Science.gov

Sample records for on-line laser ion

  1. Resonance ionization laser ion sources for on-line isotope separators (invited).

    PubMed

    Marsh, B A

    2014-02-01

    A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented. PMID:24593628

  2. Resonance ionization laser ion sources for on-line isotope separators (invited)

    NASA Astrophysics Data System (ADS)

    Marsh, B. A.

    2014-02-01

    A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented.

  3. Resonance ionization laser ion sources for on-line isotope separators (invited)

    SciTech Connect

    Marsh, B. A.

    2014-02-15

    A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented.

  4. Upgrade of the resonance ionization laser ion source at ISOLDE on-line isotope separation facility: new lasers and new ion beams.

    PubMed

    Fedosseev, V N; Berg, L-E; Fedorov, D V; Fink, D; Launila, O J; Losito, R; Marsh, B A; Rossel, R E; Rothe, S; Seliverstov, M D; Sjödin, A M; Wendt, K D A

    2012-02-01

    The resonance ionization laser ion source (RILIS) produces beams for the majority of experiments at the ISOLDE on-line isotope separator. A substantial improvement in RILIS performance has been achieved through a series of upgrade steps: replacement of the copper vapor lasers by a Nd:YAG laser; replacement of the old homemade dye lasers by new commercial dye lasers; installation of a complementary Ti:Sapphire laser system. The combined dye and Ti:Sapphire laser system with harmonics is capable of generating beams at any wavelength in the range of 210-950 nm. In total, isotopes of 31 different elements have been selectively laser-ionized and separated at ISOLDE, including recently developed beams of samarium, praseodymium, polonium, and astatine. PMID:22380244

  5. Upgrade of the resonance ionization laser ion source at ISOLDE on-line isotope separation facility: New lasers and new ion beamsa)

    NASA Astrophysics Data System (ADS)

    Fedosseev, V. N.; Berg, L.-E.; Fedorov, D. V.; Fink, D.; Launila, O. J.; Losito, R.; Marsh, B. A.; Rossel, R. E.; Rothe, S.; Seliverstov, M. D.; Sjödin, A. M.; Wendt, K. D. A.

    2012-02-01

    The resonance ionization laser ion source (RILIS) produces beams for the majority of experiments at the ISOLDE on-line isotope separator. A substantial improvement in RILIS performance has been achieved through a series of upgrade steps: replacement of the copper vapor lasers by a Nd:YAG laser; replacement of the old homemade dye lasers by new commercial dye lasers; installation of a complementary Ti:Sapphire laser system. The combined dye and Ti:Sapphire laser system with harmonics is capable of generating beams at any wavelength in the range of 210-950 nm. In total, isotopes of 31 different elements have been selectively laser-ionized and separated at ISOLDE, including recently developed beams of samarium, praseodymium, polonium, and astatine.

  6. First application of the Laser Ion Source and Trap (LIST) for on-line experiments at ISOLDE

    NASA Astrophysics Data System (ADS)

    Fink, D. A.; Richter, S. D.; Bastin, B.; Blaum, K.; Catherall, R.; Cocolios, T. E.; Fedorov, D. V.; Fedosseev, V. N.; Flanagan, K. T.; Ghys, L.; Gottberg, A.; Imai, N.; Kron, T.; Lecesne, N.; Lynch, K. M.; Marsh, B. A.; Mendonca, T. M.; Pauwels, D.; Rapisarda, E.; Ramos, J. P.; Rossel, R. E.; Rothe, S.; Seliverstov, M. D.; Sjödin, M.; Stora, T.; Van Beveren, C.; Wendt, K. D. A.

    2013-12-01

    The Laser Ion Source and Trap (LIST) provides a new mode of operation for the resonance ionization laser ion source (RILIS) at ISOLDE/CERN, reducing the amount of surface-ionized isobaric contaminants by up to four orders of magnitude. After the first successful on-line test at ISOLDE in 2011 the LIST was further improved in terms of efficiency, selectivity, and reliability through several off-line tests at Mainz University and at ISOLDE. In September 2012, the first on-line physics experiments to use the LIST took place at ISOLDE. The measurements of the improved LIST indicate more than a twofold increase in efficiency compared to the LIST of the 2011 run. The suppression of surface-ionized francium contaminants has enabled the first in-source laser spectroscopy of 217Po and 219Po.

  7. On-line experimental results of an argon gas cell-based laser ion source (KEK Isotope Separation System)

    NASA Astrophysics Data System (ADS)

    Hirayama, Y.; Watanabe, Y. X.; Imai, N.; Ishiyama, H.; Jeong, S. C.; Jung, H. S.; Miyatake, H.; Oyaizu, M.; Kimura, S.; Mukai, M.; Kim, Y. H.; Sonoda, T.; Wada, M.; Huyse, M.; Kudryavtsev, Yu.; Van Duppen, P.

    2016-06-01

    KEK Isotope Separation System (KISS) has been developed at RIKEN to produce neutron rich isotopes with N = 126 to study the β -decay properties for application to astrophysics. The KISS is an element-selective mass-separation system which consists of an argon gas cell-based on laser ion source for atomic number selection and an ISOL mass-separation system. The argon gas cell of KISS is a key component to stop and collect the unstable nuclei produced in a multi-nucleon transfer reaction, where the isotopes of interest will be selectively ionized using laser resonance ionization. We have performed off- and on-line experiments to study the basic properties of the gas cell as well as of the KISS. We successfully extracted the laser-ionized stable 56Fe (direct implantation of a 56Fe beam into the gas cell) atoms and 198Pt (emitted from the 198Pt target by elastic scattering with a 136Xe beam) atoms from the KISS during the commissioning on-line experiments. We furthermore extracted laser-ionized unstable 199Pt atoms and confirmed that the measured half-life was in good agreement with the reported value.

  8. Recent developments in production of radioactive ion beams with the selective laser ion source at the on-line isotope separator ISOLDE

    NASA Astrophysics Data System (ADS)

    Catherall, R.; Fedosseev, V. N.; Köster, U.; Lettry, J.; Suberlucq, G.; Marsh, B. A.; Tengborn, E.

    2004-05-01

    The resonance ionization laser ion source (RILIS) of the ISOLDE on-line isotope separation facility is based on the method of laser stepwise resonance ionization of atoms in a hot metal cavity. The atomic selectivity of the RILIS compliments the mass selection process of the ISOLDE separator magnets to provide beams of a chosen isotope with greatly reduced isobaric contamination. Using a system of dye lasers pumped by copper vapor lasers, ion beams of 22 elements have been generated at ISOLDE with ionization efficiencies in the range of 0.5%-30%. As part of the ongoing RILIS development, recent off-line resonance ionization spectroscopy studies have determined the optimal three-step ionization schemes for yttrium, scandium, and antimony.

  9. The selective and efficient laser ion source and trap project LIST for on-line production of exotic nuclides

    SciTech Connect

    Wendt, K.; Gottwald, T.; Hanstorp, D.; Mattolat, C.; Raeder, S.; Rothe, S.; Schwellnus, F.; Havener, Charles C; Lassen, J.; Liu, Yuan

    2010-01-01

    Laser ion sources based on resonant excitation and ionization of atoms are well-established tools for selective and efficient production of radioactive ion beams. A recent trend is the complementary installation of reliable state-of-theart all solid-state Ti:Sapphire laser systems. To date, 35 elements of the Periodic Table are available at laser ion sources by using these novel laser systems, which complements the overall accessibility to 54 elements including use of traditional dye lasers. Recent progress in the field concerns the identification of suitable optical excitation schemes for Ti:Sapphire laser excitation as well as technical developments of the source in respect to geometry, cavity material as well as by incorporation of an ion guide system in the form of the laser ion source trap LIST.

  10. Practical experience with on-line ion chromatography

    SciTech Connect

    Lynch, G.J.

    1991-12-31

    Bettis is heavily involved in on-line ion chromatography and has gained much experience with the systems. This paper serves to pass that experience along to any users, current or prospective, that are interested in the systems. On-line IC is extremely dynamic and the developments over the past few years have helped to produce systems that can provide technical and productivity improvements. The potential uses of the systems are only beginning to be tapped. It is the information provided herein maybe useful to any interested in on-line ion chromatography.

  11. On-line composition with laser-based techniques

    SciTech Connect

    Finch, F.T.; Hartford, A. Jr.

    1982-01-01

    Current methods for determining the composition of coal gasification streams generally involve sampling, some treatment, and inherent delay times prior to analysis. Optical instrumentation, on the other hand, provides the potential for on-line, rapid-response monitoring of gasifier streams. Among the optical technques that appear quite promising for this application are coherent anti-Stokes Raman scattering (CARS), laser-induced breakdown spectroscopy (LIBS), Fourier transform infrared spectroscopy (FTIR), laser-induced fluorescence (LIF), and synchronous detection of laser-induced fluorescence (SDLIF).

  12. Laser Ultrasonic System for On-Line Steel Tube Gauging

    NASA Astrophysics Data System (ADS)

    Monchalin, Jean-Pierre; Choquet, Marc; Padioleau, Christian; Néron, Christian; Lévesque, Daniel; Blouin, Alain; Corbeil, Christian; Talbot, Richard; Bendada, Abdelhakim; Lamontagne, Mario; Kolarik, Robert V.; Jeskey, Gerald V.; Dominik, Erich D.; Duly, Larry J.; Samblanet, Kenneth J.; Agger, Steven E.; Roush, Kenneth J.; Mester, Michael L.

    2003-03-01

    A laser-ultrasonic system has been installed on a seamless tubing production line of The Timken Company and is being used to measure on-line the wall thickness of tubes during processing. The seamless process consists essentially in forcing a mandrel through a hot cylindrical billet in rotation and typically results in fairly large wall thickness variations that should be minimized and controlled to respect specifications. The system includes a Q-switched Nd-YAG laser for generation of ultrasound by ablation, a long pulse very stable Nd-YAG laser for detection coupled to a confocal Fabry-Perot interferometer, a pyrometer to measure tube temperature and two laser Doppler velocimeters to measure the coordinates of the probing location at the tube surface. The laser, data acquisition and processing units are housed in a cabin off line and connected to a front coupling head located over the passing tube by optical fibers. The system has been integrated into the plant computer network and provides in real time thickness data to the plant operators. It allow much faster mill setups, has been used since its deployment for inspecting more than 100,000 tubes and has demonstrated very significant savings.

  13. Versatile Ion-polarized Techniques On-line (VITO) experiment at ISOLDE-CERN

    NASA Astrophysics Data System (ADS)

    Stachura, M.; Gottberg, A.; Johnston, K.; Bissell, M. L.; Garcia Ruiz, R. F.; Martins Correia, J.; Granadeiro Costa, A. R.; Dehn, M.; Deicher, M.; Fenta, A.; Hemmingsen, L.; Mølholt, T. E.; Munch, M.; Neyens, G.; Pallada, S.; Silva, M. R.; Zakoucky, D.

    2016-06-01

    The VITO (Versatile Ion-polarized Techniques Online) project is a new experimental setup at the ISOLDE facility at CERN. VITO is a dedicated beam line for producing laser-induced spin-polarized beams of both, atoms and ions, and it has been commissioned in response to the continuously growing demand for the use of spin-polarized beams. The new VITO beam line is a modification of the formerly existing ultra-high vacuum beam line, connecting ASPIC (Apparatus for Surface Physics and Interfaces at CERN), and it has been under construction since the beginning of 2014. Once fully commissioned, VITO will open up numerous possibilities for carrying out multidisciplinary experiments in the areas of nuclear and solid state physics, fundamental interaction physics and biophysics. In its final stage the VITO beam line will provide three fully independent experimental stations: UHV chamber for material science applications, a β-asymmetry station where highly-polarized ions will be available, and a central open-end station suitable for travelling experiments. The VITO beam line will operate in two different modes providing either beams of spin-polarized atoms or ions, or non-polarized ion beams to all three end stations operating from 10-10 mbar to 50 mbar. Recent experimental campaigns with stable and radioactive beams have allowed for testing VITO's constituent parts and have demonstrated 96% of ion beam transmission to the collection chamber installed on the central station. The first experimental results obtained with on-line Perturbed Angular Correlation (PAC) spectroscopy using 68mCu ion-beams will be briefly discussed.

  14. On-Line Wavelength Calibration of Pulsed Laser for CO2 Differential Absorption LIDAR

    NASA Astrophysics Data System (ADS)

    Xiang, Chengzhi; Ma, Xin; Han, Ge; Liang, Ailin; Gong, Wei

    2016-06-01

    Differential absorption lidar (DIAL) remote sensing is a promising technology for atmospheric CO2 detection. However, stringent wavelength accuracy and stability are required in DIAL system. Accurate on-line wavelength calibration is a crucial procedure for retrieving atmospheric CO2 concentration using the DIAL, particularly when pulsed lasers are adopted in the system. Large fluctuations in the intensities of a pulsed laser pose a great challenge for accurate on-line wavelength calibration. In this paper, a wavelength calibration strategy based on multi-wavelength scanning (MWS) was proposed for accurate on-line wavelength calibration of a pulsed laser for CO2 detection. The MWS conducted segmented sampling across the CO2 absorption line with appropriate number of points and range of widths by using a tunable laser. Complete absorption line of CO2 can be obtained through a curve fitting. Then, the on-line wavelength can be easily found at the peak of the absorption line. Furthermore, another algorithm called the energy matching was introduced in the MWS to eliminate the backlash error of tunable lasers during the process of on-line wavelength calibration. Finally, a series of tests was conducted to elevate the calibration precision of MWS. Analysis of tests demonstrated that the MWS proposed in this paper could calibrate the on-line wavelength of pulsed laser accurately and steadily.

  15. An ion guide laser ion source for isobar-suppressed rare isotope beams.

    PubMed

    Raeder, Sebastian; Heggen, Henning; Lassen, Jens; Ames, Friedhelm; Bishop, Daryl; Bricault, Pierre; Kunz, Peter; Mjøs, Anders; Teigelhöfer, Andrea

    2014-03-01

    Modern experiments at isotope separator on-line (ISOL) facilities like ISAC at TRIUMF often depend critically on the purity of the delivered rare isotope beams. Therefore, highly selective ion sources are essential. This article presents the development and successful on-line operation of an ion guide laser ion source (IG-LIS) for the production of ion beams free of isobaric contamination. Thermionic ions from the hot ISOL target are suppressed by an electrostatic potential barrier, while neutral radio nuclides effusing out are resonantly ionized by laser radiation within a quadrupole ion guide behind this barrier. The IG-LIS was developed through detailed thermal and ion optics simulation studies and off-line tests with stable isotopes. In a first on-line run with a SiC target a suppression of surface-ionized Na contaminants in the ion beam of up to six orders of magnitude was demonstrated. PMID:24689577

  16. An ion guide laser ion source for isobar-suppressed rare isotope beams

    SciTech Connect

    Raeder, Sebastian Ames, Friedhelm; Bishop, Daryl; Bricault, Pierre; Kunz, Peter; Mjøs, Anders; Heggen, Henning; Institute of Applied Physics, TU Darmstadt, Schlossgartenstr. 7, 64289 Darmstadt ; Lassen, Jens Teigelhöfer, Andrea; Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2

    2014-03-15

    Modern experiments at isotope separator on-line (ISOL) facilities like ISAC at TRIUMF often depend critically on the purity of the delivered rare isotope beams. Therefore, highly selective ion sources are essential. This article presents the development and successful on-line operation of an ion guide laser ion source (IG-LIS) for the production of ion beams free of isobaric contamination. Thermionic ions from the hot ISOL target are suppressed by an electrostatic potential barrier, while neutral radio nuclides effusing out are resonantly ionized by laser radiation within a quadrupole ion guide behind this barrier. The IG-LIS was developed through detailed thermal and ion optics simulation studies and off-line tests with stable isotopes. In a first on-line run with a SiC target a suppression of surface-ionized Na contaminants in the ion beam of up to six orders of magnitude was demonstrated.

  17. Resonant Ionization Laser Ion Source Project at TRIUMF

    NASA Astrophysics Data System (ADS)

    Lassen, J.; Bricault, P.; Dombsky, M.; Lavoie, J. P.; Geppert, Ch.; Wendt, K.

    2005-04-01

    Resonant laser excitation and ionisation is one of the most successful tools for the selective production of radioactive ion beams (RIB) at on-line mass separator facilities. TRIUMF plans to augment the current ion sources with a resonant ionisation laser ion source (RILIS), to use the high production yields from the target, as shown by the delivery of 3*104/s 11Li ions from a standard target ion source with surface ionisation. The development and installation of TRIUMF's RILIS (TRILIS) is necessary to provide beams of short lived isotopes that conventional ion sources could not produce in sufficient intensity and purity for nuclear-, and nuclear astrophysics- experiments. A laser system consisting of three tunable titanium sapphire (TiSa) lasers with frequency doubling and tripling was employed to demonstrate first off-line resonance ionisation of Ga, and is being installed for first on-line test and a run on 62Ga in December 2004.

  18. An On-line Monitor for Fluence Distributions and Imaging of Scanning Ion Beams

    NASA Astrophysics Data System (ADS)

    Pautard, C.; Balanzat, E.; Ban, G.; Batin, E.; Carniol, B.; Colin, J.; Cussol, D.; Etasse, D.; Fontbonne, J. M.; Labalme, M.; Laborie, P.

    2007-11-01

    Clinical applications of hadron beams have generated a wide development of radiobiology experiments, especially at GANIL (Grand Accélérateur National d'Ions Lourds), an ion accelerator in Caen. Biological samples are irradiated with ions in order to observe the induced biological effects. As these observations have to be related to the fluence distribution, an on-line beam monitor has been developed in order to measure and image fluence maps of each biological sample irradiation with a 1% uncertainty. This beam monitor has been tested with different types of ions at several energies and for intensities from 104 to 109 ions per second.

  19. A commercial tunable diode laser (TDL) system for on-line remote measurements of automobile emissions

    NASA Astrophysics Data System (ADS)

    Weber, Konradin; Ropertz, Alexander; Schwabe, Thomas; Fischer, Christian; van Haren, Gunther

    2004-11-01

    An innovative tunable diode laser (TDL) measurement system has been used for the on-line estimation of emissions of cars, driving through the measurement beam of the system. This paper describes the measurement principle and gives first measurement results, taken for different types of cars.

  20. A resonant ionization laser ion source at ORNL

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Stracener, D. W.

    2016-06-01

    Multi-step resonance laser ionization has become an essential tool for the production of isobarically pure radioactive ion beams at the isotope separator on-line (ISOL) facilities around the world. A resonant ionization laser ion source (RILIS) has been developed for the former Holifield Radioactive Ion Beam Facility (HRIBF) of Oak Ridge National Laboratory. The RILIS employs a hot-cavity ion source and a laser system featuring three grating-tuned and individually pumped Ti:Sapphire lasers, especially designed for stable and simple operation. The RILIS has been installed at the second ISOL production platform of former HRIBF and has successfully provided beams of exotic neutron-rich Ga isotopes for beta decay studies. This paper reports the features, advantages, limitations, and on-line and off-line performance of the RILIS.

  1. Progress of resonant ionization laser ion source development at GANIL

    SciTech Connect

    Henares, J. L. Huguet, Y.; Lecesne, N.; Leroy, R.; Osmond, B.; Sjödin, A. M.; Kron, T.; Schneider, F.; Wendt, K.

    2014-02-15

    SPIRAL2 (Système de Production d’Ions Radioactifs Accélérés en Ligne) is a research facility under construction at GANIL (Grand Accélérateur National d’Ions Lourds) for the production of radioactive ion beams by isotope separation on-line methods and low-energy in-flight techniques. A resonant ionization laser ion source will be one of the main techniques to produce the radioactive ion beams. GISELE (GANIL Ion Source using Electron Laser Excitation) is a test bench developed to study a fully operational laser ion source available for Day 1 operations at SPIRAL2 Phase 2. The aim of this project is to find the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results about the new ion source geometry will be presented.

  2. High temperature ion source for an on-line isotope separator

    DOEpatents

    Mlekodaj, Ronald L.

    1979-01-01

    A reduced size ion source for on-line use with a cyclotron heavy-ion beam is provided. A sixfold reduction in source volume while operating with similar input power levels results in a 2000.degree. C. operating temperature. A combined target/window normally provides the reaction products for ionization while isolating the ion source plasma from the cyclotron beam line vacuum. A graphite felt catcher stops the recoiling reaction products and releases them into the plasma through diffusion and evaporation. Other target arrangements are also possible. A twenty-four hour lifetime of unattended operation is achieved, and a wider range of elements can be studied than was heretofore possible.

  3. On-Line Estimation of Laser-Drilled Hole Depth Using a Machine Vision Method

    PubMed Central

    Ho, Chao-Ching; He, Jun-Jia; Liao, Te-Ying

    2012-01-01

    The paper presents a novel method for monitoring and estimating the depth of a laser-drilled hole using machine vision. Through on-line image acquisition and analysis in laser machining processes, we could simultaneously obtain correlations between the machining processes and analyzed images. Based on the machine vision method, the depths of laser-machined holes could be estimated in real time. Therefore, a low cost on-line inspection system is developed to increase productivity. All of the processing work was performed in air under standard atmospheric conditions and gas assist was used. A correlation between the cumulative size of the laser-induced plasma region and the depth of the hole is presented. The result indicates that the estimated depths of the laser-drilled holes were a linear function of the cumulative plasma size, with a high degree of confidence. This research provides a novel machine vision-based method for estimating the depths of laser-drilled holes in real time. PMID:23112593

  4. A hot cavity laser ion source at IGISOL

    NASA Astrophysics Data System (ADS)

    Reponen, M.; Kessler, T.; Moore, I. D.; Rothe, S.; Äystö, J.

    2009-12-01

    A development program is underway at the IGISOL (Ion Guide Isotope Separator On-Line) facility, University of Jyväskylä, to efficiently and selectively produce low-energy radioactive ion beams of silver isotopes and isomers, with a particular interest in N = Z 94Ag . A hot cavity ion source has been installed, based on the FEBIAD (Forced Electron Beam Induced Arc Discharge) technique, combined with a titanium:sapphire laser system for selective laser ionization. The silver recoils produced via the heavy-ion fusion-evaporation reaction, 40Ca(58Ni, p3n)94Ag , are stopped in a graphite catcher, diffused, extracted and subsequently ionized using a three-step laser ionization scheme. The performance of the different components of the hot cavity laser ion source is discussed and initial results using stable 107, 109Ag are presented.

  5. Development of a laser-scattering-based probe for on-line measurement of surface roughness.

    PubMed

    Wang, Shihua; Tian, Yunhui; Tay, Cho Jui; Quan, Chenggen

    2003-03-01

    The design and properties of an optical probe for on-line measurement of surface roughness are discussed. Based on light scattering, a probe that consists of a laser diode, a measuring lens, and a linear photodiode array was designed to detect surface roughness, in which the light scattered from a test surface at a relatively large scattering angle phi (=28 degrees) can be collected to enhance measuring range and repeatability. A coaxial design that incorporates a dual-laser probe and compressed air makes the proposed system insensitive to the position of the test surface and to surface conditions such as the presence of debris, vibration, and lubricants that result from machining. The results from measurements of several sets of specimens have demonstrated the feasibility of measuring surface roughness by using light scattering. On-line measurement on a diamond-turning lathe has shown that the proposed technique is stable and compact enough to be applicable to on-line measurement of surface roughness of an engineering surface. PMID:12638888

  6. An effective method for on-line corrections of two-axes laser mount

    NASA Astrophysics Data System (ADS)

    Lala, P.; Pivo, K.

    A numerical technique for correcting the automatic laser tracking of low-altitude satellites for the effects of atmospheric drag on the satellite motion is proposed. The approximation method is based on geocentric rather than topocentric parameters and is simple enough to be implemented on a desk-top computer for on-line correction of both along-track and cross-track deviations by entering the error in the initial time. The results of numerical simulations for B-1300 and GEOS A are presented in a table, and the suitability of the method for on-line computer control of the two-axis azimuthal mount used at Ondrejov Observatory is indicated.

  7. On-line Raman spectroscopy of calcite and malachite during irradiation with swift heavy ions

    NASA Astrophysics Data System (ADS)

    Dedera, Sebastian; Burchard, Michael; Glasmacher, Ulrich A.; Schöppner, Nicole; Trautmann, Christina; Severin, Daniel; Romanenko, Anton; Hubert, Christian

    2015-12-01

    A new on-line Raman System, which was installed at the M3-beamline at the UNILAC, GSI Helmholtzzentrum für Schwerionenforschung Darmstadt was used for first "in situ" spectroscopic measurements. Calcite and malachite samples were irradiated in steps between 1 × 109 and 1 × 1012 ions/cm2 with Au ions (calcite) and Xe ions (malachite) at an energy of 4.8 MeV/u. After irradiation, calcite revealed a new Raman band at 437 cm-1 and change of the full width at half maximum for the 1087 cm-1 Raman band. The Raman bands of malachite change significantly with increasing fluence. Up to a fluence of 7 × 1010 ions/cm2, all existing bands decrease in intensity. Between 8 × 1010 and 1 × 1011 ions/cm2 a broad Cu2O band between 110 and 220 cm-1 occurs, which superimposes the pre-existing Raman bands. Additionally, a new broad band between 1000 and 1750 cm-1 is formed, which is interpreted as a carbon coating. In contrast to the Cu2O band, the carbon band vanished when further irradiating the sample. The installations as well as first in situ measurements at room temperature are presented.

  8. The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

    SciTech Connect

    Ma, Y. Cui, B.; Ma, R.; Tang, B.; Chen, L.; Huang, Q.; Jiang, W.

    2014-02-15

    The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will be installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.

  9. On-line measurement of wavefront aberration on optics caused by intense lasers

    NASA Astrophysics Data System (ADS)

    Xu, Zuodong; Liu, Fuhua; Jiang, Chang; Wang, Fei; Shao, Bibo; Ji, Yunfeng

    2015-05-01

    It is presented that the thermally induced transmitted wavefront aberration of a high-reflectivity sampling mirror was detected on line using a Shack-Hartmann wavefront sensor (SHWS) in the beam quality measurement of an intense laser. As a result of heat absorption in the sampling mirror with active aperture of 120 mm, thermally induced wavefront aberration emerged when the mirror was exposed to high laser intensity of several kilowatts per centimeter square. Time-dependent wavefront aberration curves were acquired, and the transmitted wavefronts were reconstructed based on Zernike mode reconstruction theory. The experimental results indicate that the magnitude of the dynamic transmitted wavefront aberration increases gradually with the growing heat deposit during laser irradiation. The maximum of wavefront aberration observed after irradiation for 5 seconds reaches 0.11 μm of root-mean-square value. After further analysis, the experimental results of dynamic aberration can be applied in modifications for the measurement results of intense laser beam quality or tests for the thermal stability of optics used in the intense laser systems.

  10. Application of laser ultrasonic method for on-line monitoring of friction stir spot welding process.

    PubMed

    Zhang, Kuanshuang; Zhou, Zhenggan; Zhou, Jianghua

    2015-09-01

    Application of a laser ultrasonic method is developed for on-line monitoring of the friction stir spot welding (FSSW) process. Based on the technology of FSSW, laser-generated ultrasonic waves in a good weld and nonweld area are simulated by a finite element method. The reflected and transmitted waves are analyzed to disclose the properties of the welded interface. The noncontact-laser ultrasonic-inspection system was established to verify the numerical results. The reflected waves in the good-weld and nonweld area can be distinguished by time-of-flight. The transmitted waves evidently attenuate in the nonweld area in contrast to signal amplitude in the good weld area because of interfacial impedance difference. Laser ultrasonic C-scan images can sufficiently evaluate the intrinsic character of the weld area in comparison with traditional water-immersion ultrasonic testing results. The research results confirm that laser ultrasonics would be an effective method to realize the characterization of FSSW defects. PMID:26368866

  11. The DCU laser ion source.

    PubMed

    Yeates, P; Costello, J T; Kennedy, E T

    2010-04-01

    Laser ion sources are used to generate and deliver highly charged ions of various masses and energies. We present details on the design and basic parameters of the DCU laser ion source (LIS). The theoretical aspects of a high voltage (HV) linear LIS are presented and the main issues surrounding laser-plasma formation, ion extraction and modeling of beam transport in relation to the operation of a LIS are detailed. A range of laser power densities (I approximately 10(8)-10(11) W cm(-2)) and fluences (F=0.1-3.9 kJ cm(-2)) from a Q-switched ruby laser (full-width half-maximum pulse duration approximately 35 ns, lambda=694 nm) were used to generate a copper plasma. In "basic operating mode," laser generated plasma ions are electrostatically accelerated using a dc HV bias (5-18 kV). A traditional einzel electrostatic lens system is utilized to transport and collimate the extracted ion beam for detection via a Faraday cup. Peak currents of up to I approximately 600 microA for Cu(+) to Cu(3+) ions were recorded. The maximum collected charge reached 94 pC (Cu(2+)). Hydrodynamic simulations and ion probe diagnostics were used to study the plasma plume within the extraction gap. The system measured performance and electrodynamic simulations indicated that the use of a short field-free (L=48 mm) region results in rapid expansion of the injected ion beam in the drift tube. This severely limits the efficiency of the electrostatic lens system and consequently the sources performance. Simulations of ion beam dynamics in a "continuous einzel array" were performed and experimentally verified to counter the strong space-charge force present in the ion beam which results from plasma extraction close to the target surface. Ion beam acceleration and injection thus occur at "high pressure." In "enhanced operating mode," peak currents of 3.26 mA (Cu(2+)) were recorded. The collected currents of more highly charged ions (Cu(4+)-Cu(6+)) increased considerably in this mode of operation

  12. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry.

