Science.gov

Sample records for operational diagnostics methods

  1. Development of wide area environment accelerator operation and diagnostics method

    NASA Astrophysics Data System (ADS)

    Uchiyama, Akito; Furukawa, Kazuro

    2015-08-01

    Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  2. Assessment of diagnostic methods for solenoid-operated valves

    NASA Astrophysics Data System (ADS)

    Kryter, R. C.; Farmer, W. S.

    Solenoid-operated valves (SOV's) were studied at Oak Ridge National Laboratory as part of the USNRC Nuclear Plant Aging Research (NPAR) Program. The primary objective of the study was to identify, evaluate, and recommend methods for inspection, surveillance, monitoring, and maintenance of SOV's that can help ensure their operational readiness - that is, their ability to perform required safety functions under all anticipated operating conditions, since failure of one of these small and relatively inexpensive devices could have serious consequences under certain circumstances. Intrusive techniques requiring the addition of magnetic or acoustic sensors or the application of special test signals were investigated briefly, but major emphasis was placed on the examination of condition-indicating techniques that can be applied with minimal cost and impact on plant operation. These include monitoring coil mean temperature remotely by means of coil dc resistance or ac impedance, determining valve plunger position by means of coil ac impedance, verifying unrestricted SOV plunger movement by measuring current and voltage at their critical bistable (pull-in and drop-out) values, and detecting the presence of shorted turns or insulation breakdown within the solenoid coil using interrupted-current test methods. Experimental results are presented that demonstrate the technical feasibility and practicality of the monitoring techniques assessed in the study, and recommendations for further work are provided.

  3. Using the Attribute Hierarchy Method to Make Diagnostic Inferences about Examinees' Knowledge and Skills in Mathematics: An Operational Implementation of Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Gierl, Mark J.; Alves, Cecilia; Majeau, Renate Taylor

    2010-01-01

    The purpose of this study is to apply the attribute hierarchy method in an operational diagnostic mathematics program at Grades 3 and 6 to promote cognitive inferences about students' problem-solving skills. The attribute hierarchy method is a psychometric procedure for classifying examinees' test item responses into a set of structured attribute…

  4. First Wall and Operational Diagnostics

    SciTech Connect

    Lasnier, C; Allen, S; Boedo, J; Groth, M; Brooks, N; McLean, A; LaBombard, B; Sharpe, J; Skinner, C; Whyte, D; Rudakov, D; West, W; Wong, C

    2006-06-19

    In this chapter we review numerous diagnostics capable of measurements at or near the first wall, many of which contribute information useful for safe operation of a tokamak. There are sections discussing infrared cameras, visible and VUV cameras, pressure gauges and RGAs, Langmuir probes, thermocouples, and erosion and deposition measurements by insertable probes and quartz microbalance. Also discussed are dust measurements by electrostatic detectors, laser scattering, visible and IR cameras, and manual collection of samples after machine opening. In each case the diagnostic is discussed with a view toward application to a burning plasma machine such as ITER.

  5. Myasthenia Gravis: Tests and Diagnostic Methods

    MedlinePlus

    ... Affiliations Foundation Focus Newsletter E-Update Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events Spring 2016 ...

  6. A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2011-01-01

    Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

  7. Application of diagnostics to determine motor-operated valve operational readiness

    SciTech Connect

    Eissenberg, D.M.

    1986-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor curent signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment.

  8. Tomographic methods in flow diagnostics

    NASA Technical Reports Server (NTRS)

    Decker, Arthur J.

    1993-01-01

    This report presents a viewpoint of tomography that should be well adapted to currently available optical measurement technology as well as the needs of computational and experimental fluid dynamists. The goals in mind are to record data with the fastest optical array sensors; process the data with the fastest parallel processing technology available for small computers; and generate results for both experimental and theoretical data. An in-depth example treats interferometric data as it might be recorded in an aeronautics test facility, but the results are applicable whenever fluid properties are to be measured or applied from projections of those properties. The paper discusses both computed and neural net calibration tomography. The report also contains an overview of key definitions and computational methods, key references, computational problems such as ill-posedness, artifacts, missing data, and some possible and current research topics.

  9. [Syndrome of diabetic foot: modern diagnostic methods].

    PubMed

    Plekhanov, A N; Markevich, P S

    2014-01-01

    We summarize the literature data on diagnostics of diabetic foot syndrome including clinical examination and special invasive and non-invasive studies of the vascular system. The main methods are ultrasound dopplerography, X-ray contrast angiography, and ultrasound duplex scanning. Special attention is given to instrumental diagnostics of diabetic neuropathies. The golden standard for the evaluation of the function of the peripheral nervous system is electroneuromyography. Methods for the study of diabetic foot complications, such as osteoarthropathy and trophic ulcers, are discussed. PMID:25782303

  10. Trends in Laboratory Diagnostic Methods in Periodontology.

    PubMed

    Bolerázska, Beáta; Mareková, Mária; Markovská, Neda

    2016-01-01

    This work presents a summary of current knowledge on the laboratory diagnosis of periodontitis. It focuses on the theoretical foundations and is supplemented with new knowledge. It subsequently describes specifically the laboratory diagnosis methods of periodontitis: the protein expression of inflammation, oral microbiology and molecular diagnostics. Periodontitis is a serious disease worldwide and its confirmed association with systemic diseases means its severity is increasing. Its laboratory diagnosis has the potential to rise to the level of clinical and diagnostic imaging. The transfer of diagnostic methods from laboratory to clinical use is increasingly used in the prevention and monitoring of the exacerbation and treatment of periodontal disease, as well as of its impact on systemic disease. PMID:27131349

  11. LOCSET Phase Locking: Operation, Diagnostics, and Applications

    NASA Astrophysics Data System (ADS)

    Pulford, Benjamin N.

    The aim of this dissertation is to discuss the theoretical and experimental work recently done with the Locking of Optical Coherence via Single-detector Electronic-frequency Tagging (LOCSET) phase locking technique developed and employed here are AFRL. The primary objectives of this effort are to detail the fundamental operation of the LOCSET phase locking technique, recognize the conditions in which the LOCSET control electronics optimally operate, demonstrate LOCSET phase locking with higher channel counts than ever before, and extend the LOCSET technique to correct for low order, atmospherically induced, phase aberrations introduced to the output of a tiled array of coherently combinable beams. The experimental work performed for this effort resulted in the coherent combination of 32 low power optical beams operating with unprecedented LOCSET phase error performance of lambda/71 RMS in a local loop beam combination configuration. The LOCSET phase locking technique was also successfully extended, for the first time, into an Object In the Loop (OIL) configuration by utilizing light scattered off of a remote object as the optical return signal for the LOCSET phase control electronics. Said LOCSET-OIL technique is capable of correcting for low order phase aberrations caused by atmospheric turbulence disturbances applied across a tiled array output.

  12. Non-invasive diagnostic methods in dentistry

    NASA Astrophysics Data System (ADS)

    Todea, Carmen

    2016-03-01

    The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.

  13. Genetic Diagnostic Methods for Inherited Eye Diseases

    PubMed Central

    Gabriel, Luis A. R.; Traboulsi, Elias I.

    2011-01-01

    Accurate molecular diagnosis of genetic eye diseases has proven to be of great importance because of the prognostic and therapeutic value of an accurate ascertainment of the underlying genetic mutation. Efforts continue in diagnostic laboratories to develop strategies that allow the discovery of responsible gene/mutations in the individual patient using the least number of assays and economizing on the expenses and time involved in the process. Once the ophthalmologist has made the best possible clinical diagnosis, blood samples are obtained for genetic testing. In this paper we will review the basic laboratory methods utilized to identify the chromosomal or mutational etiology of genetic diseases that affect the eye. PMID:21572730

  14. Method of azimuthally stable Mueller-matrix diagnostics of blood plasma polycrystalline films in cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Ushenko, Yu. A.; Prysyazhnyuk, V. P.; Gavrylyak, M. S.; Gorsky, M. P.; Bachinskiy, V. T.; Vanchuliak, O. Ya.

    2015-02-01

    A new information optical technique of diagnostics of the structure of polycrystalline films of blood plasma is proposed. The model of Mueller-matrix description of mechanisms of optical anisotropy of such objects as optical activity, birefringence, as well as linear and circular dichroism is suggested. The ensemble of informationally topical azimuthally stable Mueller-matrix invariants is determined. Within the statistical analysis of such parameters distributions the objective criteria of differentiation of films of blood plasma taken from healthy and patients with liver cirrhosis were determined. From the point of view of probative medicine the operational characteristics (sensitivity, specificity and accuracy) of the information-optical method of Mueller-matrix mapping of polycrystalline films of blood plasma were found and its efficiency in diagnostics of liver cirrhosis was demonstrated. Prospects of application of the method in experimental medicine to differentiate postmortem changes of the myocardial tissue was examined.

  15. Is Musculoskeletal Ultrasonography an Operator-Dependent Method or a Fast and Reliably Teachable Diagnostic Tool? Interreader Agreements of Three Ultrasonographers with Different Training Levels

    PubMed Central

    Ohrndorf, Sarah; Naumann, Lydia; Grundey, Jessica; Scheel, Tanja; Scheel, Alexander K.; Werner, Carola; Backhaus, Marina

    2010-01-01

    Objectives. To assess interreader agreements and a learning curve between three (senior, junior, and beginner) different experienced musculoskeletal ultrasonographers. Senior served as the imaging “gold standard”. Methods. Clinically dominant joints (finger, shoulder, knee, tibiotalar, and talonavicular) of 15 rheumatoid arthritis (RA) patients were examined by three different experienced ultrasonographers (senior 10 years, junior 10 months, and beginner one month). Each patient's ultrasonographic findings were reported unaware of the other investigators' results. κ coefficients, percentage agreements, sensitivities, and specificities were calculated. Results. 120 joints of 15 RA patients were evaluated. Comparing junior's and beginner's results each to the senior's findings, the overall κ for all examined joints was 0.83 (93%) for junior and 0.43 (76%) for beginner. Regarding the different joints, junior's findings correlate very well with the senior's findings (finger joints: κ = 0.82; shoulder: κ = 0.9; knee: κ = 0.74; tibiotalar joint: κ = 0.84; talonavicular joint: κ = 0.84) while beginner's findings just showed fair to moderate agreements (finger joints: κ = 0.4; shoulder: κ = 0.42; knee: κ = 0.4; tibiotalar joint: κ = 0.59; talonavicular joint: κ = 0.35). In total, beginner's results clearly improved from κ = 0.34 (agreement of 67%) at baseline to κ = 0.78 (agreement of 89%) at the end of the evaluation period. Conclusions. Ultrasonographic evaluation of a ten-month-experienced investigator in comparison to a senior ultrasonographer was of substantial agreement. Agreements between a beginner and a highly experienced ultrasonographer were only fair at the beginning, but during the study including ultrasonographical sessions of 15 RA patients, the beginner clearly improved in musculoskeletal ultrasonography. PMID:21197088

  16. METHOD OF CENTRIFUGE OPERATION

    DOEpatents

    Cohen, K.

    1960-05-10

    A method of isotope separation is described in which two streams are flowed axially of, and countercurrently through, a cylindrical centrifuge bowl. Under the influence of a centrifugal field, the light fraction is concentrated in a stream flowing through the central portion of the bowl, whereas the heavy fraction is concentrated in a stream at the periphery thereof.

  17. Current status of diagnostic methods for henipavirus.

    PubMed

    Tamin, A; Rota, P A

    2013-01-01

    Hendra virus (HeV) and Nipah virus (NiV) are the causative agents of emerging transboundary animal disease in pigs and horses. They also cause fatal disease in humans. NiV has a case fatality rate of 40 - 100%. In the initial NiV outbreak in Malaysia in 1999, about 1.1 million pigs had to be culled. The economic impact was estimated to be approximately US$450 million. Worldwide, HeV has caused more than 60 deaths in horses with 7 human cases and 4 deaths. Since the initial outbreak, HeV spillovers from Pteropus bats to horses and humans continue. This article presents a brief review on the currently available diagnostic methods for henipavirus infections, including advances achieved since the initial outbreak, and a gap analysis of areas needing improvement. PMID:23689891

  18. Performance of different categories of operators in simulated diagnostic colonoscopy.

    PubMed

    Fasoli, Renato; Pertile, Riccardo; Seligman, Sonia; de Pretis, Giovanni

    2015-01-01

    The possible involvement, although limited to the diagnostic phase of the procedure, of nonmedical staff (particularly endoscopy nurses) in lower digestive endoscopy has recently been suggested. Computer-based simulators have demonstrated objective evaluation of technical skills in digestive endoscopy. The aim of this study was to evaluate basic colonoscopy skills of endoscopy nurses (naive operators), as compared with junior physician staff and senior endoscopists, through a virtual reality colonoscopy simulator. In this single-center, prospective, nonrandomized study, 3 groups of digestive endoscopy operators (endoscopy nurses, junior doctors [<150 previous colonoscopies], expert doctors [>500 previous colonoscopies and >200/year]) completed six diagnostic cases generated by an endoscopic simulator (AccuTouch, Immersion Medical, Gaithersburg, MD). The performance parameters, collected by the simulator, were compared between groups. Five parameters have been considered for statistical analysis: time spent to reach the cecum; pain of any degree; severe/extreme pain; amount of insufflated air; percentage of visualized mucosa. Statistical analysis to compare the three groups has been performed by means of Wilcoxon test for two independent samples and by means of Kruskal-Wallis test for three independent samples (p < .05). Sixteen operators have been studied (six endoscopy nurses, five junior doctors, and five senior doctors); 96 colonoscopic procedures have been evaluated. Statistically significant differences between experts and naive operators were observed regarding time to reach the cecum and induction of severe/extreme pain, with both Kruskal-Wallis and Wilcoxon test (p < .05); all other comparisons did not reach statistical significance. Although, as expected, expert doctors exceeded both junior doctors and naive operators in some relevant quality parameters of simulated diagnostic colonoscopies, the results obtained by less expert performers--and particularly

  19. [Categorical and dimensional diagnostic approach to acute psychosis in view of operational diagnostic criteria].

    PubMed

    Sakamoto, Kaoru

    2011-01-01

    "Acute psychosis" is the tentative diagnosis made for the patients presenting acute onset of delusion, hallucination, confusion and emotional instability. "Acute psychosis" was focused in view of operational diagnostic criteria, ie, DSM-IV-TR and ICD-10. The diagnostic categories in the DSM-IV-TR corresponding to "acute psychosis" were brief psychotic disorder, schizophreniform disorder, schizo-affective disorder and mood disorder with psychotic features. Although brief psychotic disorder is representative of "acute psychosis" in the DSM-TR, it lacks in clinical usefulness, because its diagnostic criteria, based on no historical background, lack clinical validity in terms of symptom definition and duration (1 month>). On the other hand, in the ICD-10, a diagnostic category of acute transient psychotic disorder was based on the traditional "acute psychosis" concept that has been bred in the European Psychiatry. Among the acute transient psychotic disorders, acute polymorphic psychotic disorder is the diagnostic category made according to traditional concept of "bouffées délirantes" and cycloid psychosis. It is a clinically useful diagnostic category, because it could predict favorable episode outcome, if a person with fairly good premorbid social adaptation presents acute onset of polymorphic psychotic symptoms. One of the most prominent points of the revision of DSM-IV-TR to DSM-5 is the adoption of dimensional approach evaluation (diagnosis) in a disorder-crossing fashion. In addition to insomnia, depressive mood and anxiety, symptomatic domain such as acute onset, bipolarity, polymorphism of psychotic symptoms, and furthermore such domain as premorbid social adaptation, life event and episode outcome should be evaluated in the course of treatment, contributing to the clinical practice of the patients with acute psychosis. PMID:22352007

  20. Ultrasensitive microanalytical diagnostic methods for rickettsial pathogens

    SciTech Connect

    Hatch, A. V.

    2012-03-01

    A strategic CRADA was established between Sandia National Laboratories (SNL) and the University of Texas Medical Branch (UTMB) at Galveston to address pressing needs for US protection against biological weapons of mass destruction (WMD) and emerging infectious diseases. The combination of unique expertise and facilities at UTMB and SNL enabled interdisciplinary research efforts in the development of rapid and accurate diagnostic methods for early detection of trace priority pathogen levels. Outstanding postdoctoral students were also trained at both institutions to help enable the next generation of scientists to tackle the challenging interdisciplinary problems in the area of biodefense and emerging infectious diseases. Novel approaches to diagnostics were developed and the both the speed of assays as well as the detection sensitivity were improved by over an order of magnitude compared to traditional methods. This is a significant step toward more timely and specific detection of dangerous infections. We developed in situ polymerized porous polymer monoliths that can be used as (1) size exclusion elements for capture and processing of rickettsial infected cells from a sample, (2) photopatternable framework for grafting high densities of functionalized antibodies/fluorescent particles using novel monolith chemistry. Grafting affinity reagents specific to rickettsial particles enables rapid, ultra-sensitive assays by overcoming transport limitations of traditional planar assay approaches. We have selectively trapped particles and bacteria at the cell trap and have also detected picomolar mouse IL-6 captured with only 20 minutes total incubation times using the densely patterned monolith framework. As predicted, the monolith exhibits >10x improvements in both capture speed and capture density compared to traditional planar approaches. The most significant advancements as part of this CRADA is the optimization of techniques allowing the detection of <10 rickettsial

  1. Monitoring and diagnostics systems for nuclear power plant operating regimes

    SciTech Connect

    Abagyan, A.A.; Dmitriev, V.M.; Klebanov, L.A.; Kroshilin, A.E.; Larin, E.P.; Morozov, S.K.

    1988-05-01

    The development of new monitoring and diagnostics systems for Soviet reactors is discussed. An experimental test station is described where industrial operation of new experimental systems can be conducted for purposes of bringing their performance to the level of standard Soviet systems for monitoring reactor operation regimes and equipment resources. The requirements and parameters of the systems are described on a unit-by-unit basis, including the sensor reading monitoring unit, the vibroacoustic monitoring unit, the noise monitoring unit, the accident regime identification unit, and the nonstationary regime monitoring unit. Computer hardware and software requirements are discussed. The results of calculational and experimental research on two complex nonstationary regimes of reactor operation are given. The accident regimes identification unit for the VVER-1000 is analyzed in detail.

  2. [Clinical importance and diagnostic methods of minimal hepatic encephalopathy].

    PubMed

    Stawicka, Agnieszka; Zbrzeźniak, Justyna; Świderska, Aleksandra; Kilisińska, Natalia; Świderska, Magdalena; Jaroszewicz, Jerzy; Flisiak, Robert

    2016-02-01

    Minimal hepatic encephalopathy (MHE) encompasses a number of neuropsychological and neurophysiological disorders in patients suffering from liver cirrhosis, who do not display abnormalities during a medical interview or physical examination. A negative influence of MHE on the quality of life of patients suffering from liver cirrhosis was confirmed, which include retardation of ability of operating motor vehicles and disruption of multiple health-related areas, as well as functioning in the society. The data on frequency of traffic offences and accidents amongst patients diagnosed with MHE in comparison to patients diagnosed with liver cirrhosis without MHE, as well as healthy persons is alarming. Those patients are unaware of their disorder and retardation of their ability to operate vehicles, therefore it is of utmost importance to define this group. The term minimal hepatic encephalopathy (formerly "subclinical" encephalopathy) erroneously suggested the unnecessity of diagnostic and therapeutic procedures in patients with liver cirrhosis. Diagnosing MHE is an important predictive factor for occurrence of overt encephalopathy - more than 50% of patients with this diagnosis develop overt encephalopathy during a period of 30 months after. Early diagnosing MHE gives a chance to implement proper treatment which can be a prevention of overt encephalopathy. Due to continuing lack of clinical research there exist no commonly agreed-upon standards for definition, diagnostics, classification and treatment of hepatic encephalopathy. This article introduces the newest findings regarding the importance of MHE, scientific recommendations and provides detailed descriptions of the most valuable diagnostic methods. PMID:27000818

  3. Comparison of Diagnostic Methods for Asperger Syndrome

    ERIC Educational Resources Information Center

    Kopra, Kristiina; von Wendt, Lennart; Nieminen-von Wendt, Taina; Paavonen, E. Julia

    2008-01-01

    Several different diagnostic sets of criteria exist for Asperger syndrome (AS), but there is no agreement on a gold standard. The aim of this study was to compare four diagnostic sets of criteria for AS: the ICD-10, the DSM-IV, the Gillberg & Gillberg, and the Szatmari criteria. The series consists of 36 children who had been referred to two…

  4. Fault diagnosis using a diagnostic shell and its verification results by connecting to an operator training simulator

    SciTech Connect

    Kobayashi, T.; Moridera, D.; Komai, K.; Fukui, S.; Matsumoto, K.

    1995-02-01

    This paper describes a fault diagnostic system using a diagnostic shell, MELDASH, and results that confirm its effectiveness. The diagnostic shell that reflects and makes use of the nature of model-based diagnosis is developed to overcome the drawbacks of methods that depend on operator knowledge. A high-performance fault diagnostic system is constructed simply by adding an application model to the diagnostic shell. A prototype system is verified by connecting it to an operator training simulator. It is able to make a proper diagnosis in 79 difficult fault cases. Verification results shows that the prototype system has sufficient accuracy. The authors confirm the effectiveness of this fault diagnostic method for future energy management systems.

  5. Diagnostic Methods in Primary Ciliary Dyskinesia.

    PubMed

    Lucas, Jane S; Paff, Tamara; Goggin, Patricia; Haarman, Eric

    2016-03-01

    Diagnosing primary ciliary dyskinesia is difficult. With no reference standard, a combination of tests is needed; most tests require expensive equipment and specialist scientists. We review the advances in diagnostic testing over the past hundred years, with emphasis on recent advances. We particularly focus on use of high-speed video analysis, transmission electron microscopy, nasal nitric oxide and genetic testing. We discuss the international efforts that are in place to advance the evidence base for diagnostic tests. PMID:26362507

  6. Ac electrode diagnostics in ac-operated metal halide lamps

    NASA Astrophysics Data System (ADS)

    Luijks, G. M. J. F.; van Esveld, H. A.; Nijdam, S.; Weerdesteijn, P. A. M.

    2008-07-01

    A diagnostic technique is presented to determine the electrode work function in ac-operated metal halide lamps. The heart of the experimental set-up is a high-speed photodiode array detector, which is able to follow real-time variations of electrode tip temperature and near-electrode plasma emissions in ac-operated experimental YAG lamps, enabling discrimination between the anode and cathode effects. Electrode tip temperature ripples have been measured for 100 Hz square wave operation and simulated with an existing electrode model. By using the electrode work function as main fit parameter for the simulations it is found that the measured cooling effect of the electrode tip in a NaTlDy-iodide lamp is caused by a gas-phase emitter effect of Dy. It is concluded that Dy coverage of the electrode tip causes an effective work function reduction of 0.3 eV at 100 Hz square wave operation, considerably less than the 1.0 eV reduction measured earlier for dc operation.

  7. TPX diagnostics for tokamak operation, plasma control and machine protection

    SciTech Connect

    Edmonds, P.H.; Medley, S.S.; Young, K.M.

    1995-08-01

    The diagnostics for TPX are at an early design phase, with emphasis on the diagnostic access interface with the major tokamak components. Account has to be taken of the very severe environment for diagnostic components located inside the vacuum vessel. The placement of subcontracts for the design and fabrication of the diagnostic systems is in process.

  8. Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

  9. Method and apparatus for holographic wavefront diagnostics

    DOEpatents

    Toeppen, John S.

    1995-01-01

    A wavefront diagnostic apparatus has an optic and a measuring system. The optic forms a holographic image in response to a beam of light striking a hologram formed on a surface of the optic. The measuring system detects the position of the array of holographic images and compares the positions of the array of holographic images to a reference holographic image.

  10. Method and apparatus for holographic wavefront diagnostics

    DOEpatents

    Toeppen, J.S.

    1995-04-25

    A wavefront diagnostic apparatus has an optic and a measuring system. The optic forms a holographic image in response to a beam of light striking a hologram formed on a surface of the optic. The measuring system detects the position of the array of holographic images and compares the positions of the array of holographic images to a reference holographic image. 3 figs.

  11. Status of the diagnostics development for the first operation phase of the stellarator Wendelstein 7-X

    SciTech Connect

    König, R. Biedermann, C.; Burhenn, R.; Endler, M.; Grulke, O.; Hathiramani, D.; Hirsch, M.; Jakubowski, M.; Kornejew, P.; Krychowiak, M.; Langenberg, A.; Laux, M.; Lorenz, A.; Otte, M.; Pasch, E.; Pedersen, T. S.; Schneider, W.; Thomsen, H.; Windisch, T.; Zhang, D.; and others

    2014-11-15

    An overview of the diagnostics which are essential for the first operational phase of Wendelstein 7-X and the set of diagnostics expected to be ready for operation at this time are presented. The ongoing investigations of how to cope with high levels of stray Electron Cyclotron Resonance Heating (ECRH) radiation in the ultraviolet (UV)/visible/infrared (IR) optical diagnostics are described.

  12. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    SciTech Connect

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  13. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  14. [Diagnostic methods of nasal respiratory function].

    PubMed

    Mlynski, G; Beule, A

    2008-01-01

    Objective assessment of nasal obstruction may help with preoperative planning for rhinosurgery and indicate different aspects of endonasal pathology. To improve quality control, preoperative and postoperative objective assessment is desirable. This review presents objective functional diagnostic tools and explains their appropriate uses, the information obtained, and their limitations. An algorithm is presented for analysing nasal obstruction by means of objective functional assessment. Examples illustrate how to use this information for preoperative planning in rhinosurgery. PMID:18210011

  15. Pertussis: the disease and new diagnostic methods.

    PubMed Central

    Friedman, R L

    1988-01-01

    Bordetella pertussis, the causative agent of whooping cough, produces an acute and chronic respiratory infection in infants and young children. B. pertussis is still a major health problem of young children throughout the world even though effective immunization against whooping cough is available. While predominantly a childhood disease, it has been reported also to be a cause of persistent cough in adults. This review discusses the numerous bacterial virulence factors that may play roles in the pathogenesis of pertussis and in immunity to infection. The present problems with pertussis diagnosis, recent advances, and future prospects for new and improved rapid diagnostics tests also are explored. PMID:2906814

  16. Diagnostic methods for CW laser damage testing

    NASA Astrophysics Data System (ADS)

    Stewart, Alan F.; Shah, Rashmi S.

    2004-06-01

    High performance optical coatings are an enabling technology for many applications - navigation systems, telecom, fusion, advanced measurement systems of many types as well as directed energy weapons. The results of recent testing of superior optical coatings conducted at high flux levels will be presented. The diagnostics used in this type of nondestructive testing and the analysis of the data demonstrates the evolution of test methodology. Comparison of performance data under load to the predictions of thermal and optical models shows excellent agreement. These tests serve to anchor the models and validate the performance of the materials and coatings.

  17. Diagnostic methods of solar cells in dependence on temperature

    NASA Astrophysics Data System (ADS)

    Dolensky, J.; Vesely, A.; Vanek, J.; Hrozek, J.

    2009-08-01

    This study is focused on testing methods determining quality of solar cells. Nowadays the development of solar cells is much faster and there is still necessary to increase their quality by removing causes of materials defects and also defects in a process of their production. Non-destructive methods are used for correct determination of defects by using of recombination effect of charge carrier in PN junction. Due to these methods can be the solar cell diagnosed and described. By using of various temperatures during the testing we can receive more objective results thanks to simulated operation conditions. Peltier cells are used for graditional change of temperature. Cooling system with liquid nitro - LN2 is used to reach the very low temperature. Diagnostic and testing methods described in this study are based on emission of light and the recombination processes in PN junction. It is especially electroluminescence and photoluminescence method. For comparison it is used the observation of emitted light from microplasma method. Described methods detect materials and process defects due to use of lownoise and very sensitive CCD camera.

  18. METHOD OF OPERATING A CALUTRON

    DOEpatents

    Davidson, P.H.

    1960-01-12

    A method of operating an electromagnetic isotope separator of the calutron class is reported whereby uranium tetrachloride is produced at a controlled rate within the source rather than betng introduced therein as was formerly practiced. This is accomplished by placing a uranium-bearing material, such as uranium metal, uranium trichloride, or uranium carbide in the charge receptacle of the calutron, heating this material to about to produce uranium tetrachloride vapor at a rate controlled by the chlorine gas flow into the source. The vapor is subsequently ionized by an electric arc and mass separated by conventional calutron methods.

