Sample records for national instruments ni

  1. Sterilization of rotary NiTi instruments within endodontic sponges.

    PubMed

    Chan, H W A; Tan, K H; Dashper, S G; Reynolds, E C; Parashos, P

    2015-08-17

    To determine whether the following can be sterilized by autoclaving - endodontic sponges, rotary nickel-titanium (NiTi) instruments within endodontic sponges, and rotary NiTi instruments with rubber stoppers. Sixty-four samples of eight different endodontic sponges (n = 512) were placed into brain heart infusion broth (BHI) for 72 h. An aliquot of this was then spread onto horse blood agar and cultured aerobically and anaerobically to test sterility at purchase. Bacterial suspensions of Enterococcus faecalis, Porphyromonas gingivalis and Geobacillus stearothermophilus in BHI were used to contaminate sterile sponges and rotary NiTi instruments (with and without rubber stoppers) inserted into sponges. The various samples were autoclaved and then cultured aerobically and anaerobically. Success of sterilization was measured qualitatively as no growth. The experiment was repeated with clinically used rotary NiTi instruments (n = 512). All experiments were conducted in quadruplicate. No sponges on purchase had microbial growth when anaerobically cultured but some did when aerobically cultured. All autoclaved sponges and instruments (within or without sponges, and with or without rubber stoppers) were associated with no microbial growth. All nonautoclaved positive control samples showed microbial growth. Autoclaving was effective in the sterilization of sponges and endodontic instruments. Endodontic sponges should be autoclaved before clinical use. For clinical efficiency and cost-effectiveness, rotary NiTi instruments can be sterilized in endodontic sponges without removal of rubber stoppers. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. The Effect of Electrical Treatment on Cyclic Fatigue of NiTi Instruments

    PubMed Central

    Saghiri, Mohammad Ali; Asatourian, Armen; Garcia-Godoy, Franklin; Gutmann, James L.; Lotfi, Mehrdad; Sheibani, Nader

    2016-01-01

    Summary Dentists desire to use NiTi rotary instruments, which do not break inside the root canals of teeth, since the pieces from broken files are difficult to remove. The NiTi rotary instrument breakage is because of cyclic and torsional fatigue. Here the low-voltage (12 V) and high voltage (24 V) electrical treatments were used to enhance the cyclic fatigue of NiTi rotary instruments and increase their durability. In excremental groups, following electrical treatment samples of the NiTi instruments were rotated inside artificial root canals until they broke. Our results showed that electrical treatment with 12-V DC was effective in restoring NiTi instrument’s resistance to cyclic fatigue. The scanning electron microscopy images and fractograph of samples exposed to 12-V electrical treatment showed a more regular texture over the surface with less dimpling on fractured site. These patterns can improve the super elasticity of tested devices during rotational movement, and delay the NiTi instruments separation in root canal preparations. PMID:24798116

  3. A Review of the Various Surface Treatments of NiTi Instruments

    PubMed Central

    Mohammadi, Zahed; Soltani, Mohammad Karim; Shalavi, Sousan; Asgary, Saeed

    2014-01-01

    Since the introduction of engine-driven nickel-titanium (NiTi) instruments, attempts have been made to minimize or eliminate their inherent defects, increase their surface hardness/flexibility and also improve their resistance to cyclic fatigue and cutting efficiency. The various strategies of enhancing instrument surface include ion implantation, thermal nitridation, cryogenic treatment and electropolishing. The purpose of this paper was to review the metallurgy and crystal characteristics of NiTi alloy and to present a general over review of the published articles on surface treatment of NiTi endodontic instruments. PMID:25386201

  4. Application of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments.

    PubMed

    Li, Uei-Ming; Shin, Chow-Shing; Lan, Wan-Hong; Lin, Chun-Pin

    2006-06-01

    The purpose of this study was to investigate the application of nondestructive testing in cyclic fatigue evaluation of endodontic ProFile nickel-titanium (NiTi) rotary instruments. As-received ProFile instruments were made to rotate freely in sloped metal blocks by a contra-angle handpiece mounted on a testing machine. Rotation was interrupted periodically, and the instrument removed and engaged onto a device to monitor its stiffness by using two strain gauges in four different directions. This monitoring method has the potential to be developed into a convenient, nondestructive turnkey system that allows in situ assessment of the integrity of NiTi instruments in the clinic. Upon fracture, which was indicated by a change in instrument stiffness, the fractured surface would be examined under a scanning electron microscope. Microscopic evaluation indicated a small area of fatigue fracture with a large area of final ductile fracture, whereby the latter was the major cyclic failure mode. Based on the results of this study, we concluded that a potential nondestructive integrity assessment method for NiTi rotary instruments was developed.

  5. Do NiTi instruments show defects before separation? Defects caused by torsional fatigue in hand and rotary nickel-titanium (NiTi) instruments which lead to failure during clinical use.

    PubMed

    Chakka, N V Murali Krishna; Ratnakar, P; Das, Sanjib; Bagchi, Anandamy; Sudhir, Sudhir; Anumula, Lavanya

    2012-11-01

    Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.

  6. Fatigue testing of a NiTi rotary instrument. Part 2: Fractographic analysis.

    PubMed

    Cheung, G S P; Darvell, B W

    2007-08-01

    To examine the topographic features of the fracture surface of a NiTi instrument after fatigue failure, and to correlate the measurements of some features with the cyclic load. A total of 212 ProFile rotary instruments were subjected to a rotational-bending test at various curvatures until broken. The fracture surface of all fragments was examined by SEM to identify the crack origins. The crack radius, i.e. extent of the fatigue-crack growth towards the centroid of the cross-section, was also measured, and correlated with the strain amplitude for each instrument. All fracture surfaces revealed the presence of one or more crack origins, a region occupied by microscopic striations, and an area with microscopic dimples. The number of specimens showing multiple crack origins was significantly greater in the group fatigued under water than in air (P < 0.05). A linear relationship between the reciprocal of the square root of the crack radius and the strain amplitude was discernible (P < 0.001), the slopes of which were not significantly different for instruments fatigued in air and water. The fractographic appearance of NiTi engine-files that had failed because of fatigue is typical of that for other metals. The fatigue behaviour of NiTi instruments is adversely affected by water, not only for the low-cycle fatigue life, but also the number of crack origins. There appears to be a critical extent of crack propagation for various strain amplitudes leading to final rupture (akin to the Griffith's criterion for brittle materials).

  7. Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students

    PubMed Central

    Duran-Sindreu, Fernando; Morello-Castro, Sergio; Mercade-Bellido, Montserrat; Bueno-Martínez, Rufino; Roig-Cayón, Miguel

    2012-01-01

    Objective: To evaluate the effect of number of uses, angle and radius of curvature and type of instrument on the fracture of ProTaper rotary instruments when used by undergraduate students. Study Design: Three hundred and seventy-six molars, with a total of 1114 root canals, extracted were instrumented by undergraduate students using ProTaper instruments according to the manufacturer´s recommendations. When fracture occurred, data were collected concerning the number of uses, type of instrument, level of fracture, angle and radius of curvature. ANOVA test were used to determine the influence of type of instrument in the incidence of instrument fracture. Logistic regression model was used to determine the influence of number of uses, angle and radius of curvature in the incidence of instrument fracture. Significance was set at p< 0.05. Results: A total of 37 Ni-Ti rotary instruments fractured during the treatment. Fracture occurred in 9.84% (37/376) of the teeth treated and 3.32% of the canals prepared with Ni-Ti rotary instruments (37/1114). A decrease in the radius of curvature of the canal significantly increased the likelihood of fracture (p=0.0001). Instrument fracture significantly increased as the number of uses increased (p=0.0037). No significant differences were found between the 6 types of ProTaper instruments (p=0.8). A reduction in the angle of curvature did not produce a significant decrease in the incidence of instrument separation (p=0.08). Conclusions: The results of this study imply that instrument fracture is linked to radius of curvature and number of uses. Key words:Fracture, ProTaper ®, root canal preparation, undergraduate students. PMID:24558555

  8. The Effect of Hydrofluoric Acid Surface Treatment on the Cyclic Fatigue Resistance of K3 NiTi Instruments

    PubMed Central

    2017-01-01

    The aim of this study was to investigate the effect of 50% hydrofluoric acid (HF) surface treatment on the cyclic fatigue resistance (CFR) of K3 NiTi instruments. Twenty as-received and twenty HF-treated K3 NiTi instruments were compared in CFR. The surface texture and fracture surface of two instrument groups were examined with a scanning electron microscope (SEM). Additionally, any change of Ni and Ti composition from both instrument groups was investigated using energy dispersive spectrometry. The results were analyzed with t-test. The HF-treated K3 group showed statistically higher cyclic fatigue resistance than as-received K3 group (P < 0.05). HF-treated K3 instruments showed smoother and rounded surface compared to as-received K3 under SEM observation. The fracture surfaces of both groups showed typical patterns of cyclic fatigue fracture. There was no difference in surface Ni and Ti composition between two groups. HF treatment of K3 instruments smoothed the file surface and increased the cyclic fatigue resistance, while it had no effect on surface ion composition and the file fracture pattern. PMID:28539854

  9. Fatigue testing of a NiTi rotary instrument. Part 1: Strain-life relationship.

    PubMed

    Cheung, G S P; Darvell, B W

    2007-08-01

    To examine the fatigue behaviour using a strain-life approach, and to determine the effect of water on the fatigue life of a NiTi rotary instrument. Instruments of one brand of NiTi engine-file (size 25, ProFile 0.04 and 0.06) were subjected to rotational bending either in air or under water, the number of revolutions to fracture (N(f)) being recorded using an optical counter and an electronic break-detection circuit. The effective surface strain amplitude (epsilon(a)) for each specimen was determined from the curvature of the instrument (on a photograph) and the diameter of the fracture cross-section (from a scanning electron micrograph of the fracture surface). Strain was plotted against fatigue life and the low-cycle fatigue (LCF) region identified. Values were examined using two-way analysis of variance for difference between various instrument-environment combinations. A total of 212 instruments were tested. A strain-life relationship typical of metals was found. N(f) declined with an inverse power function dependence on epsilon(a). A fatigue limit was present at about 0.7% strain. The apparent fatigue-ductility exponent, a material constant for the LCF life of metals, was found to be between -0.45 and -0.55. There was a significant effect of the environmental condition on the LCF life, water being more detrimental than air. The fatigue behaviour of NiTi rotary instrument is typical of most metals, provided that the analysis is based on the surface strain amplitude, and showed a high-cycle and a LCF region. The LCF life is adversely affected by water.

  10. Low-cycle fatigue of NiTi rotary instruments of various cross-sectional shapes.

    PubMed

    Cheung, G S P; Darvell, B W

    2007-08-01

    To compare the low-cycle fatigue (LCF) behaviour of some commercial NiTi instruments subjected to rotational bending, a deformation mode similar to an engine-file rotating in a curved root canal, using a strain-life analysis, in water. A total of 286 NiTi rotary instruments from four manufacturers were constrained into a curvature by three rigid, stainless steel pins whilst rotating at a rate of 250 rpm in deionized water until broken. The number of revolutions was recorded using an optical counter and an electronic break-detection circuit. The surface strain amplitude, calculated from the curvature (from a photograph) and diameter of the fracture cross-section (from a scanning electron micrograph), was plotted against the number of cycles to fracture for each instrument. A regression line was fitted to the LCF lives for each brand; the value was compared with that of others using one-way analysis of variance (ANOVA). The number of crack origins observed on the fractographic view was examined with chi-square for differences amongst various groups. A linear strain-life relationship, on logarithmic scales, was obtained for the LCF region with an apparent fatigue-ductility exponent ranging from -0.40 to -0.56. The number of crack-initiation sites, as observed on the fracture cross-section, differed between brands (chi(2), P < 0.05), but not LCF life (one-way ANOVA, P > 0.05). The LCF life of NiTi instruments declines with an inverse power function dependence on surface strain amplitude, but is not affected by the cross-sectional shape of the instrument.

  11. Validated finite element analyses of WaveOne Endodontic Instruments: a comparison between M-Wire and NiTi alloys.

    PubMed

    Bonessio, N; Pereira, E S J; Lomiento, G; Arias, A; Bahia, M G A; Buono, V T L; Peters, O A

    2015-05-01

    To validate torsional analysis, based on finite elements, of WaveOne instruments against in vitro tests and to model the effects of different nickel-titanium (NiTi) materials. WaveOne reciprocating instruments (Small, Primary and Large, n = 8 each, M-Wire) were tested under torsion according to standard ISO 3630-1. Torsional profiles including torque and angle at fracture were determined. Test conditions were reproduced through Finite Element Analysis (FEA) simulations based on micro-CT scans at 10-μm resolution; results were compared to experimental data using analysis of variance and two-sided one sample t-tests. The same simulation was performed on virtual instruments with identical geometry and load condition, based on M-Wire or conventional NiTi alloy. Torsional profiles from FEA simulations were in significant agreement with the in vitro results. Therefore, the models developed in this study were accurate and able to provide reliable simulation of the torsional performance. Stock NiTi files under torsional tests had up to 44.9%, 44.9% and 44.1% less flexibility than virtual M-Wire files at small deflections for Small, Primary and Large instruments, respectively. As deflection levels increased, the differences in flexibility between the two sets of simulated instruments decreased until fracture. Stock NiTi instruments had a torsional fracture resistance up to 10.3%, 8.0% and 7.4% lower than the M-Wire instruments, for the Small, Primary and Large file, respectively. M-Wire instruments benefitted primarily through higher material flexibility while still at low deflection levels, compared with conventional NiTi alloy. At fracture, the instruments did not take complete advantage of the enhanced fractural resistance of the M-Wire material, which determines only limited improvements of the torsional performance. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  12. Experimental and numerical analysis of penetration/removal response of endodontic instrument made of single crystal Cu-based SMA: comparison with NiTi SMA instruments

    NASA Astrophysics Data System (ADS)

    Vincent, M.; Xolin, P.; Gevrey, A.-M.; Thiebaud, F.; Engels-Deutsch, M.; Ben Zineb, T.

    2017-04-01

    This paper presents an experimental and numerical study showing that single crystal shape memory alloy (SMA) Cu-based endodontic instruments can lead to equivalent mechanical performances compared to NiTi-based instruments besides their interesting biological properties. Following a previous finite element analysis (FEA) of single crystal CuAlBe endodontic instruments (Vincent et al 2015 J. Mater. Eng. Perform. 24 4128-39), prototypes with the determined geometrical parameters were machined and experimentally characterized in continuous rotation during a penetration/removal (P/R) protocol in artificial canals. The obtained mechanical responses were compared to responses of NiTi endodontic files in the same conditions. In addition, FEA was conducted and compared with the experimental results to validate the adopted modeling and to evaluate the local quantities inside the instrument as the stress state and the distribution of volume fraction of martensite. The obtained results highlight that single crystal CuAlBe SMA prototypes show equivalent mechanical responses to its NiTi homologous prototypes in the same P/R experimental conditions.

  13. Defect propagation in NiTi rotary instruments: a noncontact optical profilometry analysis.

    PubMed

    Barbosa, I; Ferreira, F; Scelza, P; Neff, J; Russano, D; Montagnana, M; Zaccaro Scelza, M

    2018-04-10

    To evaluate the presence and propagation of defects and their effects on surfaces of nickel-titanium (NiTi) instruments using noncontact, three-dimensional optical profilometry, and to assess the accuracy of this method of investigation. The flute surface areas of instruments from two commercial instrumentation systems, namely Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were assessed and compared before and after performing two instrumentation cycles in simulated root canals in clear resin blocks. All the analyses were conducted on areas measuring 211 × 211 μm, located 3 mm from the tips of the instruments. A quantitative analysis was conducted before and after the first and second instrumentation cycles, using the Sa (average roughness over the measurement field), Sq (root mean square roughness) and Sz (average height over the measurement field) amplitude parameters. All the data were submitted to statistical analysis at a 5% level of significance. There was a significant increase (P = 0.007) in wear in both groups, especially between baseline and the second instrumentation cycle, with significantly higher wear values being observed on WaveOne instruments (Sz median values = 33.68 and 2.89 μm, respectively, for WO and RP groups). A significant increase in surface roughness (P = 0.016 and P = 0.008, respectively, for Sa and Sq) was observed in both groups from the first to the second instrumentation cycle, mostly in WaveOne specimens. Qualitative analysis revealed a greater number of defects on the flute topography of all the instruments after use. More defects were identified in WaveOne Primary instruments compared to Reciproc R25, irrespective of the evaluation stage. The investigation method provided an accurate, repeatable and reproducible assessment of NiTi instruments at different time-points. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. Influence of axial movement on fatigue of PROFILE* NI-TI rotary instruments: an in vitro evaluation

    PubMed Central

    Avoaka, Marie-Chantal; Haïkel, Youssef

    2010-01-01

    The aim of this study was to evaluate the influence of the axial movement and the angle of curve (in degrees) on fatigue of nickel-titanium (Ni-Ti) ProFile’ rotary endodontic instruments. Ni-Ti ProFile’ rotary instruments (Maillefer SA, Ballaigues, Switzerland), 25 mm long in the range of ISO size 15 to 40 with two tapers (0.4 and 0.6) were evaluated. They are divided in two groups: the instruments with axial movement and those without axial movement. The system used to test the fatigue is maintained in mechanical conditions as close as possible to the clinical situation. The axial movement is in the order of 2mm in corono-apical direction with a frequency of 1Hz. The concave radii incorporating a notched V-form for guiding the instruments were: 5; 7,5 and 10 mm. The rotary system is mounted on an electric handpiece and rotated at 350 rpm speed as recommended by the manufacturers. The instruments are rotated until their separation, and the time, in seconds, is recorded. Statístícal evaluation is undertaken using a two-way t-test to identify significant differences between variables in the study (p <0,05). We found significant statistical difference (p<0,05) between Ni-Ti engine drive ProFile’ instruments incorporating an axial movement and the instruments without axial movement with the same radius of curvature, size and taper. The incorporation of the axial movement increases significantly the life-span of the ProFile’ rotary instruments. This should reduce the risk of the instrument separation during the endodontic treatment. PMID:20507289

  15. CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study.

    PubMed

    Nagaraja, Shruthi; Sreenivasa Murthy, B V

    2010-01-01

    Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. Improper preparation can lead to procedural errors like transportation of foramen, uneven dentine thickness, stripping of root canal, formation of ledge, zip, and elbow in curved canals. These procedural errors and their sequel can adversely affect the prognosis of treatment. The present in vitro study aims to evaluate canal preparation based on the following factors: canal transportation, remaining dentine thickness and comparing centering ability between hand Ni-Ti K files and ProTaper rotary Ni-Ti instruments using computed tomography (CT). For evaluation, 30 mesiobuccal roots of maxillary molars were selected. Of these, 15 roots were distributed into two groups where Group 1 included hand instrumentation with Ni-Ti K-files; and Group 2 comprised ProTaper NiTi rotary system. Pre instrumentation and post instrumentation three-dimensional CT images were obtained from root cross-sections that were 1 mm thick from apex to the canal orifice; scanned images were then superimposed and compared. It was observed that the manual technique using hand Ni-Ti K-file produced lesser canal transportation and maintained greater dentine thickness than the rotary ProTaper technique at middle and coronal third and this difference was statistically significant. No significant difference was seen with regard to canal transportation and remaining root dentine at apical levels. With regard to centering ratio, no significant difference was seen between both the groups at all levels. ProTaper should be used judiciously, especially in curved canals, as it causes higher canal transportation and thinning of root dentine at middle and coronal levels. None of the groups showed optimal centering ability.

  16. Influence of axial movement on fatigue of ProFile Ni-Ti rotary instruments: an in vitro evaluation.

    PubMed

    Avoaka, Marie-Chantal; Haïkel, Youssef

    2010-05-01

    The aim of this study was to evaluate the influence of the axial movement and the angle of curve (in degrees) on fatigue of nickel-titanium (Ni-Ti) ProFile rotary endodontic instruments. Ni-Ti ProFile rotary instruments (Maillefer SA, Ballaigues, Switzerland), 25 mm long in the range of ISO size 15 to 40 with two tapers (0.4 and 0.6) were evaluated. They are divided in two groups: the instruments with axial movement and those without axial movement. The system used to test the fatigue is maintained in mechanical conditions as close as possible to the clinical situation. The axial movement is in the order of 2 mm in corono-apical direction with a frequency of 1 Hz. The concave radii incorporating a notched V-form for guiding the instruments were: 5; 7,5 and 10 mm. The rotary system is mounted on an electric handpiece and rotated at 350 rpm speed as recommended by the manufacturers. The instruments are rotated until their separation, and the time, in seconds, is recorded. Statistical evaluation is undertaken using a two-way t-test to identify significant differences between variables in the study (p <0.05). We found significant statistical difference (p<0.05) between Ni-Ti engine drive ProFile instruments incorporating an axial movement and the instruments without axial movement with the same radius of curvature, size and taper.The incorporation of the axial movement increases significantly the life-span of the ProFile rotary instruments. This should reduce the risk of the instrument separation during the endodontic treatment.

  17. CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study

    PubMed Central

    Nagaraja, Shruthi; Sreenivasa Murthy, B V

    2010-01-01

    Background: Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. Improper preparation can lead to procedural errors like transportation of foramen, uneven dentine thickness, stripping of root canal, formation of ledge, zip, and elbow in curved canals. These procedural errors and their sequel can adversely affect the prognosis of treatment. Aim/Objectives: The present in vitro study aims to evaluate canal preparation based on the following factors: canal transportation, remaining dentine thickness and comparing centering ability between hand Ni-Ti K files and ProTaper rotary Ni-Ti instruments using computed tomography (CT). Materials and Methods: For evaluation, 30 mesiobuccal roots of maxillary molars were selected. Of these, 15 roots were distributed into two groups where Group 1 included hand instrumentation with Ni-Ti K-files; and Group 2 comprised ProTaper NiTi rotary system. Pre instrumentation and post instrumentation three-dimensional CT images were obtained from root cross-sections that were 1 mm thick from apex to the canal orifice; scanned images were then superimposed and compared. Result: It was observed that the manual technique using hand Ni-Ti K-file produced lesser canal transportation and maintained greater dentine thickness than the rotary ProTaper technique at middle and coronal third and this difference was statistically significant. No significant difference was seen with regard to canal transportation and remaining root dentine at apical levels. With regard to centering ratio, no significant difference was seen between both the groups at all levels. Conclusion: ProTaper should be used judiciously, especially in curved canals, as it causes higher canal transportation and thinning of root dentine at middle and coronal levels. None of the groups showed optimal centering ability. PMID:20582214

  18. Noncontact three-dimensional evaluation of surface alterations and wear in NiTi endodontic instruments.

    PubMed

    Ferreira, Fabiano Guerra; Barbosa, Igor Bastos; Scelza, Pantaleo; Montagnana, Marcello Bulhões; Russano, Daniel; Neff, John; Scelza, Miriam Zaccaro

    2017-09-28

    The aim of this study was to undertake a qualitative and quantitative assessment of nanoscale alterations and wear on the surfaces of nickel-titanium (NiTi) endodontic instruments, before and after use, through a high-resolution, noncontact, three-dimensional optical profiler, and to verify the accuracy of the evaluation method. Cutting blade surfaces of two different brands of NiTi endodontic instruments, Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were examined and compared before and after two uses in simulated root canals made in clear resin blocks. The analyses were performed on three-dimensional images which were obtained from surface areas measuring 211 × 211 µm, located 3 mm from their tips. The quantitative evaluation of the samples was conducted before and after the first and second usage, by the recordings of three amplitude parameters. The data were subjected to statistical analysis at a 5% level of significance. The results revealed statistically significant increases in the surface wear of both instruments groups after the second use. The presence of irregularities was found on the surface topography of all the instruments, before and after use. Regardless of the evaluation stage, most of the defects were observed in the WaveOne instruments. The three-dimensional technique was suitable and effective for the accurate investigation of the same surfaces of the instruments in different periods of time.

  19. Comparative analysis of torsional and bending behavior through finite-element models of 5 Ni-Ti endodontic instruments.

    PubMed

    Arbab-Chirani, Reza; Chevalier, Valérie; Arbab-Chirani, Shabnam; Calloch, Sylvain

    2011-01-01

    The objectives of this study were to compare numerically the bending and torsional mechanical behavior of 5 endodontic rotary Ni-Ti instruments with equivalent size and various designs for tapers, pitch, and cutting blades.First, the geometries of Hero (20/0.06), HeroShaper (20/0.06), ProFile (20/0.06), Mtwo (20/0.06), and ProTaper F1 were generated by finite element code. Then, the 2 most representative clinical loadings, i.e., bending and torsion, were studied with an ad hoc model for the superelasticity of Ni-Ti. Bending was generated by tip deflection and torsion by a constant twist-angle of the tip. Mechanical behavior of these 5 endodontic rotary Ni-Ti instruments could be evaluated and compared. Protaper F1 presented the greatest level of bending stress and torque. Hero and HeroShaper were more rigid than ProFile and Mtwo. This numerical comparison evaluated the effects of the geometrical parameters on the instrumental mechanical behavior. The 5 endodontic instruments, investigated in the present study, do not have the same bending and torsional mechanical behavior. Each clinician must be aware of these behavior differences so as to use the adequate file according to the clinical situation and to the manufacturer's recommendations. Copyright © 2011 Mosby, Inc. All rights reserved.

  20. SEM analysis of defects and wear on Ni-Ti rotary instruments.

    PubMed

    Arantes, Werington Borges; da Silva, Celso Monteiro; Lage-Marques, José Luiz; Habitante, Sandramarcia; da Rosa, Luiz Carlos Laureano; de Medeiros, João Marcelo Ferreira

    2014-01-01

    SEM analysis of endodontic instruments from a Ni-Ti rotary system was assessed, before and after using them, considering their defects and deformations. Twenty Twisted File®, BioRąCe®, Mtwo®, and EndoWave® instruments were micrographed at 190× magnification. The files were washed and micrographed again to view alterations as to the presence or absence of irregular edges, grooves, microcavities, and scraping. Simulated root canal preparations were performed using these instruments. The instruments were cleaned and received a microscopic analysis after being used five times. After analysis tests were tested using Fisher's exact test and Kappa to evaluate the concordance among examiners. There was a statistically significant difference with respect to deformations between Twisted File® and other instruments (p < 0.05). There was no statistically significant difference in strains between the other groups (p > 0.05). All Twisted File® instruments showed the same defects; however damage were lower than those found in BioRace® and Mtwo®. The Endowave® did not show the same defects. In accordance with the data we conclude that the presence of defects was higher in Twisted File® instruments as the instruments and BioRace® Mtwo® brand, the defect rate was smaller and Endowave® instruments had no defects. Regarding the presence of wear after five uses among the groups all instruments showed changes in their cutting blades. © 2014 Wiley Periodicals, Inc.

  1. Movement kinematics and cyclic fatigue of NiTi rotary instruments: a systematic review.

    PubMed

    Ferreira, F; Adeodato, C; Barbosa, I; Aboud, L; Scelza, P; Zaccaro Scelza, M

    2017-02-01

    The aim of this review was to provide a detailed analysis of the literature concerning the correlation between different movement kinematics and the cyclic fatigue resistance of NiTi rotary endodontic instruments. From June 2014 to August 2015, four independent reviewers comprehensively and systematically searched the Medline (PubMed), EMBASE, Web of Science, Scopus and Google Scholar databases for works published since January 2005, using the following search terms: endodontics; nickel-titanium rotary files; continuous rotation; reciprocating motion; cyclic fatigue. In addition to the electronic searches, manual searches were performed to include articles listed in the reference sections of high-impact published articles that were not indexed in the databases. Laboratory studies in English language were considered for this review. The electronic and manual searches resulted in identification of 75 articles. Based on the inclusion criteria, 32 articles were selected for analysis of full-text copies. Specific analysis was then made of 20 articles that described the effects of reciprocating and continuous movements on cyclic fatigue of the instruments. A wide range of testing conditions and methodologies have been used to compare the cyclic fatigue resistance of rotary endodontic instruments. Most studies report that reciprocating motion improves the fatigue resistance of endodontic instruments, compared to continuous rotation, independent of other variables such as the speed of rotation, the angle or radius of curvature of simulated canals, geometry and taper, or the surface characteristics of the NiTi instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Modularized Parallel Neutron Instrument Simulation on the TeraGrid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Meili; Cobb, John W; Hagen, Mark E

    2007-01-01

    In order to build a bridge between the TeraGrid (TG), a national scale cyberinfrastructure resource, and neutron science, the Neutron Science TeraGrid Gateway (NSTG) is focused on introducing productive HPC usage to the neutron science community, primarily the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). Monte Carlo simulations are used as a powerful tool for instrument design and optimization at SNS. One of the successful efforts of a collaboration team composed of NSTG HPC experts and SNS instrument scientists is the development of a software facility named PSoNI, Parallelizing Simulations of Neutron Instruments. Parallelizing the traditional serialmore » instrument simulation on TeraGrid resources, PSoNI quickly computes full instrument simulation at sufficient statistical levels in instrument de-sign. Upon SNS successful commissioning, to the end of 2007, three out of five commissioned instruments in SNS target station will be available for initial users. Advanced instrument study, proposal feasibility evalua-tion, and experiment planning are on the immediate schedule of SNS, which pose further requirements such as flexibility and high runtime efficiency on fast instrument simulation. PSoNI has been redesigned to meet the new challenges and a preliminary version is developed on TeraGrid. This paper explores the motivation and goals of the new design, and the improved software structure. Further, it describes the realized new fea-tures seen from MPI parallelized McStas running high resolution design simulations of the SEQUOIA and BSS instruments at SNS. A discussion regarding future work, which is targeted to do fast simulation for automated experiment adjustment and comparing models to data in analysis, is also presented.« less

  3. Instrumentation Guidelines for the Advanced National Seismic System

    USGS Publications Warehouse

    Working Group on Instrumentation, Siting

    2008-01-01

    This document provides guidelines for the seismic-monitoring instrumentation used by long-term earthquake-monitoring stations that will sense ground motion, digitize and store the resulting signals in a local data acquisition unit, and optionally transmit these digital data. These guidelines are derived from specifications and requirements for data needed to address the nation's emergency response, engineering, and scientific needs as identified in U.S. Geological Survey Circular 1188 (1999). Data needs are discussed in terms of national, regional, and urban scales of monitoring in section 3. Functional performance specifications for instrumentation are introduced in section 4.3 and discussed in detail in section 6 in terms of instrument classes and definitions described in section 5. System aspects and testing recommendations are discussed in sections 7 and 8, respectively. Although U.S. Geological Survey Circular 1188 (1999) recommends that the Advanced National Seismic System (ANSS) include portable instrumentation, performance specifications for this element are not specifically addressed in this document. Nevertheless, these guidelines are largely applicable to portable instrumentation. Volcano monitoring instrumentation is also beyond the scope of this document. Guidance for ANSS structural-response monitoring is discussed briefly herein but details are deferred to the ANSS document by the ANSS Structural Response Monitoring Committee (U.S. Geological Survey, 2005). Aspects of station planning, siting, and installation other than instrumentation are beyond the scope of this document.

  4. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems

    PubMed Central

    DUQUE, Jussaro Alves; VIVAN, Rodrigo Ricci; CAVENAGO, Bruno Cavalini; AMOROSO-SILVA, Pablo Andrés; BERNARDES, Ricardo Affonso; de VASCONCELOS, Bruno Carvalho; DUARTE, Marco Antonio Hungaro

    2017-01-01

    Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion. PMID:28198973

  5. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems.

    PubMed

    Duque, Jussaro Alves; Vivan, Rodrigo Ricci; Cavenago, Bruno Cavalini; Amoroso-Silva, Pablo Andrés; Bernardes, Ricardo Affonso; Vasconcelos, Bruno Carvalho de; Duarte, Marco Antonio Hungaro

    2017-01-01

    This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn's tests. For the comparison of data between groups, the Mann-Whitney test was used. In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.

  6. Dental students' perceptions about the endodontic treatments performed using NiTi rotary instruments and hand stainless steel files.

    PubMed

    Martins, Renata Castro; Seijo, Marília Oliveira Saraiva; Ferreira, Efigênia Ferreira; Paiva, Saul Martins; Ribeiro Sobrinho, Antônio Paulino

    2012-01-01

    This study evaluated the perceptions of Brazilian undergraduate dental students about the endodontic treatments performed using NiTi rotary instruments and hand stainless steel. Data were collected using a questionnaire administered to undergraduate dental students enrolled in endodontic disciplines. The students were divided into 3 groups: G1, students who had treated straight canals with SS hand instruments; G2, students who had treated curved canals with SS hand instruments; and G3, students who had treated both straight and curved canals with NiTi rotary instruments. The number of endodontic treatments performed, types of treated teeth, students' learning, time spent, encountered difficulties, quality of endodontic treatment and characteristics of the employed technique were analyzed. There was a 91.3% rate of return for the questionnaires. Mandibular molars were the most frequently treated teeth, followed by maxillary incisors. The Kruskal-Wallis test showed no differences in learning (p=0.528) or in the characteristics of the technique employed (p=0.560) among the three groups. G3 students performed a greater number of endodontic treatments (p<0.001) in a smaller time (p<0.001) than did G1 and G2 students. Difficulties were reported primarily by students in G2 and G3 compared with G1 (p=0.048). The quality of endodontic treatments differed only between G1 and G2 (p=0.045). The use of NiTi rotary instruments should be included in undergraduate dental curriculum, contributing to the increase of patients assisted and consequently to improve the clinical experience of the students.

  7. Comparative evaluation of apically extruded debris during root canal instrumentation using two Ni-Ti single file rotary systems: An in vitro study.

    PubMed

    Singbal, Kiran; Jain, Disha; Raja, Kranthi; Hoe, Tan Ming

    2017-01-01

    Apical extrusion of debris during instrumentation is detrimental to the patient. The aim of this study was to evaluate the apical extrusion of debris during root canal instrumentation using two single file rotary Ni-Ti systems. Thirty freshly extracted mandibular premolars with straight roots were sterilized and divided into two groups instrumented using: One Shape rotary Ni-Ti system with Endoflare orifice shaper (Group 1) and Neo-Niti rotary Ni-Ti system with C1 orifice shaper (Group 2). Preweighed Eppendorf tubes fitted for each tooth before instrumentation. During instrumentation, 1 mL of distilled water with a 30-gauge needle was used to irrigate after every instrument. Tips of the tooth were irrigated with 2 ml distilled water after removal from Eppendorf tubes. The total volume of irrigant in each group was the same 8 ml. All tubes were incubated at 68°C for 15 days and subsequently weighed. The difference between pre- and post-debris weights was calculated, and statistical analysis was performed using independent t -test and level of significance was set at 0.05. The difference between pre- and post-weights was significantly greater for the One Shape system. The Neolix Niti single file was associated with less extrusion compared to One Shape single file system.

  8. Comparative evaluation of apically extruded debris during root canal instrumentation using two Ni-Ti single file rotary systems: An in vitro study

    PubMed Central

    Singbal, Kiran; Jain, Disha; Raja, Kranthi; Hoe, Tan Ming

    2017-01-01

    Background: Apical extrusion of debris during instrumentation is detrimental to the patient. Aim: The aim of this study was to evaluate the apical extrusion of debris during root canal instrumentation using two single file rotary Ni-Ti systems. Materials and Methods: Thirty freshly extracted mandibular premolars with straight roots were sterilized and divided into two groups instrumented using: One Shape rotary Ni-Ti system with Endoflare orifice shaper (Group 1) and Neo-Niti rotary Ni-Ti system with C1 orifice shaper (Group 2). Preweighed Eppendorf tubes fitted for each tooth before instrumentation. During instrumentation, 1 mL of distilled water with a 30-gauge needle was used to irrigate after every instrument. Tips of the tooth were irrigated with 2 ml distilled water after removal from Eppendorf tubes. The total volume of irrigant in each group was the same 8 ml. All tubes were incubated at 68°C for 15 days and subsequently weighed. The difference between pre- and post-debris weights was calculated, and statistical analysis was performed using independent t-test and level of significance was set at 0.05. Results: The difference between pre- and post-weights was significantly greater for the One Shape system. Conclusions: The Neolix Niti single file was associated with less extrusion compared to One Shape single file system. PMID:28855748

  9. Advantages and disadvantages of new torque-controlled endodontic motors and low-torque NiTi rotary instrumentation.

    PubMed

    Gambarini, G

    2001-12-01

    The main problem with the NiTi rotary instrumentation technique is instrument failure. During shaping procedures, rotary instruments might lock and/or screw into canals and, consequently, be subjected to high levels of stress. This may frequently lead to instrument separation or deformation. If a high-torque motor is used, the applied forces are usually very high and the instrument-fracture limit is often exceeded, thus increasing the risk of intracanal failure. A possible solution of this problem is to use a low-torque endodontic motor, which operates below the maximum permissible torque limit of each and every rotary instrument. During clinical instrumentation of root canals, if a torque-controlled motor is loaded right up to the instrument-specific torque, the motor stops momentarily and/or starts rotating counter-clockwise (auto-reverse function) to disengage the locked instrument. These safety mechanisms were developed to reduce the risk of instrument fracture. The author fully discusses the rationale for selecting lower torque values in everyday endodontic practice, and provides clinicians with useful information on the advantages and disadvantages of new endodontic motors with torque control.

  10. Efficacy of reciprocating and rotary NiTi instruments for retreatment of curved root canals assessed by micro-CT.

    PubMed

    Rödig, T; Reicherts, P; Konietschke, F; Dullin, C; Hahn, W; Hülsmann, M

    2014-10-01

    To compare the efficacy of reciprocating and rotary NiTi-instruments in removing filling material from curved root canals using micro-computed tomography. Sixty curved root canals were prepared and filled with gutta-percha and sealer. After determination of root canal curvatures and radii in two directions as well as volumes of filling material, the teeth were assigned to three comparable groups (n = 20). Retreatment was performed using Reciproc, ProTaper Universal Retreatment or Hedström files. Percentages of residual filling material and dentine removal were assessed using micro-CT imaging. Working time and procedural errors were recorded. Statistical analysis was performed by variance procedures. No significant differences amongst the three retreatment techniques concerning residual filling material were detected (P > 0.05). Hedström files removed significantly more dentine than ProTaper Universal Retreatment (P < 0.05), but the difference concerning dentine removal between both NiTi systems was not significant (P > 0.05). Reciproc and ProTaper Universal Retreatment were significantly faster than Hedström files (P = 0.0001). No procedural errors such as instrument fracture, blockage, ledging or perforation were detected for Hedström files. Three perforations were recorded for ProTaper Universal Retreatment, and in both NiTi groups, one instrument fracture occured. Remnants of filling material were observed in all samples with no significant differences between the three techniques. Hedström files removed significantly more dentine than ProTaper Universal Retreatment, but no significant differences between both NiTi systems were detected. Procedural errors were observed with ProTaper Universal Retreatment and Reciproc. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. Comparison of air-driven vs electric torque control motors on canal centering ability by ProTaper NiTi rotary instruments.

    PubMed

    Zarei, Mina; Javidi, Maryam; Erfanian, Mahdi; Lomee, Mahdi; Afkhami, Farzaneh

    2013-01-01

    Cleaning and shaping is one of the most important phases in root canal therapy. Various rotary NiTi systems minimize accidents and facilitate the shaping process. Todays NiTi files are used with air-driven and electric handpieces. This study compared the canal centering after instrumentation using the ProTaper system using Endo IT, electric torque-control motor, and NSK air-driven handpiece. This ex vivo randomized controlled trial study involved 26 mesial mandibular root canals with 10 to 35° curvature. The roots were randomly divided into 2 groups of 13 canals each. The roots were mounted in an endodontic cube with acrylic resin, sectioned horizontally at 2, 6 and 10 mm from the apex and then reassembled. The canals were instrumented according to the manufacturer's instructions using ProTaper rotary files and electric torque-control motors (group 1) or air-driven handpieces (group 2). Photographs of the cross-sections included shots before and after instrumentation, and image analysis was performed using Photoshop software. The centering ability and canal transportation was also evaluated. Repeated measurement and independent t-test provided statistical analysis of canal transportation. The comparison of the rate of transportation toward internal or external walls between the two groups was not statistically significant (p = 0.62). Comparison of the rate of transportation of sections within one group was not significant (p = 0.28). Use of rotary NiTi file with either electric torquecontrol motor or air-driven handpiece had no effect on canal centering. NiTi rotary instruments can be used with air-driven motors without any considerable changes in root canal anatomy, however it needs the clinician to be expert.

  12. A comparison of three Ni-Ti rotary instruments in apical transportation.

    PubMed

    Javaheri, Homan Hossein; Javaheri, Ghasem Hossein

    2007-03-01

    The purpose of this study was to compare apical transportation and changes in canal curvature of three nickel-titanium (Ni-Ti) rotary instruments: Hero 642, RaCe, and ProTaper. Mesiobuccal canals of 60 maxillary first molars (with angles of curvature between 25 degrees and 35 degrees) were prepared with a torque-control, low-speed engine. Canals were prepared using the crown-down technique to the size of #30. Using a radiographic platform, reproducible preinstrumentation and postinstrumentation radiographs were taken. A computer analysis allowed magnification and superimposition of the images. The central axes of initial and final instruments were radiographically superimposed to measure transportation at 1 mm from WL. Data were analyzed using repeated-measures ANOVA. A statistically significant difference in apical transportation was found in ProTaper group. The results suggest that ProTaper file system be implemented in combination with other less tapered more flexible systems, like RaCe, in preparing curved canals.

  13. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments.

    PubMed

    Pereira, Erika S J; Gomes, Renata O; Leroy, Agnès M F; Singh, Rupinderpal; Peters, Ove A; Bahia, Maria G A; Buono, Vicente T L

    2013-12-01

    Comparison of physical and mechanical properties of one conventional and a new NiTi wire, which had received an additional thermomechanical treatment. Specimens of both conventional (NiTi) and the new type of wire, called M-Wire (MW), were subjected to tensile and three-point bending tests, Vickers microhardness measurements, and to rotating-bending fatigue tests at a strain-controlled level of 6%. Fracture surfaces were observed by scanning electron microscopy and the non-deformed microstructures by transmission electron microscopy. The thermomechanical treatment applied to produce the M-Wire apparently increased the tensile strength and Vickers microhardness of the material, but its apparent Young modulus was smaller than that of conventionally treated NiTi. The three-point bending tests showed a higher flexibility for MW which also exhibited a significantly higher number of cycles to failure. M-Wire presented mechanical properties that can render endodontic instruments more flexible and fatigue resistant than those made with conventionally processed NiTi wires. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion.

    PubMed

    Gambarini, G; Gergi, R; Naaman, A; Osta, N; Al Sudani, D

    2012-09-01

    To evaluate the cyclic fatigue fracture resistance of engine-driven twisted file (TF) instruments under reciprocating movement. A sample of 30 size 25, 0.08 taper NiTi TF instruments was tested in a simulated canal with 60˚ angle of curvature and a 3 mm radius. During mechanical testing, different movement kinematics were used at a constant speed, which resulted in three experimental groups (each group n = 10). The instruments from the first group (G1) were rotated until fracture occurred. The instruments in the second (G2) and third group (G3) were driven under reciprocating movement with different angles of reciprocation. The time of fracture for each instrument was measured, and statistical analysis was performed using one-way analysis of variance followed by Tukey's Honestly Significant Different test. Reciprocating movement resulted in a significantly longer cyclic fatigue life (P < 0.0001) when compared with continuous rotation. No difference was found between reciprocation 150° clockwise/30° counterclockwise (CW/CCW) and 30° CW/150° CCW. The reciprocating movement was associated with an extended cyclic fatigue life of the TF size 0.25, 0.08 taper instruments in comparison with conventional rotation. © 2012 International Endodontic Journal.

  15. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni- Ti files - An In-Vitro SEM study.

    PubMed

    Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi

    2014-02-01

    Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. A comparative study consisting of 50 subjects randomized into two groups - 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files

  16. Effects of NiTi rotary and reciprocating instruments on debris and smear layer scores: an SEM evaluation.

    PubMed

    Poggio, Claudio; Dagna, Alberto; Chiesa, Marco; Scribante, Andrea; Beltrami, Riccardo; Colombo, Marco

    2014-12-30

    The purpose of the present study was to investigate the cleaning efficacy of 2 different nickel-titanium (NiTi) rotary systems: a new single system Reciproc compared with the rotary full sequence Mtwo. The amount of debris and the morphology of smear layer were the parameters for the evaluation of the cleanliness of root canals. The null hypothesis of the study was that there would be no significant difference in debris scores and smear layer scores between the 2 systems. 
 Forty single-rooted freshly extracted teeth were selected and divided into 2 groups. For each group, all root canals were shaped with 2 different NiTi instruments (Mtwo and Reciproc) and irrigated with 5.25% NaOCl and 17% ethylenediaminetetraacetic acid (EDTA) solutions by 3 trained operators. Specimens were fractured longitudinally and prepared for scanning electron microscopy (SEM) analysis at a standard magnification of ×5,000. The presence/absence of smear layer and the presence/absence of debris at the coronal, middle and apical third of each canal were evaluated using two 5-step scales for scores. Numeric data were analyzed using the Kruskal-Wallis and Mann-Whitney U statistical tests, and significance was set at a P value <0.05. 
 This study revealed significant differences among the various groups. The Mtwo group presented significantly lower smear layer scores than the Reciproc group (P<0.01) in the middle and apical third of the canal. 
 Conventional continuous rotary NiTi instruments associated with 5.25% NaOCl and 17% EDTA solutions seem to be better for obtaining clean dentinal canal walls. Reciprocating instruments leave a higher quantity of smear layer which covers dentinal walls and dentinal tubules.

  17. Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments.

    PubMed

    Shen, Ya; Zhou, Hui-Min; Zheng, Yu-Feng; Campbell, Les; Peng, Bin; Haapasalo, Markus

    2011-11-01

    To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys and developed new manufacturing processes for the fabrication of NiTi files. This study aimed to examine the phase transformation behavior and microstructure of NiTi instruments from a novel controlled memory NiTi wire (CM wire). Instruments of EndoSequence (ES), ProFile (PF), ProFile Vortex (Vortex), Twisted Files (TF), Typhoon (TYP), and Typhoon™ CM (TYP CM), all size 25/.04, were examined by differential scanning calorimetry (DSC) and x-ray diffraction (XRD). Microstructures of etched instruments were observed by optical microscopy and scanning electron microscopy with x-ray energy-dispersive spectrometric (EDS) analyses. The DSC analyses showed that each segment of the TYP CM and Vortex instruments had an austenite transformation completion or austenite-finish (A(f)) temperature exceeding 37°C, whereas the NiTi instruments made from conventional superelastic NiTi wire (ES, PF, and TYP) and TF had A(f) temperatures substantially below mouth temperature. The higher A(f) temperature of TYP CM instruments was consistent with a mixture of austenite and martensite structure, which was observed at room temperature with XRD. All NiTi instruments had room temperature martensite microstructures consisting of colonies of lenticular features with substantial twinning. EDS analysis indicated that the precipitates in all NiTi instruments were titanium-rich, with an approximate composition of Ti(2)Ni. The TYP CM and Vortex instruments with heat treatment contribute to increase austenite transformation temperature. The CM instrument has significant changes in the phase transformation behavior, compared with conventional superelastic NiTi instruments. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Efficacy of D-RaCe and ProTaper Universal Retreatment NiTi instruments and hand files in removing gutta-percha from curved root canals - a micro-computed tomography study.

    PubMed

    Rödig, T; Hausdörfer, T; Konietschke, F; Dullin, C; Hahn, W; Hülsmann, M

    2012-06-01

    To compare the efficacy of two rotary NiTi retreatment systems and Hedström files in removing filling material from curved root canals. Curved root canals of 57 extracted teeth were prepared using FlexMaster instruments and filled with gutta-percha and AH Plus. After determination of root canal curvatures and radii in two directions, the teeth were assigned to three identical groups (n = 19). The root fillings were removed with D-RaCe instruments, ProTaper Universal Retreatment instruments or Hedström files. Pre- and postoperative micro-CT imaging was used to assess the percentage of residual filling material as well as the amount of dentine removal. Working time and procedural errors were recorded. Data were analysed using analysis of covariance and analysis of variance procedures. D-RaCe instruments were significantly more effective than ProTaper Universal Retreatment instruments and Hedström files (P < 0.05). Hedström files removed significantly less dentine than the rotary NiTi systems (P < 0.0001). D-RaCe instruments were significantly faster compared to both other groups (P < 0.05). No procedural errors such as instrument fracture, blockage, ledging or perforation were detected in the Hedström group. In the ProTaper group, four instrument fractures and one lateral perforation were observed. Five instrument fractures were recorded for D-RaCe. D-RaCe instruments were associated with significantly less residual filling material than ProTaper Universal Retreatment instruments and hand files. Hedström files removed significantly less dentine than both rotary NiTi systems. Retreatment with rotary NiTi systems resulted in a high incidence of procedural errors. © 2012 International Endodontic Journal.

  19. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni- Ti files - An In-Vitro SEM study

    PubMed Central

    Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi

    2014-01-01

    Background: Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. Materials & Methods: A comparative study consisting of 50 subjects randomized into two groups – 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Results: Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Conclusions: Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual

  20. VizieR Online Data Catalog: NiI transition probability measurements (Wood+, 2014)

    NASA Astrophysics Data System (ADS)

    Wood, M. P.; Lawler, J. E.; Sneden, C.; Cowan, J. J.

    2014-04-01

    As in much of our previous branching fraction work, this NiI branching fraction study makes use of archived FTS data from both the 1.0m Fourier Transform Spectrometer (FTS) previously at the National Solar Observatory (NSO) on Kitt Peak and the Chelsea Instruments FT500 UV FTS at Lund University in Sweden. Table 1 lists the 37 FTS spectra used in our NiI branching fraction study. All NSO spectra, raw interferograms, and header files are available in the NSO electronic archives. The 80 CCD frames of spectra from commercial Ni HCD lamps of the echelle spectrograph are listed in Table 2. (6 data files).

  1. Comparison of apical transportation between ProFile and ProTaper NiTi rotary instruments.

    PubMed

    Iqbal, M K; Firic, S; Tulcan, J; Karabucak, B; Kim, S

    2004-06-01

    To use a newly developed radiographic technique to compare apical transportation and loss of working length (WL) between.06 taper ProFile Series 29 and ProTaper nickel-titanium (NiTi) rotary instruments in vitro. Mesio-buccal canals of 40 extracted mandibular molars were randomly divided into two groups. Group 1 was instrumented with ProFile and group 2 with ProTaper instruments according to the manufacturers' directions. A specially constructed radiographic jig with a Schick digital radiographic system (Schick Technologies Inc., Long Island City, NY, USA) was used to take pre- and postoperative radiographs of the samples at predetermined angulations. Using AutoCAD 2000 (Autodesk Inc., San Rafael, CA, USA), the central axes of initial and final instruments were radiographically superimposed to determine the loss of WL and degree of transportation at D(0), D(1), D(2) and D(4) from the WL. Data were analysed using repeated-measures anova. A statistically significant difference in apical transportation was found at the D(4) level between the two groups (P = 0.05). There was no statistical significance regarding postinstrumentation change in WL between groups. Spearman's Bivariate Correlation analysis indicated no statistically significant relationship between the radius of curvature and transportation. The results indicate that both ProTaper and ProFile instruments are comparable to each other in regards to their ability to optimally enlarge root canal with minimal transportation and loss of WL in vitro.

  2. Structural Characterisation and Mechanical FE Analysis of Conventional and M-Wire Ni-Ti Alloys Used in Endodontic Rotary Instruments

    PubMed Central

    Montalvão, Diogo; Alçada, Francisca Sena; Braz Fernandes, Francisco Manuel; de Vilaverde-Correia, Sancho

    2014-01-01

    The purpose of this study is to understand how the M-Wire alloy conditions the mechanical flexibility of endodontic rotary files at body temperature.Two different rotary instruments, a Profile GT 20/.06 and a Profile GT Series X 20/.06, were selected due to their geometrical similarity and their different constituent alloy. GT series X files are made from M-Wire, a Ni-Ti alloy allegedly having higher flexibility at body temperature. Both files were analysed by X-Ray Diffraction and Differential Scanning Calorimetry to investigate phase transformations and the effects of working temperature on these different alloys. Mechanical behaviour was assessed by means of static bending and torsional Finite Element simulations, taking into account the nonlinear superelastic behaviour of Ni-Ti materials. It was found that GT files present austenitic phase at body temperature, whereas GT series X present R-phase at temperatures under 40°C with a potential for larger flexibility. For the same load conditions, simulations showed that the slight geometrical differences between the two files do not introduce great disagreement in the instruments' mechanical response. It was confirmed that M-Wire increases the instrument's flexibility, mainly due to the presence of R-phase at body temperature. PMID:24574937

  3. Structural characterisation and mechanical FE analysis of conventional and M-Wire Ni-Ti alloys used in endodontic rotary instruments.

    PubMed

    Montalvão, Diogo; Alçada, Francisca Sena; Braz Fernandes, Francisco Manuel; de Vilaverde-Correia, Sancho

    2014-01-01

    The purpose of this study is to understand how the M-Wire alloy conditions the mechanical flexibility of endodontic rotary files at body temperature.Two different rotary instruments, a Profile GT 20/.06 and a Profile GT Series X 20/.06, were selected due to their geometrical similarity and their different constituent alloy. GT series X files are made from M-Wire, a Ni-Ti alloy allegedly having higher flexibility at body temperature. Both files were analysed by X-Ray Diffraction and Differential Scanning Calorimetry to investigate phase transformations and the effects of working temperature on these different alloys. Mechanical behaviour was assessed by means of static bending and torsional Finite Element simulations, taking into account the nonlinear superelastic behaviour of Ni-Ti materials. It was found that GT files present austenitic phase at body temperature, whereas GT series X present R-phase at temperatures under 40 °C with a potential for larger flexibility. For the same load conditions, simulations showed that the slight geometrical differences between the two files do not introduce great disagreement in the instruments' mechanical response. It was confirmed that M-Wire increases the instrument's flexibility, mainly due to the presence of R-phase at body temperature.

  4. Untying Our Hands: Reconsidering Cyber as a Separate Instrument of National Power

    DTIC Science & Technology

    2017-04-21

    to the level of an instrument of national power operating alongside the military, diplomatic, economic , and informational instruments of national...Reveron (Washington DC: Georgetown University Press, 2012), 178-182. 26 informational, military, and economic capabilities (also known by its...outcome.”41 Writing over seventy years ago, E. H. Carr provided a useful deconstruction of political power into military power, economic power, and

  5. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments.

    PubMed

    Shen, Ya; Zhou, Hui-min; Zheng, Yu-feng; Peng, Bin; Haapasalo, Markus

    2013-02-01

    The performance and mechanical properties of nickel-titanium (NiTi) instruments are influenced by factors such as cross-section, flute design, raw material, and manufacturing processes. Many improvements have been proposed by manufacturers during the past decade to provide clinicians with safer and more efficient instruments. The mechanical performance of NiTi alloys is sensitive to their microstructure and associated thermomechanical treatment history. Heat treatment or thermal processing is one of the most fundamental approaches toward adjusting the transition temperature in NiTi alloy, which affects the fatigue resistance of NiTi endodontic files. The newly developed NiTi instruments made from controlled memory wire, M-Wire (Dentsply Tulsa Dental Specialties, Tulsa, OK), or R-phase wire represent the next generation of NiTi alloys with improved flexibility and fatigue resistance. The advantages of NiTi files for canal cleaning and shaping are decreased canal transportation and ledging, a reduced risk of file fracture, and faster and more efficient instrumentation. The clinician must understand the nature of different NiTi raw materials and their impact on instrument performance because many new instruments are introduced on a regular basis. This review summarizes the metallurgical properties of next-generation NiTi instruments, the impact of thermomechanical treatment on instrument flexibility, and the resistance to cyclic fatigue and torsion. The aim of this review was to provide clinicians with the knowledge necessary for evidence-based practices, maximizing the benefits from the selection and application of NiTi rotary instruments for root canal treatment. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments.

    PubMed

    Pereira, E S J; Peixoto, I F C; Viana, A C D; Oliveira, I I; Gonzalez, B M; Buono, V T L; Bahia, M G A

    2012-05-01

    To compare physical and mechanical properties of one conventional and one thermomechanically treated nickel-titanium (NiTi) wire used to manufacture rotary endodontic instruments. Two NiTi wires 1.0 mm in diameter were characterized; one of them, C-wire (CW), was processed in the conventional manner, and the other, termed M-Wire (MW), received an additional heat treatment according to the manufacturer. Chemical composition was determined by energy-dispersive X-ray spectroscopy, phase constitution by XRD and the transformation temperatures by DSC. Tensile loading/unloading tests and Vickers microhardness measurements were performed to assess the mechanical behaviour. Data were analysed using analysis of variance (α = 0.05). The two wires showed approximately the same chemical composition, close to the 1 : 1 atomic ratio, and the β-phase was the predominant phase present. B19' martensite and the R-phase were found in MW, in agreement with the higher transformation temperatures found in this wire compared with CW, whose transformation temperatures were below room temperature. Average Vickers microhardness values were similar for MW and CW (P = 0.91). The stress at the transformation plateau in the tensile load-unload curves was lower and more uniform in the M-Wire, which also showed the smallest stress hysteresis and apparent elastic modulus. The M-Wire had physical and mechanical properties that can render endodontic instruments more flexible and fatigue resistant than those made with conventionally processed NiTi wires. © 2011 International Endodontic Journal.

  7. Effect of finishing instrumentation using NiTi hand files on volume, surface area and uninstrumented surfaces in C-shaped root canal systems.

    PubMed

    Amoroso-Silva, P; Alcalde, M P; Hungaro Duarte, M A; De-Deus, G; Ordinola-Zapata, R; Freire, L G; Cavenago, B C; De Moraes, I G

    2017-06-01

    To assess the effect of 90°-oscillatory instrumentation with hand files on several morphological parameters (volume, surface area and uninstrumented surface) in C-shaped root canals after instrumentation using a single-file reciprocation system (Reciproc; VDW, Munich, Germany) and a Self-Adjusting File System (SAF; ReDent Nova, Ra'anana, Israel). Twenty mandibular second molars with C-shaped canals and C1 canal configurations were divided into two groups (n = 10) and instrumented with Reciproc and SAF instruments. A size 30 NiTi hand K-file attached to a 90°-oscillatory motion handpiece was used as final instrumentation in both groups. The specimens were scanned using micro-computed tomography after all procedures. Volume, surface area increase and uninstrumented root canal surface were analysed using CTAn software (Bruker-microCT, Kontich, Belgium). Also, the uninstrumented root canal surface was calculated for each canal third. All values were compared between groups using the Mann-Whitney test and within groups using the Wilcoxon's signed-rank test. Instrumentation with Reciproc significantly increased canal volume compared with instrumentation with SAF. Additionally, the canal volumes were significantly increased after 90°-oscillatory instrumentation (between and within group comparison; (P < 0.05)). Regarding the increase in surface area after all instrumentation protocols, statistical analysis only revealed significant differences in the within groups comparison (P < 0.05). Reciproc and SAF instrumentation yielded an uninstrumented root canal surface of 28% and 34%, respectively, which was not significantly different (P > 0.05). Final oscillatory instrumentation significantly reduced the uninstrumented root canal surface from 28% to 9% (Reciproc) and from 34% to 15% (SAF; P < 0.05). The apical and middle thirds exhibited larger uninstrumented root canal surfaces after the first instrumentation that was significantly reduced after oscillatory

  8. Fatigue testing of controlled memory wire nickel-titanium rotary instruments.

    PubMed

    Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus

    2011-07-01

    To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys to manufacture NiTi files and developed new manufacturing processes. This study was aimed to examine the fatigue behavior of NiTi instruments from a novel controlled memory NiTi wire (CM Wire). Instruments of ProFile, Typhoon (TYP), Typhoon CM (TYP CM), DS-SS0250425NEYY (NEYY), and DS-SS0250425NEYY CM (NEYY CM) (DS Dental, Johnson City, TN) all size 25/.04 were subjected to rotational bending at the curvature of 35° and 45° in air at the temperature of 23° ± 2°C, and the number of revolutions to fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites, the percentage of dimple area to the whole fracture cross-section, and the surface strain amplitude (ε(a)) were noted. The new alloy yielded an improvement of over three to eight times in N(f) of CM files than that of conventional NiTi files (P < .05). The vast majority of CM instruments (50%-92%) showed multiple crack origins, whereas most instruments made from conventional NiTi wire (58%-100%) had one crack origin. The values of the fraction area occupied by the dimple region were significantly smaller on CM NiTi instruments compared with conventional NiTi instruments (P < .01). The square (NEYY CM) versus the triangular (TYP CM) configuration showed a significantly different lifetime on CM wire at both curvatures (P < .01). The material property had a substantial impact on fatigue lifetime. Instruments made from CM Wire had a significantly higher N(f) and lower surface strain amplitude than the conventional NiTi wire files with identical design. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. A Comparative Study on the Amount of Extruded Material from the Apical Foramen with NiTi Rotary and Stainless Steel Hand Instruments

    PubMed Central

    Nazari, Shahrzad; MirMotalebi, Farshid

    2006-01-01

    INTRODUCTION: The purpose of the present study was to quantify and compare the amount of extruded debris from apical foramen after instrumentation of the root canal system with hand and rotary instruments. MATERIALS AND METHODS: Root canals of forty five fresh extracted single rooted human teeth with mature apexes and less than 15 degree of root curvature were instrumented in group A with stainless steel K-Type files, in group B with rotary NiTi Flex Master files, and in group C with rotary NiTi ProTaper files and followed weighting the extruded debris by a digital scale to within 0.0001 gram accuracy. RESULTS: In all groups, the mean weight of extruded debris was not more than 5 mg (P=0.0l) and was ranked as: Group A>Group B>Group C. There were statistically significant differences among three groups (p=0.0l). The mean value of extruded debris in the ProTaper and Flex Master groups were 0.652 and 0.788 mg, respectively. CONCLUSION: The study revealed that the amount of extruded debris from the apical foramen was minimal when ProTaper files were used. PMID:24470804

  10. Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments.

    PubMed

    Capar, Ismail Davut; Ertas, Huseyin; Arslan, Hakan

    2015-04-01

    New files (ProTaper Next/HyFlex/OneShape) are made from novel nickel-titanium (NiTi) alloys/treatments. The purpose of this study was to compare the cyclic fatigue resistance of these new instruments with that of Revo-S instruments. Four groups of 20 NiTi endodontic instruments were tested in steel canals with a 3 mm radius and a 60° angle of curvature. The cyclic fatigue of the following NiTi instruments with a tip size 25 and 0.06 taper that were manufactured with different alloys was tested: ProTaper Next X2 (M-Wire), OneShape (conventional NiTi), Revo-S Shaping Universal (conventional NiTi) and HyFlex 25/0.6 (controlled memory NiTi wire). A one-way anova and post-hoc Tukey's test (α = 0.05) revealed that the HyFlex files had the highest fatigue resistance and the Revo-S had the least fatigue resistance among the groups (P < 0.001). © 2014 Australian Society of Endodontology.

  11. Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments.

    PubMed

    Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus

    2012-03-01

    This study examined the fatigue behavior of 2 types of nickel-titanium (NiTi) instruments made from a novel controlled memory NiTi wire (CM wire) under various environment conditions. Three conventional superelastic NiTi instruments of ProFile (Dentsply Maillefer, Ballaigues, Switzerland), Typhoon (Clinician's Choice Dental Products, New Milford, CT), and DS-SS0250425NEYY (Clinician's Choice Dental Products) and 2 new CM wire instruments of Typhoon CM and DS-SS0250425NEYY CM were subjected to rotational bending at the curvature of 35° in air, deionized water, 17% EDTA, or deionized water after immersion in 6% sodium hypochlorite for 25 minutes, and the number of revolutions of fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites and the percentage of dimple area to the whole fracture cross-section were noted. Two new CM Wire instruments yielded an improvement of >4 to 9 times in N(f) than conventional NiTi files with the same design under various environments (P < .05). The fatigue life of 3 conventional superelastic NiTi instruments was similar under various environments, whereas the N(f) of 2 new CM Wire instruments was significantly longer in liquid media than in air (P < .05). The vast majority of CM instruments showed multiple crack origins, whereas most instruments made from conventional NiTi wire had one crack origin. The values of the area fraction occupied by the dimple region were significantly smaller on CM NiTi instruments than in conventional NiTi instruments under various environments (P < .05). Within the limitations of this study, the type of NiTi metal alloy (CM files vs conventional superelastic NiTi files) influences the cyclic fatigue resistance under various environments. The fatigue life of CM instruments is longer in liquid media than in air. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Mechanical and Metallurgical Properties of Various Nickel-Titanium Rotary Instruments

    PubMed Central

    Shim, Kyu-Sang; Oh, Soram; Kim, Yu-Chan; Jee, Kwang-Koo

    2017-01-01

    The aim of this study was to investigate the effect of thermomechanical treatment on mechanical and metallurgical properties of nickel-titanium (NiTi) rotary instruments. Eight kinds of NiTi rotary instruments with sizes of ISO #25 were selected: ProFile, K3, and One Shape for the conventional alloy; ProTaper NEXT, Reciproc, and WaveOne for the M-wire alloy; HyFlex CM for the controlled memory- (CM-) wire; and TF for the R-phase alloy. Torsional fracture and cyclic fatigue fracture tests were performed. Products underwent a differential scanning calorimetry (DSC) analysis. The CM-wire and R-phase groups had the lowest elastic modulus, followed by the M-wire group. The maximum torque of the M-wire instrument was comparable to that of a conventional instrument, while those of the CM-wire and R-phase instruments were lower. The angular displacement at failure (ADF) for the CM-wire and R-phase instruments was higher than that of conventional instruments, and ADF of the M-wire instruments was lower. The cyclic fatigue resistance of the thermomechanically treated NiTi instruments was higher. DSC plots revealed that NiTi instruments made with the conventional alloy were primarily composed of austenite at room temperature; stable martensite and R-phase were found in thermomechanically treated instruments. PMID:29318149

  13. Cutting efficiency of four different rotary nickel: Titanium instruments

    PubMed Central

    Cecchin, Doglas; de Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma; Gariba-Silva, Ricardo

    2011-01-01

    Aim: The aim of this study was to evaluate the cutting efficiency of rotary nickel-titanium (NiTi) instruments K3, NiTi Tee, Profile, and Quantec with taper size 04/25. Materials and Methods: The number of samples was 10 for each group (n = 10). The cutting efficiency was measured by the mass loss from each acrylic resin block after instrumentation of a simulated canal using the Crown-down technique. Results: The analysis of variance (ANOVA) showed that there was a statistically significant difference among the studied groups. The Tukey's test showed that the acrylic resin blocks prepared with instruments K3 (0.00369 ± 0.00022), NiTi Tee (0.00368 ± 0.00023), and Profile (0.00351 ± 0.00026) presented the greatest mass loss, showing no statistically significant difference among them (P < 0.05). The lowest mass loss was found in the blocks prepared with Quantec instruments (0.00311 ± 0.0003) (P < 0.05). Conclusions: It could be concluded that the K3, NiTi Tee, and Profile instruments presented a greater cutting efficiency than the Quantec instruments. PMID:21814349

  14. A comparative evaluation of two rotary Ni-Ti instruments in the removal of gutta-percha during retreatment.

    PubMed

    Preetam, C S; Chandrashekhar, M; Gunaranjan, T; Kumar, S Kishore; Miskeen Sahib, S A; Kumar, M Senthil

    2016-08-01

    The purpose of this study is to achieve an effective method to remove root canal filling material from the root canal system. The study, thus, aims to evaluate the efficacy of the cleaning ability of two different rotary Ni-Ti systems; ProTaper Retreatment files and RaCe System compared to hand instrumentation with Hedstrom files for the removal of gutta-percha during retreatment. Thirty mandibular premolars with one single straight canal were decoronated and instrumented with ProTaper files and filled with thermoplastic gutta-percha. After 30 days, the samples were divided into three groups and gutta-percha was removed with the test instruments. The postoperative radiographs were evaluated with known criteria by dividing the root into cervical third, middle third, and apical third. The results were tabulated and Statistical Package for Social Sciences Software (IBM Corporation) was used for analysis. The mean deviation of the results were first calculated and then t-test and analysis of variance test (two-tailed P value) were evaluated for establishing significant differences. The rotary instruments were effective in removing the gutta-percha from the canals. Therefore, significant difference was observed between the efficacies of the two rotary systems used. The rotary instruments showed effective gutta-percha removal in the cervical and middle one third. (P > 0.05). However, apical debridement was effective with Hedstrom files. The study concluded the use of both rotary and hand instrumentation for effective removal of gutta-percha for retreatment.

  15. Biocompatibility study of plasma-coated nitinol (NiTi alloy) stents.

    PubMed

    Wang, G; Shen, Y; Cao, Y; Yu, Q; Guidoin, R

    2007-12-01

    The authors aimed to assess the surface modification effects of plasma coatings on biocompatibility of nitinol intravascular stent in terms of anticoagulation, haemocytolysis rate, hydrophilicity, cytotoxicity and so on. In order to improve their surface adhesive properties to endothelial cells, NiTi alloy intravascular stents were treated and coated using a low-temperature plasma deposition technique. It was found that plasma coating changed the surface morphology of the stents to a micron-level surface roughness in the range of 1-5 microm. In comparison with the untreated control, the plasma-treated NiTi alloy intravascular stents showed increased surface hydrophilicity and enhanced anticoagulation property. Testing results on plasma-coated NiTi stents indicated that they complied with the standard of national biologic safety evaluation of medical apparatus and instrument (GB/T16886-1997, People's Republic of China) in terms of haemocytolysis rate, cytotoxicity and pyretogen.

  16. The instrument for investigating magnetic fields of isochronous cyclotrons

    NASA Astrophysics Data System (ADS)

    Avreline, N. V.

    2017-12-01

    A new instrument was designed and implemented in order to increase the measurement accuracy of magnetic field maps for isochronous Cyclotrons manufactured by Advanced Cyclotron Systems Inc. This instrument uses the Hall Probe (HP) from New Zealand manufacturer Group3. The specific probe used is MPT-141 HP and can measure magnetic field in the range from 2G to 21kG. Use of a fast ADC NI9239 module and error reduction algorithms, based on a polynomial regression method, allowed to reduce the noise to 0.2G. The design of this instrument allows to measure high gradient magnetic fields, as the resolution of the HP arm angle is within 0.0005° and the radial position resolution is within 25μm. A set of National Instrument interfaces connected to a desktop computer through a network are used as base control and data acquisition systems.

  17. Study on bending behaviour of nickel–titanium rotary endodontic instruments by analytical and numerical analyses

    PubMed Central

    Tsao, C C; Liou, J U; Wen, P H; Peng, C C; Liu, T S

    2013-01-01

    Aim To develop analytical models and analyse the stress distribution and flexibility of nickel–titanium (NiTi) instruments subject to bending forces. Methodology The analytical method was used to analyse the behaviours of NiTi instruments under bending forces. Two NiTi instruments (RaCe and Mani NRT) with different cross-sections and geometries were considered. Analytical results were derived using Euler–Bernoulli nonlinear differential equations that took into account the screw pitch variation of these NiTi instruments. In addition, the nonlinear deformation analysis based on the analytical model and the finite element nonlinear analysis was carried out. Numerical results are obtained by carrying out a finite element method. Results According to analytical results, the maximum curvature of the instrument occurs near the instrument tip. Results of the finite element analysis revealed that the position of maximum von Mises stress was near the instrument tip. Therefore, the proposed analytical model can be used to predict the position of maximum curvature in the instrument where fracture may occur. Finally, results of analytical and numerical models were compatible. Conclusion The proposed analytical model was validated by numerical results in analysing bending deformation of NiTi instruments. The analytical model is useful in the design and analysis of instruments. The proposed theoretical model is effective in studying the flexibility of NiTi instruments. Compared with the finite element method, the analytical model can deal conveniently and effectively with the subject of bending behaviour of rotary NiTi endodontic instruments. PMID:23173762

  18. Application of fiber Bragg grating sensors in monitoring fatigue failure of NiTi rotary endodontic instruments

    NASA Astrophysics Data System (ADS)

    Liu, C. Y.; Shin, C. S.