    PubMed

    Serafini, S; Paone, N; Castellini, P

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control. PMID:24387408

  13. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Serafini, S.; Paone, N.; Castellini, P.

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  14. Laser ultrasonic system for on-line steel tube gauging and process control

    NASA Astrophysics Data System (ADS)

    Levesque, Daniel; Choquet, Marc; Padioleau, Christian; Neron, Christian; Corbeil, Christian; Talbot, Richard; Bendada, Abdelhakim; Monchalin, Jean-Pierre; Kolarik, Robert V., II; Jeskey, Gerald V.

    2002-11-01

    A laser ultrasonic system has been installed on a seamless tubing production line at The Timken Company and is being used to measure on-line the wall thickness of tubes during processing. The seamless process consists essentially in forcing a mandrel through a hot cylindrical billet in rotation and results in wall thickness variations that should be minimized and controlled to respect specifications. The system includes a Q-switched Nd-YAG laser for the generation of ultrasound by ablation, a long pulse very stable Nd-YAG laser for detection coupled to a confocal Fabry-Perot interferometer. The lasers, data acquisition, and processing units are housed in a cabin off-line and connected to a front coupling head located over the passing tube by optical fibers. The system also includes a fiber-coupled pyrometer to measure tube temperature profile and two fiber-coupled optical velocimeters to measure the coordinates at the probing location on the surface of the passing, rotating hot tube. During the presentation further details of the system will be disclosed, as well as typical results and examples of its diagnostic capability. [Work partially supported by Department of Energy under Award No. DE-FC07-99ID 13651.

  15. Resonant Ionization Laser Ion Source for Radioactive Ion Beams

    SciTech Connect

    Liu, Yuan; Beene, James R; Havener, Charles C; Vane, C Randy; Gottwald, T.; Wendt, K.; Mattolat, C.; Lassen, J.

    2009-01-01

    A resonant ionization laser ion source based on all-solid-state, tunable Ti:Sapphire lasers is being developed for the production of pure radioactive ion beams. It consists of a hot-cavity ion source and three pulsed Ti:Sapphire lasers operating at a 10 kHz pulse repetition rate. Spectroscopic studies are being conducted to develop ionization schemes that lead to ionizing an excited atom through an auto-ionization or a Rydberg state for numerous elements of interest. Three-photon resonant ionization of 12 elements has been recently demonstrated. The overall efficiency of the laser ion source measured for some of these elements ranges from 1 to 40%. The results indicate that Ti:Sapphire lasers could be well suited for laser ion source applications. The time structures of the ions produced by the pulsed lasers are investigated. The information may help to improve the laser ion source performance.

  16. The ion-channel laser

    SciTech Connect

    Whittum, D.H.; Sessler, A.M. ); Dawson, J.M. . Dept. of Physics)

    1990-01-01

    A relativistic electron beam propagating through a plasma in the ion-focused regime exhibits an electromagnetic instability at a resonant frequency {omega} {approximately} 2{gamma}{sup 2} {omega}{sub {beta}}. Growth is enhanced by optical guiding in the ion channel, which acts as dielectric waveguide, with fiber parameter V {approximately} 2 (I/I{sub A}){sup 1/2}. A 1-D theory for such an ion-channel laser'' is formulated, scaling laws are derived and numerical examples are given. Possible experimental evidence is noted. 23 refs., 1 fig., 1 tab.

  17. Laser driven ion accelerator

    DOEpatents

    Tajima, Toshiki

    2006-04-18

    A system and method of accelerating ions in an accelerator to optimize the energy produced by a light source. Several parameters may be controlled in constructing a target used in the accelerator system to adjust performance of the accelerator system. These parameters include the material, thickness, geometry and surface of the target.

  18. Laser driven ion accelerator

    DOEpatents

    Tajima, Toshiki

    2005-06-14

    A system and method of accelerating ions in an accelerator to optimize the energy produced by a light source. Several parameters may be controlled in constructing a target used in the accelerator system to adjust performance of the accelerator system. These parameters include the material, thickness, geometry and surface of the target.

  19. Flash pyrolysis of coal by an argon ion laser

    SciTech Connect

    Thomsen, M.S.; Egsgaard, H.

    1994-12-31

    A novel approach to laser induced pyrolysis of coal by using the visible blue-green emission from an argon ion laser is presented. The gaseous pyrolysis products are identified by on-line gas chromatography/mass spectrometry (GC/MS). Five different subbituminous to bituminous coals have been studied and results for the low-molecular weight hydrocarbons up to C{sub 3} are discussed. Mechanisms for the formation of the unsaturated hydrocarbons, ethylene and acetylene, during laser pyrolysis of coal have been disclosed utilizing deuterium as a buffer gas in the pyrolysis cell.

  20. A novel method to measure wheelset parameters based on laser displacement sensor on line

    NASA Astrophysics Data System (ADS)

    Zhang, Zhi-feng; Su, Yu-ling; Gao, Zhan; Wang, Guang-yan; Ren, Yu-fen; Jiang, Feng-chun

    2010-11-01

    The geometric parameters of wheelsets, such as flange thickness, and rim width, and rim inside distance, are key parameters that influence the wheel-rail contact. The online measurement techniques of these parameters are important to ensure the safety of train vehicle and increase the reliability and efficiency of maintaining. The paper purposed the measurement system based on the optoelectronic techniques. The measuring system is composed of the trigger sensor and the laser displacement sensors fixed on the rails and the system can measure the wheelset's parameters when trains pass through. The measuring results are improved by the wavelet analysis denoised. The average value difference is between 0-0.3mm comparing the system and the manual that shows two methods are coincided. When trains pass through the measuring system under the speed of 10km/h, measuring results shows that the system can meet with the measuring requirement on line.

  1. On-line monitoring of one-step laser fabrication of micro-optical components.

    PubMed

    Juliá, J E; Soriano, J C

    2001-07-01

    The use of an on-line monitoring method based on photoelasticity techniques for the fabrication of micro-optical components by means of controlled laser heating is described. From this description it is possible to show in real time the mechanical stresses that form the microelement. A new parameter, stressed area, is introduced that quantifies the stresses of a microelement during its fabrication, facilitating a deeper understanding of the physical phenomena involved in the process as well as being a useful test of quality. It also permits the stress produced in the manufacturing process and the optical properties of the final microelement to be correlated. The results for several microlenses monitored with this technique are presented. PMID:11958263

  2. On-line wavelength calibration of pulsed laser for CO2 DIAL sensing

    NASA Astrophysics Data System (ADS)

    Han, Ge; Gong, Wei; Lin, Hong; Ma, Xin; Xiang, Chengzhi

    2014-12-01

    Accurate on-line wavelength calibration is a crucial procedure for sensing atmospheric CO2 using the DIAL technique. Drastic fluctuations in the intensity of a pulsed laser pose a great challenge for accurate on-line wavelength determination and stabilization, resulting in CO2 retrievals lacking the desired accuracy for global climate change and carbon cycle research. To tackle this problem, a two-stage wavelength calibration method based on Voigt fitting was proposed in this work. Simulation analysis demonstrated that the proposed method is superior to the conventional method and provides wavelength calibration results with an accuracy of 0.1 pm when the noise level does not exceed than 5 %. This conclusion was confirmed through experiments with real signals. Furthermore, simulation analysis revealed that the proposed method could yield results with an accuracy of 0.1 pm by increasing the number of sample points, even for signals with noise levels of up to 20 %. This is a promising feature that could facilitate the development of DIAL systems without gas cells.

  3. A novel health indicator for on-line lithium-ion batteries remaining useful life prediction

    NASA Astrophysics Data System (ADS)

    Zhou, Yapeng; Huang, Miaohua; Chen, Yupu; Tao, Ye

    2016-07-01

    Prediction of lithium-ion batteries remaining useful life (RUL) plays an important role in an intelligent battery management system. The capacity and internal resistance are often used as the batteries health indicator (HI) for quantifying degradation and predicting RUL. However, on-line measurement of capacity and internal resistance are hardly realizable due to the not fully charged and discharged condition and the extremely expensive cost, respectively. Therefore, there is a great need to find an optional way to deal with this plight. In this work, a novel HI is extracted from the operating parameters of lithium-ion batteries for degradation modeling and RUL prediction. Moreover, Box-Cox transformation is employed to improve HI performance. Then Pearson and Spearman correlation analyses are utilized to evaluate the similarity between real capacity and the estimated capacity derived from the HI. Next, both simple statistical regression technique and optimized relevance vector machine are employed to predict the RUL based on the presented HI. The correlation analyses and prediction results show the efficiency and effectiveness of the proposed HI for battery degradation modeling and RUL prediction.

  4. Quality control agent: Self-adaptive laser vibrometry for on-line diagnostics

    NASA Astrophysics Data System (ADS)

    Serafini, S.; Paone, N.; Castellini, P.

    2012-06-01

    It is presented the development of a self-adaptive diagnostic system based on laser vibrometry for production line quality control. The vibration measurement system consists of a laser Doppler vibrometer, equipped with scanning mirrors and a smart camera, which implements self-adaptivity for compensating target mis-positioning under guidance by a vision system and for the achievement of the best condition for measurement by optimizing the Doppler signal level. This system is designed as a Quality Control Agent (QCA) and it is part of a Multi Agent System (MAS) that supervises all the production line. The QCA behavior is defined so to perform a minimization of measurement uncertainty during the on line tests; for this purpose the QCA exhibits a self-adaptive behavior. Best measurement conditions are defined in terms of amplitude of the optical Doppler beat signal (signal quality - SQ). In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed.

  5. Laser ion source for low charge heavy ion beams

    SciTech Connect

    Okamura,M.; Pikin, A.; Zajic, V.; Kanesue, T.; Tamura, J.

    2008-08-03

    For heavy ion inertial fusion application, a combination of a laser ion source and direct plasma injection scheme into an RFQ is proposed. The combination might provide more than 100 mA of singly charged heavy ion beam from a single laser shot. A planned feasibility test with moderate current is also discussed.

  6. TITAN: An ion trap facility for on-line mass measurement experiments

    NASA Astrophysics Data System (ADS)

    Kwiatkowski, A. A.; Andreoiu, C.; Bale, J. C.; Brunner, T.; Chaudhuri, A.; Chowdhury, U.; Delheij, P.; Ettenauer, S.; Frekers, D.; Gallant, A. T.; Grossheim, A.; Gwinner, G.; Jang, F.; Lennarz, A.; Ma, T.; Mané, E.; Pearson, M. R.; Schultz, B. E.; Simon, M. C.; Simon, V. V.; Dilling, J.

    2014-01-01

    Precision determinations of ground state or even isomeric state masses reveal fingerprints of nuclear structure. In particular, at the limits of existence for very neutron-rich or -deficient isotopes, one can extract detailed information about nuclear structure from separation energies or binding energies. Mass measurements are important to uncover new phenomena, to test new theoretical predictions, or to refine model approaches. For example, the N = 28 shell has proven more stable than previously expected; however, the predicted new "magic" number at N = 34 in the K and Ca isotopes has yet to be confirmed experimentally. For these neutron-rich nuclei, the inclusion of three-body forces leads to significantly better predictions of the ground-state mass. Similarly, halo nuclei present an excellent application for ab-initio theory, where ground state properties, like masses and radii, test our understanding of nuclear structure. Precision mass determinations at TRIUMF are carried out with the TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) facility. It is an ion-trap setup coupled to the on-line facility ISAC. TITAN has measured masses of isotopes as short-lived as 9 ms (almost an order of magnitude shorter-lived than any other Penning trap system), and it is the only one with charge breeding capabilities, which allow us to boost the precision by almost 2 orders of magnitude. We recently made use of this feature by measuring short-lived, proton-rich Rb-isotopes, up to 74Rb while reaching the 12 + charge state, which together with other improvements led to an increase in precision by a factor 36.

  7. On Line Characterization of SiC Nanoparticles Produced by Laser Pyrolysis

    NASA Astrophysics Data System (ADS)

    Wattieaux, G.; Lecerf, P.; Meyer, L.; Boufendi, L.; Leconte, Y.; Sublemontier, O.; Herlin, N.; Asimakopoulou, A.; Tsakis, A.; Daskalos, M.; Konstandopoulos, A. G.; Ouf, F. X.

    2011-07-01

    On Line Measurements campaigns have been carried out for the first time in IRAMIS/SPAM CEA's laser gas-phase pyrolysis nanoparticles production facilities. The produced aerosol is composed of Argon and/or Helium laden with SiC nanoparticles concentrated up to ~14 mg/l. Different commercial apparatus were used for sampling, and characterisation of size, and morphology of the particles. A series of experiment is performed by IRSN with a DMS500 from Cambustion Ltd™, which gives electrical mobility equivalent diameter distribution in real time. Particles are sampled with an ejector-diluter VKL-10 from Palas™. On the same sampling line, APTL performed aerodynamic equivalent diameter mass distribution using a Nanomoudi from MSP Corp.™ and TEM post analysis, as well as post elemental analysis (EDS) after collection on TEM grid with a Thermophoretic Precipitator (TP). A previously developed model is used to obtain the aggregate morphology and primary particles sizes. In addition to these commercial or well-known techniques, a new patent-pending technique called RFPM (Radio Frequency Plasma Metrology developed by CILAS + GREMI in the frame of NANOCARA program) is tested for the first time off the lab. The principle is based on levitation of particles in plasma RF. The entire set up is a prototype, including the sampling line. Experiments showed that this technique is very promising for on line gas phase monitoring, even though future improvements are needed, especially on the direct injection of the sample in the measuring chamber. First results of size distribution on pyrolysis line were obtained: three modes of different geometric mean diameter D50 were measured. Further analysis of TEM micrographs gave insight on these three modes, they can be interpreted as primary particles, aggregated particles, and a third one which could be composed of silica oxide nanoparticles issued from the combustion of the remaining silane initiated by an air leak in the exhaust of the

  8. Optimization of a hot-cavity type resonant ionization laser ion source

    NASA Astrophysics Data System (ADS)

    Henares, J. L.; Lecesne, N.; Hijazi, L.; Bastin, B.; Kron, T.; Lassen, J.; Le Blanc, F.; Leroy, R.; Naubereit, P.; Osmond, B.; Vignet, J. L.; Wendt, K.

    2016-02-01

    Resonant Ionization Laser Ion Source (RILIS) is nowadays an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability and ability to ionize efficiently and element selectively. Grand Accélérateur National d'Ions Lourds (GANIL) Ion Source using Electron Laser Excitation (GISELE) is an off-line test bench for RILIS developed to study a fully operational resonant laser ion source at GANIL facility. The ion source body has been designed as a modular system to investigate different experimental approaches by varying the design parameters, to develop the future on-line laser ion source. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results concerning emittance and time profile development as a function of the temperature for different ion source versions will be presented.

  9. Ion production from solid state laser ion sources

    SciTech Connect

    Gottwald, T.; Havener, Charles C; Lassen, J.; Liu, Yuan; Mattolat, C.; Raeder, S.; Rothe, S.; Wendt, K.

    2010-01-01

    Laser ion sources based on resonant excitation and ionization of atoms are well-established tools for selective and efficient production of radioactive ion beams. Recent developments are focused on the use of the state-of-the-art all solid-state laser systems. To date, 35 elements of the periodic table are available from laser ion sources based on tunable Ti:sapphire lasers. Recent progress in this field regarding the establishment of suitable optical excitation schemes for Ti:sapphire lasers are reported.

  10. Ion production from solid state laser ion sources

    SciTech Connect

    Gottwald, T.; Mattolat, C.; Raeder, S.; Wendt, K.; Havener, C.; Liu, Y.; Lassen, J.; Rothe, S.

    2010-02-15

    Laser ion sources based on resonant excitation and ionization of atoms are well-established tools for selective and efficient production of radioactive ion beams. Recent developments are focused on the use of the state-of-the-art all solid-state laser systems. To date, 35 elements of the periodic table are available from laser ion sources based on tunable Ti:sapphire lasers. Recent progress in this field regarding the establishment of suitable optical excitation schemes for Ti:sapphire lasers are reported.

  11. Structural elucidation of monoterpene oxidation products by ion trap fragmentation using on-line atmospheric pressure chemical ionisation mass spectrometry in the negative ion mode.

    PubMed

    Warscheid, B; Hoffmann, T

    2001-01-01

    Based on ion trap mass spectrometry, an on-line method is described which provides valuable information on the molecular composition of structurally complex organic aerosols. The investigated aerosols were generated from the gas-phase ozonolysis of various C(10)H(16)-terpenes (alpha-pinene, beta-pinene, 3-carene, sabinene, limonene), and directly introduced into the ion source of the mass spectrometer. Negative ion chemical ionisation at atmospheric pressure (APCI(-)) enabled the detection of multifunctional carboxylic acid products by combining inherent sensitivity and molecular weight information. Sequential low-energy collision-induced product ion fragmentation experiments (MS(n)) were performed in order to elucidate characteristic decomposition pathways of the compounds. Dicarboxylic acids, oxocarboxylic acids and hydroxyketocarboxylic acid products could be clearly distinguished by multistage on-line MS. Furthermore, sabinonic acid and two C(9)-ether compounds were tentatively identified for the first time by applying on-line APCI(-)-MS(n). PMID:11746892

  12. A test stand for off-line laser ion source development at TRIUMF

    SciTech Connect

    Lavoie, J. P.; Li, R.; Bricault, P.; Lassen, J.; Chachkova, O.; Teigelhoefer, A.

    2013-01-15

    A test stand for ion source development and laser resonance ionization spectroscopy was built and commissioned at TRIUMF. The test stand is needed to develop efficient ion sources that can function reliably in the hostile, high temperature, high radiation environment of TRIUMF's isotope separator on-line (ISOL) production target ion source. In addition, it enables laser resonance ionization spectroscopy to develop laser excitation schemes suitable for the solid-state laser systems used with TRIUMF's resonant ionization laser ion source . Also, it allows for possible improvement of current ion sources and validation of new designs. The test stand employs a copy of the ion optics used on-line, so that results can be transferred directly to radioactive ion beam production. Due to space restrictions and the need for rapid mass scans, a quadrupole mass spectrometer is used as a mass separator. One of the first experiments conducted on the laser ion source test stand (LIS STAND) was resonant ionization spectroscopy of gallium to improve on the ionization scheme previously used on-line, so that low yield isotopes (e.g., {sup 62}Ga) become available for experiments. Different Rydberg series in gallium were observed and autoionizing states were searched for. The overall LIS STAND system performance, characteristics, and the first resonant ionization spectroscopy are described.

  13. Laser ion source with solenoid field

    SciTech Connect

    Kanesue, Takeshi Okamura, Masahiro; Fuwa, Yasuhiro; Kondo, Kotaro

    2014-11-10

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. The laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 10{sup 11}, which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.

  14. Laser ion source with solenoid field

    SciTech Connect

    Kanesue, Takeshi; Fuwa, Yasuhiro; Kondo, Kotaro; Okamura, Masahiro

    2014-11-12

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. In this study, the laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 1011, which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.

  15. Laser ion source with solenoid field

    DOE PAGESBeta

    Kanesue, Takeshi; Fuwa, Yasuhiro; Kondo, Kotaro; Okamura, Masahiro

    2014-11-12

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. In this study, the laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 1011, whichmore » was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.« less

  16. Laser ion source with solenoid field

    NASA Astrophysics Data System (ADS)

    Kanesue, Takeshi; Fuwa, Yasuhiro; Kondo, Kotaro; Okamura, Masahiro

    2014-11-01

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. The laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 1011, which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.

  17. Laser Ion Source Development at HRIBF

    SciTech Connect

    Liu, Yuan; Beene, James R; Havener, Charles C; Howe, Jane Y; Kiggans Jr, James O; Vane, C Randy; Mattolat, C.; Gottwald, T.; Wendt, K.

    2012-01-01

    This report describes the efforts made to develop a resonant-ionization laser ion source based on tunable Ti:Sapphire lasers for nuclear physics and astrophysics research at HRIBF. Three Ti:Sapphire lasers have been upgraded with individual pump lasers to eliminate laser power losses due to synchronization delays. Ionization schemes for 14 elements have been obtained. Off-line studies show that the overall efficiency of the laser ion source can be as high as 40%. TaC surface coatings have been investigated for minimizing surface and bulk trapping of the atoms of interest.

  18. Bacterial cells enhance laser driven ion acceleration

    PubMed Central

    Dalui, Malay; Kundu, M.; Trivikram, T. Madhu; Rajeev, R.; Ray, Krishanu; Krishnamurthy, M.

    2014-01-01

    Intense laser produced plasmas generate hot electrons which in turn leads to ion acceleration. Ability to generate faster ions or hotter electrons using the same laser parameters is one of the main outstanding paradigms in the intense laser-plasma physics. Here, we present a simple, albeit, unconventional target that succeeds in generating 700 keV carbon ions where conventional targets for the same laser parameters generate at most 40 keV. A few layers of micron sized bacteria coating on a polished surface increases the laser energy coupling and generates a hotter plasma which is more effective for the ion acceleration compared to the conventional polished targets. Particle-in-cell simulations show that micro-particle coated target are much more effective in ion acceleration as seen in the experiment. We envisage that the accelerated, high-energy carbon ions can be used as a source for multiple applications. PMID:25102948

  19. The Resonance Laser Ion Source at Ipn-Atlo

    NASA Astrophysics Data System (ADS)

    Li, R.; Franchoo, S.; Lau, C.; Fedosseev, V.; Goodacre, T. D.; March, B.; Flanagan, K.; Kron, T.; Wendt, K.

    2015-06-01

    Resonant Ionization Laser Ion Source (RILIS), based on the stepwise excitations of atomic transitions, offers an outstanding combination of excellent elemental selectivity and high ionization efficiency. It has become a powerful and versatile tool for generation of pure radioactive isotope beams at on-line mass separator facilities worldwide. Initiated in 2009, IPN-Orsay has installed RILIS in the Isotope Separators on-line (ISOL) system at the photofission facility ALTO, which aims to the measurements of the nuclear properties of exotic nuclei through β-γ and β-n spectroscopy, among other techniques. RILS at ALTO (RIALTO) consists of two dye lasers pumped with a 532nm 10kHz Nd:YAG laser with the wavelength extension options via frequency doubling/tripling of nonlinear crystals. Gallium and Zinc isotopic beams were successfully delivered by RIALTO starting from 2011. To develop the laser ionization scheme for different elements and test optimal operational parameters for on-line radioactive beam deliveries, an off-line reference cell has been built. The preliminary result of the first commence of the off-line reference cell will be presented in this paper.

  20. On line diagnostics and characterization of thin films deposited by laser ablation of solid oxides precursors of superconductors

    NASA Astrophysics Data System (ADS)

    Giardini-Guidoni, A.; Desimoni, E.; Salvi, A. M.; Teghil, R.; Ambrico, M.; Morone, A.; Piccirillo, S.; Snels, M.

    This work presents the analysis of composite solid targets made by laser irradiation of mixtures of simple oxides and of superconducting YBCO and BISCO. The results are discussed in relation to previous studies on laser cluster ion formation of these materials and their chemical reactivity. The films of ablated materials have been analyzed by XPS and SEM.

  1. Laser photoelectron spectroscopy of ions

    SciTech Connect

    Ellison, G.B.

    1992-01-16

    This enterprise uses photoelectron spectroscopy to study the properties of negative ions and radicals. The essence of our experiment is to cross a 0.6 keV mass-selected ion beam (M{sup {minus}}) with the output of a CW laser, {Dirac h}{omega}{sub o}. The resultant detached photoelectrons with kinetic energy, KE, are energy analyzed by means of a set of electrostatic hemispherical analyzers. Analysis of the photoelectron spectra enables us to extract molecular electron affinities, vibrational frequencies and electronic splittings of the final radical, M, as well as the relative molecular geometries of ions (M{sup {minus}}) and radicals (M). We have scrutinized the two simplest nitrenes: methylnitrene (CH{sub 3}N) and phenylnitrene (C{sub 6}H{sub 5}N). By preparing the corresponding anions, CH{sub 3}N{sup {minus}} and C{sub 6}H{sub 5}N{sup {minus}}, we have studied these nitrene biradicals. Singlet methylnitrene is especially interesting since it is formally a transition state.''

  2. Beam current controller for laser ion source

    SciTech Connect

    Okamura, Masahiro

    2014-10-28

    The present invention relates to the design and use of an ion source with a rapid beam current controller for experimental and medicinal purposes. More particularly, the present invention relates to the design and use of a laser ion source with a magnetic field applied to confine a plasma flux caused by laser ablation.

  3. On-line cation exchange for suppression of adduct formation in negative-ion electrospray mass spectrometry of nucleic acids.

    PubMed

    Huber, C G; Buchmeiser, M R

    1998-12-15

    One major difficulty in the analysis of nucleic acids by electrospray mass spectrometry is represented by the affinity of the polyanionic sugar-phosphate backbone for nonvolatile cations, especially ubiquitous sodium and potassium ions. A simple on-line sample preparation system comprising a microflow pumping system and 45 x 0.8-mm-i.d. microcolumns packed with weak or strong cation-exchange resins is described for the efficient removal of cations from nucleic acid samples. Samples were analyzed by flow injection analysis at a 3-5 microL/min flow of 10 mM triethylamine in 50% water-50% acetonitrile. After on-line desalting, mass spectra of oligonucleotides revealed no significant sodium adduct peaks. Moreover, signal-to-noise ratios were greatly enhanced compared to direct injection of the samples. Electrospray mass spectrometry with on-line sample preparation allowed accurate molecular mass determinations of picomole amounts of crude oligonucleotide preparations ranging in size from 8 to 80 nucleotides within a few minutes. The good linearity of the calibration plot (R2 = 0.9988) over at least 2 orders of magnitude and a relative standard deviation in peak areas of less than 9% permitted the sensitive quantitative measurement of oligonucleotides in a concentration range of 0.2-20 microM with selected-ion monitoring. Finally, the on-line sample preparation system was evaluated for the mass spectrometric analysis of complex oligonucleotide mixtures. PMID:9868919

  4. Ion-molecule processes in lasers

    NASA Technical Reports Server (NTRS)

    Laudenslager, J. B.

    1979-01-01

    Three classes of molecular electronic transition lasers produced by hybrid pumping of high pressure rate gas mixtures are discussed. These are (1) rare gas dimer lasers (such as excited Ar2, Kr2, and Xe2) lasing in the VUV, (2) rare gas halide lasers or excimer lasers (such as KrF, ArF, and XeCl excimers) lasing in the UV, and (3) the charge transfer molecular ion laser (such as N2/+/) lasing in the visible range. Laser excitation methods and kinetic sequences are examined for these lasers.

  5. On-line monitoring system for roller wear with axes shift compensation based on laser-linear charge coupled device

    NASA Astrophysics Data System (ADS)

    Wei, Liansuo; Guo, Yuan

    2013-04-01

    Based on the principle of laser-linear array charge-coupled device (CCD) detection technology, a high accuracy nontouch on-line system for monitoring roller wear is brought forward. The principle and composition of the laser-linear array CCD detection system and the operation process were expatiated. Aiming at the errors of the roller's axes shifting during the detection process, compensating steps were adopted from the vertical and the parallel direction to the detection surface. This effectively enhanced the accuracy of the detection system. Experiments proved that the accuracy of the system could reach the demand of the practical production process. It provides a new method for high speed, accuracy, and automatic on-line monitoring of roller wear. r shapegear array CCD detection. A simulation-software program is also compiled based on this principle. By using this program, the I/O signals's data for this system is gained and the detection curves can be drawn automatically.

  6. Ion implantation and laser annealing

    NASA Astrophysics Data System (ADS)

    Three ion implantation and laser annealing projects have been performed by ORNL through the DOE sponsored Seed Money Program. The research has contributed toward improving the characteristics of wear, hardness, and corrosion resistance of some metals and ceramics, as well as the electrical properties of semiconductors. The work has helped to spawn related research, at ORNL and elsewhere, concerning the relationships between microstructure and materials properties. ORNL research has resulted in major advances in extended life and non-corrosive artificial joints (hip and knee), high performance semiconductors, failure resistant ceramics (with potential energy applications), and solar cells. The success of the seed money projects was instrumental in the formation of ORNL's Surface Modification and Characterization Facility (SMAC). More than 60 universities and companies have participated in SMAC programs.

