Science.gov

Sample records for passive heat removal

  1. Passive shut-down heat removal system

    DOEpatents

    Hundal, Rolv; Sharbaugh, John E.

    1988-01-01

    An improved shut-down heat removal system for a liquid metal nuclear reactor of the type having a vessel for holding hot and cold pools of liquid sodium is disclosed herein. Generally, the improved system comprises a redan or barrier within the reactor vessel which allows an auxiliary heat exchanger to become immersed in liquid sodium from the hot pool whenever the reactor pump fails to generate a metal-circulating pressure differential between the hot and cold pools of sodium. This redan also defines an alternative circulation path between the hot and cold pools of sodium in order to equilibrate the distribution of the decay heat from the reactor core. The invention may take the form of a redan or barrier that circumscribes the inner wall of the reactor vessel, thereby defining an annular space therebetween. In this embodiment, the bottom of the annular space communicates with the cold pool of sodium, and the auxiliary heat exchanger is placed in this annular space just above the drawn-down level that the liquid sodium assumes during normal operating conditions. Alternatively, the redan of the invention may include a pair of vertically oriented, concentrically disposed standpipes having a piston member disposed between them that operates somewhat like a pressure-sensitive valve. In both embodiments, the cessation of the pressure differential that is normally created by the reactor pump causes the auxiliary heat exchanger to be immersed in liquid sodium from the hot pool. Additionally, the redan in both embodiments forms a circulation flow path between the hot and cold pools so that the decay heat from the nuclear core is uniformly distributed within the vessel.

  2. Horizontal Heat Exchanger Design and Analysis for Passive Heat Removal Systems

    SciTech Connect

    Vierow, Karen

    2005-08-29

    This report describes a three-year project to investigate the major factors of horizontal heat exchanger performance in passive containment heat removal from a light water reactor following a design basis accident LOCA (Loss of Coolant Accident). The heat exchanger studied in this work may be used in advanced and innovative reactors, in which passive heat removal systems are adopted to improve safety and reliability The application of horizontal tube-bundle condensers to passive containment heat removal is new. In order to show the feasibility of horizontal heat exchangers for passive containment cooling, the following aspects were investigated: 1. the condensation heat transfer characteristics when the incoming fluid contains noncondensable gases 2. the effectiveness of condensate draining in the horizontal orientation 3. the conditions that may lead to unstable condenser operation or highly degraded performance 4. multi-tube behavior with the associated secondary-side effects This project consisted of two experimental investigations and analytical model development for incorporation into industry safety codes such as TRAC and RELAP. A physical understanding of the flow and heat transfer phenomena was obtained and reflected in the analysis models. Two gradute students (one funded by the program) and seven undergraduate students obtained research experience as a part of this program.

  3. Heat transfer analysis of the passive residual heat removal system in ROSA/AP600 experiments

    SciTech Connect

    Yonomoto, Taisuke; Kukita, Yutaka; Schultz, R.R.

    1998-10-01

    The passive residual heat removal (PRHR) system in the Westinghouse AP600 advanced passive reactor design is a natural-circulation-driven heat exchanger cooled by the water in the in-containment refueling water storage tank (IRWST). During the experiments, which simulated small-break loss-of-coolant accidents in the AP600 reactor using the ROSA-V Large-Scale Test Facility (LSTF), the PRHR system heat removal rates well exceeded the core decay power soon after the actuation of the PRHR. This resulted in continuous cooldown and depressurization of the primary side. The PRHR heat transfer performance in these experiments was analyzed by applying heat transfer correlations available in literature to the PRHR heat exchanger tube bundle. Also, the three-dimensional natural circulation in the IRWST was simulated numerically using the FLUENT code. The total heat transfer rate of the PRHR was predicted within 5% of the measured value. The fluid temperature distribution in the IRWST was also predicted well except that the elevation of the thermally stratified region was underpredicted. The calculated flow pattern in the IRWST suggests that the atypical IRWST geometry in the LSTF may have affected the PRHR heat transfer performance during the experiments only a little.

  4. Passive decay heat removal system for water-cooled nuclear reactors

    DOEpatents

    Forsberg, Charles W.

    1991-01-01

    A passive decay-heat removal system for a water-cooled nuclear reactor employs a closed heat transfer loop having heat-exchanging coils inside an open-topped, insulated box located inside the reactor vessel, below its normal water level, in communication with a condenser located outside of containment and exposed to the atmosphere. The heat transfer loop is located such that the evaporator is in a position where, when the water level drops in the reactor, it will become exposed to steam. Vapor produced in the evaporator passes upward to the condenser above the normal water level. In operation, condensation in the condenser removes heat from the system, and the condensed liquid is returned to the evaporator. The system is disposed such that during normal reactor operations where the water level is at its usual position, very little heat will be removed from the system, but during emergency, low water level conditions, substantial amounts of decay heat will be removed.

  5. Passive decay heat removal by natural air convection after severe accidents

    SciTech Connect

    Erbacher, F.J.; Neitzel, H.J.; Cheng, X.

    1995-09-01

    The composite containment proposed by the Research Center Karlsruhe and the Technical University Karlsruhe is to cope with severe accidents. It pursues the goal to restrict the consequences of core meltdown accidents to the reactor plant. One essential of this new containment concept is its potential to remove the decay heat by natural air convection and thermal radiation in a passive way. To investigate the coolability of such a passive cooling system and the physical phenomena involved, experimental investigations are carried out at the PASCO test facility. Additionally, numerical calculations are performed by using different codes. A satisfying agreement between experimental data and numerical results is obtained.

  6. Confirmatory analysis of the AP1000 passive residual heat removal heat exchanger with 3-D computational fluid dynamic analysis

    SciTech Connect

    Schwall, James R.; Karim, Naeem U.; Thakkar, Jivan G.; Taylor, Creed; Schulz, Terry; Wright, Richard F.

    2006-07-01

    The AP1000 is an 1100 MWe advanced nuclear power plant that uses passive safety features to enhance plant safety and to provide significant and measurable improvements in plant simplification, reliability, investment protection and plant costs. The AP1000 received final design approval from the US-NRC in 2004. The AP1000 design is based on the AP600 design that received final design approval in 1999. Wherever possible, the AP1000 plant configuration and layout was kept the same as AP600 to take advantage of the maturity of the design and to minimize new design efforts. As a result, the two-loop configuration was maintained for AP1000, and the containment vessel diameter was kept the same. It was determined that this significant power up-rate was well within the capability of the passive safety features, and that the safety margins for AP1000 were greater than those of operating PWRs. A key feature of the passive core cooling system is the passive residual heat removal heat exchanger (PRHR HX) that provides decay heat removal for postulated LOCA and non-LOCA events. The PRHR HX is a C-tube heat exchanger located in the in-containment refueling water storage tank (IRWST) above the core promoting natural circulation heat removal between the reactor cooling system and the tank. Component testing was performed for the AP600 PRHR HX to determine the heat transfer characteristics and to develop correlations to be used for the AP1000 safety analysis codes. The data from these tests were confirmed by subsequent integral tests at three separate facilities including the ROSA facility in Japan. Owing to the importance of this component, an independent analysis has been performed using the ATHOS-based computational fluid dynamics computer code PRHRCFD. Two separate models of the PRHR HX and IRWST have been developed representing the ROSA test geometry and the AP1000 plant geometry. Confirmation of the ROSA test results were used to validate PRHRCFD, and the AP1000 plant model

  7. Study on natural convection capability of liquid gallium for passive decay heat removal system (PDHRS)

    SciTech Connect

    Kang, S.; Ha, K. S.; Lee, S. W.; Park, S. D.; Kim, S. M.; Seo, H.; Kim, J. H.; Bang, I. C.

    2012-07-01

    The safety issues of the SFRs are important due to the fact that it uses sodium as a nuclear coolant, reacting vigorously with water and air. For that reason, there are efforts to seek for alternative candidates of liquid metal coolants having excellent heat transfer property and to adopt improved safety features to the SFR concepts. This study considers gallium as alternative liquid metal coolant applicable to safety features in terms of chemical activity issue of the sodium and aims to experimentally investigate the natural convection capability of gallium as a feasibility study for the development of gallium-based passive safety features in SFRs. In this paper, the design and construction of the liquid gallium natural convection loop were carried out. The experimental results of heat transfer coefficient of liquid gallium resulting in heat removal {approx}2.53 kW were compared with existing correlations and they were much lower than the correlations. To comparison of the experimental data with computer code analysis, gallium property code was developed for employing MARS-LMR (Korea version of RELAP) based on liquid gallium as working fluid. (authors)

  8. A Modular Radiant-Heat-Initiated Passive Decay-Heat-Removal System for Salt-Cooled Reactors

    SciTech Connect

    Forsberg, Charles W

    2007-01-01

    The Advanced High-Temperature Reactor (AHTR), also called the liquid-salt-cooled very high temperature reactor, is a new reactor concept that combines four existing technologies to create a new reactor option: coated-particle graphite-matrix fuels (the same fuel as used in high-temperature gas-cooled reactors), a liquid-fluoride-salt coolant with a boiling point >1200 C, Brayton power cycles, and passive safety systems. A new passive decay-heat cooling system has been invented that is actuated by the increased temperature of the salt under accident conditions and uses radiant heat transfer from and through the salt to a heat exchanger. This safety system takes advantage of two physical properties of the system: (1) the transparency of the salt coolant and (2) the increase in the radiant heat transfer from the salt to a decay-heat exchanger, which is proportional to the temperature of the hot salt to the fourth power (T4) minus the temperature of the heat exchanger surface to the fourth power (T4). For a high-temperature reactor, small increases in coolant temperatures dramatically increase radiant heat transfer.

  9. COMBINED ACTIVE/PASSIVE DECAY HEAT REMOVAL APPROACH FOR THE 24 MWt GAS-COOLED FAST REACTOR

    SciTech Connect

    CHENG,L.Y.; LUDEWIG, H.

    2007-06-01

    Decay heat removal at depressurized shutdown conditions has been regarded as one of the key areas where significant improvement in passive response was targeted for the GEN IV GFR over the GCFR designs of thirty years ago. It has been recognized that the poor heat transfer characteristics of gas coolant at lower pressures needed to be accommodated in the GEN IV design. The design envelope has therefore been extended to include a station blackout sequence simultaneous with a small break/leak. After an exploratory phase of scoping analysis in this project, together with CEA of France, it was decided that natural convection would be selected as the passive decay heat removal approach of preference. Furthermore, a double vessel/containment option, similar to the double vessel/guard vessel approach of the SFR, was selected as the means of design implementation to reduce the PRA risks of the depressurization accident. However additional calculations in conjunction with CEA showed that there was an economic penalty in terms of decay heat removal system heat exchanger size, elevation heights for thermal centers, and most of all in guard containment back pressure for complete reliance on natural convection only. The back pressure ranges complicated the design requirements for the guard containment. Recognizing that the definition of a loss-of-coolant-accident in the GFR is a misnomer, since gas coolant will always be present, and the availability of some driven blower would reduce fuel temperature transients significantly; it was decided instead to aim for a hybrid active/passive combination approach to the selected BDBA. Complete natural convection only would still be relied on for decay heat removal but only after the first twenty four hours after the initiation of the accident. During the first twenty four hour period an actively powered blower would be relied on to provide the emergency decay power removal. However the power requirements of the active blower

  10. Passive Vaporizing Heat Sink

    NASA Technical Reports Server (NTRS)

    Knowles, TImothy R.; Ashford, Victor A.; Carpenter, Michael G.; Bier, Thomas M.

    2011-01-01

    A passive vaporizing heat sink has been developed as a relatively lightweight, compact alternative to related prior heat sinks based, variously, on evaporation of sprayed liquids or on sublimation of solids. This heat sink is designed for short-term dissipation of a large amount of heat and was originally intended for use in regulating the temperature of spacecraft equipment during launch or re-entry. It could also be useful in a terrestrial setting in which there is a requirement for a lightweight, compact means of short-term cooling. This heat sink includes a hermetic package closed with a pressure-relief valve and containing an expendable and rechargeable coolant liquid (e.g., water) and a conductive carbon-fiber wick. The vapor of the liquid escapes when the temperature exceeds the boiling point corresponding to the vapor pressure determined by the setting of the pressure-relief valve. The great advantage of this heat sink over a melting-paraffin or similar phase-change heat sink of equal capacity is that by virtue of the =10x greater latent heat of vaporization, a coolant-liquid volume equal to =1/10 of the paraffin volume can suffice.

  11. Gap between active and passive solar heating

    SciTech Connect

    Balcomb, J.D.

    1985-01-01

    The gap between active and passive solar could hardly be wider. The reasons for this are discussed and advantages to narrowing the gap are analyzed. Ten years of experience in both active and passive systems are reviewed, including costs, frequent problems, performance prediction, performance modeling, monitoring, and cooling concerns. Trends are analyzed, both for solar space heating and for service water heating. A tendency for the active and passive technologies to be converging is observed. Several recommendations for narrowing the gap are presented.

  12. Apparatus for passive removal of subsurface contaminants

    DOEpatents

    Pemberton, B.E.; May, C.P.; Rossabi, J.

    1997-06-24

    An apparatus is provided which passively removes contaminated gases from a subsurface. The apparatus includes a riser pipe extending into a subsurface which has an exterior end in fluid communication with a valve. When well pressure is greater than atmospheric pressure, the valve opens to release contaminants into the atmosphere, and when well pressure is less than atmospheric pressure, the valve closes to prevent flow of air into the well. The valve assembly of the invention comprises a lightweight ball which is lifted from its valve seat with a slight pressure drop between the well and the atmosphere. 7 figs.

  13. Apparatus for passive removal of subsurface contaminants

    DOEpatents

    Pemberton, Bradley E.; May, Christopher P.; Rossabi, Joseph

    1997-01-01

    An apparatus is provided which passively removes contaminated gases from a subsurface. The apparatus includes a riser pipe extending into a subsurface which has an exterior end in fluid communication with a valve. When well pressure is greater than atmospheric pressure, the valve opens to release contaminants into the atmosphere, and when well pressure is less than atmospheric pressure, the valve closes to prevent flow of air into the well. The valve assembly of the invention comprises a lightweight ball which is lifted from its valve seat with a slight pressure drop between the well and the atmosphere.

  14. Passive heat transfer means for nuclear reactors

    DOEpatents

    Burelbach, James P.

    1984-01-01

    An improved passive cooling arrangement is disclosed for maintaining adjacent or related components of a nuclear reactor within specified temperature differences. Specifically, heat pipes are operatively interposed between the components, with the vaporizing section of the heat pipe proximate the hot component operable to cool it and the primary condensing section of the heat pipe proximate the other and cooler component operable to heat it. Each heat pipe further has a secondary condensing section that is located outwardly beyond the reactor confinement and in a secondary heat sink, such as air ambient the containment, that is cooler than the other reactor component. Means such as shrouding normally isolated the secondary condensing section from effective heat transfer with the heat sink, but a sensor responds to overheat conditions of the reactor to open the shrouding, which thereby increases the cooling capacity of the heat pipe. By having many such heat pipes, an emergency passive cooling system is defined that is operative without electrical power.

  15. Passive ice freezing-releasing heat pipe

    DOEpatents

    Gorski, Anthony J.; Schertz, William W.

    1982-01-01

    A heat pipe device has been developed which permits completely passive ice formation and periodic release of ice without requiring the ambient temperature to rise above the melting point of water. This passive design enables the maximum amount of cooling capacity to be stored in the tank.

  16. Carbon Dioxide Removal via Passive Thermal Approaches

    NASA Technical Reports Server (NTRS)

    Lawson, Michael; Hanford, Anthony; Conger, Bruce; Anderson, Molly

    2011-01-01

    A paper describes a regenerable approach to separate carbon dioxide from other cabin gases by means of cooling until the carbon dioxide forms carbon dioxide ice on the walls of the physical device. Currently, NASA space vehicles remove carbon dioxide by reaction with lithium hydroxide (LiOH) or by adsorption to an amine, a zeolite, or other sorbent. Use of lithium hydroxide, though reliable and well-understood, requires significant mass for all but the shortest missions in the form of lithium hydroxide pellets, because the reaction of carbon dioxide with lithium hydroxide is essentially irreversible. This approach is regenerable, uses less power than other historical approaches, and it is almost entirely passive, so it is more economical to operate and potentially maintenance- free for long-duration missions. In carbon dioxide removal mode, this approach passes a bone-dry stream of crew cabin atmospheric gas through a metal channel in thermal contact with a radiator. The radiator is pointed to reject thermal loads only to space. Within the channel, the working stream is cooled to the sublimation temperature of carbon dioxide at the prevailing cabin pressure, leading to formation of carbon dioxide ice on the channel walls. After a prescribed time or accumulation of carbon dioxide ice, for regeneration of the device, the channel is closed off from the crew cabin and the carbon dioxide ice is sublimed and either vented to the environment or accumulated for recovery of oxygen in a fully regenerative life support system.

  17. Passive heating of the ground surface

    NASA Astrophysics Data System (ADS)

    Tyburczyk, Anna

    2016-03-01

    The phenomenon of phase change is one of the most important contemporary issues of thermal engineering. In particular, this applies to all kinds of heat exchanger systems, which should achieve the highest possible efficiency while reducing investment and operating costs. Some of these systems are heat pipes or thermosyphons, which, among others, are used for the heat transfer, temperature stabilization and the regulation of heat flux density. Additionally, they are passive systems, and therefore do not require an external power supply. Heat pipes can be used to stabilize the surface temperature of roads and driveways. Large heat tubes can be applied for heating the surface of bridges and overpasses, which become icy in unfavorable climatic conditions. The paper presents research on the test facility, whose main component is a long vertical copper fin. The temperature at the base of the fin was kept constant for a given series of measurements. Heat receiving fluid was ethanol at atmospheric pressure. The measurement methodology and the results of investigations were discussed. The surface temperature distribution was measured with the infrared camera, and on this basis the local values of heat flow and the heat transfer coefficient were determined. The results were presented as boiling curves for both the fin with the smooth surface and the one covered with a metal capillary-porous structure. The results obtained are useful in the design of heat exchangers, including passive heating of the ground.

  18. The prolactin responses to active and passive heating in man.

    PubMed

    Low, David; Purvis, Alison; Reilly, Thomas; Cable, N Tim

    2005-11-01

    The aim of this study was to compare the prolactin and blood pressure responses at identical core temperatures during active and passive heat stresses, using prolactin as an indirect marker of central fatigue. Twelve male subjects cycled to exhaustion at 60% maximal oxygen uptake (VO2peak) in a room maintained at 33 degrees C (active). In a second trial they were passively heated (passive) in a water bath (41.56 +/- 1.65 degrees C) until core temperature was equal to the core temperature observed at exhaustion during the active trial. Blood samples were taken from an indwelling venous cannula for the determination of serum prolactin during active heating and at corresponding core temperatures during passive heating. Core temperature was not significantly different between the two methods of heating and averaged 38.81 +/- 0.53 and 38.82 +/- 0.70 degrees C (data expressed as means +/- s.d.) at exhaustion during active heating and at the end of passive heating, respectively (P > 0.05). Mean arterial blood pressure was significantly lower throughout passive heating (active, 73 +/- 9 mmHg; passive, 62 +/- 12 mmHg; P < 0.01). Despite the significantly reduced blood pressure responses during passive heating, during both forms of heating the prolactin response was the same (active, 14.9 +/- 12.6 ng ml(-1); passive, 13.3 +/- 9.6 ng ml(-1); n.s.). These results suggest that thermoregulatory, i.e. core temperature, and not cardiovascular afferents provide the key stimulus for the release of prolactin, an indirect marker of central fatigue, during exercise in the heat. PMID:16157657

  19. Decay heat removal in GEN IV gas cooled fast reactors.

    SciTech Connect

    Cheng, L. Y.; Wei, T. Y. C.

    2009-08-01

    The safety goal of the current designs of advanced high-temperature thermal gas-cooled reactors (HTRs) is that no core meltdown would occur in a depressurization event with a combination of concurrent safety system failures. This study focused on the analysis of passive decay heat removal (DHR) in a GEN IV direct-cycle gas-cooled fast reactor (GFR) which is based on the technology developments of the HTRs. Given the different criteria and design characteristics of the GFR, an approach different from that taken for the HTRs for passive DHR would have to be explored. Different design options based on maintaining core flow were evaluated by performing transient analysis of a depressurization accident using the system code RELAP5-3D. The study also reviewed the conceptual design of autonomous systems for shutdown decay heat removal and recommends that future work in this area should be focused on the potential for Brayton cycle DHRs.

  20. Passive ice freezing-releasing heat pipe. [Patent application

    DOEpatents

    Gorski, A.J.; Schertz, W.W.

    1980-09-29

    A heat pipe device has been developed which permits completely passive ice formation and periodic release of ice without requiring the ambient temperature to rise above the melting point of water. This passive design enables the maximum amount of cooling capacity to be stored in the tank.

  1. Barriers and opportunities for passive removal of indoor ozone

    NASA Astrophysics Data System (ADS)

    Gall, Elliott T.; Corsi, Richard L.; Siegel, Jeffrey A.

    2011-06-01

    This paper presents a Monte Carlo simulation to assess passive removal materials (PRMs) that remove ozone with no additional energy input and minimal byproduct formation. Distributions for air exchange rate in a subset of homes in Houston, Texas, were taken from the literature and combined with background ozone removal rates in typical houses and previous experimentally determined ozone deposition velocities to activated carbon cloth and gypsum wallboard PRMs. The median ratio of indoor to outdoor ozone was predicted to be 0.16 for homes with no PRMs installed and ranged from 0.047 to 0.12 for homes with PRMs. Median values of ozone removal effectiveness in these homes ranged from 22% to 68% for the conditions investigated. Achieving an ozone removal effectiveness above 50% in half of the homes would require installing a large area of PRMs and providing enhanced air speed to transport pollutants to PRM surfaces. Challenges associated with achieving this removal include optimizing indoor transport and aesthetic implications of large surface areas of PRM materials.

  2. Position paper -- Waste storage tank heat removal

    SciTech Connect

    Stine, M.D.

    1995-01-03

    The purpose of this paper is to develop and document a position on the heat removal system to be used on the waste storage tanks currently being designed for the Multi-Function Waste Tank Facility (MWTF), project W-236A. The current preliminary design for the waste storage primary tank heat removal system consists of the following subsystems: (1) a once-through dome space ventilation system; (2) a recirculation dome space ventilation system; and (3) an annulus ventilation system. Recently completed and ongoing studies have evaluated alternative heat removal systems in an attempt to reduce system costs and to optimize heat removal capabilities. In addition, a thermal/heat transfer analysis is being performed that will provide assurance that the heat removal systems selected will be capable of removing the total primary tank design heat load of 1.25 MBtu/hr at an allowable operating temperature of 190 F. Although 200 F is the design temperature limit, 190 F has been selected as the maximum allowable operating temperature limit based on instrumentation sensitivity, instrumentation location sensitivity, and other factors. Seven options are discussed and recommendations are made.

  3. Bacterial Biofilm Removal Using Static and Passive Ultrasonic Irrigation

    PubMed Central

    Joy, Joseph; Mathias, Jones; Sagir, V M Mohammed; Babu, Biju P; Chirayath, Kennet J; Hameed, Hisham

    2015-01-01

    Background: The aim of the present study was to evaluate the efficiency of two irrigating techniques - static and dynamic (passive ultrasonic instrumentation) irrigation in the elimination of bacterial biofilm. Materials and Methods: Forty extracted human permanent maxillary central incisors teeth with straight roots and single canals, were randomly allocated to two groups for static irrigation and passive ultrasonic irrigation (PUI). The root canal irrigant used was 2.5 % sodium hypochlorite. The root canals were prepared to tip sizes (20, 40) and tapers (0.04, 0.08). Using system GT instruments (Dentsply Malliefer, Switerzland). The teeth were split longitudinally into two, stained collagen was applied to the canal surfaces and the tooth reassembled for static and PUI. Digital images of the canal surface were taken before and after irrigation with 9, 18, 27 and 37 mL solution. The digital images were analyzed using ImageJ software (National Institute of Health, USA) to quantify residual canal coverage by the stained collagen. The data were analyzed using linear regression models and subjected to statistical analysis. Results: The mean percentage of canal surface with residual collagen increased with the coronal level of canal, decrease in apical size and taper of canal preparation and decrease in the volume of the irrigant. There was less residual collagen after PUI compared with static irrigation. The canal surface facing the open side port of the needle had less residual collagen after irrigation than the opposing surface. Conclusion: The stained collagen biomolecular film could not be removed completely either by passive ultrasonic instrumentation or static irrigation. The PUI was found to be more effective in the removal of collagen, especially in the apical part of the root canal. PMID:26229369

  4. Passive heat-transfer means for nuclear reactors. [LMFBR

    DOEpatents

    Burelbach, J.P.

    1982-06-10

    An improved passive cooling arrangement is disclosed for maintaining adjacent or related components of a nuclear reactor within specified temperature differences. Specifically, heat pipes are operatively interposed between the components, with the vaporizing section of the heat pipe proximate the hot component operable to cool it and the primary condensing section of the heat pipe proximate the other and cooler component operable to heat it. Each heat pipe further has a secondary condensing section that is located outwardly beyond the reactor confinement and in a secondary heat sink, such as air ambient the containment, that is cooler than the other reactor component. By having many such heat pipes, an emergency passive cooling system is defined that is operative without electrical power.

  5. Heat exchanger with a removable tube section

    DOEpatents

    Wolowodiuk, W.; Anelli, J.

    1975-07-29

    A heat exchanger is described in which the tube sheet is secured against primary liquid pressure, but which allows for easy removal of the tube section. The tube section is supported by a flange which is secured by a number of shear blocks, each of which extends into a slot which is immovable with respect to the outer shell of the heat exchanger. (auth)

  6. Human Cardiovascular Responses to Passive Heat Stress

    PubMed Central

    Crandall, Craig G.; Wilson, Thad E.

    2016-01-01

    Heat stress increases human morbidity and mortality compared to normothermic conditions. Many occupations, disease states, as well as stages of life are especially vulnerable to the stress imposed on the cardiovascular system during exposure to hot ambient conditions. This review focuses on the cardiovascular responses to heat stress that are necessary for heat dissipation. To accomplish this regulatory feat requires complex autonomic nervous system control of the heart and various vascular beds. For example, during heat stress cardiac output increases up to twofold, by increases in heart rate and an active maintenance of stroke volume via increases in inotropy in the presence of decreases in cardiac preload. Baroreflexes retain the ability to regulate blood pressure in many, but not all, heat stress conditions. Central hypovolemia is another cardiovascular challenge brought about by heat stress, which if added to a subsequent central volumetric stress, such as hemorrhage, can be problematic and potentially dangerous, as syncope and cardiovascular collapse may ensue. These combined stresses can compromise blood flow and oxygenation to important tissues such as the brain. It is notable that this compromised condition can occur at cardiac outputs that are adequate during normothermic conditions but are inadequate in heat because of the increased systemic vascular conductance associated with cutaneous vasodilation. Understanding the mechanisms within this complex regulatory system will allow for the development of treatment recommendations and countermeasures to reduce risks during the ever-increasing frequency of severe heat events that are predicted to occur. PMID:25589263

  7. Human cardiovascular responses to passive heat stress.

    PubMed

    Crandall, Craig G; Wilson, Thad E

    2015-01-01

    Heat stress increases human morbidity and mortality compared to normothermic conditions. Many occupations, disease states, as well as stages of life are especially vulnerable to the stress imposed on the cardiovascular system during exposure to hot ambient conditions. This review focuses on the cardiovascular responses to heat stress that are necessary for heat dissipation. To accomplish this regulatory feat requires complex autonomic nervous system control of the heart and various vascular beds. For example, during heat stress cardiac output increases up to twofold, by increases in heart rate and an active maintenance of stroke volume via increases in inotropy in the presence of decreases in cardiac preload. Baroreflexes retain the ability to regulate blood pressure in many, but not all, heat stress conditions. Central hypovolemia is another cardiovascular challenge brought about by heat stress, which if added to a subsequent central volumetric stress, such as hemorrhage, can be problematic and potentially dangerous, as syncope and cardiovascular collapse may ensue. These combined stresses can compromise blood flow and oxygenation to important tissues such as the brain. It is notable that this compromised condition can occur at cardiac outputs that are adequate during normothermic conditions but are inadequate in heat because of the increased systemic vascular conductance associated with cutaneous vasodilation. Understanding the mechanisms within this complex regulatory system will allow for the development of treatment recommendations and countermeasures to reduce risks during the ever-increasing frequency of severe heat events that are predicted to occur. PMID:25589263

  8. Passive gas-gap heat switch for adiabatic demagnetization refrigerator

    NASA Technical Reports Server (NTRS)

    Shirron, Peter J. (Inventor); Di Pirro, Michael J. (Inventor)

    2005-01-01

    A passive gas-gap heat switch for use with a multi-stage continuous adiabatic demagnetization refrigerator (ADR). The passive gas-gap heat switch turns on automatically when the temperature of either side of the switch rises above a threshold value and turns off when the temperature on either side of the switch falls below this threshold value. One of the heat switches in this multistage process must be conductive in the 0.25? K to 0.3? K range. All of the heat switches must be capable of switching off in a short period of time (1-2 minutes), and when off to have a very low thermal conductance. This arrangement allows cyclic cooling cycles to be used without the need for separate heat switch controls.

  9. Development of Passive Fuel Cell Thermal Management Heat Exchanger

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian J.; Colozza, Anthony J.

    2010-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates that could conduct the heat, provide a sufficiently uniform temperature heat sink for each cell of the fuel cell stack, and be substantially lighter than the conventional thermal management approach. Tests were run with different materials to evaluate the design approach to a heat exchanger that could interface with the edges of the passive cooling plates. Measurements were made during fuel cell operation to determine the temperature of individual cooling plates and also to determine the temperature uniformity from one cooling plate to another.

  10. Passive rejection of heat from an isotope heat source through an open door

    NASA Technical Reports Server (NTRS)

    Burns, R. K.

    1971-01-01

    The isotope heat-source design for a Brayton power system includes a door in the thermal insulation through which the heat can be passively rejected to space when the power system is not operating. The results of an analysis to predict the heat-source surface temperature and the heat-source heat-exchanger temperature during passive heat rejection as a function of insulation door opening angle are presented. They show that for a door opening angle greater than 20 deg, the temperatures are less than the steady-state temperatures during power system operation.

  11. Passive thermosyphon solar heating and cooling module with supplementary heating

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A collection of three quarterly reports from Sigma Research, Inc., covering progress and status from January through September 1977 are presented. Three heat exchangers are developed for use in a solar heating and cooling system for installation into single-family dwellings. Each exchanger consists of one heating and cooling module and one submerged electric water heating element.

  12. Heat treatment of exchangers to remove coke

    SciTech Connect

    Turner, J.D.

    1990-02-20

    This patent describes a process for preparing furfural coke for removal from metallic surfaces. It comprises: heating the furfural coke without causing an evolution of heat capable of undesirably altering metallurgical properties of the surfaces in the presence of a gas containing molecular oxygen at a sufficient temperature below 800{degrees}F (427{degrees}C) for a sufficient time to change the crush strength of the coke so as to permit removal with a water jet at a pressure of five thousand pounds per square inch.

  13. Entirely passive heat pipe apparatus capable of operating against gravity

    DOEpatents

    Koenig, Daniel R.

    1982-01-01

    The disclosure is directed to an entirely passive heat pipe apparatus capable of operating against gravity for vertical distances in the order of 3 to 7 meters and more. A return conduit into which an inert gas is introduced is used to lower the specific density of the working fluid so that it may be returned a greater vertical distance from condenser to evaporator.

  14. System design package: Maxi-therm S-101 heating module, passive heat exchanger

    NASA Technical Reports Server (NTRS)

    1977-01-01

    This document is the specification which establishes the requirements for the design, installation, and performance of a passive heat exchanger module with auxiliary heaters for use with solar heating systems. It designates the Interim Performance Criteria applicable to the subsystem and defines any deviations. This document also includes the manufacturing instructions and required materials and parts for the Maxitherm S101 Heating Module.

  15. Emergency Decay Heat Removal in a GEN-IV Gas-Cooled Fast Reactor

    SciTech Connect

    Cheng, Lap Y.; Ludewig, Hans; Jo, Jae

    2006-07-01

    A series of transient analyses using the system code RELAP5-3d has been performed to confirm the efficacy of a proposed hybrid active/passive combination approach to the decay heat removal for an advanced 2400 MWt GEN-IV gas-cooled fast reactor. The accident sequence of interest is a station blackout simultaneous with a small break (10 sq.inch/0.645 m{sup 2}) in the reactor vessel. The analyses cover the three phases of decay heat removal in a depressurization accident: (1) forced flow cooling by the power conversion unit (PCU) coast down, (2) active forced flow cooling by a battery powered blower, and (3) passive cooling by natural circulation. The blower is part of an emergency cooling system (ECS) that by design is to sustain passive decay heat removal via natural circulation cooling 24 hours after shutdown. The RELAP5 model includes the helium-cooled reactor, the ECS (primary and secondary side), the PCU with all the rotating machinery (turbine and compressors) and the heat transfer components (recuperator, pre-cooler and inter-cooler), and the guard containment that surrounds the reactor and the PCU. The transient analysis has demonstrated the effectiveness of passive decay heat removal by natural circulation cooling when the guard containment pressure is maintained at or above 800 kPa. (authors)

  16. Incremental cooling load determination for passive direct gain heating systems

    SciTech Connect

    Sullivan, P.W.; Mahone, D.; Fuller, W.; Gruber, J.; Kammerud, R.; Place, W.; Andersson, B.

    1981-05-01

    This paper examines the applicability of the National Association of Home Builders (NAHB) full load compressor hour method for predicting the cooling load increase in a residence, attributable to direct gain passive heating systems. The NAHB method predictions are compared with the results of 200 hour-by-hour simulations using BLAST and the two methods show reasonable agreement. The degree of agreement and the limitations of the NAHB method are discussed.

  17. Analysis of thermal comfort in a passive solar heated residence

    NASA Astrophysics Data System (ADS)

    Liu, S. T.

    1981-11-01

    The thermal comfort conditions in a passive solar heated residence of the popular Trombe Wall configuration were investigated. The indoor thermal environment of an actual passive solar residence, using the typical meteorological year (TMY) weather data tape as input as three locations of different climatic conditions was simulated. The relevant thermal comfort parameters such as the space air temperature, mean radiant temperatures, operative temperatures, radiant temperature asymmetry, and temperature drifts of the occupied zone, were computed for a prime heating month, a transition month and a prime cooling month of a typical weather year at the three locations. It is found that for the specific passive solar residence analyzed, the upper boundary of the comfort envelope can be exceeded (overheating) during a typical clear day in the transition month of April unless a change of clothing to summer wear is made during the daytime high solar radiation house. The upper boundary will be exceeded during a typical clear day in the prime cooling month of August for a person in typical summer clothing at all three locations unless the average air movement in the occupied zone is increased above the level of natural circulation, or the thermostat setting is reduced to a lower level, or both.

  18. The Gas-Cooled Fast Reactor: Report on Safety System Design for Decay Heat Removal

    SciTech Connect

    K. D. Weaver; T. Marshall; T. Y. C. Wei; E. E. Feldman; M. J. Driscoll; H. Ludewig

    2003-09-01

    The gas-cooled fast reactor (GFR) was chosen as one of the Generation IV nuclear reactor systems to be developed based on its excellent potential for sustainability through reduction of the volume and radiotoxicity of both its own fuel and other spent nuclear fuel, and for extending/utilizing uranium resources orders of magnitude beyond what the current open fuel cycle can realize. In addition, energy conversion at high thermal efficiency is possible with the current designs being considered, thus increasing the economic benefit of the GFR. However, research and development challenges include the ability to use passive decay heat removal systems during accident conditions, survivability of fuels and in-core materials under extreme temperatures and radiation, and economical and efficient fuel cycle processes. This report addresses/discusses the decay heat removal options available to the GFR, and the current solutions. While it is possible to design a GFR with complete passive safety (i.e., reliance solely on conductive and radiative heat transfer for decay heat removal), it has been shown that the low power density results in unacceptable fuel cycle costs for the GFR. However, increasing power density results in higher decay heat rates, and the attendant temperature increase in the fuel and core. Use of active movers, or blowers/fans, is possible during accident conditions, which only requires 3% of nominal flow to remove the decay heat. Unfortunately, this requires reliance on active systems. In order to incorporate passive systems, innovative designs have been studied, and a mix of passive and active systems appears to meet the requirements for decay heat removal during accident conditions.

  19. Solar passive ceiling system. Final report. [Passive solar heating system with venetian blind reflectors and latent heat storage in ceiling

    SciTech Connect

    Schneider, A.R.

    1980-01-01

    The construction of a 1200 square foot building, with full basement, built to be used as a branch library in a rural area is described. The primary heating source is a passive solar system consisting of a south facing window system. The system consists of: a set of windows located in the south facing wall only, composed of double glazed units; a set of reflectors mounted in each window which reflects sunlight up to the ceiling (the reflectors are similar to venetian blinds); a storage area in the ceiling which absorbs the heat from the reflected sunlight and stores it in foil salt pouches laid in the ceiling; and an automated curtain which automatically covers and uncovers the south facing window system. The system is totally passive and uses no blowers, pumps or other active types of heat distribution equipment. The building contains a basement which is normally not heated, and the north facing wall is bermed four feet high around the north side.

  20. Sympathetic activity during passive heat stress in healthy aged humans

    PubMed Central

    Gagnon, Daniel; Schlader, Zachary J; Crandall, Craig G

    2015-01-01

    Abstract Cardiovascular adjustments during heat stress are generally attenuated in healthy aged humans, which could be due to lower increases in sympathetic activity compared to the young. We compared muscle sympathetic nerve activity (MSNA) between 11 young (Y: 28 ± 4 years) and 10 aged (A: 70 ± 5 years) subjects prior to and during passive heating. Furthermore, MSNA responses were compared when a cold pressor test (CPT) and lower body negative pressure (LBNP) were superimposed upon heating. Baseline MSNA burst frequency (Y: 15 ± 4 vs. A: 31 ± 3 bursts min−1, P ≤ 0.01) and burst incidence (Y: 26 ± 8 vs. A: 50 ± 7 bursts (100 cardiac cycles (CC))−1, P ≤ 0.01) were greater in the aged. Heat stress increased core temperature to a similar extent in both groups (Y: +1.2 ± 0.1 vs. A: +1.2 ± 0.0°C, P = 0.99). Absolute levels of MSNA remained greater in the aged during heat stress (burst frequency: Y: 47 ± 6 vs. A: 63 ± 11 bursts min−1, P ≤ 0.01; burst incidence: Y: 48 ± 8 vs. A: 67 ± 9 bursts (100 CC)−1, P ≤ 0.01); however, the increase in both variables was similar between groups (both P ≥ 0.1). The CPT and LBNP further increased MSNA burst frequency and burst incidence, although the magnitude of increase was similar between groups (both P ≥ 0.07). These results suggest that increases in sympathetic activity during heat stress are not attenuated in healthy aged humans. Key points Cardiovascular adjustments to heat stress are attenuated in healthy aged individuals, which could contribute to their greater prevalence of heat-related illnesses and deaths during heat waves. The attenuated cardiovascular adjustments in the aged could be due to lower increases in sympathetic nerve activity during heat stress. We examined muscle sympathetic nerve activity (MSNA) and plasma catecholamine concentrations in healthy young and aged individuals during whole-body passive heat stress. The main finding

  1. Condensate removal device for heat exchanger

    NASA Technical Reports Server (NTRS)

    Trusch, R. B.; Oconnor, E. W. (Inventor)

    1975-01-01

    A set of perforated tubes disposed at the gas output side of a heat exchanger, in a position not to affect the rate of flow of the air or other gas is described. The tubes are connected to a common manifold which is connected to a sucking device. Where it is necessary to conserve and recirculate the air sucked through the tubes, the output of the manifold is run through a separator to remove the condensate from the gas. The perforations in the slurper tubes are small, lying in the range of 0.010 inch to 0.100 inch. The tubes are disposed in contact with the surfaces of the heat exchanger on which the condensate is precipitated, whether fins or plates, so that the water may be directed to the tube openings by means of surface effects, together with the assistance of the air flow. Only about 5 percent of the air output need be thus diverted, and it effectively removes virtually all of the condensate.

  2. Optimization of storage in passive solar heating systems. Final report

    SciTech Connect

    Bahm, R.J.

    1980-05-01

    The search for a simple method of estimating the optimum amount of storage for passive solar space heating system designs and the results of that search are described. The project goals, and why the project is important are described. The major project results are presented in the order of their importance with respect to meeting the project goal. A narrative description of the project is given. Here the various approaches attempted are described, giving the reasons for failure in those areas that were not successful. The Appendices contain the bulk of data generated by this project. Most of the data is presented in graphical form. (MHR)

  3. Wallboard with Latent Heat Storage for Passive Solar Applications

    SciTech Connect

    Kedl, R.J.

    2001-05-31

    Conventional wallboard impregnated with octadecane paraffin [melting point-23 C (73.5 F)] is being developed as a building material with latent heat storage for passive solar and other applications. Impregnation was accomplished simply by soaking the wallboard in molten wax. Concentrations of wax in the combined product as high as 35% by weight can be achieved. Scale-up of the soaking process, from small laboratory samples to full-sized 4- by 8-ft sheets, has been successfully accomplished. The required construction properties of wallboard are maintained after impregnation, that is, it can be painted and spackled. Long-term, high-temperature exposure tests and thermal cycling tests showed no tendency of the paraffin to migrate within the wallboard, and there was no deterioration of thermal energy storage capacity. In support of this concept, a computer model was developed to handle thermal transport and storage by a phase change material (PCM) dispersed in a porous media. The computer model was confirmed by comparison with known analytical solutions and also by comparison with temperatures measured in wallboard during an experimentally generated thermal transient. Agreement between the model and known solution was excellent. Agreement between the model and thermal transient was good, only after the model was modified to allow the PCM to melt over a temperature range, rather than at a specific melting point. When the melting characteristics of the PCM (melting point, melting range, and heat of fusion), as determined from a differential scanning calorimeter plot, were used in the model, agreement between the model and transient data was very good. The confirmed computer model may now be used in conjunction with a building heating and cooling code to evaluate design parameters and operational characteristics of latent heat storage wallboard for passive solar applications.

  4. Nuclear reactor with makeup water assist from residual heat removal system

    DOEpatents

    Corletti, M.M.; Schulz, T.L.

    1993-12-07

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path. 2 figures.

  5. Nuclear reactor with makeup water assist from residual heat removal system

    DOEpatents

    Corletti, Michael M.; Schulz, Terry L.

    1993-01-01

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path.

  6. Effects of passive heat stress on human somatosensory processing.

    PubMed

    Nakata, Hiroki; Oshiro, Misaki; Namba, Mari; Shibasaki, Manabu

    2015-12-01

    Herein, we investigated the effects of passive heat stress on human somatosensory processing recorded by somatosensory-evoked potentials (SEPs). Fifteen healthy subjects received a median nerve stimulation at the left wrist under two thermal conditions: Heat Stress and normothermic Time Control. The latencies and amplitudes of P14, N20, P25, N35, P45, and N60 at C4' and P14, N18, P22, and N30 at Fz were evaluated. Under the Heat Stress condition, SEPs were recorded at normothermic baseline (1st), early in heat stress (2nd), when esophageal temperature had increased by ~1.0°C (3rd) and ~2.0°C (4th), and after heat stress (5th). In the Time Control condition, SEPs were measured at the same time intervals as those in the Heat Stress condition. The peak latencies and amplitudes of SEPs did not change early in heat stress. However, the latencies of P14, N20, and N60 at C4' and P14, N18, and P22 at Fz were significantly shorter in the 4th session than in the 1st session. Furthermore, the peak amplitudes of P25 and N60 at C4', and P22 and N30 at Fz decreased with increases in body temperature. On the other hand, under the Time Control condition, no significant differences were observed in the amplitudes or latencies of any component of SEPs. These results suggested that the conduction velocity of the ascending somatosensory input was accelerated by increases in body temperature, and hyperthermia impaired the neural activity of cortical somatosensory processing. PMID:26468258

  7. A passive solar system for downward heat transport

    SciTech Connect

    Stacy, W.D.

    1982-01-01

    This paper discusses the development and testing of a unique passive solar DHW system employing roof mounted conventional flat plate collectors and a conventional coil-in-tank hot water heater located 20 feet below the collectors. The system operates as an intermittent heat pipe in a two stroke cycle involving day time boil down/night time condensate return. System concept, construction details, and test results are presented for the 40 ft/sup 2/, 40 gpd workhorse prototype DHW system. Passive system cycling was experimentally confirmed to be completely reliable under both design and off-design conditions of usage, isolation, and weather. Day long system efficiency averaged 35% to 40% between July and December in northern New England and reached 45% under favorable ambient conditions. System attributes regarding performance, reliability, and site/installation flexibility are described and discussed. Key advantages of boiling/condensing fluid systems in solar applications are noted, and the need for further development of appropriate working fluids is discussed in the context of evolving codes.

  8. Heat recirculating cooler for fluid stream pollutant removal

    DOEpatents

    Richards, George A.; Berry, David A.

    2008-10-28

    A process by which heat is removed from a reactant fluid to reach the operating temperature of a known pollutant removal method and said heat is recirculated to raise the temperature of the product fluid. The process can be utilized whenever an intermediate step reaction requires a lower reaction temperature than the prior and next steps. The benefits of a heat-recirculating cooler include the ability to use known pollutant removal methods and increased thermal efficiency of the system.

  9. Conventional wallboard with latent heat storage for passive solar applications

    SciTech Connect

    Kedl, R.J.

    1990-01-01

    Conventional wallboard impregnated with octadecane paraffin (Melting Point -- 73.5{degree}F) is being developed as a building material with latent heat storage for passive solar applications. Impregnation was accomplished simply by soaking the wallboard in molten paraffin. Concentrations of paraffin in the combined product as high as 35{percent} by weight were achieved. In support of this concept, a computer model was developed to describe thermal transport and storage by a phase change material (PCM) dispersed in a porous media. The computer model was confirmed by comparison with known analytical solutions where the PCM melts at a specific melting point. However, agreement between the model and an experimentally produced thermal transient involving impregnated wallboard was only good after the model was modified to allow the paraffin to melt over a temperature range. This was accomplished by replacing the heat of fusion with a triangular heat capacity relationship that mimics the triangular melt curve found through differential scanning calorimetry. When this change was made, agreement between the model and the experimental transient was very good. 4 refs., 8 figs.

