermal shearing flow

    NASA Technical Reports Server (NTRS)

    Jakobsen, J.; Winer, W. O.

    1974-01-01

    The formulation and solution for the shear stress and temperature in heavily loaded sliding elastohydrodynamic contacts is presented. The solutions are presented in dimensionless design charts. Integration over the contact area will yield the traction. Accuracy is expected to be very good over the nearly flat part of the contact area where the majority of the sliding traction is generated. The procedure presented is not appropriate for thick film lubrication, for the inlet region, or for the rolling friction of elastohydrodynamic contacts.

  13. An advanced pitch change mechanism incorporating a hybrid traction drive

    NASA Technical Reports Server (NTRS)

    Steinetz, B. M.; Loewenthal, S. H.; Sargisson, D. F.; White, G.

    1984-01-01

    A design of a propeller pitch control mechanism is described that meets the demanding requirements of a high-power, advanced turboprop. In this application, blade twisting moment torque can be comparable to that of the main reduction gearbox output: precise pitch control, reliability and compactness are all at a premium. A key element in the design is a compact, high-ratio hybrid traction drive which offers low torque ripple and high torsional stiffness. The traction drive couples a high speed electric motor/alternator unit to a ball screw that actuates the blade control links. The technical merits of this arrangement and the performance characteristics of the traction drive are discussed.

  14. Traction reveals mechanisms of wall effects for microswimmers near boundaries

    NASA Astrophysics Data System (ADS)

    Shen, Xinhui; Marcos, Fu, Henry C.

    2017-03-01

    The influence of a plane boundary on low-Reynolds-number swimmers has frequently been studied using image systems for flow singularities. However, the boundary effect can also be expressed using a boundary integral representation over the traction on the boundary. We show that examining the traction pattern on the boundary caused by a swimmer can yield physical insights into determining when far-field multipole models are accurate. We investigate the swimming velocities and the traction of a three-sphere swimmer initially placed parallel to an infinite planar wall. In the far field, the instantaneous effect of the wall on the swimmer is well approximated by that of a multipole expansion consisting of a force dipole and a force quadrupole. On the other hand, the swimmer close to the wall must be described by a system of singularities reflecting its internal structure. We show that these limits and the transition between them can be independently identified by examining the traction pattern on the wall, either using a quantitative correlation coefficient or by visual inspection. Last, we find that for nonconstant propulsion, correlations between swimming stroke motions and internal positions are important and not captured by time-averaged traction on the wall, indicating that care must be taken when applying multipole expansions to study boundary effects in cases of nonconstant propulsion.

  15. Traction reveals mechanisms of wall effects for microswimmers near boundaries.

    PubMed

    Shen, Xinhui; Marcos; Fu, Henry C

    2017-03-01

    The influence of a plane boundary on low-Reynolds-number swimmers has frequently been studied using image systems for flow singularities. However, the boundary effect can also be expressed using a boundary integral representation over the traction on the boundary. We show that examining the traction pattern on the boundary caused by a swimmer can yield physical insights into determining when far-field multipole models are accurate. We investigate the swimming velocities and the traction of a three-sphere swimmer initially placed parallel to an infinite planar wall. In the far field, the instantaneous effect of the wall on the swimmer is well approximated by that of a multipole expansion consisting of a force dipole and a force quadrupole. On the other hand, the swimmer close to the wall must be described by a system of singularities reflecting its internal structure. We show that these limits and the transition between them can be independently identified by examining the traction pattern on the wall, either using a quantitative correlation coefficient or by visual inspection. Last, we find that for nonconstant propulsion, correlations between swimming stroke motions and internal positions are important and not captured by time-averaged traction on the wall, indicating that care must be taken when applying multipole expansions to study boundary effects in cases of nonconstant propulsion.

  16. Effect of traction on wrist joint space and cartilage visibility with and without MR arthrography

    PubMed Central

    Griffith, James F; Tang, W K; Ng, Alex W H; Yeung, David K W

    2017-01-01

    Objective: To compare the effect of traction during non-arthrographic and arthrographic MR examination of the wrist with regard to joint space width, joint fluid dispersion and cartilage surface visibility. Methods: Prospective 3-T MRI study of 100 wrists in 96 patients. The first 50 wrists underwent MR arthrography first without traction and then with traction. The following 50 wrists underwent standard MR first without traction and then with traction. On these examinations, two radiologists independently measured (i) joint space width, semi-quantitatively graded (ii) joint fluid dispersion between opposing cartilage surfaces and (iii) articular cartilage surface visibility. The three parameters were compared between the two groups. Results: Traction led to an increase in joint space width at nearly all joints in all patients (p < 0.05), although more so in the arthrography (∆ = 0.08–0.79 mm, all p < 0.05) than in the non-arthrography (∆ = 0.001–0.61 mm, all p < 0.05) group. Joint fluid dispersion and cartilage surface visibility improved after traction in nearly all joints (p < 0.05) in all patients and more so in the arthographic than in the non-arthrography group. Conclusion: Traction did significantly improve cartilage surface visibility for standard MRI of the wrist although the effect was not as great as that seen with MR arthography or MR arthrography with traction. Advances in knowledge: This is the first study to show the beneficial effect of traction during standard non-arthrography MRI of the wrist and compare the effect of traction between non-arthrographic and arthrographic MRI of the wrist. PMID:28181830

  17. Traction-compression-closure for exomphalos major.

    PubMed

    Morabito, Antonino; Owen, Anthony; Bianchi, Adrian

    2006-11-01

    We present our experience with traction-compression-closure (TCC) for exomphalos major (EM) to achieve a safe and embryologically correct midline supraumbilical aesthetic closure with preservation of the umbilicus. Nineteen neonates with EM were paralyzed and ventilated. The abdominal domain was increased by upward cord traction to assist liver-bowel reduction by gravity and sac ligation, followed by circumferential elastic body binder compression. The supraumbilical abdominal wall anomaly cicatrized spontaneously or was closed surgically as a midline scar, with preservation of the umbilicus. Over 7 years (1998-2004), 19 patients with EM were treated by TCC, 18 of whom survived. The patients' median gestational age was 36 weeks (range, 24-40 weeks); their median birth weight was 2312 g (range, 890-3000 g). The median time to reduction was 4 days (range, 3-5 days), whereas that to full enteral feeds was 6 days (range, 4-6 days). Mechanical ventilation for 7 days (range, 6-8 days) was not associated with any morbidity, and the time to home discharge was 11 days (range, 8-12 days). Five patients did not require any surgery. There was no episode of sac rupture or infection. Abdominal expansion by vertical cord traction followed by compression reduction (TCC) under muscle relaxation and ventilation is time well spent toward a safe and aesthetic midline abdominal wall closure without tension for EM.

  18. Traction patterns of tumor cells.

    PubMed

    Ambrosi, D; Duperray, A; Peschetola, V; Verdier, C

    2009-01-01

    The traction exerted by a cell on a planar deformable substrate can be indirectly obtained on the basis of the displacement field of the underlying layer. The usual methodology used to address this inverse problem is based on the exploitation of the Green tensor of the linear elasticity problem in a half space (Boussinesq problem), coupled with a minimization algorithm under force penalization. A possible alternative strategy is to exploit an adjoint equation, obtained on the basis of a suitable minimization requirement. The resulting system of coupled elliptic partial differential equations is applied here to determine the force field per unit surface generated by T24 tumor cells on a polyacrylamide substrate. The shear stress obtained by numerical integration provides quantitative insight of the traction field and is a promising tool to investigate the spatial pattern of force per unit surface generated in cell motion, particularly in the case of such cancer cells.

  19. High Resolution, Large Deformation 3D Traction Force Microscopy

    PubMed Central

    López-Fagundo, Cristina; Reichner, Jonathan; Hoffman-Kim, Diane; Franck, Christian

    2014-01-01

    Traction Force Microscopy (TFM) is a powerful approach for quantifying cell-material interactions that over the last two decades has contributed significantly to our understanding of cellular mechanosensing and mechanotransduction. In addition, recent advances in three-dimensional (3D) imaging and traction force analysis (3D TFM) have highlighted the significance of the third dimension in influencing various cellular processes. Yet irrespective of dimensionality, almost all TFM approaches have relied on a linear elastic theory framework to calculate cell surface tractions. Here we present a new high resolution 3D TFM algorithm which utilizes a large deformation formulation to quantify cellular displacement fields with unprecedented resolution. The results feature some of the first experimental evidence that cells are indeed capable of exerting large material deformations, which require the formulation of a new theoretical TFM framework to accurately calculate the traction forces. Based on our previous 3D TFM technique, we reformulate our approach to accurately account for large material deformation and quantitatively contrast and compare both linear and large deformation frameworks as a function of the applied cell deformation. Particular attention is paid in estimating the accuracy penalty associated with utilizing a traditional linear elastic approach in the presence of large deformation gradients. PMID:24740435

  20. Halo-gravity traction in the treatment of severe spinal deformity: a systematic review and meta-analysis.

    PubMed

    Yang, Changsheng; Wang, Huafeng; Zheng, Zhaomin; Zhang, Zhongmin; Wang, Jianru; Liu, Hui; Kim, Yongjung Jay; Cho, Samuel

    2017-07-01

    Halo-gravity traction has been reported to successfully assist in managing severe spinal deformity. This is a systematic review of all studies on halo-gravity traction in the treatment of spinal deformity to provide information for clinical practice. A comprehensive search was conducted for articles on halo-gravity traction in the treatment of spinal deformity according to the PRISMA guidelines. Appropriate studies would be included and analyzed. Preoperative correction rate of spinal deformity, change of pulmonary function and prevalence of complications were the main measurements. Sixteen studies, a total of 351 patients, were included in this review. Generally, the initial Cobb angle was 101.1° in the coronal plane and 80.5° in the sagittal plane, and it was corrected to 49.4° and 56.0° after final spinal fusion. The preoperative correction due to traction alone was 24.1 and 19.3%, respectively. With traction, the flexibility improved 6.1% but postoperatively the patients did not have better correction. Less aggressive procedures and improved pulmonary function were observed in patients with traction. The prevalence of traction-related complications was 22% and three cases of neurologic complication related to traction were noted. The prevalence of total complications related to surgery was 32% and that of neurologic complications was 1%. Partial correction could be achieved preoperatively with halo-gravity traction, and it may help decrease aggressive procedures, improve preoperative pulmonary function, and reduce neurologic complications. However, traction could not increase preoperative flexibility or final correction. Traction-related complications, although usually not severe, were not rare.

  1. 70. DETAIL OF TRACTION CABLE ENGAGEMENT DEVICE. SMALL, KNOBBED LEVER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    70. DETAIL OF TRACTION CABLE ENGAGEMENT DEVICE. SMALL, KNOBBED LEVER ON BUCKET HANGER WAS PULLED DOWN BY A CAMEL (FIXED CAM RAIL AT CENTER) AS BUCKET ROLLED PAST IT, CAUSING A CLAMP TO CLOSE AGAINST TRACTION CABLE. A SIMILAR CAMEL (NO LONGER EXTANT) DISENGAGED CLAMP ON RECEIVING SIDE. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO

  2. Development of Traction Drive Motors for the Toyota Hybrid System

    NASA Astrophysics Data System (ADS)

    Kamiya, Munehiro

    Toyota Motor Corporation developed in 2005 a new hybrid system for a large SUV. This system included the new development of a high-speed traction drive motor achieving a significant increase in power weight ratio. This paper provides an overview of the hybrid system, discusses the characteristics required of a traction drive motor, and presents the technologies employed in the developed motor.

  3. An advanced pitch change mechanism incorporating a hybrid traction drive

    NASA Technical Reports Server (NTRS)

    Steinetz, B. M.; Sargisson, D. F.; White, G.; Loewenthal, S. H.

    1984-01-01

    A design of a propeller pitch control mechanism is described that meets the demanding requirements of a high-power, advanced turboprop. In this application, blade twisting moment torque can be comparable to that of the main reduction gearbox output: precise pitch control, reliability and compactness are all at a premium. A key element in the design is a compact, high-ratio hybrid traction drive which offers low torque ripple and high torsional stiffness. The traction drive couples a high speed electric motor/alternator unit to a ball screw that actuates the blade control links. The technical merits of this arrangement and the performance characteristics of the traction drive are discussed. Comparisons are made to the more conventional pitch control mechanisms.

  4. Local traction force in the proximal leading process triggers nuclear translocation during neuronal migration.

    PubMed

    Umeshima, Hiroki; Nomura, Ken-Ichi; Yoshikawa, Shuhei; Hörning, Marcel; Tanaka, Motomu; Sakuma, Shinya; Arai, Fumihito; Kaneko, Makoto; Kengaku, Mineko

    2018-04-05

    Somal translocation in long bipolar neurons is regulated by actomyosin contractile forces, yet the precise spatiotemporal sites of force generation are unknown. Here we investigate the force dynamics generated during somal translocation using traction force microscopy. Neurons with a short leading process generated a traction force in the growth cone and counteracting forces in the leading and trailing processes. In contrast, neurons with a long leading process generated a force dipole with opposing traction forces in the proximal leading process during nuclear translocation. Transient accumulation of actin filaments was observed at the dipole center of the two opposing forces, which was abolished by inhibition of myosin II activity. A swelling in the leading process emerged and generated a traction force that pulled the nucleus when nuclear translocation was physically hampered. The traction force in the leading process swelling was uncoupled from somal translocation in neurons expressing a dominant negative mutant of the KASH protein, which disrupts the interaction between cytoskeletal components and the nuclear envelope. Our results suggest that the leading process is the site of generation of actomyosin-dependent traction force in long bipolar neurons, and that the traction force is transmitted to the nucleus via KASH proteins. Copyright © 2018 Elsevier B.V. and Japan Neuroscience Society. All rights reserved.

  5. A modification of the maitland roll top traction table.

    PubMed

    Kneipp, K

    1975-03-01

    This modification of the Maitland Roll Top Traction Table (Maitland, 1973) differs from the original as follows: 1. The two weight-bearing leaves are enclosed by a "guide frame" and the "U-piece" of the original is replaced by a hinged "gate" at the foot, which can be opened downwards for lumbar traction, or can be locked to restrain the leaves when the table is required for other purposes. 2. Four rollers of light steel replace the wooden dowels. 3. The modified table in use by the author is held by a floor peg, and is set up be-between two walls 10' 6″ apart which provide purchase points for traction. Alternatively, purchase at the head end can be taken by hooks attached to the table itself. 4. The design permits a six-foot plinth to be used. Copyright © 1975 Australian Physiotherapy Association. Published by . All rights reserved.

  6. Cellular traction force recovery: An optimal filtering approach in two-dimensional Fourier space.

    PubMed

    Huang, Jianyong; Qin, Lei; Peng, Xiaoling; Zhu, Tao; Xiong, Chunyang; Zhang, Youyi; Fang, Jing

    2009-08-21

    Quantitative estimation of cellular traction has significant physiological and clinical implications. As an inverse problem, traction force recovery is essentially susceptible to noise in the measured displacement data. For traditional procedure of Fourier transform traction cytometry (FTTC), noise amplification is accompanied in the force reconstruction and small tractions cannot be recovered from the displacement field with low signal-noise ratio (SNR). To improve the FTTC process, we develop an optimal filtering scheme to suppress the noise in the force reconstruction procedure. In the framework of the Wiener filtering theory, four filtering parameters are introduced in two-dimensional Fourier space and their analytical expressions are derived in terms of the minimum-mean-squared-error (MMSE) optimization criterion. The optimal filtering approach is validated with simulations and experimental data associated with the adhesion of single cardiac myocyte to elastic substrate. The results indicate that the proposed method can highly enhance SNR of the recovered forces to reveal tiny tractions in cell-substrate interaction.

  7. Traction alopecia: the root of the problem.

    PubMed

    Billero, Victoria; Miteva, Mariya

    2018-01-01

    Traction alopecia (TA) affects one-third of women of African descent who wear various forms of traumatic hairstyling for a prolonged period of time. The risk of TA is increased by the extent of pulling and duration of traction, as well as the use of chemical relaxation. The frequent use of tight buns or ponytails, the attachment of weaves or hair extensions, and tight braids (such as cornrows and dreadlocks) are believed to be the highest risk hairstyles. TA can also occur in the setting of religious and occupational traumatic hairstyling. In its later stages, the disease may progress into an irreversible scarring alopecia if traumatic hairstyling continues without appropriate intervention. The most common clinical presentation includes marginal alopecia and non-marginal patchy alopecia. A clue to the clinical diagnosis is the preservation of the fringe sign as opposed to its loss in frontal fibrosing alopecia (FFA). Dermoscopy can be helpful in the diagnosis and can detect the ongoing traction by the presence of hair casts. Histopathology can distinguish TA from alopecia areata, FFA, and patchy central centrifugal cicatricial alopecia. Currently, there is no cure. Therefore, it is imperative that clinicians educate high-risk populations about TA and those practices that may convey the risk of hair loss.

  8. Traction alopecia: the root of the problem

    PubMed Central

    Billero, Victoria; Miteva, Mariya

    2018-01-01

    Traction alopecia (TA) affects one-third of women of African descent who wear various forms of traumatic hairstyling for a prolonged period of time. The risk of TA is increased by the extent of pulling and duration of traction, as well as the use of chemical relaxation. The frequent use of tight buns or ponytails, the attachment of weaves or hair extensions, and tight braids (such as cornrows and dreadlocks) are believed to be the highest risk hairstyles. TA can also occur in the setting of religious and occupational traumatic hairstyling. In its later stages, the disease may progress into an irreversible scarring alopecia if traumatic hairstyling continues without appropriate intervention. The most common clinical presentation includes marginal alopecia and non-marginal patchy alopecia. A clue to the clinical diagnosis is the preservation of the fringe sign as opposed to its loss in frontal fibrosing alopecia (FFA). Dermoscopy can be helpful in the diagnosis and can detect the ongoing traction by the presence of hair casts. Histopathology can distinguish TA from alopecia areata, FFA, and patchy central centrifugal cicatricial alopecia. Currently, there is no cure. Therefore, it is imperative that clinicians educate high-risk populations about TA and those practices that may convey the risk of hair loss. PMID:29670386

  9. Candidate Coatings and Dry Traction Drives for Planetary Vehicles

    NASA Technical Reports Server (NTRS)

    Fusaro, Robert; Oswald, Fred B.

    2002-01-01

    Robert Fusaro and Fred Oswald of the Mechanical Components Branch discussed 'Candidate Coatings and Dry Traction Drives for Planetary Vehicles'. Vehicles to be designed for exploration of planets and moons of the solar system will require reliable mechanical drives to operate efficiently. Long-term operation of these drives will be challenging because of extreme operating conditions. These extreme conditions include: very high and/or very cold temperatures, wide temperature ranges, dust, vacuum or low-pressure atmospheres, and corrosive environments. Most drives used on Earth involve oil-lubricated gears. However, due to the extreme conditions on planetary surfaces, it may not be advisable or even possible to use oil lubrication. Unfortunately, solid lubricants do not work well when applied to gears because of the high contact stress conditions and large sliding motion between the teeth, which cause wear and limit life. We believe traction drives will provide an attractive alternative to gear drives. Traction drives are composed of rollers that provide geometry more conducive to solid lubrication. Minimal slip occurs in this contact geometry and thus there is very low wear to the solid lubricant. The challenge for these solid-lubricated drives is finding materials or coatings that provide the required long-life while also providing high traction. We seek materials that provide low wear with high friction.

  10. Asymmetry of activation of lateral abdominal muscles during the neurodevelopmental traction technique.

    PubMed

    Gogola, Anna; Gnat, Rafał; Zaborowska, Małgorzata; Dziub, Dorota; Gwóźdź, Michalina

    2018-01-01

    The aim of the study was to evaluate the symmetry and pattern of activation of lateral abdominal muscles (LAM) in response to neurodevelopmental traction technique. Measurements of LAM thickness were performed in four experimental conditions: during traction with the force of 5% body weight (5% traction): 1) in neutral position, 2) in 20° posterior trunk inclination; during traction with the force of 15% body weight (15% traction): 3) in neutral position, 4) in 20° posterior trunk inclination. Thirty-seven healthy children participated in the study. Not applicable. To evaluate LAM activation level ultrasound technology was employed (two Mindray DP660 devices (Mindray, Shenzhen, China) with 75L38EA linear probes). An experiment with repeated measurements of the dependent variables was conducted. Side-to-side LAM activation asymmetry showed relatively high magnitude, however, significant difference was found only in case of the obliquus externus (OE) during stronger traction (P < 0.05). The magnitude of LAM thickness change formed a gradient, with the most profound transversus abdominis (TrA) showing the smallest change, and the most superficial OE - the greatest. The inter-muscle differences were most pronounced between the OE and TrA (P < 0.001). During the neurodevelopmental traction technique there is a difference in individual LAM activation level, with deeper muscles showing less intense activation. In statistical terms, the only signs of side-to-side asymmetry of LAM activation are visible in case of the OE, however, the magnitude of asymmetry is relatively high. The results allow to identify patterns of activation of LAM in children showing typical development that will serve as a reference in future studies in children with neurological disorder. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Ventriculoperitoneal Shunt Fracture Following Application of Halo-Gravity Traction: A Case Report.

    PubMed

    Blakeney, William G; D'Amato, Charles

    2015-09-01

    Ventriculoperitoneal (VP) shunt malfunctions are very common, and shunt fracture is one of the most common causes. Shunt fractures are often a result of calcification and tethering, which predispose the tubing to fracture when mechanical stresses are applied. This case report describes a case of shunt fracture following application of halo-gravity traction for correction of spinal deformity. Chart and imaging data for a single case were reviewed and reported in this retrospective case study. A 10-year-old female, being treated for syndromic scoliosis, underwent posterior surgical release and application of halo-gravity traction. Increasing weight of traction was applied over a period of 6 weeks, for gradual deformity correction. It was noted on the 6-week cervical spine radiograph that the VP shunt had fractured at the base of the neck. The patient was taken to the operating room and intraoperative findings confirmed shunt fracture. This was repaired without complications. This case, to our best knowledge, is the first reported occurrence of shunt fracture following application of halo-gravity traction. It demonstrates the importance of careful monitoring of patients with VP shunts, when they are undergoing traction for correction of spinal deformity. Level IV.

  12. Experimental studies about the impact of traction sand on urban road dust composition.

    PubMed

    Kupiainen, Kaarle; Tervahattu, Heikki; Räisänen, Mika

    2003-06-01

    Traffic causes enhanced PM(10) resuspension especially during spring in the US, Japan, Norway, Sweden and Finland, among other countries. The springtime PM(10) consists primarily of mineral matter from tyre-induced paved road surface wear and traction sand. In some countries, the majority of vehicles are equipped with studded tyres to enhance traction, which additionally increases road surface wear. Because the traction sand and the mineral matter from the pavement aggregate can have a similar mineralogical composition, it has been difficult to determine the source of the mineral fraction in the PM(10). In this study, homogenous traction sand and pavement aggregate with different mineralogical compositions were chosen to determine the sources of PM(10) particles by single particle analysis (SEM/EDX). This study was conducted in a test facility, which made it possible to rule out dust contributions from other sources. The ambient PM(10) concentrations were higher when traction sand was used, regardless of whether the tyres were studded or not. Surprisingly, the use of traction sand greatly increased the number of the particles originating from the pavement. It was concluded that sand must contribute to pavement wear. This phenomenon is called the sandpaper effect. An understanding of this is important to reduce harmful effects of springtime road dust in practical winter maintenance of urban roads

  13. The impact of the neurodevelopmental traction technique on activation of lateral abdominal muscles in children aged 11-13 years.

    PubMed

    Gogola, Anna; Gnat, Rafał; Dziub, Dorota; Gwóźdź, Michalina; Zaborowska, Małgorzata

    2016-06-27

    The aim of the study was to evaluate the activation of lateral abdominal muscles (LAM) in response to neurodevelopmental traction technique as assessed by ultrasounds as well as to compare the effects of different traction forces. An experiment with repeated measurements of the dependent variables was conducted. Thirty-seven children (22 girls) participated. Measurements of LAM thickness (indicating LAM activation) were performed bilaterally during traction of 5% body weight: 1) in neutral position, 2) in 20° posterior trunk inclination; during traction of 15% body weight: 3) in neutral position, 4) in 20° posterior trunk inclination. The ultrasound technology was employed. When applying the lighter traction the superficial LAM (external and internal oblique muscles) showed significant changes. The mean thickness of both muscles during traction increased (both p < 0.001). The deepest transversus abdominis showed no response (p > 0.05). Stronger traction elicited smaller changes. External and internal oblique muscles showed significant increases (p < 0.001, p < 0.01, respectively). Transversus abdominis became less thick during stronger traction (p < 0.01). The neurodevelopmental traction technique elicits the changes in LAM thickness in children with typical development. The superficial LAM show more distinct responses than the profound LAM. Stronger traction induces smaller LAM thickness changes than lighter traction.

  14. Severe Postoperative Complications may be Related to Mesenteric Traction Syndrome during Open Esophagectomy.

    PubMed

    Ambrus, R; Svendsen, L B; Secher, N H; Goetze, J P; Rünitz, K; Achiam, M P

    2017-09-01

    During abdominal surgery, traction of the mesenterium provokes mesenteric traction syndrome, including hypotension, tachycardia, and flushing, along with an increase in plasma prostacyclin (PGI 2 ). We evaluated whether postoperative complications are related to mesenteric traction syndrome during esophagectomy. Flushing, hemodynamic variables, and plasma 6-keto-PGF 1α were recorded during the abdominal part of open ( n = 25) and robotically assisted ( n = 25) esophagectomy. Postoperative complications were also registered, according to the Clavien-Dindo classification. Flushing appeared in 17 (open) and 5 (robotically assisted) surgical cases ( p = 0.001). Mean arterial pressure was stable during both types of surgeries, but infusion of vasopressors during the first hour of open surgery was related to development of widespread (Grade II) flushing ( p = 0.036). For patients who developed flushing, heart rate and plasma 6-keto-PGF 1α also increased ( p = 0.001 and p < 0.001, respectively). Furthermore, severe postoperative complications were related to Grade II flushing ( p = 0.037). Mesenteric traction syndrome manifests more frequently during open than robotically assisted esophagectomy, and postoperative complications appear to be associated with severe mesenteric traction syndrome.

  15. Design study of toroidal traction CVT for electric vehicles

    NASA Technical Reports Server (NTRS)

    Raynard, A. E.; Kraus, J.; Bell, D. D.

    1980-01-01

    The development, evaluation, and optimization of a preliminary design concept for a continuously variable transmission (CVT) to couple the high-speed output shaft of an energy storage flywheel to the drive train of an electric vehicle is discussed. An existing computer simulation program was modified and used to compare the performance of five CVT design configurations. Based on this analysis, a dual-cavity full-toroidal drive with regenerative gearing is selected for the CVT design configuration. Three areas are identified that will require some technological development: the ratio control system, the traction fluid properities, and evaluation of the traction contact performance. Finally, the suitability of the selected CVT design concept for alternate electric and hybrid vehicle applications and alternate vehicle sizes and maximum output torques is determined. In all cases the toroidal traction drive design concept is applicable to the vehicle system. The regenerative gearing could be eliminated in the electric powered vehicle because of the reduced ratio range requirements. In other cases the CVT with regenerative gearing would meet the design requirements after appropriate adjustments in size and reduction gearing ratio.

  16. Surgical management of retinal diseases: proliferative diabetic retinopathy and traction retinal detachment.

    PubMed

    Cruz-Iñigo, Yousef J; Acabá, Luis A; Berrocal, Maria H

    2014-01-01

    Current indications for pars plana vitrectomy in patients with proliferative diabetic retinopathy (PDR) include vitreous hemorrhage, tractional retinal detachment (TRD), combined tractional and rhegmatogenous retinal detachment (CTRRD), diabetic macular edema associated with posterior hyaloidal traction, and anterior segment neovascularization with media opacities. This chapter will review the indications, surgical objectives, adjunctive pharmacotherapy, microincision surgical techniques, and outcomes of diabetic vitrectomy for PDR, TRD, and CTRRD. With the availability of new microincision vitrectomy technology, wide-angle microscope viewing systems, and pharmacologic agents, vitrectomy can improve visual acuity and achieve long-term anatomic stability in eyes with severe complications from PDR. © 2014 S. Karger AG, Basel

  17. Traction injury of the recurrent laryngeal nerve: Results of continuous intraoperative neuromonitoring in a swine model.

    PubMed

    Lee, Hye Yoon; Cho, Young Geon; You, Ji Young; Choi, Byoung Ho; Kim, Joon Yub; Wu, Che-Wei; Chiang, Feng-Yu; Kim, Hoon Yub

    2016-04-01

    Recurrent laryngeal nerve (RLN) palsy is the most serious complication after thyroidectomy. However, little is known about the degree of traction injury that causes loss of signal. The purpose of this study was to evaluate traction injuries in the swine RLN using continuous intraoperative neuromonitoring (IONM) and determine the traction power that results in loss of signal. Thirteen swine underwent traction injury to the RLNs with continuous IONM, and stress-strain curves were determined for 8 nerves using the universal material testing machine in an ex vivo model. Traction injury at a mean power of 2.83 MPa caused loss of signal. The mean physiologic limit strain and tensile strength of the swine RLNs were found to be 15.0% and 4.9 MPa, respectively. Histological analysis showed no abnormal structural findings. Traction injury of swine RLNs causes loss of signal at a power of 2.83 MPa. However, all injured nerves recovered within 7 days with no observed structural damage. © 2015 Wiley Periodicals, Inc.

  18. Applications of Traction Force Microscopy in Measuring Adhesion Molecule Dependent Cell Contractility

    ERIC Educational Resources Information Center

    Mann, Cynthia Marie

    2009-01-01

    This work describes the use of polyacrylamide hydrogels as controlled elastic modulus substrates for single cell traction force microscopy studies. The first section describes the use of EDC/NHS chemistry to convalently link microbeads to the hydrogel matrix for the purpose of performing long-term traction force studies (7 days). The final study…

  19. Orthodontic traction of a transmigrated mandibular canine using mini-implant: a case report and review.

    PubMed

    Plaza, Sonia Patricia

    2016-12-01

    The patient in this case is an 11-year-old girl, whose mandibular left canine was transmigrated. The traction to the arch was assisted by using a temporary skeletal anchorage device. After 5 months of poor response to traction, the biomechanics were re-adjusted, obtaining effective traction in to the arch in 12 months. After this period, the treatment was completed with fixed orthodontic appliances.

  20. Footwear traction and three-dimensional kinematics of level, downhill, uphill and cross-slope walking.

    PubMed

    Wannop, John W; Worobets, Jay T; Ruiz, Rodrigo; Stefanyshyn, Darren J

    2014-01-01

    Outdoor activities are a popular form of recreation, with hiking being the most popular outdoor activity as well as being the most prevalent in terms of injury. Over the duration of a hike, trekkers will encounter many different sloped terrains. Not much is known about the required traction or foot-floor kinematics during locomotion on these sloped surfaces, therefore, the purpose was to determine the three-dimensional foot-floor kinematics and required traction during level, downhill, uphill and cross-slope walking. Ten participants performed level, uphill, downhill and cross-slope walking along a 19° inclined walkway. Ground reaction force data as well as 3D positions of retro reflective markers attached to the shoe were recorded using a Motion Analysis System. Peak traction coefficients and foot-floor kinematics during sloped walking were compared to level walking. When walking along different sloped surfaces, the required traction coefficients at touchdown were not different from level walking, therefore, the increased likelihood of heel slipping during hiking is potentially due to the presence of loose material (rocks, dirt) on hiking slopes, rather than the overall lack of traction. Differences in required traction were seen at takeoff, with uphill and cross-sloped walking requiring a greater amount of traction compared to level walking. Changes in sagittal plane, frontal plane and transverse plane foot-floor angles were seen while walking on the sloped surfaces. Rapid foot-floor eversion was observed during cross-slope walking which could place the hiker at risk of injury with a misstep or if there was a slight slip. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. A micropatterning and image processing approach to simplify measurement of cellular traction forces

    PubMed Central

    Polio, Samuel R.; Rothenberg, Katheryn E.; Stamenović, Dimitrije; Smith, Michael L.

    2012-01-01

    Quantification of the traction forces that cells apply to their surroundings has been critical to the advancement of our understanding of cancer, development and basic cell biology. This field was made possible through the development of engineered cell culture systems that permit optical measurement of cell-mediated displacements and computational algorithms that allow conversion of these displacements into stresses and forces. Here, we present a novel advancement of traction force microscopy on polyacrylamide (PAA) gels that addresses limitations of existing technologies. Through an indirect patterning technique, we generated PAA gels with fluorescent 1 μm dot markers in a regularized array. This improves existing traction measurements since (i) multiple fields of view can be measured in one experiment without the need for cell removal; (ii) traction vectors are modeled as discrete point forces, and not as a continuous field, using an extremely simple computational algorithm that we have made available online; and (iii) the pattern transfer technique is amenable to any of the published techniques for producing patterns on glass. In the future, this technique will be used for measuring traction forces on complex patterns with multiple, spatially distinct ligands in systems for applying strain to the substrate, and in sandwich cultures that generate quasi-three-dimensional environments for cells. PMID:21884832

  2. Measurement of the traction force of biological cells by digital holography

    PubMed Central

    Yu, Xiao; Cross, Michael; Liu, Changgeng; Clark, David C.; Haynie, Donald T.; Kim, Myung K.

    2011-01-01

    The traction force produced by biological cells has been visualized as distortions in flexible substrata. We have utilized quantitative phase microscopy by digital holography (DH-QPM) to study the wrinkling of a silicone rubber film by motile fibroblasts. Surface deformation and the cellular traction force have been measured from phase profiles in a direct and straightforward manner. DH-QPM is shown to provide highly efficient and versatile means for quantitatively analyzing cellular motility. PMID:22254175

  3. Influence of basketball shoe mass, outsole traction, and forefoot bending stiffness on three athletic movements.

    PubMed

    Worobets, Jay; Wannop, John William

    2015-09-01

    Prior research has shown that footwear can enhance athletic performance. However, public information is not available on what basketball shoe properties should be selected to maximise movement performance. Therefore, the purpose of the study was to investigate the influence of basketball shoe mass, outsole traction, and forefoot bending stiffness on sprinting, jumping, and cutting performance. Each of these three basketball shoe properties was systematically varied by ± 20% to produce three shoe conditions of varying mass, three conditions of varying traction, and three conditions of varying bending stiffness. Each shoe was tested by 20 recreational basketball players completing maximal effort sprints, vertical jumps, and a cutting drill. Outsole traction had the largest influence on performance, as the participants performed significantly worse in all tests when traction was decreased by 20% (p < 0.001), and performed significantly better in the cutting drill when traction was increased by 20% (p = 0.005). Forefoot bending stiffness had a moderate effect on sprint and cutting performance (p = 0.013 and p = 0.016 respectively) and shoe mass was found to have no effect on performance. Therefore, choosing a shoe with relatively high outsole traction and forefoot bending stiffness should be prioritised, and less concern should be focused on selecting the lightest shoe.

  4. Wrist Traction During MR Arthrography Improves Detection of Triangular Fibrocartilage Complex and Intrinsic Ligament Tears and Visibility of Articular Cartilage.

    PubMed

    Lee, Ryan K L; Griffith, James F; Ng, Alex W H; Nung, Ryan C H; Yeung, David K W

    2016-01-01

    The purpose of this study was to assess the effects of traction during MR arthrography of the wrist on joint space widening, cartilage visibility, and detection of tears of the triangular fibrocartilage complex (TFCC) and intrinsic ligaments. A prospective study included 40 wrists in 39 patients (25 men, 14 women; mean age, 35 years). MR arthrography was performed with a 3-T MRI system with and without axial traction. Two radiologists independently measured wrist and carpal joint space widths and semiquantitatively graded articular cartilage visibility. Using conventional arthrography as the reference standard and working in consensus, they assessed for the presence of tears of the TFCC, lunotriquetral ligament (LTL), and scapholunate ligament (SLL). Visibility of a tear before traction was compared with visibility after traction. With traction, all joint spaces in the wrist and carpus were significantly widened (change, 0.15-1.01 mm; all p < 0.006). Subjective cartilage visibility of all joint spaces improved after traction (all p ≤ 0.048) except for that of the radioscaphoid space, which was well visualized even before traction. Conventional arthrography depicted 24 TFCC tears, seven LTL tears, and three SLL tears. The accuracy of tear detection improved after traction for the TFCC (98% after traction vs 83% before traction), the LTL (100% vs 88%), and the SLL (100% vs 95%). Tear visibility improved after traction for 54% of TFCC tears, 71% of LTL tears, and 66% of SLL tears. Wrist MR arthrography with axial traction significantly improved the visibility of articular cartilage and the detection and visibility of tears of the TFCC and intrinsic ligaments. The results favor more widespread use of traction during MR arthrography of the wrist.

  5. The results of preoperative halo-gravity traction in children with severe spinal deformity.

    PubMed

    Garabekyan, Tigran; Hosseinzadeh, Pooya; Iwinski, Henry J; Muchow, Ryan D; Talwalkar, Vishwas R; Walker, Janet; Milbrandt, Todd A

    2014-01-01

    Halo-gravity traction has been used preoperatively for patients with severe spinal deformity but there are limited data in the literature on the results and complications. We studied the outcomes of perioperative halo-gravity traction in children with severe spinal deformity. A retrospective study was carried out on patients who were treated at our center. Twenty-one patients were included in the study. Radiographic and pulmonary function parameters showed significant improvement during the course of traction and at the final follow-up. The overall complication rate was 19%, including two patients with pin loosening and two patients with superficial pin-site infections treated with oral antibiotics.

  6. An Inverter Packaging Scheme for an Integrated Segmented Traction Drive System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su, Gui-Jia; Tang, Lixin; Ayers, Curtis William

    The standard voltage source inverter (VSI), widely used in electric vehicle/hybrid electric vehicle (EV/HEV) traction drives, requires a bulky dc bus capacitor to absorb the large switching ripple currents and prevent them from shortening the battery s life. The dc bus capacitor presents a significant barrier to meeting inverter cost, volume, and weight requirements for mass production of affordable EVs/HEVs. The large ripple currents become even more problematic for the film capacitors (the capacitor technology of choice for EVs/HEVs) in high temperature environments as their ripple current handling capability decreases rapidly with rising temperatures. It is shown in previous workmore » that segmenting the VSI based traction drive system can significantly decrease the ripple currents and thus the size of the dc bus capacitor. This paper presents an integrated packaging scheme to reduce the system cost of a segmented traction drive.« less

  7. Naegele Forceps Delivery and Association between Morbidity and the Number of Forceps Traction Applications: A Retrospective Study.

    PubMed

    Matsumoto, Naoki; Takenaka, Toshifumi; Ikeda, Nobuyuki; Yazaki, Satoshi; Sato, Yuichi

    2015-01-01

    To present the method of Naegele forceps delivery clinically practiced by the lead author, its success rate, and morbidity and to evaluate the relationship between morbidity and the number of forceps traction applications. Naegele forceps delivery was performed when the fetal head reached station +2 cm, the forceps were applied in the maternal pelvic application, and traction was slowly and gently performed. In the past two years, Naegele forceps delivery was attempted by the lead author in 87 cases, which were retrospectively reviewed. The numbers of traction applications were one in 64.7% of cases, two in 24.7%, and three or more in 10.7%. The success rate was 100%. No severe morbidity was observed in mothers or neonates. Neonatal facial injury occurred most commonly in cases with fetal head malrotation, elevated numbers of traction applications, and maternal complications. Umbilical artery acidemia most commonly occurred in cases with nonreassuring fetal status. The significant crude odds ratio for three or more traction applications was 20 in cases with malrotation. Naegele forceps delivery has a high success rate, but multiple traction applications will sometimes be required, particularly in cases with malrotation. Malrotation and elevated numbers of traction applications may lead to neonatal head damage.

  8. Friction-Controlled Traction Force in Cell Adhesion

    PubMed Central

    Pompe, Tilo; Kaufmann, Martin; Kasimir, Maria; Johne, Stephanie; Glorius, Stefan; Renner, Lars; Bobeth, Manfred; Pompe, Wolfgang; Werner, Carsten

    2011-01-01

    The force balance between the extracellular microenvironment and the intracellular cytoskeleton controls the cell fate. We report a new (to our knowledge) mechanism of receptor force control in cell adhesion originating from friction between cell adhesion ligands and the supporting substrate. Adherent human endothelial cells have been studied experimentally on polymer substrates noncovalently coated with fluorescent-labeled fibronectin (FN). The cellular traction force correlated with the mobility of FN during cell-driven FN fibrillogenesis. The experimental findings have been explained within a mechanistic two-dimensional model of the load transfer at focal adhesion sites. Myosin motor activity in conjunction with sliding of FN ligands noncovalently coupled to the surface of the polymer substrates is shown to result in a controlled traction force of adherent cells. We conclude that the friction of adhesion ligands on the supporting substrate is important for mechanotransduction and cell development of adherent cells in vitro and in vivo. PMID:22004739

  9. Traction force during vacuum extraction: a prospective observational study.

    PubMed

    Pettersson, K; Ajne, J; Yousaf, K; Sturm, D; Westgren, M; Ajne, G

    2015-12-01

    To investigate the traction force employed during vacuum extractions. Observational cross-sectional study. Obstetric Department, Karolinska University Hospital, Sweden, and the Swedish National Congress of Obstetrics and Gynaecology, 2013. Two hundred women with vacuum extraction at term and 130 obstetricians participating in a simulated setting. In a normal clinical setting, we used a specially adapted device to measure and record the force used to undertake vacuum extraction. In a subsequent part of the study, the force employed for vacuum extraction by a group of obstetricians in a fictive setting was estimated and objectively measured. Applied force during vacuum extraction in relation to the estimated level of difficulty in the delivery; perinatal diagnoses of asphyxia or head trauma; estimated force compared with objectively measured force employed in the fictive setting. The median (minimum-maximum) peak forces for minimum, average and excessive vacuum extraction in the clinical setting were 176 N (5-360 N), 225 N (115-436 N), and 241 N (164-452 N), respectively. In 34% of cases a force in excess of 216 N was employed. There was no correlation between the umbilical arterial pH at delivery and the traction force employed during extraction. Four cases of mild hypoxic ischaemic encephalopathy were observed, three of which were associated with a delivery whereby excessive traction force was employed during the vacuum extraction. In the fictive setting, the actual exerted force was twice the quantitative estimation. The measured forces in the clinical setting were four times higher than that estimated in the fictive setting. Higher than expected levels of traction force were used for vacuum extraction delivery. As obstetricians tend to underestimate the force applied during vacuum extraction, objective measurement with instantaneous feedback may be valuable in raising awareness. © 2015 Royal College of Obstetricians and Gynaecologists.

  10. Application of low-order potential solutions to higher-order vertical traction boundary problems in an elastic half-space

    PubMed Central

    Taylor, Adam G.

    2018-01-01

    New solutions of potential functions for the bilinear vertical traction boundary condition are derived and presented. The discretization and interpolation of higher-order tractions and the superposition of the bilinear solutions provide a method of forming approximate and continuous solutions for the equilibrium state of a homogeneous and isotropic elastic half-space subjected to arbitrary normal surface tractions. Past experimental measurements of contact pressure distributions in granular media are reviewed in conjunction with the application of the proposed solution method to analysis of elastic settlement in shallow foundations. A numerical example is presented for an empirical ‘saddle-shaped’ traction distribution at the contact interface between a rigid square footing and a supporting soil medium. Non-dimensional soil resistance is computed as the reciprocal of normalized surface displacements under this empirical traction boundary condition, and the resulting internal stresses are compared to classical solutions to uniform traction boundary conditions. PMID:29892456

  11. Temperature control of power semiconductor devices in traction applications

    NASA Astrophysics Data System (ADS)

    Pugachev, A. A.; Strekalov, N. N.

    2017-02-01

    The peculiarity of thermal management of traction frequency converters of a railway rolling stock is highlighted. The topology and the operation principle of the automatic temperature control system of power semiconductor modules of the traction frequency converter are designed and discussed. The features of semiconductors as an object of temperature control are considered; the equivalent circuit of thermal processes in the semiconductors is suggested, the power losses in the two-level voltage source inverters are evaluated and analyzed. The dynamic properties and characteristics of the cooling fan induction motor electric drive with the scalar control are presented. The results of simulation in Matlab are shown for the steady state of thermal processes.

  12. Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison.

    PubMed

    Schmaranzer, Florian; Klauser, Andrea; Kogler, Michael; Henninger, Benjamin; Forstner, Thomas; Reichkendler, Markus; Schmaranzer, Ehrenfried

    2015-06-01

    To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. • The used traction technique was well tolerated by most patients. • The used traction technique almost consistently achieved separation of cartilage layers. • Traction MR arthrography enabled accurate detection of chondral and labral lesions.

  13. Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum

    PubMed Central

    Henak, C.R.; Abraham, C.L.; Peters, C.L.; Sanders, R.K.; Weiss, J.A.; Anderson, A.E.

    2014-01-01

    AIM To develop and demonstrate the efficacy of a computed tomography arthrography (CTA) protocol for the hip that enables accurate three-dimensional reconstructions of cartilage and excellent visualization of the acetabular labrum. MATERIALS AND METHODS Ninety-three subjects were imaged (104 scans); 68 subjects with abnormal anatomy, 11 patients after periacetabular osteotomy surgery, and 25 subjects with normal anatomy. Fifteen to 25 ml of contrast agent diluted with lidocaine was injected using a lateral oblique approach. A Hare traction splint applied traction during CT. The association between traction force and intra-articular joint space was assessed qualitatively under fluoroscopy. Cartilage geometry was reconstructed from the CTA images for 30 subjects; the maximum joint space under traction was measured. RESULTS Using the Hare traction splint, the intra-articular space and boundaries of cartilage could be clearly delineated throughout the joint; the acetabular labrum was also visible. Dysplastic hips required less traction (~5 kg) than normal and retroverted hips required (>10 kg) to separate the cartilage. An increase in traction force produced a corresponding widening of the intra-articular joint space. Under traction, the maximum width of the intra-articular joint space during CT ranged from 0.98–6.7 mm (2.46 ± 1.16 mm). CONCLUSIONS When applied to subjects with normal and abnormal hip anatomy, the CTA protocol presented yields clear delineation of the cartilage and the acetabular labrum. Use of a Hare traction splint provides a simple, cost-effective method to widen the intra-articular joint space during CT, and provides flexibility to vary the traction as required. PMID:25070373

  14. Traction free finite elements with the assumed stress hybrid model. M.S. Thesis, 1981

    NASA Technical Reports Server (NTRS)

    Kafie, Kurosh

    1991-01-01

    An effective approach in the finite element analysis of the stress field at the traction free boundary of a solid continuum was studied. Conventional displacement and assumed stress finite elements were used in the determination of stress concentrations around circular and elliptical holes. Specialized hybrid elements were then developed to improve the satisfaction of prescribed traction boundary conditions. Results of the stress analysis indicated that finite elements which exactly satisfy the free stress boundary conditions are the most accurate and efficient in such problems. A general approach for hybrid finite elements which incorporate traction free boundaries of arbitrary geometry was formulated.

  15. Posterior-only surgery with preoperative skeletal traction for management of severe scoliosis.

    PubMed

    Mehrpour, Saeedreza; Sorbi, Reza; Rezaei, Reza; Mazda, Keyvan

    2017-04-01

    The surgical treatment of severe adolescent spinal deformities is challenging and carries substantial risks of mortality and morbidity. To mitigate this risk, surgeons have employed various methods as this study designed to evaluate the safety and effectiveness of preoperative halo-femoral or halo gravity traction (HGT) followed by posterior-only surgery in the management of severe scoliosis. A total number of 23 patients with severe scoliosis treated by preoperative skeletal traction (halo gravity or halo femoral) followed by posterior fusion and instrumentation in one stage. All patients were followed for a minimum of 2 years after surgery. The average age of the patients was 12.7 years at the time of surgery. Mean of the Cobb angle improved from 99.9° ± 8.2° preoperatively to 75.3° ± 8° post-traction and 49.5° ± 7.7° postoperatively. Kyphosis angle corrected from 56.4° ± 9.5° to 38.6° ± 5.8°. The preop-FVC% was 41 ± 6.1% and after 1 year follow-up FVC% was 45.7 ± 7.7%. No patients required an anterior release due to amount of their deformity. Despite the benefits of modern instrumentation procedures, the treatment of severe scoliosis can be very competing. We think that by applying preoperative halo femoral traction and halo-gravity traction, managing severe scoliosis will be in safe and easy manner and can lead to better deformity correction and less neurological complications and facilitate to avoid anterior operation for severe scoliosis and its related complications.

  16. Intravenous nitroglycerin for controlled cord traction in the management of retained placenta.

    PubMed

    Visalyaputra, Shusee; Prechapanich, Japarath; Suwanvichai, Sukanya; Yimyam, Suwimol; Permpolprasert, Ladda; Suksopee, Pattipa

    2011-02-01

    To determine the effect of 200 μg of intravenous nitroglycerin in the release of retained placenta by controlled cord traction. In this randomized controlled study, 40 women with a placenta retained for 30 minutes received intravenously 200 μg of nitroglycerin or a normal saline solution before umbilical cord traction was initiated. The rates of successful removal of the retained placenta in the study (n=20) and control (n=20) groups were compared, as were blood pressure, pulse rate, blood loss, and adverse effects. The placenta was released in only 15% and 20% of the participants in the study and control group, respectively. The remainder of the participants required general anesthesia and manual removal of the retained placenta regardless of group assignation. Blood pressure fell in significantly more women in the study group, but there were no differences in estimated blood loss or minor adverse effects. Intravenously administered nitroglycerin did not facilitate the release of retained placenta by umbilical cord traction. However, cord traction may be performed longer than 30 minutes to attempt releasing the placenta before operative manual removal is initiated. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  17. The effect of tibio-femoral traction mobilization on passive knee flexion motion impairment and pain: a case series

    PubMed Central

    Maher, Sara; Creighton, Doug; Kondratek, Melodie; Krauss, John; Qu, Xianggui

    2010-01-01

    The purpose of this case series was to explore the effects of tibio-femoral (TF) manual traction on pain and passive range of motion (PROM) in individuals with unilateral motion impairment and pain in knee flexion. Thirteen participants volunteered for the study. All participants received 6 minutes of TF traction mobilization applied at end-range passive knee flexion. PROM measurements were taken before the intervention and after 2, 4, and 6 minutes of TF joint traction. Pain was measured using a visual analog scale with the TF joint at rest, at end-range passive knee flexion, during the application of joint traction, and immediately post-treatment. There were significant differences in PROM after 2 and 4 minutes of traction, with no significance noted after 4 minutes. A significant change in knee flexion of 25.9°, which exceeded the MDC95, was found when comparing PROM measurements pre- to final intervention. While pain did not change significantly over time, pain levels did change significantly during each treatment session. Pain significantly increased when the participant’s knee was passively flexed to end range; it was reduced, although not significantly, during traction mobilization; and it significantly decreased following traction. This case series supports TF joint traction as a means of stretching shortened articular and periarticular tissues without increasing reported levels of pain during or after treatment. In addition, this is the first study documenting the temporal aspects of treatment effectiveness in motion restoration. PMID:21655421

  18. Traction force microscopy in rapidly moving cells reveals separate roles for ROCK and MLCK in the mechanics of retraction.

    PubMed

    Morin, Timothy R; Ghassem-Zadeh, Sean A; Lee, Juliet

    2014-08-15

    Retraction is a major rate-limiting step in cell motility, particularly in slow moving cell types that form large stable adhesions. Myosin II dependent contractile forces are thought to facilitate detachment by physically pulling up the rear edge. However, retraction can occur in the absence of myosin II activity in cell types that form small labile adhesions. To investigate the role of contractile force generation in retraction, we performed traction force microscopy during the movement of fish epithelial keratocytes. By correlating changes in local traction stress at the rear with the area retracted, we identified four distinct modes of retraction. "Recoil" retractions are preceded by a rise in local traction stress, while rear edge is temporarily stuck, followed by a sharp drop in traction stress upon detachment. This retraction type was most common in cells generating high average traction stress. In "pull" type retractions local traction stress and area retracted increase concomitantly. This was the predominant type of retraction in keratocytes and was observed mostly in cells generating low average traction stress. "Continuous" type retractions occur without any detectable change in traction stress, and are seen in cells generating low average traction stress. In contrast, to many other cell types, "release" type retractions occur in keratocytes following a decrease in local traction stress. Our identification of distinct modes of retraction suggests that contractile forces may play different roles in detachment that are related to rear adhesion strength. To determine how the regulation of contractility via MLCK or Rho kinase contributes to the mechanics of detachment, inhibitors were used to block or augment these pathways. Modulation of MLCK activity led to the most rapid change in local traction stress suggesting its importance in regulating attachment strength. Surprisingly, Rho kinase was not required for detachment, but was essential for localizing

  19. High-Performance Long-Term-Stable Dopant-Free Perovskite Solar Cells and Additive-Free Organic Solar Cells by Employing Newly Designed Multirole π-Conjugated Polymers.

    PubMed

    Kranthiraja, Kakaraparthi; Gunasekar, Kumarasamy; Kim, Hyunji; Cho, An-Na; Park, Nam-Gyu; Kim, Seonha; Kim, Bumjoon J; Nishikubo, Ryosuke; Saeki, Akinori; Song, Myungkwan; Jin, Sung-Ho

    2017-06-01

    Perovskite solar cells (PSCs) and organic solar cells (OSCs) are promising renewable light-harvesting technologies with high performance, but the utilization of hazardous dopants and high boiling additives is harmful to all forms of life and the environment. Herein, new multirole π-conjugated polymers (P1-P3) are developed via a rational design approach through theoretical hindsight, further successfully subjecting them into dopant-free PSCs as hole-transporting materials and additive-free OSCs as photoactive donors, respectively. Especially, P3-based PSCs and OSCs not only show high power conversion efficiencies of 17.28% and 8.26%, but also display an excellent ambient stability up to 30 d (for PSCs only), owing to their inherent superior optoelectronic properties in their pristine form. Overall, the rational approach promises to support the development of environmentally and economically sustainable PSCs and OSCs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A prospective study of pain reduction and knee dysfunction comparing femoral skeletal traction and splinting in adult trauma patients.

    PubMed

    Bumpass, David B; Ricci, William M; McAndrew, Christopher M; Gardner, Michael J

    2015-02-01

    To determine if distal femoral traction pins result in knee dysfunction in patients with femoral or pelvic fracture, and to determine if skeletal traction relieves pain more effectively than splinting for femoral shaft fractures. Prospective cohort trial. Level I urban trauma center. One hundred twenty adult patients with femoral shaft, acetabular, and unstable pelvic fractures. Patients with femoral shaft fractures were placed into distal femoral skeletal traction or a long-leg splint, based on an attending-specific protocol. Patients with pelvic or acetabular fractures with instability or intraarticular bone fragments were placed into skeletal traction. An initial Lysholm knee survey was administered to assess preinjury knee pain and function; the survey was repeated at 3- and 6-month follow-up visits. Also, a 10-point visual analog scale was used to document pain immediately before, during, and immediately after fracture immobilization with traction or splinting. Thirty-five patients (29%) were immobilized with a long-leg splint, and 85 (71%) were immobilized with a distal femoral traction pin. Eighty-four patients (70%) completed a 6-month follow-up. Lysholm scores decreased by a mean 9.3 points from preinjury baseline to 6 months postinjury in the entire cohort (P < 0.01); no significant differences were found between the splint and traction pin groups. During application of immobilization, visual analog scale pain scores were significantly lower in traction patients as compared with splinted patients (mean, 1.9 points less, P < 0.01). Traction pins caused no infections, neurovascular injuries, or iatrogenic fractures. Distal femoral skeletal traction does not result in detectable knee dysfunction at 6 months after insertion, and results in less pain during and after immobilization than long-leg splinting. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  1. Energy efficiency analysis of two-sided feed scheme of DC traction network with high asymmetry of feeders parameters

    NASA Astrophysics Data System (ADS)

    Abramov, E. Y.; Sopov, V. I.

    2017-10-01

    In a given research using the example of traction network area with high asymmetry of power supply parameters, the sequence of comparative assessment of power losses in DC traction network with parallel and traditional separated operating modes of traction substation feeders was shown. Experimental measurements were carried out under these modes of operation. The calculation data results based on statistic processing showed the power losses decrease in contact network and the increase in feeders. The changes proved to be critical ones and this demonstrates the significance of potential effects when converting traction network areas into parallel feeder operation. An analytical method of calculation the average power losses for different feed schemes of the traction network was developed. On its basis, the dependences of the relative losses were obtained by varying the difference in feeder voltages. The calculation results showed unreasonableness transition to a two-sided feed scheme for the considered traction network area. A larger reduction in the total power loss can be obtained with a smaller difference of the feeders’ resistance and / or a more symmetrical sectioning scheme of contact network.

  2. Age-related differences in the response of the L5-S1 intervertebral disc to spinal traction.

    PubMed

    Mitchell, Ulrike H; Beattie, Paul F; Bowden, Jennifer; Larson, Robert; Wang, Haonan

    2017-10-01

    Lumbar traction is a common treatment for low back pain; however its mechanisms of action are poorly understood. It has been hypothesized that a key effect of lumbar traction is its capacity to influence fluid movement within the intervertebral disc (IVD). To determine differences in the apparent diffusion coefficient (ADC) obtained with lumbar diffusion-weighted imaging (DWI) of the L5-S1 IVD before, and during, the application of lumbar traction. Case series, repeated measures. A static traction load of ∼50% of body-weight was applied to the low back using a novel "MRI-safe" apparatus. DWI of the lumbar spine was performed prior to, and during the application of the traction load. Participants were currently asymptomatic and included a young adult group (n = 18) and a middle-aged group (n = 15). The young adult group had a non-significant 2.2% increase in ADC (mean change = 0.03 × 10 -3  mm 2 /s, SD = 0.24, 95% CI = -0.09, 0.15). The ADC for the middle-aged group significantly increased by 20% (mean change of 0.18 × 10 -3  mm 2 /s, SD = 0.19; 95% CI = 0.07, 0.28; p = 0.003; effect size = 0.95). There was an inverse relationship between the ADC obtained before traction and the percent increase in ADC that was measured during traction. Static traction was associated with an increase in diffusion of water within the L5-S1 IVDs of middle-age individuals, but not in young adults, suggesting age-related differences in the diffusion response. Further study is needed to assess the relationship between these findings and the symptoms of back pain. 4. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Adaptive control system of dump truck traction electric drive

    NASA Astrophysics Data System (ADS)

    Bolshunova, O. M.; Korzhev, A. A.; Kamyshyan, A. M.

    2018-03-01

    The paper describes the operational factors that determine the accident rate of a quarry motor vehicle and assessment of their impact on the choice of the operation mode of the traction drive control system.

  4. The Effects of Shoe Traction and Obstacle Height on Lower Extremity Coordination Dynamics during Walking

    PubMed Central

    Decker, Leslie; Houser, Jeremy J.; Noble, John M.; Karst, Gregory M.; Stergiou, Nicholas

    2009-01-01

    This study aims to investigate the effects of shoe traction and obstacle height on lower extremity relative phase dynamics (analysis of intralimb coordination) during walking to better understand the mechanisms employed to avoid slippage following obstacle clearance. Ten participants walked at a self-selected pace during eight conditions: four obstacle heights (0%, 10%, 20%, and 40% of limb length) while wearing two pairs of shoes (low and high traction). A coordination analysis was used and phasing relationships between lower extremity segments were examined. The results demonstrated that significant behavioral changes were elicited under varied obstacle heights and frictional conditions. Both decreasing shoe traction and increasing obstacle height resulted in a more in-phase relationship between the interacting lower limb segments. The higher the obstacle and the lower the shoe traction, the more unstable the system became. These changes in phasing relationship and variability are indicators of alterations in coordinative behavior, which if pushed further may have lead to falling. PMID:19187929

  5. Demagnetization monitoring and life extending control for permanent magnet-driven traction systems

    NASA Astrophysics Data System (ADS)

    Niu, Gang; Liu, Senyi

    2018-03-01

    This paper presents a novel scheme of demagnetization monitoring and life extending control for traction systems driven by permanent magnet synchronous motors (PMSMs). Firstly, the offline training is carried to evaluate fatigue damage of insulated gate bipolar transistors (IGBTs) under different flux loss based on first-principle modeling. Then an optimal control law can be extracted by turning down the power distribution factor of the demagnetizing PMSM until all damages of IGBTs turn to balance. Next, the similarity-based empirical modeling is employed to online estimate remaining flux of PMSMs, which is used to update the power distribution factor by referring the optimal control law for the health-oriented autonomous control. The proposed strategy can be demonstrated by a case study of traction drive system coupled with dual-PMSMs. Compared with traditional control strategy, the results show that the novel scheme can not only guarantee traction performance but also extend remaining useful life (RUL) of the system after suffering demagnetization fault.