    2012-04-01

    NiTi endodontic rotary instruments subjected to alternating tension and compression stress in root canals may fracture without prior warning. Once broken, extracting the fractured part from the canal is a difficult job and is annoying to both the patient and the dentist. Warning of an imminent fracture during clinical use will be a great help to avoid medical and legal complications. A monitoring system employing Fiber Bragg Grating (FBG) sensors has been attempted. The reason of using FBG is its small size which is very promising in integrating with the handpiece of the endodontic equipment. When cracking developed in an rotary instrument, we expect the natural vibration frequency of the instrument changes. If we can pick up the stress wave transmitted through the structural components of the rotary instruments, we may be able to detect the occurrence of a crack. In the current work, we found that we can successfully locate the operation period in the time domain by picking up and analyzing the sound wave using FBG. Furthermore, by employing Fast Fourier Transform (FFT) on the signal, we can reveal the energy variation and the frequency shifting phenomenon in specific section of frequency domain. For some characteristic frequencies, it was found that the energy and frequency varied in a well-defined pattern during the period of crack growth. It is hoped that with these information, the fatigue failure of rotary instruments can be closely monitored to avoid/alleviate the occurrence of unexpected fracture during clinical use.

  19. Application of fiber Bragg grating sensors in monitoring fatigue failure of NiTi rotary endodontic instruments

    NASA Astrophysics Data System (ADS)

    Liu, C. Y.; Shin, C. S.

    2011-11-01

    NiTi endodontic rotary instruments subjected to alternating tension and compression stress in root canals may fracture without prior warning. Once broken, extracting the fractured part from the canal is a difficult job and is annoying to both the patient and the dentist. Warning of an imminent fracture during clinical use will be a great help to avoid medical and legal complications. A monitoring system employing Fiber Bragg Grating (FBG) sensors has been attempted. The reason of using FBG is its small size which is very promising in integrating with the handpiece of the endodontic equipment. When cracking developed in an rotary instrument, we expect the natural vibration frequency of the instrument changes. If we can pick up the stress wave transmitted through the structural components of the rotary instruments, we may be able to detect the occurrence of a crack. In the current work, we found that we can successfully locate the operation period in the time domain by picking up and analyzing the sound wave using FBG. Furthermore, by employing Fast Fourier Transform (FFT) on the signal, we can reveal the energy variation and the frequency shifting phenomenon in specific section of frequency domain. For some characteristic frequencies, it was found that the energy and frequency varied in a well-defined pattern during the period of crack growth. It is hoped that with these information, the fatigue failure of rotary instruments can be closely monitored to avoid/alleviate the occurrence of unexpected fracture during clinical use.

  20. Reduction in bacterial counts in infected root canals after rotary or hand nickel-titanium instrumentation--a clinical study.

    PubMed

    Rôças, I N; Lima, K C; Siqueira, J F

    2013-07-01

    To compare the antibacterial efficacy of two instrumentation techniques, one using hand nickel-titanium (NiTi) instruments and the other using rotary NiTi instruments, in root canals of teeth with apical periodontitis. Root canals from single-rooted teeth were instrumented using either hand NiTi instruments in the alternated rotation motion technique or rotary BioRaCe instruments. The irrigant used in both groups was 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis by real-time polymerase chain reaction (qPCR). Qualitative analysis was also performed using presence/absence data from culture and qPCR assays. Bacteria were detected in all S1 samples by both methods. In culture analysis, 45% and 35% of the canals were still positive for bacterial presence after hand and rotary NiTi instrumentation, respectively (P > 0.05). Rotary NiTi instrumentation resulted in significantly fewer qPCR-positive cases (60%) than hand NiTi instrumentation (95%) (P = 0.01). Intergroup comparison of quantitative data showed no significant difference between the two techniques. There was no significant difference in bacterial reduction in infected canals after instrumentation using hand or rotary NiTi instruments. In terms of incidence of positive results for bacteria, culture also showed no significant differences between the groups, but the rotary NiTi instrumentation resulted in more negative results in the more sensitive qPCR analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  1. A comparative evaluation of two rotary Ni-Ti instruments in the removal of gutta-percha during retreatment

    PubMed Central

    Preetam, C. S.; Chandrashekhar, M.; Gunaranjan, T.; Kumar, S. Kishore; Miskeen Sahib, S. A.; Kumar, M. Senthil

    2016-01-01

    Aim: The purpose of this study is to achieve an effective method to remove root canal filling material from the root canal system. The study, thus, aims to evaluate the efficacy of the cleaning ability of two different rotary Ni-Ti systems; ProTaper Retreatment files and RaCe System compared to hand instrumentation with Hedstrom files for the removal of gutta-percha during retreatment. Materials and Methods: Thirty mandibular premolars with one single straight canal were decoronated and instrumented with ProTaper files and filled with thermoplastic gutta-percha. After 30 days, the samples were divided into three groups and gutta-percha was removed with the test instruments. The postoperative radiographs were evaluated with known criteria by dividing the root into cervical third, middle third, and apical third. The results were tabulated and Statistical Package for Social Sciences Software (IBM Corporation) was used for analysis. Results: The mean deviation of the results were first calculated and then t-test and analysis of variance test (two-tailed P value) were evaluated for establishing significant differences. The rotary instruments were effective in removing the gutta-percha from the canals. Therefore, significant difference was observed between the efficacies of the two rotary systems used. The rotary instruments showed effective gutta-percha removal in the cervical and middle one third. (P > 0.05). However, apical debridement was effective with Hedstrom files. Conclusion: The study concluded the use of both rotary and hand instrumentation for effective removal of gutta-percha for retreatment. PMID:27652245

  2. The Lebanese Armed Forces Engaging Nahr Al-Bared Palestinian Refugee Camp Using the Instruments of National Power

    DTIC Science & Technology

    2017-06-09

    organization. Then, the study analyses the use of the Diplomatic, Informational, Military, and Economic instruments of national power (DIME) by the LAF in...Then, the study analyses the use of the Diplomatic, Informational, Military, and Economic instruments of national power (DIME) by the LAF in...56 Economic Element of National Power

  3. [Comparison of the shaping ability of three Ni-Ti rotary instruments in the preparation of simulated curved root canals].

    PubMed

    Qiu, Ning; Wang, Chu-yu; Liu, Yu-fei; Yu, Xiao-qing; Xue, Ming

    2016-04-01

    To compare the shaping ability of three rotary Ni-Ti instruments in simulated root canals. A total of 30 simulated resin blocks were divided randomly into 3 groups: ProTaper Universal, ProTaper Next and TF Adaptive. Each group consisted of 10 root canals. The preparation time and changes in canal curvature were measured. Pre- and post-instrumentation photograghs were taken by precise camera and superimposed through Photoshop. The material removed from the inner and outer canal walls at 9 points beginning at 0 mm from the foramen were measured with Image Pro Plus. Centering ability was determined accordingly. The data was analyzed with SPSS13.0 software package. During root canal preparation, no instruments fractured. ProTaper Next was much faster than ProTaper Universal(P<0.05). At the apical curvature, transportation was the least with TF Adaptive, followed by Protaper Next (P<0.05). There were no significant differences in 3 groups with respect to coronal curvature transportation (P>0.05). Under the conditions of this study, ProTaper Next was the most efficient instrument. TF Adaptive and Protaper Next showed better shaping ability. In general, all the instruments respected original canal curvature well and were safe to be used.

  4. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    PubMed

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  5. Instrument workstation for the EGSE of the Near Infrared Spectro-Photometer instrument (NISP) of the EUCLID mission

    NASA Astrophysics Data System (ADS)

    Trifoglio, M.; Gianotti, F.; Conforti, V.; Franceschi, E.; Stephen, J. B.; Bulgarelli, A.; Fioretti, V.; Maiorano, E.; Nicastro, L.; Valenziano, L.; Zoli, A.; Auricchio, N.; Balestra, A.; Bonino, D.; Bonoli, C.; Bortoletto, F.; Capobianco, V.; Chiarusi, T.; Corcione, L.; Debei, S.; De Rosa, A.; Dusini, S.; Fornari, F.; Giacomini, F.; Guizzo, G. P.; Ligori, S.; Margiotta, A.; Mauri, N.; Medinaceli, E.; Morgante, G.; Patrizii, L.; Sirignano, C.; Sirri, G.; Sortino, F.; Stanco, L.; Tenti, M.

    2016-07-01

    The NISP instrument on board the Euclid ESA mission will be developed and tested at different levels of integration using various test equipment which shall be designed and procured through a collaborative and coordinated effort. The NISP Instrument Workstation (NI-IWS) will be part of the EGSE configuration that will support the NISP AIV/AIT activities from the NISP Warm Electronics level up to the launch of Euclid. One workstation is required for the NISP EQM/AVM, and a second one for the NISP FM. Each workstation will follow the respective NISP model after delivery to ESA for Payload and Satellite AIV/AIT and launch. At these levels the NI-IWS shall be configured as part of the Payload EGSE, the System EGSE, and the Launch EGSE, respectively. After launch, the NI-IWS will be also re-used in the Euclid Ground Segment in order to support the Commissioning and Performance Verification (CPV) phase, and for troubleshooting purposes during the operational phase. The NI-IWS is mainly aimed at the local storage in a suitable format of the NISP instrument data and metadata, at local retrieval, processing and display of the stored data for on-line instrument assessment, and at the remote retrieval of the stored data for off-line analysis on other computers. We describe the design of the IWS software that will create a suitable interface to the external systems in each of the various configurations envisaged at the different levels, and provide the capabilities required to monitor and verify the instrument functionalities and performance throughout all phases of the NISP lifetime.

  6. Analysis of El Niño-Southern Oscillation Phenomena's Effect on the Gross Domestic Product of Western Pacific Nations

    NASA Astrophysics Data System (ADS)

    O'Connell, M.; Lewis, A.; Mezzafonte, D.

    2014-12-01

    El Niño Southern Oscillation (ENSO) is a climatological phenomenon that occurs in the tropical Pacific Ocean which has a direct influence on the climate of western Pacific nations. This study evaluated the meteorological effects of ENSO on the economies of Indonesia and the Philippines. It was hypothesized that decreased precipitation in the western Tropical Pacific region during El Niño events causes decreases in agricultural production in the region resulting in a negative effect on a nation's Gross Domestic Product (GDP). Furthermore, during La Niña events, when precipitation increases, an increase in the nation's agricultural GDP and overall GDP is expected. Annual GDP data were obtained from the World Bank and the Bank of Indonesia for 1960-2012. Sea surface temperatures (SST) data, in the Niño 3.4 region, were obtained from the National Oceanic and Atmospheric Administration (NOAA) National Climate Data Center. Data of the agricultural and total GDP of Indonesia and the Philippines had inconclusive correlations with ENSO signal data. By examining data between smaller time segments of the overall 1960-2012 timeframe, more conclusive results could not be discerned. Indonesia's quarterly non-oil GDP for 2000-2009 was independently correlated with ENSO providing better insight on the variables' relationship during discrete ENSO phenomena. The results provided strong correlation coefficients of 0.831 and 0.624 in support of the antithesis as well as -0.421 in support of the hypothesis. An economic anomaly known as the East Asian Financial Crisis may have been the cause of the unexpected correlations however more data is needed to be certain. Overall, the results demonstrated weak to moderate correlations between studied variables. However, more data is needed to reach substantial conclusions.

  7. Safety Assessment of Two Hybrid Instrumentation Techniques in a Dental Student Endodontic Clinic: A Retrospective Study.

    PubMed

    Coelho, Marcelo Santos; Card, Steven John; Tawil, Peter Zahi

    2017-03-01

    The aim of this study was to retrospectively assess the safety potential of a hybrid technique combining nickel-titanium (NiTi) reciprocating and rotary instruments by third- and fourth-year dental students in the predoctoral endodontics clinic at one U.S. dental school. For the study, 3,194 root canal treatments performed by 317 dental students from 2012 through 2015 were evaluated for incidence of ledge creation and instrument separation. The hybrid reciprocating and rotary technique (RRT) consisted of a glide path creation with stainless steel hand files up to size 15/02, a crown down preparation with a NiTi reciprocating instrument, and an apical preparation with NiTi rotary instruments. The control was a traditional rotary and hand technique (RHT) that consisted of the same glide path procedure followed by a crown down preparation with NiTi rotary instruments and an apical preparation with NiTi hand instruments. The results showed that the RHT technique presented a rate of ledge creation of 1.4% per root and the RRT technique was 0.5% per root (p<0.05). Three stainless steel hand files separated: two in the RHT group and one in the RRT group. There was no separation of any NiTi file in any of the techniques. The use of the reciprocating and rotary technique for root canal instrumentation by these dental students provided good safety. This hybrid technique offered a low rate of ledge creation along with no NiTi instrument separation.

  8. National Beef Quality Audit-2011: Survey of instrument grading assessments of beef carcass characteristics

    USDA-ARS?s Scientific Manuscript database

    The instrument grading assessments for the 2011 National Beef Quality Audit evaluated seasonal trends of beef carcass quality and yield attributes over the course of the year. One week of instrument grading data, HCW, gender, USDA quality grade (QG), and yield grade (YG) factors, were collected ever...

  9. Online Course Design in Higher Education: A Review of National and Statewide Evaluation Instruments

    ERIC Educational Resources Information Center

    Baldwin, Sally; Ching, Yu-Hui; Hsu, Yu-Chang

    2018-01-01

    This research identifies six online course evaluation instruments used nationally or in statewide systems. We examined the characteristics (i.e., number of standards and criteria) and coded the criteria that guide the design of online courses. We discussed the focus of the instruments and their unique features.

  10. Ni-Co laterite deposits

    USGS Publications Warehouse

    Marsh, Erin E.; Anderson, Eric D.

    2011-01-01

    Nickel-cobalt (Ni-Co) laterite deposits are an important source of nickel (Ni). Currently, there is a decline in magmatic Ni-bearing sulfide lode deposit resources. New efforts to develop an alternative source of Ni, particularly with improved metallurgy processes, make the Ni-Co laterites an important exploration target in anticipation of the future demand for Ni. This deposit model provides a general description of the geology and mineralogy of Ni-Co laterite deposits, and contains discussion of the influences of climate, geomorphology (relief), drainage, tectonism, structure, and protolith on the development of favorable weathering profiles. This model of Ni-Co laterite deposits represents part of the U.S. Geological Survey Mineral Resources Program's effort to update the existing models to be used for an upcoming national mineral resource assessment.

  11. Questionnaire survey on the use of rotary nickel-titanium endodontic instruments by Australian dentists.

    PubMed

    Parashos, P; Messer, H H

    2004-04-01

    To ascertain the extent of the adoption and use of rotary nickel-titanium (NiTi) instruments and techniques in general dental practice and specialist endodontic practice in Australia in 2001. A questionnaire survey comprising 43 questions was developed by first creating questions, then pilot testing with 10 postgraduate students in endodontics, followed by a final revision. The final series of questions covered demographics, patterns of rotary NiTi usage, issues associated with NiTi usage and training in NiTi use. The sampling frame was 908, comprising 64 endodontists and 844 general dentists. The overall response rate was 87%. Rotary NiTi instruments were used by 22% of general dentists and 64% of endodontists. The two main reasons for not using rotary NiTi were 'no perceived advantage' and 'too fragile'. Instrument fracture had been experienced by 74% of respondents, and 72% of these had fractured one to five files for the two main perceived reasons of 'excessive pressure on the file' and 'over-usage'. The next two most common problems encountered were 'binding' (53%) and 'ledging' (45%). Very high proportions of positive experiences were noted. Most respondents (73%) had attended one or more continuing education courses, most of which were provided by dental supply companies (64%). The results indicate a sensible and responsible approach to the incorporation of rotary NiTi instruments and techniques into root canal treatment. Dentists were aware of the limitations of the new technology, but were taking steps to become familiar with the properties and behaviour of the instruments. Instrument fracture was common, but it was of low frequency and did not deter dentists from using the technology.

  12. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India

    PubMed Central

    Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-01-01

    Introduction The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. Aim The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. Materials and Methods A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher’s-exact test and the Chi-Square test. Results Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. Conclusion A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced

  13. The efficacy of two rotary NiTi instruments and H-files to remove gutta-percha from root canals

    PubMed Central

    Akpınar, Kerem E.; Altunbaş, Demet

    2012-01-01

    Objective: The aim of this study was to evaluate the efficacy of R-Endo® and K3® rotary nickel-titanium instruments compared with manual instrumentation with H-files, with use of a solvent, for removal of gutta-percha during retreatment. Study design: Forty five freshly extracted human single-rooted teeth, each with one root canal, were instrumented with K-files and filled using cold lateral compaction of gutta-percha and AH 26® sealer. The teeth were randomly divided into three groups of 15 specimens each. Removal of gutta-percha was performed with the following devices and techniques: Group 1 (H-files), Group 2 (R-Endo®), and Group 3 (K3®). The specimens were rendered transparent for the evaluation of the area of remaining gutta-percha/sealer in buccolingual and mesiodistal directions. Statistical analysis as performed by using one-way ANOVA and Kruskal-Wallis tests (p=0.05). Results: All retreatment techniques used in this study left some filling material inside the root canal. Images in buccolingual and mesiodistal directions showed no significant differences between the groups (p>0.05). Conclusions: Under the experimental conditions, the remaining filling material after retreatment was similar for each group. Key words:Gutta-percha removal, K3®, NiTi, R-Endo®. PMID:22143729

  14. Moral and Instrumental Rationales for Affirmative Action in Five National Contexts

    ERIC Educational Resources Information Center

    Moses, Michele S.

    2010-01-01

    The author's primary aims are to clarify the differing rationales for affirmative action that have emerged in five nations--France, India, South Africa, the United States, and Brazil--and to make the case for the most compelling rationales, whether instrumentally or morally based. She examines the different social contexts surrounding the…

  15. Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

    PubMed

    Ajuz, Natasha C C; Armada, Luciana; Gonçalves, Lucio S; Debelian, Gilberto; Siqueira, José F

    2013-04-01

    This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P < .05), except for PathFiles at the 0-mm level. ScoutRaCe instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P < .05). Findings suggest that rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Comparative study of root-canal shaping with stainless steel and rotary NiTi files performed by preclinical dental students.

    PubMed

    Alrahabi, Mothanna

    2015-01-01

    We evaluated the use of NiTi rotary and stainless steel endodontic instruments for canal shaping by undergraduate students. We also assessed the quality of root canal preparation as well as the occurrence of iatrogenic events during instrumentation. In total, 30 third-year dental students attending Taibah University Dental College prepared 180 simulated canals in resin blocks with NiTi rotary instruments and stainless steel hand files. Superimposed images were prepared to measure the removal of material at different levels from apical termination using the GSA image analysis software. Preparation time, procedural accidents, and canal shape after preparation were analyzed using χ 2 and t-tests. The statistical significance level was set at P < 0.05. There were significant differences in preparation time between NiTi instruments and stainless steel files; the former was associated with shorter preparation time, less ledge formation (1.1% vs. 14.4%), and greater instrument fracture (5.56% vs. 1.1%). These results indicate that NiTi rotary instruments result in better canal geometry and cause less canal transportation. Manual instrumentation using stainless steel files is safer than rotary instrumentation for inexperienced students. Intensive preclinical training is a prerequisite for using NiTi rotary instruments. These results prompted us to reconsider theoretical and practical coursework when teaching endodontics.

  17. Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis

    PubMed Central

    Santos, Leandro de Arruda; Resende, Pedro Damas; Bahia, Maria Guiomar de Azevedo; Buono, Vicente Tadeu Lopes

    2016-01-01

    The effects of the presence of the R-phase in a near-equiatomic NiTi alloy on the mechanical responses of an endodontic instrument were studied by using finite element analysis. The input data for the constitutive model in the simulation were obtained by tensile testing of three NiTi wires: superelastic austenite NiTi, austenite + R-phase NiTi, and fully R-phased NiTi. The wires were also characterized by X-ray diffraction and differential scanning calorimetry. A commercially available endodontic instrument was scanned using microcomputed tomography, and the resulting images were used to build the geometrical model. The numerical analyses were performed in ABAQUS using load and boundary conditions based on the ISO 3630-1 specification for the bending and torsion of endodontic instruments. The modeled instrument containing only R-phase demanded the lowest moment to be bent, followed by the one with mixed austenite + R-phase. The superelastic instrument, containing essentially austenite, required the highest bending moment. During bending, the fully R-phased instrument reached the lowest stress values; however, it also experienced the highest angular deflection when subjected to torsion. In summary, this simulation showed that NiTi endodontic instruments containing only R-phase in their microstructure would show higher flexibility without compromising their performance under torsion. PMID:27314059

  18. [The effect of instrumentation on original apical foramen shape using steel vs niti rotatory: computerized analysis].

    PubMed

    Gallina, G; Cumbo, E; Gallo, P; Pizzo, G; D'Angelo, M

    2002-01-01

    A fundamental requirement to obtain a correct endodontic preparation depends on the respect, during cleaning and shaping, of the original morphology of the apical foramen, (AF), so that the filling material will form a complete seal. In our previous studies, in order to verify if this presumption was respected using rotary NiTi instruments with cutting tip, we instrumented extracted teeth characterised by a different degree of root curvatures. Using a standardized system to replace the sample, the original shape of the apical foramen of each tooth was recorded using a computerised technique and then compared to the shape after instrumentation. The data showed differences on AF shapes depending on the degree of root canal curvatures. In fact, the teeth with straight canals showed the least alterations on the original AF shape; on the contrary, the teeth with curved canals showed apical foramen enlargement or transportation. Therefore, in the current study we aimed to compare the in vitro effects of stainless steel, (Flexofile, Dentsply Maillefer, Baillaigues, Switzerland), vs NiTi safe cutting tip (Quantec SC, (Tycom Dental, Irvine CA, U:S.A.), vs NiTi non cutting tip, (Quantec LX, Tycom Dental, Irvine CA, U:S.A.), instrumentation on original apical foramen shape. We used NiTi instruments according to standard technique suggested by Tycom, and hand steel files, to instrument the apical third, according to the Crown-Down technique. Working length was fixed at -0.5 from AF. Our results suggested that in the presence of accentuated canal curves rotary Niti, with cutting tip, cause significantly more enlargement of the AF area. At the same time, we also observed that NiTi rotary files, with both cutting and non-cutting tip, cause eccentric enlargement of AF in curved canals. Therefore, NiTi engine-driven instruments should be used carefully in the presence of accentuated canal curves to avoid enlargement or transportation of AF, probably because rotary NiTi files may

  19. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment.

    PubMed

    Inan, Ugur; Aydin, Cumhur

    2012-01-01

    A number of rotary nickel-titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system, and recently, rotary NiTi systems designed for root canal retreatment have been introduced. Because the main problem with the rotary NiTi files is fracture, the aim of this study was to compare the cyclic fatigue resistance of 3 different rotary NiTi systems designed for root canal retreatment. Total of 60 instruments of 3 different rotary NiTi systems designed for root canal retreatment were used in this study. Twenty R-Endo R3, 20 ProTaper D3, and 20 Mtwo R (Retreatment) 25.05 instruments were tested. Cyclic fatigue testing of instruments was performed by using a device that allowed the instruments to rotate freely inside an artificial canal. Each instrument was rotated until fracture occurred, and the number of cycles to fracture for each instrument was calculated. Representative samples were also evaluated under a scanning electron microscope to confirm the fracture was flexural. Data were analyzed by using 1-way analysis of variance test. R-Endo R3 instruments showed better cyclic fatigue resistance than ProTaper D3 and Mtwo R 25.05 instruments, and the difference was statistically significant (P < .05). There was no significant difference between ProTaper D3 and Mtwo R 25.05 groups. The R-Endo R3 instruments were more resistant to fatigue failure than ProTaper D3 and Mtwo R 25.05. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.

    PubMed

    Alapati, Satish B; Brantley, William A; Iijima, Masahiro; Clark, William A T; Kovarik, Libor; Buie, Caesar; Liu, Jie; Ben Johnson, William

    2009-11-01

    A novel thermomechanical processing procedure has been developed that yields a superelastic (SE) nickel-titanium (NiTi) wire (M-Wire) that laboratory testing shows has improved mechanical properties compared with conventional SE austenitic NiTi wires used for manufacture of rotary instruments. The objective of this study was to determine the origin of the improved mechanical properties. Specimens from 2 batches of M-Wire prepared under different processing conditions and from 1 batch of standard-processed SE wire for rotary instruments were examined by scanning transmission electron microscopy, temperature-modulated differential scanning calorimetry, micro-x-ray diffraction, and scanning electron microscopy with x-ray energy-dispersive spectrometric analyses. The processing for M-Wire yields a microstructure containing martensite, that the proportions of NiTi phases depend on processing conditions, and that the microstructure exhibits pronounced evidence of alloy strengthening. The presence of Ti(2)Ni precipitates in both microstructures indicates that M-Wire and the conventional SE wire for rotary instruments are titanium-rich.

  1. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use.

    PubMed

    Gambarini, G

    2001-07-01

    The purpose of the present study was to evaluate resistance to cyclic fatigue of new and used ProFile Ni-Ti rotary instruments. Used instruments were operated in 10 clinical cases using passive instrumentation and a crown-down preparation technique. Cyclic fatigue testing of new and used engine-driven instruments was then performed with a specific device which allowed the instruments to rotate freely inside a stainless steel artificial canal, whilst maintaining conditions close to the clinical situation. Instruments were rotated until fracture occurred and time to fracture was visually recorded with a chronometer. A significant reduction of rotation time to breakage (life span) was noted between new and used instruments. In all sizes new instruments were significantly more resistant than used ones (two-sample t-test, P < 0.01). No instrument underwent intracanal failure during clinical use. Prolonged clinical use of Ni-Ti engine-driven instruments significantly reduced their cyclic fatigue resistance. Nevertheless, each rotary instrument was successfully operated in up to 10 clinical cases without any intracanal failure.

  2. The suite of small-angle neutron scattering instruments at Oak Ridge National Laboratory

    DOE PAGES

    Heller, William T.; Cuneo, Matthew J.; Debeer-Schmitt, Lisa M.; ...

    2018-02-21

    Oak Ridge National Laboratory is home to the High Flux Isotope Reactor (HFIR), a high-flux research reactor, and the Spallation Neutron Source (SNS), the world's most intense source of pulsed neutron beams. The unique co-localization of these two sources provided an opportunity to develop a suite of complementary small-angle neutron scattering instruments for studies of large-scale structures: the GP-SANS and Bio-SANS instruments at the HFIR and the EQ-SANS and TOF-USANS instruments at the SNS. This article provides an overview of the capabilities of the suite of instruments, with specific emphasis on how they complement each other. As a result, amore » description of the plans for future developments including greater integration of the suite into a single point of entry for neutron scattering studies of large-scale structures is also provided.« less

  3. The suite of small-angle neutron scattering instruments at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heller, William T.; Cuneo, Matthew J.; Debeer-Schmitt, Lisa M.

    Oak Ridge National Laboratory is home to the High Flux Isotope Reactor (HFIR), a high-flux research reactor, and the Spallation Neutron Source (SNS), the world's most intense source of pulsed neutron beams. The unique co-localization of these two sources provided an opportunity to develop a suite of complementary small-angle neutron scattering instruments for studies of large-scale structures: the GP-SANS and Bio-SANS instruments at the HFIR and the EQ-SANS and TOF-USANS instruments at the SNS. This article provides an overview of the capabilities of the suite of instruments, with specific emphasis on how they complement each other. As a result, amore » description of the plans for future developments including greater integration of the suite into a single point of entry for neutron scattering studies of large-scale structures is also provided.« less

  4. Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use.

    PubMed

    Inan, Ugur; Gonulol, Nihan

    2009-10-01

    In recent years, a number of rotary nickel titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system. Although the NiTi instruments are more flexible than the stainless steel files, the main problem with the rotary NiTi instruments is the failure of the instruments. The aim of this study was to evaluate the deformation and fracture rate of Mtwo rotary nickel-titanium instruments (VDW, Munich, Germany) discarded after routine clinical use. A total of 593 Mtwo rotary NiTi instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, and then all the files were evaluated under a stereomicroscope for defects such as unwinding, curving, or bending and fracture. The fracture faces of separated files were also evaluated under a scanning electron microscope. The data were analyzed using a chi-square and z test. A percentage of all files (25.80%) showed defects, and the major defect was fracture (16.02%). The most frequently fractured file was #10.04 (30.39%). Deformations without fracture were mostly observed on #15.05 files (25.47%). A higher rate of deformation was observed for #10.04 and #15.05 files. Therefore, these files should be considered as single-use instruments. Because cyclic fatigue was the cause of 71.58% of the instrument fractures, it is also important not to exceed the maximum number of usage recommended by the manufacturer and discard the instruments on a regular basis.

  5. Perspective on the National Aero-Space Plane Program instrumentation development

    NASA Technical Reports Server (NTRS)

    Bogue, Rodney K.; Erbland, Peter

    1993-01-01

    A review of the requirement for, and development of, advanced measurement technology for the National Aerospace Plane program is presented. The objective is to discuss the technical need and the program commitment required to ensure that adequate and timely measurement capabilities are provided for ground and flight testing in the NASP program. The scope of the measurement problem is presented, the measurement process is described, how instrumentation technology development has been affected by NASP program evolution is examined, the national effort to define measurement requirements and assess the adequacy of current technology to support the NASP program is discussed, and the measurement requirements are summarized. The unique features of the NASP program that complicate the understanding of requirements and the development of viable solutions are illustrated.

  6. Finite Element Study on Continuous Rotating versus Reciprocating Nickel-Titanium Instruments.

    PubMed

    El-Anwar, Mohamed I; Yousief, Salah A; Kataia, Engy M; El-Wahab, Tarek M Abd

    2016-01-01

    In the present study, GTX and ProTaper as continuous rotating endodontic files were numerically compared with WaveOne reciprocating file using finite element analysis, aiming at having a low cost, accurate/trustworthy comparison as well as finding out the effect of instrument design and manufacturing material on its lifespan. Two 3D finite element models were especially prepared for this comparison. Commercial engineering CAD/CAM package was used to model full detailed flute geometries of the instruments. Multi-linear materials were defined in analysis by using real strain-stress data of NiTi and M-Wire. Non-linear static analysis was performed to simulate the instrument inside root canal at a 45° angle in the apical portion and subjected to 0.3 N.cm torsion. The three simulations in this study showed that M-Wire is slightly more resistant to failure than conventional NiTi. On the other hand, both materials are fairly similar in case of severe locking conditions. For the same instrument geometry, M-Wire instruments may have longer lifespan than the conventional NiTi ones. In case of severe locking conditions both materials will fail similarly. Larger cross sectional area (function of instrument taper) resisted better to failure than the smaller ones, while the cross sectional shape and its cutting angles could affect instrument cutting efficiency.

  7. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

    PubMed

    Gambarini, Gianluca; Grande, Nicola Maria; Plotino, Gianluca; Somma, Francesco; Garala, Manish; De Luca, Massimo; Testarelli, Luca

    2008-08-01

    The aim of the present study was to investigate whether cyclic fatigue resistance is increased for nickel-titanium instruments manufactured by using new processes. This was evaluated by comparing instruments produced by using the twisted method (TF; SybronEndo, Orange, CA) and those using the M-wire alloy (GTX; Dentsply Tulsa-Dental Specialties, Tulsa, OK) with instruments produced by a traditional NiTi grinding process (K3, SybronEndo). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (p < 0.05) in the mean number of cycles to failure when compared with size 06-25 K3 files. Size 06-20 K3 instruments showed no significant increase (p > 0.05) in the mean number of cycles to failure when compared with size 06-20 GT series X instruments. The new manufacturing process produced nickel-titanium rotary files (TF) significantly more resistant to fatigue than instruments produced with the traditional NiTi grinding process. Instruments produced with M-wire (GTX) were not found to be more resistant to fatigue than instruments produced with the traditional NiTi grinding process.

  8. Microbiological assessment of root canals following use of rotary and manual instruments in primary molars.

    PubMed

    Subramaniam, Priya; Tabrez, T A; Babu, K L Girish

    2013-01-01

    To assess the microflora of root canals in primary molars following use of rotary NiTi files and conventional hand NiTi and stainless steel files. This randomized clinical trial consisted of a total of 60 first and second primary molars requiring root canal treatment, who were selected from children aged 5-9 years. Based on type of root canal instrumentation, the teeth were randomly assigned to three groups of twenty teeth each; Group A: Rotary NiTi files, Group B: Hand NiTi files and Group C: Hand stainless steel files. Following administration of local anesthesia, isolation with rubber dam was carried out. For the purpose of instrumentation and sampling, the palatal canal of maxillary molars and the distal canal of mandibular molars were selected. Prior to sampling, the orifices of other canals in these teeth were sealed, so as to prevent any contamination. Instrumentation was carried out in each group using respective instruments along with intermittent saline irrigation. Root canal samples were obtained both before and after instrumentation, using sterile absorbent paper points and transferred to a sterile vial with transport fluid. Serial dilutions were prepared and cultured on suitable agar media. Both aerobic and anaerobic microbial counts were made. Data obtained was subjected to statistical analysis using Wilcoxon signed rank test and one-way Analysis of variance. In all three groups, there was a significant reduction in both aerobic and anaerobic mean microbial count following root canal instrumentation. (p < 0.001). Rotary NiTi files were as efficient as conventional hand instruments in significantly reducing the root canal microflora.

  9. A review of instrumentation kinematics of engine-driven nickel-titanium instruments.

    PubMed

    Çapar, I D; Arslan, H

    2016-02-01

    Over the years, NiTi alloys have become indispensable materials in endodontic treatment. With technological advancements in metallurgy, manufacturers have attempted to produce instruments with enhanced features. In parallel with these developments, endodontic motors have undergone improvements in terms of torque control and kinematics that are adjustable in different directions. This review presents an overview of the advancements in instrumentation kinematics and the effect of instrumentation kinematics on root canal shaping procedures and instrument performance. The literature search for this narrative review was conducted in Google Scholar, Scopus, PubMed and Web of Science using the keywords 'kinematics and endodontics' and 'reciprocation and endodontics'. In addition, historical literature was searched using the keyword 'nickel-titanium and endodontics'. Overall, 143 articles were included up to 2015. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  10. Root canal centering ability of rotary cutting nickel titanium instruments: A meta-analysis

    PubMed Central

    Gundappa, Mohan; Bansal, Rashmi; Khoriya, Sarvesh; Mohan, Ranjana

    2014-01-01

    Aim: To systematically review articles on canal centering ability of endodontic rotary cutting Nickel-Titanium (Ni-Ti) instruments and subject results to meta-analysis. Materials and Methods: A comprehensive search was initiated on canal centering ability of different rotary cutting Ni-Ti files such as Protaper, Hero Shaper, K3, Mtwo, Race, Wave One by selecting articles published in peer reviewed journals during 1991-2013 using “Pub Med” database. Inclusion and exclusion criteria were established. A data was created by tabulating: Author name, publication year, sample size, number of experimental groups, methods to evaluate canal centering ability, instrument cross section, taper, tip design, rake angle, mean and standard deviation. The data generated was subjected to meta-analysis. Results: Maximum studies were found to be conducted on mesiobuccal canal of mandibular 1st molar with curvature ranging from 15-60°. The difference in canal centering ability of different rotary cutting Ni-Ti instruments was not statistically significant. Conclusion: All endodontic rotary cutting Ni-Ti instruments are capable of producing centered preparations. Protaper depicted the best centering ability. Computed tomography is an effective method of evaluating canal centering ability. PMID:25506134

  11. Effect of environment on low-cycle fatigue of a nickel-titanium instrument.

    PubMed

    Cheung, Gary S P; Shen, Ya; Darvell, Brian W

    2007-12-01

    This study examined the low-cycle fatigue (LCF) behavior of a nickel-titanium (NiTi) engine-file under various environmental conditions. One brand of NiTi instrument was subjected to rotational-bending fatigue in air, deionized water, sodium hypochlorite, or silicone oil. The curvature of each instrument, diameter of the fracture cross-section, and the number of rotations to failure were determined. The strain-life relationship in the LCF region was examined by using one-way analysis of variance, and the number of crack origins with chi2, for differences between groups. The results showed a linear relationship, on logarithmic scales, between the LCF life and the surface strain amplitude; regression line slopes were significantly different between noncorrosive (air, silicone oil) and corrosive (water, hypochlorite) environments (P < .05), as well as number of crack origins (P < .05). Hypochlorite was more detrimental to fatigue life than water. In conclusion, environmental conditions significantly affect the LCF behavior of NiTi rotary instruments. Fatigue testing of NiTi engine-files should be in a service-like environment.

  12. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.

    PubMed

    Guelzow, A; Stamm, O; Martus, P; Kielbassa, A M

    2005-10-01

    To compare ex vivo various parameters of root canal preparation using a manual technique and six different rotary nickel-titanium (Ni-Ti) instruments (FlexMaster, System GT, HERO 642, K3, ProTaper, and RaCe). A total of 147 extracted mandibular molars were divided into seven groups (n = 21) with equal mean mesio-buccal root canal curvatures (up to 70 degrees), and embedded in a muffle system. All root canals were prepared to size 30 using a crown-down preparation technique for the rotary nickel-titanium instruments and a standardized preparation (using reamers and Hedströem files) for the manual technique. Length modifications and straightening were determined by standardized radiography and a computer-aided difference measurement for every instrument system. Post-operative cross-sections were evaluated by light-microscopic investigation and photographic documentation. Procedural errors, working time and time for instrumentation were recorded. The data were analysed statistically using the Kruskal-Wallis test and the Mann-Whitney U-test. No significant differences were detected between the rotary Ni-Ti instruments for alteration of working length. All Ni-Ti systems maintained the original curvature well, with minor mean degrees of straightening ranging from 0.45 degrees (System GT) to 1.17 degrees (ProTaper). ProTaper had the lowest numbers of irregular post-operative root canal diameters; the results were comparable between the other systems. Instrument fractures occurred with ProTaper in three root canals, whilst preparation with System GT, HERO 642, K3 and the manual technique resulted in one fracture each. Ni-Ti instruments prepared canals more rapidly than the manual technique. The shortest time for instrumentation was achieved with System GT (11.7 s). Under the conditions of this ex vivo study all Ni-Ti systems maintained the canal curvature, were associated with few instrument fractures and were more rapid than a standardized manual technique. Pro

  13. Fatigue and nanomechanical properties of K3XF nickel-titanium instruments.

    PubMed

    Shen, Y; Zhou, H; Campbell, L; Wang, Z; Wang, R; Du, T; Haapasalo, M

    2014-12-01

    To examine the fatigue behaviour of heat-treated NiTi instruments when immersed in aqueous media and to determine the effect of cyclic fatigue on the hardness and elastic modulus of NiTi instruments using a nanoindentation technique. K3XF and K3 NiTi instruments, both in sizes 25, 0.04 taper and 40, 0.04 taper, were subjected to rotational bending at a curvature of 42° either in air or under deionized water, and the number of revolutions to fracture (Nf ) was recorded. The fracture surface of all fragments was examined with a scanning electron microscope. The hardness and elastic modulus of the fracture surface of instruments sized 25, 0.04 taper were then measured using a nanoindentation test. The K3XF instruments had a fatigue resistance superior to K3 instruments under dry and aqueous environments (P < 0.05). The fatigue life of K3 instruments was similar under both conditions, whereas the Nf of K3XF was greater under water than in air, especially at the size 40, 0.04 taper (P < 0.05). The values for the fraction of the area occupied by the dimple region were significantly smaller in K3XF instruments than in K3 instruments, especially under water (P < 0.05). There was no difference in hardness on K3XF instruments between new files and instruments subjected to the fatigue process. The hardness of instruments subjected to the fatigue process was significantly lower in K3XF than in K3 instruments (P < 0.05). The fatigue life of K3XF instruments under water is longer than it is for K3XF instruments in air. There was no work-hardening effect on K3XF instruments subjected to the fatigue process. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. In search of colonial El Niño events and a brief history of meteorology in Ecuador

    NASA Astrophysics Data System (ADS)

    Terneus, A.; Gioda, A.

    2006-02-01

    This study shows a brief overview of the development of meteorology in Ecuador from historical documentation of climatic events in the Colonial era through to modern data collection. In the colonial era (16th century-1824), historical documents of rogation ceremonies and municipal proceedings, from the Quito area, provide a rich source of climate information, including El Niño events. Our preliminary findings show that very few of the historically documented catastrophes and other marked environmental events in Quito match known El Niño episodes. Independently, the first meteorological data was collected in Ecuador (beginning with La Condamine in 1738), followed by the earliest attempts to build a national meteorological network in the 1860's, linked closely to President Gabriel García Moreno and the Jesuits. The 1925 El Niño phenomenon was the first important meteorological episode recorded with scientific instrumentation in Ecuador, with newspapers providing complementary archives about the extreme impact of this event.

  15. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation - An In vitro Study.

    PubMed

    Devale, Madhuri R; Mahesh, M C; Bhandary, Shreetha

    2017-01-01

    Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than

  16. 76 FR 34208 - NIST Designation of Cannon Instrument Company as the Responsible Organization for U.S. National...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-13

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology NIST Designation of Cannon..., Commerce. ACTION: Notice. SUMMARY: The National Institute of Standards and Technology (NIST), as the... relevant to that particular measurand. This notice announces that NIST has designated the Cannon Instrument...

  17. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation – An In vitro Study

    PubMed Central

    Mahesh, MC; Bhandary, Shreetha

    2017-01-01

    Introduction Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. Aim This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. Materials and Methods In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Results Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files

  18. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    ERIC Educational Resources Information Center

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  19. Ex vivo study on root canal instrumentation of two rotary nickel-titanium systems in comparison to stainless steel hand instruments.

    PubMed

    Vaudt, J; Bitter, K; Neumann, K; Kielbassa, A M

    2009-01-01

    To investigate instrumentation time, working safety and the shaping ability of two rotary nickel-titanium (NiTi) systems (Alpha System and ProTaper Universal) in comparison to stainless steel hand instruments. A total of 45 mesial root canals of extracted human mandibular molars were selected. On the basis of the degree of curvature the matched teeth were allocated randomly into three groups of 15 teeth each. In group 1 root canals were prepared to size 30 using a standardized manual preparation technique; in group 2 and 3 rotary NiTi instruments were used following the manufacturers' instructions. Instrumentation time and procedural errors were recorded. With the aid of pre- and postoperative radiographs, apical straightening of the canal curvature was determined. Photographs of the coronal, middle and apical cross-sections of the pre- and postoperative canals were taken, and superimposed using a standard software. Based on these composite images the portion of uninstrumented canal walls was evaluated. Active instrumentation time of the Alpha System was significantly reduced compared with ProTaper Universal and hand instrumentation (P < 0.05; anova). No instrument fractures occurred in any of the groups. The Alpha System revealed significantly less apical straightening compared with the other instruments (P < 0.05; Mann-Whitney U test). In the apical cross-sections Alpha System resulted in significantly less uninstrumented canal walls compared with stainless steel files (P < 0.05; chi-squared test). Despite the demonstrated differences between the systems, an apical straightening effect could not be prevented; areas of uninstrumented root canal wall were left in all regions using the various systems.

  20. The contextual effects of social capital on health: a cross-national instrumental variable analysis.

    PubMed

    Kim, Daniel; Baum, Christopher F; Ganz, Michael L; Subramanian, S V; Kawachi, Ichiro

    2011-12-01

    Past research on the associations between area-level/contextual social capital and health has produced conflicting evidence. However, interpreting this rapidly growing literature is difficult because estimates using conventional regression are prone to major sources of bias including residual confounding and reverse causation. Instrumental variable (IV) analysis can reduce such bias. Using data on up to 167,344 adults in 64 nations in the European and World Values Surveys and applying IV and ordinary least squares (OLS) regression, we estimated the contextual effects of country-level social trust on individual self-rated health. We further explored whether these associations varied by gender and individual levels of trust. Using OLS regression, we found higher average country-level trust to be associated with better self-rated health in both women and men. Instrumental variable analysis yielded qualitatively similar results, although the estimates were more than double in size in both sexes when country population density and corruption were used as instruments. The estimated health effects of raising the percentage of a country's population that trusts others by 10 percentage points were at least as large as the estimated health effects of an individual developing trust in others. These findings were robust to alternative model specifications and instruments. Conventional regression and to a lesser extent IV analysis suggested that these associations are more salient in women and in women reporting social trust. In a large cross-national study, our findings, including those using instrumental variables, support the presence of beneficial effects of higher country-level trust on self-rated health. Previous findings for contextual social capital using traditional regression may have underestimated the true associations. Given the close linkages between self-rated health and all-cause mortality, the public health gains from raising social capital within and across

  1. The contextual effects of social capital on health: a cross-national instrumental variable analysis

    PubMed Central

    Kim, Daniel; Baum, Christopher F; Ganz, Michael; Subramanian, S V; Kawachi, Ichiro

    2011-01-01

    Past observational studies of the associations of area-level/contextual social capital with health have revealed conflicting findings. However, interpreting this rapidly growing literature is difficult because estimates using conventional regression are prone to major sources of bias including residual confounding and reverse causation. Instrumental variable (IV) analysis can reduce such bias. Using data on up to 167 344 adults in 64 nations in the European and World Values Surveys and applying IV and ordinary least squares (OLS) regression, we estimated the contextual effects of country-level social trust on individual self-rated health. We further explored whether these associations varied by gender and individual levels of trust. Using OLS regression, we found higher average country-level trust to be associated with better self-rated health in both women and men. Instrumental variable analysis yielded qualitatively similar results, although the estimates were more than double in size in women and men using country population density and corruption as instruments. The estimated health effects of raising the percentage of a country's population that trusts others by 10 percentage points were at least as large as the estimated health effects of an individual developing trust in others. These findings were robust to alternative model specifications and instruments. Conventional regression and to a lesser extent IV analysis suggested that these associations are more salient in women and in women reporting social trust. In a large cross-national study, our findings, including those using instrumental variables, support the presence of beneficial effects of higher country-level trust on self-rated health. Past findings for contextual social capital using traditional regression may have underestimated the true associations. Given the close linkages between self-rated health and all-cause mortality, the public health gains from raising social capital within countries may

  2. Super instrumental El Niño events recorded by a Porites coral from the South China Sea

    NASA Astrophysics Data System (ADS)

    Wang, Xijie; Deng, Wenfeng; Liu, Xi; Wei, Gangjian; Chen, Xuefei; Zhao, Jian-xin; Cai, Guanqiang; Zeng, Ti

    2018-03-01

    The 2-7-year periodicities recorded in fossil coral records have been widely used to identify paleo-El Niño events. However, the reliability of this approach in the South China Sea (SCS) has not been assessed in detail. Therefore, this paper presents monthly resolution geochemical records covering the period 1978-2015 obtained from a Porites coral recovered from the SCS to test the reliability of this method. The results suggest that the SCS coral reliably recorded local seawater conditions and the super El Niño events that occurred over the past 3 decades, but does not appear to have been sensitive enough to record all the other El Niños. In detail, the Sr/Ca series distinctly documents only the two super El Niños of 1997-1998 and 2014-2016 as obvious low values, but does not match the Oceanic Niño Index well. The super El Niño of 1982-1983 was identified by the growth hiatus caused by the coral bleaching and subsequent death of the coral. Three distinct stepwise variations occur in the δ13C series that are coincident with the three super El Niños, which may be related to a substantial decline in endosymbiotic zooxanthellae density caused by the increase in temperature during an El Niño or the selective utilization of different zooxanthellaes that was required to survive in the extreme environment. The increase in rainfall and temperatures over the SCS during El Niños counteracts the effects on seawater δ18O (δ18Osw) and salinity; consequently, coral Δδ18O series can be used as a proxy for δ18Osw and salinity, but are not appropriate for identifying El Niño activity. The findings presented here suggest that the method to identify paleo-El Niño activity based on the 2-7-year periodicities preserved in the SCS coral records might not be reliable, because the SCS is on the edge of El Niño anomalies due to its great distance from the central equatorial Pacific and the imprints of weak and medium strength El Niño events may not be recorded by the

  3. A comparative evaluation of cleaning efficacy (debris and smear layer removal) of hand and two NiTi rotary instrumentation systems (K3 and ProTaper): a SEM study.

    PubMed

    Reddy, K Balakoti; Dash, Shreemoy; Kallepalli, Sowmya; Vallikanthan, Sangeetha; Chakrapani, N; Kalepu, Vamsi

    2013-11-01

    The present study was conducted to compare the cleaning efficacy (debris and smear layer removal) of hand and two NiTi rotary instrumentation systems (K3 and ProTaper). Sixty single rooted human maxillary anterior teeth decoronated at the cementoenamel junction were used. All the specimens were divided into four groups of 15 teeth each, group I--ProTaper rotary instrumentation done, group II--K3 rotary instrumentation done, group III--Stainless steel K-file instrumentation done, group IV--root canal irrigation without instrumentation. Root canal preparation was done in a crown down manner and 3% sodium hypochlorite was used as irrigant after each file followed by final rinse with 5 ml of 17% EDTA solution, then specimens were scanning electron microscopic (SEM) examination. Statistical analysis was done using one-way ANOVA followed by post hoc Tukey's HSD test. Group I showed highly statistical significant difference compared to other groups. There was no statistically significant difference considering smear layer at any levels among the groups with no smear layer formation in group IV. ProTaper rotary instrumentation showed the maximum cleaning efficacy followed by K3 rotary instrumentation in the coronal, middle and apical thirds of the root canal. ProTaper rotary instruments are more efficient than hand and K3 rotary instruments during root canal treatment.

  4. Pitting corrosion resistance of nickel-titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic Acid and sodium chloride solutions.

    PubMed

    Bonaccorso, Antonio; Tripi, Teresa Roberta; Rondelli, Gianni; Condorelli, Guglielmo Guido; Cantatore, Giuseppe; Schäfer, Edgar

    2008-02-01

    This study evaluated the pitting corrosion resistance of nickel-titanium (NiTi) rotary instruments with different surface treatments in 17% ethylenediaminetetraacetic acid (EDTA) and NaCl solutions. Electropolished RaCe instruments were allocated to group A, non-electropolished RaCe instruments to group B, and physical vapor deposition (PVD)-coated Alpha files to group C (10 instruments per group). Electrochemical measurements were carried out by using a potentiostat for galvanic current measurements. On the basis of electrochemical tests, no localized corrosion problems are to be expected in EDTA. In NaCl, pitting potential occurred at higher values for the electropolished and PVD instruments, indicating an increased corrosion resistance. There appears to be a risk of corrosion for NiTi instruments without surface treatments in contact with NaCl. NiTi files with PVD and electropolishing surface treatments showed an increase corrosion resistance.

  5. Assessment Instruments Used in the Education and Treatment of Persons with Autism: Brief Report of a Survey of National Service Centers.

    ERIC Educational Resources Information Center

    Luiselli, James K.; Campbell, Susan; Cannon, Barbara; DiPietro, Ellette; Ellis, James T.; Taras, Marie; Lifter, Karin

    2001-01-01

    Data from 30 national service centers found the number of assessment instruments endorsed increased as centers adopted a multidisciplinary approach to education and treatment, the largest proportion of instruments fell within intellectual, motor, and language/communication domains, and instruments were used most frequently for diagnostic and…

  6. Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial.

    PubMed

    Kashefinejad, Mohamad; Harandi, Azade; Eram, Saeed; Bijani, Ali

    2016-01-01

    Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student's t-test (P<0.05). Patients treated with rotary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (P<0.001). The use of Mtwo (NiTi) rotary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files.

  7. Biocompatilibity-related surface characteristics of oxidized NiTi.

    PubMed

    Danilov, Anatoli; Tuukkanen, Tuomas; Tuukkanen, Juha; Jämsä, Timo

    2007-09-15

    In the present study, we examined the effect of NiTi oxidation on material surface characteristics related to biocompatibility. Correspondence between electron work function (EWF) and adhesive force predicted by electron theory of adsorption as well as the effect of surface mechanical stress on the adhesive force were studied on the nonoxidized and oxidized at 350, 450, and 600 degrees C NiTi alloy for medical application. The adhesive force generated by the material surface towards the drops of alpha-minimal essential medium (alpha-MEM) was used as a characteristic of NiTi adsorption properties. The study showed that variations in EWF and mechanical stress caused by surface treatment were accompanied by variations in adhesive force. NiTi oxidation at all temperatures used gave rise to decrease in adhesive force and surface stress values in comparison to the nonoxidized state. In contrary, the EWF value revealed increase under the same condition. Variations in surface oxide layer thickness and its phase composition were also followed. The important role of oxide crystallite size in EWF values within the range of crystallite dimensions typical for NiTi surface oxide as an instrument for the fine regulation of NiTi adsorption properties was demonstrated. The comparative oxidation of pure titanium and NiTi showed that the effect of Ni on the EWF value of NiTi surface oxide is negligible. Copyright 2007 Wiley Periodicals, Inc.

  8. Root dentine and endodontic instrumentation: cutting edge microscopic imaging

    PubMed Central

    2016-01-01

    Cutting of the dental hard tissues is an integral part of restorative dentistry. Cutting of the root dentine is also needed in preparation prior to endodontic treatment, with significant commercial investment for the development of flexible cutting instruments based around nickel titanium (NiTi) alloys. This paper describes the evolution of endodontic cutting instruments, both in materials used, e.g. the transition from stainless steel to NiTi, and the design of the actual instruments themselves and their method of activation—by hand or motor driven. We have been examining tooth-cutting interactions microscopically for over 25 years using a variety of microscopic techniques; in particular, video-rate confocal microscopy. This has given a unique insight into how many of the procedures that we take for granted are achieved in clinical practice, by showing microscopic video images of the cutting as it occurs within the tooth. This technology has now been extended to allow imaging of the endodontic instrument and the root canal wall for the first time. We are able to image dentine distortion and crack propagation during endodontic filing of the root canal space. We are also able to visualize the often claimed, but seldom seen action of contemporary endodontic instruments. PMID:27274802

  9. Root dentine and endodontic instrumentation: cutting edge microscopic imaging.

    PubMed

    Atmeh, Amre R; Watson, Timothy F

    2016-06-06

    Cutting of the dental hard tissues is an integral part of restorative dentistry. Cutting of the root dentine is also needed in preparation prior to endodontic treatment, with significant commercial investment for the development of flexible cutting instruments based around nickel titanium (NiTi) alloys. This paper describes the evolution of endodontic cutting instruments, both in materials used, e.g. the transition from stainless steel to NiTi, and the design of the actual instruments themselves and their method of activation-by hand or motor driven. We have been examining tooth-cutting interactions microscopically for over 25 years using a variety of microscopic techniques; in particular, video-rate confocal microscopy. This has given a unique insight into how many of the procedures that we take for granted are achieved in clinical practice, by showing microscopic video images of the cutting as it occurs within the tooth. This technology has now been extended to allow imaging of the endodontic instrument and the root canal wall for the first time. We are able to image dentine distortion and crack propagation during endodontic filing of the root canal space. We are also able to visualize the often claimed, but seldom seen action of contemporary endodontic instruments.

  10. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth

    PubMed Central

    Govindaraju, Lavanya; Subramanian, EMG

    2017-01-01

    Introduction Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. Aim To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Materials and Methods Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. Results No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. Conclusion The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual

  11. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    PubMed

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in

  12. Implementing Audio Digital Feedback Loop Using the National Instruments RIO System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, G.; Byrd, J. M.

    2006-11-20

    Development of system for high precision RF distribution and laser synchronization at Berkeley Lab has been ongoing for several years. Successful operation of these systems requires multiple audio bandwidth feedback loops running at relatively high gains. Stable operation of the feedback loops requires careful design of the feedback transfer function. To allow for flexible and compact implementation, we have developed digital feedback loops on the National Instruments Reconfigurable Input/Output (RIO) platform. This platform uses an FPGA and multiple I/Os that can provide eight parallel channels running different filters. We present the design and preliminary experimental results of this system.

  13. Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial

    PubMed Central

    Kashefinejad, Mohamad; Harandi, Azade; Bijani, Ali

    2016-01-01

    Objectives: Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. Materials and Methods: In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student’s t-test (P<0.05). Results: Patients treated with rotary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (P<0.001). Conclusions: The use of Mtwo (NiTi) rotary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files. PMID:27536323

  14. A comparison of nickel-titanium rotary instruments manufactured using different methods and cross-sectional areas: ability to resist cyclic fatigue.

    PubMed

    Oh, So-Ram; Chang, Seok-Woo; Lee, Yoon; Gu, Yu; Son, Won-Jun; Lee, Woocheol; Baek, Seung-Ho; Bae, Kwang-Shik; Choi, Gi-Woon; Lim, Sang-Min; Kum, Kee-Yeon

    2010-04-01

    This study examined the effect of the manufacturing methods (ground, electropolished, and twisted) and the cross-sectional area (CSA) of nickel-titanium (NiTi) rotary instruments on their cyclic fatigue resistance. A total of 80 NiTi rotary instruments (ISO 25/.06 taper) from 4 brands (K3, ProFile, RaCe, and TF) were rotated in a simulated root canal with pecking motion until fracture. The number of cycles to failure (NCF) was calculated. The CSA at 3 mm from the tip of new instruments of each brand was calculated. The correlation between the CSA and NCF was evaluated. All fractured surfaces were analyzed using a scanning electron microscope to determine the fracture mode. The TF instruments were the most resistant to fatigue failure. The resistance to cyclic failure increased with decreasing CSA. All fractured surfaces showed the coexistence of ductile and brittle properties. The CSA had a significant effect on the fatigue resistance of NiTi rotary instruments. Copyright 2010 Mosby, Inc. All rights reserved.

  15. A metric for quantifying El Niño pattern diversity with implications for ENSO-mean state interaction

    NASA Astrophysics Data System (ADS)

    Lemmon, Danielle E.; Karnauskas, Kristopher B.

    2018-04-01

    Recent research on the El Niño-Southern Oscillation (ENSO) phenomenon increasingly reveals the highly complex and diverse nature of ENSO variability. A method of quantifying ENSO spatial pattern uniqueness and diversity is presented, which enables (1) formally distinguishing between unique and "canonical" El Niño events, (2) testing whether historical model simulations aptly capture ENSO diversity by comparing with instrumental observations, (3) projecting future ENSO diversity using future model simulations, (4) understanding the dynamics that give rise to ENSO diversity, and (5) analyzing the associated diversity of ENSO-related atmospheric teleconnection patterns. Here we develop a framework for measuring El Niño spatial SST pattern uniqueness and diversity for a given set of El Niño events using two indices, the El Niño Pattern Uniqueness (EPU) index and El Niño Pattern Diversity (EPD) index, respectively. By applying this framework to instrumental records, we independently confirm a recent regime shift in El Niño pattern diversity with an increase in unique El Niño event sea surface temperature patterns. However, the same regime shift is not observed in historical CMIP5 model simulations; moreover, a comparison between historical and future CMIP5 model scenarios shows no robust change in future ENSO diversity. Finally, we support recent work that asserts a link between the background cooling of the eastern tropical Pacific and changes in ENSO diversity. This robust link between an eastern Pacific cooling mode and ENSO diversity is observed not only in instrumental reconstructions and reanalysis, but also in historical and future CMIP5 model simulations.

  16. Effectiveness of Rotary Endodontic Instruments on Smear Layer Removal in Root Canals of Primary Teeth: A Scanning Electron Microscopy Study.

    PubMed

    Subramaniam, Priya; Girish Babu, K L; Tabrez, T A

    2016-01-01

    The present SEM study was undertaken to evaluate the effect of root canal instrumentation using both manual and rotary files in the root canals of primary anterior teeth. Thirty freshly extracted primary maxillary incisors were divided into 3 groups of 10 teeth each. In Group I, root canals were instrumented with rotary NiTi files; in Group II, the root canals were instrumented using manual NiTi K files and; in Group III, manual instrumentation was done with stainless steel K files. Longitudinal sections were prepared and processed for observation under SEM at the coronal, middle and apical thirds. Scoring of smear layer was done according to Hulsmann and the data obtained was subjected to statistical analysis. Rotary files cleaned the coronal and middle thirds of root canals more effectively. Statistically there was no significant difference between the groups. Lowest score of 2.6 in the apical third of root canals was seen with hand NiTi files. Rotary instrumentation was as effective as manual instrumentation in removal of smear layer in the root canals of primary anterior teeth.

  17. Determining cutting efficiency of nickel-titanium coronal flaring instruments used in lateral action.

    PubMed

    Peters, O A; Morgental, R D; Schulze, K A; Paqué, F; Kopper, P M P; Vier-Pelisser, F V

    2014-06-01

    To develop a method to evaluate the cutting behaviour of nickel-titanium (NiTi) coronal flaring instruments. BioRaCe BR0 (BR), HyFlex CM 1 (HY), ProFile OS No. 2 (PF) and ProTaper Sx (PT) instruments were used in simulated coronal flaring using a lateral action against bovine dentine blocks, at 250 and 500 rpm. Cutting efficiency was assessed by three methods: first, areas of notches produced by instruments were directly measured under a stereomicroscope. Second, dentine specimens were then analysed by surface profilometry to determine the maximum cutting depth and finally by microcomputed tomography to assess the volume of removed dentine. Data were compared using parametric tests with the significance level set at 0.05. For all three methods, HY and PF were the most and the least cutting-efficient instruments, respectively (P < 0.05). Significant differences were detected between 250 and 500 rpm for HY and PT (area); for BR, HY and PT (depth); and for BR and HY (volume). There were strong positive correlations between the results obtained with those three different methods with r-values ranging from 0.81 to 0.92. Measuring the amount of material removed in a specific time under stereomicroscopy is a simple and rational way to assess the cutting behaviour of NiTi rotary instruments in lateral action. HyFlex, manufactured with thermomechanically treated NiTi wire, was the most efficient instrument, and increased rotational speed was associated with increased cutting efficiency. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  18. Screw-in forces during instrumentation by various file systems.

    PubMed

    Ha, Jung-Hong; Kwak, Sang Won; Kim, Sung-Kyo; Kim, Hyeon-Cheol

    2016-11-01

    The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS- k , DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest ( p < 0.05). Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.

  19. [µCT analysis of mandibular molars before and after instrumentation by Reciproc files].

    PubMed

    Ametrano, Gianluca; Riccitiello, Francesco; Amato, Massimo; Formisano, Anna; Muto, Massimo; Grassi, Roberta; Valletta, Alessandra; Simeone, Michele

    2013-01-01

    Cleaning and shaping are important section for the root canal treatment. A number of different methodologies have been developed to overcome these problems, including the introduction of rotary instruments nickel-titanium (NiTi). In endodontics NiTi have been shown to significantly reduce procedural errors compared to manual techniques of instrumentation. The efficiency of files is related to many factor. Although previous investigations that have used µCT analysis were hampered by insufficient resolution or projection incorrect. The new generation of μCT performance best offer, as micron resolution and accurate measurement software for evaluating the accurate anatomy of the root canal. The aim the paper was to evaluate the efficiency of Reciproc files in root canal treatment, evaluated before and after instrumentation by using μ-CT analysis.

  20. Focal plane mechanical design of the NISP/Euclid instrument

    NASA Astrophysics Data System (ADS)

    Bonnefoi, Anne; Bon, William; Niclas, Mathieu; Solheim, Bjarte G. B.; Torvanger, Oyvind; Schistad, Robert; Foulon, Benjamin; Garcia, José; Vives, Sébastien

    2016-07-01

    Currently in phase C, the Euclid mission selected by ESA in the Cosmic Vision program is dedicated to understand dark energy and dark matter. NISP (standing for Near Infrared Spectro-Photometer) is one of the two instruments of the mission. NISP will combine a photometer and a spectrometer working in the near-IR (0.9-2 microns). Its detection subsystem (called NI-DS) is based on a mosaic of 16 IR detectors cooled down to 90K which are supported by a molybdenum plate. The front-end readout electronics (working at 130K) are supported by another structure in Aluminum. The NI-DS is mounted on the rest of the instrument thanks to a panel in Silicon Carbide (SiC). Finally an optical baffle in Titanium will prevent the rogue light to reach the detectors. On top of the complexity due to the wide range of temperatures and the various materials imposed at the interfaces; the NI-DS has also to incorporate an internal adjustment capability of the position of the focal plane in tip/tilt and focus. This article will present current status of the development of the detection system of NISP.

  1. Effect of alloy type on the life-time of torsion-preloaded nickel-titanium endodontic instruments.

    PubMed

    Ha, Jung-Hong; Kim, Sung Kyo; Cheung, Gary Shun-Pan; Jeong, Seong Hwa; Bae, Yong Chul; Kim, Hyeon-Cheol

    2015-01-01

    This study was aimed to evaluate the effect of torsional preloads on the cyclic fatigue life of nickel-titanium (NiTi) instruments with different history of heat treatments by manufacturers. WaveOne (Primary) made of M-wire, K3XF (#30/0.06) of R-phase, and ProTaper (F2) of conventional NiTi alloy was used. Each file was preloaded at four conditions (nil, 25, 50, and 75% of their mean ultimate torsional strength) before fatigue testing. The torsional preloads 10-, 30-, or 50-times were applied by securing 5 mm of the file tip, rotating it until the preset torque was attained before returning to the origin. Then, the number of cycles to failure (NCF) was evaluated by rotational bending in a simulated canal. Data were analyzed using multiple linear regression analysis and two-way ANOVA. Fractured instruments were examined under scanning electron microscope (SEM). SEM showed that most WaveOne after 75% preloading, regardless of repetitions, showed some longitudinal cracks parallel to the long axis of the file, which were rare for K3XF. Regression analysis revealed that the brand of instrument was the most critical factor. At up to 75% preloading, ProTaper and K3XF did not show any significant decline in NCF. For 30-repetition groups of WaveOne, the 50 and 25% torsion preloaded groups showed a significantly higher NCF than the 0 and 75% groups. Within the limitations of this study, the alloy type of NiTi instrument have a significant effect on the phenomenon that a certain amount of torsional preload may improve the cyclic fatigue resistance of NiTi rotary instruments. © Wiley Periodicals, Inc.

  2. Polishability of thin electrolytic and electroless NiP layers

    NASA Astrophysics Data System (ADS)

    Kinast, Jan; Beier, Matthias; Gebhardt, Andreas; Risse, Stefan; Tünnermann, Andreas

    2015-10-01

    Ultra-precise metal optics are key components of sophisticated scientific instrumentation in astronomy and space applications, covering a wide spectral range. Especially for applications in the visible or ultra-violet spectral ranges, a low roughness of the optics is required. Therefore, a polishable surface is necessary. State of the art is an amorphous nickel-phosphorus (NiP) layer, which enables several polishing techniques achieving a roughness of <1 nm RMS. Typically, these layers are approximately 30 μm to 60 μm thick. Deposited on Al6061, the bimetallic effect leads to a restricted operational temperature, caused by different coefficients of thermal expansion of Al6061 and NiP. Thinner NiP layers reduce the bimetallic effect. Hence, the possible operating temperature range. A deterministic shape correction via Magnetorheological Finishing of the substrate Al6061 leads to low shape deviations prior to the NiP deposition. This allows for depositing thin NiP-layers, which are polishable via a chemical mechanical polishing technique aiming at ultra-precise metal optics. The present article shows deposition processes and polishability of electroless and electrolytic NiP layers with thicknesses between 1 μm and 10 μm.

  3. Oxygen potentials in Ni + NiO and Ni + Cr2O3 + NiCr2O4 systems

    NASA Astrophysics Data System (ADS)

    Kale, G. M.; Fray, D. J.

    1994-06-01

    The chemical potential of O for the coexistence of Ni + NiO and Ni + Cr2O3 + NiCr2O4 equilibria has been measured employing solid-state galvanic cells, (+) Pt, Cu + Cu2O // (Y2O3)ZrO2 // Ni + NiO, Pt (-) and (+) Pt, Ni + NiO // (Y2O3)ZrO2 // Ni + Cr2O3 + NiCr2O4, Pt (-) in the temperature range of 800 to 1300 K and 1100 to 1460 K, respectively. The electromotive force (emf) of both the cells was reversible, reproducible on thermal cycling, and varied linearly with temperature. For the coexistence of the two-phase mixture of Ni + NiO, δΜO 2(Ni + NiO) = -470,768 + 171.77T (±20) J mol-1 (800 ≤ T ≤ 1300 K) and for the coexistence of Ni + Cr2O3 + NiCr2O4, δΜO 2(Ni + Cr2O3 + NiCr2O4) = -523,190 + 191.07T (±100) J mol-1 (1100≤ T≤ 1460 K) The “third-law” analysis of the present results for Ni + NiO gives the value of ‡H{298/o} = -239.8 (±0.05) kJ mol-1, which is independent of temperature, for the formation of one mole of NiO from its elements. This is in excellent agreement with the calorimetric enthalpy of formation of NiO reported in the literature.

  4. Characterization and electron-energy-loss spectroscopy on NiV and NiMo superlattices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahmood, S.H.

    1986-01-01

    NiV superlattices with periods (A) ranging from 15 to 80 A, and NiMo superlattices with from 14 to 110 A were studied using X-ray Diffraction (XRD), Electron Diffraction (ED), Energy-Dispersive X-Ray (EDX) microanalysis, and Electron Energy Loss Spectroscopy (EELS). Both of these systems have sharp superlattice-to-amorphous (S-A) transitions at about empty set = 17A. Superlattices with empty set around the S-A boundary were found to have large local variations in the in-plane grain sizes. Except for a few isolated regions, the chemical composition of the samples were found to be uniform. In samples prepared at Argonne National Laboratory (ANL), mostmore » places studied with EELS showed changes in the EELS spectrum with decreasing empty set. An observed growth in a plasmon peak at approx. 10ev in both NiV and NiMo as empty set decreased down to 19 A is attributed to excitation of interface plasmons. Consistent with this attribution, the peak height shrank in the amorphous samples. The width of this peak is consistent with the theory. The sift in this peak down to 9 ev with decreasing empty set in NiMo is not understood.« less

  5. Development and design of a late-model fitness test instrument based on LabView

    NASA Astrophysics Data System (ADS)

    Xie, Ying; Wu, Feiqing

    2010-12-01

    Undergraduates are pioneers of China's modernization program and undertake the historic mission of rejuvenating our nation in the 21st century, whose physical fitness is vital. A smart fitness test system can well help them understand their fitness and health conditions, thus they can choose more suitable approaches and make practical plans for exercising according to their own situation. following the future trends, a Late-model fitness test Instrument based on LabView has been designed to remedy defects of today's instruments. The system hardware consists of fives types of sensors with their peripheral circuits, an acquisition card of NI USB-6251 and a computer, while the system software, on the basis of LabView, includes modules of user register, data acquisition, data process and display, and data storage. The system, featured by modularization and an open structure, is able to be revised according to actual needs. Tests results have verified the system's stability and reliability.

  6. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments.

    PubMed

    Spagnuolo, G; Ametrano, G; D'Antò, V; Rengo, C; Simeone, M; Riccitiello, F; Amato, M

    2012-12-01

    To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments. © 2012 International Endodontic Journal.

  7. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement.

    PubMed

    De-Deus, G; Moreira, E J L; Lopes, H P; Elias, C N

    2010-12-01

    To evaluate the cyclic fatigue fracture resistance of engine-driven F2 ProTaper instruments under reciprocating movement. A sample of 30 NiTi ProTaper F2 instruments was used. An artificial canal was made from a stainless steel tube, allowing the instruments to rotate freely. During mechanical testing, different movement kinematics and speeds were used, which resulted in three experimental groups (n = 10). The instruments from the first group (G1) were rotated at a nominal speed of 250 rpm until fracture, whilst the instruments from the second group (G2) were rotated at 400 rpm. In the third instrument group (G3), the files were driven under reciprocating movement. The time of fracture for each instrument was measured, and statistical analysis was performed using parametric methods. Reciprocating movement resulted in a significantly longer cyclic fatigue life (P < 0.05). Moreover, operating rpm was a significant factor affecting cyclic fatigue life (P < 0.05); instruments used at a rotational speed of 400 rpm (approximately 95 s) failed more rapidly than those used at 250 rpm (approximately 25 s). Movement kinematics is amongst the factors determining the resistance of rotary NiTi instruments to cyclic fracture. Moreover, the reciprocating movement promoted an extended cyclic fatigue life of the F2 ProTaper instrument in comparison with conventional rotation.