  10. Performance of Decay Heat Removal Systems in the LS-VHTR

    SciTech Connect

    Sienicki, James J.; Moisseytsev, Anton; Farmer, Mitchell T.; Dunn, Floyd E.; Cahalan, James E.

    2006-07-01

    Investigations are underway to determine the viability of the Liquid Salt-Cooled - Very High Temperature Reactor (LS-VHTR) concept which combines fuel and moderator similar to gas cooled VHTR concepts but utilizes liquid salt coolant which can operate at low pressures with improved heat transfer properties relative to helium. Analyses have been carried out investigating the viability of two alternative passive approaches for emergency decay heat removal for a 2400 MWt LS-VHTR: RVACS air natural circulation cooling of the exterior of the guard vessel and DRACS Direct Reactor Heat Exchangers (DRHXs) immersed in the liquid salt coolant and connected to natural draft air heat exchangers through secondary and tertiary cooling circuits. Results of first principles and integrated systems analyses of RVACS and DRACS performance are presented for a postulated accident scenario involving loss-of-normal heat removal, loss-of-forced (pumped) liquid salt flow, and successful scram of the reactor. (authors)

  11. Design and Scaling of the Natural Convection Shutdown Heat Removal Test Facility

    SciTech Connect

    Lisowski, Darius D.; Gerardi, Craig D.; Bremer, Nathan C.; Farmer, Mitchell T.

    2014-01-01

    The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (ANL) reflects a 1/2 scale model of one conceptual design for passive safety in advanced reactors. The project was initiated in 2010 primarily to conduct ex-vessel, passive decay heat removal experiments in support of the Advanced Reactor Concepts (ARC), Small Modular Reactor (SMR), and Next Generation Nuclear Plant (NGNP) programs while also generating data for code validation purposes. The facility successfully demonstrated scoping objectives in late 2013, and is expected to begin testing by early 2014. The following paper summarizes some of the key design and scaling considerations used in construction of the experimental facility, along with an overview of the current instrumentation and data acquisition methods. Details of the distributed fiber optic temperature system will be presented, which introduces a level of data density suitable for CFD validation and is a first-of-its-kind for largescale thermal hydraulics facilities.

  12. Emergency heat removal system for a nuclear reactor

    DOEpatents

    Dunckel, Thomas L.

    1976-01-01

    A heat removal system for nuclear reactors serving as a supplement to an Emergency Core Cooling System (ECCS) during a Loss of Coolant Accident (LOCA) comprises a plurality of heat pipes having one end in heat transfer relationship with either the reactor pressure vessel, the core support grid structure or other in-core components and the opposite end located in heat transfer relationship with a heat exchanger having heat transfer fluid therein. The heat exchanger is located external to the pressure vessel whereby excessive core heat is transferred from the above reactor components and dissipated within the heat exchanger fluid.

  13. Age alters the cardiovascular response to direct passive heating

    NASA Technical Reports Server (NTRS)

    Minson, C. T.; Wladkowski, S. L.; Cardell, A. F.; Pawelczyk, J. A.; Kenney, W. L.

    1998-01-01

    During direct passive heating in young men, a dramatic increase in skin blood flow is achieved by a rise in cardiac output (Qc) and redistribution of flow from the splanchnic and renal vascular beds. To examine the effect of age on these responses, seven young (Y; 23 +/- 1 yr) and seven older (O; 70 +/- 3 yr) men were passively heated with water-perfused suits to their individual limit of thermal tolerance. Measurements included heart rate (HR), Qc (by acetylene rebreathing), central venous pressure (via peripherally inserted central catheter), blood pressures (by brachial auscultation), skin blood flow (from increases in forearm blood flow by venous occlusion plethysmography), splanchnic blood flow (by indocyanine green clearance), renal blood flow (by p-aminohippurate clearance), and esophageal and mean skin temperatures. Qc was significantly lower in the older than in the young men (11.1 +/- 0.7 and 7.4 +/- 0.2 l/min in Y and O, respectively, at the limit of thermal tolerance; P < 0. 05), despite similar increases in esophageal and mean skin temperatures and time to reach the limit of thermal tolerance. A lower stroke volume (99 +/- 7 and 68 +/- 4 ml/beat in Y and O, respectively, P < 0.05), most likely due to an attenuated increase in inotropic function during heating, was the primary factor for the lower Qc observed in the older men. Increases in HR were similar in the young and older men; however, when expressed as a percentage of maximal HR, the older men relied on a greater proportion of their chronotropic reserve to obtain the same HR response (62 +/- 3 and 75 +/- 4% maximal HR in Y and O, respectively, P < 0.05). Furthermore, the older men redistributed less blood flow from the combined splanchnic and renal circulations at the limit of thermal tolerance (960 +/- 80 and 720 +/- 100 ml/min in Y and O, respectively, P < 0. 05). As a result of these combined attenuated responses, the older men had a significantly lower increase in total blood flow directed to

  14. Age alters the cardiovascular response to direct passive heating.

    PubMed

    Minson, C T; Wladkowski, S L; Cardell, A F; Pawelczyk, J A; Kenney, W L

    1998-04-01

    During direct passive heating in young men, a dramatic increase in skin blood flow is achieved by a rise in cardiac output (Qc) and redistribution of flow from the splanchnic and renal vascular beds. To examine the effect of age on these responses, seven young (Y; 23 +/- 1 yr) and seven older (O; 70 +/- 3 yr) men were passively heated with water-perfused suits to their individual limit of thermal tolerance. Measurements included heart rate (HR), Qc (by acetylene rebreathing), central venous pressure (via peripherally inserted central catheter), blood pressures (by brachial auscultation), skin blood flow (from increases in forearm blood flow by venous occlusion plethysmography), splanchnic blood flow (by indocyanine green clearance), renal blood flow (by p-aminohippurate clearance), and esophageal and mean skin temperatures. Qc was significantly lower in the older than in the young men (11.1 +/- 0.7 and 7.4 +/- 0.2 l/min in Y and O, respectively, at the limit of thermal tolerance; P < 0. 05), despite similar increases in esophageal and mean skin temperatures and time to reach the limit of thermal tolerance. A lower stroke volume (99 +/- 7 and 68 +/- 4 ml/beat in Y and O, respectively, P < 0.05), most likely due to an attenuated increase in inotropic function during heating, was the primary factor for the lower Qc observed in the older men. Increases in HR were similar in the young and older men; however, when expressed as a percentage of maximal HR, the older men relied on a greater proportion of their chronotropic reserve to obtain the same HR response (62 +/- 3 and 75 +/- 4% maximal HR in Y and O, respectively, P < 0.05). Furthermore, the older men redistributed less blood flow from the combined splanchnic and renal circulations at the limit of thermal tolerance (960 +/- 80 and 720 +/- 100 ml/min in Y and O, respectively, P < 0. 05). As a result of these combined attenuated responses, the older men had a significantly lower increase in total blood flow directed to

  15. Coronary Sinus Lead Removal: A Comparison between Active and Passive Fixation Leads

    PubMed Central

    Yildirim, Yalin; Gosau, Nils; Aydin, Ali; Willems, Stephan; Treede, Hendrik; Reichenspurner, Hermann; Hakmi, Samer

    2016-01-01

    Background Implantation of coronary sinus (CS) leads may be a difficult procedure due to different vein anatomies and a possible lead dislodgement. The mode of CS lead fixation has changed and developed in recent years. Objectives We compared the removal procedures of active and passive fixation leads. Methods Between January 2009 and January 2014, 22 patients at our centre underwent CS lead removal, 6 active and 16 passive fixation leads were attempted using simple traction or lead locking devices with or without laser extraction sheaths. Data on procedural variables and success rates were collected and retrospectively analyzed. Results The mean patient age was 67.2 ± 9.8 years, and 90.9% were male. The indication for lead removal was infection in all cases. All active fixation leads were Medtronic® Attain StarFix™ Model 4195 (Medtronic Inc., Minneapolis, MN, USA). The mean time from implantation for the active and passive fixation leads was 9.9 ± 11.7 months (range 1.0–30.1) and 48.7 ± 33.6 months (range 5.7–106.4), respectively (p = 0.012). Only 3 of 6 StarFix leads were successfully removed (50%) compared to 16 of 16 (100%) of the passive fixation CS leads (p = 0.013). No death or complications occurred during the 30-day follow-up. Conclusion According to our experience, removal of the Starfix active fixation CS leads had a higher procedural failure rate compared to passive. PMID:27119368

  16. Heat exchanger device and method for heat removal or transfer

    DOEpatents

    Koplow, Jeffrey P.

    2012-07-24

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  17. Heat exchanger device and method for heat removal or transfer

    DOEpatents

    Koplow, Jeffrey P

    2015-03-24

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  18. Heat exchanger device and method for heat removal or transfer

    DOEpatents

    Koplow, Jeffrey P

    2013-12-10

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  19. Heat exchanger device and method for heat removal or transfer

    SciTech Connect

    Koplow, Jeffrey P.

    2015-12-08

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  20. Wallboard with latent heat storage for passive solar applications

    SciTech Connect

    Kedl, R.J.

    1991-05-01

    Conventional wallboard impregnated with octadecane paraffin is being developed as a building material with latent heat storage for passive solar and other applications. Impregnation was accomplished simply by soaking the wallboard in molten wax. Concentrations of wax in the combined product as high as 35% by weight can be achieved. Scale-up of the soaking process, from small laboratory samples to full-sized 4- by 8-ft sheets, has been successfully accomplished. The required construction properties of wallboard are maintained after impregnation, that is, it can be painted and spackled. Long-term, high-temperature exposure tests and thermal cycling tests showed no tendency of the paraffin to migrate within the wallboard, and there was no deterioration of thermal energy storage capacity. In support of this concept, a computer model was developed to handle thermal transport and storage by a phase change material (PCM) dispersed in a porous media. The computer model was confirmed by comparison with known analytical solutions and also by comparison with temperatures measured in wallboard during an experimentally generated thermal transient. Agreement between the model and known solution was excellent. Agreement between the model and thermal transient was good, only after the model was modified to allow the PCM to melt over a temperature range, rather than at a specific melting point. When the melting characteristics of the PCM, as determined from a differential scanning calorimeter plot, were used in the model, agreement between the model and transient data was very good. 11 refs., 25 figs., 2 tabs.

  1. Passive removal of silicone oil through 23 gauge transconjunctival sutureless vitrectomy system

    PubMed Central

    Siyal, Nisar Ahmed; Hargun, Lakhani Das; Wahab, Shahid

    2016-01-01

    Objective: To study the outcomes of passive removal of silicone oil by 23 Gauge Transconjunctival Sutureless Vitrectomy System. Methods: This prospective, consecutive case series study was conducted at Ophthalmology Department Unit I, Dow University of Health Sciences, Civil Hospital Karachi from January 2011 to December 2014. Only psuedophakic eyes with silicone oil temponade were selected. Main outcome measures were intra ocular pressure, time taken for removal of silicone oil, per operative and post operative complications. Pre and post operative IOP was compared by using two-tailed paired t-test and mean values with standard deviation were computed using difference of 95% confidence interval. Chi square test was applied for correlation of different variables. P-value of less than 0.05 was considered statistically significant. Results: Out of 79 patients who underwent passive ROSO, 38 (48.1%) were males. Mean age of patients was 47.5±7.1 (sd) years. Mean time taken for passive ROSO was 7.31±2.41 (sd) minutes. Pre and post operative intra ocular pressure shows statistically significant (p=0.000) decrease in IOP. Retinal redetachment found in 13 (16.5%) cases during follow up period. Conclusion: Passive removal of silicone oil with 23 G suture less vitrectomy system is safe and effective in terms of less per operative and post operative complications. In this simple technique, there is less tissue trauma and little time consumed so it provides more comfort to patients and surgeons as well. PMID:27375708

  2. Heat removal key to shrinking avionics

    NASA Astrophysics Data System (ADS)

    Peterson, George P.

    1987-10-01

    An evaluation is made of the consequences for avionics miniaturization and performance improvement of recent advancements in heat pipe technology. In a heat pipe, the phase change of a working fluid can yield levels of thermal conductivity that are several orders of magnitude greater than solid conductors. Current interest extends to large heat pipes (0.3 m or greater in length), medium-sized heat pipes on which electronic components are mounted, and microheat pipes, whose dimensions are of the order of 5 cm length and 1 mm diameter.

  3. Decay Heat Removal by Natural Circulation of Vacuum Vessel Coolant for ITER

    NASA Astrophysics Data System (ADS)

    Iseli, M.; Bartels, H.-W.; Poucet, A.

    1997-06-01

    The decay heat-driven temperature transients of the in-vessel components following a postulated loss of all in-vessel cooling have been calculated. The resulting time-dependent heat load to the vacuum vessel is due to radiation from the backplate and convection of postulated steam between backplate and vacuum vessel. It is shown, that even for a failure of all in-vessel cooling and total loss of power, the ITER design can rely on passive decay heat removal by natural circulation in one of the two existing cooling loops of the vacuum vessel. A mathematical model describes the transient operating conditions and shows that the temperature established by natural circulation does not exceed 200°C at the maximum shut down heat load to the vacuum vessel. Therefore, no additional emergency cooling system is required if the existing heat exchanger is designed for natural circulation and a bypass is used during normal operation to maintain operation temperature.

  4. Studies of the Deteriorated Turbulent Heat Transfer Regime for the Gas-Cooled Fast Reactor Decay Heat Removal System

    SciTech Connect

    Jeong Ik Lee; Hejzlar, Pavel; Kazimi, Mujid S.; Saha, Pradip

    2006-07-01

    Increased reliance on passive emergency cooling using natural circulation of gas at elevated pressure is one of the major goals for the Gas-cooled Fast Reactor (GFR). Since GFR cores have high power density and low thermal inertia, the decay heat removal (DHR) in depressurization accidents is a key challenge. Furthermore, due to its high surface heat flux and low velocities under natural circulation in any post-LOCA scenario, three effects impair the capability of turbulent gas flow to remove heat from the GFR core, namely: (1) Acceleration effect (2) Buoyancy effect (3) Properties variation. This paper reviews previous work on heat transfer mechanisms and flow characteristics of the Deteriorated Turbulent Heat Transfer (DTHT) regime. It is shown that the GFR's DHR system has a potential for operating in the DTHT regime by performing a simple analysis. A description of the MIT/INL experimental facility designed and built to investigate the DTHT regime is provided together with the first test results. The first runs were performed in the forced convection regime to verify facility operation against well-established forced convection correlations. The results of the three runs at Reynolds numbers 6700, 8000 and 12800 showed good agreement with the Gnielinsky correlation [4], which is considered the best available heat transfer correlation in the forced convection regime and is valid for a large range of Reynolds and Prandtl numbers. However, even in the forced convection regime, the effect of heat transfer properties variation of the fluid was found to be still significant. (authors)

  5. Decision Document for Heat Removal from High Level Waste Tanks

    SciTech Connect

    WILLIS, W.L.

    2000-07-31

    This document establishes the combination of design and operational configurations that will be used to provide heat removal from high-level waste tanks during Phase 1 waste feed delivery to prevent the waste temperature from exceeding tank safety requirement limits. The chosen method--to use the primary and annulus ventilation systems to remove heat from the high-level waste tanks--is documented herein.

  6. Passive-solar-heating project for a single-family residence. Final report

    SciTech Connect

    Starkey, V.J.

    1982-05-01

    This project was a passive home heating system utilizing solar collectors that are part of the roof structure of a 15' x 30' greenhouse. The design utilized solar air collectors constructed on site that are actually part of the roof of the greenhouse. The flow of air is from the storage to the collectors then back to the storage. The storage bin consists of a 5' x 19' concrete insulated bin built into the floor of the greenhouse. The storage mass was gallon plastic jugs. The plastic jugs did not work properly, so they are being replaced by salt rods. This replacement will be an after the fact project by the owner. The concrete storage bin was insulated with 2'' plastic foam insulation, applied to the 8'' concrete wall. The ducts entering and leaving the storage bin have low voltage (12 volt) electric dampers. A cross flow system was used. The heated air circulates from the collectors to storage via ducts in the walls of the lean-to design. The removal of heat from the storage bin was from end to end via the ducts to the central air system for the house. In addition, the greenhouse is connected to the house with a doorway that can be opened to circulate air into the house, a shuttled exhaust fan 1/3H.P. motor has aided in the circulation of air from the storage bin to the collectors and back.

  7. Reaction heat used in static water removal from fuel cells

    NASA Technical Reports Server (NTRS)

    Platner, J. L.

    1966-01-01

    Reaction heat is used for removal of water formed at the hydrogen fuel electrode in a hydrogen-oxygen fuel cell. A portion of the heat inherent in the fuel cell current generation reaction is used to transfer excess water into water vapor and cause it to be exhausted from the cell by a porous vapor transport membrane adjoining a vapor cavity.

  8. Shutdown heat removal: safety water tests. [LMFBR

    SciTech Connect

    1981-07-08

    This specification establishes the requirements to design the SAFETY WATER TESTS to be constructed in the Hydraulic Test Facility (HTF) at the GE San Jose site. The test is an 1/8th scale model of a large loop type breeder reactor or a 1/14th scale model of a large pool type breeder reactor and uses water as the test fluid. It simulates a breeder reactor system with a 0.5 MW heated core with an upper and a lower plenum, a primary loop with 300 gpm flow rate and four auxiliary cooling systems (DRACS) that are to be immersed in the upper plenum and connected to the inlet plenum through a check valve.

  9. Experimental and theoretical study of horizontal tube bundle for passive condensation heat transfer

    NASA Astrophysics Data System (ADS)

    Song, Yong Jae

    The research in this thesis supports the design of a horizontal tube bundle condenser for passive heat removal system in nuclear reactors. From nuclear power plant containment, condensation of steam from a steam/noncondensable gas occurs on the primary side and boiling occurs on the secondary side; thus, heat exchanger modeling is a challenge. For the purpose of this experimental study, a six-tube bundle is used, where the outer diameter, inner diameter, and length of each stainless steel tube measures 38.10mm (1.5 inches), 31.75mm (1.25 inches) and 3.96m (156 inches), respectively. The pitch to diameter ratio was determined based on information gathered from literature surveys, and the dimensions were determined from calculations and experimental data. The objective of the calculations, correlations, and experimental data was to obtain complete condensation within the tube bundle. Experimental conditions for the tests in this thesis work were determined from Design Basis Accident (DBA). The applications are for an actual Passive Containment Cooling Systems (PCCS) condenser under postulated accident conditions in future light water reactors. In this research, steady state and transient experiments were performed to investigate the effect of noncondensable gas on steam condensation inside and boiling outside a tube bundle heat exchanger. The condenser tube inlet steam mass flow rate varied from 18.0 to 48.0 g/s, the inlet pressure varied from 100 kPa to 400 kPa, and the inlet noncondensable gas mass fraction varied from 1% to 10%. The effect of the noncondensable gas was examined by comparing the tube centerline temperatures for various inlet and system conditions. As a result, it was determined that the noncondensable gas accumulated near the condensate film causing a decrease of mass and energy transfer. In addition, the effect of the inlet steam flow rate gas was investigated by comparing the tube centerline temperatures, the conclusion being that, as the inlet

  10. Passive soil heating using an inexpensive infrared mirror design - a proof of concept

    NASA Astrophysics Data System (ADS)

    Rasmussen, C.; Gallery, R. E.; Fehmi, J. S.

    2015-09-01

    There is a need to understand the soil system response to warming in order to model the soil process response to predicted climate change. Current methods for soil warming include expensive and difficult to implement active and passive techniques. Here we test a simple, inexpensive in situ passive soil heating approach, based on easy to construct infrared mirrors that do not require automation or enclosures. The infrared mirrors consisted of 61 × 61 cm glass panels coated with infrared reflecting film. The mirrors as constructed are effective for soil heating in environments typified by an open vegetation canopy. Mirror tests were performed on three soils of varying texture, organic matter content, and heat capacity in a warm semi-arid environment. Results indicated that the infrared mirrors yielded significant heating and drying of soil surface and shallow subsurface relative to unwarmed control treatments, and that warming and drying effects were soil specific with greater potential warming on soils with lower volumetric heat capacity. Partial shading from the mirror frame did produce periods of relative cooling at specific times of the day but overall the mirrors yielded a net soil warming. The results demonstrate proof of concept that the infrared mirrors may be used to passively heat the near soil surface, providing an inexpensive, low-maintenance alternative to other passive and active soil heating technologies.

  11. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas

    PubMed Central

    Lin, Zhong; Ke, Zhi Sheng; Zheng, Qian; Zhao, Zhen Quan; Song, Zong Ming

    2016-01-01

    Purpose. To report a new approach for removal of silicone oil. Methods. All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas. At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula. Then, the blood transfusion tube is removed from the inferior-temporal cannula, and the fluid-air exchange is performed. A passive fluid-air exchange was performed to aspirate the residual silicone oil after gradually turning the patient's head temporally by approximately 90° gradually. Results. After the surgery, all patients had a clear anterior chamber and vitreous cavity on slit lamp and B scan examination, respectively. The mean time taken for silicone oil removal and total surgery was 8.0 ± 1.4 minutes and 12.4 ± 2.5 minutes, respectively. The mean intraocular pressure 1 day, 3 days, 1 week, 1 month, and 3 months after surgery was 9.0 ± 5.8 mmHg, 11.3 ± 7.6 mmHg, 16.1 ± 6.9 mmHg, 17.7 ± 4.8 mmHg, and 17.1 ± 3.5 mmHg, respectively. Conclusion. This new approach may provide a safe and fast method to remove the silicone oil. PMID:27418976

  12. Heat exchanger and water tank arrangement for passive cooling system

    DOEpatents

    Gillett, James E.; Johnson, F. Thomas; Orr, Richard S.; Schulz, Terry L.

    1993-01-01

    A water storage tank in the coolant water loop of a nuclear reactor contains a tubular heat exchanger. The heat exchanger has tubesheets mounted to the tank connections so that the tubesheets and tubes may be readily inspected and repaired. Preferably, the tubes extend from the tubesheets on a square pitch and then on a rectangular pitch therebetween. Also, the heat exchanger is supported by a frame so that the tank wall is not required to support all of its weight.

  13. Passive solar space heating and cooling. (Latest citations from the NTIS Bibliographic database). NewSearch

    SciTech Connect

    Not Available

    1994-10-01

    The bibliography contains citations concerning the passive use of solar energy for space heating and cooling in buildings, houses, and homes. Citations discuss the design, performance, models, and economic analysis of heating and cooling systems. Topics include solar architecture, energy consumption analysis, energy conservation, and heat recovery. Also included are thermal comfort, quality of life, and housing for the elderly. (Contains a minimum of 209 citations and includes a subject term index and title list.)

  14. No effects of acclimation to heat on immune and hormonal responses to passive heating in healthy volunteers

    NASA Astrophysics Data System (ADS)

    Kanikowska, Dominika; Sato, Maki; Sugenoya, Junichi; Iwase, Satoshi; Shimizu, Yuuki; Nishimura, Naoki; Inukai, Yoko

    2012-01-01

    Heat acclimation results in whole body-adaptations that increase heat tolerance, and might also result in changed immune responses. We hypothesized that, after heat acclimation, tumor necrosis factor alpha, interleukin 6 and the lymphocyte count would be altered. Heat acclimation was induced in 6 healthy men by 100 min of heat exposure for 9 days. Heat exposure consisted of (1) 10 min of immersion up to chest-level in water at 42°C and (2) 90 min of passive heating by a warm blanket to maintain tympanic temperature at 37.5°C. The climatic chamber was maintained at 40°C and a relative humidity of 50%. Blood samples were analyzed before and after heat acclimation for natural killer (NK) cell activity, counts of lymphocytes B and T, before and after heat acclimation for peripheral blood morphology, interleukin 6, tumor necrosis factor alpha, and cortisol. A Japanese version of the profile of mood states questionnaire was also administered before and after acclimation. The concentrations of white blood cells, lymphocytes B and T, cortisol, interleukin 6, tumor necrosis factor alpha and NK cell activity showed no significant differences between pre- and post-acclimation, but there was a significantly lower platelet count after acclimation and, with the profile of mood states questionnaire, there was a significant rise in anger after acclimation. It is concluded that heat acclimation by passive heating does not induce alterations in immune or endocrine responses.

  15. Long-term performance of passive materials for removal of ozone from indoor air.

    PubMed

    Cros, C J; Morrison, G C; Siegel, J A; Corsi, R L

    2012-02-01

    The health effects associated with exposure to ozone range from respiratory irritation to increased mortality. In this paper, we explore the use of three green building materials and an activated carbon (AC) mat that remove ozone from indoor air. We studied the effects of long-term exposure of these materials to real environments on ozone removal capability and pre- and post-ozonation emissions. A field study was completed over a 6-month period, and laboratory testing was intermittently conducted on material samples retrieved from the field. The results show sustained ozone removal for all materials except recycled carpet, with greatest ozone deposition velocity for AC mat (2.5-3.8 m/h) and perlite-based ceiling tile (2.2-3.2 m/h). Carbonyl emission rates were low for AC across all field sites. Painted gypsum wallboard and perlite-based ceiling tile had similar overall emission rates over the 6-month period, while carpet had large initial emission rates of undesirable by-products that decayed rapidly but remained high compared with other materials. This study confirms that AC mats and perlite-based ceiling tile are viable surfaces for inclusion in buildings to remove ozone without generating undesirable by-products. PRACTICAL IMPLICATIONS The use of passive removal materials for ozone control could decrease the need for, or even render unnecessary, active but energy consuming control solutions. In buildings where ozone should be controlled (high outdoor ozone concentrations, sensitive populations), materials specifically designed or selected for removing ozone could be implemented, as long as ozone removal is not associated with large emissions of harmful by-products. We find that activated carbon mats and perlite-based ceiling tiles can provide substantial, long-lasting, ozone control. PMID:21777291

  16. Alternative cooling resource for removing the residual heat of reactor

    SciTech Connect

    Park, H. C.; Lee, J. H.; Lee, D. S.; Jung, C. Y.; Choi, K. Y.

    2012-07-01

    The Recirculated Cooling Water (RCW) system of a Candu reactor is a closed cooling system which delivers demineralized water to coolers and components in the Service Building, the Reactor Building, and the Turbine Building and the recirculated cooling water is designed to be cooled by the Raw Service Water (RSW). During the period of scheduled outage, the RCW system provides cooling water to the heat exchangers of the Shutdown Cooling System (SDCS) in order to remove the residual heat of the reactor, so the RCW heat exchangers have to operate at all times. This makes it very hard to replace the inlet and outlet valves of the RCW heat exchangers because the replacement work requires the isolation of the RCW. A task force was formed to prepare a plan to substitute the recirculated water with the chilled water system in order to cool the SDCS heat exchangers. A verification test conducted in 2007 proved that alternative cooling was possible for the removal of the residual heat of the reactor and in 2008 the replacement of inlet and outlet valves of the RCW heat exchangers for both Wolsong unit 3 and 4 were successfully completed. (authors)

  17. Heat exchanger and water tank arrangement for passive cooling system

    DOEpatents

    Gillett, J.E.; Johnson, F.T.; Orr, R.S.; Schulz, T.L.

    1993-11-30

    A water storage tank in the coolant water loop of a nuclear reactor contains a tubular heat exchanger. The heat exchanger has tube sheets mounted to the tank connections so that the tube sheets and tubes may be readily inspected and repaired. Preferably, the tubes extend from the tube sheets on a square pitch and then on a rectangular pitch there between. Also, the heat exchanger is supported by a frame so that the tank wall is not required to support all of its weight. 6 figures.

  18. Decay Heat Removal in GEN IV Gas-Cooled Fast Reactors

    DOE PAGESBeta

    Cheng, Lap-Yan; Wei, Thomas Y. C.

    2009-01-01

    The safety goal of the current designs of advanced high-temperature thermal gas-cooled reactors (HTRs) is that no core meltdown would occur in a depressurization event with a combination of concurrent safety system failures. This study focused on the analysis of passive decay heat removal (DHR) in a GEN IV direct-cycle gas-cooled fast reactor (GFR) which is based on the technology developments of the HTRs. Given the different criteria and design characteristics of the GFR, an approach different from that taken for the HTRs for passive DHR would have to be explored. Different design options based on maintaining core flow weremore » evaluated by performing transient analysis of a depressurization accident using the system code RELAP5-3D. The study also reviewed the conceptual design of autonomous systems for shutdown decay heat removal and recommends that future work in this area should be focused on the potential for Brayton cycle DHRs.« less

  19. A Passive, Adaptive and Autonomous Gas Gap heat Switch

    NASA Astrophysics Data System (ADS)

    Vanapalli, Srinivas; Colijn, Bram; Vermeer, Cris; Holland, Harry; Tirolien, Thierry; ter Brake, H. J. M.

    We report on the development of a heat switch for autonomous temperature control of electronic components in a satellite. A heat switch can modulate when needed between roles of a good thermal conductor and a good thermal insulator. Electronic boxes on a satellite should be maintained within a typical optimum temperature range of 260 to 310 K. The heat sinking is usually by means of a radiator. When the operating temperature of the electronic box increases beyond 310 K, a good contact to the radiator is desired for maximum cooling. On the other hand, when the satellite is in a cold dormant state, the electronics box should be heated by the onboard batteries. In this state a weak thermal contact is desired between the electronic box and the heat sink. In the present study, we are developing a gas gap heat switch in which the sorber material is thermally anchored to the electronic box. A temperature change of the electronic box triggers the (de-)sorption of gas from the sorber material and subsequently the gas pressure in the gas gap. This paper describes the physical principles and the current status of this technology. This approach can be extended to cryogenic temperature range.

  20. Ocular blood flow decreases during passive heat stress in resting humans

    PubMed Central

    2013-01-01

    Background Heat stress induces various physiological changes and so could influence ocular circulation. This study examined the effect of heat stress on ocular blood flow. Findings Ocular blood flow, end-tidal carbon dioxide (PETCO2) and blood pressure were measured for 12 healthy subjects wearing water-perfused tube-lined suits under two conditions of water circulation: (1) at 35°C (normothermia) for 30 min and (2) at 50°C for 90 min (passive heat stress). The blood-flow velocities in the superior temporal retinal arteriole (STRA), superior nasal retinal arteriole (SNRA), and the retinal and choroidal vessels (RCV) were measured using laser-speckle flowgraphy. Blood flow in the STRA and SNRA was calculated from the integral of a cross-sectional map of blood velocity. PETCO2 was clamped at the normothermia level by adding 5% CO2 to the inspired gas. Passive heat stress had no effect on the subjects’ blood pressures. The blood-flow velocity in the RCV was significantly lower after 30, 60 and 90 min of passive heat stress than the normothermic level, with a peak decrease of 18 ± 3% (mean ± SE) at 90 min. Blood flow in the STRA and SNRA decreased significantly after 90 min of passive heat stress conditions, with peak decreases of 14 ± 3% and 14 ± 4%, respectively. Conclusion The findings of this study suggest that passive heat stress decreases ocular blood flow irrespective of the blood pressure or arterial partial pressure of CO2. PMID:24314154

  1. Thermal and cost goal analysis for passive solar heating designs

    SciTech Connect

    Noll, S.A.; Kirschner, C.

    1980-01-01

    Economic methodologies developed over the past several years for the design of residential solar systems have been based on life cycle cost (LCC) minimization. Because of uncertainties involving future economic conditions and the varied decision making processes of home designers, builders, and owners, LCC design approaches are not always appropriate. To deal with some of the constraints that enter the design process, and to narrow the number of variables to those that do not depend on future economic conditions, a simplified thermal and cost goal approach for passive designs is presented. Arithmetic and graphical approaches are presented with examples given for each. Goals discussed include simple payback, solar savings fraction, collection area, maximum allowable construction budget, variable cost goals, and Btu savings.

  2. Heat Deposition and Heat Removal in the UCLA Continuous Current Tokamak

    NASA Astrophysics Data System (ADS)

    Brown, Michael Lee

    1990-01-01

    Energy transfer processes in a steady-state tokamak are examined both theoretically and experimentally in order to determine the patterns of plasma heat deposition to material surfaces and the methods of heat removal. Heat transfer experiments involving actively cooled limiters and heat flux probes were performed in the UCLA Continuous Current Tokamak (CCT). The simple exponential model of plasma power deposition was extended to describe the global heat deposition to the first wall of a steady-state tokamak. The heat flux distribution in CCT was determined from measurements of heat flow to 32 large-area water-cooled Faraday shield panels. Significant toroidal and poloidal asymmetries were observed, with the maximum heat fluxes tending to fall on the lower outside panels. Heat deposition to the water-cooled guard limiters of an ion Bernstein wave antenna in CCT was measured during steady-state operation. Very strong asymmetries were observed. The heat distribution varied greatly with magnetic field. Copper heat flux sensors incorporating internal thermocouples were developed to measure plasma power deposition to exterior probe surfaces and heat removal from water -cooled interior surfaces. The resulting inverse heat conduction problem was solved using the function specification method. Cooling by an impinging liquid jet was investigated. One end of a cylindrical copper heat flux sensor was heated by a DC electrical arc and the other end was cooled by a low velocity water jet at 1 atm. Critical heat flux (CHF) values for the 55-80 ^circC sub-cooled free jets were typically 2.5 times published values for saturated free jets. For constrained jets, CHF values were about 20% lower. Heat deposition and heat removal in thick (3/4 inch diameter) cylindrical metal probes (SS304 or copper) inserted into a steady-state tokamak plasma were measured for a broad range of heat loads. The probes were cooled internally by a constrained jet of either air or water. Steady -state heat

  3. Cognitive and perceptual responses during passive heat stress in younger and older adults.

    PubMed

    Schlader, Zachary J; Gagnon, Daniel; Adams, Amy; Rivas, Eric; Cullum, C Munro; Crandall, Craig G

    2015-05-15

    We tested the hypothesis that attention, memory, and executive function are impaired to a greater extent in passively heat-stressed older adults than in passively heat-stressed younger adults. In a randomized, crossover design, 15 older (age: 69 ± 5 yr) and 14 younger (age: 30 ± 4 yr) healthy subjects underwent passive heat stress and time control trials. Cognitive tests (outcomes: accuracy and reaction time) from the CANTAB battery evaluated attention [rapid visual processing (RVP), choice reaction time (CRT)], memory [spatial span (SSP), pattern recognition memory (PRM)], and executive function [one touch stockings of Cambridge (OTS)]. Testing was undertaken on two occasions during each trial, at baseline and after internal temperature had increased by 1.0 ± 0.2°C or after a time control period. For tests that measured attention, reaction time during RVP and CRT was slower (P ≤ 0.01) in the older group. During heat stress, RVP reaction time improved (P < 0.01) in both groups. Heat stress had no effect (P ≥ 0.09) on RVP or CRT accuracy in either group. For tests that measured memory, accuracy on SSP and PRM was lower (P < 0.01) in the older group, but there was no effect of heat stress (P ≥ 0.14). For tests that measured executive function, overall, accuracy on OTS was lower, and reaction time was slower in the older group (P ≤ 0.05). Reaction time generally improved during heat stress, but there was no effect of heat stress on accuracy in either group. These data indicate that moderate increases in body temperature during passive heat stress do not differentially compromise cognitive function in younger and older adults. PMID:25786484

  4. Cognitive and perceptual responses during passive heat stress in younger and older adults

    PubMed Central

    Schlader, Zachary J.; Gagnon, Daniel; Adams, Amy; Rivas, Eric; Cullum, C. Munro

    2015-01-01

    We tested the hypothesis that attention, memory, and executive function are impaired to a greater extent in passively heat-stressed older adults than in passively heat-stressed younger adults. In a randomized, crossover design, 15 older (age: 69 ± 5 yr) and 14 younger (age: 30 ± 4 yr) healthy subjects underwent passive heat stress and time control trials. Cognitive tests (outcomes: accuracy and reaction time) from the CANTAB battery evaluated attention [rapid visual processing (RVP), choice reaction time (CRT)], memory [spatial span (SSP), pattern recognition memory (PRM)], and executive function [one touch stockings of Cambridge (OTS)]. Testing was undertaken on two occasions during each trial, at baseline and after internal temperature had increased by 1.0 ± 0.2°C or after a time control period. For tests that measured attention, reaction time during RVP and CRT was slower (P ≤ 0.01) in the older group. During heat stress, RVP reaction time improved (P < 0.01) in both groups. Heat stress had no effect (P ≥ 0.09) on RVP or CRT accuracy in either group. For tests that measured memory, accuracy on SSP and PRM was lower (P < 0.01) in the older group, but there was no effect of heat stress (P ≥ 0.14). For tests that measured executive function, overall, accuracy on OTS was lower, and reaction time was slower in the older group (P ≤ 0.05). Reaction time generally improved during heat stress, but there was no effect of heat stress on accuracy in either group. These data indicate that moderate increases in body temperature during passive heat stress do not differentially compromise cognitive function in younger and older adults. PMID:25786484

  5. Ethnic differences in thermoregulatory responses during resting, passive and active heating: application of Werner's adaptation model.

    PubMed

    Lee, Joo-Young; Wakabayashi, Hitoshi; Wijayanto, Titis; Hashiguchi, Nobuko; Saat, Mohamed; Tochihara, Yutaka

    2011-12-01

    For the coherent understanding of heat acclimatization in tropical natives, we compared ethnic differences between tropical and temperate natives during resting, passive and active heating conditions. Experimental protocols included: (1) a resting condition (an air temperature of 28°C with 50% RH), (2) a passive heating condition (28°C with 50% RH; leg immersion in a hot tub at a water temperature of 42°C), and (3) an active heating condition (32°C with 70% RH; a bicycle exercise). Morphologically and physically matched tropical natives (ten Malaysian males, MY) and temperate natives (ten Japanese males, JP) participated in all three trials. The results saw that: tropical natives had a higher resting rectal temperature and lower hand and foot temperatures at rest, smaller rise of rectal temperature and greater temperature rise in bodily extremities, and a lower sensation of thirst during passive and active heating than the matched temperate natives. It is suggested that tropical natives' homeostasis during heating is effectively controlled with the improved stability in internal body temperature and the increased capability of vascular circulation in extremities, with a lower thirst sensation. The enhanced stability of internal body temperature and the extended thermoregulatory capability of vascular circulation in the extremities of tropical natives can be interpreted as an interactive change to accomplish a thermal dynamic equilibrium in hot environments. These heat adaptive traits were explained by Wilder's law of initial value and Werner's process and controller adaptation model. PMID:21437607

  6. Tritium removal by CO{sub 2} laser heating

    SciTech Connect

    Skinner, C.H.; Kugel, H.; Mueller, D.; Doyle, B.L.; Wampler, W.R.

    1997-10-01

    Efficient techniques for rapid tritium removal will be necessary for ITER (International Thermonuclear Experimental Reactor) to meet its physics and engineering goals. One potential technique is transient surface heating by a scanning CO{sub 2} or Nd:YAG laser that would release tritium without the severe engineering difficulties of bulk heating of the vessel. The authors have modeled the heat propagation into a surface layer and find that a multi-kW/cm{sup 2} flux with an exposure time of order 10 msec is suitable to heat a 50 micron co-deposited layer to 1,000--2,000 degrees. Improved wall conditioning may be a significant side benefit. They identify remaining issues that need to be addressed experimentally.

  7. Tritium Removal by CO{sub 2} Laser Heating

    SciTech Connect

    B.L. Doyle; C.H. Skinner; D. Mueller; H. Kugel; W.R. Wampler

    1997-10-01

    Efficient techniques for rapid tritium removal will be necessary for ITER (International Thermonuclear Experimental Reactor) to meet its physics and engineering goals. One potential technique is transient surface heating by a scanning CO(subscript 2) or Nd:Yag laser that would release tritium without the severe engineering difficulties of bulk heating of the vessel. We have modeled the heat propagation into a surface layer and find that a multi-kW/cm(superscript2) flux with an exposure time of order 10 msec is suitable to heat a 50 micron co-deposited layer to 1,000-2,000 degrees. Improved wall conditioning may be a significant side benefit. We identify remaining issues that need to be addressed experimentally.

  8. Tritium removal by CO{sub 2} laser heating

    SciTech Connect

    Skinner, C.H.; Kugel, H.; Mueller, D.; Doyle, B.L.; Wampler, W.R.

    1997-10-01

    Efficient techniques for rapid tritium removal will be necessary for ITER to meet its physics and engineering goals. One potential technique is transient surface heating by a scanning CO{sub 2} or Nd:Yag laser that would release tritium without the severe engineering difficulties of bulk heating of the vessel. The authors have modeled the heat propagation into a surface layer and find that a multi-kW/cm{sup 2} flux with an exposure time of order 10 ms is suitable to heat a 50 micron co-deposited layer to 1,000--2,000 degrees. Improved wall conditioning may be a significant side benefit. They identify remaining issues that need to be addressed experimentally.

  9. Passive cigarette smoke, coal heating, and respiratory symptoms of nonsmoking women in China

    SciTech Connect

    Pope, C.A. III Brigham Young Univ., Provo, UT ); Xu, X. )

    1993-09-01

    In this study the authors evaluated data from a sample of 973 never-smoking women, ages 20-40, who worked in three similar textile mills in Anhui Province, China. They compared prevalence rates of respiratory symptoms across homes with and without coal heating and homes with different numbers of smokers. Multiple logistic regression models that controlled for age, job title, and mill of employment were also estimated. Respiratory symptoms were associated with combined exposure to passive cigarette smoke and coal heating. Effects of passive cigarette smoke and coal heating on respiratory symptoms appeared to be nearly additive, suggesting a dose-response relationship between respiratory symptoms and home indoor air pollution from these two sources. The prevalence of chest illness, cough, phlegm, and shortness of breath (but not wheeze) was significantly elevated for women living in homes with both smokers and coal heating.

  10. Study of thermosiphon and radiant panel passive heating systems for metal buildings

    SciTech Connect

    Biehl, F.A.; Schnurr, N.M.; Wray, W.O.

    1983-01-01

    A study of passive-heating systems appropriate for use on metal buildings is being conducted at Los Alamos National Laboratory for the Naval Civil Engineering Laboratory, Port Hueneme, California. The systems selected for study were chosen on the basis of their appropriateness for retrofit applications, although they are also suitable for new construction: simple radiant panels that communicate directly with the building interior and a backflow thermosiphon that provides heat indirectly.

  11. Function of human eccrine sweat glands during dynamic exercise and passive heat stress

    NASA Technical Reports Server (NTRS)

    Kondo, N.; Shibasaki, M.; Aoki, K.; Koga, S.; Inoue, Y.; Crandall, C. G.

    2001-01-01

    The purpose of this study was to identify the pattern of change in the density of activated sweat glands (ASG) and sweat output per gland (SGO) during dynamic constant-workload exercise and passive heat stress. Eight male subjects (22.8 +/- 0.9 yr) exercised at a constant workload (117.5 +/- 4.8 W) and were also passively heated by lower-leg immersion into hot water of 42 degrees C under an ambient temperature of 25 degrees C and relative humidity of 50%. Esophageal temperature, mean skin temperature, sweating rate (SR), and heart rate were measured continuously during both trials. The number of ASG was determined every 4 min after the onset of sweating, whereas SGO was calculated by dividing SR by ASG. During both exercise and passive heating, SR increased abruptly during the first 8 min after onset of sweating, followed by a slower increase. Similarly for both protocols, the number of ASG increased rapidly during the first 8 min after the onset of sweating and then ceased to increase further (P > 0.05). Conversely, SGO increased linearly throughout both perturbations. Our results suggest that changes in forearm sweating rate rely on both ASG and SGO during the initial period of exercise and passive heating, whereas further increases in SR are dependent on increases in SGO.

  12. Entirely passive heat-pipe apparatus capable of operating against gravity

    DOEpatents

    Koenig, D.R.

    1981-02-11

    The disclosure is directed to an entirely passive heat pipe apparatus capable of operating against gravity for vertical distances in the order of 3 to 7 and more. A return conduit into which an inert gas is introduced is used to lower the specific density of the working fluid so that it may be returned a greater vertical distance from condenser to evaporator.

  13. Method and apparatus for heat treating materials to remove contaminants

    SciTech Connect

    Evans, M.; Miller, D.H.

    1980-05-06

    A method and apparatus are disclosed for heat treating metals to remove contaminants. Contaminated scrap metal is fed into one end of a rotating inclined retort. Heat is applied to the retort as the scrap metal is conveyed therein to remove the contaminant, and the processed metal is discharged from the opposite end of the retort. Combustible waste gases generated through the processing are fed to an afterburner where the combustible gases are burned and are discharged from the afterburner into a stack. A portion of the hot combusted gases are returned from the stack to the discharge end of the retort to thereby minimize oxidation of the scrap metal being treated as well as conserving fuel.

  14. Modeling of Material Removal by Solid State Heat Capacity Lasers

    SciTech Connect

    Boley, C D; Rubenchik, A M

    2002-04-17

    Pulsed lasers offer the capability of rapid material removal. Here we present simulations of steel coupon tests by two solid state heat capacity lasers built at LLNL. Operating at 1.05 pm, these deliver pulse energies of about 80 J at 10 Hz, and about 500 J at 20 Hz. Each is flashlamp-pumped. The first laser was tested at LLNL, while the second laser has been delivered to HELSTF, White Sands Missile Range. Liquid ejection appears to be an important removal mechanism. We have modeled these experiments via a time-dependent code called THALES, which describes heat transport, melting, vaporization, and the hydrodynamics of liquid, vapor, and air. It was previously used, in a less advanced form, to model drilling by copper vapor lasers [1] . It was also used to model vaporization in beam dumps for a high-power laser [2]. The basic model is in 1D, while the liquid hydrodynamics is handled in 2D.

  15. Effect of plants on sunspace passive solar heating

    SciTech Connect

    Best, E.D.; McFarland, R.D.

    1985-01-01

    The effect of plants on sunspace thermal performance is investigated, based on experiments done in Los Alamos using two test rooms with attached sunspaces, which were essentially identical except for the presence of plants in one. Performance is related to plant transpiration, evaporation from the soil, condensation on the glazing and the absorbtance of solar energy by the lightweight leaves. Performance effects have been quantified by measurements of auxiliary heat consumption in the test rooms and analyzed by means of energy balance calculations. A method for estimating the transpiration rate is presented.