  7. Laser-cooled atomic ions as probes of molecular ions

    SciTech Connect

    Brown, Kenneth R.; Viteri, C. Ricardo; Clark, Craig R.; Goeders, James E.; Khanyile, Ncamiso B.; Vittorini, Grahame D.

    2015-01-22

    Trapped laser-cooled atomic ions are a new tool for understanding cold molecular ions. The atomic ions not only sympathetically cool the molecular ions to millikelvin temperatures, but the bright atomic ion fluorescence can also serve as a detector of both molecular reactions and molecular spectra. We are working towards the detection of single molecular ion spectra by sympathetic heating spectroscopy. Sympathetic heating spectroscopy uses the coupled motion of two trapped ions to measure the spectra of one ion by observing changes in the fluorescence of the other ion. Sympathetic heating spectroscopy is a generalization of quantum logic spectroscopy, but does not require ions in the motional ground state or coherent control of the ion internal states. We have recently demonstrated this technique using two isotopes of Ca{sup +} [Phys. Rev. A, 81, 043428 (2010)]. Limits of the method and potential applications for molecular spectroscopy are discussed.

  8. TOPICAL REVIEW: Progress in laser spectroscopy at radioactive ion beam facilities

    NASA Astrophysics Data System (ADS)

    Cheal, B.; Flanagan, K. T.

    2010-11-01

    In the last decade there has been a renaissance in laser spectroscopy at on-line facilities. This has included the introduction of ion traps and the use of laser ion sources to study the hyperfine structure of exotic nuclei far from stability and produce selective enhancement of isomeric beams. In-source spectroscopy has allowed the study of rare isotopes with yields as low as 0.1 atoms per second. In the case of high-resolution spectroscopy, cooling and trapping the ions has dramatically improved the sensitivity. Some elements that were previously inaccessible to laser spectroscopy are now available for study through the technique of in-trap optical pumping. This paper reviews the field of laser spectroscopy at on-line facilities, with an emphasis on new techniques. A summary of experimental data is presented.

  9. Laser ion source for isobaric heavy ion collider experiment

    NASA Astrophysics Data System (ADS)

    Kanesue, T.; Kumaki, M.; Ikeda, S.; Okamura, M.

    2016-02-01

    Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is 96Ru + 96Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

  10. Laser ion source for isobaric heavy ion collider experiment.

    PubMed

    Kanesue, T; Kumaki, M; Ikeda, S; Okamura, M

    2016-02-01

    Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is (96)Ru + (96)Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions. PMID:26931981

  11. ARTICLES: Influence Factors on Particle Growth for On-line Aerosol Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Xia, Wei-wei; Ti, Ru-fang; Zhang, Zi-Iiang; Zheng, Hai-yang; Fang, Li

    2010-06-01

    An evaporation/condensation flow cell was developed and interfaced with the matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometer for on-line bioaerosol detection and characterization, which allows matrix addition by condensation onto the laboratory-generated bioaerosol particles. The final coated particle exiting from the condenser is then introduced into the aerodynamic particle sizer spectrometer or home-built aerosol laser time-of-flight mass spectrometer, and its aerodynamic size directly effects on the matrix-to-analyte molar ratio, which is very important for MALDI technique. In order to observe the protonated analyte molecular ion, and then determine the classification of biological aerosols, the matrix-to-analyte molar ratio must be appropriate. Four experimental parameters, including the temperature of the heated reservoir, the initial particle size, its number concentration, and the matrix material, were tested experimentally to analyze their influences on the final particle size. This technique represents an on-line system of detection that has the potential to provide rapid and reliable identification of airborne biological aerosols.

  12. On-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry using a microflow nebulizer inserted in the laser ablation chamber

    NASA Astrophysics Data System (ADS)

    Pickhardt, Carola; Izmer, Andrej V.; Zoriy, Miroslav V.; Schaumlöffel, D.; Sabine Becker, J.

    2006-02-01

    Laser ablation ICP-MS (inductively coupled plasma mass spectrometry) is becoming one of the most important analytical techniques for fast determination of trace impurities in solid samples. Quantification of analytical results requires matrix-matched standards, which are in some cases (e.g., high-purity metals, proteins separated by 2D gel electrophoresis) difficult to obtain or prepare. In order to overcome the quantification problem a special arrangement for on-line solution-based calibration has been proposed in laser ablation ICP-MS by the insertion of a microflow nebulizer in the laser ablation chamber. This arrangement allows an easy, accurate and precise quantification by on-line isotope dilution using a defined standard solution with an isotope enriched tracer nebulized to the laser-ablated sample material. An ideal matrix matching in LA-ICP-MS is therefore obtained during the measurement. The figures of merit of this arrangement with a microflow nebulizer inserted in the laser ablation chamber and applications of on-line isotope dilution in LA-ICP-MS on two different types of sample material (NIST glass SRM 612 and NIST apple leaves SRM 1515) will be described.

  13. Laser Optical Disk: The Coming Revolution in On-Line Storage.

    ERIC Educational Resources Information Center

    Fujitani, Larry

    1984-01-01

    Review of similarities and differences between magnetic-based and optical disk drives includes a discussion of the electronics necessary for their operation; describes benefits, possible applications, and future trends in development of laser-based drives; and lists manufacturers of laser optical disk drives. (MBR)

  14. Laser ion source for multi-nucleon transfer reaction products

    NASA Astrophysics Data System (ADS)

    Hirayama, Y.; Watanabe, Y. X.; Imai, N.; Ishiyama, H.; Jeong, S. C.; Miyatake, H.; Oyaizu, M.; Kimura, S.; Mukai, M.; Kim, Y. H.; Sonoda, T.; Wada, M.; Huyse, M.; Kudryavtsev, Yu.; Van Duppen, P.

    2015-06-01

    We have developed a laser ion source for the target-like fragments (TLFs) produced in multi-nucleon transfer (MNT) reactions. The operation principle of the source is based on the in-gas laser ionization and spectroscopy (IGLIS) approach. In the source TLFs are thermalized and neutralized in high pressure and high purity argon gas, and are extracted after being selectively re-ionized in a multi-step laser resonance ionization process. The laser ion source has been implemented at the KEK Isotope Separation System (KISS) for β-decay spectroscopy of neutron-rich isotopes with N = 126 of nuclear astrophysical interest. The simulations of gas flow and ion-beam optics have been performed to optimize the gas cell for efficient thermalization and fast transporting the TLFs, and the mass-separator for efficient transport with high mass-resolving power, respectively. To confirm the performances expected at the design stage, off-line experiments have been performed by using 56Fe atoms evaporated from a filament in the gas cell. The gas-transport time of 230 ms in the argon cell and the measured KISS mass-resolving power of 900 are consistent with the designed values. The high purity of the gas-cell system, which is extremely important for efficient and highly-selective production of laser ions, was achieved and confirmed from the mass distribution of the extracted ions. After the off-line tests, on-line experiments were conducted by directly injecting energetic 56Fe beam into the gas cell. After thermalization of the injected 56Fe beam, laser-produced singly-charged 56Fe+ ions were extracted. The extraction efficiency and selectivity of the gas cell in the presence of plasma induced by 56Fe beam injection as well as the time profile of the extracted ions were investigated; extraction efficiency of 0.25%, a beam purity of >99% and an extraction time of 270 ms. It has been confirmed that the performance of the KISS laser ion source is satisfactory to start the measurements of

  15. On-line gas-free electrodialytic eluent generator for capillary ion chromatography.

    PubMed

    Yang, Bingcheng; Takeuchi, Masaki; Dasgupta, Purnendu K

    2008-01-01

    Both low- and high-pressure, gas-free, capillary-scale electrodialytic generators for eluents in ion chromatography are described. While the low-pressure devices rely on planar or tubular membranes, the high-pressure devices rely on ion-exchange beads used both as one-way ionic gates and as ball-on-seat valves to provide sealing. The high-pressure device is easily implemented in the form of a commercial cross fitting and can withstand at least 1400 psi. By design these devices do not produce gas in the eluent channel; hence, it is not necessary to remove gas afterward. With appropriate electrolytes and electrode polarities, such devices can produce either acid or base or salt. In regard to ionic transport, the behavior of these devices fully corresponds to that of a semiconductor diode. To our knowledge, this is the first time such complete equivalence of ion transport through ion-exchange media and with the more familiar example of electron transport through a semiconductor diode under both forward- and reverse-biased conditions have been demonstrated. Reverse bias can be applied to minimize/prevent Donnan-forbidden leakage or ion exchange. Even with 4 M KOH in the electrode compartments and 4 microL/min water flowing through the eluent channel, with a reverse bias of -12 V, the leakage KOH concentration is <30 microM, whereas the KOH concentration with zero voltage applied, herein after termed open circuit penetration (OCP), is 1600 microM. It is suggested that this OCP occurs not as much through Donnan-forbidden leakage but via ion exchange. Chromatograms and reproducibility data are presented for both isocratic and gradient chromatography, using ion-exchange, latex-modified, open tubular and packed monolithic columns. PMID:18062705

  16. An effective method for on-line corrections of two-axes laser mount.

    NASA Astrophysics Data System (ADS)

    Lála, P.; Pivo, K.

    An algorithm for correction of two-axes laser mount direction and gates in case of atmospheric drag induced deviations from the predicted satellite motion is described. Results of numerical simulations are shown.

  17. Laser ion sources for particle accelerators

    NASA Astrophysics Data System (ADS)

    Sherwood, T. R.

    1996-05-01

    There is an interest in accelerating atomic nuclei to produce particle beams for medical therapy, atomic and nuclear physics, inertial confinement fusion and particle physics. Laser Ion Sources, in which ions are extracted from plasma created when a high power density laser beam pulse strikes a solid surface in a vacuum, are not in common use. However, some new developments in which heavy ions have been accelerated show that such sources have the potential to provide the beams required for high-energy accelerator systems.

  18. “Development of an Automated On-line Electrochemical Chlorite Ion Sensor”

    PubMed Central

    Myers, John N.; Steinecker, William H.; Sandlin, Zechariah D.; Cox, James A.; Gordon, Gilbert; Pacey, Gilbert E.

    2012-01-01

    A sensor system for the automatic, in-line, determination of chlorite ion is reported. Electroanalytical measurements were performed in electrolyte-free liquids by using an electrochemical probe (EC), which enables in-line detection in high-resistance media such as disinfected water. Cyclic voltammetry scan rate studies suggest that the current arising from the oxidation of chlorite ion at an EC probe is mass-transfer limited. By coupling FIA with an EC probe amperometric cell, automated analysis was achieved. This sensor is intended to fulfill the daily monitoring requirements of the EPA DBP regulations for chlorite ion. Detection limits of 0.02-0.13 mg/L were attained, which is about one order of magnitude below the MRDL. The sensor showed no faradaic signal for perchlorate, chlorate, or nitrate. The lifetime and stability of the sensor were investigated by measuring calibration curves over time under constant-flow conditions. Detection limits of <0.1 mg/L were repeatedly achieved over a period of three weeks. PMID:22608440

  19. An All-Solid-State High Repetiton Rate Titanium:Sapphire Laser System For Resonance Ionization Laser Ion Sources

    NASA Astrophysics Data System (ADS)

    Mattolat, C.; Rothe, S.; Schwellnus, F.; Gottwald, T.; Raeder, S.; Wendt, K.

    2009-03-01

    On-line production facilities for radioactive isotopes nowadays heavily rely on resonance ionization laser ion sources due to their demonstrated unsurpassed efficiency and elemental selectivity. Powerful high repetition rate tunable pulsed dye or Ti:sapphire lasers can be used for this purpose. To counteract limitations of short pulse pump lasers, as needed for dye laser pumping, i.e. copper vapor lasers, which include high maintenance and nevertheless often only imperfect reliability, an all-solid-state Nd:YAG pumped Ti:sapphire laser system has been constructed. This could complement or even replace dye laser systems, eliminating their disadvantages but on the other hand introduce shortcomings on the side of the available wavelength range. Pros and cons of these developments will be discussed.

  20. Carbon Multicharged Ion Generation from Laser Plasma

    NASA Astrophysics Data System (ADS)

    Balki, Oguzhan; Elsayed-Ali, Hani E.

    2014-10-01

    Multicharged ions (MCI) have potential uses in different areas such as microelectronics and medical physics. Carbon MCI therapy for cancer treatment is considered due to its localized energy delivery to hard-to-reach tumors at a minimal damage to surrounding tissues. We use a Q-switched Nd:YAG laser with 40 ns pulse width operated at 1064 nm to ablate a graphite target in ultrahigh vacuum. A time-of-flight energy analyzer followed by a Faraday cup is used to characterize the carbon MCI extracted from the laser plasma. The MCI charge state and energy distribution are obtained. With increase in the laser fluence, the ion charge states and ion energy are increased. Carbon MCI up to C+9 are observed along with carbon clusters. When an acceleration voltage is applied between the carbon target and a grounded mesh, ion extraction is observed to increase with the applied voltage. National Science Foundation.

  1. Laser-induced fluorescence method for on-line molecular isotopologues of iodine-127, iodine-129, iodine-131 detected in gaseous media using a tunable diode laser

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Shnyrev, S. L.; Sobolevsky, I. V.

    2016-06-01

    The letter reports on the development of a laser-induced fluorescence method for on-line selective measurement of 127I2, 129I2, 131I2, 129I127I, 127I131I, 129I131I isotopologue concentrations in gaseous media. The method is based on the excitation of molecular iodine isotopologues’ fluorescence by tunable diode laser (632–637 nm) radiation at three or four wavelengths corresponding to the 127I2, 131I2, 129I127I, 129I131I absorption line centers. Boundary relations for concentrations of simultaneously measured iodine isotopologues is about 10‑5–10‑6.

  2. On-line computer system to minimize laser injuries during surgery: preliminary system layout and proposal of the key features.

    PubMed

    Canestri, F

    1999-01-01

    The aim of this paper is to investigate some new user interface ideas and related application packages which aim to improve the degree of safety in an operating room during surgical operations in which an invasive laser beam is deployed. The overall value of the proposition is that a means is provided which ensures the successful completion of the surgical case while minimizing the risk of thermal and mechanical injuries to healthy tissues adjacent to the surgical field. According to surgeons operating with a variety of CO2 lasers available at both the National Cancer Institute in Milan, Italy, and the Sackler School of Medicine, Tel Aviv University, Israel, each laser device presents different cutting and coagulation properties. In order to identify which 'ideal' procedure might corroborate the subjective impression of each surgeon and also to provide one common tool to ensure procedures with a high level of safety, the author has worked for several months with surgeons and technicians of both Institutions to define the general design of a new on-line surgical operation planning and design system to be used during the pre-operative briefing activities and also as a consultation tool during operation. This software package will be developed and tested on both 'C' and FORTRAN compilers running on a commercially available PC which is driving a continuous wave (CW) CO2 laser device via its Instrument Bus interface. The present proposal describes the details of a software package called LCA (Laser-beam Controller and Adviser) which performs several controls in parallel on the key output parameters of a laser beam device during its utilization in delicate surgical operations. The required performances of this device needed during a given surgical operation are pre-simulated and compared against the well-known safety limits, which are stored in the computer's mass storage. If the surgeon's decision about the laser device set-up are considered to be too close to the

  3. Ion beams from laser-generated plasmas

    NASA Technical Reports Server (NTRS)

    Hughes, R. H.; Anderson, R. J.; Gray, L. G.; Rosenfeld, J. P.; Manka, C. K.; Carruth, M. R.

    1980-01-01

    The paper describes the space-charge-limited beams produced by the plasma blowoffs generated by 20-MW bursts of 1.06-micron radiation from an active Q-switched Nd:YAG laser. Laser power densities near 10 to the 11th/sq cm on solid targets generate thermalized plasma plumes which drift to a 15-kV gridded extraction gap where the ions are extracted, accelerated, and electrostatically focused; the spatially defined ion beams are then magnetically analyzed to determine the charge state content in the beams formed from carbon, aluminum, copper, and lead targets. This technique preserves time-of-flight (TOF) information in the plasma drift region, which permits plasma ion temperatures and mass flow velocities to be determined from the Maxwellian ion curve TOF shapes for the individual charge species.

  4. Ion beam control in laser plasma interaction

    NASA Astrophysics Data System (ADS)

    Kawata, S.; Izumiyama, T.; Sato, D.; Nagashima, T.; Takano, M.; Barada, D.; Gu, Y. J.; Ma, Y. Y.; Kong, Q.; Wang, P. X.; Wang, W. M.

    2016-03-01

    By a two-stage successive acceleration in laser ion acceleration, our 2.5-dimensional particle-in-cell simulations demonstrate a remarkable increase in ion energy by a few hundreds of MeV; the maximum proton energy reaches about 250MeV. The ions are accelerated by the inductive continuous post-acceleration in a laser plasma interaction together with the target normal sheath acceleration and the breakout afterburner mechanism. An intense short-pulse laser generates a strong current by high-energy electrons accelerated, when an intense short- pulse laser illuminates a plasma target. The strong electric current creates a strong magnetic field along the high-energy electron current in the plasma. During the increase phase in the magnetic field strength, the moving longitudinal inductive electric field is induced by the Faraday law, and accelerates the forward-moving ions continously. The multi-stage acceleration provides a unique controllability in the ion energy and its quality.

  5. Proton emission from a laser ion source

    SciTech Connect

    Torrisi, L.; Cavallaro, S.; Gammino, S.; Cutroneo, M.; Margarone, D.

    2012-02-15

    At intensities of the order of 10{sup 10} W/cm{sup 2}, ns pulsed lasers can be employed to ablate solid bulk targets in order to produce high emission of ions at different charge state and kinetic energy. A special interest is devoted to the production of protons with controllable energy and current from a roto-translating target irradiated in repetition rate at 1-10 Hz by a Nd:Yag pulsed laser beam. Different hydrogenated targets based on polymers and hydrates were irradiated in high vacuum. Special nanostrucutres can be embedded in the polymers in order to modify the laser absorption properties and the amount of protons to be accelerated in the plasma. For example, carbon nanotubes may increase the laser absorption and the hydrogen absorption to generate high proton yields from the plasma. Metallic nanostrucutres may increase the electron density of the plasma and the kinetic energy of the accelerated protons. Ion collectors, ion energy analyzer, and mass spectrometers, used in time-of-flight configuration, were employed to characterize the ion beam properties. A comparison with traditional proton ion source is presented and discussed.

  6. Direct analysis of highly oxidised organic aerosol constituents by on-line ion trap mass spectrometry in the negative-ion mode.

    PubMed

    Warscheid, Bettina; Hoffmann, Thorsten

    2002-01-01

    On-line ion trap mass spectrometry (ITMS) enables the characterisation of constituents of biogenic secondary organic aerosols in complex organic reaction mixtures. This real-time analysis is achieved by directly introducing the airborne particles into the ion source of the mass spectrometer. Negative-ion chemical ionisation at atmospheric pressure (APCI(-)) was used as the ionisation method of choice. The aerosols were generated from the gas-phase ozonolysis of two C10H16-terpenes (alpha-pinene and limonene), and investigated by performing on-line APCI(-)-ITMS(n). Highly oxidised compounds were tentatively identified as important particle-phase products. Based on recent investigations of low-energy collision-induced dissociation pathways of a wide range of deprotonated multifunctional carboxylic acid species derived from monoterpene precursors (Warscheid B, Hoffmann T. Rapid Commun. Mass Spectrom. 2001; 15: 2259), the formation of structurally different C10H16O5 and C10H16O6 species, such as acidic esters from alpha-pinene and aldo-hydroxycarboxylic acids from limonene, is proposed. PMID:11870886

  7. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    PubMed

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-01

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. PMID:25440666

  8. Ion laser isotope enrichment by photo-predissociation of formaldehyde

    DOEpatents

    Marling, John B.

    1977-06-17

    Enrichment of carbon, hydrogen and/or oxygen isotopes by means of isotopically selective photo-predissociation of formaldehyde is achieved by irradiation with a fixed frequency ion laser, specifically, a neon, cadmium, or xenon ion laser.

  9. Laser Ion Source Operation at the TRIUMF Radioactive Ion Beam Facility

    NASA Astrophysics Data System (ADS)

    Lassen, J.; Bricault, P.; Dombsky, M.; Lavoie, J. P.; Gillner, M.; Gottwald, T.; Hellbusch, F.; Teigelhöfer, A.; Voss, A.; Wendt, K. D. A.

    2009-03-01

    The TRIUMF Resonant Ionization Laser Ion Source (RILIS) for radioactive ion beam production is presented, with target ion source, laser beam transport, laser system and operation. In this context aspects of titanium sapphire (TiSa) laser based RILIS and facility requirements are discussed and results from the first years of TRILIS RIB delivery are given.

  10. On-Line Desalting of Crude Oil in the Source Region of a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

    NASA Astrophysics Data System (ADS)

    Chanthamontri, C. Ken; Stopford, Andrew P.; Snowdon, Ryan W.; Oldenburg, Thomas B. P.; Larter, Stephen R.

    2014-08-01

    The presence of dissolved metal ions in waters associated with crude oils has many negative implications for the transport, processing, and refining of petroleum. In addition, mass spectrometric analysis of sodium containing crude oil samples suffers from ionization suppression, unwanted adduct formation, and an increase in the complexity of data analysis. Here, we describe a method for the reduction/elimination of these adverse effects by modification of the source region gas-inlet system of a 12 T Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Several acids were examined as part of this study, with the most suitable for on-line desalting found to have both high vapor pressure and low pKa; 12.1 M HCl showed the strongest desalting effect for crude oil samples with a sodium removal index (SRI) of 88%-100% ± 7% for the NaOS compound class. In comparison, a SRI of only 38% ± 9% was observed for a H2O/toluene solution-phase extraction of Oil 1. These results clearly demonstrate the increased efficacy of pseudo-vapor phase desalting with the additional advantages that initial sample solution conditions are preserved and no sample preparation is required prior to analysis.

  11. Laser-induced breakdown spectroscopy for on-line engine equivalence ratio measurements.

    PubMed

    Ferioli, Francesco; Puzinauskas, Paulius V; Buckley, Steven G

    2003-09-01

    Laser-induced breakdown spectroscopy (LIBS) has been used to measure the equivalence ratio of a spark-ignited engine in a laboratory setting. Spectral features of C (711.3 nm), O (776.6 nm), N (746.3 and 743.8 nm), and CN (broad emission 707-734 nm) were used to quantify the equivalence ratio over a range from phi = 0.8 to phi = 1.2. The C/N and C/O peak ratios were found to be successful measurement metrics, compared with a standard exhaust gas oxygen analyzer, for averaged measurements. Some variation in the measurements was observed as a function of engine load. Single-shot data based on a CN/air peak ratio were evaluated using a separate calibration from averaged measurements, and the average of the single-shot data was found to agree well with the exhaust gas oxygen analyzer. The scatter in the single-shot data was substantially higher at lower equivalence ratios. The measurements including the CN peak were slightly sensitive to load, possibly due to pressure changes in the sample as the load increases, or possibly due to changes in the particle size distribution in the gas stream. PMID:14611051

  12. Master on Photonics and Laser Technologies: on-line teaching experience

    NASA Astrophysics Data System (ADS)

    Paredes, Ángel; Michinel, Humberto; Salgueiro, José R.; Vázquez-Dorrío, Benito; Yáñez, Armando; Arines, Justo; Flores-Arias, M. Teresa

    2014-07-01

    The Galician Universitary System (SUG) in the framework of the European studies under the Bologna process presents a huge number of Masters courses. In this work we present the teaching framework of the Science Masters on "Photonics and Laser Technologies", coordinated by the University of Vigo (UVigo) and involving the three Universities of Galicia: University of Vigo (UVigo), University of Santiago de Compostela (USC) and University of Coruña (UdC). The aim of this work is to show how teaching at this Masters is carried out using an online platform so that the whole expertise of all the three Universities can be properly exploited and the geographic dispersion of lecturers and students overcame. The used platform permits the students to attend the lessons from their own Universities without wasting time and money on traveling. Besides, each lecturer can teach from his/her own University, allowing the combination of this activity with other professional and scientific duties. Thanks to this tool, the Masters could host students that followed the lessons from other different countries. The platform has been used for lectures, seminar classes, examinations, conferences and coordination activities between teachers and students.

  13. On-line wall-free cell for laser-induced fluorescence detection in capillary electrophoresis.

    PubMed

    Yu, Chang-Zhu; He, You-Zhao; Xie, Hai-Yang; Gao, Yong; Gan, Wu-Er; Li, Jun

    2009-05-15

    A wall-free detection method based on liquid junction in a capillary gap was proposed for laser-induced fluorescence (LIF) of capillary electrophoresis (CE). The capillary gap of the wall-free cell was fabricated by etching a 10-mm x 50-microm I.D. fused-silica capillary to obtain a polyimide coating sleeve, decoating about 6mm at one end of both 50 microm I.D. separation and liquid junction capillary, inserting the treated capillary ends into the coating sleeve oppositely, fixing the capillaries with a gap distance of 140 microm by epoxy glue and removing the coating sleeve by burning. The theoretical model, experimental results and wall-free cell images indicated that the gap distance and applied voltage were main influence factors on the wall-free detection. Since the wall-free cell increased the absorption light path and avoided the stray light from the capillary wall, it improved the ratio of signal to noise and limit of detection (LOD) of CE-LIF. Three flavin compounds of riboflavin (RF), flavin mononucleotide sodium (FMN) and flavin adenine dinucleotide disodium (FAD) were used to evaluate the wall-free detection method. Compared with on-column cell, the LODs of the wall-free cell were improved 15-, 6- and 9-fold for RF, FMN and FAD, respectively. The linear calibration concentrations of the flavins ranged from 0.005 to 5.0 micromol/L. The column efficiency was in the range from 1.0 x 10(5) to 2.5 x 10(5) plates. The wall-free detection of CE-LIF was applied to the analysis of the flavins in spinach and lettuce leaves. PMID:19329123

  14. Laser photoelectron spectroscopy of ions

    SciTech Connect

    Ellison, G.B.

    1993-12-01

    During the last year the author has (a) completed a review article that critically contrasts three methods to measure R-H bond energies, (b) finished a spectroscopic study of the phenylnitrene anion, and (c) successfully completed an overhaul of the light source of the photodetachment spectrometer. The new light source is based on an Ar III laser that provides approximately 100 W of 3.531 eV photons.

  15. Oncological hadrontherapy with laser ion accelerators

    NASA Astrophysics Data System (ADS)

    Bulanov, S. V.; Esirkepov, T. Zh.; Khoroshkov, V. S.; Kuznetsov, A. V.; Pegoraro, F.

    2002-11-01

    === Effective ion acceleration during the interaction of an ultra short and ultra intense laser pulse with matter is one of the most important applications of the presently available compact laser systems with multi-terawatt and petawatt power. The use of an intense collimated beam of protons produced by a high-intensity laser pulse interacting with a plasma for the proton treatment of oncological diseases [1,2] is discussed. The fast proton beam is produced at the target by direct laser acceleration. An appropriately designed double-layer target scheme is proposed in order to achieve high-quality proton beams. The generation of high quality proton beams is proved with Particle in Cell simulations. === [1] S. V. Bulanov, V. S. Khoroshkov, Plasma Phys. Rep. 28, 453 (2002). [2] S. V. Bulanov, T. Zh. Esirkepov, V. S. Khoroshkov, A.V. Kuznetsov, F. Pegoraro, Phys. Lett. A 299, 240 (2002)

  16. Controllability in Multi-Stage Laser Ion Acceleration

    NASA Astrophysics Data System (ADS)

    Kawata, S.; Kamiyama, D.; Ohtake, Y.; Barada, D.; Ma, Y. Y.; Kong, Q.; Wang, P. X.; Gu, Y. J.; Li, X. F.; Yu, Q.

    2015-11-01

    The present paper shows a concept for a future laser ion accelerator, which should have an ion source, ion collimators, ion beam bunchers and ion post acceleration devices. Based on the laser ion accelerator components, the ion particle energy and the ion energy spectrum are controlled, and a future compact laser ion accelerator would be designed for ion cancer therapy or for ion material treatment. In this study each component is designed to control the ion beam quality. The energy efficiency from the laser to ions is improved by using a solid target with a fine sub-wavelength structure or a near-critical density gas plasma. The ion beam collimation is performed by holes behind the solid target or a multi-layered solid target. The control of the ion energy spectrum and the ion particle energy, and the ion beam bunching are successfully realized by a multi-stage laser-target interaction. A combination of each component provides a high controllability of the ion beam quality to meet variable requirements in various purposes in the laser ion accelerator. The work was partly supported by MEXT, JSPS, ASHULA project/ ILE, Osaka University, CORE (Center for Optical Research and Education, Utsunomiya University, Japan), Fudan University and CDI (Creative Dept. for Innovation) in CCRD, Utsunomiya University.