  6. Vehicle non-exhaust emissions from the tyre-road interface - effect of stud properties, traction sanding and resuspension

    NASA Astrophysics Data System (ADS)

    Kupiainen, Kaarle J.; Pirjola, Liisa

    2011-08-01

    In Northern cities respirable street dust emission levels (PM 10) are especially high during spring. The spring time dust has been observed to cause health effects as well as discomfort among citizens. Major sources of the dust are the abrasion products from the pavement and traction sand aggregates that are formed due to the motion of the tyre. We studied the formation of respirable abrasion particles in the tyre-road interface due to tyre studs and traction sanding by a mobile laboratory vehicle Sniffer. The measurements were preformed on a test track, where the influence of varying stud weight and stud number per tyre on PM 10 emissions was studied. Studded tyres resulted in higher emission levels than studless tyres especially with speeds 50 km h -1 and higher; however, by using light weight studs, which approximately halves the weight of studs, or by reducing the number of studs per tyre to half, the emission levels decreased by approximately half. Additionally measurements were done with and without traction sand coverage on the pavement of a public road. After traction sanding the emission levels were not affected by tyre type but by formation and suspension of traction sand related dust from the road surface. The emissions after traction sanding decreased as a function of time as passing vehicles' motion shifted the sand grains away from the areas with most tyre-road contact.

  7. The history of modern spinal traction with particular reference to neural disorders.

    PubMed

    Shterenshis, M V

    1997-03-01

    The last 200 years of the history of spinal traction is described in the present article. The study starts at the end of the 18th century with the works of JA Venel (1789) who tried to apply the Hippocratic idea to modern surgery. Orthopedic specialists of the last century were mostly preoccupied with corsets and the method gained broader popularity when neurologists paid attention to the similar method of suspension. The Russian neurologist Osip Mochutkovsky described suspension as a method for the treatment of tabes dorsalis in an article published in the Russian magazine 'Vratch' in 1883. His works became known in Europe when JM Charcot paid attention to it and published a special short monograph on this subject in 1889. This work was translated into English (1889) and Russian (1890) and the method became popular in the treatment of tabes dorsalis and other neurological diseases. The eminent Russian neurologist VM Bekhterev proposed the combination of body suspension with cervical traction (1893). Some years later Gilles de la Tourette promoted the use of spinal traction in his neurological clinic (1897). Unfortunately neurologists worked without the cooperation of orthopedic specialists. During the first decades of the 20th century suspension was also replaced by traction in neurology. This method was used by both neurologists and orthopedic specialists but in the last decades neurologists lost their interests in it and it found greater use in traumatology and in spinal surgery where it is still in use today.

  8. 21 CFR 882.5960 - Skull tongs for traction.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skull tongs for traction. 882.5960 Section 882.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... cervical spine injury (e.g., fracture or dislocation). The device is caliper shaped with tips that...

  9. Simulation of Trolleybus Traction Induction Drive With Supercapacitor Energy Storage System

    NASA Astrophysics Data System (ADS)

    Brazis, V.; Latkovskis, L.; Grigans, L.

    2010-01-01

    The article considers the possibilities of saving the regenerative braking energy in Škoda 24Tr type trolleybuses by installing the onboard supercapacitor energy storage system (ESS) and improving its performance with automated switching to the autonomous traction mode. Proposed is an ESS control system with constant DC bus voltage in the supercapacitor charging mode and supercapacitor current proportional to the AC drive current in the discharging mode. The authors investigate stability of the trolleybus ESS control system operating together with AC traction drive in various overhead voltage failure modes. The co-simulation of ESS operation was done by Matlab/Simulink AC drive and PSIM ESS continuous models.

  10. Overhead Bryant's Traction Does Not Improve the Success of Closed Reduction or Limit AVN in Developmental Dysplasia of the Hip.

    PubMed

    Sucato, Daniel J; De La Rocha, Adriana; Lau, Karlee; Ramo, Brandon A

    2017-03-01

    Preoperative Bryant's overhead traction before closed reduction (CR) in developmental dysplasia of the hip (DDH) remains controversial and its success in increasing CR rates and reducing avascular necrosis (AVN) rates has not been specifically reported in a large cohort. IRB-approved retrospective study of patients (below 3 y)who were treated with attempted CR for idiopathic DDH from 1980 to 2009. Successful CR was defined as a hip that remained reduced and did not require repeat CR or open reduction. Patients were grouped by age, hip instability [Ortolani positive (reducible) vs. fixed dislocation], and Tonnis classification and rates of successful CR were compared between groups with P<0.05. A total of 342 hips were included with a mean age of 0.9 years (0.2 to 2.8 y) and a mean follow-up of 10.4 years (2.0 to 27.7 y). There were 269 hips with fixed dislocations and 73 Ortolani-positive hips. Traction was used in 276 hips. There was no difference in traction utilization in the 3 age groups (below 1, below 1.5, and below 2 y) for either Ortolani-positive hips (P=0.947) or fixed dislocations (P=0.943). There was no difference in achieving a successful CR comparing traction (60.9%) and no-traction groups (60.6%) (P=1.00). For Ortolani-positive hips, traction did not improve the incidence of a successful CR for any age group: below 1 year: P=0.19; below 1.5 years: P=0.23; and below 2 years: P=0.25. Similarly, fixed dislocation patients had no benefit from traction: below 1 year: P=0.76; below 1.5 years: P=0.82; and below 2 years: P=0.85. Tonnis classification did predict success of CR but had no influence on traction success. There was no difference in the rate of AVN between the traction (18%) and no-traction (8%) groups for all patients (P=0.15). In this retrospective series, preoperative Bryant's traction does not improve the rate of a successful CR for patients with DDH and has no protective effect on the development of AVN of the femoral head. These results

  11. Demonstrating Cell Traction--Using Hens' Egg Vitelline Membrane as Substratum.

    ERIC Educational Resources Information Center

    Downie, Roger

    1987-01-01

    Suggests ways in which hens' egg vitelline membranes can be used to demonstrate cell traction effects. Reviews procedures for using and culturing the membranes and identifies topic areas for student projects. (ML)

  12. Diagnosis of unstable cervical spine injuries: laboratory support for the use of axial traction to diagnose cervical spine instability.

    PubMed

    Kalantar, Babak S; Hipp, John A; Reitman, Charles A; Dreiangel, Niv; Ben-Galim, Peleg

    2010-10-01

    The ability to detect damage to the intervertebral structures is critical in the management of patients after blunt trauma. A practical and inexpensive method to identify severe structural damage not clearly seen on computed tomography would be of benefit. The objective of this study was to assess whether ligamentous injury in the subaxial cervical spine can be reliably detected by analysis of lateral radiographs taken with and without axial traction. Twelve fresh, whole, postrigor-mortis cadavers were used for this study. Lateral cervical spine radiographs were obtained during the application of 0 N, 89 N, and 178 N of axial traction applied to the head. Progressive incremental sectioning of posterior structures was then performed at C4-C5 with traction imaging repeated after each intervention. Intervertebral distraction was analyzed using computer-assisted software. Almost imperceptible intervertebral separation was found when traction was applied to intact spines. In the subaxial cervical spine, the average posterior disc height consistently increased under traction in severely injured spines. The average disc height increase was 14% of the C4 upper endplate width, compared with an average of 2% in the noninjured spines. A change of more than 5% in posterior disc height under traction was above the 95% confidence interval for intact spines, with sensitivity of 83% and specificity of 80%. Applied force of 89 N (20 lb) was sufficient to demonstrate injury. The combination of assessing alignment and distraction under traction increased both the sensitivity and specificity to nearly 100%. This study supports further clinical investigations to determine whether low-level axial traction may be a useful adjunct for detecting unstable subaxial cervical spine injuries in an acute setting.

  13. Investigation of efficiency of electric drive control system of excavator traction mechanism based on feedback on load

    NASA Astrophysics Data System (ADS)

    Kuznetsov, N. K.; Iov, I. A.; Iov, A. A.

    2018-05-01

    The article presents the results of a study of the efficiency of the electric drive control system of the traction mechanism of a dragline based on the use of feedback on load in the traction cable. The investigations were carried out using a refined electromechanical model of the traction mechanism, which took into account not only the elastic elements of the gearbox, the backlashes in it and the changes in the kinematic parameters of the mechanism during operation, but also the mechanical characteristics of the electric drive and the features of its control system. By mathematical modeling of the transient processes of the electromechanical system, it is shown that the introduction of feedback on the load in the elastic element allows one to reduce the dynamic loads in the traction mechanism and to limit the elastic oscillations of the actuating mechanism in comparison with the standard control system. Fixed as a general decrease in the dynamic load of the nodes of traction mechanism in the modes of loading and latching of the bucket, and a decrease the operating time of the mechanism at maximum load. At the same time, undesirable phenomena in the operation of the electric drive were also associated with the increase in the recovery time of the steady-state value of the speed of the actuating mechanism under certain operating conditions, which can lead to a decrease in the reliability of the mechanical part and the productivity of the traction mechanism.

  14. Traction and lubricant film temperature as related to the glass transition temperature and solidification. [using infrared spectroscopy on EHD contacts

    NASA Technical Reports Server (NTRS)

    Lauer, J. L.; Peterkin, M. E.

    1978-01-01

    Does a traction fluid have to be a glass or solid under operating conditions. Infrared spectra on dynamic EHD contacts of several types of fluid were used to determine the surface and oil-film temperatures. Polarized spectral runs were made to study molecular alignment. Static glass transition pressures at appropriate temperatures were between 0.1 and 2.0 GPa, with the traction fluid showing the highest. In the EHD contact region, the traction fluid showed both the highest film temperatures as well as the greatest degree of molecular alignment. A plot of the difference between the film and surface temperatures vs shear rate resulted in a master plot valid for all the fluids. From this work, the authors propose a model of 'fluid' traction, where friction between parallel rough molecules provides the traction.

  15. Modification of the SHABERTH bearing code to incorporate RP-1 and a discussion of the traction model

    NASA Technical Reports Server (NTRS)

    Woods, Claudia M.

    1990-01-01

    Recently developed traction data for Rocket Propellant 1 (RP-1), a hydrocarbon fuel of the kerosene family, was used to develop the parameters needed by the bearing code SHABERTH in order to include RP-1 as a lubricant choice. The procedure for inputting data for a new lubricant choice is reviewed, and the theoretical fluid traction model is discussed. Comparisons are made between experimental traction data and those predicted by SHABERTH for RP-1. All data needed to modify SHABERTH for use with RP-1 as a lubricant are specified.

  16. [The application of delayed skin grafting combined traction in severe joint cicatricial contracture].

    PubMed

    Xu, Zihan; Zhang, Zhenxin; Wang, Benfeng; Sun, Yaowen; Guo, Yadong; Gao, Wenjie; Qin, Gaoping

    2014-11-01

    To investigate the effect of delayed skin grafting combined traction in severe joint cicatricial contracture. At the first stage, the joint cicatricial contracture was released completely with protection of vessels, nerves and tendons. The wound was covered with allogenetic skin or biomaterials. After skin traction for 7-14 days, the joint could reach the extension position. Then the skin graft was performed on the wound. 25 cases were treated from Mar. 2000 to May. 2013. Primary healing was achieved at the second stage in all the cases. The skin graft had a satisfactory color and elasticity. Joint function was normal. All the patients were followed up for 3 months to 11 years with no hypertrophic scar and contraction relapse, except for one case who didn' t have enough active exercise on shoulder joint. Delayed skin grafting combined traction can effectively increase the skin graft survival rate and improve the joint function recovery.

  17. Traction studies of piston ring wear using an external radiometric method with proton activation

    NASA Astrophysics Data System (ADS)

    Scharf, Waldemar; Niewczas, Andrzej

    1987-04-01

    A method and results are presented of traction studies of piston ring wear in a Polski Fiat 126p passenger car and Star 200 lorry. The rings sliding surface was activated with a beam of 9.6-MeV protons and the measurements were made using a collimated scintillation detector placed outside the engine, i.e. without interfering with the engine's operation. The cars were run under varying traction conditions, their mileages having ranged between 7000 and 12000 km. In stable wear conditions on the road the piston ring wear for the passenger car and the lorry was {0.28%}/{100} km and {0.045%}/{100} km, respectively. The method was found to be particularly suitable for traction studies because it is simple and cheap. It can be employed as early as after the first 100 km of the car mileage.

  18. Concept for a Differential Lock and Traction Control Model in Automobiles

    NASA Astrophysics Data System (ADS)

    Shukul, A. K.; Hansra, S. K.

    2014-01-01

    The automobile is a complex integration of electronics and mechanical components. One of the major components is the differential which is limited due to its shortcomings. The paper proposes a concept of a cost effective differential lock and traction for passenger cars to sports utility vehicles alike, employing a parallel braking mechanism coming into action based on the relative speeds of the wheels driven by the differential. The paper highlights the employment of minimum number of components unlike the already existing systems. The system was designed numerically for the traction control and differential lock for the world's cheapest car. The paper manages to come up with all the system parameters and component costing making it a cost effective system.

  19. PREDICTIVE FACTORS OF SURGICAL OUTCOMES IN VITRECTOMY FOR MYOPIC TRACTION MACULOPATHY.

    PubMed

    Hattori, Kyoko; Kataoka, Keiko; Takeuchi, Jun; Ito, Yasuki; Terasaki, Hiroko

    2017-11-07

    To assess predictive factors and surgical outcomes for myopic traction maculopathy. This retrospective observational case study enrolled 73 patients who underwent vitrectomy for myopic traction maculopathy. The 79 eyes obtained from our study sample were divided into 4 types: retinoschisis, lamellar macular hole (lamellar MH), foveal retinal detachment (FRD), and FRD + lamellar MH, or into 2 types according to the presence of FRD preoperatively. Dependent variables of interest were age, sex, pre- and postoperative best-corrected visual acuity (BCVA) at 6 months, and axial length. All the four types showed moderately strong-to-strong positive correlations with pre- and postoperative BCVA (retinochisisi: r = 0.61; lamellar MH: r = 0.62; FRD: r = 0.51; FRD + lamellar MH; r = 0.83). Preoperative BCVA was associated with postoperative BCVA (P < 0.0001), but age, axial length, and the types of preoperative foveal status were not. Eyes with FRD had significantly worse pre- and postoperative BCVA than eyes without FRD (P = 0.036 and P = 0.046, respectively). Postoperative full-thickness macular holes developed in 5.1% of cases and in all types but retinoschisis. Preoperative visual acuity and the presence of FRD should be considered for surgical indication of myopic traction maculopathy.

  20. Rapid, efficient charging of lead-acid and nickel-zinc traction cells

    NASA Technical Reports Server (NTRS)

    Smithrick, J. J.

    1978-01-01

    Lead-acid and nickel-zinc traction cells were rapidly and efficiently charged using a high rate tapered direct current (HRTDC) charge method which could possibly be used for on-the-road service recharge of electric vehicles. The HRTDC method takes advantage of initial high cell charge acceptance and uses cell gassing rate and temperature as an indicator of charging efficiency. On the average, in these preliminary tests, 300 amp-hour nickel-zinc traction cells were given a HRTDC (initial current 500 amps, final current 100 amps) to 78 percent of rated amp-hour capacity within 53 minutes at an amp-hour efficiency of 92 percent and an energy efficiency of 52 percent. Three hundred amp-hour lead-acid traction cells were charged to 69 percent of rated amp-hour capacity within 46 minutes at an amp-hour efficiency of 91 percent with an energy efficiency of 64 percent. In order to find ways to further decrease the recharge times, the effect of periodically (0 to 400 Hz) pulse discharging cells during a constant current charging process (94% duty cycle) was investigated. Preliminary data indicate no significant effect of this type of pulse discharging during charge on charge acceptance of lead-acid or nickel-zinc cells.

  1. The Effect of Skin Traction on Preoperative Pain and Need for Analgesics in Patients With Intertrochanteric Fractures: A Randomized Clinical Trial

    PubMed Central

    Manafi Rasi, Alireza; Amoozadeh, Farzad; Khani, Salim; Kamrani Rad, Amin; Sazegar, Ali

    2015-01-01

    Background: Preoperative skin traction is applied for many patients with hip fracture. However, the efficacy of this modality in pain relief is controversial. Objectives: The aim of the current study was to investigate the effects of skin traction on pain in patients with intertrochanteric fractures. Patients and Methods: A total of 40 patients contributed in this randomized clinical trial. Patients were randomly allocated into two equal groups: the skin traction (3 kg) and control groups. The severity of pain was recorded at admission and 30 minutes, one, six, 12, and 24 hours after skin traction application utilizing a Visual Analogue Scale (VAS). In addition, the number of requests for analgesics was recorded. Finally, the mean severity of pain in each measurement and the mean number of analgesic requests were compared between the two groups. Results: The severity of pain was significantly decreased in skin traction group only at the end of the first day after traction application (2.7 ± 0.8 vs. 3.3 ± 0.9; P = 0.042), while there was no significant difference between the two groups in other pain measurements. The number of requests for analgesics was the same between the two groups. Conclusions: Although skin traction had no effect on analgesic consumption, it significantly decreased the pain at the end of the first day. The application of skin traction in patients with intertrochanteric fractures is recommended. PMID:26401491

  2. Traction drive automatic transmission for gas turbine engine driveline

    DOEpatents

    Carriere, Donald L.

    1984-01-01

    A transaxle driveline for a wheeled vehicle has a high speed turbine engine and a torque splitting gearset that includes a traction drive unit and a torque converter on a common axis transversely arranged with respect to the longitudinal centerline of the vehicle. The drive wheels of the vehicle are mounted on a shaft parallel to the turbine shaft and carry a final drive gearset for driving the axle shafts. A second embodiment of the final drive gearing produces an overdrive ratio between the output of the first gearset and the axle shafts. A continuously variable range of speed ratios is produced by varying the position of the drive rollers of the traction unit. After starting the vehicle from rest, the transmission is set for operation in the high speed range by engaging a first lockup clutch that joins the torque converter impeller to the turbine for operation as a hydraulic coupling.

  3. Comparison between effectiveness of Mechanical and Manual Traction combined with mobilization and exercise therapy in Patients with Cervical Radiculopathy.

    PubMed

    Bukhari, Syed Rehan Iftikhar; Shakil-Ur-Rehman, Syed; Ahmad, Shakeel; Naeem, Aamer

    2016-01-01

    Cervical radiculopathy is a common neuro-musculo-skeletal disorder causing pain and disability. Traction is part of the evidence based manual physical therapy management due to its mechanical nature, type of traction and parameters related to its applicability and are still to be explored more through research. Our objective was to determine the Effects of Mechanical versus Manual Traction in Manual Physical Therapy combined with segmental mobilization and exercise therapy in the physical therapy management of Patients with Cervical Radiculopathy. This randomized control trial was conducted at department of physical therapy and rehabilitation, Rathore Hospital Faisalabad, from February to July 2015. Inclusion criteria were both male and female patients with evident symptoms of cervical spine radiculopathy and age ranged between 20-70 years. The exclusion criteria were Patients with history of trauma, neck pain without radiculopathy, aged less than 20 and more than 70. A total of 72 patients with cervical radiculopathy were screened out as per the inclusion criteria, 42 patients were randomly selected and placed into two groups by toss and trial method, and only 36 patients completed the study, while 6 dropped out. The mechanical traction was applied in group A and manual traction in group B along with common intervention of segmental mobilization and exercise therapy in both groups for 6 weeks. The patient's outcomes were assessed by self reported NPRS and NDI at the baseline and after completion of 06 weeks exercise program at 3 days per week. The data was analyzed through SPSS version-21, and paired T test was applied at 95% level significance to determine the statistical deference between two groups. Clinically the group of patients treated with mechanical traction managed pain (mean pre 6.26, mean post 1.43), and disability (mean pre 24.43 and mean post 7.26) more effectively as compared with the group of patients treated with manual traction (Pain mean pre 6

  4. Group traction drive as means to increase energy efficiency of lokomotives of open-pit transport

    NASA Astrophysics Data System (ADS)

    Antipin, D. Ya; Izmerov, O. V.; Bishutin, S. G.; Kobishchanov, V. V.

    2017-10-01

    Questions of possible use of a group drive for locomotives of an open-pit transport are considered. The possibility of a significant reduction of traction costs in the case of a combination of a group traction drive with devices for the non-inertial regulation of the coefficient of friction between the wheel and the rail has been shown, and new patentable solutions have been proposed.

  5. Digital Model of Railway Electric Traction Lines

    NASA Astrophysics Data System (ADS)

    Garg, Rachana; Mahajan, Priya; Kumar, Parmod

    2017-08-01

    The characteristic impedance and propagation constant define the behavior of signal propagation over the transmission lines. The digital model for railway traction lines which includes railway tracks is developed, using curve fitting technique in MATLAB. The sensitivity of this model has been computed with respect to frequency. The digital sensitivity values are compared with the values of analog sensitivity. The developed model is useful for digital protection, integrated operation, control and planning of the system.

  6. Locomotive dynamic performance under traction/braking conditions considering effect of gear transmissions

    NASA Astrophysics Data System (ADS)

    Chen, Zaigang; Zhai, Wanming; Wang, Kaiyun

    2018-07-01

    Traction or braking operations are usually applied to trains or locomotives for acceleration, speed adjustment, and stopping. During these operations, gear transmission equipment plays a very significant role in the delivery of traction or electrical braking power. Failures of the gear transmissions are likely to cause power loses and even threaten the operation safety of the train. Its dynamic performance is closely related to the normal operation and service safety of the entire train, especially under some emergency braking conditions. In this paper, a locomotive-track coupled vertical-longitudinal dynamics model is employed with considering the dynamic action from the gear transmissions. This dynamics model enables the detailed analysis and more practical simulation on the characteristics of power transmission path, namely motor-gear transmission-wheelset-longitudinal motion of locomotive, especially for traction or braking conditions. Multi-excitation sources, such as time-varying mesh stiffness and nonlinear wheel-rail contact excitations, are considered in this study. This dynamics model is then validated by comparing the simulated results with the experimental test results under braking conditions. The calculated results indicate that involvement of gear transmission could reveal the load reduction of the wheelset due to transmitted forces. Vibrations of the wheelset and the motor are dominated by variation of the gear dynamic mesh forces in the low speed range and by rail geometric irregularity in the higher speed range. Rail vertical geometric irregularity could also cause wheelset longitudinal vibrations, and do modulations to the gear dynamic mesh forces. Besides, the hauling weight has little effect on the locomotive vibrations and the dynamic mesh forces of the gear transmissions for both traction and braking conditions under the same running speed.

  7. A hemidesmosomal protein regulates actin dynamics and traction forces in motile keratinocytes

    PubMed Central

    Hiroyasu, Sho; Colburn, Zachary T.; Jones, Jonathan C. R.

    2016-01-01

    During wound healing of the skin, keratinocytes disassemble hemidesmosomes and reorganize their actin cytoskeletons in order to exert traction forces on and move directionally over the dermis. Nonetheless, the transmembrane hemidesmosome component collagen XVII (ColXVII) is found in actin-rich lamella, situated behind the lamellipodium. A set of actin bundles, along which ColXVII colocalizes with actinin4, is present at each lamella. Knockdown of either ColXVII or actinin4 not only inhibits directed migration of keratinocytes but also relieves constraints on actin bundle retrograde movement at the site of lamella, such that actin bundle movement is enhanced more than 5-fold. Moreover, whereas control keratinocytes move in a stepwise fashion over a substrate by generating alternating traction forces, of up to 1.4 kPa, at each flank of the lamellipodium, ColXVII knockdown keratinocytes fail to do so. In summary, our data indicate that ColXVII-actinin4 complexes at the lamella of a moving keratinocyte regulate actin dynamics, thereby determining the direction of cell movement.—Hiroyasu, S., Colburn, Z. T., Jones, J. C. R. A hemidesmosomal protein regulates actin dynamics and traction forces in motile keratinocytes. PMID:26936359

  8. Case studies on local orthodontic traction by minis-implants before implant rehabilitation

    PubMed Central

    Shen, Pei; Xu, Wei-Feng; Ma, Zhi-Gui; Zhang, Shan-Yong; Zhang, Ying

    2015-01-01

    Objective: Dentition defect with malocclusion is a common occurrence in the clinical work. To restore proper occlusion, preprosthetic corrections of these malposed teeth are often indispensible. The use of orthodontic mini-implants as temporary anchorage devices provides a plausible treatment for those patients with local problems. The aim of this study was to present two cases using local orthodontic traction in conjunction with mini-implants to provide necessary conditions for implant rehabilitation in three dimensional space. Clinical consideration: Two cases who had dentition defect with malocclusion were included in the present study. As both of them rejected crown reduction or orthodontics treatment, local orthodontic traction by mini-implants was used to restore normal space for implant rehabilitation in three dimensions. Careful mechanics analysis and personalized mechanical device were under consideration. The results showed that the biological responses of the corrected teeth and the surrounding bony structures appeared normal and acceptable. Moreover the patients achieved an ideal local occlusion with a short treatment time. Conclusion: In conclusion local orthodontic traction by mini-implants was a less-invasive and short-term method with favorable effects and less necessary occlusal adjustments. PMID:26221389

  9. Traction force and tension fluctuations in growing axons

    NASA Astrophysics Data System (ADS)

    Urbach, Jeffrey; Polackwich, Jamie; Koch, Daniel; McAllister, Ryan; Geller, Herbert

    Actively generated mechanical forces play a central role in axon growth and guidance during nervous system development. We describe the dynamics of traction stresses from growth cones of actively advancing axons from postnatal rat DRG neurons. By tracking the movement of the growth cone and analyzing the traction stresses in a co-moving reference frame, we show that there is a clear and consistent average stress field underlying the complex spatial stresses present at any one time. The average stress field has strong maxima on the sides of the growth cone, directed inward toward the growth cone neck. This pattern represents a Contractile stress contained within the growth cone, and a net force that is balanced by the axon tension. In addition, using high time-resolution measurements, we show that the stress field is composed of fluctuating local stress peaks, with a population of peaks whose lifetime distribution follows an exponential decay, and a small number of very long-lived peaks. We also find that the tension appears to vary randomly over short time scales, roughly consistent with the lifetime of the stress peaks, suggesting that the tension fluctuations originate from stochastic adhesion dynamics.

  10. Biomechanical analysis of combining head-down tilt traction with vibration for different grades of degeneration of the lumbar spine.

    PubMed

    Wang, Sicong; Wang, Lizhen; Wang, Yawei; Du, Chengfei; Zhang, Ming; Fan, Yubo

    2017-01-01

    In recent years, a combination of traction and vibration therapy is usually used to alleviate low back pain (LBP) in clinical settings. Combining head-down tilt (HDT) traction with vibration was demonstrated to be efficacious for LBP patients in our previous study. However, the biomechanics of the lumbar spine during this combined treatment is not well known and need quantitative analysis. In addition, LBP patients have different grades of degeneration of the lumbar spinal structure, which are often age related. Selecting a suitable rehabilitation therapy for different age groups of patients has been challenging. Therefore, a finite element (FE) model of the L1-L5 lumbar spine and a vibration dynamic model are developed in this study in order to investigate the biomechanical effects of the combination of HDT traction and vibration therapy on the age-related degeneration of the lumbar spine. The decrease of intradiscal pressure is more effective when vibration is combined with traction therapy. Moreover, the stresses on the discs are lower in the "traction+vibration" mode than the "traction-only" mode. The stress concentration at the posterior part of nucleus is mitigated after the vibration is combined. The disc deformations especially posterior disc radial retraction is improved in the "traction+vibration" mode. These beneficial effects of this therapy could help decompress the discs and spinal nerves and therefore relieve LBP. Simultaneously, patients with grade 1 degeneration (approximately 41-50 years old) are able to achieve better results compared with other age groups. This study could be used to provide a more effective LBP rehabilitation therapy. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Degradation-mediated cellular traction directs stem cell fate in covalently crosslinked three-dimensional hydrogels

    NASA Astrophysics Data System (ADS)

    Khetan, Sudhir; Guvendiren, Murat; Legant, Wesley R.; Cohen, Daniel M.; Chen, Christopher S.; Burdick, Jason A.

    2013-05-01

    Although cell-matrix adhesive interactions are known to regulate stem cell differentiation, the underlying mechanisms, in particular for direct three-dimensional encapsulation within hydrogels, are poorly understood. Here, we demonstrate that in covalently crosslinked hyaluronic acid (HA) hydrogels, the differentiation of human mesenchymal stem cells (hMSCs) is directed by the generation of degradation-mediated cellular traction, independently of cell morphology or matrix mechanics. hMSCs within HA hydrogels of equivalent elastic moduli that permit (restrict) cell-mediated degradation exhibited high (low) degrees of cell spreading and high (low) tractions, and favoured osteogenesis (adipogenesis). Moreover, switching the permissive hydrogel to a restrictive state through delayed secondary crosslinking reduced further hydrogel degradation, suppressed traction, and caused a switch from osteogenesis to adipogenesis in the absence of changes to the extended cellular morphology. Furthermore, inhibiting tension-mediated signalling in the permissive environment mirrored the effects of delayed secondary crosslinking, whereas upregulating tension induced osteogenesis even in the restrictive environment.

  12. Thrombin-induced contraction in alveolar epithelial cells probed by traction microscopy.

    PubMed

    Gavara, Núria; Sunyer, Raimon; Roca-Cusachs, Pere; Farré, Ramon; Rotger, Mar; Navajas, Daniel

    2006-08-01

    Contractile tension of alveolar epithelial cells plays a major role in the force balance that regulates the structural integrity of the alveolar barrier. The aim of this work was to study thrombin-induced contractile forces of alveolar epithelial cells. A549 alveolar epithelial cells were challenged with thrombin, and time course of contractile forces was measured by traction microscopy. The cells exhibited basal contraction with total force magnitude 55.0 +/- 12.0 nN (mean +/- SE, n = 12). Traction forces were exerted predominantly at the cell periphery and pointed to the cell center. Thrombin (1 U/ml) induced a fast and sustained 2.5-fold increase in traction forces, which maintained peripheral and centripetal distribution. Actin fluorescent staining revealed F-actin polymerization and enhancement of peripheral actin rim. Disruption of actin cytoskeleton with cytochalasin D (5 microM, 30 min) and inhibition of myosin light chain kinase with ML-7 (10 microM, 30 min) and Rho kinase with Y-27632 (10 microM, 30 min) markedly depressed basal contractile tone and abolished thrombin-induced cell contraction. Therefore, the contractile response of alveolar epithelial cells to the inflammatory agonist thrombin was mediated by actin cytoskeleton remodeling and actomyosin activation through myosin light chain kinase and Rho kinase signaling pathways. Thrombin-induced contractile tension might further impair alveolar epithelial barrier integrity in the injured lung.

  13. Modulating DNA configuration by interfacial traction: an elastic rod model to characterize DNA folding and unfolding.

    PubMed

    Huang, Zaixing

    2011-01-01

    As a continuum model of DNA, a thin elastic rod subjected to interfacial interactions is used to investigate the equilibrium configuration of DNA in intracellular solution. The interfacial traction between the rod and the solution environment is derived in detail. Kirchhoff's theory of elastic rods is used to analyze the equilibrium configuration of a DNA segment under the action of the interfacial traction. The influences of the interfacial energy factor and bending stiffness on the toroidal spool formation of the DNA segment are discussed. The results show that the equilibrium configuration of DNA is mainly determined by competition between the interfacial energy and elastic strain energy of the DNA itself, and the interfacial traction is one of the forces that drives DNA folding and unfolding.

  14. Animal Traction. Appropriate Technologies for Development. Manual M-12.

    ERIC Educational Resources Information Center

    Watson, Peter R.

    This manual is designed for use by Peace Corps volunteers and agricultural extension personnel working in animal traction development programs. While some of the information contained in the manual is specific to the extension of animal-powered agriculture in Africa, the principles covered are generally applicable wherever the method is being used…

  15. Suicidal ideation among rural immigrant daughters-in-law with multi-roles as females, farmers and immigrants in China.

    PubMed

    Qin, Qirong; Jin, Yu; Zhan, Shengwei; Yu, Xiaodong; Huang, Fen

    2016-07-01

    Suicide is a major public health issue in China, and suicidal ideation is an important step in the suicidal process. The purpose of this study was to understand the prevalence and correlates of suicidal ideation among rural immigrant daughters-in-law with multi-role of female, farmer and immigrant in China. A total of 939 participants including 474 local daughters-in-law and 465 immigrant daughters-in-law were surveyed using the self-rating questionnaire. Demographic characteristics, depression, anxiety, impulsivity and suicidal ideation were assessed. Results indicated that the lifetime prevalence of suicidal ideation among rural immigrant daughters-in-law was 9.68%. Physical disability, domestic violence and negative events demonstrated statistical significance by suicidal ideation (p < .05), and participants with suicidal ideation had higher scores of depression, anxiety and impulsiveness in the univariate analysis. Multivariate logistic regression showed that physical disability (OR = 7.43, 95%CI: 2.84-19.46), domestic violence (OR = 2.65, 95%CI: 1.02-6.88), depression (OR = 1.07, 95%CI: 1.01-1.12), impulsiveness (OR = 1.04, 95%CI: 1.01-1.08) and motor impulsiveness (OR = 1.07, 95%CI: 1.01-1.14) were significantly associated with suicidal ideation. Suicidal ideation is an issue that can't be ignored among rural immigrant daughters-in-law. And the findings should be considered for the intervention of the suicide among the rural immigrant daughters-in-law.

  16. Creep force modelling for rail traction vehicles based on the Fastsim algorithm

    NASA Astrophysics Data System (ADS)

    Spiryagin, Maksym; Polach, Oldrich; Cole, Colin

    2013-11-01

    The evaluation of creep forces is a complex task and their calculation is a time-consuming process for multibody simulation (MBS). A methodology of creep forces modelling at large traction creepages has been proposed by Polach [Creep forces in simulations of traction vehicles running on adhesion limit. Wear. 2005;258:992-1000; Influence of locomotive tractive effort on the forces between wheel and rail. Veh Syst Dyn. 2001(Suppl);35:7-22] adapting his previously published algorithm [Polach O. A fast wheel-rail forces calculation computer code. Veh Syst Dyn. 1999(Suppl);33:728-739]. The most common method for creep force modelling used by software packages for MBS of running dynamics is the Fastsim algorithm by Kalker [A fast algorithm for the simplified theory of rolling contact. Veh Syst Dyn. 1982;11:1-13]. However, the Fastsim code has some limitations which do not allow modelling the creep force - creep characteristic in agreement with measurements for locomotives and other high-power traction vehicles, mainly for large traction creep at low-adhesion conditions. This paper describes a newly developed methodology based on a variable contact flexibility increasing with the ratio of the slip area to the area of adhesion. This variable contact flexibility is introduced in a modification of Kalker's code Fastsim by replacing the constant Kalker's reduction factor, widely used in MBS, by a variable reduction factor together with a slip-velocity-dependent friction coefficient decreasing with increasing global creepage. The proposed methodology is presented in this work and compared with measurements for different locomotives. The modification allows use of the well recognised Fastsim code for simulation of creep forces at large creepages in agreement with measurements without modifying the proven modelling methodology at small creepages.

  17. Model-based traction force microscopy reveals differential tension in cellular actin bundles.

    PubMed

    Soiné, Jérôme R D; Brand, Christoph A; Stricker, Jonathan; Oakes, Patrick W; Gardel, Margaret L; Schwarz, Ulrich S

    2015-03-01

    Adherent cells use forces at the cell-substrate interface to sense and respond to the physical properties of their environment. These cell forces can be measured with traction force microscopy which inverts the equations of elasticity theory to calculate them from the deformations of soft polymer substrates. We introduce a new type of traction force microscopy that in contrast to traditional methods uses additional image data for cytoskeleton and adhesion structures and a biophysical model to improve the robustness of the inverse procedure and abolishes the need for regularization. We use this method to demonstrate that ventral stress fibers of U2OS-cells are typically under higher mechanical tension than dorsal stress fibers or transverse arcs.

  18. Model-based Traction Force Microscopy Reveals Differential Tension in Cellular Actin Bundles

    PubMed Central

    Soiné, Jérôme R. D.; Brand, Christoph A.; Stricker, Jonathan; Oakes, Patrick W.; Gardel, Margaret L.; Schwarz, Ulrich S.

    2015-01-01

    Adherent cells use forces at the cell-substrate interface to sense and respond to the physical properties of their environment. These cell forces can be measured with traction force microscopy which inverts the equations of elasticity theory to calculate them from the deformations of soft polymer substrates. We introduce a new type of traction force microscopy that in contrast to traditional methods uses additional image data for cytoskeleton and adhesion structures and a biophysical model to improve the robustness of the inverse procedure and abolishes the need for regularization. We use this method to demonstrate that ventral stress fibers of U2OS-cells are typically under higher mechanical tension than dorsal stress fibers or transverse arcs. PMID:25748431

  19. Influences on lifetime of wire ropes in traction lifts

    NASA Astrophysics Data System (ADS)

    Vogel, W.

    2016-05-01

    Traction lifts are complex systems with rotating and translating moving masses, springs and dampers and several system inputs from the lifts and the users. The wire ropes are essential mechanical elements. The mechanical properties of the ropes in use depend on the rope construction, the load situation, nonlinearities and the lift dimensions. The mechanical properties are important for the proper use in lifts and the ride quality. But first of all the wire ropes (for all other suspension means as well) have to satisfy the safety relevant requirements sufficient lifetime, reliable determination of discard and sufficient and limited traction capacity. The lifetime of the wire ropes better the number of trips until rope discard depends on a lot of parameters of the rope and the rope application eg use of plastic deflection sheaves and reverse bending layouts. New challenges for rope lifetime are resulting from the more or less open D/d-ratio limits possible by certificates concerning the examination of conformity by notified bodies. This paper will highlight the basics of wire rope technology, the endurance and lifetime of wire ropes running over sheaves, and the different influences from the ropes and more and more important from the lift application parameters. Very often underestimated are the influences of transport, storage, installation and maintenance. With this background we will lead over to the calculation methods of wire rope lifetime considering the actual findings of wire rope endurance research. We'll show in this paper new and innovative facts as the influence of rope length and size factor in the lifetime formular, the reduction of lifetime caused by traction grooves, the new model for the calculation in reverse bending operations and the statistically firmed possibilities for machine roomless lifts (MRL) under very small bending conditions.

  20. Treatment of Extreme Tuberculous Kyphosis Using Spinal Osteotomy and Halo-Pelvic Traction: A Case Report.

    PubMed

    Yu, Bin; Zhu, Ke; Zhao, Deng; Wang, Fei; Liang, Yijian

    2016-02-01

    A case report of treatment of extreme tuberculous kyphosis using spinal osteotomy and halopelvic traction. The aim of this study was to describe the process and outcome of treatment of a case with extreme tuberculous kyphosis using spine osteotomy and halo-pelvic traction. Spinal tuberculosis causes destruction, deformity, and paraplegia. Long-standing kyphosis may progress with growth in children, and produces respiratory insufficiency, and neurologic deficit. Surgery may help to prevent or reverse the neurological deterioration, while improving pulmonary function in cases with significant spinal deformity. Review of records and radiographs. A 24-year-old female with tuberculous angular kyphosis presented with bilateral lower extremities paresis and dyspnea. The vertebral bodies from T3 to T9 were severely destructed, with a Cobb's angle of 180°on radiographs. The total duration of distraction using halopelvic apparatus kept 10 months. During the duration of traction, the patient underwent a posterior release surgery because flexibility of the kyphosis was not sufficient. Pedicle subtraction osteotomy and pedicle screw fixation were performed to achieve final correction when the Cobb's angle decreased to about 80°. After the whole treatment of halopelvic traction and spine ostetomy, the patient's height increased nearly 30 cm, whereas the angular kyphosis was corrected to a Cobb's angle of 30°. The patient had no complication and neurological deterioration during the treatment. Correction angle and good sagittal balance were well maintained in the duration of 2 years' follow-up. The halo-pelvic apparatus produces high corrective forces applied over a long period, and it provides a slow and safe correction of deformity. In cases of extreme kyphotic deformity, halopelvic traction is an appropriate technique, while avoiding many serious complications from a rapid, one-stage correction. N/A.

  1. Lateral traction of laminar flow between sliding pair with heterogeneous slip/no-slip surface

    NASA Astrophysics Data System (ADS)

    Wu, Zhenpeng; Zeng, Liangcai; Chen, Xiaolan; Chen, Keying; Ding, Xianzhong

    2017-11-01

    The problem of shaft axial motion which significantly affects the lubrication performance has been a common phenomenon in journal bearing systems. The existing work involved in the solution of shaft axial motion is also very rare. In this study, we choose to examine the flow between sliding pair in which regard we present a unique heterogeneous surface consisting of a slip zone and a no-slip zone. The results reveal the following points: 1) By appropriately arranging the slip zone to change the angle between the borderline and the moving direction of the upper plate, it is possible to control the direction of the lateral traction in which the liquid film acts on the upper plate. 2) Exponent of the power function of the borderline and aspect ratio of the computational domain are large or small are not conducive to increasing the effect of lateral traction. For the object of this study, the final results of the optimization are shown that the lateral traction can account for 20% of the resistance.

  2. Two-Stage Thoracoscopic Repair of Long-Gap Esophageal Atresia Using Internal Traction Is Safe and Feasible.

    PubMed

    Tainaka, Takahisa; Uchida, Hiroo; Tanano, Akihide; Shirota, Chiyoe; Hinoki, Akinari; Murase, Naruhiko; Yokota, Kazuki; Oshima, Kazuo; Shirotsuki, Ryo; Chiba, Kosuke; Amano, Hizuru; Kawashima, Hiroshi; Tanaka, Yujiro

    2017-01-01

    The treatment of long-gap esophageal atresia remains an issue for pediatric surgeons. Many techniques for treating long-gap esophageal atresia have been proposed, but the optimal method has not been established. The thoracoscopic esophageal elongation technique has recently been developed. We previously reported a case in which two-stage thoracoscopic repair was performed using internal esophageal traction without esophageal tearing, and we retrospectively reviewed the outcomes of this procedure in this study. Five patients underwent thoracoscopic treatment involving internal esophageal traction for esophageal atresia involving a long gap or vascular ring over a 5-year period. Between November 2010 and November 2015, 5 patients were treated with thoracoscopic traction. All of these patients successfully underwent thoracoscopic-delayed primary anastomosis. Conversion to open thoracotomy was not required in any case. The postoperative complications experienced by the patients included minor anastomotic leakage in 2 cases, anastomotic stenosis in 1 case, gastroesophageal reflux (GER) in 4 cases, and a hiatal hernia in 1 case. None of the patients died. Two-stage thoracoscopic repair for esophageal atresia involving a long gap or vascular ring is a safe and feasible procedure; however, we must develop methods for treating minor anastomotic complications and GER due to esophageal traction in future.

  3. An overview of the development of lead/acid traction batteries for electric vehicles in India

    NASA Astrophysics Data System (ADS)

    Sivaramaiah, G.; Subramanian, V. R.

    Electric vehicles (EVs) made an entry into the Indian scene quite recently in the area of passenger transportation, milk floats and other similar applications. The industrial EV market, with various models of fork-lift trucks and platform trucks already in wide use all over India, is a better understood application of EV batteries. The lead/acid traction batteries available in India are not of high-energy density. The best available indigenous lead/acid traction battery has an energy density ( C/5 rate) of 30 W h kg -1 as against 39 W h kg -1 available abroad. This paper reviews the developmental efforts relating to lead/acid traction batteries for electric vehicle applications in India, such as prototype road vehicles, commercial vehicles, rail cars, and locomotives. Due to the need for environmental protection and recognition of exhaustible, finite supplies of petroleum fuel, the Indian government is presently taking active interest in EV projects.

  4. Some effects of grooved runway configurations on aircraft tire braking traction under flooded runway conditions

    NASA Technical Reports Server (NTRS)

    Byrdsong, T. A.

    1973-01-01

    An experimental investigation was conducted to study the effect of grooved runway configurations on aircraft tire braking traction on flooded runway surfaces. The investigation was performed, utilizing size 49 x 17, type VII, aircraft tires with an inflation pressure of 170 lb per square inch at ground speeds up to approximately 120 knots. The results of this investigation indicate that when the runway is flooded, grooved surfaces provide better braking traction than an ungrooved surface and, in general, the level of braking traction was found to improve as the tire bearing pressure was increased because of an increase in the groove area of either the surface or the tire tread. Rounding the groove edges tended to degrade the tire braking capability from that developed on the same groove configuration with sharp edges. Results also indicate that braking friction coefficients for the test tires and runway surfaces decreased as ground speed was increased because of the hydroplaning effects.

  5. Pulse charging of lead-acid traction cells

    NASA Technical Reports Server (NTRS)

    Smithrick, J. J.

    1980-01-01

    Pulse charging, as a method of rapidly and efficiently charging 300 amp-hour lead-acid traction cells for an electric vehicle application was investigated. A wide range of charge pulse current square waveforms were investigated and the results were compared to constant current charging at the time averaged pulse current values. Representative pulse current waveforms were: (1) positive waveform-peak charge pulse current of 300 amperes (amps), discharge pulse-current of zero amps, and a duty cycle of about 50%; (2) Romanov waveform-peak charge pulse current of 300 amps, peak discharge pulse current of 15 amps, and a duty of 50%; and (3) McCulloch waveform peak charge pulse current of 193 amps, peak discharge pulse current of about 575 amps, and a duty cycle of 94%. Experimental results indicate that on the basis of amp-hour efficiency, pulse charging offered no significant advantage as a method of rapidly charging 300 amp-hour lead-acid traction cells when compared to constant current charging at the time average pulse current value. There were, however, some disadvantages of pulse charging in particular a decrease in charge amp-hour and energy efficiencies and an increase in cell electrolyte temperature. The constant current charge method resulted in the best energy efficiency with no significant sacrifice of charge time or amp-hour output. Whether or not pulse charging offers an advantage over constant current charging with regard to the cell charge/discharge cycle life is unknown at this time.

  6. Identifying traction-separation behavior of self-adhesive polymeric films from in situ digital images under T-peeling

    NASA Astrophysics Data System (ADS)

    Nase, Michael; Rennert, Mirko; Naumenko, Konstantin; Eremeyev, Victor A.

    2016-06-01

    In this paper procedures are developed to identify traction-separation curves from digital images of the deformed flexible films during peeling. T-peel tests were performed for self-adhesive polymeric films. High quality photographs of the deformed shape within and outside the zone of adhesive interaction were made in situ by the digital light microscope. The deformed line is approximated by a power series with coefficients computed by minimizing a least squares functional. Two approaches to identify the traction-separation curve for the given deformation line are proposed. The first one is based on the energy integral of the non-linear theory of rods and allows the direct evaluation of the adhesion force potential. The second one utilizes the complementary energy type variational equation and the Ritz method to compute the adhesion force. The accuracy of both approaches is analyzed with respect to different approximations for the deformed line and the force of interaction. The obtained traction vs. axial coordinate and the traction-separation curves provide several properties of the adhesive system including the maximum adhesion force, the length of the adhesive zone and the equilibrium position, where the adhesive force is zero while the separation is positive.

  7. Model for adhesion clutch explains biphasic relationship between actin flow and traction at the cell leading edge

    PubMed Central

    Craig, Erin M.; Stricker, Jonathan; Gardel, Margaret L.; Mogilner, Alex

    2015-01-01

    Cell motility relies on the continuous reorganization of a dynamic actin-myosin-adhesion network at the leading edge of the cell, in order to generate protrusion at the leading edge and traction between the cell and its external environment. We analyze experimentally measured spatial distributions of actin flow, traction force, myosin density, and adhesion density in control and pharmacologically perturbed epithelial cells in order to develop a mechanical model of the actin-adhesion-myosin self-organization at the leading edge. A model in which the F-actin network is treated as a viscous gel, and adhesion clutch engagement is strengthened by myosin but weakened by actin flow, can explain the measured molecular distributions and correctly predict the spatial distributions of the actin flow and traction stress. We test the model by comparing its predictions with measurements of the actin flow and traction stress in cells with fast and slow actin polymerization rates. The model predicts how the location of the lamellipodium-lamellum boundary depends on the actin viscosity and adhesion strength. The model further predicts that the location of the lamellipodium-lamellum boundary is not very sensitive to the level of myosin contraction. PMID:25969948

  8. High-Force Versus Low-Force Lumbar Traction in Acute Lumbar Sciatica Due to Disc Herniation: A Preliminary Randomized Trial.

    PubMed

    Isner-Horobeti, Marie-Eve; Dufour, Stéphane Pascal; Schaeffer, Michael; Sauleau, Erik; Vautravers, Philippe; Lecocq, Jehan; Dupeyron, Arnaud

    This study compared the effects of high-force versus low-force lumbar traction in the treatment of acute lumbar sciatica secondary to disc herniation. A randomized double blind trial was performed, and 17 subjects with acute lumbar sciatica secondary to disc herniation were assigned to high-force traction at 50% body weight (BW; LT50, n = 8) or low force traction at 10% BW (LT10, n = 9) for 10 sessions in 2 weeks. Radicular pain (visual analogue scale [VAS]), lumbo-pelvic-hip complex motion (finger-to-toe test), lumbar-spine mobility (Schöber-Macrae test), nerve root compression (straight-leg-raising test), disability (EIFEL score), drug consumption, and overall evaluation of each patient were measured at days 0, 7, 1, 4, and 28. Significant (P < .05) improvements were observed in the LT50 and LT10 groups, respectively, between day 0 and day 14 (end of treatment) for VAS (-44% and -36%), EIFEL score (-43% and -28%) and overall patient evaluation (+3.1 and +2.0 points). At that time, LT50 specifically improved in the finger-to-toe test (-42%), the straight-leg-raising test (+58), and drug consumption (-50%). No significant interaction effect (group-by-time) was revealed, and the effect of traction treatment was independent of the level of medication. During the 2-week follow-up at day 28, only the LT10 group improved (P < .05) in VAS (-52%) and EIFEL scores (-46%). During this period, no interaction effect (group-by-time) was identified, and the observed responses were independent of the level of medication. For this preliminary study, patients with acute lumbar sciatica secondary to disc herniation who received 2 weeks of lumbar traction reported reduced radicular pain and functional impairment and improved well-being regardless of the traction force group to which they were assigned. The effects of the traction treatment were independent of the initial level of medication and appeared to be maintained at the 2-week follow-up. Copyright © 2016. Published by

  9. Vitrectomy outcomes in eyes with diabetic macular edema and vitreomacular traction.

    PubMed

    Haller, Julia A; Qin, Haijing; Apte, Rajendra S; Beck, Roy R; Bressler, Neil M; Browning, David J; Danis, Ronald P; Glassman, Adam R; Googe, Joseph M; Kollman, Craig; Lauer, Andreas K; Peters, Mark A; Stockman, Margaret E

    2010-06-01

    To evaluate vitrectomy for diabetic macular edema (DME) in eyes with at least moderate vision loss and vitreomacular traction. Prospective cohort study. The primary cohort included 87 eyes with DME and vitreomacular traction based on investigator's evaluation, visual acuity 20/63-20/400, optical coherence tomography (OCT) central subfield >300 microns and no concomitant cataract extraction at the time of vitrectomy. Surgery was performed according to the investigator's usual routine. Follow-up visits were performed after 3 months, 6 months (primary end point), and 1 year. Visual acuity, OCT retinal thickening, and operative complications. At baseline, median visual acuity in the 87 eyes was 20/100 and median OCT thickness was 491 microns. During vitrectomy, additional procedures included epiretinal membrane peeling in 61%, internal limiting membrane peeling in 54%, panretinal photocoagulation in 40%, and injection of corticosteroids at the close of the procedure in 64%. At 6 months, median OCT central subfield thickness decreased by 160 microns, with 43% having central subfield thickness <250 microns and 68% having at least a 50% reduction in thickening. Visual acuity improved by > or =10 letters in 38% (95% confidence interval, 28%-49%) and deteriorated by > or =10 letters in 22% (95% confidence interval, 13%-31%). Postoperative complications through 6 months included vitreous hemorrhage (5 eyes), elevated intraocular pressure requiring treatment (7 eyes), retinal detachment (3 eyes), and endophthalmitis (1 eye). Few changes in results were noted between 6 months and 1 year. After vitrectomy performed for DME and vitreomacular traction, retinal thickening was reduced in most eyes. Between 28% and 49% of eyes with characteristics similar to those included in this study are likely to have improvement of visual acuity, whereas between 13% and 31% are likely to have worsening. The operative complication rate is low and similar to what has been reported for this

  10. Effects of Different Angles of the Traction Table on Lumbar Spine Ligaments: A Finite Element Study.

    PubMed

    Farajpour, Hekmat; Jamshidi, Nima

    2017-12-01

    The traction bed is a noninvasive device for treating lower back pain caused by herniated intervertebral discs. In this study, we investigated the impact of the traction bed on the lower back as a means of increasing the disc height and creating a gap between facet joints. Computed tomography (CT) images were obtained from a female volunteer and a three-dimensional (3D) model was created using software package MIMICs 17.0. Afterwards, the 3D model was analyzed in an analytical software (Abaqus 6.14). The study was conducted under the following traction loads: 25%, 45%, 55%, and 85% of the whole body weight in different angles. Results indicated that the loading angle in the L3-4 area had 36.8%, 57.4%, 55.32%, 49.8%, and 52.15% effect on the anterior longitudinal ligament, posterior longitudinal ligament, intertransverse ligament, interspinous ligament, and supraspinous ligament, respectively. The respective values for the L4-5 area were 32.3%, 10.6%, 53.4%, 56.58%, and 57.35%. Also, the body weight had 63.2%, 42.6%, 44.68%, 50.2%, and 47.85% effect on the anterior longitudinal ligament, posterior longitudinal ligament, intertransverse ligament, interspinous ligament, and supraspinous ligament, respectively. The respective values for the L4-5 area were 67.7%, 89.4%, 46.6%, 43.42% and 42.65%. The authenticity of results was checked by comparing with the experimental data. The results show that traction beds are highly effective for disc movement and lower back pain relief. Also, an optimal angle for traction can be obtained in a 3D model analysis using CT or magnetic resonance imaging images. The optimal angle would be different for different patients and thus should be determined based on the decreased height of the intervertebral disc, weight and height of patients.

  11. Numerical modeling of the traction process in the treatment for Pierre-Robin Sequence.

    PubMed

    Słowiński, Jakub J; Czarnecka, Aleksandra

    2016-10-01

    The goal of this numerical study was to identify the results of modulated growth simulation of the mandibular bone during traction in Pierre-Robin Sequence (PRS) treatment. Numerical simulation was conducted in the Ansys 16.2 environment. Two FEM (finite elements method) models of a newborn's mandible (a spatial and a flat model) were developed. The procedure simulated a 20-week traction period. The adopted growth measure was mandibular length increase, defined as the distance between the Co-Pog anatomic points used in cephalometric analysis. The simulation calculations conducted on the developed models showed that modulation had a significant influence on the pace of bone growth. In each of the analyzed cases, growth modulation resulted in an increase in pace. The largest value of increase was 6.91 mm. The modulated growth with the most beneficial load variant increased the basic value of the growth by as much as 24.6%, and growth with the least beneficial variant increased by 7.4%. Traction is a simple, minimally invasive and inexpensive procedure. The proposed algorithm may enable the development of a helpful forecasting tool, which could be of real use to doctors working on Pierre-Robin Sequence and other mandibular deformations in children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Determinants of marginal traction alopecia in African girls and women.

    PubMed

    Khumalo, Nonhlanhla P; Jessop, Susan; Gumedze, Freedom; Ehrlich, Rodney

    2008-09-01

    Our recent population studies reported a prevalence of traction alopecia (TA) of 17.1% in African schoolgirls (6-21 years) and of 31.7% in women (18-86 years). More schoolgirls had chemically treated hair than women and disease presence was associated with hairstyles. The aim of this study was to investigate determinants of TA presence and severity in girls and women using data from both studies. Clinical assessment and a Marginal TA Severity score were used for diagnosis and disease severity, respectively. The data used included 574 schoolgirls and 604 women. The first analysis was multiple logistic regression for disease presence. Exploratory associations for disease severity were assessed using the Spearman rank correlation test. Adults were defined as age 18 years or older, irrespective of study. The odds ratio for TA was higher in adults than in children (<18 years) (1.87 [P < .001, 95% confidence interval 1.28-2.72]) and was higher with braiding-related than chemical-related symptoms. The highest risk of TA, compared with natural hair, occurred when traction was added to relaxed hair (odds ratio 3.47 [P < .001, 95% confidence interval 1.94-6.20]). Only 18.9% of patients with TA had never had symptoms related to hairdressing. TA severity was associated with age group, current hairstyle, and hairdressing symptoms. Participants with severe disease were too few to estimate determinants. There is a need for the validation of the Marginal TA Severity score with larger numbers and for future studies to include more participants with severe disease. Our findings suggest that avoiding both hairdressing symptoms and the addition of traction, especially to chemically processed hair, may reduce the risk of developing TA.

  13. Energy and wear optimisation of train longitudinal dynamics and of traction and braking systems

    NASA Astrophysics Data System (ADS)

    Conti, R.; Galardi, E.; Meli, E.; Nocciolini, D.; Pugi, L.; Rindi, A.

    2015-05-01

    Traction and braking systems deeply affect longitudinal train dynamics, especially when an extensive blending phase among different pneumatic, electric and magnetic devices is required. The energy and wear optimisation of longitudinal vehicle dynamics has a crucial economic impact and involves several engineering problems such as wear of braking friction components, energy efficiency, thermal load on components, level of safety under degraded or adhesion conditions (often constrained by the current regulation in force on signalling or other safety-related subsystem). In fact, the application of energy storage systems can lead to an efficiency improvement of at least 10% while, as regards the wear reduction, the improvement due to distributed traction systems and to optimised traction devices can be quantified in about 50%. In this work, an innovative integrated procedure is proposed by the authors to optimise longitudinal train dynamics and traction and braking manoeuvres in terms of both energy and wear. The new approach has been applied to existing test cases and validated with experimental data provided by Breda and, for some components and their homologation process, the results of experimental activities derive from cooperation performed with relevant industrial partners such as Trenitalia and Italcertifer. In particular, simulation results are referred to the simulation tests performed on a high-speed train (Ansaldo Breda Emu V250) and on a tram (Ansaldo Breda Sirio Tram). The proposed approach is based on a modular simulation platform in which the sub-models corresponding to different subsystems can be easily customised, depending on the considered application, on the availability of technical data and on the homologation process of different components.

  14. A novel anchorage technique for transnasal traction in rigid external maxillary distraction.

    PubMed

    Varol, A; Basa, S

    2013-12-01

    We describe an effective technique for anchorage of transnasal traction in the management of maxillary rotation during external distraction. Copyright © 2012 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. A Simple Force-Motion Relation for Migrating Cells Revealed by Multipole Analysis of Traction Stress

    PubMed Central

    Tanimoto, Hirokazu; Sano, Masaki

    2014-01-01

    For biophysical understanding of cell motility, the relationship between mechanical force and cell migration must be uncovered, but it remains elusive. Since cells migrate at small scale in dissipative circumstances, the inertia force is negligible and all forces should cancel out. This implies that one must quantify the spatial pattern of the force instead of just the summation to elucidate the force-motion relation. Here, we introduced multipole analysis to quantify the traction stress dynamics of migrating cells. We measured the traction stress of Dictyostelium discoideum cells and investigated the lowest two moments, the force dipole and quadrupole moments, which reflect rotational and front-rear asymmetries of the stress field. We derived a simple force-motion relation in which cells migrate along the force dipole axis with a direction determined by the force quadrupole. Furthermore, as a complementary approach, we also investigated fine structures in the stress field that show front-rear asymmetric kinetics consistent with the multipole analysis. The tight force-motion relation enables us to predict cell migration only from the traction stress patterns. PMID:24411233

  16. The application of a clinical prediction rule for patients with neck pain likely to benefit from cervical traction: A case report.

    PubMed

    Bernstetter, Andrew

    2016-10-01

    Cervical traction is a commonly utilized intervention in the treatment of patients with neck pain. In 2009, a clinical prediction rule (CPR) was developed as a way to assist clinicians in determining the patient population most likely to respond to cervical traction, though this CPR has yet to be validated. The purpose of this case report is to demonstrate the application of that CPR. The patient was a 46-year-old female with a four-week history of right-sided neck and shoulder pain, with numbness and tingling of her thumb and index finger. Treatment consisted of five sessions provided over 3 weeks. The plan of care included home mechanical cervical traction, exercise, and manual therapy. The patient achieved pain-free cervical range of motion. Neck disability index scores decreased from 28% to 6%, and the Patient-Specific Functional Scale average score improved from 5.5 to 10 out of 10. This case report demonstrates the application of a CPR to assist in deciding if cervical traction is an appropriate intervention. Further research is needed to validate the CPR and to establish the optimal mode of delivery for traction.