  8. Evaluation of the psychometric properties of the Nighttime Symptoms of COPD Instrument.

    PubMed

    Mocarski, Michelle; Zaiser, Erica; Trundell, Dylan; Make, Barry J; Hareendran, Asha

    2015-01-01

    Nighttime symptoms can negatively impact the quality of life of patients with chronic obstructive pulmonary disease (COPD). The Nighttime Symptoms of COPD Instrument (NiSCI) was designed to measure the occurrence and severity of nighttime symptoms in patients with COPD, the impact of symptoms on nighttime awakenings, and rescue medication use. The objective of this study was to explore item reduction, inform scoring recommendations, and evaluate the psychometric properties of the NiSCI. COPD patients participating in a Phase III clinical trial completed the NiSCI daily. Item analyses were conducted using weekly mean and single day scores. Descriptive statistics (including percentage of respondents at floor/ceiling and inter-item correlations), factor analyses, and Rasch model analyses were conducted to examine item performance and scoring. Test-retest reliability was assessed for the final instrument using the intraclass correlation coefficient (ICC). Correlations with assessments conducted during study visits were used to evaluate convergent and known-groups validity. Data from 1,663 COPD patients aged 40-93 years were analyzed. Item analyses supported the generation of four scores. A one-factor structure was confirmed with factor analysis and Rasch analysis for the symptom severity score. Test-retest reliability was confirmed for the six-item symptom severity (ICC, 0.85), number of nighttime awakenings (ICC, 0.82), and rescue medication (ICC, 0.68) scores. Convergent validity was supported by significant correlations between the NiSCI, St George's Respiratory Questionnaire, and Exacerbations of Chronic Obstructive Pulmonary Disease Tool-Respiratory Symptoms scores. The results suggest that the NiSCI can be used to determine the severity of nighttime COPD symptoms, the number of nighttime awakenings due to COPD symptoms, and the nighttime use of rescue medication. The NiSCI is a reliable and valid instrument to evaluate these concepts in COPD patients in clinical

  9. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments.

    PubMed

    Haïkel, Y; Serfaty, R; Bateman, G; Senger, B; Allemann, C

    1999-06-01

    The absence of adequate testing standards for engine-driven nickel-titanium (NiTi) instruments necessitates further study of these instruments in all areas. This study examined three groups of engine-driven rotary NiTi endodontic instruments (Profile, Hero, and Quantec) and assessed the times for dynamic fracture in relation to the radius of curvature to which the instruments were subjected during preparation, with the instrument diameter determined by size and taper and the mode by which the fracture occurred. Ten instruments were randomly selected representing each size and taper for each group and for each radius of curvature: 600 in total. The instruments were rotated at 350 rpm and introduced into a tempered steel curve that simulated a canal. Two radii of curvature of canals were used: 5 and 10 mm. Time at fracture was noted for all files, and the fracture faces of each file were analyzed with scanning electron microscopy. Radius of curvature was found to be the most significant factor in determining the fatigue resistance of the files. As radius of curvature decreased, fracture time decreased. Taper of files was found to be significant in determining fracture time. As diameter increased, fracture time decreased. In all cases, fracture was found to be of a ductile nature, thus implicating cyclic fatigue as a major cause of failure and necessitating further analyses and setting of standards in this area.

  10. Measurements of 59Ni in meteorites by accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Paul, M.; Fifield, L. K.; Fink, D.; Albrecht, A.; Allan, G. L.; Herzog, G.; Tuniz, C.

    1993-10-01

    Isotopic abundances of the radionuclide 59Ni (T1/2 = 76000 yr) were measured by accelerator mass spectrometry with the 14UD Pelletron tandem accelerator at the Australian National University and a detection system solely based on a multianode ionization chamber. The sensitivity limit in the measurement of 59Ni isotopic abundances is 5 × 10-13, as determined by residual interferences from isobaric 59Co and isotopic 58Ni ions. Cosmogenic 59Ni abundances 59Ni/Ni = (8-20) × 10-12 were measured in four samples prepared from the metal phase of two meteorites (mesosiderites). The ratio of the 59Ni abundances to those measured for 41Ca in the silicate phase of the same samples, is in fair agreement with the ratio of the production rates via thermal-neutron capture on 58Ni and 40Ca.

  11. Instrumentation for Infrared Astronomy in the Collections of the National Air and Space Museum, Smithsonian Institution

    NASA Astrophysics Data System (ADS)

    DeVorkin, David H.

    2017-01-01

    The National Air and Space Museum of the Smithsonian Institution is responsible for preserving the material heritage of modern astronomical history. We place emphasis on American accomplishments, on both airborne and spaceborne instrumentation, and on ground based instrumentation that stimulated and supported spaceborne efforts. At present the astronomical collection includes over 600 objects, of which approximately 40 relate to the history of infrared astronomy. This poster will provide a simple listing of our holdings in infrared and far-infrared astronomy, and will highlight particularly significant early objects, like Cashman and Ektron cells, Leighton and Neugebauer's Caltech 2.2 micron survey telescope, Low's Lear Jet Bolometer, Harwit's first Aerobee IR payload and Fazio's balloon-borne observatory. Elements from more recent missions will also be included, such as instruments from KAO, an IRAS focal plane instrument, FIRAS from COBE, the payload from Boomerang and Woody and Richards' balloonsonde payload. The poster author will invite AAS members to comment on these holdings, provide short stories of their experiences building and using them, and suggest candidates for possible collection.

  12. Sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium instruments.

    PubMed

    Koçak, Mustafa M; Darendeliler-Yaman, Sis

    2012-07-01

    The aim of this study was to evaluate the sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium root canal instruments by fluid filtration method. The root canals were prepared with stainless steel (SS) and nickel titanium (NiTi) instruments. The canals prepared with SS were obturated with lateral compaction technique using .02 tapered cones and the canals prepared with NiTi instruments were obturated with lateral compaction technique using .02 tapered cones or 06 tapered single cones. The amount of leakage was evaluated by fluid filtration model. The results were statistically analyzed with one-way ANOVA. The group prepared with NiTi instruments and filled with lateral compaction technique showed significantly less coronal leakage than the group prepared with SS instruments and filled with lateral compaction technique (p<0.05). There was no statistically difference between apical leakages of groups (p>0.05). Obturation with lateral compaction of gutta-percha provides a superior coronal seal whilst canal instrumentation with engine-driven NiTi files reduces the extent of microleakage in root canals when compared with stainless steel hand instruments. Tapered single cone technique was comparable with lateral compaction technique because of easier application. Key words:Apical leakage, coronal leakage, lateral compaction technique, single cone technique.

  13. Comparison between rotary and manual instrumentation in primary teeth.

    PubMed

    Crespo, S; Cortes, O; Garcia, C; Perez, L

    2008-01-01

    The aim of this study was to compare the efficiency in both, preparation time and root canal shape, when using the Nickel Titanium (Ni-Ti) rotary and K-Files hand instrumentation on root canal preparation of single rooted primary teeth. Sixty single rooted primary teeth were selected and divided into two equal groups: Group (I) 30 teeth instrumented with manual K-files and group (II) 30 teeth instrumented with Ni-Ti rotary files (ProFile 0.04). Instrumentation times were calculated and root canal impressions were taken with light bodied silicone in order to evaluate the shape. The data was analyzed with SPSS program using the t-test and the Chi-square test to compare their means. The preparation time with group (I) K-files was significantly higher than in group (II) rotary files (ProFile 0.04), with a p= .005. The ProFile system showed a significantly more favorable canal taper when compared to the K-files system (P= .002). The use of rotary files in primary teeth has several advantages when compared with manual K files: the efficiency in both, preparation time and root canal shape. 1. A decreased working time, that helps maintain patient cooperation by diminishing the potential for tiredness. 2. The shape of the root canal is more conical, favoring a higher quality of the root canal filling, and increasing clinical success.

  14. El Niño Returns

    NASA Astrophysics Data System (ADS)

    El Niño, a climatic disturbance that shifts much of the world's weather pattern every 2-7 years, has returned and is probably near the midpoint of its expected 18-month life cycle, according to an announcement by the National Weather Service (NWS) of the National Oceanic and Atmospheric Administration (NOAA). This El Niño appears to be much milder than its predecessor 4 years ago, from April 1982 to July 1983. That event, the worst in more than 100 years, caused floods and droughts that led to more than 1000 deaths and $2 billion to $8 billion in economic losses.The phenomenon comes about when equatorial winds that normally blow the Pacific Ocean's surface waters from east to west weaken or reverse themselves. The warm surface waters then flow from west to east. Results include a decrease in rainfall in the Philippines, Indonesia, Australia, New Guinea, and Southern Africa; increased rainfall in the South American coast, the southeastern United States, and eastern Africa; and milder than normal weather in the U.S. Pacific Northwest, western Canada, and Alaska. The current El Niño was successfully predicted by at least three different scientific models, according to The New York Times, although the event began somewhat later than expected.

  15. Application of non-destructive impedance-based monitoring technique for cyclic fatigue evaluation of endodontic nickel-titanium rotary instruments.

    PubMed

    Chang, Yau-Zen; Liu, Mou-Chuan; Pai, Che-An; Lin, Chun-Li; Yen, Kuang-I

    2011-06-01

    This study investigates the application of non-destructive testing based on the impedance theory in the cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments. Fifty Ni-Ti ProTaper instruments were divided into five groups (n=10 in Groups A to E). Groups A to D were subjected to cyclic fatigue within an artificial canal (Group E was the control group). The mean value of the total life limit (TLL), defined as the instrument being rotated until fracture occurred was found to be 104 s in Group A. Each rotary instrument in Groups B, C and D were rotated until the tested instruments reached 80% (84 s), 60% (62 s) and 40% (42 s) of the TLL. After fatigue testing, each rotary instrument was mounted onto a custom-developed non-destructive testing device to give the tip of the instrument a progressive sideways bend in four mutually perpendicular directions to measure the corresponding impedance value (including the resistance and the reactance). The results indicated that the impedance value showed the same trend as the resistance, implying that the impedance was primarily affected by the resistance. The impedance value for the instruments in the 80% and 60% TLL groups increased by about 6 mΩ (about 7.5%) more than that of the instruments in the intact and 40% TLL groups. The SEM analysis result showed that crack striations were only found at the tip of the thread on the cracked surface of the instrument, consistent with the impedance measurements that found the impedance value of the cracked surface to be significantly different from those in other surfaces. These findings indicate that the impedance value may represent an effective parameter for evaluating the micro-structural status of Ni-Ti rotary instruments subjected to fatigue loading. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. In vitro resistance to fracture of two nickel-titanium rotary instruments made with different thermal treatments.

    PubMed

    Miccoli, Gabriele; Gaimari, Gianfranco; Seracchiani, Marco; Morese, Antonio; Khrenova, Tatyana; Di Nardo, Dario

    2017-01-01

    Aim of the study was to evaluate effectiveness of different heat treatments in improving Ni-Ti endodontic rotary instruments' resistance to fracture. 24 new NiTi instruments similar in length and shape: 12 M3 instruments, tip size 25 and .06 taper (United Dental, Shanghai, China), and 12 M3 Pro Gold instruments tip size 25 and .06 taper (United Dental, Shanghai, China), were tested in a 60° curved artificial root canal. Each group received a different heat treatment. Cycles to fracture were calculated for each instrument. Differences among groups were evaluated with an analysis of variance test (significance level was set at P<0.05.). Statistical analysis found significant differences (p<0.0213) between groups. The M3 Pro Gold instruments were significantly more resistant to fatigue (mean values = 1012, SD +/- 77) than M3 instruments (mean values = 748, SD +/- 62). No statistically significant differences were found between fragments' lengths (p>0,05). An increased flexibility and the reduction of internal defects produced by heat treatments during or after manufacturing processes, may be responsible for improving resistance to cyclic fatigue and flexural stresses.

  17. Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?

    PubMed

    Cheung, Gary S P; Shen, Ya; Darvell, Brian W

    2007-10-01

    The purpose of this study was to compare the low-cycle fatigue (LCF) behavior of electropolished and nonelectropolished nickel-titanium (NiTi) instruments of the same design in hypochlorite. Forty-five electropolished and 62 nonelectropolished NiTi engine files were subjected to rotational bending at various curvatures in 1.2% hypochlorite solution. Number of revolutions to failure, crack-initiation sites, extent of slow crack extension into the fracture cross-section, and surface-strain amplitude were noted. A linear relationship was found between LCF life and surface-strain amplitude for both groups, with no discernible difference between the two (p > 0.05). No electropolished instrument showed more than one crack origin, significantly fewer than for the nonelectropolished instruments (p < 0.05). The square root of crack extension and strain amplitude were inversely related. Although surface smoothness is enhanced by electropolishing, this did not protect the instrument from LCF failure.

  18. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments.

    PubMed

    Plotino, Gianluca; Costanzo, Alberto; Grande, Nicola M; Petrovic, Renata; Testarelli, Luca; Gambarini, Gianluca

    2012-02-01

    The purpose of this study was to evaluate the effect of autoclave sterilization on cyclic fatigue resistance of rotary endodontic instruments made of traditional and new nickel-titanium (NiTi) alloys. Four NiTi rotary endodontic instruments of the same size (tip diameter 0.40 mm and constant .04 taper) were selected: K3, Mtwo, Vortex, and K3 XF prototypes. Each group was then divided into 2 subgroups, unsterilized instruments and sterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve files from each different subgroup were tested for cyclic fatigue resistance. Means and standard deviations of number of cycles to failure (NCF) and fragment length of the fractured tip were calculated for each group, and data were statistically analyzed (P < .05). Comparing the results between unsterilized and sterilized instruments for each type of file, differences were statistically significant (P < .05) only between sterilized and unsterilized K3XF files (762 versus 651 NCF). The other instruments did not show significant differences (P > .05) in the mean NCF as a result of sterilization cycles (K3, 424 versus 439 NCF; Mtwo, 409 versus 419 NCF; Vortex, 454 versus 480 NCF). Comparing the results among the different groups, K3 XF (either sterilized or not) showed a mean NCF significantly higher than all other files (P < .05). Repeated cycles of autoclave sterilization do not seem to influence the mechanical properties of NiTi endodontic instruments except for the K3 XF prototypes of rotary instruments that demonstrated a significant increase of cyclic fatigue resistance. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. [Deformation evaluation of ProTaper nickel-titanium rotary instruments in curved canals instrumentation in vitro].

    PubMed

    Yan, Hong; Ren, Min; Yin, Xing-Zhe; Zhao, Shu-Yan; Zhang, Cheng-Fei

    2008-04-01

    To evaluate the deformation of ProTaper rotary instruments using in root canals of different curvature in vitro. Extracted first mandibular molars were divided into two experimental groups according to the curvature of mesial buccal canals: group A with moderate curvature and group B with severe curvature. Only the mesial buccal canals of all these teeth were prepared with 6 sets of new ProTaper rotary instruments individually. Additionally, the control group was established with a set of new ProTaper rotary instruments. After finishing each canal preparation, the instruments accompanied by control were examined under the stereomicroscope by an inspector without knowing the group. If distortion, unwinding, abrasion or fracture occurred within one set of instruments, then the whole set was disposed. The sets without problems were in use until 30 times. After 5, 10, 20 times canal preparation, S1, F1 files without deformation under stereomicroscope were examined under scanning electron microscope (SEM). Deformation of ProTaper rotary instruments happened after 12 times in group A and after 7 times in group B. In these two experimental groups, microcracks were found increasing with the times of use under SEM in the instruments without deformation under stereomicroscope. The microcracks on tip of instruments were deep in the early use and became smoother after 10 times. Similar changes happened on knife-edge of instruments, and the microcracks extended over the edge after 20 times use. Root canals with severe curvature tend to damage ProTaper rotary instruments more frequently than moderately curved canals. ProTaper rotary instruments are appropriate to treat less than 7 root canals with severe curvature or 12 root canals with moderate curvature. Stereomicroscope is recommended to detect early damages on Ni-Ti rotary instruments, for preventing instruments fracture in clinic.

  20. 32 CFR 21.665 - Nonprocurement instrument.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false Nonprocurement instrument. 21.665 Section 21.665 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.665 Nonprocurement instrument. A legal...

  1. 32 CFR 21.665 - Nonprocurement instrument.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 1 2012-07-01 2012-07-01 false Nonprocurement instrument. 21.665 Section 21.665 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.665 Nonprocurement instrument. A legal...

  2. 32 CFR 21.665 - Nonprocurement instrument.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 1 2013-07-01 2013-07-01 false Nonprocurement instrument. 21.665 Section 21.665 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.665 Nonprocurement instrument. A legal...

  3. 32 CFR 21.665 - Nonprocurement instrument.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Nonprocurement instrument. 21.665 Section 21.665 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.665 Nonprocurement instrument. A legal...

  4. 32 CFR 21.665 - Nonprocurement instrument.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 1 2014-07-01 2014-07-01 false Nonprocurement instrument. 21.665 Section 21.665 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.665 Nonprocurement instrument. A legal...

  5. A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests.

    PubMed

    Scelza, Pantaleo; Harry, Davidowicz; Silva, Licinio Esmeraldo da; Barbosa, Igor Bastos; Scelza, Miriam Zaccaro

    2015-01-01

    The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05). The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05). The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments' geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.

  6. Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization

    PubMed Central

    BULEM, Üreyen Kaya; KECECI, Ayse Diljin; GULDAS, Hilmi Egemen

    2013-01-01

    NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. Objective To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160). Material and Methods The instruments (n=10 for each subgroup) were dynamically immersed in NaOCl; immersed in NaOCl and sterilized in one autoclave cycle; 5 cycles immersed in NaOCl and sterilized in autoclave and not immersed in NaOCl and not sterilized (control group). Dynamic cyclic fatigue resistance was tested. The number of cycles to failure (NCF) were statistically analyzed (P<0.05). Results Kruskall-Wallis test indicated significant differences among the tested instruments in terms of NCF (P=0.000). The mean NCF of Mtwo (556.75) was higher than that of the Twisted File, Flexmaster and ProFile, 483.1, 376.12, 365.25, respectively. NaOCl immersion and autoclave sterilization have no effect on the NCF values of the tested instruments (P>.05). Conclusions Cyclic fatigue resistance of the tested NiTi instruments cannot be adversely affected by NaOCl immersion and autoclave sterilization. Production process (TwistedFiles) or design (Twisted Files, FlexMaster, Mtwo and ProFile) of the instruments can influence their cyclic fatigue resistance. PMID:24473715

  7. Effectiveness of supplementary irrigant agitation with the Finisher GF Brush on the debridement of oval root canals instrumented with the Gentlefile or nickel titanium rotary instruments.

    PubMed

    Neelakantan, P; Khan, K; Li, K Y; Shetty, H; Xi, W

    2018-07-01

    To examine the efficacy of a novel supplementary irrigant agitating brush (Finisher GF Brush, MedicNRG, Kibbutz Afikim, Israel) on the debridement of root canals prepared with a novel stainless steel rotary instrumentation system (Gentlefile; MedicNRG), or nickel titanium rotary instruments in oval root canals. Mandibular premolars (n = 72) were selected and divided randomly into three experimental groups (n = 24) after microCT scanning: group 1, canal preparation to rotary NiTi size 20, .04 taper (R20); group 2, rotary NiTi to size 25, .04 taper (R25) and group 3, Gentlefile size 23, .04 taper (GF). Specimens were subdivided into two subgroups: subgroup A, syringe-and-needle irrigation (SNI); subgroup B, Finisher GF Brush (GB). Ten untreated canals served as controls. Specimens were processed for histological evaluation, and the remaining pulp tissue (RPT) was measured. Data were analysed using Mann-Whitney and Kruskal-Wallis tests (P = 0.05). All experimental groups had significantly less RPT than the control (P < 0.05). Group 3B (GF-GB) had significantly less RPT than groups 1B (R20-GB) and 2B (R25-GF; P < 0.05). When irrigated with SNI, there was no significant difference in the RPT between the three groups (P > 0.05). When instrumented with R20, there was no significant difference between SNI and GF (P < 0.05) whilst GB had significantly less RPT than SNI for R25 (P < 0.05). Supplementary irrigant agitation with the Finisher GF Brush improved the debridement of canals prepared with Gentlefile and size 25, .04 taper rotary NiTi. Root canal debridement did not significantly differ between the instruments when syringe irrigation was used. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Influence of different manufacturing methods on the cyclic fatigue of rotary nickel-titanium endodontic instruments.

    PubMed

    Rodrigues, Renata C V; Lopes, Hélio P; Elias, Carlos N; Amaral, Georgiana; Vieira, Victor T L; De Martin, Alexandre S

    2011-11-01

    The aim of this study was to evaluate, by static and dynamic cyclic fatigue tests, the number of cycles to fracture (NCF) 2 types of rotary NiTi instruments: Twisted File (SybronEndo, Orange, CA), which is manufactured by a proprietary twisting process, and RaCe files (FKG Dentaire, La Chaux-de-Fonds, Switzerland), which are manufactured by grinding. Twenty Twisted Files (TFs) and 20 RaCe files #25/.006 taper instruments were allowed to rotate freely in an artificial curved canal at 310 rpm in a static or a dynamic model until fracture occurred. Measurements of the fractured fragments showed that fracture occurred at the point of maximum flexure in the midpoint of the curved segment. The NCF was significantly lower for RaCe instruments compared with TFs. The NCF was also lower for instruments subjected to the static test compared with the dynamic model in both groups. Scanning electron microscopic analysis revealed ductile morphologic characteristics on the fractured surfaces of all instruments and no plastic deformation in their helical shafts. Rotary NiTi endodontic instruments manufactured by twisting present greater resistance to cyclic fatigue compared with instruments manufactured by grinding. The fracture mode observed in all instruments was of the ductile type. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Cleaning capacity promoted by motor-driven or manual instrumentation using ProTaper Universal system: Histological analysis.

    PubMed

    da Frota, Matheus Franco; Filho, Idomeo Bonetti; Berbert, Fábio Luiz Camargo Villela; Sponchiado, Emilio Carlos; Marques, André Augusto Franco; Garcia, Lucas da Fonseca Roberti

    2013-01-01

    The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.

  10. Overview of the Neutron Radiography and Computed Tomography at the Oak Ridge National Laboratory and Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilheux, Hassina Z; Bilheux, Jean-Christophe; Tremsin, Anton S

    2015-01-01

    The Oak Ridge National Laboratory (ORNL) Neutron Sciences Directorate (NScD) has installed a neutron imaging (NI) beam line at the High Flux Isotope Reactor (HFIR) cold guide hall. The CG-1D beam line produces cold neutrons for a broad range of user research spanning from engineering to material research, additive manufacturing, vehicle technologies, archaeology, biology, and plant physiology. Recent efforts have focused on increasing flux and spatial resolution. A series of selected engineering applications is presented here. Historically and for more than four decades, neutron imaging (NI) facilities have been installed exclusively at continuous (i.e. reactor-based) neutron sources rather than atmore » pulsed sources. This is mainly due to (1) the limited number of accelerator-based facilities and therefore the fierce competition for beam lines with neutron scattering instruments, (2) the limited flux available at accelerator-based neutron sources and finally, (3) the lack of high efficiency imaging detector technology capable of time-stamping pulsed neutrons with sufficient time resolution. Recently completed high flux pulsed proton-driven neutron sources such as the ORNL Spallation Neutron Source (SNS) at ORNL and the Japanese Spallation Neutron Source (JSNS) of the Japan Proton Accelerator Research Complex (J-PARC) in Japan produce high neutron fluxes that offer new and unique opportunities for NI techniques. Pulsed-based neutron imaging facilities RADEN and IMAT are currently being built at J-PARC and the Rutherford National Laboratory in the U.K., respectively. ORNL is building a pulsed neutron imaging beam line called VENUS to respond to the U.S. based scientific community. A team composed of engineers, scientists and designers has developed a conceptual design of the future VENUS imaging instrument at the SNS.« less

  11. Evaluation of surface characteristics of rotary nickel-titanium instruments produced by different manufacturing methods.

    PubMed

    Inan, U; Gurel, M

    2017-02-01

    Instrument fracture is a serious concern in endodontic practice. The aim of this study was to investigate the surface quality of new and used rotary nickel-titanium (NiTi) instruments manufactured by the traditional grinding process and twisting methods. Total 16 instruments of two rotary NiTi systems were used in this study. Eight Twisted Files (TF) (SybronEndo, Orange, CA, USA) and 8 Mtwo (VDW, Munich, Germany) instruments were evaluated. New and used of 4 experimental groups were evaluated using an atomic force microscopy (AFM). New and used instruments were analyzed on 3 points along a 3 mm. section at the tip of the instrument. Quantitative measurements according to the topographical deviations were recorded. The data were statistically analyzed with paired samples t-test and independent samples t-test. Mean root mean square (RMS) values for new and used TF 25.06 files were 10.70 ± 2.80 nm and 21.58 ± 6.42 nm, respectively, and the difference between them was statistically significant (P < 0.05). Mean RMS values for new and used Mtwo 25.06 files were 24.16 ± 9.30 nm and 39.15 ± 16.20 nm respectively, the difference between them also was statistically significant (P < 0.05). According to the AFM analysis, instruments produced by twisting method (TF 25.06) had better surface quality than the instruments produced by traditional grinding process (Mtwo 25.06 files).

  12. Influence of rotational speed on the cyclic fatigue of rotary nickel-titanium endodontic instruments.

    PubMed

    Lopes, Hélio P; Ferreira, Alessandra A P; Elias, Carlos N; Moreira, Edson J L; de Oliveira, Júlio C Machado; Siqueira, José F

    2009-07-01

    During the preparation of curved canals, rotary nickel-titanium (NiTi) instruments are subjected to cyclic fatigue, which can lead to instrument fracture. Although several factors may influence the cyclic fatigue resistance of instruments, the role of the rotational speed remains uncertain. This study was intended to evaluate the effects of rotational speed on the number of cycles to fracture of rotary NiTi instruments. ProTaper Universal instruments F3 and F4 (Maillefer SA, Ballaigues, Switzerland) were used in an artificial curved canal under rotational speeds of 300 rpm or 600 rpm. The artificial canal was made of stainless steel, with an inner diameter of 1.5 mm, total length of 20 mm, and arc at the end with a curvature radius of 6 mm. The arc length was 9.4 mm and 10.6 mm on the straight part. The number of cycles required to fracture was recorded. Fractured surfaces and the helical shafts of the fractured instruments were analyzed by scanning electron microscopy. The results showed approximately a 30% reduction in the observed number of cycles to fracture as rotational speed was increased from 300 to 600 RPM (p < 0.05). The morphology of the fractured surface was always of ductile type, and no plastic deformation was observed on the helical shaft of fractured instruments. The present findings for both F3 and F4 ProTaper instruments revealed that the increase in rotational speed significantly reduced the number of cycles to fracture.

  13. A Ni(II) Bis(diphosphine)-Hydride Complex Containing Proton Relays - Structural Characterization and Electrocatalytic Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, Partha Pratim; Stolley, Ryan M.; Van Der Eide, Edwin F.

    The syntheses of the new 1,5-diphenyl-3,7-di(isopropyl)-1,5-diaza-3,7-diphosphacyclooctane ligand, PiPr2NPh2, is reported. The two equivalents of the ligand react with [Ni(CH3CN)6](BF4)2 to form the bis-diphosphine Ni(II)-complex [Ni(PiPr2NPh2)2](BF4)2, which acts as a proton reduction electrocatalyst. In addition to [Ni(PiPr2NPh2)2]2+, we report the syntheses and structural characterization of the Ni(0)-complex Ni(PiPr2NPh2)2, and the Ni(II)-hydride complex [HNi(PiPr2NPh2)2]BF4. The [HNi(PiPr2NPh2)2]BF4 complex represents the first Ni(II)-hydride in the [Ni(PR2NR'2)2]2+ family of compounds to be isolated and structurally characterized. In addition to the experimental data, the mechanism of electrocatalysis facilitated by [Ni(PiPr2NPh2)2]2+ is analyzed using linear free energy relationships recently established for the [Ni(PR2NR'2)2]2+ family. We thank Dr.more » Aaron Appel, Dr. Simone Raugei and Dr. Eric Wiedner for helpful discussions. This research was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Mass spectrometry was provided at W. R. Wiley Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by the Department of Energy’s office of Biological and Environmental Research located at Pacific Northwest National Laboratory. Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy.« less

  14. Stereomicroscopic evaluation of defects caused by torsional fatigue in used hand and rotary nickel-titanium instruments.

    PubMed

    Asthana, Geeta; Kapadwala, Marsrat I; Parmar, Girish J

    2016-01-01

    The aim of this study was to evaluate defects caused by torsional fatigue in used hand and rotary nickel-titanium (Ni-Ti) instruments by stereomicroscopic examination. One hundred five greater taper Ni-Ti instruments were used including Protaper universal hand (Dentsply Maillefer, Ballaigues, Switzerland), Protaper universal rotary (Dentsply Maillefer, Ballaigues, Switzerland), and Revo-S rotary (MicroMega, Besançon, France) files. Files were used on lower anterior teeth. After every use, the files were observed with both naked eyes and stereomicroscope at 20× magnification (Olympus, Shinjuku, Tokyo, Japan) to evaluate defects caused by torsional fatigue. Scoring was assigned to each file according to the degree of damage. The results were statistically analyzed using the Mann-Whitney U test and the Kruskal-Wallis test. A greater number of defects were seen under the stereomicroscope than on examining with naked eyes. However, the difference in methods of evaluation was not statistically significant. Revo-S files showed minimum defects, while Protaper universal hand showed maximum defects. The intergroup comparison of defects showed that the bend in Protaper universal hand instruments was statistically significant. Visible defects in Ni-Ti files due to torsional fatigue were seen by naked eyes as well as by stereomicroscope. This study emphasizes that all the files should be observed before and after every instrument cycle to minimize the risk of separation.

  15. A novel approach to determine the effect of irrigation on temperature and failure of Ni-Ti endodontic rotary files

    PubMed Central

    Mousavi, Sayed Ali; Kargar-Dehnavi, Vida; Mousavi, Sayed Amir

    2012-01-01

    Background: Nickel-titanium (Ni-Ti) rotary instrument files are important devices in Endodontics in root canal preparation. Ni-Ti file breakage is a critical and problematic issue and irrigation techniques were applied to decrease risk of file failure root. The aim of the present study was to compare the temperature gradient change of different irrigation solutions with Ni-Ti rotary instrument system during root canal preparation and also to define their effects on the file failure. Materials and Methods: A novel computerized instrumentation was utilized and thirty standard (ProFile #25/.04) files were divided into three groups and subjected to a filing in the root canal test. Changes in temperature on teeth under constant instrumental conditions with custom-designed computerized experimental apparatus were measured by using a temperature sensor bonded to the apical hole. A rotary instrument for canal preparation in three series of solution was used and the changes in temperature after each solution were compared. Finally, the file failure results were mentored according to each step of test. Comparisons were performed between group status clinically by using ANOVA (t) test, once the sample showed up normal and differences of P<0.01 were considered significant. All data collected were computerized and analyzed for frequency, distribution, and statistical description. Results: There was a decrease in the temperature of the instruments, which were immersed in 5% NaOCl, when compared with the water group (P<0.01). There was also a decrease in the temperature of the instruments immersed in water, when compared with the no solution group (P<0.01). Test results showed that sodium hypochlorite, water, or air of root canals does alter the properties of gradual temperature change and contributes to the failure of the instruments. Conclusion: By immersing the file in 5% NaOCl, the temperature gradient decreased and instrument failure was reduced. PMID:23087732

  16. Comprehensive theoretical studies on the low-lying electronic states of NiF, NiCl, NiBr, and NiI.

    PubMed

    Zou, Wenli; Liu, Wenjian

    2006-04-21

    The low-lying electronic states of the nickel monohalides, i.e., NiF, NiCl, NiBr, and NiI, are investigated by using multireference second-order perturbation theory with relativistic effects taken into account. For the energetically lowest 11 lambda-S states and 26 omega states there into, the potential energy curves and corresponding spectroscopic constants (vertical and adiabatic excitation energies, equilibrium bond lengths, vibrational frequencies, and rotational constants) are reported. The calculated results are grossly in very good agreement with those solid experimental data. In particular, the ground state of NiI is shown to be different from those of NiF, NiCl, and NiBr, being in line with the recent experimental observation. Detailed analyses are provided on those states that either have not been assigned or have been incorrectly assigned by previous experiments.

  17. Magnetism and charge density wave in GdNiC2 and NdNiC2

    NASA Astrophysics Data System (ADS)

    Klimczuk, Tom; Kolincio, Kamil; Wianiarski, Michal; Strychalska-Nowak, Judyta; Górnicka, Karolina

    The RNiC2 compounds form in an orthorhombic Amm2 crystal structure with Ni and the rare-earth (R) metal chains along the crystallographic a-axis. This system is of particular interest because both a CDW and a long range magnetic ordering phases have been observed together. We report the specific heat, magnetic, magnetotransport and galvanomagnetic properties of GdNiC2 and NdNiC2 antiferromagnets. Complex B-T phase diagrams were built based on the specific heat data. Large negative magnetoresistance due to Zeeman splitting of the electronic bands and partial destruction of a charge density wave ground state is observed above TN. The magnetoresistance and Hall measurements show that at low temperatures a magnetic field induced transformation from antiferromagnetic order to a metamagnetic phase results in the partial suppression of the CDW. This project is financially supported by National Science Centre (Poland), Grant Number: UMO-2015/19/B/ST3/03127.

  18. Root canal shaping with manual stainless steel files and rotary Ni-Ti files performed by students.

    PubMed

    Sonntag, D; Guntermann, A; Kim, S K; Stachniss, V

    2003-04-01

    To investigate root canal shaping with manual stainless steel files and rotary Ni-Ti files by students. Two hundred and ten simulated root canals with the same geometrical shape and size in acrylic resin blocks were prepared by 21 undergraduate dental students with manual stainless steel files using a stepback technique or with rotary Ni-Ti files in crown-down technique. Preparation length, canal shape, incidence of fracture and preparation time were investigated. Zips and elbows occurred significantly (P < 0.001) less frequently with rotary than with manual preparation. The correct preparation length was achieved significantly (P < 0.05) more often with rotary Ni-Ti files than with manual stainless steel files. Fractures occurred significantly (P < 0.05) less frequently with hand instrumentation. The mean time required for manual preparation was significantly (P < 0.001) longer than that required for rotary preparation. Prior experience with a hand preparation technique was not reflected in an improved quality of the subsequent engine-driven preparation. Inexperienced operators achieved better canal preparations with rotary Ni-Ti instruments than with manual stainless steel files. However, rotary preparation was associated with significantly more fractures.

  19. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture.

    PubMed

    Kim, Hyeon-Cheol; Lee, Min-Ho; Yum, Jiwan; Versluis, Antheunis; Lee, Chan-Joo; Kim, Byung-Min

    2010-07-01

    Nickel-titanium (NiTi) rotary files can produce cleanly tapered canal shapes with low tendency of transporting the canal lumen. Because NiTi instruments are generally perceived to have high fracture risk during use, new designs have been marketed to lower fracture risks. However, these design variations may also alter the forces on a root during instrumentation and increase dentinal defects that predispose a root to fracture. This study compared the stress conditions during rotary instrumentation in a curved root for three NiTi file designs. Stresses were calculated using finite element (FE) analysis. FE models of ProFile (Dentsply Maillefer, Ballaigues, Switzerland; U-shaped cross-section and constant 6% tapered shaft), ProTaper Universal (Dentsply; convex triangular cross-section with notch and progressive taper shaft), and LightSpeed LSX (Lightspeed Technology, Inc, San Antonio, TX; noncutting round shaft) were rotated within a curved root canal. The stress and strain conditions resulting from the simulated shaping action were evaluated in the apical root dentin. ProTaper Universal induced the highest von Mises stress concentration in the root dentin and had the highest tensile and compressive principal strain components at the external root surface. The calculated stress values from ProTaper Universal, which had the biggest taper shaft, approached the strength properties of dentin. LightSpeed generated the lowest stresses. The stiffer file designs generated higher stress concentrations in the apical root dentin during shaping of the curved canal, which raises the risk of dentinal defects that may lead to apical root cracking. Thus, stress levels during shaping and fracture susceptibility after shaping vary with instrument design. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Evaluation of the mechanical behaviour of PathFile and ProGlider pathfinding nickel-titanium rotary instruments.

    PubMed

    Elnaghy, A M; Elsaka, S E

    2015-09-01

    To assess and compare the resistance to cyclic fatigue, torsional stress, bending and buckling of ProGlider (PG; Dentsply Maillefer, Ballaigues, Switzerland) instruments with PathFile (PF; Dentsply Maillefer) pathfinding nickel-titanium rotary instruments. Size 16, .02 taper PG and PF instruments were rotated in simulated canals until failure, and the number of cycles to failure (NCF) was recorded to evaluate their cyclic fatigue resistance. Torsional strength was measured using a torsiometer after fixing rigidly the apical 5 mm of the instrument. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of the instruments. The instruments were evaluated for bending resistance using a cantilever-bending test. The buckling resistance was measured by recording the maximum load required to form a lateral elastic displacement along the file axis using a universal testing machine. Data were statistically analysed using independent t-tests. Statistical significance was set at P < 0.05. ProGlider instrument had a significantly higher flexibility, higher resistance to cyclic fatigue and torsional stress than PF instruments (P < 0.05). The fractured cross-sectional surfaces revealed typical features of cyclic fatigue and torsional fractures. There was no significant difference in the maximum load needed to buckle the two instruments tested (P = 0.082). ProGlider NiTi pathfinding instrument manufactured from M-Wire alloy had enhanced mechanical properties, including higher flexibility, higher resistance to cyclic fatigue and torsional stress compared with PathFile instrument made of conventional NiTi alloy. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  1. Flexibility and torsional behaviour of rotary nickel-titanium PathFile, RaCe ISO 10, Scout RaCe and stainless steel K-File hand instruments.

    PubMed

    Nakagawa, R K L; Alves, J L; Buono, V T L; Bahia, M G A

    2014-03-01

    To assess and compare the flexibility and torsional resistance of PathFile, RaCe ISO 10 and Scout RaCe instruments in relation to stainless steel K-File hand instruments. Rotary PathFile (sizes 13, 16 and 19; .02 taper), Race ISO 10 (size 10; 0.02, 0.04 and 0.06 tapers), Scout RaCe (sizes 10, 15 and 20; 0.02 taper) and hand K-File (sizes 10, 15 and 20; 0.02 taper) instruments were evaluated. Alloy chemical composition, phases present and transformation temperatures were determined for the NiTi instruments. For all instruments, diameters at each millimetre from the tip as well as cross-sectional areas at 3 mm from the tip were measured based on ANSI/ADA Specification No. 101 using image analysis software. Resistance to bending and torsional resistance were determined according to specification ISO 3630-1. Vickers microhardness measurements were also taken in all instruments to assess their strength. Data were analysed using analysis of variance (α = 0.05). The alloys used in the manufacture of the three types of NiTi instruments had approximately the same chemical composition, but the PathFile instruments had a higher Af transformation temperature and contained a small amount of B19' martensite. All instruments had diameter values within the standard tolerance. The bending and torsional resistance values were significantly increased relative to the instrument diameter and cross-sectional area. PathFile instruments were the most flexible and the least torque resistant, whilst the stainless steel instruments were the least flexible although they were more torque resistant than the NiTi instruments. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Phase transformation behavior and mechanical properties of thermomechanically treated K3XF nickel-titanium instruments.

    PubMed

    Shen, Ya; Zhou, Hui-Min; Wang, Zhejun; Campbell, Les; Zheng, Yu-feng; Haapasalo, Markus

    2013-07-01

    The bending and torsional properties of thermomechanically treated K3XF (SybronEndo, Orange, CA) nickel-titanium instruments in relation to their phase transformation behavior were evaluated. NiTi instruments K3 (SybronEndo) and K3XF, both in sizes 25/.04 and 40/.04, were examined by differential scanning calorimetry and X-ray diffraction. The metal composition was determined by scanning electron microscopy with X-ray energy-dispersive spectrometric analyses. The bending property of K3 and K3XF instruments was measured in a cantilever-bending test with a maximum deflection of 4.00 mm. A torsional test of the instruments was evaluated according to the American National Standards Institute/American Dental Association Specification No. 28. K3 and K3XF instruments had approximately the same chemical composition with a nickel content of 48-49 atomic %. The differential scanning calorimetry analyses showed that each segment of the K3XF instruments (24.89°C ± 1.98°C) had a higher austenite finish temperature than the K3 instruments (17.63°C ± 1.76°C) (P < .05). The bending load values were significantly lower for K3XF than for K3 in the superelastic ranges (P < .05). There was no statistically significant difference between K3 and K3XF in the maximum torque or maximum angular deflection before failure. The torque at fracture values of K3 and K3XF increased significantly with the diameter (P < .05). K3XF exhibited different phase transformation behavior and flexibility when compared with K3, which may be attributed to the special heat treatment history of K3XF instruments. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Analysis of the structure of climate networks under El Niño and La Niña conditions

    NASA Astrophysics Data System (ADS)

    Graciosa, Juan Carlos; Pastor, Marissa

    The El Niño-Southern Oscillation (ENSO) is the most important driver of natural climate variability and is characterized by anomalies in the sea surface temperatures (SST) over the tropical Pacific ocean. It has three phases: neutral, a warming phase or El Niño, and a cooling phase called La Niña. In this research, we modeled the climate under the three phases as a network and characterized its properties. We utilized the National Center for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) daily surface temperature reanalysis data from January 1950 to December 2016. A network associated to a month was created using the temperature spanning from the previous month to the succeeding month, for a total of three months worth of data for each network. Each site of the included data was a potential node in the network and the existence of links were determined by the strength of their relationship, which was based on mutual information. Interestingly, we found that climate networks exhibit small-world properties and these are found to be more prominent from October to April, coinciding with observations that El Niño occurrences peak from December to March. During these months, the temperature of a relatively large part of the Pacific ocean and its surrounding areas increase and the anomaly values become synchronized. This synchronization in the temperature anomalies forms links around the Pacific, increasing the clustering in the region and in effect, that of the entire network.

  4. Advanced Technologies and Instrumentation at the National Science Foundation

    NASA Astrophysics Data System (ADS)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  5. Stereomicroscopic evaluation of defects caused by torsional fatigue in used hand and rotary nickel-titanium instruments

    PubMed Central

    Asthana, Geeta; Kapadwala, Marsrat I.; Parmar, Girish J.

    2016-01-01

    Objective: The aim of this study was to evaluate defects caused by torsional fatigue in used hand and rotary nickel-titanium (Ni-Ti) instruments by stereomicroscopic examination. Materials and Methods: One hundred five greater taper Ni-Ti instruments were used including Protaper universal hand (Dentsply Maillefer, Ballaigues, Switzerland), Protaper universal rotary (Dentsply Maillefer, Ballaigues, Switzerland), and Revo-S rotary (MicroMega, Besançon, France) files. Files were used on lower anterior teeth. After every use, the files were observed with both naked eyes and stereomicroscope at 20× magnification (Olympus, Shinjuku, Tokyo, Japan) to evaluate defects caused by torsional fatigue. Scoring was assigned to each file according to the degree of damage. Statistics: The results were statistically analyzed using the Mann-Whitney U test and the Kruskal-Wallis test. Results: A greater number of defects were seen under the stereomicroscope than on examining with naked eyes. However, the difference in methods of evaluation was not statistically significant. Revo-S files showed minimum defects, while Protaper universal hand showed maximum defects. The intergroup comparison of defects showed that the bend in Protaper universal hand instruments was statistically significant. Conclusion: Visible defects in Ni-Ti files due to torsional fatigue were seen by naked eyes as well as by stereomicroscope. This study emphasizes that all the files should be observed before and after every instrument cycle to minimize the risk of separation. PMID:27099415

  6. Preparation and characterization of Ni based on natural zeolite catalyst for citronellol conversion to 3,7-Dimethyl-1-Octanol

    NASA Astrophysics Data System (ADS)

    Sudiyarmanto, Hidayati, Luthfiana N.; Kristiani, Anis; Ghaisani, Almira; Sukandar, Dede; Adilina, Indri B.; Tursiloadi, Silvester

    2017-11-01

    Citronella oil is a kind of essential oil that contains three main components, namely citronellal, citronellol, and geraniol. The high demand of citronellal and geraniol derivative prompted scientists to develop methods which are stereo-selective synthesis. A hydrogenation reaction using heterogeneous catalyst is one way of synthesis of citronella oil derivatives. In this research, synthesis of citronellol oil derivatives using Ni based on natural zeolite (Ni/ZAB) catalyst which is expected to produce the compound of 3,7-dimethyl-1-octanol. The catalyst was prepared by supporting Ni on natural zeolite by impregnation method. The physical and chemical properties of Ni/ZAB catalyst have been characterized by TGA, BET, XRD and FTIR instrumentations. Variation of pressure and temperature reactions were conducted to determine the optimum conditions for the hydrogenation of citronellol. The products from this reaction were analyzed using GC-MS instrumentation. The yield and selectivity of 3,7-dimethyl-1-octanol compound were achieved with optimum conditions at 200°C and 20 bar during 3 hours which produced around 51.97% and 47.81% respectively.

  7. The Defense Colombian Sovereignty at the Guajira Peninsula, through the Integration of the Instruments of National Power

    DTIC Science & Technology

    2016-06-10

    demands and physical intrusions on Colombian territory and is attempting to provoke a military conflict with Colombia. The Venezuelan government is...corrupt administration. A change in the Venezuelan government does not mean that aggressive intentions have been reduced. As an example, the...Colombia. This study first describes the instruments of national power as United States government doctrine and then proposes the application of these

  8. Physical and Mechanical Properties of LoVAR: A New Lightweight Particle-Reinforced Fe-36Ni Alloy

    NASA Technical Reports Server (NTRS)

    Stephenson, Timothy; Tricker, David; Tarrant, Andrew; Michel, Robert; Clune, Jason

    2015-01-01

    Fe-36Ni is an alloy of choice for low thermal expansion coefficient (CTE) for optical, instrument and electrical applications in particular where dimensional stability is critical. This paper outlines the development of a particle-reinforced Fe-36Ni alloy that offers reduced density and lower CTE compared to the matrix alloy. A summary of processing capability will be given relating the composition and microstructure to mechanical and physical properties.

  9. The Niño1+2 region and the Niño4 region predictability.

    NASA Astrophysics Data System (ADS)

    Miguel, Tasambay-Salazar; Jose, Ortizbevia Maria; Francisco Jose, Alvarez-Garcia; Antonio, Ruizdeelvira

    2016-04-01

    The El Niño-Southern Oscillation variability is monitored basically by the the Niño3.4 Index. In addition, the Niño1+2 and the Niño4 Indexes are also used to characterise ENSO variability, by reason of their relationships with some of the variability of the neighboring regions, like the air temperature in South America or Australia. However, with the increased length of the available instrumental ENSO records, the need of considering the two different ENSO types identified, Eastern Pacific (EP) or Central Pacific (CP), has become more evident. (Yu and Kim 2013). While the Nino3.4 Index is used to monitor the EP events, the CP events are currently identified by removing from the Niño4 Index the variability associated to the Niño1+2 Index (Kao and Yu 2009). Therefore there is a renewed interest on the predictability of both Indexes. In this study we focus on the predictability of the Niño1+2 region variability and those of the Niño4 region, in the recent post-satellital period. We develop a methodology to identify potential predictors among climate modes, represented by their respective indexes. Among the tropical predictors tested we include the most commonly used,like the Southern Oscillation Index or the Warm Water Volume in the equatorial Pacific (WWV) Index, but also some whose part in the ENSO generation and evolution has been pointed only recently, like the Pacific Meridional Mode (PMM) Index or the North Tropical Zonal Gradient and South Tropical Zonal Gradient Indexes.We also include in our study some other tropical Indexes outside the Pacific basin, like the Tropical North Atlantic, the Tropical South Atlantic and the Indian Ocean Dipole Indexes. We use a seasonal approach, based in a linear statistical relationship and focus on leads going from one season to one year. In the case of the Niño1+2 Index, the number of potential predictors is much higher in spring, followed by winter and summer and last of all autumn. The potential predictor most

  10. MLS measurements of stratospheric hydrogen cyanide during the 2015-2016 El Niño event

    NASA Astrophysics Data System (ADS)

    Pumphrey, Hugh C.; Glatthor, Norbert; Bernath, Peter F.; Boone, Christopher D.; Hannigan, James W.; Ortega, Ivan; Livesey, Nathaniel J.; Read, William G.

    2018-01-01

    It is known from ground-based measurements made during the 1982-1983 and 1997-1998 El Niño events that atmospheric hydrogen cyanide (HCN) tends to be higher during such years than at other times. The Microwave Limb Sounder (MLS) on the Aura satellite has been measuring HCN mixing ratios since launch in 2004; the measurements are ongoing at the time of writing. The winter of 2015-2016 saw the largest El Niño event since 1997-1998. We present MLS measurements of HCN in the lower stratosphere for the Aura mission to date, comparing the 2015-2016 El Niño period to the rest of the mission. HCN in 2015-2016 is higher than at any other time during the mission, but ground-based measurements suggest that it may have been even more elevated in 1997-1998. As the MLS HCN data are essentially unvalidated, we show them alongside data from the MIPAS and ACE-FTS instruments; the three instruments agree reasonably well in the tropical lower stratosphere. Global HCN emissions calculated from the Global Fire Emissions Database (GFED v4.1) database are much greater during large El Niño events and are greater in 1997-1998 than in 2015-2016, thereby showing good qualitative agreement with the measurements. Correlation between El Niño-Southern Oscillation (ENSO) indices, measured HCN, and GFED HCN emissions is less clear if the 2015-2016 event is excluded. In particular, the 2009-2010 winter had fairly strong El Niño conditions and fairly large GFED HCN emissions, but very little effect is observed in the MLS HCN.

  11. Volumetric analysis of hand, reciprocating and rotary instrumentation techniques in primary molars using spiral computed tomography: An in vitro comparative study.

    PubMed

    Jeevanandan, Ganesh; Thomas, Eapen

    2018-01-01

    This present study was conducted to analyze the volumetric change in the root canal space and instrumentation time between hand files, hand files in reciprocating motion, and three rotary files in primary molars. One hundred primary mandibular molars were randomly allotted to one of the five groups. Instrumentation was done using Group I; nickel-titanium (Ni-Ti) hand file, Group II; Ni-Ti hand files in reciprocating motion, Group III; Race rotary files, Group IV; prodesign pediatric rotary files, and Group V; ProTaper rotary files. The mean volumetric changes were assessed using pre- and post-operative spiral computed tomography scans. Instrumentation time was recorded. Statistical analysis to access intergroup comparison for mean canal volume and instrumentation time was done using Bonferroni-adjusted Mann-Whitney test and Mann-Whitney test, respectively. Intergroup comparison of mean canal volume showed statistically significant difference between Groups II versus IV, Groups III versus V, and Groups IV versus V. Intergroup comparison of mean instrumentation time showed statistically significant difference among all the groups except Groups IV versus V. Among the various instrumentation techniques available, rotary instrumentation is the considered to be the better instrumentation technique for canal preparation in primary teeth.

  12. Smart instruments and the national collaboratory

    NASA Technical Reports Server (NTRS)

    Leiner, Barry M. (Editor)

    1989-01-01

    Here, we explore the process of scientific experimental investigation and ask what capabilities are required of the collaboratory to support such investigations. We first look at a number of examples of scientific research being conducted using remote instruments. We then examine the process of such research, asking at each stage what are the required capabilities. We finally integrate these results into a statement of the required set of capabilities needed to support scientific research in the future.

  13. First principles exploration of NiO and its ions NiO+ and NiO-

    NASA Astrophysics Data System (ADS)

    Sakellaris, Constantine N.; Mavridis, Aristides

    2013-02-01

    We present a high level ab initio study of NiO and its ions, NiO+ and NiO-. Employing variational multireference configuration interaction (MRCI) and single reference coupled-cluster methods combined with basis sets of quintuple quality, 54, 20, and 10 bound states of NiO, NiO+, and NiO- have been studied. For all these states, complete potential energy curves have been constructed at the MRCI level of theory; in addition, for the ground states of the three species core subvalence (3s23p6/Ni) and scalar relativistic effects have been taken into account. We report energetics, spectroscopic parameters, dipole moments, and spin-orbit coupling constants. The agreement with experiment is in the case of NiO good, but certain discrepancies that need further investigation have arisen in the case of the anion whose ground state remains computationally a tantalizing matter. The cation is experimentally almost entirely unexplored, therefore, the study of many states shall prove valuable to further investigators. The ground state symmetry, bond distances, and binding energies of NiO and NiO+ are (existing experimental values in parenthesis), X3Σ-(X3Σ-), re = 1.606 (1.62712) Å, D0 = 88.5 (89.2 ± 0.7) kcal/mol, and X4Σ-(?), re = 1.60(?) Å, D0 = 55 (62.4 ± 2.4) kcal/mol, respectively. The ground state of NiO- is 4Σ- (but 2Π experimentally) with D0 = 85-87 (89.2 ± 0.7) kcal/mol.

  14. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  15. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  16. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  17. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  18. Chris Cantrell and Becky Anderson of the National Center for Atmospheric Research assess the CIMS instrument's operation during ARCTAS mission preparations

    NASA Image and Video Library

    2008-03-07

    Climate researchers from the National Center for Atmospheric Research (NCAR) and several universities install and perform functional checkouts of a variety of sensitive atmospheric instruments on NASA's DC-8 airborne laboratory prior to beginning the ARCTAS mission.

  19. Fast Response Shape Memory Effect Titanium Nickel (TiNi) Foam Torque Tubes

    NASA Technical Reports Server (NTRS)

    Jardine, Peter

    2014-01-01

    Shape Change Technologies has developed a process to manufacture net-shaped TiNi foam torque tubes that demonstrate the shape memory effect. The torque tubes dramatically reduce response time by a factor of 10. This Phase II project matured the actuator technology by rigorously characterizing the process to optimize the quality of the TiNi and developing a set of metrics to provide ISO 9002 quality assurance. A laboratory virtual instrument engineering workbench (LabVIEW'TM')-based, real-time control of the torsional actuators was developed. These actuators were developed with The Boeing Company for aerospace applications.

  20. Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments.

    PubMed

    Braga, Lígia Carolina Moreira; Faria Silva, Ana Cristina; Buono, Vicente Tadeu Lopes; de Azevedo Bahia, Maria Guiomar

    2014-09-01

    The aim of this study was to assess the influence of M-Wire (Dentsply Tulsa Dental Specialties, Tulsa, OK) and controlled memory technologies on the fatigue resistance of rotary nickel-titanium (NiTi) files by comparing files made using these 2 technologies with conventional NiTi files. Files with a similar cross-sectional design and diameter were chosen for the study: new 30/.06 files of the EndoWave (EW; J. Morita Corp, Osaka, Japan), HyFlex (HF; Coltene/Whaledent, Inc, Cuyahoga Falls, OH), ProFile Vortex (PV; Dentsply Tulsa Dental Specialties, Tulsa, OK), and Typhoon (TYP; Clinician's Choice Dental Products, New Milford, CT) systems together with ProTaper Universal F2 instruments (PTU F2; Dentsply Maillefer, Ballaigues, Switzerland). The compositions and transformation temperatures of the instruments were analyzed using x-ray energy-dispersive spectroscopy and differential scanning calorimetry, whereas the mean file diameter values at 3 mm from the tip (D3) were measured using image analysis software. The average number of cycles to failure was determined using a fatigue test device. X-ray energy-dispersive spectroscopy analysis showed that, on average, all the instruments exhibited the same chemical composition, namely, 51% Ni-49% Ti. The PV, TYP, and HF files exhibited increased transformation temperatures. The PTU F2, PV, and TYP files had similar D3 values, which were less than those of the EW and HF files. The average number of cycles to failure values were 150% higher for the TYP files compared with the PV files and 390% higher for the HF files compared with the EW files. M-Wire and controlled memory technologies increase the fatigue resistance of rotary NiTi files. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. The oxidation of Ni-rich Ni-Al intermetallics

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph; Smialek, James L.; Barrett, Charles A.

    1988-01-01

    The oxidation of Ni-Al intermetallic alloys in the beta-NiAl phase field and in the two phase beta-NiAl/gamma'-Ni3Al phase field has been studied between 1000 and 1400 C. The stoichiometric beta-NiAl alloy doped with Zr was superior to other alloy compositions under cyclic and isothermal oxidation. The isothermal growth rates did not increase monotonically as the alloy Al content was decreased. The characteristically ridged alpha-Al2O3 scale morphology, consisting of cells of thin, textured oxide with thick growth ridges at cell boundaries, forms on oxidized beta-NiAl alloys. The correlation of scale features with isothermal growth rates indicates a predominant grain boundary diffusion growth mechanism. The 1200 C cyclic oxidation resistance decreases near the lower end of the beta-NiAl phase field.

  2. Foramen Changes following Over Instrumentation of Curved Canals with Three Engine-Driven Instruments: An In Vitro Study

    PubMed Central

    Yammine, Salwa; Jabbour, Edgard; Nahas, Paul; Majzoub, Zeina

    2017-01-01

    Introduction: The present in vitro study aimed to evaluate and compare the changes in shape and surface area of the major foramen following shaping of curved canals with three new generation NiTi engine-driven instruments naming ProTaper Next, BT RaCe and WaveOne Gold- with 3 different levels of protrusion beyond the major apical foramen. Methods and Materials: A total of 45 extracted human molars with at least one curved canal were distributed in 3 comparable groups of 15 that were instrumented using either ProTaper Next (PTN), BT RaCe (BTR) or WaveOne Gold (WOG). The canals were instrumented to the major foramen and then over instrumented with the final file 0.5 mm, 1 mm and 1.5 mm beyond the foramen. Standardized pre- and post-instrumentation photographs of the foramen were obtained for all groups using a stereomicroscope. Foramen shape and surface area were evaluated using the AmScope software for measurements and compared between groups and levels of instrumentation applying binary conditional logistic regression and repeated measures ANOVA. The level of significance was set at 0.05. Results: Foramen shape tended to gradually change from circular to oval as the level of instrumentation increased in all groups. The original foramen shape in WOG group remained better than other groups. Foramen surface areas increased in all groups with Group BTR demonstrating significantly greater values than the other 2 groups. Conclusion: Over instrumentation resulted in apical enlargement and ovalization in all 3 groups but with different patterns. These differences can be attributed to the final file size, design characteristics and kinematics of the 3 systems. PMID:29225641

  3. Foramen Changes following Over Instrumentation of Curved Canals with Three Engine-Driven Instruments: An In Vitro Study.

    PubMed

    Yammine, Salwa; Jabbour, Edgard; Nahas, Paul; Majzoub, Zeina

    2017-01-01

    The present in vitro study aimed to evaluate and compare the changes in shape and surface area of the major foramen following shaping of curved canals with three new generation NiTi engine-driven instruments naming ProTaper Next, BT RaCe and WaveOne Gold- with 3 different levels of protrusion beyond the major apical foramen. A total of 45 extracted human molars with at least one curved canal were distributed in 3 comparable groups of 15 that were instrumented using either ProTaper Next (PTN), BT RaCe (BTR) or WaveOne Gold (WOG). The canals were instrumented to the major foramen and then over instrumented with the final file 0.5 mm, 1 mm and 1.5 mm beyond the foramen. Standardized pre- and post-instrumentation photographs of the foramen were obtained for all groups using a stereomicroscope. Foramen shape and surface area were evaluated using the AmScope software for measurements and compared between groups and levels of instrumentation applying binary conditional logistic regression and repeated measures ANOVA. The level of significance was set at 0.05. Foramen shape tended to gradually change from circular to oval as the level of instrumentation increased in all groups. The original foramen shape in WOG group remained better than other groups. Foramen surface areas increased in all groups with Group BTR demonstrating significantly greater values than the other 2 groups. Over instrumentation resulted in apical enlargement and ovalization in all 3 groups but with different patterns. These differences can be attributed to the final file size, design characteristics and kinematics of the 3 systems.

  4. Direct Experimental Probe of the Ni(II)/Ni(III)/Ni(IV) Redox Evolution in LiNi 0.5Mn 1.5O 4 Electrodes

    DOE PAGES

    Qiao, Ruimin; Wray, L. Andrew; Kim, Jung -Hyun; ...

    2015-11-11

    The LiNi 0.5Mn 1.5O 4 spinel is an appealing cathode material for next generation rechargeable Li-ion batteries due to its high operating voltage of ~4.7 V (vs Li/Li +). Although it is widely believed that the full range of electrochemical cycling involves the redox of Ni(II)/(IV), it has not been experimentally clarified whether Ni(III) exists as the intermediate state or a double-electron transfer takes place. Here, combined with theoretical calculations, we show unambiguous spectroscopic evidence of the Ni(III) state when the LiNi 0.5Mn 1.5O 4 electrode is half charged. This provides a direct verification of single-electron-transfer reactions in LiNi 0.5Mnmore » 1.5O 4 upon cycling, namely, from Ni(II) to Ni(III), then to Ni(IV). Additionally, by virtue of its surface sensitivity, soft X-ray absorption spectroscopy also reveals the electrochemically inactive Ni 2+ and Mn 2+ phases on the electrode surface. Our work provides the long-awaited clarification of the single-electron transfer mechanism in LiNi 0.5Mn 1.5O 4 electrodes. Furthermore, the experimental results serve as a benchmark for further spectroscopic characterizations of Ni-based battery electrodes.« less

  5. The TMT instrumentation program

    NASA Astrophysics Data System (ADS)

    Simard, Luc; Crampton, David; Ellerbroek, Brent; Boyer, Corinne

    2010-07-01

    An overview of the current status of the Thirty Meter Telescope (TMT) instrumentation program is presented. Conceptual designs for the three first light instruments (IRIS, WFOS and IRMS) are in progress, as well as feasibility studies of MIRES. Considerable effort is underway to understand the end-to-end performance of the complete telescopeadaptive optics-instrument system under realistic conditions on Mauna Kea. Highly efficient operation is being designed into the TMT system, based on a detailed investigation of the observation workflow to ensure very fast target acquisition and set up of all subsystems. Future TMT instruments will almost certainly involve contributions from institutions in many different locations in North America and partner nations. Coordinating and optimizing the design and construction of the instruments to ensure delivery of the best possible scientific capabilities is an interesting challenge. TMT welcomes involvement from all interested instrument teams.

  6. 77 FR 32942 - Application(s) for Duty-Free Entry of Scientific Instruments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-04

    .... Intended Use: The instrument will be used to fabricate bulk nanostructured metals and metallic glasses, in particular Mg based alloys, CuNb, NiAl, Nb based alloys and metal matrix composites with oxide nanoparticles... oxide nanoparticles during the melting of metals. Suction casting is required to achieve nanocrystalline...

  7. Interdecadal modulation of El Niño teleconnection on monsoon Asia climate over the past five centuries

    NASA Astrophysics Data System (ADS)

    Li, J.; Xie, S. P.

    2017-12-01

    The El Niño influence on monsoon Asia climate weakened during the mid-20th century and strenthened substantially after the late 1970s. Exploring the nature of such an interdecadal variation is constrained by short instrumental records. Here we synthesize the Indo-Pacific tree-rings and coral records to reconstruct monsoon Asia temperature and moisture change during the past five centuries, and show that the interdecadal modulation of El Niño teleconnection on monsoon Asia climate is a robust feature beyond the instrumenal era. Comparison with proxy El Niño records indicates that the El Niño-monsoon Asia climate teleconnection is controlled by interdecadal changes in ENSO variance, with strong (weak) teleconnection in periods of high (low) variance, respectively.

  8. A reconstructed computerized tomographic comparison of Ni-Ti rotary GT files versus traditional instruments in canals shaped by novice operators.

    PubMed

    Gluskin, A H; Brown, D C; Buchanan, L S

    2001-09-01

    The aim of this study was to compare the effects of preparation with conventional stainless steel Flexofiles and Gates Glidden burs versus nickel-titanium GT rotary files in the shaping of mesial root canals of extracted mandibular molars. A total of 54 canals from 27 mesial roots of mandibular molar teeth were prepared using one of two methods by novice dental students. One canal in each root was prepared by a crown-down approach. utilizing stainless steel Flexofiles and Gates Glidden burs. The other canal was prepared using nickel-titanium GT rotary files in a crown-down fashion as recommended by the manufacturer. Preoperative CT scans of each root were recorded and 50 canal specimens were available for postoperative comparisons. Following canal shaping, postoperative scans were superimposed on the original images. Changes in canal area, canal transportation and thickness of remaining root structure at strategic levels of the root were analyzed. The time taken for each method was also noted. At the coronal and mid-root coronal one-third sections, the rotary GT files produced a significantly smaller postoperative canal area (P < 0.05). In the mid-root sections there was significantly less transportation of the root canal toward the furcation, and less thinning of the root structure with GT files compared to the stainless steel files (P < 0.05). Overall, there was greater conservation of structure coronally and more adequate shape in the mid-root level. The GT rotary technique was significantly faster than the stainless steel hand-held file technique (P < 0.0001). Two GT instruments fractured during the study. Under the conditions of this study, novice dental students were able to prepare curved root canals with Ni-Ti GT rotary files with less transportation and greater conservation of tooth structure, compared to canals prepared with hand instruments. The rotary technique was significantly faster.

  9. Uncertainty in regional temperatures inferred from sparse global observations: Application to a probabilistic classification of El Niño

    NASA Astrophysics Data System (ADS)

    Ilyas, Maryam; Brierley, Christopher M.; Guillas, Serge

    2017-09-01

    Instrumental records showing increases in surface temperature are some of the robust and iconic evidence of climate change. But how much should we trust regional temperature estimates interpolated from sparse observations? Here we quantify the uncertainty in the instrumental record by applying multiresolution lattice kriging, a recently developed interpolation technique that leverages the multiple spatial scales of temperature anomalies. The probability of monthly anomalies across the globe is represented by an ensemble, based on HadCRUT4 and accounting for observational and coverage uncertainties. To demonstrate the potential of these new data, we investigate the area-averaged temperature anomalies over the Niño 3.4 region in the equatorial Pacific. Having developed a definition of the El Niño-Southern Oscillation (ENSO) able to cope with probability distribution functions, we classify the ENSO state for each year since 1851. We find that for many years it is ambiguous as to whether there was an El Niño or not from the Niño 3.4 region alone. These years are mainly before 1920, but also just after World War II.

  10. Development of B2 Shape Memory Intermetallics Beyond NiAl, CoNiAl and CoNiGa

    NASA Astrophysics Data System (ADS)

    Gerstein, G.; Firstov, G. S.; Kosorukova, T. A.; Koval, Yu. N.; Maier, H. J.

    2018-06-01

    The present study describes the development of shape memory alloys based on NiAl. Initially, this system was considered a promising but unsuccessful neighbour of NiTi. Later, however, shape memory alloys like CoNiAl or CoNiGa were developed that can be considered as NiAl derivatives and already demonstrated good mechanical properties. Yet, these alloys were still inferior to NiTi in most respects. Lately, using a multi-component approach, a CoNiCuAlGaIn high entropy intermetallic compound was developed from the NiAl prototype. This new alloy featured a B2 phase and a martensitic transformation along with a remarkable strength in the as-cast state. In the long-term, this new approach might led to a breakthrough for shape memory alloys in general.

  11. Point defect evolution in Ni, NiFe and NiCr alloys from atomistic simulations and irradiation experiments

    DOE PAGES

    Aidhy, Dilpuneet S.; Lu, Chenyang; Jin, Ke; ...

    2015-08-08

    Using molecular dynamics simulations, we elucidate irradiation-induced point defect evolution in fcc pure Ni, Ni 0.5Fe 0.5, and Ni 0.8Cr 0.2 solid solution alloys. We find that irradiation-induced interstitials form dislocation loops that are of 1/3 <111>{111}-type, consistent with our experimental results. While the loops are formed in all the three materials, the kinetics of formation is considerably slower in NiFe and NiCr than in pure Ni, indicating that defect migration barriers and extended defect formation energies could be higher in the alloys than pure Ni. As a result, while larger size clusters are formed in pure Ni, smaller andmore » more clusters are observed in the alloys. The vacancy diffusion occurs at relatively higher temperatures than interstitials, and their clustering leads to formation of stacking fault tetrahedra, also consistent with our experiments. The results also show that the surviving Frenkel pairs are composition-dependent and are largely Ni dominated.« less

  12. Thermally Induced Interdiffusion and Precipitation in a Ni/Ni 3 Al System

    DOE PAGES

    Sun, C.; Martinez, E.; Aguiar, J. A.; ...

    2015-05-20

    Ordered Ni 3Al intermetallic precipitates constitute the main hardening sources of Ni-based superalloys. Here, we report the interdiffusion and precipitation behavior in a Ni/Ni3Al model system. The deposition of Ni3Al on a pure Ni layer at 500°C generated L12-structured γ' (Ni3Al) precipitates, preferentially at the interface. After annealing at 800°C for 1 h, interdiffusion between Ni and Ni3Al layers occurred, and the γ' precipitates that grew near the parent Ni/Ni 3Al interface are ~2.8 times larger in size than those formed in the matrix. In conclusion, Monte Carlo simulations indicate that vacancies preferentially diffuse along the Ni/Ni 3Al interface, increasingmore » the probability of precipitation.« less

  13. A Threonine Stabilizes the NiC and NiR Catalytic Intermediates of [NiFe]-hydrogenase*

    PubMed Central

    Abou-Hamdan, Abbas; Ceccaldi, Pierre; Lebrette, Hugo; Gutiérrez-Sanz, Oscar; Richaud, Pierre; Cournac, Laurent; Guigliarelli, Bruno; De Lacey, Antonio L.; Léger, Christophe; Volbeda, Anne; Burlat, Bénédicte; Dementin, Sébastien

    2015-01-01

    The heterodimeric [NiFe] hydrogenase from Desulfovibrio fructosovorans catalyzes the reversible oxidation of H2 into protons and electrons. The catalytic intermediates have been attributed to forms of the active site (NiSI, NiR, and NiC) detected using spectroscopic methods under potentiometric but non-catalytic conditions. Here, we produced variants by replacing the conserved Thr-18 residue in the small subunit with Ser, Val, Gln, Gly, or Asp, and we analyzed the effects of these mutations on the kinetic (H2 oxidation, H2 production, and H/D exchange), spectroscopic (IR, EPR), and structural properties of the enzyme. The mutations disrupt the H-bond network in the crystals and have a strong effect on H2 oxidation and H2 production turnover rates. However, the absence of correlation between activity and rate of H/D exchange in the series of variants suggests that the alcoholic group of Thr-18 is not necessarily a proton relay. Instead, the correlation between H2 oxidation and production activity and the detection of the NiC species in reduced samples confirms that NiC is a catalytic intermediate and suggests that Thr-18 is important to stabilize the local protein structure of the active site ensuring fast NiSI-NiC-NiR interconversions during H2 oxidation/production. PMID:25666617

  14. A threonine stabilizes the NiC and NiR catalytic intermediates of [NiFe]-hydrogenase.

    PubMed

    Abou-Hamdan, Abbas; Ceccaldi, Pierre; Lebrette, Hugo; Gutiérrez-Sanz, Oscar; Richaud, Pierre; Cournac, Laurent; Guigliarelli, Bruno; De Lacey, Antonio L; Léger, Christophe; Volbeda, Anne; Burlat, Bénédicte; Dementin, Sébastien

    2015-03-27

    The heterodimeric [NiFe] hydrogenase from Desulfovibrio fructosovorans catalyzes the reversible oxidation of H2 into protons and electrons. The catalytic intermediates have been attributed to forms of the active site (NiSI, NiR, and NiC) detected using spectroscopic methods under potentiometric but non-catalytic conditions. Here, we produced variants by replacing the conserved Thr-18 residue in the small subunit with Ser, Val, Gln, Gly, or Asp, and we analyzed the effects of these mutations on the kinetic (H2 oxidation, H2 production, and H/D exchange), spectroscopic (IR, EPR), and structural properties of the enzyme. The mutations disrupt the H-bond network in the crystals and have a strong effect on H2 oxidation and H2 production turnover rates. However, the absence of correlation between activity and rate of H/D exchange in the series of variants suggests that the alcoholic group of Thr-18 is not necessarily a proton relay. Instead, the correlation between H2 oxidation and production activity and the detection of the NiC species in reduced samples confirms that NiC is a catalytic intermediate and suggests that Thr-18 is important to stabilize the local protein structure of the active site ensuring fast NiSI-NiC-NiR interconversions during H2 oxidation/production. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  15. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    PubMed

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits < θ < 0.27 logits) with a reliability of 0.9. Only the changing position item demonstrated misfit (χ 2  = 36.6, df = 17, p = 0.0038), and the dressing item demonstrated DIF on the impairment type (upper extremity/others, McFadden's Pseudo R 2  > 5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  16. El Niño rides again

    NASA Astrophysics Data System (ADS)

    Friebele, Elaine

    Another weather-disrupting El Niño may be brewing in the Pacific Ocean, according to ocean measurements taken by NASA instruments on two orbiting satellites. Sea-surface height measurements taken by the radar altimeter on board the joint U.S.-French TOPEX/Poseidon satellite and wind data collected by the NASA scatterometer on Japan's Advanced Earth Observing Satellite (ADEOS) have been used together for the first time to predict changing weather conditions in the tropical Pacific Ocean.El Niño occurs when steady westward blowing trade winds weaken and reverse direction, moving the mass of warm water near Australia eastward to the coast of South America. The displacement of the warm water mass alters the atmospheric jet stream and weather patterns around the world. The TOPEX/Poseidon satellite uses an altimeter to bounce radar signals off the ocean's surface to make precise measurements of the distance between the satellite and sea surface. Researchers then map the barely perceptible hills and valleys of the sea surface by combining these data with measurements pinpointing the satellite's exact location in space.