  19. Method and system for diagnostics of apparatus

    NASA Technical Reports Server (NTRS)

    Gorinevsky, Dimitry (Inventor)

    2012-01-01

    Proposed is a method, implemented in software, for estimating fault state of an apparatus outfitted with sensors. At each execution period the method processes sensor data from the apparatus to obtain a set of parity parameters, which are further used for estimating fault state. The estimation method formulates a convex optimization problem for each fault hypothesis and employs a convex solver to compute fault parameter estimates and fault likelihoods for each fault hypothesis. The highest likelihoods and corresponding parameter estimates are transmitted to a display device or an automated decision and control system. The obtained accurate estimate of fault state can be used to improve safety, performance, or maintenance processes for the apparatus.

  20. Propulsion Diagnostic Method Evaluation Strategy (ProDiMES) User's Guide

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2010-01-01

    This report is a User's Guide for the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES). ProDiMES is a standard benchmarking problem and a set of evaluation metrics to enable the comparison of candidate aircraft engine gas path diagnostic methods. This Matlab (The Mathworks, Inc.) based software tool enables users to independently develop and evaluate diagnostic methods. Additionally, a set of blind test case data is also distributed as part of the software. This will enable the side-by-side comparison of diagnostic approaches developed by multiple users. The Users Guide describes the various components of ProDiMES, and provides instructions for the installation and operation of the tool.

  1. Diagnostic Value of Halitosis Examination Methods.

    PubMed

    Aydin, Murat; Bollen, Curd M L; Özen, Murat Eren

    2016-03-01

    There are many methods and varied protocols for examining halitosis. Chemical and enzymatic tests determine the presence of bacterial species and their metabolic products or enzymes in the mouth, while halitometers precisely quantify gases but not halitosis itself. Examinations by the human nose (ie, self assessment, feedback from others, or organoleptic test by an examiner) directly target halitosis, however organoleptic examination alone is insufficient for a definitive diagnosis when the individual has no complaints about halitosis. The underlying reasons why patients seek consultation concerning halitosis are usually based on their own assessment and the opinion of others, even if those assessments are not correlated with oral odorous gas measurements. This article seeks to summarize findings and review methods of examining halitosis to determine their usefulness. PMID:26977897

  2. METHOD OF OPERATING NUCLEAR REACTORS

    DOEpatents

    Untermyer, S.

    1958-10-14

    A method is presented for obtaining enhanced utilization of natural uranium in heavy water moderated nuclear reactors by charging the reactor with an equal number of fuel elements formed of natural uranium and of fuel elements formed of uranium depleted in U/sup 235/ to the extent that the combination will just support a chain reaction. The reactor is operated until the rate of burnup of plutonium equals its rate of production, the fuel elements are processed to recover plutonium, the depleted uranium is discarded, and the remaining uranium is formed into fuel elements. These fuel elements are charged into a reactor along with an equal number of fuel elements formed of uranium depleted in U/sup 235/ to the extent that the combination will just support a chain reaction, and reuse of the uranium is continued as aforesaid until it wlll no longer support a chain reaction when combined with an equal quantity of natural uranium.

  3. Signal processing methods for MFE plasma diagnostics

    SciTech Connect

    Candy, J.V.; Casper, T.; Kane, R.

    1985-02-01

    The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL.

  4. Potentials and limitations of molecular diagnostic methods in food safety

    PubMed Central

    Mariani, Paola O.

    2008-01-01

    Molecular methods allow the detection of pathogen nucleic acids (DNA and RNA) and, therefore, the detection of contamination in food is carried out with high selectivity and rapidity. In the last 2 decades molecular methods have accompanied traditional diagnostic methods in routine pathogen detection, and might replace them in the upcoming future. In this review the implementation in diagnostics of four of the most used molecular techniques (PCR, NASBA, microarray, LDR) are described and compared, highlighting advantages and limitations of each of them. Drawbacks of molecular methods with regard to traditional ones and the difficulties encountered in pathogen detection from food or clinical specimen are also discussed. Moreover, criteria for the choice of the target sequence for a secure detection and classification of pathogens and possible developments in molecular diagnostics are also proposed. PMID:19067016

  5. Computer methods for ITER-like materials LIBS diagnostics

    NASA Astrophysics Data System (ADS)

    Łepek, Michał; GÄ sior, Paweł

    2014-11-01

    Recent development of Laser-Induced Breakdown Spectroscopy (LIBS) caused that this method is considered as the most promising for future diagnostic applications for characterization of the deposited materials in the International Thermonuclear Experimental Reactor (ITER), which is currently under construction. In this article the basics of LIBS are shortly discussed and the software for spectra analyzing is presented. The main software function is to analyze measured spectra with respect to the certain element lines presence. Some program operation results are presented. Correct results for graphite and aluminum are obtained although identification of tungsten lines is a problem. The reason for this is low tungsten lines intensity, and thus low signal to noise ratio of the measured signal. In the second part artificial neural networks (ANNs) as the next step for LIBS spectra analyzing are proposed. The idea is focused on multilayer perceptron network (MLP) with backpropagation learning method. The potential of ANNs for data processing was proved through application in several LIBS-related domains, e.g. differentiating ancient Greek ceramics (discussed). The idea is to apply an ANN for determination of W, Al, C presence on ITER-like plasma-facing materials.

  6. Differential temperature integrating diagnostic method and apparatus

    DOEpatents

    Doss, James D.; McCabe, Charles W.

    1976-01-01

    A method and device for detecting the presence of breast cancer in women by integrating the temperature difference between the temperature of a normal breast and that of a breast having a malignant tumor. The breast-receiving cups of a brassiere are each provided with thermally conductive material next to the skin, with a thermistor attached to the thermally conductive material in each cup. The thermistors are connected to adjacent arms of a Wheatstone bridge. Unbalance currents in the bridge are integrated with respect to time by means of an electrochemical integrator. In the absence of a tumor, both breasts maintain substantially the same temperature, and the bridge remains balanced. If the tumor is present in one breast, a higher temperature in that breast unbalances the bridge and the electrochemical cells integrate the temperature difference with respect to time.

  7. Examinations of electron temperature calculation methods in Thomson scattering diagnostics

    SciTech Connect

    Oh, Seungtae; Lee, Jong Ha; Wi, Hanmin

    2012-10-15

    Electron temperature from Thomson scattering diagnostic is derived through indirect calculation based on theoretical model. {chi}-square test is commonly used in the calculation, and the reliability of the calculation method highly depends on the noise level of input signals. In the simulations, noise effects of the {chi}-square test are examined and scale factor test is proposed as an alternative method.

  8. Aircraft operability methods applied to space launch vehicles

    SciTech Connect

    Young, D.

    1997-01-01

    The commercial space launch market requirement for low vehicle operations costs necessitates the application of methods and technologies developed and proven for complex aircraft systems. The {open_quotes}building in{close_quotes} of reliability and maintainability, which is applied extensively in the aircraft industry, has yet to be applied to the maximum extent possible on launch vehicles. Use of vehicle system and structural health monitoring, automated ground systems and diagnostic design methods derived from aircraft applications support the goal of achieving low cost launch vehicle operations. Transforming these operability techniques to space applications where diagnostic effectiveness has significantly different metrics is critical to the success of future launch systems. These concepts will be discussed with reference to broad launch vehicle applicability. Lessons learned and techniques used in the adaptation of these methods will be outlined drawing from recent aircraft programs and implementation on phase 1 of the X-33/RLV technology development program. {copyright} {ital 1997 American Institute of Physics.}

  9. Aircraft operability methods applied to space launch vehicles

    NASA Astrophysics Data System (ADS)

    Young, Douglas

    1997-01-01

    The commercial space launch market requirement for low vehicle operations costs necessitates the application of methods and technologies developed and proven for complex aircraft systems. The ``building in'' of reliability and maintainability, which is applied extensively in the aircraft industry, has yet to be applied to the maximum extent possible on launch vehicles. Use of vehicle system and structural health monitoring, automated ground systems and diagnostic design methods derived from aircraft applications support the goal of achieving low cost launch vehicle operations. Transforming these operability techniques to space applications where diagnostic effectiveness has significantly different metrics is critical to the success of future launch systems. These concepts will be discussed with reference to broad launch vehicle applicability. Lessons learned and techniques used in the adaptation of these methods will be outlined drawing from recent aircraft programs and implementation on phase 1 of the X-33/RLV technology development program.

  10. [Cognitive functions, their development and modern diagnostic methods].

    PubMed

    Klasik, Adam; Janas-Kozik, Małgorzata; Krupka-Matuszczyk, Irena; Augustyniak, Ewa

    2006-01-01

    provided a theory. The psychometric approach concentrates on studying the differences in intelligence. The aim of this approach is to test intelligence by means of standardized tests (e.g. WISC-R, WAIS-R) used to show the individual differences among humans. Human cognitive functions determine individuals' adaptation capabilities and disturbances in this area indicate a number of psychopathological changes and are a symptom enabling to differentiate or diagnose one with a disorder. That is why the psychological assessment of cognitive functions is an important part of patients' diagnosis. Contemporary neuropsychological studies are to a great extent based computer tests. The use of computer methods has a number of measurement-related advantages. It allows for standardized testing environment, increasing therefore its reliability and standardizes the patient assessment process. Special attention should be paid to the neuropsychological tests included in the Vienna Test System (Cognitron, SIGNAL, RT, VIGIL, DAUF), which are used to assess the operational memory span, learning processes, reaction time, attention selective function, attention continuity as well as attention interference resistance. It also seems justified to present the CPT id test (Continuous Performance Test) as well as Free Recall. CPT is a diagnostic tool used to assess the attention selective function, attention continuity of attention, attention interference resistance as well as attention alertness. The Free Recall test is used in the memory processes diagnostics to assess patients' operational memory as well as the information organization degree in operational memory. The above mentioned neuropsychological tests are tools used in clinical assessment of cognitive function disorders. PMID:17471820

  11. Motor current signature analysis method for diagnosing motor operated devices

    DOEpatents

    Haynes, Howard D.; Eissenberg, David M.

    1990-01-01

    A motor current noise signature analysis method and apparatus for remotely monitoring the operating characteristics of an electric motor-operated device such as a motor-operated valve. Frequency domain signal analysis techniques are applied to a conditioned motor current signal to distinctly identify various operating parameters of the motor driven device from the motor current signature. The signature may be recorded and compared with subsequent signatures to detect operating abnormalities and degradation of the device. This diagnostic method does not require special equipment to be installed on the motor-operated device, and the current sensing may be performed at remote control locations, e.g., where the motor-operated devices are used in accessible or hostile environments.

  12. A method for knowledge acquisition in diagnostic expert system.

    PubMed

    Li, Weishi; Li, Aiping; Li, Shudong

    2015-01-01

    Knowledge acquisition plays very important role in the diagnostic expert system. It usually takes a long period to acquire disease knowledge using the traditional methods. To solve this problem, this paper describes relations between rough set theory and rule-based description of diseases, which corresponds to the process of knowledge acquisition of diagnostic expert system. Then the exclusive rules, inclusive rules and disease images of disease are built based on the PDES diagnosis model, and the definition of probability rule is put forward. At last, the paper presents the rule-based automated induction reasoning method, including exhaustive search, post-processing procedure, estimation for statistic test and the bootstrap and resampling methods. We also introduce automated induction of the rule-based description, which is used in our diseases diagnostic expert system. The experimental results not only show that rough set theory gives a very suitable framework to represent processes of uncertain knowledge extraction, but also that this method induces diagnostic rules correctly. This method can act as the assistant tool for development of diagnosis expert system, and has an extensive application in intelligent information systems. PMID:26410329

  13. Method to directly radiolabel antibodies for diagnostic imaging and therapy

    SciTech Connect

    Thakur, M.L.

    1991-04-30

    This patent describes a method for directly labeling proteins with radionuclides for use in diagnostic imaging and therapy. It comprises: the steps of incubating a protein-containing solution with a solution of sodium ascorbate; adding a required quantity of reduced radionuclide to the incubated protein-containing solution and incubating.

  14. Method to directly radiolabel antibodies for diagnostic imaging and therapy

    DOEpatents

    Thakur, Mathew L.

    1994-01-01

    The invention is a novel method and kit for directly radiolabeling proteins such as antibodies or antibody fragments for diagnostic and therapeutic purposes. The method comprises incubating a protein-containing solution with a solution of sodium ascorbate; adding a required quantity of reduced radionuclide to the incubated protein. A kit is also provided wherein the protein and/or reducing agents may be in lyophilized form.

  15. Method to directly radiolabel antibodies for diagnostic imaging and therapy

    DOEpatents

    Thakur, Mathew L.

    1991-01-01

    The invention is a novel method and kit for directly radiolabeling proteins such as antibodies or antibody fragments for diagnostic and therapeutic purposes. The method comprises incubating a protein-containing solution with a solution of sodium ascorbate; adding a required quantity of reduced radionuclide to the incubated protein. A kit is also provided wherein the protein and/or reducing agents may be in lyophilized form.

  16. Diagnostics design for steady-state operation of the Wendelstein 7-X stellarator

    SciTech Connect

    Koenig, R.; Baldzuhn, J.; Biedermann, C.; Burhenn, R.; Bozhenkov, S.; Cantarini, J.; Dreier, H.; Endler, M.; Hartfuss, H.-J.; Hildebrandt, D.; Hirsch, M.; Jakubowski, M.; Kornejev, P.; Krychowiak, M.; Laqua, H. P.; Laux, M.; Pasch, E.; Richert, T.; Schneider, W.; Svensson, J.; and others

    2010-10-15

    The status of the diagnostic developments for the quasistationary operable stellarator Wendelstein 7-X (maximum pulse length of 30 min at 10 MW ECRH heating at 140 GHz) will be reported on. Significant emphasis is being given to the issue of ECRH stray radiation shielding of in-vessel diagnostic components, which will be critical at high density operation requiring O2 and OXB heating.

  17. [The comparative characteristic of methods of laboratory diagnostic of opisthorchiasis].

    PubMed

    Starostina, O Iu; Paniushkina, I I

    2014-04-01

    The analysis of samples of blood serums and copromaterial from patients was carried out to evaluate effectiveness of diagnostic of opisthorchiasis invasion. The Kato-Miura technique of thick film under cellophane layer and sedimentation technique of acetic etheric precipitation were applied for parasitologic diagnostic. The technique of immunoenzymometric analysis was applied for serological diagnostic. The analysis of detection rate of eggs of opistorchis in copromaterial and level of anti-opistorchis antibodies in samples of blood serum of patients demonstrated the presence of strong direct correlation relationship between these indicators. It is demonstrated that for laboratory diagnostic of opisthorchiasis it is impossible to limit oneself to some single technique. It is established that on the territories with middle and low level of population infection rate of opistorchis it is appropriate to apply complex of methods including analysis of blood serum for presence of specific immunoglobulins to antigens of opistorchis and twice or thrice analysis of feces with copro-ovoscopic methods. PMID:25080800

  18. Molecular Diagnostic Methods for Detection and Characterization of Human Noroviruses.

    PubMed

    Chen, Haifeng; Hu, Yuan

    2016-01-01

    Human noroviruses are a group of viral agents that afflict people of all age groups. The viruses are now recognized as the most common causative agent of nonbacterial acute gastroenteritis and foodborne viral illness worldwide. However, they have been considered to play insignificant roles in the disease burden of acute gastroenteritis for the past decades until the recent advent of new and more sensitive molecular diagnostic methods. The availability and application of the molecular diagnostic methods have led to enhanced detection of noroviruses in clinical, food and environmental samples, significantly increasing the recognition of noroviruses as an etiologic agent of epidemic and sporadic acute gastroenteritis. This article aims to summarize recent efforts made for the development of molecular methods for the detection and characterization of human noroviruses. PMID:27335620

  19. Molecular Diagnostic Methods for Detection and Characterization of Human Noroviruses

    PubMed Central

    Chen, Haifeng; Hu, Yuan

    2016-01-01

    Human noroviruses are a group of viral agents that afflict people of all age groups. The viruses are now recognized as the most common causative agent of nonbacterial acute gastroenteritis and foodborne viral illness worldwide. However, they have been considered to play insignificant roles in the disease burden of acute gastroenteritis for the past decades until the recent advent of new and more sensitive molecular diagnostic methods. The availability and application of the molecular diagnostic methods have led to enhanced detection of noroviruses in clinical, food and environmental samples, significantly increasing the recognition of noroviruses as an etiologic agent of epidemic and sporadic acute gastroenteritis. This article aims to summarize recent efforts made for the development of molecular methods for the detection and characterization of human noroviruses. PMID:27335620

  20. Patenting genetic diagnostic methods: NGS, GWAS, SNPs and patents.

    PubMed

    Lawson, Charles

    2015-06-01

    This article reviews the problems posed by patent claims to genetic diagnostic methods associated with genome-wide association studies (GWAS) adopting methodologies using next-generation sequencing (NGS) and single nucleotide polymorphisms (SNP). These problems are essentially about experimental reproducibility and the credibility and veracity of reported developments. An analysis of the relevant law demonstrates that the current Australian and United States laws about suitable patentable subject matter differ, and that the current reproducibility (sufficiency, enablement and inutility) standards are unlikely to address these problems. The article concludes that following the United States approach excluding these genetic diagnostic method claims from patenting is one solution. Failing this, improving analysis and quality controls that are now being adopted in the basic research will reduce the nature of the problems, although this will remain problematic for patent examiners and the broader public. PMID:26349382

  1. INITIAL OPERATION OF THE LEDA BEAM-INDUCED FLUORESCENCE DIAGNOSTIC

    SciTech Connect

    J. KAMPERSCHROER; ET AL

    2000-06-01

    A diagnostic based on beam-induced fluorescence has been developed and used to examine the expanded beam in the High-Energy Beam Transport (HEBT) section of the Low Energy Demonstration Accelerator (LEDA). The system consists of a camera, a gas injector, a spectrometer, and a control system. Gas is injected to provide a medium for the beam to excite, the camera captures the resulting image of the fluorescing gas, and the spectrometer measures the spectrum of the emitted light. EPICS was used to control the camera and acquire and store images. Data analysis is presently being performed offline. A Kodak DCS420m professional CCD camera is the primary component of the optical system. InterScience, Inc. modified the camera with the addition of a gain of 4000 image intensifier, thereby producing an intensified camera with a sensitivity of {approximately}0.5 milli-lux. Light is gathered with a 1 inch format, 16-160 mm, Computar zoom lens. This lens is attached to the camera via a Century Precision Optics relay lens. Images obtained using only hydrogen from the beam stop exhibited features not yet understood. Images with good signal-to-noise ratio were obtained with the injection of sufficient nitrogen to raise the HEBT pressure to 2-8x10{sup {minus}6} torr. Two strong nitrogen lines, believed to be of the first negative group of N{sub 2}{sup +}, were identified at 391 and 428 nm.

  2. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies

    PubMed Central

    Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491

  3. Benchmarking Gas Path Diagnostic Methods: A Public Approach

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Bird, Jeff; Davison, Craig; Volponi, Al; Iverson, R. Eugene

    2008-01-01

    Recent technology reviews have identified the need for objective assessments of engine health management (EHM) technology. The need is two-fold: technology developers require relevant data and problems to design and validate new algorithms and techniques while engine system integrators and operators need practical tools to direct development and then evaluate the effectiveness of proposed solutions. This paper presents a publicly available gas path diagnostic benchmark problem that has been developed by the Propulsion and Power Systems Panel of The Technical Cooperation Program (TTCP) to help address these needs. The problem is coded in MATLAB (The MathWorks, Inc.) and coupled with a non-linear turbofan engine simulation to produce "snap-shot" measurements, with relevant noise levels, as if collected from a fleet of engines over their lifetime of use. Each engine within the fleet will experience unique operating and deterioration profiles, and may encounter randomly occurring relevant gas path faults including sensor, actuator and component faults. The challenge to the EHM community is to develop gas path diagnostic algorithms to reliably perform fault detection and isolation. An example solution to the benchmark problem is provided along with associated evaluation metrics. A plan is presented to disseminate this benchmark problem to the engine health management technical community and invite technology solutions.

  4. A multivariate method for meta-analysis and comparison of diagnostic tests.

    PubMed

    Dimou, Niki L; Adam, Maria; Bagos, Pantelis G

    2016-09-10

    We present here an extension of the classic bivariate random effects meta-analysis for the log-transformed sensitivity and specificity that can be applied for two or more diagnostic tests. The advantage of this method is that a closed-form expression is derived for the calculation of the within-studies covariances. The method allows the direct calculation of sensitivity and specificity, as well as, the diagnostic odds ratio, the area under curve and the parameters of the summary receiver operator's characteristic curve, along with the means for a formal comparison of these quantities for different tests. There is no need for individual patient data or the simultaneous evaluation of both diagnostic tests in all studies. The method is simple and fast; it can be extended for several diagnostic tests and can be fitted in nearly all statistical packages. The method was evaluated in simulations and applied in a meta-analysis for the comparison of anti-cyclic citrullinated peptide antibody and rheumatoid factor for discriminating patients with rheumatoid arthritis, with encouraging results. Simulations suggest that the method is robust and more powerful compared with the standard bivariate approach that ignores the correlation between tests. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26940666

  5. Post- and prenatal diagnostic methods for the homocystinurias.

    PubMed

    Fowler, B; Jakobs, C

    1998-04-01

    Diagnosis of the homozygous homocystinurias can be performed by investigations at the metabolite, enzyme and DNA level. The existence of variant forms due to the wide range of genetic variation may result in only small differences in various parameters between controls and affected subjects. 1. Sulphur amino acid concentrations in plasma, especially total homocysteine, are useful in first line diagnostic investigations. 2. Cystathionine-beta-synthase (CBS), methylenetetrahydrofolate reductase (MTHFR) and methylfolate homocysteine methyltransferase (MFMT) can be directly assayed in many tissues including fibroblasts (each) and blood cells (except CBS). Indirect whole cell assays which measure pathway activity dependent on a particular enzyme can provide useful diagnostic information. 3. Direct analysis of mutations is available for CBS, MTHFR and recently also for MFMT deficiencies. However the existence of a larger number of very rare, often private, mutations limits the usefulness of this approach in routine diagnosis. The above diagnostic approaches can generally be applied to prenatal diagnosis. Measurement of methylmalonic acid and other metabolites in amniotic fluid by stable isotope dilution / gas chromatography-mass spectrometry is well established for the methylmalonic acidurias. This method has also been applied to combined homocystinuria/methylmalonic aciduria supported by enzyme assays in cultured cells. Total homocysteine measurement in cell free amniotic fluid is also possible, performed so far in 14 cases with two affected fetuses. The indirect assay of methionine formation from [14C] labelled formate in intact cultured amniotic fluid cells has been for prenatal diagnosis of the remethylation defects. PMID:9587033

  6. Molecular and Nonmolecular Diagnostic Methods for Invasive Fungal Infections

    PubMed Central

    Arvanitis, Marios; Anagnostou, Theodora; Fuchs, Beth Burgwyn; Caliendo, Angela M.

    2014-01-01

    SUMMARY Invasive fungal infections constitute a serious threat to an ever-growing population of immunocompromised individuals and other individuals at risk. Traditional diagnostic methods, such as histopathology and culture, which are still considered the gold standards, have low sensitivity, which underscores the need for the development of new means of detecting fungal infectious agents. Indeed, novel serologic and molecular techniques have been developed and are currently under clinical evaluation. Tests like the galactomannan antigen test for aspergillosis and the β-glucan test for invasive Candida spp. and molds, as well as other antigen and antibody tests, for Cryptococcus spp., Pneumocystis spp., and dimorphic fungi, have already been established as important diagnostic approaches and are implemented in routine clinical practice. On the other hand, PCR and other molecular approaches, such as matrix-assisted laser desorption ionization (MALDI) and fluorescence in situ hybridization (FISH), have proved promising in clinical trials but still need to undergo standardization before their clinical use can become widespread. The purpose of this review is to highlight the different diagnostic approaches that are currently utilized or under development for invasive fungal infections and to identify their performance characteristics and the challenges associated with their use. PMID:24982319

  7. Application of modern diagnostic methods to environmental improvement. Annual progress report, January--October 1994

    SciTech Connect

    Shepard, W.S.

    1994-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), a research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to real world processes; measurements are made in hot, highly corrosive atmospheres in which conventional measurement devices are ineffective. Task 1 of this agreement is concerned with the development and application of various diagnostic methods to characterize the plasma properties, the melt properties and the downstream emissions from a plasma torch facility designed to vitrify mixed waste. Correlation of the measured properties with the operating parameters of the torch will be sought to improve, optimize and control the overall operation of the plasma treatment process. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and control purposes of treatment processes in general. Task 2 of this agreement is concerned with the development of a system to monitor and control the combustion stoichiometry in real time in order to minimize environmental impact and maximize process efficiency. Staged fuel injection is also being studied to minimize NO{sub x} formation.

  8. [Comparative diagnostic value of Helicobacter pylori infection testing methods].

    PubMed

    Girdalidze, A M; Elisabedashvili, G V; Sharvadze, L G; Dzhorbenadze, T A

    2013-12-01

    In 213 patients with gastric and duodenal pathology, including received surgery, comparative estimation of results of Helicobacter pylori (Hp) infection testing with invasive and noninvasive methods, were performed. Material for invasive endoscopic biopsy test (EBT), including rapid urease test (RUT) for rapid Hp identification by determination of urease activity, smear cytology and histology was extracted on endoscopy or intraoperationally. RUT was carried out with the help of URE-HP test kit. Serological test for Hp antibodies IgG and IgA class was performed by IFA using kit ELISA. 13С urea breath test (UBT) was made by determination of 13/12CO2 in breath samples on infrared spectroscope. Based on 5 different methods of Hp infection testing Hp positivity in 172 (80,8%) and Hp negativity in 41 (19,2%) from 213 examined patients was revealed. 13С-UBT revealed the highest diagnostic value (accuracy-97,5%, sensibility-97,0%, specificity-100%) in Hp infection diagnostics. In treatment efficiency control this parameters of 13С-UBT are also much high (96,7%, 90,0% and 100% respectively). In spite of high sensitivity of serological test (100%), it had comparative low specificity (71,0%) with high probability of false positive results in treated patients (antibodies titer to Hp after eradication retains for a long time). Thought, this test may be successfully used only in primary patients and in epidemiological studies. Among three methods of EBT, Hp infection detection with RUT revealed the best results (accuracy-94,8%, sensibility-95,0%, specificity-100%). Correlation of RUT and UBT results and much higher diagnostic value of UBT, necessitate RUT with histological study of stomach body mucosa to perform in patients over 45 year, with prolonged anamnesis and dangerous symptoms of disease. In Hp positive patients correlation of index DOB‰ of breath test with results of RUT was revealed. This can serve the index DOB‰ of 13С-UBT as a marker of Hp infection rate. The

  9. Real-time caries diagnostics by optical PNC method

    NASA Astrophysics Data System (ADS)

    Masychev, Victor I.; Alexandrov, Michail T.

    2000-11-01

    The results of hard tooth tissues research by the optical PNC- method in experimental and clinical conditions are presented. In the experiment under 90 test-sample of tooth slices with thickness about 1mm (enamel, dentine and cement) were researched. The results of the experiment were processed by the method of correlation analyze. Clinical researches were executed on teeth of 210 patients. The regions of tooth tissue diseases with initial, moderate and deep caries were investigated. Spectral characteristics of intact and pathologically changed tooth tissues are presented and their peculiar features are discussed. The results the optical PNC-method application while processing tooth carious cavities are presented in order to estimate efficiency of the mechanical and antiseptic processing of teeth. It is revealed that the PNC-method can be sued as for differential diagnostics of a degree dental carious stage, as for estimating of carefulness of tooth cavity processing before filling.

  10. Prognostic Analysis System and Methods of Operation

    NASA Technical Reports Server (NTRS)

    MacKey, Ryan M. E. (Inventor); Sneddon, Robert (Inventor)

    2014-01-01

    A prognostic analysis system and methods of operating the system are provided. In particular, a prognostic analysis system for the analysis of physical system health applicable to mechanical, electrical, chemical and optical systems and methods of operating the system are described herein.

  11. Method of operating a thermoelectric generator

    SciTech Connect

    Reynolds, Michael G; Cowgill, Joshua D

    2013-11-05

    A method for operating a thermoelectric generator supplying a variable-load component includes commanding the variable-load component to operate at a first output and determining a first load current and a first load voltage to the variable-load component while operating at the commanded first output. The method also includes commanding the variable-load component to operate at a second output and determining a second load current and a second load voltage to the variable-load component while operating at the commanded second output. The method includes calculating a maximum power output of the thermoelectric generator from the determined first load current and voltage and the determined second load current and voltage, and commanding the variable-load component to operate at a third output. The commanded third output is configured to draw the calculated maximum power output from the thermoelectric generator.