  17. Evaluation of an Empirical Traction Equation for Forestry Tires

    Treesearch

    C.R. Vechinski; C.E. Johnson; R.L. Raper

    1998-01-01

    Variable load test data were used to evaluate the applicability of an existing forestry tire traction model for a new forestry tire and a worn tire of the same size with and without tire chains in a range of soil conditions. `The clay and sandy soi!s ranged in moisture content from 17 to 28%. Soil bulk density varied between 1.1 and 1.4g cm-3...

  18. Strategies for Proximal Femoral Nailing of Unstable Intertrochanteric Fractures: Lateral Decubitus Position or Traction Table.

    PubMed

    Sonmez, Mesut Mehmet; Camur, Savas; Erturer, Erden; Ugurlar, Meric; Kara, Adnan; Ozturk, Irfan

    2017-03-01

    The aim of this prospective randomized study was to compare the traction table and lateral decubitus position techniques in the management of unstable intertrochanteric fractures. Eighty-two patients with unstable intertrochanteric fractures between 2011 and 2013 were included in this study. All patients were treated surgically with the Proximal Femoral Nail Antirotation implant (DePuy Synthes). Patients were randomized to undergo the procedure in the lateral decubitus position (42 patients) or with the use of a traction table (40 patients). Patients whose procedure was not performed entirely with a semi-invasive method or who required the use of additional fixation materials, such as cables, were excluded from the study. The groups were compared on the basis of the setup time, surgical time, fluoroscopic exposure time, tip-to-apex distance, collodiaphyseal angle, and modified Baumgaertner criteria for radiologic reduction. The setup time, surgical time, and fluoroscopic exposure time were lower and the differences were statistically significant in the lateral decubitus group compared with the traction table group. The collodiaphyseal angles were significantly different between the groups in favor of the lateral decubitus method. The tip-to-apex distance and the classification of reduction according to the modified Baumgaertner criteria did not demonstrate a statistically significant difference between the groups. The lateral decubitus position is used for most open procedures of the hip. We found that this position facilitates exposure for the surgical treatment of unstable intertrochanteric fractures and has advantages over the traction table in terms of set up time, surgical time and fluoroscopic exposure time.

  19. Comparison of Solid State Inverters for AC Induction Motor Traction Propulsion Systems

    DOT National Transportation Integrated Search

    1980-12-01

    This report is one of a series concerned with the application of ac machines as traction motors for railroad motive power. It presents results of a laboratory evaluation and computer analysis of different inverter systems. Three inverter systems, sin...

  20. E-Cadherin-Dependent Stimulation of Traction Force at Focal Adhesions via the Src and PI3K Signaling Pathways

    PubMed Central

    Jasaitis, Audrius; Estevez, Maruxa; Heysch, Julie; Ladoux, Benoit; Dufour, Sylvie

    2012-01-01

    The interplay between cadherin- and integrin-dependent signals controls cell behavior, but the precise mechanisms that regulate the strength of adhesion to the extracellular matrix remains poorly understood. We deposited cells expressing a defined repertoire of cadherins and integrins on fibronectin (FN)-coated polyacrylamide gels (FN-PAG) and on FN-coated pillars used as a micro-force sensor array (μFSA), and analyzed the functional relationship between these adhesion receptors to determine how it regulates cell traction force. We found that cadherin-mediated adhesion stimulated cell spreading on FN-PAG, and this was modulated by the substrate stiffness. We compared S180 cells with cells stably expressing different cadherins on μFSA and found that traction forces were stronger in cells expressing cadherins than in parental cells. E-cadherin-mediated contact and mechanical coupling between cells are required for this increase in cell-FN traction force, which was not observed in isolated cells, and required Src and PI3K activities. Traction forces were stronger in cells expressing type I cadherins than in cells expressing type II cadherins, which correlates with our previous observation of a higher intercellular adhesion strength developed by type I compared with type II cadherins. Our results reveal one of the mechanisms whereby molecular cross talk between cadherins and integrins upregulates traction forces at cell-FN adhesion sites, and thus provide additional insight into the molecular control of cell behavior. PMID:22853894

  1. Fatigue life analysis for traction drives with application to a toroidal type geometry

    NASA Technical Reports Server (NTRS)

    Coy, J. J.; Loewenthal, S. H.; Zaretsky, E. V.

    1976-01-01

    A contact fatigue life analysis for traction drives was developed which was based on a modified Lundberg-Palmgren theory. The analysis was used to predict life for a cone-roller toroidal traction drive. A 90-percent probability of survival was assumed for the calculated life. Parametric results were presented for life and Hertz contact stress as a function of load, drive ratio, and size. A design study was also performed. The results were compared to previously published work for the dual cavity toroidal drive as applied to a typical compact passenger vehicle drive train. For a representative duty cycle condition wherein the engine delivers 29 horsepower at 2000 rpm with the vehicle moving at 48.3 km/hr (30 mph) the drive life was calculated to be 19,200 km (11 900 miles).

  2. Tire-road friction estimation and traction control strategy for motorized electric vehicle.

    PubMed

    Jin, Li-Qiang; Ling, Mingze; Yue, Weiqiang

    2017-01-01

    In this paper, an optimal longitudinal slip ratio system for real-time identification of electric vehicle (EV) with motored wheels is proposed based on the adhesion between tire and road surface. First and foremost, the optimal longitudinal slip rate torque control can be identified in real time by calculating the derivative and slip rate of the adhesion coefficient. Secondly, the vehicle speed estimation method is also brought. Thirdly, an ideal vehicle simulation model is proposed to verify the algorithm with simulation, and we find that the slip ratio corresponds to the detection of the adhesion limit in real time. Finally, the proposed strategy is applied to traction control system (TCS). The results showed that the method can effectively identify the state of wheel and calculate the optimal slip ratio without wheel speed sensor; in the meantime, it can improve the accelerated stability of electric vehicle with traction control system (TCS).

  3. A simple force-motion relation for migrating cells revealed by multipole analysis of traction stress.

    PubMed

    Tanimoto, Hirokazu; Sano, Masaki

    2014-01-07

    For biophysical understanding of cell motility, the relationship between mechanical force and cell migration must be uncovered, but it remains elusive. Since cells migrate at small scale in dissipative circumstances, the inertia force is negligible and all forces should cancel out. This implies that one must quantify the spatial pattern of the force instead of just the summation to elucidate the force-motion relation. Here, we introduced multipole analysis to quantify the traction stress dynamics of migrating cells. We measured the traction stress of Dictyostelium discoideum cells and investigated the lowest two moments, the force dipole and quadrupole moments, which reflect rotational and front-rear asymmetries of the stress field. We derived a simple force-motion relation in which cells migrate along the force dipole axis with a direction determined by the force quadrupole. Furthermore, as a complementary approach, we also investigated fine structures in the stress field that show front-rear asymmetric kinetics consistent with the multipole analysis. The tight force-motion relation enables us to predict cell migration only from the traction stress patterns. Copyright © 2014 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  4. Height increase, neuromuscular function, and back pain during 6 degrees head-down tilt with traction

    NASA Technical Reports Server (NTRS)

    Styf, J. R.; Ballard, R. E.; Fechner, K.; Watenpaugh, D. E.; Kahan, N. J.; Hargens, A. R.

    1997-01-01

    BACKGROUND: Spinal lengthening and back pain are commonly experienced by astronauts exposed to microgravity. METHODS: To develop a ground-based simulation for spinal adaptation to microgravity, we investigated height increase, neuromuscular function and back pain in 6 subjects all of whom underwent two forms of bed rest for 3 d. One form consisted of 6 degrees of head-down tilt (HDT) with balanced traction, while the other was horizontal bed rest (HBR). Subjects had a 2-week recovery period in between the studies. RESULTS: Total body and spinal length increased significantly more and the subjects had significantly more back pain during HDT with balanced traction compared to HBR. The distance between the lower endplate of L4 and upper endplate of S1, as measured by ultrasonography, increased significantly in both treatments to the same degree. Intramuscular pressures in the erector spinae muscles and ankle torque measurements during plantarflexion and dorsiflexion did not change significantly during either treatment. CONCLUSION: Compared to HBR, HDT with balanced traction may be a better method to simulate changes of total body and spinal lengths, as well as back pain seen in microgravity.

  5. The wall traction induced by flowing red blood cells in model microvessels and its potential mechanotransduction

    NASA Astrophysics Data System (ADS)

    Freund, Jonathan; Vermot, Julien

    2013-11-01

    There is evidence in early embryonic development, even well before advective oxygen transport is important, that the presence of red bloods cells per se trigger essential steps of normal vascular development. For example, showed that sequestration of blood cells early in the development of a mouse, such that the hematocrit is reduced, suppresses normal vascular network development. Vascular development also provides a model for remodeling and angiogenesis. We consider the transient stresses associated with blood cells flowing in model microvessels of comparable diameter to those at early stages of development (6 μm to 12 μm). A detailed simulation tool is used to show that passing blood cells present a significant fluctuating traction signature on the vessel wall, well above the mean stresses. This is particularly pronounced for slow flows (<= 50 μm/s) or small diameters (<= 7 μm), for which root-mean-square wall traction fluctuations can exceed their mean. These events potentially present mechanotranduction triggers that direct development or remodeling. Attenuation of such fluctuating tractions by a viscoelastic endothelial glycocalyx layer is also considered. NSF supported.

  6. Cost effectiveness of using surgery versus skeletal traction in management of femoral shaft fractures at Thika level 5 hospital, Kenya.

    PubMed

    Opondo, Everisto; Wanzala, Peter; Makokha, Ansellimo

    2013-01-01

    A prospective quasi experimental study was undertaken at the Thika level 5 hospital. The study aimed to compare the costs of managing femoral shaft fracture by surgery as compared to skeletal traction. Sixty nine (46.6%) patients were enrolled in group A and managed surgically by intramedullary nailing while 79 (53.4%) patients were enrolled in group B and managed by skeletal traction. Exclusion criteria included patients with pathological fractures and previous femoral fractures. Data was collected by evaluation of patients in patient bills using a standardized questionnaire. The questionnaire included cost of haematological and radiological tests, bed fees, theatre fees and physiotherapy costs. The data was compiled and analyzed using SPSS version 16. Person's chi square and odds ratios were used to measure associations and risk analysis respectively. A higher proportion of patients (88.4%) in group A were hospitalized for less than one month compared to 20 patients (30.4%) in group B (p, 0.001).Total cost of treatment in group A was significantly lower than in group B. Nineteen (27.9%) patients who underwent surgery paid a total bill of Ksh 5000-7500 compared to 7(10.4%) who were treated by traction. The financial cost benefit of surgery was further complimented by better functional outcomes. The data indicates a cost advantage of managing femoral shaft fracture by surgery compared to traction. Furthermore the longer hospital stay in the traction group is associated with more malunion, limb deformity and shortening.

  7. Tire-road friction estimation and traction control strategy for motorized electric vehicle

    PubMed Central

    Jin, Li-Qiang; Yue, Weiqiang

    2017-01-01

    In this paper, an optimal longitudinal slip ratio system for real-time identification of electric vehicle (EV) with motored wheels is proposed based on the adhesion between tire and road surface. First and foremost, the optimal longitudinal slip rate torque control can be identified in real time by calculating the derivative and slip rate of the adhesion coefficient. Secondly, the vehicle speed estimation method is also brought. Thirdly, an ideal vehicle simulation model is proposed to verify the algorithm with simulation, and we find that the slip ratio corresponds to the detection of the adhesion limit in real time. Finally, the proposed strategy is applied to traction control system (TCS). The results showed that the method can effectively identify the state of wheel and calculate the optimal slip ratio without wheel speed sensor; in the meantime, it can improve the accelerated stability of electric vehicle with traction control system (TCS). PMID:28662053

  8. The value of radiographs obtained during forced traction under general anaesthesia in predicting flexibility in idiopathic scoliosis with Cobb angles exceeding 60 degree.

    PubMed

    Ibrahim, T; Gabbar, O A; El-Abed, K; Hutchinson, M J; Nelson, I W

    2008-11-01

    Our aim in this prospective radiological study was to determine whether the flexibility rate calculated from radiographs obtained during forced traction under general anaesthesia, was better than that of fulcrum-bending radiographs before corrective surgery in predicting the extent of the available correction in patients with idiopathic scoliosis. We evaluated 33 patients with a Cobb angle > 60 degrees on a standing posteroanterior radiograph, who had been treated by posterior correction. Pre-operative standing fulcrum-bending radiographs and those with forced-traction under general anaesthesia were obtained. Post-operative standing radiographs were taken after surgical correction. The mean forced-traction flexibility rate was 55% (SD 11.3) which was significantly higher than the mean fulcrum-bending flexibility rate of 32% (SD 16.1) (p < 0.001). We found no correlation between either the forced-traction or fulcrum-bending flexibility rates and the correction rate post-operatively (p = 0.24 and p = 0.44, respectively). Radiographs obtained during forced traction under general anaesthesia were better at predicting the flexibility of the curve than fulcrum-bending radiographs in curves with a Cobb angle > 60 degrees in the standing position and may identify those patients for whom supplementary anterior surgery can be avoided.

  9. [The use of Saunders lumbar traction in physiotherapy of patients with chronic lower back pain].

    PubMed

    Pingot, Julia; Pingot, Mariusz; Łabecka, Monika; Woldańska-Okońska, Marta

    2014-05-01

    Pain of the lower back is one of the most common ailments in modem society. Such frequent occurrence of back pain syndromes is a serious medical and social problem. Despite numerous attempts, there have not been comprehensive or decisive publications on the therapeutic standard for back pain syndromes that would cover all the aspects of the ailment. Partial report can change the attitude and shed new light on the treatment of these syndromes. The aim of this study was to evaluate the use of Saunders lumbar tractions in patients with chronic lower back pain in comparison with the group of patients undergoing pharmacological treatment. The study included 140 patients with chronic lower back pain who were divided into two groups. Each group consisted of 70 persons of mixed gender (the age mean value was 45). Group I were treated with the use of Saunders lumbar traction and Group II (control group) were treated pharmacologically. The following scales were used to assess pain and mobility of the lumbar part of the vertebral column (before treatment, in-treatment, right after treatment and 30 days after treatment): Laitinen, VAS, Rolland-Morris questionnaire and Schober functional test. The statistical analysis was performed with Greenhouse-Geisser test of within-subjects effects. In both the groups, a significant analgesic action and an improvement to spinal mobility were observed. Significantly better results were obtained in Group I where the patients had been treated with the use of Saunders lumbar traction. The pharmacological treatment applied in Group II showed an analgesic action and influenced positively the functional parameters of the patients. The effects, however, were much worse than in Group 1 where axial Saunders traction was applied to the lumbar part of the vertebral column.

  10. A scoping review of applications and outcomes of traction orthoses and constructs for the management of intra-articular fractures and fracture dislocations in the hand.

    PubMed

    Packham, Tara L; Ball, Pamela D; MacDermid, Joy C; Bain, James R; DalCin, Arianna

    2016-01-01

    Intra-articular hand fractures can have devastating consequences for movement and function. The unique nature of the injury and diverse management strategies are a challenge for conducting trials. To conduct a scoping review of traction constructs for the management of intra-articular hand fractures. We conducted a systematic search of the literature, extracting data on the scope and nature of the evidence for traction constructs. Our search yielded 87 articles addressing 3 traction constructs: (1) static traction (n = 17), (2) dynamic external fixation (n = 53), and (3) dynamic orthoses (n = 17). Active range of motion of the target joint was the most frequently reported outcome. Study designs included 36 cohorts, 21 case series, and 9 case studies: 24% contained only technical information. The current literature addressing traction constructs consists primarily of small and low-quality studies. Evidence synthesis could improve the estimation of range of motion outcomes but would not be able to identify the best treatment. Consensus on classification of fracture patterns, routine use of outcome measures, and randomized trials are needed to compare different traction constructs and inform evidence-based care. Scoping review. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  11. Investigation of brachial plexus traction lesions by peripheral and spinal somatosensory evoked potentials.

    PubMed Central

    Jones, S J

    1979-01-01

    Peripheral, spinal and cortical somatosensory evoked potentials were recorded in 26 patients with unilateral traction injuries of the brachial plexus ganglia. Of 10 cases explored surgically the recordings correctly anticipated the major site of the lesion in eight. PMID:422958

  12. Low-speed wind-tunnel investigation of a porous forebody and nose strakes for yaw control of a multirole fighter aircraft

    NASA Technical Reports Server (NTRS)

    Fears, Scott P.

    1995-01-01

    Low-speed wind-tunnel tests were conducted in the Langley 12-Foot Low-Speed Tunnel on a model of the Boeing Multirole Fighter (BMRF) aircraft. This single-seat, single-engine configuration was intended to be an F-16 replacement that would incorporate many of the design goals and advanced technologies of the F-22. Its mission requirements included supersonic cruise without afterburner, reduced observability, and the ability to attack both air-to-air and air-to-ground targets. So that it would be effective in all phases of air combat, the ability to maneuver at angles of attack up to and beyond maximum lift was also desired. Traditional aerodynamic yaw controls, such as rudders, are typically ineffective at these higher angles of attack because they are usually located in the wake from the wings and fuselage. For this reason, this study focused on investigating forebody-mounted controls that produces yawing moments by modifying the strong vortex flowfield being shed from the forebody at high angles of attack. Two forebody strakes were tested that varied in planform and chordwise location. Various patterns of porosity in the forebody skin were also tested that differed in their radial coverage and chordwise location. The tests were performed at a dynamic pressure of 4 lb/ft(exp 2) over an angle-of-attack range of -4 deg to 72 deg and a sideslip range of -10 deg to 10 deg. Static force data, static pressures on the surface of the forebody, and videotapes of flow-visualization using laser-illuminated smoke were obtained.

  13. Measurement of time-varying displacement fields in cell culture for traction force optical coherence microscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Mulligan, Jeffrey A.; Adie, Steven G.

    2017-02-01

    Mechanobiology is an emerging field which seeks to link mechanical forces and properties to the behaviors of cells and tissues in cancer, stem cell growth, and other processes. Traction force microscopy (TFM) is an imaging technique that enables the study of traction forces exerted by cells on their environment to migrate as well as sense and manipulate their surroundings. To date, TFM research has been performed using incoherent imaging modalities and, until recently, has been largely confined to the study of cell-induced tractions within two-dimensions using highly artificial and controlled environments. As the field of mechanobiology advances, and demand grows for research in physiologically relevant 3D culture and in vivo models, TFM will require imaging modalities that support such settings. Optical coherence microscopy (OCM) is an interferometric imaging modality which enables 3D cellular resolution imaging in highly scattering environments. Moreover, optical coherence elastography (OCE) enables the measurement of tissue mechanical properties. OCE relies on the principle of measuring material deformations in response to artificially applied stress. By extension, similar techniques can enable the measurement of cell-induced deformations, imaged with OCM. We propose traction force optical coherence microscopy (TF-OCM) as a natural extension and partner to existing OCM and OCE methods. We report the first use of OCM data and digital image correlation to track temporally varying displacement fields exhibited within a 3D culture setting. These results mark the first steps toward the realization of TF-OCM in 2D and 3D settings, bolstering OCM as a platform for advancing research in mechanobiology.

  14. Improved throughput traction microscopy reveals pivotal role for matrix stiffness in fibroblast contractility and TGF-β responsiveness

    PubMed Central

    Marinković, Aleksandar; Mih, Justin D.; Park, Jin-Ah; Liu, Fei

    2012-01-01

    Lung fibroblast functions such as matrix remodeling and activation of latent transforming growth factor-β1 (TGF-β1) are associated with expression of the myofibroblast phenotype and are directly linked to fibroblast capacity to generate force and deform the extracellular matrix. However, the study of fibroblast force-generating capacities through methods such as traction force microscopy is hindered by low throughput and time-consuming procedures. In this study, we improved at the detail level methods for higher-throughput traction measurements on polyacrylamide hydrogels using gel-surface-bound fluorescent beads to permit autofocusing and automated displacement mapping, and transduction of fibroblasts with a fluorescent label to streamline cell boundary identification. Together these advances substantially improve the throughput of traction microscopy and allow us to efficiently compute the forces exerted by lung fibroblasts on substrates spanning the stiffness range present in normal and fibrotic lung tissue. Our results reveal that lung fibroblasts dramatically alter the forces they transmit to the extracellular matrix as its stiffness changes, with very low forces generated on matrices as compliant as normal lung tissue. Moreover, exogenous TGF-β1 selectively accentuates tractions on stiff matrices, mimicking fibrotic lung, but not on physiological stiffness matrices, despite equivalent changes in Smad2/3 activation. Taken together, these results demonstrate a pivotal role for matrix mechanical properties in regulating baseline and TGF-β1-stimulated contraction of lung fibroblasts and suggest that stiff fibrotic lung tissue may promote myofibroblast activation through contractility-driven events, whereas normal lung tissue compliance may protect against such feedback amplification of fibroblast activation. PMID:22659883

  15. Combined preoperative traction with instrumented posterior occipitocervical fusion for severe ventral brainstem compression secondary to displaced os odontoideum: technical report of 2 cases.

    PubMed

    Abd-El-Barr, Muhammad M; Snyder, Brian D; Emans, John B; Proctor, Mark R; Hedequist, Daniel

    2016-12-01

    Severe os odontoideum causing ventral brainstem compression is a rare and difficult entity to treat. It is generally accepted that severe os odontoideum causing ventral brainstem compression and neurological deficits warrants surgical treatment. This often requires both anterior and posterior procedures. Anterior approaches to the craniocervical junction are fraught with complications, including infection and risk of injury to neurovascular structures. External traction systems traditionally require long-term bedrest. The authors report 2 cases of severe ventral brainstem compression secondary to displaced os odontoideum and describe their use of extended preoperative halo vest traction to reduce the severe kyphosis and improve neurological function, followed by posterior occipitocervical fusion. Postoperatively both patients showed remarkable improvements in their neurological function and kyphotic deformity. Preoperative halo vest traction combined with posterior occipitocervical fusion appears to be a safe and effective method to treat brainstem compression by severe os odontoideum. It allows for adequate decompression of ventral neural structures and improvement of neurological function, but it is not hindered by the risks of anterior surgical approaches and does not restrict patients to strict bedrest as traditional traction systems. This method of halo vest traction and posterior-only approaches may be transferable to other cervical instability issues with both anterior and posterior pathologies.

  16. Harmonic analysis of traction power supply system based on wavelet decomposition

    NASA Astrophysics Data System (ADS)

    Dun, Xiaohong

    2018-05-01

    With the rapid development of high-speed railway and heavy-haul transport, AC drive electric locomotive and EMU large-scale operation in the country on the ground, the electrified railway has become the main harmonic source of China's power grid. In response to this phenomenon, the need for timely monitoring of power quality problems of electrified railway, assessment and governance. Wavelet transform is developed on the basis of Fourier analysis, the basic idea comes from the harmonic analysis, with a rigorous theoretical model, which has inherited and developed the local thought of Garbor transformation, and has overcome the disadvantages such as window fixation and lack of discrete orthogonally, so as to become a more recently studied spectral analysis tool. The wavelet analysis takes the gradual and precise time domain step in the high frequency part so as to focus on any details of the signal being analyzed, thereby comprehensively analyzing the harmonics of the traction power supply system meanwhile use the pyramid algorithm to increase the speed of wavelet decomposition. The matlab simulation shows that the use of wavelet decomposition of the traction power supply system for harmonic spectrum analysis is effective.

  17. [Randomized controlled trials of needle knife therapy combined with rotation traction manipulation for the treatment of cervical spondylotic radiculopathy].

    PubMed

    Zhou, Zhong-Liang; Su, Guo-Hong; Zheng, Bao-Zhu; Zuo, Yu-Zhu; Wei, Fu-Liang

    2016-09-25

    To compare the therapeutic effects between needle knife therapy combined with rotation traction manipulation and rotation traction manipulation for the treatment of cervical spondylotic radiculopathy. From November 2013 to June 2015, 80 patients with cervical spondylotic radiculopathy meeting the inclusion criteria were divided into two groups randomly:the control group in which 39 patients were treated with rotation traction manipulation, and the treatment group in which 41 patients were treated with needle knife combined with rotation traction manipulation. The patients in the control group were treated once dayly for 2 weeks, which was 1 course. The patients in the treatment group were treated with needle knife firstly once a week for 2 weeks, which was 1 course;then were treated with the same methods as the patients in the control group. The symptoms, signs score and the therapeutic effects of the two groups before and after treatment were observed. After treatment, symptoms and signs scores declined in both groups( P <0.05). The results of the treatment group were better than effects in the control group( P <0.05). In the treatment group, 19 patients got an excellent result, 16 good, 5 fair and 1 bad;while in the control group, 10 patients got an excellent result, 10 good, 16 fair and 3 bad;the results of the treatment group were better than the results of the control group( P <0.01). Needle knife combined with rotation traction manipulation is an effective method for the treatment of cervical spondylotic radiculopathy, which is better than using manipulation method simply. Needle knife therapy has follow advantages:improving local blood circulation, reducing local content of pain substance, increasing production of substances resisting pain, opening channels and collaterals, and make body reaching new static and dynamic balance on the new foundation.

  18. Simultaneous Application of Fibrous Piezoresistive Sensors for Compression and Traction Detection in Glass Laminate Composites

    PubMed Central

    Nauman, Saad; Cristian, Irina; Koncar, Vladan

    2011-01-01

    This article describes further development of a novel Non Destructive Evaluation (NDE) approach described in one of our previous papers. Here these sensors have been used for the first time as a Piecewise Continuous System (PCS), which means that they are not only capable of following the deformation pattern but can also detect distinctive fracture events. In order to characterize the simultaneous compression and traction response of these sensors, multilayer glass laminate composite samples were prepared for 3-point bending tests. The laminate sample consisted of five layers of plain woven glass fabrics placed one over another. The sensors were placed at two strategic locations during the lay-up process so as to follow traction and compression separately. The reinforcements were then impregnated in epoxy resin and later subjected to 3-point bending tests. An appropriate data treatment and recording device has also been developed and used for simultaneous data acquisition from the two sensors. The results obtained, under standard testing conditions have shown that our textile fibrous sensors can not only be used for simultaneous detection of compression and traction in composite parts for on-line structural health monitoring but their sensitivity and carefully chosen location inside the composite ensures that each fracture event is indicated in real time by the output signal of the sensor. PMID:22163707

  19. Simultaneous application of fibrous piezoresistive sensors for compression and traction detection in glass laminate composites.

    PubMed

    Nauman, Saad; Cristian, Irina; Koncar, Vladan

    2011-01-01

    This article describes further development of a novel Non Destructive Evaluation (NDE) approach described in one of our previous papers. Here these sensors have been used for the first time as a Piecewise Continuous System (PCS), which means that they are not only capable of following the deformation pattern but can also detect distinctive fracture events. In order to characterize the simultaneous compression and traction response of these sensors, multilayer glass laminate composite samples were prepared for 3-point bending tests. The laminate sample consisted of five layers of plain woven glass fabrics placed one over another. The sensors were placed at two strategic locations during the lay-up process so as to follow traction and compression separately. The reinforcements were then impregnated in epoxy resin and later subjected to 3-point bending tests. An appropriate data treatment and recording device has also been developed and used for simultaneous data acquisition from the two sensors. The results obtained, under standard testing conditions have shown that our textile fibrous sensors can not only be used for simultaneous detection of compression and traction in composite parts for on-line structural health monitoring but their sensitivity and carefully chosen location inside the composite ensures that each fracture event is indicated in real time by the output signal of the sensor.

  20. Perfluorocarbon-perfused 23 gauge three-dimensional vitrectomy for complicated diabetic tractional retinal detachment

    PubMed Central

    Velez-Montoya, Raul; Guerrero-Naranjo, Jose Luis; Garcia-Aguirre, Gerardo; Morales-Cantón, Virgilio; Fromow-Guerra, Jans; Quiroz-Mercado, Hugo

    2011-01-01

    Background Perfluorocarbon liquid (PCL)-perfused vitrectomy has been shown in previous studies to be feasible, safe, and to have advantages in managing complicated cases of tractional retinal detachment. The present study had the objectives of describing the anatomical results and measuring surgical time and PCL consumption when combining PCL-perfused techniques with modern vitrectomy equipment. Methods A prospective, interventional consecutive case series was investigated. We enrolled patients with diabetic tractional retinal detachment, complicated by proliferative vitreoretinopathy and poor vision. A 23 gauge PCL-perfused vitrectomy was done with three-dimensional settings. During the procedure, we assessed the degree of surgical bleeding, visualization quality, and difficulty of membrane dissections. Visual acuity, intraocular pressure, and anatomical success were assessed at one and 3 months of follow-up. Results Twelve patients were enrolled in this study. There were no statistical significant changes in intraocular pressure and visual acuity throughout the follow-up period. Surgery was performed in a hemorrhage-free environment in almost all cases, with good visualization and low technical difficulty. The mean complete surgical time was 94.92 ± 25.03 minutes. The mean effective vitrectomy time was 22.50 ± 19.04 minutes and the mean PCL consumption was 25.08 ± 9.76 mL, with a speed of 1.11 mL/minute. Anatomical success was 67% at 3 months. Conclusion Although the technique proved to have some advantages in managing complicated cases of diabetic tractional retinal detachment, there was a high consumption of PCL. A redesign of the entire system is needed in order to decrease the amount of PCL needed for the technique. PMID:22267907

  1. 77 FR 4914 - Consumer Information Regulations; Fees for Use of Traction Skid Pads

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... found at 49 CFR 575.104. To aid consumers in making an informed choice in the purchase of passenger car..., App. B. Several commercial facilities also have traction skid pads. The current fees charged for use... these tires for purchase by manufacturers. Based on NHTSA's assessment using a ``market price'' analysis...

  2. The effect of cervical traction combined with neural mobilization on pain and disability in cervical radiculopathy. A case report.

    PubMed

    Savva, Christos; Giakas, Giannis

    2013-10-01

    Cervical radiculopathy is the result of cervical nerve root pathology that may lead to chronic pain and disability. Although manual therapy interventions including cervical traction and neural mobilization have been advocated to decrease pain and disability caused by cervical radiculopathy, their analgesic effect has been questioned due to the low quality of research evidence. The purpose of this paper is to present the effect of cervical traction combined with neural mobilization on pain and disability in a patient experiencing cervical radiculopathy. A 52-year-old woman presented with a 2 month history of neurological cervico-brachial pain and whose presentation was consistent with cervical radiculopathy. Cervical traction and a slider neural mobilization of the medial nerve were applied simultaneously to reduce the patient's pain and disability measured at baseline and at 2 and 4 weeks using the Numeric Pain Rating Scale, the Neck Disability Index and the Patient-Specific Functional Scale. Improvements in all outcome measures were noted over a period of four weeks. Scores in all outcome measures revealed that the patient's pain had almost disappeared and that she was able to perform her household chores and job tasks without difficulties and limitations. In conclusion, the findings of this study support that the application of cervical traction combined with neural mobilization can produce significant improvements in terms of pain and disability in cervical radiculopathy. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Dielectric elastomer actuator for the measurement of cell traction forces with sub-cellular resolution

    NASA Astrophysics Data System (ADS)

    Rosset, Samuel; Poulin, Alexandre; Zollinger, Alicia; Smith, Michael; Shea, Herbert

    2017-04-01

    We report on the use of dielectric elastomer actuators (DEAs) to measure the traction force field of cells with subcellular resolution. The study of cellular electrochemical and mechanical response to deformation is an important area of research, as mechanotransduction has been shown to be linked with fundamental cell functions, or the progression of diseases such as cancer or atherosclerosis. Experimental cell mechanics is based on two fundamental concepts: the ability to measure cell stiffness, and to apply controlled strains to small clusters of cells. However, there is a lack of tools capable of applying precise deformation to a small cell population while being compatible with an inverted microscope (stable focal plane, transparency, compactness, etc.). Here, we use an anisotropically prestretched silicone-based DEA to deform a soft (7.6kPa) polyacrylamide gel on which the cells are cultured. An array of micro-dots of fluorescent fibronectin is transferred on the gel by micro-contact printing and serves as attachment points for the cells. In addition, the fluorescent dots (which have a diameter of 2 μm with a spacing of 6 μm) are used during the experiment to monitor the traction forces of a single cell (or small cluster of cells). The cell locally exerts traction on the gel, thus deforming the matrix of dots. The position of dots versus time is monitored live when the cells are submitted to a uniaxial strain step. Our deformable bioreactor enables the measurement of the local stiffness of cells submitted to mechanical strain, and is fully compatible with an inverted microscope set-up.

  4. Pelvic packing with vaginal traction for the management of intractable hemorrhage.

    PubMed

    Naranjo-Gutiérrez, Leonardo A; Oliva-Cristerna, Joaquín; Ramírez-Montiel, Martha L; Ortiz, Mario I

    2014-10-01

    To present clinical cases examining the effectiveness and safety of pelvic packing with vaginal traction for inhibiting obstetric hemorrhage among women receiving treatment at a public obstetrics and gynecology tertiary care hospital in Mexico. In a retrospective observational descriptive study, eight cases of obstetric hemorrhage treated by pelvic packing with vaginal traction between January 2012 and December 2013 at Hospital de la Mujer, Mexico City, Mexico, were reviewed. The mean patient age was 28.8±6.8 years. The average blood loss was 4535±897 mL. Uterine atony was the cause of bleeding among six patients: histopathologic examination revealed two cases of placenta accreta, one case of placenta percreta, two cases of uteroplacental apoplexy, and one case of myomatosis. For two patients, placental separation was difficult and required surgical management. The packing technique was effective for all patients. No patients presented with infection or required re-operation for bleeding management. No deaths occurred. For management of bleeding among patients with underlying coagulation disorders, pelvic packing can be useful when standard techniques such as hysterectomy, tubal hypogastric ligation, and/or pharmacologic therapy are unsuccessful. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Safety and efficacy of endoscopic submucosal dissection using IT knife nano with clip traction method for early esophageal squamous cell carcinoma.

    PubMed

    Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo

    2018-01-01

    Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.

  6. Acute quadriplegia following closed traction reduction of a cervical facet dislocation in the setting of ossification of the posterior longitudinal ligament: case report.

    PubMed

    Wimberley, David W; Vaccaro, Alexander R; Goyal, Nitin; Harrop, James S; Anderson, D Greg; Albert, Todd J; Hilibrand, Alan S

    2005-08-01

    A case report of acute quadriplegia resulting from closed traction reduction of traumatic bilateral cervical facet dislocation in a 54-year-old male with concomitant ossification of the posterior longitudinal ligament (OPLL). To report an unusual presentation of a spinal cord injury, examine the approach to reversal of the injury, and review the treatment and management controversies of acute cervical facet dislocations in specific patient subgroups. The treatment of acute cervical facet dislocations is an area of ongoing controversy, especially regarding the question of the necessity of advanced imaging studies before closed traction reduction of the dislocated cervical spine. The safety of an immediate closed, traction reduction of the cervical spine in awake, alert, cooperative, and appropriately select patients has been reported in several studies. To date, there have been no permanent neurologic deficits resulting from awake, closed reduction reported in the literature. A case of temporary, acute quadriplegia with complete neurologic recovery following successful closed traction reduction of a bilateral cervical facet dislocation in the setting of OPLL is presented. The clinical neurologic examination, radiographic, and advanced imaging studies before and after closed, traction reduction of a cervical facet dislocation are evaluated and discussed. A review of the literature regarding the treatment of acute cervical facet dislocations is presented. Radiographs showed approximately 50% subluxation of the fifth on the sixth cervical vertebrae, along with computerized tomography revealing extensive discontinuous OPLL. The cervical facet dislocation was successfully reduced with an awake, closed traction reduction, before magnetic resonance imaging (MRI) evaluation. The patient subsequently had acute quadriplegia develop, with the ensuing MRI study illustrating severe spinal stenosis at the C5, C6 level as a result of OPLL or a large extruded disc herniation

  7. Traction studies of northeast corridor rail passenger service: Executive summary

    NASA Technical Reports Server (NTRS)

    Macie, T. W.; Stallkamp, J. A.

    1980-01-01

    The enabling legislation of 1976 for improvement of service in the Northeast corridor (NEC) requires a schedule of 2 h 40 min between Washington and New York City by 1981 and 3 h 40 min between NYC and Boston, when the electrification is completed. Various options of the NEC operation that may satisfy the legislation were investigated, particularly in terms of travel time and energy consumption. NEC operations were compared with overseas systems and practices. The emerging new technology of AC traction was also evaluated.

  8. Design study of a continuously variable roller cone traction CVT for electric vehicles

    NASA Technical Reports Server (NTRS)

    Mccoin, D. K.; Walker, R. D.

    1980-01-01

    Continuously variable ratio transmissions (CVT) featuring cone and roller traction elements and computerized controls are studied. The CVT meets or exceeds all requirements set forth in the design criteria. Further, a scalability analysis indicates the basic concept is applicable to lower and higher power units, with upward scaling for increased power being more readily accomplished.

  9. A dynamic traction splint for the management of extrinsic tendon tightness.

    PubMed

    Dovelle, S; Heeter, P K; Phillips, P D

    1987-02-01

    The dynamic traction splint designed by therapists at Walter Reed Army Medical Center is used for the management of extrinsic extensor tendon tightness commonly seen in brachial plexus injuries and traumatic soft tissue injuries of the upper extremity. The two components of the splint allow for simultaneous maximum flexion of the MCP and IP joints. This simple and economical splint provides an additional modality to any occupational therapy service involved in the management of upper extremity disorders.

  10. Effect of positive pulse charge waveforms on the energy efficiency of lead-acid traction cells

    NASA Technical Reports Server (NTRS)

    Smithrick, J. J.

    1981-01-01

    The effects of four different charge methods on the energy conversion efficiency of 300 ampere hour lead acid traction cells were investigated. Three of the methods were positive pulse charge waveforms; the fourth, a constant current method, was used as a baseline of comparison. The positive pulse charge waveforms were: 120 Hz full wave rectified sinusoidal; 120 Hz silicon controlled rectified; and 1 kHz square wave. The constant current charger was set at the time average pulse current of each pulse waveform, which was 150 amps. The energy efficiency does not include charger losses. The lead acid traction cells were charged to 70 percent of rated ampere hour capacity in each case. The results of charging the cells using the three different pulse charge waveforms indicate there was no significant difference in energy conversion efficiency when compared to constant current charging at the time average pulse current value.

  11. A tissue adaptation model based on strain-dependent collagen degradation and contact-guided cell traction.

    PubMed

    Heck, T A M; Wilson, W; Foolen, J; Cilingir, A C; Ito, K; van Donkelaar, C C

    2015-03-18

    Soft biological tissues adapt their collagen network to the mechanical environment. Collagen remodeling and cell traction are both involved in this process. The present study presents a collagen adaptation model which includes strain-dependent collagen degradation and contact-guided cell traction. Cell traction is determined by the prevailing collagen structure and is assumed to strive for tensional homeostasis. In addition, collagen is assumed to mechanically fail if it is over-strained. Care is taken to use principally measurable and physiologically meaningful relationships. This model is implemented in a fibril-reinforced biphasic finite element model for soft hydrated tissues. The versatility and limitations of the model are demonstrated by corroborating the predicted transient and equilibrium collagen adaptation under distinct mechanical constraints against experimental observations from the literature. These experiments include overloading of pericardium explants until failure, static uniaxial and biaxial loading of cell-seeded gels in vitro and shortening of periosteum explants. In addition, remodeling under hypothetical conditions is explored to demonstrate how collagen might adapt to small differences in constraints. Typical aspects of all essentially different experimental conditions are captured quantitatively or qualitatively. Differences between predictions and experiments as well as new insights that emerge from the present simulations are discussed. This model is anticipated to evolve into a mechanistic description of collagen adaptation, which may assist in developing load-regimes for functional tissue engineered constructs, or may be employed to improve our understanding of the mechanisms behind physiological and pathological collagen remodeling. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. VITRECTOMY FOR INTERMEDIATE AGE-RELATED MACULAR DEGENERATION ASSOCIATED WITH TANGENTIAL VITREOMACULAR TRACTION: A CLINICOPATHOLOGIC CORRELATION.

    PubMed

    Ziada, Jean; Hagenau, Felix; Compera, Denise; Wolf, Armin; Scheler, Renate; Schaumberger, Markus M; Priglinger, Siegfried G; Schumann, Ricarda G

    2018-03-01

    To describe the morphologic characteristics of the vitreomacular interface in intermediate age-related macular degeneration associated with tangential traction due to premacular membrane formation and to correlate with optical coherence tomography (OCT) findings and clinical data. Premacular membrane specimens were removed sequentially with the internal limiting membrane from 27 eyes of 26 patients with intermediate age-related macular degeneration during standard vitrectomy. Specimens were processed for immunocytochemical staining of epiretinal cells and extracellular matrix components. Ultrastructural analysis was performed using transmission electron microscopy. Spectral domain optical coherence tomography images and patient charts were evaluated in retrospect. Immunocytochemistry revealed hyalocytes and myofibroblasts as predominant cell types. Ultrastructural analysis demonstrated evidence of vitreoschisis in all eyes. Myofibroblasts with contractile properties were observed to span between folds of the internal limiting membrane and vitreous cortex collagen. Retinal pigment epithelial cells or inflammatory cells were not detected. Mean visual acuity (Snellen) showed significant improvement from 20/72 ± 20/36 to 20/41 ± 20/32 (P < 0.001) after a mean follow-up period of 19 months (median, 17 months). During this period, none of the eyes required anti-vascular endothelial growth factor therapy. Fibrocellular premacular proliferation in intermediate age-related macular degeneration predominantly consists of vitreous collagen, hyalocytes, and myofibroblasts with contractile properties. Vitreoschisis and vitreous-derived cells appear to play an important role in traction formation of this subgroup of eyes. In patients with intermediate age-related macular degeneration and contractile premacular membrane, release of traction by vitrectomy with internal limiting membrane peeling results in significantly functional and anatomical improvement.

  13. Microscale evidence of liquefaction and its potential triggers during soft-bed deformation within subglacial traction tills

    NASA Astrophysics Data System (ADS)

    Phillips, Emrys R.; Evans, David J. A.; van der Meer, Jaap J. M.; Lee, Jonathan R.

    2018-02-01

    Published conceptual models argue that much of the forward motion of modern and ancient glaciers is accommodated by deformation of soft-sediments within the underlying bed. At a microscale this deformation results in the development of a range of ductile and brittle structures in water-saturated sediments as they accommodate the stresses being applied by the overriding glacier. Detailed micromorphological studies of subglacial traction tills reveal that these polydeformed sediments may also contain evidence of having undergone repeated phases of liquefaction followed by solid-state shear deformation. This spatially and temporally restricted liquefaction of subglacial traction tills lowers the shear strength of the sediment and promotes the formation of "transient mobile zones" within the bed, which accommodate the shear imposed by the overriding ice. This process of soft-bed sliding, alternating with bed deformation, facilitates glacier movement by way of 'stick-slip' events. The various controls on the slip events have previously been identified as: (i) the introduction of pressurised meltwater into the bed, a process limited by the porosity and permeability of the till; and (ii) pressurisation of porewater as a result of subglacial deformation; to which we include (iii) episodic liquefaction of water-saturated subglacial traction tills in response to glacier seismic activity (icequakes), which are increasingly being recognized as significant processes in modern glaciers and ice sheets. As liquefaction operates only in materials already at very low values of effective stress, its process-form signatures are likely indicative of glacier sub-marginal tills.

  14. Progressive halo-vest traction preceding posterior occipitocervical instrumented fusion for irreducible atlantoaxial dislocation and basilar invagination.

    PubMed

    Li, Peng; Bao, Deming; Cheng, Huijuan; Meng, Fanshuai; Li, Junwei

    2017-11-01

    Surgical treatment of irreducible atlantoaxial dislocation (IAAD) with basilar invagination (BI) is associated with high rates of severe complications, including mortality. This retrospective study investigated the safety and efficacy of progressive halo-vest traction for IAAD with BI prior to posterior occipitocervical instrumented fusion. Between 2009 and 2013, 39 patients with IAAD with BI underwent preoperative reduction by progressive halo-vest traction for 20.82±4.21days. Instrumented fusion was then performed through a posterior approach. Clinical outcomes were based on pain scale and Japanese Orthopedic Association (JOA) scores. Radiographic analysis evaluated changes in atlantodental distance, McGregor's line violation, spinal canal width at the craniocervical junction, cervicomedullary angle, C2-C7 lordosis angle, and the occiput-C2 angle. Follow-ups ranged from 48 to 96 months. Both atlantodental distance and BI significantly improved in all patients. The rates of complete anatomical reduction were 85% for IAAD, and 95% for BI. Most of the patients reported satisfactory pain relief and improvement in daily activity; the mean JOA scores at baseline and last follow-up were 9.10 and 15.92, respectively. Although complications occurred in 10 patients (25.64%), all of which healed uneventfully. The bony fusion rate was 100%. Progressive halo-vest traction before surgery is safe and effective for reduction of IAAD with BI. The technique we describe is a promising method for treatment of complex craniocervical junction deformity. Copyright © 2017. Published by Elsevier B.V.

  15. Cervical Radiculopathy: Effectiveness of Adding Traction to Physical Therapy-A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Romeo, Antonio; Vanti, Carla; Boldrini, Valerio; Ruggeri, Martina; Guccione, Andrew A; Pillastrini, Paolo; Bertozzii, Lucia

    2018-04-01

    Cervical radiculopathy (CR) is a common cervical spine disorder. Cervical traction (CT) is a frequently recommended treatment for patients with CR. The purpose of this study was to conduct a review and meta-analysis of randomized controlled trials (RCTs) on the effect of CT combined with other physical therapy procedures versus physical therapy procedures alone on pain and disability. Data were obtained from COCHRANE Controlled Trials Register, PubMed, CINAHL, Scopus, ISI Web of Science, and PEDro, from their inception to July 2016. All RCTs on symptomatic adults with CR, without any restriction regarding publication time or language, were considered. Two reviewers selected the studies, conducted the quality assessment, and extracted the results. Meta-analysis employed a random-effects model. The evidence was assessed using GRADE criteria. Five studies met the inclusion criteria. Mechanical traction had a significant effect on pain at short- and intermediate-terms (g = -0.85 [95% CI = -1.63 to -0.06] and g = -1.17 [95% CI = -2.25 to -0.10], respectively) and significant effects on disability at intermediate term (g = -1.05; 95% CI = -1.81 to -0.28). Manual traction had significant effects on pain at short- term (g = -0.85; 95% CI = -1.39 to -0.30). The most important limitation of the present work is the lack of homogeneity in CR diagnostic criteria among the included studies. In light of these results, the current literature lends some support to the use of the mechanical and manual traction for CR in addition to other physical therapy procedures for pain reduction, but yielding lesser effects on function/disability.

  16. EFFECTS OF A MODIFIED VITRECTOMY PROBE IN SMALL-GAUGE VITRECTOMY: An Experimental Study on the Flow and on the Traction Exerted on the Retina.

    PubMed

    Rizzo, Stanislao; Fantoni, Gualtiero; de Santis, Giovanni; Lue, Jaw-Chyng Lormen; Ciampi, Jonathan; Palla, Michele; Genovesi Ebert, Federica; Savastano, Alfonso; De Maria, Carmelo; Vozzi, Giovanni; Brant Fernandes, Rodrigo A; Faraldi, Francesco; Criscenti, Giuseppe

    2017-09-01

    Thorough this experimental study, the physic features of a modified 23-gauge vitrectomy probe were evaluated in vitro. A modified vitrectomy probe to increase vitreous outflow rate with a small-diameter probe, that also minimized tractional forces on the retina, was created and tested. The "new" probe was created by drilling an opening into the inner duct of a traditional 23-gauge probe with electrochemical or electrodischarge micromachining. Both vitreous outflow and tractional forces on the retina were examined using experimental models of vitreous surgery. The additional opening allowed the modified probe to have a cutting rate of 5,000 cuts per minute, while sustaining an outflow approximately 45% higher than in conventional 23-gauge probes. The modified probe performed two cutting actions per cycle, not one, as in standard probes. Because tractional force is influenced by cutting rate, retinal forces were 2.2 times lower than those observed with traditional cutters. The modified probe could be useful in vitreoretinal surgery. It allows for faster vitreous removal while minimizing tractional forces on the retina. Moreover, any available probe can be modified by creating a hole in the inner duct.

  17. Multiphoton photochemical crosslinking-based fabrication of protein micropatterns with controllable mechanical properties for single cell traction force measurements

    NASA Astrophysics Data System (ADS)

    Tong, Ming Hui; Huang, Nan; Zhang, Wei; Zhou, Zhuo Long; Ngan, Alfonso Hing Wan; Du, Yanan; Chan, Barbara Pui

    2016-01-01

    Engineering 3D microstructures with predetermined properties is critical for stem cell niche studies. We have developed a multiphoton femtosecond laser-based 3D printing platform, which generates complex protein microstructures in minutes. Here, we used the platform to test a series of fabrication and reagent parameters in precisely controlling the mechanical properties of protein micropillars. Atomic force microscopy was utilized to measure the reduced elastic modulus of the micropillars, and transmission electron microscopy was used to visualize the porosity of the structures. The reduced elastic modulus of the micropillars associated positively and linearly with the scanning power. On the other hand, the porosity and pore size of the micropillars associated inversely and linearly with the scanning power and reagent concentrations. While keeping the elastic modulus constant, the stiffness of the micropillars was controlled by varying their height. Subsequently, the single cell traction forces of rabbit chondrocytes, human dermal fibroblasts, human mesenchymal stem cells, and bovine nucleus pulposus cells (bNPCs) were successfully measured by culturing the cells on micropillar arrays of different stiffness. Our results showed that the traction forces of all groups showed positive relationship with stiffness, and that the chondrocytes and bNPCs generated the highest and lowest traction forces, respectively.

  18. Methods of the aerodynamical experiments with simulation of massflow-traction ratio of the power unit

    NASA Astrophysics Data System (ADS)

    Lokotko, A. V.

    2016-10-01

    Modeling massflow-traction characteristics of the power unit (PU) may be of interest in the study of aerodynamic characteristics (ADC) aircraft models with full dynamic likeness, and in the study of the effect of interference PU. These studies require the use of a number of processing methods. These include: 1) The method of delivery of the high-pressure body of jets model engines on the sensitive part of the aerodynamic balance. 2) The method of estimate accuracy and reliability of measurement thrust generated by the jet device. 3) The method of implementation of the simulator SU in modeling the external contours of the nacelle, and the conditions at the inlet and outlet. 4) The method of determining the traction simulator PU. 5) The method of determining the interference effect from the work of power unit on the ADC of model. 6) The method of producing hot jets of jet engines. The paper examines implemented in ITAM methodology applied to testing in a supersonic wind tunnel T-313.

  19. Modeling of traction-coupling properties of wheel propulsor

    NASA Astrophysics Data System (ADS)

    Sakhapov, R. L.; Nikolaeva, R. V.; Gatiyatullin, M. H.; Makhmutov, M. M.

    2017-12-01

    In conditions of operation of aggregates on soils with low bearing capacity, the main performance indicators of their operation are determined by the properties of retaining the functional qualities of the propulsor. Therefore, the parameters of the anti-skid device can not be calculated by only one criterion. The equipment of propellers with anti-skid devices, which allow to reduce the compaction effect of the propulsion device on the soil, seems to be a rational solution to the problem of increasing traction and coupling properties of the driving wheels. The mathematical model is based on the study of the interaction of the driving wheel with anti-skid devices and a deformable bearing surface, which takes into account the wheel diameter, skid coefficient, the parameters of the anti-skid device, the physical and mechanical properties of the soil. As a basic mathematical model that determines the dependence of the coupling properties on the wheel parameters, the model obtained as a result of integration and reflecting the process of soil deformation from the shear stress is adopted. The total value of the resistance forces will determine the force of the hitch pressure on the horizontal soil layers, and the value of its deformation is the degree of wheel slippage. When the anti-skid devices interact with the soil, the traction capacity of the wheel is composed of shear forces, soil shear and soil deformation forces with detachable hooks. As a result of the interaction of the hook with the soil, the latter presses against the walls of the hook with the force equal to the sum of the hook load and the resistance to movement. During operation, the linear dimensions of the hook will decrease, which is not taken into account by the safety factor. Abrasive wear of the thickness of the hook is approximately proportional to the work of friction caused by the movement of the hook when inserted into the soil and slipping the wheel.

  20. On the equivalence between traction- and stress-based approaches for the modeling of localized failure in solids

    NASA Astrophysics Data System (ADS)

    Wu, Jian-Ying; Cervera, Miguel

    2015-09-01

    This work investigates systematically traction- and stress-based approaches for the modeling of strong and regularized discontinuities induced by localized failure in solids. Two complementary methodologies, i.e., discontinuities localized in an elastic solid and strain localization of an inelastic softening solid, are addressed. In the former it is assumed a priori that the discontinuity forms with a continuous stress field and along the known orientation. A traction-based failure criterion is introduced to characterize the discontinuity and the orientation is determined from Mohr's maximization postulate. If the displacement jumps are retained as independent variables, the strong/regularized discontinuity approaches follow, requiring constitutive models for both the bulk and discontinuity. Elimination of the displacement jumps at the material point level results in the embedded/smeared discontinuity approaches in which an overall inelastic constitutive model fulfilling the static constraint suffices. The second methodology is then adopted to check whether the assumed strain localization can occur and identify its consequences on the resulting approaches. The kinematic constraint guaranteeing stress boundedness and continuity upon strain localization is established for general inelastic softening solids. Application to a unified stress-based elastoplastic damage model naturally yields all the ingredients of a localized model for the discontinuity (band), justifying the first methodology. Two dual but not necessarily equivalent approaches, i.e., the traction-based elastoplastic damage model and the stress-based projected discontinuity model, are identified. The former is equivalent to the embedded and smeared discontinuity approaches, whereas in the later the discontinuity orientation and associated failure criterion are determined consistently from the kinematic constraint rather than given a priori. The bi-directional connections and equivalence conditions

  1. 3.0T MR imaging of the ankle: Axial traction for morphological cartilage evaluation, quantitative T2 mapping and cartilage diffusion imaging-A preliminary study.

    PubMed

    Jungmann, Pia M; Baum, Thomas; Schaeffeler, Christoph; Sauerschnig, Martin; Brucker, Peter U; Mann, Alexander; Ganter, Carl; Bieri, Oliver; Rummeny, Ernst J; Woertler, Klaus; Bauer, Jan S

    2015-08-01

    To determine the impact of axial traction during high resolution 3.0T MR imaging of the ankle on morphological assessment of articular cartilage and quantitative cartilage imaging parameters. MR images of n=25 asymptomatic ankles were acquired with and without axial traction (6kg). Coronal and sagittal T1-weighted (w) turbo spin echo (TSE) sequences with a driven equilibrium pulse and sagittal fat-saturated intermediate-w (IMfs) TSE sequences were acquired for morphological evaluation on a four-point scale (1=best, 4=worst). For quantitative assessment of cartilage degradation segmentation was performed on 2D multislice-multiecho (MSME) SE T2, steady-state free-precession (SSFP; n=8) T2 and SSFP diffusion-weighted imaging (DWI; n=8) images. Wilcoxon-tests and paired t-tests were used for statistical analysis. With axial traction, joint space width increased significantly and delineation of cartilage surfaces was rated superior (P<0.05). Cartilage surfaces were best visualized on coronal T1-w images (P<0.05). Differences for cartilage matrix evaluation were smaller. Subchondral bone evaluation, motion artifacts and image quality were not significantly different between the acquisition methods (P>0.05). T2 values were lower at the tibia than at the talus (P<0.001). Reproducibility was better for images with axial traction. Axial traction increased the joint space width, allowed for better visualization of cartilage surfaces and improved compartment discrimination and reproducibility of quantitative cartilage parameters. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Electric vehicle traction motors - The development of an advanced motor concept

    NASA Technical Reports Server (NTRS)

    Campbell, P.

    1980-01-01

    An axial-field permanent magnet traction motor is described, similar to several advanced motors that are being developed in the United States. This type of machine has several advantages over conventional dc motors, particularly in the electric vehicle application. The rapidly changing cost of magnetic materials, particularly cobalt, makes it important to study the utilization of permanent magnet materials in such machines. The impact of different magnets on machine design is evaluated, and the advantages of using iron powder composites in the armature are assessed.

  3. On the Formulation of Weakly Singular Displacement/Traction Integral Equations; and Their Solution by the MLPG Method

    NASA Technical Reports Server (NTRS)

    Atluri, Satya N.; Shen, Shengping

    2002-01-01

    In this paper, a very simple method is used to derive the weakly singular traction boundary integral equation based on the integral relationships for displacement gradients. The concept of the MLPG method is employed to solve the integral equations, especially those arising in solid mechanics. A moving Least Squares (MLS) interpolation is selected to approximate the trial functions in this paper. Five boundary integral Solution methods are introduced: direct solution method; displacement boundary-value problem; traction boundary-value problem; mixed boundary-value problem; and boundary variational principle. Based on the local weak form of the BIE, four different nodal-based local test functions are selected, leading to four different MLPG methods for each BIE solution method. These methods combine the advantages of the MLPG method and the boundary element method.

  4. Defining Strong State Accountability Systems: How Can Better Standards Gain Greater Traction? A First Look

    ERIC Educational Resources Information Center

    Reed, Eileen; Scull, Janie; Slicker, Gerilyn; Winkler, Amber M.

    2012-01-01

    Rigorous standards and aligned assessments are vital tools for boosting education outcomes but they have little traction without strong accountability systems that attach consequences to performance. In this pilot study, Eileen Reed, Janie Scull, Gerilyn Slicker, and Amber Winkler lay out the essential features of such accountability systems,…

  5. Probing for Exoplanets Hiding in Dusty Debris Disks: Disk Imaging, Characterization, and Exploration with HST-STIS Multi-roll Coronagraphy

    NASA Technical Reports Server (NTRS)

    Schneider, Glenn; Grady, Carol A.; Hines, Dean C.; Stark, Christopher C.; Debes, John; Carson, Joe; Kuchner, Marc J.; Perrin, Marshall; Weinberger, Alycia; Wisniewski, John P.; hide

    2014-01-01

    Spatially resolved scattered-light images of circumstellar debris in exoplanetary systems constrain the physical properties and orbits of the dust particles in these systems. They also inform on co-orbiting (but unseen) planets, the systemic architectures, and forces perturbing the starlight-scattering circumstellar material. Using HST/STIS broadband optical coronagraphy, we have completed the observational phase of a program to study the spatial distribution of dust in a sample of ten circumstellar debris systems, and one "mature" protoplanetrary disk all with HST pedigree, using PSF-subtracted multi-roll coronagraphy. These observations probe stellocentric distances greater than or equal to 5 AU for the nearest systems, and simultaneously resolve disk substructures well beyond corresponding to the giant planet and Kuiper belt regions within our own Solar System. They also disclose diffuse very low-surface brightness dust at larger stellocentric distances. Herein we present new results inclusive of fainter disks such as HD92945 (F (sub disk) /F (sub star) = 5x10 (sup -5) confirming, and better revealing, the existence of a narrow inner debris ring within a larger diffuse dust disk. Other disks with ring-like sub-structures and significant asymmetries and complex morphologies include: HD181327 for which we posit a spray of ejecta from a recent massive collision in an exo-Kuiper belt; HD61005 suggested to be interacting with the local ISM; HD15115 and HD32297, discussed also in the context of putative environmental interactions. These disks, and HD15745, suggest that debris system evolution cannot be treated in isolation. For AU Mic's edge-on disk we find out-of-plane surface brightness asymmetries at greater than or equal to 5 AU that may implicate the existence of one or more planetary perturbers. Time resolved images of the MP Mus proto-planetary disk provide spatially resolved temporal variability in the disk illumination. These and other new images from our HST

  6. The Technical Problems of Anti-theft Diagnostics in a Traction Network

    NASA Astrophysics Data System (ADS)

    Mikulski, Jerzy; Młynczak, Jakub

    2012-02-01

    The paper presents an analysis of traction lines theft in the Katowice division of the Railroad Development Company (Zakład Linii Kolejowych - ZLK) as well as the principles for the anti-theft protection system, currently in development. The problem of theft is a very important issue concerning the safety of rail transportation. It is also a significant economic problem, as the cost of recreating a stolen network is very high. Moreover, the Administrator of the infrastructure bears the cost of compensation for any delays in train schedules.

  7. Maintenance of working capacity of movement mechanism of load trolley with linear traction electric drive of bridge type crane.

    NASA Astrophysics Data System (ADS)

    Goncharov, K. A.; Denisov, I. A.