  17. Cyclic and isothermal oxidation behavior at 1100 and 1200 C of Ni-20Cr, Ni-20Cr-3Mn, Ni-20Cr-3Si, and Ni-40Cr alloys

    NASA Technical Reports Server (NTRS)

    Lowell, C. E.

    1973-01-01

    Alloys of Ni-20Cr, Ni-20Cr-3Mn, Ni-20Cr-3Si, and Ni-40Cr were cyclically oxidized at 1100 and 1200 C for up to 100 hours. Oxidation behavior was judged by sample thickness and weight change, metallography, diffraction, and microprobe analysis. The least attacked were Ni-40Cr and Ni-20Cr-3Si. The alloy Ni-20Cr-3Mn was much less attacked than Ni-20Cr, but more than the other alloys. The formation of Cr2O3 accounted for the increased resistance of Ni-Cr and Ni-20Cr-3Si, and the formation of MnCr2O4 accounts for the improvement in Ni-20Cr-3mn over Ni-20Cr.

  18. Interdiffusion in the Ni/TD-NiCr and Cr/TD-NiCr systems

    NASA Technical Reports Server (NTRS)

    Pawar, A. V.; Tenney, D. R.

    1974-01-01

    The diffusion of Ni and Cr into TD-NiCr has been studied over the 900 to 1100 C temperature range. The diffusion couples were prepared by electroplating Cr and Ni on polished TD-NiCr wafers. Concentration profiles produced as a result of isothermal diffusion at 905, 1000, and 1100 C were determined by electron microprobe analysis. The Boltzmann-Matano analysis was used to determine concentration-dependent diffusion coefficients which were found to compare favorably with previously reported values. These data suggest that 2 vol % ThO2 distribution has no appreciable effect on the rates of diffusion in TD-NiCr with a large grain size. This supports the view that an inert dispersoid in an alloy matrix will not in itself lead to enhanced diffusion unless a short-circuit diffusion structure is stabilized.

  19. The Effect of Metal Composition on Fe-Ni Partition Behavior between Olivine and FeNi-Metal, FeNi-Carbide, FeNi-Sulfide at Elevated Pressure

    NASA Technical Reports Server (NTRS)

    Holzheid, Astrid; Grove, Timothy L.

    2005-01-01

    Metal-olivine Fe-Ni exchange distribution coefficients were determined at 1500 C over the pressure range of 1 to 9 GPa for solid and liquid alloy compositions. The metal alloy composition was varied with respect to the Fe/Ni ratio and the amount of dissolved carbon and sulfur. The Fe/Ni ratio of the metal phase exercises an important control on the abundance of Ni in the olivine. The Ni abundance in the olivine decreases as the Fe/Ni ratio of the coexisting metal increases. The presence of carbon (up to approx. 3.5 wt.%) and sulfur (up to approx. 7.5 wt.%) in solution in the liquid Fe-Ni-metal phase has a minor effect on the partitioning of Fe and Ni between metal and olivine phases. No pressure dependence of the Fe-Ni-metal-olivine exchange behavior in carbon- and sulfur-free and carbon- and sulfur-containing systems was found within the investigated pressure range. To match the Ni abundance in terrestrial mantle olivine, assuming an equilibrium metal-olivine distribution, a sub-chondritic Fe/Ni-metal ratio that is a factor of 17 to 27 lower than the Fe/Ni ratios in estimated Earth core compositions would be required, implying higher Fe concentrations in the core forming metal phase. A simple metal-olivine equilibrium distribution does not seem to be feasible to explain the Ni abundances in the Earth's mantle. An equilibrium between metal and olivine does not exercise a control on the problem of Ni overabundance in the Earth's mantle. The experimental results do not contradict the presence of a magma ocean at the time of terrestrial core formation, if olivine was present in only minor amounts at the time of metal segregation.

  20. Phase-specific Geochemistry of Ni: a Tracer of Geosphere-Biosphere Co-evolution?

    NASA Astrophysics Data System (ADS)

    Ciscato, E. R.; Vance, D.; Bontognali, T. R. R.; Poulton, S.

    2016-12-01

    Metalloproteome analyses and culturing studies have suggested that trace metals, such as Cu, Fe, Mo, Ni, and Zn, were selectively utilized by different organisms and specific metabolisms throughout the evolution of the biosphere. Methanogens have a particular requirement for Ni and culturing studies have shown that they fractionate Ni isotopes upon uptake. It is not clear, however, whether a resulting Ni isotopic signal can be preserved in the geological record. We have developed a new approach that enables us to analyze phase-specific authigenic trace metal enrichments, and their respective isotopic signatures, in (predominantly organic-rich) sediments from the geological record. An acid digestion step followed by high-pressure ashing allows us to separate an `organic matter + Pyrite' phase from an `HF-extractable' phase. We have applied this approach to investigate the distribution of Ni isotopes in a variety of modern sediments, including organic-rich sediments from upwelling margins and a hypersaline lagoonal setting where methanogenesis is likely to be an active process. Preliminary results on geological record samples show a δ60Ni for the `HF-extractable' phases that agrees with the average continental crust, whereas the `organic matter + Pyrite' phases are heavier and shifted in the direction of modern seawater. By combining this data with our δ60Ni dataset from modern sediments, we investigate the dynamics of Ni cycling in environments with different O2 and H2S availabilities both in the modern and throughout the past 3.2 billion years. Our phase-specific δ60Ni record is of instrumental importance in determining whether a biologically induced fractionation imparted by methanogens is indeed observable, and if it can be used as a biosignature for tracing the predominance of methanogenic pathways throughout the co-evolution of the geosphere and biosphere.

  1. Root-canal shaping with manual and rotary Ni-Ti files performed by students.

    PubMed

    Sonntag, D; Delschen, S; Stachniss, V

    2003-11-01

    To investigate root-canal shaping with manual and rotary Ni-Ti files performed by students. Thirty undergraduate dental students prepared 150 simulated curved root canals in resin blocks with manual Ni-Ti files with a stepback technique and 450 simulated curved canals with rotary Ni-Ti files with a crowndown technique. Incidence of fracture, preparation length, canal shape and preparation time were investigated. Questionnaires were then issued to the students for them to note their experience of the two preparation methods. Zips and elbows occurred significantly (P < 0.001) less frequently with rotary than with manual preparation. The correct preparation length was achieved significantly (P < 0.05) more often with rotary files than with manual files. Instrument fractures were recorded in only 1.3% of cases with both rotary and manual preparation. The mean time required for manual preparation was significantly (P < 0.001) longer than that required for rotary preparation. Prior experience with a hand preparation technique was not reflected in an improved quality of the subsequent rotary preparation. Approximately 83% of the students claimed to have a greater sense of security in rotary than in manual preparation. Overall 50% felt that manual and engine-driven preparation should be given equal status in undergraduate dental education. Inexperienced operators achieved better canal preparations with rotary instruments than with manual files. No difference in fracture rate was recorded between the two systems.

  2. Recent enhancement of central Pacific El Niño variability relative to last eight centuries

    PubMed Central

    Liu, Yu; Cobb, Kim M.; Song, Huiming; Li, Qiang; Li, Ching-Yao; Nakatsuka, Takeshi; An, Zhisheng; Zhou, Weijian; Cai, Qiufang; Li, Jinbao; Leavitt, Steven W.; Sun, Changfeng; Mei, Ruochen; Shen, Chuan-Chou; Chan, Ming-Hsun; Sun, Junyan; Yan, Libin; Lei, Ying; Ma, Yongyong; Li, Xuxiang; Chen, Deliang; Linderholm, Hans W.

    2017-01-01

    The far-reaching impacts of central Pacific El Niño events on global climate differ appreciably from those associated with eastern Pacific El Niño events. Central Pacific El Niño events may become more frequent in coming decades as atmospheric greenhouse gas concentrations rise, but the instrumental record of central Pacific sea-surface temperatures is too short to detect potential trends. Here we present an annually resolved reconstruction of NIÑO4 sea-surface temperature, located in the central equatorial Pacific, based on oxygen isotopic time series from Taiwan tree cellulose that span from 1190 AD to 2007 AD. Our reconstruction indicates that relatively warm Niño4 sea-surface temperature values over the late twentieth century are accompanied by higher levels of interannual variability than observed in other intervals of the 818-year-long reconstruction. Our results imply that anthropogenic greenhouse forcing may be driving an increase in central Pacific El Niño-Southern Oscillation variability and/or its hydrological impacts, consistent with recent modelling studies. PMID:28555638

  3. On the nature of Ni···Ni interaction in a model dimeric Ni complex.

    PubMed

    Kamiński, Radosław; Herbaczyńska, Beata; Srebro, Monika; Pietrzykowski, Antoni; Michalak, Artur; Jerzykiewicz, Lucjan B; Woźniak, Krzysztof

    2011-06-07

    A new dinuclear complex (NiC(5)H(4)SiMe(2)CHCH(2))(2) (2) was prepared by reacting nickelocene derivative [(C(5)H(4)SiMe(2)CH=CH(2))(2)Ni] (1) with methyllithium (MeLi). Good quality crystals were subjected to a high-resolution X-ray measurement. Subsequent multipole refinement yielded accurate description of electron density distribution. Detailed inspection of experimental electron density in Ni···Ni contact revealed that the nickel atoms are bonded and significant deformation of the metal valence shell is related to different populations of the d-orbitals. The existence of the Ni···Ni bond path explains the lack of unpaired electrons in the complex due to a possible exchange channel.

  4. Nickel (Ni) allergic patients with complications to Ni containing joint replacement show preferential IL-17 type reactivity to Ni.

    PubMed

    Summer, Burkhard; Paul, Carina; Mazoochian, Farhad; Rau, Christoph; Thomsen, Marc; Banke, Ingo; Gollwitzer, Hans; Dietrich, Karin-Almut; Mayer-Wagner, Susanne; Ruzicka, Thomas; Thomas, Peter

    2010-07-01

    Some nickel (Ni) allergic patients develop complications following Ni-containing arthroplasty. In the peri-implant tissue of such patients, we had observed lymphocyte dominated inflammation together with IFN-gamma and IL-17 expression. To determine whether Ni stimulation of peripheral blood mononuclear cells (PBMCs) of such patients would lead to a different cytokine pattern as compared to Ni-allergic patients with symptom-free arthroplasty. Based on history and patch testing in 15 Ni-allergic patients (five without implant, five with symptom-free arthroplasty, five with complicated arthroplasty) and five non-allergic individuals, lymphocyte transformation test (LTT) was performed using PBMC. In parallel in vitro cytokine response to Ni was assessed by real-time reverse transcriptase-polymerase chain reaction (RT-PCR). All 15 Ni-allergic individuals showed enhanced LTT reactivity to Ni (mean SI = 8.42 +/- 1.8) compared to the non-allergic control group. Predominant IFN-gamma expression to Ni was found both in the five allergic patients without arthroplasty and also in the five allergic, symptom-free arthroplasty patients. In contrast, in the five Ni-allergic patients with arthroplasty-linked complications a predominant, significant IL-17 expression to Ni was seen but not in patients with symptom-free arthroplasty. The predominant IL-17 type response to Ni may characterize a subgroup of Ni-allergic patients prone to develop lymphocytic peri-implant hyper-reactivity.

  5. Apically extruded debris in filling removal of curved canals using 3 NiTi systems and hand files.

    PubMed

    Delai, Débora; Boijink, Daiana; Hoppe, Carolina Bender; Grecca, Abiana Soares; Kopper, Patrícia Maria Poli

    2018-01-01

    The aim of this study was to assess the amount of apically extruded debris during filling removal with WaveOne Gold (WOG), ProTaper Universal Retreatment (PTR), D-RaCe Retreatment (DRR) or hand files (HF), to compare the working time during filling removal, and to describe failures of NiTi instruments. Forty mesiobuccal roots of maxillary first molars were prepared with WOG Primary, obturated and divided into 4 groups (n=10), according to the instruments used: WOG, PTR, DRR or HF. Distilled water was used as irrigant and the extruded debris were collected in Eppendorf tubes and dried. The amount of extruded debris was determined by subtracting the final from the initial weight. The time of filling removal for each canal was recorded and the instruments used were analyzed pre and post-operatively by SEM. Kruskal-Wallis and Dunn's test analyzed extruded debris data and ANOVA, followed by Tukey's test, compared the working time data (a=0.05). Instrument deformation and fracture were described. WOG produced significantly less debris compared with HF and DRR (p<0.05), and similar to PTR (p>0.05). HF, PTR and DRR showed no significant difference (p>0.05). Working time in HF group was significantly higher than others (p<0.05). SEM analyses showed, from the 18 instruments evaluated, 3 fractures and 10 deformations. All instruments tested caused debris extrusion. WOG was associated with less extrusion than DRR and HF. Filling removal with HF was slower than with the other instruments. All NiTi systems presented fracture and deformation.

  6. The Ni-rich part of the Al–Ge–Ni phase diagram

    PubMed Central

    Jandl, Isabella; Reichmann, Thomas L.; Richter, Klaus W.

    2013-01-01

    The Ni-rich part of the ternary system Al–Ge–Ni (xNi > 50 at.%) was investigated by means of optical microscopy, powder X-ray diffraction (XRD), differential thermal analysis (DTA) and scanning electron microscopy (SEM). The two isothermal sections at 550 °C and 700 °C were determined. Within these two sections a new ternary phase, designated as τ4, AlyGe9−yNi13±x (hP66, Ga3Ge6Ni13-type) was detected and investigated by single crystal X-ray diffraction. Another ternary low temperature phase, τ5, was found only in the isothermal section at 550 °C around the composition AlGeNi4. This compound was found to crystallise in the Co2Si type structure (oP12, Pnma). The structure was identified by Rietveld refinement of powder data. The NiAs type (B8) phase based on binary Ge3Ni5 revealed an extended solid solubility of Al and the two isotypic compounds AlNi3 and GeNi3 form a complete solid solution. Based on DTA results, six vertical sections at 55, 60, 70, 75 and 80 at.% Ni and at a constant Al:Ni ratio of 1:3 were constructed. Furthermore, the liquidus surface projection and the reaction scheme (Scheil diagram) were completed by combining our results with previous results from the Ni-poor part of the phase diagram. Six invariant ternary reactions were identified in the Ni-rich part of the system. PMID:27087754

  7. Kinetics of Ni2Si growth from pure Ni and Ni(V) films on (111) and (100) Si

    NASA Astrophysics Data System (ADS)

    Harith, M. A.; Zhang, J. P.; Campisano, S. U.; Klaar, H.-J.

    1987-01-01

    The kinetics of Ni2Si growth from pure Ni and from Ni0.93V0.07 films on (111) and (100) silicon has been studied by the combination of He+ backscattering, x-ray diffraction, Auger electron spectroscopy (AES) and transmission electron microscopy (TEM) techniques. The activation energies are 1.5 and 1.0 eV for pure Ni and Ni(V) films, respectively while the pre-exponential factors in Ni(V) are 4 5 orders of magnitude smaller than in the pure Ni case. The variations in the measured rates are related to the different grain size of the growing suicide layers. The vanadium is rejected from the silicide layer and piles up at the metalsilicide interface.

  8. Tuning Ni-catalyzed CO 2 hydrogenation selectivity via Ni-ceria support interactions and Ni-Fe bimetallic formation

    DOE PAGES

    Winter, Lea R.; Gomez, Elaine; Yan, Binhang; ...

    2017-10-16

    CO 2 hydrogenation over Fe-modified Ni/CeO 2 catalysts was investigated in a batch reactor using time-resolved in situ FTIR spectroscopy. Low loading of Ni/CeO 2 was associated with high selectivity to CO over CH 4, while higher Ni loading improved CO 2 hydrogenation activity with a reduced CO selectivity. X-ray absorption near-edge structure (XANES) analysis revealed Ni to be metallic for all catalysts including the CO-selective low loading 0.5% Ni catalyst, suggesting that the selectivity trend is due to structural rather than oxidation state effects. The loading amount of 1.5% Ni was selected for co-impregnation with Fe, based on themore » significant shift in product selectivity towards CH 4 for that loading amount, in order to shift the selectivity towards CO while maintaining high activity. Temperature programmed reduction (TPR) results indicated bimetallic interactions between Ni and Fe, and XANES analysis showed that about 70% of Fe in the bimetallic catalysts was oxidized. The Ni-Fe catalysts demonstrated improved selectivity towards CO without significantly compromising activity, coupling the high activity of Ni catalysts and the high CO selectivity of Fe. The general trends in Ni loading and bimetallic modification should guide efforts to develop non-precious metal catalysts for the selective production of CO by CO 2 hydrogenation.« less

  9. Walker Circulation, El Niño and La Niña

    NASA Astrophysics Data System (ADS)

    Halpern, D.

    2014-12-01

    Ocean surface wind vector is likely the critical variable to predict onset, maintenance and dissipation of El Niño and La Niña. Analyses of SeaWinds and ASCAT 10-m height (called "surface") vector winds in the Atlantic, Indian and Pacific Oceans from 1°S-1°N during March 2000 - June 2011 revealed the longitudinal distribution of the surface zonal wind component associated with the Walker Circulation. In the Pacific Ocean east of 140°E and west of 85°W, the mean wind direction was westward towards the maritime continent with maximum mean zonal wind speed (- 6.5 m s-1) at 150°W; east of 85°W the mean direction was toward the convection zone over South America. Four El Niños and five La Niñas occurred from March 2000 - June 2011. In the Pacific from 150°E to 160°W, the average El Niño (La Niña) westward wind speed was 2 m s-1 (1 m s-1) smaller (larger) than normal. In the west Pacific, the variation in westward wind speeds in El Niño and La Niña conditions relative to normal conditions would be expected to substantially uplift the thermocline during El Niño compared to La Niña, which is consistent with conventional wisdom. In the east Pacific from 130°W - 100°W, average El Niño westward wind speeds were less than normal and La Niña conditions by 0.5 m s-1 and 1 m s-1, respectively. The "central" Pacific nature of the El Niños may have influenced the smaller difference between El Niño and La Niña westward wind speeds in the east Pacific compared to the west Pacific. Analyses of longitudinal distributions of thermocline depths will be discussed. Surface zonal wind speeds in the Atlantic and Indian Oceans showed no evidence of El Niño and La Niña; surface meridional winds showed an apparent response in the Indian and Pacific Oceans but not in the Atlantic Ocean. At 700-m height, the MISR zonal wind component in the Atlantic, Indian and Pacific Oceans had similar features as those at the surface, except in the east Pacific where the westward

  10. High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suite Gas Processing System (GPS) Carbon Dioxide Scrubber

    NASA Technical Reports Server (NTRS)

    Hoffman, Christopher; Munoz, Bruno; Gundersen, Cynthia; Thomas, Walter, III; Stephenson, Timothy

    2008-01-01

    In support of the GPS for the SAM instrument suite built by NASA/GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr alloy wire, 0.0142 cm diameter, for use as a heater element for the carbon dioxide scrubber. The element would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The element also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni- 20Cr in low pressure CO2, coupled with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the element reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

  11. High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suit Gas Processing System (GPS) Carbon Dioxide Scrubber

    NASA Technical Reports Server (NTRS)

    Gundersen, Cynthia; Hoffman, Christopher; Munoz, Bruno; Steohenson, Timothy; Thomas, Walter

    2008-01-01

    In support of the GPS for the SAM instrument suite built by GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr wire, 0.0056 inches in diameter, for use as a heater element for the carbon dioxide scrubber. The wire would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The wire also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni-20Cr in low pressure CO2, together with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the wire reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

  12. Ni-NiO core-shell inverse opal electrodes for supercapacitors.

    PubMed

    Kim, Jae-Hun; Kang, Soon Hyung; Zhu, Kai; Kim, Jin Young; Neale, Nathan R; Frank, Arthur J

    2011-05-14

    A general template-assisted electrochemical approach was used to synthesize three-dimensional ordered Ni core-NiO shell inverse opals (IOs) as electrodes for supercapacitors. The Ni-NiO IO electrodes displayed pseudo-capacitor behavior, good rate capability and cycling performance. © The Royal Society of Chemistry 2011

  13. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments.

    PubMed

    Pedullà, E; Lo Savio, F; Boninelli, S; Plotino, G; Grande, N M; Rapisarda, E; La Rosa, G

    2015-11-01

    To evaluate the effect of different torsional preloads on cyclic fatigue resistance of endodontic rotary instruments constructed from conventional nickel-titanium (NiTi), M-Wire or CM-Wire. Eighty new size 25, 0.06 taper Mtwo instruments (Sweden & Martina), size 25, 0.06 taper HyFlex CM (Coltene/Whaledent, Inc) and X2 ProTaper Next (Dentsply Maillefer) were used. The Torque and distortion angles at failure of new instruments (n = 10) were measured, and 0% (n = 10), 25%, 50% and 75% (n = 20) of the mean ultimate torsional strength as preloading condition were applied according to ISO 3630-1 for each brand. The twenty files tested for every extent of preload were subjected to 20 or 40 torsional cycles (n = 10). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal with 60° angle of curvature and 5 mm of radius of curvature. Data were analysed using two-way analysis of variance. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). Data were analysed by two-way analyses of variance. Preload repetitions did not influence the cyclic fatigue of the three brands; however, the 25%, 50% and 75% torsional preloading significantly reduced the fatigue resistance of all instruments tested (P < 0.01, P < 0.001 and P < 0.0001, respectively) except for the HyFlex CM preloaded with 25% of the maximum torsional strength (P > 0.05). Torsional preloads reduced the cyclic fatigue resistance of conventional and treated (M-wire and CM-wire) NiTi rotary instruments except for size 25, 0.06 taper HyFlex CM instruments with a 25% of torsional preloading. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. An Ultrastable and High-Performance Flexible Fiber-Shaped Ni-Zn Battery based on a Ni-NiO Heterostructured Nanosheet Cathode.

    PubMed

    Zeng, Yinxiang; Meng, Yue; Lai, Zhengzhe; Zhang, Xiyue; Yu, Minghao; Fang, Pingping; Wu, Mingmei; Tong, Yexiang; Lu, Xihong

    2017-11-01

    Currently, the main bottleneck for the widespread application of Ni-Zn batteries is their poor cycling stability as a result of the irreversibility of the Ni-based cathode and dendrite formation of the Zn anode during the charging-discharging processes. Herein, a highly rechargeable, flexible, fiber-shaped Ni-Zn battery with impressive electrochemical performance is rationally demonstrated by employing Ni-NiO heterostructured nanosheets as the cathode. Benefiting from the improved conductivity and enhanced electroactivity of the Ni-NiO heterojunction nanosheet cathode, the as-fabricated fiber-shaped Ni-NiO//Zn battery displays high capacity and admirable rate capability. More importantly, this Ni-NiO//Zn battery shows unprecedented cyclic durability both in aqueous (96.6% capacity retention after 10 000 cycles) and polymer (almost no capacity attenuation after 10 000 cycles at 22.2 A g -1 ) electrolytes. Moreover, a peak energy density of 6.6 µWh cm -2 , together with a remarkable power density of 20.2 mW cm -2 , is achieved by the flexible quasi-solid-state fiber-shaped Ni-NiO//Zn battery, outperforming most reported fiber-shaped energy-storage devices. Such a novel concept of a fiber-shaped Ni-Zn battery with impressive stability will greatly enrich the flexible energy-storage technologies for future portable/wearable electronic applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Apically extruded debris with three contemporary Ni-Ti instrumentation systems: an ex vivo comparative study.

    PubMed

    Logani, Ajay; Shah, Naseem

    2008-01-01

    To comparatively evaluate the amount of apically extruded debris when ProTaper hand, ProTaper rotary and ProFile systems were used for the instrumentation of root canals. Thirty minimally curved, mature, human mandibular premolars with single canals were randomly divided into three groups of ten teeth each. Each group was instrumented using one of the three instrumentation systems: ProTaper hand, ProTaper rotary and ProFile. Five milliliters of sterile water were used as an irrigant. Debris extruded was collected in preweighed polyethylene vials and the extruded irrigant was evaporated. The weight of the dry extruded debris was established by comparing the pre- and postinstrumentation weight of polyethylene vials for each group. The Kruskal-Wallis nonparametric test and Mann-Whitney U test were applied to determine if significant differences existed among the groups ( P< 0.05). All instruments tested produced a measurable amount of debris. No statistically significant difference was observed between ProTaper hand and ProFile system ( P > 0.05). Although ProTaper rotary extruded a relatively higher amount of debris, no statistically significant difference was observed between this type and the ProTaper hand instruments ( P > 0.05). The ProTaper rotary extruded significantly more amount of debris compared to the ProFile system ( P< 0.05). Within the limitations of this study, it can be concluded that all instruments tested produced apical extrusion of debris. The ProTaper rotary extruded a significantly higher amount of debris than the ProFile.

  16. Comparison of the mechanical properties of rotary instruments made of conventional nickel-titanium wire, M-wire, or nickel-titanium alloy in R-phase.

    PubMed

    Lopes, Hélio P; Gambarra-Soares, Thaiane; Elias, Carlos N; Siqueira, José F; Inojosa, Inês F J; Lopes, Weber S P; Vieira, Victor T L

    2013-04-01

    This study compared the mechanical properties of endodontic instruments made of conventional nickel-titanium (NiTi) wire (K(3) and Revo-S SU), M-Wire (ProFile Vortex), or NiTi alloy in R-phase (K(3)XF). The test instruments were subjected to mechanical tests to evaluate resistance to bending (flexibility), cyclic fatigue, and torsional load in clockwise rotation. Data were statistically evaluated by the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons. In the bending resistance test, flexibility decreased in the following order: K(3)XF > Revo-S SU > ProFile Vortex > K(3). The ranking in the fatigue resistance test was the following: K(3)XF > K(3) > ProFile Vortex > Revo-S SU. In the torsional assay, the angular deflection at failure decreased in the following order: K(3)XF > Revo-S SU > K(3) > ProFile Vortex. For the maximum torque values, the ranking was K(3) > K(3)XF > ProFile Vortex > Revo-S SU. The results showed that the K(3)XF instrument, which is made of NiTi alloy in R-phase, had the overall best performance in terms of flexibility, angular deflection at failure, and cyclic fatigue resistance. In addition to the alloy from which the instrument is manufactured, the design and dimensions are important determinants of the mechanical performance of endodontic instruments. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Projected increase in El Niño-driven tropical cyclone frequency in the Pacific

    NASA Astrophysics Data System (ADS)

    Chand, Savin S.; Tory, Kevin J.; Ye, Hua; Walsh, Kevin J. E.

    2017-02-01

    The El Niño/Southern Oscillation (ENSO) drives substantial variability in tropical cyclone (TC) activity around the world. However, it remains uncertain how the projected future changes in ENSO under greenhouse warming will affect TC activity, apart from an expectation that the overall frequency of TCs is likely to decrease for most ocean basins. Here we show robust changes in ENSO-driven variability in TC occurrence by the late twenty-first century. In particular, we show that TCs become more frequent (~20-40%) during future-climate El Niño events compared with present-climate El Niño events--and less frequent during future-climate La Niña events--around a group of small island nations (for example, Fiji, Vanuatu, Marshall Islands and Hawaii) in the Pacific. We examine TCs across 20 models from the Coupled Model Intercomparison Project phase 5 database, forced under historical and greenhouse warming conditions. The 12 most realistic models identified show a strong consensus on El Niño-driven changes in future-climate large-scale environmental conditions that modulate development of TCs over the off-equatorial western Pacific and the central North Pacific regions. These results have important implications for climate change and adaptation pathways for the vulnerable Pacific island nations.

  18. Porous NiTi shape memory alloys produced by SHS: microstructure and biocompatibility in comparison with Ti2Ni and TiNi3.

    PubMed

    Bassani, Paola; Panseri, Silvia; Ruffini, Andrea; Montesi, Monica; Ghetti, Martina; Zanotti, Claudio; Tampieri, Anna; Tuissi, Ausonio

    2014-10-01

    Shape memory alloys based on NiTi have found their main applications in manufacturing of new biomedical devices mainly in surgery tools, stents and orthopedics. Porous NiTi can exhibit an engineering elastic modulus comparable to that of cortical bone (12-17 GPa). This condition, combined with proper pore size, allows good osteointegration. Open cells porous NiTi was produced by self propagating high temperature synthesis (SHS), starting from Ni and Ti mixed powders. The main NiTi phase is formed during SHS together with other Ni-Ti compounds. The biocompatibility of such material was investigated by single culture experiment and ionic release on small specimen. In particular, NiTi and porous NiTi were evaluated together with elemental Ti and Ni reference metals and the two intermetallic TiNi3, Ti2Ni phases. This approach permitted to clearly identify the influence of secondary phases in porous NiTi materials and relation with Ni-ion release. The results indicated, apart the well-known high toxicity of Ni, also toxicity of TiNi3, whilst phases with higher Ti content showed high biocompatibility. A slightly reduced biocompatibility of porous NiTi was ascribed to combined effect of TiNi3 presence and topography that requires higher effort for the cells to adapt to the surface.

  19. NiP black: vers l'utilisation d'un traitement plus noir que noir contre la lumière parasite

    NASA Astrophysics Data System (ADS)

    Mazuray, L.; Petilon, JF.

    2017-11-01

    Le NiP black est un alliage de Nickel-Phosphore poreux présentant un coefficient d'absorption exceptionnel de 0.998, permettant un gain en diffusion d'un facteur 10 à 20 par rapport à la meilleure des peintures noires utilisée sur les baffles et montures des instruments d'optique. L'industrialisation de ce procédé fait l'objet d'une collaboration entre le CNES, SODERN et MMS afin de répondre au mieux aux exigences des différents instruments spatiaux. Le faible niveau de diffusion des baffles et des montures des instruments optiques est un élément clé d'un faible niveau de lumière parasite et par voie de conséquence, des performances en détection, imagerie et d'analyse. Les essais réalisés en 98 et 99 sur des visières de senseurs solaires haute précision implantés sur les plate-formes telecom MMS ont confirmé les excellentes performances du senseur obtenues grâce à ce traitement. NiP Black s'incrit dans une démarche générale MMS d'amélioration des performances en lumière parasite des instruments optiques. Il est proposé de présenter le NiP Black et les performances réalisées sur des visières de senseurs implantés sur les plate-formes MMS, ainsi que son potentiel à venir.

  20. Synthesis and synchrotron X-ray characterization of two 2D Hoffman related compounds [Ni(p-Xylylenediamine)nNi(CN)4] and [Ni(p-tetrafluoroxylylenediamine)nNi(CN)4

    NASA Astrophysics Data System (ADS)

    Wong-Ng, W.; Culp, J. T.; Siderius, D. W.; Chen, Y. S.

    2018-07-01

    Synchrotron X-ray single crystal structure determination of two 2D Hofmann-related compounds, [Ni(p-Xylyenediamine)n-tetracyanonickelate] (abbreviated as Ni-pXdam) and [Ni(tetrafluoro-p-Xylyenediamine)n-tetracyanonickelate] (abbreviated as Ni-pXdamF4), have been conducted. Both the pXdam and pXdamF4 ligands contain two short chains of -CH2NH2 at the para-positions of a phenyl ring. These flexible chains link the 6-fold coordinated Ni2 sites throughout the network. In Ni-pXdam, the closed-2D network of [Ni-(CN-Ni1/4-)4]∞ is broken into 1D chains, leaving the C≡N groups at the trans-positions of the Ni(CN)4 moiety unbridged. The resulting 1D chains [(trans-)-NC-Ni(CN)2-CN-Ni-]∞ runs along the [010] direction of the unit cell. The pXdam ligands bridge in pair between the Ni atoms of the adjacent chains. The catenation structure of [Ni{(pXdam)}]∞ could be referred to as double -1D. In Ni-pXdamF4, the -CH2NH2 ligands connect the neighboring chains via the 6-fold Ni2 site. Surrounding the 4-fold Ni1 site, the two trans terminal C≡N groups were replaced by the Lewis base NH3 during the synthesis process, therefore preventing the propagation of the 2D net to form a 3D network. Computed pore volume of both compounds indicated that there is not sufficient space in the structure to accommodate gas molecules. In both compounds, hydrogen bonds were found, and solvent of crystallization was absent due to the limited free space in the structure.

  1. On the similarity of the bonding in NiS and NiO

    NASA Technical Reports Server (NTRS)

    Bauschlicher, C. W., Jr.

    1985-01-01

    The bonding in NiS is found to be quite similar to that in NiO, having an ionic contribution arising from the donation of the Ni 4s electron to the S atom and a covalent component arising from bonds between the Ni 3d and the S 3p. The one-electron d bonds are found to be of equal strength for NiO and NiS, but the two-electron d bonds are weaker for NiS.

  2. LST and instrument considerations. [modular design

    NASA Technical Reports Server (NTRS)

    Levin, G. M.

    1974-01-01

    In order that the LST meet its scientific objectives and also be a National Astronomical Space Facility during the 1980's and 1990's, broad requirements have been levied by the scientific community. These scientific requirements can be directly translated into design requirements and specifications for the scientific instruments. The instrument ensemble design must be consistent with a 15-year operational lifetime. Downtime for major repair/refurbishment or instrument updating must be minimized. The overall efficiency and performance of the instruments should be maximized. Modularization of instruments and instrument subsystems, some degree of on-orbit servicing (both repair and replacement), on-axis location, minimizing the number of reflections within instruments, minimizing polarization effects, and simultaneous operation of the F/24 camera with other instruments, are just a few of the design guidelines and specifications which can and will be met in order that these broader scientific requirements be satisfied.-

  3. Measurement of 59Ni and 63Ni by accelerator mass spectrometry at CIAE

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoming; He, Ming; Ruan, Xiangdong; Xu, Yongning; Shen, Hongtao; Du, Liang; Xiao, Caijin; Dong, Kejun; Jiang, Shan; Yang, Xuran; Lan, Xiaoxi; Wu, Shaoyong; Zhao, Qingzhang; Cai, Li; Pang, Fangfang

    2015-10-01

    The long lived isotopes 59Ni and 63Ni can be used in many areas such as radioactive waste management, neutron dosimetry, cosmic radiation study, and so on. Based on the large accelerator and a big Q3D magnetic spectrometer, the measurement method for 59Ni and 63Ni is under development at the AMS facility at China Institute of Atomic Energy (CIAE). By using the ΔE-Q3D technique with the Q3D magnetic spectrometer, the isobaric interferences were greatly reduced in the measurements of 59Ni and 63Ni. A four anode gas ionization chamber was then used to further identify isobars. With these techniques, the abundance sensitivities of 59Ni and 63Ni measurements are determined as 59Ni/Ni = 1 × 10-13 and 63Ni/Ni = 2 × 10-12, respectively.

  4. Morphology controlled synthesis of 2-D Ni-Ni3S2 and Ni3S2 nanostructures on Ni foam towards oxygen evolution reaction

    NASA Astrophysics Data System (ADS)

    Chaudhari, Nitin Kaduba; Oh, Aram; Sa, Young Jin; Jin, Haneul; Baik, Hionsuck; Kim, Sang Gu; Lee, Suk Joong; Joo, Sang Hoon; Lee, Kwangyeol

    2017-03-01

    Catalysts for oxygen evolution reactions (OER) are at the heart of key renewable energy technologies, and development of non-precious metal catalysts with high activity and stability remain a great challenge in this field. Among various material candidates, metal sulfides are receiving increasing attention. While morphology-dependent catalytic performances are well established in noble metal-based catalysts, relatively little is known for the morphology‒catalytic performance relationship in metal sulfide catalysts. In this study, uniform spider web-like Ni nanosheets-Ni3S2 and honeycomb-like Ni3S2 structures are deposited on nickel foam (Ni3S2/NF) by a facile one-step hydrothermal synthetic route. When used as an oxygen evolution electrode, the spider web-like Ni-Ni3S2/NF with the large exposed surface area shown excellent catalytic activity and stability with an overpotential of 310 mV to achieve at 10 mA/cm2 and a Tafel slope of 63 mV/dec in alkaline media, which is superior to the honeycomb-like structure without Ni nanosheet. The low Tafel slope of the spider web-like Ni-Ni3S2/NF represents one of the best OER kinetics among nickel sulfide-based OER catalysts. The results point to the fact that performance of the metal sulfide electrocatalysts might be fine-tuned and optimized with morphological controls.

  5. 63Ni (n ,γ ) cross sections measured with DANCE

    NASA Astrophysics Data System (ADS)

    Weigand, M.; Bredeweg, T. A.; Couture, A.; Göbel, K.; Heftrich, T.; Jandel, M.; Käppeler, F.; Lederer, C.; Kivel, N.; Korschinek, G.; Krtička, M.; O'Donnell, J. M.; Ostermöller, J.; Plag, R.; Reifarth, R.; Schumann, D.; Ullmann, J. L.; Wallner, A.

    2015-10-01

    The neutron capture cross section of the s -process branch nucleus 63Ni affects the abundances of other nuclei in its region, especially 63Cu and 64Zn. In order to determine the energy-dependent neutron capture cross section in the astrophysical energy region, an experiment at the Los Alamos National Laboratory has been performed using the calorimetric 4 π BaF2 array DANCE. The (n ,γ ) cross section of 63Ni has been determined relative to the well-known 197Au standard with uncertainties below 15%. Various 63Ni resonances have been identified based on the Q value. Furthermore, the s -process sensitivity of the new values was analyzed with the new network calculation tool NETZ.

  6. Predictability of the Ningaloo Niño/Niña

    PubMed Central

    Doi, Takeshi; Behera, Swadhin K.; Yamagata, Toshio

    2013-01-01

    The seasonal prediction of the coastal oceanic warm event off West Australia, recently named the Ningaloo Niño, is explored by use of a state-of-the-art ocean-atmosphere coupled general circulation model. The Ningaloo Niño/Niña, which generally matures in austral summer, is found to be predictable two seasons ahead. In particular, the unprecedented extreme warm event in February 2011 was successfully predicted 9 months in advance. The successful prediction of the Ningaloo Niño is mainly due to the high prediction skill of La Niña in the Pacific. However, the model deficiency to underestimate its early evolution and peak amplitude needs to be improved. Since the Ningaloo Niño/Niña has potential impacts on regional societies and industries through extreme events, the present success of its prediction may encourage development of its early warning system. PMID:24100593

  7. Comparison of two techniques for assessing the shaping efficacy of repeatedly used nickel-titanium rotary instruments.

    PubMed

    Ounsi, Hani F; Franciosi, Giovanni; Paragliola, Raffaele; Al-Hezaimi, Khalid; Salameh, Ziad; Tay, Franklin R; Ferrari, Marco; Grandini, Simone

    2011-06-01

    The shaping capacity of nickel-titanium (NiTi) rotary instruments is often assessed by photographic or micro-computed tomography (micro-CT) measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-CT measurements and to assess if the repeated use of NiTi instruments affected the shape of canal preparation. Ten new sets of ProTaper Universal instruments (Dentsply-Maillefer, Ballaigues, Switzerland) were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented the first to sixth use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm(2)) were calculated using AutoCAD (Autodesk Inc, San Rafael, CA). The volumes of the same prepared canals were measured using micro-CT (mm(3)). Statistical analysis was performed to detect differences between photographic and volumetric measurements and differences between uses. Two-way repeated-measures analysis of variance revealed significant differences between groups (P < .001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL measurements (P < .001) and micro-CT and MD measurements (P=.001). Significant differences were also noted between uses. Within the limitations of the present study, micro-CT scanning is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Charge ordering in Ni 1 + / Ni 2 + nickelates: La 4 Ni 3 O 8 and La 3 Ni 2 O 6

    DOE PAGES

    Botana, Antia S.; Pardo, Victor; Pickett, Warren E.; ...

    2016-08-09

    Ab initio calculations allow us to establish a close connection between the Ruddlesden-Popper layered nickelates and cuprates not only in terms of filling of d levels (close to d 9) but also because they show Ni 1+(S = 1/2)/Ni 2+(S = 0) stripe ordering. We obtained the insulating charge-ordered ground state from a combination of structural distortions and magnetic order. The Ni 2+ ions are in a low-spin configuration (S = 0) yielding an antiferromagnetic arrangement of Ni 1+ S = 1/2 ions like the long-sought spin-1/2 antiferromagnetic insulator analog of the cuprate parent materials. Furthermore, the analogy extends further with the main contribution to the bands near the Fermi energy coming from hybridized Ni d more » $$_x$$ 2- $$_y$$ 2 and O $p$ states.« less

  9. Ferromagnetic resonance investigation in as-prepared NiFe/FeMn/NiFe trilayer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, S. J.; Xu, K.; Yu, L. M.

    2007-06-01

    NiFe/FeMn/NiFe trilayer prepared by dc magnetron sputtering was systematically investigated by ferromagnetic resonance technique (FMR) at room temperature. For NiFe/FeMn/NiFe trilayer, there are two distinct resonance peaks both in in-plane and out-of-plane FMR spectra, which are attributed to the two NiFe layers, respectively. The isotropic in-plane resonance field shift is negative for the bottom NiFe layer, while positive for the top NiFe layer. And, such phenomena result from the negative interfacial perpendicular anisotropy at the bottom NiFe/FeMn interface and positive interfacial perpendicular anisotropy at the top FeMn/NiFe interface. The linewidth of the bottom NiFe layer is larger than that ofmore » the top NiFe layer, which might be related to the greater exchange coupling at the bottom NiFe/FeMn interface.« less

  10. Ni Foam-Ni3 S2 @Ni(OH)2 -Graphene Sandwich Structure Electrode Materials: Facile Synthesis and High Supercapacitor Performance.

    PubMed

    Wang, Xiaobing; Hu, Jiangjiang; Su, Yichang; Hao, Jin; Liu, Fanggang; Han, Shuang; An, Jian; Lian, Jianshe

    2017-03-23

    A novel Ni foam-Ni 3 S 2 @Ni(OH) 2 -graphene sandwich-structured electrode (NF-NN-G) with high areal mass loading (8.33 mg cm -2 ) has been developed by sulfidation and hydrolysis reactions. The conductivity of Ni 3 S 2 and Ni(OH) 2 were both improved. The upper layer of Ni(OH) 2 , covered with a thin graphene film, is formed in situ from the surface of the lower layer of Ni 3 S 2 , whereas the Ni 3 S 2 grown on Ni foam substrate mainly acts as a rough support bridging the Ni(OH) 2 and Ni foam. The graphene stabilized the Ni(OH) 2 and the electrochemical properties were effectively enhanced. The as-synthesized NF-NN-G-5mg electrode shows a high specific capacitance (2258 F g -1 at 1 A g -1 or 18.81 F cm -2 at 8.33 mA cm -2 ) and an outstanding rate property (1010 F g -1 at 20 Ag -1 or 8.413 F cm -2 at 166.6 mA cm -2 ). This result is around double the capacitance achieved in previous research on Ni 3 S 2 @Ni(OH) 2 /3DGN composites (3DGN=three-dimensional graphene network). In addition, the as-fabricated NF-NN-G-5mg composite electrode has an excellent cycle life with no capacitance loss after 3000 cycles, indicating a potential application as an efficient electrode. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Fabrication of ordered Fe–Ni nitride film with equiatomic Fe/Ni ratio

    NASA Astrophysics Data System (ADS)

    Takata, Fumiya; Ito, Keita; Suemasu, Takashi

    2018-05-01

    We successfully grew a single-phase tetragonal FeNiN film with an equiatomic ratio of Fe, Ni, and N on a MgO(001) substrate by molecular beam epitaxy. We then demonstrated the formation of Fe2Ni2N films by extracting N atoms from the FeNiN film. These results suggested that Fe and Ni atoms in the Fe2Ni2N film were L10-ordered along the film plane direction because of the a-axis orientation growth of the FeNiN film on the MgO(001) substrate.

  12. Instrumental head impulse test changes after intratympanic gentamicin for unilateral definite Ménière's disease: A systematic review and meta-analysis.

    PubMed

    Marques, Pedro Santos; Dias, Claudia Camila; Perez-Fernandez, Nicolas; Spratley, Jorge

    2018-02-02

    To estimate how much could intratympanic gentamicin (ITG) interfere with the vestibular-ocular reflex (VOR) parameters on instrumental head impulse test (HIT), either with scleral search coil or video head impulse test and, eventually, foresee the control of vertigo crisis in unilateral intractable Ménière's disease (MD). A literature search was conducted in PubMed, Scopus, Web of Science and Cochrane search engines. The search terms used were "vestibular ocular reflex", "head impulse test", "gentamicin," and "Meniere's disease". Limitations included text availability to be full text, species to be humans and language to be English. All study types were included. 89 articles were screened identifying four eligible studies were identified. Studies were included after consensus of the authors. Meta-analysis was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Data was analysed using Review Manager software. Instrumental HIT, after ITG for MD, demonstrated, in the treated ear, a decreased gain in the horizontal, posterior and superior semicircular canals (SCC), of 0.36 (0.26; 0.47; 95% CI), 0.35 (0.22; 0.48; 95% CI) and 0.28 (0.21; 0.35; 95% CI), respectively. Gain asymmetry increases between the treated and non-treated ear of 23.78 (7.22; 40.35; 95% CI), 32.01 (12.27; 51.76; 95% CI) and 17.49 (9.99; 24.99; 95% CI), were similarly detected in the horizontal, posterior and superior SCC, respectively. Significantly smaller gain values after the first treatment were observed for a single injection group versus multiple injection group in the horizontal (p=0.002) and superior SCCs (p=0.016). Instrumental HIT is effective in evaluating the SCC function after ITG for intractable unilateral MD. VOR gain changes in the direction of the treated ear in the three SCC have been clearly registered. An increased reduction of the VOR gain in the horizontal and anterior SCC also seemed to foresee the control of vertigo

  13. Preparation and characterization of Ni-P/Ni3.1B composite alloy coatings

    NASA Astrophysics Data System (ADS)

    Wang, Yurong; He, Jiawei; Wang, Wenchang; Shi, Jianhua; Mitsuzaki, Naotoshi; Chen, Zhidong

    2014-02-01

    The preparation of Ni-P/Ni3.1B composite alloy coating on the surface of copper was achieved by co-deposition of Ni3.1B nanoparticles with Ni-P coating during electroless plating. Ni-P-B alloy coating was obtained by heat-treating the as-plated Ni-P/Ni3.1B composite coating. The effect of the concentration of sodium alginate, borax, thiourea, Ni3.1B, temperature, and pH value on the deposition rate and B content were investigated and determined to be: 30 g L-1, 10 g L-1, 2 mg L-1, 20 mg L-1, 70 °C and 9.0 , respectively. Sodium alginate and thiourea were played as surfactant for coating Ni3.1B nanoparticles and stabilizer for the plating bath, respectively. Ni-P/Ni3.1B composite coating had good performance such as corrosion resistance and solderability.

  14. Asymmetrical interfacial reactions of Ni/SAC101(NiIn)/Ni solder joint induced by current stressing

    NASA Astrophysics Data System (ADS)

    Lin, Chen-Yi; Chiu, Tsung-Chieh; Lin, Kwang-Lung

    2018-03-01

    An electric current can asymmetrically trigger either atomic migration or interfacial reactions between a cathode and an anode. The present study investigated the dissolution of metallization and formation of an interfacial intermetallic compound (IMC) in the Cu/Ni/Sn1.0Ag0.1Cu0.02Ni0.05In/Ni/Cu solder joint at various current densities in the order of 103 A/cm2 at temperatures ranging from 100 °C to 150 °C. The polarization behavior of Ni dissolution and IMC formation under current stressing were systematically investigated. The asymmetrical interfacial reactions of the solder joint were found to be greatly influenced by ambient temperature. The dissolution of Ni and its effect on interfacial IMC formation were also discussed.

  15. Selection and utilization of assessment instruments in substance abuse treatment trials: the National Drug Abuse Treatment Clinical Trials Network experience.

    PubMed

    Rosa, Carmen; Ghitza, Udi; Tai, Betty

    2012-07-17

    Based on recommendations from a US Institute of Medicine report, the National Institute on Drug Abuse established the National Drug Abuse Treatment Clinical Trials Network (CTN) in 1999, to accelerate the translation of science-based addiction treatment research into community-based practice, and to improve the quality of addiction treatment, using science as the vehicle. One of the CTN's primary tasks is to serve as a platform to forge bi-directional communications and collaborations between providers and scientists, to enhance the relevance of research, which generates empirical results that impact practice. Among many obstacles in moving research into real-world settings, this commentary mainly describes challenges and iterative experiences in regard to how the CTN develops its research protocols, with focus on how the CTN study teams select and utilize assessment instruments, which can reasonably balance the interests of both research scientists and practicing providers when applied in CTN trials. This commentary also discusses the process by which the CTN further selects a core set of common assessment instruments that may be applied across all trials, to allow easier cross-study analyses of comparable data.

  16. Shaping ability of two M-wire and two traditional nickel-titanium instrumentation systems in S-shaped resin canals.

    PubMed

    Ceyhanli, K T; Kamaci, A; Taner, M; Erdilek, N; Celik, D

    2015-01-01

    The aim of this study was to evaluate the shaping effects of two M-wire and two traditional nickel-titanium (NiTi) rotary systems in simulated S-shaped resin canals. Forty simulated S-shaped canals in resin blocks were instrumented with two traditional (ProTaper, Sendoline S5) and two M-wire (WaveOne, GT series X) NiTi systems according to the manufacturers' instructions. Ten resin blocks were used for each system. Pre- and post-instrumentation images were captured using a stereomicroscope and superimposed with an image program. Canal transportation, material removal, and aberrations were evaluated and recorded as numeric parameters. Data were analyzed using one-way ANOVA and post-hoc Tukey tests with a 95% confidence interval. There were significant differences between systems in terms of transportation and material removal (P<0.05). Coronal danger zone was the most common aberration. Within the limits of this ex vivo study, it was found that the manufacturing methods (M-wire or traditional NiTi) and kinematics (rotary or reciprocating motion) did not affect the shaping abilities of the systems. The extended file designs of highly tapered NiTi systems (ProTaper, WaveOne) resulted in greater deviations from the original root canal trace and more material removal when compared to less tapered systems (Sendoline S5, GT series X).

  17. A new method for the assessment of the surface topography of NiTi rotary instruments.

    PubMed

    Ferreira, F; Barbosa, I; Scelza, P; Russano, D; Neff, J; Montagnana, M; Zaccaro Scelza, M

    2017-09-01

    To describe a new method for the assessment of nanoscale alterations in the surface topography of nickel-titanium endodontic instruments using a high-resolution optical method and to verify the accuracy of the technique. Noncontact three-dimensional optical profilometry was used to evaluate defects on a size 25, .08 taper reciprocating instrument (WaveOne ® ), which was subjected to a cyclic fatigue test in a simulated root canal in a clear resin block. For the investigation, an original procedure was established for the analysis of similar areas located 3 mm from the tip of the instrument before and after canal preparation to enable the repeatability and reproducibility of the measurements with precision. All observations and analysis were taken in areas measuring 210 × 210 μm provided by the software of the equipment. The three-dimensional high-resolution image analysis showed clear alterations in the surface topography of the examined cutting blade and flute of the instrument, before and after use, with the presence of surface irregularities such as deformations, debris, grooves, cracks, steps and microcavities. Optical profilometry provided accurate qualitative nanoscale evaluation of similar surfaces before and after the fatigue test. The stability and repeatability of the technique enables a more comprehensive understanding of the effects of wear on the surface of endodontic instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  18. First-principle calculation on mechanical and thermal properties of B2-NiSc with point defects

    NASA Astrophysics Data System (ADS)

    Yuan, Zhipeng; Cui, Hongbao; Guo, Xuefeng

    2017-01-01

    Using the first-principles plane-wave pseudo-potential method based on density functional theory, the effect of vacancy and anti-position defect on the mechanical and thermal properties of B2-NiSc intermetallics were discussed in detail. Several parameters, such as the shear modulus, bulk modulus, modulus of elasticity, C 11-C 11, the Debye temperature and Poisson's ratio, have been calculated to evaluate the effect of vacancy and anti-position defect on the hardness, ductility and thermal properties of B2-NiSc intermetallics. The results show that VNi, ScNi, VSc and NiSc the four point defects all make the crystal hardness decrease and improve plasticity of B2-NiSc intermetallics. The entropy, enthalpy and free energy of VNi, ScNi, VSc and NiSc are monotonously changed as temperature changes. From the perspective of free energy, NiSc is the most stable, while ScNi is the most unstable. Debye temperature of NiSc intermetallics with four different point defects shows VNi, ScNi, VSc and NiSc the four point defects all reduce the stability of B2-NiSc intermetallics. Project supported by the National Natural Science Foundation of China (Nos. 51301063, 51571086) and the Talent Introduction Foundation of Henan Polytechnic University (No. Y-2009).

  19. Synthesis and catalytic performance of SiO2@Ni and hollow Ni microspheres

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Liu, Yanhua; Shi, Xueting; Yu, Zhengyang; Feng, Libang

    2016-11-01

    Nickel (Ni) catalyst has been widely used in catalytic reducing reactions such as catalytic hydrogenation of organic compounds and catalytic reduction of organic dyes. However, the catalytic efficiency of pure Ni is low. In order to improve the catalytic performance, Ni nanoparticle-loaded microspheres can be developed. In this study, we have prepared Ni nanoparticle-loaded microspheres (SiO2@Ni) and hollow Ni microspheres using two-step method. SiO2@Ni microspheres with raspberry-like morphology and core-shell structure are synthesized successfully using SiO2 microsphere as a template and Ni2+ ions are adsorbed onto SiO2 surfaces via electrostatic interaction and then reduced and deposited on surfaces of SiO2 microspheres. Next, the SiO2 cores are removed by NaOH etching and the hollow Ni microspheres are prepared. The NaOH etching time does no have much influence on the crystal structure, shape, and surface morphology of SiO2@Ni; however, it can change the phase composition evidently. The hollow Ni microspheres are obtained when the NaOH etching time reaches 10 h and above. The as-synthesized SiO2@Ni microspheres exhibit much higher catalytic performance than the hollow Ni microspheres and pure Ni nanoparticles in the catalytic reduction of methylene blue. Meanwhile, the SiO2@Ni catalyst has high stability and hence it can be recycled for reuse.

  20. Directional Solidification and Mechanical Properties of NiAl-NiAlTa Alloys

    NASA Technical Reports Server (NTRS)

    Johnson, D. R.; Chen, X. F.; Oliver, B. F.; Noebe, R. D.; Whittenberger, J. D.

    1995-01-01

    Directional solidification of eutectic alloys is a promising technique for producing in-situ composite materials exhibiting a balance of properties. Consequently, the microstructure, creep strength and fracture toughness of directionally solidified NiAl-NiAlTa alloys were investigated. Directional solidification was performed by containerless processing techniques to minimize alloy contamination. The eutectic composition was found to be NiAl-15.5 at% Ta and well-aligned microstructures were produced at this composition. A near-eutectic alloy of NiAl-14.5Ta was also investigated. Directional solidification of the near-eutectic composition resulted in microstructures consisting of NiAl dendrites surrounded by aligned eutectic regions. The off-eutectic alloy exhibited promising compressive creep strengths compared to other NiAl-based intermetallics, while preliminary testing indicated that the eutectic alloy was competitive with Ni-base single crystal superalloys. The room temperature toughness of these two-phase alloys was similar to that of polycrystalline NiAl even with the presence of the brittle Laves phase NiAlTa.

  1. Hierarchical NiCo2 S4 Nanotube@NiCo2 S4 Nanosheet Arrays on Ni Foam for High-Performance Supercapacitors.

    PubMed

    Chen, Haichao; Chen, Si; Shao, Hongyan; Li, Chao; Fan, Meiqiang; Chen, Da; Tian, Guanglei; Shu, Kangying

    2016-01-01

    Hierarchical NiCo2 S4 nanotube@NiCo2 S4 nanosheet arrays on Ni foam have been successfully synthesized. Owing to the unique hierarchical structure, enhanced capacitive performance can be attained. A specific capacitance up to 4.38 F cm(-2) is attained at 5 mA cm(-2) , which is much higher than the specific capacitance values of NiCo2 O4 nanosheet arrays, NiCo2 S4 nanosheet arrays and NiCo2 S4 nanotube arrays on Ni foam. The hierarchical NiCo2 S4 nanostructure shows superior cycling stability; after 5000 cycles, the specific capacitance still maintains 3.5 F cm(-2) . In addition, through the morphology and crystal structure measurement after cycling stability test, it is found that the NiCo2 S4 electroactive materials are gradually corroded; however, the NiCo2 S4 phase can still be well-maintained. Our results show that hierarchical NiCo2 S4 nanostructures are suitable electroactive materials for high performance supercapacitors. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Implement trigger for a NI data acquisition card PCI 5105 in the measurement studio development environment for a high speed demodulator based on fiber Fabry-Pérot tunable filter (FFP-TF)

    NASA Astrophysics Data System (ADS)

    Zhang, Hongtao; Yang, Shangming; Fan, Lingling; Wang, Pengfei; Zhao, Xilin; Wang, Zhenhua; Cui, Hong-Liang

    2010-04-01

    In this paper we report a scheme of low-cost, small-size differential electrical converter to change analog trigger signals into digital trigger signals. This converter successfully resolves the incompatibility between the digital trigger mode of NI (National Instruments) data acquisition card PCI 5105 in Measurement Studio development environment for a demodulator and the requirement from instability of spectra of fiber Bragg grating (FBG) sensors. The instability is caused by intrinsic drifts of FFP-TF inside this high speed demodulator. The obtained results of frequency response about the converter have clearly demonstrated that this method is effective when the frequency of trigger signal is less than 3,000 Hz. This converter can satisfy the current requirements of demodulator based on FFP-TF, since mostly actual working scanning frequency of FFP-TF is less than 1,000 Hz. This method may be recommended to resolve similar problems for other NI customers who have developed their data acquisition system based on Measurement Studio.

  3. Viscosities of Fe Ni, Fe Co and Ni Co binary melts

    NASA Astrophysics Data System (ADS)

    Sato, Yuzuru; Sugisawa, Koji; Aoki, Daisuke; Yamamura, Tsutomu

    2005-02-01

    Viscosities of three binary molten alloys consisting of the iron group elements, Fe, Ni and Co, have been measured by using an oscillating cup viscometer over the entire composition range from liquidus temperatures up to 1600 °C with high precision and excellent reproducibility. The viscosities measured showed good Arrhenius linearity for all the compositions. The viscosities of Fe, Ni and Co as a function of temperature are as follows: \\eqalign{ & \\log \\eta={-}0.6074 + 2493/T\\qquad for\\quad Fe\\\\ & \\log \\eta={-}0.5695 + 2157/T\\qquad for\\quad Ni \\\\ & \\log \\eta={-}0.6620 + 2430/T\\qquad for\\quad Co.} The isothermal viscosities of Fe-Ni and Fe-Co binary melts increase monotonically with increasing Fe content. On the other hand, in Ni-Co binary melt, the isothermal viscosity decreases slightly and then increases with increasing Co. The activation energy of Fe-Co binary melt increased slightly on mixing, and those of Fe-Ni and Ni-Co melts decreased monotonically with increasing Ni content. The above behaviour is discussed based on the thermodynamic properties of the alloys.

  4. Facile synthesis of Ni/NiO@GO nanocomposites and its enhanced dielectric constant

    NASA Astrophysics Data System (ADS)

    Sarkar, S.; Giri, N.; Mondal, A.; Ray, R.

    2018-05-01

    Ni/NiO embedded Graphene Oxide (GO): Ni/NiO@GO is synthesized by citric acid assisted Pechini-type method. Structural and morphological characterizations are performed by X-ray powdered diffraction (XRD), field emission scanning electron microscopy (FESEM) and tunneling electron microscopy (TEM). Defects in GO sheets are probed by RAMAN spectroscopy. The temperature variation of dielectric constant (ɛR) and dielectric loss (tan δ) are investigated in the temperature range 300 - 400 K. Decoration of GO with Ni/NiO nanoparticles enhances its ɛR by˜55 times. Moreover, its dielectric constant measured at 5 MHz is found to be˜430 times to that of Ni/NiO along with the reduction of dielectric loss by a factor˜0.5. The enhanced dielectric constant makes the composite Ni/NiO@GO a potential candidate for using in ecologically friendly energy storage devices.

  5. A magnetostructural study of linear NiII MnIII NiII, NiII CrIII NiII and triangular Ni(II)3 species containing (pyridine-2-aldoximato)nickel(II) unit as a building block.

    PubMed

    Weyhermüller, Thomas; Wagner, Rita; Khanra, Sumit; Chaudhuri, Phalguni

    2005-08-07

    Three trinuclear complexes, NiII MnIII NiII, NiII CrIII NiII and Ni(II)3 based on (pyridine-2-aldoximato)nickel(II) units are described. Two of them, and , contain metal-centers in linear arrangement, as is revealed by X-ray diffraction. Complex is a homonuclear complex in which the three nickel(II) centers are disposed in a triangular fashion. The compounds were characterized by various physical methods including cyclic voltammetric and variable-temperature (2-290 K) susceptibility measurements. Complexes and display antiferromagnetic exchange coupling of the neighbouring metal centers, while weak ferromagnetic spin exchange between the adjacent Ni II and Cr III ions in is observed. The experimental magnetic data were simulated by using appropriate models.

  6. Kinetics of NiO and NiCl2 Hydrogen Reduction as Precursors and Properties of Produced Ni/Al2O3 and Ni-Pd/Al2O3 Catalysts

    PubMed Central

    Sokić, Miroslav; Kamberović, Željko; Nikolić, Vesna; Marković, Branislav; Korać, Marija; Anđić, Zoran; Gavrilovski, Milorad

    2015-01-01

    The objects of this investigation were the comparative kinetic analysis of the NiO and NiCl2 reduction by hydrogen during an induction period and elimination of the calcination during the synthesis of Ni/Al2O3 catalysts. The effect of temperature and time on NiO and NiCl2 reduction degrees was studied. Avrami I equation was selected as the most favorable kinetic model and used to determine activation energy of the NiO and NiCl2 reduction for the investigated temperature range (623–923 K) and time intervals (1–5 minutes). The investigation enabled reaching conclusions about the reaction ability and rate of the reduction processes. Afterward, Ni/Al2O3 catalysts were obtained by using oxide and chloride precursor for Ni. The catalysts were supported on alumina-based foam and prepared via aerosol route. Properties of the samples before and after low-temperature hydrogen reduction (633 K) were compared. Obtained results indicated that the synthesis of Ni/Al2O3 catalysts can be more efficient if chloride precursor for Ni is directly reduced by hydrogen during the synthesis process, without the calcination step. In addition, Ni-Pd/Al2O3 catalysts with different metal content were prepared by using chloride precursors. Lower reduction temperature was utilized and the chlorides were almost completely reduced at 533 K. PMID:25789335

  7. Preferential diffusion in concentrated solid solution alloys: NiFe, NiCo and NiCoCr

    DOE PAGES

    Zhao, Shijun; Osetsky, Yuri; Zhang, Yanwen

    2017-02-13

    In single-phase concentrated solid-solution alloys (CSAs), including high entropy alloys (HEAs), remarkable mechanical properties are exhibited, as well as extraordinary corrosion and radiation resistance compared to pure metals and dilute alloys. But, the mechanisms responsible for these properties are unknown in many cases. In this work, we employ ab initio molecular dynamics based on density functional theory to study the diffusion of interstitial atoms in Ni and Ni-based face-centered cubic CSAs including NiFe, NiCo and NiCoCr. We model the defect trajectories over >100 ps and estimate tracer diffusion coefficients, correlation factors and activation energies. Furthermore, we found that the diffusionmore » mass transport in CSAs is not only slower than that in pure components, i.e. sluggish diffusion, but also chemically non-homogeneous. The results obtained here can be used in understanding and predicting the atomic segregation and phase separation in CSAs under irradiation conditions.« less

  8. Effects of Ni particle morphology on cell performance of Na/NiCl2 battery

    NASA Astrophysics Data System (ADS)

    Kim, Mangi; Ahn, Cheol-Woo; Hahn, Byung-Dong; Jung, Keeyoung; Park, Yoon-Cheol; Cho, Nam-ung; Lee, Heesoo; Choi, Joon-Hwan

    2017-11-01

    Electrochemical reaction of Ni particle, one of active cathode materials in the Na/NiCl2 battery, occurs on the particle surface. The NiCl2 layer formed on the Ni particle surface during charging can disconnect the electron conduction path through Ni particles because the NiCl2 layer has very low conductivity. The morphology and size of Ni particles, therefore, need to be controlled to obtain high charge capacity and excellent cyclic retention. Effects of the Ni particle size on the cell performance were investigated using spherical Ni particles with diameters of 0.5 μm, 6 μm, and 50 μm. The charge capacities of the cells with spherical Ni particles increased when the Ni particle size becomes smaller because of their higher surface area but their charge capacities were significantly decreased with increasing cyclic tests owing to the disconnection of electron conduction path. The inferior cyclic retention of charge capacity was improved using reticular Ni particles which maintained the reliable connection for the electron conduction in the Na/NiCl2 battery. The charge capacity of the cell with the reticular Ni particles was higher than the cell with the small-sized spherical Ni particles approximately by 26% at 30th cycle.

  9. Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography.

    PubMed

    Mamede-Neto, Iussif; Borges, Alvaro Henrique; Guedes, Orlando Aguirre; de Oliveira, Durvalino; Pedro, Fábio Luis Miranda; Estrela, Carlos

    2017-01-01

    The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05). Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.

  10. NiCrNx interlayer thickness dependence of spectral performance and environmental durability of protected-silver mirrors

    NASA Astrophysics Data System (ADS)

    Xu, Xu; Li, Bincheng; He, Wenyan; Wang, Changjun; Wei, Ming

    2018-04-01

    Gemini-style protected-silver mirror (Sub / NiCrNx / Ag / NiCrNx / SiNx / Air) is a suitable choice for optical instruments requiring both long-term environmental durability and high broadband reflectance. Three Gemini-style protected-silver mirrors with NiCrNx interlayer thicknesses between 0.1 and 0.6 nm were prepared by magnetron sputtering, and the dependences of spectral properties and environmental durability of these protected-silver mirrors on the thickness of NiCrNx interlayer between the silver layer and SiNx layer were investigated in-depth. The reflectance, transmittance and total scattering loss measurements, optical microscope, and scanning electron microscope imaging were employed to characterize the spectral properties and surface morphology, and accelerated environmental tests, including humidity test and salt fog test, were applied to investigate the environmental durability. The experimental results showed that both optical and corrosion-resistant properties of protected-silver mirrors were NiCrNx interlayer thickness dependent, and an optimum NiCrNx interlayer thickness should be ˜0.3 nm for Gemini-style protected-silver mirrors to have reasonably both high reflectance in a broadband spectral range from visible to far infrared and good corrosion resistance for long-lifetime applications in harsh environments.

  11. One dimensional motion of interstitial clusters and void growth in Ni and Ni alloys

    NASA Astrophysics Data System (ADS)

    Yoshiie, T.; Ishizaki, T.; Xu, Q.; Satoh, Y.; Kiritani, M.

    2002-12-01

    One dimensional (1-D) motion of interstitial clusters is important for the microstructural evolution in metals. In this paper, the effect of 2 at.% alloying with elements Si (volume size factor to Ni: -5.81%), Cu (7.18%), Ge (14.76%) and Sn (74.08%) in Ni on 1-D motion of interstitial clusters and void growth was studied. In neutron irradiated pure Ni, Ni-Cu and Ni-Ge, well developed dislocation networks and voids in the matrix, and no defects near grain boundaries were observed at 573 K to a dose of 0.4 dpa by transmission electron microscopy. No voids were formed and only interstitial type dislocation loops were observed near grain boundaries in Ni-Si and Ni-Sn. The reaction kinetics analysis which included the point defect flow into planar sink revealed the existence of 1-D motion of interstitial clusters in Ni, Ni-Cu and Ni-Ge, and lack of such motion in Ni-Si and Ni-Sn. In Ni-Sn and Ni-Si, the alloying elements will trap interstitial clusters and thereby reduce the cluster mobility, which lead to the reduction in void growth.

  12. Comparative study of 6 rotary nickel-titanium systems and hand instrumentation for root canal preparation in severely curved root canals of extracted teeth.

    PubMed

    Celik, Davut; Taşdemir, Tamer; Er, Kürşat

    2013-02-01

    Some improvements have been developed with new generations of nickel-titanium (NiTi) rotary instruments that led to their successful and extensive application in clinical practice. The purpose of this in vitro study was to compare the root canal preparations performed by using GT Series X and Twisted File systems produced by innovative manufacturing process with Revo-S, RaCe, Mtwo, and ProTaper Universal systems manufactured directly from conventional nitinol and with stainless steel K-Flexofile instruments. The mesiobuccal root canals of 140 maxillary first permanent molars that had between 30°-40° curvature angle and 4- to 9-mm curvature radius of the root canal were used. After root canal preparations made by using GT Series X, Twisted File, Revo-S, RaCe, Mtwo, and ProTaper Universal NiTi rotary systems and stainless steel K-Flexofile instruments, transportation occurred in the root canal, and alteration of working length (WL) was assessed by using a modified double-digital radiographic technique. The data were compared by the post hoc Tukey honestly significant difference test. NiTi rotary systems caused less canal transportation and alteration of WL than K-Flexofile instruments (P < .05). There was no significant difference between NiTi rotary system groups at any levels (P > .05) except 2.5 mm from the WL. At this level ProTaper Universal system caused significant canal transportation (P < .05). GT Series X and Twisted File rotary systems produced with innovative process were concluded to shape the curved canals to result in minimal canal transportation, similar to Revo-S, RaCe, Mtwo, and ProTaper Universal rotary systems manufactured by traditional methods. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Thermodynamic characterization of Ni3TeO6, Ni2Te3O8 and NiTe2O5

    NASA Astrophysics Data System (ADS)

    Dawar, Rimpi; Babu, R.; Ananthasivan, K.; Anthonysamy, S.