  17. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    NASA Astrophysics Data System (ADS)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  18. Influence of Reverse Expansion of Laser Plasma on Ions Acceleration

    NASA Astrophysics Data System (ADS)

    Sysoev, Alexander A.; Gracheva, O. I.; Karpov, A. V.

    Effect of laser plasma reverse extension is described in this paper. Influence of the effect on ion acceleration in a laser ion source is researched. This effect leads to sedimentation of ions on metal target, which significantly impacts acceleration time of other ions. In this case, the ions also tend to travel major part of their path with constant velocity. This allows one to consider movement of the ions in plasma drift space, when optimizing time focusing ability of the TOF analyzer.

  19. A laser ablation source for offline ion production at LEBIT

    NASA Astrophysics Data System (ADS)

    Izzo, C.; Bollen, G.; Bustabad, S.; Eibach, M.; Gulyuz, K.; Morrissey, D. J.; Redshaw, M.; Ringle, R.; Sandler, R.; Schwarz, S.; Valverde, A. A.

    2016-06-01

    A laser ablation ion source has been developed and implemented at the Low-Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory. This offline ion source enhances the capabilities of LEBIT by providing increased access to ions used for calibration measurements and checks of systematic effects as well as stable and long-lived ions of scientific interest. The design of the laser ablation ion source and a demonstration of its successful operation are presented.

  20. On-line ion chemistry for the AMS analysis of 90Sr and 135,137Cs

    NASA Astrophysics Data System (ADS)

    Eliades, J.; Zhao, X.-L.; Litherland, A. E.; Kieser, W. E.

    2013-01-01

    The analysis of 90Sr by AMS has so far required the use of very large tandem accelerators in order to separate the isobar 90Zr by the rate-of-energy-loss method. The analysis of 135,137Cs by AMS has never been attempted as the separation of the isobars 135,137Ba by the traditional method requires even higher energies, so that this approach would become prohibitively expensive for routine analysis. Following the successful demonstration of Cl--S- separation by the Isobar Separator, the same apparatus was used to test the separation of other pairs of isobars. Surprisingly effective results were obtained with NO2 gas in the cases of SrF3--ZrF3- and CsF2--BaF2- separations. Reduction factors of ∼4 × 10-6 for ZrF3-/SrF3- and ∼2 × 10-5 for BaF2-/CsF2- were measured. SrF3- and CsF2- are both super-halogen anions and are preferentially produced in the ion source rather than ZrF3- and BaF2- when using the PbF2 matrix-assisted method. Reduction factors for ion source production with such targets of ∼3 × 10-5 for ZrF3--SrF3- and ∼5 × 10-4 for BaF2--CsF2- were found. The combined methods would suggest a theoretical detection sensitivity for 90Sr/Sr ∼6 × 10-16, 135Cs/Cs ∼7 × 10-15 and 137Cs/Cs ∼1 × 10-14, assuming 10 ppm Zr and Ba contamination in the AMS targets. In addition to the earlier Cl--S- separation work, these measurements further illustrate the potential of on-line ion chemical methods for broadening the analytical scope of small AMS systems.

  1. Applying the diode laser spectroscopy method for high sensitivity on-line control of 13С contained in the gaseous mixture with 12С

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Kondrashov, A. A.; Shnyrev, S. L.

    2016-06-01

    This letter details the development of an on-line control method for carbon dioxide molecules of various isotopes contained in gaseous media on the basis of a tunable diode laser operating in the 4860–4880 cm‑1 range. It shows that the sensitivity of 13С registering may amount to ~1012 cm‑3.

  2. Development of laser noninvasive on-line diagnostics of oncological diseases based on the absorption method in the 4860–4880 cm‑1 spectral range

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Shnyrev, S. L.; Kondrashov, A. A.

    2016-07-01

    A novel method for noninvasive on-line diagnostics of gastrointestinal oncological diseases using a diode laser in the 4860–4880 cm‑1 frequency range is proposed. The method is based on measuring the concentration of 13С during expiration. The accuracy of the method allows performing early diagnostics of diseases.

  3. Laser-cooled continuous ion beams

    SciTech Connect

    Schiffer, J.P.; Hangst, J.S.; Nielsen, J.S.

    1995-08-01

    A collaboration with a group in Arhus, Denmark, using their storage ring ASTRID, brought about better understanding of ion beams cooled to very low temperatures. The longitudinal Schottky fluctuation noise signals from a cooled beam were studied. The fluctuation signals are distorted by the effects of space charge as was observed in earlier measurements at other facilities. However, the signal also exhibits previously unobserved coherent components. The ions` velocity distribution, measured by a laser fluorescence technique suggests that the coherence is due to suppression of Landau damping. The observed behavior has important implications for the eventual attainment of a crystalline ion beam in a storage ring. A significant issue is the transverse temperature of the beam -- where no direct diagnostics are available and where molecular dynamics simulations raise interesting questions about equilibrium.

  4. In-Source Laser Spectroscopy with the Laser Ion Source and Trap: First Direct Study of the Ground-State Properties of Po,219217

    NASA Astrophysics Data System (ADS)

    Fink, D. A.; Cocolios, T. E.; Andreyev, A. N.; Antalic, S.; Barzakh, A. E.; Bastin, B.; Fedorov, D. V.; Fedosseev, V. N.; Flanagan, K. T.; Ghys, L.; Gottberg, A.; Huyse, M.; Imai, N.; Kron, T.; Lecesne, N.; Lynch, K. M.; Marsh, B. A.; Pauwels, D.; Rapisarda, E.; Richter, S. D.; Rossel, R. E.; Rothe, S.; Seliverstov, M. D.; Sjödin, A. M.; Van Beveren, C.; Van Duppen, P.; Wendt, K. D. A.

    2015-01-01

    A Laser Ion Source and Trap (LIST) for a thick-target, isotope-separation on-line facility has been implemented at CERN ISOLDE for the production of pure, laser-ionized, radioactive ion beams. It offers two modes of operation, either as an ion guide, which performs similarly to the standard ISOLDE resonance ionization laser ion source (RILIS), or as a more selective ion source, where surface-ionized ions from the hot ion-source cavity are repelled by an electrode, while laser ionization is done within a radio-frequency quadrupole ion guide. The first physics application of the LIST enables the suppression of francium contamination in ion beams of neutron-rich polonium isotopes at ISOLDE by more than 1000 with a reduction in laser-ionization efficiency of only 20. Resonance ionization spectroscopy is performed directly inside the LIST device, allowing the study of the hyperfine structure and isotope shift of 217Po for the first time. Nuclear decay spectroscopy of 219Po is performed for the first time, revealing its half-life, α -to-β -decay branching ratio, and α -particle energy. This experiment demonstrates the applicability of the LIST at radioactive ion-beam facilities for the production and study of pure beams of exotic isotopes.

  5. Calcium and lithium ion production for laser ion source

    NASA Astrophysics Data System (ADS)

    Okamura, M.; Palm, K.; Stifler, C.; Steski, D.; Ikeda, S.; Kumaki, M.; Kanesue, T.

    2016-02-01

    Calcium and lithium ion beams are required by NASA Space Radiation Laboratory at Brookhaven National Laboratory to simulate the effects of cosmic radiation. To identify the difficulties in providing such highly reactive materials as laser targets, both species were experimentally tested. Plate shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6 ns 1064 nm neodymium-doped yttrium aluminum garnet laser. We found significant oxygen contamination in both the Ca and Li high charge state beams due to the rapid oxidation of the surfaces. A large spot size, low power density laser was used to create low charge state beams without scanning the targets. The low charge state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely of oxide with a low power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low power shot. To measure the rate of oxidation, we shot the low power laser at the target repeatedly at 10 s, 30 s, 60 s, and 120 s interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

  6. Calcium and lithium ion production for laser ion source.

    PubMed

    Okamura, M; Palm, K; Stifler, C; Steski, D; Ikeda, S; Kumaki, M; Kanesue, T

    2016-02-01

    Calcium and lithium ion beams are required by NASA Space Radiation Laboratory at Brookhaven National Laboratory to simulate the effects of cosmic radiation. To identify the difficulties in providing such highly reactive materials as laser targets, both species were experimentally tested. Plate shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6 ns 1064 nm neodymium-doped yttrium aluminum garnet laser. We found significant oxygen contamination in both the Ca and Li high charge state beams due to the rapid oxidation of the surfaces. A large spot size, low power density laser was used to create low charge state beams without scanning the targets. The low charge state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely of oxide with a low power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low power shot. To measure the rate of oxidation, we shot the low power laser at the target repeatedly at 10 s, 30 s, 60 s, and 120 s interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam. PMID:26931962

  7. Calcium and lithium ion production for laser ion source

    SciTech Connect

    Okamura, M.; Palm, K.; Stifler, C.; Steski, D.; Ikeda, S.; Kumaki, M.; Kanesue, T.

    2015-08-23

    Calcium and lithium ion beams are required by NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) to simulate the effects of cosmic radiation. To find out difficulties to provide such high reactive material as laser targets, the both species were experimentally tested. Plate-shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6ns, 1064nm Nd:YAG laser. We found significant oxygen contamination in both the Ca and Li high-charge-state beams due to the rapid oxidation of the surfaces. A large-spot-size, low-power-density laser was then used to analyze the low-charge-state beams without scanning the targets. The low-charge-state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely with a low-power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low-power shot. To measure the rate of oxidation, we shot the low-power laser at the target repeatedly at 10sec, 30sec, 60sec, and 120sec interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

  8. Theory of the ion-channel laser

    SciTech Connect

    Whittum, D.H.

    1990-09-01

    A relativistic electron beam propagating through a plasma in the ion-focussed regime exhibits an electromagnetic instability with peak growth rate near a resonant frequency {omega}{approximately}2 {gamma}{sup 2} {omega}{beta}, where {gamma} is the Lorentz factor and {omega}{beta} is the betatron frequency. The physical basis for this instability is that an ensemble of relativistic simple harmonic oscillators, weakly driven by an electromagnetic wave, will lose energy to the wave through axial bunching. This bunching'' corresponds to the development of an rf component in the beam current, and a coherent centroid oscillation. The subject of this thesis is the theory of a laser capitalizing on this electromagnetic instability. A historical perspective is offered. The basic features of relativistic electron beam propagation in the ion-focussed regime are reviewed. The ion-channel laser (ICL) instability is explored theoretically through an eikonal formalism, analgous to the KMR'' formalism for the free-electron laser (FEL). The dispersion relation is derived, and the dependence of growth rate on three key parameters is explored. Finite temperature effects are assessed. From this work it is found that the typical gain length for amplification is longer than the Rayleigh length and we go on to consider three mechanisms which will tend to guide waveguide. First, we consider the effect of the ion channel as a dielectric waveguide. We consider next the use of a conducting waveguide, appropriate for a microwave amplifier. Finally, we examine a form of optical guiding'' analgous to that found in the FEL. The eikonal formalism is used to model numerically the instability through and beyond saturation. Results are compared with the numerical simulation of the full equations of motion, and with the analytic scalings. The analytical requirement on detuning spread is confirmed.

  9. Target life time of laser ion source for low charge state ion production

    SciTech Connect

    Kanesue,T.; Tamura, J.; Okamura, M.

    2008-06-23

    Laser ion source (LIS) produces ions by irradiating pulsed high power laser shots onto the solid state target. For the low charge state ion production, laser spot diameter on the target can be over several millimeters using a high power laser such as Nd:YAG laser. In this case, a damage to the target surface is small while there is a visible crater in case of the best focused laser shot for high charge state ion production (laser spot diameter can be several tens of micrometers). So the need of target displacement after each laser shot to use fresh surface to stabilize plasma is not required for low charge state ion production. We tested target lifetime using Nd:YAG laser with 5 Hz repetition rate. Also target temperature and vacuum condition were recorded during experiment. The feasibility of a long time operation was verified.

  10. Origin of 'energetic' ions from laser-produced plasmas.

    NASA Technical Reports Server (NTRS)

    Ehler, W.; Linlor, W. I.

    1973-01-01

    A fast-ion current peak, measured with an ion collector placed in the path of an expanding laser-produced plasma, was identified as carbon, nitrogen, and oxygen contaminants which originated from a tungsten target surface.

  11. Improved Analytical Performance of Negative 63Ni Ion Mobility Spectrometry for On-line Measurement of Propofol Using Dichloromethane as Dopant

    NASA Astrophysics Data System (ADS)

    Zhou, Qinghua; Hua, Lei; Wang, Changsong; Li, Enyou; Li, Haiyang

    2015-01-01

    On-line monitoring of propofol in exhaled air is a potential way to evaluate the anaesthesia depth for patients during surgery. In this study, a negative 63Ni ionization high resolution ion mobility spectrometer with Bradbury-Nielsen-Gate-Grid structure was built to measure propofol with reactant ions Cl-(H2O) n using dichloromethane as dopant. Instead of forming three propofol ions (M - H)-, M · O2 -, and (M2 - H)- with reactant ions O2 -(H2O) n , only product ion M · Cl- was produced when introducing dichloromethane gas. The peak-to-peak resolution ( R p-p) between reactant ions Cl-(H2O) n and product ion M · Cl- was 17.4, which was 1.6 times larger than that between O2 -(H2O) n and product ion. Furthermore, the linear response range using reactant ions Cl-(H2O) n was 3.5 times wider than that obtained with reactant ions O2 -(H2O) n .

  12. Single-trapped-ion vibronic Raman laser

    NASA Astrophysics Data System (ADS)

    di Fidio, C.; Vogel, W.; de Matos Filho, R. L.; Davidovich, L.

    2002-01-01

    We propose a model for a single-trapped-ion vibronic Raman laser and study its dynamics by using quantum-trajectory methods. In our treatment, it is essential that both the cavity field of the high-finesse optical cavity and the center-of-mass vibrational motion of the trapped ion be quantized. A transition from a super-Poissonian light source to a Poissonian lasing regime is obtained by increasing the Raman coupling constant. Furthermore, we demonstrate that a nonclassical regime can be realized, where the photon statistics becomes sub-Poissonian and the photons leak out of the cavity in an antibunched manner. This is achieved by exploiting nonlinear Stark shifts inherent in the model, which depend on both the number of cavity photons and the number of vibrational quanta.

  13. Laser ion beam production at CERN-ISOLDE: New features - More possibilities

    NASA Astrophysics Data System (ADS)

    Rothe, S.; Day Goodacre, T.; Fedorov, D. V.; Fedosseev, V. N.; Marsh, B. A.; Molkanov, P. L.; Rossel, R. E.; Seliverstov, M. D.; Veinhard, M.; Wendt, K. D. A.

    2016-06-01

    This article summarizes the current specifications and the latest features of the CERN-ISOLDE resonance ionization laser ion source (RILIS). This includes a description of the optical layout and the newly designed reference system. The ionization schemes for the laser ionized beams at ISOLDE are tabulated, including six new elements. All RILIS schemes are also made publicly available in the RILIS elements on-line database. Finally, we announce a paradigm shift in RILIS operation - the combination of a machine protection and a monitoring and control system has enabled on-call operation of the laser ion source for selected beams in 2014 and has become the standard mode of operation in 2015.

  14. In-gas-cell laser ion source for KEK isotope separation system

    NASA Astrophysics Data System (ADS)

    Mukai, M.; Hirayama, Y.; Jeong, S. C.; Imai, N.; Ishiyama, H.; Miyatake, H.; Oyaizu, M.; Watanabe, Y. X.; Kim, Y. H.

    2014-02-01

    The KEK isotope separation system (KISS) is an element-selective isotope separator under development at RIKEN. The in-gas-cell laser ion source is a critical component of the KISS, a gas cell filled with argon gas of 50 kPa enclosed in a vacuum chamber. In the gas cell, nuclear reaction products are stopped (i.e., thermalized and neutralized) and transported by a laminar flow of argon to the ionization region just upstream of the gas outlet, and thereby an element of interest among those reaction products is selectively ionized by two-color resonant laser irradiation. Recently, we succeeded to extract laser-ionized Fe ions by injecting an energetic Fe beam into the gas cell. Recent off- and on-line test results were presented and discussed.

  15. Post-acceleration of laser-induced ion beams

    NASA Astrophysics Data System (ADS)

    Nassisi, V.; Delle Side, D.

    2015-04-01

    A complete review of the essential and recent developments in the field of post-acceleration of laser-induced ion beams is presented. After a brief introduction to the physics of low-intensity nanosecond laser-matter interaction, the details of ions extraction and acceleration are critically analyzed and the key parameters to obtain good-quality ion beams are illustrated. A description of the most common ion beam diagnosis system is given, together with the associated analytical techniques.

  16. Laser cooling of relativistic heavy-ion beams for FAIR

    NASA Astrophysics Data System (ADS)

    Winters, D.; Beck, T.; Birkl, G.; Dimopoulou, C.; Hannen, V.; Kühl, Th; Lochmann, M.; Loeser, M.; Ma, X.; Nolden, F.; Nörtershäuser, W.; Rein, B.; Sánchez, R.; Schramm, U.; Siebold, M.; Spiller, P.; Steck, M.; Stöhlker, Th; Ullmann, J.; Walther, Th; Wen, W.; Yang, J.; Zhang, D.; Bussmann, M.

    2015-11-01

    Laser cooling is a powerful technique to reduce the longitudinal momentum spread of stored relativistic ion beams. Based on successful experiments at the experimental storage ring at GSI in Darmstadt, of which we show some important results in this paper, we present our plans for laser cooling of relativistic ion beams in the future heavy-ion synchrotron SIS100 at the Facility for Antiproton and Ion Research in Darmstadt.

  17. Diagnostics for studies of novel laser ion acceleration mechanisms

    SciTech Connect

    Senje, Lovisa; Aurand, Bastian; Wahlström, Claes-Göran; Yeung, Mark; Kuschel, Stephan; Rödel, Christian; Wagner, Florian; Roth, Markus; Li, Kun; Neumayer, Paul; Dromey, Brendan; Jung, Daniel; Bagnoud, Vincent; Zepf, Matthew; Kuehl, Thomas

    2014-11-15

    Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution.

  18. High-charge energetic ions generated by intersecting laser pulses

    NASA Astrophysics Data System (ADS)

    Yang, L.; Deng, Z. G.; Yu, M. Y.; Wang, X. G.

    2016-08-01

    Ion acceleration from the interaction of two intersecting intense laser pulses with an overdense plasma is investigated using a three-dimensional particle-in-cell simulation. It is found that, comparing with the single-pulse case, the charge of the resulting energetic ion bunch can be increased by more than an order of magnitude without much loss of quality. Dependence of the ion charge on the interaction parameters, including separation distance and incidence angles of the lasers, is considered. It is shown that the charge of the accelerated ion bunch can be optimized by controlling the degree of laser overlapping. The improved performance can be attributed to the enhanced laser intensity as well as stochastic heating of the accelerated electrons. Since at present the intensity of readily available lasers is limited, the two pulse scheme should be useful for realizing higher laser intensity in order to achieve higher-energy target normal sheath acceleration ions.

  19. Laser-cooled bunched ion beam

    SciTech Connect

    Schiffer, J.P.; Hangst, J.S.; Nielsen, J.S.

    1995-08-01

    In collaboration with the Arhus group, the laser cooling of a beam bunched by an rf electrode was investigated at the ASTRID storage ring. A single laser is used for unidirectional cooling, since the longitudinal velocity of the beam will undergo {open_quotes}synchrotron oscillations{close_quotes} and the ions are trapped in velocity space. As the cooling proceeds the velocity spread of the beam, as well as the bunch length is measured. The bunch length decreases to the point where it is limited only by the Coulomb repulsion between ions. The measured length is slightly (20-30%) smaller than the calculated limit for a cold beam. This may be the accuracy of the measurement, or may indicate that the beam still has a large transverse temperature so that the longitudinal repulsion is less than would be expected from an absolutely cold beam. Simulations suggest that the coupling between transverse and longitudinal degrees of freedom is strong -- but this issue will have to be resolved by further measurements.

  20. Influence of the gaseous mixture composition on accuracy of molecular iodine on-line detection by laser-induced fluorescence method

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Shnyrev, S. L.

    2016-07-01

    This paper informs on research into the influence of the composition of gaseous mixtures analyzed on the accuracy of on-line molecular iodine detection by laser-induced fluorescence in various gaseous media—in atmospheric air and in technological mixtures formed during reprocessing of spent nuclear fuel. The paper shows that by considering the composition of buffer media and parts of its components, the accuracy of iodine content measurement may be increased in several times.

  1. On-line molecular iodine isotopologue detection in gaseous media during spent nuclear fuel reprocessing using a laser-induced fluorescence method

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Shnyrev, S. L.

    2015-06-01

    The paper reports on on-line measurement of the {}129{{\\text{I}}2}, 127I129I, and {}127{{\\text{I}}2} concentrations during spent nuclear fuel (SNF) reprocessing using a laser-induced fluorescence method. A He-Ne laser (632.8 nm) was used as a fluorescence excitation source. The detection limits obtained for molecular iodine isotopologue concentrations demonstrate the possibility of using this method for iodine control both in gaseous technological media generated during SNF reprocessing and after passing through the gas purification system (in atmosphere emission).

  2. Interaction of plasmas in laser ion source with double laser system

    SciTech Connect

    Fuwa, Y.; Ikeda, S.; Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Tokyo ; Kumaki, M.; Research Institute for Science and Engineering, Waseda University, Shinjuku, Tokyo ; Sekine, M.; Department of Nuclear Engineering, Tokyo Institute of Technology, Meguro, Tokyo ; Cinquegrani, D.; Romanelli, M.; Kanesue, T.; Okamura, M.; Iwashita, Y.

    2014-02-15

    Multiple laser shots could be used to elongate an ion beam pulse width or to intensify beam current from laser ion sources. In order to confirm the feasibility of the multiple shot scheme, we investigated the properties of plasmas produced by double laser shots. We found that when the interval of the laser shots is shorter than 10 μs, the ion current profile had a prominent peak, which is not observed in single laser experiments. The height of this peak was up to five times larger than that of single laser experiment.

  3. Laser Induced Fluorescence of the Iodine Ion

    NASA Astrophysics Data System (ADS)

    Hargus, William

    2014-10-01

    Iodine (I2) has been considered as a potential electrostatic spacecraft thruster propellant for approximately 2 decades, but has only recently been demonstrated. Energy conversion efficiency appears to be on par with xenon without thruster modification. Intriguingly, performance appears to exceed xenon at high acceleration potentials. As part of a continuing program for the development of non-intrusive plasma diagnostics for advanced plasma spacecraft propulsion, we have identified the I II 5d5D4 o state as metastable, and therefore containing a reservoir of excited state ions suitable for laser probing. The 5d5D4 o - 6p5P3 transition at 695.878 nm is convenient for diode laser excitation with the 5s5S2 o - 6p5P3 transition at 516.12 nm as an ideal candidate for non-resonant fluorescence collection. We have constructed a Penning type iodine microwave discharge lamp optimized for I II production for table-top measurements. This work demonstrates I II laser-induced fluorescence in a representative iodine discharge and will validate our previous theoretical work based on the limited available historical I II spectral data.

  4. On-Line/At-Line Technetium Monitor Using Scintillating Ion Exchange Resins for the Savannah River Site

    SciTech Connect

    Wach, S.T.

    2000-08-30

    The results of this study indicate that the combination of extraction chromatography and on-line flow-cell scintillation counting can exceed a 99Tc detection limit of 0.005 Ci/mL in the presence of 90Sr, 137Cs, and 239Pu in less than an 18 minute analysis time.

  5. Laser photoelectron spectroscopy of ions. Progress report

    SciTech Connect

    Ellison, G.B.

    1992-01-16

    This enterprise uses photoelectron spectroscopy to study the properties of negative ions and radicals. The essence of our experiment is to cross a 0.6 keV mass-selected ion beam (M{sup {minus}}) with the output of a CW laser, {Dirac_h}{omega}{sub o}. The resultant detached photoelectrons with kinetic energy, KE, are energy analyzed by means of a set of electrostatic hemispherical analyzers. Analysis of the photoelectron spectra enables us to extract molecular electron affinities, vibrational frequencies and electronic splittings of the final radical, M, as well as the relative molecular geometries of ions (M{sup {minus}}) and radicals (M). We have scrutinized the two simplest nitrenes: methylnitrene (CH{sub 3}N) and phenylnitrene (C{sub 6}H{sub 5}N). By preparing the corresponding anions, CH{sub 3}N{sup {minus}} and C{sub 6}H{sub 5}N{sup {minus}}, we have studied these nitrene biradicals. Singlet methylnitrene is especially interesting since it is formally a ``transition state.``

  6. Shaping laser accelerated ions for future applications - The LIGHT collaboration

    NASA Astrophysics Data System (ADS)

    Busold, S.; Almomani, A.; Bagnoud, V.; Barth, W.; Bedacht, S.; Blažević, A.; Boine-Frankenheim, O.; Brabetz, C.; Burris-Mog, T.; Cowan, T. E.; Deppert, O.; Droba, M.; Eickhoff, H.; Eisenbarth, U.; Harres, K.; Hoffmeister, G.; Hofmann, I.; Jaeckel, O.; Jaeger, R.; Joost, M.; Kraft, S.; Kroll, F.; Kaluza, M.; Kester, O.; Lecz, Z.; Merz, T.; Nürnberg, F.; Al-Omari, H.; Orzhekhovskaya, A.; Paulus, G.; Polz, J.; Ratzinger, U.; Roth, M.; Schaumann, G.; Schmidt, P.; Schramm, U.; Schreiber, G.; Schumacher, D.; Stoehlker, T.; Tauschwitz, A.; Vinzenz, W.; Wagner, F.; Yaramyshev, S.; Zielbauer, B.

    2014-03-01

    The generation of intense ion beams from high-intensity laser-generated plasmas has been the focus of research for the last decade. In the LIGHT collaboration the expertise of heavy ion accelerator scientists and laser and plasma physicists has been combined to investigate the prospect of merging these ion beams with conventional accelerator technology and exploring the possibilities of future applications. We report about the goals and first results of the LIGHT collaboration to generate, handle and transport laser driven ion beams. This effort constitutes an important step in research for next generation accelerator technologies.

  7. On-line capillary electrophoresis/microelectrospray ionization-tandem mass spectrometry using an ion trap storage/time-of-flight mass spectrometer with SWIFT technology.

    PubMed

    Jin, X; Kim, J; Parus, S; Lubman, D M; Zand, R

    1999-08-15

    The development of a system capable of the speed required for on-line capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) of tryptic digests is described. The ion trap storage/reflectron time-of-flight (IT/reTOF) mass spectrometer is used as a nonscanning detector for rapid CE separation, where the peptides are ionized on-line using electrospray ionization (ESI). The ESI produced ions are stored in the ion trap and dc pulse injected into the reTOF-MS at a rate sufficient to maintain the separation achieved by CE. Using methodology generated by software and hardware developed in our lab, we can produce SWIFT (Stored Waveform Inverse Fourier Transform) ion isolation and TICKLE activation/fragmentation voltage waveforms to generate MS/MS at a rate as high as 10 Hz so that the MS/MS spectra can be optimized on even a 1-2 s eluting peak. In CE separations performed on tryptic digests of dogfish myelin basic protein (MBP) where eluting peaks 4-8 s wide are observed, it is demonstrated that an acquisition rate of 4 Hz provides > 20 spectra/peak and is more than sufficient to provide optimized MS/MS spectra of each of the eluting peaks in the electropherogram. The detailed structural analysis of dogfish MBP including several posttranslational modifications using CE-MS and CE-MS/MS is demonstrated using this method with < 10 fmol of material consumed. PMID:10464485

  8. On-line equalization for lithium-ion battery packs based on charging cell voltages: Part 1. Equalization based on remaining charging capacity estimation

    NASA Astrophysics Data System (ADS)

    Zheng, Yuejiu; Ouyang, Minggao; Lu, Languang; Li, Jianqiu; Han, Xuebing; Xu, Liangfei

    2014-02-01

    Because of the inevitable inconsistency during manufacture and use of battery cells, cell variations in battery packs have significant impacts on battery pack capacities, durability and safety for electric vehicles (EVs). To reduce cell variations and increase pack capacity, cell equalization is essentially required. In the series of two papers, we discover that dissipative cell equalization (DCE) using dissipative resistances is a feasible on-line equalization method for battery packs in EVs. We subsequently propose on-line equalization algorithms for lithium-ion battery packs based on charging cell voltage curves (CCVCs). The objective of these algorithms is to maximize pack capacities by conditioning CCVCs. As the first paper of the series, we first briefly review equalization topologies and algorithms. We discover cell remaining charging capacity (RCC) can be on-line estimated and further propose DCE algorithm based on remaining charging capacity estimation (RCCE). We establish a pack model with 8 cells in series and simulate 4 scenes with different cell variations. RCCE-DCE algorithm is proved to be effective by comparing pack capacities with/without RCCE-DCE algorithm. The equalization capability and over-equalization prevention are further examined, and the result shows that RCCE-DCE algorithm is suitable for on-line equalization in EVs.