  16. Multiple pollutant removal using the condensing heat exchanger

    SciTech Connect

    Jankura, B. J.; Kudlac, G. A.; Bailey, R. T.

    1998-06-01

    The Integrated Flue Gas Treatment (IFGT) system is a new concept whereby a Teflon ® covered condensing heat exchanger is adapted to remove certain flue gas constituents, both particulate and gaseous, while recovering low level heat. The pollutant removal performance and durability of this device is the subject of a USDOE sponsored program to develop this technology. The program was conducted under contract to the United States Department of Energy's Fossil Energy Technology Center (DOE-FETC) and was supported by the Ohio Coal Development Office (OCDO) within the Ohio Department of Development, the Electric Power Research Institute's Environmental Control Technology Center (EPRI-ECTC) and Babcock and Wilcox - a McDermott Company (B&W). This report covers the results of the first phase of this program. This Phase I project has been a two year effort. Phase I includes two experimental tasks. One task dealt principally with the pollutant removal capabilities of the IFGT at a scale of about 1.2MWt. The other task studied the durability of the Teflon ® covering to withstand the rigors of abrasive wear by fly ash emitted as a result of coal combustion. The pollutant removal characteristics of the IFGT system were measured over a wide range of operating conditions. The coals tested included high, medium and low-sulfur coals. The flue gas pollutants studied included ammonia, hydrogen chloride, hydrogen fluoride, particulate, sulfur dioxide, gas phase and particle phase mercury and gas phase and particle phase trace elements. The particulate removal efficiency and size distribution was investigated. These test results demonstrated that the IFGT system is an effective device for both acid gas absorption and fine particulate collection. Although soda ash was shown to be the most effective reagent for acid gas absorption, comparative cost analyses suggested that magnesium enhanced lime was the most promising avenue for future study. The durability of the Teflon

  17. Control system analysis for off-peak auxiliary heating of passive solar systems

    SciTech Connect

    Murray, H.S.; Melsa, J.L.; Balcomb, J.D.

    1980-01-01

    A computer simulation method is presented for the design of an electrical auxiliary energy system for passive solar heated structures. The system consists of electrical mats buried in the ground underneath the structure. Energy is stored in the ground during utility off-peak hours and released passively to the heated enclosure. An optimal control strategy is used to determine the system design parameters of depth of mat placement and minimum instaled electrical heating capacity. The optimal control applies combinations of fixed duration energy pulses to the heater, which minimize the room temperature error-squared for each day, assuming advance knowledge of the day's weather. Various realizable control schemes are investigated in an attempt to find a system that approaches the performance of the optimal control system.

  18. Active charge/passive discharge solar heating systems: Thermal analysis and performance comparisons and performance comparisons

    NASA Astrophysics Data System (ADS)

    Swisher, J.

    1981-06-01

    This type of system combines liquid-cooled solar collector panels with a massive integral storage component that passively heats the building interior by radiation and free convection. The TRNSYS simulation program is used to evaluate system performance and to provide input for the development of a simplified analysis method. This method, which provides monthly calculations of delivered solar energy, is based on Klein's Phi-bar procedure and data from hourly TRNSYS simulations. The method can be applied to systems using a floor slab, a structural wall, or a water tank as the storage component. Important design parameters include collector area and orientation, building heat loss, collector and heat exchanger efficiencies, storage capacity, and storage to room coupling. Performance simulation results are used for comparisons with active and passive solar designs.

  19. Increased levels of FFA during passive heat loading after a 2-week repeated heat load in Koreans

    NASA Astrophysics Data System (ADS)

    Lee, Jeong Beom; Kim, Tae Wook

    2015-04-01

    The purpose of this study was to determine whether repeated heat load is closely related to circulating levels of free fatty acids (FFA) during repeated passive heat loading (PHL), defined as immersion of the lower body up to an umbilical level in hot water, 42 ± 0.5 °C (three times/week, 30 min/day) for 2 weeks. There were significant correlations between mean body temperature and FFA before and after repeated heat load ( p < 0.001, respectively), and the level of FFA was significantly higher after repeated heat load during PHL ( p < 0.01). The threshold of mean body temperature for lipolysis was lowered by repeated heat load and enhanced lipolysis during PHL. However, caution is needed for diabetic individuals.

  20. Natural/passive solar heating and cooling for poultry sheds

    SciTech Connect

    Abd El-Salam, E.M.

    1980-12-01

    Arid climates, as in Egypt and the Middle-East regions, are characterized by large durinal and seasonal temperature variation coupled with clear skies and ample sunshine duration. Partial stabilization of indoor thermal environment in habitation is of great comfort for human and have large effects on animals or birds productivities. In case of poultry or animal sheds, can have some economical turn over in terms of increased egg or animal productivity and reduction of mortality rates if their indoor thermal environment is favorably controlled. Poultry birds are sensitive to changes of ambient temperatures, humidity and other environmental variables. This investigation describes an unconventional method of maintaining moderate thermal environment within poultry sheds by using the roof for storage of heat and coolness in appropriate seasons. During winter, underground water is circulated through specially designed pipe matrix imbeded in the roof slab and through radiant wall panels.

  1. Shellfish mariculture facility which employs passive solar heating and heat pump systems. Performance and cost analysis study. Final report

    SciTech Connect

    Zoto, G.A.; Krabach, M.H.

    1984-06-01

    This report incorporates operations data such as clam growth rates, clam biomass buildup, water volume, and algal food requirements compiled while developing a year-round production schedule for production of hard clam seed. The facility includes a passive solar hatchery and heat pump. Three major areas which affect development of energy-efficient mariculture are addressed: biological operation parameters, energy requirements, and system economics. (LEW)

  2. Damp and dry heat degradation of thermal oxide passivation of p+ silicon

    NASA Astrophysics Data System (ADS)

    Thomson, Andrew; Gardner, Matthew; McIntosh, Keith; Shalav, Avi; Bullock, James

    2014-03-01

    Thermal SiO2 passivates both moderately and heavily doped silicon surfaces irrespective of the dopant type, which is advantageous in high-efficiency solar cell designs. Commercial photovoltaic cells are submitted to accelerated ageing tests, such as damp-heat exposure, to ensure they maintain their performance for at least 20 yr. We find damp-heat exposure causes a severe and rapid degradation of thermal SiO2 passivation on p+ silicon surfaces. The reaction is so severe that the diffused-region recombination in the degraded state is limited by the diffusion of minority carriers to the Si-SiO2 interface not the density of interface defects Dit. Certainly, this effect renders the thermal-oxide passivation useless if employed on a solar cell. To study the cause of the degradation, we also test the effects of storage in dry heat and room ambient conditions. Examination of the rate of degradation in the tested storage conditions in comparison with modelled diffusion of moisture in SiO2, we find a significant correlation between the time dependent J0e and moisture supplied to the interface, leading us to the conclusion that moisture ingression and subsequent reaction at the SiO2-Si interface are the cause of both damp-heat and room- ambient degradation.

  3. Liquid metal cooled nuclear reactors with passive cooling system

    DOEpatents

    Hunsbedt, Anstein; Fanning, Alan W.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of cooling medium flow circuits which cooperate to remove and carry heat away from the fuel core upon loss of the normal cooling flow circuit to areas external thereto.

  4. Design and testing of a passive, feedback-controlled, variable conductance heat pipe

    NASA Technical Reports Server (NTRS)

    Schlitt, K. R.

    1973-01-01

    A passive feedback system, which stabilizes the heat source temperature (T sub s) of a gas loaded heat pipe, was designed and tested. The control of T sub s is accomplished by an auxiliary liquid that senses the heat source and actuates a metal bellows system due to the liquid's thermal expansion. The movement of the bellows varies the gas reservoir volume and leads to a corresponding change of the condensation area of the heat pipe. With methanol as the heat pipe working fluid and perfluoro-n-pentane as the auxiliary liquid, the control capability was found to be T sub s = 31.5 + or - 1.5 C in a power range from 3 to 30 W, compared to T sub s = 33 + or - 3 C with methanol as auxiliary liquid. The change in T sub s was 35 + or - 5.5 C with the bellows held in the closed position.

  5. Temperature and blood flow distribution in the human leg during passive heat stress

    PubMed Central

    Chiesa, Scott T.; Trangmar, Steven J.

    2016-01-01

    The influence of temperature on the hemodynamic adjustments to direct passive heat stress within the leg's major arterial and venous vessels and compartments remains unclear. Fifteen healthy young males were tested during exposure to either passive whole body heat stress to levels approaching thermal tolerance [core temperature (Tc) + 2°C; study 1; n = 8] or single leg heat stress (Tc + 0°C; study 2; n = 7). Whole body heat stress increased perfusion and decreased oscillatory shear index in relation to the rise in leg temperature (Tleg) in all three major arteries supplying the leg, plateauing in the common and superficial femoral arteries before reaching severe heat stress levels. Isolated leg heat stress increased arterial blood flows and shear patterns to a level similar to that obtained during moderate core hyperthermia (Tc + 1°C). Despite modest increases in great saphenous venous (GSV) blood flow (0.2 l/min), the deep venous system accounted for the majority of returning flow (common femoral vein 0.7 l/min) during intense to severe levels of heat stress. Rapid cooling of a single leg during severe whole body heat stress resulted in an equivalent blood flow reduction in the major artery supplying the thigh deep tissues only, suggesting central temperature-sensitive mechanisms contribute to skin blood flow alone. These findings further our knowledge of leg hemodynamic responses during direct heat stress and provide evidence of potentially beneficial vascular alterations during isolated limb heat stress that are equivalent to those experienced during exposure to moderate levels of whole body hyperthermia. PMID:26823344

  6. Temperature and blood flow distribution in the human leg during passive heat stress.

    PubMed

    Chiesa, Scott T; Trangmar, Steven J; González-Alonso, José

    2016-05-01

    The influence of temperature on the hemodynamic adjustments to direct passive heat stress within the leg's major arterial and venous vessels and compartments remains unclear. Fifteen healthy young males were tested during exposure to either passive whole body heat stress to levels approaching thermal tolerance [core temperature (Tc) + 2°C; study 1; n = 8] or single leg heat stress (Tc + 0°C; study 2; n = 7). Whole body heat stress increased perfusion and decreased oscillatory shear index in relation to the rise in leg temperature (Tleg) in all three major arteries supplying the leg, plateauing in the common and superficial femoral arteries before reaching severe heat stress levels. Isolated leg heat stress increased arterial blood flows and shear patterns to a level similar to that obtained during moderate core hyperthermia (Tc + 1°C). Despite modest increases in great saphenous venous (GSV) blood flow (0.2 l/min), the deep venous system accounted for the majority of returning flow (common femoral vein 0.7 l/min) during intense to severe levels of heat stress. Rapid cooling of a single leg during severe whole body heat stress resulted in an equivalent blood flow reduction in the major artery supplying the thigh deep tissues only, suggesting central temperature-sensitive mechanisms contribute to skin blood flow alone. These findings further our knowledge of leg hemodynamic responses during direct heat stress and provide evidence of potentially beneficial vascular alterations during isolated limb heat stress that are equivalent to those experienced during exposure to moderate levels of whole body hyperthermia. PMID:26823344

  7. Methods of Helium Injection and Removal for Heat Transfer Augmentation

    NASA Technical Reports Server (NTRS)

    Haight, Harlan; Kegley, Jeff; Bourdreaux, Meghan

    2008-01-01

    While augmentation of heat transfer from a test article by helium gas at low pressures is well known, the method is rarely employed during space simulation testing because the test objectives usually involve simulation of an orbital thermal environment. Test objectives of cryogenic optical testing at Marshall Space Flight Center's X-ray Cryogenic Facility (XRCF) have typically not been constrained by orbital environment parameters. As a result, several methods of helium injection have been utilized at the XRCF since 1999 to decrease thermal transition times. A brief synopsis of these injection (and removal) methods including will be presented.

  8. Methods of Helium Injection and Removal for Heat Transfer Augmentation

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey

    2008-01-01

    While augmentation of heat transfer from a test article by helium gas at low pressures is well known, the method is rarely employed during space simulation testing because the test objectives are to simulate an orbital thermal environment. Test objectives of cryogenic optical testing at Marshall Space Flight Center's X-ray Calibration Facility (XRCF) have typically not been constrained by orbital environment parameters. As a result, several methods of helium injection have been utilized at the XRCF since 1999 to decrease thermal transition times. A brief synopsis of these injection (and removal) methods including will be presented.

  9. System Study: Residual Heat Removal 1998–2013

    SciTech Connect

    Schroeder, John Alton

    2015-02-01

    This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and post-trip shutdown-cooling) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant trends were identified in the RHR results.

  10. Cooling-load implications for residential passive-solar-heating systems

    SciTech Connect

    Jones, R.W.; McFarland, R.D.

    1983-01-01

    Ongoing research on quantifying the cooling loads in residential buildings, particularly buildings with passive solar heating systems, is described, along with the computer simulation model used for calculating cooling loads. A sample of interim results is also presented. The objective of the research is to develop a simple analysis method, useful early in design, to estimate the annual cooling energy requirement of a given building.

  11. Effects of hormone replacement therapy on hemodynamic responses of postmenopausal women to passive heating.

    PubMed

    Dunbar, S L; Kenney, W L

    2000-07-01

    To examine the influence of chronic hormone replacement therapy (HRT) on the central and peripheral cardiovascular responses of postmenopausal women to direct passive heating, seven women taking estrogen replacement therapy, seven women taking estrogen and progesterone therapy, and seven women not taking HRT were passively heated with water-perfused suits to their individual limit of thermal tolerance. Measurements included heart rate (HR), cardiac output, blood pressure, skin blood flow, splanchnic blood flow, renal blood flow, esophageal temperature, and mean skin temperature. Cardiac output was higher in women taking estrogen and progesterone therapy than in women not taking HRT (7.12 +/- 0.70 vs. 5.02 +/- 0. 57 l/min at the limit of thermal tolerance, respectively; P < 0.05) because of a higher HR. However, when the HR data were plotted as a percentage of the maximum HR or percentage of HR reserve, there were no differences among the three groups of women. Neither splanchnic nor renal blood flow differed among the groups of women. These data suggest that HRT has little effect on the cardiovascular responses to direct passive heating. PMID:10904040

  12. Cleaning and passivation of copper surfaces to remove surface radioactivity and prevent oxide formation

    SciTech Connect

    Hoppe, Eric W.; Seifert, Allen; Aalseth, Craig E.; Bachelor, Paula P.; Day, Anthony R.; Edwards, Danny J.; Hossbach, Todd W.; Litke, Kevin E.; McIntyre, Justin I.; Miley, Harry S.; Schulte, Shannon M.; Smart, John E.; Warren, Glen A.

    2007-08-21

    High-purity copper is an attractive material for constructing ultra-low-background radiation measurement devices. Many low-background experiments using high-purity copper have indicated surface contamination emerges as the dominant background. Radon daughters plate out on exposed surfaces, leaving a residual 210Pb background that is difficult to avoid. Dust is also a problem; even under cleanroom conditions, the amount of U and Th deposited on surfaces can represent the largest remaining background. To control these backgrounds, a copper cleaning chemistry has been developed. Designed to replace an effective, but overly aggressive concentrated nitric acid etch, this peroxide-based solution allows for a more controlled cleaning of surfaces. The acidified hydrogen peroxide solution will generally target the Cu+/Cu2+ species which are the predominant surface participants, leaving the bulk of copper metal intact. This preserves the critical tolerances of parts and eliminates significant waste disposal issues. Accompanying passivation chemistry has also been developed that protects copper surfaces from oxidation. Using a high-activity polonium surface spike, the most difficult-to-remove daughter isotope of radon, the performance of these methods are quantified. © 2001 Elsevier Science. All rights reserved

  13. Effect of passive heat stress on arterial stiffness in smokers versus non-smokers

    NASA Astrophysics Data System (ADS)

    Moyen, N. E.; Ganio, M. S.; Burchfield, J. M.; Tucker, M. A.; Gonzalez, M. A.; Dougherty, E. K.; Robinson, F. B.; Ridings, C. B.; Veilleux, J. C.

    2016-04-01

    In non-smokers, passive heat stress increases shear stress and vasodilation, decreasing arterial stiffness. Smokers, who reportedly have arterial dysfunction, may have similar improvements in arterial stiffness with passive heat stress. Therefore, we examined the effects of an acute bout of whole-body passive heat stress on arterial stiffness in smokers vs. non-smokers. Thirteen smokers (8.8 ± 5.5 [median = 6] cigarettes per day for >4 years) and 13 non-smokers matched for age, mass, height, and exercise habits (27 ± 8 years; 78.8 ± 15.4 kg; 177.6 ± 6.7 cm) were passively heated to 1.5 °C core temperature ( T C) increase. At baseline and each 0.5 °C T C increase, peripheral (pPWV) and central pulse wave velocity (cPWV) were measured via Doppler ultrasound. No differences existed between smokers and non-smokers for any variables (all p > 0.05), except cPWV slightly increased from baseline (526.7 ± 81.7 cm · s-1) to 1.5 °C Δ T C (579.7 ± 69.8 cm · s-1; p < 0.005), suggesting heat stress acutely increased central arterial stiffness. pPWV did not change with heating (grand mean: baseline = 691.9 ± 92.9 cm · s-1; 1.5 °C Δ T C = 691.9 ± 79.5 cm · s-1; p > 0.05). Changes in cPWV and pPWV during heating correlated ( p < 0.05) with baseline PWV in smokers (cPWV: r = -0.59; pPWV: r = -0.62) and non-smokers (cPWV: r = -0.45; pPWV: r = -0.77). Independent of smoking status, baseline stiffness appears to mediate the magnitude of heating-induced changes in arterial stiffness.

  14. Effect of passive heat stress on arterial stiffness in smokers versus non-smokers.

    PubMed

    Moyen, N E; Ganio, M S; Burchfield, J M; Tucker, M A; Gonzalez, M A; Dougherty, E K; Robinson, F B; Ridings, C B; Veilleux, J C

    2016-04-01

    In non-smokers, passive heat stress increases shear stress and vasodilation, decreasing arterial stiffness. Smokers, who reportedly have arterial dysfunction, may have similar improvements in arterial stiffness with passive heat stress. Therefore, we examined the effects of an acute bout of whole-body passive heat stress on arterial stiffness in smokers vs. non-smokers. Thirteen smokers (8.8 ± 5.5 [median = 6] cigarettes per day for > 4 years) and 13 non-smokers matched for age, mass, height, and exercise habits (27 ± 8 years; 78.8 ± 15.4 kg; 177.6 ± 6.7 cm) were passively heated to 1.5 °C core temperature (T C) increase. At baseline and each 0.5 °C T C increase, peripheral (pPWV) and central pulse wave velocity (cPWV) were measured via Doppler ultrasound. No differences existed between smokers and non-smokers for any variables (all p >  .05), except cPWV slightly increased from baseline (526.7 ± 81.7 cm · s(-1)) to 1.5 °C ΔT C (579.7 ± 69.8 cm · s(-1); p < 0.005), suggesting heat stress acutely increased central arterial stiffness. pPWV did not change with heating (grand mean: baseline = 691.9 ± 92.9 cm · s(-1); 1.5 °C ΔT C = 691.9 ± 79.5 cm · s(-1); p > 0.05). Changes in cPWV and pPWV during heating correlated (p < 0.05) with baseline PWV in smokers (cPWV: r = -0.59; pPWV: r = -0.62) and non-smokers (cPWV: r = -0.45; pPWV: r = -0.77). Independent of smoking status, baseline stiffness appears to mediate the magnitude of heating-induced changes in arterial stiffness. PMID:26266482

  15. Tritium Removal by Laser Heating and Its Application to Tokamaks

    SciTech Connect

    C.H. Skinner; C.A. Gentile; G. Guttadora; A. Carpe; S. Langish; K.M. Young; M. Nishi; W. Shu

    2001-11-16

    A novel laser heating technique has recently been applied to removing tritium from carbon tiles that had been exposed to deuterium-tritium (DT) plasmas in the Tokamak Test Fusion Reactor (TFTR). A continuous wave neodymium laser, of power up to 300 watts, was used to heat the surface of the tiles. The beam was focused to an intensity, typically 8 kW/cm{sup 2}, and rapidly scanned over the tile surface by galvanometer-driven scanning mirrors. Under the laser irradiation, the surface temperature increased dramatically, and temperatures up to 2,300 degrees C were recorded by an optical pyrometer. Tritium was released and circulated in a closed-loop system to an ionization chamber that measured the tritium concentration. Most of the tritium (up to 84%) could be released by the laser scan. This technique appears promising for tritium removal in a next-step DT device as it avoids oxidation, the associated deconditioning of the plasma facing surfaces, and the expense of processing large quantities of tritium oxide. Some engineering aspects of the implementation of this method in a next-step fusion device will be discussed.

  16. Gas-Cooled Fast Reactor (GFR) Decay Heat Removal Concepts

    SciTech Connect

    K. D. Weaver; L-Y. Cheng; H. Ludewig; J. Jo

    2005-09-01

    Current research and development on the Gas-Cooled Fast Reactor (GFR) has focused on the design of safety systems that will remove the decay heat during accident conditions, ion irradiations of candidate ceramic materials, joining studies of oxide dispersion strengthened alloys; and within the Advanced Fuel Cycle Initiative (AFCI) the fabrication of carbide fuels and ceramic fuel matrix materials, development of non-halide precursor low density and high density ceramic coatings, and neutron irradiation of candidate ceramic fuel matrix and metallic materials. The vast majority of this work has focused on the reference design for the GFR: a helium-cooled, direct power conversion system that will operate with an outlet temperature of 850ºC at 7 MPa. In addition to the work being performed in the United States, seven international partners under the Generation IV International Forum (GIF) have identified their interest in participating in research related to the development of the GFR. These are Euratom (European Commission), France, Japan, South Africa, South Korea, Switzerland, and the United Kingdom. Of these, Euratom (including the United Kingdom), France, and Japan have active research activities with respect to the GFR. The research includes GFR design and safety, and fuels/in-core materials/fuel cycle projects. This report is a compilation of work performed on decay heat removal systems for a 2400 MWt GFR during this fiscal year (FY05).

  17. Passivation of organic light emitting diode anode grid lines by pulsed Joule heating

    NASA Astrophysics Data System (ADS)

    Janka, M.; Gierth, R.; Rubingh, J.-E.; Abendroth, M.; Eggert, M.; Moet, D. J. D.; Lupo, D.

    2015-09-01

    We report the self-aligned passivation of a current distribution grid for an organic light emitting diode (OLED) anode using a pulsed Joule heating method to align the passivation layer accurately on the metal grid. This method involves passing an electric current through the grid to cure a polymer dielectric. Uncured polymer is then rinsed away, leaving a patterned dielectric layer that conforms to the shape of the grid lines. To enhance the accuracy of the alignment, heat conduction into the substrate and the transparent electrode is limited by using short current pulses instead of a constant current. Excellent alignment accuracy of the dielectric layer on printed metal grid lines has been achieved, with a typical 4-μm dielectric overhang. In addition to good accuracy, pulsed Joule heating significantly cuts down process time and energy consumption compared to heating with a constant current. The feasibility of using a printed current distribution grid and Joule heating was demonstrated in an OLED device.

  18. Energy-conserving passive solar multi-family retrofit projects. Cycle 5, category 1: HUD Solar Heating and Cooling Demonstration Program

    NASA Astrophysics Data System (ADS)

    1981-10-01

    A total of 14 passive solar retrofit buildings are described. The concept of passive solar energy and the various types of passive systems found in the Cycle 5 projects are discussed. Each of the 14 solar designs is described, and some of the key points raised in the discussion of passive concepts are illustrated. Each project description cites the location of the passive solar home and presents the following information: grantee/builder, designer, solar designer, price, number of units, net heated area, heat load, degree days, solar fraction of the total heat load, and auxiliary heat required. Project descriptions also include data on recognition factors (the five passive elements necessary for a complete passive system), the type of auxiliary heating system used in the building, the solar water heating system (if any), and the passive cooling techniques used (if any).

  19. Combined Active and Passive Solar Space Heating and Solar Hot Water Systems for an Elementary School in Boise, Idaho.

    ERIC Educational Resources Information Center

    Smull, Neil A.; Armstrong, Gerald L.

    1979-01-01

    Amity Elementary School in Boise, Idaho, features a solar space heating and domestic hot water system along with an earth covering to accommodate the passive aspects of energy conservation. (Author/MLF)

  20. Evaluation of a Passive Heat Exchanger Based Cooling System for Fuel Cell Applications

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.; Burke, Kenneth A.

    2011-01-01

    Fuel cell cooling is conventionally performed with an actively controlled, dedicated coolant loop that exchanges heat with a separate external cooling loop. To simplify this system the concept of directly cooling a fuel cell utilizing a coolant loop with a regenerative heat exchanger to preheat the coolant entering the fuel cell with the coolant exiting the fuel cell was analyzed. The preheating is necessary to minimize the temperature difference across the fuel cell stack. This type of coolant system would minimize the controls needed on the coolant loop and provide a mostly passive means of cooling the fuel cell. The results indicate that an operating temperature of near or greater than 70 C is achievable with a heat exchanger effectiveness of around 90 percent. Of the heat exchanger types evaluated with the same type of fluid on the hot and cold side, a counter flow type heat exchanger would be required which has the possibility of achieving the required effectiveness. The number of heat transfer units required by the heat exchanger would be around 9 or greater. Although the analysis indicates the concept is feasible, the heat exchanger design would need to be developed and optimized for a specific fuel cell operation in order to achieve the high effectiveness value required.

  1. Method for passive cooling liquid metal cooled nuclear reactors, and system thereof

    DOEpatents

    Hunsbedt, Anstein; Busboom, Herbert J.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel.

  2. Effect of short-term exercise-heat acclimation on ventilatory and cerebral blood flow responses to passive heating at rest in humans.

    PubMed

    Fujii, Naoto; Tsuji, Bun; Honda, Yasushi; Kondo, Narihiko; Nishiyasu, Takeshi

    2015-09-01

    Hyperthermia induces hyperventilation and cerebral hypoperfusion in resting humans. We tested the hypothesis that short-term exercise-heat acclimation would alleviate those effects. Twenty healthy male subjects were divided into two groups that performed exercise training in the heat (TR-HEAT, n = 10) or cold (TR-COLD, n = 10). Before and after the training, the subjects in both groups participated in passive-heat tests at rest. Training was performed at 37°C (TR-HEAT) or 10°C (TR-COLD) and entailed four 20-min bouts of cycling at 50% peak oxygen uptake separated by 10-min recoveries daily for 6 consecutive days. After TR-HEAT, esophageal temperature was lowered when measured before and during passive heating, as was the esophageal temperature threshold for cutaneous active vasodilation, whereas plasma volume was increased (all P < 0.05). These traditional indices of successful heat acclimation were not all induced by TR-COLD (all P > 0.05). TR-HEAT had no significant effect on passive heating-induced increases in minute ventilation, even when evaluated as the esophageal temperature threshold for increases in minute ventilation and the slope relating minute ventilation to esophageal temperature (all P > 0.05). By contrast, TR-HEAT attenuated the passive heating-induced reduction in the cerebral vascular conductance index (middle cerebral artery mean blood velocity/mean arterial pressure) (all P < 0.05). TR-COLD did not attenuate the increase in minute ventilation or the decrease in the cerebral vascular conductance index observed during passive heating (all P > 0.05). These data suggest that in resting heated humans, short-term heat acclimation achieved through moderate-intensity exercise training (i.e., 50% peak oxygen uptake) in the heat does not influence hyperthermia-induced hyperventilation, but it does potentially attenuate cerebral hypoperfusion. PMID:26159763

  3. Advanced phase change materials and systems for solar passive heating and cooling of residential buildings

    SciTech Connect

    Salyer, I.O.; Sircar, A.K.; Dantiki, S.

    1988-01-01

    During the last three years under the sponsorship of the DOE Solar Passive Division, the University of Dayton Research Institute (UDRI) has investigated four phase change material (PCM) systems for utility in thermal energy storage for solar passive heating and cooling applications. From this research on the basis of cost, performance, containment, and environmental acceptability, we have selected as our current and most promising series of candidate phase change materials, C-15 to C-24 linear crystalline alkyl hydrocarbons. The major part of the research during this contract period was directed toward the following three objectives. Find, test, and develop low-cost effective phase change materials (PCM) that melt and freeze sharply in the comfort temperature range of 73--77{degree}F for use in solar passive heating and cooling of buildings. Define practical materials and processes for fire retarding plasterboard/PCM building products. Develop cost-effective methods for incorporating PCM into building construction materials (concrete, plasterboard, etc.) which will lead to the commercial manufacture and sale of PCM-containing products resulting in significant energy conservation.

  4. Passive Gas-Gap Heat Switches for Use in Adiabatic Demagnetization Refrigerators

    NASA Technical Reports Server (NTRS)

    Shirron, P. J.; Canavan, E. R.; DiPirro, M. J.; Jackson, M.; Panek, J.; Tuttle, J. G.; Krebs, Carolyn (Technical Monitor)

    2001-01-01

    We have designed, built, and tested a gas gap heat switch that works passively, without the need for a separate, thermally activated getter. This switch uses He-3 condensed as a thin film on alternating plates of copper. The switch is thermally conductive at temperatures above about 0.2 K, and is insulating if either end of the switch is below about 0.15 K. The "on" conductance (7 mW/K at 0.25K) is limited by the surface area and gap between the copper leaves, the saturated vapor pressure of the He-3, and the Kapitza boundary resistance between the He-3 and the copper. The "off" conductance is determined by the helium containment shell which physically supports the two conductive ends. We have also designed and are building passive gas gap heat switches which will passively turn off near 1 K and 4 K. For these switches we rely on the rapidly changing vapor pressure of He-4 above neon or copper substrates, respectively, when the coverage is less than one monolayer. The different binding energies of the He-4 to the neon or copper give rise to the different temperatures where the switches transition between the on and off states.

  5. System Study: Residual Heat Removal 1998-2014

    SciTech Connect

    Schroeder, John Alton

    2015-12-01

    This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and post-trip shutdown-cooling) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trends were identified in the RHR results. A highly statistically significant decreasing trend was observed for the RHR injection mode start-only unreliability. Statistically significant decreasing trends were observed for RHR shutdown cooling mode start-only unreliability and RHR shutdown cooling model 24-hour unreliability.

  6. Enhancing ultra-high CPV passive cooling using least-material finned heat sinks

    SciTech Connect

    Micheli, Leonardo Mallick, Tapas K.; Fernandez, Eduardo F.; Almonacid, Florencia; Reddy, K. S.

    2015-09-28

    Ultra-high concentrating photovoltaic (CPV) systems aim to increase the cost-competiveness of CPV by increasing the concentrations over 2000 suns. In this work, the design of a heat sink for ultra-high concentrating photovoltaic (CPV) applications is presented. For the first time, the least-material approach, widely used in electronics to maximize the thermal dissipation while minimizing the weight of the heat sink, has been applied in CPV. This method has the potential to further decrease the cost of this technology and to keep the multijunction cell within the operative temperature range. The designing procedure is described in the paper and the results of a thermal simulation are shown to prove the reliability of the solution. A prediction of the costs is also reported: a cost of 0.151$/W{sub p} is expected for a passive least-material heat sink developed for 4000x applications.

  7. Metal Removal Efficiency And Ecotoxicological Assessment Of Field-Scale Passive Treatment Biochemical Reactors

    EPA Science Inventory

    Anaerobic biochemical reactors (BCRs) are useful for removing metals from mining-impacted water at remote sites. Removal processes include sorption and precipitation of metal sulfides, carbonates, and hydroxides. A question of interest is whether BCRs remove aquatic toxicity. ...

  8. Metal removal efficiency and ecotoxicological assessment of field-scale passive treatment biochemical reactors

    EPA Science Inventory

    Anaerobic biochemical reactors (BCRs) are useful for removing metals from mining-impacted water (MIW) at remote sites. Removal processes include sorption and precipitation of metal sulfides, carbonates and hydroxides. A question of interest is whether BCRs remove aquatic toxicit...

  9. The use of segregated heat sink structures to achieve enhanced passive cooling for outdoor wireless devices

    NASA Astrophysics Data System (ADS)

    O'Flaherty, K.; Punch, J.

    2014-07-01

    Environmental standards which govern outdoor wireless equipment can stipulate stringent conditions: high solar loads (up to 1 kW/m2), ambient temperatures as high as 55°C and negligible wind speeds (0 m/s). These challenges result in restrictions on power dissipation within a given envelope, due to the limited heat transfer rates achievable with passive cooling. This paper addresses an outdoor wireless device which features two segregated heat sink structures arranged vertically within a shielded chimney structure: a primary sink to cool temperature-sensitive components; and a secondary sink for high power devices. Enhanced convective cooling of the primary sink is achieved due to the increased mass flow within the chimney generated by the secondary sink. An unshielded heat sink was examined numerically, theoretically and experimentally, to verify the applicability of the methods employed. Nusselt numbers were compared for three cases: an unshielded heat sink; a sink located at the inlet of a shield; and a primary heat sink in a segregated structure. The heat sink, when placed at the inlet of a shield three times the length of the sink, augmented the Nusselt number by an average of 64% compared to the unshielded case. The Nusselt number of the primary was found to increase proportionally with the temperature of the secondary sink, and the optimum vertical spacing between the primary and secondary sinks was found to be close to zero, provided that conductive transfer between the sinks was suppressed.

  10. Simulations of polarization dependent contrast during the diurnal heating cycle for passive millimeter-wave imagery

    NASA Astrophysics Data System (ADS)

    Wilson, John P.; Murakowski, Maciej; Schuetz, Christopher A.; Prather, Dennis W.

    2013-09-01

    Passive millimeter-wave (mmW) sensors are especially suited to persistent surveillance applications due to their ability to operate during day/night conditions and through transient atmospheric obscurants such as clouds, rain and fog. The contrast of targets will change throughout a diurnal heating cycle and this change will be polarization dependent. Simulations are presented from a ray tracing program developed for the mmW regime that has been modified to account for polarization information. Results are shown demonstrating periods during the day when the contrast of certain targets drop to zero for a linear polarization state while the orthogonal state still maintains a high contrast.

  11. Analysis of a passive heat sink for temperature stabilization of high-power LED bulbs

    NASA Astrophysics Data System (ADS)

    Balvís, Eduardo; Bendaña, Ricardo; Michinel, Humberto; Fernández de Córdoba, Pedro; Paredes, Angel

    2015-04-01

    In this paper we present a numerical analysis and experimental measurements of the temperature stabilization of high-power LED chips that we have obtained by employing an aluminum passive heat sink, designed to be used in a compact light bulb configuration. We demonstrate that our system keeps the temperature of the LED chip well-below 70° C yielding long-term operation of the device. Our simulations have been performed for a low-cost device ready to install in public streetlights. The experimental measurements performed in different configurations show a nice agreement with the numerical calculations.

  12. An analysis of manganese as an indicator for heavy metal removal in passive treatment using laboratory spent mushroom compost columns

    SciTech Connect

    Jacobson, B.A.; Unz, R.F.; Dempsey, B.A.

    1999-07-01

    The National Pollution Discharge Elimination System (NPDES) dictates removal of manganese in mine drainage to less than 4 mg/1 daily or less than 2 mg/1 on a monthly average. Owing to its high solubility at low and circumneutral pH, removal of manganese is often the most difficult of the NPDES discharge standards. This has lead to the use of Mn(II) as a surrogate for metal removal. However, recent studies concluded that zinc or nickel may be more appropriate indicators for removal of other metals. Previous field studies showed zinc removal to be highly correlated to the removal of copper, cobalt, and nickel in a sulfate reducing subsurface loaded wetland, whereas manganese removal was poorly correlated. The objective of this study was to evaluate zinc and manganese retention under sulfate reducing conditions in bench scale columns containing fresh spent mushroom compost. Column effluent data were analyzed using an EPA geochemical computer model (MINTEQ) over the pH range of 6.0 to 6.8. Under these conditions, zinc and manganese displayed distinctly reactivities. Zn(II) was supersaturated with respect to ZnS{sub s} and the Zn(HS){sub 2}{degree} and Zn(HS){sub 3}{sup minus} complexes dominated solubility. Soluble zinc concentrations were inversely correlated to sulfide. Mn(II) remained as soluble Mn{sup +2}. During early column operation at pH > 7, MnCO{sup 3(s)} was supersaturated. Manganese concentrations did not correlate with pH or sulfide. Given these fundamental differences in removal mechanisms between Zn and Mn under sulfate reducing conditions, the use of manganese removal as a surrogate for heavy metal removal in passive treatment of mine drainage seems unjustified.

  13. Passive body heating improves sleep patterns in female patients with fibromyalgia

    PubMed Central

    Silva, Andressa; de Queiroz, Sandra Souza; Andersen, Monica Levy; Mônico-Neto, Marcos; da Silveira Campos, Raquel Munhoz; Roizenblatt, Suely; Tufik, Sergio; de Mello, Marco Túlio

    2013-01-01

    OBJECTIVE: To assess the effect of passive body heating on the sleep patterns of patients with fibromyalgia. METHODS: Six menopausal women diagnosed with fibromyalgia according to the criteria determined by the American College of Rheumatology were included. All women underwent passive immersion in a warm bath at a temperature of 36±1°C for 15 sessions of 30 minutes each over a period of three weeks. Their sleep patterns were assessed by polysomnography at the following time-points: pre-intervention (baseline), the first day of the intervention (acute), the last day of the intervention (chronic), and three weeks after the end of the intervention (follow-up). Core body temperature was evaluated by a thermistor pill during the baseline, acute, chronic, and follow-up periods. The impact of this treatment on fibromyalgia was assessed via a specific questionnaire termed the Fibromyalgia Impact Questionnaire. RESULTS: Sleep latency, rapid eye movement sleep latency and slow wave sleep were significantly reduced in the chronic and acute conditions compared with baseline. Sleep efficiency was significantly increased during the chronic condition, and the awakening index was reduced at the chronic and follow-up time points relative to the baseline values. No significant differences were observed in total sleep time, time in sleep stages 1 or 2 or rapid eye movement sleep percentage. The core body temperature and Fibromyalgia Impact Questionnaire responses did not significantly change over the course of the study. CONCLUSION: Passive body heating had a positive effect on the sleep patterns of women with fibromyalgia. PMID:23525306

  14. Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures

    PubMed Central

    Smitka, Martin; Malcho, Milan

    2014-01-01

    Loop heat pipes (LHPs) are used in many branches of industry, mainly for cooling of electrical elements and systems. The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work was to develop porous structures from copper and nickel powder with different grain sizes. For experiment copper powder with grain size of 50 and 100 μm and nickel powder with grain size of 10 and 25 μm were used. Analysis of these porous structures and LHP design are described in the paper. And the measurements' influences of porous structures in LHP on heat removal from the insulated gate bipolar transistor (IGBT) have been made. PMID:24959622

  15. Heat removal from bipolar transistor by loop heat pipe with nickel and copper porous structures.

    PubMed

    Nemec, Patrik; Smitka, Martin; Malcho, Milan

    2014-01-01

    Loop heat pipes (LHPs) are used in many branches of industry, mainly for cooling of electrical elements and systems. The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work was to develop porous structures from copper and nickel powder with different grain sizes. For experiment copper powder with grain size of 50 and 100 μm and nickel powder with grain size of 10 and 25 μm were used. Analysis of these porous structures and LHP design are described in the paper. And the measurements' influences of porous structures in LHP on heat removal from the insulated gate bipolar transistor (IGBT) have been made. PMID:24959622

  16. Design and Test of Passively Operated Heat Switches for 0.2 to 15 K

    NASA Technical Reports Server (NTRS)

    DiPirro, M. J.; Shirron, P. J.; Canavan, E. R.; Francis, J. J.; Tuttle, J. G.

    2003-01-01

    Heat switches have many uses in cryogenics, from regulating heat flow between refrigeration stages to thermally isolating components once they have cooled to low temperature. Among the techniques one can use for thermal switching, the gas-gap technique has the advantages of wide operating temperature range, high switching ratio, and no moving parts. The traditional gas-gap switch uses copper conductors separated by a small gap and an external getter. The switch is activated by heating and cooling the getter by moving gas into and out of the gap, turning the switch on and off. We have designed, built and tested heat switches that use an internal getter to passively turn off at temperatures between 0.2 and 15 K. The getter is thermally anchored to one side of the switch, and when that side of the switch cools through a transition region, gas adsorbs onto the getter and the switch turns off. The challenges are to make the transition region very narrow and tailorable to a wide range of applications, and to achieve high gas conductance when the switch is on. We have made switches using He-3, He-4, hydrogen, and neon gas, and have used charcoal and various metal substrates as getters. Switching ratios range from 1000 to over 10,000. Design and performance of these switches will be discussed in detail.

  17. Alternatives Generation and Analysis for Heat Removal from High Level Waste Tanks

    SciTech Connect

    WILLIS, W.L.

    2000-06-15

    This document addresses the preferred combination of design and operational configurations to provide heat removal from high-level waste tanks during Phase 1 waste feed delivery to prevent the waste temperature from exceeding tank safety requirement limits. An interim decision for the preferred method to remove the heat from the high-level waste tanks during waste feed delivery operations is presented herein.

  18. Results from evaporation tests to support the MWTF heat removal system design

    SciTech Connect

    Crea, B.A.

    1994-12-22

    An experimental tests program was conducted to measure the evaporative heat removal from the surface of a tank of simulated waste. The results contained in this report constitute definition design data for the latest heat removal function of the MWTF primary ventilation system.

  19. Grouping of light water reactors for evaluation of decay heat removal capability

    SciTech Connect

    Karol, R.; Fresco, A.; Perkins, K.R.

    1984-06-01

    This grouping report provides a compilation of decay heat removal systems (DHRS) data for operating commercial light water reactors. The reactors have been divided into 12 groups based on similarity of the DHRS and related systems as part of the NRC Task Action Plan on Shutdown Decay Heat Removal Requirements.

  20. Impact of the amount of working fluid in loop heat pipe to remove waste heat from electronic component

    NASA Astrophysics Data System (ADS)

    Smitka, Martin; Kolková, Z.; Nemec, Patrik; Malcho, M.

    2014-03-01

    One of the options on how to remove waste heat from electronic components is using loop heat pipe. The loop heat pipe (LHP) is a two-phase device with high effective thermal conductivity that utilizes change phase to transport heat. It was invented in Russia in the early 1980's. The main parts of LHP are an evaporator, a condenser, a compensation chamber and a vapor and liquid lines. Only the evaporator and part of the compensation chamber are equipped with a wick structure. Inside loop heat pipe is working fluid. As a working fluid can be used distilled water, acetone, ammonia, methanol etc. Amount of filling is important for the operation and performance of LHP. This work deals with the design of loop heat pipe and impact of filling ratio of working fluid to remove waste heat from insulated gate bipolar transistor (IGBT).

  1. Thermal control system. [removing waste heat from industrial process spacecraft

    NASA Technical Reports Server (NTRS)

    Hewitt, D. R. (Inventor)

    1983-01-01

    The temperature of an exothermic process plant carried aboard an Earth orbiting spacecraft is regulated using a number of curved radiator panels accurately positioned in a circular arrangement to form an open receptacle. A module containing the process is insertable into the receptacle. Heat exchangers having broad exterior surfaces extending axially above the circumference of the module fit within arcuate spacings between adjacent radiator panels. Banks of variable conductance heat pipes partially embedded within and thermally coupled to the radiator panels extend across the spacings and are thermally coupled to broad exterior surfaces of the heat exchangers by flanges. Temperature sensors monitor the temperature of process fluid flowing from the module through the heat exchanges. Thermal conduction between the heat exchangers and the radiator panels is regulated by heating a control fluid within the heat pipes to vary the effective thermal length of the heat pipes in inverse proportion to changes in the temperature of the process fluid.

  2. Indirect passive cooling system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1990-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  3. Passive cooling safety system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.; Hui, Marvin M.; Berglund, Robert C.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  4. THERMAL STUDY OF THE DIII-D MACHINE HEAT REMOVAL CAPACITY

    SciTech Connect

    YIP,H; ADERSON,P.M; HOLTROP,K.L; HARRISON,S

    2003-10-01

    OAK-B135 With each plasma shot, the DIII-D tokamak dissipates 0.5 to 1.0 GJ of energy. Plasma shots may occur as frequently as every ten minutes, and the energy is removed in the form of heat by a cooling water system. to remove heat from the machine, cooling water circulates through each major heat source. These sources include the power supplies, motor/generator, rf current drives, neutral beam power supplies, magnetic field coils, and vacuum vessel. The cooling water system consists of isolated primary and secondary cooling loops separated by intermediate heat exchangers. As future DIII-D plans include operation during summer months and longer pulse duration, the cooling system's overall heat removal capability and performance efficiency must be assessed. Temperature and flow data from around the DIII-D facility are collected by a programmable logic controller (PLC); the data are used to analyze the heat generating sources, the heat transfer rate to intermediate heat exchangers, and the ultimate heat rejection to the environment via the cooling towers. A comparison of the original DIII-D machine design versus the actual performance determines the margin of heat removal capacity. projections of the heat removal rate for various longer plasma shots are made. Improvements in design and/or operational procedure will be necessary to attain the desired pulse duration.

  5. Passive solar-heating retrofit of a maintenance facility: First-year performance

    NASA Astrophysics Data System (ADS)

    Jackson, D. R.; Callahan, J. M.

    1982-09-01

    A 12,000 sf maintenance facility in Connecticut was retrofitted with a 1,500 sf passive solar Trombe wall, 2 in. of foam roof insulation and a new control system that allows night/weekend temperature setback. A new separate boiler was installed to heat an office/locker wing of the facility. An energy-consumption monitoring system was installed and collected data for 11/2 years before the retrofit and one complete year after the retrofit. Actual energy consumption for the facility was very close to that predicted using simple analytic methods. After the solar wall was installed and other energy-conservation measures implemented the yearly oil consumption was reduced to 2744 gallons/year.

  6. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part 1; Method and Uncertainties

    NASA Technical Reports Server (NTRS)

    Olson, William S.; Kummerow, Christian D.; Yang, Song; Petty, Grant W.; Tao, Wei-Kuo; Bell, Thomas L.; Braun, Scott A.; Wang, Yansen; Lang, Stephen E.; Johnson, Daniel E.