    2017-09-01

    Measurement of vapour pressure of TeO2(g) over the biphasic mixture Ni3TeO6 (s) + NiO(s) in the temperature range 1143-1272 K was carried out using transpiration-thermogravimetric technique (TTG). Gibbs energy of formation of Ni3TeO6 was obtained from the temperature dependence of vapour pressure of TeO2 (g) generated by the incongruent vapourisation reaction, Ni3TeO6 (s) → NiO(s) + TeO2 (g) + 1/2 O2 in the temperature range 1143-1272 K. An isoperibol type drop calorimeter was used to measure the enthalpy increments of Ni3TeO6, Ni2Te3O8 and NiTe2O5. Thermodynamic functions viz., heat capacity, entropy and Gibbs energy functions of these compounds were derived from the experimentally measured enthalpy increment values. Third-law analysis was carried out to ascertain absence of temperature dependent systematic errors in the measurement of vapour pressure of TeO2 (g). A value of -1265.1 ± 1.5 kJ mol-1 was obtained for Δ Hf,298K o (Ni3TeO6) using third-law analysis.

  14. Spinal Stabilization Using Orthopedic Extremity Instrumentation Sets During Operation Enduring Freedom-Afghanistan.

    PubMed

    Ravindra, Vijay M; Wallace, Scott A; Vaidya, Rahul; Fox, W Christopher; Klugh, Arnett R; Puskas, David; Park, Min S

    2016-02-01

    The Role III, Multinational Medical Unit at Kandahar Air Field, Afghanistan, was established to provide combat casualty care in theater for International Security Assistance Forces, Afghanistan National Security Forces, and local nationals during Operation Enduring Freedom-Afghanistan. The authors describe their experience of treating unstable lumbar spine fractures with orthopedic extremity instrumentation sets from January 2007 to January 2008 and November 2010 to May 2011. During the study periods, 15 patients comprising Afghanistan National Security Forces and local nationals presented to the medical facility for treatment of unstable lumbar spine fractures. The patients underwent surgery for either anterior corpectomy and instrumented fusion (n = 5) or posterior instrumented fusion (n = 10). Because of periodic scarcity of spinal instrumentation sets, orthopedic extremity instrumentation sets were used (Synthes Large Fragment LCP Instrument and Implant Set) for spinal stabilization. Immediate postoperative standing and sitting plain radiographs demonstrated no evidence of fracture progression or immediate hardware failure. One patient was seen in follow-up at 4 weeks and demonstrated construct stability on follow-up radiographs. In the combat environment with sparse resources, unstable spine fractures may potentially be treated using instrumentation not specifically designed for spinal implantation. This is an off-label use, and the authors do not recommend the use of these techniques as standard treatment in most medical environments. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Kids with disabilities inspire a musical instrument

    ScienceCinema

    Daily, Dan; Pfeifer, Kent

    2018-02-14

    The Midiwing is a musical instrument that unites music and computer technology for those who lack the experience, physical ability, or maturity to play music with traditional instruments. To create the instrument, Dan Daily, Director of Musicode Innovations, reworked and recoded Musical Instrument Digital Interface (MIDI) technology and introduced ergonomic design. He applied to the New Mexico Small Business Assistance (NMSBA) Program to receive help when he discovered the microcontroller he used was being phased out. Daily and Kent Pfeifer, an engineer at Sandia National Laboratories and musician himself, partnered to create a new state-of-the-art design.

  16. Kids with disabilities inspire a musical instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daily, Dan; Pfeifer, Kent

    The Midiwing is a musical instrument that unites music and computer technology for those who lack the experience, physical ability, or maturity to play music with traditional instruments. To create the instrument, Dan Daily, Director of Musicode Innovations, reworked and recoded Musical Instrument Digital Interface (MIDI) technology and introduced ergonomic design. He applied to the New Mexico Small Business Assistance (NMSBA) Program to receive help when he discovered the microcontroller he used was being phased out. Daily and Kent Pfeifer, an engineer at Sandia National Laboratories and musician himself, partnered to create a new state-of-the-art design.

  17. Superaerophobic P-doped Ni(OH)2/NiMoO4 hierarchical nanosheet arrays grown on Ni foam for electrocatalytic overall water splitting.

    PubMed

    Xi, Wenguang; Yan, Gang; Tan, Huaqiao; Xiao, Liguang; Cheng, Sihang; Khan, Shifa Ullah; Wang, Yonghui; Li, Yangguang

    2018-06-19

    Transition metal (TM) oxides and hydroxides are one of the important candidates for the development of durable and low-cost electrocatalysts towards water splitting. The key issue is exploring effective methods to improve their electrocatalytic activity. Herein, we report a new type of P-doped Ni(OH)2/NiMoO4 hierarchical nanosheet array (abbr. P-Ni(OH)2/NiMoO4) grown on Ni foam (NF), which can act as a highly efficient electrocatalyst towards overall water splitting. Such a composite was obtained by a three-step preparation process. In the first two hydrothermal reactions, the crystalline Ni(OH)2 hierarchical nanosheet arrays were grown on NF and then the low crystallinity NiMoO4 was grafted on the Ni(OH)2 nanosheets. In the third phosphorization step, P element was doped into the composite Ni(OH)2/NiMoO4. Electrocatalytic experiments show that P-Ni(OH)2/NiMoO4 possesses a smaller overpotential (60 mV) and lower Tafel slope (130 mV dec-1) toward HER in 1 M KOH. When it was employed as an integrated water splitting catalyst, only a potential of 1.55 V was required to achieve a current density of 10 mA cm-2. This catalytic activity is even better than those of electrolyzers constructed with noble metals Pt/C∥IrO2. The superior electrocatalytic performance of P-Ni(OH)2/NiMoO4 can be attributed to the high quality of crystalline Ni(OH)2 nanosheet arrays grown on NF, which dramatically improve the conductivity. Furthermore, the hierarchical structure not only increases the surface area and exposes more catalytically active sites, but also provides a superaerophobic surface, which helps to accelerate the release of generated bubbles. Moreover, the synergistic effects between P-Ni(OH)2 and P-NiMoO4 efficiently promote the HER and OER processes also. This work may suggest new a way to explore TM oxide/hydroxide-based durable electrocatalysts with highly efficient electrocatalytic activities towards overall water splitting.

  18. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine.

    PubMed

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-05-01

    To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure ( p =0.049 and 0.050, respectively). When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion.

  19. Water dissociation on Ni(100), Ni(110), and Ni(111) surfaces: Reaction path approach to mode selectivity

    DOE PAGES

    Seenivasan, H.; Jackson, Bret; Tiwari, Ashwani K.

    2017-02-17

    We performed a comparative study of mode-selectivity of water dissociation on Ni(100), Ni(110), and Ni(111) surfaces at the same level of theory using a fully quantum approach based on the reaction path Hamiltonian. Calculations show that the barrier to water dissociation on the Ni(110) surface is significantly lower compared to its close-packed counterparts. Transition states for this reaction on all three surfaces involve the elongation of one of the O–H bonds. Furthermore, a significant decrease in the symmetric stretching and bending mode frequencies near the transition state is observed in all three cases and in the vibrational adiabatic approximation, excitationmore » of these softened modes results in a significant enhancement in reactivity. Inclusion of non-adiabatic couplings between modes results in the asymmetric stretching mode showing a similar enhancement of reactivity as the symmetric stretching mode. Dissociation probabilities calculated at a surface temperature of 300 K showed higher reactivity at lower collision energies compared to that of the static surface case, underlining the importance of lattice motion in enhancing reactivity. Mode selective behavior is similar on all the surfaces. Molecules with one-quantum of vibrational excitation in the symmetric stretch, at lower energies (up to 0.45 eV), are more reactive on Ni(110) than the Ni(100) and Ni(111) surfaces. But, the dissociation probabilities approach saturation on all the surfaces at higher incident energy values. Ultimately, Ni(110) is found to be highly reactive toward water dissociation among the low-index nickel surfaces owing to a low reaction barrier resulting from the openness and corrugation of the surface. These results show that the mode-selective behavior does not vary with different crystal facets of Ni qualitatively, but there is a significant quantitative effect.« less

  20. Water dissociation on Ni(100), Ni(110), and Ni(111) surfaces: Reaction path approach to mode selectivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seenivasan, H.; Jackson, Bret; Tiwari, Ashwani K.

    We performed a comparative study of mode-selectivity of water dissociation on Ni(100), Ni(110), and Ni(111) surfaces at the same level of theory using a fully quantum approach based on the reaction path Hamiltonian. Calculations show that the barrier to water dissociation on the Ni(110) surface is significantly lower compared to its close-packed counterparts. Transition states for this reaction on all three surfaces involve the elongation of one of the O–H bonds. Furthermore, a significant decrease in the symmetric stretching and bending mode frequencies near the transition state is observed in all three cases and in the vibrational adiabatic approximation, excitationmore » of these softened modes results in a significant enhancement in reactivity. Inclusion of non-adiabatic couplings between modes results in the asymmetric stretching mode showing a similar enhancement of reactivity as the symmetric stretching mode. Dissociation probabilities calculated at a surface temperature of 300 K showed higher reactivity at lower collision energies compared to that of the static surface case, underlining the importance of lattice motion in enhancing reactivity. Mode selective behavior is similar on all the surfaces. Molecules with one-quantum of vibrational excitation in the symmetric stretch, at lower energies (up to 0.45 eV), are more reactive on Ni(110) than the Ni(100) and Ni(111) surfaces. But, the dissociation probabilities approach saturation on all the surfaces at higher incident energy values. Ultimately, Ni(110) is found to be highly reactive toward water dissociation among the low-index nickel surfaces owing to a low reaction barrier resulting from the openness and corrugation of the surface. These results show that the mode-selective behavior does not vary with different crystal facets of Ni qualitatively, but there is a significant quantitative effect.« less

  1. Instrumentation for Monitoring around Marine Renewable Energy Converters: Workshop Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polagye, B. L.; Copping, A. E.; Brown-Saracino, J.

    2014-01-14

    To better understand the state of instrumentation and capabilities for monitoring around marine energy converters, the U.S. Department of Energy directed Pacific Northwest National Laboratory and the Northwest National Marine Renewable Energy Center at the University of Washington to convene an invitation-only workshop of experts from around the world to address instrumentation needs.

  2. Structural and magnetic properties of Ni-Zn and Ni-Zn-Co ferrites

    NASA Astrophysics Data System (ADS)

    Knyazev, A. V.; Zakharchuk, I.; Lähderanta, E.; Baidakov, K. V.; Knyazeva, S. S.; Ladenkov, I. V.

    2017-08-01

    Ni-Zn and Ni-Zn-Co ferrite powders with nominal compositions Ni0.5Zn0.5Fe2O4 and Ni0.5Zn0.3Co0.2Fe2O4 were prepared by the solid-state reaction synthesis with periodic regrinding during the calcination at 1073 K. The structure of Ni0.5Zn0.5Fe2O4 and Ni0.5Zn0.3Co0.2Fe2O4 was refined assuming space group F d-3m. Scanning electron microscopy revealed the average sizes of the crystalline ferrite particles are 130-630 nm for Ni0.5Zn0.5Fe2O4 and 140-350 nm for Ni0.5Zn0.3Co0.2Fe2O4. The room temperature saturation magnetizations are 59.7 emu/g for Ni0.5Zn0.5Fe2O4 and 57.1 emu/g for Ni0.5Zn0.3Co0.2Fe2O4. The coercivity of the samples is found to be much larger than that of bulk ferrites and increases with Co introduction. The Curie temperature tends to increase upon Zn substitution by Co, as well. The temperature dependences of magnetization measured using zero-field cooled and field cooled protocols exhibit large spin frustration and spin-glass-like behavior.

  3. Comparative effectiveness of NiCl2, Ni- and NiO-NPs in controlling oral bacterial growth and biofilm formation on oral surfaces.

    PubMed

    Khan, Shams Tabrez; Ahamed, Maqusood; Alhadlaq, Hisham A; Musarrat, Javed; Al-Khedhairy, Abdulaziz

    2013-12-01

    Oral ailments are often treated with antibiotics, which are rendered ineffective as bacteria continue to develop resistance against them. It has been suggested that the nanoparticles (NPs) approach may provide a safer and viable alternative to traditional antibacterial agents. Therefore, nickel (Ni)- and nickel oxide (NiO)-NPs were synthesized, characterized and assessed for their efficacy in reducing oral bacterial load in vitro. Also, the effects of bulk compound NiCl2 (Ni ions), along with the Ni- and NiO-NPs on bacterial exopolysaccharide (EPS) production and biofilm formation on the surface of artificial teeth, and acrylic dentures, were investigated. Total bacteria from a healthy male were collected and adjusted to 4×109cells/ml for all the tests. Effect of the NPs on growth, biofilm formation, EPS production and acid production from glucose was tested using standard protocols. Data revealed that the Ni-NPs (average size 41.23nm) exhibited an IC50 value of 73.37μg/ml against total oral bacteria. While, NiO-NPs (average size 35.67nm) were found less effective with much higher IC50 value of 197.18μg/ml. Indeed, the Ni ions exhibited greater biocidal activity with an IC50 value of 70μg/ml. Similar results were obtained with biofilm inhibition on the surfaces of dental prostheses. The results explicitly suggested the effectiveness of tested Ni compounds on the growth of oral bacteria and biofilm formation in the order as NiCl2>Ni-NPs>NiO-NPs. The results elucidated that Ni-NPs could serve as effective nanoantibiotics against oral bacteria. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. 49 CFR 572.21 - Test conditions and instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Test conditions and instrumentation. 572.21 Section 572.21 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY...-Year-Old Child § 572.21 Test conditions and instrumentation. (a)(1) The test probe used for head and...

  5. 49 CFR 572.21 - Test conditions and instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Test conditions and instrumentation. 572.21 Section 572.21 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY...-Year-Old Child § 572.21 Test conditions and instrumentation. (a)(1) The test probe used for head and...

  6. 49 CFR 572.21 - Test conditions and instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Test conditions and instrumentation. 572.21 Section 572.21 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY...-Year-Old Child § 572.21 Test conditions and instrumentation. (a)(1) The test probe used for head and...

  7. 49 CFR 572.21 - Test conditions and instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Test conditions and instrumentation. 572.21 Section 572.21 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY...-Year-Old Child § 572.21 Test conditions and instrumentation. (a)(1) The test probe used for head and...

  8. Electrochemical vs X-ray Spectroscopic Measurements of NiFe(CN)6 Crystals

    NASA Astrophysics Data System (ADS)

    Peecher, Benjamin; Hampton, Jennifer

    Pseudocapacitive materials like hexacyanoferrate have greater energy storage capabilities than standard capacitors while maintaining an ability to charge and discharge quickly. We modify the surface of an electrodeposited Ni thin film with a layer of hexacyanoferrate. Charging and discharging these modified films using cyclic voltammetry (CV) allows us to measure the electrochemically active Fe in the film. To determine how closely this resembles the full amount of Fe in the film, we measure the films' composition using particle-induced x-ray emission (PIXE). We also vary the amount of Ni deposited, both to compare the electrolysis value of charge deposited to the PIXE measurement of Ni in the film, and also to measure how varying the thickness of the Ni surface affects the presence of Fe in the film. Comparisons of the CV and PIXE measurements show agreement in Ni levels but disagreement in Fe levels. PIXE measurements of Fe in the film have positive correlation with Ni in the film. This correlation between PIXE measurements of Ni and Fe suggests that PIXE provides a reliable measure of Fe in the film. This implies that a variable proportion of total Fe in a given film is electrochemically active. This research was made possible by the Hope College Department of Physics Frissel Research Fund and the National Science Foundation under Grants RUI-DMR-1104725, MRI-CHE-0959282, and MRI/RUI-PHY-0319523.

  9. Growth of Ni-Al alloys on Ni(1 1 1), from Al deposits of various thicknesses: (II) Formation of NiAl over a Ni 3Al interfacial layer

    NASA Astrophysics Data System (ADS)

    Le Pévédic, S.; Schmaus, D.; Cohen, C.

    2007-01-01

    This paper describes the second part of a study devoted to the growth of thin Ni-Al alloys after deposition of Al on Ni(1 1 1). In the previous paper [S. Le Pévédic, D. Schmaus, C. Cohen, Surf. Sci. 600 (2006) 565] we have described the results obtained for ultra-thin Al deposits, leading, after annealing at 750 K, to an epitaxial layer of Ni 3Al(1 1 1). In the present paper we show that this regime is only observed for Al deposits smaller than 8 × 10 15 Al/cm 2 and we describe the results obtained for Al deposits exceeding this critical thickness, up to 200 × 10 15 Al/cm 2. Al deposition was performed at low temperature (around 130 K) and the alloying process was followed in situ during subsequent annealing, by Auger electron spectroscopy, low energy electron diffraction and ion beam analysis-channeling measurements, in an ultra-high vacuum chamber connected to a Van de Graaff accelerator. We evidence the formation, after annealing at 750 K, of a crystallographically and chemically well-ordered NiAl(1 1 0) layer (whose thickness depends on the deposited Al amount), over a Ni 3Al "interfacial" layer (whose thickness—about 18 (1 1 1) planes—is independent of the deposited Al amount). The NiAl overlayer is composed of three variants, at 120° from each other in the surface plane, in relation with the respective symmetries of NiAl(1 1 0) and Ni 3Al(1 1 1). The NiAl layer is relaxed (the lattice parameters of cc-B2 NiAl and fcc-L1 2 Ni 3Al differ markedly), and we have determined its epitaxial relationship. In the case of the thickest alloyed layer formed the results concerning the structure of the NiAl layer have been confirmed and refined by ex situ X-ray diffraction and information on its grain size has been obtained by ex situ Atomic Force Microscopy. The kinetics of the alloying process is complex. It corresponds to an heterogeneous growth leading, above the thin Ni 3Al interfacial layer, to a mixture of Al and NiAl over the whole Al film, up to the

  10. Fine Structure in Multi-Phase Zr8Ni21-Zr7Ni10-Zr2Ni7 Alloy Revealed by Transmission Electron Microscope

    PubMed Central

    Shen, Haoting; Bendersky, Leonid A.; Young, Kwo; Nei, Jean

    2015-01-01

    The microstructure of an annealed alloy with a Zr8Ni21 composition was studied by both scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The presence of three phases, Zr8Ni21, Zr2Ni7, and Zr7Ni10, was confirmed by SEM/X-ray energy dispersive spectroscopy compositional mapping and TEM electron diffraction. Distribution of the phases and their morphology can be linked to a multi-phase structure formed by a sequence of reactions: (1) L → Zr2Ni7 + L’; (2) peritectic Zr2Ni7 + L’ → Zr2Ni7 + Zr8Ni21 + L”; (3) eutectic L” → Zr8Ni21 + Zr7Ni10. The effect of annealing at 960 °C, which was intended to convert a cast structure into a single-phase Zr8Ni21 structure, was only moderate and the resulting alloy was still multi-phased. TEM and crystallographic analysis of the Zr2Ni7 phase show a high density of planar (001) defects that were explained as low-energy boundaries between rotational variants and stacking faults. The crystallographic features arise from the pseudo-hexagonal structure of Zr2Ni7. This highly defective Zr2Ni7 phase was identified as the source of the broad X-ray diffraction peaks at around 38.4° and 44.6° when a Cu-K was used as the radiation source. PMID:28793460

  11. Heteromorphic NiCo2S4/Ni3S2/Ni Foam as a Self-Standing Electrode for Hydrogen Evolution Reaction in Alkaline Solution.

    PubMed

    Liu, Hui; Ma, Xiao; Rao, Yuan; Liu, Yang; Liu, Jialiang; Wang, Luyang; Wu, Mingbo

    2018-04-04

    Considerable works have been devoted on developing high-efficiency nonplatinum electrocatalysts for hydrogen evolution reaction (HER). Herein, 3D heteromorphic NiCo 2 S 4 /Ni 3 S 2 nanosheets network has been constructed on Ni foam (denoted as NiCo 2 S 4 /Ni 3 S 2 /NF) serving as a self-standing electrocatalyst through directly thermal sulfurization of a single-source NiCo-layered double hydroxide precursor. The resultant NiCo 2 S 4 /Ni 3 S 2 /NF electrode exhibits outstanding electrocatalytic HER performance with an extremely low onset overpotential of 15 mV and long-term durability in alkaline solution. Such enhanced HER performance can be credited to (1) the massive exposed active sites provided by mixed transition metal chalcogenides (NiCo 2 S 4 and Ni 3 S 2 ), (2) the strong interfacial interaction at NiCo 2 S 4 /Ni 3 S 2 heterojunction interfaces with the strengthened H binding, and (3) the porous highly conductive Ni foam substrate with accelerated electron transfer. This work opens up a new direction to fabricate effective and non-noble-metal electrodes for water splitting and hydrogen generation.

  12. Low-field spin dynamics of Cr7Ni and Cr7Ni-Cu -Cr 7Ni molecular rings as detected by μ SR

    NASA Astrophysics Data System (ADS)

    Sanna, S.; Arosio, P.; Bordonali, L.; Adelnia, F.; Mariani, M.; Garlatti, E.; Baines, C.; Amato, A.; Sabareesh, K. P. V.; Timco, G.; Winpenny, R. E. P.; Blundell, S. J.; Lascialfari, A.

    2017-11-01

    Muon spin rotation measurements were used to investigate the spin dynamics of heterometallic Cr7Ni and Cr7Ni -Cu-Cr7Ni molecular clusters. In Cr7Ni the magnetic ions are arranged in a quasiplanar ring and interact via an antiferromagnetic exchange coupling constant J , while Cr7Ni -Cu-Cr7Ni is composed of two Cr7Ni linked by a bridging moiety containing one Cu ion, that induces an inter-ring ferromagnetic interaction J'≪J . The longitudinal muon relaxation rate λ collected at low magnetic fields μ0H <0.15 Tesla, shows that the two systems present differences in spin dynamics vs temperature. While both samples exhibit a main peak in the muon relaxation rate vs temperature, at T ˜10 K for Cr7Ni and T ˜8 K for Cr7Ni -Cu-Cr7Ni , the two compounds have distinct additional features: Cr7Ni shows a shoulder in λ (T ) for T <8 K, while Cr7Ni -Cu-Cr7Ni shows a flattening of λ (T ) for T <2 K down to temperatures as low as T =20 mK. The main peak of both systems is explained by a Bloembergen-Purcell-Pound (BPP)-like heuristic fitting model that takes into account of a distribution of electronic spin characteristic times for T >5 K, while the shoulder presented by Cr7Ni can be reproduced by a BPP function that incorporates a single electronic characteristic time theoretically predicted to dominate for T <5 K. The flattening of λ (T ) in Cr7Ni -Cu-Cr7Ni occurring at very low temperature can be tentatively attributed to field-dependent quantum effects and/or to an inelastic term in the spectral density of the electronic spin fluctuations.

  13. Test Methods for Telemetry Systems and Subsystems. Volume 1. Test Methods for Vehicle Telemetry Systems

    DTIC Science & Technology

    2006-06-01

    IEC Web Site - http://www.iec.org/ National Instruments Web Site - http://www.ni.com/ ASA ( Acoustical Society of America) - http://asa.aip.org/ Flow...1994 (R2004), Acoustical Terminology. ANSI S1.10-1966 (R2001), USA Standard Method for Calibration of Microphones. ANSI S1.15-1997, USA Standard...R2001), American National Standard Specification for Acoustical Calibrators. ANSI S1.9-1996 (R2001), American National Standard Instruments for

  14. National Aeronautics and Space Administration's research program in earth remote sensing instrumentation

    NASA Technical Reports Server (NTRS)

    Plotkin, Henry H.; Sokoloski, Martin M.; Rubin, Bernard

    1991-01-01

    Terrestrial and atmospheric missions of NASA's program to develop remote sensing instrumentation are described along with several of the instruments and related mission. Systems such as lidar and radar, passive coherent sensors, passive noncoherent sensors, as well as cryogenic cooler technology are discussed.

  15. Preparation and properties of TiC-Ni cermets using Ni-plated TiC

    NASA Astrophysics Data System (ADS)

    Shin, Soon-Gi

    2002-04-01

    TiC powders were coated with Ni by a chemical plating technique and the pressed compacts sintered at 1623K. The density of the sintered bodies was 98-99%. Compared with mechanically-mixed powder, Ni-plated TiC powders gave a more uniform microstructure in which TiC particles were well dispersed in the Ni matrix. The cermets exhibited ductile fracture for TiC-70 vol.% Ni and brittle fracture for TiC-30 vol.% Ni. The flexural strength was improved by the homogeneous dispersion of TiC. The thermal expansion coefficient increased with a decrease in Ni content, following a nearly linear law of mixtures on the basis of volume fractions of pure TiC and Ni.

  16. The MOPITT instrument as a Prototype for Long-Term Space-Based Atmospheric Measurements in the Anthropocene

    NASA Astrophysics Data System (ADS)

    Drummond, James

    2016-07-01

    One of the major characteristics of the Anthropocene will be changes in all the Earth systems on many timescales. Changes that occur within a generation will be very significant for policy decisions and these will require measurements on corresponding timescales from space-based instruments, but these times are long compared to traditional satellite lifetimes. Whether by luck or by good design there are now a number of satellite missions that are recording data over long time periods. With a single instrument, decadal and longer time series of relevant atmospheric parameters have been achieved and the Measurements Of Pollution In The Troposphere (MOPITT) instrument is one such instrument. Launched on 18th December 1999 on the Terra spacecraft, MOPITT has now completed more than 16 years of operation measuring carbon monoxide (CO) over the planet and the mission continues. It is entirely possible that these measurements will span two decades before completion. MOPITT therefore offers a case study of a very long single-instrument time series, albeit one with challenges because this longevity was not part of the original design criteria: The original design specified about a five year life and this has already been considerably exceeded. MOPITT does enable us to look at long term trends and intermittent phenomena over the planet for an extended period of tie encompassing an entire solar cycle and many cycles of El Niño and other quasi-periodic phenomena. This presentation will consider, with examples, some of the advantages and some of the problems of these long-term space measurements with an eye to the future and the needs of future generations. MOPITT was provided to NASA's Terra spacecraft by the Canadian Space Agency and was built by COMDEV of Cambridge, Ontario. Data processing is performed by the MOPITT team at the National Center for Atmospheric Research, Boulder, CO. Instrument control is by the team at the University of Toronto.

  17. Synthesis of a novel Au nanoparticles decorated Ni-MOF/Ni/NiO nanocomposite and electrocatalytic performance for the detection of glucose in human serum.

    PubMed

    Chen, Jingyuan; Xu, Qin; Shu, Yun; Hu, Xiaoya

    2018-07-01

    A nonenzymatic glucose electrochemical sensor was constructed based on Au nanoparticles (AuNPs) decorated Ni metal-organic-framework (MOF)/Ni/NiO nanocomposite. Ni-MOF/Ni/NiO nanocomposite was synthesized by one-step calcination of Ni-MOF. Then AuNPs were loaded onto the Ni-based nanocomposites' surface through electrostatic adsorption. Through characterization by transmission electron microscopy (TEM), high resolution TEM (HRTEM) and energy disperse spectroscopy (EDS) mapping, it is found that the AuNPs were well distributed on the surface of Ni-based nanocomposite. Cyclic voltammetric (CV) study showed the electrocatalytic activity of Au-Ni nanocomposite was highly improved after loading AuNPs onto it. Amperometric study demonstrated that the Au-Ni nanocomposites modified glassy carbon electrode (GCE) exhibited a high sensitivity of 2133.5 mA M -1 cm -2 and a wide linear range (0.4-900 μM) toward the oxidation of glucose with a detection limit as low as 0.1 μM. Moreover, the reproducibility, selectivity and stability of the sensor all exhibited outstanding performance. We applied the as-fabricated high performance sensor to measure the glucose levels in human serum and obtained satisfactory results. It is believed that AuNPs decorated Ni MOF/Ni/NiO nanocomposite provides a new platform for developing highly performance electrochemical sensors in practical applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Anisotropic growth of NiO nanorods from Ni nanoparticles by rapid thermal oxidation.

    PubMed

    Koga, Kenji; Hirasawa, Makoto

    2013-09-20

    NiO nanorods with extremely high crystallinity were grown by rapid thermal oxidation through exposure of Ni nanoparticles (NPs) heated above 400° C to oxygen. Oxidation proceeds by nucleation of a NiO island on a Ni NP that grows anisotropically to produce a NiO nanorod. This process differs completely from that under mild oxidation conditions, where the surface of the NPs is completely covered with an oxide film during the early stage of oxidation. The observed novel behaviour strongly suggests an interfacial oxidation mechanism driven by the dissolution of adsorbed oxygen into the Ni NP sub-surface region, subsequent diffusion and reaction at the NiO/Ni interface. The early oxidation conditions of metal NPs impose a significant influence on the entire oxidation process at the nanoscale and are therefore inherently important for the precise morphological control of oxidized NPs to design functional nanomaterials.

  19. Temperature-dependent selective oxidation processes for Ni-5Cr and Ni-4Al

    DOE PAGES

    Kruska, Karen; Schreiber, Daniel K.; Olszta, Matthew J.; ...

    2018-05-09

    The selective oxidation of Ni-5Cr and Ni-4 Al alloys is evaluated during high (800 °C) and low (420 °C) temperature exposures with the oxygen partial pressure moderated by a Ni/NiO powder buffer. Internal oxidation of Cr and Al is observed throughout the matrix and at grain boundaries at 800 °C accompanied by the ejection of Ni onto the surface for both. At 420 °C, matrix internal oxidation was eliminated and only Ni-4 Al exhibited intergranular (IG) oxidation. Surprisingly, a protective surface oxide rapidly formed for Ni-5Cr blocking IG oxidation. Finally, this is contradictory to results in 330–360 °C hydrogenated watermore » environments where both alloys show IG oxidation.« less

  20. Temperature-dependent selective oxidation processes for Ni-5Cr and Ni-4Al

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruska, Karen; Schreiber, Daniel K.; Olszta, Matthew J.

    The selective oxidation of Ni-5Cr and Ni-4 Al alloys is evaluated during high (800 °C) and low (420 °C) temperature exposures with the oxygen partial pressure moderated by a Ni/NiO powder buffer. Internal oxidation of Cr and Al is observed throughout the matrix and at grain boundaries at 800 °C accompanied by the ejection of Ni onto the surface for both. At 420 °C, matrix internal oxidation was eliminated and only Ni-4 Al exhibited intergranular (IG) oxidation. Surprisingly, a protective surface oxide rapidly formed for Ni-5Cr blocking IG oxidation. Finally, this is contradictory to results in 330–360 °C hydrogenated watermore » environments where both alloys show IG oxidation.« less

  1. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine

    PubMed Central

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-01-01

    Objective To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. Methods We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. Results There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure (p=0.049 and 0.050, respectively). Conclusion When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion. PMID:29631384

  2. Nickel Release, ROS Generation and Toxicity of Ni and NiO Micro- and Nanoparticles

    PubMed Central

    Hedberg, Jonas; Di Bucchianico, Sebastiano; Möller, Lennart; Odnevall Wallinder, Inger; Elihn, Karine; Karlsson, Hanna L.

    2016-01-01

    Occupational exposure to airborne nickel is associated with an elevated risk for respiratory tract diseases including lung cancer. Therefore, the increased production of Ni-containing nanoparticles necessitates a thorough assessment of their physical, chemical, as well as toxicological properties. The aim of this study was to investigate and compare the characteristics of nickel metal (Ni) and nickel oxide (NiO) particles with a focus on Ni release, reactive oxygen species (ROS) generation, cellular uptake, cytotoxicity and genotoxicity. Four Ni-containing particles of both nano-size (Ni-n and NiO-n) and micron-size (Ni-m1 and Ni-m2) were tested. The released amount of Ni in solution was notably higher in artificial lysosomal fluid (e.g. 80–100 wt% for metallic Ni) than in cell medium after 24h (ca. 1–3 wt% for all particles). Each of the particles was taken up by the cells within 4 h and they remained in the cells to a high extent after 24 h post-incubation. Thus, the high dissolution in ALF appeared not to reflect the particle dissolution in the cells. Ni-m1 showed the most pronounced effect on cell viability after 48 h (alamar blue assay) whereas all particles showed increased cytotoxicity in the highest doses (20–40 μg cm2) when assessed by colony forming efficiency (CFE). Interestingly an increased CFE, suggesting higher proliferation, was observed for all particles in low doses (0.1 or 1 μg cm-2). Ni-m1 and NiO-n were the most potent in causing acellular ROS and DNA damage. However, no intracellular ROS was detected for any of the particles. Taken together, micron-sized Ni (Ni-m1) was more reactive and toxic compared to the nano-sized Ni. Furthermore, this study underlines that the low dose effect in terms of increased proliferation observed for all particles should be further investigated in future studies. PMID:27434640

  3. Influence of operator experience on canal preparation time when using the rotary Ni-Ti ProFile system in simulated curved canals.

    PubMed

    Mesgouez, C; Rilliard, F; Matossian, L; Nassiri, K; Mandel, E

    2003-03-01

    The aim of this study was to determine the influence of operator experience on the time needed for canal preparation when using a rotary nickel-titanium (Ni-Ti) system. A total of 100 simulated curved canals in resin blocks were used. Four operators prepared a total of 25 canals each. The operators included practitioners with prior experience of the preparation technique, and practitioners with no experience. The working length for each instrument was precisely predetermined. All canals were instrumented with rotary Ni-Ti ProFile Variable Taper Series 29 engine-driven instruments using a high-torque handpiece (Maillefer, Ballaigues, Switzerland). The time taken to prepare each canal was recorded. Significant differences between the operators were analysed using the Student's t-test and the Kruskall-Wallis and Dunn nonparametric tests. Comparison of canal preparation times demonstrated a statistically significant difference between the four operators (P < 0.001). In the inexperienced group, a significant linear regression between canal number and preparation time occurred. Time required for canal preparation was inversely related to operator experience.

  4. Single-Layer graphene growth on crystalline Ni(111) and Ni(110) and the fate of Carbon on crystalline Ni(100).

    NASA Astrophysics Data System (ADS)

    Araujo, Paulo; Mafra, Daniela; Reina, Alfonso; Shin, Young Cheol; Kim, Ki Kang; Dresselhaus, Mildred; Kong, Jing

    The growth of large area single-layer graphene (1-LG) is studied using ambient pressure CVD on single crystal Ni(111), Ni(110) and Ni(100). By varying both the furnace temperature in the range of 700 - 1100oC and the gas flow through the growth chamber, a uniform growth of high-quality 1-LG is obtained for Ni(111) and Ni(110), but only multilayer graphene (M-LG) growth could be obtained for Ni(100). The experimental results are interpreted to obtain the optimum combination of temperature and gas flow, and the results reported in this manuscript are interpreted through different thermodynamic mechanisms, such as diffusion, segregation and adsorption, which dictate the formation of different carbon structures over the different crystallographic directions of Ni. Characterization with optical microscopy, Raman spectroscopy and optical transmission accordingly support the experimental findings. DOE Award Number DE-SC0001088, College of Arts and Sciences at the University of Alabama, NRF Award Number 2015R1C1A1A02037083 and NSF-DMR 1507806.

  5. Lee Mauldin inspects the National Center for Atmospheric Research CIMS instrument probe on the exterior of NASA's DC-8 flying lab prior to the ARCTAS mission

    NASA Image and Video Library

    2008-03-07

    Climate researchers from the National Center for Atmospheric Research (NCAR) and several universities install and perform functional checkouts of a variety of sensitive atmospheric instruments on NASA's DC-8 airborne laboratory prior to beginning the ARCTAS mission.

  6. Deedee Montzka of the National Center for Atmospheric Research checks out the NOxyO3 instrument on NASA's DC-8 flying laboratory before the ARCTAS mission

    NASA Image and Video Library

    2008-03-07

    Climate researchers from the National Center for Atmospheric Research (NCAR) and several universities install and perform functional checkouts of a variety of sensitive atmospheric instruments on NASA's DC-8 airborne laboratory prior to beginning the ARCTAS mission.

  7. ATR NSUF Instrumentation Enhancement Efforts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joy L. Rempe; Mitchell K. Meyer; Darrell L. Knudson

    A key component of the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) effort is to expand instrumentation available to users conducting irradiation tests in this unique facility. In particular, development of sensors capable of providing real-time measurements of key irradiation parameters is emphasized because of their potential to increase data fidelity and reduce posttest examination costs. This paper describes the strategy for identifying new instrumentation needed for ATR irradiations and the program underway to develop and evaluate new sensors to address these needs. Accomplishments from this program are illustrated by describing new sensors now available to users ofmore » the ATR NSUF. In addition, progress is reported on current research efforts to provide improved in-pile instrumentation to users.« less

  8. A cross-platform GUI to control instruments compliant with SCPI through VISA

    NASA Astrophysics Data System (ADS)

    Roach, Eric; Liu, Jing

    2015-10-01

    In nuclear physics experiments, it is necessary and important to control instruments from a PC, which automates many tasks that require human operations otherwise. Not only does this make long term measurements possible, but it also makes repetitive operations less error-prone. We created a graphical user interface (GUI) to control instruments connected to a PC through RS232, USB, LAN, etc. The GUI is developed using Qt Creator, a cross-platform integrated development environment, which makes it portable to various operating systems, including those commonly used in mobile devices. NI-VISA library is used in the back end so that the GUI can be used to control instruments connected through various I/O interfaces without any modification. Commonly used SCPI commands can be sent to different instruments using buttons, sliders, knobs, and other various widgets provided by Qt Creator. As an example, we demonstrate how we set and fetch parameters and how to retrieve and display data from an Agilent Digital Storage Oscilloscope X3034A with the GUI. Our GUI can be easily used for other instruments compliant with SCPI and VISA with little or no modification.

  9. The reactivity of Fe/Ni colloid stabilized by carboxymethylcellulose (CMC-Fe/Ni) toward chloroform.

    PubMed

    Jin, Xin; Li, Qun; Yang, Qi

    2018-05-16

    The use of stabilizers can prevent the reactivity loss of nanoparticles due to aggregation. In this study, carboxymethylcellulose (CMC) was selected as the stabilizer to synthesize a highly stable CMC-stabilized Fe/Ni colloid (CMC-Fe/Ni) via pre-aggregation stabilization. The reactivity of CMC-Fe/Ni was evaluated via the reaction of chloroform (CF) degradation. The effect of background solution which composition was affected by the preparation of Fe/Ni (Fe/Ni precursors, NaBH 4 dosage) and the addition of solute (common ions, sulfur compounds) on the reactivity of CMC-Fe/Ni was also investigated. Additionally, the dried CMC-Fe/Ni was used for characterization in terms of scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The experimental results indicated that CMC stabilization greatly improved the reactivity of Fe/Ni bimetal and CF (10 mg/L) could be completely degraded by CMC-Fe/Ni (0.1 g/L) within 45 min. The use of different Fe/Ni precursors resulting in the variations of background solution seemed to have no obvious influence on the reactivity of CMC-Fe/Ni, whereas the dosage of NaBH 4 in background solution showed a negative correlation with the reactivity of CMC-Fe/Ni. Besides, the individual addition of external solutes into background solution all had an adverse effect on the reactivity of CMC-Fe/Ni, of which the poisoning effect of sulfides (Na 2 S, Na 2 S 2 O 4 ) was significant than common ions and sulfite.

  10. Composite Ni/NiO-Cr2O3 Catalyst for Alkaline Hydrogen Evolution Reaction

    PubMed Central

    Bates, Michael K.; Jia, Qingying; Ramaswamy, Nagappan; Allen, Robert J.; Mukerjee, Sanjeev

    2015-01-01

    We report a Ni–Cr/C electrocatalyst with unprecedented mass-activity for the hydrogen evolution reaction (HER) in alkaline electrolyte. The HER kinetics of numerous binary and ternary Ni-alloys and composite Ni/metal-oxide/C samples were evaluated in aqueous 0.1 M KOH electrolyte. The highest HER mass-activity was observed for Ni–Cr materials which exhibit metallic Ni as well as NiOx and Cr2O3 phases as determined by X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) analysis. The onset of the HER is significantly improved compared to numerous binary and ternary Ni-alloys, including Ni–Mo materials. It is likely that at adjacent Ni/NiOx sites, the oxide acts as a sink for OHads, while the metallic Ni acts as a sink for the Hads intermediate of the HER, thus minimizing the high activation energy of hydrogen evolution via water reduction. This is confirmed by in situ XAS studies that show that the synergistic HER enhancement is due to NiOx content and that the Cr2O3 appears to stabilize the composite NiOx component under HER conditions (where NiOx would typically be reduced to metallic Ni0). Furthermore, in contrast to Pt, the Ni(Ox)/Cr2O3 catalyst appears resistant to poisoning by the anion exchange ionomer (AEI), a serious consideration when applied to an anionic polymer electrolyte interface. Furthermore, we report a detailed model of the double layer interface which helps explain the observed ensemble effect in the presence of AEI. PMID:26191118

  11. Fracture resistance of dental nickel-titanium rotary instruments with novel surface treatment: Thin film metallic glass coating.

    PubMed

    Chi, Chih-Wen; Deng, Yu-Lun; Lee, Jyh-Wei; Lin, Chun-Pin

    2017-05-01

    Dental nickel-titanium (NiTi) rotary instruments are widely used in endodontic therapy because they are efficient with a higher success rate. However, an unpredictable fracture of instruments may happen due to the surface characteristics of imperfection (or irregularity). This study assessed whether a novel surface treatment could increase fatigue fracture resistance of dental NiTi rotary instruments. A 200- or 500-nm thick Ti-zirconium-boron (Ti-Zr-B) thin film metallic glass was deposited on ProTaper Universal F2 files using a physical vapor deposition process. The characteristics of coating were analyzed by scanning electron microscopy, transmission electron microscopy, and X-ray diffractometry. In cyclic fatigue tests, the files were performed in a simulated root canal (radius=5 mm, angulation=60°) under a rotating speed of 300rpm. The fatigue fractured cross sections of the files were analyzed with their fractographic performances through scanning electron microscopy images. The amorphous structure of the Ti-Zr-B coating was confirmed by transmission electron microscopy and X-ray diffractometry. The surface of treated files presented smooth morphologies without grinding irregularity. For the 200- and 500-nm surface treatment groups, the coated files exhibited higher resistance of cyclic fatigue than untreated files. In fractographic analysis, treated files showed significantly larger crack-initiation zone; however, no significant differences in the areas of fatigue propagation and catastrophic fracture were found compared to untreated files. The novel surface treatment of Ti-Zr-B thin film metallic glass on dental NiTi rotary files can effectively improve the fatigue fracture resistance by offering a smooth coated surface with amorphous microstructure. Copyright © 2016. Published by Elsevier B.V.

  12. Latest status of El Niño and La Niña

    Science.gov Websites

    Simplified Chinese El Niño and La Niña Latest status (May 2018) In the past month or so, the warming trend returned to normal in April 2018, indicating that the La Niña event had come to an end. Based on the ±o, La Niña, ENSO? The impact of El Niño and La Niña on the climate of Hong Kong Seasonal and

  13. The National Socialist Sisterhood: an instrument of National Socialist health policy.

    PubMed

    Schweikardt, Christoph

    2009-06-01

    When Adolf Hitler (1889-1945) came to power in 1933, the new Nazi government focused the German health system on their priorities such as the creation of a racially homogeneous society and the preparation of war. One of the measures to bring nursing under their control was the foundation of a new sisterhood. In 1934, Erich Hilgenfeldt (1897-1945), the ambitious head of the National Socialist People's Welfare Association (Nationalsozialistische Volkswohlfahrt), founded the National Socialist (NS) Sisterhood (Nationalsozialistische Schwesternschaft) to create an elite group that would work for the goals of the National Socialist German Workers' Party (Nationalsozialistische Deutsche Arbeiterpartei, NSDAP). Hilgenfeldt proclaimed community nursing as a priority for NS Sisterhood nurses. Catholic and Protestant sisters, who were traditionally dedicated to community nursing, were to be gradually replaced. However, other competing priorities, such as hospital service for the training of junior nurses and work in conquered regions, as well as the lack of NS nursing personnel, hampered the expansion of community nursing. The paper also addresses areas for future research: everyday activities of NS nurses, the service of NS Sisterhood nurses for NSDAP organisations such as the elite racist paramilitary force SS (Schutzstaffel, Protective Squadron), and involvement in their crimes have hardly been investigated as yet.

  14. Properties of mechanically alloyed Mg-Ni-Ti ternary hydrogen storage alloys for Ni-MH batteries

    NASA Astrophysics Data System (ADS)

    Ruggeri, Stéphane; Roué, Lionel; Huot, Jacques; Schulz, Robert; Aymard, Luc; Tarascon, Jean-Marie

    MgNiTi x, Mg 1- xTi xNi and MgNi 1- xTi x (with x varying from 0 to 0.5) alloys have been prepared by high energy ball milling and tested as hydrogen storage electrodes. The initial discharge capacities of the Mg-Ni-Ti ternary alloys are inferior to the MgNi electrode capacity. However, an exception is observed with MgNi 0.95Ti 0.05, which has an initial discharge capacity of 575 mAh/g compared to 522 mAh/g for the MgNi electrode. The Mg-Ni-Ti ternary alloys show improved cycle life compared to Mg-Ni binary alloys with the same Mg/Ni atomic ratio. The best cycle life is observed with Mg 0.5Ti 0.5Ni electrode which retains 75% of initial capacity after 10 cycles in comparison to 39% for MgNi electrodes, in addition to improved high-rate dischargeability (HRD). According to the XPS analysis, the cycle life improvement of the Mg 0.5Ti 0.5Ni electrode can be related to the formation of TiO 2 which limits Mg(OH) 2 formation. The anodic polarization curve of Mg 0.5Ti 0.5Ni electrode shows that the current related to the active/passive transition is much less important and that the passive region is more extended than for the MgNi electrode but the corrosion of the electrode is still significant. This suggests that the cycle life improvement would be also associated with a decrease of the particle pulverization upon cycling.

  15. Ni-P/Zn-Ni compositionally modulated multilayer coatings - Part 2: Corrosion and protection mechanisms

    NASA Astrophysics Data System (ADS)

    Bahadormanesh, Behrouz; Ghorbani, Mohammad

    2018-06-01

    The Ni-P/Zn-Ni compositionally modulated multilayer coatings CMMCs were electrodeposited from a single bath by switching the deposition current density. The corrosion resistance of the deposits was studied and compared with that of monolayers of Ni-P and Zn-Ni alloys via Tafel polarization, EIS and salt spray tests. Characterization of corrosion products by means of EDS and XRD revealed more details from the corrosion mechanism of the monolayers and multilayers. The corrosion current density of Ni-P/Zn-Ni CMMCs were around one tenth of Zn-Ni monolayer. The CMMC with incomplete layers performed lower polarization resistance and higher corrosion current density compared to the CMMC with complete layers. The electrical circuit that was proposed for modeling the corrosion process based on the EIS spectrum, proved that layering reduces the porosity and consequently improves the barrier properties. Although, layering of Zn-Ni layers with Ni-P deposits increased the time to red rust in salt spray test, the time for white rust formation decreased. The corrosion mechanism of both Zn-Ni and Ni-P (containing small amount of Zn) was preferential dissolution of Zn and the corrosion products were comprised of mainly Zn hydroxychloride and Zn hydroxycarbonate. Also, Ni and P did not take part in the corrosion products. Based on the electrochemical character of the layers and the morphology of the corroded surface, the corrosion mechanism of multilayers was discussed.

  16. El Niño Helps Spread Bartonellosis Epidemics in Peru

    NASA Astrophysics Data System (ADS)

    Zhou, Jiayu; Lau, William K.-M.; Masuoka, Fenny M.; Andre, Richard G.; Chamberlin, Judith; Lawyer, Phillip; Laughlin, Larry W.

    The consequences of climate variability on human health, especially for poor and medically underserved populations, have received much attention in recent years. Some of the most severe health hazards induced by climate variability are epidemics of vector-borne infectious diseases. Entomologic studies have shown that insect vectors that transmit diseases, such as malaria, yellow fever, dengue, etc., are sensitive to temperature, humidity wind, and rainfall patterns, and therefore, their abundance is potentially influenced by climate variability. Because of its geographical location, the climate of tropical South America is strongly influenced by El Niño. The episodic outbreaks of various diseases in this region have been linked to the El Niño cycles. Yet, according to a report of the World Health Organization [1999], early results from South American epidemiological studies, which were based on the aggregated national disease data irrespective of the regional meteorological impacts, found no consistent correlation between the El Niño effect with the epidemics of malaria and yellow fever.

  17. SmNiO3/NdNiO3 thin film multilayers

    NASA Astrophysics Data System (ADS)

    Girardot, C.; Pignard, S.; Weiss, F.; Kreisel, J.

    2011-06-01

    Rare earth nickelates RENiO3 (RE =rare earth), which attract interest due to their sharp metal-insulator phase transition, are instable in bulk form due to the necessity of an important oxygen pressure to stabilize Ni in its 3+ state of oxidation. Here, we report the stabilization of RE nickelates in [(SmNiO3)t/(NdNiO3)t]n thin film multilayers, t being the thickness of layers alternated n times. Both bilayers and multilayers have been deposited by metal-organic chemical vapor deposition. The multilayer structure and the presence of the metastable phases SmNiO3 and NdNiO3 are evidenced from by x-ray and Raman scattering. Electric measurements of a bilayer structure further support the structural quality of the embedded RE nickelate layers.

  18. NiCo2S4 nanosheet-decorated 3D, porous Ni film@Ni wire electrode materials for all solid-state asymmetric supercapacitor applications.

    PubMed

    Saravanakumar, Balasubramaniam; Jayaseelan, Santhana Sivabalan; Seo, Min-Kang; Kim, Hak-Yong; Kim, Byoung-Suhk

    2017-12-07

    Wire type supercapacitors with high energy and power densities have generated considerable interest in wearable applications. Herein, we report a novel NiCo 2 S 4 -decorated 3D, porous Ni film@Ni wire electrode for high performance supercapacitor application. In this work, a facile method is introduced to fabricate a 3D, porous Ni film deposited on a Ni wire as a flexible electrode, followed by decoration with NiCo 2 S 4 as an electroactive material. The fabricated NiCo 2 S 4 -decorated 3D, porous Ni film@Ni wire electrode displays a superior performance with an areal and volumetric capacitance of 1.228 F cm -2 and 199.74 F cm -3 , respectively, at a current density of 0.2 mA cm -1 with a maximum volumetric energy and power density (E V : 6.935 mW h cm -3 ; P V : 1.019 W cm -3 ). Finally, the solid state asymmetric wire type supercapacitor is fabricated using the fabricated NiCo 2 S 4 -decorated 3D, porous Ni film@Ni wire as a positive electrode and N-doped reduced graphene oxide (N-rGO) as a negative electrode and this exhibits good areal and volumetric capacitances of C A : 0.12 F cm -2 and C V : 19.57 F cm -2 with a higher rate capability (92%). This asymmetric wire type supercapacitor demonstrates a low leakage current and self-discharge with a maximum volumetric energy (E V : 5.33 mW h cm -3 ) and power (P V : 855.69 mW cm -3 ) density.

  19. The acceleration intermediate phase (NiS and Ni3S2) evolution by nanocrystallization in Li/NiS2 thermal batteries with high specific capacity

    NASA Astrophysics Data System (ADS)

    Jin, Chuanyu; Zhou, Lingping; Fu, Licai; Zhu, Jiajun; Li, Deyi; Yang, Wulin

    2017-06-01

    The intermediate phase of NiS2 is thought to be a bottleneck currently to improve the overall performance of Li/NiS2 thermal batteries because of its low conductivity and close formation enthalpy between NiS2 and the intermediate phase (NiS, Ni3S2, etc). For improving the discharge performances of Li/NiS2 thermal batteries, the nano NiS2 with an average size of 85 ± 5 nm is designated as a cathode material. The electrochemical measurements show that the specific capacity of nano NiS2 cathode is higher than micro NiS2. The nano NiS2 cathode exhibits excellent electrochemical performances with high specific capacities of 794 and 654 mAh g-1 at current density of 0.1 and 0.5 A cm-2 under a cut-off voltage of 0.5 V, respectively. These results show that the rapid intermediate phase evolution from the nanocrystallization can obviously enhance use efficiency of NiS2 and improve discharge performances of thermal batteries.

  20. NiO/NiWO4 Composite Yolk-Shell Spheres with Nanoscale NiO Outer Layer for Ultrasensitive and Selective Detection of Subppm-level p-Xylene.

    PubMed

    Kim, Tae-Hyung; Kwak, Chang-Hoon; Lee, Jong-Heun

    2017-09-20

    NiO/NiWO 4 composite yolk-shell spheres with a nanoscale NiO outer layer were prepared using one-pot ultrasonic spray pyrolysis and their gas sensing characteristics were studied. The NiO/NiWO 4 yolk-shell spheres exhibited an extremely high response to 5 ppm p-xylene (ratio of resistance to gas and air = 343.5) and negligible cross-responses to 5 ppm ethanol, ammonia, carbon monoxide, hydrogen, and benzene, whereas pure NiO yolk-shell spheres showed very low responses and selectivity to all the analyte gases. The detection limit for p-xylene was as low as 22.7 ppb. This ultrasensitive and selective detection of p-xylene is attributed to a synergistic catalytic effect between NiO and NiWO 4 , high gas accessibility with large specific surface area, and increased chemiresistive variation due to the formation of a heterojunction. The NiO/NiWO 4 yolk-shell spheres with a thin NiO outer layer can be used to detect subppm-level p-xylene in a highly sensitive and selective manner for monitoring indoor air pollution.

  1. Valence electronic structure of Ni in Ni Si alloys from relative K X-ray intensity studies

    NASA Astrophysics Data System (ADS)

    Kalayci, Y.; Aydinuraz, A.; Tugluoglu, B.; Mutlu, R. H.

    2007-02-01

    The Kβ-to-Kα X-ray intensity ratio of Ni in Ni 3Si, Ni 2Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni 2Si and then increases from Ni 2Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal alloys.

  2. Silicide formation process of Pt added Ni at low temperature: Control of NiSi2 formation

    NASA Astrophysics Data System (ADS)

    Ikarashi, Nobuyuki; Masuzaki, Koji

    2011-03-01

    Transmission electron microscopy (TEM) and ab initio calculations revealed that the Ni-Si reaction around 300 °C is significantly changed by adding Pt to Ni. TEM analysis clarified that NiSi2 was formed in a reaction between Ni thin film (˜1 nm) and Si substrate, while NiSi was formed when Pt was added to the Ni film. We also found that the Ni-adamantane structure, which acts as a precursor for NiSi2 formation around the reaction temperature, was formed in the former reaction but was significantly suppressed in the latter reaction. Theoretical calculations indicated that Pt addition increased stress at the Ni-adamantane structure/Si-substrate interface. The increase in interface stress caused by Pt addition should raise the interface energy to suppress the Ni-adamantane structure formation, leading to NiSi2 formation being suppressed.

  3. Cyclic creep and fatigue of TD-NiCr (thoria-dispersion-strengthened nickel-chromium), TD-Ni, and NiCr sheet at 1200 C

    NASA Technical Reports Server (NTRS)

    Hirschberg, M. H.; Spera, D. A.; Klima, S. J.

    1972-01-01

    The resistance of thin TD-NiCr sheet to cyclic deformation was compared with that of TD-Ni and a conventional nickel-chromium alloy. Strains were determined by a calibration technique which combines room-temperature strain gage and deflection measurements with high-temperature deflection measurements. Analyses of the cyclic tests using measured tensile and creep-rupture data indicated that the TD-NiCr and NiCr alloy specimens failed by a cyclic creep mechanism. The TD-Ni specimens, on the other hand, failed by a fatigue mechanism.

  4. Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue.

    PubMed

    Ye, Jia; Gao, Yong

    2012-01-01

    Rotary instruments made of a new nickel-titanium (NiTi) alloy (M-Wire) have shown improved cyclic fatigue resistance and mechanical properties compared with those made of conventional superelastic NiTi wires. The objective of this study was to characterize microstructural changes of M-Wire throughout the cyclic fatigue process under controlled strain amplitude. The average fatigue life was calculated from 30 M-Wire samples that were subjected to a strain-controlled (≈ 4%) rotating bend fatigue test at room temperature and rotational speed of 300 rpm. Microstructural evolution of M-Wire has been investigated by different metallurgical characterization techniques, including differential scanning calorimetry, Vickers microhardness, and transmission electron microscopy at 4 different stages (as-received state, 30%, 60%, and 90% of average fatigue life). During rotating bend fatigue test, no statistically significant difference (P > .05) was found on austenite finish temperatures between as-received M-Wire and fatigued samples. However, significant differences (P < .05) were observed on Vickers microhardness for samples with 60% and 90% fatigue life compared with as-received and 30% fatigue life. Coincidentally, substantial growth of martensite grains and martensite twins was observed in microstructure under transmission electron microscopy after 60% fatigue life. The results of the present study suggested that endodontic instruments manufactured with M-Wire are expected to have higher strength and wear resistance than similar instruments made of conventional superelastic NiTi wires because of its unique nano-crystalline martensitic microstructure. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Ion irradiation induced defect evolution in Ni and Ni-based FCC equiatomic binary alloys

    DOE PAGES

    Jin, Ke; Zhang, Yanwen; Bei, Hongbin

    2015-09-09

    In order to explore the chemical effects on radiation response of alloys with multi-principal elements, defect evolution under Au ion irradiation was investigated in the elemental Ni, equiatomic NiCo and NiFe alloys. Single crystals were successfully grown in an optical floating zone furnace and their (100) surfaces were irradiated with 3 MeV Au ions at fluences ranging from 1 × 10 13 to 5 × 10 15 ions cm –2 at room temperature. The irradiation-induced defect evolution was analyzed by using ion channeling technique. Experiment shows that NiFe is more irradiation-resistant than NiCo and pure Ni at low fluences. Withmore » continuously increasing the ion fluences, damage level is eventually saturated for all materials but at different dose levels. The saturation level in pure Ni appears at relatively lower irradiation fluence than the alloys, suggesting that damage accumulation slows down in the alloys. Here, under high-fluence irradiations, pure Ni has wider damage ranges than the alloys, indicating that defects in pure Ni have high mobility.« less

  6. Modeling and Characterization of the Magnetocaloric Effect in Ni2MnGa Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nicholson, Don M; Odbadrakh, Khorgolkhuu; Rios, Orlando

    2012-01-01

    Magnetic shape memory alloys have great promise as magneto-caloric effect refrigerant materials due to their combined magnetic and structural transitions. Computational and experimental research is reported on the Ni2MnGa material system. The magnetic states of this system have been explored using the Wang-Landau statistical approach in conjunction with the Locally Self-consistent Multiple-Scattering (LSMS) method to explore the magnetic states responsible for the magnet-caloric effect in this material. The effects of alloying agents on the transition temperatures of the Ni2MnGa alloy were investigated using differential scanning calorimetry (DSC) and superconducting quantum interference device (SQUID). Neutron scattering experiments were performed to observemore » the structural and magnetic phase transformations at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) on alloys of Ni-Mn-Ga and Ni-Mn-Ga-Cu-Fe. Data from the observations are discussed in comparison with the computational studies.« less

  7. Influence of annealing temperature on the microstructure and magnetic properties of Ni/NiO core-shell nanowires

    NASA Astrophysics Data System (ADS)

    Xiang, Wenfeng; Liu, Yuan; Yao, Jiangfeng; Sun, Rui

    2018-03-01

    Ni/NiO core-shell nanowires (NWs) were synthesized by thermal annealing of Ni NWs and variations in the microstructure, surface morphology, and magnetic properties of the NWs as a function of annealing temperature were investigated. The results showed that the grain size and crystal quality of NiO increased with an increasing annealing temperature. Specially, the effect of annealing temperature was much greater than annealing time for the formation of Ni/NiO NWs during the oxidization process. The total weight gain of the Ni/NiO NWs continuously increased when the annealing temperature was lower than 400 °C and the annealing time was more than 2 h; however, the weight gain of the Ni/NiO NWs was almost constant after annealing for 40 min when the annealing temperature was higher than 500 °C. The thorns on the surface of the Ni/NiO NWs gradually passivated and magnetic properties declined when the annealing temperature was increased from 300 °C to 400 °C. Smooth Ni/NiO NWs with no magnetic properties were prepared when the annealing temperature was over 500 °C. The detail study regarding the formation and evolution of Ni/NiO NWs is of considerable value and may provide useful information regarding the choice of post-treatment parameters for different applications of Ni/NiO NWs.

  8. Tuning the porosity of mesoporous NiO through calcining isostructural Ni-MOFs toward supercapacitor applications

    NASA Astrophysics Data System (ADS)

    Hou, Xiang-Yang; Yan, Xiao-Li; Wang, Xiao; Zhai, Quan-Guo

    2018-07-01

    NiO has an unusually high theoretical specific capacitance and possess relatively high electrical conductivity compared to other metal oxides. However, the reported specific capacitance of the NiO-based electrodes is far below the theoretical value up to now. In this paper, three porous NiO materials with different specific surface area were synthesized simply by calcining iso-structural Ni-based MOFs templates. The formation mechanism of NiO was discussed by taking into account the thermal behavior and intrinsic structural features of the Ni-MOFs. Taking advantages of the Ni-MOFs precursors, all prepared NiO compounds are mesoporous and their porosity can be tuned by the structure of MOFs. Specially, due to the high porosity, three NiO exhibited an improved electrochemical performance and the specific discharge capacitances are of 102, 105, and 116 F g-1 at the current density of 1 A g-1, respectively. The specific capacitance of 1-NiO-450 is approximately 93.2% of its maximum value after 3000 cycles, which obviously superior to most of the previously reported NiO electrode materials and suggests their promising applications in supercapacitors.

  9. Ab initio molecular dynamics investigations of low-energy recoil events in Ni and NiCo

    DOE PAGES

    Liu, Bin; Yuan, Fenglin; Jin, Ke; ...

    2015-10-06

    Low-energy recoil events in pure Ni and the equiatomic NiCo alloy are studied using ab initio molecular dynamics simulations. We found that the threshold displacement energies are strongly dependent on orientation and weakly dependent on composition. The minimum threshold displacement energies are along the [1 1 0] direction in both pure Ni and the NiCo alloy. Compared to pure Ni, the threshold displacement energies increase slightly in the NiCo alloy due to stronger bonds in the alloy, irrespective of the element type of the PKA. A single Ni interstitial occupying the center of a tetrahedron formed by four Ni atomsmore » and a <1 0 0> split interstitial is produced in pure Ni by the recoils, while only the <1 0 0> split interstitial is formed in the NiCo alloy. Compared to the replacement sequences in pure Ni, anti-site defect sequences are observed in the alloy, which have high efficiency for both producing defects and transporting energy outside of the cascade core. These results provide insights into energy transfer processes occurring in equiatomic alloys under irradiation.« less

  10. Synthesis and characterization of T[Ni(CN){sub 4}].2pyz with T=Fe, Ni; pyz=pyrazine: Formation of T-pyz-Ni bridges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lemus-Santana, A.A.; Rodriguez-Hernandez, J.; Institute of Materials Science and Technology, University of Havana

    2011-08-15

    The formation of T-pyz-Ni bridges (pyz=pyrazine) in the T[Ni(CN){sub 4}].2pyz series is known for T=Mn, Zn, Cd and Co but not with T=Fe, Ni. In this contribution the existence of such bridges also for T=Fe, Ni is discussed. The obtained pillared solids, T[Ni(CN){sub 4}].2pyz, were characterized from XRD, TG, UV-Vis, IR, Raman, Moessbauer and magnetic data. Their crystal structures were refined in the orthorhombic Pmna space group from XRD powder patterns. The structural behavior of these solids on cooling down to 77 K was also studied. In the 180-200 K temperature range the occurrence of a structural transition to amore » monoclinic structure (P2{sub 1}/c space group) was observed. No temperature induced spin transition was observed for Fe[Ni(CN){sub 4}].2pyz. The iron (II) was found to be in high spin electronic state and this configuration is preserved on cooling down to 2 K. The magnetic data indicate the occurrence of a low temperature weak anti-ferromagnetic interaction between T metal centers within the T[Ni(CN){sub 4}] layer. In the paramagnetic region for Ni[Ni(CN){sub 4}].2pyz, a reversible temperature induced spin transition for the inner Ni atom was detected. - Graphical abstract: Rippled sheets structure for the pillared solids T[Ni(CN){sub 4}].2pyz. The pyrazine molecule is found forming T-pyz-Ni bridges between neighboring layers. Highlights: > Pillared 2D solids. > Inorganic-organic solids. > Assembling of molecular blocks. > From 1D and 2D building blocks to 3D solids.« less

  11. Aircraft noise measurement instrumentation and techniques

    DOT National Transportation Integrated Search

    1996-08-01

    This letter report describes aircraft noise measurement instrumentation to : be used in the field. It includes guidance on good field-measurement : practice, general rules-of-thumb, as well as references to appropriate : national and international st...

  12. Comparative study of the dissociation energies of Ni2 and Ni2(+)

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Partridge, Harry; Langhoff, Stephen R.

    1992-01-01

    Computations at the internally contracted averaged coupled-pair-functional level of theory yield a dissociation energy (Do) for Ni2(+) that is 0.17 eV larger than that of Ni2. This finding is consistent with the collision-induced dissociation experiments of Lian, Su, and Armentrout, but rules out the results from the resonant two-photon dissociation experiments of Lessen and Brucat, which predict that the Do value of Ni2(+) is about 1 eV larger than that of Ni2.

  13. Local lattice distortion in NiCoCr, FeCoNiCr and FeCoNiCrMn concentrated alloys investigated by synchrotron X-ray diffraction

    DOE PAGES

    Tong, Yang; Jin, Ke; Bei, Hongbin; ...

    2018-05-26

    Severe lattice distortion is presumptively considered as a core effect of high-entropy alloys, but quantitative measurements are still missing. Here, we demonstrate that the lattice distortion in high-entropy alloys can be quantitatively analyzed based on pair distribution function obtained from synchrotron X-ray diffraction. By applying this method to equiatomic NiCoCr, FeCoNiCr and FeCoNiCrMn concentrated alloys, we found that the local lattice distortion in the NiCoCr (0.23%) and FeCoNiCrMn (0.24%) alloys are comparable while negligible in the FeCoNiCr alloy (0.04%). Furthermore, the origin of local lattice distortion in the NiCoCr and FeCoNiCrMn concentrated alloys was discussed.

  14. Local lattice distortion in NiCoCr, FeCoNiCr and FeCoNiCrMn concentrated alloys investigated by synchrotron X-ray diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tong, Yang; Jin, Ke; Bei, Hongbin

    Severe lattice distortion is presumptively considered as a core effect of high-entropy alloys, but quantitative measurements are still missing. Here, we demonstrate that the lattice distortion in high-entropy alloys can be quantitatively analyzed based on pair distribution function obtained from synchrotron X-ray diffraction. By applying this method to equiatomic NiCoCr, FeCoNiCr and FeCoNiCrMn concentrated alloys, we found that the local lattice distortion in the NiCoCr (0.23%) and FeCoNiCrMn (0.24%) alloys are comparable while negligible in the FeCoNiCr alloy (0.04%). Furthermore, the origin of local lattice distortion in the NiCoCr and FeCoNiCrMn concentrated alloys was discussed.

  15. Stress-induced solid-state amorphization of nanocrystalline Ni and NiZr investigated by atomistic simulations

    NASA Astrophysics Data System (ADS)

    Meraj, Md.; Deng, Chuang; Pal, Snehanshu

    2018-01-01

    In this study, the feasibility of stress induced solid-state amorphization (SSA) of nanocrystalline (NC) Ni and NiZr alloys having ˜10 nm grain size has been investigated under constant tensile load (uniaxial and triaxial) via molecular dynamics simulations. In order to track the structural evaluation in both NC Ni and NiZr alloys during the SSA process, various types of analysis have been used, including simulated X-ray diffraction, centro-symmetry parameter, Voronoi cluster, common neighbor analysis, and radial distribution function. It is found that SSA in both NC Ni and NiZr alloys can only be achieved under triaxial loading conditions, and the hydrostatic tensile stress required for SSA is significantly lower when at. % Zr is increased in the NC NiZr alloy. Specifically, SSA in NC Ni and Ni-5 at. % Zr alloy was observed only when the temperature and hydrostatic tensile stress reached 800 K and 6 GPa, while SSA could occur in NC Ni-10 at. % Zr alloy under just 2 GPa of hydrostatic tensile stress at 300 K.

  16. Epidemiologic study to explore links between Ménière syndrome and migraine headache.

    PubMed

    Gopen, Quinton; Viirre, Erik; Anderson, John

    2009-11-01

    Many authors have noted an association between Ménière syndrome and migraine headache. In an attempt to explore a possible link between these two disorders, we performed an epidemiologic study. The National Health Interview Survey (NHIS) includes interviews with tens of thousands of patients annually to estimate the incidence of various diseases. In this study the data collected from the NHIS for the years 1986 to 1988 and 1994 were analyzed to determine the incidence of Ménière syndrome and migraine headache. A total of 423,400 individuals were interviewed over the combined 4 years included in this evaluation. The incidence of migraine headache was calculated at 3.8%, and the incidence of Ménière syndrome was estimated at 0.14%. The incidence of migraine headache in patients with Ménière syndrome was estimated at 4.5%. The incidence of migraine headache was not substantially elevated in patients with Ménière syndrome when compared to the general population.

  17. Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage.

    PubMed

    Mandel, E; Adib-Yazdi, M; Benhamou, L M; Lachkar, T; Mesgouez, C; Sobel, M

    1999-11-01

    The aim of this study was to determine the incidence of fracture of ProFile 0.4 and 0.6 taper Series 29 nickel-titanium instruments with respect to operator experience. A total of 125 simulated root canals in resin blocks with the same geometrical shape in terms of angle and radius of curvature and coronal and apical orifice diameter were used. Five operators prepared all the specimens using an identical step-down instrument sequence, each one preparing 25 canals. The operators included two endodontists and three general practitioners. Statistical data concerning the incidence of instrument failure was compiled using Statlab and Fisher's partial least square difference analysis of variance. A total of 21 (16.8%) instruments fractured, all had 0.04 tapers. Nine size 25 instruments failed, 9 size 20 instruments failed and 3 size 15. During the study, the Binary Tree analysis of instrument failure revealed two operator populations belonging to two different study periods. The first period, which represented the first 13 root canal preparations, was called the 'learning period', and the second period, which represented the next 12 sample preparations, was called the 'application period'. A greater number of instruments failed during the first period than during the second. In the 'learning period', both groups of operators learned the same way. In the 'application period', two groups could be distinguished; the first group consisted of a general practitioner who produced worse results, and the second group consisted of the other four operators. The results indicate the necessity of mastering this rotary canal preparation technique, and the importance of improving competence through learning and experience.

  18. Oxide Scales Formed on NiTi and NiPtTi Shape Memory Alloys

    NASA Technical Reports Server (NTRS)

    Smialek, James L.; Garg, Anita; Rogers, Richard B.; Noebe, Ronald D.

    2011-01-01

    Ni-49Ti and Ni-30Pt-50Ti (at.%) shape memory alloys were oxidized isothermally in air over the temperature range of 500 to 900 C. The microstructure, composition, and phase content of the scales were studied by SEM, EDS, XRD, and metallography. Extensive plan view SEM/EDS identified various features of intact or spalled scale surfaces. The outer surface of the scale was a relatively pure TiO2 rutile structure, typified by a distinct highly striated and faceted crystal morphology. Crystal size increased significantly with temperature. Spalled regions exhibited some porosity and less distinct features. More detailed information was obtained by correlation of SEM/EDS studies of 700 C/100 hr cross-sections with XRD analyses of serial or taper-polishing of plan surfaces. Overall, multiple layers exhibited graded mixtures of NiO, TiO2, NiTiO3, Ni(Ti) or Pt(Ni,Ti) metal dispersoids, Ni3Ti or Pt3Ti depletion zones, and substrate, in that order. The NiTi alloy contained a 3 at.% Fe impurity that appeared in embedded localized Fe-Ti-rich oxides, while the NiPtTi alloy contained a 2 v/o dispersion of TiC that appeared in lower layers. The oxidation kinetics of both alloys (in a previous report) indicated parabolic growth and an activation energy (250 kJ/mole) near those reported in other Ti and NiTi studies. This is generally consistent with TiO2 existing as the primary scale constituent, as described here.