  12. Study on Fault Diagnostics of a Turboprop Engine Using Inverse Performance Model and Artificial Intelligent Methods

    NASA Astrophysics Data System (ADS)

    Kong, Changduk; Lim, Semyeong

    2011-12-01

    Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.

  13. Methods in virus diagnostics: from ELISA to next generation sequencing.

    PubMed

    Boonham, Neil; Kreuze, Jan; Winter, Stephan; van der Vlugt, René; Bergervoet, Jan; Tomlinson, Jenny; Mumford, Rick

    2014-06-24

    Despite the seemingly continuous development of newer and ever more elaborate methods for detecting and identifying viruses, very few of these new methods get adopted for routine use in testing laboratories, often despite the many and varied claimed advantages they possess. To understand why the rate of uptake of new technologies is so low, requires a strong understanding of what makes a good routine diagnostic tool to begin. This can be done by looking at the two most successfully established plant virus detection methods: enzyme-linked immunosorbant assay (ELISA) and more recently introduced real-time polymerase chain reaction (PCR). By examining the characteristics of this pair of technologies, it becomes clear that they share many benefits, such as an industry standard format and high levels of repeatability and reproducibility. These combine to make methods that are accessible to testing labs, which are easy to establish and robust in their use, even with new and inexperienced users. Hence, to ensure the establishment of new techniques it is necessary to not only provide benefits not found with ELISA or real-time PCR, but also to provide a platform that is easy to establish and use. In plant virus diagnostics, recent developments can be clustered into three core areas: (1) techniques that can be performed in the field or resource poor locations (e.g., loop-mediated isothermal amplification LAMP); (2) multiplex methods that are able to detect many viruses in a single test (e.g., Luminex bead arrays); and (3) methods suited to virus discovery (e.g., next generation sequencing, NGS). Field based methods are not new, with Lateral Flow Devices (LFDs) for the detection being available for a number of years now. However, the widespread uptake of this technology remains poor. LAMP does offer significant advantages over LFDs, in terms of sensitivity and generic application, but still faces challenges in terms of establishment. It is likely that the main barrier to the

  14. The Set of Diagnostics for the First Operation Campaign of the Wendelstein 7-X Stellarator

    NASA Astrophysics Data System (ADS)

    König, Ralf; Baldzuhn, J.; Biel, W.; Biedermann, C.; Bosch, H. S.; Bozhenkov, S.; Bräuer, T.; Brotas de Carvalho, B.; Burhenn, R.; Buttenschön, B.; Cseh, G.; Czarnecka, A.; Endler, M.; Erckmann, V.; Estrada, T.; Geiger, J.; Grulke, O.; Hartmann, D.; Hathiramani, D.; Hirsch, M.; Jabłonski, S.; Jakubowski, M.; Kaczmarczyk, J.; Klinger, T.; Klose, S.; Kocsis, G.; Kornejew, P.; Krämer-Flecken, A.; Kremeyer, T.; Krychowiak, M.; Kubkowska, M.; Langenberg, A.; Laqua, H. P.; Laux, M.; Liang, Y.; Lorenz, A.; Marchuk, A. O.; Moncada, V.; Neubauer, O.; Neuner, U.; Oosterbeek, J. W.; Otte, M.; Pablant, N.; Pasch, E.; Pedersen, T. S.; Rahbarnia, K.; Ryc, L.; Schmitz, O.; Schneider, W.; Schuhmacher, H.; Schweer, B.; Stange, T.; Thomsen, H.; Travere, J.-M.; Szepesi, T.; Wenzel, U.; Werner, A.; Wiegel, B.; Windisch, T.; Wolf, R.; Wurden, G. A.; Zhang, D.; Zimbal, A.; Zoletnik, S.; the W7-X Team

    2015-10-01

    Wendelstein 7-X (W7-X) is a large optimized stellarator (B=2.5T, V=30m3) aiming at demonstrating the reactor relevance of the optimized stellarators. In 2015 W7-X will begin its first operation phase (OP1.1) with five inertially cooled inboard limiters made of graphite. Assuming the heat loads can be spread out evenly between the limiters, 1 second discharges at 2 MW of ECRH heating power could be run in OP1.1. The expected plasma parameters will be sufficient to demonstrate the readiness of the installed diagnostics and even to run a first physics program. The diagnostics available for this first operation phase, including some special limiter diagnostics, and their capabilities are being presented. \\bigskip \

  15. A composite likelihood method for bivariate meta-analysis in diagnostic systematic reviews

    PubMed Central

    Liu, Yulun; Ning, Jing; Nie, Lei; Zhu, Hongjian; Chu, Haitao

    2014-01-01

    Diagnostic systematic review is a vital step in the evaluation of diagnostic technologies. In many applications, it involves pooling pairs of sensitivity and specificity of a dichotomized diagnostic test from multiple studies. We propose a composite likelihood method for bivariate meta-analysis in diagnostic systematic reviews. This method provides an alternative way to make inference on diagnostic measures such as sensitivity, specificity, likelihood ratios and diagnostic odds ratio. Its main advantages over the standard likelihood method are the avoidance of the non-convergence problem, which is non-trivial when the number of studies are relatively small, the computational simplicity and some robustness to model mis-specifications. Simulation studies show that the composite likelihood method maintains high relative efficiency compared to that of the standard likelihood method. We illustrate our method in a diagnostic review of the performance of contemporary diagnostic imaging technologies for detecting metastases in patients with melanoma. PMID:25512146

  16. New Methods and Transducer Designs for Ultrasonic Diagnostics and Therapy

    NASA Astrophysics Data System (ADS)

    Rybyanets, A. N.; Naumenko, A. A.; Sapozhnikov, O. A.; Khokhlova, V. A.

    Recent advances in the field of physical acoustics, imaging technologies, piezoelectric materials, and ultrasonic transducer design have led to emerging of novel methods and apparatus for ultrasonic diagnostics, therapy and body aesthetics. The paper presents the results on development and experimental study of different high intensity focused ultrasound (HIFU) transducers. Technological peculiarities of the HIFU transducer design as well as theoretical and numerical models of such transducers and the corresponding HIFU fields are discussed. Several HIFU transducers of different design have been fabricated using different advanced piezoelectric materials. Acoustic field measurements for those transducers have been performed using a calibrated fiber optic hydrophone and an ultrasonic measurement system (UMS). The results of ex vivo experiments with different tissues as well as in vivo experiments with blood vessels are presented that prove the efficacy, safety and selectivity of the developed HIFU transducers and methods.

  17. Real time diagnostic for operation at a CW low voltage FEL

    SciTech Connect

    Balfour, C.; Shaw, A.; Mayhew, S.E.

    1995-12-31

    At Liverpool University, a system for single user control of an FEL has been designed to satisfy the low voltage FEL (ie 200kV) operational requirements. This system incorporates many aspects of computer automation for beam diagnostics, radiation detection and vacuum system management. In this paper the results of the development of safety critical control systems critical control systems are reported.

  18. Application of Diagnostic/Prognostic Methods to Critical Equipment for the Spent Nuclear Fuel Cleanup Program

    SciTech Connect

    Casazza, Lawrence O.; Jarrell, Donald B.; Koehler, Theresa M.; Meador, Richard J.; Wallace, Dale E.

    2002-02-28

    The management of the Spent Nuclear Fuel (SNF) project at the Hanford K-Basin in the 100 N Area has successfully restructured the preventive maintenance, spare parts inventory requirements, and the operator rounds data requirements. In this investigation, they continue to examine the different facets of the operations and maintenance (O&M) of the K-Basin cleanup project in search of additional reliability and cost savings. This report focuses on the initial findings of a team of PNNL engineers engaged to identify potential opportunities for reducing the cost of O&M through the application of advanced diagnostics (fault determination) and prognostics (residual life/reliability determination). The objective is to introduce predictive technologies to eliminate or reduce high impact equipment failures. The PNNL team in conjunction with the SNF engineers found the following major opportunities for cost reduction and/or enhancing reliability: (1) Provide data routing and automated analysis from existing detection systems to a display center that will engage the operations and engineering team. This display will be operator intuitive with system alarms and integrated diagnostic capability. (2) Change operating methods to reduce major transients induced in critical equipment. This would reduce stress levels on critical equipment. (3) Install a limited sensor set on failure prone critical equipment to allow degradation or stressor levels to be monitored and alarmed. This would provide operators and engineers with advance guidance and warning of failure events. Specific methods for implementation of the above improvement opportunities are provided in the recommendations. They include an Integrated Water Treatment System (IWTS) decision support system, introduction of variable frequency drives on certain pump motors, and the addition of limited diagnostic instrumentation on specified critical equipment.

  19. An Operator Method for Evaluating Laplace Transforms

    ERIC Educational Resources Information Center

    Lanoue, B. G.; Yurekli, O.

    2005-01-01

    This note discusses a simple operator technique based on the differentiation and shifting properties of the Laplace transform to find Laplace transforms for various elementary functions. The method is simpler than known integration techniques to evaluate Laplace transforms.

  20. An Analysis of Inhalation Injury Diagnostic Methods and Patient Outcomes.

    PubMed

    Ching, Jessica A; Ching, Yiu-Hei; Shivers, Steven C; Karlnoski, Rachel A; Payne, Wyatt G; Smith, David J

    2016-01-01

    The purpose of this study was to compare patient outcomes according to the method of diagnosing burn inhalation injury. After approval from the American Burn Association, the National Burn Repository Dataset Version 8.0 was queried for patients with a diagnosis of burn inhalation injury. Subgroups were analyzed by diagnostic method as defined by the National Burn Repository. All diagnostic methods listed for each patient were included, comparing mortality, hospital days, intensive care unit (ICU) days, and ventilator days (VDs). Z-tests, t-tests, and linear regression were used with a statistical significance of P value of less than .05. The database query yielded 9775 patients diagnosed with inhalation injury. The greatest increase in mortality was associated with diagnosis by bronchoscopy or carbon monoxide poisoning. A relative increase in hospital days was noted with diagnosis by bronchoscopy (9 days) or history (2 days). A relative increase in ICU days was associated with diagnosis according to bronchoscopy (8 days), clinical findings (2 days), or history (2 days). A relative increase in VDs was associated with diagnosis by bronchoscopy (6 days) or carbon monoxide poisoning (3 days). The combination of diagnosis by bronchoscopy and clinical findings increased the relative difference across all comparison measures. The combination of diagnosis by bronchoscopy and carbon monoxide poisoning exhibited decreased relative differences when compared with bronchoscopy alone. Diagnosis by laryngoscopy showed no mortality or association with poor outcomes. Bronchoscopic evidence of inhalation injury proved most useful, predicting increased mortality, hospital, ICU, and VDs. A combined diagnosis determined by clinical findings and bronchoscopy should be considered for clinical practice. PMID:26594867

  1. Helicobacter pylori identification: a diagnostic/confirmatory method for evaluation.

    PubMed

    Mesquita, B; Gonçalves, M J; Pacheco, P; Lopes, J; Salazar, F; Relvas, M; Coelho, C; Pacheco, J J; Velazco, C

    2014-09-01

    The Helicobacter pylori extra gastric reservoir is probably the oral cavity. In order to evaluate the presence of this bacterium in patients with periodontitis and suspicious microbial cultures, saliva was collected from these and non-periodontitis subjects. PCRs targeting 16S rRNA gene and a 860 bp specific region were performed, and digested with the restriction enzyme DdeI. We observed that the PCR-RFLP approach augments the accuracy from 26.2 % (16/61), found in the PCR-based results, to 42.6 % (26/61), which is an excellent indicator for the establishment of this low-cost procedure as a diagnostic/confirmatory method for H. pylori evaluation. PMID:24715050

  2. Novel scanner characterization method for color measurement and diagnostics applications

    NASA Astrophysics Data System (ADS)

    Lee, Bong-Sun; Bala, Raja; Sharma, Gaurav

    2006-02-01

    We propose a novel scanner characterization approach for applications requiring color measurement of hardcopy output in printer calibration, characterization, and diagnostic applications. It is assumed that a typical printed medium comprises the three basic colorants C, M, Y. The proposed method is particularly advantageous when additional colorants are used in the print (e.g. black (K)). A family of scanner characterization targets is constructed, each varying in C, M, Y and at a fixed level of K. A corresponding family of 3-D scanner characterizations is derived, one for each level of K. Each characterization maps scanner RGB to a colorimetric representation such as CIELAB, using standard characterization techniques. These are then combined into a single 4-D characterization mapping RGBK to CIELAB. A refinement of the technique improves performance significantly by using a function of the scanned values for K (e.g. the scanner's green channel response to printed K) instead of the digital K value directly. This makes this new approach more robust with respect to variations in printed K over time. Secondly it enables, with a single scanner characterization, accurate color measurement of prints from different printers within the same family. Results show that the 4-D characterization technique can significantly outperform standard 3-D approaches especially in cases where the image being scanned is a patch target made up of unconstrained CMYK combinations. Thus the algorithm finds particular use in printer characterization and diagnostic applications. The method readily generalizes to printed media containing other (e.g "hi-fi") colorants, and also to other image capture devices such as digital cameras.

  3. Diagnostic Methods for Platelet Bacteria Screening: Current Status and Developments

    PubMed Central

    Störmer, Melanie; Vollmer, Tanja

    2014-01-01

    Summary Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes. PMID:24659944

  4. Diagnostic methods to assess inspiratory and expiratory muscle strength*

    PubMed Central

    Caruso, Pedro; de Albuquerque, André Luis Pereira; Santana, Pauliane Vieira; Cardenas, Leticia Zumpano; Ferreira, Jeferson George; Prina, Elena; Trevizan, Patrícia Fernandes; Pereira, Mayra Caleffi; Iamonti, Vinicius; Pletsch, Renata; Macchione, Marcelo Ceneviva; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Impairment of (inspiratory and expiratory) respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation); and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength. PMID:25972965

  5. Vaccines and diagnostic methods for bovine mastitis: fact and fiction.

    PubMed

    Yancey, R J

    1999-01-01

    A number of problems are uniquely associated with vaccination of dairy cows for mastitis. One of these is that the number of mastitis pathogens is numerous and heterogeneous. Vaccine efforts have concentrated mainly on the major mastitis pathogens. While at least one S. aureus bacterin has been commercially available for a number of years, no large-scale, independent field trials have been published in refereed journals which support the efficacy of this vaccine. Experimental vaccines for S. aureus composed of pseudocapsule-enriched bacterins supplemented with alpha- and/or beta-toxoids appear promising, but none of these has been commercialized. With S. uberis, some protection against homologous strain challenges was reported recently with a live strain and a bacterin, but other data from the same laboratory showed this vaccine would not protect against heterologous challenge strains. At this time there is only one highly effective vaccine for mastitis, the core-antigen vaccine for coliform mastitis. All of the commercially available vaccines for this indication are bacterins of rough mutants of E. coli strain J5 or Salmonella spp. Preliminary success with an experimental vaccine based on the plasminogen activator of S. uberis is a very different approach for a mastitis vaccine. Little success has been reported with vaccination against other mastitis pathogens. For diagnostic methods, the high somatic cell count, as measured by direct count or indirect assays, remains the cornerstone of mastitis diagnosis. However, for subclinical mastitis, bacterial cell culture is a reliable diagnostic method. Pathogen identification may rely on older biochemical testing methods or newer commercial identification systems, depending on the laboratory budget. ELISA assays also have been used to assess herd infection status. Epidemiologic studies have used DNA fingerprinting and ribotyping, but none of these methods has yet produced an easily utilized commercial format. Within the

  6. Operational diagnostics of thermal state and efficiency of steam turbines of TPP and NPP

    NASA Astrophysics Data System (ADS)

    Bozhko, V. V.; Kovalenko, A. N.; Lyapunov, V. M.; Khomenok, L. A.

    2016-05-01

    Various ways for solving complex problems of the strength and operating life of steam turbines of TPP and NPP are studied. Diagnostic characters and technical possibilities for their control during the steam turbine operation are determined. It is shown that the effect of various factors on the reliability, maneuverability, and service life of power installations of TPP and NPP is generally determined by the thermal state of steam-electric generating sets. Leading foreign and domestic manufacturers give major attention to the organization of the control of the thermal state of facilities and the development of systems for accounting ("counter") the service life depletion. Zones of high-temperature sites of shafts and disks with maximum parameters of operating environment are determined. A model for on-line computation of thermal stresses with the diagnostic evaluation of the service life depletion (fatigue accumulation) and forecasting of optimum heating conditions for thermostressed turbine units is briefly stated. An example of a program for diagnostics of the quality of the facility operation is given. The program provides the operative control of thermal stresses and the service life depletion in main units of the turbine under various operation conditions, operates in the real-time mode, calculates and represents currents values of thermal stresses in turbine units, and forms and transmits into the industrial control signals on the occurrence of restrictions with respect to thermal stresses and prohibition of an increase or decrease in the vapor temperature and the load in the case of approaching pressures to maximum permissible ones. In the case of stationary operation conditions, the program computed the current efficiency in high (HPC) and mean (MPC) pressure cylinders.

  7. Radiative transfer model: matrix operator method.

    PubMed

    Liu, Q; Ruprecht, E

    1996-07-20

    A radiative transfer model, the matrix operator method, is discussed here. The matrix operator method is applied to a plane-parallel atmosphere within three spectral ranges: the visible, the infrared, and the microwave. For a homogeneous layer with spherical scattering, the radiative transfer equation can be solved analytically. The vertically inhomogeneous atmosphere can be subdivided into a set of homogeneous layers. The solution of the radiative transfer equation for the vertically inhomogeneous atmosphere is obtained recurrently from the analytical solutions for the subdivided layers. As an example for the application of the matrix operator method, the effects of the cirrus and the stratocumulus clouds on the net radiation at the surface and at the top of the atmosphere are investigated. The relationship between the polarization in the microwave range and the rain rates is also studied. Copies of the FORTRAN program and the documentation of the FORTRAN program on a diskette are available. PMID:21102832

  8. Implementation of the {alpha}-CHERS diagnostic for D-T operation of TFTR

    SciTech Connect

    McKee, G.R.; Fonck, R.J.; Stratton, F.K.

    1995-03-01

    The {alpha}-CHERS diagnostic is a high throughput charge exchange recombination spectroscopy diagnostic designed to measure the density profile and time evolution of 0-500 keV alpha particles during D-T operation of TFTR. Following successful tests with a prototype ({alpha}-CHERS system, an improved, multi-channel system has been installed for D-T Operation. Three spatial channels may be observed simultaneously, and the spectral resolution of 0.5 nm permits increased alpha energy resolution and improved impurity line identification. More efficient coupling optics between the spectrometer and CCD detectors have increased the light throughput, and radiation shielding has been installed around the detectors and spectrometers to eliminate the neutron/gamma ray noise observed in high power D-D plasmas.

  9. METHOD OF OPERATING A NEUTRONIC REACTOR

    DOEpatents

    Turkevich, A.

    1963-01-22

    This patent relates to one step in a method of operating a neutronic reactor consisting of a slurry of fissionable material in heavy water. Deuterium gas is passed through the slurry to sweep gaseous fission products therefrom and the deuterium is then separated from the gaseous fission products. (AEC)

  10. Diagnostic Methods for Bile Acid Malabsorption in Clinical Practice

    PubMed Central

    Vijayvargiya, Priya; Camilleri, Michael; Shin, Andrea; Saenger, Amy

    2013-01-01

    Altered bile acid (BA) concentrations in the colon may cause diarrhea or constipation. BA malabsorption (BAM) accounts for >25% of patients with irritable bowel syndrome (IBS) with diarrhea and chronic diarrhea in Western countries. As BAM is increasingly recognized, proper diagnostic methods are desired in clinical practice to help direct the most effective treatment course for the chronic bowel dysfunction. This review appraises the methodology, advantages and disadvantages of 4 tools that directly measure BAM: 14C-glycocholate breath and stool test, 75Selenium HomotauroCholic Acid Test (SeHCAT), 7 α-hydroxy-4-cholesten-3-one (C4) and fecal BAs. 14C-glycocholate is a laborious test no longer widely utilized. 75SeHCAT is validated, but not available in the United States. Serum C4 is a simple, accurate method that is applicable to a majority of patients, but requires further clinical validation. Fecal measurements to quantify total and individual fecal BAs are technically cumbersome and not widely available. Regrettably, none of these tests are routinely available in the U.S., and a therapeutic trial with a BA binder is used as a surrogate for diagnosis of BAM. Recent data suggest there is an advantage to studying fecal excretion of the individual BAs and their role in BAM; this may constitute a significant advantage of the fecal BA method over the other tests. Fecal BA test could become a routine addition to fecal fat measurement in patients with unexplained diarrhea. In summary, availability determines the choice of test among C4, SeHCAT and fecal BA; more widespread availability of such tests would enhance clinical management of these patients. PMID:23644387

  11. Edge Thomson scattering diagnostic on COMPASS tokamak: Installation, calibration, operation, improvements

    SciTech Connect

    Bohm, P. Bilkova, P.; Melich, R.; Sestak, D.; Weinzettl, V.; Stockel, J.; Hron, M.; Panek, R.; Mikulin, O.; Scannell, R.; Naylor, G.; Frassinetti, L.; Fassina, A.; Walsh, M. J.

    2014-11-15

    The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles.

  12. Edge Thomson scattering diagnostic on COMPASS tokamak: installation, calibration, operation, improvements.

    PubMed

    Bohm, P; Aftanas, M; Bilkova, P; Stefanikova, E; Mikulin, O; Melich, R; Janky, F; Havlicek, J; Sestak, D; Weinzettl, V; Stockel, J; Hron, M; Panek, R; Scannell, R; Frassinetti, L; Fassina, A; Naylor, G; Walsh, M J

    2014-11-01

    The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles. PMID:25430338

  13. Dental and dental hygiene students' diagnostic accuracy in oral radiology: effect of diagnostic strategy and instructional method.

    PubMed

    Baghdady, Mariam T; Carnahan, Heather; Lam, Ernest W N; Woods, Nicole N

    2014-09-01

    There has been much debate surrounding diagnostic strategies and the most appropriate training models for novices in oral radiology. It has been argued that an analytic approach, using a step-by-step analysis of the radiographic features of an abnormality, is ideal. Alternative research suggests that novices can successfully employ non-analytic reasoning. Many of these studies do not take instructional methodology into account. This study evaluated the effectiveness of non-analytic and analytic strategies in radiographic interpretation and explored the relationship between instructional methodology and diagnostic strategy. Second-year dental and dental hygiene students were taught four radiographic abnormalities using basic science instructions or a step-by-step algorithm. The students were tested on diagnostic accuracy and memory immediately after learning and one week later. A total of seventy-three students completed both immediate and delayed sessions and were included in the analysis. Students were randomly divided into two instructional conditions: one group provided a diagnostic hypothesis for the image and then identified specific features to support it, while the other group first identified features and then provided a diagnosis. Participants in the diagnosis-first condition (non-analytic reasoning) had higher diagnostic accuracy then those in the features-first condition (analytic reasoning), regardless of their learning condition. No main effect of learning condition or interaction with diagnostic strategy was observed. Educators should be mindful of the potential influence of analytic and non-analytic approaches on the effectiveness of the instructional method. PMID:25179924

  14. Diagnostic Methods for Detection of Blood-Borne Candidiasis.

    PubMed

    Clancy, Cornelius J; Nguyen, M Hong

    2016-01-01

    β-D-glucan (Fungitell) and polymerase chain reaction-based (T2Candida) assays of blood samples are FDA-approved adjuncts to cultures for diagnosing candidemia and other types of invasive candidiasis, but their clinical roles are unclear. In this chapter, we describe laboratory protocols for performing Fungitell and T2Candida assays. We then discuss step-by-step methods for interpreting test results at the bedside using a Bayesian framework, and for incorporating assays into rational patient management strategies. Prior to interpreting results, clinicians must recognize that test performance varies based on the type of invasive candidiasis being diagnosed. In general, the type of invasive candidiasis that is most likely in a given patient can be identified, and the pretest likelihood of disease estimated. From there, positive and negative predictive values (PPV, NPV) for an assay can be calculated. At a population level, tests can be incorporated into screening strategies for antifungal treatment. NPV and PPV thresholds can be defined for discontinuing antifungal prophylaxis or initiating preemptive treatment, respectively. Using the thresholds, it is possible to assign windows of pretest likelihood for invasive candidiasis (and corresponding patient populations) in which tests are most likely to valuable. At the individual patient level, tests may be useful outside of the windows proposed for screening populations. The interpretive and clinical decision-making processes we discuss will be applicable to other diagnostic assays as they enter the clinic, and to existing assays as more data emerge from various populations. PMID:26519076

  15. Optical caries diagnostics: comparison of laser spectroscopic PNC method with method of laser integral fluorescence

    NASA Astrophysics Data System (ADS)

    Masychev, Victor I.

    2000-11-01

    In this research we present the results of approbation of two methods of optical caries diagnostics: PNC-spectral diagnostics and caries detection by laser integral fluorescence. The research was conducted in a dental clinic. PNC-method analyses parameters of probing laser radiation and PNC-spectrums of stimulated secondary radiations: backscattering and endogenous fluorescence of caries-involved bacterias. He-Ne-laser ((lambda) =632,8 nm, 1-2mW) was used as a source of probing (stimulated) radiation. For registration of signals, received from intact and pathological teeth PDA-detector was applied. PNC-spectrums were processed by special algorithms, and were displayed on PC monitor. The method of laser integral fluorescence was used for comparison. In this case integral power of fluorescence of human teeth was measured. As a source of probing (stimulated) radiation diode lasers ((lambda) =655 nm, 0.1 mW and 630nm, 1mW) and He-Ne laser were applied. For registration of signals Si-photodetector was used. Integral power was shown in a digital indicator. Advantages and disadvantages of these methods are described in this research. It is disclosed that the method of laser integral power of fluorescence has the following characteristics: simplicity of construction and schema-technical decisions. However the method of PNC-spectral diagnostics are characterized by considerably more sensitivity in diagnostics of initial caries and capability to differentiate pathologies of various stages (for example, calculus/initial caries). Estimation of spectral characteristics of PNC-signals allows eliminating a number of drawbacks, which are character for detection by method of laser integral fluorescence (for instance, detection of fluorescent fillings, plagues, calculus, discolorations generally, amalgam, gold fillings as if it were caries.

  16. Chronic intraoral pain--assessment of diagnostic methods and prognosis.

    PubMed

    Pigg, Maria

    2011-01-01

    The overall goal of this thesis was to broaden our knowledge of chronic intraoral pain. The research questions were: What methods can be used to differentiate inflammatory, odontogenic tooth pain from pain that presents as toothache but is non-odontogenic in origin? What is the prognosis of chronic tooth pain of non-odontogenic origin, and which factors affect the prognosis? Atypical odontalgia (AO) is a relatively rare but severe and chronic pain condition affecting the dentoalveolar region. Recent research indicates that the origin is peripheral nerve damage: neuropathic pain. The condition presents as tooth pain and is challenging to dentists because it is difficult to distinguish from ordinary toothache due to inflammation or infection. AO is of interest to the pain community because it shares many characteristics with other chronic pain conditions, and pain perpetuation mechanisms are likely to be similar. An AO diagnosis is made after a comprehensive examination and assessment of patients' self-reported characteristics: the pain history. Traditional dental diagnostic methods do not appear to suffice, since many patients report repeated care-seeking and numerous treatment efforts with little or no pain relief. Developing methods that are useful in the clinical setting is a prerequisite for a correct diagnosis and adequate treatment decisions. Quantitative sensory testing (QST) is used to assess sensory function on skin when nerve damage or disease is suspected. A variety of stimuli has been used to examine the perception of, for example, touch, temperature (painful and non-painful), vibration, pinprick pain, and pressure pain. To detect sensory abnormalities and nerve damage in the oral cavity, the same methods may be possible to use. Study I examined properties of thermal thresholds in and around the mouth in 30 pain-free subjects: the influence of measurement location and stimulation area size on threshold levels, and time variability of thresholds

  17. Method of evaluating subsurface fracturing operations

    SciTech Connect

    Soliman, M.Y.

    1989-06-06

    This patent describes a method of determining parameters of a subsurface operation fracturing an earth formation, comprising: fracturing the formation with a fracturing fluid; determining a first pressure decline value representative of the observed pressure decline of the fractured formation over a time interval. The first pressure decline value functionally related to the properties of the fracturing fluid during the fracturing of the formation; determining a second pressure decline value representative of the pressure decline which should have been observed if the fracturing fluid was incompressible; and determining the parameters of the fracturing operation in response to the pressure decline value.