    2004-01-01

    A revised Bayesian algorithm for estimating surface rain rate, convective rain proportion, and latent heating/drying profiles from satellite-borne passive microwave radiometer observations over ocean backgrounds is described. The algorithm searches a large database of cloud-radiative model simulations to find cloud profiles that are radiatively consistent with a given set of microwave radiance measurements. The properties of these radiatively consistent profiles are then composited to obtain best estimates of the observed properties. The revised algorithm is supported by an expanded and more physically consistent database of cloud-radiative model simulations. The algorithm also features a better quantification of the convective and non-convective contributions to total rainfall, a new geographic database, and an improved representation of background radiances in rain-free regions. Bias and random error estimates are derived from applications of the algorithm to synthetic radiance data, based upon a subset of cloud resolving model simulations, and from the Bayesian formulation itself. Synthetic rain rate and latent heating estimates exhibit a trend of high (low) bias for low (high) retrieved values. The Bayesian estimates of random error are propagated to represent errors at coarser time and space resolutions, based upon applications of the algorithm to TRMM Microwave Imager (TMI) data. Errors in instantaneous rain rate estimates at 0.5 deg resolution range from approximately 50% at 1 mm/h to 20% at 14 mm/h. These errors represent about 70-90% of the mean random deviation between collocated passive microwave and spaceborne radar rain rate estimates. The cumulative algorithm error in TMI estimates at monthly, 2.5 deg resolution is relatively small (less than 6% at 5 mm/day) compared to the random error due to infrequent satellite temporal sampling (8-35% at the same rain rate).

  7. Sustained Heating Experiments for the Investigation of the Boiling Heat Removal at the Upper Surface of Metallic Layer

    SciTech Connect

    Kyoung-Ho Kang; Rae-Joon Park; Sang-Baik Kim; Hee-Dong Kim

    2006-07-01

    Sustained heating experiments are in progress to investigate the boiling configurations and to quantify the heat removal rate at the upper surface of a metallic layer in case of late in-vessel coolant injection. Pure Zinc is used as the simulant of metallic layer and bottom heating via cartridge heater plate is adopted to simulate the heat transfer from the oxidic pool. The test section is rectangular shape having 0.3 m in width and 0.5 m in length. The scoping test was performed. In the scoping test, the height of melt pool is 10 cm and the temperature of the test section bottom was intended to be controlled for maintaining the uniform temperature of 500 deg. C. The scoping test results indicate that the melt pool effectively cooled down via boiling heat removal without energetic melt coolant interaction. The heat removal rate was calculated by 456.27 kW/m{sup 2} {approx} 516.3 kW/m{sup 2} which confirms the effective boiling heat removal in the scoping test. (authors)

  8. Heat treatment in 110 °C liquid water used for passivating silicon surfaces

    NASA Astrophysics Data System (ADS)

    Nakamura, Tomohiko; Motoki, Takayuki; Ubukata, Junya; Sameshima, Toshiyuki; Hasumi, Masahiko; Mizuno, Tomohisa

    2016-04-01

    The simple passivation method of heat treatment in liquid water is discussed. Photo-induced effective minority carrier lifetime τ eff increased to 3.3 × 10-3 s above 110 °C for 1 h for 17-Ωcm n-type crystalline silicon. Increase in τ eff was observed ranging from 3.5 × 10-4 to 3.7 × 10-3 s for n-type silicon with resistivity ranging from 2 to 17 Ωcm. τ eff maintained high values ranging from 1.5 × 10-4 to 1.4 × 10-3 s for 1270 h. The metal-insulator-semiconductor-type diodes were formed on the top surfaces of the n-type and p-type substrates by forming Al and Au metals on the 0.7-nm-thin passivated layers. Rectified and Fowler-Nordheim current characteristics were observed in the dark field because of the difference of the work function between Al and Au. High photo-induced current density of 31.1 mA/cm2 and photovoltaic effect were observed in case of light illumination of AM 1.5 at 100 mW/cm2 to the rear surface. The recombination velocity in the regions under the metal electrode in the MIS structure was determined by lateral diffusion of photo-induced carriers. They were 1000 and 11,000 cm/s under Al and Au, respectively, in the n-type Si substrate.

  9. Monitoring Organic Contaminant Fluxes Following Dam Removal Utilizing Passive Sampler Technology

    EPA Science Inventory

    Restoration of riverine habitats and their associated ecosystems is a growing priority for government agencies (e.g., USEPA, NOAA, USDA), as well as non-profit conservation organizations (e.g., American Rivers). Dam removal is a major component of many restoration projects credi...

  10. Scalability of the natural convection shutdown heat removal test facility (NSTF) data to VHTR/NGNP RCCS designs.

    SciTech Connect

    Vilim, R .B.; Feldman, E. E.; Nuclear Engineering Division

    2007-08-07

    Passive safety in the Very High Temperature Reactor (VHTR) is strongly dependent on the thermal performance of the Reactor Cavity Cooling System (RCCS). Scaled experiments performed in the Natural Shutdown Test Facility (NSTF) are to provide data for assessing and/or improving computer code models for RCCS phenomena. Design studies and safety analyses that are to support licensing of the VHTR will rely on these models to achieve a high degree of certainty in predicted design heat removal rate. To guide in the selection and development of an appropriate set of experiments a scaling analysis has been performed for the air-cooled RCCS option. The goals were to (1) determine the phenomena that dominate the behavior of the RCCS, (2) determine the general conditions that must be met so that these phenomena and their relative importance are preserved in the experiments, (3) identify constraints specific to the NSTF that potentially might prevent exact similitude, and (4) then to indicate how the experiments can be scaled to prevent distortions in the phenomena of interest. The phenomena identified as important to RCCS operation were also the subject of a recent PIRT study. That work and the present work collectively indicate that the main phenomena influencing RCCS heat removal capability are (1) radiation heat transport from the vessel to the air ducts, (2) the integral effects of momentum and heat transfer in the air duct, (3) buoyancy at the wall inside the air duct giving rise to mixed convection, and (4) multidimensional effects inside the air duct caused by non-uniform circumferential heat flux and non-circular geometry.

  11. Cerebrovascular responsiveness to steady-state changes in end-tidal CO2 during passive heat stress

    PubMed Central

    Low, David A.; Wingo, Jonathan E.; Keller, David M.; Davis, Scott L.; Zhang, Rong; Crandall, Craig G.

    2009-01-01

    This study tested the hypothesis that passive heat stress alters cerebrovascular responsiveness to steady-state changes in end-tidal CO2 (PetCO2). Nine healthy subjects (4 men and 5 women), each dressed in a water-perfused suit, underwent normoxic hypocapnic hyperventilation (decrease PetCO2 ~20 Torr) and normoxic hypercapnic (increase in PetCO2 ~9 Torr) challenges under normothermic and passive heat stress conditions. The slope of the relationship between calculated cerebrovascular conductance (CBVC; middle cerebral artery blood velocity/mean arterial blood pressure) and PetCO2 was used to evaluate cerebrovascular CO2 responsiveness. Passive heat stress increased core temperature (1.1 ± 0.2°C, P < 0.001) and reduced middle cerebral artery blood velocity by 8 ± 8 cm/s (P = 0.01), reduced CBVC by 0.09 ± 0.09 CBVC units (P = 0.02), and decreased PetCO2 by 3 ± 4 Torr (P = 0.07), while mean arterial blood pressure was well maintained (P = 0.36). The slope of the CBVC-PetCO2 relationship to the hypocapnic challenge was not different between normothermia and heat stress conditions (0.009 ± 0.006 vs. 0.009 ± 0.004 CBVC units/Torr, P = 0.63). Similarly, in response to the hypercapnic challenge, the slope of the CBVC-PetCO2 relationship was not different between normothermia and heat stress conditions (0.028 ± 0.020 vs. 0.023 ± 0.008 CBVC units/Torr, P = 0.31). These results indicate that cerebrovascular CO2 responsiveness, to the prescribed steady-state changes in PetCO2, is unchanged during passive heat stress. PMID:18218916

  12. Decay heat removal from a Particle Bed Reactor Nuclear Thermal Rocket engine

    SciTech Connect

    Gustafson, E.

    1993-06-01

    Nuclear Thermal Rockets used in propulsion systems for planetary exploration will generate significant amounts of heat following normal engine shutdown due to the buildup of and decay of radioactive fission products. The amount of energy that is generated as decay heat is approximately 2-5 percent of the energy released during nominal operation. Various schemes are possible for removing this heat, including using primary coolant (hydrogen) to cool the reactor. Depending on the amount of coolant required, this may result in a large weight penalty for the mission. This paper quantifies the amount of decay heat that must be removed from the engine, shows the resulting impact on the vehicle design for particular missions, and examines possible approaches for reducing the amount of coolant required for decay heat removal. The costs and benefits of these schemes will be shown for several different missions. The missions that will be considered include both manned Mars missions and unmanned planetary exploration missions. 6 refs.

  13. Heat-Assisted Machining for Material Removal Improvement

    NASA Astrophysics Data System (ADS)

    Mohd Hadzley, A. B.; Hafiz, S. Muhammad; Azahar, W.; Izamshah, R.; Mohd Shahir, K.; Abu, A.

    2015-09-01

    Heat assisted machining (HAM) is a process where an intense heat source is used to locally soften the workpiece material before machined by high speed cutting tool. In this paper, an HAM machine is developed by modification of small CNC machine with the addition of special jig to hold the heat sources in front of the machine spindle. Preliminary experiment to evaluate the capability of HAM machine to produce groove formation for slotting process was conducted. A block AISI D2 tool steel with100mm (width) × 100mm (length) × 20mm (height) size has been cut by plasma heating with different setting of arc current, feed rate and air pressure. Their effect has been analyzed based on distance of cut (DOC).Experimental results demonstrated the most significant factor that contributed to the DOC is arc current, followed by the feed rate and air pressure. HAM improves the slotting process of AISI D2 by increasing distance of cut due to initial cutting groove that formed during thermal melting and pressurized air from the heat source.

  14. Benchmark specifications for EBR-II shutdown heat removal tests

    SciTech Connect

    Sofu, T.; Briggs, L. L.

    2012-07-01

    Argonne National Laboratory (ANL) is hosting an IAEA-coordinated research project on benchmark analyses of sodium-cooled fast reactor passive safety tests performed at the Experimental Breeder Reactor-II (EBR-II). The benchmark project involves analysis of a protected and an unprotected loss of flow tests conducted during an extensive testing program within the framework of the U.S. Integral Fast Reactor program to demonstrate the inherently safety features of EBR-II as a pool-type, sodium-cooled fast reactor prototype. The project is intended to improve the participants' design and safety analysis capabilities for sodium-cooled fast reactors through validation and qualification of safety analysis codes and methods. This paper provides a description of the EBR-II tests included in the program, and outlines the benchmark specifications being prepared to support the IAEA-coordinated research project. (authors)

  15. Left ventricular systolic and diastolic function during tilt-table positioning and passive heat stress in humans.

    PubMed

    Nelson, Michael D; Altamirano-Diaz, Luis A; Petersen, Stewart R; DeLorey, Darren S; Stickland, Michael K; Thompson, Richard B; Haykowsky, Mark J

    2011-08-01

    The ventricular response to passive heat stress has predominantly been studied in the supine position. It is presently unclear how acute changes in venous return influence ventricular function during heat stress. To address this question, left ventricular (LV) systolic and diastolic function were studied in 17 healthy men (24.3 ± 4.0 yr; mean ± SD), using two-dimensional transthoracic echocardiography with Doppler ultrasound, during tilt-table positioning (supine, 30° head-up tilt, and 30° head-down tilt), under normothermic and passive heat stress (core temperature 0.8 ± 0.1°C above baseline) conditions. The supine heat stress LV volumetric and functional response was consistent with previous reports. Combining head-up tilt with heat stress reduced end-diastolic (25.2 ± 4.1%) and end-systolic (65.4 ± 10.5%) volume from baseline, whereas heart rate (37.7 ± 2.0%), ejection fraction (9.4 ± 2.4%), and LV elastance (37.7 ± 3.6%) increased, and stroke volume (-28.6 ± 9.4%) and early diastolic inflow (-17.5 ± 6.5%) and annular tissue (-35.6 ± 7.0%) velocities were reduced. Combining head-down tilt with heat stress restored end-diastolic volume, whereas LV elastance (16.8 ± 3.2%), ejection fraction (7.2 ± 2.1%), and systolic annular tissue velocities (22.4 ± 5.0%) remained elevated above baseline, and end-systolic volume was reduced (-15.3 ± 3.9%). Stroke volume and the early and late diastolic inflow and annular tissue velocities were unchanged from baseline. This investigation extends previous work by demonstrating increased LV systolic function with heat stress, under varied levels of venous return, and highlights the preload dependency of early diastolic function during passive heat stress. PMID:21536844

  16. Passive and Active Microwave Remote Sensing of Precipitation and Latent Heating Distributions in the Tropics from TRMM

    NASA Technical Reports Server (NTRS)

    Olson, William S.; Kummerow, Christian D.; Yang, Song; Haddad, Ziad S.; Tao, Wei-Kuo; Wang, Yansen; Lang, Stephen E.; Braun, Scott A.; Chiu, Christine; Wang, Jian-Jian

    2002-01-01

    Passive and active microwave remote sensing data are analyzed to identify signatures of precipitation and vertical motion in tropical convection. A database of cloud/radiative model simulations is used to quantify surface rain rates and latent heating profiles that are consistent with these signatures. At satellite footprint-scale (approximately 10 km), rain rate and latent heating estimates are subject to significant random errors, but by averaging the estimates in space and time, random errors are substantially reduced, Bias errors have been minimized by improving the microphysics in the supporting cloud/radiative model simulations, and by imposing a consistent definition of remotely-sensed and model-simulated convective/stratiform rain coverage. Remotely-sensed precipitation and latent heating distributions in the tropics are derived from Tropical Rainfall Measuring Mission (TRMM) and Special Sensor Microwave/ Imager (SSM/ I) sensor data. The prototype Version 6 TRMM passive microwave algorithm typically yields average heating profiles with maxima between 6 and 7 km altitude for organized mesoscale convective systems. Retrieved heating profiles for individual convective systems are compared to coincident estimates based upon a combination of dual-Doppler radar and rawinsonde data. Also, large-scale latent heating distributions are compared to estimates derived from a simpler technique that utilizes observations of surface rain rate and stratiform rain proportion to infer vertical heating structure. Results of these tests will be presented at the conference.

  17. Investigations on natural circulation in reactor models and shutdown heat removal systems for LMFBRs (liquid metal fast breeder reactors)

    SciTech Connect

    Hoffmann, H.; Weinberg, D.; Marten, K. ); Ieda, Yoshiaki )

    1989-11-01

    For sodium-cooled pool-type reactors, studies have been undertaken to remove the decay heat by natural convection alone, as in the case of failure of all power supplies. For this purpose, four immersion coolers (ICs), two each installed at a 180-deg circumferential position with respect to the others, are arranged within the reactor tank. They are connected with natural-drift air coolers through independent intermediate circuits. The primary sodium in the tank as well as the secondary sodium in the intermediate loop circulate by natural convection. The general functioning of this passive shutdown decay heat removal (DHR) system is demonstrated in 1:20 and 1:5 scale test models using water as a simulant fluid for sodium. The model design is based on the thermohydraulics similarity criteria. In the RAMONA three-dimensional 1:20 scale model, experiments were carried out to clarify the steady-state in-vessel thermohydraulics for different parameter combinations (core power, radial power distribution across the core, DHR by 2 or 4 ICs in operation, above-core structure geometry and position, different IC designs). For all mentioned parameters, temperatures and their fluctuations were measured and used to indicate isotherms and lines of identical temperature fluctuations. The flow patterns were observed visually. The experiments were recalculated by an updated version of the single-phase three-dimensional thermohydraulics code COMMIX.

  18. TRITIUM IN-BED ACCOUNTABILITY FOR A PASSIVELY COOLED, ELECTRICALLY HEATED HYDRIDE BED

    SciTech Connect

    Klein, J.; Foster, P.

    2011-01-21

    A PAssively Cooled, Electrically heated hydride (PACE) Bed has been deployed into tritium service in the Savannah River Site (SRS) Tritium Facilities. The bed design, absorption and desorption performance, and cold (non-radioactive) in-bed accountability (IBA) results have been reported previously. Six PACE Beds were fitted with instrumentation to perform the steady-state, flowing gas calorimetric inventory method. An IBA inventory calibration curve, flowing gas temperature rise ({Delta}T) versus simulated or actual tritium loading, was generated for each bed. Results for non-radioactive ('cold') tests using the internal electric heaters and tritium calibration results are presented. Changes in vacuum jacket pressure significantly impact measured IBA {Delta}T values. Higher jacket pressures produce lower IBA {Delta}T values which underestimate bed tritium inventories. The exhaust pressure of the IBA gas flow through the bed's U-tube has little influence on measured IBA {Delta}T values, but larger gas flows reduce the time to reach steady-state conditions and produce smaller tritium measurement uncertainties.

  19. Heat removal characteristics of a primary containment vessel external spray

    SciTech Connect

    Kataoka, Yoshiyuki; Fujii, Tadashi; Murase, Michio

    1996-10-01

    To evaluate the heat release characteristics of a primary containment vessel (PCV) external spray (one of the PCV cooling systems utilizing the steel PCV wall as the heat transfer medium), the thermal-hydraulic characteristics of the falling liquid film on the PCV surface have been investigated experimentally. Then, the performance of the PCV external spray cooling system was evaluated using the experimental findings. The following results were obtained: (1) Heat transfer coefficients of the falling liquid film under steady-state conditions were increased as the film flow rate per unit length of the liquid film width increased, and they agreed with Wilke`s correlation within about {+-}15%. (2) The PCV surface temperature, when preheated up to 150 C, which is the supposed PCV temperature under a severe accident, decreased below 100 C within a few seconds when the PCV external spray was initiated, and boiling on the PCV surface could not be maintained. (3) Heat transfer coefficients of the falling liquid film under transient conditions were higher initially due to the boiling effect; however, they decreased rapidly and approached those under steady-state conditions. (4) The PCV external spray for the conceptually designed PCV could suppress the PCV pressure below the design goal under a severe accident.

  20. Device for the removal of heat from waste water

    SciTech Connect

    Kalberer, F.

    1983-12-27

    Waste water is led into a container (1) through a inlet (4) at the top. A connection (20) between the inlet (4) and an outlet (21) having a check valve (22) comprises adjacent to the inlet (4) two inverted frusto-conical hollow bodies (24, 25) which are directly connected to each other. The connecting surface between the two hollow bodies (24, 25) is formed as a coarse screen (26). A round fine screen (30), which diverges downwardly, surrounds the hollow bodies (24,25). Heat exchangers (31) are located in the space between the fine screen (30) and the wall (2) of the container (1). An outlet (5) terminates at the bottom of the container and connects with a riser (6) and via a bend (7) with the sewerage conduit (8). Through the coarse screen (26) the waste water reaches the container, and the heat can reach the heat exchangers (31) through the fine screen (30), so that practically uncontaminated water is present at the heat exchangers, and the need for cleansing is substantially diminished.

  1. Design Report for the ½ Scale Air-Cooled RCCS Tests in the Natural convection Shutdown heat removal Test Facility (NSTF)

    SciTech Connect

    Lisowski, D. D.; Farmer, M. T.; Lomperski, S.; Kilsdonk, D. J.; Bremer, N.; Aeschlimann, R. W.

    2014-06-01

    The Natural convection Shutdown heat removal Test Facility (NSTF) is a large scale thermal hydraulics test facility that has been built at Argonne National Laboratory (ANL). The facility was constructed in order to carry out highly instrumented experiments that can be used to validate the performance of passive safety systems for advanced reactor designs. The facility has principally been designed for testing of Reactor Cavity Cooling System (RCCS) concepts that rely on natural convection cooling for either air or water-based systems. Standing 25-m in height, the facility is able to supply up to 220 kW at 21 kW/m2 to accurately simulate the heat fluxes at the walls of a reactor pressure vessel. A suite of nearly 400 data acquisition channels, including a sophisticated fiber optic system for high density temperature measurements, guides test operations and provides data to support scaling analysis and modeling efforts. Measurements of system mass flow rate, air and surface temperatures, heat flux, humidity, and pressure differentials, among others; are part of this total generated data set. The following report provides an introduction to the top level-objectives of the program related to passively safe decay heat removal, a detailed description of the engineering specifications, design features, and dimensions of the test facility at Argonne. Specifications of the sensors and their placement on the test facility will be provided, along with a complete channel listing of the data acquisition system.

  2. Aft Engine shop worker removes a heat shield on Columbia's main engines

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. -- Doug Buford, with the Aft Engine shop, works at removing a heat shield on Columbia, in the Orbiter Processing Facility. After small cracks were discovered on the LH2 Main Propulsion System (MPS) flow liners in two other orbiters, program managers decided to move forward with inspections on Columbia before clearing it for flight on STS-107. After removal of the heat shields, the three main engines will be removed. Inspections of the flow liners will follow. The July 19 launch of Columbia on STS-107 has been delayed a few weeks

  3. Aft Engine shop worker removes a heat shield on Columbia's main engines

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. - Doug Buford, with the Aft Engine shop, works at removing a heat shield on Columbia, in the Orbiter Processing Facility. After small cracks were discovered on the LH2 Main Propulsion System (MPS) flow liners in two other orbiters, program managers decided to move forward with inspections on Columbia before clearing it for flight on STS-107. After removal of the heat shields, the three main engines will be removed. Inspections of the flow liners will follow. The July 19 launch of Columbia on STS-107 has been delayed a few weeks

  4. Strategies for redundancy resolution of dual-arm systems with passive elements for tank waste removal

    SciTech Connect

    Dubey, R.; Love, L.J.

    1997-03-01

    The work described in this paper focuses on the coordination and control of two manipulators coupled by passive elements operating in a confined space. An example of one such system is the hardware used for the environmental response treatability study funded by the Department of Energy at Oak Ridge National Laboratory (ORNL). The motivation for this project is to establish the methodology necessary to extract large volumes of hazardous waste from underground storage facilities. The hardware used at ORNL consists of two long-reach manipulators. The first robot, the Modified Light Duty Utility Arm (MLDUA), is an 8-degree-of-freedom long-reach manipulator. The second arm, the Hose Management Arm (HMA), has two active degrees-of-freedom and provides hardware to break up and extract materials from the tank. Current strategies call for the MLDUA to grasp a combined sluicing end-effector attached, by a long flexible hose, to the HMA. The MLDUA will then move the combined system through the waste, extracting material. This paper describes many of the issues related to redundancy resolution and the coordinated control of these two robots. First, the authors provide a brief outline of the project and the existing hardware. This is followed by a description of existing redundancy resolution techniques and the impact redundancy has on the success of the project. Finally, preliminary simulation results show the effect cooperative control has on the level of forces generated between the dual-arm systems when coupled by an elastic exhaust hose. These results show a significant reduction in forces when both arms are active and have a combined manipulation strategy.

  5. Transient analysis of containment heat removal at Prairie Island with boiling in the fan coil tubes

    SciTech Connect

    Elicson, T.; Fraser, B.; Anderson, D.; Thomas, S.

    1996-12-31

    An analysis has been performed to determine the equilibrium cooling water flow rates and heat removal rates through the Prairie Island Nuclear Generating Plant containment fan coil units (CFCUs) under postulated accident conditions which leads to boiling in the CFCUs. Key components of the analysis include a detailed fan coil heat exchanger model, mass and energy conservation in the cooling tubes, two-phase flow effects on heat transfer and pressure drop, and pipe network modeling.

  6. The analysis of speed increase perspectives of nanostructuring burnishing with heat removal from the tool

    NASA Astrophysics Data System (ADS)

    Kuznetsov, V. P.; Skorobogatov, A. S.; Gorgots, V. G.; Yurovskikh, A. S.

    2016-04-01

    The work deals with investigation of opportunities of speed increase of nanostructuring burnishing due to heat removal from the contact area of severe plastic deformation using friction via the tool. The work has analyzed changes of the structure, thickness and quality of the modified layer, while increasing treatment speed of the tool without heat removal and with heat-cooling system. It is established that the cooling system of the tool indenter with a cooling capacity of 10 W allows for the two-times increase of the critical speed of burnishing, and when exceeding this speed, the deformable material does not turn into a nanostructuring state. It is shown that heat removal provides for a stable maintenance of the indenter temperature, an increase in thickness of the nanostructured layer up to 5 μm and roughness up to Ra = 150 nanometers at processing speed up to 0.17 m/s.

  7. A correction factor to f-chart predictions of active solar fraction in active-passive heating systems

    NASA Astrophysics Data System (ADS)

    Evans, B. L.; Beckman, W. A.; Duffie, J. A.; Mitchell, J. W.; Klein, S. A.

    1983-11-01

    The extent to which a passive system degrades the performance of an active solar space heating system was investigated, and a correction factor to account for these interactions was developed. The transient system simulation program TRNSYS is used to simulate the hour-by-hour performance of combined active-passive (hybrid) space heating systems in order to compare the active system performance with simplified design method predictions. The TRNSYS simulations were compared to results obtained using the simplified design calculations of the f-Chart method. Comparisons of TRNSYS and f-Chart were used to establish the accuracy of the f-Charts for active systems. A correlation was then developed to correct the monthly loads input into the f-Chart method to account for controller deadbands in both hybrid and active only buildings. A general correction factor was generated to be applied to the f-Chart method to produce more accurate and useful results for hybrid systems.

  8. Passive CO{sub 2} removal using a carbon fiber composite molecular sieve

    SciTech Connect

    Burchell, T.D.; Judkins, R.R.

    1995-12-01

    Manufacture and characterization of a carbon fiber composite molecular sieve (CFCMS), and its efficacy as a CO{sub 2} gas adsorbent are reported. The CFCMS consists of an isotropic pitch derived carbon fiber and a phenolic resin derived carbon binder. Activation (selective gasification) of the CFCMS creates microporosity in the carbon fibers, yielding high micropore volumes (>0.5 cm{sup 3}/g) and BET surface areas (>1000 m{sup 2}/g). Moreover, the CFCMS material is a rigid, strong, monolith with an open structure that allows the free-flow of fluids through the material. This combination of properties provides an adsorbent material that has several distinct advantages over granular adsorbents in gas separation systems such as pressure swing adsorption (PSA) units. The results of our initial evaluations of the CO{sub 2} adsorption capacity and kinetics of CFCMS are reported. The room temperature CO{sub 2} adsorption capacity of CFCMS is >120 mg of CO{sub 2} per g of CFCMS. A proposed project is described that targets the development, over a three-year period, of a demonstration separation system based on CFCMS for the removal of CO{sub 2} from a flue gas slip stream at a coal-fired power plant. The proposed program would be conducted jointly with industrial and utility partners.

  9. Jet pump-drive system for heat removal

    NASA Technical Reports Server (NTRS)

    French, James R. (Inventor)

    1987-01-01

    The invention does away with the necessity of moving parts such as a check valve in a nuclear reactor cooling system. Instead, a jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A main flow exists for a reactor coolant. A point of withdrawal is provided for a secondary flow. A TEMP, responsive to the heat from said coolant in the secondary flow path, automatically pumps said withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature where the heat is no longer a problem. At this lower temperature, the TEMP/jet pump combination ceases its circulation boosting operation. When the nuclear reactor is restarted and the coolant again exceeds the lower temperature setting, the TEMP/jet pump automatically resumes operation. The TEMP/jet pump combination is thus automatic, self-regulating and provides an emergency pumping system free of moving parts.

  10. Thermal-hydraulic investigations of the European Fast Reactor DHR (decay heat removal) system

    SciTech Connect

    Dueweke, M.; Friedel, G.; Friedrich, H.J. ); Azarian, G. ); Thomasson, R.K. )

    1989-11-01

    With the framework of the European Fast Reactor (EFR) program, a 2-yr conceptual design study was launched in spring 1988. One major area of investigation is the decay heat removal (DHR) following a reactor trip, when the steam plant heat sink is unavailable. Decay heat will be removed from the primary sodium by a safety-grade direct rector cooling system (DRCS), which should be as independent from the emergency power supply as possible. At present, the DRCS for EFR features three identical sodium loops, each with a 30-MW rating, operating in natural circulation under all circumstances. Each loop consists of a sodium/sodium heat-exchanging U-tube dip cooler and a sodium/air heat exchanger (AHX). The thermohydraulic behavior was studied with the one-dimensional system code DYANA and with the two-dimensional thermohydraulic code ATTICA.

  11. In-Bed Accountability Development for a Passively Cooled, Electrically Heated Hydride (PACE) Bed

    SciTech Connect

    Klein, J.E.

    2005-07-15

    A nominal 1500 STP-L PAssively Cooled, Electrically heated hydride (PACE) Bed has been developed for implementation into a new Savannah River Site tritium project. The 1.2 meter (four-foot) long process vessel contains on internal 'U-tube' for tritium In-Bed Accountability (IBA) measurements. IBA will be performed on six, 12.6 kg production metal hydride storage beds.IBA tests were done on a prototype bed using electric heaters to simulate the radiolytic decay of tritium. Tests had gas flows from 10 to 100 SLPM through the U-tube or 100 SLPM through the bed's vacuum jacket. IBA inventory measurement errors at the 95% confidence level were calculated using the correlation of IBA gas temperature rise, or (hydride) bed temperature rise above ambient temperature, versus simulated tritium inventory.Prototype bed IBA inventory errors at 100 SLPM were the largest for gas flows through the vacuum jacket: 15.2 grams for the bed temperature rise and 11.5 grams for the gas temperature rise. For a 100 SLPM U-tube flow, the inventory error was 2.5 grams using bed temperature rise and 1.6 grams using gas temperature rise. For 50 to 100 SLPM U-tube flows, the IBA gas temperature rise inventory errors were nominally one to two grams that increased above four grams for flows less than 50 SLPM. For 50 to 100 SLPM U-tube flows, the IBA bed temperature rise inventory errors were greater than the gas temperature rise errors, but similar errors were found for both methods at gas flows of 20, 30, and 40 SLPM.Electric heater IBA tests were done for six production hydride beds using a 45 SLPM U-tube gas flow. Of the duplicate runs performed on these beds, five of the six beds produced IBA inventory errors of approximately three grams: consistent with results obtained in the laboratory prototype tests.

  12. In-Bed Accountability Development for a Passively Cooled, Electrically Heated Hydride (PACE) Bed

    SciTech Connect

    KLEIN, JAMES

    2004-10-12

    A nominal 1500 STP-L PAssively Cooled, Electrically heated hydride (PACE) Bed has been developed for implementation into a new Savannah River Site tritium project. The 1.2 meter (four-foot) long process vessel contains an internal ''U-tube'' for tritium In-Bed Accountability (IBA) measurements. IBA will be performed on six, 12.6 kg production metal hydride storage beds. IBA tests were done on a prototype bed using electric heaters to simulate the radiolytic decay of tritium. Tests had gas flows from 10 to 100 SLPM through the U-tube or 100 SLPM through the bed's vacuum jacket. IBA inventory measurement errors at the 95 percent confidence level were calculated using the correlation of IBA gas temperature rise, or (hydride) bed temperature rise above ambient temperature, versus simulated tritium inventory. Prototype bed IBA inventory errors at 100 SLPM were the largest for gas flows through the vacuum jacket: 15.2 grams for the bed temperature rise and 11.5 grams for the gas temperature rise. For a 100 SLPM U-tube flow, the inventory error was 2.5 grams using bed temperature rise and 1.6 grams using gas temperature rise. For 50 to 100 SLPM U-tube flows, the IBA gas temperature rise inventory errors were nominally one to two grams that increased above four grams for flows less than 50 SLPM. For 50 to 100 SLPM U-tube flows, the IBA bed temperature rise inventory errors were greater than the gas temperature rise errors, but similar errors were found for both methods at gas flows of 20, 30, and 40 SLPM. Electric heater IBA tests were done for six production hydride beds using a 45 SLPM U-tube gas flow. Of the duplicate runs performed on these beds, five of the six beds produced IBA inventory errors of approximately three grams: consistent with results obtained in the laboratory prototype tests.

  13. Remote detection of heated ethanol plumes by airborne passive Fourier transform infrared spectrometry.

    PubMed

    Tarumi, Toshiyasu; Small, Gary W; Combs, Roger J; Kroutil, Robert T

    2003-11-01

    Methodology is developed for the automated detection of heated plumes of ethanol vapor with airborne passive Fourier transform infrared spectrometry. Positioned in a fixed-wing aircraft in a downward-looking mode, the spectrometer is used to detect ground sources of ethanol vapor from an altitude of 2000-3000 ft. Challenges to the use of this approach for the routine detection of chemical plumes include (1) the presence of a constantly changing background radiance as the aircraft flies, (2) the cost and complexity of collecting the data needed to train the classification algorithms used in implementing the plume detection, and (3) the need for rapid interferogram scans to minimize the ground area viewed per scan. To address these challenges, this work couples a novel ground-based data collection and training protocol with the use of signal processing and pattern recognition methods based on short sections of the interferogram data collected by the spectrometer. In the data collection, heated plumes of ethanol vapor are released from a portable emission stack and viewed by the spectrometer from ground level against a synthetic background designed to simulate a terrestrial radiance source. Classifiers trained with these data are subsequently tested with airborne data collected over a period of 2.5 years. Two classifier architectures are compared in this work: support vector machines (SVM) and piecewise linear discriminant analysis (PLDA). When applied to the airborne test data, the SVM classifiers perform best, failing to detect ethanol in only 8% of the cases in which it is present. False detections occur at a rate of less than 0.5%. The classifier performs well in spite of differences between the backgrounds associated with the ground-based and airborne data collections and the instrumental drift arising from the long time span of the data collection. Further improvements in classification performance are judged to require increased sophistication in the ground

  14. Multiple pollutant removal using the condensing heat exchanger. Task 2, Pilot scale IFGT testing

    SciTech Connect

    Jankura, B.J.

    1996-01-01

    The purpose of Task 2 (IFGT Pilot-Scale Tests at the B&W Alliance Research Center) is to evaluate the emission reduction performance of the Integrated flue Gas Treatment (IFGT) process for coal-fired applications. The IFGT system is a two-stage condensing heat exchanger that captures multiple pollutants - while recovering waste heat. The IFGT technology offers the potential of a addressing the emission of SO{sub 2} and particulate from electric utilities currently regulated under the Phase I and Phase II requirements defined in Title IV, and many of the air pollutants that will soon be regulated under Title III of the Clean Air Act. The performance data will be obtained at pilot-scale conditions similar to full-scale operating systems. The task 2 IFGT tests have been designed to investigate several aspects of IFGT process conditions at a broader range of variable than would be feasible at a larger scale facility. The performance parameters that will be investigated are as follows: SO{sub 2} removal; particulate removal; removal of mercury and other heavy metals; NO{sub x} removal; HF and HCl removal; NH{sub 3} removal; ammonia-sulfur compounds generation; and steam injection for particle removal. For all of the pollutant removal tests, removal efficiency will be based on measurements at the inlet and outlet of the IFGT facility. Heat recovery measurements will also be made during these tests to demonstrate the heat recovery provided by the IFGT technology. This report provides the Final Test Plan for the first coal tested in the Task 2 pilot-scale IFGT tests.

  15. Analysis of a heat recirculating cooler for fuel gas sulfur removal in solid oxide fuel cells

    NASA Astrophysics Data System (ADS)

    Richards, Geo. A.; Berry, David A.; Freed, Adam

    When using conventional fossil fuels, most fuel cell systems require sulfur removal as part of their fuel processing. A novel approach to enable conventional sulfur removal in high-temperature fuel processing is presented. Using established principles from heat-recirculating combustors, it is suggested that high-temperature syngas can be momentarily cooled to conditions that would permit conventional sulfur removal to be carried out at relatively low temperatures. The recirculated heat is then used to heat the gas back to conditions that are minimally less than the original temperature. A model for evaluating the performance of this concept is presented, and calculations suggest that relative to fuel cell applications, reasonable physical dimensions can be expected in actual applications. For high-pressure syngas (i.e., coal gasification), the physical dimensions will rise with the operating pressure.

  16. A PRA case study of extended long term decay heat removal for shutdown risk assessment

    SciTech Connect

    Roglans, J.; Ragland, W.A.; Hill, D.J.

    1992-12-01

    A Probabilistic Risk Assessment (PRA) of the Experimental Breeder Reactor II (EBR-II), a Department of Energy (DOE) Category A research reactor, has recently been completed at Argonne National Laboratory (ANL). The results of this PRA have shown that the decay heat removal system for EBR-II is extremely robust and reliable. In addition, the methodology used demonstrates how the actions of other systems not normally used for actions of other systems not normally used for decay heat removal can be used to expand the mission time of the decay heat removal system and further increase its reliability. The methodology may also be extended to account for the impact of non-safety systems in enhancing the reliability of other dedicated safety systems.

  17. A PRA case study of extended long term decay heat removal for shutdown risk assessment

    SciTech Connect

    Roglans, J.; Ragland, W.A.; Hill, D.J.

    1992-01-01

    A Probabilistic Risk Assessment (PRA) of the Experimental Breeder Reactor II (EBR-II), a Department of Energy (DOE) Category A research reactor, has recently been completed at Argonne National Laboratory (ANL). The results of this PRA have shown that the decay heat removal system for EBR-II is extremely robust and reliable. In addition, the methodology used demonstrates how the actions of other systems not normally used for actions of other systems not normally used for decay heat removal can be used to expand the mission time of the decay heat removal system and further increase its reliability. The methodology may also be extended to account for the impact of non-safety systems in enhancing the reliability of other dedicated safety systems.

  18. Jet pump-drive system for heat removal

    NASA Technical Reports Server (NTRS)

    French, J. R. (Inventor)

    1985-01-01

    A jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A TEMP, responsive to the heat from the coolant in the secondary flow path, automatically pumps the withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature. At this lower temperature, the TEMP/jet jump combination ceases its circulation boosting operation. The TEMP/jet pump combination is automatic, self-regulating and provides an emergency pumping system free of moving parts.

  19. Passive Fourier-transform infrared spectroscopy of chemical plumes: an algorithm for quantitative interpretation and real-time background removal

    NASA Astrophysics Data System (ADS)

    Polak, Mark L.; Hall, Jeffrey L.; Herr, Kenneth C.

    1995-08-01

    We present a ratioing algorithm for quantitative analysis of the passive Fourier-transform infrared spectrum of a chemical plume. We show that the transmission of a near-field plume is given by tau plume = (Lobsd - Lbb-plume)/(Lbkgd - Lbb-plume), where tau plume is the frequency-dependent transmission of the plume, L obsd is the spectral radiance of the scene that contains the plume, Lbkgd is the spectral radiance of the same scene without the plume, and Lbb-plume is the spectral radiance of a blackbody at the plume temperature. The algorithm simultaneously achieves background removal, elimination of the spectrometer internal signature, and quantification of the plume spectral transmission. It has applications to both real-time processing for plume visualization and quantitative measurements of plume column densities. The plume temperature (Lbb-plume ), which is not always precisely known, can have a profound effect on the quantitative interpretation of the algorithm and is discussed in detail. Finally, we provide an illustrative example of the use of the algorithm on a trichloroethylene and acetone plume.

  20. Organic Fluids and Passive Cooling in a Supercritical Rankine Cycle for Power Generation from Low Grade Heat Sources

    NASA Astrophysics Data System (ADS)

    Vidhi, Rachana

    Low grade heat sources have a large amount of thermal energy content. Due to low temperature, the conventional power generation technologies result in lower efficiency and hence cannot be used. In order to efficiently generate power, alternate methods need to be used. In this study, a supercritical organic Rankine cycle was used for heat source temperatures varying from 125°C to 200°C. Organic refrigerants with zero ozone depletion potential and their mixtures were selected as working fluid for this study while the cooling water temperature was changed from 10-25°C. Operating pressure of the cycle has been optimized for each fluid at every heat source temperature to obtain the highest thermal efficiency. Energy and exergy efficiencies of the thermodynamic cycle have been obtained as a function of heat source temperature. Efficiency of a thermodynamic cycle depends significantly on the sink temperature. At areas where water cooling is not available and ambient air temperature is high, efficient power generation from low grade heat sources may be a challenge. Use of passive cooling systems coupled with the condenser was studied, so that lower sink temperatures could be obtained. Underground tunnels, buried at a depth of few meters, were used as earth-air-heat-exchanger (EAHE) through which hot ambient air was passed. It was observed that the air temperature could be lowered by 5-10°C in the EAHE. Vertical pipes were used to lower the temperature of water by 5°C by passing it underground. Nocturnal cooling of stored water has been studied that can be used to cool the working fluid in the thermodynamic cycle. It was observed that the water temperature can be lowered by 10-20°C during the night when it is allowed to cool. The amount of water lost was calculated and was found to be approximately 0.1% over 10 days. The different passive cooling systems were studied separately and their effects on the efficiency of the thermodynamic cycle were investigated. They were

  1. Transient testing of the FFTF for decay-heat removal by natural convection

    SciTech Connect

    Beaver, T R; Johnson, H G; Stover, R L

    1982-06-01

    This paper reports on the series of transient tests performed in the FFTF as a major part of the pre-operations testing program. The structure of the transient test program was designed to verify the capability of the FFTF to safely remove decay heat by natural convection. The series culminated in a scram from full power to complete natural convection in the plant, simulating a loss of all electrical power. Test results and acceptance criteria related to the verification of safe decay heat removal are presented.

  2. Testing and heat treating of beryllium for machine-damage removal

    SciTech Connect

    Corle, R R; Leslie, W W; Brewer, A W

    1981-09-10

    The work performed in this program was designed to develop a sensitive test for detecting machine damage in beryllium and to evaluate heat treatment as a means of removing that damage. An impact-shear test was developed which proved to be very discriminating for the detection of machine damage in beryllium. The validity of this test was verified by high strain rate tensile tests. The data revealed that heat treating is equally as effective as chemical etching in removing machine damage from commercial grades of beryllium. The impact-shear test is significantly more discriminating than tensile testing at normal strain rates.

  3. Method and apparatus for removing heat from electronic devices using synthetic jets

    SciTech Connect

    Sharma, Rajdeep; Weaver, Stanton Earl; Seeley, Charles Erklin; Arik, Mehmet; Icoz, Tunc; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas

    2015-11-24

    An apparatus for removing heat comprises a heat sink having a cavity, and a synthetic jet stack comprising at least one synthetic jet mounted within the cavity. At least one rod and at least one engaging structure to provide a rigid positioning of the at least one synthetic jet with respect to the at least one rod. The synthetic jet comprises at least one orifice through which a fluid is ejected.

  4. Method and apparatus for removing heat from electronic devices using synthetic jets

    SciTech Connect

    Sharma, Rajdeep; Weaver, Jr., Stanton Earl; Seeley, Charles Erklin; Arik, Mehmet; Icoz, Tunc; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas

    2014-04-15

    An apparatus for removing heat comprises a heat sink having a cavity, and a synthetic jet stack comprising at least one synthetic jet mounted within the cavity. At least one rod and at least one engaging structure to provide a rigid positioning of the at least one synthetic jet with respect to the at least one rod. The synthetic jet comprises at least one orifice through which a fluid is ejected.

  5. An in vitro evaluation of passive ultrasonic agitation of different irrigants on smear layer removal after post space preparation: a scanning electron microscopic study.

    PubMed

    Srirekha, A; Rashmi, K; Hegde, Jayshree; Lekha, S; Rupali, K; Reshmi, George

    2013-09-01

    This study evaluated the removal of debris and smear layer after post space preparation using different irrigations and passive ultrasonic agitation. Sixty human premolars were decoronated and post space prepared after endodontic therapy. The samples were then randomly divided into three experimental groups (Groups A, B, C) and one control group (Group D) with fifteen samples in each group. Groups A and B samples were treated with 10 % citric acid and 17 % ethylenediamintetraacetic acid (EDTA), respectively and passive ultrasonic agitation was done, rinsed with sodium hypochlorite and finally flushed with saline. Group C samples were conditioned with 36 % phosphoric acid and then rinsed with saline. The control group was treated with 3 % sodium hypochlorite, passive ultrasonic agitation done and flushed with saline. The samples were sectioned and evaluated for debris and smear layer removal under scanning electron microscope. 10 % citric acid showed the best removal of smear layer when compared with 17 % EDTA and 36 % phosphoric acid, but was not statistically significant (p > 0.05). The difference in scoring for debris and smear layer removal in the coronal, middle and apical third of post space of experimental groups in comparison with control group was statistically significant (p < 0.001). PMID:24431741

  6. Influence of wick properties in a vertical LHP on remove waste heat from electronic equipment

    SciTech Connect

    Smitka, Martin E-mail: patrik.nemec@fstroj.uniza.sk Nemec, Patrik E-mail: patrik.nemec@fstroj.uniza.sk Malcho, Milan E-mail: patrik.nemec@fstroj.uniza.sk

    2014-08-06

    The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work is to develop porous wick of sintered nickel powder with different grain sizes. These porous wicks were used in LHP and there were performed a series of measurements to remove waste heat from the insulated gate bipolar transistor (IGBT)

  7. Modeling of heat transfer in a rotary kiln thermal desorder for removal of petroleum from soils

    SciTech Connect

    Chern, Hsien-Tsung; Krasnoperov, L.V.; Bozzelli, J.W.

    1996-10-01

    A continuous feed rotary kiln thermal desorber was designed and constructed to study the heat transfer in removal of petroleum hydrocarbons from contaminated soils. A mathematical model of heat transfer that correlates temperatures of gas, soil, and kiln wall will purge gas flow, soil feed rate, kiln rotation speed and soil residence time in the kiln desorber is developed. A fourth order Runge-Kutta method was used to numerically integrate the heat transfer process along the kiln length and to calculate the temperature profiles. Comparison of predicted and measured gas and soil temperature profile is presented.

  8. Influence of wick properties in a vertical LHP on remove waste heat from electronic equipment

    NASA Astrophysics Data System (ADS)

    Smitka, Martin; Nemec, Patrik; Malcho, Milan

    2014-08-01

    The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work is to develop porous wick of sintered nickel powder with different grain sizes. These porous wicks were used in LHP and there were performed a series of measurements to remove waste heat from the insulated gate bipolar transistor (IGBT).