    2017-10-01

    The article considers the influence of the air gap size between the linear motor elements on the stability of the traction drive of the movement mechanism of the trolley of the bridge type crane. The main factors affecting the air gap size and the causes of their occurrence are described. The technique of calculating the magnitude of air gap variation is described in relation to the general deformation of the crane metal structure. Recommendations on the need for installation of additional equipment for load trolleys of various designs are given. The optimal values of the length of the trolley base are proposed. Observance of these values ensures normal operation of the traction drive.

  8. Active management of the third stage of labor with and without controlled cord traction: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Du, Yongming; Ye, Man; Zheng, Feiyun

    2014-07-01

    To determine the specific effect of controlled cord traction in the third stage of labor in the prevention of postpartum hemorrhage. We searched PubMed, Scopus and Web of Science (inception to 30 October 2013). Randomized controlled trials comparing controlled cord traction with hands-off management in the third stage of labor were included. Five randomized controlled trials involving a total of 30 532 participants were eligible. No significant difference was found between controlled cord traction and hands-off management groups with respect to the incidence of severe postpartum hemorrhage (relative risk 0.91, 95% confidence interval 0.77-1.08), need for blood transfusion (relative risk 0.96, 95% confidence interval 0.69-1.33) or therapeutic uterotonics (relative risk 0.94, 95% confidence interval 0.88-1.01). However, controlled cord traction reduced the incidence of postpartum hemorrhage in general (relative risk 0.93, 95% confidence interval 0.87-0.99; number-needed-to-treat 111, 95% confidence interval 61-666), as well manual removal of the placenta (relative risk 0.70, 95% confidence interval 0.58-0.84) and duration of the third stage of labor (mean difference -3.20, 95% confidence interval -3.21 to -3.19). Controlled cord traction appears to reduce the risk of any postpartum hemorrhage in a general sense, as well as manual removal of the placenta and the duration of the third stage of labor. However, the reduction in the occurrence of severe postpartum hemorrhage, need for additional uterotonics and blood transfusion is not statistically significant. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.

  9. The outcomes of pars plana vitrectomy without endotamponade for tractional retinal detachment secondary to proliferative diabetic retinopathy

    PubMed Central

    Qamar, Rao Muhammad Rashad; Saleem, Muhammad Imran; Saleem, Muhammad Farhan

    2013-01-01

    AIM To evaluate the outcomes of pars plana vitrectomy (PPV) without the use of an ocular tamponade in patients having tractional retinal detachment (TRD) secondary to proliferative diabetic retinopathy (PDR). METHODS It was an interventional study conducted at the Department of Ophthalmology, B.V. Hospital, Bahawalpur, Pakistan, from July 2011 to July 2012. A total of 75 patients (84 eyes) having TRD secondary to PDR were treated by PPV without using an ocular tamponade. All patients included in the study had a tractional retinal detachment secondary to proliferative diabetic retinopathy but didn't have or develop retinal breaks before or during the study period. The surgical procedure included a PPV combined with the removal of the tractional retinal membranes and the application of endolaser photocoagulation to the retina. The mean follow-up period was 12 months. RESULTS Successful retinal reattachement was observed in 78 of the operated eyes (92.8%). In these patients, the retina remained attached till the end of the one year follow-up period. Improvement in best corrected visual acuity (BCVA) was seen in 63 eyes (75%). The visual acuity remained unchanged in 9 eyes (10.7%). Mean improvement in BCVA was 2.00+1.24 at baseline to 1.24+1.22 (P<0.05) at the end of the follow-up period. CONCLUSION In the absence of the retinal breaks, a TRD secondary to PDR can be successfully treated by pars plana vitrectomy without the use of an ocular tamponade. PMID:24195047

  10. Traction esophageal diverticulum: a rare cause of gastro-intestinal bleeding.

    PubMed

    Ballehaninna, Umashankar K; Shaw, Jason P; Brichkov, Igor

    2012-12-01

    Esophageal diverticula are uncommon lesions that are usually classified according to their location (cervical, thoracic, or epiphrenic), or underlying pathogenesis (pulsion or traction), and their morphology (true or false).The majority of esophageal diverticula are acquired lesions that occur predominantly in elderly adults. Pulsion, or false, diverticula are the most commonly encountered type of esophageal diverticula noticed at the level of cricopharyngeus muscle, occur as a localized outpouchings that lacks a muscular coat, and as such their wall is formed entirely by mucosa and submucosa. True, or traction, esophageal diverticulum (TED) is seen in the middle one third of the thoracic esophagus in a peribronchial location, occurs secondary to mediastinal inflammatory lesions such as tuberculosis or histoplasmosis. The resultant desmoplastic reaction in the paraesophageal tissue causes full thickness pinching on the esophageal wall, producing a conical, broad-mouthed true diverticulum. They often project to the right side because subcarinal lymph nodes in this area are closely associated with the right anterior wall of the esophagus. TED usually presents with symptoms such as dysphagia, postural regurgitation, belching, retrosternal pain, heartburn, and epigastric pain. As in patients with pharyngoesophageal (Zenker's) diverticula, pulmonary symptoms are often present but underestimated in TED patients. These symptoms range from mild nocturnal cough to life-threatening massive aspiration. In this particular report we describe a rare case of TED presenting as a symptomatic upper gastrointestinal bleeding. Diagnostic evaluation of TED includes chest X-ray, barium esophagogram and manometry. A significant proportion of lower esophageal diverticula are associated with motility disorders. Management of TED include treating the underlying cause sometimes a surgical resection of diverticulum along with esophageal myotomy is necessitated in symptomatic patients.

  11. Investigation of control system of traction electric drive with feedbacks on load

    NASA Astrophysics Data System (ADS)

    Kuznetsov, N. K.; Iov, I. A.; Iov, A. A.

    2018-03-01

    In the article, by the example of a walking excavator, the results of a study of a control system of traction electric drive with a rigid and flexible feedback on the load are mentioned. Based on the analysis of known works, the calculation scheme has been chosen; the equations of motion of the electromechanical system have been obtained, taking into account the elasticity of the rope and feedbacks on the load in the elastic element. A simulation model of this system has been developed and mathematical modeling of the transient processes to evaluate the influence of feedback on the dynamic characteristics of the mechanism and its efficiency of work was carried out. It is shown that the use of rigid and flexible feedbacks makes it possible to reduce dynamic loads in the traction mechanism and to limit the elastic oscillation of the executive mechanism in transient operating modes in comparison with the standard control system; however, there is some decrease in productivity. It has been also established that the sign-variable of the loading of the electric drive, connected with the opening of the backlashes in the gearbox due to the action of feedbacks on the load in the elastic element, under certain conditions, can lead to undesirable phenomena in the operation of the drive and a decrease in the reliability of its operation.

  12. Therapeutic effects of flurbiprofen axetil on mesenteric traction syndrome: randomized clinical trial.

    PubMed

    Takahashi, Hidemasa; Shida, Dai; Tagawa, Kyoko; Iwamoto, Ryo; Arita, Makoto; Arai, Hiroyuki; Suzuki, Takeo

    2017-08-11

    This study aimed to reveal the appropriate timing for the intravenous administration of flurbiprofen axetil for preventing mesenteric traction syndrome (MTS), caused by prostacyclin release. In this prospective, randomized, clinical study, forty-five patients who were undergoing elective surgery for colorectal cancer via laparotomy were enrolled. Patients were randomly divided into 3 groups: a preoperative group (n = 16) receiving flurbiprofen axetil directly before surgery; a post-MTS group (n = 14) receiving following MTS onset; and a control group (n = 15) who were not administered flurbiprofen axetil. 6-keto-PGF1α, a stable metabolite of prostacyclin, levels were measured and mean blood pressures were recorded. In the preoperative group, 6-keto-PGF1α levels did not increase, blood pressure levels did not decrease, and no facial flushing was observed. In both the post-MTS and control groups, 6-keto-PGF1α levels increased markedly after mesenteric traction and blood pressure decreased significantly. The post-MTS group exhibited a faster decreasing trend in 6-keto-PGF1α levels and quick restore of the mean blood pressure, and the use of vasopressors and phenylephrine were lower than that in the control group. Even therapeutic administration of flurbiprofen axetil after the onset of MTS has also effects on MTS by suppressing prostacyclin production. Clinical trial number: UMIN000009111 . (Registered 14 October 2012).

  13. Finger-Shaped GelForce: Sensor for Measuring Surface Traction Fields for Robotic Hand.

    PubMed

    Sato, K; Kamiyama, K; Kawakami, N; Tachi, S

    2010-01-01

    It is believed that the use of haptic sensors to measure the magnitude, direction, and distribution of a force will enable a robotic hand to perform dexterous operations. Therefore, we develop a new type of finger-shaped haptic sensor using GelForce technology. GelForce is a vision-based sensor that can be used to measure the distribution of force vectors, or surface traction fields. The simple structure of the GelForce enables us to develop a compact finger-shaped GelForce for the robotic hand. GelForce that is developed on the basis of an elastic theory can be used to calculate surface traction fields using a conversion equation. However, this conversion equation cannot be analytically solved when the elastic body of the sensor has a complicated shape such as the shape of a finger. Therefore, we propose an observational method and construct a prototype of the finger-shaped GelForce. By using this prototype, we evaluate the basic performance of the finger-shaped GelForce. Then, we conduct a field test by performing grasping operations using a robotic hand. The results of this test show that using the observational method, the finger-shaped GelForce can be successfully used in a robotic hand.

  14. Modeling the mechanics of cells in the cell-spreading process driven by traction forces

    NASA Astrophysics Data System (ADS)

    Fang, Yuqiang; Lai, King W. C.

    2016-04-01

    Mechanical properties of cells and their mechanical interaction with the extracellular environments are main factors influencing cellular function, thus indicating the progression of cells in different disease states. By considering the mechanical interactions between cell adhesion molecules and the extracellular environment, we developed a cell mechanical model that can characterize the mechanical changes in cells during cell spreading. A cell model was established that consisted of various main subcellular components, including cortical cytoskeleton, nuclear envelope, actin filaments, intermediate filaments, and microtubules. We demonstrated the structural changes in subcellular components and the changes in spreading areas during cell spreading driven by traction forces. The simulation of nanoindentation tests was conducted by integrating the indenting force to the cell model. The force-indentation curve of the cells at different spreading states was simulated, and the results showed that cell stiffness increased with increasing traction forces, which were consistent with the experimental results. The proposed cell mechanical model provides a strategy to investigate the mechanical interactions of cells with the extracellular environments through the adhesion molecules and to reveal the cell mechanical properties at the subcellular level as cells shift from the suspended state to the adherent state.

  15. Modeling the mechanics of cells in the cell-spreading process driven by traction forces.

    PubMed

    Fang, Yuqiang; Lai, King W C

    2016-04-01

    Mechanical properties of cells and their mechanical interaction with the extracellular environments are main factors influencing cellular function, thus indicating the progression of cells in different disease states. By considering the mechanical interactions between cell adhesion molecules and the extracellular environment, we developed a cell mechanical model that can characterize the mechanical changes in cells during cell spreading. A cell model was established that consisted of various main subcellular components, including cortical cytoskeleton, nuclear envelope, actin filaments, intermediate filaments, and microtubules. We demonstrated the structural changes in subcellular components and the changes in spreading areas during cell spreading driven by traction forces. The simulation of nanoindentation tests was conducted by integrating the indenting force to the cell model. The force-indentation curve of the cells at different spreading states was simulated, and the results showed that cell stiffness increased with increasing traction forces, which were consistent with the experimental results. The proposed cell mechanical model provides a strategy to investigate the mechanical interactions of cells with the extracellular environments through the adhesion molecules and to reveal the cell mechanical properties at the subcellular level as cells shift from the suspended state to the adherent state.

  16. Manual unloading of the lumbar spine: can it identify immediate responders to mechanical traction in a low back pain population? A study of reliability and criterion referenced predictive validity

    PubMed Central

    Swanson, Brian T.; Riley, Sean P.; Cote, Mark P.; Leger, Robin R.; Moss, Isaac L.; Carlos,, John

    2016-01-01

    Background To date, no research has examined the reliability or predictive validity of manual unloading tests of the lumbar spine to identify potential responders to lumbar mechanical traction. Purpose To determine: (1) the intra and inter-rater reliability of a manual unloading test of the lumbar spine and (2) the criterion referenced predictive validity for the manual unloading test. Methods Ten volunteers with low back pain (LBP) underwent a manual unloading test to establish reliability. In a separate procedure, 30 consecutive patients with LBP (age 50·86±11·51) were assessed for pain in their most provocative standing position (visual analog scale (VAS) 49·53±25·52 mm). Patients were assessed with a manual unloading test in their most provocative position followed by a single application of intermittent mechanical traction. Post traction, pain in the provocative position was reassessed and utilized as the outcome criterion. Results The test of unloading demonstrated substantial intra and inter-rater reliability K = 1·00, P = 0·002, K = 0·737, P = 0·001, respectively. There were statistically significant within group differences for pain response following traction for patients with a positive manual unloading test (P<0·001), while patients with a negative manual unloading test did not demonstrate a statistically significant change (P>0·05). There were significant between group differences for proportion of responders to traction based on manual unloading response (P = 0·031), and manual unloading response demonstrated a moderate to strong relationship with traction response Phi = 0·443, P = 0·015. Discussion and conclusion The manual unloading test appears to be a reliable test and has a moderate to strong correlation with pain relief that exceeds minimal clinically important difference (MCID) following traction supporting the validity of this test. PMID:27559274

  17. A Conforming Multigrid Method for the Pure Traction Problem of Linear Elasticity: Mixed Formulation

    NASA Technical Reports Server (NTRS)

    Lee, Chang-Ock

    1996-01-01

    A multigrid method using conforming P-1 finite element is developed for the two-dimensional pure traction boundary value problem of linear elasticity. The convergence is uniform even as the material becomes nearly incompressible. A heuristic argument for acceleration of the multigrid method is discussed as well. Numerical results with and without this acceleration as well as performance estimates on a parallel computer are included.

  18. Surgical management of C-type subaxial cervical fractures using cervical traction followed by anterior cervical discectomy and fusion within 12 h after the trauma.

    PubMed

    Donnarumma, Pasquale; Bozzini, Vincenzo; Rizzi, Gaetano; Berardi, Arturo; Merlicco, Gaetano

    2017-01-01

    This was a retrospective cohort study. To report our 10-year experience of closed reduction using Crutchfield traction followed by anterior cervical discectomy and fusion within 12 h from injury for C-type subaxial cervical fractures (according to the AOSpine classification system). Clinical records and neuroimaging were retrospectively reviewed. Surgical details were provided. A total of 22 patients were included in the study. The cervical fracture was diagnosed after whole-body computed tomography scan on admission in all cases. Crutchfield traction was applied within 1-5 h from the diagnosis. Surgery consisting of anterior microdiscectomy and fusion with interbody cage and plating was performed 6-12 h after traction positioning. Most patients (19, 86%) had spinal cord injury: 7 were Frankel A (31%), 3 Frankel B (14%), 6 Frankel C (27%), 3 Frankel D (14%), and 3 Frankel E (14%). No neurologic deterioration was observed after the treatment. In 10 cases (45%), neurological symptoms improved 1 year after the trauma. Two patients (10%) died for complication related to spinal cord transition or other organ damage. Early reduction gives the best chance of recovery for patients affected by C-type subaxial cervical fracture. Rapid traction is more often successful and safer than manipulation under anesthesia. After close reduction achieving, anterior microdiscectomy, cage, and plating implant seem to be safe and effective with a low rate of complications.

  19. Inverted Nipple Correction with Selective Dissection of Lactiferous Ducts Using an Operative Microscope and a Traction Technique.

    PubMed

    Sowa, Yoshihiro; Itsukage, Sizu; Morita, Daiki; Numajiri, Toshiaki

    2017-10-01

    An inverted nipple is a common congenital condition in young women that may cause breastfeeding difficulty, psychological distress, repeated inflammation, and loss of sensation. Various surgical techniques have been reported for correction of inverted nipples, and all have advantages and disadvantages. Here, we report a new technique for correction of an inverted nipple using an operative microscope and traction that results in low recurrence and preserves lactation function and sensation. Between January 2010 and January 2013, we treated eight inverted nipples in seven patients with selective lactiferous duct dissection using an operative microscope. An opposite Z-plasty was added at the junction of the nipple and areola. Postoperatively, traction was applied through an apparatus made from a rubber gasket attached to a sterile syringe. Patients were followed up for 15-48 months. Adequate projection was achieved in all patients, and there was no wound dehiscence or complications such as infection. Three patients had successful pregnancies and subsequent breastfeeding that was not adversely affected by the treatment. There was no loss of sensation in any patient during the postoperative period. Our technique for treating an inverted nipple is effective and preserves lactation function and nipple sensation. The method maintains traction for a longer period, which we believe increases the success rate of the surgery for correction of severely inverted nipples. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. A study of various synthetic routes to produce a halogen-labeled traction fluid

    NASA Technical Reports Server (NTRS)

    Jones, W. R., Jr.; Zimmer, H.

    1978-01-01

    Several synthetic routes were studied for the synthesis of the compound 1, 1, 3-trimethyl-1, 3-dicyclohexyl-2 chloropropane. This halogen-labeled fluid would be of use in the study of high traction lubricants under elastohydrodynamic lubrication conditions using infrared emission spectroscopy. The synthetic routes included: dimerization of alpha-methylstyrene, methanol addition to alpha-methylstyrene, a Wittig reaction, and an organometallic approach. Because of steric hindrance and competing reactions, none of these routes were successful.

  1. Novel Transverse Flux Machine for Vehicle Traction Applications: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wan, Z.; Ahmed, A.; Husain, I.

    2015-04-02

    A novel transverse flux machine topology for electric vehicle traction applications using ferrite magnets is presented in this paper. The proposed transverse flux topology utilizes novel magnet arrangements in the rotor that are similar to the Halbach array to boost flux linkage; on the stator side, cores are alternately arranged around a pair of ring windings in each phase to make use of the entire rotor flux that eliminates end windings. Analytical design considerations and finite-element methods are used for an optimized design of a scooter in-wheel motor. Simulation results from finite element analysis (FEA) show that the motor achievedmore » comparable torque density to conventional rare-earth permanent magnet (PM) machines. This machine is a viable candidate for direct-drive applications with low cost and high torque density.« less

  2. A Novel Transverse Flux Machine for Vehicle Traction Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wan, Zhao; Ahmed, Adeeb; Husain, Iqbal

    2015-10-05

    A novel transverse flux machine topology for electric vehicle traction application using ferrite magnets is presented in this paper. The proposed transverse flux topology utilizes novel magnet arrangements in the rotor that are similar to Halbach-array to boost flux linkage; on the stator side, cores are alternately arranged around a pair of ring windings in each phase to make use of the entire rotor flux that eliminates end windings. Analytical design considerations and finite element methods are used for an optimized design of a scooter in-wheel motor. Simulation results from Finite Element Analysis (FEA) show the motor achieved comparable torquemore » density to conventional rare-earth permanent magnet machines. This machine is a viable candidate for direct drive applications with low cost and high torque density.« less

  3. Etude de l'influence de la temperature et de l'humidite sur les proprietes mecaniques en traction des fibres de chanvre et de coco

    NASA Astrophysics Data System (ADS)

    Ho Thi, Thu Nga

    L'objectif de cette etude fut d'etablir l'effet de l'humidite et de la temperature sur la resistance en traction et le module elastique des fibres de chanvre et de coco. Deux etudes ont ete realisees afin d'atteindre cet objectif. La premiere vise l'absorption de l'humidite dans ces fibres en exposition dans l'air (de 0%RH a 80%RH) ainsi que l'absorption de l'eau dans ces fibres immergees dans l'eau aux differentes temperatures. La deuxieme consiste a mesurer la resistance en traction et le module elastique de ces fibres sous differentes conditions d'humidite et de temperature. En basant sur les resultats experimentaux obtenus, les methodes semi empiriques et de reseaux de neurones ont ete utilisees pour but de predire les proprietes en traction (resistance et module d'elasticite) des fibres de chanvre et de coco sous l'influence de l'humidite et de la temperature.

  4. The Effect of 2 Forms of Talocrural Joint Traction on Dorsiflexion Range of Motion and Postural Control in Those With Chronic Ankle Instability.

    PubMed

    Powden, Cameron J; Hogan, Kathleen K; Wikstrom, Erik A; Hoch, Matthew C

    2017-05-01

    Talocrural joint mobilizations are commonly used to address deficits associated with chronic ankle instability (CAI). Examine the immediate effects of talocrural joint traction in those with CAI. Blinded, crossover. Laboratory. Twenty adults (14 females; age = 23.80 ± 4.02 y; height = 169.55 ± 12.38 cm; weight = 78.34 ± 16.32 kg) with self-reported CAI participated. Inclusion criteria consisted of a history of ≥1 ankle sprain, ≥2 episodes of giving way in the previous 3 mo, answering "yes" to ≥4 questions on the Ankle Instability Instrument, and ≤24 on the Cumberland Ankle Instability Tool. Subjects participated in 3 sessions in which they received a single treatment session of sustained traction (ST), oscillatory traction (OT), or a sham condition in a randomized order. Interventions consisted of four 30-s sets of traction with 1 min of rest between sets. During ST and OT, the talus was distracted distally from the ankle mortise to the end-range of accessory motion. ST consisted of continuous distraction and OT involved 1-s oscillations between the mid and end-range of accessory motion. The sham condition consisted of physical contact without force application. Preintervention and postintervention measurements of weight-bearing dorsiflexion, dynamic balance, and static single-limb balance were collected. The independent variable was treatment (ST, OT, sham). The dependent variables included pre-to-posttreatment change scores for the WBLT (cm), normalized SEBTAR (%), and time-to-boundary (TTB) variables(s). Separate 1-way ANOVAs examined differences between treatments for each dependent variable. Alpha was set a priori at P < .05. No significant treatment effects were identified for any variables. A single intervention of ST or OT did not produce significant changes in weight-bearing dorsiflexion range of motion or postural control in individuals with CAI. Future research should investigate the effects of repeated talocrural traction treatments and the

  5. FRET measurements of cell-traction forces and nano-scale clustering of adhesion ligands varied by substrate stiffness.

    PubMed

    Kong, Hyun Joon; Polte, Thomas R; Alsberg, Eben; Mooney, David J

    2005-03-22

    The mechanical properties of cell adhesion substrates regulate cell phenotype, but the mechanism of this relation is currently unclear. It may involve the magnitude of traction force applied by the cell, and/or the ability of the cells to rearrange the cell adhesion molecules presented from the material. In this study, we describe a FRET technique that can be used to evaluate the mechanics of cell-material interactions at the molecular level and simultaneously quantify the cell-based nanoscale rearrangement of the material itself. We found that these events depended on the mechanical rigidity of the adhesion substrate. Furthermore, both the proliferation and differentiation of preosteoblasts (MC3T3-E1) correlated to the magnitude of force that cells generate to cluster the cell adhesion ligands, but not the extent of ligand clustering. Together, these data demonstrate the utility of FRET in analyzing cell-material interactions, and suggest that regulation of phenotype with substrate stiffness is related to alterations in cellular traction forces.

  6. Data-based fault-tolerant control of high-speed trains with traction/braking notch nonlinearities and actuator failures.

    PubMed

    Song, Qi; Song, Yong-Duan

    2011-12-01

    This paper investigates the position and velocity tracking control problem of high-speed trains with multiple vehicles connected through couplers. A dynamic model reflecting nonlinear and elastic impacts between adjacent vehicles as well as traction/braking nonlinearities and actuation faults is derived. Neuroadaptive fault-tolerant control algorithms are developed to account for various factors such as input nonlinearities, actuator failures, and uncertain impacts of in-train forces in the system simultaneously. The resultant control scheme is essentially independent of system model and is primarily data-driven because with the appropriate input-output data, the proposed control algorithms are capable of automatically generating the intermediate control parameters, neuro-weights, and the compensation signals, literally producing the traction/braking force based upon input and response data only--the whole process does not require precise information on system model or system parameter, nor human intervention. The effectiveness of the proposed approach is also confirmed through numerical simulations.

  7. Vacuum-assisted wound closure and mesh-mediated fascial traction for open abdomen therapy - a systematic review.

    PubMed

    Acosta, Stefan; Björck, Martin; Petersson, Ulf

    2017-01-01

    The aim of this paper was to review the literature on vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) in open abdomen therapy. It was designed as systematic review of observational studies. A Pub Med, EMBASE and Cochrane search from 2007/01-2016/07 was performed combining the Medical Subject Headings "vacuum", "mesh-mediated fascial traction", "temporary abdominal closure", "delayed abdominal closure", "open abdomen", "abdominal compartment syndrome", "negative pressure wound therapy" or "vacuum assisted wound closure". Eleven original studies were found including patients numbering from 7 to 111. Six studies were prospective and five were retrospective. Nine studies were on mixed surgical (n = 9), vascular (n = 6) and trauma (n = 6) patients, while two were exclusively on vascular patients. The primary fascial closure rate per protocol varied from 80-100%. The time to closure of the open abdomen varied between 9-32 days. The entero-atmospheric fistula rate varied from 0-10.0%. The in-hospital survival rate varied from 57-100%. In the largest prospective study, the incisional hernia rate among survivors at 63 months of median follow-up was 54% (27/50), and 16 (33%) repairs out of 48 incisional hernias were performed throughout the study period. The study patients reported lower short form health survey (SF-36) scores than the mean reference population, mainly dependent on the prevalence of major co-morbidities. There was no difference in SF-36 scores or a modified ventral hernia pain questionnaire (VHPQ) at 5 years of follow up between those with versus those without incisional hernias. A high primary fascial closure rate can be achieved with the vacuum-assisted wound closure and meshmediated fascial traction technique in elderly, mainly non-trauma patients, in need of prolonged open abdomen therapy.

  8. Harmonic analysis of electric locomotive and traction power system based on wavelet singular entropy

    NASA Astrophysics Data System (ADS)

    Dun, Xiaohong

    2018-05-01

    With the rapid development of high-speed railway and heavy-haul transport, the locomotive and traction power system has become the main harmonic source of China's power grid. In response to this phenomenon, the system's power quality issues need timely monitoring, assessment and governance. Wavelet singular entropy is an organic combination of wavelet transform, singular value decomposition and information entropy theory, which combines the unique advantages of the three in signal processing: the time-frequency local characteristics of wavelet transform, singular value decomposition explores the basic modal characteristics of data, and information entropy quantifies the feature data. Based on the theory of singular value decomposition, the wavelet coefficient matrix after wavelet transform is decomposed into a series of singular values that can reflect the basic characteristics of the original coefficient matrix. Then the statistical properties of information entropy are used to analyze the uncertainty of the singular value set, so as to give a definite measurement of the complexity of the original signal. It can be said that wavelet entropy has a good application prospect in fault detection, classification and protection. The mat lab simulation shows that the use of wavelet singular entropy on the locomotive and traction power system harmonic analysis is effective.

  9. Interactions between the L1 cell adhesion molecule and ezrin support traction-force generation and can be regulated by tyrosine phosphorylation.

    PubMed

    Sakurai, Takeshi; Gil, Orlando D; Whittard, John D; Gazdoiu, Mihaela; Joseph, Todd; Wu, James; Waksman, Adam; Benson, Deanna L; Salton, Stephen R; Felsenfeld, Dan P

    2008-09-01

    An Ig superfamily cell-adhesion molecule, L1, forms an adhesion complex at the cell membrane containing both signaling molecules and cytoskeletal proteins. This complex mediates the transduction of extracellular signals and generates actin-mediated traction forces, both of which support axon outgrowth. The L1 cytoplasmic region binds ezrin, an adapter protein that interacts with the actin cytoskeleton. In this study, we analyzed L1-ezrin interactions in detail, assessed their role in generating traction forces by L1, and identified potential regulatory mechanisms controlling ezrin-L1 interactions. The FERM domain of ezrin binds to the juxtamembrane region of L1, demonstrated by yeast two-hybrid interaction traps and protein binding analyses in vitro. A lysine-to-leucine substitution in this domain of L1 (K1147L) shows reduced binding to the ezrin FERM domain. Additionally, in ND7 cells, the K1147L mutation inhibits retrograde movement of L1 on the cell surface that has been linked to the generation of the traction forces necessary for axon growth. A membrane-permeable peptide consisting of the juxtamembrane region of L1 that can disrupt endogenous L1-ezrin interactions inhibits neurite extension of cerebellar cells on L1 substrates. Moreover, the L1-ezrin interactions can be modulated by tyrosine phosphorylation of the L1 cytoplasmic region, namely, Y1151, possibly through Src-family kinases. Replacement of this tyrosine together with Y1176 with either aspartate or phenylalanine changes ezrin binding and alters colocalization with ezrin in ND7 cells. Collectively, these data suggest that L1-ezrin interactions mediated by the L1 juxtamembrane region are involved in traction-force generation and can be regulated by the phosphorylation of L1. (c) 2008 Wiley-Liss, Inc.

  10. Outcomes of microscope-integrated intraoperative optical coherence tomography-guided center-sparing internal limiting membrane peeling for myopic traction maculopathy: a novel technique.

    PubMed

    Kumar, Atul; Ravani, Raghav; Mehta, Aditi; Simakurthy, Sriram; Dhull, Chirakshi

    2017-07-04

    To evaluate the outcomes of pars plana vitrectomy (PPV) with microscope-integrated intraoperative optical coherence tomography (I-OCT)-guided traction removal and center-sparing internal limiting membrane (cs-ILM) peeling. Nine eyes with myopic traction maculopathy as diagnosed on SD-OCT underwent PPV with I-OCT-guided cs-ILM peeling and were evaluated prospectively for resolution of central macular thickness (CMT) and improvement in best-corrected visual acuity (BCVA), and complications, if any, were noted. All patients were followed up for more than 9 months. Resolution of the macular retinoschisis was seen in all nine eyes on SD-OCT. At 36 weeks, there was a significant improvement in mean BCVA from the preoperative BCVA (P = 0.0089) along with a reduction in the CMT from 569.77 ± 263.19 to 166.0 ± 43.91 um (P = 0.0039). None of the eyes showed worsening of BCVA or development of full-thickness macular hole in the intraoperative or follow-up period. PPV with I-OCT-guided cs-ILM peeling helps in complete removal of traction, resolution of retinoschisis and good functional recovery with low intraoperative and postoperative complications.

  11. Equivalent model and power flow model for electric railway traction network

    NASA Astrophysics Data System (ADS)

    Wang, Feng

    2018-05-01

    An equivalent model of the Cable Traction Network (CTN) considering the distributed capacitance effect of the cable system is proposed. The model can be divided into 110kV side and 27.5kV side two kinds. The 110kV side equivalent model can be used to calculate the power supply capacity of the CTN. The 27.5kV side equivalent model can be used to solve the voltage of the catenary. Based on the equivalent simplified model of CTN, the power flow model of CTN which involves the reactive power compensation coefficient and the interaction of voltage and current, is derived.

  12. Probing for exoplanets hiding in dusty debris disks: Disk imaging, characterization, and exploration with HST/STIS multi-roll coronagraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, Glenn; Hinz, Phillip M.; Grady, Carol A.

    Spatially resolved scattered-light images of circumstellar debris in exoplanetary systems constrain the physical properties and orbits of the dust particles in these systems. They also inform on co-orbiting (but unseen) planets, the systemic architectures, and forces perturbing the starlight-scattering circumstellar material. Using Hubble Space Telescope (HST)/Space Telescope Imaging Spectrograph (STIS) broadband optical coronagraphy, we have completed the observational phase of a program to study the spatial distribution of dust in a sample of 10 circumstellar debris systems and 1 'mature' protoplanetrary disk, all with HST pedigree, using point-spread-function-subtracted multi-roll coronagraphy. These observations probe stellocentric distances ≥5 AU for the nearestmore » systems, and simultaneously resolve disk substructures well beyond corresponding to the giant planet and Kuiper Belt regions within our own solar system. They also disclose diffuse very low-surface-brightness dust at larger stellocentric distances. Herein we present new results inclusive of fainter disks such as HD 92945 (F {sub disk}/F {sub star} = 5 × 10{sup –5}), confirming, and better revealing, the existence of a narrow inner debris ring within a larger diffuse dust disk. Other disks with ring-like substructures and significant asymmetries and complex morphologies include HD 181327, for which we posit a spray of ejecta from a recent massive collision in an exo-Kuiper Belt; HD 61005, suggested to be interacting with the local interstellar medium; and HD 15115 and HD 32297, also discussed in the context of putative environmental interactions. These disks and HD 15745 suggest that debris system evolution cannot be treated in isolation. For AU Mic's edge-on disk, we find out-of-plane surface brightness asymmetries at ≥5 AU that may implicate the existence of one or more planetary perturbers. Time-resolved images of the MP Mus protoplanetary disk provide spatially resolved temporal

  13. Orthodontic Management with Traction and Asymmetric Extraction for Multiple Impacted Permanent Maxillary Teeth - A Case Report.

    PubMed

    Niu, Qiannan; Zhang, Liang; Dai, Juan; Li, Feifei; Feng, Xue

    2016-01-01

    Multiple impacted teeth are a rare eruption disturbance that increases the case complexity. In this article, we described a 13-year-old boy whose 5 permanent maxillary teeth were not erupted although their root formation was complete. The orthodontic treatment with traction and asymmetric extraction was performed to achieve a significantly improved functional and esthetic result.

  14. [SCREW-BASED INTERMAXILLARY TRACTION COMBINED WITH OCCLUSAL SPLINT FOR TREATMENT OF PEDIATRIC MANDIBULAR CONDYLAR FRACTURE].

    PubMed

    Wu, Yang; Long, Xing; Deng, Mohong; Cai, Hengxing; Meng, Qinggong; Li, Bo

    2015-04-01

    To evaluate the effectiveness of the screw-based intermaxillary traction combined with occlusal splint in the treatment of pediatric mandibular condylar fracture. Between June 2005 and December 2013, 35 pediatric patients with 49 mandibular condylar fractures were treated, and the clinical data were retrospectively reviewed. There were 25 boys and 10 girls, aged 3-13 years (mean, 7.3 years). The injury causes included falling (18 cases), traffic accident (14 cases), and violence (3 cases). The time between injury and treatment was 2-30 days (mean, 6.8 days). Restricted mouth opening was observed, and the maximal mouth opening was (22.74 +/- 7.22) mm except 3 patients who were too young to measure. Condylar fractures were located at the left (12 cases), at the right (9 cases), at bilateral (14 cases) based on the sites; and fractures were classified as intracapsular (35 fractures), neck (10 fractures), and subcondylar (4 fractures) based on the fracture line. Four self-drilling titanium screws were inserted into the alveolar bone of both maxilla and mandible. After screw inserting, an occlusal splint with a fulcrum was used on the affected side and elastic band was put to perform anterior intermaxillary traction. After 1 month, the screws and splint were removed. Follow-up examinations were carried out on schedule. All the patients were followed up from 6 months to 8 years and 10 months (median, 71 months). No screw-related complication occurred in the others except one case of screw loosening. The postoperative maximal mouth opening was (38.82 +/- 2.02) nim. Mild joint noise was found in 4 cases and opening deviation occurred in 6 cases. Radiographic results demonstrated complete condyle remodeling was achieved in 24 cases (32 fractures), and moderate remodeling in 11 cases (17 fractures) at last follow-up. The screw-based intermaxillary traction combined with occlusal splint might be an effective method for pediatric mandibular condylar fracture. The screw

  15. Laboratory testing of the (Japan Storage Battery) traction batteries GS E75A and GS E150H

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report describes the testing of the GS E75A and GS E150H flooded lead-acid 12-volt traction batteries and compares the selected batteries to U.S.-made electric vehicle batteries. The results and conclusions of the testing are presented.

  16. Treatment of Skin Depression with Combined Upward Suture Traction and Percutaneous Subcision

    PubMed Central

    Bins-Ely, Jorge; Paulo, Elizabeth Machado; Lee, Kuang Hee

    2015-01-01

    Background: Scar retraction and soft-tissue depression may compromise aesthetics and cause social embarrassment. The purpose of this study was to evaluate the results of treating soft-tissue depressions or retractions at varied anatomy regions with combined upward suture traction and percutaneous subcision. Methods: There were 40 patients (age: mean, 39 years; range, 22–55 years; 39 women and 1 man) (total, 77 soft-tissue lesions) who had treatment with the present technique from 1996 to 2013. Postoperative follow-up was from 6 months to 2 years. The treated anatomic areas were evaluated in 5 groups: (1) face (8 patients; 8 lesions); (2) gluteal (16 patients; 46 lesions); (3) breast (7 patients; 10 lesions); (4) abdomen (7 patients; 7 lesions); and (5) lower limb (2 patients; 6 lesions). The technique included placing a 2-0 nylon monofilament suture deep at the core of the depression, pulling vertically up with the suture, and using a needle or miniblade (placed percutaneously or through a small incision) to release the adhesions. Results: The depressions were released successfully in all patients. Bruises around treated areas persisted for 2–3 weeks. Moderate induration persisted until 3 months. In the gluteal region, 6 patients who had retracted areas with diameter >5 cm developed seroma after treatment; the seromas resolved after needle aspiration or placement of a Penrose drain for 2 weeks (2 patients). Conclusion: The present results confirmed the efficacy of the combined subcision method with upward traction at diverse body sites as previously reported for inverted nipple in the breast. PMID:26579340

  17. Behavior of single lap composite bolted joint under traction loading: Experimental investigation

    NASA Astrophysics Data System (ADS)

    Awadhani, L. V.; Bewoor, Anand

    2018-04-01

    Composite bolted joints are preferred connection in the composite structures to facilitate the dismantling for the replacements/ maintenance work. The joint behavior under tractive forces has been studied in order to understand the safety of the structure designed. The main objective of this paper is to investigate the behavior of single-lap joints in carbon fiber reinforced epoxy composites under traction loading conditions. The experiments were designed to identify the effect of bolt diameter, stacking sequence and loading rate on the properties of the joint. The experimental results show that the parameters influence the joint performance significantly.

  18. Effects of segmental traction therapy on lumbar disc herniation in patients with acute low back pain measured by magnetic resonance imaging: A single arm clinical trial.

    PubMed

    Karimi, Noureddin; Akbarov, Parvin; Rahnama, Leila

    2017-01-01

    Low Back Pain (LBP) is considered as one of the most frequent disorders, which about 80% of adults experience in their lives. Lumbar disc herniation (LDH) is a cause for acute LBP. Among conservative treatments, traction is frequently used by clinicians to manage LBP resulting from LDH. However, there is still a lack of consensus about its efficacy. The purpose of this study was to evaluate the effects of segmental traction therapy on lumbar discs herniation, pain, lumbar range of motion (ROM), and back extensor muscles endurance in patients with acute LBP induced by LDH. Fifteen patients with acute LBP diagnosed by LDH participated in the present study. Participants undertook 15 sessions of segmental traction therapy along with conventional physiotherapy, 5 times a week for 3 weeks. Lumbar herniated mass size was measured before and after the treatment protocol using magnetic resonance imaging. Furthermore, pain, lumbar ROM and back muscle endurance were evaluated before and after the procedure using clinical outcome measures. Following the treatment protocol, herniated mass size and patients' pain were reduced significantly. In addition, lumbar flexion ROM showed a significant improvement. However, no significant change was observed for back extensor muscle endurance after the treatment procedure. The result of the present study showed segmental traction therapy might play an important role in the treatment of acute LBP stimulated by LDH.

  19. Using real-time ultrasound imaging as adjunct teaching tools to enhance physical therapist students' ability and confidence to perform traction of the knee joint.

    PubMed

    Markowski, Alycia; Watkins, Maureen K; Burnett, Todd; Ho, Melissa; Ling, Michael

    2018-04-01

    Often, physical therapy students struggle with the skill and the confidence to perform manual techniques for musculoskeletal examination. Current teaching methods lack concurrent objective feedback. Real-time ultrasound imaging (RTUI) has the advantage of generating visualization of anatomical structures in real-time in an efficient and safe manner. We hypothesize that the use of RTUI to augment teaching with concurrent objective visual feedback will result in students' improved ability to create a change in joint space when performing a manual knee traction and higher confidence scores. Eighty-six students were randomly allocated to a control or an experimental group. All participants received baseline instructions on how to perform knee traction. The control group received standardized lab instruction (visual, video, and instructor/partner feedback). The experimental group received standardized lab instruction augmented with RTUI feedback. Pre-data and post-data collection consisted of measuring participants' ability to create changes in joint space when performing knee traction, a confidence survey evaluating perceived ability and a reflection paper. Joint space changes between groups were compared using a paired t-test. Surveys were analyzed with descriptive statistics and compared using Wilcoxon Rank Sum and for the reflection papers, themes were identified and descriptive statistics reported. Although there were no statistically significant differences between the control and the experimental group, overall scores improved. Qualitative data suggests students found the use of ultrasound imaging beneficial and would like more exposure. This novel approach to teaching knee traction with RTUI has potential and may be a basis for further studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Investigation of induction motor temperature distribution in traction applications

    NASA Astrophysics Data System (ADS)

    Pugachev, A. A.; Kosmodamianskiy, A. S.

    2017-10-01

    The relevance of thermal behavior investigation of traction induction motors is shown. The brief survey of techniques to monitor the temperature of an induction motors is carried out. The detailed multi-node equivalent thermal circuit of an induction motor is designed for steady state. The calculation technique of some units’ thermal resistances by using of construction features and geometric sizes of an induction motor is shown. Results of thermal processes calculation for 14 kWAO-63-4 induction motor are shown. The adequacy of proposed thermal model is proved by means of good convergence of calculated results with the results obtained by the experimental investigation on the same induction motor. As a result of investigation, it is established that the slot winding of the stator located about on 2/3 of its length from the cooling air entrance has the highest value of temperature.

  1. Economic Effects of Fascioliasis on Animal Traction Technology in Adamawa State, Nigeria

    NASA Astrophysics Data System (ADS)

    Jaafar-Furo, M. R.; Mshelia, S. I.; Suleiman, A.

    This study reports the results of a survey conducted in 2001 to investigate the economic effects of Fascioliasis (Liverflukes) on drought animals in Adamawa State, Nigeria. Data were collected from 60 and 74 farmers` owners of 148 non-infested and 204 infested drought animals, respectively, through a cost-route method using structured questionnaires and supplemented with interviews. Analysis using descriptive statistics and animal traction efficiency measure showed that the non-infested drought animals were efficiently utilized than the infested drought animals. It was concluded that the non-infested drought animals were more productive. The study therefore, recommend among others, the regular deworming of drought animals in order to improve their efficiency.

  2. Review on the Traction System Sensor Technology of a Rail Transit Train.

    PubMed

    Feng, Jianghua; Xu, Junfeng; Liao, Wu; Liu, Yong

    2017-06-11

    The development of high-speed intelligent rail transit has increased the number of sensors applied on trains. These play an important role in train state control and monitoring. These sensors generally work in a severe environment, so the key problem for sensor data acquisition is to ensure data accuracy and reliability. In this paper, we follow the sequence of sensor signal flow, present sensor signal sensing technology, sensor data acquisition, and processing technology, as well as sensor fault diagnosis technology based on the voltage, current, speed, and temperature sensors which are commonly used in train traction systems. Finally, intelligent sensors and future research directions of rail transit train sensors are discussed.

  3. Traction suture modification to tongue-in-groove caudal septoplasty.

    PubMed

    Indeyeva, Y A; Lee, T S; Gordin, E; Chan, D; Ducic, Y

    2018-02-01

    Caudal septal deviation leads to unfavorable esthetic as well as functional effects on the nasal airway. A modification to the tongue-in-groove (TIG) technique to correct these caudal septal deformities is described. With placement of a temporary suspension suture to the caudal septum, manual traction is applied, assuring that the caudal septum remains in the midline position while it is being secured with multiple through-and-through, trans-columellar and trans-septal sutures. From 2003 to 2016, 148 patients underwent endonasal septoplasty using this modified technique, with excellent functional and cosmetic outcomes and a revision rate of 1.4%. This modified TIG technique replaces the periosteal suture that secures the caudal septum to the midline nasal crest in the original TIG technique. This simplifies the procedure and minimizes the risk of securing the caudal septum off-midline when used in endonasal septoplasty. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Hoffmann-reflex is delayed during 6 degree head-down tilt with balanced traction

    NASA Technical Reports Server (NTRS)

    Haruna, Y.; Styf, J. R.; Kahan, N.; Hargens, A. R.

    1999-01-01

    BACKGROUND: Increased spinal height due to the lack of of axial compression on spinal structures in microgravity may stretch the spinal cord, cauda equina, nerve roots, and paraspinal tissues. HYPOTHESIS: Exposure to simulated microgravity causes dysfunction of nerve roots so that the synaptic portion of the Achilles tendon reflex is delayed. METHODS: Six healthy male subjects were randomly divided into two groups with three in each group. The subjects in the first group underwent horizontal bed rest (HBR) for three days. After a two week interval they underwent bed rest in a position of head-down tilt with balanced traction (HDT). So that each subject could serve as his own control, the second group was treated identically but in opposite order. Bilateral F waves and H-reflexes were measured daily (18:30-20:30) on all subjects placed in a prone position. RESULTS: By means of ANOVA, differences between HDT and HBR were observed only in M-latency and F-ratio, not in F-latency, central latency, and H-latency. Differences during the course of the bed rest were observed in M-latency and H-latency only. Tibial H latency was significantly lengthened in HDT group on day 2 and 3, although no significant difference between HDT and HBR was observed. CONCLUSION: The monosynaptic reflex assessed by H-reflex was delayed during 6 degree HDT with traction. The exact mechanism of this delay and whether the change was due to lengthening of the lower part of the vertebrae remain to be clarified.

  5. Camouflage treatment for class III malocclusion combined with traction of an impacted maxillary central incisor.

    PubMed

    Closs, Luciane Quadrado; Mundstock, Karina Santos; Ribeiro, Darlene Santos; Reston, Eduardo Galia; Silva, Aurelício Novaes

    2010-01-01

    This case report describes the treatment of a patient with an unerupted maxillary left central incisor, class III malocclusion with crossbite of the maxillary posterior teeth and lateral open bite. Treatment consisted of rapid maxillary expansion followed by anterior space opening, maxillary protraction and traction of the unerupted teeth with a light force system. Favorable results were obtained in terms of correcting incisor position and class III malocclusion. The results achieved remained stable throughout a 4-year retention period.

  6. Traction force microscopy of engineered cardiac tissues.

    PubMed

    Pasqualini, Francesco Silvio; Agarwal, Ashutosh; O'Connor, Blakely Bussie; Liu, Qihan; Sheehy, Sean P; Parker, Kevin Kit

    2018-01-01

    Cardiac tissue development and pathology have been shown to depend sensitively on microenvironmental mechanical factors, such as extracellular matrix stiffness, in both in vivo and in vitro systems. We present a novel quantitative approach to assess cardiac structure and function by extending the classical traction force microscopy technique to tissue-level preparations. Using this system, we investigated the relationship between contractile proficiency and metabolism in neonate rat ventricular myocytes (NRVM) cultured on gels with stiffness mimicking soft immature (1 kPa), normal healthy (13 kPa), and stiff diseased (90 kPa) cardiac microenvironments. We found that tissues engineered on the softest gels generated the least amount of stress and had the smallest work output. Conversely, cardiomyocytes in tissues engineered on healthy- and disease-mimicking gels generated significantly higher stresses, with the maximal contractile work measured in NRVM engineered on gels of normal stiffness. Interestingly, although tissues on soft gels exhibited poor stress generation and work production, their basal metabolic respiration rate was significantly more elevated than in other groups, suggesting a highly ineffective coupling between energy production and contractile work output. Our novel platform can thus be utilized to quantitatively assess the mechanotransduction pathways that initiate tissue-level structural and functional remodeling in response to substrate stiffness.

  7. Keratocytes generate traction forces in two phases.

    PubMed

    Burton, K; Park, J H; Taylor, D L

    1999-11-01

    Forces generated by goldfish keratocytes and Swiss 3T3 fibroblasts have been measured with nanonewton precision and submicrometer spatial resolution. Differential interference contrast microscopy was used to visualize deformations produced by traction forces in elastic substrata, and interference reflection microscopy revealed sites of cell-substratum adhesions. Force ranged from a few nanonewtons at submicrometer spots under the lamellipodium to several hundred nanonewtons under the cell body. As cells moved forward, centripetal forces were applied by lamellipodia at sites that remained stationary on the substratum. Force increased and abruptly became lateral at the boundary of the lamellipodium and the cell body. When the cell retracted at its posterior margin, cell-substratum contact area decreased more rapidly than force, so that stress (force divided by area) increased as the cell pulled away. An increase in lateral force was associated with widening of the cell body. These mechanical data suggest an integrated, two-phase mechanism of cell motility: (1) low forces in the lamellipodium are applied in the direction of cortical flow and cause the cell body to be pulled forward; and (2) a component of force at the flanks pulls the rear margins forward toward the advancing cell body, whereas a large lateral component contributes to detachment of adhesions without greatly perturbing forward movement.

  8. The influence of battery degradation level on the selected traction parameters of a light-duty electric vehicle

    NASA Astrophysics Data System (ADS)

    Juda, Z.; Noga, M.

    2016-09-01

    The article describes results of an analysis of the impact of degradation level of battery made in lead-acid technology on selected traction parameters of an electric light duty vehicle. Lead-acid batteries are still used in these types of vehicles. They do not require complex systems of performance management and monitoring and are easy to maintaining. Despite the basic disadvantage, which is the low value of energy density, low price is a decisive factor for their use in low-speed electric vehicles. The process of aging of the battery related with an increase in internal resistance of the cells and the loss of electric capacity of the battery was considered. A simplified model of cooperation of the DC electric motor with the battery assuming increased internal resistance was presented. In the paper the results of comparative traction research of the light-duty vehicle equipped with a set of new batteries and set of batteries having a significant degradation level were showed. The analysis of obtained results showed that the correct exploitation of the battery can slow down the processes of degradation and, thus, extend battery life cycle.

  9. Review on the Traction System Sensor Technology of a Rail Transit Train

    PubMed Central

    Feng, Jianghua; Xu, Junfeng; Liao, Wu; Liu, Yong

    2017-01-01

    The development of high-speed intelligent rail transit has increased the number of sensors applied on trains. These play an important role in train state control and monitoring. These sensors generally work in a severe environment, so the key problem for sensor data acquisition is to ensure data accuracy and reliability. In this paper, we follow the sequence of sensor signal flow, present sensor signal sensing technology, sensor data acquisition, and processing technology, as well as sensor fault diagnosis technology based on the voltage, current, speed, and temperature sensors which are commonly used in train traction systems. Finally, intelligent sensors and future research directions of rail transit train sensors are discussed. PMID:28604615

  10. The effects of infrared laser therapy and weightbath traction hydrotherapy as components of complex physical treatment in disorders of the lumbar spine: a controlled pilot study with follow-up

    NASA Astrophysics Data System (ADS)

    Oláh, Csaba; Oláh, Mihály; Demeter, Béla; Jancsó, Zoltán; Páll, Valéria; Bender, Tamás

    2010-02-01

    Introduction: The therapeutic modalities available for the conservative management of chronic lumbar pain included infrared laser therapy and underwater traction, which usefulness is not universally acknowledged. This study was intended to ascertain any beneficial impact of infrared laser therapy and weightbath treatment on the clinical parameters and quality of life of patients with lumbar discopathy. Material and methods: The study population comprised 54 randomised subjects. I. group of 18 patents received only infrared laser therapy to lumbar region and painful Valley points. II. group of 18 subjects each received underwater traction therapy of lumbar spine with add-on McKenzie exercise and iontophoresis. The remaining III. group treated with exercise and iontophoresis, served as control. VAS, Oswestry index, SF36 scores, range of motion, neurological findings and thermography were monitored to appraise therapeutic afficacy in lumbar discopathy. A CT or MRI scan was done at baseline and after 3 months follow-up. Result:Infrared laser therapy and underwater traction for discopathy achieved significant improvement of all study parameters, which was evident 3 months later. Among the controls, significant improvement of only a single parameter was seen in patients with lumbar discopathy. Conclusions: Infrared laser therapy and underwater traction treatment effectively mitigate pain, muscle spasms, enhance joint flexibility, and improve the quality of life of patients with lumbar discopathy.

  11. Traction-free vibrations of finite trigonal elastic cylinders.

    PubMed

    Heyliger, Paul R; Johnson, Ward L

    2003-04-01

    The unrestrained, traction-free vibrations of finite elastic cylinders with trigonal material symmetry are studied using two approaches, based on the Ritz method, which formulate the weak form of the equations of motion in cylindrical and rectangular coordinates. Elements of group theory are used to divide approximation functions into orthogonal subsets, thus reducing the size of the computational problem and classifying the general symmetries of the vibrational modes. Results for the special case of an isotropic cylinder are presented and compared with values published by other researchers. For the isotropic case, the relative accuracy of the formulations in cylindrical and rectangular coordinates can be evaluated, because exact analytical solutions are known for the torsional modes. The calculation in cylindrical coordinates is found to be more accurate for a given number of terms in the series approximation functions. For a representative trigonal material, langatate, calculations of the resonant frequencies and the sensitivity of the frequencies on each of the elastic constants are presented. The dependence on geometry (ratio of length to diameter) is briefly explored. The special case of a transversely isotropic cylinder (with the elastic stiffness C14 equal to zero) is also considered.

  12. Traction-drive, seven-degree-of-freedom telerobot arm: A concept for manipulaton in space

    NASA Technical Reports Server (NTRS)

    Kuban, D. P.; Williams, D. M.

    1987-01-01

    As man seeks to expand his dominion into new environments, the demand increases for machines that perform useful functions in remote locations. This new concept for manipulation in space is based on knowledge and experience gained from manipulator systems developed to meet the needs of remote nuclear applications. It merges the best characteristics of teleoperation and robotic technologies. The design goals for the telerobot, a mechanical description, and technology areas that must be addressed for successful implementation are presented and discussed. The concept incorporates mechanical traction drives, redundant kinematics, and modular arm subelements to provide a backlash-free manipulator capable of obstacle avoidance.

  13. Debris Disk Structure and Morphology as Revealed by Aggressive STIS Multi-Roll Coronagraphy: A New Look at Some Old Friends

    NASA Technical Reports Server (NTRS)

    Grady, Carol A; Kuchner, Marc; Woodgate, Bruce E.

    2012-01-01

    We present new imaging results from a well-selected sample of II circumstellar debris disks, all with HST pedigree, using STIS visible-light 6-roll PSF-template subtracted coronagraphy (PSFTSC). These new observations, pushing HST to its highest levels of coronagraphic performance, simultaneously probe both the interior regions of these debris systems, with inner working distances < app 8 AU for half the stars in this sample (corresponding to the giant planet and Kuiper belt regions within our own solar system), and the exterior regions far beyond. These new images enable direct inter-comparison of the architectures of these exoplanetary debris systems in the context of our own Solar System: These observations also permit us, for the first time, to characterize material in these regions at high spatial resolution and identify disk sub-structures that are signposts of planet formation and evolution; in particular, asymmetries and non-uniform debris structures that signal the presence of co-orbiting perturbing planets, and dynamical interactions (e.g., resulting in posited small grain stripping and disk "pollution") with the ISM. We focus here on recently acquired and reduced images of he circumstellar debris systems about: AU Mic (edge-on, and @ 10 pc the closest star in our sample), HD 61005, HD 32297 and HD 15115 (all with morphologies strongly suggestive of ISM wind interactions), HD 181327 & HDI07146 (close to face-on with respectively narrow and broad debris rings), and MP Mus (a "mature" proto-planetary disk hosted by a cTTS). All of our objects were previously observed in the near-IR with inferior spatial resolution and imaging efficacy, but with NICMOS r = 0.3" inner working angle (IWA) comparable to STIS multi-roll coronagraphy. The combination of new optical and existing near-IR imaging can strongly constrain the dust properties, thus enabling an assessment of grain processing and planetesimal populations. These results will directly inform upon the

  14. Evaluation of traction stirrup distraction technique to increase the joint space of the shoulder joint in the dog: A cadaveric study.

    PubMed

    Devesa, V; Rovesti, G L; Urrutia, P G; Sanroman, F; Rodriguez-Quiros, J

    2015-06-01

    The objective of this study was to evaluate technical feasibility and efficacy of a joint distraction technique by traction stirrup to facilitate shoulder arthroscopy and assess potential soft tissue damage. Twenty shoulders were evaluated radiographically before distraction. Distraction was applied with loads from 40 N up to 200 N, in 40 N increments, and the joint space was recorded at each step by radiographic images. The effects of joint flexion and intra-articular air injection at maximum load were evaluated. Radiographic evaluation was performed after distraction to evaluate ensuing joint laxity. Joint distraction by traction stirrup technique produces a significant increase in the joint space; an increase in joint laxity could not be inferred by standard and stress radiographs. However, further clinical studies are required to evaluate potential neurovascular complications. A wider joint space may be useful to facilitate arthroscopy, reducing the likelihood for iatrogenic damage to intra-articular structures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Rupture dynamics along bimaterial interfaces: a parametric study of the coupling between interfacial sliding and normal traction perturbation

    NASA Astrophysics Data System (ADS)

    Scala, Antonio; Festa, Gaetano; Vilotte, Jean-Pierre

    2017-04-01

    Earthquake ruptures often develop along faults separating materials with dissimilar elastic properties. Due to the broken symmetry, the propagation of the rupture along the bimaterial interface is driven by the coupling between interfacial sliding and normal traction perturbations. We numerically investigate in-plane rupture growth along a planar interface, under slip weakening friction, separating two dissimilar isotropic linearly elastic half-spaces. We perform a parametric study of the classical Prakash-Clifton regularisation for different material contrasts. In particular mesh-dependence and regularisation-dependence of the numerical solutions are analysed in this parameter space. When regularisation involves a slip-rate dependent relaxation time, a characteristic sliding distance is identified below which numerical solutions no longer depend on the regularisation parameter, i.e. they are consistent solutions of the same physical problem. Such regularisation provides an adaptive high-frequency filter of the slip-induced normal traction perturbations, following the dynamic shrinking of the dissipation zone during the acceleration phase. In contrast, regularisation involving a constant relaxation time leads to numerical solutions that always depend on the regularisation parameter since it fails adapting to the shrinking of the process zone. Dynamic regularisation is further investigated using a non-local regularisation based on a relaxation time that depends on the dynamic length of the dissipation zone. Such reformulation is shown to provide similar results as the dynamic time scale regularisation proposed by Prakash-Clifton when slip rate is replaced by the maximum slip rate along the sliding interface. This leads to the identification of a dissipative length scale associated with the coupling between interfacial sliding and normal traction perturbations, together with a scaling law between the maximum slip rate and the dynamic size of the process zone during

  16. Two-Layer Elastographic 3-D Traction Force Microscopy

    PubMed Central

    Álvarez-González, Begoña; Zhang, Shun; Gómez-González, Manuel; Meili, Ruedi; Firtel, Richard A.; Lasheras, Juan C.; del Álamo, Juan C.

    2017-01-01

    Cellular traction force microscopy (TFM) requires knowledge of the mechanical properties of the substratum where the cells adhere to calculate cell-generated forces from measurements of substratum deformation. Polymer-based hydrogels are broadly used for TFM due to their linearly elastic behavior in the range of measured deformations. However, the calculated stresses, particularly their spatial patterns, can be highly sensitive to the substratum’s Poisson’s ratio. We present two-layer elastographic TFM (2LETFM), a method that allows for simultaneously measuring the Poisson’s ratio of the substratum while also determining the cell-generated forces. The new method exploits the analytical solution of the elastostatic equation and deformation measurements from two layers of the substratum. We perform an in silico analysis of 2LETFM concluding that this technique is robust with respect to TFM experimental parameters, and remains accurate even for noisy measurement data. We also provide experimental proof of principle of 2LETFM by simultaneously measuring the stresses exerted by migrating Physarum amoeboae on the surface of polyacrylamide substrata, and the Poisson’s ratio of the substrata. The 2LETFM method could be generalized to concurrently determine the mechanical properties and cell-generated forces in more physiologically relevant extracellular environments, opening new possibilities to study cell-matrix interactions. PMID:28074837

  17. Keratocytes Generate Traction Forces in Two PhasesV⃞

    PubMed Central

    Burton, Kevin; Park, Jung H.; Taylor, D. Lansing

    1999-01-01

    Forces generated by goldfish keratocytes and Swiss 3T3 fibroblasts have been measured with nanonewton precision and submicrometer spatial resolution. Differential interference contrast microscopy was used to visualize deformations produced by traction forces in elastic substrata, and interference reflection microscopy revealed sites of cell-substratum adhesions. Force ranged from a few nanonewtons at submicrometer spots under the lamellipodium to several hundred nanonewtons under the cell body. As cells moved forward, centripetal forces were applied by lamellipodia at sites that remained stationary on the substratum. Force increased and abruptly became lateral at the boundary of the lamellipodium and the cell body. When the cell retracted at its posterior margin, cell-substratum contact area decreased more rapidly than force, so that stress (force divided by area) increased as the cell pulled away. An increase in lateral force was associated with widening of the cell body. These mechanical data suggest an integrated, two-phase mechanism of cell motility: (1) low forces in the lamellipodium are applied in the direction of cortical flow and cause the cell body to be pulled forward; and (2) a component of force at the flanks pulls the rear margins forward toward the advancing cell body, whereas a large lateral component contributes to detachment of adhesions without greatly perturbing forward movement. PMID:10564269

  18. Abdominal wall integrity after open abdomen: long-term results of vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM).