  18. Advanced Optical Diagnostic Methods for Describing Fuel Injection and Combustion Flowfield Phenomena

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.

    2004-01-01

    Over the past decade advanced optical diagnostic techniques have evolved and matured to a point where they are now widely applied in the interrogation of high pressure combusting flows. At NASA Glenn Research Center (GRC), imaging techniques have been used successfully in on-going work to develop the next generation of commercial aircraft gas turbine combustors. This work has centered on providing a means by which researchers and designers can obtain direct visual observation and measurements of the fuel injection/mixing/combustion processes and combustor flowfield in two- and three-dimensional views at actual operational conditions. Obtaining a thorough understanding of the chemical and physical processes at the extreme operating conditions of the next generation of combustors is critical to reducing emissions and increasing fuel efficiency. To accomplish this and other tasks, the diagnostic team at GRC has designed and constructed optically accessible, high pressurer high temperature flame tubes and sectar rigs capable of optically probing the 20-60 atm flowfields of these aero-combustors. Among the techniques employed at GRC are planar laser-induced fluorescence (PLIF) for imaging molecular species as well as liquid and gaseous fuel; planar light scattering (PLS) for imaging fuel sprays and droplets; and spontaneous Raman scattering for species and temperature measurement. Using these techniques, optical measurements never before possible have been made in the actual environments of liquid fueled gas turbines. 2-D mapping of such parameters as species (e.g. OH-, NO and kerosene-based jet fuel) distribution, injector spray angle, and fuel/air distribution are just some of the measurements that are now routinely made. Optical imaging has also provided prompt feedback to researchers regarding the effects of changes in the fuel injector configuration on both combustor performance and flowfield character. Several injector design modifications and improvements have

  19. Exploring medical diagnostic performance using interactive, multi-parameter sourced receiver operating characteristic scatter plots.

    PubMed

    Moore, Hyatt E; Andlauer, Olivier; Simon, Noah; Mignot, Emmanuel

    2014-04-01

    Determining diagnostic criteria for specific disorders is often a tedious task that involves determining optimal diagnostic thresholds for symptoms and biomarkers using receiver-operating characteristic (ROC) statistics. To help this endeavor, we developed softROC, a user-friendly graphic-based tool that lets users visually explore possible ROC tradeoffs. The software requires MATLAB installation and an Excel file containing threshold symptoms/biological measures, with corresponding gold standard diagnoses for a set of patients. The software scans the input file for diagnostic and symptom/biomarkers columns, and populates the graphical-user-interface (GUI). Users select symptoms/biomarkers of interest using Boolean algebra as potential inputs to create diagnostic criteria outputs. The software evaluates subtests across the user-established range of cut-points and compares them to a gold standard in order to generate ROC and quality ROC scatter plots. These plots can be examined interactively to find optimal cut-points of interest for a given application (e.g. sensitivity versus specificity needs). Split-set validation can also be used to set up criteria and validate these in independent samples. Bootstrapping is used to produce confidence intervals. Additional statistics and measures are provided, such as the area under the ROC curve (AUC). As a testing set, softROC is used to investigate nocturnal polysomnogram measures as diagnostic features for narcolepsy. All measures can be outputted to a text file for offline analysis. The softROC toolbox, with clinical training data and tutorial instruction manual, is provided as supplementary material and can be obtained online at http://www.stanford.edu/~hyatt4/software/softroc or from the open source repository at http://www.github.com/informaton/softroc. PMID:24561350

  20. FTDD973: A multimedia knowledge-based system and methodology for operator training and diagnostics

    NASA Technical Reports Server (NTRS)

    Hekmatpour, Amir; Brown, Gary; Brault, Randy; Bowen, Greg

    1993-01-01

    FTDD973 (973 Fabricator Training, Documentation, and Diagnostics) is an interactive multimedia knowledge based system and methodology for computer-aided training and certification of operators, as well as tool and process diagnostics in IBM's CMOS SGP fabrication line (building 973). FTDD973 is an example of what can be achieved with modern multimedia workstations. Knowledge-based systems, hypertext, hypergraphics, high resolution images, audio, motion video, and animation are technologies that in synergy can be far more useful than each by itself. FTDD973's modular and object-oriented architecture is also an example of how improvements in software engineering are finally making it possible to combine many software modules into one application. FTDD973 is developed in ExperMedia/2; and OS/2 multimedia expert system shell for domain experts.

  1. Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

    SciTech Connect

    Koenig, R.; Cantarini, J.; Dreier, H.; Erckmann, V.; Hildebrandt, D.; Hirsch, M.; Kornejew, P.; Laux, M.; Laqua, H.; Pasch, E.; Thomsen, H.; Weller, A.; Werner, A.; Wolf, R.; Ye, M. Y.; Kocsis, G.; Recsei, S.; Zoletnik, S.; Szabo, V.

    2008-10-15

    The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m{sup 2} from radiation alone and of up to about 500 kW/m{sup 2} on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m{sup 2} need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

  2. Molecular IR Spectroscopy: New Trends and Methods of Noninvasive Diagnostics of Tissue IN VIVO

    NASA Astrophysics Data System (ADS)

    Afanasyeva, Natalia; Bruch, Reinhard

    1998-05-01

    Fiberoptic evanescent wave Fourier transform infrared (FEW-FTIR) spectroscopy using fiberoptic sensors operated in the attenuated total reflection (ATR) regime in the middle infrared (IR) region of the spectrum (850-1850 cm-1) has recently been applied to the diagnostics of tissues. The method is suitable for noninvasive and rapid (seconds) direct measurements of the spectra of normal and pathological tissues in vitro, ex vivo and in vivo. The aim of our studies is the express testing of various tumor tissues at the early stages of their development. The method is expected to be further developed for endoscopic and biopsy applications. We measured the normal skin and malignant tissues in vivo on the surface (directly on patients) in various cases of basaloma, melanoma and nevus. The experiments were performed in the operating room to measure the skin in the depth (under/in the layers of epidermis) of human breast, stomach, lung, and kidney tissues. The breast and skin tissues at different stages of tumor or cancer were distinguished very clearly in spectra of amide, side cyclic and noncyclic hydrogen bonded fragments of aminoacid residuals, phosphate groups and sugars. Computer monitoring is being developed for diagnostics.

  3. Engine and method for operating an engine

    DOEpatents

    Lauper, Jr., John Christian; Willi, Martin Leo; Thirunavukarasu, Balamurugesh; Gong, Weidong

    2008-12-23

    A method of operating an engine is provided. The method may include supplying a combustible combination of reactants to a combustion chamber of the engine, which may include supplying a first hydrocarbon fuel, hydrogen fuel, and a second hydrocarbon fuel to the combustion chamber. Supplying the second hydrocarbon fuel to the combustion chamber may include at least one of supplying at least a portion of the second hydrocarbon fuel from an outlet port that discharges into an intake system of the engine and supplying at least a portion of the second hydrocarbon fuel from an outlet port that discharges into the combustion chamber. Additionally, the method may include combusting the combustible combination of reactants in the combustion chamber.

  4. Electrically heated particulate filter diagnostic systems and methods

    DOEpatents

    Gonze, Eugene V [Pinckney, MI

    2009-09-29

    A system that diagnoses regeneration of an electrically heated particulate filter is provided. The system generally includes a grid module that diagnoses a fault of the grid based on at least one of a current signal and a voltage signal. A diagnostic module at least one of sets a fault status and generates a warning signal based on the fault of the grid.

  5. Sherlock Holmes' methods of deductive reasoning applied to medical diagnostics.

    PubMed

    Miller, L

    1985-03-01

    Having patterned the character of Sherlock Holmes after one of his professors, Sir Arthur Conan Doyle, himself a physician, incorporated many of the didactic qualities of the 19th century medical diagnostician into the character of Holmes. In this paper I explore Holmes's techniques of deductive reasoning and their basis in 19th and 20th century medical diagnostics. PMID:3887762

  6. Sherlock Holmes's Methods of Deductive Reasoning Applied to Medical Diagnostics

    PubMed Central

    Miller, Larry

    1985-01-01

    Having patterned the character of Sherlock Holmes after one of his professors, Sir Arthur Conan Doyle, himself a physician, incorporated many of the didactic qualities of the 19th century medical diagnostician into the character of Holmes. In this paper I explore Holmes's techniques of deductive reasoning and their basis in 19th and 20th century medical diagnostics. PMID:3887762

  7. Comparison of Self-Instruction Methods for Teaching Diagnostic Testing.

    ERIC Educational Resources Information Center

    Puskas, Jane C.

    1991-01-01

    Self-teaching booklets and computer media were evaluated for teaching diagnostic testing with first (n=49), second (n=41) and third year (n=71) dental students as a foundation for further development of clinical decision-making skills. Results found the media more effective than no instruction and equally effective to the traditional lecture…

  8. First operations with the new Collective Thomson Scattering diagnostic on the Frascati Tokamak Upgrade device

    NASA Astrophysics Data System (ADS)

    Bin, W.; Bruschi, A.; D'Arcangelo, O.; Castaldo, C.; De Angeli, M.; Figini, L.; Galperti, C.; Garavaglia, S.; Granucci, G.; Grosso, G.; Korsholm, S. B.; Lontano, M.; Mellera, V.; Minelli, D.; Moro, A.; Nardone, A.; Nielsen, S. K.; Rasmussen, J.; Simonetto, A.; Stejner, M.; Tartari, U.

    2015-10-01

    Anomalous emissions were found over the last few years in spectra of Collective Thomson Scattering (CTS) diagnostics in tokamak devices such as TEXTOR, ASDEX and FTU, in addition to real CTS signals. The signal frequency, down-shifted with respect to the probing one, suggested a possible origin in Parametric Decay Instability (PDI) processes correlated with the presence of magnetic islands and occurring for pumping wave power levels well below the threshold predicted by conventional models. A threshold below or close to the Electron Cyclotron Resonance Heating (ECRH) power levels could limit, under certain circumstances, the use of the ECRH in fusion devices. An accurate characterization of the conditions for the occurrence of this phenomenon and of its consequences is thus of primary importance. Exploiting the front-steering configuration available with the real-time launcher, the implementation of a new CTS setup now allows studying these anomalous emission phenomena in FTU under conditions of density and wave injection geometry that are more similar to those envisaged for CTS in ITER. The upgrades of the diagnostic are presented as well as a few preliminary spectra detected with the new system during the very first operations in 2014. The present work has been carried out under an EUROfusion Enabling Research project. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  9. Impact of gene patents on diagnostic testing: a new patent landscaping method applied to spinocerebellar ataxia

    PubMed Central

    Berthels, Nele; Matthijs, Gert; Van Overwalle, Geertrui

    2011-01-01

    Recent reports in Europe and the United States raise concern about the potential negative impact of gene patents on the freedom to operate of diagnosticians and on the access of patients to genetic diagnostic services. Patents, historically seen as legal instruments to trigger innovation, could cause undesired side effects in the public health domain. Clear empirical evidence on the alleged hindering effect of gene patents is still scarce. We therefore developed a patent categorization method to determine which gene patents could indeed be problematic. The method is applied to patents relevant for genetic testing of spinocerebellar ataxia (SCA). The SCA test is probably the most widely used DNA test in (adult) neurology, as well as one of the most challenging due to the heterogeneity of the disease. Typically tested as a gene panel covering the five common SCA subtypes, we show that the patenting of SCA genes and testing methods and the associated licensing conditions could have far-reaching consequences on legitimate access to this gene panel. Moreover, with genetic testing being increasingly standardized, simply ignoring patents is unlikely to hold out indefinitely. This paper aims to differentiate among so-called ‘gene patents' by lifting out the truly problematic ones. In doing so, awareness is raised among all stakeholders in the genetic diagnostics field who are not necessarily familiar with the ins and outs of patenting and licensing. PMID:21811306

  10. Evaluating Operational Specifications of Point-of-Care Diagnostic Tests: A Standardized Scorecard

    PubMed Central

    Lehe, Jonathan D.; Sitoe, Nádia E.; Tobaiwa, Ocean; Loquiha, Osvaldo; Quevedo, Jorge I.; Peter, Trevor F.; Jani, Ilesh V.

    2012-01-01

    The expansion of HIV antiretroviral therapy into decentralized rural settings will increasingly require simple point-of-care (POC) diagnostic tests that can be used without laboratory infrastructure and technical skills. New POC test devices are becoming available but decisions around which technologies to deploy may be biased without systematic assessment of their suitability for decentralized healthcare settings. To address this, we developed a standardized, quantitative scorecard tool to objectively evaluate the operational characteristics of POC diagnostic devices. The tool scores devices on a scale of 1–5 across 30 weighted characteristics such as ease of use, quality control, electrical requirements, shelf life, portability, cost and service, and provides a cumulative score that ranks products against a set of ideal POC characteristics. The scorecard was tested on 19 devices for POC CD4 T-lymphocyte cell counting, clinical chemistry or hematology testing. Single and multi-parameter devices were assessed in each of test categories. The scores across all devices ranged from 2.78 to 4.40 out of 5. The tool effectively ranked devices within each category (p<0.01) except the CD4 and multi-parameter hematology products. The tool also enabled comparison of different characteristics between products. Agreement across the four scorers for each product was high (intra-class correlation >0.80; p<0.001). Use of this tool enables the systematic evaluation of diagnostic tests to facilitate product selection and investment in appropriate technology. It is particularly relevant for countries and testing programs considering the adoption of new POC diagnostic tests. PMID:23118871

  11. Multiple frequency method for operating electrochemical sensors

    SciTech Connect

    Martin, Louis P.

    2012-05-15

    A multiple frequency method for the operation of a sensor to measure a parameter of interest using calibration information including the steps of exciting the sensor at a first frequency providing a first sensor response, exciting the sensor at a second frequency providing a second sensor response, using the second sensor response at the second frequency and the calibration information to produce a calculated concentration of the interfering parameters, using the first sensor response at the first frequency, the calculated concentration of the interfering parameters, and the calibration information to measure the parameter of interest.

  12. [Fractures of the proximal interphalangeal joint: Diagnostic and operative therapy options].

    PubMed

    Unglaub, F; Langer, M F; Hahn, P; Müller, L P; Ahrens, C; Spies, C K

    2016-02-01

    Joint fractures of the fingers often entail operative interventions in contrast to extra-articular fractures. These types of fracture are inclined to dislocate in addition to the actual fracture. The proximal interphalangeal (PIP) joint in particular often shows comminuted fractures due to the long leverage of the finger and a relatively small diameter of the joint. The clinical examination, X-ray diagnostics and if necessary computed tomography allow the classification into stable and unstable fractures. Unstable fractures must be treated by surgical reduction and fixation. A multitude of operative techniques are available for these mostly complicated fractures. The foremost goal is a stable osteosynthesis of the fracture with repositioning of the dislocation, which enables early physiotherapy in order to prevent tendon adhesion and contracture. This article presents the different types of PIP joint fractures, their specific surgical treatment and postoperative treatment regimens. PMID:26826026

  13. Operation of a multiple cell array detector in plasma experiments with a heavy ion beam diagnostic

    SciTech Connect

    Goncalves, B.; Malaquias, A.; Nedzelskiy, I. S.; Pereira, L.; Silva, C.; Varandas, C.A.F.; Cabral, J.A.C.; Khrebtov, S.M.; Dreval, N.B.; Krupnik, L.I.; Hidalgo, C.; Depablos, J.

    2004-10-01

    A multiple cell array detector (MCAD) has been developed to investigate the spatial structure of plasma turbulence in fusion plasmas. This system is expected to provide simultaneous measurements of edge and core density fluctuations with both temporal and spatial resolution, extending the range and number of the sample volumes simultaneously recorded by a heavy ion beam diagnostic (HIBD). Since the detector (usually located close to the vessel wall of a plasma device) operates in a strong plasma radiation environment, the effective shielding of the detector presents a special problem. This article describes and compares the MCAD operation conditions on ISTTOK tokamak and TJ-II stellarator. Experimental results of the detector performance are presented together with the first measurements of n{sub e}{sigma}{sub eff} in the TJ-II plasmas.

  14. Post-operative cognitive dysfunction after knee arthroplasty: a diagnostic dilemma

    PubMed Central

    Yap, Kiryu K.; Joyner, Peter

    2014-01-01

    Post-operative cognitive dysfunction (POCD) is common in the elderly, and significantly impacts their recovery. We present an unusual diagnostic challenge where a 65-year-old male presented 4-week post-total knee arthroplasty with acute cognitive dysfunction lasting 19 days. Curiously, there were no findings uncovering a specific cause, but during investigation underlying predisposing factors such as depression, mild memory deficits and generalized brain volume loss were identified. The impression after psychogeriatric review was that of an organic brain syndrome with overlay of depression, with a complex presentation as POCD. After escalation of behavioural disturbance, he was commenced on anti-psychotic/depressant, with immediate response. We emphasize the importance of pre-operative evaluation of cognitive function and risk factors in all geriatric patients undergoing elective surgery, and the need for further characterization of POCD, as well as experimental research elucidating the underlying mechanisms to better identify and treat this important post-surgical phenomenon. PMID:25988029

  15. Post-operative cognitive dysfunction after knee arthroplasty: a diagnostic dilemma.

    PubMed

    Yap, Kiryu K; Joyner, Peter

    2014-06-01

    Post-operative cognitive dysfunction (POCD) is common in the elderly, and significantly impacts their recovery. We present an unusual diagnostic challenge where a 65-year-old male presented 4-week post-total knee arthroplasty with acute cognitive dysfunction lasting 19 days. Curiously, there were no findings uncovering a specific cause, but during investigation underlying predisposing factors such as depression, mild memory deficits and generalized brain volume loss were identified. The impression after psychogeriatric review was that of an organic brain syndrome with overlay of depression, with a complex presentation as POCD. After escalation of behavioural disturbance, he was commenced on anti-psychotic/depressant, with immediate response. We emphasize the importance of pre-operative evaluation of cognitive function and risk factors in all geriatric patients undergoing elective surgery, and the need for further characterization of POCD, as well as experimental research elucidating the underlying mechanisms to better identify and treat this important post-surgical phenomenon. PMID:25988029

  16. [Survey of studies on adjuvant diagnostic method of stimulating auricular points at home and abroad].

    PubMed

    Chen, Gong-Sun; Hu, Zhi-Hui; Zhu, Bing

    2007-12-01

    The auricular (including auricular acupoints) adjuvant diagnostic method, besides inspection (including dyeing method), palpation (including thermometric method), tenderness method (including impressing method) and electrical detection, includes the adjuvant diagnostic method of stimulating auricular points as well, it has been mostly studied and used by specialists of western medicine or doctors of integrated Chinese and western medicine. But it hasn't been introduced in the published Chinese monographs of auricular acupuncture yet. This article briefly introduces the adjuvant diagnostic method of stimulating auricular points combined with X-ray radiography; application in fetal heart electronic monitoring and fetal biophysical monitoring; and diagnostic methods of auricle reflex, vascular autonomous signals, and auricle and somatic 7 frequency response regions, which began to be researched abroad 35 years ago. The authors hope it will give some invigoration or illumination to my colleagues in acupuncture, especially those who are interested in auricular acupuncture. PMID:18271243

  17. In Depth Diagnostics for RF System Operation in the PEP-II B Factory

    SciTech Connect

    Van Winkle, Daniel; Fox, John; Teytelman, Dmitry; /SLAC

    2005-05-27

    The PEP-II RF systems incorporate numerous feedback loops in the low-level processing for impedance control and operating point regulation. The interaction of the multiple loops with the beam is complicated, and the systems incorporate online diagnostic tools to configure the feedback loops as well as to record fault files in the case of an RF abort. Rapid and consistent analysis of the RF-related beam aborts and other failures is critical to the reliable operation of the B-Factory, especially at the recently achieved high beam currents. Procedures and algorithms used to extract diagnostic information from time domain fault files are presented and illustrated via example interpretations of PEP-II fault file data. Example faults presented will highlight the subtle interpretation required to determine the root cause. Some such examples are: abort kicker firing asynchronously, klystron and cavity arcs, beam loss leading to longitudinal instability, tuner read back jumps and poorly configured low-level RF feedback loop.

  18. Speckle methods for diagnostics of the human oral cavity

    NASA Astrophysics Data System (ADS)

    Kharish, Natalia A.; Sedykh, Alexey V.; Ulyanov, Sergey S.; Lepilin, Alexander V.; Tuchin, Valery V.

    1999-11-01

    Possibility of application of speckle interferometry for diagnostics in dentistry has been analyzed. Problem of standardization of the measuring procedure has been studied. Deviation of output characteristics of Doppler system for blood microcirculation measurements has been investigated. Dependence of form of Doppler spectrum on the degree of seriousness of diseases has been studied in experiments in vivo. Behavior of spectral moments of measuring signal during the treatment of parodontitis has been analyzed.

  19. In-situ diagnostic tools for hydrogen transfer leak characterization in PEM fuel cell stacks part II: Operational applications

    NASA Astrophysics Data System (ADS)

    Niroumand, Amir M.; Homayouni, Hooman; DeVaal, Jake; Golnaraghi, Farid; Kjeang, Erik

    2016-08-01

    This paper describes a diagnostic tool for in-situ characterization of the rate and distribution of hydrogen transfer leaks in Polymer Electrolyte Membrane (PEM) fuel cell stacks. The method is based on reducing the air flow rate from a high to low value at a fixed current, while maintaining an anode overpressure. At high air flow rates, the reduction in air flow results in lower oxygen concentration in the cathode and therefore reduction in cell voltages. Once the air flow rate in each cell reaches a low value at which the cell oxygen-starves, the voltage of the corresponding cell drops to zero. However, oxygen starvation results from two processes: 1) the electrochemical oxygen reduction reaction which produces current; and 2) the chemical reaction between oxygen and the crossed over hydrogen. In this work, a diagnostic technique has been developed that accounts for the effect of the electrochemical reaction on cell voltage to identify the hydrogen leak rate and number of leaky cells in a fuel cell stack. This technique is suitable for leak characterization during fuel cell operation, as it only requires stack air flow and voltage measurements, which are readily available in an operational fuel cell system.

  20. First hydrogen operation of NIO1: Characterization of the source plasma by means of an optical emission spectroscopy diagnostic.

    PubMed

    Barbisan, M; Baltador, C; Zaniol, B; Cavenago, M; Fantz, U; Pasqualotto, R; Serianni, G; Vialetto, L; Wünderlich, D

    2016-02-01

    NIO1 (Negative Ion Optimization 1) is a compact and flexible radio frequency H(-) ion source, developed by Consorzio RFX and INFN-LNL. The aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances, an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study, respectively, the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular, the sudden increase of the light emitted from the plasma above a certain power threshold. PMID:26932047

  1. [THE METHODICAL APPROACHES TO DIAGNOSTIC OF NIGHT PAROXYSMAL HEMOGLOBINURIA].

    PubMed

    Plekhanova, O S; Naumova, E V; Lugovskaya, S A; Potchtar, M E; Bugrov, I Yu; Dolgov, V V

    2016-03-01

    The article presents diagnostic of night paroxysmal hemoglobinuria. The night paroxysmal hemoglobinuria is an orphan disease characterized by absence of GPI-anchor on blood cells as a result of mutation of PIG-A gene on the short arm of X-chromosome. The particular proteins bounded with GPI-anchor implement function of defense from activation of components of complement and development of membrane-attacking complex. The erythrocytes exposed to destruction in bloodstream are among the most impacted. Therefore, one of the main signs of night paroxysmal hemoglobinuria is complement-depending intravascular hemolysis which indicators for a long time played a key role in diagnostic of night paroxysmal hemoglobinuria. The actual technique of diagnostic of night paroxysmal hemoglobinuria is flow cytometry. The analysis of night paroxysmal hemoglobinuria clone is recommended to patients with hemolysis of unclear genesis, thrombosis of cerebral and abdominal veins, thrombocytopenia and macrocytosis and also patients with AA, myelodysplastic syndrome, myelofibrosis. The international protocol recommended by the International Society of Clinical Cytometry (2010) is implemented to diagnose night paroxysmal hemoglobinuria. The original technique of evaluation of reticulocytes was developed with purpose to detect night paroxysmal hemoglobinuria clone. The high correlation was substantiated between size of night paroxysmal hemoglobinuria clone measured among reticulocytes according to proposed mode and night paroxysmal hemoglobinuria clone measured among granulocytes and monocytes detected according international standardized approach. PMID:27506106

  2. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    PubMed

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. PMID:26098046

  3. Diagnostic methods for invasive fungal diseases in patients with hematologic malignancies

    PubMed Central

    Riwes, Mary Mansour; Wingard, John R

    2013-01-01

    Invasive fungal disease is associated with increased morbidity and mortality in hematologic malignancy patients and hematopoietic stem cell transplant recipients. Timely recognition and treatment of invasive fungal diseases in these patients are essential and decrease mortality. However, conventional definitive diagnostic methods are difficult and time consuming. While conventional microbiological and histopathological methods are still needed for a definitive diagnosis of invasive fungal disease, new noninvasive diagnostic methods including serologic and molecular biomarkers are now available. These new diagnostic methods facilitate an early diagnosis of invasive fungal disease and allow for utilization of a pre-emptive treatment approach, which may ultimately lead to improved treatment outcomes and reduced toxicity. PMID:23216596

  4. An objective method and measuring equipment for noise control and acoustic diagnostics of motorcars. [acoustic diagnostics on automobile engines

    NASA Technical Reports Server (NTRS)

    Kacprowski, J.; Motylewski, J.; Miazga, J.

    1974-01-01

    An objective method and apparatus for noise control and acoustic diagnostics of motorcar engines are reported. The method and apparatus let us know whether the noisiness of the vehicle under test exceeds the admissible threshold levels given by appropriate standards and if so what is the main source of the excessive noise. The method consists in measuring both the overall noise level and the sound pressure levels in definite frequency bands while the engine speed is controlled as well and may be fixed at prescribed values. Whenever the individually adjusted threshold level has been exceeded in any frequency band, a self-sustaining control signal is sent.

  5. Jet Noise Diagnostics Supporting Statistical Noise Prediction Methods

    NASA Technical Reports Server (NTRS)

    Bridges, James E.

    2006-01-01

    The primary focus of my presentation is the development of the jet noise prediction code JeNo with most examples coming from the experimental work that drove the theoretical development and validation. JeNo is a statistical jet noise prediction code, based upon the Lilley acoustic analogy. Our approach uses time-average 2-D or 3-D mean and turbulent statistics of the flow as input. The output is source distributions and spectral directivity. NASA has been investing in development of statistical jet noise prediction tools because these seem to fit the middle ground that allows enough flexibility and fidelity for jet noise source diagnostics while having reasonable computational requirements. These tools rely on Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) solutions as input for computing far-field spectral directivity using an acoustic analogy. There are many ways acoustic analogies can be created, each with a series of assumptions and models, many often taken unknowingly. And the resulting prediction can be easily reverse-engineered by altering the models contained within. However, only an approach which is mathematically sound, with assumptions validated and modeled quantities checked against direct measurement will give consistently correct answers. Many quantities are modeled in acoustic analogies precisely because they have been impossible to measure or calculate, making this requirement a difficult task. The NASA team has spent considerable effort identifying all the assumptions and models used to take the Navier-Stokes equations to the point of a statistical calculation via an acoustic analogy very similar to that proposed by Lilley. Assumptions have been identified and experiments have been developed to test these assumptions. In some cases this has resulted in assumptions being changed. Beginning with the CFD used as input to the acoustic analogy, models for turbulence closure used in RANS CFD codes have been explored and

  6. Diagnostic and therapeutic single-operator cholangiopancreatoscopy in biliopancreatic diseases: Prospective multicenter study in Japan

    PubMed Central

    Kurihara, Toshio; Yasuda, Ichiro; Isayama, Hiroyuki; Tsuyuguchi, Toshio; Yamaguchi, Taketo; Kawabe, Ken; Okabe, Yoshinobu; Hanada, Keiji; Hayashi, Tsuyoshi; Ohtsuka, Takao; Oana, Syuhei; Kawakami, Hiroshi; Igarashi, Yoshinori; Matsumoto, Kazuya; Tamada, Kiichi; Ryozawa, Shomei; Kawashima, Hiroki; Okamoto, Yutaka; Maetani, Iruru; Inoue, Hiroyuki; Itoi, Takao

    2016-01-01

    AIM: To assess the utility and safety of single-operator cholangiopancreatoscopy (SOCPS) using the SpyGlass system in widespread clinical application for biliary and pancreatic diseases. METHODS: This study was a prospective case series conducted in 20 referral centers in Japan. There were 148 patients who underwent SOCPS; 124 for biliary diseases and 24 for pancreatic diseases. The attempted interventions were SOCPS examination, SOCPS-directed tissue sampling, and therapy for stone removal, among others. The main outcomes were related to the procedure success rate in terms of visualizing the target lesions, SOCPS-directed adequate tissue sampling, and complete stone removal. RESULTS: A total of 148 patients were enrolled for the diagnosis of indeterminate biliary and pancreatic lesions or treatment of biliary and pancreatic disease. The overall procedure success rate of visualizing the target lesions was 91.2% (135/148). The overall procedural success rates of visualizing the target lesions of diagnostic SOCPS in the bile duct and pancreatic duct were 95.5% (84/89) and 88.2% (15/17), respectively. Diagnosis: the overall adequate tissue for histologic examination was secured in 81.4% of the 86 patients who underwent biopsy under SOCPS (bile duct, 60/75, 80.0%; pancreatic duct, 10/11, 90.9%). The accuracy of histologic diagnosis using SOCPS-directed biopsies in indeterminate bile duct lesions was 70.7% (53/75). In the pancreatic duct, the accuracy of SOCPS visual impression of intraductal papillary mucinous neoplasm was 87.5% (14/16). Stone therapy: complete biliary and pancreatic stone clearance combined with SOCPS-directed stone therapy using electrohydraulic lithotripsy or laser lithotripsy was achieved in 74.2% (23/31) and 42.9% (3/7) of the patients, respectively. Others: SOCPS using the SpyGlass system was used in cannulation of the cystic duct in two patients and for passing across the obstructed self-expandable metallic stent for a malignant biliary

  7. Surveillance system and method having an operating mode partitioned fault classification model

    NASA Technical Reports Server (NTRS)

    Bickford, Randall L. (Inventor)

    2005-01-01

    A system and method which partitions a parameter estimation model, a fault detection model, and a fault classification model for a process surveillance scheme into two or more coordinated submodels together providing improved diagnostic decision making for at least one determined operating mode of an asset.