  9. Magnetic plasma confinement for laser ion source.

    PubMed

    Okamura, M; Adeyemi, A; Kanesue, T; Tamura, J; Kondo, K; Dabrowski, R

    2010-02-01

    A laser ion source (LIS) can easily provide a high current beam. However, it has been difficult to obtain a longer beam pulse while keeping a high current. On occasion, longer beam pulses are required by certain applications. For example, more than 10 micros of beam pulse is required for injecting highly charged beams to a large sized synchrotron. To extend beam pulse width, a solenoid field was applied at the drift space of the LIS at Brookhaven National Laboratory. The solenoid field suppressed the diverging angle of the expanding plasma and the beam pulse was widened. Also, it was observed that the plasma state was conserved after passing through a few hundred gauss of the 480 mm length solenoid field. PMID:20192365

  10. Hot-cavity studies for the Resonance Ionization Laser Ion Source

    NASA Astrophysics Data System (ADS)

    Henares, J. L.; Lecesne, N.; Hijazi, L.; Bastin, B.; Kron, T.; Lassen, J.; Le Blanc, F.; Leroy, R.; Osmond, B.; Raeder, S.; Schneider, F.; Wendt, K.

    2016-09-01

    The Resonance Ionization Laser Ion Source (RILIS) has emerged as an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability, and ability to ionize target elements efficiently and element selectively. GISELE is an off-line RILIS test bench to study the implementation of an on-line laser ion source at the GANIL separator facility. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. The ion source geometry was tested in several configurations in order to find a solution with optimal ionization efficiency and beam emittance. Furthermore, a low work function material was tested to reduce the contaminants and molecular sidebands generated inside the ion source. First results with ZrC ionizer tubes will be presented. Furthermore, a method to measure the energy distribution of the ion beam as a function of the time of flight will be discussed.

  11. Sequential on-line C-terminal sequencing of peptides based on carboxypeptidase Y digestion and optically gated capillary electrophoresis with laser-induced fluorescence detection.

    PubMed

    Tian, Miaomiao; Zhang, Ning; Liu, Xiaoxia; Guo, Liping; Yang, Li

    2016-08-12

    We report a novel method for sequential on-line C-terminal sequencing of peptides, which combines carboxypeptidase Y (CPY) digestion with on-line derivatization and optically gated capillary electrophoresis with laser-induced fluorescence detection (OGCE-LIF). Various factors that may affect the C-terminal sequencing were investigated and optimized. High repeatability of on-line derivatization and the sequential OGCE-LIF assay of amino acids (AAs) was achieved with relative standard deviation (RSD) (n=20) less than 1.5% and 3.2% for migration time and peak height, respectively. A total of 13 AAs was efficiently separated in the present study, indicating that the method can be used for sequencing of peptides consisting of the 13 AAs studied. Using two synthesized N-terminally blocked peptides as test examples, we show that the present method can on-line monitor the released AAs with a temporal resolution of 50s during the entire CPY digestion process. The rates of AA release as a function of digestion time were easily measured; thus, the AA sequence of the peptide was determined with just one OGCE assay. Our study indicates the present approach is an effective, reliable, and convenient method for rapid analysis of the C-terminal sequence of peptides, with potential application in peptide analysis and proteome research. PMID:27425760

  12. Laser-driven multicharged heavy ion beam acceleration

    NASA Astrophysics Data System (ADS)

    Nishiuchi, M.; Sakaki, H.; Esirkepov, T. Z.; Nishio, K.; Pikuz, T. A.; Faenov, A. Y.; Pirozhkov, A. S.; Sagisaka, A.; Ogura, K.; Kanasaki, M.; Kiriyama, H.; Fukuda, Y.; Kando, M.; Yamauchi, T.; Watanabe, Y.; Bulanov, S. V.; Kondo, K.; Imai, K.; Nagamiya, S.

    2015-05-01

    Experimental demonstration of multi-charged heavy ion acceleration from the interaction between the ultra-intense short pulse laser system and the metal target is presented. The laser pulse of <10 J laser energy, 36 fs pulse width, and the contrast level of ~1010 from 200 TW class Ti:sapphire J-KAREN laser system at JAEA is used in the experiment. Almost fully stripped Fe ions accelerated up to 0.9 GeV are demonstrated. This is achieved by the high intensity laser field of ˜ 1021Wcm-2 interacting with the solid density target. The demonstrated iron ions with high charge to mass ratio (Q/M) is difficult to be achieved by the conventional heavy ion source technique in the accelerators.

  13. Relativistic laser piston model: Ponderomotive ion acceleration in dense plasmas using ultraintense laser pulses

    NASA Astrophysics Data System (ADS)

    Schlegel, T.; Naumova, N.; Tikhonchuk, V. T.; Labaune, C.; Sokolov, I. V.; Mourou, G.

    2009-08-01

    Laser ponderomotive force at superhigh intensities provides an efficient ion acceleration in bulk dense targets and evacuates a channel enabling further laser beam propagation. The developed quasistationary model of a laser piston—a double layer structure supported by the radiation pressure—predicts the general parameters of the acceleration process in homogeneous and inhomogeneous overdense plasmas. Particle-in-cell simulations confirm the estimated characteristics in a wide range of laser intensities and ion densities and show advantages of circularly polarized laser pulses. Two nonstationary effects are identified in the simulations. First, oscillations of the piston velocity and of the thickness of the ion charge separation layer broaden the energy spectrum of accelerated ions. Second, the electrons accelerated toward the incoming laser wave emit strong high-frequency radiation, enabling a cooling effect, which helps to sustain high charge neutrality in the piston and to maintain an efficient ion acceleration.

  14. On-line and post irradiation analysis of swift heavy ion induced modification of PMMA (polymethyl-methacrylate)

    NASA Astrophysics Data System (ADS)

    Hossain, U. H.; Lima, V.; Baake, O.; Severin, D.; Bender, M.; Ensinger, W.

    2014-05-01

    The present work is part of a research program studying the swift heavy ion induced modification of aliphatic polymers with some comparable side groups, here polymethyl-methacrylate (PMMA). This paper presents a study on Fourier-transform-infrared spectroscopy (FTIR), residual gas analysis (RGA), and Ultraviolet-Visible (UV-Vis) spectroscopy of the transformations of a PMMA film under gold (Au) and uranium (U) ion irradiation in the MeV/u range in vacuum to fluences up to 3 × 1011 ions per cm2. The results show a general ion induced degradation of the polymer, with release of volatile fragments, scission of side chains and polymeric backbone, formation of conjugated double bonds, and the resulting increased absorption of the UV part in the UV-Vis spectral region. A molecular scission mechanism which explains the main degradation products is proposed.

  15. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.

    PubMed

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Hua, Lei; Li, Haiyang

    2016-06-01

    Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in ≥60% relative humidity air could be obtained at ≤79.0ng L(-1) with linear ranges of 129-2064ng L(-1). The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. PMID:27130121

  16. The on-line charge breeding program at TRIUMF's Ion Trap For Atomic and Nuclear Science for precision mass measurements

    SciTech Connect

    Simon, M. C.; Eberhardt, B.; Jang, F.; Luichtl, M.; Robertson, D.; Chaudhuri, A.; Delheij, P.; Grossheim, A.; Kwiatkowski, A. A.; Mane, E.; Pearson, M. R.; Schultz, B. E.; Bale, J. C.; Chowdhury, U.; Ettenauer, S.; Gallant, A. T.; Dilling, J.; Lennarz, A.; Ma, T.; Andreoiu, C.; and others

    2012-02-15

    TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) constitutes the only high precision mass measurement setup coupled to a rare isotope facility capable of increasing the charge state of short-lived nuclides prior to the actual mass determination in a Penning trap. Recent developments around TITAN's charge breeder, the electron beam ion trap, form the basis for several successful experiments on radioactive isotopes with half-lives as low as 65 ms and in charge states as high as 22+.

  17. On-line equalization for lithium-ion battery packs based on charging cell voltages: Part 2. Fuzzy logic equalization

    NASA Astrophysics Data System (ADS)

    Zheng, Yuejiu; Ouyang, Minggao; Lu, Languang; Li, Jianqiu; Han, Xuebing; Xu, Liangfei

    2014-02-01

    In the first part of this work, we propose dissipative cell equalization (DCE) algorithm based on remaining charging capacity estimation (RCCE) and establish a pack model with 8 cells in series. The results show that RCCE-DCE algorithm is suitable for on-line equalization in electric vehicles (EVs) and no over-equalization happens. However, 1% pack capacity difference from the DCE theoretical pack capacity is observed with RCCE-DCE algorithm. Therefore, as the second part of the series, we propose fuzzy logic (FL) DCE algorithm based on charging cell voltage curves (CCVCs). Cell capacities and SOCs are fuzzily identified in FL-DCE algorithm by comparing cell voltages at the beginning and end of charging. Adaptive FL-DCE is further improved to prevent over-equalization and maintain the equalization capability. The simulation results show that pack capacity difference from the DCE theoretical pack capacity with the adaptive FL-DCE is smaller than that with RCCE-DCE algorithm, and the duration of the infant stage is also shorter. The proposed adaptive FL-DCE is suitable for on-line equalization in EVs and well prevents over-equalization.

  18. Tunable diode laser absorption spectroscopy-based tomography system for on-line monitoring of two-dimensional distributions of temperature and H2O mole fraction

    NASA Astrophysics Data System (ADS)

    Xu, Lijun; Liu, Chang; Jing, Wenyang; Cao, Zhang; Xue, Xin; Lin, Yuzhen

    2016-01-01

    To monitor two-dimensional (2D) distributions of temperature and H2O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors' knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H2O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm-1 (1343.3 nm) and 7185.6 cm-1 (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H2O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H2O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.

  19. Time profile of ion pulses produced in a hot-cavity laser ion source

    SciTech Connect

    Liu, Y.; Beene, J. R.; Havener, C. C.; Vane, C. R.; Geppert, Ch.; Gottwald, T.; Kessler, T.; Wies, K.; Wendt, K.

    2010-02-15

    The time spreads of Mn ions produced by three-photon resonant ionization in a hot-cavity laser ion source are measured. A one-dimensional ion-transport model is developed to simulate the observed ion time structures. Assuming ions are generated with a Maxwellian velocity distribution and are guided by an axial electric field, the predictions of the model agree reasonably well with the experimental data and suggest that the ions are radially confined in the ion source and a substantial fraction of the ions in the transport tube are extracted.

  20. Time Profile of Ion Pulses Produced in a Hot-Cavity Laser Ion Source

    SciTech Connect

    Liu, Yuan; Beene, James R; Havener, Charles C; Vane, C Randy; Geppert, C.; Gottwald, T.; Kessler, T.; Wies, K.; Wendt, K.

    2010-01-01

    The time spreads of Mn ions produced by three-photon resonant ionization in a hot-cavity laser ion source are measured. A one-dimensional ion-transport model is developed to simulate the observed ion time structures. Assuming ions are generated with a Maxwellian velocity distribution and are guided by an axial electric field, the predictions of the model agree reasonably well with the experimental data and suggest that the ions are radially confined in the ion source and a substantial fraction of the ions in the transport tube are extracted.

  1. Numerical analysis of 50 Gbaud homodyne coherent receivers relying on line-coding and injection locking in lasers

    NASA Astrophysics Data System (ADS)

    Xydas, Yannis; Ressopoulos, Constantinos; Bogris, Adonis

    2015-12-01

    We present a numerical analysis of 50 Gbaud coherent detection enabled by injection locked lasers and line coding. The coherent receiver was tested with respect to an ideal receiver for two higher order modulation formats (16-QAM, QPSK) and under diverse operating regimes relating to the slave laser linewidth properties, the injection level and the frequency detuning between the incoming signal and the slave laser. The impact of the slave laser properties and line coding techniques on the receiver performance is highlighted showing that the technique could be used as a practical solution in order to enable low-cost and short reach n × 100 Gb/s Ethernet communication systems with the potential of flexibility in terms of the data rate.

  2. Intense ion beams accelerated by ultra-intense laser pulses

    NASA Astrophysics Data System (ADS)

    Roth, Markus; Cowan, T. E.; Gauthier, J. C.; Vehn, J. Meyer-Ter; Allen, M.; Audebert, P.; Blazevic, A.; Fuchs, J.; Geissel, M.; Hegelich, M.; Karsch, S.; Pukhov, A.; Schlegel, T.

    2002-04-01

    The discovery of intense ion beams off solid targets irradiated by ultra-intense laser pulses has become the subject of extensive international interest. These highly collimated, energetic beams of protons and heavy ions are strongly depending on the laser parameters as well as on the properties of the irradiated targets. Therefore we have studied the influence of the target conditions on laser-accelerated ion beams generated by multi-terawatt lasers. The experiments were performed using the 100 TW laser facility at Laboratoire pour l'Utilisation des Laser Intense (LULI). The targets were irradiated by pulses up to 5×1019 W/cm2 (~300 fs,λ=1.05 μm) at normal incidence. A strong dependence on the surface conditions, conductivity, shape and purity was observed. The plasma density on the front and rear surface was determined by laser interferometry. We characterized the ion beam by means of magnetic spectrometers, radiochromic film, nuclear activation and Thompson parabolas. The strong dependence of the ion beam acceleration on the conditions on the target back surface was confirmed in agreement with predictions based on the target normal sheath acceleration (TNSA) mechanism. Finally shaping of the ion beam has been demonstrated by the appropriate tailoring of the target. .

  3. Measurement of ion beam from laser ion source for RHIC EBIS.

    SciTech Connect

    Kanesue,T.; Tamura, J.; Okamura, M.

    2008-06-23

    Laser ion source (LIS) is a candidate of the primary ion source for the RHIC EBIS. LIS will provide intense charge state 1+ ions to the EBIS for further ionization. We measured plasma properties of a variety of atomic species from C to Au using the second harmonics of Nd:YAG laser (532 nm wave length, up to 0.5 J/6 ns). Since properties of laser produced plasma is different from different species, laser power density for singly charged ion production should be verified experimentally for each atomic species. After plasma analysis experiments, Au ions was extracted from plasma and emittance of the ion beam was measured using a pepper pot type emittance monitor.

  4. Intense ion beams accelerated by relativistic laser plasmas

    NASA Astrophysics Data System (ADS)

    Roth, Markus; Cowan, Thomas E.; Gauthier, Jean-Claude J.; Allen, Matthew; Audebert, Patrick; Blazevic, Abel; Fuchs, Julien; Geissel, Matthias; Hegelich, Manuel; Karsch, S.; Meyer-ter-Vehn, Jurgen; Pukhov, Alexander; Schlegel, Theodor

    2001-12-01

    We have studied the influence of the target properties on laser-accelerated proton and ion beams generated by the LULI multi-terawatt laser. A strong dependence of the ion emission on the surface conditions, conductivity, shape and material of the thin foil targets were observed. We have performed a full characterization of the ion beam using magnetic spectrometers, Thompson parabolas, radiochromic film and nuclear activation techniques. The strong dependence of the ion beam acceleration on the conditions on the target back surface was found in agreement with theoretical predictions based on the target normal sheath acceleration (TNSA) mechanism. Proton kinetic energies up to 25 MeV have been observed.

  5. On-line measurement of perchlorate in atmospheric aerosol based on ion chromatograph coupled with particle collector and post-column concentrator.

    PubMed

    Takeuchi, Masaki; Yoshioka, Kaoru; Toyama, Yusuke; Kagami, Ai; Tanaka, Hideji

    2012-08-15

    An automated analysis system has been developed for measuring perchlorate concentration in atmospheric aerosol. The perchlorate in aerosol sample, which has been collected with water mist in a hydrophobic filter/mist chamber based particle collector, is continuously preconcentrated. The matrix ions such as sulfate are subsequently removed from the preconcentrator. The remaining perchlorate is then analyzed on-line with an ion chromatograph in conjunction with a Nafion membrane tube based post-column concentrator. The sensitivity is increased by a factor of 7.7 with the post-column concentration technique. The proposed system has been successfully operated at Tokushima, Japan. The limit of detection is 0.35 ng/m(3) for 3 h sampling cycle. The perchlorate concentration in the atmospheric aerosol averaged 1.01±1.75 ng/m(3) (n=12). PMID:22841118

  6. New method of beam bunching in free-ion lasers

    SciTech Connect

    Bessonov, E.G.

    1995-12-31

    An effective ion beam bunching method is suggested. This method is based on a selective interaction of line spectrum laser light (e.g. axial mode structure light) with non-fully stripped ion beam cooled in a storage rings, arranging the ion beam in layers in radial direction of an energy-longitudinal coordinate plane and following rotation of the beam at the right angle after switching on the RF cavity or undulator grouper/buncher. Laser cooling of the ion beam can be used at this position after switching off the resonator to decrease the energy spread caused by accelerating field of the resonator. A relativistic multilayer ion mirror will be produced this way. Both monochromatic laser beams and intermediate monochromaticity and bandwidth light sources of spontaneous incoherent radiation can be used for production of hard and high power electromagnetic radiation by reflection from this mirror. The reflectivity of the mirror is rather high because of the cross-section of the backward Rayleigh scattering of photon light by non-fully stripped relativistic ions ({approximately}{lambda}{sup 2}) is much greater ({approximately} 10{divided_by}15 orders) then Thompson one ({approximately} r{sub e}{sup 2}). This position is valid even in the case of non-monochromatic laser light ({Delta}{omega}/{omega} {approximately} 10{sup -4}). Ion cooling both in longitudinal plane and three-dimensional radiation ion cooling had been proposed based on this observation. The using of these cooling techniques will permit to store high current and low emittance relativistic ion beams in storage rings. The bunched ion beam can be used in ordinary Free-Ion Lasers as well. After bunching the ion beam can be extracted from the storage ring in this case. Storage rings with zero momentum compaction function will permit to keep bunching of the ion beam for a long time.

  7. Time Profiles of Ions Produced in a Hot-Cavity Resonant Ionization Laser Ion Source

    SciTech Connect

    Liu, Yuan; Baktash, Cyrus; Beene, James R; Havener, Charles C; Krause, Herbert F; Schultz, David Robert; Stracener, Daniel W; Vane, C Randy; Geppert, C.; Kessler, T.; Wies, K.; Wendt, K.

    2011-01-01

    The time profiles of Cu, Sn and Ni ions extracted from a hot-cavity resonant ionization laser ion source are investigated. The ions are produced in the ion source by three-photon resonant ionization with pulsed Ti:Sapphire lasers. Measurements show that the time spread of these ions generated within laser pulses of about 30 ns could be larger than 100 s when the ions are extracted from the ion source. A one-dimensional ion-transport model using the Monte Carlo method is developed to simulate the time dependence of the ion pulses. The observed ion temporal profiles agree reasonably well with the predictions of the model, which indicates that a substantial fraction of the extracted ions are generated in the vapor-transfer tube rather than the hot cavity and that ion-wall collisions are suppressed inside the ion source by an undetermined ion confinement mechanism. Three-dimensional modeling will be necessary to understand the strong reduction in losses expected from ion-wall collisions which we interpret as evidence for confinement.

  8. Generation of elliptically polarized nitrogen ion laser fields using two-color femtosecond laser pulses

    PubMed Central

    Li, Ziting; Zeng, Bin; Chu, Wei; Xie, Hongqiang; Yao, Jinping; Li, Guihua; Qiao, Lingling; Wang, Zhanshan; Cheng, Ya

    2016-01-01

    We experimentally investigate generation of nitrogen molecular ion () lasers with two femtosecond laser pulses at different wavelengths. The first pulse serves as the pump which ionizes the nitrogen molecules and excites the molecular ions to excited electronic states. The second pulse serves as the probe which leads to stimulated emission from the excited molecular ions. We observe that changing the angle between the polarization directions of the two pulses gives rise to elliptically polarized laser fields, which is interpreted as a result of strong birefringence of the gain medium near the wavelengths of the laser. PMID:26888182

  9. Cluster ion control by simultaneous irradiations of femtosecond laser and nanosecond laser pulses

    NASA Astrophysics Data System (ADS)

    Kamada, H.; Hiratani, Y.; Toyoda, K.

    2002-09-01

    Generation of multiply charged ions and molecular ions have been investigated using simultaneous irradiation of high intensity and ultrashort pulse of Ti:sapphire laser and fourth harmonics of Q-switched nanosecond pulse of Nd:YAG laser on carbon targets [Morimoto et al., in: Proceedings of the 13th International Conference on High-Power Particles Beams (BEAMS2000),Vol. PB-89, Nagaoka, 2000, p. 359; Toyoda et al., in: Proceedings of the 8th International Symposium on Gas Flow and Chemical Lasers and High-Power Laser Conference (GCL-HPL2000), Vol. P1.60, 2000, p. 101]. The ion current waveforms have been analyzed by means of time-of-flight (tof) mass measurement. Simultaneous irradiation of high intensity and ultrashort pulse of Ti:sapphire laser and fourth harmonics of Q-switched nanosecond pulse of Nd:YAG laser on carbon targets was found to generate molecular ions of carbon.

  10. Laser ion source activities at Brookhaven National Laboratory

    DOE PAGESBeta

    Kanesue, Takeshi; Okamura, Masahiro

    2015-07-31

    In Brookhaven National Laboratory (BNL), we have been developing laser ion sources for diverse accelerators. Tabletop Nd:YAG lasers with up to several Joules of energy are mainly used to create ablation plasmas for stable operations. The obtained charge states depend on laser power density and target species. Two types of ion extraction schemes, Direct Plasma Injection Scheme (DPIS) and conventional static extraction, are used depending on application. We optimized and select a suitable laser irradiation condition and a beam extraction scheme to meet the requirement of the following accelerator system. We have demonstrated to accelerate more than 5 x 1010more » of C6+ ions using the DPIS. We successfully commissioned low charge ion beam provider to the user facilities in BNL. As a result, to achieve higher current, higher charge state and lower emittance, further studies will continue.« less

  11. Focusing of high-current laser-driven ion beams

    NASA Astrophysics Data System (ADS)

    Badziak, J.; Jabłoński, S.

    2007-04-01

    Using a two-dimensional relativistic hydrodynamic code, it is shown that a dense high-current ion beam driven by a short-pulse laser can be effectively focused by curving the target front surface. The focused beam parameters essentially depend on the density gradient scale length of the preplasma Ln and the surface curvature radius RT. When Ln⩽0.5λL (λL is the laser wavelength) and RT is comparable with the laser beam aperture dL, a significant fraction of the accelerated ions is focused on a spot much smaller than dL, which results in a considerable increase in the ion fluence and current density. Using high-contrast multipetawatt picosecond laser pulses of relativistic intensity (˜1020W/cm2), focused ion (proton) current densities approaching those required for fast ignition of DT fuel seem to be feasible.

  12. Laser ion source activities at Brookhaven National Laboratory

    SciTech Connect

    Kanesue, Takeshi; Okamura, Masahiro

    2015-07-31

    In Brookhaven National Laboratory (BNL), we have been developing laser ion sources for diverse accelerators. Tabletop Nd:YAG lasers with up to several Joules of energy are mainly used to create ablation plasmas for stable operations. The obtained charge states depend on laser power density and target species. Two types of ion extraction schemes, Direct Plasma Injection Scheme (DPIS) and conventional static extraction, are used depending on application. We optimized and select a suitable laser irradiation condition and a beam extraction scheme to meet the requirement of the following accelerator system. We have demonstrated to accelerate more than 5 x 1010 of C6+ ions using the DPIS. We successfully commissioned low charge ion beam provider to the user facilities in BNL. As a result, to achieve higher current, higher charge state and lower emittance, further studies will continue.

  13. Laser ablation loading of a surface-electrode ion trap

    SciTech Connect

    Leibrandt, David R.; Clark, Robert J.; Labaziewicz, Jaroslaw; Antohi, Paul; Bakr, Waseem; Brown, Kenneth R.; Chuang, Isaac L.

    2007-11-15

    We demonstrate loading of {sup 88}Sr{sup +} ions by laser ablation into a mm-scale surface-electrode ion trap. The laser used for ablation is a pulsed, frequency-tripled Nd:YAG with pulse energies of 1-10 mJ and durations of 4 ns. An additional laser is not required to photoionize the ablated material. The efficiency and lifetime of several candidate materials for the laser ablation target are characterized by measuring the trapped ion fluorescence signal for a number of consecutive loads. Additionally, laser ablation is used to load traps with a trap depth (40 meV) below where electron impact ionization loading is typically successful (> or approx. 500 meV)

  14. Towards GeV laser-driven ion acceleration

    NASA Astrophysics Data System (ADS)

    Hegelich, B. M.; Yin, L.; Albright, B. J.; Flippo, K. A.; Gautier, D. C.; Johnson, R. P.; Letzring, S.; Shah, R. C.; Shimada, T.; Fernandez, J. C.; Henig, A.; Kiefer, D.; Liechtenstein, V.; Schreiber, J.; Habs, D.; Meyer-Ter-Vehn, J.; Rykovanov, S.; Wu, H. C.

    2008-11-01

    Applications like ion-driven fast ignition (IFI) with heavy ions or laser-based hadron therapy require efficient laser-driven ion acceleration to ˜ 0.1 -- 1 GeV. The Break-Out Afterburner (BOA) [1] regime and the Phase-Stable Acceleration (PSA) [2] regime, also reported as Radiation Pressure Acceleration (RPA) [3], promise quasi-monoenergetic beams at such energies, with ˜ 10% efficiency,. This talk summarizes our joint exploratory research program in this new and exciting area, emphasizing the realization of these mechanisms with today's lasers. The laser requirements are discussed, especially pulse contrast. The first experimental results are reported. [1] L. Yin et al., Laser & Part. Beams 24, 1-8 (2006) [2] X. Zhang et al., Phys. Plasmas 14, 123108 (2007) [3] A. P. L. Robinson et al., New J. Phys. 10, 013021 (2008)

  15. Low-Energy Ions from Laser-Cooled Atoms

    NASA Astrophysics Data System (ADS)

    Shayeganrad, G.; Fioretti, A.; Guerri, I.; Tantussi, F.; Ciampini, D.; Allegrini, M.; Viteau, M.; Fuso, F.

    2016-05-01

    We report the features of an ion source based on two-color photoionization of a laser-cooled cesium beam outsourced from a pyramidal magneto-optical trap. The ion source operates in continuous or pulsed mode. At acceleration voltages below 300 V, it delivers some ten ions per bunch with a relative energy spread Δ Urms/U ≃0.032 , as measured through the retarding field-energy-analyzer approach. Space-charge effects are negligible thanks to the low ion density attained in the interaction volume. The performances of the ion beam in a configuration using focused laser beams are extrapolated on the basis of the experimental results. Calculations demonstrate that our low-energy and low-current ion beam can be attractive for the development of emerging technologies requiring the delivery of a small amount of charge, down to the single-ion level and its eventual focusing in the 10-nm range.

  16. On-line measurements of α-pinene ozonolysis products using an atmospheric pressure chemical ionisation ion-trap mass spectrometer

    NASA Astrophysics Data System (ADS)

    Warscheid, Bettina; Hoffmann, Thorsten

    An on-line technique to investigate complex organic oxidation reactions in environmental chamber experiments is presented. The method is based on the direct introduction of the chamber air into an atmospheric pressure ion source of a commercial ion-trap mass spectrometer. To demonstrate the analytical potential of the method (atmospheric pressure chemical ionisation/mass spectrometry, APCI/MS), the ozonolysis of α-pinene was investigated in a series of experiments performed in various sized reaction chambers at atmospheric pressure and 296 K in synthetic air. Investigations were focussed on the influence of the water vapour concentration on the formation of the predominant oxidation product, pinonaldehyde, derived from the α-pinene/ozone reaction. Quantification of pinonaldehyde was achieved by conducting a standard addition technique. The molar yield of pinonaldehyde was found to depend strongly on the actual water vapour concentration between <1 and 80% relative humidity. Starting with an average yield of 0.23±0.05 at dry conditions, pinonaldehyde formation was approximately doubled by reaching a yield of 0.53±0.05 at a relative humidity of around 60%. Furthermore, the formation mechanism of pinonaldehyde was investigated in greater detail using isotopically labelled water. Applying on-line APCI/MS, pinonaldehyde formation under incorporation of 18O was observed, strongly supporting the reaction of the stabilised Criegee radical with water in the gas phase as suggested by Alvarado et al. (Journal of Geophysical Research 103 (1998) 25541-25551). Furthermore, the mass spectra recorded on-line were used to perform a semi-quantitative estimation of the decomposition pathway of the primary ozonide, indicating a branching ratio of 0.35/0.65.

  17. Characteristics of laser produced plasmas and lasers for pulsed ion sources

    SciTech Connect

    Kasuya, K.; Suzuki, T.; Itoh, Y.; Kamiya, T.; Watanabe, M.; Kawakita, Y.; Shioda, K.; Kanazawa, H.