  9. Multiple pollutant removal using the condensing heat exchanger. Task 3, Long term testing at the ECTC

    SciTech Connect

    Schulze, K.H.

    1996-01-01

    The objective of this task is to demonstrate long term operation of a condensing heat exchanger for coal-fired conditions. A small condensing heat exchanger will be installed at the Environmental Control Technology Center in Barker, New York. It will be installed downstream of the flue gas particulate removal system. The test will determine the amount of wear, if any, on the Teflon{trademark} covered internals of the heat exchanger. Visual inspection and measurements will be obtained for the Teflon{trademark} covered tubes during the test. The material wear study will conducted over a one year calendar period, and the CHX equipment will be operated to the fullest extent allowable.

  10. A&M. Radioactive parts security storage area, heat removal storage casks. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Radioactive parts security storage area, heat removal storage casks. Plan, section, and details. Ralph M. Parsons 1480-7 ANP/GE-3-720-S-1. Date: November 1958. Approved by INEEL Classification Office for public release. INEEL index no. 034-0720-60-693-107459 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  11. Lithium-metal infused trenches (LiMIT) for heat removal in fusion devices

    NASA Astrophysics Data System (ADS)

    Ruzic, D. N.; Xu, W.; Andruczyk, D.; Jaworski, M. A.

    2011-10-01

    Observation of liquid lithium flow in metal trenches has been made using a lithium-metal infused trench (LiMIT) tile and is reported here. The flow is self-pumping and uses thermoelectric magnetohydrodynamics to remove heated lithium and replenish it at a lower temperature. Flow velocities have been measured and compared with theoretical predictions.

  12. Moisture removal characteristics of thin layer rough rice under sequenced infrared radiation heating and cooling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Rice drying with infrared (IR) radiation has been investigated during recent years and showed promising potential with improved quality and energy efficiency. The objective of this study was to further investigate the moisture removal characteristics of thin layer rough rice heated by IR and cooled ...

  13. Metabolic Heat Regenerated Temperature Swing Adsorption for CO(sub 2) and Heat Removal/Rejection in a Martian PLSS

    NASA Technical Reports Server (NTRS)

    Iacomini, Christine; Powers, Aaron; Bowers, Chad; Straub-Lopez, Katie; Anderson, Grant; MacCallum, Taber; Paul, Heather

    2007-01-01

    Two of the fundamental problems facing the development of a Portable Life Support System (PLSS) for use on Mars, are (i) heat rejection (because traditional technologies use sublimation of water, which wastes a scarce resource and contaminates the premises), and (ii) rejection of CO2 in an environment with a ppCO2 of 0.4-0.9 kPa. Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed to address both these challenges. The technology utilizes an adsorbent that when cooled with liquid CO2 to near sublimation temperatures (195K) removes metabolically-produced CO2 in the vent loop. Once fully loaded, the adsorbent is then warmed externally by the vent loop (approx. 300K), rejecting the captured CO2 to Mars ambient. Two beds are used to effect a continuous cycle of CO2 removal/rejection as well as facilitate heat exchange out of the vent loop. Any cryogenic fluid can be used in the application; however, since CO2 is readily available at Mars and can be easily produced and stored on the Martian surface, the solution is rather elegant and less complicated when employing liquid CO2. As some metabolic heat will need to be rejected anyway, finding a practical use for metabolic heat is also an overall benefit to the PLSS. To investigate the feasibility of the technology, a series of experiments was conducted which lead to the selection and partial characterization of an appropriate adsorbent. The adsorbent NaX successfully removed CO2 from a simulated vent loop at the prescribed temperature swing anticipated during PLSS operating conditions on Mars using a cryogenic fluid. Thermal conductivity of the adsorbent was also measured to eventually aid in a demonstrator design of the technology. These results provide no show stoppers to the development of MTSA technology and allow its development to focus on other design challenges as listed in the conclusions.

  14. Demonstration of Passive Fuel Cell Thermal Management Technology

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian; Colozza, Anthony; Wynne, Robert; Miller, Michael; Meyer, Al; Smith, William

    2012-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates and integrated heat exchanger technology to collect the heat from the cooling plates (Ref. 1). The next step in the development of this passive thermal approach was the demonstration of the control of the heat removal process and the demonstration of the passive thermal control technology in actual fuel cell stacks. Tests were run with a simulated fuel cell stack passive thermal management system outfitted with passive cooling plates, an integrated heat exchanger and two types of cooling flow control valves. The tests were run to demonstrate the controllability of the passive thermal control approach. Finally, successful demonstrations of passive thermal control technology were conducted with fuel cell stacks from two fuel cell stack vendors.

  15. Efficiency of impurities removal in pyrophyllite using Fe/Si based heating susceptor

    NASA Astrophysics Data System (ADS)

    Kim, Bong-Ju; Cho, Kang Hee; Choi, Nag-Choul; Park, Cheon-Young

    2016-04-01

    The objective of this study was to efficiency of Fe removal in the pyrophyllite observed the mineralogical phase transformation and elevated temperature using Fe-Si based heating susceptor. The impurities in the pyrophyllite were observed hematite of oxide type and pyrite of sulfide type from photomicrograph and XRD analysis results. The impurities removal experiment were performed under microwave exposure condition(30min), heating susceptor type(Fe/Si) and two type(sulfide, oxide) pyrophyllite. The result showed that increasing of Al2O3 content in two type pyrophyllite with decreasing Fe2O3 and TiO2 content may be attributed to the mineral phase transform of impurities selected by microwave reaction. The microwave exposure for the pyrophyllite showed that the (1) pyrite and hematite phase was transformed pyrrhotite(sulfide type) and magnetite(oxide type), (2) The temperature was increased by Fe based heating susceptor: 932℃(sulfide type), 893℃(oxide type) and Si based heating susceptor: 615℃(sulfide type), 415℃(oxide type). As a result of the microwave Fe-Si based heating susceptor experiments, the Fe2O3 removal rates obtained were in the sulfide type case of 94.4%(Fe), 61.7%(Si) and oxide type case of 88.1%(Fe), 54.6%(Si). Acknowledgment : This subject is supported by Korea Ministry of Environment as "Advanced Technology Program for Environmental Industry"

  16. Passive cooling system for liquid metal cooled nuclear reactors with backup coolant flow path

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1993-01-01

    A liquid metal cooled nuclear fission reactor plant having a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during reactor shutdown, or heat produced during a mishap. This reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary system when rendered inoperable.

  17. Passive cooling system for top entry liquid metal cooled nuclear reactors

    DOEpatents

    Boardman, Charles E.; Hunsbedt, Anstein; Hui, Marvin M.

    1992-01-01

    A liquid metal cooled nuclear fission reactor plant having a top entry loop joined satellite assembly with a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during shutdown, or heat produced during a mishap. This satellite type reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary cooling system when rendered inoperative.

  18. Inorganic compounds for passive solar energy storage: Solid-state dehydration materials and high specific heat materials

    NASA Astrophysics Data System (ADS)

    Struble, L. J.; Brown, P. W.

    1986-04-01

    Two classes of hydrated inorganic salts have been studied to assess their potential as materials for passive solar energy storage. The materials are part of the quaternary system CaO-Al2O3-SO3-H2O and related chemical systems, and the two classes are typified by ettringite, a trisubstituted salt, and Friedel's salt, a monosubstituted salt. The trisubstituted salts were studied for their possible application in latent heat storage, utilizing a low-temperature dehydration reaction, and both classes were studies for their application in sensible heat storage. In order to assess their potential for energy storage, the salts have been synthesized, characterized by several analytical techniques, and thermal properties measured. The dehydration data of that the trisubstituted salts vary somewhat with chemical composition, with the temperature of the onset of dehydration ranging from 6(0)C to 33(0)C, and enthalpy changes on dehydration ranging from 60 to 200 cal/g. Heat capacity is less variable with composition; values for the trisubstituted phases are 30 cal/g/(0)C and for the monosubstituted phases between 0.23 and 0.28 cal/g/(0)C. Preliminary experiments indicate that the dehydration is reversible, and suggest that the materials might have additional potential as solar desiccant materials. These thermal data demonstrate the trisubstituted salts have potential as latent heat storage materials, and that both classes of salts have potential as sensible heat storage materials.

  19. Distinct Skeletal Muscle Gene Regulation from Active Contraction, Passive Vibration, and Whole Body Heat Stress in Humans

    PubMed Central

    Petrie, Michael A.; Kimball, Amy L.; McHenry, Colleen L.; Suneja, Manish; Yen, Chu-Ling; Sharma, Arpit; Shields, Richard K.

    2016-01-01

    Skeletal muscle exercise regulates several important metabolic genes in humans. We know little about the effects of environmental stress (heat) and mechanical stress (vibration) on skeletal muscle. Passive mechanical stress or systemic heat stress are often used in combination with many active exercise programs. We designed a method to deliver a vibration stress and systemic heat stress to compare the effects with active skeletal muscle contraction. Purpose: The purpose of this study is to examine whether active mechanical stress (muscle contraction), passive mechanical stress (vibration), or systemic whole body heat stress regulates key gene signatures associated with muscle metabolism, hypertrophy/atrophy, and inflammation/repair. Methods: Eleven subjects, six able-bodied and five with chronic spinal cord injury (SCI) participated in the study. The six able-bodied subjects sat in a heat stress chamber for 30 minutes. Five subjects with SCI received a single dose of limb-segment vibration or a dose of repetitive electrically induced muscle contractions. Three hours after the completion of each stress, we performed a muscle biopsy (vastus lateralis or soleus) to analyze mRNA gene expression. Results: We discovered repetitive active muscle contractions up regulated metabolic transcription factors NR4A3 (12.45 fold), PGC-1α (5.46 fold), and ABRA (5.98 fold); and repressed MSTN (0.56 fold). Heat stress repressed PGC-1α (0.74 fold change; p < 0.05); while vibration induced FOXK2 (2.36 fold change; p < 0.05). Vibration similarly caused a down regulation of MSTN (0.74 fold change; p < 0.05), but to a lesser extent than active muscle contraction. Vibration induced FOXK2 (p < 0.05) while heat stress repressed PGC-1α (0.74 fold) and ANKRD1 genes (0.51 fold; p < 0.05). Conclusion: These findings support a distinct gene regulation in response to heat stress, vibration, and muscle contractions. Understanding these responses may assist in developing regenerative

  20. The Effect of Passive Heat Stress and Exercise-Induced Dehydration on the Compensatory Reserve During Simulated Hemorrhage.

    PubMed

    Gagnon, Daniel; Schlader, Zachary J; Adams, Amy; Rivas, Eric; Mulligan, Jane; Grudic, Gregory Z; Convertino, Victor A; Howard, Jeffrey T; Crandall, Craig G

    2016-09-01

    Compensatory reserve represents the proportion of physiological responses engaged to compensate for reductions in central blood volume before the onset of decompensation. We hypothesized that compensatory reserve would be reduced by hyperthermia and exercise-induced dehydration, conditions often encountered on the battlefield. Twenty healthy males volunteered for two separate protocols during which they underwent lower-body negative pressure (LBNP) to hemodynamic decompensation (systolic blood pressure <80 mm Hg). During protocol #1, LBNP was performed following a passive increase in core temperature of ∼1.2°C (HT) or a normothermic time-control period (NT). During protocol #2, LBNP was performed following exercise during which: fluid losses were replaced (hydrated), fluid intake was restricted and exercise ended at the same increase in core temperature as hydrated (isothermic dehydrated), or fluid intake was restricted and exercise duration was the same as hydrated (time-match dehydrated). Compensatory reserve was estimated with the compensatory reserve index (CRI), a machine-learning algorithm that extracts features from continuous photoplethysmograph signals. Prior to LBNP, CRI was reduced by passive heating [NT: 0.87 (SD 0.09) vs. HT: 0.42 (SD 0.19) units, P <0.01] and exercise-induced dehydration [hydrated: 0.67 (SD 0.19) vs. isothermic dehydrated: 0.52 (SD 0.21) vs. time-match dehydrated: 0.47 (SD 0.25) units; P <0.01 vs. hydrated]. During subsequent LBNP, CRI decreased further and its rate of change was similar between conditions. CRI values at decompensation did not differ between conditions. These results suggest that passive heating and exercise-induced dehydration limit the body's physiological reserve to compensate for further reductions in central blood volume. PMID:27183303

  1. Resistively-Heated Microlith-based Adsorber for Carbon Dioxide and Trace Contaminant Removal

    NASA Technical Reports Server (NTRS)

    Roychoudhury, S.; Walsh, D.; Perry, J.

    2005-01-01

    An integrated sorber-based Trace Contaminant Control System (TCCS) and Carbon Dioxide Removal Assembly (CDRA) prototype was designed, fabricated and tested. It corresponds to a 7-person load. Performance over several adsorption/regeneration cycles was examined. Vacuum regenerations at effective time/temperature conditions, and estimated power requirements were experimentally verified for the combined CO2/trace contaminant removal prototype. The current paper details the design and performance of this prototype during initial testing at CO2 and trace contaminant concentrations in the existing CDRA, downstream of the drier. Additional long-term performance characterization is planned at NASA. Potential system design options permitting associated weight, volume savings and logistic benefits, especially as relevant for long-duration space flight, are reviewed. The technology consisted of a sorption bed with sorbent- coated metal meshes, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI). By contrast the current CO2 removal system on the International Space Station employs pellet beds. Preliminary bench scale performance data (without direct resistive heating) for simultaneous CO2 and trace contaminant removal was reviewed in SAE 2004-01-2442. In the prototype, the meshes were directly electrically heated for rapid response and accurate temperature control. This allowed regeneration via resistive heating with the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. A novel flow arrangement, for removing both CO2 and trace contaminants within the same bed, was demonstrated. Thus, the need for a separate trace contaminant unit was eliminated resulting in an opportunity for significant weight savings. Unlike the current disposable charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration.

  2. Multiple pollutant removal using the condensing heat exchanger: Phase 1 final report, October 1995--July 1997

    SciTech Connect

    Bailey, R.T.; Jankura, B.J.; Kudlac, G.A.

    1998-06-01

    The Integrated Flue Gas Treatment (IFGT) system is a new concept whereby a Teflon{reg_sign} covered condensing heat exchanger is adapted to remove certain flue gas constitutents, both particulate and gaseous, while recovering low level heat. Phase 1 includes two experimental tasks. One task dealt principally with the pollutant removal capabilities of the IFGT at a scale of about 1.2MW{sub t}. The other task studied the durability of the Teflon{reg_sign} covering to withstand the rigors of abrasive wear by fly ash emitted as a result of coal combustion. The pollutant removal characteristics of the IFGT system were measured over a wide range of operating conditions. The coals tested included high, medium and low-sulfur coals. The flue gas pollutants studied included ammonia, hydrogen chloride, hydrogen fluoride, particulate, sulfur dioxide, gas phase and particle phase mercury and gas phase and particle phase trace elements. The particulate removal efficiency and size distribution was investigated. These test results demonstrated that the IFGT system is an effective device for both acid gas absorption and fine particulate collection. The durability of the Teflon{reg_sign} covered heat exchanger tubes was studied on a pilot-scale single-stage condensing heat exchanger (CHX{reg_sign}). Data from the test indicate that virtually no decrease in Teflon{reg_sign} thickness was observed for the coating on the first two rows of heat exchanger tubes, even at high inlet particulate loadings. Evidence of wear was present only at the microscopic level, and even then was very minor in severity.

  3. A description of the active and passive sidewall-boundary-layer removal systems of the 0.3-meter transonic cryogenic tunnel

    NASA Technical Reports Server (NTRS)

    Johnson, C. B.; Murthy, A. V.; Ray, E. J.

    1986-01-01

    Results are presented for an operational checkout and shakedown of the active sidewall-boundary-layer removal system newly installed in the Langley 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT). Prior to the installation of this active removal system, the sidewall-boundary layer was removed passively by exhausting directly to the atmosphere (i.e., no reinjection). With the active removal system using the reinjection compressor, the removal capability is greatly expanded to cover the entire operating envelope of the 0.3-m TCT. Details of the active removal system are presented including the compressor reinjection circuit, the compressor pressure ratio/surge control, and the compressor recirculation loop. The control logic and features of the compressor surge control are explained. Initial tests covering critical operating conditions show mass flow removal rates of about 5 percent at lower Mach numbers can be obtained with the active system. Measured performance characteristics of the compressor are presented. As part of the validation of the active system, limited airfoil tests were made using the new system.

  4. Natural circulation decay heat removal from an SP-100, 550 kWe power system for a lunar outpost

    NASA Technical Reports Server (NTRS)

    El-Genk, Mohamed S.; Xue, Huimin

    1992-01-01

    This research investigated the decay heat removal from the SP-100 reactor core of a 550-kWe power system for a lunar outpost by natural circulation of lithium coolant. A transient model that simulates the decay heat removal loop (DHRL) of the power system was developed and used to assess the system's decay heat removal capability. The effects of the surface area of the decay heat rejection radiator, the dimensions of the decay heat exchanger (DHE) flow duct, the elevation of the DHE, and the diameter of the rise and down pipes in the DHRL on the decay heat removal capability were examined. Also, to determine the applicability of test results at earth gravity to actual system performance on the lunar surface, the effect of the gravity constant (1 g and 1/6 g) on the thermal behavior of the system after shutdown was investigated.

  5. Cyclic process for producing methane from carbon monoxide with heat removal

    DOEpatents

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  6. Cyclic process for producing methane in a tubular reactor with effective heat removal

    DOEpatents

    Frost, Albert C.; Yang, Chang-Lee

    1986-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  7. Construction and testing of a gas-loaded, passive-control, variable-conductance heat pipe

    NASA Technical Reports Server (NTRS)

    Depew, C. A.; Sauerbrey, W. J.; Benson, B. A.

    1973-01-01

    A methanol heat pipe using nitrogen gas for temperature control has been constructed and tested. The system was run over a power ratio of 15 (2 to 30 watts) with the heat source near ambient temperature and with the heat sink at a nominal value of 32 F. Control was obtained with a metal bellows gas reservoir which was actuated by an internal liquid-filled bellows. The liquid bellows was pressurized by expanding liquid methanol which was contained in an auxiliary reservoir in the evaporator heater block. It was demonstrated that the temperature variation of the heat source was reduced from 36 F for the heat pipe with no control to 7 F with the actuated bellows control.

  8. Origin of Surface-Driven Passive Liquid Flows.

    PubMed

    Yd, Sumith; Maroo, Shalabh C

    2016-08-30

    Passive liquid flow occurs in nature in the transport of water up tall trees and is desired for high-heat flux removal in thermal management devices. Typically, liquid-vapor surface tension is used to generate passive flows (e.g., capillary and Marangoni flows). In this work, we perform a fundamental molecular study on passive liquid flow driven by the solid-liquid surface tension force. Such surface tension values are first estimated by placing a liquid film over the surface and simulating various surface temperatures, followed by which simulations are performed by differential heating of the liquid film over the surface. Very strong passive liquid flows are obtained that lead to steady-state, continuous, and high-heat flux removal close to the maximum theoretical limit, as predicted by the kinetic theory of evaporation. Nondimensional empirical relations are developed for surface tension gradient, flow velocity, and evaporation rate. PMID:27483012

  9. Metabolic Heat Regenerated Temperature Swing Adsorption for CO2 and Heat Removal/Rejection in a Martian PLSS

    NASA Technical Reports Server (NTRS)

    Iacomini, Christine; Powers, Aaron; Bower, Chad; Straub-Lopez, Kathrine; Anderson, Grant; MacCallum, Taber; Paul, Heather L.

    2007-01-01

    Two of the fundamental problems facing the development of a Portable Life Support System (PLSS) for use on Mars, are (i) heat rejection (because traditional technologies use sublimation of water, which wastes a scarce resource and contaminates the premises), and (ii) rejection of carbon dioxide (CO2) in an environment with a CO2 partial pressure (ppCO2) of 0.4-0.9 kPa. Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed to address both these challenges. The technology utilizes an adsorbent that when cooled with liquid CO2 to near sublimation temperatures (195K) removes metabolically-produced CO2 in the ventilation loop. Once fully loaded, the adsorbent is then warmed externally by the ventilation loop (300K), rejecting the captured CO2 to Mars ambient. Two beds are used to provide a continuous cycle of CO2 removal/rejection as well as facilitate heat exchange out of the ventilation loop. Any cryogenic fluid can be used in the application; however, since CO2 is readily available on Mars and can be easily produced and stored on the Martian surface, the solution is rather elegant and less complicated when employing liquid CO2. As some metabolic heat will need to be rejected anyway, finding a practical use for metabolic heat is also an overall benefit to the PLSS. To investigate the feasibility of the technology, a series of experiments were conducted which lead to the selection and partial characterization of an appropriate adsorbent. The Molsiv Adsorbents 13X 8x12 (also known as NaX zeolite) successfully removed CO2 from a simulated ventilation loop at the prescribed temperature swing anticipated during PLSS operating conditions on Mars using a cryogenic fluid. Thermal conductivity of the adsorbent was also measured to eventually aid in a demonstrator design of the technology. These results provide no show stoppers to the development of MTSA technology and allow its development to focus on other design

  10. Comparative study of chemical and physical methods for distinguishing between passive and metabolically active mechanisms of water contaminant removal by biofilms.

    PubMed

    Adapa, L M; Azimi, Y; Singh, S; Porcelli, D; Thompson, I P

    2016-09-15

    In this study, physical and chemical approaches were employed to distinguish between passive and active mechanisms in biofilms removing contaminants in waste waters and their relative merits were assessed. Respiration, post-exposure recovery and scanning electron microscopic analysis demonstrated that both ultraviolet (UV) treatment (300 mJ/cm(2)) and sodium azide (10 mM) completely inhibited metabolic activity at 5 and 24 h exposure, respectively, whilst not damaging the integrity of the biofilms. Amongst the commonly used chemical inhibitors, only sodium azide showed complete inhibition after 24 h incubation with only about 10% (±4%) of biofilm carbon released into the bulk solution, compared to 33-41% (±8%) when exposed to 5 mM and 10 mM 2,4-dinitrophenol (DNP) and 69-80% (±5%) when exposed to 2% and 5% w/v formalin, respectively. Biofilm inhibition with UV and sodium azide was found to be equally effective at inhibiting biofilms for treatment of triethanolamine (TEA) and benzotriazole (BTA): the results confirming that the dominant removal mechanism was biodegradation. However, the rates of glucose removal by sodium azide-inhibited biofilms were similar to controls, suggesting that chemical inhibitors were not effective for distinguishing the removal mechanisms of simple sugars. Statistically similar amounts of metal were removed by biofilms treated with UV and sodium azide in zinc, copper and cadmium single-systems: the results indicated that the removal mechanism is predominantly a passive biosorption process. PMID:27314554

  11. Self-Driven Decay Heat Removal in a GCR Closed Brayton Cycle Power System

    SciTech Connect

    Wright, Steven A.; Lipinski, Ronald J.

    2006-07-01

    Closed Brayton Cycle (CBC) systems that are driven by Gas Cooled Reactors (GCR) are being evaluated for high-efficiency electricity generation. These systems were also selected by the Naval Reactor Prime Contractor team for use as space power systems. This paper describes the decay heat removal performance of these systems. A key question for such space or terrestrial based CBC systems is how to shut down the reactor while still removing the decay heat without using substantial amounts of auxiliary power. Tests in the Sandia Brayton Loop (SBL) show that the Brayton cycle is capable of operating on sensible heat for very long times ({approx} hour) after the reactor is shut down. This paper describes the measured and predicted results of generated electrical power produced as a function of time after the heat source had been turned off in the Sandia Brayton Loop. The measured results were obtained from an electrically heated closed Brayton cycle test loop (SBL) that Sandia fabricated and has operating within the laboratories. The predicted behavior is based on integrated dynamic system models that are capable of predicting both the transient and steady state behavior of nuclear heated or electrically heated Brayton cycle systems. The measured data was obtained by running the SBL and shutting off the electrical heater while adjusting the flow through the loop to keep the system operating at (or just above) its self-sustaining operating power level. During the test we were able to produce {approx}500 W of power for over 73 minutes after the heater power was turned off. Thus the Brayton loop was able to operate at self-sustaining conditions (or better) for over one hour. During this time the turbo-compressor was transporting the sensible heat in the heater, ducting, and recuperator to the waste heat rejection system for over an hour. For a reactor-driven system in space, this would give the shutdown decay power sufficient time to decay to levels where it could be

  12. Heat removal (wetting, heat transfer, T/H, secondary circuit, code validation etc.)

    SciTech Connect

    Dury, T.; Siman-Tov, M.

    1996-06-01

    This working group provided a comprehensive list of feasibility and uncertainty issues. Most of the issues seem to fall into the `needed but can be worked out` category. They feel these can be worked out as the project develops. A few issues can be considered critical or feasibility issues (that must be proven to be feasible). Those include: (1) Thermal shock and its mitigation (>1 MW); how to inject the He bubbles (if used) - back pressure into He lines - mercury traces in He lines; how to maintain proper bubble distribution and size (static and dynamic; if used); vibrations and fatigue (dynamic); possibility of cavitation from thermal shock. (2) Wetting and/or non-wetting of mercury on containment walls with or without gases and its effect on heat transfer (and materials). (3) Prediction capabilities in the CFD code; bubbles behavior in mercury (if used) - cross stream turbulence (ESS only) - wetting/non-wetting effects. (4) Cooling of beam `windows`; concentration of local heat deposition at center, especially if beam is of parabolic profile.

  13. Passive solar technology

    SciTech Connect

    Watson, D

    1981-04-01

    The present status of passive solar technology is summarized, including passive solar heating, cooling and daylighting. The key roles of the passive solar system designer and of innovation in the building industry are described. After definitions of passive design and a summary of passive design principles are given, performance and costs of passive solar technology are discussed. Passive energy design concepts or methods are then considered in the context of the overall process by which building decisions are made to achieve the integration of new techniques into conventional design. (LEW).

  14. System Analysis for Decay Heat Removal in Lead-Bismuth-Cooled Natural-Circulation Reactors

    SciTech Connect

    Sakai, Takaaki; Enuma, Yasuhiro; Iwasaki, Takashi

    2004-03-15

    Decay heat removal analyses for lead-bismuth-cooled natural-circulation reactors are described in this paper. A combined multidimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural-circulation reactors. For the preliminary study, transient analysis has been performed for a 300-MW(thermal) lead-bismuth-cooled reactor designed by Argonne National Laboratory. In addition, decay heat removal characteristics of a 400-MW(electric) lead-bismuth-cooled natural-circulation reactor designed by the Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. The primary reactor auxiliary cooling system (PRACS) is prepared for the JNC concept to get sufficient heat removal capacity. During 2000 s after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 deg. C because the buoyancy force in a primary circulation path is temporarily reduced. However, the natural circulation is recovered by the PRACS system, and the outlet temperature decreases successfully.

  15. System Analysis for Decay Heat Removal in Lead-Bismuth Cooled Natural Circulated Reactors

    SciTech Connect

    Takaaki Sakai; Yasuhiro Enuma; Takashi Iwasaki; Kazuhiro Ohyama

    2002-07-01

    Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heat removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 Centigrade, because the buoyancy force in a primary circulation path is temporary reduced. However, the natural circulation is recovered by the PRACS system and the out let temperature decreases successfully. (authors)

  16. The effect of passive heating and head cooling on perception, cardiovascular function and cognitive performance in the heat.

    PubMed

    Simmons, Shona E; Saxby, Brian K; McGlone, Francis P; Jones, David A

    2008-09-01

    The present study examined the effects of raising both skin temperature and core temperature, separately and in combination, on perceptions of heat-related fatigue (alertness, contentment, calmness and thermal comfort), cardiovascular function and on objective measures of cognitive performance (reaction time and accuracy). Ten (six males) subjects had cognitive performance assessed in three conditions; at low skin and low core temperature (LL), at high skin and low core temperature (HL) and at high skin and high core temperatures (HH). In one trial, subjects had their head and neck cooled (HC); the other trial was a control (CON). Raising skin temperature increased heart rate and decreased perception of thermal comfort (P < 0.05), whereas raising both skin and core temperature decreased perception of heat-related fatigue (P < 0.05) and increased cardiovascular strain (P < 0.05) resulting in decrements in cognitive performance shown by faster reaction times (P < 0.05) and a loss of accuracy (P < 0.05). At high skin and core temperatures, cooling the head and neck improved feelings of heat-related fatigue (P < 0.05) and cardiovascular strain (P < 0.05), but had no effect on cognitive performance. In conclusion, the results of this study suggest that feelings of heat-related fatigue and cardiovascular strain can be attributed to a combination of elevated skin and core body temperature, whereas decrements in cognitive performance can be attributed to an elevated core temperature. PMID:18214520

  17. CFD analysis for the applicability of the natural convection shutdown heat removal test facility (NSTF) for the simulation of the VHTR RCCS. Topical report.

    SciTech Connect

    Tzanos, C. P.; Nuclear Engineering Division

    2007-05-16

    The Very High Temperature gas cooled reactor (VHTR) is one of the GEN IV reactor concepts that have been proposed for thermochemical hydrogen production and other process-heat applications like coal gasification. The USDOE has selected the VHTR for further research and development, aiming to demonstrate emissions-free electricity and hydrogen production at a future time. One of the major safety advantages of the VHTR is the potential for passive decay heat removal by natural circulation of air in a Reactor Cavity Cooling System (RCCS). The air-side of the RCCS is very similar to the Reactor Vessel Auxiliary Cooling System (RVACS) that has been proposed for the PRISM reactor design. The design and safety analysis of the RVACS have been based on extensive analytical and experimental work performed at ANL. The Natural Convective Shutdown Heat Removal Test Facility (NSTF) at ANL that simulates at full scale the air-side of the RVACS was built to provide experimental support for the design and analysis of the PRISM RVACS system. The objective of this work is to demonstrate that the NSTF facility can be used to generate RCCS experimental data: to validate CFD and systems codes for the analysis of the RCCS; and to support the design and safety analysis of the RCCS.

  18. Volatility Diagrams for the Cr-O and Cr-Cl Systems: Application to Removal of Cr2O3-Rich Passive Films on Stainless Steel

    NASA Astrophysics Data System (ADS)

    Hsieh, Man-Ching; Ge, Yindong; Kahn, Harold; Michal, Gary M.; Ernst, Frank; Heuer, Arthur H.

    2012-10-01

    Effective diffusional surface treatments of stainless steels require that the naturally forming Cr2O3-rich passive layer be removed to "activate" or depassivate the surface. Volatility diagrams can be used to understand the possible etching reactions in the Cr-O and Cr-Cl systems and reveal five effective methods for removal of Cr2O3-based passivating films: (1) exposure to acetylene (C2H2) at 673 K (400 °C) and higher temperatures (providing sooting is avoided); (2) exposure to atomic hydrogen at 10 to 0.001 kPa (0.1 to 0.0001 bar) at 373 K to 673 K (100 °C to 400 °C); (3) exposure to wet oxygen above 573 K (300 °C), forming the volatile species CrO2(OH)2; (4) exposure to gaseous HCl at 100 kPa (1 bar) above 473 K (200 °C); and (5) oxidation of Cr2O3 to CrO3 using ozone or atomic oxygen, followed by exposure of CrO3 to gaseous H2 or HCl. The last process takes advantage of the fact that CrO3 is removed more effectively using gaseous H2 and HCl than is Cr2O3.

  19. Control of reactor coolant flow path during reactor decay heat removal

    DOEpatents

    Hunsbedt, Anstein N.

    1988-01-01

    An improved reactor vessel auxiliary cooling system for a sodium cooled nuclear reactor is disclosed. The sodium cooled nuclear reactor is of the type having a reactor vessel liner separating the reactor hot pool on the upstream side of an intermediate heat exchanger and the reactor cold pool on the downstream side of the intermediate heat exchanger. The improvement includes a flow path across the reactor vessel liner flow gap which dissipates core heat across the reactor vessel and containment vessel responsive to a casualty including the loss of normal heat removal paths and associated shutdown of the main coolant liquid sodium pumps. In normal operation, the reactor vessel cold pool is inlet to the suction side of coolant liquid sodium pumps, these pumps being of the electromagnetic variety. The pumps discharge through the core into the reactor hot pool and then through an intermediate heat exchanger where the heat generated in the reactor core is discharged. Upon outlet from the heat exchanger, the sodium is returned to the reactor cold pool. The improvement includes placing a jet pump across the reactor vessel liner flow gap, pumping a small flow of liquid sodium from the lower pressure cold pool into the hot pool. The jet pump has a small high pressure driving stream diverted from the high pressure side of the reactor pumps. During normal operation, the jet pumps supplement the normal reactor pressure differential from the lower pressure cold pool to the hot pool. Upon the occurrence of a casualty involving loss of coolant pump pressure, and immediate cooling circuit is established by the back flow of sodium through the jet pumps from the reactor vessel hot pool to the reactor vessel cold pool. The cooling circuit includes flow into the reactor vessel liner flow gap immediate the reactor vessel wall and containment vessel where optimum and immediate discharge of residual reactor heat occurs.

  20. Removal of silver nanoparticles using live and heat shock Aspergillus niger cultures.

    PubMed

    Gomaa, Ola M

    2014-06-01

    Silver nanoparticles (SNPs) are extensively used in many industrial and medical applications; however, the impact of their release in the environment is still considered an understudied field. In the present work, SNPs present in aqueous lab waste water (average size of 30 nm) were used to determine their impact on microflora if released in soil rhizosphere and sewage waste water. The results showed that 24 h incubation with different SNP concentrations resulted in a 2.6-fold decrease for soil rhizosphere microflora and 7.45-fold decrease for sewage waste water microflora, both at 24 ppm. Live and heat shock (50 and 70 °C) Aspergillus niger cultures were used to remove SNP waste, the results show 76.6, 81.74 and 90.8 % SNP removal, respectively after 3 h incubation. There was an increase in the log total bacterial count again after SNP removal by A. niger in the following order: live A. niger < 50 °C heat shock A. niger < 70 °C heat shock A. niger. The pH value decreased from 5.8 to 3.8 in the same order suggesting the production of an acid in the culture media. Scanning electron microscopy images showed agglomeration and/or complexation of SNP particles, in a micron size, in between the fungal mycelia, hence settling on and in between the mycelial network. The results suggest that silver was reduced again and agglomerated and/or chelated together in its oxidized form by an acid in A. niger media. More studies are recommended to determine the acid and the heat shock proteins to confirm the exact mode of action. PMID:24415500

  1. Thermal performance of plate-fin heat exchanger using passive techniques: vortex-generator and nanofluid

    NASA Astrophysics Data System (ADS)

    Khoshvaght-Aliabadi, Morteza

    2016-04-01

    This experimental study investigates the effects of vortex-generator (VG) and Cu/water nanofluid flow on performance of plate-fin heat exchangers. The Cu/water nanofluids are produced by using a one-step method, namely electro-exploded wire technique, with four nanoparticles weight fractions (i.e. 0.1, 0.2, 0.3, and 0.4 %). Required properties of nanofluids are systematically measured, and empirical correlations are developed. A highly precise test loop is fabricated to obtain accurate results of the heat transfer and pressure drop characteristics. Experiments are conducted for nanofluids flow inside the plain and VG channels. Based on the experimental results, utilizing the VG channel instead of the plain channel enhances the heat transfer rate, remarkably. Also, the results show that the VG channel is more effective than the nanofluid on the performance of plate-fin heat exchangers. It is observed that the combination of the two heat transfer enhancement techniques has a noticeably high thermal-hydraulic performance, about 1.67. Finally, correlations are developed to predict Nusselt number and friction factor of nanofluids flow inside the VG channel.

  2. An investigation of natural circulation decay heat removal from an SP-100 reactor system for a lunar outpost

    NASA Astrophysics Data System (ADS)

    El-Genk, Mohamed S.; Xue, Huimin

    1992-01-01

    A transient thermal-hydraulic model of the decay heat removal from a 550 kWe SP-100 power system for a lunar outpost has been developed and used to assess the coolability of the system by natural circulation after reactor shutdown. Results show that natural circulation of lithium coolant is sufficient to ensure coolability of the reactor core after shutdown. Further improvement of the decay heat removal capability of the system could be achieved by increasing the dimensions of the decay heat exchanger duct. A radiator area of 10-15 m2 would be sufficient to maintain the reactor core safely coolable by natural circulation after shutdown. Increasing the area of the decay heat rejection radiator or the diameter of the heat pipes in the guard vessel wall insignificantly affects the decay heat removal capability of the system.

  3. Multiple pollutant removal using the condensing heat exchanger: Phase 1 final report, November 1995--May 1997. Addendum 1: Task 2 topical report -- Pollutant removal tests

    SciTech Connect

    Bailey, R.T.; Jankura, B.J.

    1998-06-01

    Integrated Flue Gas Treatment (IFGT) uses two Condensing Heat Exchangers (CHXs{reg_sign}) in series to recover waste heat from the flue gas and remove a variety of pollutants from the flue gas. The Teflon{reg_sign}-covered internals of the condensing heat exchanger permit heat recovery at temperatures below the acid dew-point of the flue gas. The pollutant removal characteristics of the IFGT system were measured over a wide range of operating conditions in a pilot Integrated Flue Gas Treatment System rated at 1.2 MW{sub t} (4 million Btu/hr) using a wide range of coals. The coals tested included a high-sulfur coal, a medium-sulfur coal and a low-sulfur coal. The flue gas pollutants investigated included ammonia, hydrogen chloride, hydrogen fluoride, particulate, sulfur dioxide, gas phase and particle phase mercury and gas phase and particle phase trace elements. The particulate removal efficiency and size distribution was also investigated. Soda ash, lime and magnesium-lime scrubbing reagents were investigated. The test results show that the IFGT system can remove greater than 95% removal of acid gases with a liquid-to-gas ratio less than 1.34 l/m{sup 3} (10 gal/1,000 ft{sup 3}), and that lime reagents show promise as a substitute for soda ash. Particulate and ammonia gas removal was also very high. Ionic mercury removal averaged 80%, while elemental mercury removal was very low. Trace metals were found to be concentrated in the fine particulate with removal efficiencies in the range of 50% to 80%. The data measured in this task provides the basis for predictions of the performance of an IFGT system for both utility and industrial applications.

  4. Passive solar heating and natural cooling of an earth-integrated design

    SciTech Connect

    Barnes, P.R.; Shapira, H.B.

    1980-01-01

    The Joint Institute for Heavy Ion Research is being designed with innovative features that will greatly reduce its energy consumption for heating, cooling, and lighting. A reference design has been studied and the effects of extending the overhang during summer and fall, varying glazing area, employing RIB, and reducing internal heat by natural lighting have been considered. The use of RIB and the extendable overhang increases the optimum window glazing area and the solar heating fraction. A mass-storage wall which will likely be included in the final design has also been considered. A figure of merit for commercial buildings is the total annual energy consumption per unit area of floor space. A highly efficient office building in the Oak Ridge area typically uses 120 to 160 kWhr/m/sup 2/. The Joint Institute reference design with natural lighting, an annual average heat pump coefficient of performance (COP) equal to 1.8, RIB, and the extendable overhang uses 71 kWhr/m/sup 2/. This figure was determined from NBSLD simulations corrected for the saving from RIB. The internal heat energy from lighting and equipment used in the simulation was 1653 kWhrs/month (high natural lighting case) which is much lower than conventional office buildings. This value was adopted because only a portion of the building will be used as office space and efforts will be made to keep internal heat generation low. The mass-storage wall and ambient air cooling will reduce energy consumption still further. The combined savings of the innovative features in the Joint Institute building are expected to result in a very energy efficient design. The building will be instrumented to monitor its performance and the measured data will provide a means of evaluating the energy-saving features. The efficiency of the design will be experimentally verified over the next several years.

  5. A feasible way to remove the heat during adsorptive methane storage.

    PubMed

    Gütlein, Stefan; Burkard, Christoph; Zeilinger, Johannes; Niedermaier, Matthias; Klumpp, Michael; Kolb, Veronika; Jess, Andreas; Etzold, Bastian J M

    2015-01-01

    Methane originating from biogas or natural gas is an attractive and environmentally friendly alternative to gasoline. Adsorption is seen as promising storage technology, but the heat released limits fast filling of these systems. Here a lab scale adsorptive methane storage tank, capable to study the temperature increase during fast filling, was realized. A variation of the filling time from 1 h to 31 s, showed a decrease of the storage capacity of 14% and temperature increase of 39.6 °C. The experimental data could be described in good accordance with a finite element simulation solving the transient mass, energy, and impulse balance. The simulation was further used to extrapolate temperature development in real sized car tanks and for different heat pipe scenarios, resulting in temperature rises of approximately 110 °C. It could be clearly shown, that with heat conductivity as solei mechanism the heat cannot be removed in acceptable time. By adding an outlet to the tank a feed flow cooling with methane as heat carrier was realized. This setup was proofed in simulation and lab scale experiments to be a promising technique for fast adsorbent cooling and can be crucial to leverage the full potential of adsorptive methane gas storage. PMID:25485691

  6. Acetylsalicylic acid does not alter thermo-effector responses during mild whole-body passive heat stress in young men.

    PubMed

    Carter, Stephen J; Herron, Robert L; Akers, S Zeb; Bishop, Phillip A

    2015-06-01

    Acetylsalicylic acid (ASA), aspirin, exerts potent systemic effects that may interfere with normal thermo-effector responses. We investigated the influence of commonly ingested ASA doses on measures of skin blood flow (SkBF) and local sweat rate (SR) during whole-body, passive heat stress. Seven male participants completed counter-balanced trials to compare ASA treatments (single dose 325 mg or 4 consecutive days 81 mg (4-d 81 mg)) to control (no ASA). Laser-Doppler flowmetry provided an index of SkBF. A ventilated capsule measured local sweat rate via capacitance hygrometry. Mean body temperature ([Formula: see text]) was increased by 1 °C above baseline using a water-perfused suit. [Formula: see text] was similar at the onset of cutaneous vasodilation among trials. Cutaneous vascular conductance, expressed as a percentage change from baseline, was not different among trials. Additionally, [Formula: see text] at the onset of local SR and SR sensitivity did not differ among trials. While ASA has previously been shown to influence SkBF during heat stress, it is possible our cohort's relatively young age may have contributed to our dissimilar results. PMID:25697227

  7. Parametric Study to Characterize Low Activity Waste Tank Heat Removal Alternatives for Phase 1 Specification Development

    SciTech Connect

    GRENARD, C.E.

    2000-09-11

    Alternative for removing heat from Phase 1, low-activity waste feed double-shell tanks using the ventilation systems have been analyzed for Phase 1 waste feed delivery. The analysis was a parametric study using a model that predicted the waste temperatures for a range of primary and annulus ventilation system flow rates. The analysis was performed to determine the ventilation flow required to prevent the waste temperature from exceeding the Limiting Conditions for Operation limits during normal operation and the Safety Limits during off-normal events.

  8. A RELAP5/MOD3 simulation of loss of residual heat removal system after reactor

    SciTech Connect

    Tanrikut, A.; Heper, H.H.

    1995-12-31

    A computational investigation of the experiment concerning the loss of the residual heat removal system (RHRS) during reduced inventory operation was simulated using the RELAP5/ MOD3 thermal-hydraulic code. The experiment was conducted at the UMCP 2 x 4 integral test loop (University of Maryland) and consisted of two parts: loss of RHRS and loss of feedwater system. The objective of the work presented in this paper is to assess the capability of the RELAP5 code to capture the phenomena observed in the experiment during the boiler-condenser mode (BCM) and the loss of feedwater (LOFW) system transient.

  9. EFFECT OF SHORT-TERM HEAT ACCLIMATION TRAINING ON KINETICS OF LACTATE REMOVAL FOLLOWING MAXIMAL EXERCISE

    PubMed Central

    DiLeo, T.D.; Powell, J.B.; Kang, H-K.; Roberge, R.J.; Coca, A.; Kim, J-H.

    2016-01-01

    AIM Heat acclimation (HA) evokes numerous physiological adaptations, improves heat tolerance and has also been shown to enhance lactate (LA) responses during exercise, similar to that seen with endurance training. The purpose of this study was to examine whether HA improves the body’s ability to remove LA during recovery following maximal exercise. METHODS Ten healthy men completed two trials of maximal treadmill exercise (PRE- and POST-HA) separated by 5 days of HA. Each day of HA consisted of two 45 minute periods of cycling at ~50% VO2max separated by a 15min rest period in an environmental chamber (Tdb 45°C, RH 20%). In PRE-/POST-HA trials, venous blood was collected during 60 minutes of recovery to determine LA concentrations and removal kinetics (A2: amplitude and y2: velocity constant) using bi-exponential curve fitting. RESULTS Physiological adaptation to heat was significantly developed during HA, as evidenced by end-exercise Tre (DAY 1 vs. 5) (38.89±0.56 vs. 38.66±0.44 °C), Tsk (38.07±.51 vs. 37.66±.48 °C), HR (175.0±9.9 vs. 165.0±18.5 beats·min−1), and sweat rate (1.24 ±.26 vs. 1.47 ±.27 L·min−1) (p<.05). However, there was no significant difference in either LA concentrations (LA0min: 8.78±1.08 vs. 8.69±1.23; LApeak: 10.97±1.77 vs. 10.95±1.46; and La60min; 2.88±.82 vs. 2.96±.93 mmol·L−1) or removal kinetics (A2: −13.05±7.05 vs −15.59±7.90 mmol.L−1 and y2: .02±.01 vs .03±.01 min−1). CONCLUSION The present study concluded that, while effective in inducing thermo-physiological adaptations to heat stress, short-term HA does not improve the body’s ability to remove LA following maximal exercise. Therefore, athletes and workers seeking faster LA recovery from intense physical activity may not benefit from short-term HA. PMID:25286892

  10. Cooling system for removing metabolic heat from an hermetically sealed spacesuit

    NASA Technical Reports Server (NTRS)

    Webbon, B. W.; Vykukal, H. C.; Williams, B. A. (Inventor)

    1978-01-01

    An improved cooling and ventilating system is described for removing metabolic heat, waste gases and water vapor generated by a wearer of an hermetically sealed spacesuit. The cooling system was characterized by a body suit, having a first circuit for simultaneously establishing a cooling flow of water through the thorax and head sections of the body suit. Circulation patches were included mounted in the thorax section and head section of the body suit. A second circuit for discharing a flow of gas throughout the spacesuit and a disconnect unit for coupling the circuits with a life support system externally related to the spacesuit were provided.