    PubMed

    Willms, A; Schaaf, S; Schwab, R; Richardsen, I; Bieler, D; Wagner, B; Güsgen, C

    2016-12-01

    The open abdomen has become a standard technique in the management of critically ill patients undergoing surgery for severe intra-abdominal conditions. Negative pressure and mesh-mediated fascial traction are commonly used and achieve low fistula rates and high fascial closure rates. In this study, long-term results of a standardised treatment approach are presented. Fifty-five patients who underwent OA management for different indications at our institution from 2006 to 2013 were enrolled. All patients were treated under a standardised algorithm that uses a combination of vacuum-assisted wound closure and mesh-mediated fascial traction. Structured follow-up assessments were offered to patients and included a medical history, a clinical examination and abdominal ultrasonography. The data obtained were statistically analysed. The fascial closure rate was 74 % in an intention-to-treat analysis and 89 % in a per-protocol analysis. The fistula rate was 1.8 %. Thirty-four patients attended follow-up. The median follow-up was 46 months (range 12-88 months). Incisional hernias developed in 35 %. Patients with hernias needed more operative procedures (10.3 vs 3.4, p = 0.03) than patients without hernia formation. A Patient Observer Scar Assessment Scale (POSAS) of 31.1 was calculated. Patients with symptomatic hernias (NAS of 2-10) had a significantly lower mean POSAS score (p = 0.04). Vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) seem to result in low complication rates and high fascial closure rates. Abdominal wall reconstruction, which is a challenging and complex procedure and causes considerable patient discomfort, can thus be avoided in the majority of cases. Available results are based on studies involving only a small number of cases. Multi-centre studies and registry-based data are therefore needed to validate these findings.

  19. Modified Longo's stapled hemorrhoidopexy with additional traction sutures for the treatment of residual prolapsed piles.

    PubMed

    Chen, Chuang-Wei; Kang, Jung-Cheng; Wu, Chang-Chieh; Hsiao, Cheng-Wen; Jao, Shu-Wen

    2008-03-01

    Residual prolapsed piles is a problem after the stapled hemorrhoidopexy, especially in large third- or fourth-degree hemorrhoids. We have developed a method using additional traction sutures along with modified Longo's procedure to manage this problem. From January 2005 to October 2005, 30 consecutive patients with symptomatic third- or fourth-degree hemorrhoids who underwent the modified Longo's stapled hemorrhoidopexy with additional traction sutures in a single institution were collected. The demographics, postoperative pain score, surgical features, outcomes, and early and late complications were recorded. All patients were followed for a mean duration of 8.8 (range, 4-15) months. Thirty patients (17 males) with a mean age of 45 (range, 27-63) years were identified. The mean postoperative pain score on the morning of the first postoperative day was 2.8 (range, 1-4). The mean duration of operation was 30.7 (range, 25-37) min. The mean duration of hospital stay was 2 (range, 1-3) days. The mean days for patients to resume normal work was 6.7 (range, 4-9) days. No other procedure-related complications occurred in all patients. There was no early complication except for fecal urgency found in one patient during the first postoperative days. Regarding the late complications, no residual prolapsed piles, persistent anal pain, incontinence, anal stenosis, or recurrent symptoms were found. Our preliminary experiences indicated that this modified procedures truly contributed to reduce the residual internal hemorrhoids and maintained the benefits of stapled hemorrhoidopexy. Randomized trial and long-term follow-up warrant to determine possible surgical and functional outcome.

  20. A randomized clinical trial of the effectiveness of mechanical traction for sub-groups of patients with low back pain: study methods and rationale

    PubMed Central

    2010-01-01

    Background Patients with signs of nerve root irritation represent a sub-group of those with low back pain who are at increased risk of persistent symptoms and progression to costly and invasive management strategies including surgery. A period of non-surgical management is recommended for most patients, but there is little evidence to guide non-surgical decision-making. We conducted a preliminary study examining the effectiveness of a treatment protocol of mechanical traction with extension-oriented activities for patients with low back pain and signs of nerve root irritation. The results suggested this approach may be effective, particularly in a more specific sub-group of patients. The aim of this study will be to examine the effectiveness of treatment that includes traction for patients with low back pain and signs of nerve root irritation, and within the pre-defined sub-group. Methods/Design The study will recruit 120 patients with low back pain and signs of nerve root irritation. Patients will be randomized to receive an extension-oriented treatment approach, with or without the addition of mechanical traction. Randomization will be stratified based on the presence of the pre-defined sub-grouping criteria. All patients will receive 12 physical therapy treatment sessions over 6 weeks. Follow-up assessments will occur after 6 weeks, 6 months, and 1 year. The primary outcome will be disability measured with a modified Oswestry questionnaire. Secondary outcomes will include self-reports of low back and leg pain intensity, quality of life, global rating of improvement, additional healthcare utilization, and work absence. Statistical analysis will be based on intention to treat principles and will use linear mixed model analysis to compare treatment groups, and examine the interaction between treatment and sub-grouping status. Discussion This trial will provide a methodologically rigorous evaluation of the effectiveness of using traction for patients with low back

  1. The effects of cervical traction, cranial rhythmic impulse, and Mckenzie exercise on headache and cervical muscle stiffness in episodic tension-type headache patients.

    PubMed

    Choi, Sung-Yong; Choi, Jung-Hyun

    2016-03-01

    [Purpose] The purpose of this study was to examine the effects of cervical traction treatment, cranial rhythmic impulse treatment, a manual therapy, and McKenzie exercise, a dynamic strengthening exercise, on patients who have the neck muscle stiffness of the infrequent episodic tension-type (IETTH) headache and frequent episodic tension-type headache(FETTH), as well as to provide the basic materials for clinical interventions. [Subjects] Twenty-seven subjects (males: 15, females: 12) who were diagnosed with IETTH and FETTH after treatment by a neurologist were divided into three groups: (a cervical traction group (CTG, n=9), a cranial rhythmic contractiongroup (CRIG, n=9), and a McKenzie exercise group (MEG, n=9). An intervention was conducted for each group and the differences in their degrees of neck pain and changes in muscle tone were observed. [Results] In the within-group comparison of each group, headache significantly decreased in CTG. According to the results of the analysis of the muscle tone of the upper trapezius, there was a statistically significant difference in MEG on the right side and in CRIG on the left side. According to the results of the analysis of the muscle tone of the sternocleidomastoid muscle, there was a statistically significant difference in MEG on the right side and in CRIG on the left side. [Conclusion] In the comparison of the splenius capitis muscle between the groups, there was a statistically significant difference on the right side. Hence, compared to the other methods, cervical traction is concluded to be more effective at reducing headaches in IETTH and FETTH patients.

  2. Traction-assisted Internal Negative Pressure Wound Therapy With Bridging Retention Sutures to Facilitate Staged Closure of High-risk Wounds Under Tension.

    PubMed

    DeFazio, Michael V; Economides, James M; Anghel, Ersilia L; Mathis, Ryan K; Barbour, John R; Attinger, Christopher E

    2017-10-01

    Loss of domain often complicates attempts at delayed wound closure in regions of high tension. Wound temporization with traction-assisted internal negative pressure wound therapy (NPWT), using bridging retention sutures, can minimize the effects of edema and elastic recoil that contribute to progressive tissue retraction over time. The investigators evaluated the safety and efficacy of this technique for complex wound closure. Between May 2015 and November 2015, 18 consecutive patients underwent staged reconstruction of complex and/or contaminated soft tissue defects utilizing either conventional NPWT or modified NPWT with instillation and continuous dermatotraction via bridging retention sutures. Instillation of antimicrobial solution was reserved for wounds containing infected/exposed hardware or prosthetic devices. Demographic data, wound characteristics, reconstructive outcomes, and complications were reviewed retrospectively. Eighteen wounds were treated with traction-assisted internal NPWT using the conventional (n = 11) or modified instillation (n = 7) technique. Defects involved the lower extremity (n = 14), trunk (n = 3), and proximal upper extremity (n = 1), with positive cultures identified in 12 wounds (67%). Therapy continued for 3 to 8 days (mean, 4.3 days), resulting in an average wound surface area reduction of 78% (149 cm² vs. 33 cm²) at definitive closure. Seventeen wounds (94%) were closed directly, whereas the remaining defect required coverage with a local muscle flap and skin graft. At final follow-up (mean, 12 months), 89% of wounds remained closed. In 2 patients with delayed, recurrent periprosthetic infection (mean, 7.5 weeks), serial debridement/hardware removal mandated free tissue transfer for composite defect reconstruction. Traction-assisted internal NPWT provides a safe and effective alternative to reduce wound burden and facilitate definitive closure in cases where delayed reconstruction of high-tension wounds is planned.

  3. Scattering of antiplane shear waves by a circular cylinder in a traction-free plate

    PubMed

    Wang; Ying; Li

    2000-09-01

    Following a well-established formula used by many researchers, the scattering of an anti-plane shear wave by an infinite elastic cylinder of arbitrary relative radius centered in a traction-free two-dimensional isotropic plate has been examined. The plate is divided into three regions by introducing two imaginary planes located symmetrically away from the surface of the cylinder and perpendicular to surfaces of the plate. The wave field is expanded into cylinder wave modes in the central bounded region containing the cylinder, while the fields in the other two outer regions are expanded into plate wave modes. A system of equations determining the expansion coefficients is obtained according to the traction-free boundary conditions on the plate walls and the stress and displacement continuity conditions across the imaginary planes. By taking an appropriate finite number of terms of the infinite expansion series and a few selected points on the two properly chosen virtual planes and the surfaces of the plate through convergence and precision tests, a matrix equation to numerically evaluate the expansion coefficients is found. The method of how to choose the locations of the imaginary planes and the terms of the expansion series as well as the points on each respective boundary is given in Sec. III in detail. Curves of the reflection and transmission coefficients against the relative radius of the cylinder in welded and slip or cracked interfacial conditions are shown. Analysis on the contrast variations of the reflection and transmission coefficients for a cylinder in bonded and debonded interfacial situations is made. The relative errors estimated by the deviation of the numerical results from the principle of the conservation of energy are found to be less than 2%.

  4. Directional control of lamellipodia extension by constraining cell shape and orienting cell tractional forces

    NASA Technical Reports Server (NTRS)

    Parker, Kevin Kit; Brock, Amy Lepre; Brangwynne, Cliff; Mannix, Robert J.; Wang, Ning; Ostuni, Emanuele; Geisse, Nicholas A.; Adams, Josephine C.; Whitesides, George M.; Ingber, Donald E.

    2002-01-01

    Directed cell migration is critical for tissue morphogenesis and wound healing, but the mechanism of directional control is poorly understood. Here we show that the direction in which cells extend their leading edge can be controlled by constraining cell shape using micrometer-sized extracellular matrix (ECM) islands. When cultured on square ECM islands in the presence of motility factors, cells preferentially extended lamellipodia, filopodia, and microspikes from their corners. Square cells reoriented their stress fibers and focal adhesions so that tractional forces were concentrated in these corner regions. When cell tension was dissipated, lamellipodia extension ceased. Mechanical interactions between cells and ECM that modulate cytoskeletal tension may therefore play a key role in the control of directional cell motility.

  5. Personal equipment for low seam coal miners. 8. Improved traction rubber boot soles. Report for 1978-82

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanders, M.S.; Downing, J.V.

    1982-10-01

    Based on laboratory and preliminary field tests of off-the-shelf steel-toed rubber boots, a molded sole design was developed to provide increased traction over conventional calendared sole miners boots. The pattern provided sharp edges perpendicular to both lateral and fore-aft slip vectors. The sole was designed to reduce mud caking. An instep lace-up capability was added to better secure the foot inside the boot. A 5-month field evaluation compared the prototype boots to the boots the participants usually wear.

  6. Performance Comparison between a Permanent Magnet Synchronous Motor and an Induction Motor as a Traction Motor for High Speed Train

    NASA Astrophysics Data System (ADS)

    Kondo, Minoru; Kawamura, Junya; Terauchi, Nobuo

    Performance tests are carried out to demonstrate the superiority of a permanent magnet synchronous motor to an induction motor as a traction motor for high-speed train. A prototype motor was manufactured by replacing the rotor of a conventional induction motor. The test results show that the permanent magnet motor is lighter, efficient and more silent than the induction motor because of the different rotor structure.

  7. Immediate changes in spinal height and pain after aquatic vertical traction in patients with persistent low back symptoms: a crossover clinical trial.

    PubMed

    Simmerman, Susanne M; Sizer, Phillip S; Dedrick, Gregory S; Apte, Gail G; Brismée, Jean-Michel

    2011-05-01

    To investigate the effect of aquatic vertical traction on spinal height, pain intensity, and centralization response compared with a land-based supine flexion position for patients with low back pain and signs of nerve root compression. Single-blind, repeated-measures crossover design. Outpatient physical therapy clinic. Ninety-eight subjects were recruited using consecutive sampling, with 28 men and 32 women of a mean ± standard deviation (SD) age of 59.6 ± 11.6 years completing testing. Each subject participated in 2 sessions that consisted of loaded walking for 15 minutes, followed by either 15 minutes of land-based supine position or 15 minutes of aquatic vertical traction. Spinal height change, measured using a commercial stadiometer, was determined after completing loaded walking and after each intervention. The mean ± SD height change of 4.99 ± 2.88 mm after aquatic vertical traction was similar to that of 4.21 ± 2.53 mm after the land-based supine flexion (P = .0969). Paired t-test indicated that both interventions resulted in significant increased height (P < .0001). Decreases in pain after aquatic intervention (2.7 ± 2.1 cm) were significantly greater than decreases after land intervention (1.7 ± 1.7 cm; P = .0034), and centralization of symptoms was more pronounced after aquatic vertical suspension compared with the supine land-based flexion condition (P < .0001). A significant correlation between height change and both pain reduction (r = 0.39; P = .001) and centralization (r = 0.29; P = .013) was observed for the aquatic intervention only. Although both the aquatic and land interventions produced significant increases in overall spinal height, the aquatic intervention produced greater pain relief and centralization response in subjects with low back pain and signs of nerve root compression. Copyright © 2011 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  8. Morphological changes of the caudal cervical intervertebral foramina due to flexion-extension and compression-traction movements in the canine cervical vertebral column.

    PubMed

    Ramos, Renato M; da Costa, Ronaldo C; Oliveira, Andre L A; Kodigudla, Manoj K; Goel, Vijay K

    2015-08-06

    Previous studies in humans have reported that the dimensions of the intervertebral foramina change significantly with movement of the spine. Cervical spondylomyelopathy (CSM) in dogs is characterized by dynamic and static compressions of the neural components, leading to variable degrees of neurologic deficits and neck pain. Studies suggest that intervertebral foraminal stenosis has implications in the pathogenesis of CSM. The dimensions of the cervical intervertebral foramina may significantly change during neck movements. This could have implication in the pathogenesis of CSM and other diseases associated with radiculopathy such as intervertebral disc disease. The purpose of this study was to quantify the morphological changes in the intervertebral foramina of dogs during flexion, extension, traction, and compression of the canine cervical vertebral column. All vertebral columns were examined with magnetic resonance imaging prior to biomechanic testing. Eight normal vertebral columns were placed in Group 1 and eight vertebral columns with intervertebral disc degeneration or/and protrusion were assigned to Group 2. Molds of the left and right intervertebral foramina from C4-5, C5-6 and C6-7 were taken during all positions and loading modes. Molds were frozen and vertical (height) and horizontal (width) dimensions of the foramina were measured. Comparisons were made between neutral to flexion and extension, flexion to extension, and traction to compression in neutral position. Extension decreased all the foraminal dimensions significantly, whereas flexion increased all the foraminal dimensions significantly. Compression decreased all the foraminal dimensions significantly, and traction increased the foraminal height, but did not significantly change the foraminal width. No differences in measurements were seen between groups. Our results show movement-related changes in the dimensions of the intervertebral foramina, with significant foraminal narrowing in extension

  9. A case of severe and rigid congenital thoracolumbar lordoscoliosis with diastematomyelia presenting with type 2 respiratory failure: managed by staged correction with controlled axial traction.

    PubMed

    Kanagaraju, Vijayanth; Chhabra, H S; Srivastava, Abhishek; Mahajan, Rajat; Kaul, Rahul; Bhatia, Pallav; Tandon, Vikas; Nanda, Ankur; Sangondimath, Gururaj; Patel, Nishit

    2016-10-01

    Congenital lordoscoliosis is an uncommon pathology and its management poses formidable challenge especially in the presence of type 2 respiratory failure and intraspinal anomalies. In such patients standard management protocols are not applicable and may require multistage procedure to minimize risk and optimize results. A 15-year-old girl presented in our hospital emergency services with severe breathing difficulty. She had a severe and rapidly progressing deformity in her back, noted since 6 years of age, associated with severe respiratory distress requiring oxygen and BiPAP support. She was diagnosed to have a severe and rigid congenital right thoracolumbar lordoscoliosis (coronal Cobb's angle: 105° and thoracic lordosis -10°) with type 1 split cord malformation with bony septum extending from T11 to L3. This leads to presentation of restrictive lung disease with type 2 respiratory failure. As her lung condition did not allow for any major procedure, we did a staged procedure rather than executing in a single stage. Controlled axial traction by halogravity was applied initially followed by halo-femoral traction. Four weeks later, this was replaced by halo-pelvic distraction device after a posterior release procedure with asymmetric pedicle substraction osteotomies at T7 and T10. Halo-pelvic distraction continued for 4 more weeks to optimize and correct the deformity. Subsequently definitive posterior stabilization and fusion was done. The detrimental effect of diastematomyelia resection in such cases is clearly evident from literature, so it was left unresected. A good scoliotic correction with improved respiratory function was achieved. Three years follow-up showed no loss of deformity correction, no evidence of pseudarthrosis and a good clinical outcome with reasonably balanced spine. The management of severe and rigid congenital lordoscoliotic deformities with intraspinal anomalies is challenging. Progressive reduction in respiratory volume in untreated

  10. Adaptive backstepping control of train systems with traction/braking dynamics and uncertain resistive forces

    NASA Astrophysics Data System (ADS)

    Song, Qi; Song, Y. D.; Cai, Wenchuan

    2011-09-01

    Although backstepping control design approach has been widely utilised in many practical systems, little effort has been made in applying this useful method to train systems. The main purpose of this paper is to apply this popular control design technique to speed and position tracking control of high-speed trains. By integrating adaptive control with backstepping control, we develop a control scheme that is able to address not only the traction and braking dynamics ignored in most existing methods, but also the uncertain friction and aerodynamic drag forces arisen from uncertain resistance coefficients. As such, the resultant control algorithms are able to achieve high precision train position and speed tracking under varying operation railway conditions, as validated by theoretical analysis and numerical simulations.

  11. The Outcomes of Pars Plana Vitrectomy without Tamponade for Tractional Retinal Detachment Secondary to Diabetic Retinopathy

    PubMed Central

    Qamar, Rao Muhammad Rashad; Saleem, Muhammad Imran; Saleem, Muhammad Farhan

    2013-01-01

    Background: The objective of this research was to evaluate the outcomes of pars plana vitrectomy (PPV) without the use of an ocular tamponade in patients with tractional retinal detachment (TRD) secondary to proliferative diabetic retinopathy (PDR) presenting to Bahawal Victoria Hospital, Bahawalpur, Pakistan. Methods: This was an interventional study conducted at the Department of Ophthalmology, Bahawal Victoria (B.V.) Hospital, Bahawalpur, Pakistan, from July 2011 to July 2012. A total of 75 patients (84 eyes) with TRD secondary to PDR were treated by PPV without using an ocular tamponade. All patients included in the study had a TRD secondary to PDR but did not have or develop retinal breaks before or during the study period. The surgical procedure included a PPV combined with the removal of the tractional retinal membranes and the application of endolaser photocoagulation to the retina. The mean follow-up period was 12 months. Results: The study included 75 patients (84 eyes). Among these, 40 patients were females and 35 males. Successful retinal reattachment was observed in 78 of the operated eyes (92.8%). In these patients, the retina remained attached until the end of the 12 month follow-up period. Improvement in best corrected visual acuity (BCVA) was seen in 63 eyes (75%). The visual acuity remained unchanged in nine eyes (10.7%). Mean improvement in BCVA was 2.00 ± 1.24 at baseline to 1.24 ± 1.22 (P = 0.010) at the end of the follow-up period. Conclusion: In the absence of retinal breaks, a TRD secondary to PDR can be successfully treated and improved by PPV without the use of an ocular tamponade. PMID:23966826

  12. Closed reduction of displaced or dislocated mandibular condyle fractures in children using threaded Kirschner wire and external rubber traction.

    PubMed

    Kim, J H; Nam, D H

    2015-10-01

    Most surgeons agree that closed treatment provides the best results for condylar fractures in children. Nevertheless, treatment of the paediatric mandibular condyle fracture that is severely displaced or dislocated is controversial. The purpose of this study was to investigate the long-term clinical and radiological outcomes following the treatment of displaced or dislocated condylar fractures in children using threaded Kirschner wire and external rubber traction. This procedure can strengthen the advantage of closed reduction and make up for the shortcomings of open reduction. From March 1, 2005 to December 25, 2011, 11 children aged between 4 and 12 years with displaced or dislocated mandibular condyle fractures were treated using threaded Kirschner wire and external rubber traction under portable C-arm fluoroscopy. All patients had unilateral displaced or dislocated condylar fractures. The follow-up period ranged from 24 to 42 months (mean 29.3 months). Normal occlusion and pain-free function of the temporomandibular joint, without deviation or limitation of jaw opening, was achieved in all patients. This closed reduction technique in displaced or dislocated condylar fractures in children offers a reliable solution in preventing the unfavourable sequelae of closed treatment and the open technique, such as altered morphology, functional disturbances, and facial nerve damage. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Development And Use Of Advanced Microfabricated Traction Force Sensing Substrates To Study The Effect of Nanosilver On Human Macrophages

    NASA Astrophysics Data System (ADS)

    Stark, Daniel Thomas

    While nanoparticles are a natural byproduct of combustion and a number of natural processes, engineered nanoparticles have only recently entered the consumer market. This motivates the development of methods for studying their effects on human cells, thereby indicating how larger models such as animals and humans might react to them. This research develops a method to mechanically characterize cellular traction forces as a measure of exposure to nanoparticles. To do this, 1microm micropillar molds were fabricated in silicon wafers using smooth sidewall reactive ion plasma etching technologies. Polydimethylsiloxane (PDMS), was cured inside the silicon molds, subsequently treated for cell culture and used to measure cellular traction forces over time in live cell time-lapse experiments. For the first time, transmitted light was used to visualize the PDMS micropillars; a force resolution of 5.6 +/-2.1nN was achieved across all experiments using a standard Olympus IX81 confocal microscope affixed with a 60x NA2.1 objective. To initiate cellular movement, monocyte chemoattractant protein (MCP-1) was conjugated to 1microm latex beads. The effects of 40nm silver nanoparticle exposures were quantified using the micropillar array. Changes in cellular behavior between the control group and cells exposed to nanosilver were not significant, although a comparison between the 5microg/ml and 10microg/ml nanosilver concentrations yielded strong significance using a 2 sided Students t test.

  14. [Pharmaological vitreolysis with ocriplasmin as a treatment option for symptomatic focal vitreomacular traction with or without macular holes (≤400 μm) compared to tranconjunctival vitrectomy].

    PubMed

    Maier, M; Abraham, S; Frank, C; Lohmann, C P; Feucht, N

    2017-02-01

    To evaluate the resolution rate in patients with symptomatic vitreomacular traction (VMT) ≤ 1500 μm with or without macular holes ≤ 400 μm after therapy with intravitreal ocriplasmin (Jetrea®) injections in a clinical setting in comparison to transconjunctival vitrectomy. We examined 21 eyes of 21 consecutive patients with vitreomacular traction with or without macular holes who underwent intravitreal injection of 0.1 ml ocriplasmin and we retrospectively reviewed 18 eyes of 18 patients with VMT with or without FTMH who underwent 23-gauge vitrectomy. Vitreomacular traction resolved in 15 of 21 eyes treated with ocriplasmin after 6 month (71 %) compared to 100 % of eyes treated by vitrectomy. Of the 5 eyes that initially presented FTMH with VMT in the ocriplasmin group, 2 were closed 1 month after ocriplasmin treatment. The remaining 3 had vitrectomy and closed thereafter. Best corrected visual acuity was 0.38 ± 0.23 LogMAR at baseline, improving to 0.34 ± 0.24 LogMAR at 6 months after ocriplasmin treatment. Best corrected visual acuity in the vitrectomy group improved from 0.55 ± 0.29 LogMAR before operation to 0.53 ± 0.51 LogMAR 6 months postoperatively. Foveal thickness was 355.95 ± 114.53 μm at baseline, reducing to 277.77 ± 40.26 μm at 6 months after ocriplasmin treatment. Foveal thickness of eyes that underwent vitrectomy was 494.61 ± 126.02 μm at baseline, decreasing to 330.2 ± 88.85 μm 6 months postoperatively. When traction is ≤ 1500 μm, enzymatic vitreolysis with ocriplasmin is a therapeutic option. In the presence of VMT >1500 μm or ERM, surgical treatment with vitrectomy is associated with better outcomes. In small macular holes with VMT and in the absence of ERM, enzymatic vitreolysis with ocriplasmin is an option. In cases of holes >400 μm, or in the absence of evident VMT, or in the presence of ERM, vitrectomy is the first choice.

  15. The emergence of extracellular matrix mechanics and cell traction forces as important regulators of cellular self-organization.

    PubMed

    Checa, Sara; Rausch, Manuel K; Petersen, Ansgar; Kuhl, Ellen; Duda, Georg N

    2015-01-01

    Physical cues play a fundamental role in a wide range of biological processes, such as embryogenesis, wound healing, tumour invasion and connective tissue morphogenesis. Although it is well known that during these processes, cells continuously interact with the local extracellular matrix (ECM) through cell traction forces, the role of these mechanical interactions on large scale cellular and matrix organization remains largely unknown. In this study, we use a simple theoretical model to investigate cellular and matrix organization as a result of mechanical feedback signals between cells and the surrounding ECM. The model includes bi-directional coupling through cellular traction forces to deform the ECM and through matrix deformation to trigger cellular migration. In addition, we incorporate the mechanical contribution of matrix fibres and their reorganization by the cells. We show that a group of contractile cells will self-polarize at a large scale, even in homogeneous environments. In addition, our simulations mimic the experimentally observed alignment of cells in the direction of maximum stiffness and the building up of tension as a consequence of cell and fibre reorganization. Moreover, we demonstrate that cellular organization is tightly linked to the mechanical feedback loop between cells and matrix. Cells with a preference for stiff environments have a tendency to form chains, while cells with a tendency for soft environments tend to form clusters. The model presented here illustrates the potential of simple physical cues and their impact on cellular self-organization. It can be used in applications where cell-matrix interactions play a key role, such as in the design of tissue engineering scaffolds and to gain a basic understanding of pattern formation in organogenesis or tissue regeneration.

  16. Conventional versus traction-assisted endoscopic submucosal dissection for gastric neoplasms: a multicenter, randomized controlled trial (with video).

    PubMed

    Yoshida, Masao; Takizawa, Kohei; Suzuki, Sho; Koike, Yoshiki; Nonaka, Satoru; Yamasaki, Yasushi; Minagawa, Takeyoshi; Sato, Chiko; Takeuchi, Chihiro; Watanabe, Ko; Kanzaki, Hiromitsu; Morimoto, Hiroyuki; Yano, Takafumi; Sudo, Kosuke; Mori, Keita; Gotoda, Takuji; Ono, Hiroyuki

    2018-05-01

    The aim of this study was to clarify whether dental floss clip (DFC) traction improves the technical outcomes of endoscopic submucosal dissection (ESD). A superiority, randomized control trial was conducted at 14 institutions across Japan. Patients with single gastric neoplasm meeting the indications of the Japanese guidelines for gastric treatment were enrolled and assigned to receive conventional ESD or DFC traction-assisted ESD (DFC-ESD). Randomization was performed according to a computer-generated random sequence with stratification by institution, tumor location, tumor size, and operator experience. The primary endpoint was ESD procedure time, defined as the time from the start of the submucosal injection to the end of the tumor removal procedure. Between July 2015 and September 2016, 640 patients underwent randomization. Of these, 316 patients who underwent conventional ESD and 319 patients who underwent DFC-ESD were included in our analysis. The mean ESD procedure time was 60.7 and 58.1 minutes for conventional ESD and DFC-ESD, respectively (P = .45). Perforation was less frequent in the DFC-ESD group (2.2% vs .3%, P = .04). For lesions located in the greater curvature of the upper or middle stomach, the mean procedure time was significantly shorter in the DFC-ESD group (104.1 vs 57.2 minutes, P = .01). Our findings suggest that DFC-ESD does not result in shorter procedure time in the overall patient population, but it can reduce the risk of perforation. When selectively applied to lesions located in the greater curvature of the upper or middle stomach, DFC-ESD provides a remarkable reduction in procedure time. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  17. Mathematical Description of THE Traction Characteristics of the Driving Devices at Spatial Stiffness Compensators of the Vibration Isolation Installations

    NASA Astrophysics Data System (ADS)

    Gurova, E. G.

    2016-08-01

    During the researches the mathematical description of the traction characteristics of the stiffness compensators of the vibration isolation devices, relatively of the each axis, has been done. Representation of the compensators properties considers the variable load, thereby provide the wide enough spectrum of the action of the suggested vibration isolators. The derived expressions are valid for all three axes of space at the different stiffnesses, i.e. basic basic and two compensating. The research was supported by the scholarships of Russian Federation President for young scientists №184 from 10th of March 2015.

  18. A Traction Control Strategy with an Efficiency Model in a Distributed Driving Electric Vehicle

    PubMed Central

    Lin, Cheng

    2014-01-01

    Both active safety and fuel economy are important issues for vehicles. This paper focuses on a traction control strategy with an efficiency model in a distributed driving electric vehicle. In emergency situation, a sliding mode control algorithm was employed to achieve antislip control through keeping the wheels' slip ratios below 20%. For general longitudinal driving cases, an efficiency model aiming at improving the fuel economy was built through an offline optimization stream within the two-dimensional design space composed of the acceleration pedal signal and the vehicle speed. The sliding mode control strategy for the joint roads and the efficiency model for the typical drive cycles were simulated. Simulation results show that the proposed driving control approach has the potential to apply to different road surfaces. It keeps the wheels' slip ratios within the stable zone and improves the fuel economy on the premise of tracking the driver's intention. PMID:25197697

  19. A traction control strategy with an efficiency model in a distributed driving electric vehicle.

    PubMed

    Lin, Cheng; Cheng, Xingqun

    2014-01-01

    Both active safety and fuel economy are important issues for vehicles. This paper focuses on a traction control strategy with an efficiency model in a distributed driving electric vehicle. In emergency situation, a sliding mode control algorithm was employed to achieve antislip control through keeping the wheels' slip ratios below 20%. For general longitudinal driving cases, an efficiency model aiming at improving the fuel economy was built through an offline optimization stream within the two-dimensional design space composed of the acceleration pedal signal and the vehicle speed. The sliding mode control strategy for the joint roads and the efficiency model for the typical drive cycles were simulated. Simulation results show that the proposed driving control approach has the potential to apply to different road surfaces. It keeps the wheels' slip ratios within the stable zone and improves the fuel economy on the premise of tracking the driver's intention.

  20. Rolling-element fatigue life with traction fluids and automatic transmission fluid in a high-speed rolling-contact rig

    NASA Technical Reports Server (NTRS)

    Parker, R. J.; Nahm, A. H.; Loewenthal, S. H.

    1982-01-01

    Rolling-element fatigue tests were run in standard and high-speed rolling-contact rigs at bar speeds from 5000 to 50,000 rpm to determine the effects of speed and lubricant film parameter on rolling-element fatigue life. AISI 52100 test bars were tested at a maximum Hertz stress of 4.83 GPa (700,000 psi) with three traction fluids and an automatic transmission fluid. Rolling-element fatigue life increased with speed, with the greatest increases occurring from 10,000 to 50,000 rpm. The life data tended to follow published life-versus-lubricant-film-parameter data up to a film parameter of approximately 3.

  1. Characterization of Intracellular Streaming and Traction Forces in Migrating Physarum Plasmodia

    NASA Astrophysics Data System (ADS)

    Zhang, Shun; Del Alamo, Juan C.; Guy, Robert D.; Lasheras, Juan C.

    2012-11-01

    Physarum plasmodium is a model organism for cell migration that exhibits fast intracellular streaming. Motile amoeboid physarum plasmodia were obtained from dish cultures of Physarum Polycephalum, a slime mold that inhabits shady cool moist areas in the wild, such as decaying vegetable material. The migrating amoebae were obtained by cutting successively smaller pieces from the growing tips of the cultured parent mold, and their size ranged 0.2 to 0.5 mm. Single amoebae were seeded and let adhere on flexible polyacrilamide gels that were functionalized with collagen, contained 0.2-micron fluorescent beads, and were embedded in an aqueous medium. Soon after adhering to the gel, the amoeabe began crawling at about 1mm/hr. Joint time-lapse sequences of intracellular streaming and gel deformation were acquired respectively in the bright and fluorescent fields of a confocal microscope at 20X magnification. These images were analyzed using particle-tracking algorithms, and the traction stresses applied by the amoebae on the surface were computed by solving the elastostatic equation for the gel using the measured bead displacements as boundary conditions. These measurements provide, for the first time, a joint characterization of intracellular mass transport and the forces driving this transport in motile amoeboid cells.

  2. [Clinical observation on external humeral epicondylitis treated with back-rotation traction].

    PubMed

    Fu, Rui-yang; Wang, Ya-ling; Gu, Zhong-zhong; Wang, Bao-hu; Zhu, Qi; Li, Ye; Wang, En-ping

    2009-02-01

    To evaluate the clinical effect of manipulation on external humeral epicondylitis, and to explore the functional mechanism and ideal treatment. Eighty-six patients who had been treated with acupuncture, obturation and needle-knife were divided into routine group and treatment group randomly. In routine group, there were 42 cases (male 13, female 29, means 40.8 years); and in treatment group there were 44 cases (male 16, female 28, means 41.2 years). There's no further treatment for the routine group after the therapy above, while the treatment group was added with back-rotation traction manipulation. Taking Verhaar therapy effect appraisal system of tennis-ball elbow to evaluate elbow function. After 7 days of therapy, the results were excellent in 13 cases, good in 16, fair in 4, poor in 9 in the routine group; and excellent in 38, good in 4 and fair in 2 in treatment group; and the effect in the treatment group were better than that of the routine group (P < 0.010). Half a year later, in the routine group 38 cases recurrenced and in the treatment group 10 cases recurrenced. Making manipulation after routine acupuncture, local obturation and needle-knife has active meaning to remove trauma inflammation, prevent re-conglutination, promote recovery and prevent recurrence.

  3. Intergranular fracture in UO2: derivation of traction-separation law from atomistic simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yongfeng Zhang; Paul C Millett; Michael R Tonks

    2013-10-01

    In this study, the intergranular fracture behavior of UO2 was studied by molecular dynamics simulations using the Basak potential. In addition, the constitutive traction-separation law was derived from atomistic data using the cohesive-zone model. In the simulations a bicrystal model with the (100) symmetric tilt E5 grain boundaries was utilized. Uniaxial tension along the grain boundary normal was applied to simulate Mode-I fracture. The fracture was observed to propagate along the grain boundary by micro-pore nucleation and coalescence, giving an overall intergranular fracture behavior. Phase transformations from the Fluorite to the Rutile and Scrutinyite phases were identified at the propagatingmore » crack tips. These new phases are metastable and they transformed back to the Fluorite phase at the wake of crack tips as the local stress concentration was relieved by complete cracking. Such transient behavior observed at atomistic scale was found to substantially increase the energy release rate for fracture. Insertion of Xe gas into the initial notch showed minor effect on the overall fracture behavior.« less

  4. Multiple incipient sensor faults diagnosis with application to high-speed railway traction devices.

    PubMed

    Wu, Yunkai; Jiang, Bin; Lu, Ningyun; Yang, Hao; Zhou, Yang

    2017-03-01

    This paper deals with the problem of incipient fault diagnosis for a class of Lipschitz nonlinear systems with sensor biases and explores further results of total measurable fault information residual (ToMFIR). Firstly, state and output transformations are introduced to transform the original system into two subsystems. The first subsystem is subject to system disturbances and free from sensor faults, while the second subsystem contains sensor faults but without any system disturbances. Sensor faults in the second subsystem are then formed as actuator faults by using a pseudo-actuator based approach. Since the effects of system disturbances on the residual are completely decoupled, multiple incipient sensor faults can be detected by constructing ToMFIR, and the fault detectability condition is then derived for discriminating the detectable incipient sensor faults. Further, a sliding-mode observers (SMOs) based fault isolation scheme is designed to guarantee accurate isolation of multiple sensor faults. Finally, simulation results conducted on a CRH2 high-speed railway traction device are given to demonstrate the effectiveness of the proposed approach. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Antigravity ESD - double-balloon-assisted underwater with traction hybrid technique.

    PubMed

    Sharma, Sam K; Hiratsuka, Takahiro; Hara, Hisashi; Milsom, Jeffrey W

    2018-06-01

     Complex colorectal polyps or those positioned in difficult anatomic locations are an endoscopic therapeutic challenge. Underwater endoscopic submucosal dissection (UESD) is a potential technical solution to facilitate efficient polyp removal. In addition, endoscopic tissue retraction has been confined to limited methods of varying efficacy and complexity. The aim of this study was to evaluate the efficiency of a unique UESD technique for removing complex polyps using double-balloon-assisted retraction (R).  Using fresh ex-vivo porcine rectum, 4-cm polyps were created using electrosurgery and positioned at "6 o'clock" within an established ESD model. Six resections were performed in each group. Underwater techniques were facilitated using a novel double-balloon platform (Dilumen, Lumendi, Westport, Connecticut, United States).  UESD-R had a significantly shorter total procedural time than cap-assisted ESD and UESD alone (24 vs. 58 vs. 56 mins). UESD-R produced a dissection time on average of 5 minutes, attributed to the retraction provided. There was also a subjective significant reduction in electrosurgical smoke with the underwater techniques contributing to improved visualization.  Here we report the first ex-vivo experience of a unique double-balloon endoscopic platform optimized for UESD with tissue traction capability. UESD-R removed complex lesions in significantly shorter time than conventional means. The combined benefits of UESD and retraction appeared to be additive when tackling complex polyps and should be studied further.

  6. New model of inverting substation for DC traction with regenerative braking system

    NASA Astrophysics Data System (ADS)

    Omar, Abdul Malek Saidina; Samat, Ahmad Asri Abd; Isa, Siti Sarah Mat; Shamsuddin, Sarah Addyani; Jamaludin, Nur Fadhilah; Khyasudeen, Muhammad Farris

    2017-08-01

    This paper presents a power electronic devices application focus on modeling, analysis, and control of switching power converter in the inverting DC substation with regenerative braking system which is used to recycle the surplus regenerative power by feed it back to the main AC grid. The main objective of this research is to improve the switching power electronic converter of the railway inverting substation and optimize the maximum kinetic energy recovery together with minimum power losses from the railway braking system. Assess performance including efficiency and robustness will be evaluated in order to get the best solution for the design configuration. Research methodology included mathematical calculation, simulation, and detail analysis on modeling of switching power converter on inverting substation. The design stage separates to four main areas include rectification mode, regenerative mode, control inverter mode and filtering mode. The simulation result has shown that the regenerative inverter has a capability to accept a maximum recovery power on the regeneration mode. Total energy recovery has increase and power losses have decreases because inverter abilities to transfer the surplus energy back to the main AC supply. An Inverter controller with PWM Generator and PI Voltage Regulator has been designed to control voltage magnitude and frequency of the DC traction system.

  7. Effect of moisture on the traction-separation behavior of cellulose nanocrystal interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinko, Robert; Keten, Sinan, E-mail: s-keten@northwestern.edu; Department of Civil and Environmental Engineering, Northwestern University, 2145 Sheridan Road, Room A136, Evanston, Illinois 60208

    2014-12-15

    Interfaces and stress transfer between cellulose nanocrystals (CNCs) dictate the mechanical properties of hierarchical cellulose materials such as neat films and nanocomposites. An interesting question that remains is how the behavior of these interfaces changes due to environmental stimuli, most notably moisture. We present analyses on the traction-separation behavior between Iβ CNC elementary fibrils, providing insight into how the presence of a single atomic layer of water at these interfaces can drastically change the mechanical behavior. We find that molecular water at the interface between hydrophilic CNC surfaces has a negligible effect on the tensile separation adhesion energy. However, whenmore » water cannot hydrogen bond easily to the surface (i.e., hydrophobic surface), it tends to maintain hydrogen bonds with other water molecules across the interface and form a capillary bridge that serves to increase the energy required to separate the crystals. Under shear loading, water lowers the energy barriers to sliding by reducing the atomic friction and consequently the interlayer shear modulus between crystals. Our simulations indicate that these nanoscale interfaces and physical phenomena such as interfacial adhesion, interlayer shear properties, and stick-slip friction behavior can be drastically altered by the presence of water.« less

  8. Cell origami: self-folding of three-dimensional cell-laden microstructures driven by cell traction force.

    PubMed

    Kuribayashi-Shigetomi, Kaori; Onoe, Hiroaki; Takeuchi, Shoji

    2012-01-01

    This paper describes a method of generating three-dimensional (3D) cell-laden microstructures by applying the principle of origami folding technique and cell traction force (CTF). We harness the CTF as a biological driving force to fold the microstructures. Cells stretch and adhere across multiple microplates. Upon detaching the microplates from a substrate, CTF causes the plates to lift and fold according to a prescribed pattern. This self-folding technique using cells is highly biocompatible and does not involve special material requirements for the microplates and hinges to induce folding. We successfully produced various 3D cell-laden microstructures by just changing the geometry of the patterned 2D plates. We also achieved mass-production of the 3D cell-laden microstructures without causing damage to the cells. We believe that our methods will be useful for biotechnology applications that require analysis of cells in 3D configurations and for self-assembly of cell-based micro-medical devices.

  9. Intergranular fracture in UO{sub 2}: derivation of traction-separation law from atomistic simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yongfeng; Millett, P.C.; Tonks, M.R.

    2013-07-01

    In this study, the intergranular fracture behavior of UO{sub 2} was studied by molecular dynamics simulations using the Basak potential. In addition, the constitutive traction-separation law was derived from atomistic data using the cohesive-zone model. In the simulations a bicrystal model with the (100) symmetric tilt Σ5 grain boundaries was utilized. Uniaxial tension along the grain boundary normal was applied to simulate Mode-I fracture. The fracture was observed to propagate along the grain boundary by micro-pore nucleation and coalescence, giving an overall intergranular fracture behavior. Phase transformations from the Fluorite to the Rutile and Scrutinyite phases were identified at themore » propagating crack tips. These new phases are metastable and they transformed back to the Fluorite phase at the wake of crack tips as the local stress concentration was relieved by complete cracking. Such transient behavior observed at atomistic scale was found to substantially increase the energy release rate for fracture. Insertion of Xe gas into the initial notch showed minor effect on the overall fracture behavior. (authors)« less

  10. The multiaxial fatigue response of cylindrical geometry under proportional loading subject to fluctuating tractions

    NASA Astrophysics Data System (ADS)

    Martinez, Rudy D.

    A multiaxial fatigue model is proposed, as it would apply to cylindrical geometry in the form of industrial sized pressure vessels. The main focus of the multiaxial fatigue model will be based on using energy methods with the loading states confined to fluctuating tractions under proportional loading. The proposed fatigue model is an effort to support and enhance existing fatigue life predicting methods for pressure vessel design, beyond the ASME Boiler and Pressure Vessel codes, ASME Section VIII Division 2 and 3, which is currently used in industrial engineering practice for pressure vessel design. Both uniaxial and biaxial low alloy pearlittic-ferritic steel cylindrical cyclic test data are utilized to substantiate the proposed fatigue model. Approximate material hardening and softening aspects from applied load cycling states and the Bauschinger effect are accounted for by adjusting strain control generated hysteresis loops and the cyclic stress strain curve. The proposed fatigue energy model and the current ASME fatigue model are then compared with regards to the accuracy of predicting fatigue life cycle consistencies.

  11. Magnetic Resonance Imaging of Optic Nerve Traction During Adduction in Primary Open-Angle Glaucoma With Normal Intraocular Pressure

    PubMed Central

    Demer, Joseph L.; Clark, Robert A.; Suh, Soh Youn; Giaconi, JoAnn A.; Nouri-Mahdavi, Kouros; Law, Simon K.; Bonelli, Laura; Coleman, Anne L.; Caprioli, Joseph

    2017-01-01

    Purpose We used magnetic resonance imaging (MRI) to ascertain effects of optic nerve (ON) traction in adduction, a phenomenon proposed as neuropathic in primary open-angle glaucoma (POAG). Methods Seventeen patients with POAG and maximal IOP ≤ 20 mm Hg, and 31 controls underwent MRI in central gaze and 20° to 30° abduction and adduction. Optic nerve and sheath area centroids permitted computation of midorbital lengths versus minimum paths. Results Average mean deviation (±SEM) was −8.2 ± 1.2 dB in the 15 patients with POAG having interpretable perimetry. In central gaze, ON path length in POAG was significantly more redundant (104.5 ± 0.4% of geometric minimum) than in controls (102.9 ± 0.4%, P = 2.96 × 10−4). In both groups the ON became significantly straighter in adduction (28.6 ± 0.8° in POAG, 26.8 ± 1.1° in controls) than central gaze and abduction. In adduction, the ON in POAG straightened to 102.0% ± 0.2% of minimum path length versus 104.5% ± 0.4% in central gaze (P = 5.7 × 10−7), compared with controls who straightened to 101.6% ± 0.1% from 102.9% ± 0.3% in central gaze (P = 8.7 × 10−6); and globes retracted 0.73 ± 0.09 mm in POAG, but only 0.07 ± 0.08 mm in controls (P = 8.8 × 10−7). Both effects were confirmed in age-matched controls, and remained significant after correction for significant effects of age and axial globe length (P = 0.005). Conclusions Although tethering and elongation of ON and sheath are normal in adduction, adduction is associated with abnormally great globe retraction in POAG without elevated IOP. Traction in adduction may cause mechanical overloading of the ON head and peripapillary sclera, thus contributing to or resulting from the optic neuropathy of glaucoma independent of IOP. PMID:28829843

  12. Performance and economic analysis of a plug and play regenerative brake for improving energy efficiency for traction elevators

    NASA Astrophysics Data System (ADS)

    Jeraputra, Chuttchaval; Tiptipakorn, Supun

    2017-05-01

    This paper presents performance and economic analysis of a plug and play regenerative brake for improving energy efficiency for traction elevators. The proposed regenerative brake recycles the energy loss of a dynamic brake and feeds into the grid while an elevator inverter is operating in the braking mode. According to field measurement of energy consumption, it reveals that the efficiency can be improved as much as 18%. The prototype of a regenerative brake 12 kW, 400V, 3ϕ is developed and tested on an elevator simulator. It is shown that it can transfer energy out of a DC capacitor before the dynamic brake kicks in. Further, an economic analysis is provided to carry out the payback period and the present worth equivalent to confirm economic feasibility.

  13. A semi-implicit augmented IIM for Navier–Stokes equations with open, traction, or free boundary conditions

    PubMed Central

    Li, Zhilin; Xiao, Li; Cai, Qin; Zhao, Hongkai; Luo, Ray

    2016-01-01

    In this paper, a new Navier–Stokes solver based on a finite difference approximation is proposed to solve incompressible flows on irregular domains with open, traction, and free boundary conditions, which can be applied to simulations of fluid structure interaction, implicit solvent model for biomolecular applications and other free boundary or interface problems. For some problems of this type, the projection method and the augmented immersed interface method (IIM) do not work well or does not work at all. The proposed new Navier–Stokes solver is based on the local pressure boundary method, and a semi-implicit augmented IIM. A fast Poisson solver can be used in our algorithm which gives us the potential for developing fast overall solvers in the future. The time discretization is based on a second order multi-step method. Numerical tests with exact solutions are presented to validate the accuracy of the method. Application to fluid structure interaction between an incompressible fluid and a compressible gas bubble is also presented. PMID:27087702

  14. A semi-implicit augmented IIM for Navier-Stokes equations with open, traction, or free boundary conditions.

    PubMed

    Li, Zhilin; Xiao, Li; Cai, Qin; Zhao, Hongkai; Luo, Ray

    2015-08-15

    In this paper, a new Navier-Stokes solver based on a finite difference approximation is proposed to solve incompressible flows on irregular domains with open, traction, and free boundary conditions, which can be applied to simulations of fluid structure interaction, implicit solvent model for biomolecular applications and other free boundary or interface problems. For some problems of this type, the projection method and the augmented immersed interface method (IIM) do not work well or does not work at all. The proposed new Navier-Stokes solver is based on the local pressure boundary method, and a semi-implicit augmented IIM. A fast Poisson solver can be used in our algorithm which gives us the potential for developing fast overall solvers in the future. The time discretization is based on a second order multi-step method. Numerical tests with exact solutions are presented to validate the accuracy of the method. Application to fluid structure interaction between an incompressible fluid and a compressible gas bubble is also presented.

  15. [Retrospective analysis of effects of metacarpus and phalanx traction on correction of scar contracture of hand after burn on the palm side].

    PubMed

    Chunsheng, Hou; Qingye, Liu; Hongfei, Hao; Yuying, Dong; Feng, Wang; Jin, Lei

    2015-06-01

    To analyze the effects of metacarpus and phalanx traction on correction of scar contracture of hand after burn on the palm side retrospectively. A total of 32 patients with 39 affected hands with scar contracture on the palm side after burn were hospitalized from May 2010 to December 2014. Method of treatment: scar contracture was conservatively released followed by skin grafting, which was referred to as method A; Kirschner wire was inserted into the middle or distal phalanx of finger with contracture and the corresponding metacarpus in the shape of U for 2 to 7 weeks' traction, which was referred to as method B; traction frame was built based on the traction pile and anchor formed by Kirschner wire inserted through the second to the fifth metacarpus and distal phalanx of finger with contracture, and then the affected fingers were pulled into a straight position with rubber bands for 2 to 6 months, which was referred to as method C. Method A was used in patients who would be treated with thorough release of scar followed by skin grafting routinely. Method B was used in patients who would be treated with intramedullary Kirschner wire fixation after release of scar contracture and skin transplantation routinely. Method C was further used in patients when methods A and B failed to accomplish the expected result. Method C was used in the first place followed by method A in whom there might be vascular decompensation or exposure of tendon and bone after scar release, and those who failed to meet the expectation were treated with method C in addition. Patients who were unwilling to undergo surgery were treated with method C exclusively. During the course of treatment, the presence or absence of infection and slipping of Kirschner wire or its slitting through soft tissue were observed. The presence or absence of tendency of recurrence of scar contracture within 1 to 2 weeks after treatment was observed. The length of palmar skin measuring from the root of finger with

  16. Black patients sustain vision loss while White and South Asian patients gain vision following delamination or segmentation surgery for tractional complications associated with proliferative diabetic retinopathy.

    PubMed

    Mastropasqua, R; Luo, Y H-L; Cheah, Y S; Egan, C; Lewis, J J; da Cruz, L

    2017-10-01

    PurposeThis retrospective comparative case series aims to determine whether patient ethnicity (White versus South Asian versus Black) is related to the outcome of surgical treatment for traction complications of severe proliferative diabetic retinopathy (PDR).SettingMoorfields Eye Hospital London, UK.MethodsAll patients who underwent vitrectomy with, delamination and/or segmentation for PDR over a 5-year period (2009-2014) were reviewed retrospectively. Patients were divided into White, South Asian or Black groups, and their age, gender, HbA1C and type of diabetes were recorded. A total of 484 patients (253 White, 117 South Asian, 114 Black) were included. Twenty-one patients were excluded due to inadequate documentation.OutcomesLogMAR Visual acuity (converted from Snellen) (VA), was recorded pre-operatively and ~6 months post surgery (range 5-8 months). Surgical outcome was classified according to the type and duration of tamponade required post-operatively.ResultsPre-operative VA and HbA1C values were similar across all three ethnic groups (P=0.64 and 0.569, respectively). Change in VA (mean±SD) was 0.41±0.78, 0.14±0.76 and -0.26±0.57 in White, South Asian and Black patient groups respectively (P<0.001). Multiple regression analysis showed that post-op VA was significantly related to race and pre-op VA only (both P<0.001). The Black patient group were more likely to require silicone oil tamponade (P<0.001) and long-term retention of silicone oil (P<0.001) than the White and South Asian patient groups.ConclusionsThis study demonstrates that Black patients on average lose vision following delamination surgery for traction complications of PDR while White and South Asian patients gain vision. The same group is also at higher risk of retaining silicone more than 6 months after surgery. This difference remains even when corrected for glycaemic control. The higher risk of visual loss and long-term retention of silicone oil in black patients requires further

  17. Direct observation of CD4 T cell morphologies and their cross-sectional traction force derivation on quartz nanopillar substrates using focused ion beam technique

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Joo; Kim, Gil-Sung; Hyung, Jung-Hwan; Lee, Won-Yong; Hong, Chang-Hee; Lee, Sang-Kwon

    2013-07-01

    Direct observations of the primary mouse CD4 T cell morphologies, e.g., cell adhesion and cell spreading by culturing CD4 T cells in a short period of incubation (e.g., 20 min) on streptavidin-functionalized quartz nanopillar arrays (QNPA) using a high-content scanning electron microscopy method were reported. Furthermore, we first demonstrated cross-sectional cell traction force distribution of surface-bound CD4 T cells on QNPA substrates by culturing the cells on top of the QNPA and further analysis in deflection of underlying QNPA via focused ion beam-assisted technique.

  18. Usefulness of a traction method using dental floss and a hemoclip for gastric endoscopic submucosal dissection: a propensity score matching analysis (with videos).

    PubMed

    Suzuki, Sho; Gotoda, Takuji; Kobayashi, Yoshiyuki; Kono, Shin; Iwatsuka, Kunio; Yagi-Kuwata, Naoko; Kusano, Chika; Fukuzawa, Masakatsu; Moriyasu, Fuminori

    2016-02-01

    Although endoscopic submucosal dissection (ESD) is a significant advancement in therapeutic endoscopy, it is a complicated technique and requires considerable expertise. In this exploratory study, we evaluated the efficacy of a simple traction method that uses dental floss and a hemoclip (DFC) and was developed to overcome the technical difficulties of ESD. In total, 238 early gastric cancers treated by ESD between May 2012 and December 2014 at Tokyo Medical University were retrospectively reviewed. Lesions treated by conventional ESD (n = 185) and by ESD with DFC (ESD-DFC) (n = 53) were compared. Multivariable analyses and propensity score matching were used to compensate for the differences in age, sex, resected specimen size, lesion location, lesion position, presence of ulceration, and operator level. The procedure time, rate of en bloc and complete resection, and rates of adverse events were evaluated between the 2 groups. Propensity score matching analysis created 43 matched pairs. Adjusted comparisons between ESD-DFC and conventional ESD showed similar treatment outcomes (en bloc resection rate: 97.7% vs 100%, P = .315; complete resection rate: 90.7% vs 95.3%, P = .397; perforation during ESD rate: 2.3% vs 2.3%, P = 1.000; post-ESD bleeding rate: 4.7% vs 4.7%, P = 1.000) but a significantly shorter procedure time for ESD-DFC (82.2 ± 79.5 minutes vs 118.2 ± 71.6 minutes, P = .002). ESD-DFC facilitated rapid ESD with good visualization and traction while ensuring high curability and safety. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  19. A Novel Adjustment Method for Shearer Traction Speed through Integration of T-S Cloud Inference Network and Improved PSO

    PubMed Central

    Si, Lei; Wang, Zhongbin; Yang, Yinwei

    2014-01-01

    In order to efficiently and accurately adjust the shearer traction speed, a novel approach based on Takagi-Sugeno (T-S) cloud inference network (CIN) and improved particle swarm optimization (IPSO) is proposed. The T-S CIN is built through the combination of cloud model and T-S fuzzy neural network. Moreover, the IPSO algorithm employs parameter automation adjustment strategy and velocity resetting to significantly improve the performance of basic PSO algorithm in global search and fine-tuning of the solutions, and the flowchart of proposed approach is designed. Furthermore, some simulation examples are carried out and comparison results indicate that the proposed method is feasible, efficient, and is outperforming others. Finally, an industrial application example of coal mining face is demonstrated to specify the effect of proposed system. PMID:25506358

  20. Characterizing components of the Saw Palmetto Berry Extract (SPBE) on prostate cancer cell growth and traction.

    PubMed

    Scholtysek, Carina; Krukiewicz, Aleksandra A; Alonso, José-Luis; Sharma, Karan P; Sharma, Pal C; Goldmann, Wolfgang H

    2009-02-13

    Saw Palmetto Berry Extract (SPBE) is applied for prostate health and treatment of urinary tract infections, nonbacterial prostitis and Benign Prostatic Hyperplasia (BPH) in man. An assumption is that SPBE affects tumor cell progression and migration in breast and prostate tissue. In this work, DU-145 cells were used to demonstrate that SPBE and its sterol components, beta-sitosterol and stigmasterol, inhibit prostate cancer growth by increasing p53 protein expression and also inhibit carcinoma development by decreasing p21 and p27 protein expression. In the presence of cholesterol, these features are not only reversed but increased significantly. The results show for the first time the potential of SPBE, beta-sitosterol and stigmasterol as potential anti-tumor agents. Since the protein p53 is also regarded as nuclear matrix protein facilitating actin cytoskeletal binding, 2D tractions were measured. The cell adhesion strength in the presence of SPBE, beta-sitosterol and cholesterol and the observation was that the increase in p53 expression triggered an increase in the intracellular force generation. The results suggest a dual function of p53 in cells.

  1. Four-port bimanual 23-gauge vitrectomy for diabetic tractional retinal detachment.

    PubMed

    Wang, Zhao-Yang; Zhao, Ke-Ke; Li, Jia-Kai; Rossmiller, Brian; Zhao, Pei-Quan

    2016-06-01

    Four-port bimanual vitrectomy is a surgical technique that facilitates removal of epiretinal membranes in severe proliferative diabetic retinopathy (PDR). As the illumination is held by the assistant through the fourth scleral incision, fibrovascular membranes are removed by bimanual manipulation techniques. The objective of this study was to evaluate the safety and efficacy of four-port bimanual 23-gauge vitrectomy for patients with tractional retinal detachment (TRD) in severe PDR. Retrospective, comparative, consecutive, interventional case series. Sixty-six eyes of 58 consecutive patients who underwent primary vitrectomy for severe diabetic TRD. Thirty-six eyes of 31 cases that were treated with four-port 23-gauge vitrectomy were compared with 30 eyes of 27 cases that were treated with 23-gauge pars plana vitrectomy (PPV). Main outcome measures were best-corrected visual acuity (BCVA), retinal status, intraocular pressure, and incidence of intraoperative and postoperative complications with at least 6 months of follow-up. The primary and ultimate anatomic success rates (94.4% versus 93.3%, and 100% in both groups, respectively) and the mean BCVA changes did not differ significantly between groups. The whole surgical time and the membrane removal time were significantly (p < 0.001, respectively) shorter in the four-port 23-gauge group than in the 23-gauge group. There was no difference in the incidence of intraoperative and postoperative complications in both groups. Four-port bimanual 23-gauge vitrectomy offers comparable anatomic success and shortens the surgical time compared with conventional 23-gauge PPV in patients with TRD resulting from severe PDR. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  2. [Assessment of rehabilitation progress in patients with cervical radicular pain syndrome after application of high intensity laser therapy - HILT and Saunders traction device].