    1996-05-01

    Preliminary experiments were performed to investigate the fundamental characteristics of the laser produced plasmas and the KrF lasers for the pulsed ion beam production. (1) Lithium target was irradiated by a small e-beam pumped KrF laser and the exhausted plasmas were measured. (2) A larger KrF laser of the same kind was operated and the output characteristics were observed. (3) The mode patterns of a discharge-pumped KrF laser was also measured most recently to prepare the future target irradiation to produce ion-source plasmas. {copyright} {ital 1996 American Institute of Physics.}

  18. Design of a laser-induced breakdown spectroscopy system for on-line quality analysis of pulverized coal in power plants

    SciTech Connect

    Yin, W.B.; Zhang, L.; Dong, L.; Ma, W.G.; Jia, S.T.

    2009-08-15

    It is vitally important for a power plant to determine the chemical composition of coal prior to combustion in order to obtain optimal boiler control. In this work, a fully software-controlled laser-induced breakdown spectroscopy (LIBS) system comprising a LIBS apparatus and sampling equipment has been designed for possible application to power plants for on-line quality analysis of pulverized coal. Special attention was given to the LIBS system, the data processing methods (especially the normalization with Bode Rule/DC Level) and the specific settings (the software-controlled triggering source, high-pressure gas cleaning device, sample preparation module, sampling module, etc.), which gave the best direct measurement for C, H, Si, Na, Mg, Fe, Al, and Ti with measurement errors less than 10% for pulverized coal. Therefore, the apparatus is accurate enough to be applied to industries for on-line monitoring of pulverized coal. The method of proximate analysis was also introduced and the experimental error of A(ad) (Ash, 'ad' is an abbreviation for 'air dried') was shown in the range of 2.29 to 13.47%. The programmable logic controller (PLC) controlled on-line coal sampling equipment, which is designed based upon aerodynamics, and is capable of performing multipoint sampling and sample-preparation operation.

  19. Design of a laser-induced breakdown spectroscopy system for on-line quality analysis of pulverized coal in power plants.

    PubMed

    Yin, Wangbao; Zhang, Lei; Dong, Lei; Ma, Weiguang; Jia, Suotang

    2009-08-01

    It is vitally important for a power plant to determine the chemical composition of coal prior to combustion in order to obtain optimal boiler control. In this work, a fully software-controlled laser-induced breakdown spectroscopy (LIBS) system comprising a LIBS apparatus and sampling equipment has been designed for possible application to power plants for on-line quality analysis of pulverized coal. Special attention was given to the LIBS system, the data processing methods (especially the normalization with Bode Rule/DC Level) and the specific settings (the software-controlled triggering source, high-pressure gas cleaning device, sample-preparation module, sampling module, etc.), which gave the best direct measurement for C, H, Si, Na, Mg, Fe, Al, and Ti with measurement errors less than 10% for pulverized coal. Therefore, the apparatus is accurate enough to be applied to industries for on-line monitoring of pulverized coal. The method of proximate analysis was also introduced and the experimental error of A(ad) (Ash, 'ad' is an abbreviation for 'air dried') was shown in the range of 2.29 to 13.47%. The programmable logic controller (PLC) controlled on-line coal sampling equipment, which is designed based upon aerodynamics, and is capable of performing multipoint sampling and sample-preparation operation. PMID:19678982

  20. Laser-driven ion sources for metal ion implantation for the reduction of dry friction

    SciTech Connect

    Boody, F. P.; Juha, L.; Kralikova, B.; Krasa, J.; Laska, L.; Masek, K.; Pfeifer, M.; Rohlena, K.; Skala, J.; Straka, P.; Perina, V.; Woryna, E.; Giersch, D.; Hoepfl, R.; Kelly, J. C.; Hora, H.

    1997-04-15

    The anomalously high ion currents and very high ionization levels of laser-produced plasmas give laser-driven ion sources significant advantages over conventional ion sources. In particular, laser-driven ion sources should provide higher currents of metal ions at lower cost, for implantation into solids in order to improve their material properties such as friction. The energy and charge distributions for Pb and Sn ions produced by ablation of solid targets with {approx}25 J, {approx}300 ps iodine laser pulses, resulting in up to 48-times ionized MeV ions, as well as the optimization of focus position, are presented. Implantation of these ions into Ck-45 steel, without electrostatic acceleration, produced profiles with two regions. Almost all of the ions were implanted in a near surface region a few nm deep. However, a small but significant number of ions were implanted as deep as could be measured with Rutherford backscattering (RBS), here 150 nm for Sn and 250 nm for Pb. For the implanted ion densities and profiles achieved, no change in the coefficient of friction was measured for either ion.

  1. Selective deuterium ion acceleration using the Vulcan petawatt laser

    NASA Astrophysics Data System (ADS)

    Krygier, A. G.; Morrison, J. T.; Kar, S.; Ahmed, H.; Alejo, A.; Clarke, R.; Fuchs, J.; Green, A.; Jung, D.; Kleinschmidt, A.; Najmudin, Z.; Nakamura, H.; Norreys, P.; Notley, M.; Oliver, M.; Roth, M.; Vassura, L.; Zepf, M.; Borghesi, M.; Freeman, R. R.

    2015-05-01

    We report on the successful demonstration of selective acceleration of deuterium ions by target-normal sheath acceleration (TNSA) with a high-energy petawatt laser. TNSA typically produces a multi-species ion beam that originates from the intrinsic hydrocarbon and water vapor contaminants on the target surface. Using the method first developed by Morrison et al. [Phys. Plasmas 19, 030707 (2012)], an ion beam with >99% deuterium ions and peak energy 14 MeV/nucleon is produced with a 200 J, 700 fs, > 10 20 W / cm 2 laser pulse by cryogenically freezing heavy water (D2O) vapor onto the rear surface of the target prior to the shot. Within the range of our detectors (0°-8.5°), we find laser-to-deuterium-ion energy conversion efficiency of 4.3% above 0.7 MeV/nucleon while a conservative estimate of the total beam gives a conversion efficiency of 9.4%.

  2. Emission Characteristics and Stability of Laser Ion Sources

    SciTech Connect

    Krasa, J.; Velyhan, A.; Krousky, E.; Laska, L.; Rohlena, K.; Jungwirth, K.; Ullschmied, J.; Lorusso, A.; Velardi, L.; Nassisi, V.; Czarnecka, A.; Ryc, L.; Parys, P.; Wolowksi, J.

    2010-10-13

    A new classification of laser ion sources concerning their pulse-to-pulse reproducibility in the ion emission is proposed. In particular, we distinguish between plasmas according to the electron distribution changing its characteristics at a laser intensity threshold of 10{sup 14} W/cm{sup 2}. Well reproducible continuous pulsed ion currents are typical for the intensity below the threshold. In contrast to this plasma the 'two-temperature' plasma arising for the intensity above this threshold shows not only a separation of charges in space and time but it also shows irregular and intense outbursts of ions similar to a self pulsing instability leading to a chaos. The sequence of fast ion outbursts visible on time-of-flight spectra is sensitive to details of non-linear interaction of the sub-nanosecond laser beam with the generated plasma.

  3. Laser desorption in an ion trap mass spectrometer

    SciTech Connect

    Eiden, G.C.; Cisper, M.E.; Alexander, M.L.; Hemberger, P.H.; Nogar, N.S.

    1993-02-01

    Laser desorption in a ion-trap mass spectrometer shows significant promise for both qualitative and trace analysis. Several aspects of this methodology are discussed in this work. We previously demonstrated the generation of both negative and positive ions by laser desorption directly within a quadrupole ion trap. In the present work, we explore various combinations of d.c., r.f., and time-varying fields in order to optimize laser generated signals. In addition, we report on the application of this method to analyze samples containing compounds such as amines, metal complexes, carbon clusters, and polynuclear aromatic hydrocarbons. In some cases the ability to rapidly switch between positive and negative ion modes provides sufficient specificity to distinguish different compounds of a mixture with a single stage of mass spectrometry. In other experiments, we combined intensity variation studies with tandem mass spectrometry experiments and positive and negative ion detection to further enhance specificity.

  4. On-Line Derivatization Gas Chromatography Ion Trap Mass Spectrometry for Determination of Endocrine Disruptors in Surface Water

    SciTech Connect

    Tzing, Shin-Hwa; Chang, Jia-Yaw; Ling, Yong-Chien

    2004-03-31

    A method has been developed for the determination of endocrine disruptors (EDs) (containing hydroxyl groups) in surface water from different sources. The surface water samples from different sites including school and local dormitory sewage effluents, lake water and river water were collected and analyzed. In this method, the pretreated sample is directly analyzed by GC-MS using on-line derivatization, where tetramethylammonium hydroxide (TMA-OH) was used as the derivatizing agent. Use of large-volume direct sample introduction (DSI) and co-injection of the sample and TMAOH avoids external contaminations as observed in conventional derivatization protocols. Additionally, the use of chemical ionization (CI) and CI-MS/MS could enable detection of EDs at lower concentrations and reduce the matrices' interference thereby enhancing detection sensitivity of EDs for quantification. In this work, the use of dichloromethane as CI reagent for EDs is reported for the first time and could detect EDs to concentrations as low as 0.5 pg/mL. The recovery ranged from 74 to 112 % and the relative standard derivations for replicate analyses ranged from 5 to 17 %. We hope that this method will be applicable for routine analysis of EDs with hydroxyl functional groups.

  5. CW silver ion laser with electron beam excitation

    NASA Astrophysics Data System (ADS)

    Wernsman, B.; Prabhuram, T.; Lewis, K.; Gonzalez, F.; Villagran, M.

    1988-08-01

    A CW laser power of 140 mW was obtained in the 840.39-nm transition of Ag II by electron-beam excitation. The electron-beam excited metal-vapor ion laser is capable of operating using metals with high vaporization temperatures, and is of interest for generation of CW coherent radiation in the 220-260-nm spectral region.

  6. Review of laser-driven ion sources and their applications.

    PubMed

    Daido, Hiroyuki; Nishiuchi, Mamiko; Pirozhkov, Alexander S

    2012-05-01

    For many years, laser-driven ion acceleration, mainly proton acceleration, has been proposed and a number of proof-of-principle experiments have been carried out with lasers whose pulse duration was in the nanosecond range. In the 1990s, ion acceleration in a relativistic plasma was demonstrated with ultra-short pulse lasers based on the chirped pulse amplification technique which can provide not only picosecond or femtosecond laser pulse duration, but simultaneously ultra-high peak power of terawatt to petawatt levels. Starting from the year 2000, several groups demonstrated low transverse emittance, tens of MeV proton beams with a conversion efficiency of up to several percent. The laser-accelerated particle beams have a duration of the order of a few picoseconds at the source, an ultra-high peak current and a broad energy spectrum, which make them suitable for many, including several unique, applications. This paper reviews, firstly, the historical background including the early laser-matter interaction studies on energetic ion acceleration relevant to inertial confinement fusion. Secondly, we describe several implemented and proposed mechanisms of proton and/or ion acceleration driven by ultra-short high-intensity lasers. We pay special attention to relatively simple models of several acceleration regimes. The models connect the laser, plasma and proton/ion beam parameters, predicting important features, such as energy spectral shape, optimum conditions and scalings under these conditions for maximum ion energy, conversion efficiency, etc. The models also suggest possible ways to manipulate the proton/ion beams by tailoring the target and irradiation conditions. Thirdly, we review experimental results on proton/ion acceleration, starting with the description of driving lasers. We list experimental results and show general trends of parameter dependences and compare them with the theoretical predictions and simulations. The fourth topic includes a review of

  7. Laser mass spectrometry of biological molecular ions produced by matrix assisted laser desorption ionization (MALDI)

    NASA Astrophysics Data System (ADS)

    Jia, W. J.; Kosmidis, C.; Ledingham, K. W. D.; Scott, C. T. J.; Singhal, R. P.

    1996-10-01

    A tandem reflectron laser mass spectrometer is used for investigations of the photo fragmentation of molecular ions. The observed fragmentation patterns for 2,5-dihydrobenzoic acid and its fragments ions are analysed. PTH-trytophan and PTH-valine ions, generated by MALDI, are photodissociated and their fragmentation pattern is discussed.

  8. Study on space charge effect in an electrostatic ion analyzer applied to measure laser produced ions

    SciTech Connect

    Jin, Q. Y.; Li, Zh. M.; Liu, W.; University of Chinese Academy of Sciences, Beijing 100049 ; Zhao, H. Y. Sha, S.; Zhang, J. J.; Zhang, X. Zh.; Sun, L. T.; Zhao, H. W.

    2014-03-15

    The abundance of different ions produced by laser ion sources is usually analyzed by an electrostatic ion analyzer (EIA). Ion current intensities in the range of several mA/cm{sup 2} at the position of the EIA have been achieved from the laser ion source developed by the Institute of Modern Physics; this indicates that a noticeable influence of space charge effect during the ion transmission will occur. Hence, while the parameters of the EIA or the beams are changed, such as ion species, current intensity, the ions’ transmission efficiency through the EIA is different, which will result in an uncertainty in the estimation of the ions’ yields. Special attention is focused on this issue in this paper. Ion's transmissions through the EIA under different circumstances are studied with simulations and experiments, the results of which are consistent with each other.

  9. Study of fluid mechanical helium argon ion laser

    NASA Technical Reports Server (NTRS)

    1972-01-01

    An approach to an argon ion laser based on gasdynamic techniques is presented. Improvement in efficiency and power output are achieved by eliminating high heat rejection problems and plasma confinement of the seal-off conventional lasers. The process of producing population inversion between the same energy levels, as in the conventional argon ion laser, has been divided into two phases by separating each other from the processes of ionization and subsequent excitation. Line drawings and graphs are included to amplify the theoretical presentation.

  10. The cooling of confined ions driven by laser beams

    SciTech Connect

    Reyna, L.G.; Sobehart, J.R.

    1993-07-01

    We finalize the dynamics of confined ions driven by a quantized radiation field. The ions can absorb photons from an incident laser beam and relax back to the ground state by either induced emissions or spontaneous emissions. Here we assume that the absorption of photons is immediately followed by spontaneous emissions, resulting in single-level ions perturbed by the exchange of momentum with the radiation field. The probability distribution of the ions is calculated using singular expansions in the low noise asymptotic limit. The present calculations reproduce the quantum results in the limit of heavy particles in static traps, and the classical results of ions in radio-frequency confining wells.

  11. Laser Driven Ion accelerators - current status and perspective

    SciTech Connect

    Zepf, M.; Robinson, A. P. L.

    2009-01-22

    The interaction of ultra-intense lasers with thin foil targets has recently emerged as a route to achieving extreme acceleration gradients and hence ultra-compact proton and ion accelerators. There are a number of distinct physical processes by which the protons/ions can be accelerated to energies in excess of 10 MeV. The recent development is discussed and a new mechanism--Radiation Pressure Acceleration is highlighted as a route to achieving efficient production of relativistic ions beams.

  12. Laser-driven ion acceleration from relativistically transparent nanotargets

    NASA Astrophysics Data System (ADS)

    Hegelich, B. M.; Pomerantz, I.; Yin, L.; Wu, H. C.; Jung, D.; Albright, B. J.; Gautier, D. C.; Letzring, S.; Palaniyappan, S.; Shah, R.; Allinger, K.; Hörlein, R.; Schreiber, J.; Habs, D.; Blakeney, J.; Dyer, G.; Fuller, L.; Gaul, E.; Mccary, E.; Meadows, A. R.; Wang, C.; Ditmire, T.; Fernandez, J. C.

    2013-08-01

    Here we present experimental results on laser-driven ion acceleration from relativistically transparent, overdense plasmas in the break-out afterburner (BOA) regime. Experiments were preformed at the Trident ultra-high contrast laser facility at Los Alamos National Laboratory, and at the Texas Petawatt laser facility, located in the University of Texas at Austin. It is shown that when the target becomes relativistically transparent to the laser, an epoch of dramatic acceleration of ions occurs that lasts until the electron density in the expanding target reduces to the critical density in the non-relativistic limit. For given laser parameters, the optimal target thickness yielding the highest maximum ion energy is one in which this time window for ion acceleration overlaps with the intensity peak of the laser pulse. A simple analytic model of relativistically induced transparency is presented for plasma expansion at the time-evolving sound speed, from which these times may be estimated. The maximum ion energy attainable is controlled by the finite acceleration volume and time over which the BOA acts.

  13. Instability-free ion acceleration by two laser pulses

    NASA Astrophysics Data System (ADS)

    Zhou, M. L.; Zhao, S.; Wang, H. Y.; Lin, C.; Lu, H. Y.; Lu, Y. R.; Tajima, T.; He, X. T.; Chen, C. E.; Gu, Y. Q.; Yan, X. Q.

    2014-05-01

    We demonstrate the instability-free ion acceleration regime by introducing laser control with two parallel circularly polarized laser pulses at an intensity of I = 6.8 × 1021 W/cm2, normally incident on a hydrogen foil. The special structure of the equivalent wave front of those two pulses, which contains Gaussian peaks in both sides and a concavity in the centre (2D), can suppress the transverse instabilities and hole boring effects to constrain a high density ion clump in the centre of the foil, leading to an acceleration over a long distance and gain above 1GeV/u for the ion bunches.

  14. Ion-implanted planar-buried-heterostructure diode laser

    DOEpatents

    Brennan, Thomas M.; Hammons, Burrell E.; Myers, David R.; Vawter, Gregory A.

    1991-01-01

    A Planar-Buried-Heterostructure, Graded-Index, Separate-Confinement-Heterostructure semiconductor diode laser 10 includes a single quantum well or multi-quantum well active stripe 12 disposed between a p-type compositionally graded Group III-V cladding layer 14 and an n-type compositionally graded Group III-V cladding layer 16. The laser 10 includes an ion implanted n-type region 28 within the p-type cladding layer 14 and further includes an ion implanted p-type region 26 within the n-type cladding layer 16. The ion implanted regions are disposed for defining a lateral extent of the active stripe.

  15. Low charge state heavy ion production with sub-nanosecond laser

    NASA Astrophysics Data System (ADS)

    Kanesue, T.; Kumaki, M.; Ikeda, S.; Okamura, M.

    2016-02-01

    We have investigated laser ablation plasma of various species using nanosecond and sub-nanosecond lasers for both high and low charge state ion productions. We found that with sub-nanosecond laser, the generated plasma has a long tail which has low charge state ions determined by an electrostatic ion analyzer even under the laser irradiation condition for highly charged ion production. This can be caused by insufficient laser absorption in plasma plume. This property might be suitable for low charge state ion production. We used a nanosecond laser and a sub-nanosecond laser for low charge state ion production to investigate the difference of generated plasma using the Zirconium target.

  16. Manipulating electron-ion recollision in a midinfrared laser field

    NASA Astrophysics Data System (ADS)

    Zheng, Yinghui; Diao, Hanhu; Zeng, Zhinan; Ge, Xiaochun; Li, Ruxin; Xu, Zhizhan

    2015-09-01

    As one of the most important physical processes of strong-field laser-matter interaction, laser-driven electron-ion recollision depends sensitively on the polarization of the laser field and can be effectively manipulated via an orthogonally polarized two-color (OTC) laser field. Here we present an extension of recollision manipulation in an OTC field to the midinfrared laser field regime, and demonstrate that only a few recollisions occur in a multicycle 1800 /900 nm OTC laser field. The number of recollisions can be controlled by simply tuning the relative delay of the two-color laser pulses, and this manipulation process can be visualized by measuring the high-order harmonic spectra. When the intensity of a midinfrared OTC field is further increased, a single recollision can be correlated to one hump in the harmonic spectrum, which will help to increase the measurement accuracy of time-resolved dynamics in atoms and molecules.

  17. Tandem ion mobility spectrometry coupled to laser excitation

    SciTech Connect

    Simon, Anne-Laure; Choi, Chang Min; Clavier, Christian; Barbaire, Marc; Maurelli, Jacques; Dagany, Xavier; MacAleese, Luke; Dugourd, Philippe; Chirot, Fabien

    2015-09-15

    This manuscript describes a new experimental setup that allows to perform tandem ion mobility spectrometry (IMS) measurements and which is coupled to a high resolution time-of-flight mass spectrometer. It consists of two 79 cm long drift tubes connected by a dual ion funnel assembly. The setup was built to permit laser irradiation of the ions in the transfer region between the two drift tubes. This geometry allows selecting ions according to their ion mobility in the first drift tube, to irradiate selected ions, and examine the ion mobility of the product ions in the second drift tube. Activation by collision is possible in the same region (between the two tubes) and between the second tube and the time-of-flight. IMS-IMS experiments on Ubiquitin are reported. We selected a given isomer of charge state +7 and explored its structural rearrangement following collisional activation between the two drift tubes. An example of IMS-laser-IMS experiment is reported on eosin Y, where laser irradiation was used to produce radical ions by electron photodetachment starting from doubly deprotonated species. This allowed measuring the collision cross section of the radical photo-product, which cannot be directly produced with an electrospray source.

  18. Note: A pulsed laser ion source for linear induction accelerators

    SciTech Connect

    Zhang, H.; Zhang, K.; Shen, Y.; Jiang, X.; Dong, P.; Liu, Y.; Wang, Y.; Chen, D.; Pan, H.; Wang, W.; Jiang, W.; Long, J.; Xia, L.; Shi, J.; Zhang, L.; Deng, J.

    2015-01-15

    We have developed a high-current laser ion source for induction accelerators. A copper target was irradiated by a frequency-quadrupled Nd:YAG laser (266 nm) with relatively low intensities of 10{sup 8} W/cm{sup 2}. The laser-produced plasma supplied a large number of Cu{sup +} ions (∼10{sup 12} ions/pulse) during several microseconds. Emission spectra of the plasma were observed and the calculated electron temperature was about 1 eV. An induction voltage adder extracted high-current ion beams over 0.5 A/cm{sup 2} from a plasma-prefilled gap. The normalized beam emittance measured by a pepper-pot method was smaller than 1 π mm mrad.

  19. Note: A pulsed laser ion source for linear induction accelerators

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Zhang, K.; Shen, Y.; Jiang, X.; Dong, P.; Liu, Y.; Wang, Y.; Chen, D.; Pan, H.; Wang, W.; Jiang, W.; Long, J.; Xia, L.; Shi, J.; Zhang, L.; Deng, J.

    2015-01-01

    We have developed a high-current laser ion source for induction accelerators. A copper target was irradiated by a frequency-quadrupled Nd:YAG laser (266 nm) with relatively low intensities of 108 W/cm2. The laser-produced plasma supplied a large number of Cu+ ions (˜1012 ions/pulse) during several microseconds. Emission spectra of the plasma were observed and the calculated electron temperature was about 1 eV. An induction voltage adder extracted high-current ion beams over 0.5 A/cm2 from a plasma-prefilled gap. The normalized beam emittance measured by a pepper-pot method was smaller than 1 π mm mrad.

  20. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    USGS Publications Warehouse

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  1. Theoretical study on line source laser-induced surface acoustic waves in two-layer structure in ablative regime

    NASA Astrophysics Data System (ADS)

    Shen, Z. H.; Xu, B. Q.; Ni, X. W.; Lu, J.; Zhang, S. Y.

    2004-03-01

    The generation of ultrasound in film-substrate system by a laser line source is studied in the case of ablation mechanism, which can be realized by adding a liquid layer at the excitation point. The time domain displacement can be yielded by the numerical jointed inversed Laplace-Fourier transformation technique. The typical surface acoustic waves (SAW) of two layer structures, slow film on fast substrate and fast film on slow substrate, are obtained and the effect of the propagation distance and the thickness of the film on the SAW are given.

  2. Multiple ionization bursts in laser-driven hydrogen molecular ion.

    PubMed

    Takemoto, Norio; Becker, Andreas

    2010-11-12

    Theoretical study on H2(+) in an intense infrared laser field on the attosecond time scale reveals that the molecular ion shows multiple bursts of ionization within a half-cycle of the laser field oscillation, in contrast to the widely accepted tunnel ionization picture for an atom. These bursts are found to be induced by transient localization of the electron at one of the nuclei, and a relation between the time instants of the localization and the vector potential of the laser light is derived. A scheme is proposed to probe the localization dynamics by an extreme ultraviolet laser pulse. PMID:21231228

  3. Determination of Ag, Tl, and Pb in few milligrams of platinum nanoclusters by on-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Becker, J. Sabine; Pickhardt, Carola; Pompe, W.

    2004-09-01

    A new analysis procedure for determination of trace impurities in a few milligram noble metal nanoclusters, using on-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was developed. During the laser ablation of investigated sample simultaneous the dry aerosol of nebulized enriched isotope spike solution was added and mixed in the laser ablation chamber. The capability of solution-based calibration by a modified isotope dilution analysis in LA-ICP-MS for the determination of selected elements was tested, using platinum reference material NIST SRM 681. A good agreement of measured with certified concentration for Ag and Pb was found. The detection limits for trace element determination of the developed analytical technique, using LA-ICP-MS with quadrupole analyzer varied between 6 ng g-1 for Ag and 90 ng g-1 for Pb. The analytical technique was applied for the determination of Ag, Tl, and Pb in a few milligram of platinum nanoclusters.

  4. AISI/DOE Advanced Process Control Program Vol. 4 of 6: ON-LINE, NON-DESTRUCTIVE MECHANICAL PROPERTY MEASUREMENT USING LASER-ULTRASOUND

    SciTech Connect

    Andre' Moreau; Martin Lord; Daniel Levesqure; Marc Dubois; Jean Bussiere; Jean-Pierre Monchalin; Christian Padioleau; Guy Lamouche; Teodor Veres; Martin Viens; Harold Hebert; Pierre Basseras; Cheng-Kuei Jen

    2001-03-31

    The goal of this project was to demonstrate the feasibility to measure the mechanical properties, such as yield strength, tensile strength, elongation, strain hardening exponent and plastic strain ratio parameters, of low carbon steel sheets on the production line using laser ultrasound. The ultrasound generated by the developed apparatus travels mostly back and forth in the thickness of the steel sheet. By measuring the time delay between two echoes, and the relative amplitude of these two echoes, one can measure ultrasound velocity and attenuation. These are governed by the microstructure: grain size, crystallographic texture, dislocations, etc. Thus, by recording the time behavior of the ultrasonic signal, one can extract microstructural information. These microstructural information together with the modified Hall-Petch equation allow measurement of the mechanical properties. Through laboratory investigations with a laboratory laser ultrasound system, followed by the installation of a prototype system at LTV Steel Company's No.1 Inspection Line in Cleveland, all target mechanical properties of ultra low carbon (ULC), low carbon (LC) and high strength low alloy (HSLA) steel sample lots were measured meeting or nearly meeting all the target accuracies. Thus, the project realized its goal to demonstrate that the mechanical properties of low carbon steel sheets can be measured on-line using laser ultrasound

  5. Storage of ions from laser-produced plasmas

    NASA Technical Reports Server (NTRS)

    Knight, R. D.

    1981-01-01

    A method of storing large numbers of metal ions created in laser-produced plasmas is presented. The outer electrode of the electrostatic ion trap is designed to give a harmonic axial potential. The ions trapped by the technique included Be(+), C(+), Al(+), Fe(+), and Pb(+). The initial number of ions stored (2 x 10 to the 8th) appeared to be the trap maximum since increasing the laser power beyond 2-3 MW did not change the ion number. An initial rapid decay in the 30-50 msec range was generally followed by a long tail at the 10% level with times greater than 100 msec. The technique should be valuable for refractory elements which cannot be easily vaporized for electron impact ionization.

  6. Ion microscopy based on laser-cooled cesium atoms.

    PubMed

    Viteau, M; Reveillard, M; Kime, L; Rasser, B; Sudraud, P; Bruneau, Y; Khalili, G; Pillet, P; Comparat, D; Guerri, I; Fioretti, A; Ciampini, D; Allegrini, M; Fuso, F

    2016-05-01

    We demonstrate a prototype of a Focused Ion Beam machine based on the ionization of a laser-cooled cesium beam and adapted for imaging and modifying different surfaces in the few-tens nanometer range. Efficient atomic ionization is obtained by laser promoting ground-state atoms into a target excited Rydberg state, then field-ionizing them in an electric field gradient. The method allows obtaining ion currents up to 130pA. Comparison with the standard direct photo-ionization of the atomic beam shows, in our conditions, a 40-times larger ion yield. Preliminary imaging results at ion energies in the 1-5keV range are obtained with a resolution around 40nm, in the present version of the prototype. Our ion beam is expected to be extremely monochromatic, with an energy spread of the order of the eV, offering great prospects for lithography, imaging and surface analysis. PMID:26876642

  7. Laser ablation loading of a radiofrequency ion trap

    NASA Astrophysics Data System (ADS)

    Zimmermann, K.; Okhapkin, M. V.; Herrera-Sancho, O. A.; Peik, E.