  11. Fission product transport analysis in a loss of decay heat removal accident at Browns Ferry

    SciTech Connect

    Wichner, R.P.; Weber, C.F.; Hodge, S.A.; Beahm, E.C.; Wright, A.L.

    1984-01-01

    This paper summarizes an analysis of the movement of noble gases, iodine, and cesium fission products within the Mark-I containment BWR reactor system represented by Browns Ferry Unit 1 during a postulated accident sequence initiated by a loss of decay heat removal (DHR) capability following a scram. The event analysis showed that this accident could be brought under control by various means, but the sequence with no operator action ultimately leads to containment (drywell) failure followed by loss of water from the reactor vessel, core degradation due to overheating, and reactor vessel failure with attendant movement of core debris onto the drywell floor.

  12. Effects of obesity and mild hypohydration on local sweating and cutaneous vascular responses during passive heat stress in females.

    PubMed

    Moyen, Nicole E; Burchfield, Jenna M; Butts, Cory L; Glenn, Jordan M; Tucker, Matthew A; Treece, Keeley; Smith, Amber J; McDermott, Brendon P; Ganio, Matthew S

    2016-08-01

    The purpose of this study was to evaluate the effect of obesity and mild hypohydration on local sweating (LSR) and cutaneous vascular conductance (CVC) responses during passive heat stress in females. Thirteen obese (age, 24 ± 4 years; 45.4% ± 5.2% body fat) and 12 nonobese (age, 22 ± 2 years; 25.1% ± 3.9% body fat) females were passively heated (1.0 °C rectal temperature increase) while either euhydrated (EUHY) or mildly hypohydrated (HYPO; via fluid restriction). Chest and forearm LSR (ventilated capsule) and CVC (Laser Doppler flowmetry) onset, sensitivity, and plateau/steady state were recorded as mean body temperature increased (ΔTb). Participants began trials EUHY (urine specific gravity, Usg = 1.009 ± 0.006) or HYPO (Usg = 1.025 ± 0.004; p < 0.05), and remained EUHY or HYPO. Independent of obesity, HYPO decreased sweat sensitivity at the chest (HYPO = 0.79 ± 0.35, EUHY = 0.95 ± 0.39 Δmg·min(-1)·cm(-2)/°C ΔTb) and forearm (HYPO = 0.82 ± 0.39, EUHY = 1.06 ± 0.34 Δmg·min(-1)·cm(-2)/°C ΔTb); forearm LSR plateau was also decreased (HYPO = 0.66 ± 0.19, EUHY = 0.78 ± 0.23 mg·min(-1)·cm(-2); all p < 0.05). Overall, obese females had lower chest-sweat sensitivity (0.72 ± 0.35 vs. 1.01 ± 0.33 Δmg·min(-1)·cm(-2)/°C ΔTb) and plateau (0.55 ± 0.27 vs. 0.80 ± 0.25 mg·min(-1)·cm(-2); p < 0.05). While hypohydrated, obese females had a lower chest LSR (p < 0.05) versus nonobese females midway (0.45 ± 0.26 vs. 0.73 ± 0.23 mg·min(-1)·cm(-2)) and at the end (0.53 ± 0.27 vs. 0.81 ± 0.24 mg·min(-1)·cm(-2)) of heating. Furthermore, HYPO (relative to the EUHY trials) led to a greater decrease in CVC sensitivity in obese (-28 ± 27 Δ% maximal CVC/°C ΔTb) versus nonobese females (+9.2 ± 33 Δ% maximal CVC/°C ΔTb; p < 0.05). In conclusion, mild hypohydration impairs females' sweating responses during passive heat stress, and this effect is exacerbated when obese. PMID:27455036

  13. Removal of ammonium-nitrogen from groundwater using a fully passive permeable reactive barrier with oxygen-releasing compound and clinoptilolite.

    PubMed

    Huang, Guoxin; Liu, Fei; Yang, Yingzhao; Deng, Wei; Li, Shengpin; Huang, Yuanying; Kong, Xiangke

    2015-05-01

    A novel fully passive permeable reactive barrier (PRB) with oxygen-releasing compound (ORC) and clinoptilolite was proposed for the removal of ammonium-nitrogen from groundwater. The PRB involves a combination of oxygen release, biological nitrification, ion exchange, and bioregeneration. A pilot-scale performance comparison experiment was carried out employing three parallel columns to assess the proposed PRB. The results showed that the PRB achieved nearly complete [Formula: see text] depletion (>99%). [Formula: see text] of 5.23-10.88 mg/L was removed, and [Formula: see text] of <1.93 mg/L and [Formula: see text] of 2.03-19.67 mg/L were generated. Ion exchange and biological nitrification both contributed to [Formula: see text] removal, and the latter played a dominant role under the condition of sufficient oxygen. Biological nitrification favored a delay in sorption saturation and a release of exchange sites. The ORC could sufficiently, efficiently supply oxygen for approximately 120 pore volumes. The clinoptilolite ensured a robust [Formula: see text] removal in case of temporary insufficient biological activities. No external alkalinity sources had to be supplied and no inhibition of aerobic metabolism occurred. The ceramicite had a negligible effect on the biomass growth. Based on the research findings, a full-scale continuous wall PRB was installed in Shenyang, China in 2012. PMID:25700350

  14. Response of mice to continuous 5-day passive hyperthermia resembles human heat acclimation.

    PubMed

    Sareh, Houtan; Tulapurkar, Mohan E; Shah, Nirav G; Singh, Ishwar S; Hasday, Jeffrey D

    2011-05-01

    Chronic repeated exposure to hyperthermia in humans results in heat acclimation (HA), an adaptive process that is attained in humans by repeated exposure to hyperthermia and is characterized by improved heat elimination and increased exercise capacity, and acquired thermal tolerance (ATT), a cellular response characterized by increased baseline heat shock protein (HSP) expression and blunting of the acute increase in HSP expression stimulated by re-exposure to thermal stress. Epidemiologic studies in military personnel operating in hot environments and elite athletes suggest that repeated exposure to hyperthermia may also exert long-term health effects. Animal models demonstrate that coincident exposure to mild hyperthermia or prior exposure to severe hyperthermia can profoundly affect the course of experimental infection and injury, but these models do not represent HA. In this study, we demonstrate that CD-1 mice continuously exposed to mild hyperthermia (ambient temperature ~37°C causing ~2°C increase in core temperature) for 5 days and then exposed to a thermal stress (42°C ambient temperature for 40 min) exhibited some of the salient features of human HA, including (1) slower warming during thermal stress and more rapid cooling during recovery and (2) increased activity during thermal stress, as well as some of the features of ATT, including (1) increased baseline expression of HSP72 and HSP90 in lung, heart, spleen, liver, and brain; and (2) blunted incremental increase in HSP72 expression following acute thermal stress. This study suggests that continuous 5-day exposure of CD-1 mice to mild hyperthermia induces a state that resembles the physiologic and cellular responses of human HA. This model may be useful for analyzing the molecular mechanisms of HA and its consequences on host responsiveness to subsequent stresses. PMID:21080137

  15. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part 2; Evaluation of Estimates Using Independent Data

    NASA Technical Reports Server (NTRS)

    Yang, Song; Olson, William S.; Wang, Jian-Jian; Bell, Thomas L.; Smith, Eric A.; Kummerow, Christian D.

    2004-01-01

    Rainfall rate estimates from space-borne k&ents are generally accepted as reliable by a majority of the atmospheric science commu&y. One-of the Tropical Rainfall Measuring Mission (TRh4M) facility rain rate algorithms is based upon passive microwave observations fiom the TRMM Microwave Imager (TMI). Part I of this study describes improvements in the TMI algorithm that are required to introduce cloud latent heating and drying as additional algorithm products. Here, estimates of surface rain rate, convective proportion, and latent heating are evaluated using independent ground-based estimates and satellite products. Instantaneous, OP5resolution estimates of surface rain rate over ocean fiom the improved TMI algorithm are well correlated with independent radar estimates (r approx. 0.88 over the Tropics), but bias reduction is the most significant improvement over forerunning algorithms. The bias reduction is attributed to the greater breadth of cloud-resolving model simulations that support the improved algorithm, and the more consistent and specific convective/stratiform rain separation method utilized. The bias of monthly, 2.5 deg. -resolution estimates is similarly reduced, with comparable correlations to radar estimates. Although the amount of independent latent heating data are limited, TMI estimated latent heating profiles compare favorably with instantaneous estimates based upon dual-Doppler radar observations, and time series of surface rain rate and heating profiles are generally consistent with those derived from rawinsonde analyses. Still, some biases in profile shape are evident, and these may be resolved with: (a) additional contextual information brought to the estimation problem, and/or; (b) physically-consistent and representative databases supporting the algorithm. A model of the random error in instantaneous, 0.5 deg-resolution rain rate estimates appears to be consistent with the levels of error determined from TMI comparisons to collocated radar

  16. Heat removal from a stratified UO/sub 2/ - sodium-particle bed

    SciTech Connect

    Mitchell, G.W.; Lipinski, R.J.; Schwarz, M.L.

    1982-02-01

    The D6 Debris Bed Experiment is one in a series of Post Accident Heat Removal (PAHR) Experiments being conducted to investigate the coolability of debris beds which might exist as a result of a severe nuclear reactor accident. The D6 experiment is the first in the series to investigate the effects of particle size stratification, which would likely exist for many accident scenarios, on debris bed coolability. The D6 debris bed contained 4.87 kg of UO/sub 2/ particulate, which formed a bed 114 mm high and 102 mm in diameter. At low power, heat removal could be described by the conduction equation, with effective bed conductivity in agreement with the Kampf-Karsten relation to within ten percent. Single phase convection was not observed in the bed. The power required to achieve dryout ranged from 0.28 to 0.45 W/g for overlying bulk sodium temperatures which were from 315/sup 0/ to 485/sup 0/K below the saturation temperature. These powers are significantly below that which would be predicted by current models. Based on evaluation of the data, it appears that stratification suppresses convection, reduces the power required to achieve dryout, and suppresses the formation of vapor channels which would result in increased coolability.

  17. Shutdown decay heat removal analysis: Plant case studies and special issues: Summary report

    SciTech Connect

    Ericson, D.M. Jr.; Cramond, W.R.; Sanders, G.A.; Hatch, S.W.

    1989-04-01

    Shutdown Decay Heat Removal Requirements has been designated as Unresolved Safety Issue (USI) A-45. The overall objectives of the USI A-45 program were to evaluate the safety adequacy of decay heat removal (DHR) systems in existing light water reactor nuclear power plants and to assess the value and impact (benefit-cost) of alternative measures for improving the overall reliability of the DHR function. To provide the technical data required to meet these objectives a program was developed that examined the state of DHR system reliability in a sample of existing plants. This program identified potential vulnerabilities and identified and established the feasibility of potential measures to improve the reliability of the DHR function. A value/impact (V/I) analysis of the more promising of such measures was conducted and documented. This report summarizes those studies. In addition, because of the evolving nature of V/I analyses in support of regulation, a number of supporting studies related to appropriate procedures and measures for the V/I analyses were also conducted. These studies are also summarized herein. This report only summarizes findings of technical studies performed by Sandia National Laboratories as part of the program to resolve this issue. 46 refs., 7 figs., 124 tabs.

  18. Ultrafine particle removal by residential heating, ventilating, and air-conditioning filters.

    PubMed

    Stephens, B; Siegel, J A

    2013-12-01

    This work uses an in situ filter test method to measure the size-resolved removal efficiency of indoor-generated ultrafine particles (approximately 7-100 nm) for six new commercially available filters installed in a recirculating heating, ventilating, and air-conditioning (HVAC) system in an unoccupied test house. The fibrous HVAC filters were previously rated by the manufacturers according to ASHRAE Standard 52.2 and ranged from shallow (2.5 cm) fiberglass panel filters (MERV 4) to deep-bed (12.7 cm) electrostatically charged synthetic media filters (MERV 16). Measured removal efficiency ranged from 0 to 10% for most ultrafine particles (UFP) sizes with the lowest rated filters (MERV 4 and 6) to 60-80% for most UFP sizes with the highest rated filter (MERV 16). The deeper bed filters generally achieved higher removal efficiencies than the panel filters, while maintaining a low pressure drop and higher airflow rate in the operating HVAC system. Assuming constant efficiency, a modeling effort using these measured values for new filters and other inputs from real buildings shows that MERV 13-16 filters could reduce the indoor proportion of outdoor UFPs (in the absence of indoor sources) by as much as a factor of 2-3 in a typical single-family residence relative to the lowest efficiency filters, depending in part on particle size. PMID:23590456

  19. Passivation of nitinol wire for vascular implants--a demonstration of the benefits.

    PubMed

    O'Brien, B; Carroll, W M; Kelly, M J

    2002-04-01

    This study investigated a passivation process for polished nitinol wires and vascular stent components, after being given a typical shape setting heat treatment. Heat treated samples were passivated in a nitric acid solution and a series of corrosion tests, surface analysis and chemical analysis was performed. Potentiodynamic polarization tests demonstrated a significant increase in breakdown potential for passivated samples, compared to heat treated surfaces. Surface analysis indicated that the passivation reduces Ni and NiO content in the oxide and increases TiO2 content. Chemical analysis of passivation solutions suggests that the improvement in corrosion resistance is proportional to the quantity of nickel removed. Long term immersion tests demonstrate that nickel release from the surface of the material decreases with time and the quantity of nickel released is lower for passivated samples. The improved corrosion resistance is maintained after extended periods of immersion in saline solution. PMID:11950044

  20. Mitigation Measures Following a Loss-of-Residual-Heat-Removal Event During Shutdown

    SciTech Connect

    Seul, Kwang Won; Bang, Young Seok; Kim, Hho Jung

    2000-10-15

    The transient following a loss-of-residual-heat-removal event during shutdown was analyzed to determine the containment closure time (CCT) to prevent uncontrolled release of fission products and the gravity-injection path and rate (GIPR) for effective core cooling using the RELAP5/MOD3.2 code. The plant conditions of Yonggwang Units 3 and 4, a pressurized water reactor (PWR) of 2815-MW(thermal) power in Korea, were reviewed, and possible event sequences were identified. From the CCT analysis for the five cases of typical plant configurations, it was estimated for the earliest CCT to be 40 min after the event in a case with a large cold-leg opening and emptied steam generators (SGs). However, the case with water-filled SGs significantly delayed the CCT through the heat removal to the secondary side. From the GIPR analysis for the six possible gravity-injection paths from the refueling water storage tank (RWST), the case with the injection point and opening on the other leg side was estimated to be the most suitable path to avoid core boiling. In addition, from the sensitivity study, it was evaluated for the plant to be capable of providing the core cooling for the long-term transient if nominal RWST water is available. As a result, these analysis methods and results will provide useful information in understanding the plant behavior and preparing the mitigation measures after the event, especially for Combustion Engineering-type PWR plants. However, to directly apply the analysis results to the emergency procedure for such an event, additional case studies are needed for a wide range of operating conditions such as reactor coolant inventory, RWST water temperature, and core decay heat rate.

  1. Use of DRACS to Enhance HTGRs Passive Safety and Economy

    SciTech Connect

    Haihua Zhao; Hongbin Zhang; Ling Zou

    2011-06-01

    This paper discusses the use of DRACS to Enhance HTGRs Passive Safety and Economy. One of the important requirements for Gen. IV High Temperature Gas Cooled Reactors (HTGR) is passive safety. Currently all the HTGR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. [1] The decay heat first is transferred to core barrel by conduction and radiation, and then to reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. Similar concepts have been widely used in sodium cooled fast reactor (SFR) designs, advanced light water reactors like AP1000. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area. RVACS tends to be less expensive. However, it limits the largest achievable power level for modular HTGRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface). When the relative decay heat removal capability is reduced, the peak fuel temperature increases, even close to the design limit. Annual designs with internal reflector can mitigate this effect therefore further increase the power. Another way to increase power is to increase power density. However, it is also limited by the decay heat removal capability. Besides safety, HTGRs also need to be economical in order to compete with other reactor designs. The limit of decay heat removal capability set by using RVACS has affected the economy of HTGRs. Forsberg [2] pointed out other disadvantages of using RVACS such as conflicting functional requirements for the reactor vessel and scaling distortion for integral effect test of the system performance. A potential alternative solution is to use a volume based passive decay removal system, call Direct Reactor Auxiliary Cooling Systems (DRACS), to remove

  2. Hepatic heat shock protein 70 and plasma cortisol levels in rainbow trout after tagging with a passive integrated transponder

    USGS Publications Warehouse

    Feldhaus, J.W.; Heppell, S.A.; Mesa, M.G.; Li, H.

    2008-01-01

    This study examined the potentially stressful effects of tagging juvenile rainbow trout Oncorhynchus mykiss with passive integrated transponder (PIT) tags by measuring short-term (<120-h) changes in plasma concentrations of cortisol and hepatic heat shock protein 70 (hsp70). In a laboratory experiment, plasma cortisol levels were measured in fish before they were tagged (0 h) and at 2, 6, 24, and 120 h after being tagged. Hepatic hsp70 levels were measured at 0, 24, and 120 h. All results were compared with those for fish that were handled but not tagged. Plasma cortisol levels were significantly higher in both treatment groups (tagged and handled but not tagged) at 2 h than in the pretreatment groups (0 h). Plasma cortisol levels in the treatment groups returned to near pretreatment levels by 6 h. However, there was a significant difference in plasma cortisol levels between treatment groups at 6 h. There were no significant differences in hepatic hsp70 levels among the two treatment groups, and hepatic hsp70 levels did not change through time. Our results suggest that PIT tagging is a low-impact tagging procedure for juvenile salmonids. ?? Copyright by the American Fisheries Society 2008.

  3. Evaluation of contaminant removal of reverse osmosis and advanced oxidation in full-scale operation by combining passive sampling with chemical analysis and bioanalytical tools.

    PubMed

    Escher, Beate I; Lawrence, Michael; Macova, Miroslava; Mueller, Jochen F; Poussade, Yvan; Robillot, Cedric; Roux, Annalie; Gernjak, Wolfgang

    2011-06-15

    Advanced water treatment of secondary treated effluent requires stringent quality control to achieve a water quality suitable for augmenting drinking water supplies. The removal of micropollutants such as pesticides, industrial chemicals, endocrine disrupting chemicals (EDC), pharmaceuticals, and personal care products (PPCP) is paramount. As the concentrations of individual contaminants are typically low, frequent analytical screening is both laborious and costly. We propose and validate an approach for continuous monitoring by applying passive sampling with Empore disks in vessels that were designed to slow down the water flow, and thus uptake kinetics, and ensure that the uptake is only marginally dependent on the chemicals' physicochemical properties over a relatively narrow molecular size range. This design not only assured integrative sampling over 27 days for a broad range of chemicals but also permitted the use of a suite of bioanalytical tools as sum parameters, representative of mixtures of chemicals with a common mode of toxic action. Bioassays proved to be more sensitive than chemical analysis to assess the removal of organic micropollutants by reverse osmosis, followed by UV/H₂O₂ treatment, as many individual compounds fell below the quantification limit of chemical analysis, yet still contributed to the observed mixture toxicity. Nonetheless in several cases, the responses in the bioassays were also below their quantification limits and therefore only three bioassays were evaluated here, representing nonspecific toxicity and two specific end points for estrogenicity and photosynthesis inhibition. Chemical analytical techniques were able to quantify 32 pesticides, 62 PCPPs, and 12 EDCs in reverse osmosis concentrate. However, these chemicals could explain only 1% of the nonspecific toxicity in the Microtox assay in the reverse osmosis concentrate and 0.0025% in the treated water. Likewise only 1% of the estrogenic effect in the E-SCREEN could be

  4. Multiple pollutant removal using the condensing heat exchanger: Preliminary test plan for Task 2, Pilot scale IFGT testing

    SciTech Connect

    Jankura, B.J.

    1995-11-01

    The purpose of Task 2 (IFGT Pilot-Scale Tests at the B&W Alliance Research Center) is to evaluate the emission reduction performance of the Integrated Flue Gas Treatment (IFGT) process for coal-fired applications. The IFGT system is a two-stage condensing heat exchanger that captures multiple pollutants -- while recovering waste heat. The IFGT technology offers the potential of addressing the emission of S0{sub 2} and particulate from electric utilities currently regulated under the Phase 1 and Phase 2 requirements defined in Title IV, and many of the air pollutants that will soon be regulated under Title III of the Clean Air Act. The performance data will be obtained at pilot-scale conditions similar to full-scale operating systems. The Task 2 IFGT tests have been designed to investigate several aspects of IFGT process conditions at a broader range of variables than would be feasible at a larger scale facility. The data from these tests greatly expands the IFGT performance database for coals and is needed for the technology to progress from the component engineering phase to system integration and commercialization. The performance parameters that will be investigated are as follows: SO{sub 2} removal; particulate removal; removal of mercury and other heavy metals; NO{sub x} removal; HF and HCl removal; NH{sub 3} removal; ammonia-sulfur compounds generation; and steam injection for particle removal. For all of the pollutant removal tests, removal efficiency will be based on measurements at the inlet and outlet of the IFGT facility. Heat recovery measurements will also be made during these tests to demonstrate the heat recovery provided by the IFGT technology. This report provides a preliminary test plan for all of the Task 2 pilot-scale IFGT tests.

  5. Thermal-hydraulic processes involved in loss of residual heat removal during reduced inventory operation

    SciTech Connect

    Fletcher, C.D.; McHugh, P.R.; Naff, S.A.; Johnsen, G.W.

    1991-02-01

    This paper identifies the topics needed to understand pressurized water reactor response to an extended loss of residual heat removal event during refueling and maintenance outages. By identifying the possible plant conditions and cooling methods that would be used for each cooling mode, the controlling thermal-hydraulic processes and phenomena were identified. Controlling processes and phenomena include: gravity drain, core water boil-off, and reflux cooling processes. Important subcategories of the reflux cooling processes include: the initiation of reflux cooling from various plant conditions, the effects of air on reflux cooling, core level depression effects, issues regarding the steam generator secondaries, and the special case of boiler-condenser cooling with once-through steam generators. 25 refs., 6 figs., 1 tab.

  6. On the passivation mechanism of Fe3O4 nanoparticles during Cr(VI) removal from water: A XAFS study

    NASA Astrophysics Data System (ADS)

    Pinakidou, F.; Katsikini, M.; Simeonidis, K.; Kaprara, E.; Paloura, E. C.; Mitrakas, M.

    2016-01-01

    X-Ray Absorption Spectroscopies (XAFS) are employed in order to gather a thorough insight on the uptake mechanism of Cr(VI) by Fe3O4 nanoparticles under water treatment conditions. The XANES measurements identify that the reducing potential of Fe3O4 activates the precipitation of Cr(VI) in the form of insoluble and non-toxic Cr(III). However, electron donation from Fe(II) is responsible for its gradual consumption, resulting in the presence of a surface maghemite layer and the formation of structural vacancies. EXAFS analysis reveal that adsorption of Cr(III)-oxyanions occurs on sorption sites provided by the vacancies in the maghemite layer, where Cr(III) is involved in a bidentate binuclear (2E) geometry with Fe-octahedra while it also forms monodentate (1V) complexes with the Fe(III)O4 tetrahedra. The surface maghemitization along with the reduced Cr(III) adsorption into the vacancies, tracks the degree of Cr-reduction, since this surface structural modifications hinder Cr(VI) access to the Fe(II) ions of the magnetite nanoparticles. Thus, high surface coverage leads to the passivation of the reduction ability since physisorbed Cr(VI) is also detected through the formation of outer sphere complexes.

  7. Optimization of residual heat removal pump axial thrust and axial bearing

    SciTech Connect

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  8. Capillary-Pumped Passive Reactor Concept for Space Nuclear Power

    SciTech Connect

    Dr. Thomas F. Lin; Dr. Thomas G. Hughes; Christopher G. Miller

    2008-05-30

    To develop the passively-cooled space reactor concept using the capillary-induced lithium flow, since molten lithium possesses a very favorable surface tension characteristic. In space where the gravitational field is minimal, the gravity-assisted natural convection cooling is not effective nor an option for reactor heat removal, the capillary induced cooling becomes an attractive means of providing reactor cooling.

  9. Layer by layer removal of Au atoms from passivated Au(111) surfaces using the scanning tunneling microscope: Nanoscale ``paint stripping''

    NASA Astrophysics Data System (ADS)

    Keel, J. M.; Yin, J.; Guo, Q.; Palmer, R. E.

    2002-04-01

    Layer by layer removal of gold atoms from the (111) surface of gold has been performed using the scanning tunneling microscope. The process is made possible by a chemisorbed self-assembled monolayer (SAM) of dodecanethiol molecules on the surface, which gives rise to a reduced bonding strength between the top two layers of gold atoms. The gold atoms and associated adsorbed molecules are peeled off and displaced laterally by the STM tip, and the size of the modified area (down to ˜10×10 nm) is more or less determined by the scan size.

  10. Effectiveness of conventional syringe irrigation, vibringe, and passive ultrasonic irrigation performed with different irrigation regimes in removing triple antibiotic paste from simulated root canal irregularities

    PubMed Central

    Topçuoğlu, Hüseyin Sinan; Aktı, Ahmet; Topçuoğlu, Gamze; Düzgün, Salih; Ulusan, Özge; Akpek, Firdevs

    2016-01-01

    Background: This study evaluated the efficacy of a sonic device (Vibringe), passive ultrasonic irrigation (PUI), and conventional syringe irrigation (CSI) in the removal of triple antibiotic paste (TAP) from artificial standardized grooves in the apical and coronal thirds of a root canal. Materials and Methods: One-hundred eighteen root canals were prepared using the ProTaper system. The roots were split longitudinally, and a standardized groove was prepared in the apical and coronal parts of one segment. The grooves were filled with TAP, and the roots were reassembled. The roots were randomly divided into nine experimental groups and two control groups, according to the following irrigation methods: (1) CSI with sodium hypochlorite (NaOCl) + ethylenediaminetetraacetic acid (EDTA), (2) CSI/EDTA, (3) CSI/NaOCl, (4) PUI/NaOCl + EDTA, (5) PUI/EDTA, (6) PUI/NaOCl, (7) Vibringe/NaOCl + EDTA, (8) Vibringe/EDTA, and (9) Vibringe/NaOCl. The amount of remaining medicament was evaluated under a stereomicroscope. Results: In the apical third, Vibringe/NaOCl + EDTA and PUI/NaOCl + EDTA were superior to the other groups (P < 0.05); there was no significant difference between the other experimental groups (P > 0.05). In the coronal third, there was no significant difference between the experimental groups (P > 0.05). Conclusions: The use of the NaOCl/EDTA combination together with sonic or ultrasonic agitation improved the removal of TAP from the apical third. PMID:27563179

  11. Enhancing VHTR passive safety and economy with thermal radiation based direct reactor auxiliary cooling system

    SciTech Connect

    Zhao, H.; Zhang, H.; Zou, L.; Sun, X.

    2012-07-01

    One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The RVACS can be characterized as a surface-based decay heat removal system. It is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to the core volume) and decay heat removal capability (proportional to the vessel surface area). Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environmental side. For the reactor side, cooling pipes will be inserted into holes made in the outer or inner graphite reflector blocks. There will be gaps or annular regions formed between these cooling pipes and their corresponding surrounding graphite surfaces. Graphite has an excellent heat conduction property. By taking advantage of this feature, we can have a volume-based method to remove decay heat. The scalability can be achieved, if needed, by employing more rows of cooling pipes to accommodate higher decay heat rates. Since heat can easily conduct through the graphite regions among the holes made for the cooling pipes, those cooling pipes located further away from the active core region can still be very

  12. A concept of JAERI passive safety light water reactor system (JPSR)

    SciTech Connect

    Murao, Y.; Araya, F.; Iwamura, T.

    1995-09-01

    The Japan Atomic Energy Research Institute (JAERI) proposed a passive safety reactor system concept, JPSR, which was developed for reducing manpower in operation and maintenance and influence of human errors on reactor safety. In the concept the system was extremely simplified. The inherent matching nature of core generation and heat removal rate within a small volume change of the primary coolant is introduced by eliminating chemical shim and adopting in-vessel control rod drive mechanism units, a low power density core and once-through steam generators. In order to simplify the system, a large pressurizer, canned pumps, passive engineered-safety-features-system (residual heat removal system and coolant injection system) are adopted and the total system can be significantly simplified. The residual heat removal system is completely passively actuated in non-LOCAs and is also used for depressurization of the primary coolant system to actuate accumulators in small break LOCAs and reactor shutdown cooling system in normal operation. All of systems for nuclear steam supply system are built in the containment except for the air coolers as a the final heat sink of the passive residual heat removal system. Accordingly the reliability of the safety system and the normal operation system is improved, since most of residual heat removal system is always working and a heat sink for normal operation system is {open_quotes}safety class{close_quotes}. In the passive coolant injection system, depressurization of the primary cooling system by residual heat removal system initiates injection from accumulators designed for the MS-600 in medium pressure and initiates injection from the gravity driven coolant injection pool at low pressure. Analysis with RETRAN-02/MOD3 code demonstrated the capability of passive load-following, self-power-controllability, cooling and depressurization.

  13. Seasonal Acclimatization in Summer versus Winter to Changes in the Sweating Response during Passive Heating in Korean Young Adult Men

    PubMed Central

    Lee, Jeong-Beom; Min, Young-Ki; Yang, Hun-Mo

    2015-01-01

    We investigated the sweating response during passive heating (partial submersion up to the umbilical line in 42±0.5℃ water, 30 min) after summer and winter seasonal acclimatization (SA). Testing was performed in July during the summer, 2011 [summer-SA; temp, 25.6±1.8℃; relative humidity (RH), 82.1±8.2%] and in January during the winter, 2012 (winter-SA; temp, -2.7±2.9℃; RH, 65.0±13.1%) in Cheonan (126°52'N, 33.38'E), Republic of Korea. All experiments were carried out in an automated climatic chamber (temp, 25.0±0.5℃: RH, 60.0±3.0%). Fifteen healthy men (age, 23.4±2.5 years; height, 175.0±5.9 cm; weight, 65.3±6.1 kg) participated in the study. Local sweat onset time was delayed during winter-SA compared to that after summer-SA (p< 0.001). Local sweat volume, whole body sweat volume, and evaporative loss volume decreased significantly after winter-SA compared to those after summer-SA (p<0.001). Changes in basal metabolic rate increased significantly after winter-SA (p< 0.001), and tympanic temperature and mean body temperature were significantly lower after summer-SA (p<0.05). In conclusion, central sudomotor acitivity becomes sensitive to summer-SA and blunt to winter-SA in Rebubic of Korea. These results suggest that the body adjusts its temperature by economically controlling the sweating rate but does not lower the thermal dissipation rate through a more effective evaporation scheme after summer-SA than that after winter-SA. PMID:25605991

  14. Seasonal Acclimatization in Summer versus Winter to Changes in the Sweating Response during Passive Heating in Korean Young Adult Men.

    PubMed

    Lee, Jeong-Beom; Kim, Tae-Wook; Min, Young-Ki; Yang, Hun-Mo

    2015-01-01

    We investigated the sweating response during passive heating (partial submersion up to the umbilical line in 42±0.5℃ water, 30 min) after summer and winter seasonal acclimatization (SA). Testing was performed in July during the summer, 2011 [summer-SA; temp, 25.6±1.8℃; relative humidity (RH), 82.1±8.2%] and in January during the winter, 2012 (winter-SA; temp, -2.7±2.9℃; RH, 65.0±13.1%) in Cheonan (126°52'N, 33.38'E), Republic of Korea. All experiments were carried out in an automated climatic chamber (temp, 25.0±0.5℃: RH, 60.0±3.0%). Fifteen healthy men (age, 23.4±2.5 years; height, 175.0±5.9 cm; weight, 65.3±6.1 kg) participated in the study. Local sweat onset time was delayed during winter-SA compared to that after summer-SA (p< 0.001). Local sweat volume, whole body sweat volume, and evaporative loss volume decreased significantly after winter-SA compared to those after summer-SA (p<0.001). Changes in basal metabolic rate increased significantly after winter-SA (p< 0.001), and tympanic temperature and mean body temperature were significantly lower after summer-SA (p<0.05). In conclusion, central sudomotor acitivity becomes sensitive to summer-SA and blunt to winter-SA in Rebubic of Korea. These results suggest that the body adjusts its temperature by economically controlling the sweating rate but does not lower the thermal dissipation rate through a more effective evaporation scheme after summer-SA than that after winter-SA. PMID:25605991

  15. A Passive EMI Filter with Access to the Ungrounded Motor Neutral Line-Its Effect on Eliminating Leakage Current from the Inverter Heat Sink-

    NASA Astrophysics Data System (ADS)

    Doumoto, Takafumi; Akagi, Hirofumi

    This paper deals with a leakage current flowing out of the heat sink of a voltage-source PWM inverter. The heat-sink leakage current is caused by a steep change in the common-mode voltage produced by the inverter. It flows through parasitic capacitors between the heat sink and power semiconductor devices when no EMI filter is connected. Experimental results reveal that the heat-sink leakage current flows not into the supply side, but into the motor side. These understandings succeed in describing an equivalent common-mode circuit taking the parasitic capacitors into account. The authors have proposed a passive EMI filter that is unique in access to the ungrounded motor neutral line. It is discussed from this equivalent circuit that the passive EMI filter is effective in preventing the leakage current from flowing. Moreover, installation of another small-sized common-mode inductor at the ac side of the diode rectifier prevents the leakage current from flowing into the supply side. Experimental results obtained from a 200-V, 3.7-kW laboratory system confirm the effectiveness and viability of the EMI filter.

  16. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, C.W.

    1994-11-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature. 1 fig.

  17. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, Charles W.

    1994-01-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

  18. Shutdown Decay Heat Removal analysis of a Westinghouse 3-loop pressurized water reactor: Case study

    SciTech Connect

    Sanders, G.A.; Ericson, D.M. Jr.; Cramond, W.R.

    1987-03-01

    This is one of six case studies for USI A-45 Decay Heat Removal (DHR) Requirements. The purpose of this study is to identify any potential vulnerabilities in the DHR systems of a typical Westinghouse 3-loop PWR, to suggest possible modifications to improve the DHR capability, and to assess the value and impact of the most promising alternatives to the existing DHR systems. The systems analysis considered small LOCAs and transient internal initiating events, and seismic, fire, extreme wind, internal and external flood, and lightning external events. A full-scale systems analysis was performed with detailed fault trees and event trees including support system dependencies. The system analysis results were extrapolated into release categories using applicable past PRA phenomenological results and improved containment failure mode probabilities. Public consequences were estimated using site specific CRAC2 calculations. The Value-Impact (VI) analysis of possible alternatives considered both onsite and offsite impacts arriving at several risk measures such as averted population dose out to a 50-mile radius and dollars per person rem averted. Uncertainties in the VI analysis are discussed and the issues of feed and bleed and secondary blowdown are analyzed.

  19. Shutdown decay heat removal analysis of a Babcock and Wilcox pressurized water reactor: Case study

    SciTech Connect

    Cramond, W.R.; Ericson, D.M. Jr.; Sanders, G.A.

    1987-03-01

    This is one of six case studies for USI A-45 Decay Heat Removal (DHR) Requirements. The purpose of this study is to identify any potential vulnerabilities in the DHR systems of a typical Babcock and Wilcox PWR, to suggest possible modifications to improve the DHR capability, and to assess the value and impact of the most promising alternatives to the existing DHR systems. The systems analysis considered small LOCAs and transient internal initiating events, and seismic, fire, extreme wind, internal and external flood, and lightning external events. A full-scale systems analysis was performed with detailed fault trees and event trees including support system dependencies. The system analysis results were extrapolated into release categories using applicable past PRA phenomenological results and improved containment failure mode probabilities. Public consequences were estimated using site specific CRAC2 calculations. The Value-Impact (VI) analysis of possible alternatives considered both onsite and offsite impacts arriving at several risk measures such as averted population dose out to a 50-mile radius and dollars per person rem averted. Uncertainties in the VI analysis are discussed and the issues of feed and bleed and secondary blowdown are analyzed.

  20. Shutdown decay heat removal analysis of a Combustion Engineering 2-loop pressurized water reactor: Case study

    SciTech Connect

    Cramond, W.R.; Ericson, D.M. Jr.; Sanders, G.A.

    1987-08-01

    This is one of six case studies for USI A-45 Decay Heat Removal (DHR) Requirements. The purpose of this study is to identify any potential vulnerabilities in the DHR systems of a typical Combustion Engineering 2-loop PWR, to suggest possible modifications to improve the DHR capability, and to assess the value and impact of the most promising alternatives to the existing DHR systems. The systems analysis considered small LOCAs and transient internal initiating events, and seismic, fire, extreme wind, internal and external flood, and lightning external events. A full-scale systems analysis was performed with detailed fault trees and event trees including support system dependencies. The system analysis results were extrapolated into release categories using applicable past PRA phenomenological results and improved containment failure mode probabilities. Public consequences were estimated using site specific CRAC2 calculations. The Value-Impact (VI) analysis of possible alternatives considered both onsite and offsite impacts arriving at several risk measures such as averted population dose out to a 50-mile radius and dollars per person rem averted. Uncertainties in the VI analysis are discussed and the issues of feed and bleed and secondary blowdown are analyzed.

  1. Shutdown decay heat removal analysis of a Westinghouse 2-loop pressurized water reactor: Case study

    SciTech Connect

    Cramond, W.R.; Ericson, D.M. Jr.; Sanders, G.A.

    1987-03-01

    This is one of six case studies for USI A-45 Decay Heat Removal (DHR) Requirements. The purpose of this study is to identify any potential vulnerabilities in the DHR systems of a typical Westinghouse 2-loop PWR, to suggest possible modifications to improve the DHR capability, and to assess the value and impact of the most promising alternatives to the existing DHR systems. The systems analysis considered small LOCAs and transient internal initiating events, and seismic, fire, extreme wind, internal and external flood, and lightning external events. A full-scale systems analysis was performed with detailed fault trees and event trees including support system dependencies. The system analysis results were extrapolated into release categories using applicable past PRA phenomenological results and improved containment failure mode probabilities. Public consequences were estimated using site specific CRAC2 calculations. The Value-Impact (VI) analysis of possible alternatives considered both onsite and offsite impacts arriving at several risk measures such as averted population dose out to a 50-mile radius and dollars per person rem averted. Uncertainties in the VI analysis are discussed and the issues of feed and bleed and secondary blowdown are analyzed.

  2. Closeout of IE Bulletin 80-12: decay heat removal system operability

    SciTech Connect

    Foley, W.J.; Dean, R.S.; Hennick, A.

    1985-06-01

    On April 19, 1980, decay heat removal (DHR) capability was lost at Davis-Besse 1 for approximately two and one-half hours in a refueling mode. Typically for that mode, many systems and components were out of service for maintanance and testing or were deactivated to preclude inadvertent actuation. IE Bulletin 80-12 was issued May 9, 1980 for action by licensees of operating pressurized water reactors (PWRs); it was issued for information to nuclear power facilities other than operating PWRs. The intent of the bulletin ws to improve nuclear plant safety by reducing the likelihood of losing DHR capability in PWRs, especially when some DHR components are unavailable because of maintenance activities during refueling and cold shutdown modes of operation. A related NRR Generic Letter was issued June 11, 1980 to licensees of operating PWRs, requesting amendment of technical specifications to ensure long-term maintenance of DHR capability. Evaluation of utility responses and NRC/IE inspection reports indicates that the bulletin can be closed out per specific criteria for 33 (75%) of the 44 affected facilities.

  3. Simulation of loss-of-decay heat removal with MAAP 3. 0B

    SciTech Connect

    Plys, M.G.; Paik, C.Y.

    1989-01-01

    Loss-of-decay heat removal (DHR) during nonpower operation and its potential consequences have been of increasing concern to US pressurized water reactor (PWR) owners and regulators. Regulatory action prompted by the April 10, 1987, loss of DHR at Diablo Canyon Unit 2 cited 37 instances of loss of DHR events attributed to inadequate reactor coolant system (RCS) water level. In the Diablo Canyon event, 7 days after shutdown for its first refueling outage, boiling and pressurization of the primary system began after {approximately}1 h after loss of DHR, which was reestablished after another 20 min. This paper describes the modification and application of the Modular Accident Analysis Program (MAAP) version 3.0B (Ref. 3) for simulation of loss of DHR scenarios. MAAP 30.B, maintained by the Electric Power Research Institute and available to most US and many foreign utilities, is designed to perform coupled thermal-hydraulic and fission product calculations for severe-accident analysis. In this application, the capabilities of MAAP are extended to allow simulation of a shutdown plant state to calculate the time to core uncovery and fuel damage. Operator actions to mitigate or terminate the accident can be simulated, and timing of key events given by MAAP is useful for the evaluation of procedures.

  4. Fly ash carbon passivation

    DOEpatents

    La Count, Robert B; Baltrus, John P; Kern, Douglas G

    2013-05-14

    A thermal method to passivate the carbon and/or other components in fly ash significantly decreases adsorption. The passivated carbon remains in the fly ash. Heating the fly ash to about 500 and 800 degrees C. under inert gas conditions sharply decreases the amount of surfactant adsorbed by the fly ash recovered after thermal treatment despite the fact that the carbon content remains in the fly ash. Using oxygen and inert gas mixtures, the present invention shows that a thermal treatment to about 500 degrees C. also sharply decreases the surfactant adsorption of the recovered fly ash even though most of the carbon remains intact. Also, thermal treatment to about 800 degrees C. under these same oxidative conditions shows a sharp decrease in surfactant adsorption of the recovered fly ash due to the fact that the carbon has been removed. This experiment simulates the various "carbon burnout" methods and is not a claim in this method. The present invention provides a thermal method of deactivating high carbon fly ash toward adsorption of AEAs while retaining the fly ash carbon. The fly ash can be used, for example, as a partial Portland cement replacement in air-entrained concrete, in conductive and other concretes, and for other applications.

  5. Removal of As, Mn, Mo, Se, U, V and Zn from groundwater by zero-valent iron in a passive treatment cell: reaction progress modeling

    NASA Astrophysics Data System (ADS)

    Morrison, Stan J.; Metzler, Donald R.; Dwyer, Brian P.

    2002-05-01

    Three treatment cells were operated at a site near Durango, CO. One treatment cell operated for more than 3 years. The treatment cells were used for passive removal of contamination from groundwater at a uranium mill tailings repository site. Zero-valent iron [Fe(0)] that had been powdered, bound with aluminosilicate and molded into plates was used as a reactive material in one treatment cell. The others used granular Fe(0) and steel wool. The treatment cells significantly reduced concentrations of As, Mn, Mo, Se, U, V and Zn in groundwater that flowed through it. Zero-valent iron [Fe(0)], magnetite (Fe 3O 4), calcite (CaCO 3), goethite (FeOOH) and mixtures of contaminant-bearing phases were identified in the solid fraction of one treatment cell. A reaction progress approach was used to model chemical evolution of water chemistry as it reacted with the Fe(0). Precipitation of calcite, ferrous hydroxide [Fe(OH) 2] and ferrous sulfide (FeS) were used to simulate observed changes in major-ion aqueous chemistry. The amount of reaction progress differed for each treatment cell. Changes in contaminant concentrations were consistent with precipitation of reduced oxides (UO 2, V 2O 3), sulfides (As 2S 3, ZnS), iron minerals (FeSe 2, FeMoO 4) and carbonate (MnCO 3). Formation of a free gas phase and precipitation of minerals contributed to loss of hydraulic conductivity in one treatment cell.

  6. GaN as an interfacial passivation layer: tuning band offset and removing fermi level pinning for III-V MOS devices.

    PubMed

    Zhang, Zhaofu; Cao, Ruyue; Wang, Changhong; Li, Hao-Bo; Dong, Hong; Wang, Wei-Hua; Lu, Feng; Cheng, Yahui; Xie, Xinjian; Liu, Hui; Cho, Kyeongjae; Wallace, Robert; Wang, Weichao

    2015-03-11

    The use of an interfacial passivation layer is one important strategy for achieving a high quality interface between high-k and III-V materials integrated into high-mobility metal-oxide-semiconductor field-effect transistor (MOSFET) devices. Here, we propose gallium nitride (GaN) as the interfacial layer between III-V materials and hafnium oxide (HfO2). Utilizing first-principles calculations, we explore the structural and electronic properties of the GaN/HfO2 interface with respect to the interfacial oxygen contents. In the O-rich condition, an O8 interface (eight oxygen atoms at the interface, corresponding to 100% oxygen concentration) displays the most stability. By reducing the interfacial O concentration from 100 to 25%, we find that the interface formation energy increases; when sublayer oxygen vacancies exist, the interface becomes even less stable compared with O8. The band offset is also observed to be highly dependent on the interfacial oxygen concentration. Further analysis of the electronic structure shows that no interface states are present at the O8 interface. These findings indicate that the O8 interface serves as a promising candidate for high quality III-V MOS devices. Moreover, interfacial states are present when such interfacial oxygen is partially removed. The interface states, leading to Fermi level pinning, originate from unsaturated interfacial Ga atoms. PMID:25639492

  7. A Passive Heat Maintenance Strategy Implemented during a Simulated Half-Time Improves Lower Body Power Output and Repeated Sprint Ability in Professional Rugby Union Players

    PubMed Central

    Russell, Mark; West, Daniel J.; Briggs, Marc A.; Bracken, Richard M.; Cook, Christian J.; Giroud, Thibault; Gill, Nicholas; Kilduff, Liam P.