  19. Chemical characterization of gas- and oil-bearing shales by instrumental neutron activation analysis

    USGS Publications Warehouse

    Frost, J.K.; Koszykowski, R.F.; Klemm, R.C.

    1982-01-01

    The concentration of As, Ba, Ca, Co, Cr, Cs, Dy, Eu, Fe, Ga, Hf, K, La, Lu, Mn, Mo, Na, Ni, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, Yb, and Zn were determined by instrumental neutron activation analysis in block shale samples of the New Albany Group (Devonian-Mississippian) in the in the Illinois Basin. Uranium content of the samples was as high as 75 ppm and interfered in the determination of samarium, molybdenum, barium and cerium. In the determination of selenium a correction was made for interference from tantalum. U, As, Co, Mo, Ni and Sb as well as Cu, V and pyritic sulphur which were determined by other methods, were found to correlate positively with the organic carbon content of the samples. ?? 1982 Akade??miai Kiado??.

  20. How Climate Change Affected US Impacts of the 2015-16 El Niño

    NASA Astrophysics Data System (ADS)

    Hoerling, M. P.; Quan, X. W.

    2016-12-01

    The unusually dry America Southwest winter of 2015-16 is examined in the context of El Niño driving, global ocean forcing, and human-induced climate change. The El Niño event was among the strongest of the last century, as measured by NINO3.4 sea surface temperatures (SSTs). Seasonal forecasts, guided partly by historical effects of the strong 1982-83 and 1997-98 El Niños, called for abundant rains in southern California and the America Southwest. These were seen as likely, though not certain. Yet, November-April 2016 precipitation over southern California, Arizona, and western New Mexico ranked in the lower tercile of historical data, and the prevailing multiyear drought instead intensified. We present a causal storyline for winter precipitation over the America Southwest. We first diagnose if the particular "face" of the 2015-16 El Niño caused the unexpected dryness over the America Southwest. While NINO3.4 anomalies were similar among the three El Niños, the 2015-16 event had stronger warmth over the central equatorial Pacific and less warmth in the far east Pacific. However, atmospheric models forced by central to east tropical Pacific SSTs alone reveal that such distinctions among the three strongest El Niños were of little consequence for America Southwest rainfall, each driving very wet conditions. We next diagnose impacts of global SSTs on America Southwest precipitation. Whereas little difference is found for either the 1982-83 or 1997-98 simulated impacts compared to their east Pacific forcing experiments, a much weaker wet signal occurs in 2015-16 simulations. The latter was immersed in the warmest global ocean in the instrumental record, and the unusually high SSTs of the tropical warm pools were especially important in weakening El Niño's impact on the America Southwest. To isolate effects of El Niño co-acting with climate change, historical coupled model simulations are used to construct analogues for strong El Niños at various time slices of

  1. Novel electrolyte chemistries for Mg-Ni rechargeable batteries.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Diaz, Brenda; Kane, Marie; Au, Ming

    2010-10-01

    Commercial hybrid electric vehicles (HEV) and battery electric vehicles (BEV) serve as means to reduce the nation's dependence on oil. Current electric vehicles use relatively heavy nickel metal hydride (Ni-MH) rechargeable batteries. Li-ion rechargeable batteries have been developed extensively as the replacement; however, the high cost and safety concerns are still issues to be resolved before large-scale production. In this study, we propose a new highly conductive solid polymer electrolyte for Mg-Ni high electrochemical capacity batteries. The traditional corrosive alkaline aqueous electrolyte (KOH) is replaced with a dry polymer with conductivity on the order of 10{sup -2} S/cm, as measuredmore » by impedance spectroscopy. Several potential novel polymer and polymer composite candidates are presented with the best-performing electrolyte results for full cell testing and cycling.« less

  2. Length-dependent corrosion behavior, Ni2+ release, cytocompatibility, and antibacterial ability of Ni-Ti-O nanopores anodically grown on biomedical NiTi alloy.

    PubMed

    Hang, Ruiqiang; Liu, Yanlian; Bai, Long; Zhang, Xiangyu; Huang, Xiaobo; Jia, Husheng; Tang, Bin

    2018-08-01

    In the present work, nickel-titanium-oxygen nanopores with different length (0.55-114 μm) were anodically grown on nearly equiatomic nickel-titanium (NiTi) alloy. Length-dependent corrosion behavior, nickel ion (Ni 2+ ) release, cytocompatibility, and antibacterial ability were investigated by electrochemical, analytical chemistry, and biological methods. The results show constructing nanoporous structure on the NiTi alloy improve its corrosion resistance. However, the anodized samples release more Ni 2+ than that of the bare NiTi alloy, suggesting chemical dissolution of the nanopores rather than electrochemical corrosion governs the Ni 2+ release. In addition, the Ni 2+ release amount increases with nanopore length. The anodized samples show good cytocompatibility when the nanopore length is <11 μm. Encouragingly, the length scale covers the one (1-11 μm) that the nanopores showing favorable antibacterial ability. Consequently, the nanopores with length in the range of 1-11 μm are promising as coatings of biomedical NiTi alloy for anti-infection, drug delivery, and other desirable applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Peculiarities of thermoelectric half-Heusler phase formation in Gd-Ni-Sb and Lu-Ni-Sb ternary systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romaka, V.V., E-mail: romakav@lp.edu.ua; Romaka, L.; Horyn, A.

    The phase equilibria in the Gd–Ni–Sb and Lu-Ni-Sb ternary systems were studied at 873 K by X-ray and metallographic analyses in the whole concentration range. The interaction of the elements in the Gd–Ni–Sb system results the formation of five ternary compounds at investigated temperature: Gd{sub 5}Ni{sub 2}Sb (Mo{sub 5}SiB{sub 2}-type), Gd{sub 5}NiSb{sub 2} (Yb{sub 5}Sb{sub 3}-type), GdNiSb (MgAgAs-type), Gd{sub 3}Ni{sub 6}Sb{sub 5} (Y{sub 3}Ni{sub 6}Sb{sub 5}-type), and GdNi{sub 0.72}Sb{sub 2} (HfCuSi{sub 2}-type). At investigated temperature the Lu-Ni-Sb system is characterized by formation of the LuNiSb (MgAgAs-type), Lu{sub 5}Ni{sub 2}Sb (Mo{sub 5}SiB{sub 2}-type), and Lu{sub 5}Ni{sub 0.56}Sb{sub 2.44} (Yb{sub 5}Sb{sub 3}-type)more » compounds. The disordering in the crystal structure of half-Heusler GdNiSb and LuNiSb was revealed by EPMA and studied by means of Rietveld refinement and DFT modeling. The performed electronic structure calculations are in good agreement with electrical transport property studies. - Graphical abstract: Crystal structure model and electron localization function of Lu{sub 5}Ni{sub 2}Sb. Display Omitted - Highlights: • Gd-Ni-Sb and Lu-Ni-Sb phase diagrams were constructed at 873 K. • GdNiSb and LuNiSb are characterized by disordered crystal structure. • Crystal structure optimization with DFT calculations confirmed crystal structure disorder in GdNiSb and LuNiSb.« less

  4. Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.

    PubMed

    da Frota, Matheus F; Espir, Camila G; Berbert, Fábio L C V; Marques, André A F; Sponchiado-Junior, Emílio C; Tanomaru-Filho, Mario; Garcia, Lucas F R; Bonetti-Filho, Idomeo

    2014-12-01

    As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

  5. Evaluation of an immunosuppressant side effect instrument.

    PubMed

    Winsett, Rebecca P; Arheart, Kris; Stratta, Robert J; Alloway, Rita; Wicks, Mona N; Gaber, A Osama; Hathaway, Donna K

    2004-09-01

    Clinicians continue to be compelled to evaluate the impact of immunosuppressive medication side effects on the quality of life of transplant recipients. We Were asked to develop an instrument to measure side effects in immunosuppressed transplant recipients. To construct an instrument that measures the impact and severity of side effects of immunosuppressive medications used in transplantation and to assess the reliability and validity of the newly developed instrument called the Memphis Survey. The instrument was constructed by a panel of physicians, nurses, and pharmacists with experience in treating transplant recipients. A small group of kidney transplant recipients (n= 13) provided pilot data for refining and testing the instrument. A national sample of kidney, liver, and heart transplant recipients (n = 505) provided data that were used to further develop the instrument. Factor analysis was used to determine the psychological dimensions underlying the instrument and to guide the construction of scales from the survey items. The instrument scales were then computed from the dataset of 505 transplant recipients to quantify the impact of immunosuppressant side effects on the quality of life of transplant recipients. Analyses showed the final instrument scales to be valid and reliable. Exploratory analysis suggests the need for further testing of the instrument to determine gender differences.

  6. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  7. On the Ni-Ion release rate from surfaces of binary NiTi shape memory alloys

    NASA Astrophysics Data System (ADS)

    Ševčíková, Jana; Bártková, Denisa; Goldbergová, Monika; Kuběnová, Monika; Čermák, Jiří; Frenzel, Jan; Weiser, Adam; Dlouhý, Antonín

    2018-01-01

    The study is focused on Ni-ion release rates from NiTi surfaces exposed in the cell culture media and human vascular endothelial cell (HUVEC) culture environments. The NiTi surface layers situated in the depth of 70 μm below a NiTi oxide scale are affected by interactions between the NiTi alloys and the bio-environments. The finding was proved with use of inductively coupled plasma mass spectrometry and electron microscopy experiments. As the exclusive factor controlling the Ni-ion release rates was not only thicknesses of the oxide scale, but also the passivation depth, which was two-fold larger. Our experimental data strongly suggested that some other factors, in addition to the Ni concentration in the oxide scale, admittedly hydrogen soaking deep below the oxide scale, must be taken into account in order to rationalize the concentrations of Ni-ions released into the bio-environments. The suggested role of hydrogen as the surface passivation agent is also in line with the fact that the Ni-ion release rates considerably decrease in NiTi samples that were annealed in controlled hydrogen atmospheres prior to bio-environmental exposures.

  8. Simple solution-combustion synthesis of Ni-NiO@C nanocomposites with highly electrocatalytic activity for methanol oxidation

    NASA Astrophysics Data System (ADS)

    Yu, Jie; Ni, Yonghong; Zhai, Muheng

    2018-01-01

    Transition metal and its oxide composite nanomaterials are attracting increasing research interest due to their superior properties and extensive applications in many fields. In this paper, Ni-NiO@C nanocomposites were successfully synthesized in one step via a simple solution-combustion route, employing NiCl2 as the Ni source, oxygen in the atmosphere as the oxygen source, and ethanol as the solvent. The final product was characterized by powder X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDS), (high resolution) transmission electron microscopy (TEM/HRTEM), and Raman spectra. N2 gas sorption-desorption experiments uncovered that the BET surface area of Ni-NiO@C nanocomposites reached 161.9 m2 g-1, far higher than 34.2 m2 g-1 of Ni-NiO. The electrochemical measurement showed that the as-produced Ni-NiO@C nanocomposites presented better catalytic activity for the electro-oxidation of methanol than Ni-NiO and NiO, which provides a new catalyst selection for the electro-oxidation of methanol.

  9. Quantitative assessment of apical debris extrusion and intracanal debris in the apical third, using hand instrumentation and three rotary instrumentation systems.

    PubMed

    H K, Sowmya; T S, Subhash; Goel, Beena Rani; T N, Nandini; Bhandi, Shilpa H

    2014-02-01

    Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third.

  10. Thermoelectric properties of (DyNiSn)1-x(DyNiSb)x composite

    NASA Astrophysics Data System (ADS)

    Synoradzki, Karol; Ciesielski, Kamil; Kępiński, Leszek; Kaczorowski, Dariusz

    2018-05-01

    High temperature thermoelectric properties of bulk and ball-milled cold-pressed (DyNiSn)1-x(DyNiSb)x composite materials have been studied. For bulk pure DyNiSn and DyNiSb samples the Seebeck coefficient reaches - 5.5 μV/K at 480 K and 120 μV/K at 540 K, respectively. Composite materials show metallic-like electrical resistivity and positive sign of Seebeck coefficient with values up to 50 times higher than in pure DyNiSn compound at 1000 K. Only for the sample with x = 0.47, the ball-milling drives to increase of Seebeck coefficient of about 37% at 650 K.

  11. Effects of two-temperature model on cascade evolution in Ni and NiFe

    DOE PAGES

    Samolyuk, German D.; Xue, Haizhou; Bei, Hongbin; ...

    2016-07-05

    We perform molecular dynamics simulations of Ni ion cascades in Ni and equiatomic NiFe under the following conditions: (a) classical molecular dynamics (MD) simulations without consideration of electronic energy loss, (b) classical MD simulations with the electronic stopping included, and (c) using the coupled two-temperature MD (2T-MD) model that incorporates both the electronic stopping and the electron-phonon interactions. Our results indicate that the electronic effects are more profound in the higher-energy cascades, and that the 2T-MD model results in a smaller amount of surviving damage and smaller defect clusters, while less damage is produced in NiFe than in Ni.

  12. Superconductivity in Bi/Ni bilayer system: Clear role of superconducting phases found at Bi/Ni interface

    NASA Astrophysics Data System (ADS)

    Liu, L. Y.; Xing, Y. T.; Merino, I. L. C.; Micklitz, H.; Franceschini, D. F.; Baggio-Saitovitch, E.; Bell, D. C.; Solórzano, I. G.

    2018-01-01

    Bi/Ni bilayers with varying Bi and Ni layer thicknesses have been prepared by (a) pulsed-laser deposition (PLD) at 300 K and (b) thermal evaporation at 4.2 K. A two-step superconducting transition appears on the electrical transport measurements in the samples prepared by PLD. High-resolution transmission and scanning transmission electron microscopy, supported by energy-dispersive x-ray spectroscopy (EDXS) analysis, reveal that two superconducting intermetallic alloys, namely NiBi and NiBi3, are formed by interdiffusion, if the bilayers are prepared at 300 K. The Tc of the two phases behaves very differently in an external magnetic field and the upper critical magnetic fields at zero temperature [Bc 2(0 ) ] were estimated as 1.1 and 7.4 T, respectively. The lower value corresponds to the Bc 2(0) of NiBi3 phase and the higher one is supposed to be of NiBi. These alloys are responsible for the superconductivity and the two-step transition appearing in the Bi/Ni bilayer system. Surprisingly, the Bi-rich phase (NiBi3) is formed near the Ni layer, while the Ni-rich phase (NiBi) is formed far from the Ni layer. The EDXS analysis at nanometer scale clearly shows an unusual increase of Ni concentration near the interface of Bi/substrate. The limited thickness of Bi layer in the interdiffusion process results in an unexpected distribution of Ni concentration. Samples prepared at 4.2 K after annealing at 300 K do not show any superconductivity, which indicates that a nonepitaxial Bi/Ni interface does not induce superconductivity in the case interdiffusion does not occur. These results offer a deeper understanding of the superconductivity in the Bi/Ni bilayer system.

  13. Extreme temperatures in Southeast Asia caused by El Niño and worsened by global warming

    NASA Astrophysics Data System (ADS)

    Thirumalai, Kaustubh; Dinezio, Pedro N.; Okumura, Yuko; Deser, Clara

    2017-06-01

    In April 2016, southeast Asia experienced surface air temperatures (SATs) that surpassed national records, exacerbated energy consumption, disrupted agriculture and caused severe human discomfort. Here we show using observations and an ensemble of global warming simulations the combined impact of the El Niño/Southern Oscillation (ENSO) phenomenon and long-term warming on regional SAT extremes. We find a robust relationship between ENSO and southeast Asian SATs wherein virtually all April extremes occur during El Niño years. We then quantify the relative contributions of long-term warming and the 2015-16 El Niño to the extreme April 2016 SATs. The results indicate that global warming increases the likelihood of record-breaking April extremes where we estimate that 29% of the 2016 anomaly was caused by warming and 49% by El Niño. These post-Niño Aprils can potentially be anticipated a few months in advance, and thus, help societies prepare for the projected continued increases in extremes.

  14. Extreme temperatures in Southeast Asia caused by El Niño and worsened by global warming.

    PubMed

    Thirumalai, Kaustubh; DiNezio, Pedro N; Okumura, Yuko; Deser, Clara

    2017-06-06

    In April 2016, southeast Asia experienced surface air temperatures (SATs) that surpassed national records, exacerbated energy consumption, disrupted agriculture and caused severe human discomfort. Here we show using observations and an ensemble of global warming simulations the combined impact of the El Niño/Southern Oscillation (ENSO) phenomenon and long-term warming on regional SAT extremes. We find a robust relationship between ENSO and southeast Asian SATs wherein virtually all April extremes occur during El Niño years. We then quantify the relative contributions of long-term warming and the 2015-16 El Niño to the extreme April 2016 SATs. The results indicate that global warming increases the likelihood of record-breaking April extremes where we estimate that 29% of the 2016 anomaly was caused by warming and 49% by El Niño. These post-Niño Aprils can potentially be anticipated a few months in advance, and thus, help societies prepare for the projected continued increases in extremes.

  15. Cold Spray Deposition of Ni and WC-Reinforced Ni Matrix Composite Coatings

    NASA Astrophysics Data System (ADS)

    Alidokht, S. A.; Vo, P.; Yue, S.; Chromik, R. R.

    2017-12-01

    Ni-WC composites are ideal protective coatings against wear and are often fabricated using laser cladding and thermal spray processes, but the high temperatures of these processes result in decarburization, which deteriorates the performance of the coating. Cold spray has the potential to deposit Ni-WC composite coatings and retain the composition of the initial WC feedstock. However, the insignificant plastic deformation of hard WC particles makes it difficult to build up a high WC content coating by cold spray. By using three different WC powder sizes, the effect of feedstock powder size on WC retention was tested. To improve WC retention, a WC/Ni composite powder in mixture with Ni was also sprayed. Microstructural characterization, including the deformed structure of Ni splats, retention, distribution, and fragmentation of WC, was performed by scanning electron microscopy. An improvement in WC retention was achieved using finer WC particles. Significant improvement in WC particles retention was achieved using WC/Ni composite powder, with the WC content in the coating being close to that of the feedstock.

  16. Effect of pulse frequency on microstructural, nanomechanical, and wear properties of electrodeposited Ni-TiN composite coatings

    NASA Astrophysics Data System (ADS)

    Xia, Fafeng; Tian, Jiyu; Ma, Chunyang; Potts, Matt; Guo, Xue

    2014-12-01

    The current paper reports successful syntheses of Ni-TiN composite coatings by pulse electrodeposition. The effect of pulse frequency on the microstructures, nanomechanical, and wear properties of the coatings was investigated using transmission electron microscopy, X-ray diffraction, nanoindenter, scanning electron microscopy, and wear test instrument. The results showed that the Ni-TiN composite coating prepared at the pulse frequency of 100 Hz showed the presence of a less number of TiN particles and some degrees of aggregation in micro-regions. By contrast, in the Ni-TiN coating deposited at the pulse frequency of 500 Hz, the TiN particles were large in number and dispersed homogeneously, thereby, offering the coating a uniform and fine structure. The average grain diameters of Ni and TiN in the coating prepared at 100 Hz were 154.7 and 44.8 nm, respectively, whereas those for the coating prepared at 500 Hz were 67.3 and 25.9 nm, respectively. The maximum TiN content in the Ni-TiN coating deposited at 800 Hz was approximately 10.5 wt. %. The maximum microhardness and the Young's modulus values for the Ni-TiN composite coatings deposited at 800 Hz were 35.7 GPa and 167.4 GPa, respectively. Furthermore, the Ni-TiN composite coating prepared at 100 Hz had more severe damages, whereas the morphologies of worn surface of the coatings deposited at 500 Hz and 800 Hz were smooth and only a few small pits appeared on the surface.

  17. EGSE customization for the Euclid NISP Instrument AIV/AIT activities

    NASA Astrophysics Data System (ADS)

    Franceschi, E.; Trifoglio, M.; Gianotti, F.; Conforti, V.; Andersen, J. J.; Stephen, J. B.; Valenziano, L.; Auricchio, N.; Bulgarelli, A.; De Rosa, A.; Fioretti, V.; Maiorano, E.; Morgante, G.; Nicastro, L.; Sortino, F.; Zoli, A.; Balestra, A.; Bonino, D.; Bonoli, C.; Bortoletto, F.; Capobianco, V.; Corcione, L.; Dal Corso, F.; Debei, S.; Di Ferdinando, D.; Dusini, S.; Farinelli, R.; Fornari, F.; Giacomini, F.; Guizzo, G. P.; Laudisio, F.; Ligori, S.; Mauri, N.; Medinaceli, E.; Patrizii, L.; Sirignano, C.; Sirri, G.; Stanco, L.; Tenti, M.; Valieri, C.; Ventura, S.

    2016-07-01

    The Near Infrared Spectro-Photometer (NISP) on board the Euclid ESA mission will be developed and tested at various levels of integration by using various test equipment. The Electrical Ground Support Equipment (EGSE) shall be required to support the assembly, integration, verification and testing (AIV/AIT) and calibration activities at instrument level before delivery to ESA, and at satellite level, when the NISP instrument is mounted on the spacecraft. In the case of the Euclid mission this EGSE will be provided by ESA to NISP team, in the HW/SW framework called "CCS Lite", with a possible first usage already during the Warm Electronics (WE) AIV/AIT activities. In this paper we discuss how we will customize that "CCS Lite" as required to support both the WE and Instrument test activities. This customization will primarily involve building the NISP Mission Information Base (the CCS MIB tables) by gathering the relevant data from the instrument sub-units and validating these inputs through specific tools. Secondarily, it will imply developing a suitable set of test sequences, by using uTOPE (an extension to the TCL scripting language, included in the CCS framework), in order to implement the foreseen test procedures. In addition and in parallel, custom interfaces shall be set up between the CCS and the NI-IWS (the NISP Instrument Workstation, which will be in use at any level starting from the WE activities), and also between the CCS and the TCC (the Telescope Control and command Computer, to be only and specifically used during the instrument level tests).

  18. He behavior in Ni and Ni-based equiatomic solid solution alloy

    NASA Astrophysics Data System (ADS)

    Yan, Zhanfeng; Liu, Shaoshuai; Xia, Songqin; Zhang, Yong; Wang, Yugang; Yang, Tengfei

    2018-07-01

    In the current work, pure nickel (99.99 wt.%) and Ni-containing single phase equiatomic solid solution alloy Fe-Co-Cr-Ni were irradiated with 190 keV He ions at room temperature with different fluences and He behavior in both materials are compared. At 1 × 1017 cm-2, TEM observation reveals that only isolated and small He bubbles (1-2 nm) are formed in Fe-Co-Cr-Ni alloy while many small suspected "string"-like He bubbles are observed in nickel at the concentration peak region (5.5 at.%). When the fluence is increased to 5 × 1017 cm-2, average bubble size in nickel increases to ∼8 nm which is almost equal to that in Fe-Co-Cr-Ni, but a higher bubble density is observed in nickel. At the highest dose of 1 × 1018 cm-2, numerous surface blisters and exfoliations occur in nickel which are consistent with TEM observation, while the Fe-Co-Cr-Ni alloy only shows a slight surface blister. Bubble coarsening upon annealing at 500 °C (2 h) is observed at 5 × 1017 cm-2 in both alloys, but a significant larger bubble growth is observed in nickel, suggesting a relatively better resistance to He bubble growth for Fe-Co-Cr-Ni alloy.

  19. The Effects of El Niño on Precipitation in Southern California Climate Divisions: Year 2016 Precipitation Forecast.

    NASA Astrophysics Data System (ADS)

    Perez Cruz, L.; Idris, N.; El-Askary, H. M.

    2015-12-01

    Recently, it has been reported by the National Oceanic and Atmospheric Administration (NOAA) that there is very high chance not only for El Niño to continue through Northern Hemisphere winter 2015-16, but also a remarkable chance for El Niño to last into early spring 2016. This research aims at: 1) investigating the impact of El Niño on precipitation in the Southern California Climate Divisions: Climate Division 6 South Coast Drainage, and Division 7 South Coast Desert Basin. 2) Analyzing the precipitation of Southern California region using the Empirical Mode Decomposition Method (EMD). 3) Looking at the SOI components and compare it with the precipitation components of Southern California Climate Divisions. 4) Comparing precipitation data with Niño indices: Niño 1+2, Niño 3, Nino 3.4, and Niño 4. As results, we found a significant cross correlation of 0.7 between SOI component 10 and precipitation component 10 in Climate Division 6. Furthermore, among all the Niño indices, Niño 3 region displayed the best correlation. When we compared precipitation division 7 component 9 with Niño 3 component 10, a 0.95 cross correlation value was obtained. The lowest cross correlation value of (0.33) was obtained from Climate Division 6, precipitation component 7 with Niño 4 component 7.

  20. H-Phase Precipitation and Martensitic Transformation in Ni-rich Ni-Ti-Hf and Ni-Ti-Zr High-Temperature Shape Memory Alloys

    NASA Astrophysics Data System (ADS)

    Evirgen, A.; Pons, J.; Karaman, I.; Santamarta, R.; Noebe, R. D.

    2018-03-01

    The distributions of H-phase precipitates in Ni50.3Ti29.7Hf20 and Ni50.3Ti29.7Zr20 alloys formed by aging treatments at 500 and 550 °C or slow furnace cooling and their effects on the thermal martensitic transformation have been investigated by TEM and calorimetry. The comparative study clearly reveals faster precipitate-coarsening kinetics in the NiTiZr alloy than in NiTiHf. For precipitates of a similar size of 10-20 nm in both alloys, the martensite plates in Ni50.3Ti29.7Zr20 have larger widths and span a higher number of precipitates compared with the Ni50.3Ti29.7Hf20 alloy. However, for large H-phase particles with hundreds of nm in length, no significant differences in the martensitic microstructures of both alloy systems have been observed. The martensitic transformation temperatures of Ni50.3Ti29.7Hf20 are 80-90 °C higher than those of Ni50.3Ti29.7Zr20 in the precipitate-free state and in the presence of large particles of hundreds on nm in length, but this difference is reduced to only 10-20 °C in samples with small H-phase precipitates. The changes in the transformation temperatures are consistent with the differences in the precipitate distributions between the two alloy systems observed by TEM.

  1. Transformation to Ni5Al3 in a 63.0 at. pct Ni-Al alloy

    NASA Technical Reports Server (NTRS)

    Khadkikar, P. S.; Locci, I. E.; Vedula, K.; Michal, G. M.

    1993-01-01

    Microstructures of 63 at. pct P/M Ni-Al alloys with a composition close to the stoichiometry of the Ni5Al3 phase were investigated using homogenized and quenched specimens aged at low temperatures for various times. Results of analyses of XRD data and electron microscopy observations were used for quantitative phase analysis, performed to calculate the (NiAl + Ni5Al3)/Ni5Al3 phase boundary locations. The measured lattice parameters of Ni5Al3 phase formed at 823, 873, and 923 K indicated an increase in tetragonality of the phase with increasing nickel content.

  2. Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests.

    PubMed

    Li, Uei-Ming; Lee, Bor-Shiunn; Shih, Chin-Tsai; Lan, Wan-Hong; Lin, Chun-Pin

    2002-06-01

    Endodontic instruments upon rotation are subjected to both tensile and compressive stress in curved canals. This stress is localized at the point of curvature. The purpose of this study was to evaluate the cyclic fatigue of 0.04 ProFile nickel titanium rotary instruments operating at different rotational speeds and varied distances of pecking motion in metal blocks that simulated curved canals. A total of 150 ProFile instruments were made to rotate freely in sloped metal blocks at speeds of 200, 300, or 400 rpm by a contra-angle handpiece mounted on an Instron machine. The electric motor and Instron machine were activated until the instruments were broken in two different modes, static and dynamic pecking-motion. The fractured surfaces of separated instruments were examined under a scanning electron microscope. All data obtained were analyzed by a stepwise multiple regression method using a 95% confidence interval. The results demonstrated that the time to failure significantly decreased as the angles of curvature or the rotational speeds increased. However, as pecking distances increased, the time to failure increased. This is because a longer pecking distance gives the instrument a longer time interval before it once again passes through the highest stress area. Microscopic evaluation indicated that ductile fracture was the major cyclic failure mode. To prevent breakage of a NiTi rotary instrument, appropriate rotational speeds and continuous pecking motion in the root canals are recommended.

  3. Cavitation resistance of surface composition "Steel-Ni-TiNi-TiNiZr-cBNCo", formed by High-Velocity Oxygen-Fuel spraying

    NASA Astrophysics Data System (ADS)

    Blednova, Zh. M.; Dmitrenko, D. V.; Balaev, E. U. O.

    2018-01-01

    The object of the study is a multilayered surface composition "Steel - a Multicomponent material with Shape Memory Effect - a wear-resistant layer" under conditions of cavitation effects in sea water. Multicomponent TiNi-based coatings with addition of alloying elements such as Zr in an amount up to 10% mass, allow to create a composite material with a gradient of properties at the interface of layers, which gives new properties to coatings and improves their performance significantly. The use of materials with shape memory effect (SME) as surface layers or in the composition of surface layered compositions allows to provide an effective reaction of materials to the influence of external factors and adaptation to external influences. The surface composite layer cBN-10%Co has high hardness and strength, which ensures its resistance to shock cyclic influences of collapsing caverns. The increased roughness of the surface of a solid surface composite in the form of strong columnar structures ensures the crushing of vacuum voids, redistributing their effect on the entire surface, and not concentrating them in certain zones. In addition, the gradient structure of the multilayer composite coating TiNi-Ti33Ni49Zr18-cBN-10%Co Co makes it possible to create conditions for the relaxation of stresses created by the variable impact load of cavitation caverns and the manifestation of compensating internal forces due to thermo-elastic martensitic transformations of SME materials. The cavitation resistance of the coating TiNi-Ti33Ni49Zr18-cBN-10%Co according to the criterion of mass wear is 15-20 times higher than that of the base material without coating and 10-12 times higher than that of the TiNi-TiNiZr coating. The proposed architecture of the multifunctional gradient composition, "steel-Ni-TiNi- Ti33Ni49Zr18-cBN-10%Co", each layer of which has its functional purpose, allows to increase the service life of parts operating under conditions of cavitation-fatigue loading in

  4. Electric Monopole Transition Strengths in 62Ni

    NASA Astrophysics Data System (ADS)

    Evitts, L. J.; Garnsworthy, A. B.; Kibédi, T.; Moukaddam, M.; Alshahrani, B.; Eriksen, T. K.; Holt, J. D.; Hota, S. S.; Lane, G. J.; Lee, B. Q.; McCormick, B. P.; Palalani, N.; Reed, M. W.; Stroberg, S. R.; Stuchbery, A. E.

    2016-09-01

    Excited states in 62Ni were populated with a (p, p') reaction using the 14UD Pelletron accelerator at the Australian National University. Electric monopole transition strengths, ρ2(E0), were measured through simultaneous detection of the internal conversion electrons and γ rays emitted from the de-excitation of populated states, using the Super-e spectrometer coupled with a germanium detector. The strength of the 02+ to 01+ transition has been measured to be 77-34+23 × 10-3 and agrees with previously reported values. Upper limits have been placed on the 03+ to 01+ and 03+ to 02+ transitions. The measured ρ2(E0) value of the 22+ to 21+ transition in 62Ni has been measured for the first time and found to be one of the largest ρ2(E0) values measured to date in nuclei heavier than Ca. The low-lying states of 62Ni have previously been classified as one- and two-phonon vibrational states based on level energies. The measured electric quadrupole transition strengths are consistent with this interpretation. However as electric monopole transitions are forbidden between states which differ by one phonon number, the simple harmonic quadrupole vibrational picture is not suffcient to explain the large ρ2(E0) value for the 22+ to 21+ transition.

  5. Electrodeposition of Ni and CeO₂/Ni Nanotubes for Hydrogen Evolution Reaction Electrode.

    PubMed

    Du, Xiaoqing; Yang, Yumeng; Yi, Chenxi; Chen, Yu; Cai, Chao; Zhang, Zhao

    2018-07-01

    Ni NTs and CeO2-Ni nanotubes (NTs) have been prepared by galvanostatic electrodeposition in anodic aluminum oxide (AAO) Templates. Scanning electron microscope (SEM), high resolution transmission electron microscopy (HRTEM), energy dispersive X-ray spectroscopic (EDS) and X-ray Diffraction (XRD) are used to characterize the prepared NTs. The results showed that the preparation process of CeO2-Ni NTs was accompanied by the formation of many new phases CeNix (x = 1, 2, 3.5 or 5) and preferential orientation crystal face of Ni in CeO2-Ni NTs is 〈111〉, which is different from that Ni 〈200〉 in Ni NTs. Then linear scan voltammetry (LSV) is applied to test the electrocatalytic activity for hydrogen revolution reaction (HER) of the two electrodes in 1 M NaCl aqueous solution and find that both of the two materials exhibited good performance. Finally, the kinetics analyses from the HER process showed that Tafel slope b was mainly dependent on phase composition and electric conductivity of the electrode, while j0 was mainly dependent on its real specific surface area.

  6. A scanning tunnelling microscopy study of C and N adsorption phases on the vicinal Ni(100) surfaces Ni(810) and Ni(911)

    NASA Astrophysics Data System (ADS)

    Driver, S. M.; Toomes, R. L.; Woodruff, D. P.

    2016-04-01

    The influence of N and C chemisorption on the morphology and local structure of nominal Ni(810) and Ni(911) surfaces, both vicinal to (100) but with [001] and [ 01 1 bar ] step directions, respectively, has been investigated using scanning tunnelling microscopy (STM) and low energy electron diffraction. Ni(911) undergoes substantial step bunching in the presence of both adsorbates, with the (911)/N surface showing (411) facets, whereas for Ni(810), multiple steps 2-4 layers high are more typical. STM atomic-scale images show the (2 × 2)pg 'clock' reconstruction on the (100) terraces of the (810) surfaces with both C and N, although a second c(2 × 2) structure, most readily reconciled with a 'rumpling' reconstruction, is also seen on Ni(810)/N. On Ni(911), the clock reconstruction is not seen on the (100) terraces with either adsorbate, and these images are typified by protrusions on a (1 × 1) mesh. This absence of clock reconstruction is attributed to the different constraints imposed on the lateral movements of the surface Ni atoms adjacent to the up-step edge of the terraces with a [ 01 1 bar ] step direction.

  7. Ag-nanoparticles-decorated NiO-nanoflakes grafted Ni-nanorod arrays stuck out of porous AAO as effective SERS substrates.

    PubMed

    Zhou, Qitao; Meng, Guowen; Huang, Qing; Zhu, Chuhong; Tang, Haibin; Qian, Yiwu; Chen, Bin; Chen, Bensong

    2014-02-28

    NiO-nanoflakes (NiO-NFs) grafted Ni-nanorod (Ni-NR) arrays stuck out of the porous anodic aluminum oxide (AAO) template are achieved by a combinatorial process of AAO-confined electrodeposition of Ni-NRs, selectively etching part of the AAO template to expose the Ni-NRs, wet-etching the exposed Ni-NRs in ammonia to obtain Ni(OH)2-NFs grafted onto the cone-shaped Ni-NRs, and annealing to transform Ni(OH)2-NFs in situ into NiO-NFs. By top-view sputtering, Ag-nanoparticles (Ag-NPs) are decorated on each NiO-NFs grafted Ni-NR (denoted as NiO-NFs@Ni-NR). The resultant Ag-NPs-decorated NiO-NFs@Ni-NR (denoted as Ag-NPs@NiO-NFs@Ni-NR) arrays exhibit not only strong surface-enhanced Raman scattering (SERS) activity but also reproducible SERS-signals over the whole array. It is demonstrated that the strong SERS-activity is mainly ascribed to the high density of sub-10 nm gaps (hot spots) between the neighboring Ag-NPs, the semiconducting NiO-NFs induced chemical enhancement effect, and the lightning rod effect of the cone-shaped Ni-NRs. The three-level hierarchical nanostructure arrays stuck out of the AAO template can be utilized to probe polychlorinated biphenyls (PCBs, a kind of global environmental hazard) with a concentration as low as 5 × 10(-6) M, showing promising potential in SERS-based rapid detection of organic environmental pollutants.

  8. Photoelectrochemical Water Splitting Properties of Ti-Ni-Si-O Nanostructures on Ti-Ni-Si Alloy

    PubMed Central

    Dong, Zhenbiao; Ning, Congqin

    2017-01-01

    Ti-Ni-Si-O nanostructures were successfully prepared on Ti-1Ni-5Si alloy foils via electrochemical anodization in ethylene glycol/glycerol solutions containing a small amount of water. The Ti-Ni-Si-O nanostructures were characterized by field-emission scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), and diffuse reflectance absorption spectra. Furthermore, the photoelectrochemical water splitting properties of the Ti-Ni-Si-O nanostructure films were investigated. It was found that, after anodization, three different kinds of Ti-Ni-Si-O nanostructures formed in the α-Ti phase region, Ti2Ni phase region, and Ti5Si3 phase region of the alloy surface. Both the anatase and rutile phases of Ti-Ni-Si-O oxide appeared after annealing at 500 °C for 2 h. The photocurrent density obtained from the Ti-Ni-Si-O nanostructure photoanodes was 0.45 mA/cm2 at 0 V (vs. Ag/AgCl) in 1 M KOH solution. The above findings make it feasible to further explore excellent photoelectrochemical properties of the nanostructure-modified surface of Ti-Ni-Si ternary alloys. PMID:29088083

  9. Photoelectrochemical Water Splitting Properties of Ti-Ni-Si-O Nanostructures on Ti-Ni-Si Alloy.

    PubMed

    Li, Ting; Ding, Dongyan; Dong, Zhenbiao; Ning, Congqin

    2017-10-31

    Ti-Ni-Si-O nanostructures were successfully prepared on Ti-1Ni-5Si alloy foils via electrochemical anodization in ethylene glycol/glycerol solutions containing a small amount of water. The Ti-Ni-Si-O nanostructures were characterized by field-emission scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), and diffuse reflectance absorption spectra. Furthermore, the photoelectrochemical water splitting properties of the Ti-Ni-Si-O nanostructure films were investigated. It was found that, after anodization, three different kinds of Ti-Ni-Si-O nanostructures formed in the α-Ti phase region, Ti₂Ni phase region, and Ti₅Si₃ phase region of the alloy surface. Both the anatase and rutile phases of Ti-Ni-Si-O oxide appeared after annealing at 500 °C for 2 h. The photocurrent density obtained from the Ti-Ni-Si-O nanostructure photoanodes was 0.45 mA/cm² at 0 V (vs. Ag/AgCl) in 1 M KOH solution. The above findings make it feasible to further explore excellent photoelectrochemical properties of the nanostructure-modified surface of Ti-Ni-Si ternary alloys.

  10. Nimbus-F to carry advanced weather instruments

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Meteorological research instruments launched aboard NASA's Nimbus-F spacecraft are briefly described along with the Nimbus satellite program initiated to develop an observatory system capable of meeting the research and development needs of the nation's atmospheric and earth sciences program. The following aspects of the mission are described: spacecraft design, launch operations, sequence of orbital events, and operations control and tracking. The Global Atmospheric Research program is discussed in terms of the Nimbus-F experiments and atmospheric sounding instruments.

  11. Adios El Niño, Hello La Niña?

    NASA Image and Video Library

    2010-06-22

    This image from NASA European Ocean Surface Topography Mission/Jason-2 shows that the moderate El Niño of the past year has officially bowed out, leaving his cool sibling, La Niña, poised to potentially take the equatorial stage.

  12. Impact of Interstitial Ni on the Thermoelectric Properties of the Half-Heusler TiNiSn.

    PubMed

    Barczak, Sonia A; Buckman, Jim; Smith, Ronald I; Baker, Annabelle R; Don, Eric; Forbes, Ian; Bos, Jan-Willem G

    2018-03-30

    TiNiSn is an intensively studied half-Heusler alloy that shows great potential for waste heat recovery. Here, we report on the structures and thermoelectric properties of a series of metal-rich TiNi 1+y Sn compositions prepared via solid-state reactions and hot pressing. A general relation between the amount of interstitial Ni and lattice parameter is determined from neutron powder diffraction. High-resolution synchrotron X-ray powder diffraction reveals the occurrence of strain broadening upon hot pressing, which is attributed to the metastable arrangement of interstitial Ni. Hall measurements confirm that interstitial Ni causes weak n-type doping and a reduction in carrier mobility, which limits the power factor to 2.5-3 mW m -1 K -2 for these samples. The thermal conductivity was modelled within the Callaway approximation and is quantitively linked to the amount of interstitial Ni, resulting in a predicted value of 12.7 W m -1 K -1 at 323 K for stoichiometric TiNiSn. Interstitial Ni leads to a reduction of the thermal band gap and moves the peak ZT = 0.4 to lower temperatures, thus offering the possibility to engineer a broad ZT plateau. This work adds further insight into the impact of small amounts of interstitial Ni on the thermal and electrical transport of TiNiSn.

  13. Impact of Interstitial Ni on the Thermoelectric Properties of the Half-Heusler TiNiSn

    PubMed Central

    Barczak, Sonia A.; Smith, Ronald I.; Baker, Annabelle R.; Don, Eric; Forbes, Ian

    2018-01-01

    TiNiSn is an intensively studied half-Heusler alloy that shows great potential for waste heat recovery. Here, we report on the structures and thermoelectric properties of a series of metal-rich TiNi1+ySn compositions prepared via solid-state reactions and hot pressing. A general relation between the amount of interstitial Ni and lattice parameter is determined from neutron powder diffraction. High-resolution synchrotron X-ray powder diffraction reveals the occurrence of strain broadening upon hot pressing, which is attributed to the metastable arrangement of interstitial Ni. Hall measurements confirm that interstitial Ni causes weak n-type doping and a reduction in carrier mobility, which limits the power factor to 2.5–3 mW m−1 K−2 for these samples. The thermal conductivity was modelled within the Callaway approximation and is quantitively linked to the amount of interstitial Ni, resulting in a predicted value of 12.7 W m−1 K−1 at 323 K for stoichiometric TiNiSn. Interstitial Ni leads to a reduction of the thermal band gap and moves the peak ZT = 0.4 to lower temperatures, thus offering the possibility to engineer a broad ZT plateau. This work adds further insight into the impact of small amounts of interstitial Ni on the thermal and electrical transport of TiNiSn. PMID:29601547

  14. Crystallography of the NiHfSi Phase in a NiAl (0.5 Hf) Single-Crystal Alloy

    NASA Technical Reports Server (NTRS)

    Garg, A.; Noebe, R. D.; Darolia, R.

    1996-01-01

    Small additions of Hf to conventionally processed NiAl single crystals result in the precipitation of a high density of cuboidal G-phase along with a newly identified silicide phase. Both of these phases form in the presence of Si which is not an intentional alloying addition but is a contaminant resulting from contact with the ceramic shell molds during directional solidification of the single-crystal ingots. The morphology, crystal structure and Orientation Relationship (OR) of the silicide phase in a NiAl (0.5 at.%Hf) single-crystal alloy have been determined using transmission electron microscopy, electron microdiffraction and energy dispersive X-ray spectroscopy. Qualitative elemental analysis and indexing of the electron microdiffraction patterns from the new phase indicate that it is an orthorhombic NiHfSi phase with unit cell parameters, a = 0.639 nm, b = 0.389 nm and c = 0.72 nm, and space group Pnma. The NiHfSi phase forms as thin rectangular plates on NiAl/111/ planes with an OR that is given by NiHfSi(100))(parallel) NiAl(111) and NiHfSi zone axes(010) (parallel) NiAl zone axes (101). Twelve variants of the NiHfSi phase were observed in the alloy and the number of variants and rectangular morphology of NiHfSi plates are consistent with symmetry requirements. Quenching experiments indicate that nucleation of the NiHfSi phase in NiAI(Hf) alloys is aided by the formation of NiAl group of zone axes (111) vacancy loops that form on the NiAl /111/ planes.

  15. Control of the transition between Ni-C and Ni-SI(a) states by the redox state of the proximal Fe-S cluster in the catalytic cycle of [NiFe] hydrogenase.

    PubMed

    Tai, Hulin; Nishikawa, Koji; Suzuki, Masayuki; Higuchi, Yoshiki; Hirota, Shun

    2014-12-08

    [NiFe] hydrogenase catalyzes the reversible cleavage of H2. The electrons produced by the H2 cleavage pass through three Fe-S clusters in [NiFe] hydrogenase to its redox partner. It has been reported that the Ni-SI(a), Ni-C, and Ni-R states of [NiFe] hydrogenase are involved in the catalytic cycle, although the mechanism and regulation of the transition between the Ni-C and Ni-SI(a) states remain unrevealed. In this study, the FT-IR spectra under light irradiation at 138-198 K show that the Ni-L state of [NiFe] hydrogenase is an intermediate between the transition of the Ni-C and Ni-SI(a) states. The transition of the Ni-C state to the Ni-SI(a) state occurred when the proximal [Fe4S4]p(2+/+) cluster was oxidized, but not when it was reduced. These results show that the catalytic cycle of [NiFe] hydrogenase is controlled by the redox state of its [Fe4S4]p(2+/+) cluster, which may function as a gate for the electron flow from the NiFe active site to the redox partner. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Ni-P/Zn-Ni compositionally modulated multilayer coatings - Part 1: Electrodeposition and growth mechanism, composition, morphology, roughness and structure

    NASA Astrophysics Data System (ADS)

    Bahadormanesh, Behrouz; Ghorbani, Mohammad

    2018-06-01

    The Ni-P/Zn-Ni compositionally modulated multilayer coatings CMMCs were electrodeposited from a single bath by switching the cathodic current density. The composition, surface morphology, roughness, layers growth pattern as well as the phase structure of deposits were extensively studied via SEM, EDS, AFM and XRD analysis. Effects of bath ingredients on the electrodeposition behavior were analyzed through cathodic linear sweep voltammetry. Although the concentration of Zn2+ in bath was 13 times higher than Ni2+, the Zn-Ni deposition potential was much nearer to Ni deposition potential rather than that of Zn. Addition of NaH2PO2 to the Ni deposition bath considerably raised the current density and shifted the crystallization potential of Ni to more nobble values. Codeposition of P with Zn-Ni alloy lead to crack formation in the monolayer that was deposited in 60 mA/cm2. However, the cracks were not observed in the Zn-Ni layers of multilayers. Zn-Ni layers in CMMCs exhibited a three-dimensional pattern of growth while that of Ni-P layers was two-dimensional. Also, the Ni-P deposits tends to fill the discontinuities in Zn-Ni layers and performed leveling properties and lowered the surface roughness of Zn-Ni layers and CMMCs. Structural analysis demonstrated that Ni-P layers were amorphous and the Zn-Ni layers exhibited crystallite phase of Zn11Ni2. Thus, the Ni-P/Zn-Ni CMMCs comprised of alternate layers of amorphous Ni-P and nanocrystalline Zn Ni.

  17. Discrimination and quantification of Fe and Ni abundances in Genesis solar wind implanted collectors using X-ray standing wave fluorescence yield depth profiling with internal referencing

    DOE PAGES

    Choi, Y.; Eng, P.; Stubbs, J.; ...

    2016-08-21

    In this paper, X-ray standing wave fluorescence yield depth profiling was used to determine the solar wind implanted Fe and Ni fluences in a silicon-on-sapphire (SoS) Genesis collector (60326). An internal reference standardization method was developed based on fluorescence from Si and Al in the collector materials. Measured Fe fluence agreed well with that measured previously by us on a sapphire collector (50722) as well as SIMS results by Jurewicz et al. Measured Ni fluence was higher than expected by a factor of two; neither instrumental errors nor solar wind fractionation effects are considered significant perturbations to this value. Impuritymore » Ni within the epitaxial Si layer, if present, could explain the high Ni fluences and therefore needs further investigation. As they stand, these results are consistent with minor temporally-variable Fe and Ni fractionation on the timescale of a year.« less

  18. Discrimination and quantification of Fe and Ni abundances in Genesis solar wind implanted collectors using X-ray standing wave fluorescence yield depth profiling with internal referencing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Y.; Eng, P.; Stubbs, J.

    In this paper, X-ray standing wave fluorescence yield depth profiling was used to determine the solar wind implanted Fe and Ni fluences in a silicon-on-sapphire (SoS) Genesis collector (60326). An internal reference standardization method was developed based on fluorescence from Si and Al in the collector materials. Measured Fe fluence agreed well with that measured previously by us on a sapphire collector (50722) as well as SIMS results by Jurewicz et al. Measured Ni fluence was higher than expected by a factor of two; neither instrumental errors nor solar wind fractionation effects are considered significant perturbations to this value. Impuritymore » Ni within the epitaxial Si layer, if present, could explain the high Ni fluences and therefore needs further investigation. As they stand, these results are consistent with minor temporally-variable Fe and Ni fractionation on the timescale of a year.« less

  19. Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes

    NASA Astrophysics Data System (ADS)

    Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.; Barnett, Scott A.; Wang, Jun

    2016-02-01

    The coarsening of Ni in Ni-yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors. Here, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. The finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.

  20. Effect of Ni Core Structure on the Electrocatalytic Activity of Pt-Ni/C in Methanol Oxidation

    PubMed Central

    Kang, Jian; Wang, Rongfang; Wang, Hui; Liao, Shijun; Key, Julian; Linkov, Vladimir; Ji, Shan

    2013-01-01

    Methanol oxidation catalysts comprising an outer Pt-shell with an inner Ni-core supported on carbon, (Pt-Ni/C), were prepared with either crystalline or amorphous Ni core structures. Structural comparisons of the two forms of catalyst were made using transmission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), and methanol oxidation activity compared using CV and chronoamperometry (CA). While both the amorphous Ni core and crystalline Ni core structures were covered by similar Pt shell thickness and structure, the Pt-Ni(amorphous)/C catalyst had higher methanol oxidation activity. The amorphous Ni core thus offers improved Pt usage efficiency in direct methanol fuel cells. PMID:28811402

  1. Photosensitivity of the Ni-A state of [NiFe] hydrogenase from Desulfovibrio vulgaris Miyazaki F with visible light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osuka, Hisao; Graduate School of Materials Science, Nara Institute of Science and Technology, 8916-5, Takayama-cho, Ikoma-shi, Nara 630-0192; Shomura, Yasuhito

    2013-01-04

    Highlights: Black-Right-Pointing-Pointer Ni-A state of [NiFe] hydrogenase showed light sensitivity. Black-Right-Pointing-Pointer New FT-IR bands were observed with light irradiation of the Ni-A state. Black-Right-Pointing-Pointer EPR g-values of the Ni-A state shifted upon light irradiation. Black-Right-Pointing-Pointer The light-induced state converted back to the Ni-A state under the dark condition. -- Abstract: [NiFe] hydrogenase catalyzes reversible oxidation of molecular hydrogen. Its active site is constructed of a hetero dinuclear Ni-Fe complex, and the oxidation state of the Ni ion changes according to the redox state of the enzyme. We found that the Ni-A state (an inactive unready, oxidized state) of [NiFe] hydrogenasemore » from Desulfovibrio vulgaris Miyazaki F (DvMF) is light sensitive and forms a new state (Ni-AL) with irradiation of visible light. The Fourier transform infrared (FT-IR) bands at 1956, 2084 and 2094 cm{sup -1} of the Ni-A state shifted to 1971, 2086 and 2098 cm{sup -1} in the Ni-AL state. The g-values of g{sub x} = 2.30, g{sub y} = 2.23 and g{sub z} = 2.01 for the signals in the electron paramagnetic resonance (EPR) spectrum of the Ni-A state at room temperature varied for -0.009, +0.012 and +0.010, respectively, upon light irradiation. The light-induced Ni-AL state converted back immediately to the Ni-A state under dark condition at room temperature. These results show that the coordination structure of the Fe site of the Ni-A state of [NiFe] hydrogenase is perturbed significantly by light irradiation with relatively small coordination change at the Ni site.« less

  2. An analytical mechanical model to describe the response of NiTi rotary endodontic files in a curved root canal.

    PubMed

    Leroy, Agnès Marie Françoise; Bahia, Maria Guiomar de Azevedo; Ehrlacher, Alain; Buono, Vicente Tadeu Lopes

    2012-08-01

    To build a mathematical model describing the mechanical behavior of NiTi rotary files while they are rotating in a root canal. The file was seen as a beam undergoing large transformations. The instrument was assumed to be rotating steadily in the root canal, and the geometry of the canal was considered as a known parameter of the problem. The formulae of large transformations mechanics then allowed the calculation of the Green-Lagrange strain field in the file. The non-linear mechanical behavior of NiTi was modeled as a continuous piecewise linear function, assuming that the material did not reach plastic deformation. Criteria locating the changes of behavior of NiTi were established and the tension field in the file, and the external efforts applied on it were calculated. The unknown variable of torsion was deduced from the equilibrium equation system using a Coulomb contact law which solved the problem on a cycle of rotation. In order to verify that the model described well reality, three-point bending experiments were managed on superelastic NiTi wires, whose results were compared to the theoretical ones. It appeared that the model gave a good mentoring of the empirical results in the range of bending angles that interested us. Knowing the geometry of the root canal, one is now able to write the equations of the strain and stress fields in the endodontic instrument, and to quantify the impact of each macroscopic parameter of the problem on its response. This should be useful to predict failure of the files under rotating bending fatigue, and to optimize the geometry of the files. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Effect of NiO spin orientation on the magnetic anisotropy of the Fe film in epitaxially grown Fe/NiO/Ag(001) and Fe/NiO/MgO(001)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, W.; Jin, E.; Wu, J.

    Single crystalline Fe/NiO bilayers were epitaxially grown on Ag(001) and on MgO(001), and investigated by Low Energy Electron Diffraction (LEED), Magneto-Optic Kerr Effect (MOKE), and X-ray Magnetic Linear Dichroism (XMLD). We find that while the Fe film has an in-plane magnetization in both Fe/NiO/Ag(001) and Fe/NiO/MgO(001) systems, the NiO spin orientation changes from in-plane direction in Fe/NiO/Ag(001) to out-of-plane direction in Fe/NiO/MgO(001). These two different NiO spin orientations generate remarkable different effects that the NiO induced magnetic anisotropy in the Fe film is much greater in Fe/NiO/Ag(001) than in Fe/NiO/MgO(001). XMLD measurement shows that the much greater magnetic anisotropy inmore » Fe/NiO/Ag(001) is due to a 90{sup o}-coupling between the in-plane NiO spins and the in-plane Fe spins.« less

  4. Flexible bottom-emitting white organic light-emitting diodes with semitransparent Ni/Ag/Ni anode.

    PubMed

    Koo, Ja-Ryong; Lee, Seok Jae; Lee, Ho Won; Lee, Dong Hyung; Yang, Hyung Jin; Kim, Woo Young; Kim, Young Kwan

    2013-05-06

    We fabricated a flexible bottom-emitting white organic light-emitting diode (BEWOLED) with a structure of PET/Ni/Ag/Ni (3/6/3 nm)/ NPB (50 nm)/mCP (10 nm)/7% FIrpic:mCP (10 nm)/3% Ir(pq)(2) acac:TPBi (5 nm)/7% FIrpic:TPBi (5 nm)/TPBi (10 nm)/Liq (2 nm)/ Al (100 nm). To improve the performance of the BEWOLED, a multilayered metal stack anode of Ni/Ag/Ni treated with oxygen plasma for 60 sec was introduced into the OLED devices. The Ni/Ag/Ni anode effectively enhanced the probability of hole-electron recombination due to an efficient hole injection into and charge balance in an emitting layer. By comparing with a reference WOLED using ITO on glass, it is verified that the flexible BEWOLED showed a similar or better electroluminescence (EL) performance.

  5. Cooling field and ion-beam bombardment effects on exchange bias behavior in NiFe/(Ni,Fe)O bilayers.

    PubMed

    Lin, K W; Wei, M R; Guo, J Y

    2009-03-01

    The dependence of the cooling field and the ion-beam bombardment on the exchange bias effects in NiFe/(Ni,Fe)O bilayers were investigated. The positive exchange bias was found in the zero-field-cooled (ZFC) process whereas a negative exchange bias occurred in the FC process. The increased exchange field, H(ex) with increasing (Ni,Fe)O thicknesses indicates the thicker the AF (Ni,Fe)O, the stronger the exchange coupling between the NiFe layer and the (Ni,Fe)O layer. In addition, the dependence of the H(ex) (ZFC vs. FC) on the (Ni,Fe)O thicknesses reflects the competition between the applied magnetic field and the (Ni,Fe)O surface layer exchange coupled to the NiFe layer. Further, an unusual oscillating exchange bias was observed in NiFe/(Ni,Fe)O bilayers that results from the surface of the (Ni,Fe)O layer being bombarded with different Ar-ion energies using End-Hall deposition voltages (V(EH)) from 0 to 150 V. The behavior of the H(ex) and the H(c) with the V(EH) is attributed to the surface spin reorientation that is due to moderate ion-beam bombardment effects on the surface of the (Ni,Fe)O layer. Whether the (Ni,Fe)O antiferromagnetic spins are coupled to the NiFe moments antiferromagnetically or ferromagnetically changes the sign of the exchange bias.

  6. Corrosive sliding wear behavior of laser clad Mo 2Ni 3Si/NiSi intermetallic coating

    NASA Astrophysics Data System (ADS)

    Lu, X. D.; Wang, H. M.

    2005-05-01

    Many ternary metal silicides such as W 2Ni 3Si, Ti 2Ni 3Si and Mo 2Ni 3Si with the topologically closed-packed (TCP) hP12 MgZn 2 type Laves phase crystal structure are expected to have outstanding wear and corrosion resistance due to their inherent high hardness and sluggish temperature dependence and strong atomic bonds. In this paper, Mo 2Ni 3Si/NiSi intermetallic coating was fabricated on substrate of an austenitic stainless steel AISI321 by laser cladding using Ni-Mo-Si elemental alloy powders. Microstructure of the coating was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD) and energy dispersive X-ray analysis (EDS). Wear resistance of the coating is evaluated under corrosive sliding wear test condition. Influence of corrosion solutions on the wear resistance of the coating was studied and the wear mechanism was discussed based on observations of worn surface morphology. Results showed that the laser clad Mo 2Ni 3Si/NiSi composite coating have a fine microstructure of Mo 2Ni 3Si primary dendrites and the interdendritic Mo 2Ni 3Si/NiSi eutectics. The coating has excellent corrosive wear resistance compared with austenitic stainless steel AISI321 under acid, alkaline and saline corrosive environments.

  7. Literature Review of Multicultural Instrumentation

    ERIC Educational Resources Information Center

    Sarraj, Huda; Carter, Stacy; Burley, Hansel

    2015-01-01

    Demographic changes at the national level emphasize a critical need for multicultural education to be included as part of undergraduate education. This critical review of the literature examines 10 multicultural instruments that are suitable for use in K-12 or higher education institutions. This is a novel literature review in that it is the first…

  8. 32 CFR 37.110 - What type of instruments are technology investment agreements (TIAs)?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false What type of instruments are technology... SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS TECHNOLOGY INVESTMENT AGREEMENTS General § 37.110 What type of instruments are technology investment agreements (TIAs)? TIAs are assistance instruments...

  9. Nickel distribution and isotopic fractionation in a Brazilian lateritic regolith: Coupling Ni isotopes and Ni K-edge XANES

    NASA Astrophysics Data System (ADS)

    Ratié, G.; Garnier, J.; Calmels, D.; Vantelon, D.; Guimarães, E.; Monvoisin, G.; Nouet, J.; Ponzevera, E.; Quantin, C.

    2018-06-01

    Ultramafic (UM) rocks are known to be nickel (Ni) rich and to weather quickly, which makes them a good candidate to look at the Ni isotope systematics during weathering processes at the Earth's surface. The present study aims at identifying the Ni solid speciation and discussing the weathering processes that produce Ni isotope fractionation in two deep laterite profiles under tropical conditions (Barro Alto, Goiás State, Brazil). While phyllosilicates and to a lower extent goethite are the main Ni-bearing phases in the saprolitic part of the profile, iron (Fe) oxides dominate the Ni budget in the lateritic unit. Nickel isotopic composition (δ60Ni values) has been measured in each unit of the regolith, i.e., rock, saprock, saprolite and laterite (n = 52). δ60Ni varies widely within the two laterite profiles, from -0.10 ± 0.05‰ to 1.43 ± 0.05‰, showing that significant Ni isotope fractionation occurs during the weathering of UM rocks. Overall, our results show that during weathering, the solid phase is depleted in heavy Ni isotopes due to the preferential sorption and incorporation of light Ni isotopes into Fe oxides; the same mechanisms likely apply to the incorporation of Ni into phyllosilicates (type 2:1). However, an isotopically heavy Ni pool is observed in the solid phase at the bottom of the saprolitic unit. This feature can be explained by two hypotheses that are not mutually exclusive: (i) a depletion in light Ni isotopes during the first stage of weathering due to the preferential dissolution of light Ni-containing minerals, and (ii) the sorption or incorporation of isotopically heavy Ni carried by percolating waters (groundwater samples have δ60Ni of 2.20 and 2.27‰), that were enriched in heavy Ni isotopes due to successive weathering processes in the overlying soil and laterite units.

  10. Role of Ni-tolerant Bacillus spp. and Althea rosea L. in the phytoremediation of Ni-contaminated soils.

    PubMed

    Khan, Waheed Ullah; Yasin, Nasim Ahmad; Ahmad, Sajid Rashid; Ali, Aamir; Ahmed, Shakil; Ahmad, Aqeel

    2017-05-04

    In our current study, four nickel-tolerant (Ni-tolerant) bacterial species viz, Bacillus thuringiensis 002, Bacillus fortis 162, Bacillus subtilis 174, and Bacillus farraginis 354, were screened using Ni-contaminated media. The screened microbes exhibited positive results for synthesis of indole acetic acid (IAA), siderophore production, and phosphate solubilization. The effects of these screened microbes on Ni mobility in the soil, root elongation, plant biomass, and Ni uptake in Althea rosea plants grown in Ni-contaminated soil (200 mg Ni kg -1 ) were evaluated. Significantly higher value for water-extractable Ni (38 mg kg -1 ) was observed in case of Ni-amended soils inoculated with B. subtilis 174. Similarly, B. thuringiensis 002, B. fortis 162, and B. subtilis 174 significantly enhanced growth and Ni uptake in A. rosea. The Ni uptake in the shoots and roots of B. subtilis 174-inoculated plants enhanced up to 1.7 and 1.6-fold, respectively, as compared to that in the un-inoculated control. Bacterial inoculation also significantly improved the root and shoot biomass of treated plants. The current study presents a novel approach for bacteria-assisted phytoremediation of Ni-contaminated areas.

  11. Sputtering Yields of Si and Ni from the Ni1-xSix System Studied by Rutherford Backscattering Spectrometry

    NASA Astrophysics Data System (ADS)

    Kim, Su Chol; Yamaguchi, Satoru; Kataoka, Yoshihide; Iwami, Motohiro; Hiraki, Akio; Satou, Mamoru; Fujimoto, Fuminori

    1982-01-01

    Sputtering yields of Si and Ni from thin layer films of Ni-Si compounds (Ni1-xSix), including the pure materials (Ni and Si), caused by 5 keV Ar+ ion bombardment were investigated using backscattering spectrometry. The sputtering yield for Si from Ni1-xSix increased with increasing Si concentration. However, there is an abrupt decrease in the yield for Si concentrations above NiSi2 to pure Si. This is in clear contrast to the sputtering yield of Ni from Ni1-xSix which increased with increasing Ni concentration monotonously. These results are discussed on the basis of both the difference in the atomic density and the electronic state of the alloy.

  12. Influence of Ni on Martensitic Phase Transformations in NiTi Shape Memory Alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frenzel, J.; George, Easo P; Dlouhy, A.

    High-precision data on phase transformation temperatures in NiTi, including numerical expressions for the effect of Ni on M{sub S}, M{sub F}, A{sub S}, A{sub F} and T{sub 0}, are obtained, and the reasons for the large experimental scatter observed in previous studies are discussed. Clear experimental evidence is provided confirming the predictions of Tang et al. 1999 regarding deviations from a linear relation between the thermodynamic equilibrium temperature and Ni concentration. In addition to affecting the phase transition temperatures, increasing Ni contents are found to decrease the width of thermal hysteresis and the heat of transformation. These findings are rationalizedmore » on the basis of the crystallographic data of Prokoshkin et al. 2004 and the theory of Ball and James. The results show that it is important to document carefully the details of the arc-melting procedure used to make shape memory alloys and that, if the effects of processing are properly accounted for, precise values for the Ni concentration of the NiTi matrix can be obtained.« less

  13. Effect of cryogenic treatment on nickel-titanium endodontic instruments

    PubMed Central

    Kim, J. W.; Griggs, J. A.; Regan, J. D.; Ellis, R. A.; Cai, Z.

    2005-01-01

    Aim To investigate the effects of cryogenic treatment on nickel-titanium endodontic instruments. The null hypothesis was that cryogenic treatment would result in no changes in composition, microhardness or cutting efficiency of nickel-titanium instruments. Methodology Microhardness was measured on 30 nickel-titanium K-files (ISO size 25) using a Vicker’s indenter. Elemental composition was measured on two instruments using X-ray spectroscopy. A nickel-titanium bulk specimen was analysed for crystalline phase composition using X-ray diffraction. Half of the specimens to be used for each analysis were subjected to a cryogenic treatment in liquid nitrogen (−196 °C) for either 3 s (microhardness specimens) or 10 min (other specimens). Cutting efficiency was assessed by recording operator choice using 80 nickel-titanium rotary instruments (ProFile® 20, .06) half of which had been cryogenically treated and had been distributed amongst 14 clinicians. After conditioning by preparing four corresponding canals, each pair of instruments were evaluated for cutting efficiency by a clinician during preparation of one canal system in vitro. A Student’s t-test was used to analyse the microhardness data, and a binomial test was used to analyse the observer choice data. Composition data were analysed qualitatively. Results Cryogenically treated specimens had a significantly higher microhardness than the controls (P < 0.001; β > 0.999). Observers showed a preference for cryogenically treated instruments (61%), but this was not significant (P = 0.21). Both treated and control specimens were composed of 56% Ni, 44% Ti, 0% N (by weight) with a majority in the austenite phase. Conclusions Cryogenic treatment resulted in increased microhardness, but this increase was not detected clinically. There was no measurable change in elemental or crystalline phase composition. PMID:15910471

  14. Behavior of nickel-titanium instruments manufactured with different thermal treatments.

    PubMed

    Pereira, Érika Sales Joviano; Viana, Ana Cecília Diniz; Buono, Vicente Tadeu Lopes; Peters, Ove A; Bahia, Maria Guiomar de Azevedo

    2015-01-01

    The purpose of this study was to investigate if nickel-titanium instruments with similar designs manufactured by different thermal treatments would exhibit significantly different in vitro behavior. Thirty-six instruments each of ProTaper Universal (PTU F1; Dentsply Maillefer, Ballaigues, Switzerland), ProFile Vortex (PV; Dentsply Tulsa Dental Specialties, Tulsa, OK), Vortex Blue (VB, Dentsply Tulsa Dental Specialties), and TYPHOON Infinite Flex NiTi (TYP; Clinician's Choice Dental Products, New Milford, CT) (all size 25/.06) were evaluated. Bending resistance, torsion at failure, and dynamic torsional tests were performed with the instruments (n = 12). Analysis of variance and Tukey post hoc tests were applied. Flexibility was significantly higher for TYP compared with the other 3 groups (P < .0001). With respect to the maximum torque at failure, PV group showed the highest resistance to twisting (torsional strength) among the analyzed instruments followed by VB, TYP, and PTU. The TYP group exhibited greater angular deflection at failure compared with the other groups (P < .0001). The mean dynamic torque scores during simulated canal preparation were highest for TYP (3.01 ± 0.71 Ncm) and lowest for PV (1.62 ± 0.79 Ncm). However, no significant differences were observed comparing groups PTU with TYP and VB and VB with PV (P > .05). The highest mean forces were recorded with PTU (7.02 ± 2.36 N) and the lowest with TYP (1.22 ± 0.40 N). TYP instruments were significantly more flexible than the other instruments tested. The PV group had the highest torsional strength and TYP, despite being the most flexible, showed similar torsional moments to the other instruments, whereas its angular deflection was the highest among the groups. Copyright © 2015 American Association of Endodontists. All rights reserved.

  15. Microstructure and wear properties of laser clad Ti2Ni3Si/Ni3Ti multiphase intermetallic coatings

    NASA Astrophysics Data System (ADS)

    Wang, H. M.; Tang, H. B.; Cai, L. X.; Cao, F.; Zhang, L. Y.; Yu, R. L.

    2005-05-01

    Wear resistant Ti2Ni3Si/Ni3Ti multiphase intermetallic coatings with a microstructure consisting of Ti2Ni3Si primary dendrites and interdendritic Ti2Ni3Si/Ni3Ti eutectic were fabricated on a substrate of 0.2% C plain carbon steel by a laser cladding process with Ti-Ni-Si alloy powders. The Ti2Ni3Si/Ni3Ti coatings have excellent wear resistance and a low coefficient of friction under metallic dry sliding wear test conditions with hardened 0.45% C carbon steel as the silide-mating counterpart. The excellent tribological properties of the coating are attributed to the high hardness, strong covalent-dominant atomic bonds of the ternary metal silicide Ti2Ni3Si and to the high yield strength and strong yield anomaly of the intermetallic compound Ni3Ti.

  16. Ti(Ni,Cu) pseudobinary compounds as efficient negative electrodes for Ni-MH batteries

    NASA Astrophysics Data System (ADS)

    Emami, Hoda; Cuevas, Fermin; Latroche, Michel

    2014-11-01

    The effect of Ni by Cu substitution on the structural, solid-gas and electrochemical hydrogenation properties of TiNi has been investigated. Pseudo-binary TiNi1-xCux (x ≤ 0.5) compounds have been synthesized by induction melting. They crystallize in B2 structure above 350 K and either in B19‧ (x < 0.1) or B19 (0.2 ≤ x ≤ 0.5) at room temperature (RT). For all compounds, Pressure-Composition Isotherms at 423 K exhibit a single slopping plateau pressure within the range 10-3-1 MPa of hydrogen pressure revealing a metal to hydride transformation. Both the hydrogenation capacity and the hydride stability decrease with Cu-content. The hydrided pseudobinary compounds crystallize in the tetragonal S.G. I4/mmm structure as for TiNi hydride. The electrochemical discharge capacity increases with Cu content from 150 mAh g-1 for TiNi up to 300 mAh g-1 for TiNi0.8Cu0.2 and then decreases again for larger Cu amounts. Electrochemical isotherms and in-situ neutron diffraction measurements at RT demonstrate that such a capacity increase results from a metal to hydride phase transformation in which the hydride phase is destabilized by Cu substitution. The TiNi0.8Cu0.2 compound exhibits interesting cycling stability for 30 cycles and good high-rate capability at D/2 rate. This compound has promising electrochemical properties as compared to commercial LaNi5-type alloys with the advantage of being rare-earth metal free.

  17. Phase Equilibria of the Sn-Ni-Si Ternary System and Interfacial Reactions in Sn-(Cu)/Ni-Si Couples

    NASA Astrophysics Data System (ADS)

    Fang, Gu; Chen, Chih-chi

    2015-07-01

    Interfacial reactions in Sn/Ni-4.5 wt.%Si and Sn-Cu/Ni-4.5 wt.%Si couples at 250°C, and Sn-Ni-Si ternary phase equilibria at 250°C were investigated in this study. Ni-Si alloys, which are nonmagnetic, can be regarded as a diffusion barrier layer material in flip chip packaging. Solder/Ni-4.5 wt.%Si interfacial reactions are crucial to the reliability of soldered joints. Phase equilibria information is essential for development of solder/Ni-Si materials. No ternary compound is present in the Sn-Ni-Si ternary system at 250°C. Extended solubility of Si in the phases Ni3Sn2 and Ni3Sn is 3.8 and 6.1 at.%, respectively. As more Si dissolves in these phases their lattice constants decrease. No noticeable ternary solubility is observed for the other intermetallics. Interfacial reactions in solder/Ni-4.5 wt.%Si are similar to those for solder/Ni. Si does not alter the reaction phases. No Si solubility in the reaction phases was detected, although rates of growth of the reaction phases were reduced. Because the alloy Ni-4.5 wt.%Si reacts more slowly with solders than pure Ni, the Ni-4.5 wt.%Si alloy could be a potential new diffusion barrier layer material for flip chip packaging.