    2012-06-01

    The production of ions via laser ablation for the loading of radiofrequency (RF) ion traps is investigated using a nitrogen laser with a maximum pulse energy of 0.17 mJ and a peak intensity of about 250 MW/cm2. A time-of-flight mass spectrometer is used to measure the ion yield and the distribution of the charge states. Singly charged ions of elements that are presently considered for the use in optical clocks or quantum logic applications could be produced from metallic samples at a rate of the order of magnitude 105 ions per pulse. A linear Paul trap was loaded with Th+ ions produced by laser ablation. An overall ion production and trapping efficiency of 10-7 to 10-6 was attained. For ions injected individually, a dependence of the capture probability on the phase of the RF field has been predicted. In the experiment this was not observed, presumably because of collective effects within the ablation plume.

  8. Development of C6+ laser ion source and RFQ linac for carbon ion radiotherapy

    NASA Astrophysics Data System (ADS)

    Sako, T.; Yamaguchi, A.; Sato, K.; Goto, A.; Iwai, T.; Nayuki, T.; Nemoto, K.; Kayama, T.; Takeuchi, T.

    2016-02-01

    A prototype C6+ injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

  9. Development of C⁶⁺ laser ion source and RFQ linac for carbon ion radiotherapy.

    PubMed

    Sako, T; Yamaguchi, A; Sato, K; Goto, A; Iwai, T; Nayuki, T; Nemoto, K; Kayama, T; Takeuchi, T

    2016-02-01

    A prototype C(6+) injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4. PMID:26932119

  10. Laser desorption lamp ionization source for ion trap mass spectrometry.

    PubMed

    Wu, Qinghao; Zare, Richard N

    2015-01-01

    A two-step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI-ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three-dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds. PMID:25601688

  11. Means and method for characterizing high power, ultra short laser pulses in a real time, on line manner

    DOEpatents

    Veligdan, James T.

    1994-01-01

    An ultra short (<10 ps), high power laser pulse is temporally characterized by a system that uses a physical measurement of a wavefront that has been altered in a known manner. The system includes a first reflection switch to remove a portion of a pulse from a beam of pulses, then includes a second reflection switch, operating in a mode that is opposite to the first reflection switch, to slice off a portion of that removed portion. The sliced portion is then directed to a measuring device for physical measurement. The two reflection switches are arranged with respect to each other and with respect to the beam of ultra short pulses such that physical measurement of the sliced portion is related to the temporal measurement of the ultra short pulse by a geometric or trigonometric relationship. The reflection switches are operated by a control pulse that is directed to impinge on each of the reflection switches at a 90.degree. angle of incidence.

  12. Detection and quantification of sulfur in oil products by laser-induced breakdown spectroscopy for on-line analysis

    NASA Astrophysics Data System (ADS)

    Trichard, F.; Forquet, V.; Gilon, N.; Lienemann, C.-P.; Baco-Antoniali, F.

    2016-04-01

    Determination of sulfur in petroleum products is described using Laser Induced breakdown spectroscopy (LIBS). A study of buffer gases employed to improve sulfur IR line detection is presented. Optimisation of the flow rate led to a 1.4 L/min optimal helium flow rate. An adaptation between a typical laboratory setup to a compact system allowed to obtain detection limits in the 0.2% w/w range. Calibration is made under the process conditions (70 °C) and at room temperature. Normalization with a helium emission line compensates for liquid level variations and for the temperature variations. The analysis of a sample over the course of 2 days under the conditions of the industrial process was tested and gave a good repeatability.

  13. Quantification Of Cesium In Negative Hydrogen Ion Sources By Laser Absorption Spectroscopy

    SciTech Connect

    Fantz, U.; Wimmer, Ch.

    2011-09-26

    The use of cesium in negative hydrogen ion sources and the resulting cesium dynamics caused by the evaporation and redistribution in the vacuum and plasma phase makes a reliable and on-line monitoring of the cesium amount in the source highly desirable. For that purpose, a robust and compact laser absorption setup suitable for the ion source environment has been developed utilizing the Cs D{sub 2} resonance line at 852.1 nm. First measurements are taken in a small laboratory plasma chamber with cesium evaporation. A detection limit of {approx_equal}5x10{sup 13} m{sup -3} at a typical path length of 15 cm has been obtained with a dynamic range of more than three orders of magnitude, limited by line saturation at high densities. For on-line monitoring an automatic data analysis is established achieving a temporal resolution of 100 ms. The setup has then been applied to the ITER prototype ion sources developed at IPP. It is been shown that the method is well suited for routine measurements revealing a new insight into the cesium dynamics during source operation and cesium conditioning.

  14. Ion Beam Analysis applied to laser-generated plasmas

    NASA Astrophysics Data System (ADS)

    Cutroneo, M.; Macková, A.; Havranek, V.; Malinsky, P.; Torrisi, L.; Kormunda, M.; Barchuk, M.; Ullschmied, J.; Dudzak, R.

    2016-04-01

    This paper presents the research activity on Ion Beam Analysis methods performed at Tandetron Laboratory (LT) of the Institute of Nuclear Physics AS CR, Rez, Czech Republic. Recently, many groups are paying attention to implantation by laser generated plasma. This process allows to insert a controllable amount of energetic ions into the surface layers of different materials modifying the physical and chemical properties of the surface material. Different substrates are implanted by accelerated ions from plasma through terawatt iodine laser, at nominal intensity of 1015 W/cm2, at the PALS Research Infrastructure AS CR, in the Czech Republic. This regime of the laser matter interaction generates, multi-MeV proton beams, and multi-charged ions that are tightly confined in time (hundreds ps) and space (source radius of a few microns). These ion beams have a much lower transverse temperature, a much shorter duration and a much higher current than those obtainable from conventional accelerators. The implementation of protons and ions acceleration driven by ultra-short high intensity lasers is exhibited by adopting suitable irradiation conditions as well as tailored targets. An overview of implanted targets and their morphological and structural characterizations is presented and discussed.

  15. Perveance and ion bunch structure from a 'compact, high-pressure' laser ion source

    SciTech Connect

    Yeates, P.; Costello, J. T.; Kennedy, E. T.

    2010-12-15

    The Dublin City University (DCU) laser ion source (LIS) is a 'compact high-pressure' laser ion source utilizing a table top Q-switched laser. The DCU-LIS combines high laser fluence (F>4 kJ cm{sup -2}), high laser intensity (I>10{sup 11} W cm{sup -2}) with a short field free region (L=48 mm) and high source potential (V{sub ext}>40 kV) in order to offset recombination losses within the plasma and maximize the proportion of highly charged ions which are extracted from the plasma plume. Such a configuration also provides high peak currents (I{sub p}>3 mA), high current densities (J>5 mA cm{sup -2}), and high charge states (Cu{sup 6+}) in the extracted ion-bunch train. However, to obtain and utilize these parameter values in a high pressure LIS requires characterization and control of a number of processes related to ion dynamics and space charge effects on the extracted ions at the plasma plume-anode-extraction gap interface. Relevant issues include electric field distortion, Debye shielding, beam divergence, overfocusing, and perveance (P) in addition to current density profiles for the extracted ion beam. In this paper we focus on these issues and their impact on charge particle extraction and acceleration with a view to elucidating the parameter regimes within which the DCU-LIS performance envelope is optimal.

  16. Ion extraction from positively biased laser-ablation plasma

    NASA Astrophysics Data System (ADS)

    Isono, Fumika; Nakajima, Mitsuo; Hasegawa, Jun; Horioka, Kazuhiko

    2016-07-01

    Ions were extracted through a grounded grid from a positively biased laser-ablation plasma and the behaviors were investigated. Since the plasma was positively biased against the grounded wall, we could extract the ions without insulated gap. We confirmed formation of a virtual anode when we increased the distance between the grid and the ion collector. Results also indicated that when the ion flux from the ablation plasma exceeded a critical value, the current was strongly suppressed to the space charge limited level due to the formation of virtual anode.

  17. New on-line method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

    NASA Astrophysics Data System (ADS)

    Affolter, S.; Fleitmann, D.; Leuenberger, M.

    2014-01-01

    A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us to simultaneously measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the on-line water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δD reliability. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water resulting in an artificial water background with well-known δD and δ18O values. The speleothem sample is placed into a copper tube, attached to the line and after system stabilisation is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain δD and δ18O isotopic composition of measured water aliquots. Precision is better than 1.5‰ for δD and 0.4‰ for δ18O for water measurement for an extended range (-210 to 0‰ for δD and -27 to 0‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to Isotope Ratio Mass Spectrometry (IRMS) technique.

  18. Confinement of laser plasma by solenoidal field for laser ion source

    SciTech Connect

    Okamura, M.; Kanesue,T.; Kondo, K.; Dabrowski, R.

    2010-05-23

    A laser ion source can provide high current, highly charged ions with a simple structure. However, it was not easy to control the ion pulse width. To provide a longer ion beam pulse, the plasma drift length, which is the distance between laser target and extraction point, has to be extended and as a result the plasma is diluted severely. Previously, we applied a solenoid field to prevent reduction of ion density at the extraction point. Although a current enhancement by a solenoid field was observed, plasma behavior after a solenoid magnet was unclear because plasma behavior can be different from usual ion beam dynamics. We measured a transverse ion distribution along the beam axis to understand plasma motion in the presence of a solenoid field.

  19. Laser-based studies with an ion-trap mass spectrometer: Ion tomography and analytical applications

    NASA Astrophysics Data System (ADS)

    Alexander, M. L.; Cisper, M. E.; Hemberger, P. H.; Nogar, N. S.; Williams, J. D.; Syka, J. E. P.

    The iron trap mass spectrometer (ITMS) is an ion storage device which consists of two hyperbolic endcaps and a hyperbolic ring electrode. This forms a trapping cavity having a volume of several cm(sup 3). An RF potential applied to the ring electrode produces a time-varying potential which can be used to trap and/or manipulate ions under controlled conditions. This device has been used in ion trapping studies for a number of years. More recently, a commercial version has been produced and sold which allows for mass-selective ejection of trapped ions, with subsequent detection by an electron multiplier. In this mode, it operates as a compact, high efficiency, high resolution mass spectrometer. The instrument has found applications in GC/MS, in tandem mass spectroscopy and in portable mass spectral analysis. In this manuscript, we present a survey of recent results incorporating laser desorption, ionization, or photodissociation with ITMS. In one instance, we describe the use of laser photodissociation to map the spatial distribution of trapped ions in the ITMS. In this tomographic study, we have parameterized the effects of trapping potential, buffer gas pressure, supplementary RF-potential, and laser intensity. In separate studies, laser desorption was used to generate gas phase ions in the ITMS from a solid probe, by irradiation of both neat and matrix-dissolved samples. The latter experiment produced both high molecular weight ions and significant numbers of negative ions.

  20. Means and method for characterizing high power, ultra short laser pulses in a real time, on line manner

    DOEpatents

    Veligdan, J.T.

    1994-03-08

    An ultra short (<10 ps), high power laser pulse is temporally characterized by a system that uses a physical measurement of a wavefront that has been altered in a known manner. The system includes a first reflection switch to remove a portion of a pulse from a beam of pulses, then includes a second reflection switch, operating in a mode that is opposite to the first reflection switch, to slice off a portion of that removed portion. The sliced portion is then directed to a measuring device for physical measurement. The two reflection switches are arranged with respect to each other and with respect to the beam of ultra short pulses such that physical measurement of the sliced portion is related to the temporal measurement of the ultra short pulse by a geometric or trigonometric relationship. The reflection switches are operated by a control pulse that is directed to impinge on each of the reflection switches at a 90[degree] angle of incidence. 8 figures.

  1. Plasma shape control by pulsed solenoid on laser ion source

    DOE PAGESBeta

    Sekine, M.; Ikeda, S.; Romanelli, M.; Kumaki, M.; Fuwa, Y.; Kanesue, T.; Hayashizaki, N.; Lambiase, R.; Okamura, M.

    2015-05-28

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. It was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled bymore » the pulsed magnetic field. Thus, this approach may also be useful to reduce beam emittance of a LIS.« less

  2. Plasma shape control by pulsed solenoid on laser ion source

    NASA Astrophysics Data System (ADS)

    Sekine, M.; Ikeda, S.; Romanelli, M.; Kumaki, M.; Fuwa, Y.; Kanesue, T.; Hayashizaki, N.; Lambiase, R.; Okamura, M.

    2015-09-01

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. However, it was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. This approach may also be useful to reduce beam emittance of a LIS.

  3. Towards Laser Cooling Trapped Ions with Telecom Light

    NASA Astrophysics Data System (ADS)

    Dungan, Kristina; Becker, Patrick; Donoghue, Liz; Liu, Jackie; Olmschenk, Steven

    2015-05-01

    Quantum information has many potential applications in communication, atomic clocks, and the precision measurement of fundamental constants. Trapped ions are excellent candidates for applications in quantum information because of their isolation from external perturbations, and the precise control afforded by laser cooling and manipulation of the quantum state. For many applications in quantum communication, it would be advantageous to interface ions with telecom light. We present progress towards laser cooling and trapping of doubly-ionized lanthanum, which should require only infrared, telecom-compatible light. Additionally, we present progress on optimization of a second-harmonic generation cavity for laser cooling and trapping barium ions, for future sympathetic cooling experiments. This research is supported by the Army Research Office, Research Corporation for Science Advancement, and Denison University.

  4. Plasma shape control by pulsed solenoid on laser ion source

    SciTech Connect

    Sekine, M.; Ikeda, S.; Romanelli, M.; Kumaki, M.; Fuwa, Y.; Kanesue, T.; Hayashizaki, N.; Lambiase, R.; Okamura, M.

    2015-05-28

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. It was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. Thus, this approach may also be useful to reduce beam emittance of a LIS.

  5. Precision Fast Ion Beam Laser Spectroscopy of Ar{sup +}

    SciTech Connect

    Lioubimov, V.; Kolomenskii, A. A.; Schuessler, H. A.; Wada, M.; Nakamura, T.; Schury, P.; Ogawa, M.; Takamine, A.; Yamazaki, Y.; Iimura, H.; Okada, K.

    2009-03-17

    Absolute measurements of spectral lines of Ar{sup +} ions using collinear and anticollinear geometries were performed. To provide a precise reference for the laser wavelength, iodine saturation spectroscopy was applied. The precision of this reference is effected by observing the beat node between the spectroscopy laser and the corresponding mode of a femtosecond laser frequency comb. Laser-induced fluorescence allowed to perform precision frequency measurements of an Ar{sup +} transition in collinear and anticollinear geometries simultaneously; then an exact relativistic formula for the absolute transition frequency V{sub 0} = {radical}(V{sub c}V{sub a}) was used. In this geometry the influence of ion source instabilities due to pressure and anode voltage fluctuations was minimized. The result is v{sub 0} = 485,573,619.7(3) MHz, which corresponds to {delta}v/v = 6*10{sup -10}. This represents an improvement of two orders of magnitude over the previous NIST published value.

  6. Precision Fast Ion Beam Laser Spectroscopy of Ar+

    NASA Astrophysics Data System (ADS)

    Lioubimov, V.; Wada, M.; Ogawa, M.; Takamine, A.; Nakamura, T.; Schury, P.; Iimura, H.; Okada, K.; Kolomenskii, A. A.; Schuessler, H. A.; Yamazaki, Y.

    2009-03-01

    Absolute measurements of spectral lines of Ar+ ions using collinear and anticollinear geometries were performed. To provide a precise reference for the laser wavelength, iodine saturation spectroscopy was applied. The precision of this reference is effected by observing the beat node between the spectroscopy laser and the corresponding mode of a femtosecond laser frequency comb. Laser-induced fluorescence allowed to perform precision frequency measurements of an Ar+ transition in collinear and anticollinear geometries simultaneously; then an exact relativistic formula for the absolute transition frequency V0= √VcVa was used. In this geometry the influence of ion source instabilities due to pressure and anode voltage fluctuations was minimized. The result is v0 = 485,573,619.7(3) MHz, which corresponds to Δv/v = 6*10-10. This represents an improvement of two orders of magnitude over the previous NIST published value.

  7. Interaction of superintense laser pulses with relativistic ions.

    PubMed

    Chirilă, C C; Joachain, C J; Kylstra, N J; Potvliege, R M

    2004-12-10

    At high intensities, three-step recollision processes driven by low frequency laser pulses, such as high-order harmonic generation and high-order above-threshold ionization, are normally severely suppressed by the magnetic-field component of the laser field. It is shown that this suppression is not severe, even for ponderomotive energies well above 10 keV, for multicharged ions moving at a sufficiently high relativistic velocity against a counterpropagating infrared laser pulse. Numerical results are presented for high-order harmonic emission by a single Ne9+ ion moving with a Lorentz factor gamma=15 against a Nd:glass laser beam. The calculations are done within a Coulomb-corrected nondipole strong field approximation. The approximation is tested by comparing with accurate results. PMID:15697809

  8. Interaction of Superintense Laser Pulses with Relativistic Ions

    NASA Astrophysics Data System (ADS)

    Chirilă, C. C.; Joachain, C. J.; Kylstra, N. J.; Potvliege, R. M.

    2004-12-01

    At high intensities, three-step recollision processes driven by low frequency laser pulses, such as high-order harmonic generation and high-order above-threshold ionization, are normally severely suppressed by the magnetic-field component of the laser field. It is shown that this suppression is not severe, even for ponderomotive energies well above 10keV, for multicharged ions moving at a sufficiently high relativistic velocity against a counterpropagating infrared laser pulse. Numerical results are presented for high-order harmonic emission by a single Ne9+ ion moving with a Lorentz factor γ=15 against a Nd:glass laser beam. The calculations are done within a Coulomb-corrected nondipole strong field approximation. The approximation is tested by comparing with accurate results.

  9. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source.

    PubMed

    Kondo, K; Yamamoto, T; Sekine, M; Okamura, M

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline. PMID:22380298

  10. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion sourcea)

    NASA Astrophysics Data System (ADS)

    Kondo, K.; Yamamoto, T.; Sekine, M.; Okamura, M.

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (˜100 μA) with high charge (˜10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  11. Ar-ion-laser-pumped infrared dye laser at 875-1084 nm

    SciTech Connect

    Kato, K.

    1984-12-01

    High-efficiency high-power cw dye-laser operation has been acheived from 875 to 1084 nm by pumping two styryl derivatives with an Ar-ion laser. Peak output powers as high as 900 and 750 mW were obtained around 925 and 980 nm, respectively.

  12. Laser Cooled Strontium Source for an Ion Interferometer

    NASA Astrophysics Data System (ADS)

    Lyon, Mary; Archibald, James; Erickson, Christopher; Durfee, Dallin

    2010-10-01

    We present a Strontium-87 magneto-optical trap (MOT) in a Low-Velocity-Intense-Source (LVIS) as the source of cooled, collimated atoms for an ion interferometer. Laser cooling and trapping is accomplished with a 461 nm frequency doubled laser and a pair of permanent magnets. A beam of cooled atoms is produced by passing the atoms through a hole drilled in one of the retroreflecting optics. The atoms are then photo-ionized in a two photon process.

  13. Laser-ion acceleration through controlled surface contamination

    SciTech Connect

    Hou Bixue; Nees, John A.; He Zhaohan; Easter, James H.; Thomas, Alexander G. R.; Krushelnick, Karl M.; Petrov, George; Davis, Jack

    2011-04-15

    In laser-plasma ion accelerators, control of target contamination layers can lead to selection of accelerated ion species and enhancement of acceleration. To demonstrate this, deuterons up to 75 keV are accelerated from an intense laser interaction with a glass target simply by placing 1 ml of heavy water inside the experimental chamber prior to pumping to generate a deuterated contamination layer on the target. Using the same technique with a deuterated-polystyrene-coated target also enhances deuteron yield by a factor of 3 to 5, while increasing the maximum energy of the generated deuterons to 140 keV.

  14. Simultaneous and sensitive analysis of aliphatic carboxylic acids by ion-chromatography using on-line complexation with copper(II) ion.

    PubMed

    Kemmei, Tomoko; Kodama, Shuji; Yamamoto, Atsushi; Inoue, Yoshinori; Hayakawa, Kazuichi

    2015-01-01

    A new approach to ion chromatography is proposed to improve the UV detection of aliphatic carboxylic acids separated by anion-exchange chromatography. When copper(II) ion added to the mobile phase, it forms complexes with carboxylic acids that can be detected at 240 nm. The absorbance was found to increase with increasing copper(II) ion concentration. The retention times of α-hydroxy acids were also found to depend on the copper(II) ion concentration. Addition of acetonitrile to the mobile phase improved the separation of aliphatic carboxylic acids. The detection limits of the examined carboxylic acids (formate, glycolate, acetate, lactate, propionate, 3-hydroxypropionate, n-butyrate, isobutyrate, n-valerate, isovalerate, n-caproate) calculated at S/N=3 ranged from 0.06 to 3 μM. The detector signal was linear over three orders of magnitude of carboxylic acid concentration. The proposed method was successfully applied to analyze aliphatic carboxylic acids in rainwater and bread. PMID:25523885

  15. The beat in laser-accelerated ion beams

    SciTech Connect

    Schnürer, M.; Abicht, F.; Bränzel, J.; Koschitzki, Ch.; Andreev, A. A.; Platonov, K. Yu.; Priebe, G.; Sandner, W.

    2013-10-15

    Regular modulation in the ion velocity distribution becomes detectable if intense femtosecond laser pulses with very high temporal contrast are used for target normal sheath acceleration of ions. Analytical and numerical analysis of the experimental observation associates the modulation with the half-cycle of the driving laser field period. In processes like ion acceleration, the collective and laser-frequency determined electron dynamics creates strong fields in plasma to accelerate the ions. Even the oscillatory motion of electrons and its influence on the acceleration field can dominate over smoothing effects in plasma if a high temporal contrast of the driving laser pulse is given. Acceleration parameters can be directly concluded out of the experimentally observed modulation period in ion velocity spectra. The appearance of the phenomenon at a temporal contrast of ten orders between the intensity of the pulse peak and the spontaneous amplified emission background as well as remaining intensity wings at picosecond time-scale might trigger further parameter studies with even higher contrast.

  16. Laser ion acceleration from mass-limited targets with preplasma

    NASA Astrophysics Data System (ADS)

    Lezhnin, K. V.; Kamenets, F. F.; Esirkepov, T. Zh.; Bulanov, S. V.; Klimo, O.; Weber, S.; Korn, G.

    2016-05-01

    The interaction of high intensity laser radiation with mass-limited target exhibits significant enhancement of the ion acceleration when the target is surrounded by an underdense plasma corona, as seen in numerical simulations. The self-generated quasistatic magnetic field squeezes the corona causing the intensification of a subsequent Coulomb explosion of the target. The electric field intensification at the target edges and plasma resonance effects results in the generation of characteristic density holes and further contributes to the ion acceleration.

  17. On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom

    SciTech Connect

    Esch, Ann van; Clermont, Christian; Devillers, Magali; Iori, Mauro; Huyskens, Dominique P.

    2007-10-15

    For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is proposed using a 2D ion chamber array (Seven29, PTW, Freiburg, Germany) inserted in a dedicated octagonal phantom, called Octavius. The octagonal shape allows easy positioning for measurements in multiple planes. The directional dependence of the response of the detector was primarily investigated on a dual energy (6 and 18 MV) Clinac 21EX (Varian Medical Systems, Palo Alto, CA) as no fixed angle incidences can be calculated in the Hi-Art TPS of TomoTherapy. The array was irradiated from different gantry angles and with different arc deliveries, and the dose distributions at the level of the detector were calculated with the AAA (Analytical Anisotropic Algorithm) photon dose calculation algorithm implemented in Eclipse (Varian). For validation on the 6 MV TomoTherapy unit, rotational treatments were generated, and dose distributions were calculated with the Hi-Art TPS. Multiple cylindrical ion chamber measurements were used to cross-check the dose calculation and dose delivery in Octavius in the absence of the 2D array. To compensate for the directional dependence of the 2D array, additional prototypes of Octavius were manufactured with built-in cylindrically symmetric compensation cavities. When using the Octavius phantom with a 2 cm compensation cavity, measurements with an accuracy comparable to that of single ion chambers can be achieved. The complete Octavius solution for quality assurance of rotational treatments consists of: The 2D array, two octagonal phantoms (with and without compensation layer), an insert for nine cylindrical ion chambers, and a set of inserts of

  18. On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom.

    PubMed

    Van Esch, Ann; Clermont, Christian; Devillers, Magali; Iori, Mauro; Huyskens, Dominique P

    2007-10-01

    For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is proposed using a 2D ion chamber array (Seven29, PTW, Freiburg, Germany) inserted in a dedicated octagonal phantom, called Octavius. The octagonal shape allows easy positioning for measurements in multiple planes. The directional dependence of the response of the detector was primarily investigated on a dual energy (6 and 18 MV) Clinac 21EX (Varian Medical Systems, Palo Alto, CA) as no fixed angle incidences can be calculated in the Hi-Art TPS of TomoTherapy. The array was irradiated from different gantry angles and with different arc deliveries, and the dose distributions at the level of the detector were calculated with the AAA (Analytical Anisotropic Algorithm) photon dose calculation algorithm implemented in Eclipse (Varian). For validation on the 6 MV TomoTherapy unit, rotational treatments were generated, and dose distributions were calculated with the Hi-Art TPS. Multiple cylindrical ion chamber measurements were used to cross-check the dose calculation and dose delivery in Octavius in the absence of the 2D array. To compensate for the directional dependence of the 2D array, additional prototypes of Octavius were manufactured with built-in cylindrically symmetric compensation cavities. When using the Octavius phantom with a 2 cm compensation cavity, measurements with an accuracy comparable to that of single ion chambers can be achieved. The complete Octavius solution for quality assurance of rotational treatments consists of: The 2D array, two octagonal phantoms (with and without compensation layer), an insert for nine cylindrical ion chambers, and a set of inserts of

  19. High intensity, argon ion laser-jet photochemistry

    NASA Astrophysics Data System (ADS)

    Wilson, R. Marshall; Schnapp, Karlyn A.; Hannemann, Klaus; Ho, Douglas M.; Memarian, Hamid R.; Azadnia, Ardeshir; Pinhas, Allan R.; Figley, Timothy M.

    A new technique for the study of high intensity solution photochemistry has been developed. With this laser-jet technique, a high velocity microjet is irradiated with the focussed output of an argon ion laser. Under these extremely high intensity conditions, photochemically generated transient species with suitable absorption properties are excited further and produce relatively large amounts of photoproducts which are not observed under low intensity conditions. The application of this laser-jet technique in the study of the photochemistry of radicals, biradicals, photoenols and the higher excited states of carbonyl and polycyclic aromatic compounds is described.

  20. Application of G criterion in metal vapor ion laser

    NASA Astrophysics Data System (ADS)

    Gang, Chen; Bailiang, Pan; Yi, Jin; Kun, Chen; Zhixin, Yao

    2003-09-01

    Application of G criterion to efficient operation of pulsed discharge-excited R-M transition metal vapor laser was successfully extended to univalent ionic lasing medium from neutral atomic lasing medium on the basis of analyzing the simulation results of 1.09 μm Sr + lasing process. All of the known 17 R-M transition laser lines of univalent ions follow the G criterion except one, to which an interpretation is given. Furthermore, we suggest that only 69 lines among 212 possible R-M transition laser lines predicted by S.V. Markova, which satisfy the G criterion, should be explored first.

  1. Ion formation in laser-irradiated cesium vapor

    NASA Astrophysics Data System (ADS)

    Mahmoud, M. A.; Gamal, Y. E. E.; Abd El-Rahman, H. A.

    2006-11-01

    We study theoretically the formation of Cs and Cs2+ during cw laser radiation resonant with 6s-7p transition of Cs atomic vapor. This is done by numerically solving rate equations for the evolution of atomic state and electron populations. The results of calculations for the atomic and molecular ions density at different values of laser power clarified that the associative ionization and Penning ionization process play an important role for producing the Cs2+ and Cs, respectively, during the plasma formation. Also, the results showed that laser power of the order of 150 mW and 40 50 ns irradiation time are optimal in producing a fully ionized plasma.

  2. Optimum laser intensity for the production of energetic deuterium ions from laser-cluster interaction

    NASA Astrophysics Data System (ADS)

    Bang, W.; Dyer, G.; Quevedo, H. J.; Bernstein, A. C.; Gaul, E.; Rougk, J.; Aymond, F.; Donovan, M. E.; Ditmire, T.

    2013-09-01

    We measured, using Petawatt-level pulses, the average ion energy and neutron yield in high-intensity laser interactions with molecular clusters as a function of laser intensity. The interaction volume over which fusion occurred (1-10 mm3) was larger than previous investigations, owing to the high laser power. Possible effects of prepulses were examined by implementing a pair of plasma mirrors. Our results show an optimum laser intensity for the production of energetic deuterium ions both with and without the use of the plasma mirrors. We measured deuterium plasmas with 14 keV average ion energies, which produced 7.2 × 106 and 1.6 × 107 neutrons in a single shot with and without plasma mirrors, respectively. The measured neutron yields qualitatively matched the expected yields calculated using a cylindrical plasma model.