    2015-01-01

    Reduced physical performance has been observed following the half-time period in team sports players, likely due to a decrease in muscle temperature during this period. We examined the effects of a passive heat maintenance strategy employed between successive exercise bouts on core temperature (Tcore) and subsequent exercise performance. Eighteen professional Rugby Union players completed this randomised and counter-balanced study. After a standardised warm-up (WU) and 15 min of rest, players completed a repeated sprint test (RSSA 1) and countermovement jumps (CMJ). Thereafter, in normal training attire (Control) or a survival jacket (Passive), players rested for a further 15 min (simulating a typical half-time) before performing a second RSSA (RSSA 2) and CMJ’s. Measurements of Tcore were taken at baseline, post-WU, pre-RSSA 1, post-RSSA 1 and pre-RSSA 2. Peak power output (PPO) and repeated sprint ability was assessed before and after the simulated half-time. Similar Tcore responses were observed between conditions at baseline (Control: 37.06±0.05°C; Passive: 37.03±0.05°C) and for all other Tcore measurements taken before half-time. After the simulated half-time, the decline in Tcore was lower (-0.74±0.08% vs. -1.54±0.06%, p<0.001) and PPO was higher (5610±105 W vs. 5440±105 W, p<0.001) in the Passive versus Control condition. The decline in PPO over half-time was related to the decline in Tcore (r = 0.632, p = 0.005). In RSSA 2, best, mean and total sprint times were 1.39±0.17% (p<0.001), 0.55±0.06% (p<0.001) and 0.55±0.06% (p<0.001) faster for Passive versus Control. Passive heat maintenance reduced declines in Tcore that were observed during a simulated half-time period and improved subsequent PPO and repeated sprint ability in professional Rugby Union players. PMID:25785393

  8. A passive heat maintenance strategy implemented during a simulated half-time improves lower body power output and repeated sprint ability in professional Rugby Union players.

    PubMed

    Russell, Mark; West, Daniel J; Briggs, Marc A; Bracken, Richard M; Cook, Christian J; Giroud, Thibault; Gill, Nicholas; Kilduff, Liam P

    2015-01-01

    Reduced physical performance has been observed following the half-time period in team sports players, likely due to a decrease in muscle temperature during this period. We examined the effects of a passive heat maintenance strategy employed between successive exercise bouts on core temperature (Tcore) and subsequent exercise performance. Eighteen professional Rugby Union players completed this randomised and counter-balanced study. After a standardised warm-up (WU) and 15 min of rest, players completed a repeated sprint test (RSSA 1) and countermovement jumps (CMJ). Thereafter, in normal training attire (Control) or a survival jacket (Passive), players rested for a further 15 min (simulating a typical half-time) before performing a second RSSA (RSSA 2) and CMJ's. Measurements of Tcore were taken at baseline, post-WU, pre-RSSA 1, post-RSSA 1 and pre-RSSA 2. Peak power output (PPO) and repeated sprint ability was assessed before and after the simulated half-time. Similar Tcore responses were observed between conditions at baseline (Control: 37.06±0.05°C; Passive: 37.03±0.05°C) and for all other Tcore measurements taken before half-time. After the simulated half-time, the decline in Tcore was lower (-0.74±0.08% vs. -1.54±0.06%, p<0.001) and PPO was higher (5610±105 W vs. 5440±105 W, p<0.001) in the Passive versus Control condition. The decline in PPO over half-time was related to the decline in Tcore (r = 0.632, p = 0.005). In RSSA 2, best, mean and total sprint times were 1.39±0.17% (p<0.001), 0.55±0.06% (p<0.001) and 0.55±0.06% (p<0.001) faster for Passive versus Control. Passive heat maintenance reduced declines in Tcore that were observed during a simulated half-time period and improved subsequent PPO and repeated sprint ability in professional Rugby Union players. PMID:25785393

  9. Experimental evaluation of a breadboard heat and product-water removal system for a space-power fuel cell designed with static water removal and evaporative cooling

    NASA Technical Reports Server (NTRS)

    Hagedorn, N. H.; Prokipius, P. R.

    1977-01-01

    A test program was conducted to evaluate the design of a heat and product-water removal system to be used with fuel cell having static water removal and evaporative cooling. The program, which was conducted on a breadboard version of the system, provided a general assessment of the design in terms of operational integrity and transient stability. This assessment showed that, on the whole, the concept appears to be inherently sound but that in refining this design, several facets will require additional study. These involve interactions between pressure regulators in the pumping loop that occur when they are not correctly matched and the question of whether an ejector is necessary in the system.

  10. Removal of sulphur-containing odorants from fuel gases for fuel cell-based combined heat and power applications

    NASA Astrophysics Data System (ADS)

    de Wild, P. J.; Nyqvist, R. G.; de Bruijn, F. A.; Stobbe, E. R.

    Natural gas (NG) and liquefied petroleum gas (LPG) are important potential feedstocks for the production of hydrogen for fuel cell-based (e.g. proton exchange membrane fuel cells (PEMFC) or solid oxide fuel Cells (SOFC) combined heat and power (CHP) applications. To prevent detrimental effects on the (electro)catalysts in fuel cell-based combined heat and power installations (FC-CHP), sulphur removal from the feedstock is mandatory. An experimental bench-marking study of adsorbents has identified several candidates for the removal of sulphur containing odorants at low temperature. Among these adsorbents a new material has been discovered that offers an economically attractive means to remove TetraHydroThiophene (THT), the main European odorant, from natural gas at ambient temperature. The material is environmentally benign, easy to use and possesses good activity (residual sulphur levels below 20 ppbv) and capacity for the common odorant THT in natural gas. When compared to state-of-the-art metal-promoted active carbon the new material has a THT uptake capacity that is up to 10 times larger, depending on temperature and pressure. Promoted versions of the new material have shown potential for the removal of THT at higher temperatures and/or for the removal of other odorants such as mercaptans from natural gas or from LPG.

  11. Effects of duration of stay in temperate area on thermoregulatory responses to passive heat exposure in tropical south-east Asian males residing in Japan

    PubMed Central

    2012-01-01

    Background In this study, we investigated the effects of duration of stay in a temperate area on the thermoregulatory responses to passive heat exposure of residents from tropical areas, particularly to clarify whether they would lose their heat tolerance during passive heat exposure through residence in a temperate country, Japan. Methods We enrolled 12 males (mean ± SE age 25.7 ± 1.3 years) from south-east Asian countries who had resided in Japan for a mean of 24.5 ± 5.04 months, and 12 Japanese males (age 24.1 ± 0.9 years). Passive heat exposure was induced through leg immersion in hot water (42°C) for 60 minutes under conditions of 28°C air temperature and 50% relative humidity. Results Compared with the Japanese group, the tropical group displayed a higher pre-exposure rectal temperature (P < 0.01) and a smaller increase in rectal temperature during 60 minutes of leg immersion (P = 0.03). Additionally, the tropical group showed a tendency towards a lower total sweat rate (P = 0.06) and lower local sweat rate on the forehead (P = 0.07). The tropical group also had a significantly longer sweating onset time on the upper back (P = 0.04) compared with the Japanese groups. The tropical group who stayed in Japan for > 23 months sweated earlier on the forehead and upper back than those who stayed in Japan < 11 months (P < 0.01 and P = 0.03 for the forehead and upper back, respectively). There was a positive correlation between duration of stay in Japan and total sweat rate (r = 0.58, P <0.05), and negative correlations between duration of stay and sweating onset time on the forehead (r = −0.73, P = 0.01) and on the upper back (r = −0.66, P = 0.02). Other physiological indices measured in this study did not show any difference between the subjects in the tropical group who had lived in Japan for a shorter time and those who had lived there for a longer time. Conclusions We

  12. Institute for High Heat Flux Removal (IHHFR). Phases I, II, and III

    SciTech Connect

    Boyd, Ronald D.

    2014-08-31

    The IHHFR focused on interdisciplinary applications as it relates to high heat flux engineering issues and problems which arise due to engineering systems being miniaturized, optimized, or requiring increased high heat flux performance. The work in the IHHFR focused on water as a coolant and includes: (1) the development, design, and construction of the high heat flux flow loop and facility; (2) test section development, design, and fabrication; and, (3) single-side heat flux experiments to produce 2-D boiling curves and 3-D conjugate heat transfer measurements for single-side heated test sections. This work provides data for comparisons with previously developed and new single-side heated correlations and approaches that address the single-side heated effect on heat transfer. In addition, this work includes the addition of single-side heated circular TS and a monoblock test section with a helical wire insert. Finally, the present work includes: (1) data base expansion for the monoblock with a helical wire insert (only for the latter geometry), (2) prediction and verification using finite element, (3) monoblock model and methodology development analyses, and (4) an alternate model development for a hypervapotron and related conjugate heat transfer controlling parameters.

  13. Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown.

    SciTech Connect

    Tzanos, C.P.; Farmer, M.T.; Nuclear Engineering Division

    2007-08-31

    -normal operating conditions. The standpipes are headered (in groups of four in the prototype) to water supply (header) tanks that are situated well above the reactor vessel to facilitate natural convection cooling during a loss of forced flow event. During normal operations, the water is pumped from a heat sink located outside the containment to the headered inlets to the standpipes. The water is then delivered to each standpipe through a centrally located downcomer that passes the coolant to the bottom of each pipe. The water then turns 180{sup o} and rises up through the annular gap while extracting heat from the reactor cavity due to a combination of natural convection and radiation across the gap between the reactor vessel and standpipes. The water exits the standpipes at the top where it is headered (again in groups of four) into a return line that passes the coolant to the top of the header tank. Coolant is drawn from each tank through a fitting located near the top of the tank where it flows to the heat rejection system located outside the containment. This completes the flow circuit for normal operations. During off-normal conditions, forced convection water cooling in the RCCS is presumed to be lost, as well as the ultimate heat sink outside the containment. In this case, water is passively drawn from an open line located at the bottom of the header tank. This line is orificed so that flow bypass during normal operations is small, yet the line is large enough to provide adequate flow during passive operations to remove decay heat while maintaining acceptable fuel temperatures. In the passive operating mode, water flows by natural convection from the bottom of the supply tank to the standpipes, and returns through the normal pathway to the top of the tanks. After the water reaches saturation and boiling commences, steam will pass through the top of the tanks and be vented to atmosphere. In the experiment system shown in Fig. 4, a steam condensation and collection system is

  14. Topical report : CFD analysis for the applicability of the natural convection shutdown heat removal test facility (NSTF) for the simulation of the VHTR RCCS.

    SciTech Connect

    Tzanos, C. P.

    2007-05-16

    The Very High Temperature gas cooled reactor (VHTR) is one of the GEN IV reactor concepts that have been proposed for thermochemical hydrogen production and other process-heat applications like coal gasification. The United States Department of Energy has selected the VHTR for further research and development, aiming to demonstrate emissions-free electricity and hydrogen production at a future time. One of the major safety advantages of the VHTR is the potential for passive decay heat removal by natural circulation of air in a Reactor Cavity Cooling System (RCCS). The air-side of the RCCS is very similar to the Reactor Vessel Auxiliary Cooling System (RVACS) that has been proposed for the PRISM reactor design. The design and safety analysis of the RVACS have been based on extensive analytical and experimental work performed at ANL. The Natural Convection Shutdown Heat Removal Test Facility (NSTF) at ANL that simulates at full scale the air-side of the RVACS was built to provide experimental support for the design and analysis of the PRISM RVACS system. The objective of this work is to demonstrate that the NSTF facility can be used to generate RCCS experimental data: to validate CFD and systems codes for the analysis of the RCCS; and to support the design and safety analysis of the RCCS. At this time no reference design is available for the NGNP. The General Atomics (GA) gas turbine - modular helium reactor (GT-MHR) has been used in many analyses as a starting reference design. In the GT-MHR the reactor outlet temperature is 850 C, while the target outlet reactor temperature in VHTR is 1000 C. VHTR scoping studies with a reactor outlet temperature of 1000 C have been performed at GA and INEL. Although the reactor outlet temperature in the VHTR is significantly higher than in the GT-MHR, the peak temperature in the reactor vessel (which is the heat source for the RCCS) is not drastically different. In this work, analyses have been performed using reactor vessel

  15. Coolability of stratified UO/sub 2/ debris in sodium with downward heat removal: The D13 experiment

    SciTech Connect

    Ottinger, C.A.; Mitchell, G.W.; Reed, A.W.; Meister, H.

    1987-03-01

    The LMFBR Debris Coolability Program at Sandia National Laboratories investigates the coolability of particle beds that may form following a severe accident involving core disassembly in a nuclear reactor. The D series experiments utilize fission heating of fully enriched UO/sub 2/ particles submerged in sodium to realistically simulate decay heating. The D13 experiment is the first in the series to study the effects of bottom cooling of stratified debris, which could be provided in an actual accident condition by structural materials onto which the debris might settle. Additionally, the D13 experiment was designed to achieve maximum temperatures in the debris approaching the melting point of UO/sub 2/. The experiment was operated for over 40 hours and investigated downward heat removal at specific powers of 0.22 to 2.58 W/g. Channeled dryout in the debris was achieved at powers from 0.94 to 2.58 W/g. Maximum temperatures approaching 2700/sup 0/C were attained. Bottom heat removal was up to 750 kW/m/sup 2/ as compared to 450 kW/m/sup 2/ in the D10 experiment.

  16. Experimental investigations on decay heat removal in advanced nuclear reactors using single heater rod test facility: Air alone in the annular gap

    SciTech Connect

    Bopche, Santosh B.; Sridharan, Arunkumar

    2010-11-15

    During a loss of coolant accident in nuclear reactors, radiation heat transfer accounts for a significant amount of the total heat transfer in the fuel bundle. In case of heavy water moderator nuclear reactors, the decay heat of a fuel bundle enclosed in the pressure tube and outer concentric calandria tube can be transferred to the moderator. Radiation heat transfer plays a significant role in removal of decay heat from the fuel rods to the moderator, which is available outside the calandria tube. A single heater rod test facility is designed and fabricated as a part of preliminary investigations. The objective is to anticipate the capability of moderator to remove decay heat, from the reactor core, generated after shut down. The present paper focuses mainly on the role of moderator in removal of decay heat, for situation with air alone in the annular gap of pressure tube and calandria tube. It is seen that the naturally aspirated air is capable of removing the heat generated in the system compared to the standstill air or stagnant water situations. It is also seen that the flowing moderator is capable of removing a greater fraction of heat generated by the heater rod compared to a stagnant pool of boiling moderator. (author)

  17. Removal of milk fat globules from whey protein concentrate 34% to prepare clear and heat-stable protein dispersions.

    PubMed

    Liu, Gang; Zhong, Qixin

    2014-10-01

    Whey protein concentrates (WPC) are low-cost protein ingredients, but their application in transparent ready-to-drink beverages is limited due to turbidity caused by fat globules and heat instability. In this work, fat globules were removed from WPC 34% (WPC-34) to prepare heat-stable ingredients via the Maillard reaction. The removal of fat globules by acid precipitation and centrifugation was observed to be the most complete at pH 4.0, and the loss of protein was caused by micrometer-sized fat globules and protein aggregates. Spray-dried powder prepared from the transparent supernatant was glycated at 130°C for 20 and 30min or 60°C for 24 and 48h. The 2 groups of samples had comparable heat stability and degree of glycation, evaluated by free amino content and analytical ultracentrifugation, but high-temperature, short-time treatment reduced the color formation during glycation. Therefore, WPC-34 can be processed for application in transparent beverages. PMID:25108870

  18. Passive heating following the prematch warm-up in soccer: examining the time-course of changes in muscle temperature and contractile function.

    PubMed

    Marshall, Paul W M; Cross, Rebecca; Lovell, Ric

    2015-12-01

    This study examined changes in muscle temperature, electrically evoked muscle contractile properties, and voluntary power before and after a soccer specific active warm-up and subsequent rest period. Ten amateur soccer players performed two experimental sessions that involved performance of a modified FIFA 11+ soccer specific warm-up, followed by a 12.5-min rest period where participants were required to wear either normal clothing or a passive electrical heating garment was applied to the upper thigh muscles. Assessments around the warm-up and cool-down included measures of maximal torque, rate of torque development, muscle temperature (Tm), and electrically evoked measures of quadriceps contractile function. Tm was increased after the warm-up by 3.2 ± 0.7°C (P < 0.001). Voluntary and evoked rates of torque development increased after the warm-up between 20% and 30% (P < 0.05), despite declines in both maximal voluntary torque and voluntary activation (P < 0.05). Application of a passive heating garment in the cool-down period after the warm-up did not effect variables measured. While Tm was reduced by 1.4 ± 0.4°C after the rest period (P < 0.001), this value was still higher than pre warm-up levels. Voluntary and evoked rate of torque development remained elevated from pre warm-up levels at the end of the cool-down (P < 0.05). The soccer specific warm-up elevated muscle temperature by 3.2°C and was associated with concomitant increases of between 20% and 30% in voluntary rate of torque development, which seems explained by elevations in rate-dependent measures of intrinsic muscle contractile function. Application of a passive heating garment did not attenuate declines in muscle temperature during a 12.5-min rest period. PMID:26634901

  19. Development of Passive Fuel Cell Thermal Management Technology

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian; Colozza, Anthony

    2011-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA exploration program. The passive thermal management system relies on heat conduction within the cooling plate to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack rather than using a pumped loop cooling system to convectively remove the heat. Using the passive approach eliminates the need for a coolant pump and other cooling loop components which reduces fuel cell system mass and improves overall system reliability. Previous analysis had identified that low density, ultra-high thermal conductivity materials would be needed for the cooling plates in order to achieve the desired reductions in mass and the highly uniform thermal heat sink for each cell within a fuel cell stack. A pyrolytic graphite material was identified and fabricated into a thin plate using different methods. Also a development project with Thermacore, Inc. resulted in a planar heat pipe. Thermal conductivity tests were done using these materials. The results indicated that lightweight passive fuel cell cooling is feasible.

  20. Passive System Reliability Analysis: A Study on the Isolation Condenser

    SciTech Connect

    Burgazzi, Luciano

    2002-07-15

    This paper deals with the reliability assessment of passive systems that have been developed in recent years by suppliers, industries, utilities, and research organizations, aimed at plant safety improvement and substantial simplification in its implementation. The present study concerns the passive decay heat removal systems that use, for the most part, a condenser immersed in a cooling pool. The focus of the paper is a reliability study of the isolation condenser system foreseen for advanced boiling water reactors (BWRs) for the removal of the excess sensible and core decay heat from the BWR by natural circulation. Furthermore, an approach aimed at the thermal-hydraulic performance assessment (i.e., the natural circulation failure evaluation) from the probability point of view is given. The study is not plant-specific-related but pertains to the conceptual design of the foregoing system.

  1. When to defrost a refrigerator, and when to remove the scale from the heat exchanger of a power plant

    NASA Astrophysics Data System (ADS)

    Bejan, Adrian; Vargas, Jose V. C.; Lim, Jong S.

    1995-02-01

    This paper demonstrates the existence of an optimal on/off sequence for operating a household refrigerator that accumulates ice on its evaporator coils. Experimentally it is shown that the rate of ice formation is constant in time. The optimal (intermittent) regime of operation determined in this paper minimizes the power required by the refrigerator, maintains the prescribed temperature of the cold space, and removes intermittently the ice layer. The second part of the paper proves that a similar strategy can be used for dealing with fouling in heat exchangers, i.e. for maximizing the power output of a power plant that is diminished by the formation of scale on its heat exchanger surfaces.

  2. Comparison of Tobacco Host Cell Protein Removal Methods by Blanching Intact Plants or by Heat Treatment of Extracts.

    PubMed

    Buyel, Johannes F; Hubbuch, Jürgen; Fischer, Rainer

    2016-01-01

    Plants not only provide food, feed and raw materials for humans, but have also been developed as an economical production system for biopharmaceutical proteins, such as antibodies, vaccine candidates and enzymes. These must be purified from the plant biomass but chromatography steps are hindered by the high concentrations of host cell proteins (HCPs) in plant extracts. However, most HCPs irreversibly aggregate at temperatures above 60 °C facilitating subsequent purification of the target protein. Here, three methods are presented to achieve the heat precipitation of tobacco HCPs in either intact leaves or extracts. The blanching of intact leaves can easily be incorporated into existing processes but may have a negative impact on subsequent filtration steps. The opposite is true for heat precipitation of leaf extracts in a stirred vessel, which can improve the performance of downstream operations albeit with major changes in process equipment design, such as homogenizer geometry. Finally, a heat exchanger setup is well characterized in terms of heat transfer conditions and easy to scale, but cleaning can be difficult and there may be a negative impact on filter capacity. The design-of-experiments approach can be used to identify the most relevant process parameters affecting HCP removal and product recovery. This facilitates the application of each method in other expression platforms and the identification of the most suitable method for a given purification strategy. PMID:27584939

  3. Removal of numerical instability in the solution of an inverse heat conduction problem

    NASA Astrophysics Data System (ADS)

    Pourgholi, R.; Azizi, N.; Gasimov, Y. S.; Aliev, F.; Khalafi, H. K.

    2009-06-01

    In this paper, we consider an inverse heat conduction problem (IHCP). A set of temperature measurements at a single sensor location inside the heat conduction body is required. Using a transformation, the ill-posed IHCP becomes a Cauchy problem. Since the solution of Cauchy problem, exists and is unique but not always stable, the ill-posed problem is closely approximated by a well-posed problem. For this new well-posed problem, the existence, uniqueness, and stability of the solution are proved.

  4. Enhancing VHTR Passive Safety and Economy with Thermal Radiation Based Direct Reactor Auxiliary Cooling System

    SciTech Connect

    Haihua Zhao; Hongbin Zhang; Ling Zou; Xiaodong Sun

    2012-06-01

    One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The decay heat first is transferred to the core barrel by conduction and radiation, and then to the reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface area). When the relative decay heat removal capability decreases, the peak fuel temperature increases, even close to the design limit. Annular core designs with inner graphite reflector can mitigate this effect; therefore can further increase the reactor power. Another way to increase the reactor power is to increase power density. However, the reactor power is also limited by the decay heat removal capability. Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environment side. For the reactor side, cooling pipes will be inserted into holes made in the outer or

  5. Passive Warming using a Heat-Band versus a Resistive Heating Blanket for the Prevention of Inadvertent Perioperative Hypothermia during Laparotomy for Gynaecological Surgery

    PubMed Central

    Wan Fadzlina, Wan Muhd Shukeri; Wan Mohd Nazaruddin, Wan Hassan; Rhendra Hardy, Mohamad Zaini

    2016-01-01

    Background Inadvertent perioperative hypothermia (IPH) is a common problem, despite advancements in a variety of warming systems. The use of a resistive heating blanket (RHB) is a common but costly approach to patient warming. We have introduced the use of a heat-band in our centre as a cost-effective alternative to the RHB for patient warming. The efficacy of the heat-band in preventing IPH during laparotomy for gynaecological surgeries was compared with that of the RHB. Methods Thirty-two patients undergoing surgeries under combined general-epidural anaesthesia, with an expected duration of surgery of 2–4 h, were randomised to receive either the heat-band or RHB. The core body temperatures of the two groups were compared at several perioperative times, in addition to the incidence of post-anaesthesia shivering, time to extubation and intraoperative blood loss. Results The core body temperatures were comparable between the two groups in the pre-operative period, immediately after the induction of anaesthesia and skin incision, 1 h after the incision, at the time of complete skin closing, at extubation, upon arrival to the recovery room and 1 h post-operatively. There were no significant between-group differences in the incidence of post-anaesthesia shivering, time to extubation and intra-operative blood loss. Conclusion The heat-band is as effective as the RHB in preventing IPH and its complications in gynaecological laparotomies. PMID:27547112

  6. Heat removal from high temperature tubular solid oxide fuel cells utilizing product gas from coal gasifiers.

    SciTech Connect

    Parkinson, W. J. ,

    2003-01-01

    In this work we describe the results of a computer study used to investigate the practicality of several heat exchanger configurations that could be used to extract heat from tubular solid oxide fuel cells (SOFCs) . Two SOFC feed gas compositions were used in this study. They represent product gases from two different coal gasifier designs from the Zero Emission Coal study at Los Alamos National Laboratory . Both plant designs rely on the efficient use of the heat produced by the SOFCs . Both feed streams are relatively rich in hydrogen with a very small hydrocarbon content . One feed stream has a significant carbon monoxide content with a bit less hydrogen . Since neither stream has a significant hydrocarbon content, the common use of the endothermic reforming reaction to reduce the process heat is not possible for these feed streams . The process, the method, the computer code, and the results are presented as well as a discussion of the pros and cons of each configuration for each process .

  7. Impact of Sn(S,Se) secondary phases in Cu2ZnSn(S,Se)4 solar cells: a chemical route for their selective removal and absorber surface passivation.

    PubMed

    Xie, Haibing; Sánchez, Yudania; López-Marino, Simón; Espíndola-Rodríguez, Moisés; Neuschitzer, Markus; Sylla, Diouldé; Fairbrother, Andrew; Izquierdo-Roca, Victor; Pérez-Rodríguez, Alejandro; Saucedo, Edgardo

    2014-08-13

    The control and removal of secondary phases is one of the major challenges for the development of Cu2ZnSn(S,Se)4 (CZTSSe)-based solar cells. Although etching processes have been developed for Cu(S,Se), Zn(S,Se), and CuSn(S,Se) secondary phases, so far very little attention has been given to the role of Sn(S,Se). In this paper, we report a chemical route using a yellow (NH4)2S solution to effectively remove Sn(S,Se). We found that Sn(S,Se) can form on the surface either because of stoichiometric deviation or by condensation. After etching, the efficiency of devices typically increases between 20 and 65% relative to the before etch efficiencies. We achieved a maximum 5.9% efficiency in Se-rich CZTSSe-based devices. It is confirmed that this feature is related not only to the removal of Sn(S,Se) but also to the unexpected passivation of the surface. We propose a phenomenological model for this passivation, which may open new perspectives for the development of CZTSSe-based solar cells. PMID:25033026

  8. Conceptual Design of Passive Safety System for Lead-Bismuth Cooled Fast Reactor

    NASA Astrophysics Data System (ADS)

    Abdullah, A. G.; Nandiyanto, A. B. D.

    2016-04-01

    This paper presents the results of the conceptual design of passive safety systems for reactor power 225 MWth using Pb-Bi coolant. Main purpose of this research is to design of heat removal system from the reactor wall. The heat from the reactor wall is removed by RVACS system using the natural circulation from the atmosphere around the reactor at steady state. The calculation is performed numerically using Newton-Raphson method. The analysis involves the heat transfer systems in a radiation, conduction and natural convection. Heat transfer calculations is performed on the elements of the reactor vessel, outer wall of guard vessel and the separator plate. The simulation results conclude that the conceptual design is able to remove heat 1.33% to 4.67% from the thermal reactor power. It’s can be hypothesized if the reactor had an accident, the system can still overcome the heat due to decay.

  9. Removal of Pb(II) from water by the activated carbon modified by nitric acid under microwave heating.

    PubMed

    Yao, Shuheng; Zhang, Jiajun; Shen, Dekui; Xiao, Rui; Gu, Sai; Zhao, Ming; Liang, Junyu

    2016-02-01

    The rice husk based activated carbon (RH-AC) was treated by nitric acid under microwave heating, in order to improve its capability for the removal of heavy metal ions from water. The optimal conditions for the modification of RH-AC (M-RH-AC) were determined by means of orthogonal array experimental design, giving those as the concentration of nitric acid of 8mol/L, modification time of 15min, modification temperature of 130°C and microwave power of 800W. The characteristics of the M-RH-AC and RH-AC were examined by BET, XRD, Raman spectrum, pH titration, zeta potential, Boehm titration and FTIR analysis. The M-RH-AC has lower pore surface area, smaller crystallite, lower pHIEP and more oxygen-containing functional groups than the RH-AC. Removal capacity of Pb(II) ions by the M-RH-AC and RH-AC from water solution was estimated concerning the influence of contact time, pH value, and initial concentration. The equilibrium time of Pb(II) removal was found to be around 90min after modification process. Two kinetic models are adopted to describe the possible Pb(II) adsorption mechanism, finding that the adsorption rate of Pb(II) ions by the M-RH-AC is larger than that of RH-AC. PMID:26520818

  10. A passively-fed methanol steam reformer heated with two-stage bi-fueled catalytic combustor

    NASA Astrophysics Data System (ADS)

    Lo, Kai-Fan; Wong, Shwin-Chung

    2012-09-01

    This paper presents further progress on our simple novel passively-fed methanol steam reformer. The present study focuses on the development of a catalytic combustor workable with both hydrogen and methanol fuels. The aim is to reutilize the exhaust hydrogen from a fuel cell under stable operation but burn methanol during the start-up. On a copper plate, the catalytic combustor in a u-turn channel is integrally machined under a two-turn serpentine-channel reformer. To resolve the highly different fuel reactivities, a suitably diluted catalyst formula demonstrates uniform temperature distributions burning with either liquid methanol or an H2/CO2 mixture simulating the exhaust gas from a fuel cell. In a two-stage process, it first takes 25 min to reach 270 °C by burning methanol. After the fuel is switched to the H2/CO2 mixture, another 20 min is needed to attain an optimal steady state which yields a high methanol conversion of 95% and acceptably low CO fraction of 1.04% at a reaction temperature of 278 °C. The H2 and CO2 concentrations are 75.1% and 23.6%.

  11. D9 experiment: heat removal from stratified UO/sub 2/ debris

    SciTech Connect

    Ottinger, C A; Mitchell, G W; Lipinski, R J; Kelly, J E

    1985-04-01

    The D9 experiment investigated the coolability of a shallow (77 mm), stratified urania bed in sodium. The bed was fission heated in the Annular Core Research Reactor (ACRR) at Sandia National Laboratories to simulate the effects of radioactive decay heating. It was the first stratified debris bed experiment to use an extended UO/sub 2/ particle size distribution (0.038 to 4.0 mm). Dryout occurred at powers ranging from 0.10 to 0.58 W/g, which was close to the incipient boiling power and before channels penetrated the subcooled zone in the bed, even with subcoolings as low as 80/sup 0/C. Channel penetration was observed after dryout began, but the bed became only moderately more coolable. All these observations agree with current models.

  12. Composition of incipient passivating layers on heat-rejecting aluminum in carboxylate- and silicate-inhibited coolants: Correlation with ASTM D 4340 weight losses

    SciTech Connect

    Wagner, F.T.; Moylan, T.E.; Simko, S.J.; Militello, M.C.

    1999-08-01

    X-ray photoelectron spectroscopy identified compositional differences between passivating layers initially formed in carboxylated coolants, in silicated coolants, and in a mixture thereof on well-controlled 319 aluminum surfaces under heat-rejecting conditions. The layer formed in silicated coolant was primarily silica, while that in carboxylated coolant was primarily hydrated alumina. Competition between inhibitor packages when carboxylated coolant was contaminated from the start with low levels of silicated coolant produced films which were not simply patchwise mixtures of the pure-coolant film types. The surface analytical results aid the interpretation of subtle differences in weight losses under the ASTM Standard Test Method for Corrosion of Cast Aluminum Alloys in Engine Coolants Under Heat-Rejecting Conditions (D 4340) in carboxylated versus silicated coolants that became more pronounced when testing was carried out at a vehicle-like 50% coolant concentration. Results from time-resolved D4340 measurements and from a two-step cleaning procedure further contribute towards proper evaluation of D4340 weight losses in the different coolant types.

  13. Removal of PCDDs/DFs and dl-PCBs in MWI fly ash by heating under vacuum.

    PubMed

    Misaka, Youhei; Yamanaka, Kazushi; Takeuchi, Kazuhiko; Sawabe, Kyoichi; Shobatake, Kosuke

    2006-07-01

    Temperature dependence of PCDD/DF and dioxin-like polychlorinated biphenyl (dl-PCB) concentrations in fly ash from a municipal waste incinerator (MWI) heated under vacuum has been investigated as a function of sample temperature ranging from T(s)=425 to 800 K to find out if PCDDs/DFs in fly ash evaporate and are trapped in a liquid nitrogen-cooled trap. The results show that more than 99.98% of PCDDs/DFs in TEQ is removed from fly ash by vacuum heat treatment at T(s)>650 K for 4 h. Almost no PCDDs/DFs were detected in the liquid nitrogen-cooled trap. Homologue distributions indicate that dechlorination/hydrogenation (DCH) reactions proceed in fly ash at T(s)>450 K. Arrhenius rate parameters for the DCH reactions have been determined for each homologue assuming that only DCH reactions occur. The fly ash heated under vacuum at 650 or 800 K was reheated at 573 K (300 degrees C) in a stream of dry or humid air to see how much PCDDs/DFs and dl-PCBs are regenerated. We have found that (1) PCDDs/DFs are regenerated in both 650 K and 800 K treated fly ash, whereas dl-PCBs are regenerated in 650 K treated fly ash, (2) formation of PCDFs predominates over that of PCDDs or dl-PCBs, and (3) less chlorinated homologues are abundant for PCDDs/DFs and dl-PCBs. PMID:16384596

  14. D10 experiment: coolability of UO/sub 2/ debris in sodium with downward heat removal. [LMFBR

    SciTech Connect

    Mitchell, G.W.; Ottinger, C.A.; Meister, H.

    1984-12-01

    The LMFBR Debris Coolability Program at Sandia National Laboratories investigates the coolability of particle beds which may form following a severe accident involving core disassembly in a nuclear reactor. The D series experiments utilize fission heating of fully enriched UO/sub 2/ particles submerged in sodium to realistically simulate decay heating. The D10 experiment is the first in the series to study the effects of bottom cooling of the debris that could be provided in an actual accident condition by structural materials onto which the debris might settle. Additionally, the D10 experiment was designed to achieve maximum temperatures in the debris approaching the melting point of UO/sub 2/. The experiment was successfully operated for over 50 hours and investigated downward heat removal in a packed bed at specific powers of 0.16 to 0.58 W/g. Dryout in the debris was achieved at powers from 0.42 to 0.58 W/g. Channels were induced in the bed and channeled bed dryout was achieved at powers of 1.06 to 1.77 W/g. Maximum temperatures in excess of 2500/sup 0/C were attained.

  15. Chromatographic removal and heat inactivation of hepatitis B virus during the manufacture of human albumin.

    PubMed

    Adcock, W L; MacGregor, A; Davies, J R; Hattarki, M; Anderson, D A; Goss, N H

    1998-10-01

    The purpose of the present study was to examine the efficacy of the chromatographic and pasteurization steps, employed in the manufacture of human albumin, in the removal and/or inactivation of hepatitis B virus (HBV). Most human albumins manufactured today are prepared from donor plasma by fractionation methods that use precipitation with cold ethanol. CSL Limited, an Australian biopharmaceutical company, has recently converted its method of manufacture for albumin from a traditional Cohn fractionation method to a method employing chromatographic techniques. A step-by-step validation of virus removal and inactivation was performed on this manufacturing process, which includes a DEAE-Sepharose(R) and CM-Sepharose(R) Fast Flow ion-exchange step, a Sephacryl(R) S200 High-Resolution gel-filtration step and a bulk pasteurization step where product is held at 60 degreesC for 10 h. HBV partitioning experiments were conducted on scaled-down chromatographic columns with hepatitis B surface antigen (HBsAg) as a marker, whereas the HBV model virus, duck HBV, was used to study the inactivation kinetics during pasteurization. Reductions for HBsAg through the three chromatographic steps resulted in a total log10 decrease of 1.5 log10, whereas more than 6.5 log10 decrease in duck HBV in Albumex(R)5 was achieved during pasteurization. PMID:9756468

  16. Demonstration of a high heat removal CVD diamond substrate edge-cooled multichip module

    SciTech Connect

    Peterson, D.W.; Sweet, J.N.; Andaleon, D.D.; Renzi, R.F.; Johnson, D.R.

    1994-05-01

    A single substrate intended for a 3-dimensional (3D) edge-cooled multichip module (MCM) has been built and thermally tested. The substrate, with dimensions 1.9 in. by 2 in., is mounted in a fluid cooled block at one end. To test this cooling architecture and verify the accuracy of thermal models, the authors constructed thermal test modules using alumina (Al{sub 2}O{sub 3}), aluminum nitride (AlN), and CVD diamond substrate materials. Each module was populated with an array of 16 Sandia ATC03 test chips with resistive heaters and temperature sensing diode thermometers. Comparative measurements of the 3 substrates were made in which the top row of 4 die were heated at 5 W each for a total of 20 W. The maximum temperature differences between the heated die and the interface with the cold chuck, {delta}T{sub js}, were 24, 126, and 265{degrees}C for diamond, AIN and alumina, respectively. Measurements on the diamond thermal test module, uniformly heated at a total power of 40 W, gave a measured junction-to-sink temperature of {delta}T{sub js} = 18{degrees}C. This result indicates that the diamond edge-cooled substrate could dissipate a total power {approximately}200 W for a maximum {delta}T{sub js} {approximately}100{degrees}C. If multiple substrates were mounted in the fluid cooled block, spaced 0.075 in. apart, the volumetric power density would be about 880 W/in.

  17. Regional relation between skin blood flow and sweating to passive heating and local administration of acetylcholine in young, healthy humans

    PubMed Central

    Kenney, W. Larry; Alexander, Lacy M.

    2013-01-01

    Regional variation in sweating over the human body is widely recognized yet variation in vasomotor responses and mechanisms causing this variation remain unclear. This study aimed to explore the relation between regional sweating rates (RSR) and skin blood flow (SkBF) responses to thermal and pharmacological stimuli in young, healthy subjects. In nine subjects (23 ± 3 yr), intradermal microdialysis (MD) probes were inserted into the ventral forearm, abdomen, thigh, and lower back and perfused with lactated Ringer solution. RSR over each MD membrane were measured using ventilated capsules with a laser Doppler probe housed in each capsule for measurement of red cell flux (laser Doppler flux, LDF) as an index of SkBF. Subjects completed a whole body heating protocol to 1°C rise in oral temperature and an acetylcholine dose response (ACh 1 × 10−7-0.1 M; mean skin temperature 34°C). Maximal LDF were obtained at the end of both protocols (50 mM sodium nitroprusside).During heating RSR varied among sites (P < 0.0001) and was greater on the back versus other sites (P < 0.05), but LDF was similar between sites (P = 0.343). RSR and SkBF showed a strong relation during initial (arm: r = 0.77 ± 0.09, thigh: r = 0.81 ± 0.08, abdomen: r = 0.89 ± 0.04, back: r = 0.86 ± 0.04) but not latter stages of heating. No differences in RSR (P = 0.160) or SkBF (LDF, P = 0.841) were observed between sites during ACh perfusion. Taken together, these data suggest that increases in SkBF are necessary to initiate and increase sweating, but further rises in RSR are not fully dependent on SkBF in a dose-response manner. Furthermore, RSR cannot be explained by cholinergic sensitivity or variation in SkBF. PMID:23389110

  18. Investigation of temporal-spatial parameters of an urban heat island on the basis of passive microwave remote sensing

    NASA Astrophysics Data System (ADS)

    Khaikine, M. N.; Kuznetsova, I. N.; Kadygrov, E. N.; Miller, E. A.

    2006-02-01

    Quantitative measurements of the impact of an urban environment on the thermal state of the atmospheric boundary layer are presented. Temperature profiles up to the height of 600 m were obtained in a continuous series of measurements by three microwave profilers MTP-5 located in different areas of Moscow. The influence of this large city on urban heat island (UHI) parameters was estimated on occasions with stationary atmospheric processes and during cases with frontal passage. Two types of UHI were identified: one with a dome of urban warmth at all levels, and another with a low warm dome in combination with a lens of cold air above.

  19. High Heat Flux Interactions and Tritium Removal from Plasma Facing Components by a Scanning Laser

    SciTech Connect

    C.H. Skinner; C.A. Gentile; A. Hassanein

    2002-01-28

    A new technique for studying high heat flux interactions with plasma facing components is presented. The beam from a continuous wave 300 W neodymium laser was focused to 80 W/mm2 and scanned at high speed over the surface of carbon tiles. These tiles were previously used in the TFTR [Tokamak Fusion Test Reactor] inner limiter and have a surface layer of amorphous hydrogenated carbon that was codeposited during plasma operations. Laser scanning released up to 84% of the codeposited tritium. The temperature rise of the codeposit on the tiles was significantly higher than that of the manufactured material. In one experiment, the codeposit surface temperature rose to 1,770 C while for the same conditions, the manufactured surface increased to only 1,080 C. The peak temperature did not follow the usual square-root dependence on heat pulse duration. Durations of order 100 ms resulted in brittle destruction and material loss from the surface, while a duration of approximately 10 ms showed minimal change. A digital microscope imaged the codeposit before, during, and after the interaction with the laser and revealed hot spots on a 100-micron scale. These results will be compared to analytic modeling and are relevant to the response of plasma facing components to disruptions and vertical displacement events (VDEs) in next-step magnetic fusion devices.

  20. Organic compound destruction and removal efficiency (DRE) for plasma incinerator off-gases using an electrically heated secondary combustion chamber

    SciTech Connect

    Whitworth, C.G.; Babko-Malyi, S.; Battleson, D.M.; Olstad, S.J.

    1998-12-31

    The US Department of Energy (DOE) sponsored a series pilot-scale plasma incineration tests of simulated mixed wastes at the MSE Technology Applications, Inc. technology development test facility in Butte, MT. One of the objectives of the test series was to assess the ability of an electrically heated afterburner to destroy organic compounds that may be present in the off-gases resulting from plasma incineration of mixed wastes. The anticipated benefit of an electrically heated afterburner was to decrease total off-gas volume by 50% or more, relative to fossil fuel-fired afterburners. For the present test series, feeds of interest to the DOE Mixed Waste Focus Area (MWFA) were processed in a plasma centrifugal furnace while metering selected organic compounds upstream of the electrically heated afterburner. The plasma furnace was equipped with a transferred-mode torch and was operated under oxidizing conditions. Feeds consisted of various mixtures of soil, plastics, portland cement, silicate fines, diesel fuel, and scrap metals. Benzene, chloroform, and 1,1,1-trichloroethane were selected for injection as simulates of organics likely to be present in DOE mixed wastes, and because of their relative rankings on the US Environmental Protection Agency (EPA) thermal stability index. The organic compounds were injected into the off-gas system at a nominal concentration of 2,000 ppmv. The afterburner outlet gas stream was periodically sampled, and analyzed by gas chromatography/mass spectrometry. For the electrically heated afterburner, at operating temperatures of 1,800--1,980 F (982--1,082 C), organic compound destruction and removal efficiencies (DREs) for benzene, chloroform, and 1,1,1-trichloroethane were found to be > 99.99%.

  1. Enhancement of heat removal using concave liquid metal targets for high-power accelerators.

    SciTech Connect

    Konkashbaev, I.; Fischer, P.; Hassanein, A.; Mokhov, N. V.; Mathematics and Computer Science; FNAL

    2007-01-01

    The need is increasing for development of high-power targets and beam dump areas for the production of intense beams of secondary particles. The severe constraints arising from a megawatt beam deposited on targets and absorbers call for nontrivial procedures to dilute the beam. This study describes the development of targets and absorbers and the advantages of using flowing liquid metal in concave channels first proposed by IFMIF to raise the liquid metal boiling point by increasing the pressure in liquid supported by a centrifugal force. Such flow with a back-wall is subject to Taylor-Couette instability. The instability can play a positive role of increasing the heat transfer from the hottest region in the target/absorber to the back-wall cooled by water. Results of theoretical analysis and numerical modeling of both targets and dump areas for the IFMIF, ILC, and RIA facilities are presented.

  2. Thermal-hydraulic processes involved in loss of residual heat removal during reduced inventory operation. Revision 1

    SciTech Connect

    Fletcher, C.D.; McHugh, P.R.; Naff, S.A.; Johnsen, G.W.

    1991-02-01

    This paper identifies the topics needed to understand pressurized water reactor response to an extended loss of residual heat removal event during refueling and maintenance outages. By identifying the possible plant conditions and cooling methods that would be used for each cooling mode, the controlling thermal-hydraulic processes and phenomena were identified. Controlling processes and phenomena include: gravity drain, core water boil-off, and reflux cooling processes. Important subcategories of the reflux cooling processes include: the initiation of reflux cooling from various plant conditions, the effects of air on reflux cooling, core level depression effects, issues regarding the steam generator secondaries, and the special case of boiler-condenser cooling with once-through steam generators. 25 refs., 6 figs., 1 tab.

  3. Airborne Passive Microwave Measurements from the AMISA 2008 Science Campaign for Modeling of Arctic Sea Ice Heating

    NASA Astrophysics Data System (ADS)

    Zucker, M. L.; Gasiewski, A. J.; CenterEnvironmental Technology

    2011-12-01

    While climate changes in the Arctic are occurring more rapidly than anywhere else on Earth model-based predictions of sea ice extent are at once both more optimistic than the data suggest and exhibit a high degree of variability. It is believed that this high level of uncertainty is the result of an inadequate quantitative understanding of surface heating mechanisms, which in large part is due to a lack of high spatial resolution data on boundary layer and surface energy processes during melt and freezeup. In August 2008 the NASA Arctic Mechanisms of Interactions between the Surface and Atmosphere (AMISA) campaign, in conjunction with the Swedish-led Arctic Summer Cloud-Ocean Study (ASCOS) conducted coordinated high spatial resolution measurements of geophysical parameters in the Arctic relevant to atmospheric-sea ice interaction. The IPY-approved AMISA campaign used airborne radiometers, including the Polarimetric Scanning Radiometer (PSR) system, a suite of L-band to V-band fixed-beam radiometers for cloud liquid and water vapor measurement, short and longwave radiation sensors, meteorological parameters from cloud size distribution probes, GPS dropsondes, and aerosol sensors. Calibration of the PSR is achieved through periodic observations of stable references such as thermal blackbody targets and noise diodes. A combination of methods using both infrequent external thermal blackbody views and brief frequent internal noise sources has proven practical for airborne systems such as the PSR and is proposed for spaceborne systems such as GeoMAS. Once radiometric data is calibrated it is then rasterized into brightness temperature images which are then geo-located and imported into Google EarthTM. An example brightness temperature map from the AMISA 2008 campaign is included in this abstract. The analysis of this data provides a basis for the development of a heat flux model needed to decrease the uncertainly in weather and climate predictions within the Arctic. In

  4. Westinghouse Small Modular Reactor passive safety system response to postulated events

    SciTech Connect

    Smith, M. C.; Wright, R. F.