    PubMed

    Haładaj, Robert; Pingot, Julia; Pingot, Mariusz

    2015-07-01

    Osteoarthritis of the spine is a major global health problem, it is an epidemic of our times. It affects all parts of the spine, but the hardest to treat is its cervical region. The cervical spine is most mobile, delicate and sensitive to any load. It requires special care in conservative treatment. To date the selection of effective therapeutic approaches has been controversial. The aim of the study was to assess the progress of rehabilitation in patients with cervical radicular pain syndrome after using two different methods of treatment: HILT and spinal axial traction with the use of Saunders device. The randomized study included 150 patients (81 women and 69 men, aged 24-67 years, mean age 45.5) divided into two groups of 75 patients each with characteristic symptoms of radicular pain. The measurement of the range of cervical spine movement of the cervical spine, visual analog scale for pain - VAS and a NDI questionnaire (Neck Disability Index - Polish version) - an indicator of functional disorders - were used to evaluate the effectiveness of the two different therapies. The results obtained by Saunders method remained significantly higher than those obtained when HILT laser therapy was used for most of the examined parameters. A thorough analysis of the results showed greater analgesic efficacy, improved global mobility and reduced functional impairment in patients treated with Saunders method. Both therapeutic methods manifest analgesic effect and a positive impact on the improvement of range of cervical spine movement in patients with radicular pain in this spine region. HILT laser therapy and Saunders traction device reduce neck disability index in the treated patients. © 2015 MEDPRESS.

  3. Idiopathic pulmonary fibrosis may be a disease of recurrent, tractional injury to the periphery of the aging lung: a unifying hypothesis regarding etiology and pathogenesis.

    PubMed

    Leslie, Kevin O

    2012-06-01

    Idiopathic pulmonary fibrosis is a progressive, fatal lung disease occurring in older individuals. Despite 50 years of accrued data about the disease, little progress has been made in slowing functional loss or in decreasing patient mortality. To present a novel hypothesis on the etiology and pathogenesis of idiopathic pulmonary fibrosis. Published data are reviewed regarding the epidemiology, clinical presentation, natural history, radiologic findings, and pathologic findings in patients with idiopathic pulmonary fibrosis. Patients with idiopathic pulmonary fibrosis may be predisposed genetically to tractional injury to the peripheral lung. The result is recurrent damage to the epithelial-mesenchymal interface, preferentially at the outer edges of the basilar lung lobules where tractional stress is high during inspiration, compliance is relatively low, and there is a greater tendency for alveolar collapse at end-expiration. A distinctive "reticular network of injury" (the fibroblast focus) forms, attended by a prolonged phase of wound repair (tear and slow repair). Discrete areas of alveolar collapse are observed in scar at the periphery of the lung lobules. The cycle repeats over many years resulting in progressive fibrous remodeling and replacement of the alveoli in a lobule by bronchiolar cysts surrounded by scar (honeycomb lung). Abnormalities in surfactant function are proposed as a potential mechanism of initial lung damage. Age of onset may be a function of a required threshold of environmental exposures (eg, cigarette smoking) or other comorbid injury to the aging lung. Evidence supporting this hypothesis is presented and potential mechanisms are discussed. A potential role for contributing cofactors is presented.

  4. Posterior axilla sling traction for shoulder dystocia: case review and a new method of shoulder rotation with the sling.

    PubMed

    Cluver, Catherine Anne; Hofmeyr, G Justus

    2015-06-01

    The purpose of this study was to report on all cases in which posterior axilla sling traction (PAST) has been used to deliver cases of intractable shoulder dystocia and to describe a new method of shoulder rotation with the sling. A record of all published and known cases was collected that included information on preliminary obstetric techniques that were used and how the PAST technique was performed. Maternal outcomes that included maternal injury and length of hospital stay and fetal outcomes, which included birthweight, Apgar scores, nerve injuries, fractures, hospital stay, and outcome, were documented. We have recorded 19 cases where PAST has been used. In 5 cases, the babies had died in utero. Ten were assisted deliveries. PAST was successful in 18 cases. In one case, it was partially successful because it enabled delivery of the posterior shoulder with digital axillary traction. The most commonly used material was suction tubing. Once the posterior shoulder was delivered, the shoulder dystocia was resolved in all cases. Time from insertion to delivery was <3 minutes when recorded. The birthweights of the infants varied from 3200-4800 g. Posterior arm humerus fractures occurred in 3 cases. There was one case of a permanent Erb's palsy and 4 cases of transient Erb's palsies. None were of the posterior arm. During this review, we found that, when direct delivery of the posterior shoulder was difficult because of very severe impaction, the sling could be used to rotate the shoulders easily through 180 degrees assisted by counter pressure on the back of the anterior shoulder. This new method was used in 5 cases and may reduce fetal trauma further during difficult shoulder delivery. This review confirms that PAST can be a lifesaving technique when all another techniques for shoulder dystocia fail. Advantages are that it is easy to use (even by someone who has not seen it used previously), that the sling material is readily available, and that it is inserted

  5. Textures and traction: how tube-dwelling polychaetes get a leg up

    PubMed Central

    Merz, Rachel Ann

    2015-01-01

    By controlling the traction between its body and the tube wall, a tube-dwelling polychaete can move efficiently from one end of its tube to the other, brace its body during normal functions (e.g., ventilation and feeding), and anchor within its tube avoiding removal by predators. To examine the potential physical interaction between worms and the tubes they live in, scanning electron microscopy was used to reveal and quantify the morphology of worm bodies and the tubes they produce for species representing 13 families of tube-dwelling polychaetes. In the tubes of most species there were macroscopic or nearly macroscopic (∼10 μm–1 mm) bumps or ridges that protruded slightly into the lumen of the tube; these could provide purchase as a worm moves or anchors. At this scale (∼10 μm-1 mm), the surfaces of the chaetal heads that interact with the tube wall were typically small enough to fit within spaces between these bumps (created by the inward projection of exogenous materials incorporated into the tube wall) or ridges (made by secretions on the interior surface of the tube). At a finer scale (0.01–10 μm), there was a second overlap in size, usually between the dentition on the surfaces of chaetae that interact with the tube walls and the texture provided by the secreted strands or microscopic inclusions of the inner linings. These linings had a surprising diversity of micro-textures. The most common micro-texture was a “fabric” of secreted threads, but there were also orderly micro-ridges, wrinkles, and rugose surfaces provided by microorganisms incorporated into the inner tube lining. Understanding the fine structures of tubes in conjunction with the morphologies of the worms that build them gives insight into how tubes are constructed and how worms live within them. PMID:25834379

  6. Lateral and posterior pillar grade changes during the treatment of Perthes disease in older patients using skin traction and range of motion exercises.

    PubMed

    Sugimoto, Yoshihisa; Akazawa, Hirofumi; Mitani, Shigeru; Tanaka, Masato; Nakagomi, Tadashi; Asaumi, Koji; Ozaki, Toshifumi

    2006-03-01

    The lateral pillar (LP) grade changes detected during treatment periods have received a lot of attention recently. Lappin et al. reported LP collapses in 92 of 275 (33%) patients during the treatment, but did not provide information for comparing treatment methods and age of onset of the disease. The purpose of this study was to review radiological changes in LP grade in older patients with Perthes disease during 20 months of treatment with skin traction and ROM exercises. We have also reported any grade changes in the posterior pillar (PP) classification. Twenty-one patients with unilateral disease who were 9 years or older at the onset of symptoms had been followed until skeletal maturity. Out of 21 older patients with Perthes disease, our study had two (9.5%) who experienced LP collapse and two (9.5%) who experienced PP collapse during the first 20 months of treatment. The average time from onset to hospitalization in hips, initially classified as LP group C and PP group C, was significantly longer than in LP and PP groups A and B. The LP collapse in two hips and PP collapse in two hips occurred during months 4-8 of treatment. On the other hand, of the patients allowed to ambulate with the Pogo stick orthosis from months 8 to 12 and without a brace from months 10 to 15, none had a collapse of their LPs or PPs during these periods. Lappin et al. reported that 92 of 275 patients (33%) who were managed conservatively in several hospitals experienced LP collapse during their treatment periods. Our results suggest that older patients with this disease treated with skin traction and ROM exercises rarely suffer a LP collapse, as compared with the Lappin et al. report.

  7. Traction Characteristics of a 30 by 11.5-14.5, Type 8, Aircraft Tire on Dry, Wet and Flooded Surfaces

    NASA Technical Reports Server (NTRS)

    Yager, T. J.; Dreher, R. C.

    1976-01-01

    A limited test program was conducted to extend and supplement the braking and cornering data on a 30 x 11.5-14.5, type VIII, aircraft tire to refine the tire/runway friction model for use in the development of an aircraft ground performance simulation. Tire traction data were obtained on dry, wet and flooded runway surfaces at ground speeds ranging from 5 to 100 knots and at yaw angles extending up to 12 deg. These friction coefficients are presented as a function of slip characteristics, namely, the maximum and skidding drag coefficients and the maximum cornering coefficients are presented as a function of both ground speed and yaw angle to extend existing data on that tire size. Tire braking and cornering capabilities were shown to be affected by vehicle ground speed, wheel yaw attitude and the extent of surface wetness.

  8. The Conceptual Structure of IMS Learning Design Does Not Impede Its Use for Authoring

    ERIC Educational Resources Information Center

    Derntl, M.; Neumann, S.; Griffiths, D.; Oberhuemer, P.

    2012-01-01

    IMS Learning Design (LD) is the only available interoperability specification in the area of technology enhanced learning that allows the definition and orchestration of complex activity flows and resource environments in a multirole setting. IMS LD has been available since 2003, and yet it has not been widely adopted either by practitioners or by…

  9. Social Sensors (S2ensors): A Kind of Hardware-Software-Integrated Mediators for Social Manufacturing Systems Under Mass Individualization

    NASA Astrophysics Data System (ADS)

    Ding, Kai; Jiang, Ping-Yu

    2017-09-01

    Currently, little work has been devoted to the mediators and tools for multi-role production interactions in the mass individualization environment. This paper proposes a kind of hardware-software-integrated mediators called social sensors (S2ensors) to facilitate the production interactions among customers, manufacturers, and other stakeholders in the social manufacturing systems (SMS). The concept, classification, operational logics, and formalization of S2ensors are clarified. S2ensors collect subjective data from physical sensors and objective data from sensory input in mobile Apps, merge them into meaningful information for decision-making, and finally feed the decisions back for reaction and execution. Then, an S2ensors-Cloud platform is discussed to integrate different S2ensors to work for SMSs in an autonomous way. A demonstrative case is studied by developing a prototype system and the results show that S2ensors and S2ensors-Cloud platform can assist multi-role stakeholders interact and collaborate for the production tasks. It reveals the mediator-enabled mechanisms and methods for production interactions among stakeholders in SMS.

  10. Tissue architecture, cell traction, deformable scaffolds, and the forces that shape the embryo during morphogenesis.

    NASA Astrophysics Data System (ADS)

    Davidson, Lance

    2005-03-01

    Morphogenesis is the process of constucting form and shape. Morphogenesis during early development of the embryo involves orchestrated movements of cells and tissues. These morphogenetic movements establish the body plan and organs of the early embryo. The rates and trajectories of these movements depend on three physical features of the early embryo: 1) the forces generated by cells, 2) the mechanical properties of the tissues, and 3) the architecture of the tissues. These three mechanical features of the embryo are some of the earliest phenotypic features generated by the genome. We are taking an interdisciplinary approach combining biophysical, cell biological, and classical embryological techniques to understand the mechanics of morphogenesis. Using nanoNewton-sensitive force transducers we can apply forces and measure time dependent elastic modulii of tissue fragments 100 micrometers across. Using traction-force microscopy we can measure forces generated by cells on their environment. We use drugs and chimeric proteins to investigate the localization and function of molecular complexes responsible for force generation and the modulus. We use microsurgery to take-apart and construct novel tissues to investigate the role of geometry and architecture in the mechanics of morphogenesis. Together with simulation techniques these quantitative approaches will provide us with a practical nuts-and-bolts understanding of how the genome encodes the shapes and forms of life.

  11. Repair of Total Tractional Retinal Detachment in Norrie Disease: Report of Technique and Successful Surgical Outcome.

    PubMed

    Todorich, Bozho; Thanos, Aristomenis; Yonekawa, Yoshihiro; Capone, Antonio

    2017-03-01

    Norrie disease is a rare, but devastating cause of pediatric retinal detachment, universally portending a poor visual prognosis. This paper describes successful surgical management of an infant with total retinal detachment associated with Norrie disease mutation. The infant was a full-term white male who presented with bilateral total funnel retinal detachments (RDs). He underwent genetic testing, which demonstrated single-point mutation 133 G>A transition in exon 2 of the NDP gene. The retinal detachment was managed with translimbal iridectomy, lensectomy, capsulectomy, and vitrectomy. Careful dissection of the retrolental membranes resulted in opening of the funnel. Single-stage surgery in this child's eye achieved re-attachment of the posterior pole with progressive reabsorption of subretinal fluid and cholesterol without the need for external drainage. Fluorescein angiography, performed at 2 months postoperatively, demonstrated perfusion of major vascular arcades, but with significant abnormalities and aneurysmal changes of higher-order vessels, suggestive of retinal and vascular dysplasia. The child has maintained brisk light perception vision. Early surgical intervention with careful dissection of tractional tissues can potentially result in good anatomic outcomes in some patients with Norrie disease-associated retinal detachment. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:260-262.]. Copyright 2017, SLACK Incorporated.

  12. Sovereignty and Collaboration: Affordable Strategies in Times of Austerity

    DTIC Science & Technology

    2016-10-01

    provide precision-guided bombs and a land-support SOVEREIGNTY—ANALYSIS 26 vehicle were delivered for more than 20 percent below the expenditure ini...weapon Precision-guided bomb Support vehicle Panther command & control vehicle Successor Identification Friend or Foe (IFF) Joint combat aircraft...GLMRS) Multi-role armoured vehicle (MRAV) Next-generation light anti-armoured weapon Precision-guided bomb Support vehicle Panther command & control

  13. The ability of a sustained within-session finding of pain reduction during traction to dictate improved outcomes from a manual therapy approach on patients with osteoarthritis of the hip.

    PubMed

    Wright, Alexis A; Abbott, J Haxby; Baxter, Dave; Cook, Chad

    2010-09-01

    THE OBJECTIVES OF THIS STUDY WERE TO: (1) determine the association of a within-session finding after traction of the hip with self-report of well-being, pain, and self-report of function at 9 weeks; and (2) to determine if the interactions between the within-session finding and the outcome measure are different between groups of patients with hip OA who receive and who do not receive manual therapy. Data were retrospectively analysed in 70 subjects who were part of a randomized control trial. Correlation analyses of within-session findings from the initial visit after traction of a concordantly painful hip were compared to self-report measures for function, pain, and well-being at 9 weeks. A comparison of slope coefficients between manual therapy and non-manual therapy groups was performed to determine the interactive aspects of the within-session finding. Although the correlations for the manual therapy group were higher than for the supervised neglect group, none of the correlational analyses for both groups was strong or significant. Significant differences in the slope coefficients for well-being and pain were found, suggesting that the interactions between the within-session findings and the targeted outcomes were different in the manual therapy group versus supervised neglect group. These findings suggest that within-session findings during the initial evaluation are not strongly related to a positive outcome after manual therapy, although the interaction of the finding of a within-session change and the use of manual therapy is more compelling than the finding in a sample of patients who did not receive manual therapy.

  14. [Clinical observation on improvement of motion range of cervical spine of patients with cervical spondylotic radiculopathy treated with rotation-traction manipulation and neck pain particles and cervical neck pain rehabilitation exercises].

    PubMed

    Zhen, Peng-Chao; Zhu, Li-Guo; Gao, Jing-Hua; Yu, Jie; Feng, Min-Shan; Wei, Xu; Wang, Shang-Quan

    2010-10-01

    To observe the effects of two different therapies on patients whose cervical function were restricted due to cervical spondylotic radiculopathy. Form April 2008 to October 2009, 71 cases with cervical spondylotic radiculopathy were divided into group A (36 cases) and group B (35 cases). Among them, 22 cases were male and 49 cases were female, ranging in age form 45 to 65 years with an average of 52.27 years, course of disease was from 3 days to 5 years. The patients in group A were treated with rotation-traction manipulation, neck pain particles and cervical rehabilitation exercises; and the patients in group B were treated with cervical traction, Diclofenac sodium sustained release tablets and wearing neck collar. Theapeutic time was two weeks. The cervical anteflexion, extension, left and right lateral bending, left and right rotative activity were measured by helmet-style activities instrument before and after treatment (at the 1, 3, 5, 7, 9, 11, 13 days and 1 month after treatment respectively). There were no difference between two groups in cervical activity in all directions before treatment (P > 0.05). Compared with the beginning, cervical anteflexion and extension showed significant difference at the 5th day after treatment in group A (P < 0.01). In group B, cervical anteflexion showed significant difference at the 13th day after treatment (P < 0.05), but at the 1 month after treatment, the significant difference disappeared (P > 0.05); cervical extension showed significant difference at the 7th day after treatment compared with the beginning (P < 0.05). Compared with the beginning,left lateral bending showed significant difference at the 1st day after treatment in group A (P < 0.05) and at the 5th day after treatment in group B (P < 0.01). Both in group A or B, right lateral bending, left and right rotative activity showed significant difference at the same time after treatment, either the 3rd day (P < 0.05) or the 5th day (P < 0.05). Compared between

  15. Adsorption force of fibronectin controls transmission of cell traction force and subsequent stem cell fate.

    PubMed

    Lin, Manping; Mao, Shilong; Wang, Jinfeng; Xing, Juan; Wang, Yuanliang; Cai, Kaiyong; Luo, Yanfeng

    2018-04-01

    The transmission of cell traction force (CTF) to underlying biomaterials is essential for adhered cells to measure and respond to their mechanical microenvironment. Given that the protein layer adsorbed on materials lies between the cells and materials, we hypothesize that the interfacial strength of protein-material interfaces (i.e., the adsorption force of proteins, F ad ) should have an important role in regulating the transmission of CTF. To test this hypothesis, rat mesenchymal stem cells (rMSCs) were cultured on poly(dimethyl siloxane) (PDMS) substrates with different F ad of fibronectin (FN), and the transmission of CTF was observed by immunofluorescence staining of FN and deformation of PDMS. As revealed, FN on substrates with low F ad is more liable to be desorbed by CTF, which prevents the transmission of CTF to substrates. In contrast, high F ad facilitates the transmission of CTF from rMSCs to the FN layer and PDMS substrates so that rMSCs can perceive the mechanical properties of substrates. We further demonstrated that the divergent transmission of CTF on low and high F ad substrates regulates the lineage specifications of rMSCs. Our study confirms the important role of F ad in CTF transmission and provides a new perspective to gain insights into cell-material interactions and cell fates, which may help to guide the design of better biomaterials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Whole-body vibration in heavy equipment operators of a front-end loader: role of task exposure and tire configuration with and without traction chains.

    PubMed

    Blood, Ryan P; Rynell, Patrik W; Johnson, Peter W

    2012-12-01

    This study measured whole-body vibration (WBV) exposures in front-end loader operators, and evaluated the effects of traction chains and work tasks on their WBV exposures. WBV exposures were measured and compared across three different front-end loader tire configurations: (a) stock rubber tires, (b) rubber tires with ladder chains, and (c) rubber tires with basket chains. The operators completed three distinct standardized tasks: driving on a city street, simulated plowing, and a simulated scooping and dumping task. A portable data acquisition system collected tri-axial time weighted and raw WBV data per ISO 2631-1 and 2631-5 standards. In addition, Global Positioning System (GPS) data were collected in order to compare loader speeds across tire conditions and the standardized tasks. Relative to the stock rubber tires, both types of tire chains significantly increased WBV exposures with the ladder chains having substantially higher WBV exposures compared to basket chains. Additionally, there were task dependent differences in WBV exposures. During the driving task, the z-axis (up and down) was the predominant exposure; the plowing task had a more even distribution of exposure across all three axes; while during scooping and dumping task, the x-axis (fore and aft) had the highest WBV exposures. The GPS data indicated that there were significant speed differences across tasks but not between the basket and ladder chain conditions. Tires with ladder chains increased the front-end loader operators' exposure to WBV above the ISO 2631-1 recommended eight hour action limit increasing risk for adverse health effects. Although more expensive, basket chains are recommended over ladder chains since they substantially lowered the front-end loader operator's exposures and may ultimately reduce vibration related wear and tear on the vehicle. In order to reduce a heavy equipment vehicle (HEV) operator's chances for developing low back pain, this study provides information that

  17. Cervical Spine Mechanism for Reproduction of the Biomechanical Behaviours of the Human Neck during Rotation-Traction Manipulation

    PubMed Central

    Zhu, Liguo

    2017-01-01

    Rotation-traction (RT) manipulation is a commonly used physical therapy procedure in TCM (traditional Chinese medicine) for cervical spondylosis. This procedure temporarily separates the C3 and C4 cervical vertebrae from each other when a physician applies a jerky action while the neck is voluntarily turned by the patient to a specific position as instructed by the physician, where the cervical vertebrae are twisted and locked. However, a high rate of cervical injury occurs due to inexperienced physician interns who lack sufficient training. Therefore, we developed a cervical spine mechanism that imitates the dynamic behaviours of the human neck during RT manipulation. First, in vivo and in vitro experiments were performed to acquire the biomechanical feature curves of the human neck during RT manipulation. Second, a mass-spring-damper system with an electromagnetic clutch was designed to emulate the entire dynamic response of the human neck. In this system, a spring is designed as rectilinear and nonlinear to capture the viscoelasticity of soft tissues, and an electromagnetic clutch is used to simulate the sudden disengagement of the cervical vertebrae. Test results show that the mechanism can exhibit the desired behaviour when RT manipulation is applied in the same manner as on humans. PMID:29259395

  18. U.S. Navy - U.S. Air Force Relationships 1970-2010. Revision

    DTIC Science & Technology

    2011-06-01

    OK(1992) • Inherited Looking Glass National Command Authorities (NCA) airborne strategic command & control role from USAF (1998) • Multi-role E...begins JTF HOA begins OIF begins PSI begins Iraq ABOT attack Indian Ocean tsunami Hurricane Katrina Bali terror bombings Lebanon evacuation DPRK...II) ^*NA • Material • Rising overall defense budgets • Stability of service budget shares • Imposed ceilings on service budgets • Personal

  19. Device for lengthening of a musculotendinous unit by direct continuous traction in the sheep

    PubMed Central

    2012-01-01

    Background Retraction, atrophy and fatty infiltration are signs subsequent to chronic rotator cuff tendon tears. They are associated with an increased pennation angle and a shortening of the muscle fibers in series. These deleterious changes of the muscular architecture are not reversible with current repair techniques and are the main factors for failed rotator cuff tendon repair. Whereas fast stretching of the retracted musculotendinous unit results in proliferation of non-contractile fibrous tissue, slow stretching may lead to muscle regeneration in terms of sarcomerogenesis. To slowly stretch the retracted musculotendinous unit in a sheep model, two here described tensioning devices have been developed and mounted on the scapular spine of the sheep using an expandable threaded rod, which has been interposed between the retracted tendon end and the original insertion site at the humeral head. Traction is transmitted in line with the musculotendinous unit by sutures knotted on the expandable threaded rod. The threaded rod of the tensioner is driven within the body through a rotating axis, which enters the body on the opposite side. The tendon end, which was previously released (16 weeks prior) from its insertion site with a bone chip, was elongated with a velocity of 1 mm/day. Results After several steps of technical improvements, the tensioner proved to be capable of actively stretching the retracted and degenerated muscle back to the original length and to withstand the external forces acting on it. Conclusion This technical report describes the experimental technique for continuous elongation of the musculotendinous unit and reversion of the length of chronically shortened muscle. PMID:22551079

  20. Image charge multi-role and function detectors

    NASA Astrophysics Data System (ADS)

    Milnes, James; Lapington, Jon S.; Jagutzki, Ottmar; Howorth, Jon

    2009-06-01

    The image charge technique used with microchannel plate imaging tubes provides several operational and practical benefits by serving to isolate the electronic image readout from the detector. The simple dielectric interface between detector and readout provides vacuum isolation and no vacuum electrical feed-throughs are required. Since the readout is mechanically separate from the detector, an image tube of generic design can be simply optimised for various applications by attaching it to different readout devices and electronics. We present imaging performance results using a single image tube with a variety of readout devices suited to differing applications: (a) A four electrode charge division tetra wedge anode, optimised for best spatial resolution in photon counting mode. (b) A cross delay line anode, enabling higher count rate, and the possibility of discriminating near co-incident events, and an event timing resolution of better than 1 ns. (c) A multi-anode readout connected, either to a multi-channel oscilloscope for analogue measurements of fast optical pulses, or alternately, to a multi-channel time correlated single photon counting (TCSPC) card.

  1. Hanging Maneuver for Stomach Traction in Laparoscopic Distal Pancreatic Resections: An Original Technique Applied in 218 Patients.

    PubMed

    Dokmak, Safi; Aussilhou, Béatrice; Ftériche, Fadhel Samir; Belghiti, Jacques; Sauvanet, Alain

    2017-01-01

    Stomach traction done to expose the pancreas is still a problem in laparoscopic left pancreatic resections. We developed a simple hanging maneuver to retract the stomach rapidly and effectively. After dividing the gastrocolic ligament, the stomach was encircled with a tape, turned along its horizontal axis and pulled with an epigastric trocar, which was later removed. This technique was used in all patients who underwent laparoscopic left pancreatic resections including 165 distal pancreatectomies (DP), 35 central pancreatectomies (CP) and 18 enucleations (En). Demographics, surgical and postoperative outcome data were recorded. There were no mortalities. The mean operative time for DP, CP and En were 174, 191 and 104 min, respectively. The transfusion (0-4%) and conversion (0-3%) rates were low for all procedures. Morbidity was mainly represented by pancreatic fistula and grades (B + C) for DP, CP and En were observed in 26, 22 and 17%, respectively. No complication related to hanging of the stomach, like gastric perforation, was observed. Re-intervention and the mean hospital stay for DP, CP and En were observed in 5, 11 and 0% and were 16, 22 and 12, respectively. The readmission rate was low (0-9%). Hanging maneuver of the stomach is a simple procedure to rapidly, safely and effectively retract the stomach during left laparoscopic pancreatic resections. © 2016 S. Karger AG, Basel.

  2. EFFICACY OF THE STRETCH BAND ANKLE TRACTION TECHNIQUE IN THE TREATMENT OF PEDIATRIC PATIENTS WITH ACUTE ANKLE SPRAINS: A RANDOMIZED CONTROL TRIAL

    PubMed Central

    Iammarino, Kathryn; Marrie, James; Lowes, Linda P.

    2018-01-01

    Background Ankle injuries account for up to 40% of all sport related injuries. These injuries can result in weeks to months of missed sport or work. The PRICE (Protection, Rest, Ice, Compression, Elevation) treatment is standard care for most acute ankle sprains. Recently, early mobilization in adults has been shown to decrease time off from sport or work, and the likelihood of developing chronic instability. To date, no research has been performed assessing the effectiveness of early mobilization in pediatric patients (<18 years). Purpose: There were two objectives of this study: (1) to determine if early ankle joint mobilization using elastic band traction is effective and (2) assess the occurrence of adverse events with this technique in the pediatric population. Methods Patients with an acute ankle sprain of <7 days referred to physical therapy were randomly assigned to receive early mobilization or PRICE. Early mobilization was performed using a stretch band ankle traction technique. Both groups received a standardized rehabilitation program. Pain, edema, ankle strength using hand-held dynamometry, and Foot and Ankle Disability Index (FADI) were measured at both initial evaluation and at discharge. The number of days before return to sport and the number of treatment sessions were also variables of interest. Results Forty-one pediatric patients were recruited for participation (mean age 14.6 + 1.9 years). Both treatment groups had clinically significant improvements in pain, edema, strength, and FADI scores. No significant differences in outcomes were noted between treatment groups. Mean number of days for return to sport for the PRICE group was 26.33 + 7.14 and the early mobilization group was 26.63 + 14.82, the difference between groups was not significant (p = 0.607). The number of total visits for the PRICE group of 8.07 + 2.63 and the early mobilization groups of 8.5 + 1.57, was also not statistically significantly different (p = 0

  3. EFFICACY OF THE STRETCH BAND ANKLE TRACTION TECHNIQUE IN THE TREATMENT OF PEDIATRIC PATIENTS WITH ACUTE ANKLE SPRAINS: A RANDOMIZED CONTROL TRIAL.

    PubMed

    Iammarino, Kathryn; Marrie, James; Selhorst, Mitchell; Lowes, Linda P

    2018-02-01

    Ankle injuries account for up to 40% of all sport related injuries. These injuries can result in weeks to months of missed sport or work. The PRICE (Protection, Rest, Ice, Compression, Elevation) treatment is standard care for most acute ankle sprains. Recently, early mobilization in adults has been shown to decrease time off from sport or work, and the likelihood of developing chronic instability. To date, no research has been performed assessing the effectiveness of early mobilization in pediatric patients (<18 years). Purpose: There were two objectives of this study: (1) to determine if early ankle joint mobilization using elastic band traction is effective and (2) assess the occurrence of adverse events with this technique in the pediatric population. Patients with an acute ankle sprain of <7 days referred to physical therapy were randomly assigned to receive early mobilization or PRICE. Early mobilization was performed using a stretch band ankle traction technique. Both groups received a standardized rehabilitation program. Pain, edema, ankle strength using hand-held dynamometry, and Foot and Ankle Disability Index (FADI) were measured at both initial evaluation and at discharge. The number of days before return to sport and the number of treatment sessions were also variables of interest. Forty-one pediatric patients were recruited for participation (mean age 14.6 + 1.9 years). Both treatment groups had clinically significant improvements in pain, edema, strength, and FADI scores. No significant differences in outcomes were noted between treatment groups. Mean number of days for return to sport for the PRICE group was 26.33 + 7.14 and the early mobilization group was 26.63 + 14.82, the difference between groups was not significant ( p = 0.607). The number of total visits for the PRICE group of 8.07 + 2.63 and the early mobilization groups of 8.5 + 1.57, was also not statistically significantly different ( p = 0.762). There were no reported

  4. Puncture point-traction method: A novel method applied for right internal jugular vein catheterization

    PubMed Central

    WU, TIANLIANG; ZANG, HONGCHENG

    2016-01-01

    The ultrasound probe and advancement of the needle during real-time ultrasound-assisted guidance of catheterization of the right internal jugular vein (RIJV) tend to collapse the vein, which reduces the success rate of the procedure. We have developed a novel puncture point-traction method (PPTM) to facilitate RIJV cannulation. The present study examined whether this method facilitated the performance of RIJV catheterization in anesthetized patients. In this study, 120 patients were randomly assigned to a group in which PPTM was performed (PPTM group, n=60) or a group in which it was not performed (non-PPTM group, n=60). One patient was excluded because of internal carotid artery puncture and 119 patients remained for analysis. The cross-sectional area (CSA), anteroposterior diameter (AD) and transverse diameter (TD) of the RIJV at the cricoid cartilage level following the induction of anesthesia and during catheterization were measured, and the number with obvious loss of resistance (NOLR), the number with easy aspiration of blood into syringe (NEABS) during advancement of the needle, and the number of first-pass punctures (NFPP) during catheterization were determined. In the non-PPTM group, the CSA was smaller during catheterization compared with that following the induction of anesthesia (P<0.01). In the PPTM group compared with the non-PPTM group during catheterization, the CSA was larger (P<0.01) and the AD (P<0.01) and TD (P<0.05) were wider; NOLR (P<0.01), NEABS (P<0.01) and NFPP (P<0.01) increased significantly. The findings from this study confirmed that the PPTM facilitated catheterization of the RIJV and improved the success rate of RIJV catheterization in anesthetized patients in the supine position. PMID:27347054

  5. Intermittent Cervical Traction for Treating Neck Pain: A Meta-analysis of Randomized Controlled Trials.

    PubMed

    Yang, Jheng-Dao; Tam, Ka-Wai; Huang, Tsai-Wei; Huang, Shih-Wei; Liou, Tsan-Hon; Chen, Hung-Chou

    2017-07-01

    A meta-analysis. The aim of this study was to perform a comprehensive search of current literature and conduct a meta-analysis of randomized controlled trials (RCTs) to assess the neck pain relieving effect of intermittent cervical traction (ICT). Neck pain is a common and disabling problem with a high prevalence in general population. It causes a considerable burden on the health care system with a substantial expenditure. ICT is a common component of physical therapy for neck pain in the outpatient clinic. However, the evidence regarding the effectiveness of ICT for neck pain is insufficient. Data were obtained from the PubMed, Cochrane Library, Embase, and Scopus databases from the database inception date to July 02, 2016. RCTs reporting the effects of ICT on neck pain, including those comparing the effects of ICT with those of a placebo treatment, were included. Two reviewers independently reviewed the studies, conducted a risk of bias assessment, and extracted data. The data were pooled in a meta-analysis by using a random-effects model. The meta-analysis included seven RCTs. The results indicated that patients who received ICT for neck pain had significantly lower pain scores than those receiving placebos did immediately after treatment (standardized mean difference = -0.26, 95% confidence interval = -0.46 to -0.07). The pain scores during the follow-up period and the neck disability index scores immediately after treatment and during the follow-up period did not differ significantly. ICT may have a short-term neck pain-relieving effect. Some risks of bias were noted in the included studies, reducing the evidence level of this meta-analysis. Additional high-quality RCTs are required to clarify the long-term effects of ICT on neck pain. 1.

  6. Traction Drive Inverter Cooling with Submerged Liquid Jet Impingement on Microfinned Enhanced Surfaces (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waye, S.; Narumanchi, S.; Moreno, G.

    Jet impingement is one means to improve thermal management for power electronics in electric-drive traction vehicles. Jet impingement on microfin-enhanced surfaces further augments heat transfer and thermal performance. A channel flow heat exchanger from a commercial inverter was characterized as a baseline system for comparison with two new prototype designs using liquid jet impingement on plain and microfinned enhanced surfaces. The submerged jets can target areas with the highest heat flux to provide local cooling, such as areas under insulated-gate bipolar transistors and diode devices. Low power experiments, where four diodes were powered, dissipated 105 W of heat and weremore » used to validate computational fluid dynamics modeling of the baseline and prototype designs. Experiments and modeling used typical automotive flow rates using water-ethylene glycol as a coolant (50%-50% by volume). The computational fluid dynamics model was used to predict full inverter power heat dissipation. The channel flow and jet impingement configurations were tested at full inverter power of 40 to 100 kW (output power) on a dynamometer, translating to an approximate heat dissipation of 1 to 2 kW. With jet impingement, the cold plate material is not critical for the thermal pathway. A high-temperature plastic was used that could eventually be injection molded or formed, with the jets formed from a basic aluminum plate with orifices acting as nozzles. Long-term reliability of the jet nozzles and impingement on enhanced surfaces was examined. For jet impingement on microfinned surfaces, thermal performance increased 17%. Along with a weight reduction of approximately 3 kg, the specific power (kW/kg) increased by 36%, with an increase in power density (kW/L) of 12% compared with the baseline channel flow configuration.« less

  7. Quantitative analysis of the orthodontic and orthopedic effects of maxillary traction.

    PubMed

    Baumrind, S; Korn, E L; Isaacson, R J; West, E E; Molthen, R

    1983-11-01

    This article analyzes differences in displacement of ANS and of the upper first molar when different vectors of force are delivered to the maxilla in non-full-banded Phase I mixed-dentition treatment of Class II malocclusion. The sample is identical to that for which we have previously reported differences in change in several key measures of mandibular and facial shape. It includes a cervical-traction group, a high-pull-to-upper-molar group, a modified-activator group, and an untreated Class II control group. Using newly developed computer-conducted procedures, which are described, we have been able to partition the orthodontic and orthopedic components of upper molar displacement and also to isolate treatment effects from those attributable to spontaneous growth and development. In the region of ANS, small but statistically significant and clinically meaningful differences were noted between treatments. When the intercurrent effects of growth and development had been factored out (Table III), orthopedic distal displacement of ANS was significantly greater in the high-pull and cervical groups than in the activator group. Orthopedic downward displacement of ANS was seen to be significantly greater in the cervical group than in the high-pull and activator groups. In the region of the first molar cusp, mean distal displacement of the tooth as an orthopedic effect was found to be almost identical in the cervical and high-pull groups (although variability was greater in the cervical group), but the mean orthodontic effect was significantly greater in the high-pull group than in the cervical group. In the cervical group, where relatively light forces were used for relatively long treatment periods on average, more of the total distal displacement of the upper molar was of an orthopedic character than of an orthodontic character. Conversely, in the high-pull group, in which relatively heavier forces tended to be used for briefer treatment periods, most of the distal

  8. Investigation of fault modes in permanent magnet synchronous machines for traction applications

    NASA Astrophysics Data System (ADS)

    Choi, Gilsu

    Over the past few decades, electric motor drives have been more widely adopted to power the transportation sector to reduce our dependence on foreign oil and carbon emissions. Permanent magnet synchronous machines (PMSMs) are popular in many applications in the aerospace and automotive industries that require high power density and high efficiency. However, the presence of magnets that cannot be turned off in the event of a fault has always been an issue that hinders adoption of PMSMs in these demanding applications. This work investigates the design and analysis of PMSMs for automotive traction applications with particular emphasis on fault-mode operation caused by faults appearing at the terminals of the machine. New models and analytical techniques are introduced for evaluating the steady-state and dynamic response of PMSM drives to various fault conditions. Attention is focused on modeling the PMSM drive including nonlinear magnetic behavior under several different fault conditions, evaluating the risks of irreversible demagnetization caused by the large fault currents, as well as developing fault mitigation techniques in terms of both the fault currents and demagnetization risks. Of the major classes of machine terminal faults that can occur in PMSMs, short-circuit (SC) faults produce much more dangerous fault currents than open-circuit faults. The impact of different PMSM topologies and parameters on their responses to symmetrical and asymmetrical short-circuit (SSC & ASC) faults has been investigated. A detailed investigation on both the SSC and ASC faults is presented including both closed-form and numerical analysis. The demagnetization characteristics caused by high fault-mode stator currents (i.e., armature reaction) for different types of PMSMs are investigated. A thorough analysis and comparison of the relative demagnetization vulnerability for different types of PMSMs is presented. This analysis includes design guidelines and recommendations for

  9. Exploring the Feasibility of a Consolidated Joint Civil Augmentation Program (JCAP)

    DTIC Science & Technology

    2009-12-01

    operations. The primary focus of the program is on design and engineering, and infrastructure design and construction; however AFCAP also performs...Following is the primary research question: “Is it more cost effective for the Army, Navy, and Air Force to combine their individual CAPs into one JCAP...Force, Marines and U.S. Allies. “The program’s rationale and primary emphasis is joint-service development of a next-generation multi-role stirke

  10. Posturing Tactical ISR Beyond The Umbilical Cord

    DTIC Science & Technology

    2017-02-03

    intelligence sensors, it carries a lethal payload of ordinance for strike and or close air support missions. In fact, world media have discussed the MQ-9’s...awareness all their visual and signal intelligence sensors provide is a force multiplier that enhances mission success significantly. For example, when...on C-17 Photo Source http://www.aircav.com/dodphoto/dod98/mh60-002rs.jpg 407MRH multirole armed ISR ( intelligence , surveillance, reconnaissance

  11. An Analysis of Factors That Influence Logistics, Operational Availability, and Flight Hour Supply of the German Attack Helicopter Fleet

    DTIC Science & Technology

    2017-06-01

    maintenance times from the fleet are randomly resampled when running the model to enhance model realism. The use of a simulation model to represent the...helicopter regiment. 2. Attack Helicopter UH TIGER The EC665, or Airbus Helicopter TIGER, (Figure 3) is a four- bladed , twin- engine multi-role attack...migrated into the automated management system SAP Standard Product Family (SASPF), and the usage clock starts to run with the amount of the current

  12. Tactical Mobile Communications (Communications tactiques mobiles)

    DTIC Science & Technology

    1999-11-01

    13]. randomly at the network nodes. Each multicast group Our studies do, in fact, support this conjecture. consists of the source node plus at least...Capability investigate the MMR concept in some more detail. The study was contracted to a group which Multi-role denotes the capability to support a...through the HW- and SW-resources of the frontends can be incorporated in a task-dedicated GPU. Functions can be grouped into four categories: MMR

  13. Practical implementation of the concept of converted electric vehicle with advanced traction and dynamic performance and environmental safety indicators

    NASA Astrophysics Data System (ADS)

    Sidorov, K. M.; Yutt, V. E.; Grishchenko, A. G.; Golubchik, T. V.

    2018-02-01

    The objective of the work presented in this paper is to describe the implementation of the technical solutions have been developed, with regard to structure, composition, and characteristics, for an experimental prototype of an electric vehicle which has been converted from a conventional vehicle. The methodology of the study results is based on the practical implementation of the developed concept of the conversion of conventional vehicles into electric vehicles. The main components of electric propulsion system of the experimental prototype of electric vehicle are developed and manufactured on the basis of computational researches, taking into account the criteria and principles of conversion within the framework of presented work. The article describes a schematic and a design of power conversion and commutation electrical equipment, traction battery, electromechanical transmission. These results can serve as guidance material in the design and implementation of electric propulsion system (EPS) components of electric vehicles, facilitate the development of optimal technical solutions in the development and manufacture of vehicles, including those aimed at autonomy of operation and the use of perspective driver assistance systems. As part of this work, was suggested a rational structure for an electric vehicle experimental prototype, including technical performance characteristics of the components of EPS.

  14. Correction of Grade 2 Spondylolisthesis Following a Non-Surgical Structural Spinal Rehabilitation Protocol Using Lumbar Traction: A Case Study and Selective Review of Literature

    PubMed Central

    Fedorchuk, Curtis; Lightstone, Douglas F; McRae, Christi; Kaczor, Derek

    2017-01-01

    Objective Discuss the use of non-surgical spinal rehabilitation protocol in the case of a 69-year-old female with a grade 2 spondylolisthesis. A selective literature review and discussion are provided. Clinical Features A 69-year-old female presented with moderate low back pain (7/10 pain) and severe leg cramping (7/10 pain). Initial lateral lumbar x-ray revealed a grade 2 spondylolisthesis at L4-L5 measuring 13.3 mm. Interventions and Outcomes The patient completed 60 sessions of Mirror Image® spinal exercises, adjustments, and traction over 45 weeks. Post-treatment lateral lumbar x-ray showed a decrease in translation of L4-L5 from 13.3 mm to 2.4 mm, within normal limits. Conclusions This case provides the first documented evidence of a non-surgical or chiropractic treatment, specifically Chiropractic BioPhysics®, protocols of lumbar spondylolisthesis where spinal alignment was corrected. Additional research is needed to investigate the clinical implications and treatment methods. PMID:29299090

  15. The Debate is Over: Close Air Support in Korea and Vietnam

    DTIC Science & Technology

    2011-05-03

    F4U Corsair became Marine aviation’s plane of choice. Early models of the Corsair were formidable fighter aircraft best suited for the air...superiority role. By 1944, the Marine Corps made a deliberate effort to transform the Corsair from a fighter to a multi-role fighter- bomber. As such, the F4U...installation of a ten-channel radio facilitated better communications with ground forces. The upgraded Corsair was such an effective ground attack platform

  16. Middle ear polyps: results of traction avulsion after a lateral approach to the ear canal in 62 cats (2004-2014).

    PubMed

    Janssens, Sara Ds; Haagsman, Annika N; Ter Haar, Gert

    2017-08-01

    Objectives The objective of this study was to report the surgical outcome and complication rate of deep traction avulsion (TA) of feline aural inflammatory polyps after a lateral approach (LA) to the ear canal. Methods This was a retrospective analysis of data retrieved from an electronic database of 62 cats treated with TA after an LA (TALA) for removal of ear canal polyps. Long-term outcome was assessed via a telephone questionnaire survey with the owners. Results Domestic shorthair cats (48%) and Maine Coons (37%) were over-represented. The most common presenting clinical signs were otorrhoea, ear scratching and head shaking. Video-otoscopic examination confirmed a polypous mass in the ear canal in all patients. All 62 cats underwent TALA, with a mean surgical time of 33 mins for experienced surgeons (n = 4) and 48 mins (n = 12) for less experienced surgeons. The recurrence rate of polyp regrowth for experienced surgeons was 14.3% vs 35% for the less experienced surgeons. Postoperative complications included Horner's syndrome (11.5%) and facial nerve paralysis (3%). Otitis interna was not observed. Conclusions and relevance A lateral approach to the ear canal in combination with deep TA of an aural inflammatory polyp is an effective first-line technique that results in a low recurrence and complication rate.

  17. In situ electrochemical investigations of the kinetic and thermodynamic properties of nickel-metal hydride traction batteries

    NASA Astrophysics Data System (ADS)

    Yang, Xiao Guang; Liaw, Bor Yann

    Although large ampere hour nickel-metal hydride (Ni-MH) traction batteries are in the stage of being commercialized for electric and hybrid vehicle applications, little is known about their performance characteristics. By using a standard Hg/HgO reference electrode in a commercial Ni-MH battery, we were able to conduct in situ measurements to determine both kinetic and thermodynamic properties of the system, including the characteristics of individual electrodes. Using the galvanostatic intermittent titration technique (GITT), we simultaneously and effectively determined the open-circuit voltage of the battery, the equilibrium electrode potentials, and the diffusion coefficient of proton and hydrogen in the nickel and metal hydride electrode, respectively, as a function of the states of charge (SOC). Using the current-step excitation technique, we found that the internal resistance of the battery primarily comes from the metal hydride electrode, which is greater by one order of magnitude than that of the Ni electrode. The cyclic linear micro-polarization experiments, on the other hand, showed that the charge-transfer resistance of the electrochemical reaction at the metal hydride electrode is about twice larger than that of the Ni counterpart above 20% SOC. In comparison, the internal resistance is an order of magnitude smaller than those of the electrochemical charge-transfer reactions. The micro-polarization technique also allowed us to calculate the exchange current densities of the respective electrode electrochemical reactions and the associated specific exchange current densities. These in situ, simple but detailed, characterizations of the thermodynamic and kinetic properties of the Ni-MH system provided valuable information for better understanding of the battery performance.

  18. Review of economic studies and budget impact analysis of ocriplasmin as a treatment of vitreomacular traction.

    PubMed

    García-Pérez, L; Abreu-González, R; Pérez-Ramos, J; García-Pérez, S; Serrano-Aguilar, P

    2016-06-01

    To review the evidence on the cost-effectiveness of ocriplasmin as a treatment for vitreomacular traction (VMT), and to estimate the impact on the Spanish National Health System (NHS). 1) Systematic review. The following databases were searched in January 2015: MEDLINE, PREMEDLINE, EMBASE, CRD, the Cochrane Library, and key websites. Selection criteria were: full economic evaluations that compared ocriplasmin with usual care ('watch and wait' and/or vitrectomy) in patients with VMT. The outcomes to extract were costs of the alternatives and the incremental cost-effectiveness ratio. Studies of budget impact analysis were also included. The methodological quality was assessed, and a narrative synthesis of the included studies was carried out. 2) Estimation of budget impact. The impact on the budget as a result of the introduction of ocriplasmin in the NHS was estimated, including data from different sources. Six studies were identified, none of them performed in Spain. The two best studies concluded that ocriplasmin is cost-effective in their respective countries (Canada and United Kingdom), but only in patients with certain conditions (without epiretinal membrane, for example). The results of the budget impact analysis are different between countries. The analysis for Spain showed that the introduction of ocriplasmin would mean a saving over 1 million Euros for the NHS in 5 years. The cost-effectiveness of ocriplasmin has not been demonstrated in Spain. However, good studies performed in other countries found that ocriplasmin is cost-effective in selected patients. Given the current prices in Spain, ocriplasmin could involve a saving for the Spanish NHS. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Multirole cargo aircraft options and configurations. [economic analysis

    NASA Technical Reports Server (NTRS)

    Conner, D. W.; Vaughan, J. C., III

    1979-01-01

    A future requirements and advanced market evaluation study indicates derivatives of current wide-body aircraft, using 1980 advanced technology, would be economically attractive through 2008, but new dedicated airfreighters incorporating 1990 technology, would offer little or no economic incentive. They would be economically attractive for all payload sizes, however, if RD and T costs could be shared in a joint civil/military arrangement. For the 1994-2008 cargo market, option studies indicate Mach 0.7 propfans would be economically attractive in trip cost, aircraft price and airline ROI. Spanloaders would have an even lower price and higher ROI but would have a relatively high trip cost because of aerodynamic inefficiencies. Dedicated airfreighters using propfans at Mach 0.8 cruise, laminar flow control, or cryofuels, would not provide any great economic benefits. Air cushion landing gear configurations are identified as an option for avoiding runway constraints on airport requirements and/or operational constraints are noted.

  20. Etude par resistivite electrique du comportement d'un alliage amorphe Fe 40Ni 38Mo 4B 18 deforme par traction

    NASA Astrophysics Data System (ADS)

    Hoang, Long Phan; Sacovy, Paulette; Delaplace, Jean

    1983-02-01

    Des rubans d'alliages amorphes Metglas du type Fe 40Ni 38Mo 4B 18 à l'état brut de trempe ont été déformés par traction à la température ambiante et l'on a suivi les variations de la résistance électrique des échantillons au cours de la déformation. Il ressort de ces essais que la déformation plastique qui est de l'ordre de 0.5% avant rupture ne se produit pas de faĉon homogène dans l'échantillon. Les mesures électriques effectuées au cours de la déformation mettent en évidence dans le domaine élastique un effet d'élastorésistance, relativement important ( K ≠ 1); elles montrent que dans le domaine plastique la déformation permanente des échantillons s'accompagne d'une diminution de la résistivité électrique du matériau. Deux hypothèses sont discutées pour expliquer cet effet inattendu, l'un qui fait appel à l'existence de volumes libres, l'autre qui suppose une cristallisation localisée du matériau sous l'effet de la contrainte.

  1. Termination of atrial spiral waves by traction into peripheral non 1:1 conducting regions - A numerical study.

    PubMed

    Rozner, Amit; Zlochiver, Sharon

    2016-11-01

    Atrial ablation has been recently utilized to treat atrial fibrillation (AF) by isolation or destruction of arrhythmia drivers. In chronic or persistent AF patients these drivers often consist of one or few rotors at unknown locations, and several ablations are commonly conducted before arrhythmia is terminated. However, the irreversible damage done to the tissue may lead to AF recurrence. We propose an alternative strategy to terminate rotor activity by its attraction into a non 1:1 conducting region. The feasibility of the method was numerically tested in 2D models of chronic AF human atrial tissue. Left-to-right gradients of either acetylcholine (ACh) or potassium conductance were employed to generate regions of 1:1 and non 1:1 conduction, characterized by their dominant frequency (DF) ratios. Spiral waves were established in the 1:1 conducting region and raster scanning was employed using a stimulating probe to attract the spiral wave tip. The probe was then linearly moved towards the boundary between the two regions. Successful attraction of spiral waves to the probe was demonstrated when the probe was <8mm from the spiral wave tip. Maximal traction velocity without loss of anchoring increased in a non-linear way with increasing values of ACh. Success rate of spiral wave termination was over 90% for regional DF ratios of as low as 1:1.2. Given that normally much higher ratios are measured in physiological atrial tissues, we envision this technique to provide a feasible, safer alternative to ablation procedures performed in persistent AF patients. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Revealing Asymmetries in the HD181327 Debris Disk: A Recent Massive Collision or Interstellar Medium Warping

    NASA Technical Reports Server (NTRS)

    Stark, Christopher C.; Schneider, Glenn; Weinberger, Alycia J.; Debes, John H.; Grady, Carol A.; Jang-Condell, Hannah; Kuchner, Marc J.

    2014-01-01

    New multi-roll coronagraphic images of the HD181327 debris disk obtained using the Space Telescope Imaging Spectrograph on board the Hubble Space Telescope reveal the debris ring in its entirety at high signal-to-noise ratio and unprecedented spatial resolution. We present and apply a new multi-roll image processing routine to identify and further remove quasi-static point-spread function-subtraction residuals and quantify systematic uncertainties. We also use a new iterative image deprojection technique to constrain the true disk geometry and aggressively remove any surface brightness asymmetries that can be explained without invoking dust density enhancements/ deficits. The measured empirical scattering phase function for the disk is more forward scattering than previously thought and is not well-fit by a Henyey-Greenstein function. The empirical scattering phase function varies with stellocentric distance, consistent with the expected radiation pressured-induced size segregation exterior to the belt. Within the belt, the empirical scattering phase function contradicts unperturbed debris ring models, suggesting the presence of an unseen planet. The radial profile of the flux density is degenerate with a radially varying scattering phase function; therefore estimates of the ring's true width and edge slope may be highly uncertain.We detect large scale asymmetries in the disk, consistent with either the recent catastrophic disruption of a body with mass greater than 1% the mass of Pluto, or disk warping due to strong interactions with the interstellar medium.

  3. X-ray Studies of Regenerated Cellulose Fibers Wet Spun from Cotton Linter Pulp in NaOH/Thiourea Aqueous Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen,X.; Burger, C.; Fang, D.

    Regenerated cellulose fibers were fabricated by dissolution of cotton linter pulp in NaOH (9.5 wt%) and thiourea (4.5 wt%) aqueous solution followed by wet-spinning and multi-roller drawing. The multi-roller drawing process involved three stages: coagulation (I), coagulation (II) and post-treatment (III). The crystalline structure and morphology of regenerated cellulose fiber was investigated by synchrotron wide-angle X-ray diffraction (WAXD) and small-angle X-ray scattering (SAXS) techniques. Results indicated that only the cellulose II crystal structure was found in regenerated cellulose fibers, proving that the cellulose crystals were completely transformed from cellulose I to II structure during spinning from NaOH/thiourea aqueous solution. Themore » crystallinity, orientation and crystal size at each stage were determined from the WAXD analysis. Drawing of cellulose fibers in the coagulation (II) bath (H{sub 2}SO{sub 4}/H{sub 2}O) was found to generate higher orientation and crystallinity than drawing in the post-treatment (III). Although the post-treatment process also increased crystal orientation, it led to a decrease in crystallinity with notable reduction in the anisotropic fraction. Compared with commercial rayon fibers fabricated by the viscose process, the regenerated cellulose fibers exhibited higher crystallinity but lower crystal orientation. SAXS results revealed a clear scattering maximum along the meridian direction in all regenerated cellulose fibers, indicating the formation of lamellar structure during spinning.« less

  4. Revealing asymmetries in the HD 181327 debris disk: A recent massive collision or interstellar medium warping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stark, Christopher C.; Kuchner, Marc J.; Schneider, Glenn

    New multi-roll coronagraphic images of the HD 181327 debris disk obtained using the Space Telescope Imaging Spectrograph on board the Hubble Space Telescope reveal the debris ring in its entirety at high signal-to-noise ratio and unprecedented spatial resolution. We present and apply a new multi-roll image processing routine to identify and further remove quasi-static point-spread function-subtraction residuals and quantify systematic uncertainties. We also use a new iterative image deprojection technique to constrain the true disk geometry and aggressively remove any surface brightness asymmetries that can be explained without invoking dust density enhancements/deficits. The measured empirical scattering phase function for themore » disk is more forward scattering than previously thought and is not well-fit by a Henyey-Greenstein function. The empirical scattering phase function varies with stellocentric distance, consistent with the expected radiation pressured-induced size segregation exterior to the belt. Within the belt, the empirical scattering phase function contradicts unperturbed debris ring models, suggesting the presence of an unseen planet. The radial profile of the flux density is degenerate with a radially varying scattering phase function; therefore estimates of the ring's true width and edge slope may be highly uncertain. We detect large scale asymmetries in the disk, consistent with either the recent catastrophic disruption of a body with mass >1% the mass of Pluto, or disk warping due to strong interactions with the interstellar medium.« less

  5. Revealing Asymmetries in the HD 181327 Debris Disk: A Recent Massive Collision or Interstellar Medium Warping

    NASA Astrophysics Data System (ADS)

    Stark, Christopher C.; Schneider, Glenn; Weinberger, Alycia J.; Debes, John H.; Grady, Carol A.; Jang-Condell, Hannah; Kuchner, Marc J.

    2014-07-01

    New multi-roll coronagraphic images of the HD 181327 debris disk obtained using the Space Telescope Imaging Spectrograph on board the Hubble Space Telescope reveal the debris ring in its entirety at high signal-to-noise ratio and unprecedented spatial resolution. We present and apply a new multi-roll image processing routine to identify and further remove quasi-static point-spread function-subtraction residuals and quantify systematic uncertainties. We also use a new iterative image deprojection technique to constrain the true disk geometry and aggressively remove any surface brightness asymmetries that can be explained without invoking dust density enhancements/deficits. The measured empirical scattering phase function for the disk is more forward scattering than previously thought and is not well-fit by a Henyey-Greenstein function. The empirical scattering phase function varies with stellocentric distance, consistent with the expected radiation pressured-induced size segregation exterior to the belt. Within the belt, the empirical scattering phase function contradicts unperturbed debris ring models, suggesting the presence of an unseen planet. The radial profile of the flux density is degenerate with a radially varying scattering phase function; therefore estimates of the ring's true width and edge slope may be highly uncertain. We detect large scale asymmetries in the disk, consistent with either the recent catastrophic disruption of a body with mass >1% the mass of Pluto, or disk warping due to strong interactions with the interstellar medium.

  6. Direct cost of pars plana vitrectomy for the treatment of macular hole, epiretinal membrane and vitreomacular traction: a bottom-up approach.

    PubMed

    Nicod, Elena; Jackson, Timothy L; Grimaccia, Federico; Angelis, Aris; Costen, Marc; Haynes, Richard; Hughes, Edward; Pringle, Edward; Zambarakji, Hadi; Kanavos, Panos

    2016-11-01

    The direct cost to the National Health Service (NHS) in England of pars plana vitrectomy (PPV) is unknown since a bottom-up costing exercise has not been undertaken. Healthcare resource group (HRG) costing relies on a top-down approach. We aimed to quantify the direct cost of intermediate complexity PPV. Five NHS vitreoretinal units prospectively recorded all consumables, equipment and staff salaries during PPV undertaken for vitreomacular traction, epiretinal membrane and macular hole. Out-of-surgery costs between admission and discharge were estimated using a representative accounting method. The average patient time in theatre for 57 PPVs was 72 min. The average in-surgery cost for staff was £297, consumables £619, and equipment £82 (total £997). The average out-of-surgery costs were £260, including nursing and medical staff, other consumables, eye drops and hospitalisation. The total cost was therefore £1634, including 30 % overheads. This cost estimate was an under-estimate because it did not include out-of-theatre consumables or equipment. The average reimbursed HRG tariff was £1701. The cost of undertaking PPV of intermediate complexity is likely to be higher than the reimbursed tariff, except for hospitals with high throughput, where amortisation costs benefit from economies of scale. Although this research was set in England, the methodology may provide a useful template for other countries.

  7. 3D display considerations for rugged airborne environments

    NASA Astrophysics Data System (ADS)

    Barnidge, Tracy J.; Tchon, Joseph L.

    2015-05-01

    The KC-46 is the next generation, multi-role, aerial refueling tanker aircraft being developed by Boeing for the United States Air Force. Rockwell Collins has developed the Remote Vision System (RVS) that supports aerial refueling operations under a variety of conditions. The system utilizes large-area, high-resolution 3D displays linked with remote sensors to enhance the operator's visual acuity for precise aerial refueling control. This paper reviews the design considerations, trade-offs, and other factors related to the selection and ruggedization of the 3D display technology for this military application.

  8. Intelligence Support for the F-35A Lightning II

    DTIC Science & Technology

    2016-01-01

    106 | Air & Space Power Journal Intelligence Support for the F-35A Lightning II Capt Stephanie Anne Fraioli, USAF Disclaimer: The views and opinions...reproduced in whole or in part without permission. If it is reproduced, the Air and Space Power Journal requests a courtesy line. The F-35 Lightning II is...airspace. Specifi- cally, the F-35 Lightning II is advertised as a multirole follow-on to the A-10, AV-8B, F-16, and F/A-18A/B/C/D aircraft. The F-35 is

  9. Integrin-mediated traction force enhances paxillin molecular associations and adhesion dynamics that increase the invasiveness of tumor cells into a three-dimensional extracellular matrix

    PubMed Central

    Mekhdjian, Armen H.; Kai, FuiBoon; Rubashkin, Matthew G.; Prahl, Louis S.; Przybyla, Laralynne M.; McGregor, Alexandra L.; Bell, Emily S.; Barnes, J. Matthew; DuFort, Christopher C.; Ou, Guanqing; Chang, Alice C.; Cassereau, Luke; Tan, Steven J.; Pickup, Michael W.; Lakins, Jonathan N.; Ye, Xin; Davidson, Michael W.; Lammerding, Jan; Odde, David J.; Dunn, Alexander R.; Weaver, Valerie M.