  8. The Revised Research Diagnostic Criteria for Temporomandibular Disorders: Methods used to Establish and Validate Revised Axis I Diagnostic Algorithms

    PubMed Central

    Schiffman, Eric L.; Ohrbach, Richard; Truelove, Edmond L.; Feng, Tai; Anderson, Gary C.; Pan, Wei; Gonzalez, Yoly M.; John, Mike T.; Sommers, Earl; List, Thomas; Velly, Ana M.; Kang, Wenjun; Look, John O.

    2011-01-01

    AIMS To derive reliable and valid revised Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms for clinical TMD diagnoses. METHODS The multi-site RDC/TMD Validation Project’s dataset (614 TMD community and clinic cases, and 91 controls) was used to derive revised algorithms for Axis I TMD diagnoses. Validity of diagnostic algorithms was assessed relative to reference standards, the latter based on consensus diagnoses rendered by 2 TMD experts using criterion examination data, including temporomandibular joint imaging. Cut-offs for target validity were sensitivity ≥ 0.70 and specificity ≥ 0.95. Reliability of revised algorithms was assessed in 27 study participants. RESULTS Revised algorithm sensitivity and specificity exceeded the target levels for myofascial pain (0.82, 0.99, respectively) and myofascial pain with limited opening (0.93, 0.97). Combining diagnoses for any myofascial pain showed sensitivity of 0.91 and specificity of 1.00. For joint pain, target sensitivity and specificity were observed (0.92, 0.96) when arthralgia and osteoarthritis were combined as “any joint pain.” Disc displacement without reduction with limited opening demonstrated target sensitivity and specificity (0.80, 0.97). For the other Group II disc displacements and Group III osteoarthritis and osteoarthrosis, sensitivity was below target (0.35 to 0.53), and specificity ranged from 0.80 to meeting target. Kappa for revised algorithm diagnostic reliability was ≥ 0.63. CONCLUSION Revised RDC/TMD Axis I TMD diagnostic algorithms are recommended for myofascial pain and joint pain as reliable and valid. However, revised clinical criteria alone, without recourse to imaging, are inadequate for valid diagnosis of two of the three disc displacements and osteoarthritis/osteoarthrosis. PMID:20213032

  9. Systematic Review and Meta-Analysis of Studies Evaluating Diagnostic Test Accuracy: A Practical Review for Clinical Researchers-Part II. Statistical Methods of Meta-Analysis.

    PubMed

    Lee, Juneyoung; Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi; Park, Seong Ho

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies. PMID:26576107

  10. Method of operating a coal gasifier

    DOEpatents

    Blaskowski, Henry J.

    1979-01-01

    A method of operating an entrained flow coal gasifier which comprises the steps of firing coal at two levels in a combustion zone with near stoichiometric air, removing molten ash from the combustion zone, conveying combustion products upwardly from the combustion zone through a reduction zone, injecting additional coal into the combustion products in the reduction zone and gasifying at least a portion of the coal to form low BTU gas, conveying the gas to a point of use, including also reducing gasifier output by modifying the ratio of air to coal supplied to the upper level of the combustion zone so that the ratio becomes increasingly substoichiometric thereby extending the gasification of coal from the reduction zone into the upper level of the combustion zone, and maintaining the lower level of coal in the combustion zone at near stoichiometric conditions so as to provide sufficient heat to maintain effective slagging conditions.

  11. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    SciTech Connect

    Corey, J.P.; Liudahl, J.J.; Young, S.A.; Rodman, S.M. )

    1991-03-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician.

  12. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid

  13. Non-Intrusive Optical Diagnostic Methods for Flowfield Characterization

    NASA Technical Reports Server (NTRS)

    Tabibi, Bagher M.; Terrell, Charles A.; Spraggins, Darrell; Lee, Ja. H.; Weinstein, Leonard M.

    1997-01-01

    Non-intrusive optical diagnostic techniques such as Electron Beam Fluorescence (EBF), Laser-Induced Fluorescence (LIF), and Focusing Schlieren (FS) have been setup for high-speed flow characterization and large flowfield visualization, respectively. Fluorescence emission from the First Negative band of N2(+) with the (0,0) vibration transition (at lambda =391.44 nm) was obtained using the EBF technique and a quenching rate of N2(+)* molecules by argon gas was reported. A very high sensitivity FS system was built and applied in the High-Speed Flow Generator (HFG) at NASA LaRC. A LIF system is available at the Advanced Propulsion Laboratory (APL) on campus and a plume exhaust velocity measurement, measuring the Doppler shift from lambda = 728.7 nm of argon gas, is under way.

  14. Startup impurity diagnostics in Wendelstein 7-X stellarator in the first operational phase

    NASA Astrophysics Data System (ADS)

    Thomsen, H.; Langenberg, A.; Zhang, D.; Bertschinger, G.; Biedermann, C.; Biel, W.; Burhenn, R.; Buttenschön, B.; Grosser, K.; König, R.; Kubkowska, M.; Marchuk, O.; Pablant, N.; Ryc, L.; Pedersen, T. S.; the W7-X Team

    2015-10-01

    An essential element for stationary stellarator operation is the understanding of the impurity transport behavior. Neoclassical theory predicts an impurity transport towards the plasma core for the standard ion root regime in stellarators [1,2]. The performance of a quasi-stationary device like Wendelstein 7-X stellarator (W7-X, presently in the commissioning phase in Greifswald, Germany) could be limited in case of strong impurity accumulation. Therefore, a set of plasma diagnostics is foreseen to obtain key experimental quantities for the neoclassical transport modeling as ion temperature profile, density gradients and impurity concentration [1]. The core impurity content is monitored by the High Efficiency eXtreme ultraviolet Overview Spectrometer system (HEXOS) [2], covering the wavelength range 2.5-160 nm (intermediate ionization states of all relevant heavy intrinsic impurity species) with high spectral resolution and a time resolution of 1 ms, adequate for transport analysis. Impurity radiation at shorter wave lengths (4 nm-0.06 nm) will be monitored with the SX pulse height analysis system (PHA) [3]. The ion temperature profile can be deduced from inversion of data from the High Resolution X-ray Imaging Spectrometer (HR-XIS), which measures the concentration and temperature of argon tracer gas in helium-like ionization stages [6,7,8]. A second X-ray Imaging Crystal Spectrometer (XICS), which will additionally provide the poloidal ion rotation velocity, is under preparation [8,9]. The total radiation will be measured by two bolometer cameras [10,11]. The status of the impurity diagnostics for the first operational phase in W7-X is summarized in this paper and an outlook for the next experimental campaign is given.

  15. Hydroxymethyl phosphine compounds for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, Kattesh V.; Karra, Srinivasa Rao; Berning, Douglas E.; Smith, C. Jeffrey; Volkert, Wynn A.; Ketring, Alan R.

    1999-01-01

    A compound and method of making a compound for use as a diagnostic or therapeutic pharmaceutical comprises at least one functionalized hydroxyalkyl phosphine donor group and one or more sulfur or nitrogen donor and a metal combined with the ligand.

  16. Hydroxymethyl phosphine compounds for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, Kattesh V.; Karra, Srinivasa Rao; Berning, Douglas E.; Smith, C. Jeffrey; Volkert, Wynn A.; Ketring, Alan R.

    2000-01-01

    A compound and method of making a compound for use as a diagnostic or therapeutic pharmaceutical comprises at least one functionalized hydroxyalkyl phosphine donor group and one or more sulfur or nitrogen donor and a metal combined with the ligand.

  17. Spectrophotometric Method for Differentiation of Human Skin Melanoma. II. Diagnostic Characteristics

    NASA Astrophysics Data System (ADS)

    Petruk, V. G.; Ivanov, A. P.; Kvaternyuk, S. M.; Barunb, V. V.

    2016-05-01

    Experimental data on the spectral dependences of the optical diffuse reflection coefficient for skin from different people with melanoma or nevus are presented in the form of the probability density of the diffuse reflection coefficient for the corresponding pigmented lesions. We propose a noninvasive technique for differentiating between malignant and benign tumors, based on measuring the diffuse reflection coefficient for a specific patient and comparing the value obtained with a pre-set threshold. If the experimental result is below the threshold, then it is concluded that the person has melanoma; otherwise, no melanoma is present. As an example, we consider the wavelength 870 nm. We determine the risk of malignant transformation of a nevus (its transition to melanoma) for different measured diffuse reflection coefficients. We have studied the errors in the method, its operating characteristics and probability characteristics as the threshold diffuse reflection coefficient is varied. We find that the diagnostic confidence, sensitivity, specificity, and effectiveness (accuracy) parameters are maximum (>0.82) for a threshold of 0.45-0.47. The operating characteristics for the proposed technique exceed the corresponding parameters for other familiar optical approaches to melanoma diagnosis. Its distinguishing feature is operation at only one wavelength, and consequently implementation of the experimental technique is simplified and made less expensive.

  18. Method of operating a neutronic reactor

    DOEpatents

    Woods, Wallace K.

    1976-05-25

    1. A method of operating a reactor having an active portion of a given length between a charging end and a discharging end, a first end region of the reactor extending from the charging end for one-quarter to one-third of said given length, a second end region extending from the discharging end for one-quarter to one-third of said given length, and a middle region extending between said end regions, said method comprising the steps of inserting end to end in the active region through the charging end a first group of bodies filling the middle region and a second group of bodies filling the first end region, irradiating the first and second groups of bodies while in the middle and first end regions, removing the first group from the reactor through the second end region, shifting the second group through the middle region to the second end region, inserting new first and second groups of bodies through the charging face into the middle and first end regions of the reactor, respectively, and irradiating the original second group and the new first and second groups while in the second end, middle, and first end regions, respectively, removing the original second group and the new first group from the reactor through the second end region, shifting the new second group through the middle region to the second end region, and irradiating the new second group again, whereby the first groups of bodies are irradiated only once and the second groups are irradiated twice.

  19. Frequency-Domain Methods for Characterization of Pulsed Power Diagnostics

    SciTech Connect

    White, A D; Anderson, R A; Ferriera, T J; Goerz, D A

    2009-07-27

    This paper discusses methods of frequency-domain characterization of pulsed power sensors using vector network analyzer and spectrum analyzer techniques that offer significant simplification over time-domain methods, while mitigating or minimizing the effect of the difficulties present in time domain characterization. These methods are applicable to characterization of a wide variety of sensors.

  20. A proposed method to estimate receiver operating characteristic curves for chemical and biological sensor standards

    NASA Astrophysics Data System (ADS)

    Davis, H. T.; Merrill, Ezra L.

    2005-05-01

    The Receiver Operating Characteristic curve (ROC) has long been used in medical applications to compare screening and diagnostic methods. As the threshold used by any screening or diagnostic method is changed, the operating characteristics of the method, such as the number of true positive and false negative determinations changes as well. The ROC curve is one way to characterize the changes in order to compare different methods. This definition, however, is difficult to apply to chemical and biological sensors detecting the release of a toxic agent given that there is more than one ROC curve. There is a continuum of ROC curves corresponding to a continuum of release levels. A new definition of ROC curves has been adopted for chemical and biological sensors which will reduce the continuum of curves to a single curve. This paper presents a methodology to estimate ROC curves using this new definition.

  1. Calibration and operational experience with the JET motional Stark effect diagnostic

    SciTech Connect

    Hawkes, N. C.; Brix, M.

    2006-10-15

    Motional Stark effect measurements of the magnetic field pitch angle on JET present several difficulties most serious of which is that the injection systems consist of more than one source, each with a different motional stark effect (MSE) angle. Attempts to describe the net polarization angle, within the EFIT equilibrium code, using the weighted sum of Stokes vectors, have proved inaccurate. Instead we rely on spectrally isolating the emission of a single source. Beam power modulation is helpful in differentiating background polarized light, but this technique fails in the presence of strong edge localized mode (ELMs). Calibration is difficult because of the presence of a mirror in the optical system. The mirror introduces a large optical phase shift which means that the polarimeter has to resolve circular as well as linear polarized components. Basic calibration is carried out off the tokamak using a motorized rotary encoder stage and a six-parameter physical model of the optical and electronic systems. This is readjusted using plasma emission, for mirror operation at 300 deg. C. Some of the operating experience obtained with the JET MSE diagnostic will be relevant to ITER, although the lack of independent power or voltage control of the ITER injectors is seen as the chief challenge facing the ITER MSE design.

  2. Wavelet and multiscale methods for operator equations

    NASA Astrophysics Data System (ADS)

    Dahmen, Wolfgang

    More than anything else, the increase of computing power seems to stimulate the greed for tackling ever larger problems involving large-scale numerical simulation. As a consequence, the need for understanding something like the intrinsic complexity of a problem occupies a more and more pivotal position. Moreover, computability often only becomes feasible if an algorithm can be found that is asymptotically optimal. This means that storage and the number of floating point operations needed to resolve the problem with desired accuracy remain proportional to the problem size when the resolution of the discretization is refined. A significant reduction of complexity is indeed often possible, when the underlying problem admits a continuous model in terms of differential or integral equations. The physical phenomena behind such a model usually exhibit characteristic features over a wide range of scales. Accordingly, the most successful numerical schemes exploit in one way or another the interaction of different scales of discretization. A very prominent representative is the multigrid methodology; see, for instance, Hackbusch (1985) and Bramble (1993). In a way it has caused a breakthrough in numerical analysis since, in an important range of cases, it does indeed provide asymptotically optimal schemes. For closely related multilevel techniques and a unified treatment of several variants, such as multiplicative or additive subspace correction methods, see Bramble, Pasciak and Xu (1990), Oswald (1994), Xu (1992), and Yserentant (1993). Although there remain many unresolved problems, multigrid or multilevel schemes in the classical framework of finite difference and finite element discretizations exhibit by now a comparatively clear profile. They are particularly powerful for elliptic and parabolic problems.

  3. Tokamak physics studies using x-ray diagnostic methods

    SciTech Connect

    Hill, K.W.; Bitter, M.; von Goeler, S.; Beiersdorfer, P.; Fredrickson, E.; Hsuan, H.; McGuire, K.; Sauthoff, N.R.; Sesnic, S.; Stevens, J.E.

    1987-03-01

    X-ray diagnostic measurements have been used in a number of experiments to improve our understanding of important tokamak physics issues. The impurity content in TFTR plasmas, its sources and control have been clarified through soft x-ray pulse-height analysis (PHA) measurements. The dependence of intrinsic impurity concentrations and Z/sub eff/ on electron density, plasma current, limiter material and conditioning, and neutral-beam power have shown that the limiter is an important source of metal impurities. Neoclassical-like impurity peaking following hydrogen pellet injection into Alcator C and a strong effect of impurities on sawtooth behavior were demonstrated by x-ray imaging (XIS) measurements. Rapid inward motion of impurities and continuation of m = 1 activity following an internal disruption were demonstrated with XIS measurements on PLT using injected aluminum to enhance the signals. Ion temperatures up to 12 keV and a toroidal plasma rotation velocity up to 6 x 10/sup 5/ m/s have been measured by an x-ray crystal spectrometer (XCS) with up to 13 MW of 85-keV neutral-beam injection in TFTR. Precise wavelengths and relative intensities of x-ray lines in several helium-like ions and neon-like ions of silver have been measured in TFTR and PLT by the XCS. The data help to identify the important excitation processes predicted in atomic physics. Wavelengths of n = 3 to 2 silver lines of interest for x-ray lasers were measured, and precise instrument calibration techniques were developed. Electron thermal conductivity and sawtooth dynamics have been studied through XIS measurements on TFTR of heat-pulse propagation and compound sawteeth. A non-Maxwellian electron distribution function has been measured, and evidence of the Parail-Pogutse instability identified by hard x-ray PHA measurements on PLT during lower-hybrid current-drive experiments.

  4. A Simplified Diagnostic Method for Elastomer Bond Durability

    NASA Technical Reports Server (NTRS)

    White, Paul

    2009-01-01

    A simplified method has been developed for determining bond durability under exposure to water or high humidity conditions. It uses a small number of test specimens with relatively short times of water exposure at elevated temperature. The method is also gravimetric; the only equipment being required is an oven, specimen jars, and a conventional laboratory balance.

  5. Restrictive Stochastic Item Selection Methods in Cognitive Diagnostic Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Wang, Chun; Chang, Hua-Hua; Huebner, Alan

    2011-01-01

    This paper proposes two new item selection methods for cognitive diagnostic computerized adaptive testing: the restrictive progressive method and the restrictive threshold method. They are built upon the posterior weighted Kullback-Leibler (KL) information index but include additional stochastic components either in the item selection index or in…

  6. Optical methods for diagnostic of cell-tissue grafts

    NASA Astrophysics Data System (ADS)

    Timchenko, P. E.; Timchenko, E. V.; Volova, L. T.; Boltovskaya, V. V.; Zherdeva, L. A.; Belousov, N. V.; Pershutkina, S. V.

    2015-08-01

    In this work the results of cell-tissue grafts research with a complex of optical methods - confocal fluorescent microscopy and Raman spectroscopy are presented. It was established that coefficient M scatter is related to irregularity of demineralization process. It was microscopically shown that the quantity of integrated cells into these types of transplants amounts to 20% of its surface.

  7. Calreticulin Mutations in Myeloproliferative Neoplasms: Comparison of Three Diagnostic Methods

    PubMed Central

    Park, Ji-Hye; Sevin, Margaux; Ramla, Selim; Truffot, Aurélie; Verrier, Tiffany; Bouchot, Dominique; Courtois, Martine; Bas, Mathilde; Benali, Sonia; Bailly, François; Favre, Bernardine; Guy, Julien; Martin, Laurent; Maynadié, Marc; Carillo, Serge; Girodon, François

    2015-01-01

    Calreticulin (CALR) mutations have recently been reported in 70–84% of JAK2V617F-negative myeloproliferative neoplasms (MPN), and this detection has become necessary to improve the diagnosis of MPN. In a large single-centre cohort of 298 patients suffering from Essential Thrombocythemia (ET), the JAK2V617F, CALR and MPL mutations were noted in 179 (60%), 56 (18.5%) and 13 (4.5%) respectively. For the detection of the CALR mutations, three methods were compared in parallel: high-resolution melting-curve analysis (HRM), product-sizing analysis and Sanger sequencing. The sensitivity for the HRM, product-sizing analysis and Sanger sequencing was 96.4%, 98.2% and 89.3% respectively, whereas the specificity was 96.3%, 100% and 100%. In our cohort, the product-sizing analysis was the most sensitive method and was the easiest to interpret, while the HRM was sometimes difficult to interpret. In contrast, when large series of samples were tested, HRM provided results more quickly than did the other methods, which required more time. Finally, the sequencing method, which is the reference method, had the lowest sensitivity but can be used to describe the type of mutation precisely. Altogether, our results suggest that in routine laboratory practice, product-sizing analysis is globally similar to HRM for the detection of CALR mutations, and that both may be used as first-line screening tests. If the results are positive, Sanger sequencing can be used to confirm the mutation and to determine its type. Product-sizing analysis provides sensitive and specific results, moreover, with the quantitative measurement of CALR, which might be useful to monitor specific treatments. PMID:26501981

  8. Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty.

    PubMed

    Zorzetto, M; Bernardi, G; Morocutti, G; Fontanelli, A

    1997-04-01

    A detailed monitoring, on the basis of single procedures, was undertaken to assess the patient exposure and the occupational doses received by the operators (cardiologist, technician, and nurse) during diagnostic coronary angiography (CAG) and percutaneous transluminal coronary angioplasty (PTCA). The occupational dose to the staff was measured at the collar level using thermoluminescent dosimeters (TLD) to examine the neck and head exposure. Patient exposure was assessed by the dose-area product (DAP in Gy/cm2) and by the skin dose (mGy) at the level of thyroid. The mean neck dose per procedure for cardiologist was about 0.05 mGy, a reasonable level to comply with the International Commission on Radiological Protection (ICRP) eye lens recommended limit. No significant differences were detected between CAG (39 procedures) and PTCA (19 procedures). Relatively high radiation doses are given to the lung of the patient with a significant ICRP lifetime risk of about 10(-3). The patients' mean DAP was 55.9 Gy/cm2 for CAG (79 procedures) and 91.8 Gy/cm2 for PTCA (31 procedures) (P < 0.01). About 70% in CAG and 48% in PTCA of the total dose resulted from the cine examination; in PTCA the total mean DAP was about 60% higher than in CAG procedures. PMID:9096931

  9. Multiple light scattering methods for multiphase flow diagnostics

    NASA Astrophysics Data System (ADS)

    Estevadeordal, Jordi

    2015-11-01

    Multiphase flows of gases and liquids containing droplets, bubbles, or particulates present light scattering imaging challenges due to the interference from each phase, such as secondary reflections, extinctions, absorptions, and refractions. These factors often prevent the unambiguous detection of each phase and also produce undesired beam steering. The effects can be especially complex in presence of dense phases, multispecies flows, and high pressure environments. This investigation reports new methods for overcoming these effects for quantitative measurements of velocity, density, and temperature fields. The methods are based on light scattering techniques combining Mie and filtered Rayleigh scattering and light extinction analyses and measurements. The optical layout is designed to perform multiple property measurements with improved signal from each phase via laser spectral and polarization characterization, etalon decontamination, and use of multiple wavelengths and imaging detectors.

  10. Fraley's syndrome: case report and update on current diagnostic methods

    SciTech Connect

    Zuckier, L.S.; Patel, Y.D.; Fine, E.J.; Koenigsberg, M.

    1988-01-01

    A 38-year-old woman presented with fever, right flank pain, and a clinical diagnosis of pyelonephritis. Work-up revealed the presence of a crossing arterial branch causing obstruction of the superior infundibulum of the right kidney, which is an uncommon cause of nephralgia and urinary infection initially described by Fraley in 1966. Intravenous urography, retrograde pyelography, and angiography remain the mainstay of diagnosis, much as in the initial descriptions of this entity. (/sup 131/I)Hippuran imaging, with analysis of the upper and lower pole regions of interest, provides a simple yet powerful method of evaluating functional and excretory changes in the superior infundibulum, and has proved more efficacious than previously reported whole-kidney renograms. Renal scintigraphy represents a relatively noninvasive method of serial functional examination in this disorder. Ultrasound imaging, by monitoring upper-pole dilatation, may provide complementary morphologic information important for long-term follow-up.

  11. Apparatus and method for monitoring breath acetone and diabetic diagnostics

    DOEpatents

    Duan, Yixiang; Cao, Wenqing

    2008-08-26

    An apparatus and method for monitoring diabetes through breath acetone detection and quantitation employs a microplasma source in combination with a spectrometer. The microplasma source provides sufficient energy to produce excited acetone fragments from the breath gas that emit light. The emitted light is sent to the spectrometer, which generates an emission spectrum that is used to detect and quantify acetone in the breath gas.

  12. Stably operating pulse combustor and method

    DOEpatents

    Zinn, Ben T.; Reiner, David

    1990-01-01

    A pulse combustor apparatus adapted to burn either a liquid fuel or a pulverized solid fuel within a preselected volume of the combustion chamber. The combustion process is substantially restricted to an optimum combustion zone in order to attain effective pulse combustion operation.

  13. Stably operating pulse combustor and method

    DOEpatents

    Zinn, B.T.; Reiner, D.

    1990-05-29

    A pulse combustor apparatus is described which is adapted to burn either a liquid fuel or a pulverized solid fuel within a preselected volume of the combustion chamber. The combustion process is substantially restricted to an optimum combustion zone in order to attain effective pulse combustion operation. 4 figs.

  14. Control Methods of Operational Properties of Lubricants

    NASA Astrophysics Data System (ADS)

    Lysyannikova, N.; Kovalski, B.; Bezborodov, Yu; Lysyannikov, A.; Kravtsova, Ye; Shram, V.; Kovaleva, M.

    2016-06-01

    Some results of thermal-oxidation and temperature stability testing of motor oils are presented. The catalytic influence of metals on oxidizing processes in lubricants with use of steel 45 was determined. The parameters for identification of oils by groups of operational properties and quantity indicators of the influence of metals on oxidizing processes of lubricants are offered.

  15. Operator Influence on Blinded Diagnostic Accuracy of Point-of-Care Antigen Testing for Group A Streptococcal Pharyngitis.

    PubMed

    Penney, Carla; Porter, Robert; O'Brien, Mary; Daley, Peter

    2016-01-01

    Background. Acute pharyngitis caused by Group A Streptococcus (GAS) is a common presentation to pediatric emergency departments (ED). Diagnosis with conventional throat culture requires 18-24 hours, which prevents point-of-care treatment decisions. Rapid antigen detection tests (RADT) are faster, but previous reports demonstrate significant operator influence on performance. Objective. To measure operator influence on the diagnostic accuracy of a RADT when performed by pediatric ED nurses and clinical microbiology laboratory technologists, using conventional culture as the reference standard. Methods. Children presenting to a pediatric ED with suspected acute pharyngitis were recruited. Three pharyngeal swabs were collected at once. One swab was used to perform the RADT in the ED, and two were sent to the clinical microbiology laboratory for RADT and conventional culture testing. Results. The RADT when performed by technologists compared to nurses had a 5.1% increased sensitivity (81.4% versus 76.3%) (p = 0.791) (95% CI for difference between technologists and nurses = -11% to +21%) but similar specificity (97.7% versus 96.6%). Conclusion. The performance of the RADT was similar between technologists and ED nurses, although adequate power was not achieved. RADT may be employed in the ED without clinically significant loss of sensitivity. PMID:27579047

  16. Operator Influence on Blinded Diagnostic Accuracy of Point-of-Care Antigen Testing for Group A Streptococcal Pharyngitis

    PubMed Central

    O'Brien, Mary

    2016-01-01

    Background. Acute pharyngitis caused by Group A Streptococcus (GAS) is a common presentation to pediatric emergency departments (ED). Diagnosis with conventional throat culture requires 18–24 hours, which prevents point-of-care treatment decisions. Rapid antigen detection tests (RADT) are faster, but previous reports demonstrate significant operator influence on performance. Objective. To measure operator influence on the diagnostic accuracy of a RADT when performed by pediatric ED nurses and clinical microbiology laboratory technologists, using conventional culture as the reference standard. Methods. Children presenting to a pediatric ED with suspected acute pharyngitis were recruited. Three pharyngeal swabs were collected at once. One swab was used to perform the RADT in the ED, and two were sent to the clinical microbiology laboratory for RADT and conventional culture testing. Results. The RADT when performed by technologists compared to nurses had a 5.1% increased sensitivity (81.4% versus 76.3%) (p = 0.791) (95% CI for difference between technologists and nurses = −11% to +21%) but similar specificity (97.7% versus 96.6%). Conclusion. The performance of the RADT was similar between technologists and ED nurses, although adequate power was not achieved. RADT may be employed in the ED without clinically significant loss of sensitivity. PMID:27579047

  17. Diagnostic imaging methods applied in long-term surveillance after EVAR. Will computed tomography angiography be replaced by other methods?