  3. Optimum laser intensity for the production of energetic deuterium ions from laser-cluster interaction

    SciTech Connect

    Bang, W.; Dyer, G.; Quevedo, H. J.; Bernstein, A. C.; Gaul, E.; Rougk, J.; Aymond, F.; Donovan, M. E.; Ditmire, T.

    2013-09-15

    We measured, using Petawatt-level pulses, the average ion energy and neutron yield in high-intensity laser interactions with molecular clusters as a function of laser intensity. The interaction volume over which fusion occurred (1–10 mm{sup 3}) was larger than previous investigations, owing to the high laser power. Possible effects of prepulses were examined by implementing a pair of plasma mirrors. Our results show an optimum laser intensity for the production of energetic deuterium ions both with and without the use of the plasma mirrors. We measured deuterium plasmas with 14 keV average ion energies, which produced 7.2 × 10{sup 6} and 1.6 × 10{sup 7} neutrons in a single shot with and without plasma mirrors, respectively. The measured neutron yields qualitatively matched the expected yields calculated using a cylindrical plasma model.

  4. Rare earth ion doped non linear laser crystals

    NASA Astrophysics Data System (ADS)

    Jaque, D.; Romero, J. J.; Ramirez, M. O.; Garcia, J. A. S.; de Las Heras, C.; Bausa, L. E.; Sole, J. G.

    2003-01-01

    We show how non linear crystals activated with Yb3+ or Nd3+ ions can be used to develop diode pumped solid state lasers emitting in the visible region of the electromagnetic spectrum. For this purpose we have selected relevant examples of systems investigated in our laboratory.

  5. Identification of organic hydroperoxides and hydroperoxy acids in secondary organic aerosol formed during the ozonolysis of different monoterpenes and sesquiterpenes by on-line analysis using atmospheric pressure chemical ionization ion trap mass spectrometry.

    PubMed

    Reinnig, Marc-Christopher; Warnke, Jörg; Hoffmann, Thorsten

    2009-06-01

    On-line ion trap mass spectrometry (ITMS) enables the real-time characterization of reaction products of secondary organic aerosol (SOA). The analysis was conducted by directly introducing the aerosol particles into the ion source. Positive-ion chemical ionization at atmospheric pressure (APCI(+)) ITMS was used for the characterization of constituents of biogenic SOA produced in reaction-chamber experiments. APCI in the positive-ion mode usually enables the detection of [M+H](+) ions of the individual SOA components. In this paper the identification of organic peroxides from biogenic volatile organic compounds (VOCs) by on-line APCI-ITMS is presented. Organic peroxides containing a hydroperoxy group, generated by gas-phase ozonolysis of monoterpenes (alpha-pinene and beta-pinene) and sesquiterpenes (alpha-cedrene and alpha-copaene), could be detected via on-line APCI(+)-MS/MS experiments. A characteristic neutral loss of 34 Da (hydrogen peroxide, H(2)O(2)) in the on-line MS/MS spectra is a clear indication for the existence of an organic peroxide, containing a hydroperoxy functional group. PMID:19412924

  6. Preliminary result of rapid solenoid for controlling heavy-ion beam parameters of laser ion source

    DOE PAGESBeta

    Okamura, M.; Sekine, M.; Ikeda, S.; Kanesue, T.; Kumaki, M.; Fuwa, Y.

    2015-03-13

    To realize a heavy ion inertial fusion driver, we have studied a possibility of laser ion source (LIS). A LIS can provide high current high brightness heavy ion beams, however it was difficult to manipulate the beam parameters. To overcome the issue, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The rapid ramping magnetic field could enhance limited time slice of the current and simultaneously the beam emittance changed accordingly. This approach may also useful to realize an ion source for HIF power plant.

  7. Separation and quantification of 238U, 232Th and rare earths in monazite samples by ion chromatography coupled with on-line flow scintillation detector.

    PubMed

    Borai, E H; Mady, A S

    2002-10-01

    An alternative procedure has been described for efficient separation and quantitative determination of uranium (U), thorium (Th) and rare earth elements (REEs) in monazite mineral by high performance ion chromatographic system (IC). Different variables affecting the distribution coefficient, the retention and hence separation efficiency such as eluent flow rate and concentrations of HCI and ammonium sulfate (NH4)2SO4 containing the mobile phase were studied. The developed separation protocol of U, Th and REEs was optimized using an Ion Pac CS5 separation column followed by post-column derivatization reaction with Arsenaso III and UV-VIS spectrophotometric detection. Comparative evaluation of U, Th and REEs concentration in monazite mineral was demonstrated using two different on-line detection modes including flow through cell scintillation detector (FSD) and UV-VIS spectrophotometer. Response of the FSD was found to be linear over the full range of activities investigated (4-100 Bq). The lower limits of detection (LLD) for the investigated radionuclides were 3.0+0.1 Bq for 238U and 6.0 +/- 0.1 Bq for 232Th. The detection of 238U and 232Th by FSD shows good agreement with the corresponding determination by UV-VIS spectrophotometer. The content of ThO2 and U3O8 in monazite sample were found to be 4.7 +/- 0.1% and 0.42 +/- 0.04% using UV-VIS detector and 4.3 +/- 0.1% and 0.45 +/- 0.1% using FSD, respectively. PMID:12361323

  8. Improved ion acceleration via laser surface plasma waves excitation

    SciTech Connect

    Bigongiari, A.

    2013-05-15

    The possibility of enhancing the emission of the ions accelerated in the interaction of a high intensity ultra-short (<100 fs) laser pulse with a thin target (<10λ{sub 0}), via surface plasma wave excitation is investigated. Two-dimensional particle-in-cell simulations are performed for laser intensities ranging from 10{sup 19} to 10{sup 20} Wcm{sup −2}μm{sup 2}. The surface wave is resonantly excited by the laser via the coupling with a modulation at the target surface. In the cases where the surface wave is excited, we find an enhancement of the maximum ion energy of a factor ∼2 compared to the cases where the target surface is flat.

  9. Enabling Nanotechnology with Focused Ion Beams from Laser Cooled Atoms

    NASA Astrophysics Data System (ADS)

    Steele, A. V.; Knuffman, B.; Orloff, J.; Maazouz, M.; McClelland, J. J.

    2011-05-01

    The Magneto-Optical Trap Ion Source (MOTIS) being developed at NIST has the potential to enable numerous advances in nanoscale science. In a MOTIS, atoms are captured into a MOT, photoionized, and accelerated to an energy of a few hundred eV to a few tens of kV. A beam formed in this way can be brought to a tight focus, competitive with the commercial focused ion beam machines deployed widely today. Additionally, the unique characteristics of this source, coupled with the user's choice of ion from the long and growing list of laser-coolable atomic species suggest that the MOTIS has the potential to advance the state of the art in applications such as imaging, nanofabrication, secondary ion mass spectrometry, and others. I will present high-resolution images from our lithium and chromium MOTIS-based focused ion beams and discuss applications which we will pursue with these new tools.

  10. Laser ion source for ITEP-TWAC project

    NASA Astrophysics Data System (ADS)

    Balabaev, A.; Kondrashev, S.; Sharkov, B.; Vasiliev, A.

    2005-10-01

    Laser ion source (LIS) is the only type of source capable of generating 10-30 mA beams of highly charged ions for the ITEP-TeraWatt (TWAC) accelerator/accumulator facility [B.Yu. Sharkov et al ., Nucl. Instrum. Methods Phys. Res. A 415 20 (1998).]. The assembling stage of the new LIS based on 100 J/1 Hz master oscillator-power amplifier CO2-laser system [Yu. Satov, et al ., J. Russ. Laser Res. 25(3) 205 (2004).] is in progress at ITEP now. In the first phase, the ion beam parameters (charge state distribution, current, pulse length and emittance) will be specified for different elements and target irradiation conditions. According to the planning, the new LIS and the new high-current injector [D. Kashinsky, et al ., Proceedings of the Heavy Ion Fusion Conference, Moskow (2002).] will be used to deliver the beams of highly charged ions for the ITEP-TWAC accelerator/accumulator facility.

  11. Selective deuterium ion acceleration using the Vulcan petawatt laser

    SciTech Connect

    Krygier, A. G.; Morrison, J. T.; Kar, S. Ahmed, H.; Alejo, A.; Green, A.; Jung, D.; Clarke, R.; Notley, M.; Fuchs, J.; Vassura, L.; Kleinschmidt, A.; Roth, M.; Najmudin, Z.; Nakamura, H.; Norreys, P.; Oliver, M.; Zepf, M.; Borghesi, M.; Freeman, R. R.

    2015-05-15

    We report on the successful demonstration of selective acceleration of deuterium ions by target-normal sheath acceleration (TNSA) with a high-energy petawatt laser. TNSA typically produces a multi-species ion beam that originates from the intrinsic hydrocarbon and water vapor contaminants on the target surface. Using the method first developed by Morrison et al. [Phys. Plasmas 19, 030707 (2012)], an ion beam with >99% deuterium ions and peak energy 14 MeV/nucleon is produced with a 200 J, 700 fs, >10{sup 20}W/cm{sup 2} laser pulse by cryogenically freezing heavy water (D{sub 2}O) vapor onto the rear surface of the target prior to the shot. Within the range of our detectors (0°–8.5°), we find laser-to-deuterium-ion energy conversion efficiency of 4.3% above 0.7 MeV/nucleon while a conservative estimate of the total beam gives a conversion efficiency of 9.4%.

  12. Laser Acceleration of Ultrashort Ion Bunches and Femtosecond Neutron Sources

    SciTech Connect

    Macchi, A.; Cattani, F.; Liseykina, T. V.; Cornolti, F.

    2006-04-07

    We have theoretically investigated the acceleration of ions in the interaction of high intensity, circularly polarized laser pulses with overdense plasmas. By using 1D and 2D particle-in-cell (PIC) simulations we find that high-density, short duration ion bunches moving into the plasma are promptly generated at the laser-plasma interaction surface. This regime is qualitatively different from ion acceleration regimes driven by fast electrons, such as sheath acceleration at the back of the target or shock acceleration at the front, which occur for linear polarization. A simple analytical model accounts for the numerical observations and provides scaling laws for the ion bunch velocity and generation time as a function of pulse intensity and plasma density. The present mechanism based on circular polarization of the laser pulse leads to moderate ion energies (in the 100 keV-1 MeV range) but very high ion densities and low beam divergence. These ion bunches might be of interest for problems of compression and acceleration of high-density matter by short pulses as well as for the development of compact neutron sources. We analyzed a scheme based on two-side irradiation of a thin foil deuterated target, where two colliding ion bunches are produced leading to an ultrashort neutron burst. We evaluated that, for intensities of a few 1019 W cm-2, more than 103 neutrons per Joule may be produced within a time shorter than one femtosecond. Another scheme based on a layered deuterium-tritium target is outlined.

  13. Targets on superhydrophobic surfaces for laser ablation ion sources

    NASA Astrophysics Data System (ADS)

    Renisch, D.; Beyer, T.; Blaum, K.; Block, M.; Düllmann, Ch. E.; Eberhardt, K.; Eibach, M.; Nagy, Sz.; Neidherr, D.; Nörtershäuser, W.; Smorra, C.

    2012-06-01

    Target preparation techniques for a laser ablation ion source at the Penning-trap mass spectrometer TRIGA-TRAP have been investigated with regard to future experiments with actinides. To be able to perform mass measurements on these nuclides considering their limited availability, an efficient target preparation technique is mandatory. Here, we report on a new approach for target production using backings, which are pretreated in a way that a superhydrophobic surface is formed. This resulted in improved targets with a more homogeneous distribution of the target material compared to standard techniques with unmodified backings. It was demonstrated that the use of these new targets in a laser ablation ion source improved the ion production significantly.

  14. Pulsed hollow-cathode ion lasers: pumping and lasing parameters

    SciTech Connect

    Zinchenko, S P; Ivanov, I G

    2012-06-30

    Optimal discharge conditions have been experimentally found for ion lasers excited in the hollow-cathode discharge plasma by microsecond current pulses by pumping working atoms in secondkind collisions with ions and metastable buffer-gas atoms. Measurements of the output power of krypton ion and zinc-, cadmium-, mercury-, thallium-, copper-, and gallium-vapour lasers in tubes with cathodes of different diameters showed that the pulse power reaches several tens of watts, and the average power obtained with cathodes 2 cm in diameter and a length of 40 cm or more approaches 1 W. Lasing in most media is observed simultaneously at several lines (the multi-wavelength regime). Lasing on a three-component (He - Kr - Hg) mixture is realised in the multi-wavelength regime at blue, red, and IR lines.

  15. Electric-discharge-pumped nitrogen ion laser

    NASA Technical Reports Server (NTRS)

    Laudenslager, J. B.; Pacala, T. J.; Wittig, C.

    1976-01-01

    The routine operation is described of an N2(+) laser oscillating on the first negative band system of N2(+) which is produced in a preionized transverse discharge device. The discharge design incorporates features which favor the efficient production of the excitation transfer reaction of He2(+) with N2. A capacitive discharge switched by means of a high-current grounded grid thyratron is used to meet the design requirement of a volumetric discharge in high-pressure gas mixtures where the electric discharge need not have an ultrafast rise time (greater than 10 nsec) but should be capable of transferring large quantities of stored electric energy to the gas. A peak power of 180 kW in an 8-nsec laser pulse was obtained with a 0.1% mixture of N2 in helium at a total pressure of 3 atm. The most intense laser oscillations were observed on the (0,1) vibrational transition at 427.8 microns.

  16. GeV Laser Ion Acceleration from Ultrathin Targets: The Laser Break-Out Afterburner

    NASA Astrophysics Data System (ADS)

    Yin, Lin

    2006-10-01

    A new laser-driven ion acceleration mechanism has been identified using particle-in-cell simulations. After a brief period of target normal sheath acceleration (TNSA) [S. P. Hatchett, et al., Phys. Plasmas, 7, 2076 (2000)], two distinct stages follow: first, a period of enhanced TNSA during which the cold electron background converts entirely to hot electrons, and second, the ``laser break-out afterburner'' (BOA) when the laser penetrates to the rear of the target and generates a large longitudinal electric field localized at the rear of the target with the location of the peak field co-moving with the ions. This mechanism allows ion acceleration to GeV energies at vastly reduced laser intensities compared with earlier acceleration schemes. The new mechanism enables the acceleration of carbon ions to greater than 2 GeV energy at a laser intensity of only 10^21 W/cm^2, an intensity that has been realized in existing laser systems. Other techniques for achieving these energies in the literature [D. Habs et al., Progress in Particle and Nuclear Physics, 46, 375 (2001); T. Esirkepov et al., Phys. Rev. Lett. 92, 175003-1 (2004)] rely upon intensities of 10^24 W/cm^2 or above, i.e., 2-3 orders of magnitude higher than any laser intensity that has been demonstrated to date. Also, the BOA mechanism attains higher energy and efficiency than TNSA where the scaling laws [Hegelich et al., Phys. Plasmas, 12, 056314 (2005)] predict carbon energies of 50 MeV/u for identical laser conditions. In the early stages of the BOA, the carbon ions accelerate as a quasi-monoenergetic bunch with median energy higher than that realized recently experimentally [Hegelich et al., Nature, 441, 439 (2006)].

  17. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited).

    PubMed

    Zhao, H Y; Zhang, J J; Jin, Q Y; Liu, W; Wang, G C; Sun, L T; Zhang, X Z; Zhao, H W

    2016-02-01

    A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 10(13) W cm(-2) in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications. PMID:26931978

  18. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited)

    NASA Astrophysics Data System (ADS)

    Zhao, H. Y.; Zhang, J. J.; Jin, Q. Y.; Liu, W.; Wang, G. C.; Sun, L. T.; Zhang, X. Z.; Zhao, H. W.

    2016-02-01

    A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 1013 W cm-2 in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.

  19. Amplitude Noise Reduction of Ion Lasers with Optical Feedback

    NASA Technical Reports Server (NTRS)

    Herring, Gregory C.

    2011-01-01

    A reduction in amplitude noise on the output of a multi-mode continuous-wave Ar-ion laser was previously demonstrated when a fraction of the output power was retroreflected back into the laser cavity. This result was reproduced in the present work and a Fabry-Perot etalon was used to monitor the longitudinal mode structure of the laser. A decrease in the number of operating longitudinal cavity modes was observed simultaneously with the introduction of the optical feedback and the onset of the amplitude noise reduction. The noise reduction is a result of a reduced number of lasing modes, resulting in less mode beating and amplitude fluctuations of the laser output power.

  20. Optimizing direct intense-field laser acceleration of ions

    SciTech Connect

    Harman, Zoltan; Salamin, Yousef I.; Galow, Benjamin J.; Keitel, Christoph H.

    2011-11-15

    The dynamics of ion acceleration in tightly focused laser beams is investigated in relativistic simulations. Studies are performed to find the optimal parameters which maximize the energy gain, beam quality, and flux. The exit ionic kinetic energy and its uncertainty are improved and the number of accelerated particles is increased by orders of magnitude over our earlier results, especially when working with a longer laser wavelength. Laser beams of powers of 0.1-10 petawatts and focused to subwavelength spot radii are shown to directly accelerate protons and bare nuclei of helium, carbon, and oxygen from a few to several hundred MeV/nucleon. Variation of the volume of the initial ionic ensemble, as well as the introduction of a pulse shape on the laser fields, have been investigated and are shown to influence the exit particle kinetic energies only slightly.

  1. Proposal for laser cooling of rare-earth ions

    NASA Astrophysics Data System (ADS)

    Lepers, Maxence; Hong, Ye; Wyart, Jean-François; Dulieu, Olivier

    2016-01-01

    The efficiency of laser cooling relies on the existence of an almost closed optical-transition cycle in the energy spectrum of the considered species. In this respect, rare-earth elements exhibit many transitions which are likely to induce noticeable leaks from the cooling cycle. In this work, to determine whether laser cooling of singly ionized erbium Er+ is feasible, we have performed accurate electronic-structure calculations of energies and spontaneous-emission Einstein coefficients of Er+, using a combination of ab initio and least-squares-fitting techniques. We identify five weak closed transitions suitable for laser cooling, the broadest of which is in the kilohertz range. For the strongest transitions, by simulating the cascade dynamics of spontaneous emission, we show that repumping is necessary, and we discuss possible repumping schemes. We expect our detailed study on Er+ to give good insight into the laser cooling of neighboring ions such as Dy+.

  2. Fragmentation of negative ions in a strong laser field

    NASA Astrophysics Data System (ADS)

    Berry, Ben; Jochim, Bethany; Severt, T.; Feizollah, Peyman; Rajput, Jyoti; Hayes, D.; Carnes, K. D.; Esry, B. D.; Ben-Itzhak, I.

    2016-05-01

    The fragmentation of negative ions in a strong laser field can provide a testing ground for a variety of unique phenomena. For example, anions with a loosely bound electron allow for the study of rescattering phenomena at lower laser intensities than for neutral targets. We study the behavior of keV anion beams in an ultrafast, intense laser field. The use of a fast-beam target facilitates the measurement of neutral fragments. This capability allows us to explore laser-induced dynamics in both ionic and neutral charge states. Using a coincidence 3D momentum imaging technique, we obtain the full 3D momentum of all nuclear fragments. In this preliminary work, we study atomic (H-) and molecular (H2-,F2-)systems with the goal of identifying and controlling their fragmentation pathways. This work was supported by the Chemical Sciences, Geosciences, and Biosciences Division, Office of Basic Energy Sciences, Office of Science, U.S. Department of Energy.

  3. Ion trap mass spectrometric detection of laser desorbed ions from derivatized fused silica fibers

    SciTech Connect

    Garrett, A.W.; Earl, W.L.; Cisper, M.E.; Nogar, N.S.; Hemberger, P.H.

    1994-12-31

    Solid-phase microextraction of analytes from complex matrices using fused silica fibers has many advantages over traditional chemical sample preparation technique. Microextraction requires small sample sizes little sample preparation (providing rapid sample turnaround time), and greatly reduces the amount of chemical waste generated in sample preparation. These advantages make fused silica fibers attractive for direct sampling and detection experiments using laser desorption ion trap mass spectrometry (LITMS). The drawback is the very small area ({approximately}1 mm{sup 2}) exposed to laser irradiation, which limits the amount of material desorbed into the ion trap.

  4. Negative ion beam generation in laser plasma interactions

    NASA Astrophysics Data System (ADS)

    Jequier, Sophie; Tikhonchuk, Vladimir; Ter-Avetisyan, Sargis

    2013-10-01

    Detection of a large number of energetic negative ions and neutral atoms have been reported in recent intense laser plasma interaction experiments. These particles were produced from fast positive ions (proton, carbon, oxygen) accelerated from a laser produced plasma when they were passing through a cold spray of water or ethanol. The negative ions formation is strongly related to the fast positive ions, and it is explained by a process of a single electron capture - loss. Double charge exchange, elastic scattering and energy loss phenomena have been neglected since their cross sections are much smaller. Assuming independent atoms approximation, we study populations evolution through the interaction zone analytically and numerically by solving the rate equations using cross sections drawn from literature. Taking into account the energy distribution of the incident ions, the calculations give the final energy distribution for the different species that can be compared to experimental spectra. First results obtained for hydrogen in the water case indicate that this model can explain the main observed features. The results concerning the carbon and oxygen ions will be also presented as well as refinement of the cross sections since some cross sections are missing for these energies.

  5. Laser cooling of a stored ion beam: A first step towards crystalline beams

    SciTech Connect

    Hangst, J.S.

    1992-09-01

    This report discusses: a brief introduction to storage rings; crystalline beams; laser cooling of ion beams; description of astrid-the experimental setup; first experiments with lithium 7 ion beam; experiments with erbium 166 ion beams; further experiments with lithium 7 ion beams; beam dynamics, laser cooling,and crystalline beams in astrid; possibilities for further study in astrid.

  6. Ion-pairing liquid chromatography with on-line electrospray ion trap mass spectrometry for the structural analysis of N-unsubstituted heparin/heparan sulfate.

    PubMed

    Du, Jia Yan; Chen, Lan Rong; Liu, Su; Lin, Jiang Hui; Liang, Qun Tao; Lyon, Malcolm; Wei, Zheng

    2016-08-15

    The rare N-unsubstituted glucosamine (GlcNH3(+)) residues in heparan sulfate (HS) have important biological and pathophysiological roles. In this study, a high-resolution method for the separation and analysis of N-unsubstituted disaccharides of heparin/HS is described. Four N-unsubstituted disaccharides, together with eight N-substituted species, can be well-separated by ion-pair reverse-phase ultra-performance liquid chromatography. Each disaccharide can then be detected and its relative abundance quantified using electrospray ionization mass spectrometry in the negative mode. Because of its high sensitivity, without interference from proteins and other sample impurities, this method is particularly useful in the analysis of low content GlcNH3(+) residues in small amounts of biological materials, eg. sera, tissue and cell culture-derived samples. This would lead to a better understanding of the biological origin of GlcNH3(+) residues and their increasingly important function in human health and disease. PMID:27322632

  7. LIGHT - from laser ion acceleration to future applications

    NASA Astrophysics Data System (ADS)

    Roth, Markus; Light Collaboration

    2013-10-01

    Creation of high intensity multi-MeV ion bunches by high power lasers became a reliable tool during the last 15 years. The laser plasma source provides for TV/m accelerating field gradients and initially sub-ps bunch lengths. However, the large envelope divergence and the continuous exponential energy spectrum are substential drawbacks for many possible applications. To face this problem, the LIGHT collaboration was founded (Laser Ion Generation, Handling and Transport). The collaboration consists of several university groups and research centers, namely TU Darmstadt, JWGU Frankfurt, HI Jena, HZDR Dresden and GSI Darmstadt. The central goal is building a test beamline for merging laser ion acceleration with conventional accelerator infrastructure at the GSI facility. In the latest experiments, low divergent proton bunches with a central energy of up to 10 MeV and containing >109 particles could be provided at up to 2.2 m behind the plasma source, using a pulsed solenoid. In a next step, a radiofrequency cavity will be added to the beamline for phase rotation of these bunches, giving access to sub-ns bunch lengths and reaching highest intensities. An overview of the LIGHT objectives and the recent experimental results will be given. This work was supported by HIC4FAIR.

  8. Ion-beam assisted laser fabrication of sensing plasmonic nanostructures

    NASA Astrophysics Data System (ADS)

    Kuchmizhak, Aleksandr; Gurbatov, Stanislav; Vitrik, Oleg; Kulchin, Yuri; Milichko, Valentin; Makarov, Sergey; Kudryashov, Sergey

    2016-01-01

    Simple high-performance, two-stage hybrid technique was developed for fabrication of different plasmonic nanostructures, including nanorods, nanorings, as well as more complex structures on glass substrates. In this technique, a thin noble-metal film on a dielectric substrate is irradiated by a single tightly focused nanosecond laser pulse and then the modified region is slowly polished by an accelerated argon ion (Ar+) beam. As a result, each nanosecond laser pulse locally modifies the initial metal film through initiation of fast melting and subsequent hydrodynamic processes, while the following Ar+-ion polishing removes the rest of the film, revealing the hidden topography features and fabricating separate plasmonic structures on the glass substrate. We demonstrate that the shape and lateral size of the resulting functional plasmonic nanostructures depend on the laser pulse energy and metal film thickness, while subsequent Ar+-ion polishing enables to vary height of the resulting nanostructures. Plasmonic properties of the fabricated nanostructures were characterized by dark-field micro-spectroscopy, Raman and photoluminescence measurements performed on single nanofeatures, as well as by supporting numerical calculations of the related electromagnetic near-fields and Purcell factors. The developed simple two-stage technique represents a new step towards direct large-scale laser-induced fabrication of highly ordered arrays of complex plasmonic nanostructures.

  9. Ion-beam assisted laser fabrication of sensing plasmonic nanostructures.

    PubMed

    Kuchmizhak, Aleksandr; Gurbatov, Stanislav; Vitrik, Oleg; Kulchin, Yuri; Milichko, Valentin; Makarov, Sergey; Kudryashov, Sergey

    2016-01-01

    Simple high-performance, two-stage hybrid technique was developed for fabrication of different plasmonic nanostructures, including nanorods, nanorings, as well as more complex structures on glass substrates. In this technique, a thin noble-metal film on a dielectric substrate is irradiated by a single tightly focused nanosecond laser pulse and then the modified region is slowly polished by an accelerated argon ion (Ar(+)) beam. As a result, each nanosecond laser pulse locally modifies the initial metal film through initiation of fast melting and subsequent hydrodynamic processes, while the following Ar(+)-ion polishing removes the rest of the film, revealing the hidden topography features and fabricating separate plasmonic structures on the glass substrate. We demonstrate that the shape and lateral size of the resulting functional plasmonic nanostructures depend on the laser pulse energy and metal film thickness, while subsequent Ar(+)-ion polishing enables to vary height of the resulting nanostructures. Plasmonic properties of the fabricated nanostructures were characterized by dark-field micro-spectroscopy, Raman and photoluminescence measurements performed on single nanofeatures, as well as by supporting numerical calculations of the related electromagnetic near-fields and Purcell factors. The developed simple two-stage technique represents a new step towards direct large-scale laser-induced fabrication of highly ordered arrays of complex plasmonic nanostructures. PMID:26776569

  10. Ion-beam assisted laser fabrication of sensing plasmonic nanostructures

    PubMed Central

    Kuchmizhak, Aleksandr; Gurbatov, Stanislav; Vitrik, Oleg; Kulchin, Yuri; Milichko, Valentin; Makarov, Sergey; Kudryashov, Sergey

    2016-01-01

    Simple high-performance, two-stage hybrid technique was developed for fabrication of different plasmonic nanostructures, including nanorods, nanorings, as well as more complex structures on glass substrates. In this technique, a thin noble-metal film on a dielectric substrate is irradiated by a single tightly focused nanosecond laser pulse and then the modified region is slowly polished by an accelerated argon ion (Ar+) beam. As a result, each nanosecond laser pulse locally modifies the initial metal film through initiation of fast melting and subsequent hydrodynamic processes, while the following Ar+-ion polishing removes the rest of the film, revealing the hidden topography features and fabricating separate plasmonic structures on the glass substrate. We demonstrate that the shape and lateral size of the resulting functional plasmonic nanostructures depend on the laser pulse energy and metal film thickness, while subsequent Ar+-ion polishing enables to vary height of the resulting nanostructures. Plasmonic properties of the fabricated nanostructures were characterized by dark-field micro-spectroscopy, Raman and photoluminescence measurements performed on single nanofeatures, as well as by supporting numerical calculations of the related electromagnetic near-fields and Purcell factors. The developed simple two-stage technique represents a new step towards direct large-scale laser-induced fabrication of highly ordered arrays of complex plasmonic nanostructures. PMID:26776569