    2017-01-01

    Metastasis requires tumor cells to navigate through a stiff stroma and squeeze through confined microenvironments. Whether tumors exploit unique biophysical properties to metastasize remains unclear. Data show that invading mammary tumor cells, when cultured in a stiffened three-dimensional extracellular matrix that recapitulates the primary tumor stroma, adopt a basal-like phenotype. Metastatic tumor cells and basal-like tumor cells exert higher integrin-mediated traction forces at the bulk and molecular levels, consistent with a motor-clutch model in which motors and clutches are both increased. Basal-like nonmalignant mammary epithelial cells also display an altered integrin adhesion molecular organization at the nanoscale and recruit a suite of paxillin-associated proteins implicated in invasion and metastasis. Phosphorylation of paxillin by Src family kinases, which regulates adhesion turnover, is similarly enhanced in the metastatic and basal-like tumor cells, fostered by a stiff matrix, and critical for tumor cell invasion in our assays. Bioinformatics reveals an unappreciated relationship between Src kinases, paxillin, and survival of breast cancer patients. Thus adoption of the basal-like adhesion phenotype may favor the recruitment of molecules that facilitate tumor metastasis to integrin-based adhesions. Analysis of the physical properties of tumor cells and integrin adhesion composition in biopsies may be predictive of patient outcome. PMID:28381423

  10. Surface temperatures and glassy state investigations in tribology, part 5

    NASA Technical Reports Server (NTRS)

    Bair, S.; Winer, W. O.

    1982-01-01

    Preliminary measurements of high shear rate viscosity at near atmospheric but variable pressure suggest the importance of low normal stress and cavitation or fluid fracture in the type of stress field existing in elastohydrodynam ic inlets and classical hydrodynamic configurations. An experimental basis is given for three regimes of traction in concentrated contacts: a thin film regime characterized by high traction and determined by lambda ratio, a thick film regime characterized by low traction and determined by the speed parameter, and the elastohydrodynamic regime for which traction is controlled by limiting shear stress. Traction measurements were performed with various liquids, two solid lubricants, and a grease. Film thickness and traction measurements of polymer blends and base oils are compared.

  11. Graining Traction

    ERIC Educational Resources Information Center

    James, Joan K.; Matthews, Robert W.

    2017-01-01

    In their classrooms, the authors observed students experiencing meaningful and memorable learning when they were immersed in scientific inquiry involving Bess beetles. Students who learn from active, experiential instruction, find such learning to be exciting and emotionally engaging. As a result, they learn more deeply and effectively. This…

  12. AN/ASQ-197 provides commonality to Recce systems and avionics upgrades

    NASA Astrophysics Data System (ADS)

    Regan, Brendan P.

    1993-02-01

    In an attempt to strike a balance between increases in multi-role tactical air reconnaissance mission tasking and simultaneous decreases in defense spending, many users are evaluating upgrades to existing sensors and reconnaissance systems. At the heart of any cost-effective reconnaissance system upgrade must be a flexible reconnaissance management system, capable of filling multiple rolls in today's film backed reconnaissance system, while enabling successful transition to the Electro-Optical (EO) system of tomorrow. As a case in point this paper describes enhanced effectiveness and growth potential that Fairchild's AN/ASQ-197 Sensor Control-Data Display Set (SC-DDS) can provide.

  13. Intradiscal Pressure Changes during Manual Cervical Distraction: A Cadaveric Study

    PubMed Central

    Gudavalli, M. R.; Potluri, T.; Carandang, G.; Havey, R. M.; Voronov, L. I.; Cox, J. M.; Rowell, R. M.; Kruse, R. A.; Joachim, G. C.; Patwardhan, A. G.; Henderson, C. N. R.; Goertz, C.

    2013-01-01

    The objective of this study was to measure intradiscal pressure (IDP) changes in the lower cervical spine during a manual cervical distraction (MCD) procedure. Incisions were made anteriorly, and pressure transducers were inserted into each nucleus at lower cervical discs. Four skilled doctors of chiropractic (DCs) performed MCD procedure on nine specimens in prone position with contacts at C5 or at C6 vertebrae with the headpiece in different positions. IDP changes, traction forces, and manually applied posterior-to-anterior forces were analyzed using descriptive statistics. IDP decreases were observed during MCD procedure at all lower cervical levels C4-C5, C5-C6, and C6-C7. The mean IDP decreases were as high as 168.7 KPa. Mean traction forces were as high as 119.2 N. Posterior-to-anterior forces applied during manual traction were as high as 82.6 N. Intraclinician reliability for IDP decrease was high for all four DCs. While two DCs had high intraclinician reliability for applied traction force, the other two DCs demonstrated only moderate reliability. IDP decreases were greatest during moving flexion and traction. They were progressevely less pronouced with neutral traction, fixed flexion and traction, and generalized traction. PMID:24023587

  14. Solid lubrication design methodology

    NASA Technical Reports Server (NTRS)

    Aggarwal, B. B.; Yonushonis, T. M.; Bovenkerk, R. L.

    1984-01-01

    A single element traction rig was used to measure the traction forces at the contact of a ball against a flat disc at room temperature under combined rolling and sliding. The load and speed conditions were selected to match those anticipated for bearing applications in adiabatic diesel engines. The test program showed that the magnitude of traction forces were almost the same for all the lubricants tested; a lubricant should, therefore, be selected on the basis of its ability to prevent wear of the contact surfaces. Traction vs. slide/roll ratio curves were similar to those for liquid lubricants but the traction forces were an order of magnitude higher. The test data was used to derive equations to predict traction force as a function of contact stress and rolling speed. Qualitative design guidelines for solid lubricated concentrated contacts are proposed.

  15. A tyre slip-based integrated chassis control of front/rear traction distribution and four-wheel independent brake from moderate driving to limit handling

    NASA Astrophysics Data System (ADS)

    Joa, Eunhyek; Park, Kwanwoo; Koh, Youngil; Yi, Kyongsu; Kim, Kilsoo

    2018-04-01

    This paper presents a tyre slip-based integrated chassis control of front/rear traction distribution and four-wheel braking for enhanced performance from moderate driving to limit handling. The proposed algorithm adopted hierarchical structure: supervisor - desired motion tracking controller - optimisation-based control allocation. In the supervisor, by considering transient cornering characteristics, desired vehicle motion is calculated. In the desired motion tracking controller, in order to track desired vehicle motion, virtual control input is determined in the manner of sliding mode control. In the control allocation, virtual control input is allocated to minimise cost function. The cost function consists of two major parts. First part is a slip-based tyre friction utilisation quantification, which does not need a tyre force estimation. Second part is an allocation guideline, which guides optimally allocated inputs to predefined solution. The proposed algorithm has been investigated via simulation from moderate driving to limit handling scenario. Compared to Base and direct yaw moment control system, the proposed algorithm can effectively reduce tyre dissipation energy in the moderate driving situation. Moreover, the proposed algorithm enhances limit handling performance compared to Base and direct yaw moment control system. In addition to comparison with Base and direct yaw moment control, comparison the proposed algorithm with the control algorithm based on the known tyre force information has been conducted. The results show that the performance of the proposed algorithm is similar with that of the control algorithm with the known tyre force information.

  16. Open Abdomen Therapy with Vacuum and Mesh Mediated Fascial Traction After Aortic Repair: an International Multicentre Study.

    PubMed

    Acosta, Stefan; Seternes, Arne; Venermo, Maarit; Vikatmaa, Leena; Sörelius, Karl; Wanhainen, Anders; Svensson, Mats; Djavani, Khatereh; Björck, Martin

    2017-12-01

    Open abdomen therapy may be necessary to prevent or treat abdominal compartment syndrome (ACS). The aim of the study was to analyse the primary delayed fascial closure (PDFC) rate and complications after open abdomen therapy with vacuum and mesh mediated fascial traction (VACM) after aortic repair and to compare outcomes between those treated with open abdomen after primary versus secondary operation. This was a retrospective cohort, multicentre study in Sweden, Finland, and Norway, including consecutive patients treated with open abdomen and VACM after aortic repair at six vascular centres in 2006-2015. The primary endpoint was PDFC rate. Among 191 patients, 155 were men. The median age was 71 years (IQR 66-76). Ruptured abdominal aortic aneurysm (RAAA) occurred in 69.1%. Endovascular/hybrid and open repairs were performed in 49 and 142 patients, respectively. The indications for open abdomen were inability to close the abdomen (62%) at primary operation and ACS (80%) at secondary operation. Duration of open abdomen was 11 days (IQR 7-16) in 157 patients alive at open abdomen termination. The PDFC rate was 91.8%. Open abdomen initiated at primary (N=103), compared with secondary operation (N=88), was associated with less severe initial open abdomen status (p=.006), less intestinal ischaemia (p=.002), shorter duration of open abdomen (p=.007), and less renal replacement therapy (RRT, p<.001). In hospital mortality was 39.3%, and after entero-atmospheric fistula (N=9) was 88.9%. Seven developed graft infection within 6 months, 1 year mortality was 28.6%. Intestinal ischaemia (OR 3.71, 95% CI 1.55-8.91), RRT (OR 3.62, 95% CI 1.72-7.65), and age (OR 1.12, 95% CI 1.06-1.12), were independent factors associated with in hospital mortality, but not open abdomen initiated at primary versus secondary operation. VACM was associated with a high PDFC rate after prolonged open abdomen therapy following aortic repair. Patient outcomes seemed better when open abdomen was

  17. Case report: Osteonecrosis of the femoral head after hip arthroscopy.

    PubMed

    Scher, Danielle L; Belmont, Philip J; Owens, Brett D

    2010-11-01

    Hip arthroscopy is a common orthopaedic procedure used as a diagnostic and therapeutic tool with a multitude of surgical indications. The complication rate is reportedly between 1.3% and 23.3%. Major complications are related to traction, fluid extravasation, and iatrogenic chondral injury. Although osteonecrosis is a concern with any surgical procedure about the hip, this complication has been primarily a theoretical concern with hip arthroscopy. We report the case of a 24-year-old man who presented with a 2-year history of left hip pain. He underwent hip arthroscopy to include débridement of a torn labrum and removal of a prominent pincer lesion for femoroacetabular impingement. Traction was initiated by applying manual traction to the traction bar until 10 mm of joint distraction was obtained. Traction was removed at 90 minutes. At the 3-month followup, MRI showed osteonecrosis in the subcapital region of the left femoral head. It generally is agreed the magnitude and duration of traction during hip arthroscopy increase the risk of traction-related injuries. Only one previous case of femoral head osteonecrosis associated with hip arthroscopy has been reported, and this may have resulted from the initial traumatic event. Based on anatomic studies, the use of standard arthroscopic portals would not put at risk any dominant normal vascular structures supplying the femoral head. In contrast, the literature shows that femoral head osteonecrosis may develop secondary to a combination of increased intraarticular pressure and traction. We suspect this case of femoral head osteonecrosis after hip arthroscopy was caused by traction used in the procedure.

  18. Auxiliary power unit for moving a vehicle

    DOEpatents

    Akasam, Sivaprasad [Peoria, IL; Johnson, Kris W [Peoria, IL; Johnson, Matthew D [Peoria, IL; Slone, Larry M [Washington, IL; Welter, James Milton [Chillicothe, IL

    2009-02-03

    A power system is provided having at least one traction device and a primary power source configured to power the at least one traction device. In addition, the power system includes an auxiliary power source also configured to power the at least one traction device.

  19. Fluidization, resolidification, and reorientation of the endothelial cell in response to slow tidal stretches

    PubMed Central

    Krishnan, Ramaswamy; Canović, Elizabeth Peruski; Iordan, Andreea L.; Rajendran, Kavitha; Manomohan, Greeshma; Pirentis, Athanassios P.; Smith, Michael L.; Butler, James P.; Fredberg, Jeffrey J.

    2012-01-01

    Mechanical stretch plays an important role in regulating shape and orientation of the vascular endothelial cell. This morphological response to stretch is basic to angiogenesis, neovascularization, and vascular homeostasis, but mechanism remains unclear. To elucidate mechanisms, we used cell mapping rheometry to measure traction forces in primary human umbilical vein endothelial cells subjected to periodic uniaxial stretches. Onset of periodic stretch of 10% strain amplitude caused a fluidization response typified by attenuation of traction forces almost to zero. As periodic stretch continued, the prompt fluidization response was followed by a slow resolidification response typified by recovery of the traction forces, but now aligned along the axis perpendicular to the imposed stretch. Reorientation of the cell body lagged reorientation of the traction forces, however. Together, these observations demonstrate that cellular reorientation in response to periodic stretch is preceded by traction attenuation by means of cytoskeletal fluidization and subsequent traction recovery transverse to the stretch direction by means of cytoskeletal resolidification. PMID:22700796

  20. Screw-Wire Osteo-Traction: An Adjunctive or Alternative Method of Anatomical Reduction of Multisegment Midfacial Fractures? A Description of Technique and Prospective Study of 40 Patients

    PubMed Central

    O'Regan, Barry; Devine, Maria; Bhopal, Sats

    2013-01-01

    Stable anatomical fracture reduction and segment control before miniplate fixation can be difficult to achieve in comminuted midfacial fractures. Fracture mobilization and reduction methods include Gillies elevation, malar hook, and Dingman elevators. No single method is used universally. Disadvantages include imprecise segment alignment and poor segment stability/control. We have employed screw-wire osteo-traction (SWOT) to address this problem. A literature review revealed two published reports. The aims were to evaluate the SWOT technique effectiveness as a fracture reduction method and to examine rates of revision fixation and plate removal. We recruited 40 consecutive patients requiring open reduction and internal fixation of multisegment midfacial fractures (2009–2012) and employed miniplate osteosynthesis in all patients. SWOT was used as a default reduction method in all patients. The rates of successful fracture reduction achieved by SWOT alone or in combination and of revision fixation and plate removal, were used as outcome indices of the reduction method effectiveness. The SWOT technique achieved satisfactory anatomical reduction in 27/40 patients when used alone. Other reduction methods were also used in 13/40 patients. No patient required revision fixation and three patients required late plate removal. SWOT can be used across the midface fracture pattern in conjunction with other methods or as a sole reduction method before miniplate fixation. PMID:24436763

  1. Influence des elements d'addition Ti, Nb, Al sur la structure et les proprietes mecaniques en traction et en fluage (de 298 A 1023 K) des alliages a base de fer et de nickel du type IN 706

    NASA Astrophysics Data System (ADS)

    Aubert, H.; Laniesse, J.; Lelong, C.; Pigoury, M.

    1981-09-01

    L'étude a porté sur 13 alliages du type IN 706 dont un alliage commercial et des alliages expérimentaux ayant une teneur en éléments durcissants niobium, titane, aluminium assez différente de celle de la nuance commerciale. On montre l'effet de la composition sur la structure et sur la cinétique de précipitation des phases stables et métastables. On décrit les propriétés mécaniques à l'état précipité: dureté, résistance à la traction, caractéristiques de fluage. Il est conclu que des alliages relativement pauvres en éléments durcissants peuvent convenir à la rélisation de gaines pour les réacteurs à neutrons rapides.

  2. Comparison of clinical outcomes of multi-point umbrella suturing and single purse suturing with two-point traction after procedure for prolapse and hemorrhoids (PPH) surgery.

    PubMed

    Jiang, Huiyong; Hao, Xiuyan; Xin, Ying; Pan, Youzhen

    2017-11-01

    To compare the clinical outcomes of multipoint umbrella suture and single-purse suture with two-point traction after procedure for prolapse and hemorrhoids surgery (PPH) for the treatment of mixed hemorrhoids. Ninety patients were randomly divided into a PPH plus single-purse suture group (Group A) and a PPH plus multipoint umbrella suture (Group B). All operations were performed by an experienced surgeon. Operation time, width of the specimen, hemorrhoids retraction extent, postoperative pain, postoperative bleeding, and length of hospitalization were recorded and compared. Statistical analysis was conducted by t-test and χ2 test. There were no significant differences in sex, age, course of disease, and degree of prolapse of hemorrhoids between the two groups. The operative time in Group A was significantly shorter than that in Group B (P < 0.05). However, the incidence rates of submucosal hematoma and incomplete hemorrhoid core retraction were significantly lower in Group B (P < 0.05), whereas the width of the specimens in Group B was greater than that in Group A (P < 0.05). There were fewer redundant skin tags in Group B at three months follow-up. No significant difference in postoperative pain, postoperative bleeding, and time of hospital stay (P > 0.05 for all comparisons) was observed. The multipoint umbrella suture showed better clinical outcomes because of its targeted suture according to the extent of hemorrhoid prolapse. Copyright © 2017. Published by Elsevier Ltd.

  3. Evaluation of force degradation characteristics of orthodontic latex elastics in vitro and in vivo.

    PubMed

    Wang, Tong; Zhou, Gang; Tan, Xianfeng; Dong, Yaojun

    2007-07-01

    To evaluate the characteristics of force degradation of latex elastics in clinical applications and in vitro studies. Samples of 3/16-inch latex elastics were investigated, and 12 students between the ages of 12 and 15 years were selected for the intermaxillary and intramaxillary tractions. The elastics in the control groups were set in artificial saliva and dry room conditions and were stretched 20 mm. The repeated-measure two-way analysis of variance and nonlinear regression analysis were used to identify statistical significance. Overall, there were statistically significant differences between the different methods and observation intervals. At 24- and 48-hour time intervals, the force decreased during in vivo testing and in artificial saliva (P < .001), whereas there were no significant differences in dry room conditions (P > .05). In intermaxillary traction the percentage of initial force remaining after 48 hours was 61%. In intramaxillary traction and in artificial saliva the percentage of initial force remaining was 71%, and in room conditions 86% of initial force remained. Force degradation of latex elastics was different according to their environmental conditions. There was significantly more force degradation in intermaxillary traction than in intramaxillary traction. The dry room condition caused the least force loss. There were some differences among groups in the different times to start wearing elastics in intermaxillary traction but no significant differences in intramaxillary traction.

  4. Development of a measurement system for the mechanical load of functional appliances.

    PubMed

    Shimazaki, Aya; Kimura, Hitoshi; Inou, Norio; Maki, Koutaro

    2017-10-03

    Devices called functional appliances are commonly used in orthodontics for treating maxillary protrusion. These devices mechanically force the mandible forward to apply traction force to the mandibular condyle. This promotes cartilaginous growth in the small mandible. However, no studies have clarified how much traction force is applied to the mandibular condyle. Moreover, it remains unknown as to how anatomical characteristics affect this traction force. Therefore, in this study, we developed a device for measuring the amount of force generated while individual patients wore functional appliances, and we investigated the relationship between forces with structures surrounding the mandibular condyle. We compared traction force values with cone-beam computed tomography image data in eight subjects. The functional appliance resulted in a traction force of 339-1477gf/mm, with a mean value of 196.5gf/mm for the elastic modulus of the mandible. A comparison with cone-beam computed tomography image data suggested that the mandibular traction force was affected by the mandibular condyle and shape of the articular eminence. This method can contribute to discovering efficient treatment techniques more suited to individual patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The Multirole of Liposomes in Therapy and Prevention of Infectious Diseases

    PubMed Central

    Nisini, Roberto; Poerio, Noemi; Mariotti, Sabrina; De Santis, Federica; Fraziano, Maurizio

    2018-01-01

    Liposomes are closed bilayer structures spontaneously formed by hydrated phospholipids that are widely used as efficient delivery systems for drugs or antigens, due to their capability to encapsulate bioactive hydrophilic, amphipathic, and lipophilic molecules into inner water phase or within lipid leaflets. The efficacy of liposomes as drug or antigen carriers has been improved in the last years to ameliorate pharmacokinetics and capacity to release their cargo in selected target organs or cells. Moreover, different formulations and variations in liposome composition have been often proposed to include immunostimulatory molecules, ligands for specific receptors, or stimuli responsive compounds. Intriguingly, independent research has unveiled the capacity of several phospholipids to play critical roles as intracellular messengers in modulating both innate and adaptive immune responses through various mechanisms, including (i) activation of different antimicrobial enzymatic pathways, (ii) driving the fusion–fission events between endosomes with direct consequences to phagosome maturation and/or to antigen presentation pathway, and (iii) modulation of the inflammatory response. These features can be exploited by including selected bioactive phospholipids in the bilayer scaffold of liposomes. This would represent an important step forward since drug or antigen carrying liposomes could be engineered to simultaneously activate different signal transduction pathways and target specific cells or tissues to induce antigen-specific T and/or B cell response. This lipid-based host-directed strategy can provide a focused antimicrobial innate and adaptive immune response against specific pathogens and offer a novel prophylactic or therapeutic option against chronic, recurrent, or drug-resistant infections. PMID:29459867

  6. Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

    PubMed Central

    Song, Jae-Won; Lim, Joong-Ki; Lee, Kee-Joon; Sung, Sang-Jin; Chun, Youn-Sic

    2016-01-01

    Objective Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion. PMID:27478801

  7. Force Mapping during the Formation and Maturation of Cell Adhesion Sites with Multiple Optical Tweezers

    PubMed Central

    Schwingel, Melanie; Bastmeyer, Martin

    2013-01-01

    Focal contacts act as mechanosensors allowing cells to respond to their biomechanical environment. Force transmission through newly formed contact sites is a highly dynamic process requiring a stable link between the intracellular cytoskeleton and the extracellular environment. To simultaneously investigate cellular traction forces in several individual maturing adhesion sites within the same cell, we established a custom-built multiple trap optical tweezers setup. Beads functionalized with fibronectin or RGD-peptides were placed onto the apical surface of a cell and trapped with a maximum force of 160 pN. Cells form adhesion contacts around the beads as demonstrated by vinculin accumulation and start to apply traction forces after 30 seconds. Force transmission was found to strongly depend on bead size, surface density of integrin ligands and bead location on the cell surface. Highest traction forces were measured for beads positioned on the leading edge. For mouse embryonic fibroblasts, traction forces acting on single beads are in the range of 80 pN after 5 minutes. If two beads were positioned parallel to the leading edge and with a center-to-center distance less than 10 µm, traction forces acting on single beads were reduced by 40%. This indicates a spatial and temporal coordination of force development in closely related adhesion sites. We also used our setup to compare traction forces, retrograde transport velocities, and migration velocities between two cell lines (mouse melanoma and fibroblasts) and primary chick fibroblasts. We find that maximal force development differs considerably between the three cell types with the primary cells being the strongest. In addition, we observe a linear relation between force and retrograde transport velocity: a high retrograde transport velocity is associated with strong cellular traction forces. In contrast, migration velocity is inversely related to traction forces and retrograde transport velocity. PMID:23372781

  8. Influence of AC system design on the realisation of tractive efforts by high adhesion locomotives

    NASA Astrophysics Data System (ADS)

    Spiryagin, Maksym; Wolfs, Peter; Cole, Colin; Stichel, Sebastian; Berg, Mats; Manfred, Plöchl

    2017-08-01

    The main task for heavy haul railway operators is to reduce the cost of exported minerals and enhance the long-term viability of rail transport operations through increasing productivity by running longer and heavier trains. The common opinion is that this is achievable by means of implementation of high adhesion locomotives with advanced AC traction technologies. Modern AC high adhesion locomotives are very complex mechatronic systems and can be designed with two alternative traction topologies of either bogie or individual axle controls. This paper describes a modelling approach for these two types of AC traction systems with the application of an advanced co-simulation methodology, where an electrical system and a traction algorithm are modelled in Matlab/Simulink, and a mechanical system is modelled in a multibody software package. Although the paper concentrates on the analysis of the functioning for these two types of traction control systems, the choice of reference slip values also has an influence on the performance of both systems. All these design variations and issues have been simulated for various adhesion conditions at the wheel-rail interface and their influence on the high traction performance of a locomotive equipped with two three-axle bogies has been discussed.

  9. Development of an attention-touch control for manual cervical distraction: a pilot randomized clinical trial for patients with neck pain.

    PubMed

    Gudavalli, M Ram; Salsbury, Stacie A; Vining, Robert D; Long, Cynthia R; Corber, Lance; Patwardhan, Avinash G; Goertz, Christine M

    2015-06-05

    Manual cervical distraction (MCD) is a traction-based therapy performed with a manual contact over the cervical region producing repeating cycles while patients lie prone. This study evaluated a traction force-based minimal intervention for use as an attention-touch control in clinical trials of MCD for patients with chronic neck pain. We conducted a mixed-methods, pilot randomized clinical trial in adults with chronic neck pain. Participants were allocated to three traction force ranges of MCD: low force/minimal intervention (0-20 N), medium force (21-50 N), or high force (51-100 N). Clinicians delivered five treatments over two weeks consisting of three sets of five cycles of MCD at the C5 vertebra and occiput. Traction forces were measured at each treatment. Patient-reported outcomes included a pain visual analogue scale (VAS), Neck Disability Index (NDI), Credibility and Expectancy Questionnaire (CEQ), and adverse effects. A qualitative interview evaluated treatment group allocation perceptions. We randomized 48 participants, allocating an average of five each month. Forty-five participants completed the trial with three participants lost to follow-up. Most participants were women (65%) and white (92%) with a mean (SD) age of 46.8 (12.5) years. Mean traction force values were within the prescribed force ranges for each group at the C5 and occiput levels. Neck pain VAS demonstrated a benefit for high traction force MCD compared to the low force group [adjusted mean difference 15.6; 95% confidence interval (CI) 1.6 to 29.7]. Participants in the medium traction force group demonstrated improvements in NDI compared to the low force group (adjusted mean difference 3.0; 95% CI 0.1 to 5.9), as did participants in the high traction force group (adjusted mean difference 2.7; 95% CI -0.1 to 5.6). CEQ favored the high force group. Most low force participants correctly identified their treatment allocation in the qualitative interview. No serious adverse events were

  10. Intravenous flurbiprofen axetil can stabilize the hemodynamic instability due to mesenteric traction syndrome--evaluation with continuous measurement of the systemic vascular resistance index using a FloTrac® sensor.

    PubMed

    Takada, Motoshi; Taruishi, Chieko; Sudani, Tomoko; Suzuki, Akira; Iida, Hiroki

    2013-08-01

    Evaluation of the stabilizing effect of intravenous flurbiprofen axetil against hemodynamic instability due to mesenteric traction syndrome (MTS) by continuous measurement of systemic vascular resistance index (SVRI) using a FloTrac(®) sensor was evaluated. Prospective randomized trial. A single-center study performed in an educational hospital. Two prospective studies were carried out, each with 40 patients scheduled for elective open abdominal surgery. Twenty patients received 50 mg of flurbiprofen axetil after the recognition of MTS by the anesthesiologist (group FT). The remaining patients served as controls (groups CP and CT). SVRI data was collected every 20 seconds for 1 hour after starting the laparotomy. The average SVRI prior to skin incision was taken as the baseline. Following 3 values were devised to evaluate MTS: the S-value (sum total of changes in SVRI from baseline), the T-value (period during which SVRI remained 20% or more below baseline), and the M-value (maximum change in SVRI from baseline). In group FP, decrease in SVRI was smaller than in group CP, and statistical differences in the 3 values were found. In group FT, SVRI recovered earlier than in group CT, and statistical differences were found in S-value and T-value. However, the M-value had no statistical differences. Intravenous flurbiprofen axetil can stabilize the hemodynamic instability due to MTS. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Integrated IR sensors

    NASA Astrophysics Data System (ADS)

    Tom, Michael; Trujillo, Edward

    1994-06-01

    Integrated infrared (IR) sensors which exploit modular avionics concepts can provide features such as operational flexibility, enhanced stealthiness, and ease of maintenance to meet the demands of tactical, airborne sensor systems. On-board, tactical airborne sensor systems perform target acquisition, tracking, identification, threat warning, missile launch detection, and ground mapping in support of situation awareness, self-defense, navigation, target attack, weapon support, and reconnaissance activities. The use of sensor suites for future tactical aircraft such as US Air Force's multirole fighter require a blend of sensor inputs and outputs that may vary over time. It is expected that special-role units of these tactical aircraft will be formed to conduct tasks and missions such as anti-shipping, reconnaissance, or suppression of enemy air defenses.

  12. Open abdomen with vacuum-assisted wound closure and mesh-mediated fascial traction in patients with complicated diffuse secondary peritonitis: A single-center 8-year experience.

    PubMed

    Tolonen, Matti; Mentula, Panu; Sallinen, Ville; Rasilainen, Suvi; Bäcklund, Minna; Leppäniemi, Ari

    2017-06-01

    Open abdomen (OA) treatment in patients with peritonitis is increasing worldwide. Various temporary abdominal closure devices are being used. This study included patients with complicated diffuse secondary peritonitis, OA, and vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM). The aim of this study was to describe mortality and major morbidity in terms of delayed primary fascial closure and enteroatmospheric fistula rates. This was a single-academic-center retrospective study of consecutive patients with diffuse peritonitis, OA, and VAWCM between years 2008 and 2016. Descriptive and univariate analyses were performed. Forty-one patients were identified and analyzed. Median age was 59 years, preoperative septic shock was diagnosed in 54% (n = 22), and 59% (n = 24) had a postoperative peritonitis. Mortality was 29% (n = 12), and 76% (n = 31) of patients were admitted in the intensive care unit. The median duration of OA was 7 days with a median of two dressing changes. Delayed primary fascial closure rate among survivors was 92% (n = 33), and enteroatmospheric fistulas developed in 7% (n = 3). In a subgroup analysis, patients with OA in the primary laparotomy for peritonitis (n = 27) were compared with patients with OA in the subsequent laparotomies (n = 14). There were no significant differences between groups. The VAWCM technique in patients with complicated secondary diffuse peritonitis and OA yields excellent results in terms of delayed primary fascial closure rate and a low number of enteroatmospheric fistulas. It seems to be safe to close the abdomen at the index laparotomy, if possible, even if there is a risk of a need of OA later. Therapeutic/care management study, level IV.

  13. Ultrasound Effect in the Removal of Intraradicular Posts Cemented with Different Materials.

    PubMed

    Berbert, Fabio Luiz Camargo Vilella; Espir, Camila Galletti; Crisci, Fernando Simões; Ferrarezz, Marcelo; de Andrade, T; Chávez-Andrade, Gisselle Moraima; Leonardo, Renato de Toledo; Saad, José Roberto Cury; Segalla, José Claudio Martins; Vaz, Luiz Geraldo; Jordão Basso, Keren Cristina Fagundes; Dantas, Andrea Abi Rached

    2015-06-01

    This study evaluated the effect of ultrasonic vibration on the tensile strength required to remove intraradicular post cemented with different materials. Bovine teeth were selected, and 7 mm of the cervical root canals were prepared to size 5 Largo drill, the posts were cemented with zinc phosphate, Enforce (resin) or Rely X (glass ionomer). The specimens were divided into six groups (n = 10), according to the following procedures: GI-cementation with zinc phosphate associated with traction force; GII-cementation with zinc phosphate associated with ultrasonic activation and traction force; G111-cementation with Enforce associated with traction force; GIV-cementation with Enforce associated with ultrasonic activation and traction force; GV-cementation with Rely X associated with traction force; and GVI-cementation with Rely X associated with ultrasonic activation and traction force. The tensile test was conducted using the electromechanical testing machine, the force was determined by a specialized computer program and ultrasonic activation using the Jet Sonic Four Plus (Gnatus) device in 10P. Concerning to average ranking, GI showed statistically significant difference in comparison with GII and GVI (p < 0.05); there was no statistical difference in GIII and GIV when compared to other groups (p > 0.05). The ultrasound favored the intraradicular post traction regardless of the employed cement in greater or lesser extent. The post removal is a routine practice in the dental office, therefore, new solutions and better alternatives are need to the practitioner. We did not find in the literature many articles referring to this practice. Thus, the results from this study are relevant in the case planning and to promote more treatment options.

  14. The Use of Superselective Arteriography in the Evaluation of the Influence of Intracapsular Hip Joint Pressure on the Blood Flow of the Femoral Head.

    PubMed

    Wu, Kai; Huang, Jianhua; Wang, Qiugen

    2016-01-01

    We aimed to analyze the intracapsular pressure of the hip joint following femoral neck fracture and its relationship to the position of the hip or to traction and (using superselective arteriography) to evaluate the blood supply to the femoral head and the influence of traction and hip position on the blood supply. Twenty-six cases of fresh Garden type I-III femoral neck fractures were enrolled. After being placed in the neutral position, in internal rotation or with traction of 3 and 5 kg, respectively, intracapsular manometric changes were measured. Eight cases underwent superselective arteriography of the medial circumflex femoral artery and its branches under the manometric changes of the hip joint capsule. Twenty-four to 48 h after the injury, the intracapsular pressure was significantly higher on the fractured side than on the normal side. The mean pressure was 28.41 ± 9.339 mm Hg in fully extended hips in the neutral position, 79.92 ± 12.80 mm Hg in internally rotated hips, 51.39 ± 15.41 mm Hg in hips with 3 kg of traction and 64.81 ± 13.56 mm Hg in hips with 5 kg of traction. The arteriographic findings revealed that traction and internal rotation reduced the perfusion of the femoral head at the medial circumflex femoral artery and its branches, and also negatively influenced venous reflux. Traction and internal rotation both caused the intracapsular pressure of the hip joint to rise considerably, which reduced the femoral head perfusion and impeded venous reflux. This could lead to avascular necrosis of the femoral head. © 2015 S. Karger AG, Basel.

  15. IMAGING AND MEASUREMENT OF THE PRERETINAL SPACE IN VITREOMACULAR ADHESION AND VITREOMACULAR TRACTION BY A NEW SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY ANALYSIS.

    PubMed

    Stopa, Marcin; Marciniak, Elżbieta; Rakowicz, Piotr; Stankiewicz, Agnieszka; Marciniak, Tomasz; Dąbrowski, Adam

    2017-10-01

    To evaluate a new method for volumetric imaging of the preretinal space (also known as the subhyaloid, subcortical, or retrocortical space) and investigate differences in preretinal space volume in vitreomacular adhesion (VMA) and vitreomacular traction (VMT). Nine patients with VMA and 13 with VMT were prospectively evaluated. Automatic inner limiting membrane line segmentation, which exploits graph search theory implementation, and posterior cortical vitreous line segmentation were performed on 141 horizontal spectral domain optical coherence tomography B-scans per patient. Vertical distances (depths) between the posterior cortical vitreous and inner limiting membrane lines were calculated for each optical coherence tomography B-scan acquired. The derived distances were merged and visualized as a color depth map that represented the preretinal space between the posterior surface of the hyaloid and the anterior surface of the retina. The early treatment d retinopathy study macular map was overlaid onto final virtual maps, and preretinal space volumes were calculated for each early treatment diabetic retinopathy study map sector. Volumetric maps representing preretinal space volumes were created for each patient in the VMA and VMT groups. Preretinal space volumes were larger in all early treatment diabetic retinopathy study map macular regions in the VMT group compared with those in the VMA group. The differences reached statistical significance in all early treatment diabetic retinopathy study sectors, except for the superior outer macula and temporal outer macula where significance values were P = 0.05 and P = 0.08, respectively. Overall, the relative differences in preretinal space volumes between the VMT and VMA groups varied from 2.7 to 4.3 in inner regions and 1.8 to 2.9 in outer regions. Our study provides evidence of significant differences in preretinal space volume between eyes with VMA and those with VMT. This may be useful not only in the investigation

  16. Winter Weather Checklists

    MedlinePlus

    ... walkways Supply of cat litter or bag of sand to add traction on walkways Flashlight and extra ... sealant for emergency tire repair Road salt and sand to help tires get traction Booster cables Emergency ...

  17. Posterior Cervical Transfacet Fusion with Facetal Spacer for the Treatment of Single-Level Cervical Radiculopathy: A Randomized, Controlled Prospective Study.

    PubMed

    Lenzi, Jacopo; Nardone, Antonio; Passacantilli, Emiliano; Caporlingua, Alessandro; Lapadula, Gennaro; Caporlingua, Federico

    2017-04-01

    Single-level cervical radiculopathy may be treated conservatively with cervical tractions. Posterior cervical transfacet fusion with a facetal spacer is a viable option. The aim of the present study is to compare posterior cervical transfacet fusion with conservative physical treatment in single-level cervical radiculopathy. A total of 80 patients were randomized in 2 groups, a surgical group in which patients were given posterior cervical transfacet fusion and a traction group in which patients were treated conservatively with mechanical cervical tractions. Visual analog scale for arm and neck, Neck Disability Index, and Short Form-36 (SF-36) questionnaires were administered preoperatively and after treatment up to 12 months. After treatment, visual analog scale arm scores were greater in traction group (4.7 vs. 1.5 the day after treatment) and at follow-up controls (traction group vs. surgical group: 5.3 vs. 0.6 at 1 month, 3.6 vs. 0.3 at 6 months, 1.8 vs. 0.2 at 12 months). Neck Disability Index scores were lower in the surgical group (surgical group vs. traction group: 4.4 vs. 20.3 at 1 month, 1.3 vs. 10.5 at 6 months). SF-36 scores were greater in the surgical group (surgical group vs. traction group: 96 vs. 70 at 1 month, 96.5 vs. 82.6 at 6 months). Neck disability index and SF-36 scores were superimposable between the groups at 12-month follow-up. No adjacent-segment arthrosis or late complications were reported at 1-year follow-up in the surgical group. posterior cervical transfacet fusion is a safe and effective procedure to treat single-level cervical radiculopathy. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. THE TEMPLATE FOR THE ACQUISITION OF THE NEXT MULTINATIONAL MULTI-ROLE FIGHTER

    DTIC Science & Technology

    2015-10-01

    creation of this unique teaming arrangement. Therefore, the conclusion of this report is that when each of the six individual countries purchased their...States in purchasing the F-16. 13 Figure 2: MNFP F-16 during MLU test and evaluation. 14 Because of the immediate successes to the program... bribes . In the end, this agreement was considered the ‘Deal of the Century’, not only for the benefits provided to participating militaries but also

  19. Ammunition Suite for the FCS Multi-role Armament and Ammunition System (MRAAS)

    DTIC Science & Technology

    2001-06-20

    Cards Large Scale Gap Test (LSGT) Exploding Foil Initiator ( EFI ) Effort 19 Slow Burning Layer Fast Burning Layer FASTCORE Nitramines ETPEs RDX CL20...Center Burst Charge 48 M80 Grenades With Center Burst Charge ü Trade off performance with size, weight, etc. ü Develop initial space claim for...submunition ü Dynamic Analysis of projectile for different submunitions MRAAS Trades underway • Accomplishments – Initial meetings with TRADOC, Ft Knox and Ft

  20. Two-staged Correction of Severe Congenital Scoliosis Associated With Intraspinal Abnormalities.

    PubMed

    Zhang, Zhenxing; Hui, Hua; Liu, Tuanjiang; Zhang, Zhenping; Hao, Dingjun

    2016-10-01

    A retrospective study. To analyze the efficacy and safety of perioperative halo-gravity traction as an adjunct to posterior vertebral column resection (PVCR) in the treatment of patients with severe congenital scoliosis and coexisting asymptomatic intraspinal pathologies (diastematomyelia and/or tethered cord). Few reports to our knowledge review the use of perioperative halo-gravity traction and PVCR in this patient population. A total of 17 patients with a minimum 2-year follow-up who underwent PVCR using perioperative halo-gravity traction were analyzed. Patients were analyzed by age at date of examination (range, 11-23 y; mean, 14.4 y), sex (7 male, 10 female), major coronal curve magnitude (range, 108-149 degrees; average, 125 degrees), major sagittal curve magnitude (range, 72-118 degrees; average, 91 degrees). Complications related to halo traction and PVCR were reviewed. Radiographic outcomes demonstrated Cobb angle of major curve had an average correction of 28% after halo traction and it measured 53 degrees (range, 42-84 degrees) at the last follow-up, for a 58% correction. Maximal kyphosis improved to 58 degrees (range, 43-76 degrees) at ultimate follow-up. There were no permanent neurological deficits in this series. The study results suggested that surgical treatment for intraspinal abnormality may be unnecessary in asymptomatic patients with severe congenital scoliosis who are undergoing scoliosis corrective surgery. PVCR combined with perioperative traction is a safe and effective alternative for such patients.

  1. An Efficient Implementation of the GMC Micromechanics Model for Multi-Phased Materials with Complex Microstructures

    NASA Technical Reports Server (NTRS)

    Pindera, Marek-Jerzy; Bednarcyk, Brett A.

    1997-01-01

    An efficient implementation of the generalized method of cells micromechanics model is presented that allows analysis of periodic unidirectional composites characterized by repeating unit cells containing thousands of subcells. The original formulation, given in terms of Hill's strain concentration matrices that relate average subcell strains to the macroscopic strains, is reformulated in terms of the interfacial subcell tractions as the basic unknowns. This is accomplished by expressing the displacement continuity equations in terms of the stresses and then imposing the traction continuity conditions directly. The result is a mixed formulation wherein the unknown interfacial subcell traction components are related to the macroscopic strain components. Because the stress field throughout the repeating unit cell is piece-wise uniform, the imposition of traction continuity conditions directly in the displacement continuity equations, expressed in terms of stresses, substantially reduces the number of unknown subcell traction (and stress) components, and thus the size of the system of equations that must be solved. Further reduction in the size of the system of continuity equations is obtained by separating the normal and shear traction equations in those instances where the individual subcells are, at most, orthotropic. The reformulated version facilitates detailed analysis of the impact of the fiber cross-section geometry and arrangement on the response of multi-phased unidirectional composites with and without evolving damage. Comparison of execution times obtained with the original and reformulated versions of the generalized method of cells demonstrates the new version's efficiency.

  2. Determination of the thermal stress wave propagation in orthotropic hollow cylinder based on classical theory of thermoelasticity

    NASA Astrophysics Data System (ADS)

    Shahani, Amir Reza; Sharifi Torki, Hamid

    2018-01-01

    The thermoelasticity problem in a thick-walled orthotropic hollow cylinder is solved analytically using finite Hankel transform and Laplace transform. Time-dependent thermal and mechanical boundary conditions are applied on the inner and the outer surfaces of the cylinder. For solving the energy equation, the temperature itself is considered as boundary condition to be applied on both the inner and the outer surfaces of the orthotropic cylinder. Two different cases are assumed for solving the equation of motion: traction-traction problem (tractions are prescribed on both the inner and the outer surfaces) and traction-displacement (traction is prescribed on the inner surface and displacement is prescribed on the outer surface of the hollow orthotropic cylinder). Due to considering uncoupled theory, after obtaining temperature distribution, the dynamical structural problem is solved and closed-form relations are derived for radial displacement, radial and hoop stress. As a case study, exponentially decaying temperature with respect to time is prescribed on the inner surface of the cylinder and the temperature of the outer surface is considered to be zero. Owing to solving dynamical problem, the stress wave propagation and its reflections were observed after plotting the results in both cases.

  3. Study of dynamic emission spectra from lubricant films in an elastohydrodynamic contact using Fourier transform spectroscopy

    NASA Technical Reports Server (NTRS)

    Lauer, J. L.

    1978-01-01

    Infrared emission spectra were obtained through a diamond window from lubricating fluids in an operating sliding elastohydrodynamic contact and analyzed by comparison with static absorption spectra under similar pressures. Different loads, shear rates and temperatures were used. Most of the spectra exhibited polarization characteristics, indicating directional alignment of the lubricant in the EHD contact. Among the fluids studied were a "traction" fluid, an advanced ester, and their mixtures, a synthetic paraffin, a naphthenic reference fluid (N-1), both neat and containing 1 percent of p-tricresyl phosphate as an anti-wear additive, and a C-ether. Traction properties were found to be nearly proportional to mixture composition for traction fluid and ester mixtures. The anti-wear additive reduced traction and fluid temperature under low loads but increased them under higher loads, giving rise to formation of a friction polymer.

  4. Direct hip joint distraction during acetabular fracture surgery using the AO universal manipulator.

    PubMed

    Calafi, L Afshin; Routt, M L Chip

    2010-02-01

    Certain acetabular fractures may necessitate distraction of the hip joint for removal of intra-articular debris and assessment of reduction. Distraction can be accomplished by manual traction, using a traction table or an AO universal manipulator (UM). The UM is a relatively simple and an inexpensive device that can provide focal distraction in a controlled manner without the risks associated with the use of a traction table. We describe a technique using the UM for hip joint distraction during acetabular fracture surgery through a Kocher-Langenbeck surgical exposure.

  5. Large-Scale V/STOL Experimental Investigations of an Ejector-Lift Fighter and a Twin Tilt-Nacelle Transport

    NASA Technical Reports Server (NTRS)

    Dudley, Michael R.

    2016-01-01

    In the 1980s NASA Aeronautics was actively involved in full-scale wind tunnel testing of promising VSTOL aircraft concepts. This presentation looks at two, a multi-role fighter and a subsonic tactical transport. Their strengths and weaknesses are discussed with some of the rationale that ultimately led to the selection of competing concepts for production, namely the V-22 Osprey and the F-35 Lightning. The E7-A STOVL multi-role fighter was the product of an aircraft development program in the late 1980s by NASA, the Defense Advanced Research Projects Agency (DARPA), the Canadian Department of Industry Science and Technology (DIST), and industry partners General Dynamics and Boeing Dehavilland. The program was conducted an in response to increasing US-UK interest in supersonic STOVL fighters. The objective was to design an aircraft that could replace most existing close air support-air combat fighters with a single aircraft that had some of the qualities of an air superiority fighter and the deployment flexibility of a VSTOL aircraft. The resulting E7-A concept was a delta-wing supersonic fighter that used a fuselage-mounted thrust augmenting ejector and a ventral deflecting jet nozzle for vertical lift. The Grumman Aircraft Company, the Navy, and NASA developed the Design-698 (D-698) subsonic tactical transport in response to the Navy's Type A VSTOL utility aircraft requirement. The objective was to develop a subsonic utility transport with the operational flexibility of a helicopter, but with greater speed and range. The D-698 employs two high-bypass turbofan engines mounted on a dumbbell that rotates through ninety degrees for vertical takeoff and cruise flight. Movable vanes positioned in the exhaust flow provide control in hover with the need for reaction control jets. The presentations concluding comments suggest that technology advances in the last thirty-years may justify the value of revisiting some of these concepts.

  6. Force sensing using 3D displacement measurements in linear elastic bodies

    NASA Astrophysics Data System (ADS)

    Feng, Xinzeng; Hui, Chung-Yuen

    2016-07-01

    In cell traction microscopy, the mechanical forces exerted by a cell on its environment is usually determined from experimentally measured displacement by solving an inverse problem in elasticity. In this paper, an innovative numerical method is proposed which finds the "optimal" traction to the inverse problem. When sufficient regularization is applied, we demonstrate that the proposed method significantly improves the widely used approach using Green's functions. Motivated by real cell experiments, the equilibrium condition of a slowly migrating cell is imposed as a set of equality constraints on the unknown traction. Our validation benchmarks demonstrate that the numeric solution to the constrained inverse problem well recovers the actual traction when the optimal regularization parameter is used. The proposed method can thus be applied to study general force sensing problems, which utilize displacement measurements to sense inaccessible forces in linear elastic bodies with a priori constraints.

  7. System for controlling a hybrid energy system

    DOEpatents

    Hoff, Brian D.; Akasam, Sivaprasad

    2013-01-29

    A method includes identifying a first operating sequence of a repeated operation of at least one non-traction load. The method also includes determining first and second parameters respectively indicative of a requested energy and output energy of the at least one non-traction load and comparing the determined first and second parameters at a plurality of time increments of the first operating sequence. The method also includes determining a third parameter of the hybrid energy system indicative of energy regenerated from the at least one non-traction load and monitoring the third parameter at the plurality of time increments of the first operating sequence. The method also includes determining at least one of an energy deficiency or an energy surplus associated with the non-traction load of the hybrid energy system and selectively adjusting energy stored within the storage device during at least a portion of a second operating sequence.

  8. Cell prestress. II. Contribution of microtubules

    NASA Technical Reports Server (NTRS)

    Stamenovic, Dimitrije; Mijailovich, Srboljub M.; Tolic-Norrelykke, Iva Marija; Chen, Jianxin; Wang, Ning; Ingber, D. E. (Principal Investigator)

    2002-01-01

    The tensegrity model hypothesizes that cytoskeleton-based microtubules (MTs) carry compression as they balance a portion of cell contractile stress. To test this hypothesis, we used traction force microscopy to measure traction at the interface of adhering human airway smooth muscle cells and a flexible polyacrylamide gel substrate. The prediction is that if MTs balance a portion of contractile stress, then, upon their disruption, the portion of stress balanced by MTs would shift to the substrate, thereby causing an increase in traction. Measurements were done first in maximally activated cells (10 microM histamine) and then again after MTs had been disrupted (1 microM colchicine). We found that after disruption of MTs, traction increased on average by approximately 13%. Because in activated cells colchicine induced neither an increase in intracellular Ca(2+) nor an increase in myosin light chain phosphorylation as shown previously, we concluded that the observed increase in traction was a result of load shift from MTs to the substrate. In addition, energy stored in the flexible substrate was calculated as work done by traction on the deformation of the substrate. This result was then utilized in an energetic analysis. We assumed that cytoskeleton-based MTs are slender elastic rods supported laterally by intermediate filaments and that MTs buckle as the cell contracts. Using the post-buckling equilibrium theory of Euler struts, we found that energy stored during buckling of MTs was quantitatively consistent with the measured increase in substrate energy after disruption of MTs. This is further evidence supporting the idea that MTs are intracellular compression-bearing elements.

  9. Earthquake fracture energy inferred from kinematic rupture models on extended faults

    USGS Publications Warehouse

    Tinti, E.; Spudich, P.; Cocco, M.

    2005-01-01

    We estimate fracture energy on extended faults for several recent earthquakes by retrieving dynamic traction evolution at each point on the fault plane from slip history imaged by inverting ground motion waveforms. We define the breakdown work (Wb) as the excess of work over some minimum traction level achieved during slip. Wb is equivalent to "seismological" fracture energy (G) in previous investigations. Our numerical approach uses slip velocity as a boundary condition on the fault. We employ a three-dimensional finite difference algorithm to compute the dynamic traction evolution in the time domain during the earthquake rupture. We estimate Wb by calculating the scalar product between dynamic traction and slip velocity vectors. This approach does not require specifying a constitutive law and assuming dynamic traction to be collinear with slip velocity. If these vectors are not collinear, the inferred breakdown work depends on the initial traction level. We show that breakdown work depends on the square of slip. The spatial distribution of breakdown work in a single earthquake is strongly correlated with the slip distribution. Breakdown work density and its integral over the fault, breakdown energy, scale with seismic moment according to a power law (with exponent 0.59 and 1.18, respectively). Our estimates of breakdown work range between 4 ?? 105 and 2 ?? 107 J/m2 for earthquakes having moment magnitudes between 5.6 and 7.2. We also compare our inferred values with geologic surface energies. This comparison might suggest that breakdown work for large earthquakes goes primarily into heat production. Copyright 2005 by the American Geophysical Union.

  10. Review of factors affecting aircraft wet runway performance

    NASA Technical Reports Server (NTRS)

    Yager, T. J.

    1983-01-01

    Problems associated with aircraft operations on wet runways are discussed and major factors which influence tire/runway braking and cornering traction capability are identified including runway characteristics, tire hydroplaning, brake system anomalies, and pilot inputs. Research results from investigations conducted at the Langley Aircraft Landing Loads and Traction Facility and from tests with instrumented ground vehicles and aircraft are summarized to indicate the effects of different aircraft, tire, and runway parameters. Several promising means are described for improving tire/runway water drainage capability, brake system efficiency, and pilot training to help optimize aircraft traction performance on wet runways.

  11. Force generation by groups of migrating bacteria

    PubMed Central

    Koch, Matthias D.; Liu, Guannan; Stone, Howard A.; Shaevitz, Joshua W.

    2017-01-01

    From colony formation in bacteria to wound healing and embryonic development in multicellular organisms, groups of living cells must often move collectively. Although considerable study has probed the biophysical mechanisms of how eukaryotic cells generate forces during migration, little such study has been devoted to bacteria, in particular with regard to the question of how bacteria generate and coordinate forces during collective motion. This question is addressed here using traction force microscopy. We study two distinct motility mechanisms of Myxococcus xanthus, namely, twitching and gliding. For twitching, powered by type-IV pilus retraction, we find that individual cells exert local traction in small hotspots with forces on the order of 50 pN. Twitching bacterial groups also produce traction hotspots, but with forces around 100 pN that fluctuate rapidly on timescales of <1.5 min. Gliding, the second motility mechanism, is driven by lateral transport of substrate adhesions. When cells are isolated, gliding produces low average traction on the order of 1 Pa. However, traction is amplified approximately fivefold in groups. Advancing protrusions of gliding cells push, on average, in the direction of motion. Together, these results show that the forces generated during twitching and gliding have complementary characters, and both forces have higher values when cells are in groups. PMID:28655845

  12. Force generation by groups of migrating bacteria.

    PubMed

    Sabass, Benedikt; Koch, Matthias D; Liu, Guannan; Stone, Howard A; Shaevitz, Joshua W

    2017-07-11

    From colony formation in bacteria to wound healing and embryonic development in multicellular organisms, groups of living cells must often move collectively. Although considerable study has probed the biophysical mechanisms of how eukaryotic cells generate forces during migration, little such study has been devoted to bacteria, in particular with regard to the question of how bacteria generate and coordinate forces during collective motion. This question is addressed here using traction force microscopy. We study two distinct motility mechanisms of Myxococcus xanthus , namely, twitching and gliding. For twitching, powered by type-IV pilus retraction, we find that individual cells exert local traction in small hotspots with forces on the order of 50 pN. Twitching bacterial groups also produce traction hotspots, but with forces around 100 pN that fluctuate rapidly on timescales of <1.5 min. Gliding, the second motility mechanism, is driven by lateral transport of substrate adhesions. When cells are isolated, gliding produces low average traction on the order of 1 Pa. However, traction is amplified approximately fivefold in groups. Advancing protrusions of gliding cells push, on average, in the direction of motion. Together, these results show that the forces generated during twitching and gliding have complementary characters, and both forces have higher values when cells are in groups.

  13. Solid lubrication design methodology, phase 2

    NASA Technical Reports Server (NTRS)

    Pallini, R. A.; Wedeven, L. D.; Ragen, M. A.; Aggarwal, B. B.

    1986-01-01

    The high temperature performance of solid lubricated rolling elements was conducted with a specially designed traction (friction) test apparatus. Graphite lubricants containing three additives (silver, phosphate glass, and zinc orthophosphate) were evaluated from room temperature to 540 C. Two hard coats were also evaluated. The evaluation of these lubricants, using a burnishing method of application, shows a reasonable transfer of lubricant and wear protection for short duration testing except in the 200 C temperature range. The graphite lubricants containing silver and zinc orthophosphate additives were more effective than the phosphate glass material over the test conditions examined. Traction coefficients ranged from a low of 0.07 to a high of 0.6. By curve fitting the traction data, empirical equations for slope and maximum traction coefficient as a function of contact pressure (P), rolling speed (U), and temperature (T) can be developed for each lubricant. A solid lubricant traction model was incorporated into an advanced bearing analysis code (SHABERTH). For comparison purposes, preliminary heat generation calculations were made for both oil and solid lubricated bearing operation. A preliminary analysis indicated a significantly higher heat generation for a solid lubricated ball bearing in a deep groove configuration. An analysis of a cylindrical roller bearing configuration showed a potential for a low friction solid lubricated bearing.

  14. High mobility vehicle

    NASA Technical Reports Server (NTRS)

    Wilcox, Brian H. (Inventor); Nasif, Annette K. (Inventor)

    2001-01-01

    A vehicle, for driving over a ground surface, has a body with a left side, a right side, a front and a back. The vehicle includes left and right drive mechanisms. Each mechanism includes first and second traction elements for engaging the ground surface and transmitting a driving force between the vehicle and ground surface. Each mechanism includes first and second arms coupled to the first and second traction elements for relative rotation about first and second axis respectively. Each mechanism includes a rotor having a third axis, the rotor coupled to the body for rotation about the third axis and coupled to the first and second arms for relative rotation about the third axis. The mechanism includes first and second drive motors for driving the first and second traction elements and first and second transmissions, driven by the first and second motors and engaging the rotor. Driving the first and second traction elements simultaneously rotates the rotor relative to the first and second arms, respectively.

  15. Force transmission in migrating cells

    PubMed Central

    Sauser, Roger; Ambrosi, Davide; Meister, Jean-Jacques; Verkhovsky, Alexander B.

    2010-01-01

    During cell migration, forces generated by the actin cytoskeleton are transmitted through adhesion complexes to the substrate. To investigate the mechanism of force generation and transmission, we analyzed the relationship between actin network velocity and traction forces at the substrate in a model system of persistently migrating fish epidermal keratocytes. Front and lateral sides of the cell exhibited much stronger coupling between actin motion and traction forces than the trailing cell body. Further analysis of the traction–velocity relationship suggested that the force transmission mechanisms were different in different cell regions: at the front, traction was generated by a gripping of the actin network to the substrate, whereas at the sides and back, it was produced by the network’s slipping over the substrate. Treatment with inhibitors of the actin–myosin system demonstrated that the cell body translocation could be powered by either of the two different processes, actomyosin contraction or actin assembly, with the former associated with significantly larger traction forces than the latter. PMID:20100912

  16. Designing and Managing Successful International Joint Development Programs

    DTIC Science & Technology

    2016-04-30

    Åèìáëáíáçå=oÉëÉ~êÅÜ=mêçÖê~ã= dê~Çì~íÉ=pÅÜççä=çÑ=_ìëáåÉëë=C=mìÄäáÅ=mçäáÅó= k~î~ä=mçëíÖê~Çì~íÉ=pÅÜççä= SYM-AM- 16 -070 mêçÅÉÉÇáåÖë= çÑ=íÜÉ...acquisition issues. He derives knowledge from complex data collections via succinct and innovative tables, charts, and maps . His recent research...attack aircraft and the Air Force’s F- 16 Fighting Falcon multirole fighter. Two years later, an advanced short takeoff and vertical landing (ASTOVL

  17. A Process to Establish the Common Functions Performed by a Multi-Role Vessel

    DTIC Science & Technology

    2010-09-01

    25 5.9 EPF – Environmental Protection Functions...Functions WFO Offshore Warfighting Functions EPF Environmental Protection Functions EPF .1 Waste Treatment Functions DSTO-TR-2473 16 HSF...Mission Command Function CFV Vessel Command Function EPF Environmental Protection Functions HSF Hotel Services Functions HVAC HVAC Functions

  18. Mechanics of advancing pin-loaded contacts with friction

    NASA Astrophysics Data System (ADS)

    Sundaram, Narayan; Farris, T. N.

    2010-11-01

    This paper considers finite friction contact problems involving an elastic pin and an infinite elastic plate with a circular hole. Using a suitable class of Green's functions, the singular integral equations governing a very general class of conforming contact problems are formulated. In particular, remote plate stresses, pin loads, moments and distributed loading of the pin by conservative body forces are considered. Numerical solutions are presented for different partial slip load cases. In monotonic loading, the dependence of the tractions on the coefficient of friction is strongest when the contact is highly conforming. For less conforming contacts, the tractions are insensitive to an increase in the value of the friction coefficient above a certain threshold. The contact size and peak pressure in monotonic loading are only weakly dependent on the pin load distribution, with center loads leading to slightly higher peak pressure and lower peak shear than distributed loads. In contrast to half-plane cylinder fretting contacts, fretting behavior is quite different depending on whether or not the pin is allowed to rotate freely. If pin rotation is disallowed, the fretting tractions resemble half-plane fretting tractions in the weakly conforming regime but the contact resists sliding in the strongly conforming regime. If pin rotation is allowed, the shear traction behavior resembles planar rolling contacts in that one slip zone is dominant and the peak shear occurs at its edge. In this case, the effects of material dissimilarity in the strongly conforming regime are only secondary and the contact never goes into sliding. Fretting tractions in the forward and reversed load states show shape asymmetry, which persists with continued load cycling. Finally, the governing integro-differential equation for full sliding is derived; in the limiting case of no friction, the same equation governs contacts with center loading and uniform body force loading, resulting in

  19. Substrate Deformation Predicts Neuronal Growth Cone Advance

    PubMed Central

    Athamneh, Ahmad I.M.; Cartagena-Rivera, Alexander X.; Raman, Arvind; Suter, Daniel M.