  18. Instrumentation of the Maumee River Crossing.

    DOT National Transportation Integrated Search

    2012-03-01

    This project has focused on the instrumentation, monitoring and testing of the main span unit of the VGCS, one of Ohio's first long-span, cable-stayed bridges and one of only a few dozen such bridges in service in the nation. This effort looked at fi...

  19. Atomic-scale dynamics of edge dislocations in Ni and concentrated solid solution NiFe alloys

    DOE PAGES

    Zhao, Shijun; Osetsky, Yuri N.; Zhang, Yanwen; ...

    2017-01-19

    Single-phase concentrated solid solution alloys (CSAs), including high entropy alloys, exhibit excellent mechanical properties compared to conventional dilute alloys. However, the origin of this observation is not clear yet because the dislocation properties in CSAs are poorly understood. In this work, the mobility of a <110>{111} edge dislocation in pure Ni and equiatomic solid solution Ni 0.5Fe 0.5 (NiFe) is studied using molecular dynamics simulations with different empirical potentials. The threshold stress to initiate dislocation movement in NiFe is found to be much higher compared to pure Ni. The drag coefficient of the dislocation motion calculated from the linear regimemore » of dislocation velocities versus applied stress suggests that the movement of dislocations in NiFe is strongly damped compared to that in Ni. The present results indicate that the mobility of edge dislocations in fcc CSAs are controlled by the fluctuations in local stacking fault energy caused by the local variation of alloy composition.« less

  20. Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.

    2016-02-22

    The coarsening of Ni in Ni–yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors.more » Here, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. The finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.« less

  1. Extreme temperatures in Southeast Asia caused by El Niño and worsened by global warming

    PubMed Central

    Thirumalai, Kaustubh; DiNezio, Pedro N.; Okumura, Yuko; Deser, Clara

    2017-01-01

    In April 2016, southeast Asia experienced surface air temperatures (SATs) that surpassed national records, exacerbated energy consumption, disrupted agriculture and caused severe human discomfort. Here we show using observations and an ensemble of global warming simulations the combined impact of the El Niño/Southern Oscillation (ENSO) phenomenon and long-term warming on regional SAT extremes. We find a robust relationship between ENSO and southeast Asian SATs wherein virtually all April extremes occur during El Niño years. We then quantify the relative contributions of long-term warming and the 2015–16 El Niño to the extreme April 2016 SATs. The results indicate that global warming increases the likelihood of record-breaking April extremes where we estimate that 29% of the 2016 anomaly was caused by warming and 49% by El Niño. These post-Niño Aprils can potentially be anticipated a few months in advance, and thus, help societies prepare for the projected continued increases in extremes. PMID:28585927

  2. Hybrid Energy Storage of Ni(OH)2-coated N-doped Graphene Aerogel//N-doped Graphene Aerogel for the Replacement of NiCd and NiMH Batteries.

    PubMed

    Sirisinudomkit, Pichamon; Iamprasertkun, Pawin; Krittayavathananon, Atiweena; Pettong, Tanut; Dittanet, Peerapan; Sawangphruk, Montree

    2017-04-25

    Although Nickel-Cadmium (NiCd) and Nickel-metal hydride (NiMH) batteries have been widely used, their drawbacks including toxic Cd and expensive La alloy at the negative electrodes, low energy density (40-60 Wh/kg for NiCd and 140-300 Wh/L for NiMH), low power density (150 W/kg for NiCd and 1000 W/kg for NiMH), and low working potential (1.2 V) limit their applications. In this work, Cd and La alloy were replaced with N-doped reduced graphene oxide aerogel (N-rGO ae ) providing a hybrid energy storage (HES) having the battery and supercapacitor effects. The HES of Ni(OH) 2 -coated N-rGO ae //N-rGO ae provides 1.5 V, a specific energy of 146 Wh/kg, a maximum specific power of 7705 W/kg, and high capacity retention over 84.6% after 5000 cycles. The mass change at the positive electrode during charging/discharging is 8.5 µg cm -2 owing to the insertion/desertion of solvated OH - into the α-Ni(OH) 2 -coated N-rGO ae . At the negative electrode, the mass change of the solvated K + , physically adsorbed/desorbed to the N-rGO ae , is 7.5 μg cm -2 . In situ X-ray absorption spectroscopy (XAS) shows highly reversible redox reaction of α-Ni(OH) 2 . The as-fabricated device without using toxic Cd and expensive La alloy has a potential as a candidate of NiCd and NiMH.

  3. Phonon Dispersion in Amorphous Ni-Alloys

    NASA Astrophysics Data System (ADS)

    Vora, A. M.

    2007-06-01

    The well-known model potential is used to investigate the longitudinal and transverse phonon dispersion curves for six Ni-based binary amorphous alloys, viz. Ni31Dy69, Ni33Y67, Ni36Zr64, Ni50Zr50, Ni60 Nb40, and Ni81B19. The thermodynamic and elastic properties are also computed from the elastic limits of the phonon dispersion curves. The theoretical approach given by Hubbard-Beeby is used in the present study to compute the phonon dispersion curves. Five local field correction functions proposed by Hartree, Taylor, Ichimaru-Utsumi, Farid et al. and Sarkar et al. are employed to see the effect of exchange and correlation in the aforesaid properties.

  4. [A national multicentre study on nosocomial infections in PICU].

    PubMed

    Jordan García, I; Arriourtúa, A Bustinza; Torre, J A Concha; Antón, J Gil; Vicente, J C de Carlos; González, C Téllez

    2014-01-01

    Nosocomial infection (NI) is a common complication in paediatric critical care units (PICU), with an associated mortality up to 11%. To describe NI epidemiology in the national PICU. To initiate an standard NI control measures to obtain paediatric incidence rates. Multicentre prospective study from 1 to 31 march 2007. Centre Disease Control diagnosis and methodological criteria were used. It was specially analyzed NI related to invasive devices: central venous catheter (CVC), mechanical ventilation (MV), urinary catheter (UC). There were recruited 300 patients from 6 PICU, with 17 NI episodes in 16 patients (5,3% from admitted). NI rates resulted in 13,8 infections/1000 patients-day. Middle age from infected patients was 2,31 years (± 3,43), 9 males. Risk factors were found in 7 cases. NI location was: catheter-related bloodstream infection in 7 patients (6,7/1000 days CVC), ventilator associated pneumonia in 4 (9,4/1000 MV days), urinary-tract infection associated with UC in 4 (5,5/1000 UC days), one case of primary bloodstream infection and one surgical site infection. Isolated microorganisms were: 9 gram negatives bacillus, 4 Candida, 2 plasmocoagulase negative staphylococcus, 1 Haemophilus and 1 Staphylococcus aureus. Seven isolations were resistant microorganisms. There weren't any died related to NI. NI epidemiology was similar to published data in our near countries. NI surveillance, with a standardized method of analysis is essential to the NI correct manage. Copyright © 2010 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  5. Long Term Performance Retention Test Using High Power COTS NiCd and NiMH Cells

    NASA Technical Reports Server (NTRS)

    Hall, Dan; Darcy, Eric; Strangways, Brad; Nelson, Tim

    2003-01-01

    This slide presentation reviews the tests and results for performance retention of high powered commercial off the shelf (COTS) NiCd, and NiMH cells. Electromechanical actuators for space flight requires short duration high power batteries. The concern is that NiCd battery designs demonstrate an unfavorable power degradation after long periods of inactivity. Cycling can recover some of the decay, but this reduces the readiness that these batteries must have. Two 5-cell SubC stick test batteries ere chosen using NiCd and NiMH were tested and then the differences for charge maintenance were compared.

  6. Phase transformation and deformation behavior of NiTi-Nb eutectic joined NiTi wires

    PubMed Central

    Wang, Liqiang; Wang, Cong; Zhang, Lai-Chang; Chen, Liangyu; Lu, Weijie; Zhang, Di

    2016-01-01

    NiTi wires were brazed together via eutectic reaction between NiTi and Nb powder deposited at the wire contact region. Phase transformation and deformation behavior of the NiTi-Nb eutectic microstructure were investigated using transmission electron microscopy (TEM) and cyclic loading-unloading tests. Results show that R phase and B19′ martensite transformation are induced by plastic deformation. R phase transformation, which significantly contributes to superelasticity, preferentially occurs at the interfaces between NiTi and eutectic region. Round-shaped Nb-rich phase with rod-like and lamellar-type eutectics are observed in eutectic regions. These phases appear to affect the deformation behavior of the brazed NiTi-Nb region via five distinct stages in stress-strain curves: (I) R phase reorientation, (II) R phase transformation from parent phase, (III) elastic deformation of reoriented martensite accompanied by the plastic deformation of Nb-rich phase and lamellar NiTi-Nb eutectic, (IV) B19′ martensitic transformation, and (V) plastic deformation of the specimen. PMID:27049025

  7. Low-temperature CO oxidation on Ni(111) and on a Au/Ni(111) surface alloy.

    PubMed

    Knudsen, Jan; Merte, Lindsay R; Peng, Guowen; Vang, Ronnie T; Resta, Andrea; Laegsgaard, Erik; Andersen, Jesper N; Mavrikakis, Manos; Besenbacher, Flemming

    2010-08-24

    From an interplay between scanning tunneling microscopy, temperature programmed desorption, X-ray photoelectron spectroscopy, and density functional theory calculations we have studied low-temperature CO oxidation on Au/Ni(111) surface alloys and on Ni(111). We show that an oxide is formed on both the Ni(111) and the Au/Ni(111) surfaces when oxygen is dosed at 100 K, and that CO can be oxidized at 100 K on both of these surfaces in the presence of weakly bound oxygen. We suggest that low-temperature CO oxidation can be rationalized by CO oxidation on O(2)-saturated NiO(111) surfaces, and show that the main effect of Au in the Au/Ni(111) surface alloy is to block the formation of carbonate and thereby increase the low-temperature CO(2) production.

  8. NiO-Microflower Formed by Nanowire-weaving Nanosheets with Interconnected Ni-network Decoration as Supercapacitor Electrode

    PubMed Central

    Ci, Suqing; Wen, Zhenhai; Qian, Yuanyuan; Mao, Shun; Cui, Shumao; Chen, Junhong

    2015-01-01

    We propose a ‘weaving’ evolution mechanism, by systematically investigating the products obtained in controlled experiments, to demonstrate the formation of Ni-based ‘microflowers’ which consists of multiple characteristic dimensions, in which the three dimensional (3D) NiO ‘microflower’ is constructed by a two-dimensional (2D) nanosheet framework that is derived from weaving one-dimensional (1D) nanowires. We found such unique nanostructures are conducive for the generation of an electrically conductive Ni-network on the nanosheet surface after being exposed to a reducing atmosphere. Our study offers a promising strategy to address the intrinsic issue of poor electrical conductivity for NiO-based materials with significant enhancement of utilization of NiO active materials, leading to a remarkable improvement in the performance of the Ni-NiO microflower based supercapacitor. The optimized Ni-NiO microflower material showed a mass specific capacitance of 1,828 F g−1, and an energy density of 15.9 Wh kg−1 at a current density of 0.5 A g−1. This research not only contributes to understanding the formation mechanism of such ‘microflower’ structures but also offers a promising route to advance NiO based supercapacitor given their ease of synthesis, low cost, and long-term stability. PMID:26165386

  9. Access to Formally Ni(I) States in a Heterobimetallic NiZn System

    PubMed Central

    Uyeda, Christopher

    2014-01-01

    Heterobimetallic NiZn complexes featuring metal centers in distinct coordination environments have been synthesized using diimine-dioxime ligands as binucleating scaffolds. A tetramethylfuran-containing ligand derivative enables a stable one-electron-reduced S = 1/2 species to be accessed using Cp2Co as a chemical reductant. The resulting pseudo-square planar complex exhibits spectroscopic and crystallographic characteristics of a ligand-centered radical bound to a Ni(II) center. Upon coordination of a π-acidic ligand such as PPh3, however, a five-coordinate Ni(I) metalloradical is formed. The electronic structures of these reduced species provide insight into the subtle effects of ligand structure on the potential and reversibility of the NiII/I couple for complexes of redox-active tetraazamacrocycles. PMID:25614786

  10. Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes

    DOE PAGES

    Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.; ...

    2016-02-25

    The coarsening of Ni in Ni–yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors.more » Here in this paper, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. In conclusion, the finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.« less

  11. Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.

    The coarsening of Ni in Ni–yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors.more » Here in this paper, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. In conclusion, the finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.« less

  12. Teaching a Course on Meteorological Instruments.

    ERIC Educational Resources Information Center

    Kohler, Fred

    A meteorological instruments course that provided undergraduate geography students the opportunity to use and/or observe meteorological equipment while also preparing for possible internships with the National Weather Service is evaluated and suggestions for improving it in the future are offered. The paper first provides a general course…

  13. Monte Carlo simulations of neutron-scattering instruments using McStas

    NASA Astrophysics Data System (ADS)

    Nielsen, K.; Lefmann, K.

    2000-06-01

    Monte Carlo simulations have become an essential tool for improving the performance of neutron-scattering instruments, since the level of sophistication in the design of instruments is defeating purely analytical methods. The program McStas, being developed at Risø National Laboratory, includes an extension language that makes it easy to adapt it to the particular requirements of individual instruments, and thus provides a powerful and flexible tool for constructing such simulations. McStas has been successfully applied in such areas as neutron guide design, flux optimization, non-Gaussian resolution functions of triple-axis spectrometers, and time-focusing in time-of-flight instruments.

  14. netherland hydrological modeling instrument

    NASA Astrophysics Data System (ADS)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    Netherlands Hydrological Modeling Instrument A decision support system for water basin management. J.C. Hoogewoud , W.J. de Lange ,A. Veldhuizen , G. Prinsen , The Netherlands Hydrological modeling Instrument (NHI) is the center point of a framework of models, to coherently model the hydrological system and the multitude of functions it supports. Dutch hydrological institutes Deltares, Alterra, Netherlands Environmental Assessment Agency, RWS Waterdienst, STOWA and Vewin are cooperating in enhancing the NHI for adequate decision support. The instrument is used by three different ministries involved in national water policy matters, for instance the WFD, drought management, manure policy and climate change issues. The basis of the modeling instrument is a state-of-the-art on-line coupling of the groundwater system (MODFLOW), the unsaturated zone (metaSWAP) and the surface water system (MOZART-DM). It brings together hydro(geo)logical processes from the column to the basin scale, ranging from 250x250m plots to the river Rhine and includes salt water flow. The NHI is validated with an eight year run (1998-2006) with dry and wet periods. For this run different parts of the hydrology have been compared with measurements. For instance, water demands in dry periods (e.g. for irrigation), discharges at outlets, groundwater levels and evaporation. A validation alone is not enough to get support from stakeholders. Involvement from stakeholders in the modeling process is needed. There fore to gain sufficient support and trust in the instrument on different (policy) levels a couple of actions have been taken: 1. a transparent evaluation of modeling-results has been set up 2. an extensive program is running to cooperate with regional waterboards and suppliers of drinking water in improving the NHI 3. sharing (hydrological) data via newly setup Modeling Database for local and national models 4. Enhancing the NHI with "local" information. The NHI is and has been used for many

  15. The Many Faces of Graphene as Protection Barrier. Performance under Microbial Corrosion and Ni Allergy Conditions

    PubMed Central

    Gentil, Dana; del Campo, Valeria; Henrique Rodrigues da Cunha, Thiago; Henríquez, Ricardo; Garín, Carolina; Ramírez, Cristian; Flores, Marcos; Seeger, Michael

    2017-01-01

    In this work we present a study on the performance of CVD (chemical vapor deposition) graphene coatings grown and transferred on Ni as protection barriers under two scenarios that lead to unwanted metal ion release, microbial corrosion and allergy test conditions. These phenomena have a strong impact in different fields considering nickel (or its alloys) is one of the most widely used metals in industrial and consumer products. Microbial corrosion costs represent fractions of national gross product in different developed countries, whereas Ni allergy is one of the most prevalent allergic conditions in the western world, affecting around 10% of the population. We found that grown graphene coatings act as a protective membrane in biological environments that decreases microbial corrosion of Ni and reduces release of Ni2+ ions (source of Ni allergic contact hypersensitivity) when in contact with sweat. This performance seems not to be connected to the strong orbital hybridization that Ni and graphene interface present, indicating electron transfer might not be playing a main role in the robust response of this nanostructured system. The observed protection from biological environment can be understood in terms of graphene impermeability to transfer Ni2+ ions, which is enhanced for few layers of graphene grown on Ni. We expect our work will provide a new route for application of graphene as a protection coating for metals in biological environments, where current strategies have shown short-term efficiency and have raised health concerns. PMID:29292763

  16. The Many Faces of Graphene as Protection Barrier. Performance under Microbial Corrosion and Ni Allergy Conditions.

    PubMed

    Parra, Carolina; Montero-Silva, Francisco; Gentil, Dana; Del Campo, Valeria; Henrique Rodrigues da Cunha, Thiago; Henríquez, Ricardo; Häberle, Patricio; Garín, Carolina; Ramírez, Cristian; Fuentes, Raúl; Flores, Marcos; Seeger, Michael

    2017-12-08

    In this work we present a study on the performance of CVD (chemical vapor deposition) graphene coatings grown and transferred on Ni as protection barriers under two scenarios that lead to unwanted metal ion release, microbial corrosion and allergy test conditions. These phenomena have a strong impact in different fields considering nickel (or its alloys) is one of the most widely used metals in industrial and consumer products. Microbial corrosion costs represent fractions of national gross product in different developed countries, whereas Ni allergy is one of the most prevalent allergic conditions in the western world, affecting around 10% of the population. We found that grown graphene coatings act as a protective membrane in biological environments that decreases microbial corrosion of Ni and reduces release of Ni 2+ ions (source of Ni allergic contact hypersensitivity) when in contact with sweat. This performance seems not to be connected to the strong orbital hybridization that Ni and graphene interface present, indicating electron transfer might not be playing a main role in the robust response of this nanostructured system. The observed protection from biological environment can be understood in terms of graphene impermeability to transfer Ni 2+ ions, which is enhanced for few layers of graphene grown on Ni. We expect our work will provide a new route for application of graphene as a protection coating for metals in biological environments, where current strategies have shown short-term efficiency and have raised health concerns.

  17. Effect of solute atoms on swelling in Ni alloys and pure Ni under He + ion irradiation

    NASA Astrophysics Data System (ADS)

    Wakai, E.; Ezawa, T.; Imamura, J.; Takenaka, T.; Tanabe, T.; Oshima, R.

    2002-12-01

    The effects of solute atoms on microstructural evolutions have been investigated using Ni alloys under 25 keV He + irradiation at 500 °C. The specimens used were pure Ni, Ni-Si, Ni-Co, Ni-Cu, Ni-Mn and Ni-Pd alloys with different volume size factors. The high number densities of dislocation loops about 1.5×10 22 m -3 were formed in the specimens irradiated to 1×10 19 ions/m 2, and they were approximately equivalent, except for Ni-Si. The mean size of loops tended to increase with the volume size factor of solute atoms. In a dose of 4×10 20 ions/m 2, the swelling was changed from 0.2% to 4.5%, depending on the volume size factors. The number densities of bubbles tended to increase with the absolute values of the volume size factor, and the swelling increased with the volume size factors. This suggests that the mobility of helium and vacancy atoms may be influenced by the interaction of solute atoms with them.

  18. NiCoO2 flowers grown on the aligned-flakes coated Ni foam for application in hybrid energy storage

    NASA Astrophysics Data System (ADS)

    Xu, Xiaoyang; Zhao, Huilin; Zhou, JingKuo; Xue, Ruinan; Gao, Jianping

    2016-10-01

    Many NiCoO2 flowers with an average diameter of about 4 μm were grown on the NiCoO2 flakes coated Ni foam (denoted as NiCoO2/Ni foam) through a simple hydrothermal method and confirmed by scanning and transmission electron microscopies, X-ray diffraction and X-ray photoelectron spectrum measurements. The NiCoO2/Ni foam with high specific area and porosity was directly used as the working electrode without any binders. The measured specific capacitance of NiCoO2 grown on Ni foam is 756 F/g at 0.75 A/g using a three-electrode setup in 1 M KOH. Considering the high capacity of NiCoO2 and the good stability of rGO, the NiCoO2/Ni foam//rGO hybrid supercapacitor combining NiCoO2/Ni foam and rGO shows very good properties, such as high specific capacitance (82 F/g at 2 A/g based on the total mass of active materials), high energy density (25.7 Wh/kg at 1500 W/kg based on the total mass of active materials), good stability (about 90% capacitance retention after 2000-cycle at 100 mV/s), and low charge ion transfer resistance.

  19. Blending Cr 2O 3 into a NiO-Ni electrocatalyst for sustained water splitting

    DOE PAGES

    Gong, Ming; Zhou, Wu; Kenney, Michael James; ...

    2015-08-24

    The rising H 2 economy demands active and durable electrocatalysts based on low-cost, earth-abundant materials for water electrolysis/photolysis. Here we report nanoscale Ni metal cores over-coated by a Cr 2O 3-blended NiO layer synthesized on metallic foam substrates. The Ni@NiO/Cr 2O 3 triphase material exhibits superior activity and stability similar to Pt for the hydrogen-evolution reaction in basic solutions. The chemically stable Cr 2O 3 is crucial for preventing oxidation of the Ni core, maintaining abundant NiO/Ni interfaces as catalytically active sites in the heterostructure and thus imparting high stability to the hydrogen-evolution catalyst. The highly active and stable electrocatalystmore » enables an alkaline electrolyzer operating at 20 mA cm –2 at a voltage lower than 1.5 V, lasting longer than 3 weeks without decay. Thus, the non-precious metal catalysts afford a high efficiency of about 15 % for light-driven water splitting using GaAs solar cells.« less

  20. Characterization and electrochemical properties of Ni(Si)/Ni5Si2 multiphase coatings prepared by HVOF spraying

    NASA Astrophysics Data System (ADS)

    Verdian, M. M.; Raeissi, K.; Salehi, M.

    2012-11-01

    Ni(Si)/Ni5Si2 powders were produced by mechanical alloying (MA) of Ni-25 at.% Si powder mixture. Then, the as-milled powders were sprayed onto copper substrate using high velocity oxy-fuel (HVOF) process. The phase composition and microstructure of the coatings were examined by X-ray diffractometry and scanning electron microscopy. Polarization tests and electrochemical impedance spectroscopy (EIS) measurements were also employed to study corrosion performance of the coatings in 3.5% NaCl solution. The results showed that although single phase Ni3Si was formed during annealing of Ni(Si)/Ni5Si2 powders, but, only Ni(Si) and Ni5Si2 are present in HVOF coatings and no new phase has been formed during spraying. The coatings had microhardness up to 746 HV0.05. Further investigations showed the corrosion performance of multiphase coatings in 3.5% NaCl solution was better than that of copper substrate. The phase transitions during MA, HVOF and annealing processes were discussed in association with Ni-Si phase diagram and nature of each process.

  1. The influence of simulated clinical use on the flexibility of rotary ProTaper Universal, K3 and EndoSequence nickel-titanium instruments.

    PubMed

    Viana, A C D; Pereira, E S J; Bahia, M G A; Buono, V T L

    2013-09-01

    To investigate the influence of cyclic flexural and torsional loading on the flexibility of ProTaper Universal, K3 and EndoSequence nickel-titanium instruments, in view of the hypothesis that these types of loading would decrease the flexibility of the selected NiTi rotary files. The instruments evaluated were S2 and F1 ProTaper Universal, sizes 20 and 25, .06 taper K3, and sizes 20 and 25, .06 taper EndoSequence. Flexibility was determined by 45° bending tests according to ISO 3630-1 specification. Values of the bending moment (MB ) obtained with new instruments were considered as the control group (CG). Bending tests were then conducted in instruments previously fatigued to one-fourth and three-fourths of their average fatigue life (fatigue groups, FG¼ and FG¾), as well as after cyclic torsional loading (torsional group, TG). Fatigue tests were carried out in a bench device that allowed the files to rotate freely inside an artificial canal with an angle of curvature of 45° and a radius of 5 mm. Cyclic torsional loading tests were performed that entailed rotating the instrument from zero angular deflection to 180° and then returning to zero applied torque in 20 cycles. Data were analysed using one-way analysis of variance at a significance level of 5%. Simulated clinical use by means of flexural fatigue tests did not affect the flexibility of the instruments, except for a significant increase in flexibility observed in a few instruments (P < 0.05). In addition, comparative statistical analyses between the values of MB measured in new instruments and after cyclic torsional loading showed no significant differences between them (P > 0.05). The flexibility of rotary ProTaper Universal, K3 and EndoSequence NiTi instruments, measured in bending tests, was not adversely affected by simulated clinical use in curved root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. One-step facile synthesis of Ni2P/C as cathode material for Ni/Zn aqueous secondary battery

    NASA Astrophysics Data System (ADS)

    Li, JiLan; Chen, ChangGuo

    2018-01-01

    Nickel phosphides/carbon(Ni2P/C) composites have been successfully synthesized via a simple one-pot hydrothermal method using glucose as carbon source for the first time. By contrast, the pure Ni2P was prepared under the same conditions without glucose. The results show that glucose not only provide the carbon source, but also prevent the aggregation of Ni2P particles. The as-obtained Ni2P/C composites and pure Ni2P were used as cathode material for alkaline Ni/Zn battery. Owing to unique Ni2P/C composites and loose, Ultra thin flower-like shape the synthesized Ni2P/C material delivers high capacity of 176 mAh g-1 at 1 A g-1 and 82 mAh g-1 at 5 A g-1 current density in Ni2P/C-Zn battery. Moreover, it shows a good cycling life that capacity fading only about 6.2% after 1500 cycles. All of these indicate that the prepared Ni2P/C composites may be a new promising cathode material for Ni-Zn rechargeable battery.

  3. Epochal changes in the association between malaria epidemics and El Niño in Sri Lanka

    PubMed Central

    Zubair, Lareef; Galappaththy, Gawrie N; Yang, Hyemin; Chandimala, Janaki; Yahiya, Zeenas; Amerasinghe, Priyanie; Ward, Neil; Connor, Stephen J

    2008-01-01

    Background El Niño events were suggested as a potential predictor for malaria epidemics in Sri Lanka based on the coincidence of nine out of 16 epidemics with El Niño events from 1870 to 1945. Here the potential for the use of El Niño predictions to anticipate epidemics was examined using enhanced climatic and epidemiological data from 1870 to 2000. Methods The epidemics start years were identified by the National Malaria Control Programme and verified against epidemiological records for consistency. Monthly average rainfall climatologies were estimated for epidemic and non-epidemic years; as well El Niño, Neutral and La Niña climatic phases. The relationship between El Niño indices and epidemics was examined to identify 'epochs' of consistent association. The statistical significance of the association between El Niño and epidemics for different epochs was characterized. The changes in the rainfall-El Niño relationships over the decade were examined using running windowed correlations. The anomalies in rainfall climatology during El Niño events for different epochs were compared. Results The relationship between El Niño and epidemics from 1870 to 1927 was confirmed. The anomalies in monthly average rainfall during El Niño events resembled the anomalies in monthly average rainfall during epidemics during this period. However, the relationship between El Niño and epidemics broke down from 1928 to 1980. Of the three epidemics in these six decades, only one coincided with an El Niño. Not only did this relationship breakdown but epidemics were more likely to occur in periods with a La Niña tendency. After 1980, three of four epidemics coincided with El Niño. Conclusion The breakdown of the association between El Niño and epidemics after 1928 is likely due to an epochal change in the El Niño-rainfall relationship in Sri Lanka around the 1930's. It is unlikely that this breakdown is due to the insecticide spraying programme that began in 1945 since the

  4. Solution growth of NiO nanosheets supported on Ni foam as high-performance electrodes for supercapacitors

    NASA Astrophysics Data System (ADS)

    Yan, Hailong; Zhang, Deyang; Xu, Jinyou; Lu, Yang; Liu, Yunxin; Qiu, Kangwen; Zhang, Yihe; Luo, Yongsong

    2014-08-01

    Well-aligned nickel oxide (NiO) nanosheets with the thickness of a few nanometers supported on a flexible substrate (Ni foam) have been fabricated by a hydrothermal approach together with a post-annealing treatment. The three-dimensional NiO nanosheets were further used as electrode materials to fabricate supercapacitors, with high specific capacitance of 943.5, 791.2, 613.5, 480, and 457.5 F g-1 at current densities of 5, 10, 15, 20, and 25 A g-1, respectively. The NiO nanosheets combined well with the substrate. When the electrode material was bended, it can still retain 91.1% of the initial capacitance after 1,200 charging/discharging cycles. Compared with Co3O4 and NiO nanostructures, the specific capacitance of NiO nanosheets is much better. These characteristics suggest that NiO nanosheet electrodes are promising for energy storage application with high power demands.

  5. Study on the formation of graphene by ion implantation on Cu, Ni and CuNi alloy

    NASA Astrophysics Data System (ADS)

    Kim, Janghyuk; Kim, Hong-Yeol; Jeon, Jeong Heum; An, Sungjoo; Hong, Jongwon; Kim, Jihyun

    2018-09-01

    This study identifies the details for direct synthesis of graphene by carbon ion implantation on Cu, Ni and CuNi alloy. Firstly, diffusion and concentration of carbon atoms in Cu and Ni are estimated separately. The concentrations of carbon atoms near the surfaces of Cu and Ni after carbon ion implantation and subsequent thermal annealing were correlated with the number of atoms and with the coverage or thickness of graphene. Systematic experiments showed that the Cu has higher carbon diffusivity and graphene coverage than Ni but higher temperatures and longer annealing times are required to synthesize graphene, similar to those in chemical vapor deposition method. The CuNi system shows better graphene coverage and quality than that on a single metal catalyst even after a short annealing time, as it has larger carbon diffusivity and lower carbon solubility than Ni and shows lower activation energy than Cu.

  6. Solution growth of NiO nanosheets supported on Ni foam as high-performance electrodes for supercapacitors.

    PubMed

    Yan, Hailong; Zhang, Deyang; Xu, Jinyou; Lu, Yang; Liu, Yunxin; Qiu, Kangwen; Zhang, Yihe; Luo, Yongsong

    2014-01-01

    Well-aligned nickel oxide (NiO) nanosheets with the thickness of a few nanometers supported on a flexible substrate (Ni foam) have been fabricated by a hydrothermal approach together with a post-annealing treatment. The three-dimensional NiO nanosheets were further used as electrode materials to fabricate supercapacitors, with high specific capacitance of 943.5, 791.2, 613.5, 480, and 457.5 F g(-1) at current densities of 5, 10, 15, 20, and 25 A g(-1), respectively. The NiO nanosheets combined well with the substrate. When the electrode material was bended, it can still retain 91.1% of the initial capacitance after 1,200 charging/discharging cycles. Compared with Co3O4 and NiO nanostructures, the specific capacitance of NiO nanosheets is much better. These characteristics suggest that NiO nanosheet electrodes are promising for energy storage application with high power demands.

  7. Modeling and Characterization of the Magnetocaloric Effect in Ni2MnGa Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nicholson, Don M; Odbadrakh, Khorgolkhuu; Shassere, Benjamin

    2014-01-01

    Magnetic shape memory alloys have great promise as magneto-caloric effect refrigerant materials due to their combined magnetic and structural transitions. Computational and experimental research is reported on the Ni2MnGa material system. The magnetic states of this system are explored using the Wang-Landau statistical approach in conjunction with the Locally Self-consistent Multiple-Scattering method. The effects of alloying agents on the transition temperatures of the Ni2MnGa alloy are investigated using differential scanning calorimetry and superconducting quantum interference device. Experiments are performed at the Spallation Neutron Source at Oak Ridge National Laboratory to observe the structural and magnetic phase transformations.

  8. Performance of the Prognocean Plus system during the El Niño 2015/2016: predictions of sea level anomalies as tools for forecasting El Niño

    NASA Astrophysics Data System (ADS)

    Świerczyńska-Chlaściak, Małgorzata; Niedzielski, Tomasz; Miziński, Bartłomiej

    2017-04-01

    usefulness of sea level anomaly forecasts in predicting phenomena that are controlled by the ocean-atmosphere processes, such as El Niño Southern Oscillation or North Atlantic Oscillation. The results may support further investigations into long-term forecasting of the quantitative indices of these oscillations, solely based on prognoses of sea level change. In particular, comparing the accuracies of prognoses of the North Atlantic Oscillation index remains one of the tasks of the research project no. 2016/21/N/ST10/03231, financed by the National Science Center of Poland.

  9. Effect of P impurity on mechanical properties of NiAl Σ5 grain boundary: From perspectives of stress and energy

    NASA Astrophysics Data System (ADS)

    Hu, Xue-Lan; Zhao, Ruo-Xi; Deng, Jiang-Ge; Hu, Yan-Min; Song, Qing-Gong

    2018-03-01

    In this paper, we employ the first-principle total energy method to investigate the effect of P impurity on mechanical properties of NiAl grain boundary (GB). According to “energy”, the segregation of P atom in NiAlΣ5 GB reduces the cleavage energy and embrittlement potential, demonstrating that P impurity embrittles NiAlΣ5 GB. The first-principle computational tensile test is conducted to determine the theoretical tensile strength of NiAlΣ5 GB. It is demonstrated that the maximum ideal tensile strength of NiAlΣ5 GB with P atom segregation is 144.5 GPa, which is lower than that of the pure NiAlΣ5 GB (164.7 GPa). It is indicated that the segregation of P weakens the theoretical strength of NiAlΣ5 GB. The analysis of atomic configuration shows that the GB fracture is caused by the interfacial bond breaking. Moreover, P is identified to weaken the interactions between Al–Al bonds and enhance Ni–Ni bonds. Project supported by the National Natural Science Foundation of China (Grant Nos. 11404396 and 51201181) and the Subject Construction Fund of Civil Aviation University of China (Grant No. 000032041102).

  10. NiSe-Ni0.85 Se Heterostructure Nanoflake Arrays on Carbon Paper as Efficient Electrocatalysts for Overall Water Splitting.

    PubMed

    Chen, Yajie; Ren, Zhiyu; Fu, Huiying; Zhang, Xin; Tian, Guohui; Fu, Honggang

    2018-06-01

    Fabricating cost-effective, bifunctional electrocatalysts for both the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) in basic media is critical for renewable energy generation. Here, NiSe/CP, Ni 0.85 Se/CP, and NiSe-Ni 0.85 Se/CP heterostructure catalysts with different phase constitutions are successfully prepared through in situ selenylation of a NiO nanoflake array oriented on carbon paper (CP) by tuning the original Ni/Se molar ratio of the raw materials. The relationship between the crystal phase component and electrocatalytic activity is systematically studied. Benefiting from the synergetic effect of the intrinsic metallic state, facile charge transport, abundant catalytic active sites, and multiple electrolyte transmission paths, the optimized NiSe-Ni 0.85 Se/CP exhibits a remarkably higher catalytic activity for both the HER and OER than single-phase NiSe/CP and Ni 0.85 Se/CP. A current density of 10 mA cm -2 at 1.62 V and a high stability can be obtained by using NiSe-Ni 0.85 Se/CP as both the cathode and anode for overall water splitting under alkaline conditions. Density functional theory calculations confirm that H and OH - can be more easily adsorbed on NiSe-Ni 0.85 Se than on NiSe and Ni 0.85 Se. This study paves the way for enhancing the overall water splitting performance of nickel selenides by fabricating heterophase junctions using nickel selenides with different phases. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Apical extrusion of Enterococcus faecalis using three different rotary instrumentation techniques: an in vitro study.

    PubMed

    Taneja, Sonali; Kumari, Manju; Barua, Madhumita; Dudeja, Chetna; Malik, Meeta

    2015-01-01

    To compare the apical extrusion of Enterococcus faecalis after instrumentation with three different Ni-Ti rotary instruments- An in vitro study. In vitro study Methods and Material: Forty freshly extracted mandibular premolars were mounted in bacteria collection apparatus and root canals were contaminated with a suspension of Enterococcus faecalis. The contaminated teeth were divided into 4 groups of 10 teeth each according to rotary system used for instrumentation: Group1: Hyflex files, Group 2: GTX files, Group 3: Protaper files and Group 4: control group (no instrumentation). Bacteria extruded after preparations were collected into vials and microbiological samples were incubated in BHI broth for 24 hrs. The colony forming units were determined for each sample. Statistical analysis was done using one way ANOVA followed by post hoc independent " t" test. GTX files extruded least amount of bacteria followed by Hyflex files. Maximum extrusion of E. faecalis was seen in rotary Protaper group. Least amount of extrusion was seen with GTX files followed by Hyflex files and then rotary Protaper system.

  12. Quantitative Assessment of Apical Debris Extrusion and Intracanal Debris in the Apical Third, Using Hand Instrumentation and Three Rotary Instrumentation Systems

    PubMed Central

    H.K., Sowmya; T.S., Subhash; Goel, Beena Rani; T.N., Nandini; Bhandi, Shilpa H.

    2014-01-01

    Introduction: Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Methodology: Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. Results: The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Conclusion: Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one

  13. An Update on Improvements to NiCE Support for PROTEUS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, Andrew; McCaskey, Alexander J.; Billings, Jay Jay

    2015-09-01

    The Department of Energy Office of Nuclear Energy's Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has supported the development of the NEAMS Integrated Computational Environment (NiCE), a modeling and simulation workflow environment that provides services and plugins to facilitate tasks such as code execution, model input construction, visualization, and data analysis. This report details the development of workflows for the reactor core neutronics application, PROTEUS. This advanced neutronics application (primarily developed at Argonne National Laboratory) aims to improve nuclear reactor design and analysis by providing an extensible and massively parallel, finite-element solver for current and advanced reactor fuel neutronicsmore » modeling. The integration of PROTEUS-specific tools into NiCE is intended to make the advanced capabilities that PROTEUS provides more accessible to the nuclear energy research and development community. This report will detail the work done to improve existing PROTEUS workflow support in NiCE. We will demonstrate and discuss these improvements, including the development of flexible IO services, an improved interface for input generation, and the addition of advanced Fortran development tools natively in the platform.« less

  14. A new 55Ni(p,g) rate and its implications on the rp-process

    NASA Astrophysics Data System (ADS)

    Ong, Wei Jia; Langer, Christoph; Montes, Fernando; Nscl E11024 Collaboration

    2016-09-01

    The low-lying energy levels of proton-rich 56Cu have been extracted using in-beam γ-ray spectroscopy with the state-of-the-art γ-ray tracking array GRETINA in conjunction with the S800 spectrograph at the National Superconducting Cyclotron Laboratory at Michigan State University. Excited states in 56Cu are resonances in the 55Ni(p, γ)56Cu reaction, which is a part of the rp-process in type I x-ray bursts. To resolve existing ambiguities in the reaction Q-value, a more localized IMME mass fit is used resulting in Q = 639 +/- 82 keV. We derive the first experimentally-constrained thermonuclear reaction rate for 55Ni(p, γ)56Cu. We find that, with this new rate, the rp-process may bypass the 56Ni waiting point via the 55Ni(p, γ) reaction for typical x-ray burst conditions with a branching of up to 40 % . We also identify additional nuclear physics uncertainties that need to be addressed before drawing final conclusions about the rp-process reaction flow in the 56Ni region. This work was supported by NSF Grants PHY11-02511, PHY10-68217, PHY14-04442, PHY08-22648 and PHY14-30152.

  15. GeV ion irradiation of NiFe and NiCo: Insights from MD simulations and experiments

    DOE PAGES

    Leino, Aleksi A.; Samolyuk, German D.; Sachan, Ritesh; ...

    2018-03-31

    Concentrated solid solution alloys have attracted rapidly increasing attention due to their potential for designing materials with high tolerance to radiation damage. To tackle the effects of chemical complexity in defect dynamics and radiation response, we present in this paper a computational study on swift heavy ion induced effects in Ni and equiatomic Ni -based alloys (Ni 50Fe 50, Ni 50Co 50) using two-temperature molecular dynamics simulations (2T-MD). The electronic heat conductivity in the two-temperature equations is parameterized from the results of first principles electronic structure calculations. A bismuth ion (1.542 GeV) is selected and single impact simulations performed inmore » each target. We study the heat flow in the electronic subsystem and show that alloying Ni with Co or Fe reduces the heat dissipation from the impact by the electronic subsystem. Simulation results suggest no melting or residual damage in pure Ni while a cylindrical region melts along the ion propagation path in the alloys. In Ni 50Co 50 the damage consists of a dislocation loop structure (d = 2 nm) and isolated point defects, while in Ni 50Fe 50, a defect cluster (d = 4 nm) along the ion path is, in addition, formed. The simulation results are supported by atomic-level structural and defect characterizations in bismuth-irradiated Ni and Ni 50Fe 50. Finally, the significance of the 2T-MD model is demonstrated by comparing the results to those obtained with an instantaneous energy deposition model without consideration of e-ph interactions in pure Ni and by showing that it leads to a different qualitative behavior.« less

  16. GeV ion irradiation of NiFe and NiCo: Insights from MD simulations and experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leino, Aleksi A.; Samolyuk, German D.; Sachan, Ritesh

    Concentrated solid solution alloys have attracted rapidly increasing attention due to their potential for designing materials with high tolerance to radiation damage. To tackle the effects of chemical complexity in defect dynamics and radiation response, we present in this paper a computational study on swift heavy ion induced effects in Ni and equiatomic Ni -based alloys (Ni 50Fe 50, Ni 50Co 50) using two-temperature molecular dynamics simulations (2T-MD). The electronic heat conductivity in the two-temperature equations is parameterized from the results of first principles electronic structure calculations. A bismuth ion (1.542 GeV) is selected and single impact simulations performed inmore » each target. We study the heat flow in the electronic subsystem and show that alloying Ni with Co or Fe reduces the heat dissipation from the impact by the electronic subsystem. Simulation results suggest no melting or residual damage in pure Ni while a cylindrical region melts along the ion propagation path in the alloys. In Ni 50Co 50 the damage consists of a dislocation loop structure (d = 2 nm) and isolated point defects, while in Ni 50Fe 50, a defect cluster (d = 4 nm) along the ion path is, in addition, formed. The simulation results are supported by atomic-level structural and defect characterizations in bismuth-irradiated Ni and Ni 50Fe 50. Finally, the significance of the 2T-MD model is demonstrated by comparing the results to those obtained with an instantaneous energy deposition model without consideration of e-ph interactions in pure Ni and by showing that it leads to a different qualitative behavior.« less

  17. Jonathan W. Amy and the Amy Facility for Instrumentation Development.

    PubMed

    Cooks, R Graham

    2017-05-16

    This Perspective describes the unique Jonathan Amy Facility for Chemical Instrumentation in the Department of Chemistry at Purdue University, tracing its history and mode of operation. It also describes aspects of the career of its namesake and some of his insights which have been central to analytical instrumentation development, improvement, and utilization, both at Purdue and nationally.

  18. 32 CFR 21.400 - To what instruments does this subpart apply?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false To what instruments does this subpart apply? 21... AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Authorities and Responsibilities for Making and Administering Assistance Awards § 21.400 To what instruments does this subpart apply...

  19. 32 CFR 21.400 - To what instruments does this subpart apply?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false To what instruments does this subpart apply? 21... AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Authorities and Responsibilities for Making and Administering Assistance Awards § 21.400 To what instruments does this subpart apply...

  20. Heterobimetallic [NiFe] Complexes Containing Mixed CO/CN- Ligands: Analogs of the Active Site of the [NiFe] Hydrogenases.

    PubMed

    Perotto, Carlo U; Sodipo, Charlene L; Jones, Graham J; Tidey, Jeremiah P; Blake, Alexander J; Lewis, William; Davies, E Stephen; McMaster, Jonathan; Schröder, Martin

    2018-03-05

    The development of synthetic analogs of the active sites of [NiFe] hydrogenases remains challenging, and, in spite of the number of complexes featuring a [NiFe] center, those featuring CO and CN - ligands at the Fe center are under-represented. We report herein the synthesis of three bimetallic [NiFe] complexes [Ni( N 2 S 2 )Fe(CO) 2 (CN) 2 ], [Ni( S 4 )Fe(CO) 2 (CN) 2 ], and [Ni( N 2 S 3 )Fe(CO) 2 (CN) 2 ] that each contain a Ni center that bridges through two thiolato S donors to a {Fe(CO) 2 (CN) 2 } unit. X-ray crystallographic studies on [Ni( N 2 S 3 )Fe(CO) 2 (CN) 2 ], supported by DFT calculations, are consistent with a solid-state structure containing distinct molecules in the singlet ( S = 0) and triplet ( S = 1) states. Each cluster exhibits irreversible reduction processes between -1.45 and -1.67 V vs Fc + /Fc and [Ni( N 2 S 3 )Fe(CO) 2 (CN) 2 ] possesses a reversible oxidation process at 0.17 V vs Fc + /Fc. Spectroelectrochemical infrared (IR) and electron paramagnetic resonance (EPR) studies, supported by density functional theory (DFT) calculations, are consistent with a Ni III Fe II formulation for [Ni( N 2 S 3 )Fe(CO) 2 (CN) 2 ] + . The singly occupied molecular orbital (SOMO) in [Ni( N 2 S 3 )Fe(CO) 2 (CN) 2 ] + is based on Ni 3d z 2 and 3p S with the S contributions deriving principally from the apical S-donor. The nature of the SOMO corresponds to that proposed for the Ni-C state of the [NiFe] hydrogenases for which a Ni III Fe II formulation has also been proposed. A comparison of the experimental structures, and the electrochemical and spectroscopic properties of [Ni( N 2 S 3 )Fe(CO) 2 (CN) 2 ] and its [Ni( N 2 S 3 )] precursor, together with calculations on the oxidized [Ni( N 2 S 3 )Fe(CO) 2 (CN) 2 ] + and [Ni( N 2 S 3 )] + forms suggests that the binding of the {Fe(CO)(CN) 2 } unit to the {Ni(CysS) 4 } center at the active site of the [NiFe] hydrogenases suppresses thiolate-based oxidative chemistry involving the bridging thiolate S donors

  1. Transformation characteristics of TiNi/TiNi alloys synthesized by explosive welding

    NASA Astrophysics Data System (ADS)

    Li, Juntao; Zheng, Yanjun; Cui, Lishan

    2007-10-01

    Effects of severe deformation and heat treatment on the transformation behaviors of explosively welded duplex TiNi/TiNi shape memory alloys (SMAs) were investigated by the differential scanning calorimeter (DSC). The explosively welded duplex TiNi/TiNi plate of 0.7 mm in thickness was cold-rolled at room temperature to the extent of 60% reduction in thickness and then annealed at different temperatures (573-973 K) for different time (15 min-10 h). Low temperature (623-723 K) heat treatment led to amorphous crystallization. At higher temperature (873 K), the re-crystallization took place in the specimens. Analysis showed that the change of internal stresses is just the root cause of the change of transformation temperature. The relationships between the transformation behaviors and the heat treatment were discussed in the present report.

  2. Results of qualification tests on water-level sensing instruments, 1986

    USGS Publications Warehouse

    Holland, Randolph R.; Rapp, Donald H.

    1988-01-01

    This report presents to users of hydrological instrumentation and U.S. Geological Survey procurement personnel a list of instruments that have met or exceeded the Survey 's minimum performance requirements for water level sensing instruments. The Hydrologic Instrumentation Facility at the National Space Technology Laboratories, Mississippi conducted qualification tests on four instrument systems. The data collected are summarized, brief system descriptions are given, qualification testing purposes and procedures are summarized, and results are given for each of the three systems that met performance requirements. The fourth system was returned to the manufacturer , because in preliminary testing the instrument system did not perform properly according to the manufacturer 's operating procedures. As a result of the qualification tests, the three systems that met performance requirements have been included on the Survey 's Qualified Products List. (USGS)

  3. A mathematical model for describing the mechanical behaviour of root canal instruments.

    PubMed

    Zhang, E W; Cheung, G S P; Zheng, Y F

    2011-01-01

    The purpose of this study was to establish a general mathematical model for describing the mechanical behaviour of root canal instruments by combining a theoretical analytical approach with a numerical finite-element method. Mathematical formulas representing the longitudinal (taper, helical angle and pitch) and cross-sectional configurations and area, the bending and torsional inertia, the curvature of the boundary point and the (geometry of) loading condition were derived. Torsional and bending stresses and the resultant deformation were expressed mathematically as a function of these geometric parameters, modulus of elasticity of the material and the applied load. As illustrations, three brands of NiTi endodontic files of different cross-sectional configurations (ProTaper, Hero 642, and Mani NRT) were analysed under pure torsion and pure bending situation by entering the model into a finite-element analysis package (ANSYS). Numerical results confirmed that mathematical models were a feasible method to analyse the mechanical properties and predict the stress and deformation for root canal instruments during root canal preparation. Mathematical and numerical model can be a suitable way to examine mechanical behaviours as a criterion of the instrument design and to predict the stress and strain experienced by the endodontic instruments during root canal preparation. © 2010 International Endodontic Journal.

  4. Structural features of [NiFeSe] and [NiFe] hydrogenases determining their different properties: a computational approach.

    PubMed

    Baltazar, Carla S A; Teixeira, Vitor H; Soares, Cláudio M

    2012-04-01

    Hydrogenases are metalloenzymes that catalyze the reversible reaction H(2)<->2H(+) + 2e(-), being potentially useful in H(2) production or oxidation. [NiFeSe] hydrogenases are a particularly interesting subgroup of the [NiFe] class that exhibit tolerance to O(2) inhibition and produce more H(2) than standard [NiFe] hydrogenases. However, the molecular determinants responsible for these properties remain unknown. Hydrophobic pathways for H(2) diffusion have been identified in [NiFe] hydrogenases, as have proton transfer pathways, but they have never been studied in [NiFeSe] hydrogenases. Our aim was, for the first time, to characterize the H(2) and proton pathways in a [NiFeSe] hydrogenase and compare them with those in a standard [NiFe] hydrogenase. We performed molecular dynamics simulations of H(2) diffusion in the [NiFeSe] hydrogenase from Desulfomicrobium baculatum and extended previous simulations of the [NiFe] hydrogenase from Desulfovibrio gigas (Teixeira et al. in Biophys J 91:2035-2045, 2006). The comparison showed that H(2) density near the active site is much higher in [NiFeSe] hydrogenase, which appears to have an alternative route for the access of H(2) to the active site. We have also determined a possible proton transfer pathway in the [NiFeSe] hydrogenase from D. baculatum using continuum electrostatics and Monte Carlo simulation and compared it with the proton pathway we found in the [NiFe] hydrogenase from D. gigas (Teixeira et al. in Proteins 70:1010-1022, 2008). The residues constituting both proton transfer pathways are considerably different, although in the same region of the protein. These results support the hypothesis that some of the special properties of [NiFeSe] hydrogenases could be related to differences in the H(2) and proton pathways. © SBIC 2012

  5. A dithiolate-bridged (CN)2(CO)Fe-Ni complex reproducing the IR bands of [NiFe] hydrogenase.

    PubMed

    Tanino, Soichiro; Li, Zilong; Ohki, Yasuhiro; Tatsumi, Kazuyuki

    2009-03-16

    A dithiolate-bridged dinuclear Fe-Ni complex, which has the desired fac-(CN)(2)(CO) ligand set at iron, has been synthesized. Its CN/CO bands in the IR spectrum reproduce those of the Ni-A, Ni-B, and Ni-SU states, which indicate that these octahedral Fe(II) centers have similar electronic properties. This result verifies the assignment of a (CN)(2)(CO)Fe(II) moiety in the active site of [NiFe] hydrogenase.

  6. Nickel recovery from electronic waste II electrodeposition of Ni and Ni-Fe alloys from diluted sulfate solutions.

    PubMed

    Robotin, B; Ispas, A; Coman, V; Bund, A; Ilea, P

    2013-11-01

    This study focuses on the electrodeposition of Ni and Ni-Fe alloys from synthetic solutions similar to those obtained by the dissolution of electron gun (an electrical component of cathode ray tubes) waste. The influence of various parameters (pH, electrolyte composition, Ni(2+)/Fe(2+) ratio, current density) on the electrodeposition process was investigated. Scanning electron microscopy (SEM) and X-ray fluorescence analysis (XRFA) were used to provide information about the obtained deposits' thickness, morphology, and elemental composition. By controlling the experimental parameters, the composition of the Ni-Fe alloys can be tailored towards specific applications. Complementarily, the differences in the nucleation mechanisms for Ni, Fe and Ni-Fe deposition from sulfate solutions have been evaluated and discussed using cyclic voltammetry and potential step chronoamperometry. The obtained results suggest a progressive nucleation mechanism for Ni, while for Fe and Ni-Fe, the obtained data points are best fitted to an instantaneous nucleation model. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Fe-Ni-bearing serpentines from the saprolite horizon of Caribbean Ni-laterite deposits: new insights from thermodynamic calculations

    NASA Astrophysics Data System (ADS)

    Villanova-de-Benavent, Cristina; Domènech, Cristina; Tauler, Esperança; Galí, Salvador; Tassara, Santiago; Proenza, Joaquín A.

    2017-10-01

    Fe-Ni-bearing serpentine from the saprolite horizon is the main Ni ores in hydrous silicate-type Ni laterites and formed by chemical weathering of partially serpentinized ultramafic rocks under tropical conditions. During lateritization, Mg, Si, and Ni are leached from the surface and transported downwards. Fe2+ is oxidized to Fe3+ and fixed as insoluble Fe-oxyhydroxides (mostly goethite) that incorporate Ni. This Ni is later leached from goethite and incorporated in secondary serpentine and garnierite. As a result, a serpentine-dominated saprolite horizon forms over the ultramafic protolith, overlapped by a Fe-oxyhydroxide-dominated limonite horizon. The serpentine from the protolith (serpentine I) is of hydrothermal origin and yields similar Ni (0.10-0.62 wt.% NiO) and lower Fe (mostly 1.37-5.81 wt.% FeO) concentrations than the primary olivine. In contrast, Fe-Ni-bearing serpentine from the saprolite (serpentine II) shows significantly higher and variable Fe and Ni contents, typically ranging from 2.23 to 15.59 wt.% Fe2O3 and from 1.30 to 7.67 wt.% NiO, suggesting that serpentine get enriched in Fe and Ni under supergene conditions. This study presents detailed mineralogical, textural, and chemical data on this serpentine II, as well as new insights by thermodynamic calculations assuming ideal solution between Fe-, Ni- and Mg-pure serpentines. The aim is to assess if at atmospheric pressure and temperature Fe-Ni-bearing serpentine can be formed by precipitation. Results indicate that the formation of serpentine II under atmospheric pressure and temperature is thermodynamically supported, and pH, Eh, and the equilibrium constant of the reaction are the parameters that affect the results more significantly.

  8. Effect of Thermal Treatments on Ni-Mn-Ga and Ni-Rich Ni-Ti-Hf/Zr High-Temperature Shape Memory Alloys

    NASA Astrophysics Data System (ADS)

    Santamarta, Ruben; Evirgen, Alper; Perez-Sierra, Aquilina M.; Pons, Jaume; Cesari, Eduard; Karaman, Ibrahim; Noebe, Ron D.

    2015-11-01

    Among all the promising high-temperature shape memory alloys (HTSMAs), the Ni-Mn-Ga and the Ni-Ti-Hf/Zr systems exhibit interesting shape memory and superelastic properties that may place them in a good position for potential applications. The present work shows that thermal treatments play a crucial role in controlling the martensitic phase transformation characteristics of both systems, but in different ways. On one hand, the equilibrium phase diagram of the Ni-Mn-Ga family allows selecting compositions with high transformation temperatures and outstanding thermal stability at relatively high temperatures in air, showing no significant changes in the transformation behavior for continuous aging up to ˜5 years at 500 °C. Moreover, the excellent thermal stability correlates with a good thermal cyclic stability and an exceptional oxidation resistance of the parent phase. On the other hand, precipitation processes controlled by thermal treatments are needed to manipulate the transformation temperatures, mechanical properties, and thermal stability of Ni-rich Ni-Ti-Hf/Zr alloys to become HTSMAs. These changes in the functional properties are a consequence of the competition between the mechanical and compositional effects of the precipitates on the martensitic transformation.

  9. Solution growth of NiO nanosheets supported on Ni foam as high-performance electrodes for supercapacitors

    PubMed Central

    2014-01-01

    Well-aligned nickel oxide (NiO) nanosheets with the thickness of a few nanometers supported on a flexible substrate (Ni foam) have been fabricated by a hydrothermal approach together with a post-annealing treatment. The three-dimensional NiO nanosheets were further used as electrode materials to fabricate supercapacitors, with high specific capacitance of 943.5, 791.2, 613.5, 480, and 457.5 F g-1 at current densities of 5, 10, 15, 20, and 25 A g-1, respectively. The NiO nanosheets combined well with the substrate. When the electrode material was bended, it can still retain 91.1% of the initial capacitance after 1,200 charging/discharging cycles. Compared with Co3O4 and NiO nanostructures, the specific capacitance of NiO nanosheets is much better. These characteristics suggest that NiO nanosheet electrodes are promising for energy storage application with high power demands. PMID:25276099

  10. Extreme April 2016 temperatures in Mainland Southeast Asia caused by El Niño and exacerbated by global warming

    NASA Astrophysics Data System (ADS)

    Thirumalai, K.; Di Nezio, P. N.; Okumura, Y.; Deser, C.

    2016-12-01

    In April 2016, Mainland Southeast Asia (MSA) experienced monthly mean surface air temperatures (SATs) that surpassed national records, caused widespread discomfort, and greatly exacerbated energy consumption. First, we reveal a robust relationship between the El Niño Southern Oscillation (ENSO) and April SATs in the region, demonstrating that virtually all extreme, hot Aprils occur during El Niño years. Next, we show that MSA has experienced continuous warming since the early 20th century. To quantify the relative contributions of this long-term warming trend and the 2015 El Niño to the extreme April 2016 SATs, we use observations and a large ensemble of global warming simulations, performed with a model that realistically simulates this El-Niño-MSA link. We find robust evidence that the "post-Niño" hot Aprils are being exacerbated by global warming, with this effect being pronounced for the 2016 event, where we estimate 24% was caused by warming and 49% by El Niño. Despite an increased likelihood of hot Aprils during El Niño years in the future, our findings suggest that these extremes can potentially be anticipated a few months in advance.

  11. Gyroscopic Instruments for Instrument Flying

    NASA Technical Reports Server (NTRS)

    Brombacher, W G; Trent, W C

    1938-01-01

    The gyroscopic instruments commonly used in instrument flying in the United States are the turn indicator, the directional gyro, the gyromagnetic compass, the gyroscopic horizon, and the automatic pilot. These instruments are described. Performance data and the method of testing in the laboratory are given for the turn indicator, the directional gyro, and the gyroscopic horizon. Apparatus for driving the instruments is discussed.

  12. Climate Prediction Center - El Niño/La Niña Home

    Science.gov Websites

    Composites Cold and Warm episodes (by season) U.S. La Niña Precipitation & Temperature Impacts U.S. El Niño Precipitation & Temperature Impacts U.S. El Niño State Seasonal Precipitation & ; Temperature Impacts Expert Assessment Current Diagnostic Discussion Monitoring & Data Weekly UpdateFigures

  13. Bone Cell–materials Interactions and Ni Ion Release of Anodized Equiatomic NiTi Alloy

    PubMed Central

    Bernard, Sheldon A.; Balla, Vamsi Krishna; Davies, Neal M.; Bose, Susmita; Bandyopadhyay, Amit

    2011-01-01

    Laser processed NiTi alloy was anodized for different durations in H2SO4 electrolyte with varying pH to create biocompatible surfaces with low Ni ion release as well as bioactive surfaces to enhance biocompatibility and bone cell-materials interactions. The anodized surfaces were assessed for their in vitro cell-materials interactions using human fetal osteoblast (hFOB) cells for 3, 7 and 11 days, and Ni ion release up to 8 weeks in simulated body fluids. The results were correlated with surface morphologies of anodized surfaces characterized using field-emission scanning electron microscopy (FESEM). The results show that the anodization creates a surface with nano/micro roughness depending on anodization conditions. The hydrophilicity of NiTi surface was found to improve after anodization due to lower contact angles in cell media, which dropped from 32° to < 5°. The improved wettability of anodized surfaces is further corroborated by their high surface energy comparable to that of cp Ti. Relatively high surface energy, especially polar component, and nano/micro surface features of anodized surfaces significantly increased the number of living cells and their adherence and growth on these surfaces. Finally, a significant drop in Ni ion release from 268 ± 11 to 136 ± 15 ppb was observed for NiTi surfaces after anodization. This work indicates that anodization of NiTi alloy has a positive influence on the surface energy and surface morphology, which in turn improve bone cell-materials interactions and reduce Ni ion release in vitro. PMID:21232641

  14. Wyoming Cloud Lidar: instrument description and applications.

    PubMed

    Wang, Zhien; Wechsler, Perry; Kuestner, William; French, Jeffrey; Rodi, Alfred; Glover, Brent; Burkhart, Matthew; Lukens, Donal

    2009-08-03

    The Wyoming Cloud Lidar (WCL), a compact two-channel elastic lidar, was designed to obtain cloud measurements together with the Wyoming Cloud Radar (WCR) on the University of Wyoming King Air and the National Science Foundation/National Center of Atmospheric Research C-130 aircraft. The WCL has been deployed in four field projects under a variety of atmospheric and cloud conditions during the last two years. Throughout these campaigns, it has exhibited the needed reliability for turn-key operation from aircraft. We provide here an overview of the instrument and examples to illustrate the measurements capability of the WCL. Although the WCL as a standalone instrument can provide unique measurements for cloud and boundary layer aerosol studies, the synergy of WCL and WCR measurements coupled with in situ sampling from an aircraft provide a significant step forward in our ability to observe and understand cloud microphysical property evolution.

  15. Effect of heat treatment on morphology evolution of Ti2Ni phase in Ti-Ni-Al-Zr alloy

    NASA Astrophysics Data System (ADS)

    Sheng, Liyuan; Yang, Yang; Xi, Tingfei

    2018-03-01

    The Ti6Al2Zr alloy with 15 wt.% Ni addition was prepared and then heat treated in the research. The microstructure of the alloy and evolution of Ti2Ni precipitate were investigated. The microstructure observations demonstrate that the Ni addition could promote the formation of eutectoid and eutectic structures in Ti-Al-Zr alloy. In the eutectoid structure, the ultrafine Ti2Ni fiber precipitates in the α-Ti matrix, but in the eutectic structure, the fine α-Ti phases precipitate in the Ti2Ni matrix. The heat treatment could change the morphology of Ti2Ni precipitates by thinning, fragmenting, merging and spherizing. In the alloy heat treated at and below 1073K, the coarsening of α-Ti precipitates in eutectic structure and Ti2Ni precipitates in eutectoid structure is the mainly characteristic. In the alloy heat treated above 1073K, the phase transformation of α to β phase is the main characteristic, which changes the morphology and amount of Ti2Ni phase by the solid solution of Ni. The phase transformation temperature of Ti-Ni-Al-Zr alloy is between 1073-1123K, which is increased compared with that of the Ti-Ni binary phase diagram.

  16. The Effects of Torsional Preloading on the Torsional Resistance of Nickel-titanium Instruments.

    PubMed

    Oh, Seung-Hei; Ha, Jung-Hong; Kwak, Sang Won; Ahn, Shin Wook; Lee, WooCheol; Kim, Hyeon-Cheol

    2017-01-01

    This study evaluated the effect of torsional preloading on the torsional resistance of nickel-titanium (NiTi) endodontic instruments. WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) and ProTaper Universal F2 (Dentsply Maillefer) files were used. The ultimate torsional strength until fracture was determined for each instrument. In the phase 1 experiment, the ProTaper and WaveOne files were loaded to have a maximum load from 2.0 up to 2.7 or 2.8 Ncm, respectively. In the phase 2 experiment, the number of repetitions of preloading for each file was increased from 50 to 200, whereas the preloading torque was fixed at 2.4 Ncm. Using torsionally preloaded specimens from phase 1 and 2, the torsional resistances were calculated to determine the ultimate strength, distortion angle, and toughness. The results were analyzed using 1-way analysis of variance and Duncan post hoc comparison. The fracture surfaces and longitudinal aspect of 5 specimens per group were examined under a scanning electron microscope. All preloaded groups showed significantly higher ultimate strength than the unpreloaded groups (P < .05). There was no significant difference among all groups for distortion angle and toughness. Although WaveOne had no significant difference between the repetition groups for ultimate strength, fracture angle, and toughness, ProTaper had a higher distortion angle and toughness in the 50-repetition group compared with the other repetition groups (P < .05). Scanning electron microscopic examinations of the fractured surface showed typical features of torsional fracture. Torsional preloading within the ultimate values could enhance the torsional strength of NiTi instruments. The total energy until fracture was maintained constantly, regardless of the alloy type. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Electronic circuits having NiAl and Ni.sub.3 Al substrates

    DOEpatents

    Deevi, Seetharama C.; Sikka, Vinod K.

    1999-01-01

    An electronic circuit component having improved mechanical properties and thermal conductivity comprises NiAl and/or Ni.sub.3 Al, upon which an alumina layer is formed prior to applying the conductive elements. Additional layers of copper-aluminum alloy or copper further improve mechanical strength and thermal conductivity.

  18. Constitution of the Sr-Ni-O system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zinkevich, M.

    2005-09-15

    The constitution of the Sr-Ni-O system was studied experimentally for the first time. Samples were prepared either from SrCO{sub 3} and NiO or from Sr(NO{sub 3}){sub 2} and Ni(NO{sub 3}){sub 2}.6H{sub 2}O and characterized by high-temperature X-ray powder diffraction, scanning electron microscopy, thermogravimetric and differential thermal analyses. In the SrO-NiO quasibinary system an eutectic reaction: liquid-bar SrO+NiO was found to occur at 1396+/-5{sup o}C, while the homogeneity range of terminal solid solutions is negligible. Thermodynamic calculations using the regular solution model for the liquid and rocksalt-type phases were employed to predict liquidus and solidus curves. Three ternary compounds, SrNiO{sub 2.5},more » Sr{sub 5}Ni{sub 4}O{sub 11}, and Sr{sub 9}Ni{sub 7}O{sub 21} were observed in the samples prepared from nitrate solutions, but only Sr{sub 9}Ni{sub 7}O{sub 21} was proved to be thermodynamically stable in air up to 1030+/-6{sup o}C. When heating in air, SrNiO{sub 2.5} and Sr{sub 5}Ni{sub 4}O{sub 11} were found to transform irreversibly into a mixture of Sr{sub 9}Ni{sub 7}O{sub 21} and NiO. Isothermal section of the SrO-NiO-O subsystem, which represents phase equilibria at 950-1030{sup o}C as well as an isobaric section of the Sr-Ni-O system in air were constructed.« less

  19. The fabrication of foam-like 3D mesoporous NiO-Ni as anode for high performance Li-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Peng, E-mail: huangp07@lzu.edu.cn; Department of Physics, Lanzhou University, Lanzhou 730000; Zhang, Xin

    2015-03-15

    Graphical abstract: Foam-like 3 dimensional (3D) mesoporous NiO on 3D micro-porous Ni was fabricated. - Highlights: • We prepare NiO-Ni foam composite via hydrothermal etching and subsequent annealing. • The NiO exhibits novel foam-like 3D mesoporous architecture. • The NiO-Ni anode shows good cycle stability. - Abstract: Foam-like three dimensional mesoporous NiO on Ni foam was fabricated via facile hydrothermal etching and subsequent annealing treatment. The porous NiO consists of a large number of nanosheets with mean thickness about 50 nm, among which a large number of mesoscopic pores with size ranges from 100 nm to 1 μm distribute. Themore » electrochemical performance of the as-prepared NiO-Ni as anode for lithium ion battery was studied by conventional charge/discharge test, which shows excellent cycle stability and rate capability. It exhibits initial discharge and charge capacities of 979 and 707 mA h g{sup −1} at a charge/discharge rate of 0.7 C, which maintain of 747 and 738 mA h g{sup −1} after 100 cycles. Even after 60 cycles at various rates from 0.06 to 14 C, the 10th discharge and charge capacities of the NiO-Ni electrode can revert to 699 and 683 mA h g{sup −1} when lowering the charge/discharge rate to 0.06 C.« less

  20. 32 CFR 644.411 - Form of inter-agency transfer instrument.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Form of inter-agency transfer instrument. 644.411 Section 644.411 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY... for signature of the Secretary of the transferring department and will be addressed to the Secretary...

  1. Ni-MH spent batteries: a raw material to produce Ni-Co alloys.

    PubMed

    Lupi, Carla; Pilone, Daniela

    2002-01-01

    Ni-MH spent batteries are heterogeneous and complex materials, so any kind of metallurgical recovery process needs a mechanical pre-treatment at least to separate irony materials and recyclable plastic materials (like ABS) respectively, in order to get additional profit from this saleable scrap, as well as minimize waste arising from the braking separation process. Pyrometallurgical processing is not suitable to treat Ni-MH batteries mainly because of Rare Earths losses in the slag. On the other hand, the hydrometallurgical method, that offers better opportunities in terms of recovery yield and higher purity of Ni, Co, and RE, requires several process steps as shown in technical literature. The main problems during leach liquor purification are the removal of elements such as Mn, Zn, Cd, dissolved during the leaching step, and the separation of Ni from Co. In the present work, the latter problem is overcome by co-deposition of a Ni-35/40%w Co alloy of good quality. The experiments carried out in a laboratory scale pilot-plant show that a current efficiency higher than 91% can be reached in long duration electrowinning tests performed at 50 degrees C and 4.3 catholyte pH.

  2. Synthesis, characterization and some properties of mononuclear Ni and trinuclear NiFe2 complexes related to the active site of [NiFe]-hydrogenases.

    PubMed

    Song, Li-Cheng; Sun, Xiao-Jing; Zhao, Pei-Hua; Li, Jia-Peng; Song, Hai-Bin

    2012-08-07

    The [N(2)S(2)]-type ligand 1,2-(2-C(5)H(4)NCH(2)S)(2)C(6)H(4) (L) is prepared in 84% yield by a new method and its structure has been confirmed by X-ray crystallography. The new synthetic method involves sequential reaction of 1,2-phenylenedithiol with EtONa followed by treatment of the resulting disodium salt of 1,2-phenylenedithiol with in situ generated 2-(chloromethyl)pyridine from its HCl salt. Further treatment of ligand L with NiCl(2)·6H(2)O or NiI(2) affords the expected new mononuclear Ni complexes Ni[1,2-(2-C(5)H(4)NCH(2)S)(2)C(6)H(4)]Cl(2) (1) and Ni[1,2-(2-C(5)H(4)NCH(2)S)(2)C(6)H(4)]I(2) (3) in 87-88% yields, whereas reaction of L with NiBr(2) under similar conditions results in formation of the expected new mononuclear complex Ni[1,2-(2-C(5)H(4)NCH(2)S)(2)C(6)H(4)]Br(2) (2) and one unexpected new mononuclear complex Ni[1-(2-C(5)H(4)NCH(2)S)-2-(2-C(5)H(4)NCH(2)SC(6)H(4)S)C(6)H(4)]Br(2) (2*) in 82% and 5% yields, respectively. More interestingly, the ligand L-containing novel trinuclear NiFe(2) complex Ni{[1,2-(2-C(5)H(4)NCH(2)S)(2)C(6)H(4)}Fe(2)(CO)(6)(μ(3)-S)(2) (4) is found to be prepared by sequential reaction of (μ-S(2))Fe(2)(CO)(6) with Et(3)BHLi, followed by treatment of the resulting (μ-LiS)(2)Fe(2)(CO)(6) with mononuclear complex 1, 2, or 3 in 12-20% yields. The new complexes 1-4 and 2* are fully characterized by elemental analysis and various spectroscopies, and the crystal structures of 1, 2* and 3 as well as some electrochemical properties of 1-4 are also reported.