    PubMed Central

    Stefaniak, Karolina; Gabriel, Marcin; Oszkinis, Grzegorz

    2016-01-01

    Endovascular implantation of a stent graft in the abdominal aorta (endovascular aneurysm repair – EVAR) is a widely accepted alternative to open surgery in treatment of abdominal aortic aneurysms. Although EVAR is connected with a significant reduction in the risk of peri- and post-operative complications, it does not eliminate them totally. Long-term surveillance of post-EVAR patients is aimed at early detection of and fast reaction to a group of complications called endovascular leaks. Currently, the gold standard in leak diagnostics is computed tomography angiography (CTA). The other methods are ultrasonography, magnetic resonance (MR) angiography, intra-aneurysm sac pressure measurement, X-ray, and digital subtraction angiography (DSA). Despite many analyses based on long-term research, emphasising the high value and competitiveness of less invasive tests such as US or X-ray compared to CTA, it is still difficult for them to win the trust and acceptance of clinicians. The persisting view is that computed tomography is the test that finally resolves any inaccuracies. Consequently, a patient with a number of concurrent diseases is subject to absurdly high radiation exposure and effects of a radiocontrast agent within a short time. It is therefore logical to acknowledge that the EVAR-related risk is catching up with the open surgery risk, while the endovascular procedure is much more costly. Nevertheless, the status of CTA as the gold standard ultimately seems to be unthreatened. This paper presents a description of the diagnostic imaging tests that make it possible to detect any vascular leaks and to develop strategies for therapeutic processes. PMID:26966443

  18. Using the Attribute Hierarchy Method to Make Diagnostic Inferences about Examinees' Cognitive Skills in Critical Reading

    ERIC Educational Resources Information Center

    Wang, Changjiang; Gierl, Mark J.

    2011-01-01

    The purpose of this study is to apply the attribute hierarchy method (AHM) to a subset of SAT critical reading items and illustrate how the method can be used to promote cognitive diagnostic inferences. The AHM is a psychometric procedure for classifying examinees' test item responses into a set of attribute mastery patterns associated with…

  19. Making Diagnostic Inferences about Cognitive Attributes Using the Rule-Space Model and Attribute Hierarchy Method

    ERIC Educational Resources Information Center

    Gierl, Mark J.

    2007-01-01

    The purpose of this paper is to describe the logic and identify key assumptions associated with making cognitive inferences using two attribute-based psychometric methods. The first method is Kikumi Tatsuoka's rule-space model. This model provides a strong point of reference for studying the nature of diagnostic inferences because it is important…

  20. Method of hepatitis diagnostics of changes in human skin diffuse reflectivity

    NASA Astrophysics Data System (ADS)

    Kirsh, M. L.; Sokol, A. M.; Lomanets, V. S.; Gayka, O. R.

    1999-11-01

    The results on the study of influence of bilirubinum concentration in a human blood on the spectrum of a diffuse reflectivity of his skin are represented. On this basis, the method for hepatitis diagnostics has been developed, and the laboratory device implementing this method has been designed.

  1. Thomson scattering as a method for laser plasma diagnostics

    SciTech Connect

    Alayi, Y.

    1983-12-01

    The Thomson scattering has been used to determine the density and temperature of an inhomogeneous nonstationary plasma. A common method to calibrate the Thomson scattering device consists in replacing the plasma by a gas and measuring the Rayleigh scattering cross section. The angular distribution of the scattered light in Argon is measured, the incident light is a ruby laser with ..delta..t = 30ns and lambda = 6943nm and vertically polarized. We have found that angular distribution is strongly favored in the forward direction (30/sup 0/, 45/sup 0/, 60/sup 0/) and defavored for backward direction (90/sup 0/, 120/sup 0/, 135/sup 0/, 150/sup 0/) in agreement with the results of George, et al, but in disagreement with the Rayleigh theory which assumes a uniform distribution. Our results may be related to the form of the scattered light spectrum which undergoes a dramatic change through the kinetic-hydrodynamic transition. The general form of the spectrum is determined by the parameter y = 1/Kl (where K = 4..pi.. sin (theta/2)/lambda, theta is the scattering angle and l is the free path path), which increases in the direction of the hydrodynamic regime (small angles). By analogy, the Thomson scattering presents the same aspects with ..cap alpha.. = 1/Klambda /SUB D/ (where lambda /SUB D/ is the Debye length). The deviation from the uniform distribution provides the possibility to determine the plasma turbulence spectrum from the scattered light.

  2. Agile Development Methods for Space Operations

    NASA Technical Reports Server (NTRS)

    Trimble, Jay; Webster, Chris

    2012-01-01

    Main stream industry software development practice has gone from a traditional waterfall process to agile iterative development that allows for fast response to customer inputs and produces higher quality software at lower cost. How can we, the space ops community, adopt state of the art software development practice, achieve greater productivity at lower cost, and maintain safe and effective space flight operations? At NASA Ames, we are developing Mission Control Technologies Software, in collaboration with Johnson Space Center (JSC) and, more recently, the Jet Propulsion Laboratory (JPL).

  3. Characterization and diagnostic methods for geomagnetic auroral infrasound waves

    NASA Astrophysics Data System (ADS)

    Oldham, Justin J.

    Infrasonic perturbations resulting from auroral activity have been observed since the 1950's. In the last decade advances in infrasonic microphone sensitivity, high latitude sensor coverage, time series analysis methods and computational efficiency have elucidated new types of auroral infrasound. Persistent periods of infrasonic activity associated with geomagnetic sub-storms have been termed geomagnetic auroral infrasound waves [GAIW]. We consider 63 GAIW events recorded by the Fairbanks, AK infrasonic array I53US ranging from 2003 to 2014 and encompassing a complete solar cycle. We make observations of the acoustic features of these events alongside magnetometer, riometer, and all-sky camera data in an effort to quantify the ionospheric conditions suitable for infrasound generation. We find that, on average, the generation mechanism for GAIW is confined to a region centered about ~60 0 longitude east of the anti-Sun-Earth line and at ~770 North latitude. We note furthermore that in all cases considered wherein imaging riometer data are available, that dynamic regions of heightened ionospheric conductivity periodically cross the overhead zenith. Consistent features in concurrent magnetometer conditions are also noted, with irregular oscillations in the horizontal component of the field ubiquitous in all cases. In an effort to produce ionosphere based infrasound free from the clutter and unknowns typical of geophysical observations, an experiment was undertaken at the High Frequency Active Auroral Research Program [HAARP] facility in 2012. Infrasonic signals appearing to originate from a source region overhead were observed briefly on 9 August 2012. The signals were observed during a period when an electrojet current was presumed to have passed overhead and while the facilities radio transmitter was periodically heating the lower ionosphere. Our results suggest dynamic auroral electrojet currents as primary sources of much of the observed infrasound, with

  4. Zenker’s diverticulum: aetiopathogenesis, symptoms and diagnosis. Comparison of operative methods

    PubMed Central

    Nehring, Piotr

    2013-01-01

    Zenker’s diverticulum is an alimentary tract pouch localized in the area of the upper esophageal sphincter. Treatment procedure complications and coexisting diseases constitute a serious diagnostic and therapeutic problem. Characteristic symptoms and signs facilitate differential diagnosis, simultaneously being real patient maladies. There are many treatment procedures leading to pouch septum reduction and decrease of upper esophageal sphincter pressure. After years of experience in operating and endoscopic treatments we found it necessary to compare these different methods. PMID:24868270

  5. New method of acne disease fluorescent diagnostics in natural and fluorescent light and treatment control

    NASA Astrophysics Data System (ADS)

    Karimova, L. N.; Berezin, A. N.; Shevchik, S. A.; Kharnas, S. S.; Kusmin, S. G.; Loschenov, V. B.

    2005-08-01

    In the given research the new method of fluorescent diagnostics (FD) and photodynamic therapy (PDT) control of acne disease is submitted. Method is based on simultaneous diagnostics in natural and fluorescent light. PDT was based on using 5-ALA (5- aminolevulinic acid) preparation and 600-730 nanometers radiation. If the examined site of a skin possessed a high endogenous porphyrin fluorescence level, PDT was carried out without 5-ALA. For FD and treatment control a dot spectroscopy and the fluorescent imaging of the affected skin were used.

  6. Diagnostic test accuracy: methods for systematic review and meta-analysis.

    PubMed

    Campbell, Jared M; Klugar, Miloslav; Ding, Sandrine; Carmody, Dennis P; Hakonsen, Sasja J; Jadotte, Yuri T; White, Sarahlouise; Munn, Zachary

    2015-09-01

    Systematic reviews are carried out to provide an answer to a clinical question based on all available evidence (published and unpublished), to critically appraise the quality of studies, and account for and explain variations between the results of studies. The Joanna Briggs Institute specializes in providing methodological guidance for the conduct of systematic reviews and has developed methods and guidance for reviewers conducting systematic reviews of studies of diagnostic test accuracy. Diagnostic tests are used to identify the presence or absence of a condition for the purpose of developing an appropriate treatment plan. Owing to demands for improvements in speed, cost, ease of performance, patient safety, and accuracy, new diagnostic tests are continuously developed, and there are often several tests available for the diagnosis of a particular condition. In order to provide the evidence necessary for clinicians and other healthcare professionals to make informed decisions regarding the optimum test to use, primary studies need to be carried out on the accuracy of diagnostic tests and the results of these studies synthesized through systematic review. The Joanna Briggs Institute and its international collaboration have updated, revised, and developed new guidance for systematic reviews, including systematic reviews of diagnostic test accuracy. This methodological article summarizes that guidance and provides detailed advice on the effective conduct of systematic reviews of diagnostic test accuracy. PMID:26355602

  7. The Accuracy of Diagnostic Methods for Diabetic Retinopathy: A Systematic Review and Meta-Analysis

    PubMed Central

    Martínez-Vizcaíno, Vicente; Cavero-Redondo, Iván; Álvarez-Bueno, Celia; Rodríguez-Artalejo, Fernando

    2016-01-01

    Objective The objective of this study was to evaluate the accuracy of the recommended glycemic measures for diagnosing diabetic retinopathy. Methods We systematically searched MEDLINE, EMBASE, the Cochrane Library, and the Web of Science databases from inception to July 2015 for observational studies comparing the diagnostic accuracy of glycated hemoglobin (HbA1c), fasting plasma glucose (FPG), and 2-hour plasma glucose (2h-PG). Random effects models for the diagnostic odds ratio (dOR) value computed by Moses’ constant for a linear model and 95% CIs were used to calculate the accuracy of the test. Hierarchical summary receiver operating characteristic curves (HSROC) were used to summarize the overall test performance. Results Eleven published studies were included in the meta-analysis. The pooled dOR values for the diagnosis of retinopathy were 16.32 (95% CI 13.86–19.22) for HbA1c and 4.87 (95% CI 4.39–5.40) for FPG. The area under the HSROC was 0.837 (95% CI 0.781–0.892) for HbA1c and 0.735 (95% CI 0.657–0.813) for FPG. The 95% confidence region for the point that summarizes the overall test performance of the included studies occurs where the cut-offs ranged from 6.1% (43.2 mmol/mol) to 7.8% (61.7 mmol/mol) for HbA1c and from 7.8 to 9.3 mmol/L for FPG. In the four studies that provided information regarding 2h-PG, the pooled accuracy estimates for HbA1c were similar to those of 2h-PG; the overall performance for HbA1c was superior to that for FPG. Conclusions The three recommended tests for the diagnosis of type 2 diabetes in nonpregnant adults showed sufficient accuracy for their use in clinical settings, although the overall accuracy for the diagnosis of retinopathy was similar for HbA1c and 2h-PG, which were both more accurate than for FPG. Due to the variability and inconveniences of the glucose level-based methods, HbA1c appears to be the most appropriate method for the diagnosis diabetic retinopathy. PMID:27123641

  8. Hydrogasification reactor and method of operating same

    DOEpatents

    Hobbs, Raymond; Karner, Donald; Sun, Xiaolei; Boyle, John; Noguchi, Fuyuki

    2013-09-10

    The present invention provides a system and method for evaluating effects of process parameters on hydrogasification processes. The system includes a hydrogasification reactor, a pressurized feed system, a hopper system, a hydrogen gas source, and a carrier gas source. Pressurized carbonaceous material, such as coal, is fed to the reactor using the carrier gas and reacted with hydrogen to produce natural gas.

  9. Performance factors as a basis of practical fault detection and diagnostic methods for air-handling units

    SciTech Connect

    Kaerki, S.H.; Karjalainen, S.J.

    1999-07-01

    The technical term performance is defined as how well a system fulfills its intended purpose in different operational circumstances. This paper describes the process of establishing the performance factors of air-handling units (AHUs), defining the performance requirements, and connecting them to fault detection and diagnosis methods. The most important performance requirements of AHUs are related to heating and cooling energy, the supply airflow rate and purity, energy efficiency, and control quality. Many solutions made during different life-cycle phases affect the final system performance. These solutions are discussed in this paper. Diagnostic tools and methods can be developed for monitoring the defined performance criteria. Practical FDD methods have been developed for the system considered here. The methods are simple and easy to apply in practice. Methods for monitoring the heat recovery unit and the AHU energy use are presented. Examples of utilizing characteristic curves and fault-symptom trees are also described.

  10. Are the classic diagnostic methods in mycology still state of the art?

    PubMed

    Wiegand, Cornelia; Bauer, Andrea; Brasch, Jochen; Nenoff, Pietro; Schaller, Martin; Mayser, Peter; Hipler, Uta-Christina; Elsner, Peter

    2016-05-01

    The diagnostic workup of cutaneous fungal infections is traditionally based on microscopic KOH preparations as well as culturing of the causative organism from sample material. Another possible option is the detection of fungal elements by dermatohistology. If performed correctly, these methods are generally suitable for the diagnosis of mycoses. However, the advent of personalized medicine and the tasks arising therefrom require new procedures marked by simplicity, specificity, and swiftness. The additional use of DNA-based molecular techniques further enhances sensitivity and diagnostic specificity, and reduces the diagnostic interval to 24-48 hours, compared to weeks required for conventional mycological methods. Given the steady evolution in the field of personalized medicine, simple analytical PCR-based systems are conceivable, which allow for instant diagnosis of dermatophytes in the dermatology office (point-of-care tests). PMID:27119470

  11. Damage diagnosis for SHM of existing civil structure with statistical diagnostic method

    NASA Astrophysics Data System (ADS)

    Iwasaki, Atsushi; Todoroki, Akira; Sugiya, Tsuneya; Sakai, Shinsuke

    2004-07-01

    The present research proposes a new automatic damage diagnostic method that does not require data of damaged state. Structural health monitoring is a noticeable technology for civil structures. Multiple damage diagnostic method for has been proposed, and most of them employ parametric method based on modeling or non-parametric method such as artificial neural networks. These methods demand much costs, and first of all, it is impossible to obtain data for training of damaged existing structures. That causes importance of development of the method, which diagnoses damage just from data of the intact state structure for existing structures. Therefore we purpose new statistical diagnostic method for structural damage detection. In the present method, system identification using a response surface is performed and damage is diagnosed by testing the change of this identified system by statistical test. The new method requires data of non-damaged state and does not require the complicated modeling and data of damaged state structure. As an example, the present study deals damage diagnosis of a jet-fan which installed to a tunnel on an expressway as a ventilator fan. Damages are detected from load of turnbuckles. As a result, the damage is successfully diagnosed with the method.

  12. Method of operating horizontal coke oven batteries

    SciTech Connect

    Strobel, M.; Thiersch, F.B.

    1981-09-22

    A horizontal coke oven battery construction in which a pusher is mounted to extend into the batteries from one side and push coke out of the batteries on the opposite side, comprises a plurality of coke oven batteries disposed in a row. A first waste gas flue extends along the pusher side of the batteries and a second waste gas flue extends along the coke side. A stack flue at one end of the batteries is connected to the first and second waste gas flues. The construction includes means for directing the heating gases into each oven battery during operation so that, in respect to the pusher and coke size, approximately one-half of the batteries is heated by upward burning and the other half is heated by downward burning. For example, all odd numbered batteries may be heated in the same direction and all even numbered batteries heated in the same direction. The invention also comprises a two-section regenerative heating system having reversing winches wherein the heating on one-half or approximately one-half of the oven chambers is equipped for upward burning and the heating of the other half is equipped with downward burning. Between the two halves, a center head maybe be provided, or only one reversing winch may be provided at the end of the battery.

  13. Hydroxyalkyl phosphine gold complexes for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, K.V.; Berning, D.E.; Volkert, W.A.; Ketring, A.R.

    1998-12-01

    A complex and method for making a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids. 20 figs.

  14. Hydroxyalkyl phosphine gold complexes for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, Kattesh V.; Berning, Douglas E.; Volkert, Wynn A.; Ketring, Alan R.

    1998-01-01

    A complex and method for making same for use as a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids.

  15. Hydroxymethyl phosphine compounds for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, K.V.; Karra, S.R.; Berning, D.E.; Smith, C.J.; Volkert, W.A.; Ketring, A.R.

    1999-01-05

    A compound and method of making a compound for use as a diagnostic or therapeutic pharmaceutical comprises at least one functionalized hydroxyalkyl phosphine donor group and one or more sulfur or nitrogen donor and a metal combined with the ligand. 21 figs.

  16. Validation of a Theoretical Model of Diagnostic Classroom Assessment: A Mixed Methods Study

    ERIC Educational Resources Information Center

    Koh, Nancy

    2012-01-01

    The purpose of the study was to validate a theoretical model of diagnostic, formative classroom assessment called, "Proximal Assessment for Learner Diagnosis" (PALD). To achieve its purpose, the study employed a two-stage, mixed-methods design. The study utilized multiple data sources from 11 elementary level mathematics teachers who…

  17. Patents on diagnostic methods in Europe under the European Patent Convention (EPC).

    PubMed

    Barba, Michelangelo

    2010-01-01

    This article reviews the provisions of the European Patent Convention with regard to diagnostic methods practiced on the human or animal body. Moreover, it is also discussed the relevant jurisprudence (Case Law) interpreting the legal provisions. Some examples based on real cases are also presented and discussed. PMID:21095714

  18. Depression and Spinal Cord Injury: A Review of Diagnostic Methods for Depression, 1985 to 2000.

    ERIC Educational Resources Information Center

    Skinner, Amy L.; Armstrong, Kevin J.; Rich, John

    2003-01-01

    Studies of depression in individuals with spinal cord injuries (SCI) over a 15-year period were examined to determine if researchers used consistent diagnostic measures. The Beck Depression Inventory was the most frequently used instrument, but there was inconsistency among methods employed and disagreement regarding the inclusion of somatic…

  19. Estimation of diagnostic test accuracy without full verification: a review of latent class methods

    PubMed Central

    Collins, John; Huynh, Minh

    2014-01-01

    The performance of a diagnostic test is best evaluated against a reference test that is without error. For many diseases, this is not possible, and an imperfect reference test must be used. However, diagnostic accuracy estimates may be biased if inaccurately verified status is used as the truth. Statistical models have been developed to handle this situation by treating disease as a latent variable. In this paper, we conduct a systematized review of statistical methods using latent class models for estimating test accuracy and disease prevalence in the absence of complete verification. PMID:24910172

  20. Optical Diagnostic Characterization of High-Power Hall Thruster Wear and Operation

    NASA Technical Reports Server (NTRS)

    Williams, George J., Jr.; Soulas, George C.; Kamhawi, Hani

    2012-01-01

    Optical emission spectroscopy is employed to correlate BN insulator erosion with high-power Hall thruster operation. Specifically, actinometry leveraging excited xenon states is used to normalize the emission spectra of ground state boron as a function of thruster operating condition. Trends in the strength of the boron signal are correlated with thruster power, discharge voltage, and discharge current. In addition, the technique is demonstrated on metallic coupons embedded in the walls of the HiVHAc EM thruster. The OES technique captured the overall trend in the erosion of the coupons which boosts credibility in the method since there are no data to which to calibrate the erosion rates of high-power Hall thrusters. The boron signals are shown to trend linearly with discharge voltage for a fixed discharge current as expected. However, the boron signals of the higher-power NASA 300M and NASA 457Mv2 trend with discharge current and show an unexpectedly weak to inverse dependence on discharge voltage. Electron temperatures measured optically in the near-field plume of the thruster agree well with Langmuir probe data. However, the optical technique used to determine Te showed unacceptable sensitivity to the emission intensities. Near-field, single-frequency imaging of the xenon neutrals is also presented as a function of operating condition for the NASA 457 Mv2.

  1. CT-guided percutaneous aspiration of Tarlov cyst as a useful diagnostic procedure prior to operative intervention.

    PubMed

    Lee, J-Y; Impekoven, P; Stenzel, W; Löhr, M; Ernestus, R-I; Klug, N

    2004-07-01

    Tarlov or perineural cysts are lesions of the nerve root most often found in the sacral region. Several authors recommend surgical treatment of symptomatic Tarlov cysts. However, successful surgical treatment is dependent on appropriate patient selection. In this article, we report three cases of a sacral perineural cyst, causing sciatic pain, and emphasize the usefulness of CT-guided percutaneous aspiration as an important diagnostic and prognostic procedure prior to definitive operative treatment. PMID:15197609

  2. System and method of operating toroidal magnetic confinement devices

    DOEpatents

    Chance, M.S.; Jardin, S.C.; Stix, T.H.; Grimm, R.C.; Manickam, J.; Okabayashi, M.

    1984-08-30

    This invention pertains to methods and arrangements for attaining high beta values in plasma confinement devices. More specifically, this invention pertains to methods for accessing the second stability region of operation in toroidal magnetic confinement devices.

  3. 12 CFR 1101.3 - Organization and methods of operation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Organization and methods of operation. 1101.3..., PROCEDURES, PUBLIC INFORMATION § 1101.3 Organization and methods of operation. (a) Statutory requirements... securing the services, as needed, of staff experts from the five agencies; supervising research and...

  4. Method for assessing motor insulation on operating motors

    DOEpatents

    Kueck, J.D.; Otaduy, P.J.

    1997-03-18

    A method for monitoring the condition of electrical-motor-driven devices is disclosed. The method is achieved by monitoring electrical variables associated with the functioning of an operating motor, applying these electrical variables to a three phase equivalent circuit and determining non-symmetrical faults in the operating motor based upon symmetrical components analysis techniques. 15 figs.

  5. Method for assessing motor insulation on operating motors

    DOEpatents

    Kueck, John D.; Otaduy, Pedro J.

    1997-01-01

    A method for monitoring the condition of electrical-motor-driven devices. The method is achieved by monitoring electrical variables associated with the functioning of an operating motor, applying these electrical variables to a three phase equivalent circuit and determining non-symmetrical faults in the operating motor based upon symmetrical components analysis techniques.

  6. Comparison of laser spectroscopic PNC method with laser integral fluorescence in optical caries diagnostics

    NASA Astrophysics Data System (ADS)

    Masychev, Victor I.

    2001-05-01

    In this research we represent the results of approbation of two methods of optical caries diagnostics: PNC-spectral diagnostics and caries detection by laser integral fluorescence. The research was conducted in a dental clinic. PNC-method analyzes parameters of probing laser radiation and PNC-spectrums of stimulated secondary radiations: backscattering and endogenous fluorescence of caries- involved bacteria. Ia-Ne laser ((lambda) equals632.8 nm, 1-2 mW) was used as a source of probing (stimulated) radiation. For registration of signals, received from intact and pathological teeth PDA-detector was applied. PNC-spectrums were processed by special algorithms, and were displayed on PC monitor. The method of laser integral fluorescence was used for comparison. In this case integral power of fluorescence of human teeth was measured. As a source of probing (stimulated) radiation diode lasers ((lambda) equals655 nm, 0.1 mW and 630 nm, 1 mW) and Ia-Na laser were applied. For registration of signals Si-photodetector was used. Integral power was shown in a digital indicator. Advantages and disadvantages of these methods are described in this research. It is disclosed that the method of laser integral power of fluorescence has the following characteristics: simplicity of construction and schema-technical decisions. However the method of PNC-spectral diagnostics are characterized by considerably more sensitivity in diagnostics of initial caries and capability to differentiate pathologies of various stages (for example, calculus/initial caries). Estimation of spectral characteristics of PNC-signals allows eliminating a number of drawbacks, which are character for detection by method of laser integral fluorescence (for instance, detection of fluorescent fillings, plagues, calculus, discolorations generally, amalgam, gold fillings as if it were caries).

  7. Diagnostics of PF-1000 Facility Operation and Plasma Concentration on the Basis of Spectral Measurements

    SciTech Connect

    Skladnik-Sadowska, E.; Malinowski, K.; Sadowski, M. J.; Scholz, M.; Tsarenko, A. V.

    2006-01-15

    The paper concerns the monitoring of high-current pulse discharges and the determination of the plasma concentration within the dense magnetized plasma by means of optical spectroscopy methods. In experiments with the large PF-1000 facility operated at IPPLM in Warsaw, Poland, attention was paid to the determination of the operational mode and electron concentration under different experimental conditions. To measure the visible radiation (VR) the use was made of the MECHELLE registered 900-spectrometer equipped with the CCD readout. The VR emission, observed at 65 deg. to the z-axis, originated from a part of the electrode surfaces, the collapsing current-sheath layer and the dense plasma pinch-region (40-50 mm from the electrode ends). Considerable differences were found in the optical spectra recorded for so-called 'good shots' and for cases of some failures. Estimates of the electron concentration, which were performed with different spectroscopic techniques, showed that it ranged from 5.56x1018 cm-3 to 4.8x1019 cm-3, depending on experimental conditions. The correlation of the fusion-neutron yield and the plasma density was proved.

  8. Instrumentation for noninvasive express-diagnostics bacteriophages and viruses by optical method

    NASA Astrophysics Data System (ADS)

    Moguilnaia, Tatiana A.; Andreev, Gleb I.; Agibalov, Andrey A.; Botikov, Andrey G.; Kosenkov, Evgeniy; Saguitova, Elena

    2004-03-01

    The theoretical and the experimental researches of spectra of absent-minded radiation in medium containing viruses were carried out. The information on spectra luminescence 31 viruses was written down.The new method the express - analysis of viruses in organism of the man was developed. It shall be mentioned that the proposed method of express diagnostics allows detection of infection agent in the organism several hours after infection. It makes it suitable for high efficient testing in blood services for detection and rejection of potential donors infected with such viruses as hepatitis, herpes, Epstein-Barre, cytomegalovirus, and immunodeficiency. Methods of serum diagnostics used for that purpose can detect antibodies to virus only 1-3 months after the person has been infected. The device for the express analysis of 31 viruses of the man was created.

  9. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    SciTech Connect

    Winniford, Michael D

    2013-02-08

    smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study

  10. Development and improvement of the operating diagnostics systems of NPO CKTI works for turbine of thermal and nuclear power plants

    NASA Astrophysics Data System (ADS)

    Kovalev, I. A.; Rakovskii, V. G.; Isakov, N. Yu.; Sandovskii, A. V.

    2016-03-01

    The work results on the development and improvement of the techniques, algorithms, and software-hardware of continuous operating diagnostics systems of rotating units and parts of turbine equipment state are presented. In particular, to ensure the full remote service of monitored turbine equipment using web technologies, the web version of the software of the automated systems of vibration-based diagnostics (ASVD VIDAS) was developed. The experience in the automated analysis of data obtained by ASVD VIDAS form the basis of the new algorithm of early detection of such dangerous defects as rotor deflection, crack in the rotor, and strong misalignment of supports. The program-technical complex of monitoring and measuring the deflection of medium pressure rotor (PTC) realizing this algorithm will alert the electric power plant staff during a deflection and indicate its value. This will give the opportunity to take timely measures to prevent the further extension of the defect. Repeatedly, recorded cases of full or partial destruction of shrouded shelves of rotor blades of the last stages of low-pressure cylinders of steam turbines defined the need to develop a version of the automated system of blade diagnostics (ASBD SKALA) for shrouded stages. The processing, analysis, presentation, and backup of data characterizing the mechanical state of blade device are carried out with a newly developed controller of the diagnostics system. As a result of the implementation of the works, the diagnosed parameters determining the operation security of rotating elements of equipment was expanded and the new tasks on monitoring the state of units and parts of turbines were solved. All algorithmic solutions and hardware-software implementations mentioned in the article were tested on the test benches and applied at some power plants.