    2015-01-01

    Although pulling forces have been observed in axonal growth for several decades, their underlying mechanisms, absolute magnitudes, and exact roles are not well understood. In this study, using two different experimental approaches, we quantified retrograde traction force in Aplysia californica neuronal growth cones as they develop over time in response to a new adhesion substrate. In the first approach, we developed a novel method, to our knowledge, for measuring traction forces using an atomic force microscope (AFM) with a cantilever that was modified with an Aplysia cell adhesion molecule (apCAM)-coated microbead. In the second approach, we used force-calibrated glass microneedles coated with apCAM ligands to guide growth cone advance. The traction force exerted by the growth cone was measured by monitoring the microneedle deflection using an optical microscope. Both approaches showed that Aplysia growth cones can develop traction forces in the 100–102 nN range during adhesion-mediated advance. Moreover, our results suggest that the level of traction force is directly correlated to the stiffness of the microneedle, which is consistent with a reinforcement mechanism previously observed in other cell types. Interestingly, the absolute level of traction force did not correlate with growth cone advance toward the adhesion site, but the amount of microneedle deflection did. In cases of adhesion-mediated growth cone advance, the mean needle deflection was 1.05 ± 0.07 μm. By contrast, the mean deflection was significantly lower (0.48 ± 0.06 μm) when the growth cones did not advance. Our data support a hypothesis that adhesion complexes, which can undergo micron-scale elastic deformation, regulate the coupling between the retrogradely flowing actin cytoskeleton and apCAM substrates, stimulating growth cone advance if sufficiently abundant. PMID:26445437

  20. [Comparison of dressings and devices to secure peripheral venous catheters in the emergency department: suitability according to patient profile].

    PubMed

    Moreno Martín, Montserrat; Villamor Ordozgoiti, Alberto; Gutiérrez Martín, Montserrat; Santiago Bosch, Mercedes; Grau Ferrer, Helena; Gamero Saavedra, Tamara

    2016-10-01

    To identify the most suitably designed dressings and devices to secure peripheral venous catheters (PVCs) in different types of patients. To evaluate the traction force the dressings could withstand and times they are able to keep the PVC in place in the emergency department. Quasi-experimental descriptive observational study with inferential statistics to compare variables. We studied the designs of devices and dressings for securing PVCs in the emergency department (Omnifix, Tegaderm, Oper Dres, Steri-strip, and stopcocks) and special adaptations devised by the authors: A (Tegaderm), A1 (Tegaderm + Steristrip), A2 (Tegaderm + Oper Dres), B (Omnifix), C (Omnifix doubled). Participants carried out 520 tests on models of human patients to simulate standard, hairy, and hairy-sweaty skin. Costs were as follows: A, € 0.15; A1, € 0.35; A2, € 0.18; B, € 0.005; C, € 0.01. The times in seconds required to apply the dressings were as follows: (A, 15; A1, 25; A2, 20; B, 20; C, 35). The dressings withstood the following traction forces in grams: lengthwise, A, 760; B, 1694; C, 1530); perpendicular (A, 785; B, 1450; C, 3290), and transversal (A, 760; A1, 1220; A2, 1510; B, 1720; C, 2255). Design C was able to withstand greater forces in the traction tests. Extra surgical tape significantly improved resistance to traction when a stopcock was used. Using a Steri-strip with the Tegaderm device increased resistance to traction, although the improvement was less than that obtained with the Omnifix. The Tegaderm plus Omnifix design was significantly more resistant to traction than the Tegaderm by itself at only a slightly higher cost; the combination design, therefore, may be more recommendable. However, our results for resistance, cost, and application time showed that the Omnifix (desing B) is the best choice for securing a PVC.

  1. An in vitro correlation of mechanical forces and metastatic capacity

    NASA Astrophysics Data System (ADS)

    Indra, Indrajyoti; Undyala, Vishnu; Kandow, Casey; Thirumurthi, Umadevi; Dembo, Micah; Beningo, Karen A.

    2011-02-01

    Mechanical forces have a major influence on cell migration and are predicted to significantly impact cancer metastasis, yet this idea is currently poorly defined. In this study we have asked if changes in traction stress and migratory properties correlate with the metastatic progression of tumor cells. For this purpose, four murine breast cancer cell lines derived from the same primary tumor, but possessing increasing metastatic capacity, were tested for adhesion strength, traction stress, focal adhesion organization and for differential migration rates in two-dimensional and three-dimensional environments. Using traction force microscopy (TFM), we were surprised to find an inverse relationship between traction stress and metastatic capacity, such that force production decreased as the metastatic capacity increased. Consistent with this observation, adhesion strength exhibited an identical profile to the traction data. A count of adhesions indicated a general reduction in the number as metastatic capacity increased but no difference in the maturation as determined by the ratio of nascent to mature adhesions. These changes correlated well with a reduction in active beta-1 integrin with increasing metastatic ability. Finally, in two dimensions, wound healing, migration and persistence were relatively low in the entire panel, maintaining a downward trend with increasing metastatic capacity. Why metastatic cells would migrate so poorly prompted us to ask if the loss of adhesive parameters in the most metastatic cells indicated a switch to a less adhesive mode of migration that would only be detected in a three-dimensional environment. Indeed, in three-dimensional migration assays, the most metastatic cells now showed the greatest linear speed. We conclude that traction stress, adhesion strength and rate of migration do indeed change as tumor cells progress in metastatic capacity and do so in a dimension-sensitive manner.

  2. Design Thinking: A Methodology towards Sustainable Problem Solving in Higher Education in South Africa

    ERIC Educational Resources Information Center

    Munyai, Keneilwe

    2016-01-01

    This short paper explores the potential contribution of design thinking methodology to the education and training system in South Africa. Design thinking is slowly gaining traction in South Africa. Design Thinking is gaining traction in South Africa. There is offered by the Hasso Plattner Institute of Design Thinking at the University of Cape Town…

  3. A combined dislocation fan-finite element (DF-FE) method for stress field simulation of dislocations emerging at the free surfaces of 3D elastically anisotropic crystals

    NASA Astrophysics Data System (ADS)

    Balusu, K.; Huang, H.

    2017-04-01

    A combined dislocation fan-finite element (DF-FE) method is presented for efficient and accurate simulation of dislocation nodal forces in 3D elastically anisotropic crystals with dislocations intersecting the free surfaces. The finite domain problem is decomposed into half-spaces with singular traction stresses, an infinite domain, and a finite domain with non-singular traction stresses. As such, the singular and non-singular parts of the traction stresses are addressed separately; the dislocation fan (DF) method is introduced to balance the singular traction stresses in the half-spaces while the finite element method (FEM) is employed to enforce the non-singular boundary conditions. The accuracy and efficiency of the DF method is demonstrated using a simple isotropic test case, by comparing it with the analytical solution as well as the FEM solution. The DF-FE method is subsequently used for calculating the dislocation nodal forces in a finite elastically anisotropic crystal, which produces dislocation nodal forces that converge rapidly with increasing mesh resolutions. In comparison, the FEM solution fails to converge, especially for nodes closer to the surfaces.

  4. A Sticky Situation.

    PubMed

    Weng, Christina Y; Khimani, Karima S; Foroozan, Rod; Gospe, Sidney M; Bhatti, M Tariq

    2018-04-26

    An 81-year-old man with bilateral progressively blurry vision and optic disc swelling was referred for evaluation. Examination and ancillary testing confirmed a diagnosis of bilateral vitreopapillary traction (VPT) accompanied by unilateral tractional retinoschisis in the right eye. Pars plana vitrectomy was performed to release the traction in both eyes. Visual acuity improved in the right eye and stabilized in the left eye. Retinoschisis in the right eye resolved. The visual field improved in both eyes, although the left eye demonstrated a persistent hemifield defect likely attributable to a prior optic neuropathy. Distinguishing VPT optic neuropathy (VPTON) from nonarteritic anterior ischemic optic neuropathy (NAION) is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. A Hypothesis: Could Portable Natural Grass be a Risk Factor for Knee Injuries?

    PubMed Central

    Orchard, John; Rodas, Gil; Til, Lluis; ArdevÒl, Jordi; Chivers, Ian

    2008-01-01

    Previous study has shown a likely link between increased shoe- surface traction and risk of knee Anterior Cruciate Ligament (ACL) injury. Portable natural grass systems are being used more often in sport, but no study to date has investigated their relative safety. By their nature, they must have high resistance to falling apart and therefore newly laid systems may be at risk of creating excessive shoe-surface traction. This study describes two clusters of knee injuries (particularly non-contact ACL injuries), each occurring to players of one professional football team at single venue, using portable grass, in a short space of time. The first series included two ACL injuries, one posterolateral complex disruption and one lateral ligament tear occurring in two rugby league games on a portable bermudagrass surface in Brisbane, Australia. The second series included four non-contact ACL injuries over a period of ten weeks in professional soccer games on a portable Kentucky bluegrass/perennial ryegrass surface in Barcelona, Spain. Possible intrinsic risk factors are discussed but there was no common risk shared by the players. Although no measures of traction were made at the Brisbane venue, average rotational traction was measured towards the end of the injury cluster at Camp Nou, Barcelona, to be 48 Nm. Chance undoubtedly had a part to play in these clusters, but the only obvious common risk factor was play on a portable natural grass surface soon after it was laid. Further study is required to determine whether portable natural grass systems may exhibit high shoe-surface traction soon after being laid and whether this could be a risk factor for knee injury. Key pointsExcessive shoe-surface traction is a hypothesised risk factor for knee ligament injuries, including anterior cruciate ligament injuries.Portable natural grass systems (by their nature in order to prevent grass rolls or squares from falling apart) will tend to exhibit high resistance to tearing when first

  6. Gas cooled traction drive inverter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chinthavali, Madhu Sudhan

    The present invention provides a modular circuit card configuration for distributing heat among a plurality of circuit cards. Each circuit card includes a housing adapted to dissipate heat in response to gas flow over the housing. In one aspect, a gas-cooled inverter includes a plurality of inverter circuit cards, and a plurality of circuit card housings, each of which encloses one of the plurality of inverter cards.

  7. Traction Aid for Wheeled Vehicles

    DTIC Science & Technology

    1975-07-01

    driver’s position in the load vehicle to assist him in applying constant braking loads, 4) a drum and line fifth wheel sys- tem attached to the load...in Alaskan snow, and the results were so encouraging that further testing of the device was requested. In comparison to tire chains, the Tyr-Trac...vehicle with the end of the line anchored and the speed of the line played off the drum measuring the actual vehicle speed. An eight channel

  8. Gas cooled traction drive inverter

    DOEpatents

    Chinthavali, Madhu Sudhan

    2013-10-08

    The present invention provides a modular circuit card configuration for distributing heat among a plurality of circuit cards. Each circuit card includes a housing adapted to dissipate heat in response to gas flow over the housing. In one aspect, a gas-cooled inverter includes a plurality of inverter circuit cards, and a plurality of circuit card housings, each of which encloses one of the plurality of inverter cards.

  9. Wet runways. [aircraft landing and directional control

    NASA Technical Reports Server (NTRS)

    Horne, W. B.

    1975-01-01

    Aircraft stopping and directional control performance on wet runways is discussed. The major elements affecting tire/ground traction developed by jet transport aircraft are identified and described in terms of atmospheric, pavement, tire, aircraft system and pilot performance factors or parameters. Research results are summarized, and means for improving or restoring tire traction/aircraft performance on wet runways are discussed.

  10. Design of a vehicle based system to prevent ozone loss

    NASA Technical Reports Server (NTRS)

    Lynn, Sean R.; Bunker, Deborah; Hesbach, Thomas D., Jr.; Howerton, Everett B.; Hreinsson, G.; Mistr, E. Kirk; Palmer, Matthew E.; Rogers, Claiborne; Tischler, Dayna S.; Wrona, Daniel J.

    1993-01-01

    Reduced quantities of ozone in the atmosphere allow greater levels of ultraviolet light (UV) radiation to reach the earth's surface. This is known to cause skin cancer and mutations. Chlorine liberated from Chlorofluorocarbons (CFC's) and natural sources initiate the destruction of stratospheric ozone through a free radical chain reaction. The project goals are to understand the processes which contribute to stratospheric ozone loss, examine ways to prevent ozone loss, and design a vehicle-based system to carry out the prevention scheme. The 1992/1993 design objectives were to accomplish the first two goals and define the requirements for an implementation vehicle to be designed in detail starting next year. Many different ozone intervention schemes have been proposed though few have been researched and none have been tested. A scheme proposed by R.J. Cicerone, Scott Elliot and R.P.Turco late in 1991 was selected because of its research support and economic feasibility. This scheme uses hydrocarbon injected into the Antarctic ozone hole to form stable compounds with free chlorine, thus reducing ozone depletion. Because most polar ozone depletion takes place during a 3-4 week period each year, the hydrocarbon must be injected during this time window. A study of the hydrocarbon injection requirements determined that 100 aircraft traveling Mach 2.4 at a maximum altitude of 66,000 ft. would provide the most economic approach to preventing ozone loss. Each aircraft would require an 8,000 nm. range and be able to carry 35,000 lbs. of propane. The propane would be stored in a three-tank high pressure system. Missions would be based from airport regions located in South America and Australia. To best provide the requirements of mission analysis, an aircraft with L/D(sub cruise) = 10.5, SFC = 0.65 (the faculty advisor suggested that this number is too low) and a 250,000 lb TOGW was selected as a baseline. Modularity and multi-role functionality were selected to be key

  11. Locating helicopter emergency medical service bases to optimise population coverage versus average response time.

    PubMed

    Garner, Alan A; van den Berg, Pieter L

    2017-10-16

    New South Wales (NSW), Australia has a network of multirole retrieval physician staffed helicopter emergency medical services (HEMS) with seven bases servicing a jurisdiction with population concentrated along the eastern seaboard. The aim of this study was to estimate optimal HEMS base locations within NSW using advanced mathematical modelling techniques. We used high resolution census population data for NSW from 2011 which divides the state into areas containing 200-800 people. Optimal HEMS base locations were estimated using the maximal covering location problem facility location optimization model and the average response time model, exploring the number of bases needed to cover various fractions of the population for a 45 min response time threshold or minimizing the overall average response time to all persons, both in green field scenarios and conditioning on the current base structure. We also developed a hybrid mathematical model where average response time was optimised based on minimum population coverage thresholds. Seven bases could cover 98% of the population within 45mins when optimised for coverage or reach the entire population of the state within an average of 21mins if optimised for response time. Given the existing bases, adding two bases could either increase the 45 min coverage from 91% to 97% or decrease the average response time from 21mins to 19mins. Adding a single specialist prehospital rapid response HEMS to the area of greatest population concentration decreased the average state wide response time by 4mins. The optimum seven base hybrid model that was able to cover 97.75% of the population within 45mins, and all of the population in an average response time of 18 mins included the rapid response HEMS model. HEMS base locations can be optimised based on either percentage of the population covered, or average response time to the entire population. We have also demonstrated a hybrid technique that optimizes response time for a given

  12. Investigation into the impact of agility on conceptual fighter design

    NASA Technical Reports Server (NTRS)

    Engelbeck, R. M.

    1995-01-01

    The Agility Design Study was performed by the Boeing Defense and Space Group for the NASA Langley Research Center. The objective of the study was to assess the impact of agility requirements on new fighter configurations. Global trade issues investigated were the level of agility, the mission role of the aircraft (air-to-ground, multi-role, or air-to-air), and whether the customer is Air force, Navy, or joint service. Mission profiles and design objectives were supplied by NASA. An extensive technology assessment was conducted to establish the available technologies to industry for the aircraft. Conceptual level methodology is presented to assess the five NASA-supplied agility metrics. Twelve configurations were developed to address the global trade issues. Three-view drawings, inboard profiles, and performance estimates were made and are included in the report. A critical assessment and lessons learned from the study are also presented.

  13. The nucleus is an intracellular propagator of tensile forces in NIH 3T3 fibroblasts

    PubMed Central

    Alam, Samer G.; Lovett, David; Kim, Dae In; Roux, Kyle J.; Dickinson, Richard B.; Lele, Tanmay P.

    2015-01-01

    ABSTRACT Nuclear positioning is a crucial cell function, but how a migrating cell positions its nucleus is not understood. Using traction-force microscopy, we found that the position of the nucleus in migrating fibroblasts closely coincided with the center point of the traction-force balance, called the point of maximum tension (PMT). Positioning of the nucleus close to the PMT required nucleus–cytoskeleton connections through linker of nucleoskeleton-to-cytoskeleton (LINC) complexes. Although the nucleus briefly lagged behind the PMT following spontaneous detachment of the uropod during migration, the nucleus quickly repositioned to the PMT within a few minutes. Moreover, traction-generating spontaneous protrusions deformed the nearby nucleus surface to pull the nuclear centroid toward the new PMT, and subsequent retraction of these protrusions relaxed the nuclear deformation and restored the nucleus to its original position. We propose that the protruding or retracting cell boundary transmits a force to the surface of the nucleus through the intervening cytoskeletal network connected by the LINC complexes, and that these forces help to position the nucleus centrally and allow the nucleus to efficiently propagate traction forces across the length of the cell during migration. PMID:25908852

  14. Prospective study of nerve injuries associated with hip arthroscopy in the lateral position using the modified portals

    PubMed Central

    Salas, Antonio Porthos; O’Donnell, John M.

    2016-01-01

    To access the central compartment of the hip, distraction is essential in hip arthroscopy (HA); nerve injuries have long been accepted as a complication of this surgical procedure, with an incidence ranging from 0 to 46%. Only one previous article collected data prospectively, and the authors utilized a supine technique, with a modified mid-anterior portal. Our study also used prospectively collected data, from a group of 200 consecutive patients who had HA performed in the lateral position using the paratrochanteric portals. Our results were that four patients (2%) reported symptoms of neurological deficits after surgery, three patients with traction times ranging from 20 to 41 min, their neurological deficits resolved completely over a time from 6 to 9 weeks. The fourth patient who had the longest traction time of 73 min, and also greater than usual traction, his neurological deficit resolved at 12 weeks. Our hypothesis of 200 hip arthroscopies, performed in the lateral position by the modified paratrochanteric portals, the incidence of nerve injuries would be lower than 46%. We found an incidence of 2%, all affecting the perineum and genitals and all occurring in men, no differences between the age, surgery side or type of surgery performed on the patient were found to have statistical differences. Traction times with <31.5 min were related with fewer incidences of neurological symptoms. On the basis of this study, all patients with traction times below 73 min can be confidently reassured that any deficit will recover within 3 months. PMID:29632688

  15. Hip arthroscopy. The lateral approach.

    PubMed

    Glick, J M

    2001-10-01

    The lateral approach provides an easy and safe access to the hip joint. The line from skin to the joint itself is a straight, downward drop (Fig. 18). The vital arteries and nerves are a safe distance from the portal sites. The potential problems that can arise from this procedure are from the traction applying a compression force on the branches of the pudendal nerve as they cross the ischium (Fig. 19) and traction force on the sciatic nerve. I have always maintained that traction should be treated like a tourniquet; that is, it should be applied for no more then 2 hours. [figure: see text] Furthermore, the amount of traction should not exceed 75 pounds. I use a tensiometer, but it is not mandatory because the major issue with traction is the duration of application. I have monitored the sciatic nerve using both evoke potentials and, in some cases, motor potentials in over 50 cases in the past year, and the poundage and time limits of the traction (75 pounds and 2 hours) were verified. In addition, if the fracture [figure: see text] table has a vertical post as well as a peroneal post, set the vertical post in the back of the patient, and not in the front. Flexing the hip around that post will greatly increase the traction and at the same time will place an extreme stretch on the sciatic nerve, setting up the chance of a significant sciatic nerve neuropraxia. To protect the pudendal nerve, Lyon et al suggest that the perineal post be at least 9 cm in diameter to distribute the forces in a wide area on the ischium and make sure that the pelvis is well supported so the pressure of the post is not placed directly on the this nerve. The perineal posts on most fracture tables are only 3 cm in diameter. These can be made larger by wrapping them with padding. In some fracture tables, the slats that support the lower leg can be removed, and consequently the support on the pelvis is lost. For hip arthroscopy, the slats do not have to be removed. The lateral approach

  16. Study on launch scheme of space-net capturing system.

    PubMed

    Gao, Qingyu; Zhang, Qingbin; Feng, Zhiwei; Tang, Qiangang

    2017-01-01

    With the continuous progress in active debris-removal technology, scientists are increasingly concerned about the concept of space-net capturing system. The space-net capturing system is a long-range-launch flexible capture system, which has great potential to capture non-cooperative targets such as inactive satellites and upper stages. In this work, the launch scheme is studied by experiment and simulation, including two-step ejection and multi-point-traction analyses. The numerical model of the tether/net is based on finite element method and is verified by full-scale ground experiment. The results of the ground experiment and numerical simulation show that the two-step ejection and six-point traction scheme of the space-net system is superior to the traditional one-step ejection and four-point traction launch scheme.

  17. Study on launch scheme of space-net capturing system

    PubMed Central

    Zhang, Qingbin; Feng, Zhiwei; Tang, Qiangang

    2017-01-01

    With the continuous progress in active debris-removal technology, scientists are increasingly concerned about the concept of space-net capturing system. The space-net capturing system is a long-range-launch flexible capture system, which has great potential to capture non-cooperative targets such as inactive satellites and upper stages. In this work, the launch scheme is studied by experiment and simulation, including two-step ejection and multi-point-traction analyses. The numerical model of the tether/net is based on finite element method and is verified by full-scale ground experiment. The results of the ground experiment and numerical simulation show that the two-step ejection and six-point traction scheme of the space-net system is superior to the traditional one-step ejection and four-point traction launch scheme. PMID:28877187

  18. Development of ATC for High Speed and High Density Commuter Line

    NASA Astrophysics Data System (ADS)

    Okutani, Tamio; Nakamura, Nobuyuki; Araki, Hisato; Irie, Shouji; Osa, Hiroki; Sano, Minoru; Ikeda, Keigo; Ozawa, Hiroyuki

    A new ATC (Automatic Train Control) system has been developed with solutions to realize short train headway by assured braking utilizing digital data transmission via rails; the digital data for the ATP (Automatic Train Protection) function; and to achieve EMC features for both AC and DC sections. The DC section is of the unprecedented DC traction power supply system utilizing IGBT PWM converter at all DC substations. Within the AC section, train traction force is controlled by PWM converter/inverters. The carrier frequencies of the digital data signals and chopping frequency of PWM traction power converters on-board are decided via spectral analysis of noise up to degraded mode cases of equipment. Developed system was equipped to the Tukuba Express Line, new commuter line of Tokyo metropolitan area, and opened since Aug. 2005.

  19. NASA Tech Briefs, May 2012

    NASA Technical Reports Server (NTRS)

    2012-01-01

    and Control; Long-Life, Lightweight, Multi-Roller Traction Drives for Planetary Vehicle Surface Exploration; Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications; Electrochemical Ultracapacitors Using Graphitic Nanostacks; Improved Whole-Blood-Staining Device; Monitoring Location and Angular Orientation of a Pill; Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity; Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars; High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle; PRTs and Their Bonding for Long-Duration, Extreme-Temperature Environments; Mid- and Long-IR Broadband Quantum Well Photodetector; 3D Display Using Conjugated Multiband Bandpass Filters; Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow; Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators; Dual-Compartment Inflatable Suitlock; Large-Strain Transparent Magnetoactive Polymer Nanocomposites; Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine; Time Distribution Using SpaceWire in the SCaN Testbed on ISS; and Techniques for Solution- Assisted Optical Contacting.

  20. MV-22: A Hybrid, Multi-Role Aircraft for the Complex Battlefields of the Future

    DTIC Science & Technology

    2010-04-05

    ofTerrorism: What does it all mean ? (lecture, Marine Corps Command and Staff College, Quantico, VA, February 23, 201 0). 41 Sanders, http... does it all mean ? Lecture, Marine Corps Command and StaffCollege, Quantico, VA, February 23, 2010. Mullins, Mark. "U.S. Navy Irregular Warfare Office...Second Nicaraguan Campaign, 1927-33." Aerospace Power Journal XV, 3 (Fall2001). 33 Johnson, Wray R. "Counterinsurgency in a Time of Terrorism: What

  1. Arthroscopic Preparation 0f the Posterior and Posteroinferior Glenoid Labrum

    DTIC Science & Technology

    2007-11-01

    cient traction to easily visual - ize and work in this area of the joint (Figure I). Glenohumeml arthroscopy is initiated from a standard posterior...flexion, and 10 Ibs of traction. the diagnostic glenohumeral arthroscopy is completed, a mid-glenoid (anteroinferior) portal is made just...lorrhaphy. Arthroscopy . 2006; 22:1138 el-5. Section Editor: Steven F. Harwin, MD NOVEMBER 2007 I Volume 30 • Number 11 3. Difelice GS , Williams RJ lil

  2. Calcium oscillations in wounded fibroblast monolayers are spatially regulated through substrate mechanics

    NASA Astrophysics Data System (ADS)

    Lembong, Josephine; Sabass, Benedikt; Stone, Howard A.

    2017-08-01

    The maintenance of tissue integrity is essential for the life of multicellular organisms. Healing of a skin wound is a paradigm for how various cell types localize and repair tissue perturbations in an orchestrated fashion. To investigate biophysical mechanisms associated with wound localization, we focus on a model system consisting of a fibroblast monolayer on an elastic substrate. We find that the creation of an edge in the monolayer causes cytosolic calcium oscillations throughout the monolayer. The oscillation frequency increases with cell density, which shows that wound-induced calcium oscillations occur collectively. Inhibition of myosin II reduces the number of oscillating cells, demonstrating a coupling between actomyosin activity and calcium response. The spatial distribution of oscillating cells depends on the stiffness of the substrate. For soft substrates with a Young’s modulus E ~ 360 Pa, oscillations occur on average within 0.2 mm distance from the wound edge. Increasing substrate stiffness leads to an average localization of oscillations away from the edge (up to ~0.6 mm). In addition, we use traction force microscopy to determine stresses between cells and substrate. We find that an increase of substrate rigidity leads to a higher traction magnitude. For E  <  ~2 kPa, the traction magnitude is strongly concentrated at the monolayer edge, while for E  >  ~8 kPa, traction magnitude is on average almost uniform beneath the monolayer. Thus, the spatial occurrence of calcium oscillations correlates with the cell-substrate traction. Overall, the experiments with fibroblasts demonstrate a collective, chemomechanical localization mechanism at the edge of a wound with a potential physiological role.

  3. Analysis of the monitoring data of geomagnetic storm interference in the electrification system of a high-speed railway

    NASA Astrophysics Data System (ADS)

    Liu, Lianguang; Ge, Xiaoning; Zong, Wei; Zhou, You; Liu, Mingguang

    2016-10-01

    To study the impact of geomagnetic storm on the equipment of traction electrification system in the high-speed railway, geomagnetically induced current (GIC) monitoring devices were installed in the Hebi East traction power supply substation of the Beijing-Hong Kong Dedicated Passenger Line in January 2015, and GICs were captured during the two geomagnetic storms on 17 March and 23 June 2015. In order to investigate the GIC flow path, both in the track circuit and in the traction network adopting the autotransformer feeding system, a GIC monitor plan was proposed for the electrical system in the Hebi East traction power supply substation. This paper analyzes the correlation between the GIC captured on 17 March and the geomagnetic data obtained from the Malingshan Geomagnetic Observatory and presents a regression analysis between the measured GIC and the calculated geoelectric fields on 23 June in the high-speed railway. The maximum GICs measured in the track circuit are 1.08 A and 1.74 A during the two geomagnetic storms. We find that it is necessary to pay attention on the throttle transformers and track circuits, as the most sensitive elements responding to the extreme geomagnetic storms in the high-speed railway.

  4. The Diagnostic Value of the Vacuum Phenomenon during Hip Arthroscopy

    PubMed Central

    Rath, Ehud; Gortzak, Yair; Schwarzkopf, Ran; Benkovich, Vadim; Cohen, Eugene; Atar, Dan

    2011-01-01

    The diagnostic value of the vacuum phenomenon between the femoral head and the acetabulum, and time frame of its occurrence after application of traction is an important clinical question. The resulting arthrogram may outline the shape, location, and extent of cartilage lesions prior to arthroscopy of the hip joint. The presence, duration, and diagnostic information of the vacuum phenomenon were evaluated in 24 hips that underwent arthroscopy. The operative diagnosis was compared to the results of imaging studies and to findings obtained during a traction trial prior to arthroscopy. Indications for arthroscopy included avascular necrosis, labral tears, loose bodies, osteoarthrosis, and intractable hip pain. In 22 hips the vacuum phenomenon developed within 30 seconds after application of traction. The most important data obtained from the vacuum phenomenon was the location and extent of femoral head articular cartilage detachment and the presence of nonossified loose bodies. The vacuum phenomenon did not reveal labral or acetabular cartilage pathology in any of these patients. The vacuum phenomenon obtained during the trial of traction can add valuable information prior to hip arthroscopy. Femoral head articular cartilage detachment was best documented by this method. The hip arthroscopist should utilize this diagnostic window routinely prior to hip arthroscopy. PMID:24977068

  5. New methods of magnet-based instrumentation for NOTES.

    PubMed

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  6. The Diagnostic Value of the Vacuum Phenomenon during Hip Arthroscopy.

    PubMed

    Rath, Ehud; Gortzak, Yair; Schwarzkopf, Ran; Benkovich, Vadim; Cohen, Eugene; Atar, Dan

    2011-01-01

    The diagnostic value of the vacuum phenomenon between the femoral head and the acetabulum, and time frame of its occurrence after application of traction is an important clinical question. The resulting arthrogram may outline the shape, location, and extent of cartilage lesions prior to arthroscopy of the hip joint. The presence, duration, and diagnostic information of the vacuum phenomenon were evaluated in 24 hips that underwent arthroscopy. The operative diagnosis was compared to the results of imaging studies and to findings obtained during a traction trial prior to arthroscopy. Indications for arthroscopy included avascular necrosis, labral tears, loose bodies, osteoarthrosis, and intractable hip pain. In 22 hips the vacuum phenomenon developed within 30 seconds after application of traction. The most important data obtained from the vacuum phenomenon was the location and extent of femoral head articular cartilage detachment and the presence of nonossified loose bodies. The vacuum phenomenon did not reveal labral or acetabular cartilage pathology in any of these patients. The vacuum phenomenon obtained during the trial of traction can add valuable information prior to hip arthroscopy. Femoral head articular cartilage detachment was best documented by this method. The hip arthroscopist should utilize this diagnostic window routinely prior to hip arthroscopy.

  7. The Rapid Transit System That Achieves Higher Performance with Lower Life-Cycle Costs

    NASA Astrophysics Data System (ADS)

    Sone, Satoru; Takagi, Ryo

    In the age of traction system made of inverter and ac traction motors, distributed traction system with pure electric brake of regenerative mode has been recognised very advantageous. This paper proposes a new system as the lowest life-cycle cost system for high performance rapid transit, a new architecture and optimum parameters of power feeding system, and a new running method of trains. In Japan, these components of this proposal, i.e. pure electric brake and various countermeasures of reducing loss of regeneration have been already popular but not as yet the new running method for better utilisation of the equipment and for lower life-cycle cost. One example of what are proposed in this paper will be made as Tsukuba Express, which is under construction as the most modern commuter railway in Greater Tokyo area.

  8. Investigation on cause of the elevator turbine wear

    NASA Astrophysics Data System (ADS)

    Zhang, J.; Ouyang, W. P.; Xue, J. A.

    2018-03-01

    Elevator traction turbine is often worn for various reasons, causing serious safety hazard. It is explained the main causes of traction wheel wear in detail in combination with a large number of engineering experience. The effect of turbine wear on the actual operation of the elevator is verified by contrast experiment, which is helpful to identify risks early. It is put forward on some reasonable suggestions for elevator inspection, maintenance and management.

  9. Development of a Drilling Fluid Drive Downhole Tractor in Oil Field

    NASA Astrophysics Data System (ADS)

    Fang, Delei; Shang, Jianzhong; Liu, Yiying; Wu, Wei; Luo, Zirong

    2018-01-01

    This paper proposes a drilling fluid drive downhole tractor, which has the advantages of compact structure, large traction, fast speed and high reliability. The overall mechanical structure of the tractor is introduced, the concrete structures including supporting structure and cushion mechanism are designed. And its all-hydraulic drive continuous propulsion principle is analyzed. Finally the simulation analysis of the tractor operation is carried out to prove that the traction motion scheme is feasible.

  10. Inclusion of service robots in the daily lives of frail older users: A step-by-step definition procedure on users' requirements.

    PubMed

    García-Soler, Álvaro; Facal, David; Díaz-Orueta, Unai; Pigini, Lucia; Blasi, Lorenzo; Qiu, Renxi

    2018-01-01

    The implications for the inclusion of robots in the daily lives of frail older adults, especially in relation to these population needs, have not been extensively studied. The "Multi-Role Shadow Robotic System for Independent Living" (SRS) project has developed a remotely-controlled, semi-autonomous robotic system to be used in domestic environments. The objective of this paper is to document the iterative procedure used to identify, select and prioritize user requirements. Seventy-four requirements were identified by means of focus groups, individual interviews and scenario-based interviews. The list of user requirements, ordered according to impact, number and transnational criteria, revealed a high number of requirements related to basic and instrumental activities of daily living, cognitive and social support and monitorization, and also involving privacy, safety and adaptation issues. Analysing and understanding older users' perceptions and needs when interacting with technological devices adds value to assistive technology and ensures that the systems address currently unmet needs. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Developing UGVs for the FCS program

    NASA Astrophysics Data System (ADS)

    Kamsickas, Gary M.; Ward, John N.

    2003-09-01

    The FCS Operational Requirements Document (ORD) identifies unmanned systems as a key component of the FCS Unit of Action. FCS unmanned systems include Unmanned Aerial Vehicles (UAV), Unmanned Ground Vehicles (UGV), Unattended Ground Sensors (UGS) and Unattended Munitions (UM). Unmanned systems are intended to enhance the Unit of Action across the full range of operations when integrated with manned platforms. Unmanned systems will provide the commander with tools to gather battlespace information while significantly reducing overall soldier risk. Unmanned systems will be used in some cases to augment or replace human intervention to perform many of the dirty, dull and dangerous missions presently performed by soldiers and to serve as a combat multiplier for mission performance, force protection and survivability. This paper focuses on the application of UGVs within the FCS Unit of Action. There are three different UGVs planned to support the FCS Unit of Action; the Soldier Unmanned Ground Vehicle (SUGV); The Multi-role Utility Logistics Equipment (MULE) platform; and the Armed Robotic Vehicle (ARV).

  12. Experimental investigation of a 0.15 scale model of a conformal variable-ramp inlet for the F-16 airplane

    NASA Technical Reports Server (NTRS)

    Hawkins, J. E.

    1980-01-01

    A 0.15 scale model of a proposed conformal variable-ramp inlet for the Multirole Fighter was tested from Mach 0.8 to 2.2 at a wide range of angles of attack and sideslip. Inlet ramp angle was varied to optimize ramp angle as a function of engine airflow, Mach number, angle of attack, and angle of sideslip. Several inlet configuration options were investigated to study their effects on inlet operation and to establish the final flight configuration. These variations were cowl sidewall cutback, cowl lip bluntness, boundary layer bleed, and first-ramp leading edge shape. Diagnostic and engine face instrumentation were used to evaluate inlet operation at various inlet stations and at the inlet/engine interface. Pressure recovery and stability of the inlet were satisfactory for the proposed application. On the basis of an engine stability audit of the worst-case instantaneous distortion patterns, no inlet/engine compatibility problems are expected for normal operations.

  13. F-22 cockpit avionics: a systems integration success story

    NASA Astrophysics Data System (ADS)

    Greeley, Kevin W.; Schwartz, Richard J.

    2000-08-01

    The F-22 'Raptor' is being developed and manufactured as multi-role fighter aircraft for the 'air dominance' mission. The F-22 team is led by Lockheed Martin, with Boeing and Pratt & Whitney as partners. The F-22 weapons system combines supersonic cruise, maneuverability, stealth, and an extensive suite of tightly integrated sensors to achieve a high level of lethality and invulnerability against current and projected threat systems such as fighter aircraft and surface to air missiles. Despite high automation of the complex systems installed in the F-22, the pilot is heavily tasked for air battle management. Response timelines are compressed due to supersonic cruise velocities. These factors challenge the Pilot Vehicle Interface (PVI) design. This paper discusses the team's response to these challenges, describing the physical cockpit layout, its controls and displays, and the hardware architecture, software tools, and development process used to mature the F-22 'Raptor' weapons system, including a review of Human Factors design considerations for F-22 displays.

  14. Systems level test and simulation for photonic processing systems

    NASA Astrophysics Data System (ADS)

    Erteza, I. A.; Stalker, K. T.

    1995-08-01

    Photonic technology is growing in importance throughout DOD. Programs have been underway in each of the Services to demonstrate the ability of photonics to enhance current electronic performance in several prototype systems, such as the Navy's SLQ-32 radar warning receiver, the Army's multi-role survivable radar and the phased array radar controller for the Airborne Warning and Control System (AWACS) upgrade. Little, though, is known about radiation effects; the component studies do not furnish the information needed to predict overall system performance in a radiation environment. To date, no comprehensive test and analysis program has been conducted to evaluate sensitivity of overall system performance to the radiation environment. The goal of this program is to relate component level effects to system level performance through modeling and testing of a selected optical processing system, and to help direct component testing to items which can directly and adversely affect overall system performance. This report gives a broad overview of the project, highlighting key results.

  15. Quadrotor Control in the Presence of Unknown Mass Properties

    NASA Astrophysics Data System (ADS)

    Duivenvoorden, Rikky Ricardo Petrus Rufino

    Quadrotor UAVs are popular due to their mechanical simplicity, as well as their capability to hover and vertically take-off and land. As applications diversify, quadrotors are increasingly required to operate under unknown mass properties, for example as a multirole sensor platform or for package delivery operations. The work presented here consists of the derivation of a generalized quadrotor dynamic model without the typical simplifying assumptions on the first and second moments of mass. The maximum payload capacity of a quadrotor in hover, and the observability of the unknown mass properties are discussed. A brief introduction of L1 adaptive control is provided, and three different L 1 adaptive controllers were designed for the Parrot AR.Drone quadrotor. Their tracking and disturbance rejection performance was compared to the baseline nonlinear controller in experiments. Finally, the results of the combination of L1 adaptive control with iterative learning control are presented, showing high performance trajectory tracking under uncertainty.

  16. Digital control of highly augmented combat rotorcraft

    NASA Technical Reports Server (NTRS)

    Tischler, Mark B.

    1987-01-01

    Proposed concepts for the next generation of combat helicopters are to be embodied in a complex, highly maneuverable, multiroled vehicle with avionics systems. Single pilot and nap-of-the-Earth operations require handling qualities which minimize the involvement of the pilot in basic stabilization tasks. To meet these requirements will demand a full authority, high-gain, multimode, multiply-redundant, digital flight-control system. The gap between these requirements and current low-authority, low-bandwidth operational rotorcraft flight-control technology is considerable. This research aims at smoothing the transition between current technology and advanced concept requirements. The state of the art of high-bandwidth digital flight-control systems are reviewed; areas of specific concern for flight-control systems of modern combat are exposed; and the important concepts are illustrated in design and analysis of high-gain, digital systems with a detailed case study involving a current rotorcraft system. Approximate and exact methods are explained and illustrated for treating the important concerns which are unique to digital systems.

  17. Finite element analysis of weightbath hydrotraction treatment of degenerated lumbar spine segments in elastic phase.

    PubMed

    Kurutz, M; Oroszváry, L

    2010-02-10

    3D finite element models of human lumbar functional spinal units (FSU) were used for numerical analysis of weightbath hydrotraction therapy (WHT) applied for treating degenerative diseases of the lumbar spine. Five grades of age-related degeneration were modeled by material properties. Tensile material parameters of discs were obtained by parameter identification based on in vivo measured elongations of lumbar segments during regular WHT, compressive material constants were obtained from the literature. It has been proved numerically that young adults of 40-45 years have the most deformable and vulnerable discs, while the stability of segments increases with further aging. The reasons were found by analyzing the separated contrasting effects of decreasing incompressibility and increasing hardening of nucleus, yielding non-monotonous functions of stresses and deformations in terms of aging and degeneration. WHT consists of indirect and direct traction phases. Discs show a bilinear material behaviour with higher resistance in indirect and smaller in direct traction phase. Consequently, although the direct traction load is only 6% of the indirect one, direct traction deformations are 15-90% of the indirect ones, depending on the grade of degeneration. Moreover, the ratio of direct stress relaxation remains equally about 6-8% only. Consequently, direct traction controlled by extra lead weights influences mostly the deformations being responsible for the nerve release; while the stress relaxation is influenced mainly by the indirect traction load coming from the removal of the compressive body weight and muscle forces in the water. A mildly degenerated disc in WHT shows 0.15mm direct, 0.45mm indirect and 0.6mm total extension; 0.2mm direct, 0.6mm indirect and 0.8mm total posterior contraction. A severely degenerated disc exhibits 0.05mm direct, 0.05mm indirect and 0.1mm total extension; 0.05mm direct, 0.25mm indirect and 0.3mm total posterior contraction. These

  18. Shear rheological characterization of motor oils

    NASA Technical Reports Server (NTRS)

    Bair, Scott; Winer, Ward O.

    1988-01-01

    Measurements of high pressure viscosity, traction coefficient, and EHD film thickness were performed on twelve commercial automotive engine oils, a reference oil, two unformulated base oils and two unformated base oil and polymer blends. An effective high shear rate inlet viscosity was calculated from film thickness and pressure viscosity coefficient. The difference between measured and effective viscosity is a function of the polymer type and concentration. Traction measurements did not discriminate mileage formulated oils from those not so designated.

  19. Biomechanical analysis of cervical distraction.

    PubMed

    Miller, L S; Cotler, H B; De Lucia, F A; Cotler, J M; Hume, E L

    1987-11-01

    A biomechanical analysis of cervical distraction is presented, and a model comparing closed reduction of cervical spine dislocations to spring mechanics is developed. Behavior of a spring may be described as F = k delta x where F = distraction force; delta x = elongation of the spring; and k = spring constant. The records and roentgenograms of 24 cervical spine dislocations were reviewed retrospectively. Evaluation of cervical distraction vs traction weight indicates that Ftraction = kneck delta x; where F = traction weight and x = distraction at the injured level. The constant, kneck, is different for bilateral and unilateral dislocations (P less than .001) and is a function of magnitude of injury and neck morphology. As determined in this study, traction weight needed for reduction of facet dislocations may be estimated using the formulae: Ftx = 107.1 lbs/cm (x) unilateral, and Ftx = 76.4 lbs/cm (x) bilateral.

  20. Research on the filtering algorithm in speed and position detection of maglev trains.

    PubMed

    Dai, Chunhui; Long, Zhiqiang; Xie, Yunde; Xue, Song

    2011-01-01

    This paper introduces in brief the traction system of a permanent magnet electrodynamic suspension (EDS) train. The synchronous traction mode based on long stators and track cable is described. A speed and position detection system is recommended. It is installed on board and is used as the feedback end. Restricted by the maglev train's structure, the permanent magnet electrodynamic suspension (EDS) train uses the non-contact method to detect its position. Because of the shake and the track joints, the position signal sent by the position sensor is always aberrant and noisy. To solve this problem, a linear discrete track-differentiator filtering algorithm is proposed. The filtering characters of the track-differentiator (TD) and track-differentiator group are analyzed. The four series of TD are used in the signal processing unit. The result shows that the track-differentiator could have a good effect and make the traction system run normally.

  1. New level of vehicle comfort and vehicle stability via utilisation of the suspensions anti-dive and anti-squat geometry

    NASA Astrophysics Data System (ADS)

    Lindvai-Soos, Daniel; Horn, Martin

    2018-07-01

    In this article a novel vehicle dynamics control concept is designed for a vehicle equipped with wheel individual electric traction machines, electronically controlled brakes and semi-active suspensions. The suspension's cross-couplings between traction forces and vertical forces via anti-dive and anti-squat geometry is utilised in the control concept to improve driving comfort and driving stability. The control concept is divided into one main and two cascaded branches. The main controller consists of a multivariable vehicle dynamics controller and a control allocation scheme to improve the vehicle's driving comfort. The cascaded feedback loops maintain the vehicle's stability according to wheel slip and vehicle sideslip. The performance of the combined vehicle dynamics controller is compared to a standard approach in simulation. It can be stated that the controller piloting semi-active suspensions together with brake and traction devices enables a superior performance regarding comfort and stability.

  2. Relating Cohesive Zone Model to Linear Elastic Fracture Mechanics

    NASA Technical Reports Server (NTRS)

    Wang, John T.

    2010-01-01

    The conditions required for a cohesive zone model (CZM) to predict a failure load of a cracked structure similar to that obtained by a linear elastic fracture mechanics (LEFM) analysis are investigated in this paper. This study clarifies why many different phenomenological cohesive laws can produce similar fracture predictions. Analytical results for five cohesive zone models are obtained, using five different cohesive laws that have the same cohesive work rate (CWR-area under the traction-separation curve) but different maximum tractions. The effect of the maximum traction on the predicted cohesive zone length and the remote applied load at fracture is presented. Similar to the small scale yielding condition for an LEFM analysis to be valid. the cohesive zone length also needs to be much smaller than the crack length. This is a necessary condition for a CZM to obtain a fracture prediction equivalent to an LEFM result.

  3. Electric vehicle drive train with contactor protection

    DOEpatents

    Konrad, Charles E.; Benson, Ralph A.

    1994-01-01

    A drive train for an electric vehicle includes a traction battery, a power drive circuit, a main contactor for connecting and disconnecting the traction battery and the power drive circuit, a voltage detector across contacts of the main contactor, and a controller for controlling the main contactor to prevent movement of its contacts to the closed position when the voltage across the contacts exceeds a predetermined threshold, to thereby protect the contacts of the contactor. The power drive circuit includes an electric traction motor and a DC-to-AC inverter with a capacitive input filter. The controller also inhibits the power drive circuit from driving the motor and thereby discharging the input capacitor if the contacts are inadvertently opened during motoring. A precharging contactor is controlled to charge the input filter capacitor prior to closing the main contactor to further protect the contacts of the main contactor.

  4. Electric vehicle drive train with contactor protection

    DOEpatents

    Konrad, C.E.; Benson, R.A.

    1994-11-29

    A drive train for an electric vehicle includes a traction battery, a power drive circuit, a main contactor for connecting and disconnecting the traction battery and the power drive circuit, a voltage detector across contacts of the main contactor, and a controller for controlling the main contactor to prevent movement of its contacts to the closed position when the voltage across the contacts exceeds a predetermined threshold, to thereby protect the contacts of the contactor. The power drive circuit includes an electric traction motor and a DC-to-AC inverter with a capacitive input filter. The controller also inhibits the power drive circuit from driving the motor and thereby discharging the input capacitor if the contacts are inadvertently opened during motoring. A precharging contactor is controlled to charge the input filter capacitor prior to closing the main contactor to further protect the contacts of the main contactor. 3 figures.

  5. Mean deformation metrics for quantifying 3D cell–matrix interactions without requiring information about matrix material properties

    PubMed Central

    Stout, David A.; Bar-Kochba, Eyal; Estrada, Jonathan B.; Toyjanova, Jennet; Kesari, Haneesh; Reichner, Jonathan S.; Franck, Christian

    2016-01-01

    Mechanobiology relates cellular processes to mechanical signals, such as determining the effect of variations in matrix stiffness with cell tractions. Cell traction recorded via traction force microscopy (TFM) commonly takes place on materials such as polyacrylamide- and polyethylene glycol-based gels. Such experiments remain limited in physiological relevance because cells natively migrate within complex tissue microenvironments that are spatially heterogeneous and hierarchical. Yet, TFM requires determination of the matrix constitutive law (stress–strain relationship), which is not always readily available. In addition, the currently achievable displacement resolution limits the accuracy of TFM for relatively small cells. To overcome these limitations, and increase the physiological relevance of in vitro experimental design, we present a new approach and a set of associated biomechanical signatures that are based purely on measurements of the matrix's displacements without requiring any knowledge of its constitutive laws. We show that our mean deformation metrics (MDM) approach can provide significant biophysical information without the need to explicitly determine cell tractions. In the process of demonstrating the use of our MDM approach, we succeeded in expanding the capability of our displacement measurement technique such that it can now measure the 3D deformations around relatively small cells (∼10 micrometers), such as neutrophils. Furthermore, we also report previously unseen deformation patterns generated by motile neutrophils in 3D collagen gels. PMID:26929377

  6. Modelling, simulation and applications of longitudinal train dynamics

    NASA Astrophysics Data System (ADS)

    Cole, Colin; Spiryagin, Maksym; Wu, Qing; Sun, Yan Quan

    2017-10-01

    Significant developments in longitudinal train simulation and an overview of the approaches to train models and modelling vehicle force inputs are firstly presented. The most important modelling task, that of the wagon connection, consisting of energy absorption devices such as draft gears and buffers, draw gear stiffness, coupler slack and structural stiffness is then presented. Detailed attention is given to the modelling approaches for friction wedge damped and polymer draft gears. A significant issue in longitudinal train dynamics is the modelling and calculation of the input forces - the co-dimensional problem. The need to push traction performances higher has led to research and improvement in the accuracy of traction modelling which is discussed. A co-simulation method that combines longitudinal train simulation, locomotive traction control and locomotive vehicle dynamics is presented. The modelling of other forces, braking propulsion resistance, curve drag and grade forces are also discussed. As extensions to conventional longitudinal train dynamics, lateral forces and coupler impacts are examined in regards to interaction with wagon lateral and vertical dynamics. Various applications of longitudinal train dynamics are then presented. As an alternative to the tradition single wagon mass approach to longitudinal train dynamics, an example incorporating fully detailed wagon dynamics is presented for a crash analysis problem. Further applications of starting traction, air braking, distributed power, energy analysis and tippler operation are also presented.

  7. Data Mining Gets Traction in Education

    ERIC Educational Resources Information Center

    Sparks, Sarah D.

    2011-01-01

    The new and rapidly growing field of educational data mining is using the chaff from data collected through normal school activities to explore learning in more detail than ever, and researchers say the day when educators can make use of Amazon.com-like feedback on student learning behaviors may be closer than most people think. Educational data…

  8. Research Study Towards a MEFFV Electric Armament System

    DTIC Science & Technology

    2004-01-01

    CHPSPerf Inputs Parameter Setting Engine Power (kW) 500 per engine Generator Power (kW) 500/generator Traction Motors Power (kW) 500/side # Battery Pack...Cells in Parallel 2 # Motors in Drive Train 2 Max Power of Traction Motors 200 Minimum Engine Power (kW) 50 Optimum Engine Power (kW) 750 Stop... motors . Other options were examined for the energy storage system. Of particular interest in this regard is the use of the CPA flywheel as the load

  9. A two-field modified Lagrangian formulation for robust simulations of extrinsic cohesive zone models

    NASA Astrophysics Data System (ADS)

    Cazes, F.; Coret, M.; Combescure, A.

    2013-06-01

    This paper presents the robust implementation of a cohesive zone model based on extrinsic cohesive laws (i.e. laws involving an infinite initial stiffness). To this end, a two-field Lagrangian weak formulation in which cohesive tractions are chosen as the field variables along the crack's path is presented. Unfortunately, this formulation cannot model the infinite compliance of the broken elements accurately, and no simple criterion can be defined to determine the loading-unloading change of state at the integration points of the cohesive elements. Therefore, a modified Lagrangian formulation using a fictitious cohesive traction instead of the classical cohesive traction as the field variable is proposed. Thanks to this change of variable, the cohesive law becomes an increasing function of the equivalent displacement jump, which eliminates the problems mentioned previously. The ability of the proposed formulations to simulate fracture accurately and without field oscillations is investigated through three numerical test examples.

  10. Bulk Viscoelastic Contribution to the Wet Sliding Friction of Rubber Compounds

    NASA Astrophysics Data System (ADS)

    Pan, Xiao-Dong

    2002-03-01

    An efficient stopping of an automobile on a wet highway in a rainy day is of obvious importance to the safety of the driving public. Here tire tread made of filled rubber compounds plays an essential role in detremining the wet traction performance. Even though significant progress has been made in improving this tire performance character and much knowledge has been accumulated, there still lacks a coherent fundamental understanding on this dynamic process. Consequently there currently exist no accurate guidelines for designing rubber compounds for better wet traction, and for predicting the wet traction performance of a rubber compound. In this experimental study, a portable British Pendulum Skid Tester has been employed to examine in the laboratory how the rubber compound material properties affect its wet sliding friction on a concrete surface. A dramatic dispaly of the impacts from the compound bulk viscoelastic properties has been observed for the first time. This observation will be discussed in relation to previous results discussed in the literature.

  11. Research on the Filtering Algorithm in Speed and Position Detection of Maglev Trains

    PubMed Central

    Dai, Chunhui; Long, Zhiqiang; Xie, Yunde; Xue, Song

    2011-01-01

    This paper introduces in brief the traction system of a permanent magnet electrodynamic suspension (EDS) train. The synchronous traction mode based on long stators and track cable is described. A speed and position detection system is recommended. It is installed on board and is used as the feedback end. Restricted by the maglev train’s structure, the permanent magnet electrodynamic suspension (EDS) train uses the non-contact method to detect its position. Because of the shake and the track joints, the position signal sent by the position sensor is always aberrant and noisy. To solve this problem, a linear discrete track-differentiator filtering algorithm is proposed. The filtering characters of the track-differentiator (TD) and track-differentiator group are analyzed. The four series of TD are used in the signal processing unit. The result shows that the track-differentiator could have a good effect and make the traction system run normally. PMID:22164012

  12. A variationally coupled FE-BE method for elasticity and fracture mechanics

    NASA Technical Reports Server (NTRS)

    Lu, Y. Y.; Belytschko, T.; Liu, W. K.

    1991-01-01

    A new method for coupling finite element and boundary element subdomains in elasticity and fracture mechanics problems is described. The essential feature of this new method is that a single variational statement is obtained for the entire domain, and in this process the terms associated with tractions on the interfaces between the subdomains are eliminated. This provides the additional advantage that the ambiguities associated with the matching of discontinuous tractions are circumvented. The method leads to a direct procedure for obtaining the discrete equations for the coupled problem without any intermediate steps. In order to evaluate this method and compare it with previous methods, a patch test for coupled procedures has been devised. Evaluation of this variationally coupled method and other methods, such as stiffness coupling and constraint traction matching coupling, shows that this method is substantially superior. Solutions for a series of fracture mechanics problems are also reported to illustrate the effectiveness of this method.

  13. Hidden order in crackling noise during peeling of an adhesive tape.

    PubMed

    Kumar, Jagadish; Ciccotti, M; Ananthakrishna, G

    2008-04-01

    We address the longstanding problem of recovering dynamical information from noisy acoustic emission signals arising from peeling of an adhesive tape subject to constant traction velocity. Using the phase space reconstruction procedure we demonstrate the deterministic chaotic dynamics by establishing the existence of correlation dimension as also a positive Lyapunov exponent in a midrange of traction velocities. The results are explained on the basis of the model that also emphasizes the deterministic origin of acoustic emission by clarifying its connection to stick-slip dynamics.

  14. VISUALIZATION FROM INTRAOPERATIVE SWEPT-SOURCE MICROSCOPE-INTEGRATED OPTICAL COHERENCE TOMOGRAPHY IN VITRECTOMY FOR COMPLICATIONS OF PROLIFERATIVE DIABETIC RETINOPATHY.

    PubMed

    Gabr, Hesham; Chen, Xi; Zevallos-Carrasco, Oscar M; Viehland, Christian; Dandrige, Alexandria; Sarin, Neeru; Mahmoud, Tamer H; Vajzovic, Lejla; Izatt, Joseph A; Toth, Cynthia A

    2018-01-10

    To evaluate the use of live volumetric (4D) intraoperative swept-source microscope-integrated optical coherence tomography in vitrectomy for proliferative diabetic retinopathy complications. In this prospective study, we analyzed a subgroup of patients with proliferative diabetic retinopathy complications who required vitrectomy and who were imaged by the research swept-source microscope-integrated optical coherence tomography system. In near real time, images were displayed in stereo heads-up display facilitating intraoperative surgeon feedback. Postoperative review included scoring image quality, identifying different diabetic retinopathy-associated pathologies and reviewing the intraoperatively documented surgeon feedback. Twenty eyes were included. Indications for vitrectomy were tractional retinal detachment (16 eyes), combined tractional-rhegmatogenous retinal detachment (2 eyes), and vitreous hemorrhage (2 eyes). Useful, good-quality 2D (B-scans) and 4D images were obtained in 16/20 eyes (80%). In these eyes, multiple diabetic retinopathy complications could be imaged. Swept-source microscope-integrated optical coherence tomography provided surgical guidance, e.g., in identifying dissection planes under fibrovascular membranes, and in determining residual membranes and traction that would benefit from additional peeling. In 4/20 eyes (20%), acceptable images were captured, but they were not useful due to high tractional retinal detachment elevation which was challenging for imaging. Swept-source microscope-integrated optical coherence tomography can provide important guidance during surgery for proliferative diabetic retinopathy complications through intraoperative identification of different complications and facilitation of intraoperative decision making.

  15. A technological advance for 21st century obstetricians: the electronically-controlled vacuum extractor.

    PubMed

    Perone, Nicola

    2018-04-25

    To describe an innovative electronically-controlled vacuum extractor (VE) in detail and to illustrate its performance characteristics, as observed in a laboratory study. Thirty simulated, vacuum-assisted deliveries. (1) The ability to measure in real-time of the pull applied and to sound an alert, when the traction approaches the negative pressure under the cup, to prevent its detachment. (2) The recording and printing of a graphic representation of the pull applied (vacuum delivery graph). (3) The emission of a warning signal when the 15-min time limit of continuous cup application on the fetal scalp, is reached. No cup detachment occurred in any of the 15 vacuum-assisted deliveries, in which traction was kept below the adhesive force of the cup [44 lb (20 kg)], except in three cases, due to loss of negative pressure. In the remaining 15 tests, in which traction was greater than the adhesive force of the cup, "pull-offs" inevitably occurred. Furthermore, upon reaching the 15-min time limit of continuous cup application on the fetal cephalic model, a warning signal was emitted, as programmed. Conclusions We demonstrated that the electronically-controlled VE, with its distinctive pull-sensing handle, performs suitably for its intended purposes. The ability of the modernized device to decrease the incidence of cup detachment, secondary to the inadvertent application of excessive traction, may result in considerable safety, medico-legal and didactic advantages.

  16. Neonatal and maternal outcomes of successful manual rotation to correct malposition of the fetal head; A retrospective and prospective observational study.

    PubMed

    Tempest, Nicola; McGuinness, Naomi; Lane, Steven; Hapangama, Dharani K

    2017-01-01

    To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation. Prospective and retrospective observational study. Delivery suite in a tertiary referral teaching hospital in England. A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006-2013. Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section). Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia) and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml) and obstetric anal sphincter injury). Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346) of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349) shoulder dystocia, 2% (7/349) massive obstetric haemorrhage and 1.7% (6/349) obstetric anal sphincter injury, similar to other methods of rotational births. Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training) and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth.

  17. An Alternative Three-Term Decomposition for Single Crystal Deformation Motivated by Non-Linear Elastic Dislocation Solutions

    DTIC Science & Technology

    2014-04-01

    yet fully passed through. This element is free from traction along its external surface , and thus is in a state of self stress. The remainder of...neighbours so that it too is in a state of self stress. External boundaries of the entire slab are also necessarily traction free in this global intermediate...N ⊗ u)dS = 12V0 ∫ [∇u+ (∇u)T]dV0 must vanish in a domain with uniform material properties that is in a state of self stress (that is, a homogeneous

  18. Stress intensity factors in a hollow cylinder containing a radial crack

    NASA Technical Reports Server (NTRS)

    Delale, F.

    1980-01-01

    An exact formulation of the plane elasticity problem for a hollow cylinder or a disk containing a radial crack is given. The crack may be an external edge crack, an internal edge crack, or an embedded crack. It is assumed that on the crack surfaces the shear traction is zero and the normal traction is an arbitrary function of r. For various crack geometries and radius ratios, the numerical results are obtained for a uniform crack surface pressure, for a uniform pressure acting on the inside wall of the cylinder, and for a rotating disk.

  19. Spur-Gear-System Efficiency at Part and Full Load

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    A simple method for predicting the part- and full-load power loss of a steel spur gearset of arbitrary geometry supported by ball bearings is described. The analysis algebraically accounts for losses due to gear sliding, rolling traction, and windage in addition to support-ball-bearing losses. The analysis compares favorably with test data. A theoretical comparison of the component losses indicates that losses due to gear rolling traction, windage, and support bearings are significant and should be included along with gear sliding loss in a calculation of gear-system power loss.

  20. Factors influencing aircraft ground handling performance

    NASA Technical Reports Server (NTRS)

    Yager, T. J.

    1983-01-01

    Problems associated with aircraft ground handling operations on wet runways are discussed and major factors which influence tire/runway braking and cornering traction capability are identified including runway characteristics, tire hydroplaning, brake system anomalies, and pilot inputs. Research results from tests with instrumented ground vehicles and aircraft, and aircraft wet runway accident investigation are summarized to indicate the effects of different aircraft, tire, and runway parameters. Several promising means are described for improving tire/runway water drainage capability, brake system efficiency, and pilot training to help optimize aircraft traction performance on wet runways.