  3. Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

    PubMed

    Gambarini, Gianluca; Giansiracusa Rubini, Alessio; Sannino, Giampaolo; Di Giorgio, Gianni; Di Giorgio, Fabrizio; Piasecki, Lucila; Al-Sudani, Dina; Plotino, Gianluca; Testarelli, Luca

    2016-01-01

    The aim of the present study was to compare the cutting efficiency of Twisted File instruments used in continuous rotation or TF Adaptive motion and evaluate if prolonged use significantly affected their cutting ability. 20 new NiTi instruments were used in the present study (TF tip size 35, 0.06 taper; Sybron-Endo, Orange, CA, USA), divided into 2 subgroups of 10 instruments each, depending on which movement was selected on the endodontic motor. Group 1: TF instruments were activated using the program TF continuous rotation at 500 rpm and torque set at 2 N; Group 2: TF instruments were activated using the reciprocating TF Adaptive motion. Cutting efficiency was tested in a device developed to test the cutting ability of endodontic instruments. Each instrument cut 10 plastic blocks (10 uses) and the length of the surface cut in a plastic block after 1 min was measured in a computerized program with a precision of 0.1 mm. Maximum penetration depth was calculated after 1 use and after 10 uses, and mean and standard deviation (SD) of each group was calculated. Data were statistically analyzed with a one-way ANOVA test (P < 0.05). TF instruments used in continuous rotation (Group 1) cut a mean depth of 10.4 mm (SD = 0.6 mm) after the first use and 10.1 mm (SD 1.1 mm) after 10 uses, while TF instruments used with the Adaptive motion cut a mean depth of 9.9 mm (SD = 0.7 mm) after the first use and 9.6 mm (SD = 0.9 mm) after 10 uses. There was no statistically significant difference between the two groups investigated (P > 0.05) nor between instruments after 1 or 10 uses. In conclusion, the TFA motion showed a lateral cutting ability similar to continuous rotation and all tested instruments exhibited the same cutting ability after prolonged use.

  4. Radiation damage buildup and dislocation evolution in Ni and equiatomic multicomponent Ni-based alloys

    NASA Astrophysics Data System (ADS)

    Levo, E.; Granberg, F.; Fridlund, C.; Nordlund, K.; Djurabekova, F.

    2017-07-01

    Single-phase multicomponent alloys of equal atomic concentrations ("equiatomic") have proven to exhibit promising mechanical and corrosion resistance properties, that are sought after in materials intended for use in hazardous environments like next-generation nuclear reactors. In this article, we investigate the damage production and dislocation mobility by simulating irradiation of elemental Ni and the alloys NiCo, NiCoCr, NiCoFe and NiFe, to assess the effect of elemental composition. We compare the defect production and the evolution of dislocation networks in the simulation cells of two different sizes, for all five studied materials. We find that the trends in defect evolution are in good agreement between the different cell sizes. The damage is generally reduced with increased alloy complexity, and the dislocation evolution is specific to each material, depending on its complexity. We show that increasing complexity of the alloys does not always lead to decreased susceptibility to damage accumulation under irradiation. We show that, for instance, the NiCo alloy behaves very similarly to Ni, while presence of Fe or Cr in the alloy even as a third component reduces the saturated level of damage substantially. Moreover, we linked the defect evolution with the dislocation transformations in the alloys. Sudden drops in defect number and large defect fluctuations from the continuous irradiation can be explained from the dislocation activity.

  5. One-pot fabrication of NiFe2O4 nanoparticles on α-Ni(OH)2 nanosheet for enhanced water oxidation

    NASA Astrophysics Data System (ADS)

    Chen, Hong; Yan, Junqing; Wu, Huan; Zhang, Yunxia; Liu, Shengzhong (Frank)

    2016-08-01

    Water splitting has been intensively investigated as a promising solution to resolve the future environmental and energy crises. The oxygen evolution reaction (OER) of the photo- and electric field-induced water splitting limits the development of other reactions, including hydrogen evolution reaction (HER). Fe, Ni and NiFe (hydro) oxide-based catalysts are generally acknowledged among the best candidates of OER catalysts for water splitting. Herein, we developed a one-pot simple hydrothermal process to assemble NiFe2O4 nanoparticles onto the α-Ni(OH)2 nanosheets. The first formed NiFe2O4 under high temperature and pressure environment induces and assists the α-Ni(OH)2 formation without any further additives, because the distance between the neighboring Ni atoms in the cubic NiFe2O4 is similar to that in the α-Ni(OH)2 {003} facets. We have synthesized a series of NiFe2O4/α-Ni(OH)2 compounds and find that the overpotential decreases with the increase of Ni(OH)2 content while the OER kinetics stays unchanged, suggesting that Ni(OH)2 plays a major role in overpotential while NiFe2O4 mainly affects the OER kinetics. The obtained NiFe2O4/α-Ni(OH)2 compounds is also found to be a promising co-catalyst for the photocatalytic water oxidation. In fact, it is even more active than the noble PtOx with acceptable stability for the oxygen generation.

  6. Electromigration effect upon the Sn-0.7 wt% Cu/Ni and Sn-3.5 wt% Ag/Ni interfacial reactions

    NASA Astrophysics Data System (ADS)

    Chen, Chih-ming; Chen, Sinn-wen

    2001-08-01

    This study investigates the effect of electromigration upon the interfacial reactions between the promising lead-free solders, Sn-Cu and Sn-Ag, with Ni substrate. Sandwich-type reaction couples, Sn-0.7 wt% Cu/Ni/Sn-0.7 wt% Cu and Sn-3.5 wt% Ag/Ni/Sn-3.5 wt% Ag, were reacted at 160, 180, and 200 °C for various lengths of time with and without the passage of electric currents. Without passage of electric currents through the couples, only one intermetallic compound Ni3Sn4 with ˜7 at. % Cu solubility was found at both interfaces of the Sn-0.7 wt% Cu/Ni couples. With the passage of an electric current of 500 A/cm2 density, the Cu6Sn5 phase was formed at the solder/Ni interface besides the Ni3Sn4 phase. Similar to those without the passage of electric currents, only the Ni3Sn4 phase was found at the Ni/solder interface. Directions of movement of electrons, Sn, and Cu atoms are the same at the solder/Ni interface, and the growth rates of the intermetallic layers were enhanced. At the Ni/solder interface, the electrons flow in the opposite direction of the Sn and Cu movement, and the growth rates of the intermetallic layers were retarded. Only the Ni3Sn4 phase was formed from the Sn-3.5 wt% Ag/Ni interfacial reaction with and without the passage of electric currents. Similar to the Sn-0.7 wt% Cu/Ni system, the movement of electrons enhances or retards the growth rates of the intermetallic layers at the solder/Ni and Ni/solder interfaces, respectively. Calculation results show the apparent effective charge za* decreases in magnitude with raising temperatures, which indicates the electromigration effect becomes insignificant at higher temperatures.

  7. 3D Computer Models of T- x- y Diagrams, Forming the Fe-Ni-Co-FeS-NiS-CoS Subsystem

    NASA Astrophysics Data System (ADS)

    Lutsyk, V. I.; Vorob'eva, V. P.

    2017-12-01

    3D computer models of Fe-Ni-Co, Fe-Ni-FeS-NiS, Fe-Co-FeS-CoS, Ni-Co-NiS-CoS T- x- y diagrams have been designed. The geometric structure (35 surfaces, two-phase surface of the reaction type change, 17 phase regions) of the Fe-Ni-FeS-NiS T- x- y diagram is investigated in detail. The liquidus hypersurfaces prediction of the Fe-Ni-Co-FeS-NiS-CoS subsystem is represented.

  8. Template-Mediated Ni(II) Dispersion in Mesoporous SiO2 for Preparation of Highly Dispersed Ni Catalysts: Influence of Template Type.

    PubMed

    Ning, Xin; Lu, Yiyuan; Fu, Heyun; Wan, Haiqin; Xu, Zhaoyi; Zheng, Shourong

    2017-06-07

    Supported Ni catalysts on three mesoporous SiO 2 supports (i.e., SBA-15, MCM-41, and HMS) were prepared using a solid-state reaction between Ni(NO 3 ) 2 and organic template-occluded mesoporous SiO 2 . For comparison, supported Ni catalysts on mesoporous SiO 2 synthesized by the conventional impregnation method were also included. The catalysts were characterized by scanning electron microscopy, X-ray diffraction, UV-vis diffuse reflectance spectroscopy, N 2 adsorption, X-ray photoelectron spectroscopy, H 2 temperature-programmed reduction, transmission electron microscopy, and transmission electron microscopy-energy-dispersive X-ray. The catalytic properties of the catalysts were evaluated using gas-phase catalytic hydrodechlorination of 1,2-dichloroethane. The results showed that upon grinding Ni(NO 3 ) 2 with template-occluded mesoporous SiO 2 , strong coordination between Ni 2+ and dodecylamine was identified in the Ni(NO 3 ) 2 -HMS system. Additionally, the results of H 2 temperature-programmed reduction revealed that NiO in calcined NiO/HMS was reduced at higher temperature than those in calcined NiO/SBA-15 and NiO/MCM-41, reflecting the presence of a strong interaction between NiO and mesoporous SiO 2 in NiO/HMS. Consistently, the average particle sizes of metallic Ni were found to be 2.7, 3.4, and 9.6 nm in H 2 -reduced Ni/HMS, Ni/SBA-15, and Ni/MCM-41, respectively, indicative of a much higher Ni dispersion in Ni/HMS. For the catalytic hydrodechlorination of 1,2-dichloroethane, Ni/MCM-41 synthesized by the solid-state reaction method exhibited a catalytic activity similar to that prepared by the impregnation method, while higher catalytic activities were observed on Ni/HMS and Ni/SBA-15 than on their counterparts prepared by the impregnation method. Furthermore, a higher conversion was identified on Ni/HMS than on Ni/SBA-15 and Ni/MCM-41, highlighting the importance of template type for the preparation of highly dispersed metal catalysts on mesoporous Si

  9. Capture of Hydrogen Using ZrNi

    NASA Technical Reports Server (NTRS)

    Patton, Lisa; Wales, Joshua; Lynch, David; Parrish, Clyde

    2005-01-01

    Water, as ice, is thought to reside in craters at the lunar poles along with CH4 and H2 . A proposed robotic mission for 2012 will utilize metal/metal hydrides for H2 recovery. Specifications are 99% capture of H2 initially at 5 bar and 100C (or greater), and degassing completely at 300C. Of 47-systems examined using the van't Hoff equation, 4 systems, Mg/MgH2, Mg2Ni/Mg2NiH4, ZrNi/ZrNiH2.8, and Pd/PdH0.77, were considered likely candidates for further examination. It is essential, when selecting a system, to also examine questions regarding activation, kinetics, cyclic stability, and gas impurity effects. After considering those issues, ZrN1 was selected as the most promising candidate, as it is easily activated and rapidly forms ZrNiH 2.8 . In addition, it resists oxide poisoning by CO2, and H2O, while some oxidation by O2 is recommended for improved activation . The presence of hydrogen in the as received Zr-Ni alloy from Alfa Aesar posed additional technical problems. X-ray diffraction of the Zr-Ni powder (-325 mesh), with a Zr:Ni wt% ratio of 70:30, was found to consist of ZrH2, ZrNiH2.8, and ZrNi. ZrH2 in the alloy presented the risk that after degassing that both Zr and ZrNi would be present, and thus lead to erroneous results regarding the reactivity of ZrNi with H2 . Fortunately, ZrH2 is a highly stable hydride that does not degas H2 to any significant extent at temperatures below 300C. Based on equilibrium calculations for the decomposition of ZrH2, only 1 millionth of the hydride decomposed at 300C under a N2 atmosphere flowing at 25 ccm for 64 hours, the longest time for pretreatment employed in the investigation. It was possible, from the X-ray results and knowledge of the Zr:Ni ratio, to compute the composition of a pretreated specimen as being 76 wt% ZrNi and the balance ZrH2.

  10. The crystal structures of Ni{sub 3+x}Sn{sub 4}Zn and Ni{sub 6+x}Sn{sub 8}Zn and their structural relations to Ni{sub 3+x}Sn{sub 4}, NiSn and Ni{sub 5−δ}ZnSn{sub 4}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmetterer, Clemens, E-mail: clemens.schmetterer@univie.ac.at; Effenberger, Herta Silvia; Rajamohan, Divakar

    2016-06-15

    The crystal structures of two new compounds were determined from single-crystal X-ray diffraction measurements: Ni{sub 3+x}Sn{sub 4}Zn, (x~1.35, a=7.110(2) Å, b=4.123(1) Å, c=10.346(3) Å, β=90.23(2)°, space group I2/m, Z=2. R1=0.025, wR2=0.059 for 748 unique reflections, 35 variable parameters) and Ni{sub 6+x}Sn{sub 8}Zn, x~1.35 (a=12.379(3) Å, b=4.095(1) Å, c=12.155(3) Å, β=116.25(3)°, space group C2/m, Z=2. R1=0.026, wR2=0.052 for 1346 unique reflections, 60 variable parameters). In addition, a structural refinement was performed for Ni{sub 3+x}Sn{sub 4}, x~0.13 (a=12.264(3) Å, b=4.066(1) Å, c=5.223(2) Å, β=104.85(3)°, space group C2/m, Z=2. R1=0.019, wR2=0.046 for 617 unique reflections, 29 variable parameters). The three compounds show pronouncedmore » similarities among each other as well as to the crystal structures of surrounding binary Ni–Sn and ternary Ni–Sn–Zn compounds. In particular, the two new compounds form a homologous series with Ni{sub 3+x}Sn{sub 4}, x~0.13. They contain “Ni{sub 4}Sn{sub 4}” and “Ni{sub 2}Sn{sub 4}” building blocks which by different interconnection build up the distinct structures. Topological relations with NiSn and Ni{sub 5−δ}Sn{sub 4}Zn, δ~0.25 are evident. - Graphical abstract: Projection of the structure of Ni{sub 6+x}ZnSn{sub 8}, x~1.35 and constituent building blocks. Display Omitted - Highlights: • The crystal structures of Ni{sub 6+x}Sn{sub 8}Zn and Ni{sub 3+x}Sn{sub 4}Zn were determined using single crystal XRD. • Topological relations to Ni–Sn and Ni–Sn–Zn compounds were established and discussed. • Common structural units were identified and their interconnection patterns described.« less

  11. Selective oxidation of cube textured Ni and Ni-Cr substrate for the formation of cube textured NiO as a component buffer layer for REBa 2Cu 3O 7+ x (REBCO) coated conductors

    NASA Astrophysics Data System (ADS)

    Lockman, Z.; Goldacker, W.; Nast, R.; deBoer, B.; MacManus-Driscoll, J. L.

    2002-08-01

    Thermal oxidation of cube textured, pure Ni and Ni-Cr tapes was undertaken under different oxidation conditions to form cube textured NiO for the use as a first component of buffer layer for the coated conductor. Cube textured NiO was formed on pure Ni after oxidising for more than 130 min in O 2 at 1250 °C. The oxide thickness was >30 μm. Much shorter oxidation times (20-40 min, NiO thickness of ∼5 μm) and lower temperature (1050 °C) were required to form a similar texture on Ni-Cr foils. In addition, NiO formed on Ni-13%Cr was more highly textured than Ni-10%Cr. A Cr 2O 3 inner layer and NiO outer layer was formed on the Ni-Cr alloys.

  12. Synergetic interface between NiO/Ni3S2 nanosheets and carbon nanofiber as binder-free anode for highly reversible lithium storage

    NASA Astrophysics Data System (ADS)

    Jiang, Jialin; Ma, Chao; Yang, Yinbo; Ding, Jingjing; Ji, Hongmei; Shi, Shaojun; Yang, Gang

    2018-05-01

    A novel heterostructure of NiO/Ni3S2 nanoflake is synthesized and composited with carbon nanofibers (CNF) membrane. NiO/Ni3S2 nanoflakes are homogeneously dispersed in CNF network, herein, NiO/Ni3S2 like leaf and CNF like branch. Carbon nanofibers network efficiently prevents the pulverization and buffers the volume changes of NiO/Ni3S2, meanwhile, NiO/Ni3S2 nanoflakes through the conductive channels of carbon nanofibers own improved Li+ diffusion ability and structural stability. The capacity of NiO/Ni3S2/CNF reaches to 519.2 mA g-1 after 200 cycles at the current density of 0.5 A g-1 while NiO/Ni3S2 fades to 71 mAh g-1 after 40 cycles. Owing to the synergetic structure, the resultant binder-free electrode NiO/Ni3S2/carbon nanofibers shows an excellent reversible lithium storage capability.

  13. Instrumentation Cables Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muna, Alice Baca; LaFleur, Chris Bensdotter

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteriamore » 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended

  14. Rationally-designed configuration of directly-coated Ni 3S 2/Ni electrode by RGO providing superior sodium storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Xiaosheng; Li, Xifei; Bai, Zhimin

    Designing nanocomposite materials is an effective approach for enhancing the performance of sodium-ion batteries (SIBs), and understanding the synergy among components is critically important for new, better materials design. Here in this paper, a directly reduced graphene oxide (RGO) decorated anode electrode was designed and tested for SIBs, in which uniform RGO coating onto the Ni 3S 2/Ni electrode was realized using facile hydrothermal reactions. The results indicate that the RGO/Ni 3S 2/Ni electrode delivers a high reversible specific capacity of 448.6 mAh g -1, high capacity retention of 96.5% after 100 cycles, and excellent rate capability of 263.1 mAhmore » g -1 at 800 mA g -1. Compared with the Ni 3S 2/Ni electrode, the improved performance of the RGO/Ni 3S 2/Ni electrode benefits from RGO-promoted displacement reaction of Ni 3S 2 with sodium. DFT calculations reveal that the RGO layer can significantly improve the electron mobility of the RGO/Ni 3S 2 + Na structure, and the hybrid interaction between the extraneous p orbits of C and indigenous p and d orbits of Ni, as well as p orbits of S is the major reason for why RGO can improve the electrical transport properties.« less

  15. Rationally-designed configuration of directly-coated Ni 3S 2/Ni electrode by RGO providing superior sodium storage

    DOE PAGES

    Song, Xiaosheng; Li, Xifei; Bai, Zhimin; ...

    2018-02-28

    Designing nanocomposite materials is an effective approach for enhancing the performance of sodium-ion batteries (SIBs), and understanding the synergy among components is critically important for new, better materials design. Here in this paper, a directly reduced graphene oxide (RGO) decorated anode electrode was designed and tested for SIBs, in which uniform RGO coating onto the Ni 3S 2/Ni electrode was realized using facile hydrothermal reactions. The results indicate that the RGO/Ni 3S 2/Ni electrode delivers a high reversible specific capacity of 448.6 mAh g -1, high capacity retention of 96.5% after 100 cycles, and excellent rate capability of 263.1 mAhmore » g -1 at 800 mA g -1. Compared with the Ni 3S 2/Ni electrode, the improved performance of the RGO/Ni 3S 2/Ni electrode benefits from RGO-promoted displacement reaction of Ni 3S 2 with sodium. DFT calculations reveal that the RGO layer can significantly improve the electron mobility of the RGO/Ni 3S 2 + Na structure, and the hybrid interaction between the extraneous p orbits of C and indigenous p and d orbits of Ni, as well as p orbits of S is the major reason for why RGO can improve the electrical transport properties.« less

  16. Reading Instruments: Objects, Texts and Museums

    NASA Astrophysics Data System (ADS)

    Anderson, Katharine; Frappier, Mélanie; Neswald, Elizabeth; Trim, Henry

    2013-05-01

    Science educators, historians of science and their students often share a curiosity about historical instruments as a tangible link between past and present practices in the sciences. We less often integrate instruments into our research and pedagogy, considering artefact study as the domain of museum specialists. We argue here that scholars and teachers new to material culture can readily use artefacts to reveal rich and complex networks of narratives. We illustrate this point by describing our own lay encounter with an artefact turned over for our analysis during a week-long workshop at the Canada Science and Technology Museum. The text explains how elements as disparate as the military appearance of the instrument, the crest stamped on its body, the manipulation of its telescopes, or a luggage tag revealed the object's scientific and political significance in different national contexts. In this way, the presence of the instrument in the classroom vividly conveyed the nature of geophysics as a field practice and an international science, and illuminated relationships between pure and applied science for early twentieth century geologists. We conclude that artefact study can be an unexpectedly powerful and accessible tool in the study of science, making visible the connections between past and present, laboratory and field, texts and instruments.

  17. Bone cell-materials interactions and Ni ion release of anodized equiatomic NiTi alloy.

    PubMed

    Bernard, Sheldon A; Balla, Vamsi Krishna; Davies, Neal M; Bose, Susmita; Bandyopadhyay, Amit

    2011-04-01

    A laser processed NiTi alloy was anodized for different times in H(2)SO(4) electrolyte with varying pH to create biocompatible surfaces with low Ni ion release as well as bioactive surfaces to enhance biocompatibility and bone cell-material interactions. The anodized surfaces were assessed for their in vitro cell-material interactions using human fetal osteoblast (hFOB) cells for 3, 7 and 11 days, and Ni ion release up to 8 weeks in simulated body fluids. The results were correlated with the surface morphologies of anodized surfaces characterized using field-emission scanning electron microscopy (FESEM). The results show that anodization creates a surface with nano/micro-roughness depending on the anodization conditions. The hydrophilicity of the NiTi surface was found to improve after anodization, as shown by the lower contact angles in cell medium, which dropped from 32° to <5°. The improved wettability of anodized surfaces is further corroborated by their high surface energy, comparable with that of commercially pure Ti. Relatively high surface energies, especially the polar component, and nano/micro surface features of anodized surfaces significantly increased the number of living cells and their adherence and growth on these surfaces. Finally, a significant drop in Ni ion release from 268±11 to 136±15 ppb was observed for NiTi surfaces after anodization. This work indicates that anodization of a NiTi alloy has a positive influence on the surface energy and surface morphology, which in turn improves bone cell-material interactions and reduces Ni ion release in vitro. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. The first principle study of Ni{sub 2}ScGa and Ni{sub 2}TiGa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Özduran, Mustafa; Turgut, Kemal; Arikan, Nihat

    2014-10-06

    We computed the electronic structure, elastic moduli, vibrational properties, and Ni{sub 2}TiGa and Ni{sub 2}ScGa alloys in the cubic L2{sub 1} structure. The obtained equilibrium lattice constants of these alloys are in good agreement with available data. In cubic systems, there are three independent elastic constants, namely C{sub 11}, C{sub 12} and C{sub 44}. We calculated elastic constants in L2{sub 1} structure for Ni{sub 2}TiGa and Ni{sub 2}ScGa using the energy-strain method. The electronic band structure, total and partial density of states for these alloys were investigated within density functional theory using the plane-wave pseudopotential method implemented in Quantum-Espresso programmore » package. From band structure, total and projected density of states, we observed metallic characters of these compounds. The electronic calculation indicate that the predominant contributions of the density of states at Fermi level come from the Ni 3d states and Sc 3d states for Ni{sub 2}TiGa, Ni 3d states and Sc 3d states for Ni{sub 2}ScGa. The computed density of states at Fermi energy are 2.22 states/eV Cell for Ni{sub 2}TiGa, 0.76 states/eV Cell for Ni{sub 2}ScGa. The vibrational properties were obtained using a linear response in the framework at the density functional perturbation theory. For the alloys, the results show that the L2{sub 1} phase is unstable since the phonon calculations have imagine modes.« less

  19. Fabricating micro-instruments in surface-micromachined polycrystalline silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Comtois, J.H.; Michalicek, M.A.; Barron, C.C.

    1997-04-01

    Smaller, lighter instruments can be fabricated as Micro-Electro-Mechanical Systems (MEMS), having micron scale moving parts packaged together with associated control and measurement electronics. Batch fabrication of these devices will make economical applications such as condition-based machine maintenance and remote sensing. The choice of instrumentation is limited only by the designer`s imagination. This paper presents one genre of MEMS fabrication, surface-micromachined polycrystalline silicon (polysilicon). Two currently available but slightly different polysilicon processes are presented. One is the ARPA-sponsored ``Multi-User MEMS ProcesS`` (MUMPS), available commercially through MCNC; the other is the Sandia National Laboratories ``Sandia Ultra-planar Multilevel MEMS Technology`` (SUMMiT). Example componentsmore » created in both processes will be presented, with an emphasis on actuators, actuator force testing instruments, and incorporating actuators into larger instruments.« less

  20. Magnetic and conventional shape memory behavior of Mn-Ni-Sn and Mn-Ni-Sn(Fe) alloys

    NASA Astrophysics Data System (ADS)

    Turabi, A. S.; Lázpita, P.; Sasmaz, M.; Karaca, H. E.; Chernenko, V. A.

    2016-05-01

    Magnetic and conventional shape memory properties of Mn49Ni42Sn9(at.%) and Mn49Ni39Sn9Fe3(at.%) polycrystalline alloys exhibiting martensitic transformation from ferromagnetic austenite into weakly magnetic martensite are characterized under compressive stress and magnetic field. Magnetization difference between transforming phases drastically increases, while transformation temperature decreases with the addition of Fe. Both Mn49Ni42Sn9 and Mn49Ni39Sn9Fe3 alloys show remarkable superelastic and shape memory properties with recoverable strain of 4% and 3.5% under compression at room temperature, respectively. These characteristics can be counted as extraordinary among the polycrystalline NiMn-based magnetic shape memory alloys. Critical stress for phase transformation was increased by 34 MPa in Mn49Ni39Sn9Fe3 and 21 MPa in Mn49Ni42Sn9 at 9 T, which can be qualitatively understood in terms of thermodynamic Clausius-Clapeyron relationships and in the framework of the suggested physical concept of a volume magnetostress.

  1. Overview of intercalibration of satellite instruments

    USGS Publications Warehouse

    Chander, G.; Hewison, T.J.; Fox, N.; Wu, X.; Xiong, X.; Blackwell, W.J.

    2013-01-01

    Inter-calibration of satellite instruments is critical for detection and quantification of changes in the Earth’s environment, weather forecasting, understanding climate processes, and monitoring climate and land cover change. These applications use data from many satellites; for the data to be inter-operable, the instruments must be cross-calibrated. To meet the stringent needs of such applications requires that instruments provide reliable, accurate, and consistent measurements over time. Robust techniques are required to ensure that observations from different instruments can be normalized to a common scale that the community agrees on. The long-term reliability of this process needs to be sustained in accordance with established reference standards and best practices. Furthermore, establishing physical meaning to the information through robust Système International d'unités (SI) traceable Calibration and Validation (Cal/Val) is essential to fully understand the parameters under observation. The processes of calibration, correction, stability monitoring, and quality assurance need to be underpinned and evidenced by comparison with “peer instruments” and, ideally, highly calibrated in-orbit reference instruments. Inter-calibration between instruments is a central pillar of the Cal/Val strategies of many national and international satellite remote sensing organizations. Inter-calibration techniques as outlined in this paper not only provide a practical means of identifying and correcting relative biases in radiometric calibration between instruments but also enable potential data gaps between measurement records in a critical time series to be bridged. Use of a robust set of internationally agreed upon and coordinated inter-calibration techniques will lead to significant improvement in the consistency between satellite instruments and facilitate accurate monitoring of the Earth’s climate at uncertainty levels needed to detect and attribute the mechanisms

  2. Process development for Ni-Cr-ThO2 and Ni-Cr-Al-ThO2 sheet

    NASA Technical Reports Server (NTRS)

    Cook, R. C.; Norris, L. F.

    1973-01-01

    A process was developed for the production of thin gauge Ni-Cr-ThO2 sheet. The process was based on the elevated temperature deposition of chromium onto a wrought Ni-2%ThO2 sheet and subsequent high temperature diffusion heat treatments to minimize chromium concentration gradients within the sheet. The mechanical properties of the alloy were found to be critically dependent on those of the Ni-2%ThO2 sheet. A similar process for the production of a Ni-Cr-Al-ThO2 alloy having improved oxidation resistance was investigated but the non-reproducible deposition of aluminum from duplex Cr/Al packs precluded successful scale-up. The mechanical properties of the Ni-Cr-Al-ThO2 alloys were generally equivalent to the best Ni-Cr-ThO2 alloy produced in the programme.

  3. Development of Mirror Modules for the ART-XC Instrument aboard the Spectrum-Roentgen-Gamma Mission

    NASA Technical Reports Server (NTRS)

    Gubarev, M; Ramsey, B.; O'Dell, S. L.; Elsner, R.; Kilaru, K.; McCracken, J.; Pavlinsky, M.; Tkachenko, A.; Lapshov, I.; Atkins, C.; hide

    2013-01-01

    The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART-XC instrument on board the Spectrum-Roentgen Gamma Mission. Four of those modules are being fabricated under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) An additional three flight modules and one spare for the ART-XC Instrument are produced under a Cooperative Agreement between NASA and IKI. The instrument will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Each module consists of 28 nested thin Ni/Co shells giving an effective area of 65 cm2 at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. Delivery of the first four modules is scheduled for November 2013, while the remaining three modules will be delivered to IKI in January 2014. We present a status of the ART x-ray module development at MSFC.

  4. Development of mirror modules for the ART-XC instrument aboard the Spectrum-Roentgen-Gamma mission

    NASA Astrophysics Data System (ADS)

    Gubarev, M.; Ramsey, B.; O'Dell, S. L.; Elsner, R.; Kilaru, K.; McCracken, J.; Pavlinsky, M.; Tkachenko, A.; Lapshov, I.; Atkins, C.; Zavlin, V.

    2013-09-01

    The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART-XC instrument on board the Spectrum-Roentgen Gamma Mission. Four of those modules are being fabricated under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) An additional three flight modules and one spare for the ART-XC Instrument are produced under a Cooperative Agreement between NASA and IKI. The instrument will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Each module consists of 28 nested thin Ni/Co shells giving an effective area of 65 cm2 at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. Delivery of the first four modules is scheduled for November 2013, while the remaining three modules will be delivered to IKI in January 2014. We present a status of the ART x-ray module development at MSFC.

  5. Comparative Evaluation of Physical Surface Changes and Incidence of Separation in Rotary Nickel-Titanium Instruments: An in Vitro SEM Study

    PubMed Central

    Kaul, Rudra; Farooq, Riyaz; Kaul, Vibhuti; Khateeb, Shafayat Ullah; Purra, Aamir Rashid; Mahajan, Roopali

    2014-01-01

    Introduction: The aim of the present study was to comparatively evaluate the physical surface changes and incidence of separation in rotary nickel-titanium (NiTi) instruments using scanning electron microscope (SEM). Methods and Materials: A total number of 210 freshly extracted human maxillary and mandibular first molars were selected and distributed between three groups. Three different systems of rotary NiTi instruments, namely ProFile (PF), RaCe (RC) and Twisted File (TF), were used to prepare the canals using crown-down technique. All instruments were evaluated by means of SEM with 500× and 1500× magnifications, at four different stages; before use, after preparation of 7 and 14 canals and after instrument separation. Photomicrographs were also taken. The data was analyzed using the Kruskal-Wallis test and the level of significance was set at 0.001. It was found that H (HAT matrix) was 15.316 with 2 degrees of freedom. Moreover the various groups were compared using the Student-Newman-Keuls test with P<0.05 and it was found that all groups were significantly different. Results: RC showed the maximum wear of the surface followed by TF (P<0.05). PF showed the minimum wear except for its tip. There was no correlation between electropolishing and file fracture. Insignificant difference was observed in the mean number of canals shaped by PF and TF before their separation. Conclusion: Clinically, TF performance was superior, followed by PF then RC. RC fracture rate was the greatest after preparing the least number of canals. PMID:25031595

  6. The asymmetric response of Yangtze river basin summer rainfall to El Niño/La Niña

    NASA Astrophysics Data System (ADS)

    Hardiman, Steven C.; Dunstone, Nick J.; Scaife, Adam A.; Bett, Philip E.; Li, Chaofan; Lu, Bo; Ren, Hong-Li; Smith, Doug M.; Stephan, Claudia C.

    2018-02-01

    The Yangtze river basin, in South East China, experiences anomalously high precipitation in summers following El Niño. This can lead to extensive flooding and loss of life. However, the response following La Niña has not been well documented. In this study, the response of Yangtze summer rainfall to El Niño/La Niña is found to be asymmetric, with no significant response following La Niña. The nature of this asymmetric response is found to be in good agreement with that simulated by the Met Office seasonal forecast system. Yangtze summer rainfall correlates positively with spring sea surface temperatures in the Indian Ocean and northwest Pacific. Indian Ocean sea surface temperatures are found to respond linearly to El Niño/La Niña, and to have a linear impact on Yangtze summer rainfall. However, northwest Pacific sea surface temperatures respond much more strongly following El Niño and, further, correlate more strongly with positive rainfall years. It is concluded that, whilst delayed Indian Ocean signals may influence summer Yangtze rainfall, it is likely that they do not lead to the asymmetric nature of the rainfall response to El Niño/La Niña.

  7. Ni3Si2 nanowires grown in situ on Ni foam for high-performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Jiang, Yizhe; Li, Zhihui; Li, Beibei; Zhang, Jinying; Niu, Chunming

    2016-07-01

    Ni3Si2 nanowires and nanoawls have grown in situ on the surface of Ni foams by a controlled low pressure chemical vapor deposition process. Structural characterization shows that the individual Ni3Si2 nanowire is single crystal covered with a thin layer (1-2 nm) of SiO2 with a diameter of ∼20-30 nm and length of ten's micrometers. Individual nanoawl with a circular cone shape is polycrystalline. Both Ni3Si2 nanowire and nanoawl samples are evaluated as potential electrode materials for supercapacitors. The nanowire electrode delivers a very high specific capacitance and excellent rate capability. A specific capacitance of 760 F g-1 is measured at current density of 0.5 A g-1, which decreases to 518 F g-1 when the current density increases to 10 A g-1. The capacitance is dominated by pseudocapacitance with a mechanism similar to that of NiO or Ni(OH)2 widely studied in the literature. An asymmetric supercapacitor fabricated by pairing Ni3Si2 nanowire electrode with an activated carbon electrode exhibits energy densities of 17.5 Wh kg-1 and 8.8 Wh kg-1 at power densites of 301 W kg-1 and 3000 W kg-1.

  8. Fluorescence x-ray absorption fine structure studies of Fe-Ni-S and Fe-Ni-Si melts to 1600 K

    NASA Astrophysics Data System (ADS)

    Manghnani, M. H.; Hong, X.; Balogh, J.; Amulele, G.; Sekar, M.; Newville, M.

    2008-04-01

    We report NiK -edge fluorescence x-ray absorption fine structure spectra (XAFS) for Fe0.75Ni0.05S0.20 and Fe0.75Ni0.05Si0.20 ternary alloys from room temperature up to 1600 K. A high-temperature furnace designed for these studies incorporates two x-ray transparent windows and enables both a vertical orientation of the molten sample and a wide opening angle, so that XAFS can be measured in the fluorescence mode with a detector at 90° with respect to the incident x-ray beam. An analysis of the Ni XAFS data for these two alloys indicates different local structural environments for Ni in Fe0.75Ni0.05S0.20 and Fe0.75Ni0.05Si0.20 melts, with more Ni-Si coordination than Ni-S coordination persisting from room temperature through melting. These results suggest that light elements such as S and Si may impact the structural and chemical properties of Fe-Ni alloys with a composition similar to the earth’s core.

  9. Thermal modeling of NiH2 batteries

    NASA Technical Reports Server (NTRS)

    Ponthus, Agnes-Marie; Alexandre, Alain

    1994-01-01

    The following are discussed: NiH2 battery mission and environment; NiH2 cell heat dissipation; Nodal software; model development general philosophy; NiH2 battery model development; and NiH2 experimental developments.

  10. The Hydrologic Instrumentation Facility of the U.S. Geological Survey

    USGS Publications Warehouse

    Wagner, C.R.; Jeffers, Sharon

    1984-01-01

    The U.S. Geological Survey Water Resources Division has improved support to the agencies field offices by the consolidation of all instrumentation support services in a single facility. This facility known as the Hydrologic Instrumentation Facility (HIF) is located at the National Space Technology Laboratory, Mississippi, about 50 miles east of New Orleans, Louisiana. The HIF is responsible for design and development, testing, evaluation, procurement, warehousing, distribution and repair of a variety of specialized hydrologic instrumentation. The centralization has resulted in more efficient and effective support of the Survey 's hydrologic programs. (USGS)

  11. Who is El Niño?

    NASA Astrophysics Data System (ADS)

    Philander, S. George

    It is a curious story, about a phenomenon we first welcomed as a blessing but now view with dismay, if not horror [Philander, 1998]. We named it El Niño for the child Jesus, provided it with relatives—La Niña and ENSO—and are devoting innumerable studies to the description and idealization of this family. These scriptures provide such a broad spectrum of historical, cultural, and scientific perspectives that there is now confusion about the identity of El Niño. Trenberth [1997] summarizes the situation as follows.The atmospheric component tied to El Niño is termed the “Southern Oscillation.” Scientists often call the phenomenon where the atmosphere and ocean collaborate ENSO, short for El Niño-Southern Oscillation. El Niño then corresponds to the warm phase of ENSO. The opposite “La Niña” (“the girl” in Spanish) phase consists of a basinwide cooling of the tropical Pacific and thus the cold phase of ENSO. However, for the public, the term for the whole phenomenon is “El Niño.”

  12. Thermo Scientific Sulfur Dioxide Analyzer Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Springston, S. R.

    The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO2 + hυ1 →SO2 *→SO2 + hυ2 The emitted light is proportional to the concentration of SO2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers throughmore » the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. BNL has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.« less

  13. Synthesis and catalytic activity of electrospun NiO/NiCo2O4 nanotubes for CO and acetaldehyde oxidation

    NASA Astrophysics Data System (ADS)

    Kim, Il Hee; Lee, Hyerim; Yu, Areum; Jeong, Jae Hwan; Lee, Youngmi; Kim, Myung Hwa; Lee, Chongmok; Dok Kim, Young

    2018-04-01

    NiO/NiCo2O4 nanotubes with a diameter of approximately 100 nm are synthesized using Ni and Co precursors via electro-spinning and subsequent calcination processes. The tubular structure is confirmed via transmission electron microscopy imaging, whereas the structures and elemental compositions of the nanotubes are determined using x-ray diffraction, energy dispersive x-ray spectroscopy, and x-ray photoelectron spectroscopy. N2 adsorption isotherm data reveal that the surface of the nanotubes consists of micropores, thereby resulting in a significantly higher surface area (˜20 m2 g-1) than expected for a flat-surface structure (<15 m2 g-1). Herein, we present a study of the catalytic activity of our novel NiO/NiCo2O4 nanotubes for CO and acetaldehyde oxidation. The catalytic activity of NiO/NiCo2O4 is superior to Pt below 100 °C for CO oxidation. For acetaldehyde oxidation, the total oxidation activity of NiO/NiCo2O4 for acetaldehyde is comparable with that of Pt. Coexistence of many under-coordinated Co and Ni active sites in our structure is suggested be related to the high catalytic activity. It is suggested that our novel NiO/NiCo2O4 tubular structures with surface microporosity can be of interest for a variety of applications, including the catalytic oxidation of harmful gases.

  14. Synthesis and catalytic activity of electrospun NiO/NiCo2O4 nanotubes for CO and acetaldehyde oxidation.

    PubMed

    Kim, Il Hee; Lee, Hyerim; Yu, Areum; Jeong, Jae Hwan; Lee, Youngmi; Kim, Myung Hwa; Lee, Chongmok; Kim, Young Dok

    2018-04-27

    NiO/NiCo 2 O 4 nanotubes with a diameter of approximately 100 nm are synthesized using Ni and Co precursors via electro-spinning and subsequent calcination processes. The tubular structure is confirmed via transmission electron microscopy imaging, whereas the structures and elemental compositions of the nanotubes are determined using x-ray diffraction, energy dispersive x-ray spectroscopy, and x-ray photoelectron spectroscopy. N 2 adsorption isotherm data reveal that the surface of the nanotubes consists of micropores, thereby resulting in a significantly higher surface area (∼20 m 2 g -1 ) than expected for a flat-surface structure (<15 m 2 g -1 ). Herein, we present a study of the catalytic activity of our novel NiO/NiCo 2 O 4 nanotubes for CO and acetaldehyde oxidation. The catalytic activity of NiO/NiCo 2 O 4 is superior to Pt below 100 °C for CO oxidation. For acetaldehyde oxidation, the total oxidation activity of NiO/NiCo 2 O 4 for acetaldehyde is comparable with that of Pt. Coexistence of many under-coordinated Co and Ni active sites in our structure is suggested be related to the high catalytic activity. It is suggested that our novel NiO/NiCo 2 O 4 tubular structures with surface microporosity can be of interest for a variety of applications, including the catalytic oxidation of harmful gases.

  15. 32 CFR 644.411 - Form of inter-agency transfer instrument.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Form of inter-agency transfer instrument. 644.411 Section 644.411 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL... of the Secretary of the transferring department and will be addressed to the Secretary of head of the...

  16. El Niño revisited: the influence of El Niño Southern Oscillation on the world's largest tuna fisheries.

    NASA Astrophysics Data System (ADS)

    Receveur, A.; Simon, N.; Menkes, C.; Tremblay-Boyer, L.; Senina, I.; Lehodey, P.

    2016-12-01

    El Niño Southern Oscillation (ENSO) drives global climate on inter-annual scales and impacts the ecosystem structure in the warm-pool and cold-tongue of the Pacific Ocean. During the El Niño phase of ENSO, the warm-pool can stretch from the western equatorial Pacific to the eastern Pacific allowing species associated with the warm-pool to correspondingly spread eastwards. Conversely, during the la Niña phase the warm-pool is pushed to the far western equatorial Pacific by the cold-tongue allowing species associated with this ecosystem to spread westwards. Consequently, ENSO dynamics are likely to be critical for understanding the ecological processes supporting fisheries in the equatorial Pacific Ocean. Surface inhabiting tuna, such as skipjack, are thought to track the convergence of the warm-pool and cold-tongue with fishing vessels tracking this tuna behavior. Given the reliance of Pacific Island economies on tuna fisheries, knowing when tunas are more likely to be present in high density in their territorial waters is beneficial for harvest control policies such as effort trading between nations. We use the SEAPODYM model to investigate the response of bigeye and skipjack tuna species to the phases of ENSO. SEAPODYM is an age structured model that integrates fisheries dependent and independent data with environmental data. We analyze the outputs of SEAPODYM using wavelets to assess the impact of environmental and biotic variables on the abundance and distribution of adult and juvenile age classes and to study time series cycle and temporal lags to ENSO. The main result for skipjack is the eastward or westward movement of the biomass pattern which is significantly lagged with the warm pool ENSO displacement. That lag ranges from 8 months for juvenile up to 18 months for adults. Such delayed response, can be traced in the model. Higher temperature in the central Pacific during El Niño leads to better recruitment which leads to lagged increase of juvenile

  17. Inter-calibration and validation of observations from SAPHIR and ATMS instruments

    NASA Astrophysics Data System (ADS)

    Moradi, I.; Ferraro, R. R.

    2015-12-01

    We present the results of evaluating observations from microwave instruments aboard the Suomi National Polar-orbiting Partnership (NPP, ATMS instrument) and Megha-Tropiques (SAPHIR instrument) satellites. The study includes inter-comparison and inter-calibration of observations of similar channels from the two instruments, evaluation of the satellite data using high-quality radiosonde data from Atmospheric Radiation Measurement Program and GPS Radio Occultaion Observations from COSMIC mission, as well as geolocation error correction. The results of this study are valuable for generating climate data records from these instruments as well as for extending current climate data records from similar instruments such as AMSU-B and MHS to the ATMS and SAPHIR instruments. Reference: Moradi et al., Intercalibration and Validation of Observations From ATMS and SAPHIR Microwave Sounders. IEEE Transactions on Geoscience and Remote Sensing. 01/2015; DOI: 10.1109/TGRS.2015.2427165

  18. The influence of Si in Ni on the interface modification and the band alignment between Ni and alumina

    NASA Astrophysics Data System (ADS)

    Yoshitake, Michiko; Nemšák, Slavomír; Skála, Tomáš; Tsud, Nataliya; Matolín, Vladimír; Prince, Kevin C.

    2018-06-01

    The influence of a small amount of Si in a Ni single crystal on the interface formation between aluminum oxide and Ni has been investigated. The interface was formed by in-situ growth of the oxide by simultaneous supply of Al and oxygen onto Ni(1 1 1) in an ultrahigh vacuum chamber equipped with XPS apparatus. The oxide growth and the interface formation were compared between Si-containing Ni(1 1 1) and pure Ni(1 1 1). It was revealed that Si segregated on the surface of Ni and oxidized, forming an epitaxial thin alumino-silicate film. Valence band spectra demonstrated that the band offset between the oxide and Ni (energy level difference between the valence band top and the Fermi level) is different due to the oxidized Si segregation at the interface.

  19. Metal-semiconductor interfacial reactions - Ni/Si system

    NASA Technical Reports Server (NTRS)

    Cheung, N. W.; Grunthaner, P. J.; Grunthaner, F. J.; Mayer, J. W.; Ullrich, B. M.

    1981-01-01

    X-ray photoelectron spectroscopy and channeling measurements with MeV He-4(+) ions have been used to probe the structure of the interface in the Ni/Si system. It is found that reactions occur where Ni is deposited on Si at 10 to the -10th torr: Si atoms are displaced from lattice sites, the Ni atoms are in an Si-rich environment, and the Ni/Si interface is graded in composition. Composition gradients are present at both interfaces in the Si/Ni2/Si/Ni system. For the Ni-Si system, cooling the substrate to 100 K slows down the reaction rate. The temperature dependence of the interfacial reactivity indicates the kinetic nature of metal-semiconductor interfaces.

  20. Impact of La Niña and La Niña Modoki on Indonesia rainfall variability

    NASA Astrophysics Data System (ADS)

    Hidayat, R.; Juniarti, MD; Ma’rufah, U.

    2018-05-01

    La Niña events are indicated by cooling SST in central and eastern equatorial Pacific. While La Niña Modoki occurrences are indicated by cooling SST in central Pacific and warming SST in western and eastern equatorial Pacific. These two events are influencing rainfall variability in several regions including Indonesia. The objective of this study is to analyse the impact of La Niña and La Niña Modoki on Indonesian rainfall variability. We found the Nino 3.4 index is highly correlated (r = -0.95) with Indonesian rainfall. Positive rainfall anomalies up to 200 mm/month occurred mostly in Indonesian region during La Niña events, but in DJF several areas of Sumatera, Kalimantan and eastern Indonesia tend to have negative rainfall. During La Niña Modoki events, positive rainfall anomaly (up to 50 mm/month) occurred in Sumatera Island, Kalimantan, Java and eastern Indonesia in DJF and up to 175 mm/month occurred only in Java Island in MAM season. La Niña events have strong cooling SST in central and eastern equatorial Pacific (-1.5°C) in DJF. While La Niña Modoki events warming SST occurred in western and eastern equatorial Pacific (0.75°C) and cooling SST in central Pacific (- 0.75°C) in DJF and MAM. Walker circulation in La Niña Modoki events (on DJF and MAM) showed strong convergence in eastern Pacific, and weak convergence in western Pacific (Indonesia).

  1. [Ni III(OMe)]-mediated reductive activation of CO 2 affording a Ni(κ 1-OCO) complex

    DOE PAGES

    Chiou, Tzung -Wen; Tseng, Yen -Ming; Lu, Tsai -Te; ...

    2016-02-24

    Here, carbon dioxide is expected to be employed as an inexpensive and potential feedstock of C 1 sources for the mass production of valuable chemicals and fuel. Versatile chemical transformations of CO 2, i.e. insertion of CO 2 producing bicarbonate/acetate/formate, cleavage of CO 2 yielding μ-CO/μ-oxo transition-metal complexes, and electrocatalytic reduction of CO 2 affording CO/HCOOH/CH 3OH/CH 4/C 2H 4/oxalate were well documented. Herein, we report a novel pathway for the reductive activation of CO 2 by the [Ni III(OMe)(P(C 6H 3-3-SiMe 3-2-S) 3)] – complex, yielding the [Ni III(κ 1-OCO˙ –)(P(C 6H 3-3-SiMe 3-2-S) 3)] – complex. The formationmore » of this unusual Ni III(κ 1-OCO ˙–) complex was characterized by single-crystal X-ray diffraction, EPR, IR, SQUID, Ni/S K-edge X-ray absorption spectroscopy, and Ni valence-to-core X-ray emission spectroscopy. The inertness of the analogous complexes [Ni III(SPh)], [Ni II(CO)], and [Ni II(N 2H 4)] toward CO 2, in contrast, demonstrates that the ionic [Ni III(OMe)] core attracts the binding of weak σ-donor CO 2 and triggers the subsequent reduction of CO 2 by the nucleophilic [OMe] – in the immediate vicinity. This metal–ligand cooperative activation of CO 2 may open a novel pathway promoting the subsequent incorporation of CO 2 in the buildup of functionalized products.« less

  2. Streptococcus mutans adhesion on nickel titanium (NiTi) and copper-NiTi archwires: A comparative prospective clinical study.

    PubMed

    Abraham, Kirubaharan S; Jagdish, Nithya; Kailasam, Vignesh; Padmanabhan, Sridevi

    2017-05-01

    To compare the adhesion of Streptococcus mutans to nickel titanium (NiTi) and copper-NiTi (Cu-NiTi) archwires and to correlate the adhesion to surface characteristics (surface free energy and surface roughness) of these wires. A total of 16 patients undergoing orthodontic treatment with preadjusted edgewise appliances were included in the study. 0.016" and 0.016" × 0.022" NiTi and Cu-NiTi archwires in as-received condition and after 4 weeks of intraoral use were studied for S mutans adhesion using real-time polymerase chain reaction. Surface roughness and surface free energy were studied by three-dimensional surface profilometry and dynamic contact angle analysis, respectively. S mutans adhesion was more in Cu-NiTi archwires. These wires exhibited rougher surface and higher surface free energy when compared to NiTi archwires. S mutans adhesion, surface roughness, and surface free energy were greater in Cu-NiTi than NiTi archwires. Surface roughness and surface free energy increased after 4 weeks of intraoral exposure for all of the archwires studied. A predominantly negative correlation was seen between the cycle threshold value of adherent bacteria and surface characteristics.

  3. Flexible Rover Architecture for Science Instrument Integration and Testing

    NASA Technical Reports Server (NTRS)

    Bualat, Maria G.; Kobayashi, Linda; Lee, Susan Y.; Park, Eric

    2006-01-01

    At NASA Ames Research Center, the Intelligent Robotics Group (IRG) fields the K9 and K10 class rovers. Both use a mobile robot hardware architecture designed for extensibility and reconfigurability that allows for rapid changes in instrumentation and provides a high degree of modularity. Over the past ssveral years, we have worked with instrument developers at NASA centers, universities, and national laboratories to integrate or partially integrate their instruments onboard the K9 and K10 rovers. Early efforts required considerable interaction to work through integration issues such as power, data protocol and mechanical mounting. These interactions informed the design of our current avionics architecture, and have simplified more recent integration projects. In this paper, we will describe the IRG extensible avionics and software architecture and the effect it has had on our recent instrument integration efforts, including integration of four Mars Instrument Development Program devices.

  4. Corrosive and cytotoxic properties of compact specimens and microparticles of Ni-Cr dental alloy.

    PubMed

    Ristic, Ljubisa; Vucevic, Dragana; Radovic, Ljubica; Djordjevic, Snezana; Nikacevic, Milutin; Colic, Miodrag

    2014-04-01

    Nickel-chromium (Ni-Cr) dental alloys have been widely used in prosthodontic practice, but there is a permanent concern about their biocompatibility due to the release of metal ions. This is especially important when Ni-Cr metal microparticles are incorporated into gingival tissue during prosthodontic procedures. Therefore, the aim of this study was to examine and compare the corrosion and cytotoxic properties of compact specimens and microparticles of Ni-Cr dental alloy. Ni-Cr alloy, Remanium CSe bars (4 mm diameter), were made by the standard casting method and then cut into 0.5-mm-thick disks. Metal particles were obtained by scraping the bars using a diamond instrument for crown preparation. The microstructure was observed by an optical microscope. Quantitative determination and morphological and dimensional characterization of metal particles were carried out by a scanning electron microscope and Leica Application Suite software for image analysis. Corrosion was studied by conditioning the alloy specimens in the RPMI 1640 medium, containing 10% fetal calf serum in an incubator with 5% CO2 for 72 hours at 37°C. Inductively coupled plasma-optical emission spectrometry was used to assess metal ion release. The cytotoxity of conditioning medium (CM) was investigated on L929 cells using an MTT test. One-way ANOVA was used for statistical analysis. After casting, the microstructure of the Remanium CSe compact specimen composed of Ni, Cr, Mo, Si, Fe, Al, and Co had a typical dendritic structure. Alloy microparticles had an irregular shape with a wide size range: from less than 1 μm to more than 100 μm. The release of metal ions, especially Ni and Mo from microparticles, was significantly higher, compared to the compact alloy specimen. The CM prepared from compact alloy was not cytotoxic at any tested dilutions, whereas CM from alloy microparticles showed dose-dependent cytotoxicity (90% CM and 45% CM versus control; p < 0.005). Ni-Cr microparticles showed less

  5. Using Chelator-Buffered Nutrient Solutions to Induce Ni-Deficiency in the Ni-Hyperaccumulator Alyssum murale

    USDA-ARS?s Scientific Manuscript database

    Ni is essential for all plants due to its role in urease. Many Alyssum species are known to hyperaccumulate Ni to over 20 g kg-1 dry weight (DW) while normal plants require only about 0.1 mg kg-1 DW. As part of our research on Ni hyperaccumulation by plants, we conducted experiments to measure the...

  6. SPERTI Instrument Cell Building (PER606) elevation; plan of Guard House ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SPERT-I Instrument Cell Building (PER-606) elevation; plan of Guard House (PER-607); elevations for Pit Building (PER-605) southwest, southeast, and northeast sides. Earthen shield is mounded between back wall of Instrument Cell Building and the southwest elevation of Pit Building. Detail of filtered louver in door of Instrument Cell Building. Idaho Operations Office PER-605-IDO-3. INEEL index no. 761-0605-00-396-109183 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  7. Synthetic Ni3S2/Ni hybrid architectures as potential contrast agents in MRI

    NASA Astrophysics Data System (ADS)

    Ma, J.; Chen, K.

    2016-04-01

    Traditional magnetic resonance imaging (MRI) contrast agents mainly include superparamagnetic (SPM) iron oxide nanoparticle as T 2 contrast agent for liver and paramagnetic Gd (III)-chelate as T 1 contrast agent for all organs. In this work, weak ferromagnetic kale-like and SPM cabbage-like Ni3S2@Ni hybrid architectures were synthesized and evaluated as potential T 1 MRI contrast agents. Their relatively small r 2/r 1 ratios of 2.59 and 2.38, and high r 1 values of 11.27 and 4.89 mmol-1 L s-1 (for the kale-like and cabbage-like Ni3S2@Ni, respectively) will shed some light on the development of new-type MRI contrast agents.

  8. Hierarchical NiCo2 O4 nanosheets grown on Ni nanofoam as high-performance electrodes for supercapacitors.

    PubMed

    Gao, Guoxin; Wu, Hao Bin; Ding, Shujiang; Liu, Li-Min; Lou, Xiong Wen David

    2015-02-18

    A high-performance electrode for supercapacitors is designed and synthesized by growing electroactive NiCo2 O4 nanosheets on conductive Ni nanofoam. Because of the structural advantages, the as-prepared Ni@NiCo2 O4 hybrid nanostructure exhibits significantly improved electrochemical performance with high capacitance, excellent rate capability, and good cycling stability. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. The Ce-Ni-Si system as a representative of the rare earth-Ni-Si family: Isothermal section and new rare-earth nickel silicides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morozkin, A.V., E-mail: morozkin@tech.chem.msu.ru; Knotko, A.V.; Garshev, A.V.

    The Ce-Ni-Si system has been investigated at 870/1070 K by X-ray and microprobe analyses. The existence of the known compounds, i.e.: Ce{sub 2}Ni{sub 15.8}Si{sub 1.2} (Th{sub 2}Ni{sub 17}-type), Ce{sub 2}Ni{sub 15-14}Si{sub 2-3} (Th{sub 2}Zn{sub 17}-type), CeNi{sub 8.6}Si{sub 2.4} (BaCd{sub 11}-type), CeNi{sub 8.8}Si{sub 4.2} (LaCo{sub 9}Si{sub 4}-type), CeNi{sub 6}Si{sub 6} (CeNi{sub 6}Si{sub 6}-type), CeNi{sub 5}Si{sub 1-0.3} (TbCu{sub 7}-type), CeNi{sub 4}Si (YNi{sub 4}Si-type), CeNi{sub 2}Si{sub 2} (CeGa{sub 2}Al{sub 2}-type), Ce{sub 2}Ni{sub 3}Si{sub 5} (U{sub 2}Co{sub 3}Si{sub 5}-type), Ce{sub 3}Ni{sub 6}Si{sub 2} (Ce{sub 3}Ni{sub 6}Si{sub 2}-type), Ce{sub 3}Ni{sub 4}Si{sub 4} (U{sub 3}Ni{sub 4}Si{sub 4}-type), CeNiSi{sub 2} (CeNiSi{sub 2}-type), ~CeNi{sub 1.3}Si{sub 0.7} (unknown typemore » structure), Ce{sub 6}Ni{sub 7}Si{sub 4} (Pr{sub 6}Ni{sub 7}Si{sub 4}-type), CeNiSi (LaPtSi-type), CeNi{sub 0.8-0.3}Si{sub 1.2-1.7} (AlB{sub 2}-type), ~Ce{sub 2}Ni{sub 2}Si (unknown type structure), ~Ce{sub 4.5}Ni{sub 3.5}Si{sub 2} (unknown type structure), Ce{sub 15}Ni{sub 7}Si{sub 10} (Pr{sub 15}Ni{sub 7}Si{sub 10}-type), Ce{sub 5}Ni{sub 1.85}Si{sub 3} (Ce{sub 5}Ni{sub 1.85}Si{sub 3}-type), Ce{sub 6}Ni{sub 1.4}Si{sub 3.4} (Ce{sub 6}Ni{sub 1.67}Si{sub 3}-type), Ce{sub 7}Ni{sub 2}Si{sub 5} (Ce{sub 7}Ni{sub 2}Si{sub 5}-type) and Ce{sub 3}NiSi{sub 3} (Y{sub 3}NiSi{sub 3}-type) has been confirmed in this section. Moreover, the type structure has been determined for ~Ce{sub 2}Ni{sub 2}Si (Mo{sub 2}NiB{sub 2}-type Ce{sub 2}Ni{sub 2.5}Si{sub 0.5}) and ~Ce{sub 4.5}Ni{sub 3.5}Si{sub 2} (W{sub 3}CoB{sub 3}-type Ce{sub 3}Ni{sub 3-2.7}Si{sub 1-1.3}) and new ternary phases Ce{sub 2}Ni{sub 6.25}Si{sub 0.75} (Gd{sub 2}Co{sub 7}-type), CeNi{sub 7-7.6}Si{sub 6-5.4} (GdNi{sub 7}Si{sub 6}-type) and ~Ce{sub 27}Ni{sub 42}Si{sub 31} (unknown type structure) have been identified in this system. Quasi-binary phases, solid solutions, were detected at 870/1070 K for CeNi{sub 5}, CeNi{sub 3} and

  10. Canal transportation after root canal instrumentation: a comparative study with computed tomography.

    PubMed

    Hartmann, Mateus Silveira Martins; Barletta, Fernando Branco; Camargo Fontanella, Vânia Regina; Vanni, José Roberto

    2007-08-01

    This in vitro study used computed tomography (CT) to compare the occurrence of canal transportation in the apical third of mesiobuccal canals in maxillary molars instrumented with 3 techniques. Sixty teeth were assigned to 3 groups (n = 20), and the root canals were instrumented as follows: Group 1, hand instrumentation with K-files; Group 2, K-files coupled to an oscillatory system powered by an electric engine; Group 3, ProTaper NiTi rotary system powered by an electric engine. To compare the canal transportation produced by the different techniques, preinstrumentation and postinstrumentation 3-dimensional CT images were obtained from root cross-sections of the region located 3 mm short of the apical foramen of each root canal. The CT scans were exported to Adobe Photoshop software, and the initial and final images were superimposed to detect the root canal wall differences between them. Canal transportation was measured by the distance between the prepared canal center and the anatomic canal center. The manual technique produced lesser canal transportation (0.10 mm) than the oscillatory and rotary techniques (0.37 and 0.22 mm, respectively); this difference was statistically significant (P=.021). All studied techniques produced canal transportation.

  11. Rational Design of Hierarchically Core-Shell Structured Ni3 S2 @NiMoO4 Nanowires for Electrochemical Energy Storage.

    PubMed

    Chen, Fangshuai; Ji, Shan; Liu, Quanbing; Wang, Hui; Liu, Hao; Brett, Dan J L; Wang, Guoxiu; Wang, Rongfang

    2018-05-30

    Rational design and controllable synthesis of nanostructured materials with unique microstructure and excellent electrochemical performance for energy storage are crucially desired. In this paper, a facile method is reported for general synthesis of hierarchically core-shell structured Ni 3 S 2 @NiMoO 4 nanowires (NWs) as a binder-free electrode for asymmetric supercapacitors. Due to the intimate contact between Ni 3 S 2 and NiMoO 4 , the hierarchical structured electrodes provide a promising unique structure for asymmetric supercapacitors. The as-prepared binder-free Ni 3 S 2 @NiMoO 4 electrode can significantly improve the electrical conductivity between Ni 3 S 2 and NiMoO 4 , and effectively avoid the aggregation of NiMoO 4 nanosheets, which provide more active space for storing charge. The Ni 3 S 2 @NiMoO 4 electrode presents a high areal capacity of 1327.3 µAh cm -2 and 67.8% retention of its initial capacity when current density increases from 2 to 40 mA cm -2 . In a two-electrode Ni 3 S 2 @NiMoO 4 //active carbon cell, the active materials deliver a high energy density of 121.5 Wh kg -1 at a power density of 2.285 kW kg -1 with excellent cycling stability. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Ultrathin NiGe films prepared via catalytic solid-vapor reaction of Ni with GeH(4).

    PubMed

    Peter, Antony P; Opsomer, Karl; Adelmann, Christoph; Schaekers, Marc; Meersschaut, Johan; Richard, Olivier; Vaesen, Inge; Moussa, Alain; Franquet, Alexis; Zsolt, Tokei; Van Elshocht, Sven

    2013-10-09

    A low-temperature (225-300 °C) solid-vapor reaction process is reported for the synthesis of ultrathin NiGe films (∼6-23 nm) on 300 mm Si wafers covered with thermal oxide. The films were prepared via catalytic chemical vapor reaction of germane (GeH4) gas with physical vapor deposited (PVD) Ni films of different thickness (2-10 nm). The process optimization by investigating GeH4 partial pressure, reaction temperature, and time shows that low resistive, stoichiometric, and phase pure NiGe films can be formed within a broad window. NiGe films crystallized in an orthorhombic structure and were found to exhibit a smooth morphology with homogeneous composition as evidenced by glancing angle X-ray diffraction (GIXRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), and Rutherford back-scattering (RBS) analysis. Transmission electron microscopy (TEM) analysis shows that the NiGe layers exhibit a good adhesion without voids and a sharp interface on the thermal oxide. The NiGe films were found to be morphologically and structurally stable up to 500 °C and exhibit a resistivity value of 29 μΩ cm for 10 nm NiGe films.

  13. In-Situ Synthesis of NiMoO4 on Ni Foam as a Binder-Free Electrode for Supercapacitor

    NASA Astrophysics Data System (ADS)

    Chiu, Ta-Wei

    Transition metal oxides have attracted much attention for electrode materials of supercapacitors due to their outstanding capacitive behavior. One of them is NiMoO4 with the high electrochemical activity of Ni. Constricted by its intrinsically poor electrical conductivity and limited electroactive sites of aggregated NiMoO4, the capacitive performance of NiMoO 4 are far below expectation. Directly growth of NiMoO4 on nickel foam to fabricate binder-free electrodes is proposed to solve the issues. In this thesis, we successfully constructed interconnected NiMoO4 nanosheets on the Ni foam by a designed reaction between H2MoO 4 aqueous solution and Ni foam. The effects of H2MoO 4 concentration and reaction time were systematically investigated. The best electrochemical performance of NiMoO4 electrodes can be obtained with 0.005 M H2MoO4 for 80 hours. The maximum areal capacitance can reach 0.724 F/cm2 followed with outstanding rate capability (70.1% capacitance retention when current density increase from 1 mA/cm2 to 10 mA/cm2). The excellent areal capacitance and rate capability may be attributed to its interconnected NiMoO 4 nanosheets and good adhesion between electroactive materials and current collector.

  14. An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments.

    PubMed

    Peters, O A; Gluskin, A K; Weiss, R A; Han, J T

    2012-11-01

    To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickel-titanium alloy. The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination, as well as measurement of torque (in Ncm) and apical force (in N) during canal preparation. Fatigue limit (in numbers of cycles to failure) was determined in a 90°, 5 mm radius block-and-rod assembly. Simulated canals in plastic blocks were prepared using both a manufacturer-recommended single-length technique as well as a generic crown-down approach. anova with Bonferroni post hoc procedures was used for statistical analysis. Torque at failure ranged from 0.47 to 1.38 Ncm, with significant differences between instrument sizes (P < 0.0001). Fatigue life ranged from 260 to 2565, with the shortest and longest lifespan for instruments size 20, .04 taper and size 25, .08 taper, respectively. Torque during canal preparation was significantly higher for small instruments used in the single-length technique but lower for the size 40, .04 taper, compared to a crown-down approach. No instrument fractured; 82% of the instruments used were plastically deformed; however, only 37% of these remained deformed after a sterilization cycle. Hyflex rotary instruments are bendable and flexible and have similar torsional resistance compared to instruments made of conventional NiTi. Fatigue resistance is much higher, and torque during preparation is less, compared to other rotary instruments tested previously under similar conditions. © 2012 International Endodontic Journal.

  15. Vacuum ultraviolet instrumentation for solar irradiance and thermospheric airglow

    NASA Technical Reports Server (NTRS)

    Woods, Thomas N.; Rottman, Gary J.; Bailey, Scott M.; Solomon, Stanley C.

    1993-01-01

    A NASA sounding rocket experiment was developed to study the solar extreme ultraviolet (EUV) spectral irradiance and its effect on the upper atmosphere. Both the solar flux and the terrestrial molecular nitrogen via the Lyman-Birge-Hopfield bands in the far ultraviolet (FUV) were measured remotely from a sounding rocket on October 27, 1992. The rocket experiment also includes EUV instruments from Boston University (Supriya Chakrabarti), but only the National Center for Atmospheric Research (NCAR)/University of Colorado (CU) four solar instruments and one airglow instrument are discussed here. The primary solar EUV instrument is a 1/4 meter Rowland circle EUV spectrograph which has flown on three rockets since 1988 measuring the solar spectral irradiance from 30 to 110 nm with 0.2 nm resolution. Another solar irradiance instrument is an array of six silicon XUV photodiodes, each having different metallic filters coated directly on the photodiodes. This photodiode system provides a spectral coverage from 0.1 to 80 nm with about 15 nm resolution. The other solar irradiance instrument is a silicon avalanche photodiode coupled with pulse height analyzer electronics. This avalanche photodiode package measures the XUV photon energy providing a solar spectrum from 50 to 12,400 eV (25 to 0.1 nm) with an energy resolution of about 50 eV. The fourth solar instrument is an XUV imager that images the sun at 17.5 nm with a spatial resolution of 20 arc-seconds. The airglow spectrograph measures the terrestrial FUV airglow emissions along the horizon from 125 to 160 nm with 0.2 nm spectral resolution. The photon-counting CODACON detectors are used for three of these instruments and consist of coded arrays of anodes behind microchannel plates. The one-dimensional and two-dimensional CODACON detectors were developed at CU by Dr. George Lawrence. The pre-flight and post-flight photometric calibrations were performed at our calibration laboratory and at the Synchrotron Ultraviolet

  16. Early Grade Writing Assessment: An Instrument Model

    ERIC Educational Resources Information Center

    Jiménez, Juan E.

    2017-01-01

    The United Nations Educational, Scientific, and Cultural Organization promoted the creation of a model instrument for individual assessment of students' foundational writing skills in the Spanish language that was based on a literature review and existing writing tools and assessments. The purpose of the "Early Grade Writing Assessment"…

  17. Does Extreme El Niño Have a Different Effect on the Stratosphere in Boreal Winter Than Its Moderate Counterpart?

    NASA Astrophysics Data System (ADS)

    Zhou, Xin; Li, Jianping; Xie, Fei; Chen, Quanliang; Ding, Ruiqiang; Zhang, Wenxia; Li, Yang

    2018-03-01

    A robust impact of El Niño on the Northern Hemisphere (NH) polar stratosphere has been demonstrated by previous studies, although whether this applies to extreme El Niño is uncertain. The time evolution of the response of the NH stratospheric vortex to extreme El Niño, compared with that to moderate eastern Pacific El Niño, is addressed by means of composite analysis using the National Centers for Environmental Prediction/Department of Energy reanalysis data set from 1980 to 2016. Lead-lag analysis indicates that the El Niño signal actually leads the stratospheric response by 2 months. Considering the time lag, the signal of December-January-February El Niño in the NH stratospheric vortex should mature in the February-March-April season (late winter/early spring). The patterns of circulation and temperature for late winter/early spring during extreme and moderate El Niño events are significant, exhibiting similar structure. The results are confirmed with the Whole Atmosphere Community Climate Model version 4 model, which is forced with observed SSTs of extreme and moderate El Niño in winter (December-January-February) to analyze the day-to-day propagation of their signals. Note that the magnitudes of the stratospheric responses are much larger in the case of extreme El Niño, as stronger upward propagation of planetary waves leads to a weaker northern polar vortex than during moderate El Niño events.

  18. Improved ethanol electrooxidation performance by shortening Pd-Ni active site distance in Pd-Ni-P nanocatalysts

    NASA Astrophysics Data System (ADS)

    Chen, Lin; Lu, Lilin; Zhu, Hengli; Chen, Yueguang; Huang, Yu; Li, Yadong; Wang, Leyu

    2017-01-01

    Incorporating oxophilic metals into noble metal-based catalysts represents an emerging strategy to improve the catalytic performance of electrocatalysts in fuel cells. However, effects of the distance between the noble metal and oxophilic metal active sites on the catalytic performance have rarely been investigated. Herein, we report on ultrasmall (~5 nm) Pd-Ni-P ternary nanoparticles for ethanol electrooxidation. The activity is improved up to 4.95 A per mgPd, which is 6.88 times higher than commercial Pd/C (0.72 A per mgPd), by shortening the distance between Pd and Ni active sites, achieved through shape transformation from Pd/Ni-P heterodimers into Pd-Ni-P nanoparticles and tuning the Ni/Pd atomic ratio to 1:1. Density functional theory calculations reveal that the improved activity and stability stems from the promoted production of free OH radicals (on Ni active sites) which facilitate the oxidative removal of carbonaceous poison and combination with CH3CO radicals on adjacent Pd active sites.

  19. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

    PubMed

    Özyürek, Taha; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. PTG showed significantly higher NCF than PTU and PTN in group 1 ( p < 0.05). Sterilization significantly increased the NCF of PTN and PTG ( p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 ( p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 ( p < 0.05). PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

  20. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

    PubMed Central

    2017-01-01

    Objectives It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG. PMID:29142878