  11. Disseminated histoplasmosis and AIDS: clinical aspects and diagnostic methods for early detection.

    PubMed

    Corti, M E; Cendoya, C A; Soto, I; Esquivel, P; Trione, N; Villafañe, M F; Corbera, K M; Helou, S; Negroni, R

    2000-03-01

    Disseminated histoplasmosis in AIDS patients is the focus of this paper. Cutaneous lesions are reported as a frequent clinical sign. Bone marrow aspiration and biopsy, blood cultures (lysis-centrifugation technique), bronchoalveolar lavage, and skin lesion scrapings are the most effective diagnostic methods. The identification of a specific antigen in blood and urine may be a rapid means of evaluation and follow-up of patients with this disease. PMID:10763544

  12. Electromagnetism, Optics and Lasers: Handbook of Coherent Domain Optical Methods, Biomedical Diagnostics, Environment and Material Science

    NASA Astrophysics Data System (ADS)

    Tuchin, Valery V.

    For the first time in one set of books, coherent-domain optical methods are discussed in the framework of various applications, which are characterized by a strong light scattering. A few chapters describe basic research c ontaining the updated results on coherent and polarized light non-destructive interactions with a scattering medium, in particular, diffraction, interference, and speckle formation at multiple scattering. These chapters allow for understanding coherent-domain diagnostic techniques presented in later chapters.

  13. Adaptation of LASCA method for diagnostics of malignant tumours in laboratory animals

    SciTech Connect

    Ul'yanov, S S; Laskavyi, V N; Glova, Alina B; Polyanina, T I; Ul'yanova, O V; Fedorova, V A; Ul'yanov, A S

    2012-05-31

    The LASCA method is adapted for diagnostics of malignant neoplasms in laboratory animals. Tumours are studied in mice of Balb/c inbred line after inoculation of cells of syngeneic myeloma cell line Sp.2/0 Ag.8. The appropriateness of using the tLASCA method in tumour investigations is substantiated; its advantages in comparison with the sLASCA method are demonstrated. It is found that the most informative characteristic, indicating the presence of a tumour, is the fractal dimension of LASCA images.

  14. Adaptation of LASCA method for diagnostics of malignant tumours in laboratory animals

    NASA Astrophysics Data System (ADS)

    Ul'yanov, S. S.; Laskavyi, V. N.; Glova, Alina B.; Polyanina, T. I.; Ul'yanova, O. V.; Fedorova, V. A.; Ul'yanov, A. S.

    2012-05-01

    The LASCA method is adapted for diagnostics of malignant neoplasms in laboratory animals. Tumours are studied in mice of Balb/c inbred line after inoculation of cells of syngeneic myeloma cell line Sp.2/0 — Ag.8. The appropriateness of using the tLASCA method in tumour investigations is substantiated; its advantages in comparison with the sLASCA method are demonstrated. It is found that the most informative characteristic, indicating the presence of a tumour, is the fractal dimension of LASCA images.

  15. Bayesian and maximum entropy methods for fusion diagnostic measurements with compact neutron spectrometers

    NASA Astrophysics Data System (ADS)

    Reginatto, Marcel; Zimbal, Andreas

    2008-02-01

    In applications of neutron spectrometry to fusion diagnostics, it is advantageous to use methods of data analysis which can extract information from the spectrum that is directly related to the parameters of interest that describe the plasma. We present here methods of data analysis which were developed with this goal in mind, and which were applied to spectrometric measurements made with an organic liquid scintillation detector (type NE213). In our approach, we combine Bayesian parameter estimation methods and unfolding methods based on the maximum entropy principle. This two-step method allows us to optimize the analysis of the data depending on the type of information that we want to extract from the measurements. To illustrate these methods, we analyze neutron measurements made at the PTB accelerator under controlled conditions, using accelerator-produced neutron beams. Although the methods have been chosen with a specific application in mind, they are general enough to be useful for many other types of measurements.

  16. Operator performance evaluation using multi criteria decision making methods

    NASA Astrophysics Data System (ADS)

    Rani, Ruzanita Mat; Ismail, Wan Rosmanira; Razali, Siti Fatihah

    2014-06-01

    Operator performance evaluation is a very important operation in labor-intensive manufacturing industry because the company's productivity depends on the performance of its operators. The aims of operator performance evaluation are to give feedback to operators on their performance, to increase company's productivity and to identify strengths and weaknesses of each operator. In this paper, six multi criteria decision making methods; Analytical Hierarchy Process (AHP), fuzzy AHP (FAHP), ELECTRE, PROMETHEE II, Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) and VlseKriterijumska Optimizacija I Kompromisno Resenje (VIKOR) are used to evaluate the operators' performance and to rank the operators. The performance evaluation is based on six main criteria; competency, experience and skill, teamwork and time punctuality, personal characteristics, capability and outcome. The study was conducted at one of the SME food manufacturing companies in Selangor. From the study, it is found that AHP and FAHP yielded the "outcome" criteria as the most important criteria. The results of operator performance evaluation showed that the same operator is ranked the first using all six methods.

  17. 94. DAM TAINTER GATE OPERATING MACHINERY METHOD OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    94. DAM - TAINTER GATE OPERATING MACHINERY - METHOD OF ATTACHING LIFTING CHAINS TO DRUMS OF HOIST - LAKESIDE TYPE (ML-4&5-55/34-FS), February 1938 - Upper Mississippi River 9-Foot Channel, Lock & Dam No. 4, Alma, Buffalo County, WI

  18. Dynamically balanced fuel nozzle and method of operation

    DOEpatents

    Richards, George A.; Janus, Michael C.; Robey, Edward H.

    2000-01-01

    An apparatus and method of operation designed to reduce undesirably high pressure oscillations in lean premix combustion systems burning hydrocarbon fuels are provided. Natural combustion and nozzle acoustics are employed to generate multiple fuel pockets which, when burned in the combustor, counteract the oscillations caused by variations in heat release in the combustor. A hybrid of active and passive control techniques, the apparatus and method eliminate combustion oscillations over a wide operating range, without the use of moving parts or electronics.

  19. Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellarator.

    PubMed

    Zhang, D; Burhenn, R; Koenig, R; Giannone, L; Grodzki, P A; Klein, B; Grosser, K; Baldzuhn, J; Ewert, K; Erckmann, V; Hirsch, M; Laqua, H P; Oosterbeek, J W

    2010-10-01

    A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but also from stray radiation of the nonabsorbed isotropic microwaves. This paper gives an overview of the technical problems encountered during the design work and the solutions to individual problems to meet the special requirements in W7-X, e.g., component thermal protection, detector offset thermal drift suppression, as well as a microwave shielding technique. PMID:21033996

  20. The role of ultrasound and nuclear medicine methods in the preoperative diagnostics of primary hyperparathyroidism

    PubMed Central

    Cacko, Marek; Królicki, Leszek

    2015-01-01

    Primary hyperparathyroidism (PH) represents one of the most common endocrine diseases. In most cases, the disorder is caused by parathyroid adenomas. Bilateral neck exploration has been a widely used treatment method for adenomas since the 20's of the twentieth century. In the last decade, however, it has been increasingly replaced by a minimally invasive surgical treatment. Smaller extent, shorter duration and lower complication rate of such a procedure are emphasized. Its efficacy depends on a precise location of parathyroid tissue during the preoperative imaging. Scintigraphy and ultrasound play a major role in the diagnostic algorithms. The efficacy of both methods has been repeatedly verified and compared. The still-current guidelines of the European Association of Nuclear Medicine (2009) emphasize the complementary role of scintigraphy and ultrasonography in the preoperative diagnostics in patients with primary hyperparathyroidism. At the same time, attempts are made to improve both these techniques by implementing new study protocols or innovative technologies. Publications have emerged in the recent years in the field of ultrasonography, whose authors pointed out the usefulness of elastography and contrast media. Nuclear medicine studies, on the other hand, focus mainly on the assessment of new radiotracers used in the positron emission tomography (PET). The aim of this article is to present, based on literature data, the possibilities of ultrasound and scintigraphy in the preoperative diagnostics in patients with primary hyperparathyroidism. Furthermore, the main directions in the development of imaging techniques in PH patients were evaluated. PMID:26807297

  1. The role of ultrasound and nuclear medicine methods in the preoperative diagnostics of primary hyperparathyroidism.

    PubMed

    Nieciecki, Michał; Cacko, Marek; Królicki, Leszek

    2015-12-01

    Primary hyperparathyroidism (PH) represents one of the most common endocrine diseases. In most cases, the disorder is caused by parathyroid adenomas. Bilateral neck exploration has been a widely used treatment method for adenomas since the 20's of the twentieth century. In the last decade, however, it has been increasingly replaced by a minimally invasive surgical treatment. Smaller extent, shorter duration and lower complication rate of such a procedure are emphasized. Its efficacy depends on a precise location of parathyroid tissue during the preoperative imaging. Scintigraphy and ultrasound play a major role in the diagnostic algorithms. The efficacy of both methods has been repeatedly verified and compared. The still-current guidelines of the European Association of Nuclear Medicine (2009) emphasize the complementary role of scintigraphy and ultrasonography in the preoperative diagnostics in patients with primary hyperparathyroidism. At the same time, attempts are made to improve both these techniques by implementing new study protocols or innovative technologies. Publications have emerged in the recent years in the field of ultrasonography, whose authors pointed out the usefulness of elastography and contrast media. Nuclear medicine studies, on the other hand, focus mainly on the assessment of new radiotracers used in the positron emission tomography (PET). The aim of this article is to present, based on literature data, the possibilities of ultrasound and scintigraphy in the preoperative diagnostics in patients with primary hyperparathyroidism. Furthermore, the main directions in the development of imaging techniques in PH patients were evaluated. PMID:26807297

  2. Method and Apparatus Providing Deception and/or Altered Operation in an Information System Operating System

    DOEpatents

    Cohen, Fred; Rogers, Deanna T.; Neagoe, Vicentiu

    2008-10-14

    A method and/or system and/or apparatus providing deception and/or execution alteration in an information system. In specific embodiments, deceptions and/or protections are provided by intercepting and/or modifying operation of one or more system calls of an operating system.

  3. [Forensic medical diagnostics of intra-vitality of the strangulation mark by morphological methods].

    PubMed

    Bogomolov, D V; Zbrueva, Yu V; Putintsev, V A; Denisova, O P

    2016-01-01

    The objective of the present study WaS to overview the current domestic and foreign literature concerning the up-to-date methods employed for the expert evaluation of intra-vitality of the strangulation mark. The secondary objective was to propose the new approaches for addressing this problem. The methods of expert diagnostics with a view to determining the time of infliction of injuries as exemplified by mechanical asphyxia are discussed. It is concluded that immunohistochemical and morphometric studies provide the most promising tools for the evaluation of intra-vitality of the strangulation mark for the purpose of forensic medical expertise. PMID:27358932

  4. Pirogow's Amputation: A Modification of the Operation Method

    PubMed Central

    Bueschges, M.; Muehlberger, T.; Mauss, K. L.; Bruck, J. C.; Ottomann, C.

    2013-01-01

    Introduction. Pirogow's amputation at the ankle presents a valuable alternative to lower leg amputation for patients with the corresponding indications. Although this method offers the ability to stay mobile without the use of a prosthesis, it is rarely performed. This paper proposes a modification regarding the operation method of the Pirogow amputation. The results of the modified operation method on ten patients were objectified 12 months after the operation using a patient questionnaire (Ankle Score). Material and Methods. We modified the original method by rotating the calcaneus. To fix the calcaneus to the tibia, Kirschner wire and a 3/0 spongiosa tension screw as well as a Fixateur externe were used. Results. 70% of those questioned who were amputated following the modified Pirogow method indicated an excellent or very good result in total points whereas in the control group (original Pirogow's amputation) only 40% reported excellent or very good result. In addition, the level of pain experienced one year after the completed operation showed different results in favour of the group being operated with the modified way. Furthermore, patients in both groups showed differences in radiological results, postoperative leg length difference, and postoperative mobility. Conclusion. The modified Pirogow amputation presents a valuable alternative to the original amputation method for patients with the corresponding indications. The benefits are found in the significantly reduced pain, difference in reduced radiological complications, the increase in mobility without a prosthesis, and the reduction of postoperative leg length difference. PMID:23606976

  5. Inversion methods for the measurements of MHD-like density fluctuations by Heavy Ion Beam Diagnostic

    NASA Astrophysics Data System (ADS)

    Malaquias, A.; Henriques, R. B.; Nedzelsky, I. S.

    2015-09-01

    We report here on the recent developments in the deconvolution of the path integral effects for the study of MHD pressure-like fluctuations measured by Heavy Ion Beam Diagnostic. In particular, we develop improved methods to account for and remove the path integral effect on the determination of the ionization generation factors, including the double ionization of the primary beam. We test the method using the HIBD simulation code which computes the real beam trajectories and attenuations due to electron impact ionization for any selected synthetic profiles of plasma current, plasma potential, electron temperature and density. Simulations have shown the numerical method to be highly effective in ISTTOK within an overall accuracy of a few percent (< 3%). The method here presented can effectively reduce the path integral effects and may serve as the basis to develop improved retrieving techniques for plasma devices working even in higher density ranges. The method is applied to retrieve the time evolution and spatial structure of m=1 and m=2 modes. The 2D MHD mode-like structure is reconstructed by means of a spatial projection of all 1D measurements obtained during one full rotation of the mode. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  6. 37 CFR 203.4 - Methods of operation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Methods of operation. 203.4 Section 203.4 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES FREEDOM OF INFORMATION ACT: POLICIES AND PROCEDURES Procedures § 203.4 Methods...

  7. Engine systems and methods of operating an engine

    DOEpatents

    Scotto, Mark Vincent

    2015-08-25

    One embodiment of the present invention is a unique method for operating an engine. Another embodiment is a unique engine system. Other embodiments include apparatuses, systems, devices, hardware, methods, and combinations for engines and engine systems. Further embodiments, forms, features, aspects, benefits, and advantages of the present application will become apparent from the description and figures provided herewith.

  8. Personality Assessment in the Diagnostic Manuals: On Mindfulness, Multiple Methods, and Test Score Discontinuities

    PubMed Central

    Bornstein, Robert F.

    2015-01-01

    Recent controversies have illuminated the strengths and limitations of different frameworks for conceptualizing personality pathology (e.g., trait perspectives, categorical models), and stimulated debate regarding how best to diagnose personality disorders (PDs) in DSM-5, and in other diagnostic systems (i.e., the International Classification of Diseases, the Psychodynamic Diagnostic Manual). In this article I argue that regardless of how PDs are conceptualized and which diagnostic system is employed, multi-method assessment must play a central role in PD diagnosis. By complementing self-reports with evidence from other domains (e.g., performance-based tests), a broader range of psychological processes are engaged in the patient, and the impact of self-perception and self-presentation biases may be better understood. By providing the assessor with evidence drawn from multiple modalities, some of which provide converging patterns and some of which yield divergent results, the assessor is compelled to engage this evidence more deeply. The mindful processing that ensues can help minimize the deleterious impact of naturally occurring information processing bias and distortion on the part of the clinician (e.g., heuristics, attribution errors), bringing greater clarity to the synthesis and integration of assessment data. PMID:25856565

  9. Surgical extraction of lower third molars: diagnostic tests and operative technique in the prevention of inferior alveolar nerve injury. Case study

    PubMed Central

    MELEO, D.; PACIFICI, L.

    2009-01-01

    SUMMARY Increased knowledge and technical refinement have broadened the limits of outpatient oral surgery; however, these changes have at the same time led to a greater number of complications and poor outcomes and, accordingly, to legal action for professional responsibility. Oral surgery represents 10% of all actions, and almost all of these are attributable to exodontic surgery, of which around a third are related to inferior alveolar nerve injury following the extraction of lower third molars. The aim of this case study is to suggest operative technical strategies in accordance with a correct clinical-diagnostic pathway in order to prevent neurological complications involving the inferior alveolar nerve subsequent to lower third molar extraction. Cases should be carefully selected and surgical intervention undertaken solely when genuinely necessary. The patient should be informed of the risks, the methods and the possible results of the treatment. These are the bases for correct indication, along with a sufficient diagnostic path and a good level of communication between operator and patient. PMID:23285341

  10. BEACON: An application of nodal methods for operational support

    SciTech Connect

    Boyd, W.A.; Nguyen, T.Q. )

    1992-01-01

    A practical application of nodal methods is on-line plant operational support. However, to enable plant personnel to take full advantage of a nodal model to support plant operations, (a) a core nodal model must always be up to date with the current core history and conditions, (b) the nodal methods must be fast enough to allow numerous core calculations to be performed in minutes to support engineering decisions, and (c) the system must be easily accessible to engineering personnel at the reactor, their offices, or any other location considered appropriate. A core operational support package developed by Westinghouse called BEACON (best estimate analysis of core operations - nuclear) has been installed at several plants. Results from these plants and numerous in-core flux maps analyzed have demonstrated the accuracy of the model and the effectiveness of the methodology

  11. Support Operators Method for the Diffusion Equation in Multiple Materials

    SciTech Connect

    Winters, Andrew R.; Shashkov, Mikhail J.

    2012-08-14

    A second-order finite difference scheme for the solution of the diffusion equation on non-uniform meshes is implemented. The method allows the heat conductivity to be discontinuous. The algorithm is formulated on a one dimensional mesh and is derived using the support operators method. A key component of the derivation is that the discrete analog of the flux operator is constructed to be the negative adjoint of the discrete divergence, in an inner product that is a discrete analog of the continuum inner product. The resultant discrete operators in the fully discretized diffusion equation are symmetric and positive definite. The algorithm is generalized to operate on meshes with cells which have mixed material properties. A mechanism to recover intermediate temperature values in mixed cells using a limited linear reconstruction is introduced. The implementation of the algorithm is verified and the linear reconstruction mechanism is compared to previous results for obtaining new material temperatures.

  12. Express diagnostics of intact and pathological dental hard tissues by optical PNC method

    NASA Astrophysics Data System (ADS)

    Masychev, Victor I.; Alexandrov, Michail T.

    2000-03-01

    The results of hard tooth tissues research by the optical PNC- method in experimental and clinical conditions are presented. In the experiment under 90 test-sample of tooth slices with thickness about 1 mm (enamel, dentine and cement) were researched. The results of the experiment were processed by the method of correlation analyze. Clinical researches were executed on teeth of 210 patients. The regions of tooth tissue diseases with initial, moderate and deep caries were investigated. Spectral characteristics of intact and pathologically changed tooth tissues are presented and their peculiar features are discussed. The results the optical PNC- method application while processing tooth carious cavities are presented in order to estimate efficiency of the mechanical and antiseptic processing of teeth. It is revealed that the PNC-method can be used as for differential diagnostics of a degree dental carious stage, as for estimating of carefulness of tooth cavity processing before filling.

  13. Design and operation of the multipulse Thomson scattering diagnostic on DIII-D

    SciTech Connect

    Carlstrom, T.N.; Campbell, G.L.; DeBoo, J.C.; Evanko, R.; Greenfield, C.M.; Haskovec, J.; Hsieh, C.L.; McKee, E.; Snider, R.T.; Stockdale, R.; Trost, P.K.; Thomas, M.P.; Evans, J.

    1992-03-01

    This paper describes the design and operation of a 40 spatial channel Thomson scattering system that uses multiple 20 Hz Nd:YAG lasers to measure the electron temperature and density profiles periodically throughout an entire plasma discharge. As many as eight lasers may be fired alternately for an average measurement frequency of 160 Hz, or they may be fired in rapid succession (< 10 kHz), producing a burst of pulses for measuring transient events. The high spatial resolution (1.3 cm) and wide dynamic range (10 eV to 20 keV) enable this system to resolve large electron density and temperature gradients formed at the plasma edge and in the scrape-off-layer during H-mode operation. These features provide a formidable tool for studying L-H transitions, edge localized modes (ELMs), beta limits, transport, and disruptions in an efficient manner suitable for large tokamak operation where shot-to-shot scans are impractical. The scattered light is dispersed by interference filter polychromators and detected by silicon avalanche photodiodes. Laser control and data acquisition are performed in real-time by a VME based microcomputer. Data analysis is performed by a MicroVAX 3400. Additional features of this system include real-time analysis capability, full statistical treatment of error bars based on the measured background light, and laser beam quality and alignment monitoring during plasma operation. Results of component testing, calibration, plasma operation, and error analysis are presented.

  14. [Improved method of operative treatment of trigeminal neuralgia].

    PubMed

    Karshiev, Kh K; Mukhammidiev, K R; Khudarganov, U O

    2008-01-01

    In 93 patients being treated in maxillofacial surgery unit partial removal of trigeminus with vessels; in 92 patients the operation was followed by simultaneous decortication of the foramen walls or partial decortication of the mandibular canal with simultaneous blocking of them by autografts. This method proved to be perspective and reliable inasmuch as after such operations paroxysm of pain were put an end to for the period of time from 2 to 8.6 years. PMID:19156104

  15. Calculation of infrared system operating distance by spectral bisection method

    NASA Astrophysics Data System (ADS)

    Zhao, Yu; Wu, Ping; Sun, Wenfang

    2014-03-01

    During the transmission of infrared radiation, the atmospheric transmittance could be a complex parameter due to the absorbing and scattering of atmosphere, as well as the influences from the environment and transmission distance. With the help of a spectral bisection method, a new assessing formula and solution is raised by calculating the operating distance of infrared system. In the small segments, MODTRAN can be used to figure out the percentage of penetration, which is called by advanced program, so as to get the infrared radiation in those segments. The calculated data of the segments were summed up and used to calculate the operating distance of the infrared system. Compared with the conventional calculation methods that the transmittance was used as a constant or a average, The calculation precise of the operating distance is highly increased by this method the results of all small segments by comparing with the traditional methods. The whole computing process becomes more clear and effective by taking the influences from visibility of atmosphere, altitude, targets zenith angle and spatial frequency into consideration, and by building an instant monitoring system of the operating distance. The final computing result and real effecting distance are based on the general simulation for penetration rate and the tendency of operating distance in all conditions.

  16. New diagnostic methods for laser plasma- and microwave-enhanced combustion.

    PubMed

    Miles, Richard B; Michael, James B; Limbach, Christopher M; McGuire, Sean D; Chng, Tat Loon; Edwards, Matthew R; DeLuca, Nicholas J; Shneider, Mikhail N; Dogariu, Arthur

    2015-08-13

    The study of pulsed laser- and microwave-induced plasma interactions with atmospheric and higher pressure combusting gases requires rapid diagnostic methods that are capable of determining the mechanisms by which these interactions are taking place. New rapid diagnostics are presented here extending the capabilities of Rayleigh and Thomson scattering and resonance-enhanced multi-photon ionization (REMPI) detection and introducing femtosecond laser-induced velocity and temperature profile imaging. Spectrally filtered Rayleigh scattering provides a method for the planar imaging of temperature fields for constant pressure interactions and line imaging of velocity, temperature and density profiles. Depolarization of Rayleigh scattering provides a measure of the dissociation fraction, and multi-wavelength line imaging enables the separation of Thomson scattering from Rayleigh scattering. Radar REMPI takes advantage of high-frequency microwave scattering from the region of laser-selected species ionization to extend REMPI to atmospheric pressures and implement it as a stand-off detection method for atomic and molecular species in combusting environments. Femtosecond laser electronic excitation tagging (FLEET) generates highly excited molecular species and dissociation through the focal zone of the laser. The prompt fluorescence from excited molecular species yields temperature profiles, and the delayed fluorescence from recombining atomic fragments yields velocity profiles. PMID:26170432

  17. White-Nose Syndrome Disease Severity and a Comparison of Diagnostic Methods.

    PubMed

    McGuire, Liam P; Turner, James M; Warnecke, Lisa; McGregor, Glenna; Bollinger, Trent K; Misra, Vikram; Foster, Jeffrey T; Frick, Winifred F; Kilpatrick, A Marm; Willis, Craig K R

    2016-03-01

    White-nose syndrome is caused by the fungus Pseudogymnoascus destructans and has killed millions of hibernating bats in North America but the pathophysiology of the disease remains poorly understood. Our objectives were to (1) assess non-destructive diagnostic methods for P. destructans infection compared to histopathology, the current gold-standard, and (2) to evaluate potential metrics of disease severity. We used data from three captive inoculation experiments involving 181 little brown bats (Myotis lucifugus) to compare histopathology, quantitative PCR (qPCR), and ultraviolet fluorescence as diagnostic methods of P. destructans infection. To assess disease severity, we considered two histology metrics (wing area with fungal hyphae, area of dermal necrosis), P. destructans fungal load (qPCR), ultraviolet fluorescence, and blood chemistry (hematocrit, sodium, glucose, pCO2, and bicarbonate). Quantitative PCR was most effective for early detection of P. destructans, while all three methods were comparable in severe infections. Correlations among hyphae and necrosis scores, qPCR, ultraviolet fluorescence, blood chemistry, and hibernation duration indicate a multi-stage pattern of disease. Disruptions of homeostasis occurred rapidly in late hibernation. Our results provide valuable information about the use of non-destructive techniques for monitoring, and provide novel insight into the pathophysiology of white-nose syndrome, with implications for developing and implementing potential mitigation strategies. PMID:26957435

  18. New diagnostic methods for laser plasma- and microwave-enhanced combustion

    PubMed Central

    Miles, Richard B; Michael, James B; Limbach, Christopher M; McGuire, Sean D; Chng, Tat Loon; Edwards, Matthew R; DeLuca, Nicholas J; Shneider, Mikhail N; Dogariu, Arthur

    2015-01-01

    The study of pulsed laser- and microwave-induced plasma interactions with atmospheric and higher pressure combusting gases requires rapid diagnostic methods that are capable of determining the mechanisms by which these interactions are taking place. New rapid diagnostics are presented here extending the capabilities of Rayleigh and Thomson scattering and resonance-enhanced multi-photon ionization (REMPI) detection and introducing femtosecond laser-induced velocity and temperature profile imaging. Spectrally filtered Rayleigh scattering provides a method for the planar imaging of temperature fields for constant pressure interactions and line imaging of velocity, temperature and density profiles. Depolarization of Rayleigh scattering provides a measure of the dissociation fraction, and multi-wavelength line imaging enables the separation of Thomson scattering from Rayleigh scattering. Radar REMPI takes advantage of high-frequency microwave scattering from the region of laser-selected species ionization to extend REMPI to atmospheric pressures and implement it as a stand-off detection method for atomic and molecular species in combusting environments. Femtosecond laser electronic excitation tagging (FLEET) generates highly excited molecular species and dissociation through the focal zone of the laser. The prompt fluorescence from excited molecular species yields temperature profiles, and the delayed fluorescence from recombining atomic fragments yields velocity profiles. PMID:26170432

  19. Combined Use of Cytogenetic and Molecular Methods in Prenatal Diagnostics of Chromosomal Abnormalities

    PubMed Central

    Stomornjak-Vukadin, Meliha; Kurtovic-Basic, Ilvana; Mehinovic, Lejla; Konjhodzic, Rijad

    2015-01-01

    Aim: The aim of prenatal diagnostics is to provide information of the genetic abnormalities of the fetus early enough for the termination of pregnancy to be possible. Chromosomal abnormalities can be detected in an unborn child through the use of cytogenetic, molecular- cytogenetic and molecular methods. In between them, central spot is still occupied by cytogenetic methods. In cases where use of such methods is not informative enough, one or more molecular cytogenetic methods can be used for further clarification. Combined use of the mentioned methods improves the quality of the final findings in the diagnostics of chromosomal abnormalities, with classical cytogenetic methods still occupying the central spot. Material and methods: Conducted research represent retrospective-prospective study of a four year period, from 2008 through 2011. In the period stated, 1319 karyotyping from amniotic fluid were conducted, along with 146 FISH analysis. Results: Karyotyping had detected 20 numerical and 18 structural aberrations in that period. Most common observed numerical aberration were Down syndrome (75%), Klinefelter syndrome (10%), Edwards syndrome, double Y syndrome and triploidy (5% each). Within observed structural aberrations more common were balanced chromosomal aberrations then non balanced ones. Most common balanced structural aberrations were as follows: reciprocal translocations (60%), Robertson translocations (13.3%), chromosomal inversions, duplications and balanced de novo chromosomal rearrangements (6.6% each). Conclusion: With non- balanced aberrations observed in the samples of amniotic fluid, non- balanced translocations, deletions and derived chromosomes were equally represented. Number of detected aneuploidies with FISH, prior to obtaining results with karyotyping, were 6. PMID:26005269

  20. DIAGNOSTIC EVALUATION OF AIR QUALITY MODELS USING ADVANCED METHODS WITH SPECIALIZED OBSERVATIONS OF SELECTED AMBIENT SPECIES -PART II

    EPA Science Inventory

    This is Part 2 of "Diagnostic Evaluation of Air Quality Models Using Advanced Methods with Specialized Observations of Selected Ambient Species". A limited field campaign to make specialized observations of selected ambient species using advanced and innovative instrumentation f...

  1. Evaluation of the Effect of Fluctuation of Absolute Value for Diagnostic Accuracy of Fatigue Crack Monitoring Via Statistical Diagnostic Method Using Correlation between Sensors

    NASA Astrophysics Data System (ADS)

    Iwasaki, Atsushi; Morimoto, Akihiro; Yatomi, Masataka; Kimura, Tadashi

    This research is about improvement of the diagnostic accuracy of the fatigue crack monitoring via the statistical diagnostic method. Our research group proposes an unsupervised damage diagnostic method named SI-F method which diagnoses the damage from detecting the change of correlation between sensors caused by the initiation or propagation of the damage via the statistical evaluation. By the method, correlation between sensors is identified by using the response surface and the change of them is statistically investigated with the F-test. To identify the crack length by the method, identification about the relation between the crack length and the F0 statistic is required. Then in this research, to evaluate effect of the regression error, the noise magnitude and the fluctuation of the external force to the relation, numerical simulation was conducted. For the simulation, two sets of data, one with constant load and one with variable load, are generated and compared. And the applicability of the result of the simulation is experimentally investigated. Finally, the results indicate that the F0 affected by the regression error and the noise magnitude but not affected by the external force.

  2. Systems and methods for analyzing building operations sensor data

    SciTech Connect

    Mezic, Igor; Eisenhower, Bryan A.

    2015-05-26

    Systems and methods are disclosed for analyzing building sensor information and decomposing the information therein to a more manageable and more useful form. Certain embodiments integrate energy-based and spectral-based analysis methods with parameter sampling and uncertainty/sensitivity analysis to achieve a more comprehensive perspective of building behavior. The results of this analysis may be presented to a user via a plurality of visualizations and/or used to automatically adjust certain building operations. In certain embodiments, advanced spectral techniques, including Koopman-based operations, are employed to discern features from the collected building sensor data.

  3. Method for operating a combustor in a fuel cell system

    DOEpatents

    Clingerman, Bruce J.; Mowery, Kenneth D.

    2002-01-01

    In one aspect, the invention provides a method of operating a combustor to heat a fuel processor to a desired temperature in a fuel cell system, wherein the fuel processor generates hydrogen (H.sub.2) from a hydrocarbon for reaction within a fuel cell to generate electricity. More particularly, the invention provides a method and select system design features which cooperate to provide a start up mode of operation and a smooth transition from start-up of the combustor and fuel processor to a running mode.

  4. Centrifuge-operated specimen staining method and apparatus

    NASA Technical Reports Server (NTRS)

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  5. Synchronized operation by field programmable gate array based signal controller for the Thomson scattering diagnostic system in KSTAR

    SciTech Connect

    Lee, W. R.; Park, M. K.; Lee, J. H.; Kim, H. S.; Kim, K. H.

    2012-09-15

    The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.

  6. Investigation of opportunities of the optical non-invasive diagnostics method for the blood sugar control

    NASA Astrophysics Data System (ADS)

    Lastovskaia, Elena A.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.

    2015-03-01

    The relevance of noninvasive method for determining the blood sugar is caused by necessity of regular monitoring of glucose levels in diabetic patients blood. Traditional invasive method is painful, because it requires a finger pricking. Despite the active studies in the field of non-invasive medical diagnostics, to date the painless and inexpensive instrument for blood sugar control for personal use doesn't exist. It's possible to measure the concentration of glucose in the blood with help of spectrophotometry method. It consists of registering and analyzing the spectral characteristics of the radiation which missed, reflected or absorbed by the object. The authors proposed a measuring scheme for studying the spectral characteristics of the radiation, missed by earlobe. Ultra-violet, visible and near infrared spectral ranges are considered. The paper presents the description of construction and working principles of the proposed special retaining clip and results of experiment with real patient.

  7. Fluorescent-spectroscopic and imaging methods of investigations for diagnostics of head and neck tumors and control of PDT

    NASA Astrophysics Data System (ADS)

    Edinak, N. E.; Chental, Victor V.; Komov, D.; Vaculovskaya, E.; Tabolinovskaya, T. D.; Abdullin, N. A.; Pustynsky, I.; Chatikhin, V.; Loschenov, Victor B.; Meerovich, Gennady A.; Stratonnikov, A. A.; Linkov, Kirill G.; Agafonov, Vladimir I.; Zuravleva, V.; Lukjanets, E.

    1996-01-01

    Methodics of PDT control and fluorescent-spectroscopic diagnostic of head and neck tumors and mammary gland cancer (nodular) with the use of Kr, He-Ne and semiconductor lasers and photosensitizer (PS) -- Al phtalocyanin (Photosense) are discussed. The results show that applied diagnostic methods permit us not only to identify the topology and malignancy of a tumor but also to correct PDT process directly during irradiation.

  8. Mammary carcinoma – current diagnostic methods and symptomatology in imaging studies

    PubMed Central

    Popiel, Monika; Mróz-Klimas, Danuta; Kasprzak, Renata; Furmanek, Mariusz

    2012-01-01

    Summary Breast cancer is the most common neoplasm of the female population and its incidence is constantly rising. Social campaigns educating the public about the importance of the problem have been conducted for the past several years. Women are encouraged to self-examine on a monthly basis. Women aged 50–69 years can have an x-ray mammography performed once every 2 years as part of a prophylactic screening program. Ultrasound studies or MR mammography are adjuvant or, in some cases, alternative to x-ray mammography. Nuclear medicine techniques with application of oncophilic markers and receptor studies (this publication will not cover nuclear medicine methods) are not routinely used. Other techniques, such as computed tomography and conventional radiography are of no significance in the diagnostics of mammary cancer. However, together with isotopic methods, they are helpful in staging of the disease. X-ray mammography is, up to date, the only method with proven value in decreasing mortality. It is also the best available method for visualization of microcalicifications. Ultrasound examination is complementary to x-ray mammography as it is a cheap, easily available method of imaging mammary glands with higher glandular tissue content. It is also the most commonly used modality aiding in targeted biopsy of mammary gland. To date, MR mammography, characterized by the highest sensitivity in cancer diagnostics, remained a method reserved for “special tasks”. MR is used for prophylaxis mainly in a population of women with particularly high risk of the disease and in cases where x-ray and ultrasound examinations are insufficient. Picture of mammary carcinoma in imaging studies is heterogeneous. However, it most often presents as an irregularly demarcated mass. Moreover, each modality can aid in visualization of additional features of a lesion such as typical shape of microcalcifications in x-ray mammography, characteristic pattern of contrast enhancement in MR

  9. Evaluation of Three Rapid Diagnostic Methods for Direct Identification of Microorganisms in Positive Blood Cultures

    PubMed Central

    Martinez, Raquel M.; Bauerle, Elizabeth R.; Fang, Ferric C.

    2014-01-01

    The identification of organisms from positive blood cultures generally takes several days. However, recently developed rapid diagnostic methods offer the potential for organism identification within only a few hours of blood culture positivity. In this study, we evaluated the performance of three commercial methods to rapidly identify organisms directly from positive blood cultures: QuickFISH (AdvanDx, Wolburn, MA), Verigene Gram-Positive Blood Culture (BC-GP; Nanosphere, Northbrook, IL), and matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) with Sepsityper processing (Bruker Daltonics, Billerica, MA). A total of 159 blood cultures (VersaTREK Trek Diagnostic Systems, Cleveland, OH) positive for Gram-positive and Gram-negative bacteria as well as yeast were analyzed with QuickFISH and MALDI-TOF MS. In all, 102 blood cultures were analyzed using the BC-GP assay. For monomicrobial cultures, we observed 98.0% concordance with routine methods for both QuickFISH (143/146) and the BC-GP assay (93/95). MALDI-TOF MS demonstrated 80.1% (117/146) and 87.7% (128/146) concordance with routine methods to the genus and species levels, respectively. None of the methods tested were capable of consistently identifying polymicrobial cultures in their entirety or reliably differentiating Streptococcus pneumoniae from viridans streptococci. Nevertheless, the methods evaluated in this study are convenient and accurate for the most commonly encountered pathogens and have the potential to dramatically reduce turnaround time for the provision of results to the treating physician. PMID:24808235

  10. Approximate iterative operator method for potential-field downward continuation

    NASA Astrophysics Data System (ADS)

    Tai, Zhenhua; Zhang, Fengxu; Zhang, Fengqin; Hao, Mengcheng

    2016-05-01

    An approximate iterative operator method in wavenumber domain was proposed to improve the stability and accuracy of downward continuation of potential fields measured from the ground surface, marine or airborne. Firstly, the generalized iterative formula of downward continuation is derived in wavenumber domain; then, the transformational relationship between horizontal second-order partial derivatives and continuation is derived based on the Taylor series and Laplace equation, to obtain an approximate operator. By introducing this operator to the generalized iterative formula, a rapid algorithm is developed for downward continuation. The filtering and convergence characteristics of this method are analyzed for the purpose of estimating the optimal interval of number of iterations. We demonstrate the proposed method on synthetic data, and the results validate the flexibility of the proposed method. At last, we apply the proposed method to real data, and the results show the proposed method can enhance gravity anomalies generated by concealed orebodies. And in the contour obtained by making our proposed method results continue upward to measured level, the numerical results have approximate distribution and amplitude with original anomalies.

  11. Molecular Diagnostics for Lassa Fever at Irrua Specialist Teaching Hospital, Nigeria: Lessons Learnt from Two Years of Laboratory Operation

    PubMed Central

    Hass, Meike; Gabriel, Martin; Ölschläger, Stephan; Becker-Ziaja, Beate; Folarin, Onikepe; Phelan, Eric; Ehiane, Philomena E.; Ifeh, Veritas E.; Uyigue, Eghosasere A.; Oladapo, Yemisi T.; Muoebonam, Ekene B.; Osunde, Osagie; Dongo, Andrew; Okokhere, Peter O.; Okogbenin, Sylvanus A.; Momoh, Mojeed; Alikah, Sylvester O.; Akhuemokhan, Odigie C.; Imomeh, Peter; Odike, Maxy A. C.; Gire, Stephen; Andersen, Kristian; Sabeti, Pardis C.; Happi, Christian T.; Akpede, George O.; Günther, Stephan

    2012-01-01

    Background Lassa fever is a viral hemorrhagic fever endemic in West Africa. However, none of the hospitals in the endemic areas of Nigeria has the capacity to perform Lassa virus diagnostics. Case identification and management solely relies on non-specific clinical criteria. The Irrua Specialist Teaching Hospital (ISTH) in the central senatorial district of Edo State struggled with this challenge for many years. Methodology/Principal Findings A laboratory for molecular diagnosis of Lassa fever, complying with basic standards of diagnostic PCR facilities, was established at ISTH in 2008. During 2009 through 2010, samples of 1,650 suspected cases were processed, of which 198 (12%) tested positive by Lassa virus RT-PCR. No remarkable demographic differences were observed between PCR-positive and negative patients. The case fatality rate for Lassa fever was 31%. Nearly two thirds of confirmed cases attended the emergency departments of ISTH. The time window for therapeutic intervention was extremely short, as 50% of the fatal cases died within 2 days of hospitalization—often before ribavirin treatment could be commenced. Fatal Lassa fever cases were older (p = 0.005), had lower body temperature (p<0.0001), and had higher creatinine (p<0.0001) and blood urea levels (p<0.0001) than survivors. Lassa fever incidence in the hospital followed a seasonal pattern with a peak between November and March. Lassa virus sequences obtained from the patients originating from Edo State formed—within lineage II—a separate clade that could be further subdivided into three clusters. Conclusions/Significance Lassa fever case management was improved at a tertiary health institution in Nigeria through establishment of a laboratory for routine diagnostics of Lassa virus. Data collected in two years of operation demonstrate that Lassa fever is a serious public health problem in Edo State and reveal new insights into the disease in hospitalized patients. PMID:23029594

  12. Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Hwan; Hong, Suk-Ho; Park, Il-Seo; Lee, Hyo-Chang; Kang, Hyun-Ju; Chung, Chin-Wook

    2015-12-01

    Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method.

  13. Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method.

    PubMed

    Kim, Dong-Hwan; Hong, Suk-Ho; Park, Il-Seo; Lee, Hyo-Chang; Kang, Hyun-Ju; Chung, Chin-Wook

    2015-12-01

    Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method. PMID:26724028

  14. Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method

    SciTech Connect

    Kim, Dong-Hwan; Hong, Suk-Ho; Park, Il-Seo; Lee, Hyo-Chang; Kang, Hyun-Ju; Chung, Chin-Wook

    2015-12-15

    Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method.

  15. An improved method for estimating the entrance exposure in diagnostic radiographic examinations.

    PubMed

    Zamenhof, R G; Shahabi, S; Morgan, H T

    1987-09-01

    There is currently a widespread consensus on the importance of monitoring patient radiation exposures during radiographic examinations. Diagnostic facilities under federal jurisdiction already legislate maximum patient exposure limits for various diagnostic radiologic examinations, while an increasing number of state legislatures have instituted such regulations. Compliance requires that institutions be capable of assessing each patient's entrance exposures. A method is proposed that would facilitate the acquisition of such patient exposure information in a relatively straightforward and accurate manner, requiring a minimum number of measurements and access to a suitable programmable calculator. A standardized set of exposure measurements obtained on an accurately calibrated three-phase radiographic unit has been fitted by an analytic function. The average accuracy of the fit between the limits of 40-140 kVp and 2.5- to 6.0-mm aluminum filtration was 0.3%. The concept of linear scaling was employed to allow the analytic function to accurately reproduce the exposure outputs of different radiographic units. Validation experiments on patients indicated that an overall accuracy of 10% can be expected when using well-calibrated radiographic equipment. The method described permits institutions to verify their compliance with federal and/or state regulations and to confirm that their radiation exposures are consistent with national averages. PMID:3497556

  16. BREAST: a novel method to improve the diagnostic efficacy of mammography

    NASA Astrophysics Data System (ADS)

    Brennan, P. C.; Tapia, K.; Ryan, J.; Lee, W.

    2013-03-01

    High quality breast imaging and accurate image assessment are critical to the early diagnoses, treatment and management of women with breast cancer. Breast Screen Reader Assessment Strategy (BREAST) provides a platform, accessible by researchers and clinicians world-wide, which will contain image data bases, algorithms to assess reader performance and on-line systems for image evaluation. The platform will contribute to the diagnostic efficacy of breast imaging in Australia and beyond on two fronts: reducing errors in mammography, and transforming our assessment of novel technologies and techniques. Mammography is the primary diagnostic tool for detecting breast cancer with over 800,000 women X-rayed each year in Australia, however, it fails to detect 30% of breast cancers with a number of missed cancers being visible on the image [1-6]. BREAST will monitor the mistakes, identify reasons for mammographic errors, and facilitate innovative solutions to reduce error rates. The BREAST platform has the potential to enable expert assessment of breast imaging innovations, anywhere in the world where experts or innovations are located. Currently, innovations are often being assessed by limited numbers of individuals who happen to be geographically located close to the innovation, resulting in equivocal studies with low statistical power. BREAST will transform this current paradigm by enabling large numbers of experts to assess any new method or technology using our embedded evaluation methods. We are confident that this world-first system will play an important part in the future efficacy of breast imaging.

  17. [Clinical usefulness of diagnostic methods for human papilloma virus dependent lesions].

    PubMed

    Suwalska, Anna; Owczarek, Witold; Fiedor, Piotr

    2014-02-01

    Persistent infection of Human Papilloma Virus (HPV) is confirmed necessary factor for development of cervical cancer and anogenital neoplasia. DNA HPV is detected in 96% of cervical cancer, 40% of vulvar and vaginal cancer, 90% of anal cancer and 26% of oral cavity cancer cases in general population. The most common high-risk HPV types observed in anogenital intraepithelial neoplasia or anogenital cancer are HPV 16, 18 and 45. Numerous diagnostic methods of detection of HPV infection and lesions causes by persistent HPV infection are widely used. Epidemiological data reveals correlation of incidence and mortality reduction due to cervical cancer and consequent prosecution and improvement of screening programmes based on morphological assessment of exfoliative smears. In last decade some limitations of conventional smear method were pointed out and a new diagnostic techniques were introduced: liquid-based cytology and HPV DNA testing. Combination of cytological examination and HPV DNA testing seems to be optimal solution to be introduced in large population because of combining high sensitivity of molecular test with high specificity of cytological smear. PMID:24720112

  18. 12 CFR 1102.303 - Organization and methods of operation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Organization and methods of operation. 1102.303 Section 1102.303 Banks and Banking FEDERAL FINANCIAL INSTITUTIONS EXAMINATION COUNCIL APPRAISER REGULATION... System, Federal Deposit Insurance Corporation, Office of the Comptroller of the Currency, National...

  19. Prediction of Preclinical Operative Dentistry Performance in Two Instructional Methods.

    ERIC Educational Resources Information Center

    Boyd, Marcia; And Others

    1980-01-01

    The accuracy of manual and academic variables in predicting preclinical operative technique was evaluated. Correlations were low, but significant using the Perceptual Motor Ability Test (PMAT) of the Dental Admission Test. Students with low or average two-dimension scores on the PMAT benefited from an alternate teaching method. (JSR)

  20. Daily Fill Factor Variation as a Diagnostic Probe of Multijunction Concentrator Systems During Outdoor Operation

    SciTech Connect

    McMahon, W. E.; Emery, K. E.; Friedman, D. J.; Ottoson, L.; Young, M. S.; Ward, J. S.; Kramer, C. M.; Duda, A.; Kurtz, S.

    2007-01-01

    The work presented here is for GaInP2/GaAs tandem cells, but the conclusions are equally valid for GaInP2/GaAs/Ge triple-junction cells. Optimizing a concentrator system which uses multijunction solar cells is challenging because: (a) the conditions are variable, so the solar cells rarely operate under optimal conditions and (b) the conditions are not controlled, so any design problems are difficult to characterize. Any change in the spectral content of direct-beam sunlight as it passes through the concentrator optics is of particular interest, as it can reduce the performance of multijunction cells and is difficult to characterize.

  1. Bayesian and maximum entropy methods for fusion diagnostic measurements with compact neutron spectrometers.

    PubMed

    Reginatto, Marcel; Zimbal, Andreas

    2008-02-01

    In applications of neutron spectrometry to fusion diagnostics, it is advantageous to use methods of data analysis which can extract information from the spectrum that is directly related to the parameters of interest that describe the plasma. We present here methods of data analysis which were developed with this goal in mind, and which were applied to spectrometric measurements made with an organic liquid scintillation detector (type NE213). In our approach, we combine Bayesian parameter estimation methods and unfolding methods based on the maximum entropy principle. This two-step method allows us to optimize the analysis of the data depending on the type of information that we want to extract from the measurements. To illustrate these methods, we analyze neutron measurements made at the PTB accelerator under controlled conditions, using accelerator-produced neutron beams. Although the methods have been chosen with a specific application in mind, they are general enough to be useful for many other types of measurements. PMID:18315297

  2. Crystallo-optic diagnostics method of the soft laser-induced effects in biological fluids

    NASA Astrophysics Data System (ADS)

    Skopinov, S. A.; Yakovleva, S. V.

    1991-05-01

    Presently, it is well known that individual cells"2 and higher organisms3'4 exhibit a marked response to soft laser irradiation in certain parts of the visible and near infrared spectral ranges. Broad clinical applications of laser therapy and slow progress in understanding of the physical, chemical and biological mechanisms of this phenomenon make the task to search new methods of objectivisation of laser-induces bioeffects very insistent. In this paper we give a short review of the methods of structural-optical diagnostics of the soft laser-induced effects in biofluids (blood and its fractions, saliva, juices, mucuses, exudations, etc.) and suggest their applications in experimental and clinical studies of the soft laser bioeffects.

  3. A nondestructive method for diagnostic of insulated building walls using infrared thermography

    NASA Astrophysics Data System (ADS)

    Larbi Youcef, Mohamed H. A.; Mazioud, Atef; Bremond, Pierre; Ibos, Laurent; Candau, Yves; Piro, Michel; Filloux, Alain

    2007-04-01

    This work deals with the development of an experimental protocol for the diagnostic of multi-layered insulated building walls. First, a test bench is set up in order to measure front and back sides temperatures of standard panels. The panels considered have insulation thicknesses of 2, 6 and 10cm. The front side is heated by two halogen lamps of 500W. A CEDIP Jade Long wave infrared camera and thermocouples are used to carry out temperature measurements. In a second time, a one dimensional model based on thermal quadruples and Laplace transforms was developped under Matlab environment. Also, we developped a three dimensional model based on finite volumes using Fluent computational code. Finally, a method of identification of physical parameters is implemented by performing least square minimization based on Levenberg-Marquardt method. The experimental measurements are compared to theoretical results and by minimization we obtain thermal conductivity and diffusivity as well as thickness of the two layers.

  4. Diagnostic radiology peer review: a method inclusive of all interpreters of radiographic examinations regardless of specialty.

    PubMed

    Hopper, K D; Rosetti, G F; Edmiston, R B; Madewell, J E; Beam, L M; Landis, J R; Miller, K L; Ricci, J A; McCauslin, M A

    1991-08-01

    A proposed method of assessing the quality of diagnostic radiographic examinations includes peer review designed to evaluate physicians, including nonradiologists, involved in the performance and interpretation of such examinations. A pilot project evaluated this system with randomly selected Pennsylvania Blue Shield data files of 10 providers billing for chest radiography interpretations during the second quarter of 1989. Of the 98 chest radiographs reviewed blindly, all inadequately marked radiographs and incomplete written reports were produced by nonradiologists. Technical quality of images obtained by radiologists did not significantly differ from that of images obtained by nonradiologists (P = .189). All five interpretive errors that could have seriously affected the patient's health care were produced by nonradiologists (P = .019). Four of these serious errors were made by providers billing for fewer than 25 radiographs. While administrative and time cost limitations are obvious, this method of peer review encompasses all physicians billing for a particular radiographic service, irrespective of specialty. PMID:2068327

  5. Diagnostic accuracy of pre-operative imaging findings in presumed clinical T1a renal cell carcinomas

    PubMed Central

    NAKASHIMA, KAZUFUMI; KITAGAWA, YASUHIDE; IZUMI, KOUJI; MIZOKAMI, ATSUSHI; GABATA, TOSHIFUMI; NAMIKI, MIKIO

    2016-01-01

    Despite the development of recent imaging modalities, certain pathological misdiagnoses remain for surgical specimens of presumed small renal cell carcinomas (RCCs). In the present study, a retrospective analysis of benign pathological lesions diagnosed as small RCC prior to surgery was performed. In total, the cases of 196 sporadic renal tumors that was surgically treated as clinical T1a RCCs were reviewed, and the accuracy of the pathological diagnoses was calculated. The pre-operative findings for benign pathological lesions was investigated, and the lesions were observed in 13 (6.63%) of the 196 tumors. Pre-operative computed tomography images were obtained in all cases, and magnetic resonance images were available in 10 cases. The diagnostic accuracy of imaging modalities was significantly lower in the tumors with a diameter of ≤20 mm. In all cases, the possible pathological diagnosis of RCC could not be excluded even by retrospective imaging analysis. Several benign pathological lesions were found in small renal masses presumed to be clinical T1a RCC. In conclusion, there may be limitations to the pre-operative imaging for certain types of small renal mass. PMID:27123087

  6. A simple method of observation impact analysis for operational storm surge forecasting systems

    NASA Astrophysics Data System (ADS)

    Sumihar, Julius; Verlaan, Martin

    2016-04-01

    In this work, a simple method is developed for analyzing the impact of assimilating observations in improving forecast accuracy of a model. The method simply makes use of observation time series and the corresponding model output that are generated without data assimilation. These two time series are usually available in an operational database. The method is therefore easy to implement. Moreover, it can be used before actually implementing any data assimilation to the forecasting system. In this respect, it can be used as a tool for designing a data assimilation system, namely for searching for an optimal observing network. The method can also be used as a diagnostic tool, for example, for evaluating an existing operational data assimilation system to check if all observations are contributing positively to the forecast accuracy. The method has been validated with some twin experiments using a simple one-dimensional advection model as well as with an operational storm surge forecasting system based on the Dutch Continental Shelf model version 5 (DCSMv5). It has been applied for evaluating the impact of observations in the operational data assimilation system with DCSMv5 and for designing a data assimilation system for the new model DCSMv6. References: Verlaan, M. and J. Sumihar (2016), Observation impact analysis methods for storm surge forecasting systems, Ocean Dynamics, ODYN-D-15-00061R1 (in press) Zijl, F., J. Sumihar, and M. Verlaan (2015), Application of data assimilation for improved operational water level forecasting of the northwest European shelf and North Sea, Ocean Dynamics, 65, Issue 12, pp 1699-1716.

  7. Bacteriological comparison of low anal fistula operated by ordinary methods and laser methods

    NASA Astrophysics Data System (ADS)

    Yang, Yuanrong; Xiong, Yigai

    1996-09-01

    Since 1989, 42 cases with low anal fistula were operated with laser and ordinary methods respectively. During the operation, secreted or charred tissues were extracted from the surface of the wound for bacteria culture. Experimental group (laser method): no bacteria were found in 24 cases operated by laser method. Control group (ordinary method): bacterial were found in 16 out of 18 cases operated by ordinary methods. The results of two different group showed that they had statistical difference for P < 0.001. So, CO2 laser is proved to be a definitely practical tool in surgical use for its bacteria killing power. While the anal fistula were operated by the laser, the neurotic carboatomic tissue can block blood vessel and prevent infection from spreading. The high temperature produced by the carboatomic action have enough ability to kill directly the bacteria living in the anal fistula.

  8. Processing module operating methods, processing modules, and communications systems

    DOEpatents

    McCown, Steven Harvey; Derr, Kurt W.; Moore, Troy

    2014-09-09

    A processing module operating method includes using a processing module physically connected to a wireless communications device, requesting that the wireless communications device retrieve encrypted code from a web site and receiving the encrypted code from the wireless communications device. The wireless communications device is unable to decrypt the encrypted code. The method further includes using the processing module, decrypting the encrypted code, executing the decrypted code, and preventing the wireless communications device from accessing the decrypted code. Another processing module operating method includes using a processing module physically connected to a host device, executing an application within the processing module, allowing the application to exchange user interaction data communicated using a user interface of the host device with the host device, and allowing the application to use the host device as a communications device for exchanging information with a remote device distinct from the host device.

  9. Method of low temperature operation of an electrochemical cell array

    DOEpatents

    Singh, Prabhakar; Ruka, Roswell J.; Bratton, Raymond J.

    1994-01-01

    In the method of operating an electrochemical cell generator apparatus containing a generator chamber (20) containing an array of cells (12) having interior and exterior electrodes with solid electrolyte between the electrodes, where a hot gas (F) contacts the outside of the cells (12) and the generating chamber normally operates at over 850.degree. C., where N.sub.2 gas is fed to contact the interior electrode of the cells (12) in any case when the generating chamber (20) temperature drops for whatever reason to within the range of from 550.degree. C. to 800.degree. C., to eliminate cracking within the cells (12).

  10. Diagnostic methods to cutaneous leishmaniasis detection in domestic dogs and cats*

    PubMed Central

    Trevisan, Daliah Alves Coelho; Lonardoni, Maria Valdrinez Campana; Demarchi, Izabel Galhardo

    2015-01-01

    Cutaneous leishmaniasis is caused by different species of Leishmania. In domestic animals such as dogs and cats, the diagnostic consists of clinical, epidemiological and serological tests, which changes among countries all around the world. Because of this diversity in the methods selected, we propose this systematic literature review to identify the methods of laboratory diagnosis used to detect cutaneous leishmaniasis in domestic dogs and cats in the Americas. Articles published in the last 5 years were searched in PubMed, ISI Web of Science, LILACS and Scielo, and we selected 10 papers about cutaneous leishmaniasis in dogs and cats in the Americas. In Brazil, often the indirect immunofluorescence and enzyme immunoassay (ELISA) have been applied. Other countries like United States and Mexico have been using antigenic fractions for antibodies detections by Western blot. ELISA and Western blot showed a higher sensitivity and efficacy in the detection of leishmaniasis. Analysis of sensibility and specificity of the methods was rarely used. Although confirmatory to leishmaniasis, direct methods for parasites detection and polymerase chain reaction showed low positivity in disease detection. We suggested that more than one method should be used for the detection of feline and canine leishmaniasis. Serological methods such as Western blot and enzyme immunoassay have a high efficacy in the diagnosis of this disease. PMID:26734869