    2012-07-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor. This paper is part of a series of four describing the design and safety features of the Westinghouse SMR. This paper focuses in particular upon the passive safety features and the safety system response of the Westinghouse SMR. The Westinghouse SMR design incorporates many features to minimize the effects of, and in some cases eliminates the possibility of postulated accidents. The small size of the reactor and the low power density limits the potential consequences of an accident relative to a large plant. The integral design eliminates large loop piping, which significantly reduces the flow area of postulated loss of coolant accidents (LOCAs). The Westinghouse SMR containment is a high-pressure, compact design that normally operates at a partial vacuum. This facilitates heat removal from the containment during LOCA events. The containment is submerged in water which also aides the heat removal and provides an additional radionuclide filter. The Westinghouse SMR safety system design is passive, is based largely on the passive safety systems used in the AP1000{sup R} reactor, and provides mitigation of all design basis accidents without the need for AC electrical power for a period of seven days. Frequent faults, such as reactivity insertion events and loss of power events, are protected by first shutting down the nuclear reaction by inserting control rods, then providing cold, borated water through a passive, buoyancy-driven flow. Decay heat removal is provided using a layered approach that includes the passive removal of heat by the steam drum and independent passive heat removal system that transfers heat from the primary system to the environment. Less frequent faults such as loss of coolant accidents are mitigated by passive injection of a large quantity of water that is readily available inside containment. An automatic depressurization system is used to

  5. TRANSIENT HEAT TRANSFER ANALYSIS FOR ION-EXCHANGE WASTE REMOVAL PROCESS

    SciTech Connect

    Lee, S.

    2010-07-12

    The small column ion exchange (SCIX) process treats low curie salt (LCS) waste before feeding it to the saltstone facility to be made into grout. Through this process, radioactive cesium from the salt solution is absorbed into the CST bed. A CST column loaded with radioactive cesium will generate significant heat from radiolytic decay. If engineering designs of the CST sorption column can not handle this thermal load, hot spots may develop locally within the column and degrade the performance of the ion-exchange process. The CST starts to degrade at about 80 to 85 C, and the CST completely changes to another material above 120 C. In addition, the process solution will boil around 130 C. If the column boiled dry, the sorbent could plug the column and require replacement of the column module. The objective of the present work is to compute temperature distributions across the column as a function of transit time after the initiation of accidents when there is loss of the salt solution flow in the CST column under abnormal conditions of the process operations. In this situation, the customer requested that the calculations should be conservative in that the model results would show the maximum centerline temperatures achievable by the CST design configurations. The thermal analysis results will be used to evaluate the fluid temperature distributions and the process component temperatures within the ion exchange system. This information will also assist in the system design and maintenance.

  6. Chromatographic removal and heat inactivation of hepatitis A virus during manufacture of human albumin.

    PubMed

    Adcock, W L; MacGregor, A; Davies, J R; Hattarki, M; Anderson, D A; Goss, N H

    1998-08-01

    CSL Limited, an Australian biopharmaceutical company, has recently converted its method of manufacture for human albumin from a traditional Cohn-ethanol fractionation method to a method employing chromatographic techniques. Studies were undertaken to determine the efficiency of the chromatographic and pasteurization steps used in the manufacture of Albumex(R) (CSL's trade name for albumin) in removing and inactivating the potential viral contaminant, hepatitis A virus (HAV). The manufacturing process for Albumex(R) includes three chromatographic steps, two of which are ion-exchange steps (DEAE-Sepharose(R) Fast Flow and CM-Sepharose(R) Fast Flow) and the third is a gel-filtration step (Sephacryl(R) S200 HR). The final stage of the Albumex(R) process involves a bulk pasteurization step where product is held at 60 degrees C for 10 h. HAV partitioning experiments on the DEAE-Sepharose(R) FF and CM-Sepharose(R) FF ion-exchange and Sephacryl(R) S200 HR gel-filtration columns were performed with scaled-down models of the production-scale chromatographic Albumex(R) process. Production samples collected before each of the chromatographic steps were spiked with HAV and processed through each of the scaled-down chromatographic columns. Samples collected during processing were assayed and the log10 reduction factors calculated. Inactivation kinetics of HAV were examined during the pasteurization of Albumex(R) 5 and 20 [5% and 20% (w/v) albumin solutions] held at 60 degrees C for 10 h. Log10 reductions for HAV through the DEAE-Sepharose(R) FF, CM-Sepharose(R) FF and Sephacryl(R) S200 HR chromatographic columns were 5.3, 1.5 and 4.2 respectively, whereas a 4.4 and a greater than 3.9 log10 reduction in HAV in Albumex(R) 5 and 20 respectively were achieved during pasteurization. PMID:9693093

  7. Passive containment cooling system

    DOEpatents

    Conway, Lawrence E.; Stewart, William A.

    1991-01-01

    A containment cooling system utilizes a naturally induced air flow and a gravity flow of water over the containment shell which encloses a reactor core to cool reactor core decay heat in two stages. When core decay heat is greatest, the water and air flow combine to provide adequate evaporative cooling as heat from within the containment is transferred to the water flowing over the same. The water is heated by heat transfer and then evaporated and removed by the air flow. After an initial period of about three to four days when core decay heat is greatest, air flow alone is sufficient to cool the containment.

  8. Effects of differential wall heating in street canyons on dispersion and ventilation characteristics of a passive scalar

    NASA Astrophysics Data System (ADS)

    Cai, Xiaoming

    2012-05-01

    This paper presents the first large-eddy simulation (LES) study of transfer and dispersion of a scalar released from a rough urban facet, either the street surface, the upstream-wall, or the downstream-wall, under the thermo-dynamical conditions of either the upstream-wall or the downstream-wall, plus the roof, heated by solar radiation. The boundary condition of a constant value is adopted for the scalars on the rough urban facets and a wall function is proposed for the scalars. The LES results demonstrate that dispersion inside the street canyon possesses distinctive characteristics for two conditions: the assisting condition in which the thermal-driven flow has the same direction as that of the wind-driven vortex and the opposing condition in which the thermal-driven flow has the opposite direction as that of the wind-driven vortex. For the street-released scalar under the opposing condition, the concentration fluctuations relative to the mean concentration can reach 50% and in general they are much larger than those for the assisting cases which are in the range of 25-30%. The exchange velocity of a scalar between the street canyon air and the urban boundary layer (UBL), wCB(c), is one order of magnitude larger than the exchange velocity between a facet and the urban boundary layer, UBL, w0B(c), indicating quantitatively that the resistance to the transfer of a facet-released scalar is dominated by the near-facet processes. As the temperature difference between the wall and the UBL, ΔT, increases, the total resistance to street canyon ventilation becomes more dominated by the near-facet resistance. The assisting conditions are favourable to ventilating the scalars from both walls, whereas the opposing conditions are only favourable to the ventilation of the downstream-wall released scalar. In the range of ΔT tested in this study, the exchange velocity, wCB(c), linearly increases with ΔT and can be well parameterised. For the assisting cases, the advective

  9. Safety significance of ATR (Advanced Test Reactor) passive safety response attributes

    SciTech Connect

    Atkinson, S.A.

    1989-01-01

    The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety posture of the facility. The three passive safety attributes being evaluated in the paper are: (1) In-core and in-vessel natural convection cooling, (2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and (3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond for most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) model ands results were used to evaluate the significance to ATR fuel damage frequency (or probability) of the above three passive response attributes. The results of the evaluation indicate that the first attribute is a major safety characteristic of the ATR. The second attribute has a noticeable but only minor safety significance. The third attribute has no significant influence on the ATR Level 1 PRA because of the diversity and redundancy of the ATR firewater injection system (emergency coolant system). 8 refs., 4 figs., 1 tab.

  10. Passive broadband acoustic thermometry

    NASA Astrophysics Data System (ADS)

    Anosov, A. A.; Belyaev, R. V.; Klin'shov, V. V.; Mansfel'd, A. D.; Subochev, P. V.

    2016-04-01

    The 1D internal (core) temperature profiles for the model object (plasticine) and the human hand are reconstructed using the passive acoustothermometric broadband probing data. Thermal acoustic radiation is detected by a broadband (0.8-3.5 MHz) acoustic radiometer. The temperature distribution is reconstructed using a priori information corresponding to the experimental conditions. The temperature distribution for the heated model object is assumed to be monotonic. For the hand, we assume that the temperature distribution satisfies the heat-conduction equation taking into account the blood flow. The average error of reconstruction determined for plasticine from the results of independent temperature measurements is 0.6 K for a measuring time of 25 s. The reconstructed value of the core temperature of the hand (36°C) generally corresponds to physiological data. The obtained results make it possible to use passive broadband acoustic probing for measuring the core temperatures in medical procedures associated with heating of human organism tissues.

  11. Hood River Passive House

    SciTech Connect

    Hales, D.

    2014-01-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  12. Hood River Passive House

    SciTech Connect

    Hales, David

    2014-01-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  13. A study of the heat-removal process at the semiconductor-ceramics interface in solar cells by the laser thermal-wave method

    NASA Astrophysics Data System (ADS)

    Glazov, A. L.; Kalinovskii, V. S.; Kontrosh, E. V.; Muratikov, K. L.

    2016-06-01

    The influence of the solder layer between a semiconductor solar cell and heat-removing ceramics on the nonstationary heat-transfer processes has been investigated by the laser thermal-wave method. A theoretical model taking into account the presence of additional thermal resistance and thermal capacitance at the soldered junction is proposed. Different soldering modes are considered. It is shown that the laser thermal- wave methods within the developed model allow one to correctly estimate the thermophysical properties of multilayer structures.

  14. Passivated niobium cavities

    DOEpatents

    Myneni, Ganapati Rao; Hjorvarsson, Bjorgvin; Ciovati, Gianluigi

    2006-12-19

    A niobium cavity exhibiting high quality factors at high gradients is provided by treating a niobium cavity through a process comprising: 1) removing surface oxides by plasma etching or a similar process; 2) removing hydrogen or other gases absorbed in the bulk niobium by high temperature treatment of the cavity under ultra high vacuum to achieve hydrogen outgassing; and 3) assuring the long term chemical stability of the niobium cavity by applying a passivating layer of a superconducting material having a superconducting transition temperature higher than niobium thereby reducing losses from electron (cooper pair) scattering in the near surface region of the interior of the niobium cavity. According to a preferred embodiment, the passivating layer comprises niobium nitride (NbN) applied by reactive sputtering.

  15. Assessment of residual heat removal and containment spray pump performance under air and debris ingesting conditions. [PWR

    SciTech Connect

    Kamath, P.S.; Tantillo, T.J.; Swift, W.L.

    1982-09-01

    This report presents an assessment of the performance of Residual Heat Removal (RHR) and Containment Spray (CS) pumps during the recirculation phase of reactor core and containment cooldown following a Loss-of-Coolant Accident (LOCA). The pumped fluid is expected to contain debris such as insulation and may ingest air depending on sump conditions. Findings are based on information collected from the literature and from interviews with pump and seal manufacturers. These findings show that for pumps at normal flow rates operating with sufficient Net Positive Suction Head (NPSH), pump performance degradation is negligible if air ingestion quantities are less than 2% by volume. For air ingestion between 3% and 15% by volume, head degradation depends on individual pump design and operating conditions and for air quantities greater than 15% performance of most pumps will be fully degraded. Also, small quantities of air will increase NPSH requirements for these pumps. For the types and quantities of debris likely to be present in the recirculating fluid, pump performance degradation is expected to be negligible.

  16. Theoretical Design of a Thermosyphon for Efficient Process Heat Removal from Next Generation Nuclear Plant (NGNP) for Production of Hydrogen

    SciTech Connect

    Piyush Sabharwall; Fred Gunnerson; Akira Tokuhiro; Vivek Utgiker; Kevan Weaver; Steven Sherman

    2007-10-01

    The work reported here is the preliminary analysis of two-phase Thermosyphon heat transfer performance with various alkali metals. Thermosyphon is a device for transporting heat from one point to another with quite extraordinary properties. Heat transport occurs via evaporation and condensation, and the heat transport fluid is re-circulated by gravitational force. With this mode of heat transfer, the thermosyphon has the capability to transport heat at high rates over appreciable distances, virtually isothermally and without any requirement for external pumping devices. For process heat, intermediate heat exchangers (IHX) are required to transfer heat from the NGNP to the hydrogen plant in the most efficient way possible. The production of power at higher efficiency using Brayton Cycle, and hydrogen production requires both heat at higher temperatures (up to 1000oC) and high effectiveness compact heat exchangers to transfer heat to either the power or process cycle. The purpose for selecting a compact heat exchanger is to maximize the heat transfer surface area per volume of heat exchanger; this has the benefit of reducing heat exchanger size and heat losses. The IHX design requirements are governed by the allowable temperature drop between the outlet of the NGNP (900oC, based on the current capabilities of NGNP), and the temperatures in the hydrogen production plant. Spiral Heat Exchangers (SHE’s) have superior heat transfer characteristics, and are less susceptible to fouling. Further, heat losses to surroundings are minimized because of its compact configuration. SHEs have never been examined for phase-change heat transfer applications. The research presented provides useful information for thermosyphon design and Spiral Heat Exchanger.

  17. Measurement of convectional heat transfer coefficients in a primary containment vessel with outer pool

    SciTech Connect

    Fukui, Toru; Kataoka, Yoshiyuki; Hatamiya, Shigeo

    1990-01-01

    New concepts with passive safety systems that use no active compounds, such as pumps, have been recently developed for next-generation nuclear power plants. In these concepts, several ideas and their combination of passive components were adopted for emergency core cooling and residual heat removal systems. For the residual heat removal system, utilization of natural circulation heat transfer in water pools was proposed as a passive containment cooling system (PCCS), which removes decay heat from the primary containment vessel (PCV) during loss-of-coolant accidents (LOCAs). This system consists of a suppression pool (S/P) and an outer pool (O/P), which are set adjacently inside and outside of the steel PCV wall. The core decay heat during LOCA is released through a break as steam and is led into the S/P. The injected steam condenses there, resulting a pool temperature rise. The adsorbed heat in the S/P is transferred to the O/P by convection in both pools and thermal conduction through the steel PCV wall. The heat transferred to the O/P is finally released to the atmosphere by vaporization of the O/P water. Estimation of the convectional heat transfer coefficients in both pools is necessary to predict the heat removal capability in this system precisely. The heat transfer coefficients measured in this study are useful for the design of the next-generation nuclear reactor as the fundamental thermal-hydraulic data in the primary containment vessel with the outer pool.

  18. Surfactants for Bubble Removal against Buoyancy

    NASA Astrophysics Data System (ADS)

    Raza, Md. Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications.

  19. Surfactants for Bubble Removal against Buoyancy.

    PubMed

    Raza, Md Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications. PMID:26743179

  20. Surfactants for Bubble Removal against Buoyancy

    PubMed Central

    Raza, Md. Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications. PMID:26743179

  1. Simulation of decay heat removal by natural convection in a pool type fast reactor model-ramona-with coupled 1D/2D thermal hydraulic code system

    SciTech Connect

    Kasinathan, N.; Rajakumar, A.; Vaidyanathan, G.; Chetal, S.C.

    1995-09-01

    Post shutdown decay heat removal is an important safety requirement in any nuclear system. In order to improve the reliability of this function, Liquid metal (sodium) cooled fast breeder reactors (LMFBR) are equipped with redundant hot pool dipped immersion coolers connected to natural draught air cooled heat exchangers through intermediate sodium circuits. During decay heat removal, flow through the core, immersion cooler primary side and in the intermediate sodium circuits are also through natural convection. In order to establish the viability and validate computer codes used in making predictions, a 1:20 scale experimental model called RAMONA with water as coolant has been built and experimental simulation of decay heat removal situation has been performed at KfK Karlsruhe. Results of two such experiments have been compiled and published as benchmarks. This paper brings out the results of the numerical simulation of one of the benchmark case through a 1D/2D coupled code system, DHDYN-1D/THYC-2D and the salient features of the comparisons. Brief description of the formulations of the codes are also included.

  2. Passivation of the La2NiMnO6 double perovskite to hydroxylation by excess nickel, and the fate of the hydroxylated surface upon heating

    NASA Astrophysics Data System (ADS)

    Fulmer, Adam T.; Dondlinger, Jasmine; Langell, Marjorie A.

    2014-06-01

    The double perovskites with a total elemental content of LaNi0.5Mn0.5O3 and LaNi0.75Mn0.25O3 were synthesized by solid state methods, although the LaNi0.75Mn0.25O3 material underwent phase separation into NiO, LaNiO3 and LaNi0.5Mn0.5O3. Auger Electron Spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS) indicated substantial lanthanum surface segregation for the LaNi0.5Mn0.5O3 material, which formed an altered La(OH)3 layer 50-100 monolayers in thickness. The La(OH)3 could be removed by Ar+ sputtering to achieve a surface of approximately stoichiometric concentration. Heating the La(OH)3-covered LaNi0.5Mn0.5O3 did not regenerate the double perovskite but rather produced an overlayer of La2O3. While the LaNi0.75Mn0.25O3 material displayed extensive phase separation, the excess nickel appeared to prevent substantial lanthanum surface segregation.

  3. Passive Accelerometer

    NASA Technical Reports Server (NTRS)

    Naumann, Robert J.; Baugher, Charles; Alexander, Iwan

    1992-01-01

    Motion of ball in liquid indicates acceleration. Passive accelerometer measures small accelerations along cylindrical axis. Principle of operation based on Stokes' law. Provides accurate measurements of small quasi-steady accelerations. Additional advantage, automatically integrates out unwanted higher-frequency components of acceleration.

  4. Multiple pollutant removal using the condensing heat exchanger: Phase 1 final report, November 1995--June 1997. Addendum 2: Task 3 topical report -- Long term wear test

    SciTech Connect

    Kudlac, G.A.

    1998-06-01

    Long-term operation of a condensing heat exchanger under typical coal-fired flue gas conditions was investigated in Phase 1, Task 3 of the Multiple Pollutant Removal Using the Condensing Heat Exchanger test program. The specific goal of this task was to determine the amount of wear, if any, on the Teflon{reg_sign}-covered heat transfer tubes in a condensing heat exchanger. A pilot-scale single-stage condensing heat exchanger (CHX{reg_sign}) was operated under typical coal-fired flue gas conditions on a continuous basis for a period of approximately 10 months. Operating conditions and particulate loadings for the test unit were monitored, Teflon{reg_sign} film thickness measurements were conducted, and surface replications (which duplicate the surface finish at the microscopic level) were taken at various times during the test. Data from the test indicate that virtually no decrease in Teflon{reg_sign} thickness was observed for the coating on the first two rows of heat exchanger tubes, even at high inlet particulate loadings (400 mg/dscm [0.35 lb/10{sup 6} Btu]). Evidence of wear was present only at the microscopic level, and even then was very minor in severity. Operation at high inlet particulate loadings resulted in accumulated ash deposits within the heat exchanger. Installation of a modified (higher flow rate) wash nozzle manifold substantially reduced subsequent deposit formation.

  5. Preservation of FFTF Data Related to Passive Safety Testing

    SciTech Connect

    Wootan, David W.; Butner, R. Scott; Omberg, Ronald P.; Makenas, Bruce J.; Nielsen, Deborah L.

    2010-10-01

    One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980’s. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: 1) to verify natural circulation as a reliable means to safely remove decay heat, 2) to extend passive safety

  6. Gas-Cooled Fast Breeder Reactor Preliminary Safety Information Document, Amendment 10. GCFR residual heat removal system criteria, design, and performance

    SciTech Connect

    Not Available

    1980-09-01

    This report presents a comprehensive set of safety design bases to support the conceptual design of the gas-cooled fast breeder reactor (GCFR) residual heat removal (RHR) systems. The report is structured to enable the Nuclear Regulatory Commission (NRC) to review and comment in the licensability of these design bases. This report also presents information concerning a specific plant design and its performance as an auxiliary part to assist the NRC in evaluating the safety design bases.

  7. Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1995-01-01

    A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo's structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated.

  8. Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability

    DOEpatents

    Hunsbedt, A.; Boardman, C.E.

    1995-04-11

    A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor is disclosed. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo`s structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated. 5 figures.

  9. Evaluation of catalyzed and electrically heated filters for removal of particulate emissions from diesel-A- and JP-8-fueled engines.

    PubMed

    Kelly, Kerry E; Wagner, David A; Lighty, JoAnn S; Sarofim, Adel F; Bretecher, Brad; Holden, Bruce; Helgeson, Norm; Sahay, Keshav; Nardi, Zack

    2004-01-01

    In-service diesel engines are a significant source of particulate matter (PM) emissions, and they have been subjected to increasingly strict emissions standards. Consequently, the wide-scale use of some type of particulate filter is expected. This study evaluated the effect of an Engelhard catalyzed soot filter (CSF) and a Rypos electrically heated soot filter on the emissions from in-service diesel engines in terms of PM mass, black carbon concentration, particle-bound polycyclic aromatic hydrocarbon concentration, and size distribution. Both filters capture PM. The CSF relies on the engine's exhaust to reach the catalyst regeneration temperature and oxidize soot, whereas the electrically heated filter contains a heating element to oxidize soot. The filters were installed on several military diesel engines. Particle concentrations and compositions were measured before and after installation of the filter and again after several months of operation. Generally, the CSF removed at least 90% of total PM, and the removal efficiency improved or remained constant after several months of operation. In contrast, the electrical filters removed 44-69% of PM mass. In addition to evaluating the soot filters, the sampling team also compared the results of several real-time particle measurement instruments to traditional filter measurements of total mass. PMID:14871016

  10. Heat generated by Er:YAG laser in the pulp chamber of teeth submitted to removal of dental tissue and composite resin

    NASA Astrophysics Data System (ADS)

    Zanin, Fatima; Brugnera, Aldo, Jr.; Pecora, Jesus D.; Pinheiro, Antonio; Spano, Julio; Barbin, Eduardo; Marchesan, Melissa A.

    2004-05-01

    The knowledge about and control of thermal energy produced by Er:YAG laser after irradiating hard dental tissues and compound resin is important because the pulp, like all vital biological tissue, has a certain capacity for supporting stimulus. The objective of this study was to analyze the thermal variation generated by Er:YAG laser (λ=2.94μm) during the preparation of a Class I cavity in the dental structure and in the removal of microhybrid Z100 (3M) compound resin. An evaluation was made of 30 maxillary human pre-molar teeth from the bank of the Endodontic Laboratory Center of Ribeirao Preto Dental School, Brasil. The sample was divided into 6 groups of 5 teeth each: Group 1, preparation of Class I cavity with Er:YAG laser (350mJ, 3Hz, 343 impulses, 120J, 113 seconds); Group 2, preparation of Class I cavity with Er:YAG laser (350mJ, 4Hz, 343 impulses, 120J, 81 seconds); Group 3, preparation of Class I cavity with Er:YAG laser (350mJ, 6Hz, 343 impulses, 120J, 58 seconds); Group 4, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 3Hz, 258 impulses, 90J, 85 seconds); Group 5, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 4Hz, 258 impulses, 90J, 67 seconds); Group 6, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 6Hz, 258 impulses, 42 seconds). The laser used was KaVo Key 2 (Biberach, Germany), λ=2,94μm, P=3 Watts, pulse duration of 250μs, with air-water cooling. The increase in temperature during dental preparation and the removal of the compound resin was evaluated by means of a Tektronix DMM916 Thermocouple (Consitec, Brasil). The results showed that the application of laser for the removal of the hard dental tissues and for the removal of compound resins with the pulse frequencies 3, 4 and 6 Hz did not generate heating greater than 3.1°C and remained within the histopathological limits permitted for pulp tissue (5.5°C) and there was a significant statistical

  11. Hybrid heat capacity-moving slab solid-state laser

    DOEpatents

    Stappaerts, Eddy A.

    2005-03-01

    Laser material is pumped and its stored energy is extracted in a heat capacity laser mode at a high duty factor. When the laser material reaches a maximum temperature, it is removed from the lasing region and a subsequent volume of laser material is positioned into the lasing region to repeat the lasing process. The heated laser material is cooled passively or actively outside the lasing region.

  12. Natural Circulation in the Blanket Heat Removal System During a Loss-of-Pumping Accident (LOFA) Based on Initial Conceptual Design

    SciTech Connect

    Hamm, L.L.

    1998-10-07

    A transient natural convection model of the APT blanket primary heat removal (HR) system was developed to demonstrate that the blanket could be cooled for a sufficient period of time for long term cooling to be established following a loss-of-flow accident (LOFA). The particular case of interest in this report is a complete loss-of-pumping accident. For the accident scenario in which pumps are lost in both the target and blanket HR systems, natural convection provides effective cooling of the blanket for approximately 68 hours, and, if only the blanket HR systems are involved, natural convection is effective for approximately 210 hours. The heat sink for both of these accident scenarios is the assumed stagnant fluid and metal on the secondary sides of the heat exchangers.

  13. Studies of Forced-Convection Heat Transfer Augmentation in Large Containment Enclosures

    SciTech Connect

    Kuhn, S.Z.; Peterson, P.F.

    2001-06-17

    Heat transfer enhancement due to jet mixing inside a cylindrical enclosure is discussed. This work addresses conservative heat transfer assumptions regarding mixing and condensation that have typically been incorporated into passive containment design analyses. This research presents the possibility for increasing decay heat removal of passive containment systems under combined natural and forced convection. Eliminating these conservative assumptions could result in a changed containment design and reduce the construction cost. It is found that the ratio of forced- and free-convection Nusselt numbers can be predicted as a function of the Archimedes number and a correlated factor accounting for jet orientation and enclosure geometry.

  14. Passive solar technology aids biogas digesters

    SciTech Connect

    Not Available

    1988-07-01

    Farming communities throughout China rely on biogas generators as a primary source of light and heat, as well as using the sludge as a nitrogen-rich fertilizer. Now researchers at Beijing's Solar Energy Laboratory have improved efficiency by building a rectangular tank out of concrete slabs, with one slanted surface painted black and covered with glass. According to a report in New Scientist, this passive solar panel generates heat in the same way as a greenhouse, raising inside temperatures by 10{degree}C and increasing biogas production by 50%. Another advantage of the new tanks is easy access, since the tank's lid sites in wells of water which form a seal against oxygen. (Old biogas tanks were made of soil, sand and a little concrete, prone to developing severe cracks which would allow oxygen to enter thus slowing down anaerobic reaction). Explains Debora MacKenzie of New Scientist: with the new tank, the farmer can simply remove the lid and attack the contents with a spade. This means that the mixture can comprise more than 10% solids. Greater density allows smaller tanks. Rural families need one cubic meter of biogas daily for light and heat; instead of the former 8 cm biogas generator, the new tanks need only be 1 cm. The prediction is that the smaller size could make biogas more popular in China's crowded towns. The biogas department is headed by He Shao Qi, who is also investigating ways to reduce production costs for the tanks.

  15. Burst mode with ps- and fs-pulses: Influence on the removal rate, surface quality, and heat accumulation

    NASA Astrophysics Data System (ADS)

    Neuenschwander, B.; Kramer, Th.; Lauer, B.; Jaeggi, B.

    2015-03-01

    The burst mode for ps and fs pulses for steel and copper is investigated. It is found that the reduction of the energy in a single pulse (in the burst) represents the main factor for the often reported gain in the removal rate using the burst mode e.g. for steel no investigated burst sequence lead to a higher removal rate compared to single pulses at higher repetition rate. But for copper a situation was found where the burst mode leads to a real increase of the removal rate in the range of 20%. Further the burst mode offers the possibility to generate slightly melted flat surfaces with good optical properties in the case of steel. Temperature simulations indicate that the surface state during the burst mode could be responsible for the melting effect or the formation of cavities in clusters which reduces the surface quality.

  16. Tests of a protective shell passive release mechanism for hypersonic wind-tunnel models

    NASA Technical Reports Server (NTRS)

    Puster, R. L.; Dunn, J. E.

    1979-01-01

    A protective shell mechanism for wind tunnel models was developed and tested. The mechanism is passive in operation, reliable, and imposes no new structural design changes for wind tunnel models. Methods of predicting the release time and the measured loads associated with the release of the shell are given. The mechanism was tested in a series of wind tunnel tests to validate the removal process and measure the pressure loads on the model. The protective shell can be used for wind tunnel models that require a step input of heating and loading such as a thin skin heat transfer model. The mechanism may have other potential applications.

  17. Passive solar design handbook. Volume 3: Passive solar design analysis

    NASA Astrophysics Data System (ADS)

    Jones, R. W.; Bascomb, J. D.; Kosiewicz, C. E.; Lazarus, G. S.; McFarland, R. D.; Wray, W. O.

    1982-07-01

    Simple analytical methods concerning the design of passive solar heating systems are presented with an emphasis on the average annual heating energy consumption. Key terminology and methods are reviewed. The solar load ratio (SLR) is defined, and its relationship to analysis methods is reviewed. The annual calculation, or Load Collector Ratio (LCR) method, is outlined. Sensitivity data are discussed. Information is presented on balancing conservation and passive solar strategies in building design. Detailed analysis data are presented for direct gain and sunspace systems, and details of the systems are described. Key design parameters are discussed in terms of their impact on annual heating performance of the building. These are the sensitivity data. The SLR correlations for the respective system types are described. The monthly calculation, or SLR method, based on the SLR correlations, is reviewed. Performance data are given for 9 direct gain systems and 15 water wall and 42 Trombe wall systems.

  18. Effect of Heat-treatment on Quality and Microbiology of Colostrum and on Passive Transfer of Immunoglobulin G in Newborn Calves

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The objective of this study was to describe the effect of heat-treatment on microbial counts and IgG levels in colostrum and describe serum IgG concentrations in newborn calves fed heat-treated vs raw colostrum. Six farms, ranging from 1,200 to 2,500 cows, enrolled in the study. First milking ...

  19. Passive environmental temperature control system

    DOEpatents

    Corliss, John M.; Stickford, George H.

    1981-01-01

    Passive environmental heating and cooling systems are described, which utilize heat pipes to transmit heat to or from a thermal reservoir. In a solar heating system, a heat pipe is utilized to carry heat from a solar heat absorber plate that receives sunlight, through a thermal insulation barrier, to a heat storage wall, with the outer end of the pipe which is in contact with the solar absorber being lower than the inner end. The inclining of the heat pipe assures that the portion of working fluid, such as Freon, which is in a liquid phase will fall by gravity to the outer end of the pipe, thereby assuring diode action that prevents the reverse transfer of heat from the reservoir to the outside on cool nights. In a cooling system, the outer end of the pipe which connects to a heat dissipator, is higher than the inner end that is coupled to a cold reservoir, to allow heat transfer only out of the reservoir to the heat dissipator, and not in the reverse direction.

  20. Gibbs free energy assisted passivation layers

    NASA Astrophysics Data System (ADS)

    Salihoglu, Omer; Tansel, T.; Hostut, M.; Ergun, Y.; Aydinli, A.

    2016-05-01

    Reduction of surface leakage is a major challenge in most photodetectors that requires the elimination of surface oxides on etched mesas during passivation. Engineering the passivation requires close attention to chemical reactions that take place at the interface during the process. In particular, removal of surface oxides may be controlled via Gibbs reactivity. We have compared electrical performance of type-II superlattice photodetectors, designed for MWIR operation, passivated by different passivation techniques. We have used ALD deposited Al2O3, HfO2, TiO2, ZnO, PECVD deposited SiO2, Si3N4 and sulphur containing octadecanethiol (ODT) selfassembled monolayers (SAM) passivation layers on InAs/GaSb p-i-n superlattice photodetectors with cutoff wavelength at 5.1 μm. In this work, we have compared the result of different passivation techniques which are done under same conditions, same epitaxial structure and same fabrication processes. We have found that ALD deposited passivation is directly related to the Gibbs free energy of the passivation material. Gibbs free energies of the passivation layer can directly be compared with native surface oxides to check the effectiveness of the passivation layer before the experimental study.

  1. New England style passive solar

    SciTech Connect

    Kriescher, P.

    2000-06-01

    There are homeowners throughout New England who planned for and built homes that allow them to avoid the sting of winter's high heating bills. These climate-responsive homes rely on passive solar heating, cooling and lighting. An example of such a climate-responsive/passive solar house is the home that Arthur and Terry Becker build on 6 beautiful acres (2.4 hectares) of rolling farm and woodland southeast of Andover, Connecticut, in 1981. They worked very closely with their designer, Al Eggan of K.T. Lear and Associates, to ensure that they would never have to pay for home heating oil, and that they would enjoy a level of year-round comfort that they had not experienced in conventionally built homes.

  2. Portable breathing system. [a breathing apparatus using a rebreathing system of heat exchangers for carbon dioxide removal

    NASA Technical Reports Server (NTRS)

    Lovell, J. S. (Inventor)

    1979-01-01

    A semiclosed-loop rebreathing system is discussed for use in a hostile environment. A packed bed regenerative heat exchanger providing two distinct temperature humidity zones of breathing gas with one zone providing cool, relatively dry air and the second zone providing hot, moist air is described.

  3. Experimental study on the operational and the cooling performance of the APR+ passive auxiliary feedwater system

    SciTech Connect

    Kang, K. H.; Bae, B. U.; Kim, S.; Cho, Y. J.; Park, Y. S.; Kim, B. D.

    2012-07-01

    The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+ which is intended to completely replace the conventional active auxiliary feedwater system. The PAFS cools down the steam generator secondary side and eventually removes the decay heat from the reactor core by introducing a natural driving force mechanism; i.e., condensing steam in nearly-horizontal U-tubes submerged inside the passive condensation cooling tank (PCCT). With an aim of validating the cooling and operational performance of the PAFS, the separate effect test, PASCAL (PAFS Condensing Heat Removal Assessment Loop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in the PAFS. A single nearly-horizontal U-tube whose dimension is same as the prototypic U-tube of the APR+ PAFS is simulated in the PASCAL test. By performing the PASCAL test, the major thermal-hydraulic parameters such as local/overall heat transfer coefficients, fluid temperature inside the tube, wall temperature of the tube, and pool temperature distribution in the PCCT were produced not only to evaluate the current condensation heat transfer model but also to present database for the safety analysis related with the PAFS. (authors)

  4. Passivation of fluorinated activated charcoal

    SciTech Connect

    Del Cul, G.D.; Trowbridge, L.D.; Simmons, D.W.; Williams, D.F.; Toth, L.M.

    1997-10-01

    The Molten Salt Reactor Experiment (MSRE), at the Oak Ridge National Laboratory has been shut down since 1969 when the fuel salt was drained from the core into two Hastelloy N tanks at the reactor site. In 1995, a multiyear project was launched to remediate the potentially hazardous conditions generated by the movement of fissile material and reactive gases from the storage tanks into the piping system and an auxiliary charcoal bed (ACB). The top 12 in. of the ACB is known by gamma scan and thermal analysis to contain about 2.6 kg U-233. According to the laboratory tests, a few feet of fluorinated charcoal are believed to extend beyond the uranium front. The remainder of the ACB should consist of unreacted charcoal. Fluorinated charcoal, when subjected to rapid heating, can decompose generating gaseous products. Under confined conditions, the sudden exothermic decomposition can produce high temperatures and pressures of near-explosive characteristics. Since it will be necessary to drill and tap the ACB to allow installation of piping and instrumentation for remediation and recovery activities, it is necessary to chemically convert the reactive fluorinated charcoal into a more stable material. Ammonia can be administered to the ACB as a volatile denaturing agent that results in the conversion of the C{sub x}F to carbon and ammonium fluoride, NH{sub 4}F. The charcoal laden with NH{sub 4}F can then be heated without risking any sudden decomposition. The only consequence of heating the treated material will be the volatilization of NH{sub 4}F as a mixture of NH{sub 3} and HF, which would primarily recombine as NH{sub 4}F on surfaces below 200 C. The planned scheme for the ACB denaturing is to flow diluted ammonia gas in steps of increasing NH{sub 3} concentration, 2% to 50%, followed by the injection of pure ammonia. This report summarizes the planned passivation treatment scheme to stabilize the ACB and remove the potential hazards. It also includes basic information

  5. Corrosive resistant heat exchanger

    DOEpatents

    Richlen, Scott L.

    1989-01-01

    A corrosive and errosive resistant heat exchanger which recovers heat from a contaminated heat stream. The heat exchanger utilizes a boundary layer of innocuous gas, which is continuously replenished, to protect the heat exchanger surface from the hot contaminated gas. The innocuous gas is conveyed through ducts or perforations in the heat exchanger wall. Heat from the heat stream is transferred by radiation to the heat exchanger wall. Heat is removed from the outer heat exchanger wall by a heat recovery medium.

  6. Efficacy and reusability of alginate-immobilized live and heat-inactivated Trichoderma asperellum cells for Cu (II) removal from aqueous solution.

    PubMed

    Tan, Wei Shang; Ting, Adeline Su Yien

    2012-11-01

    Cu(II) removal efficacies of alginate-immobilized Trichoderma asperellum using viable and non-viable forms were investigated with respect to time, pH, and initial Cu(II) concentrations. The reusability potential of the biomass was determined based on sorption/desorption tests. Cu(II) biosorption by immobilized heat-inactivated T. asperellum cells was the most efficient, with 134.22mg Cu(II) removed g(-1) adsorbent, compared to immobilized viable cells and plain alginate beads (control) with 105.96 and 94.04mg Cu(II) adsorbed g(-1) adsorbent, respectively. Immobilized non-viable cells achieved equilibrium more rapidly within 4h. For all biosorbents, optimum pH for Cu(II) removal was between pH 4 and 5. Reusability of all biosorbents were similar, with more than 90% Cu(II) desorbed with HCl. These alginate-immobilized cells can be applied to reduce clogging and post-separation process incurred from use of suspended biomass. PMID:22940332

  7. Chlorella sorokiniana UTEX 2805, a heat and intense, sunlight-tolerant microalga with potential for removing ammonium from wastewater.

    PubMed

    de-Bashan, Luz E; Trejo, Adan; Huss, Volker A R; Hernandez, Juan-Pablo; Bashan, Yoav

    2008-07-01

    In the summer of 2003, a microalga strain was isolated from a massive green microalgae bloom in wastewater stabilization ponds at the treatment facility of La Paz, B.C.S., Mexico. Prevailing environmental conditions were air temperatures over 40 degrees C, water temperature of 37 degrees C, and insolation of up to 2400 micromol m2 s(-1) at midday for several hours at the water surface for four months. The microalga was identified as Chlorella sorokiniana Shih. et Krauss, based on sequencing its entire 18S rRNA gene. In a controlled photo-bioreactor, this strain can grow to high population densities in synthetic wastewater at temperatures of 40-42 degrees C and light intensity of 2500 micromol m2 s(-1) for 5h daily and efficiently remove ammonium from the wastewater under these conditions better than under normal lower temperature (28 degrees C) and lower light intensity (60 micromol m2 s(-1)). When co-immobilized with the bacterium Azospirillum brasilense that promotes growth of microalgae, the population of microalga grew faster and removed even more ammonium. Under exposure to extreme growth conditions, the quantity of four photosynthetic pigments increased in the co-immobilized cultures. This strain of microalga has potential as a wastewater treatment agent under extreme conditions of temperature and light intensity. PMID:18024023

  8. Experimental study on removal of NO using adsorption of activated carbon/reduction decomposition of microwave heating.

    PubMed

    Shuang-Chen, Ma; Yao, Juan-Juan; Gao, Li

    2012-01-01

    Experimental studies were carried out on flue gas denitrification using activated carbon irradiated by microwave. The effects of microwave irradiation power (reaction temperature), the flow rate of flue gas, the concentration of NO and the flue gas coexisting compositions on the adsorption property of activated carbon and denitrification efficiency were investigated. The results show that: the higher of microwave power, the higher of denitrification efficiency; denitrification efficiency would be greater than 99% and adsorption capacity of NO is relatively stable after seven times regeneration if the microwave power is more than 420 W; adsorption capacity of NO in activated carbon bed is 33.24 mg/g when the space velocity reaches 980 per hour; adsorption capacity declines with increasing of the flow rate of flue gas; the change in denitrification efficiency is not obvious with increasing oxygen content in the flue gas; and the maximum adsorption capacity of NO was observed when moisture in flue gas was about 5.88%. However, the removal efficiency of NO reduces with increasing moisture, and adsorption capacity and removal efficiency of NO reduce with increasing of SO2 concentration in the flue gas. PMID:22988643

  9. Lotus-like effect for metal filings recovery and particle removal on heated metal surfaces using Leidenfrost water droplets.

    PubMed

    Tan, Cher Lin Clara; Sapiha, Kostantyn; Leong, Yoke Fun Hannah; Choi, Siwon; Anariba, Franklin; Thio, Beng Joo Reginald

    2015-07-21

    A "lotus-like" effect is applied to demonstrate the ability of the Leidenfrost water droplets to recover Cu particles on a heated Al substrate. Cu particles on the heated surface adhere to the rim of the Leidenfrost droplets and eventually coat the droplets' surface to form an aggregation. When Fe filings are added to the Cu particles, the aggregated mixture can then be collected using a strong rare earth magnet (NdFeB) upon evaporation of the water. We also show that the Leidenfrost effect can be effectively utilized to recover both hydrophobic (dust and activated carbon) and hydrophilic (SiO2 and MgO) particles from heated Al surfaces without any topographical modification or surfactant addition. Our results show that hydrophobic and hydrophilic materials can be collected with >92% and >96% effectiveness on grooved and smooth Al surfaces, respectively. Furthermore, we observed no significant differences in the amount of material collected above the Leidenfrost point within the tested temperature range (240 °C vs. 340 °C) as well as when the Al sheet was replaced with a Cu sheet as the substrate. However, we did observe that the Leidenfrost droplets were able to collect a greater amount of material when the working liquid was water than when it was ethanol. Our findings show promise in the development of an effective precious coinage metal filings recovery technology for application in the mint industry, as well as the self-cleaning of metallic and semiconductor surfaces where manual cleaning is not amenable. PMID:26053932

  10. Transport Of Passive Scalars In A Turbulent Channel Flow

    NASA Technical Reports Server (NTRS)

    Kim, John; Moin, Parviz

    1990-01-01

    Computer simulation of transport of passive scalars in turbulent channel flow described in report. Shows flow structures and statistical properties. As used here, "passive scalars" means scalar quantities like fluctuations in temperature or concentrations of contaminants that do not disturb flow appreciably. Examples include transport of heat in heat exchangers, gas turbines, and nuclear reactors and dispersal of pollution in atmosphere.

  11. An analysis of loss of decay heat removal trends (1989-1994): Outage risk assessment and management (ORAM) technology. Final report

    SciTech Connect

    Wells, J.

    1995-12-01

    There have been many actions taken by the US nuclear industry to improve reactor safety during shutdown conditions. The purpose of this analysis is to determine if the industry initiatives have been effective at reducing the frequency and severity of reactor coolant system loss of inventory and decay heat removal (DHR) incidents during shutdown, and to determine if there are additional insights based on this analysis that should be shared with the industry to continue to improve performance. Operating experience information from 1989 through 1994 was compiled and analyzed to determine the effectiveness of industry initiatives and to provide additional insights. The results of this analysis show there has been a measurable improvement in the number of incidents, the average severity of incidents, and the frequency of significant incidents. In addition, improvement is noted in the frequency and/or severity of previously identified problem areas. This indicates that industry initiatives have been effective at reducing the frequency of incidents during shutdown conditions.

  12. Thermal-hydraulic simulation of natural convection decay heat removal in the High Flux Isotope Reactor using RELAP5 and TEMPEST: Part 1, Models and simulation results

    SciTech Connect

    Morris, D.G.; Wendel, M.W.; Chen, N.C.J.; Ruggles, A.E.; Cook, D.H.

    1989-01-01

    A study was conducted to examine decay heat removal requirements in the High Flux Isotope Reactor (HFIR) following shutdown from 85 MW. The objective of the study was to determine when forced flow through the core could be terminated without causing the fuel to melt. This question is particularly relevant when a station blackout caused by an external event is considered. Analysis of natural circulation in the core, vessel upper plenum, and reactor pool indicates that 12 h of forced flow will permit a safe shutdown with some margin. However, uncertainties in the analysis preclude conclusive proof that 12 h is sufficient. As a result of the study, two seismically qualified diesel generators were installed in HFIR. 9 refs., 4 figs.

  13. PACTEL experiments for the investigation of passive safety injection systems of advanced light water reactors

    SciTech Connect

    Tuunanen, J.; Munther, R.; Vihavainen, J.

    1996-07-01

    An important aspect of Advanced Light Water Reactors (ALWRs) decay heat removal concerns the plant response under Loss of Coolant Accident (LOCA) conditions. In ALWRs, e.g. Westinghouse AP600, pump driven Emergency Core Cooling Systems (ECCS) are replaced by passive safety injection systems, which are gravity driven. It is therefore important that in such accidents, the ALWR coolant system pressure can be controlled to allow gravity fed injection to take place. The safety issue here is whether undesirable system responses could occur in any circumstances. Additionally, it is necessary to prove that the plant always depressurizes sufficiently for the ECCS to operate efficiently. Two experimental series have been carried out with the PACTEL integral test facility on the simulation of passive safety injection systems of ALWRs in accidental conditions. The safety system investigated was a passive core make-up tank (CMT), which was connected to the downcomer of the test facility. This paper starts with a short description of the PACTEL test facility and a summary of the results of the passive safety injection tests on PACTEL. Also included is a summary of the results of the computer simulations of the tests. The second part of the paper consists of a description of the planned third passive safety injection test series and the results of the pre-test simulations of the planned tests.

  14. Study of optimization of wastewater contaminant removal along with extracellular polymeric substances (EPS) production by a thermotolerant Bacillus sp. ISTVK1 isolated from heat shocked sewage sludge.

    PubMed

    Gupta, Asmita; Thakur, Indu Shekhar

    2016-08-01

    The present work involved study of wastewater contaminant removal along with EPS production by a thermotolerant bacterium Bacillus sp. ISTVK1, isolated from heat shocked sewage sludge. EPS production in basal and mineral medium containing 50% filter sterilized wastewater and 0.5% sucrose was found to be 0.83±0.12gL(-1) and 0.31±0.10gL(-1) culture, respectively. GC-MS analysis of EPS revealed the presence of β-d-glucose, α-d-galactose and β-d-arabinose. FT-IR spectrum confirmed the presence carbohydrates. Box-Behnken design was used to optimize process parameters for enhanced EPS production along with % COD reduction of wastewater. The optimised conditions when used in a 1.5L bioreactor showed EPS production of 1.67±0.06gL(-1) culture and 93.0±0.21 % COD removal. PMID:26906445

  15. Fundamental studies of passivity and passivity breakdown

    SciTech Connect

    Macdonald, D.D.; Urquidi-Macdonald, M.; Song, H.; Biaggio-Rocha, S.; Searson, P.

    1991-11-01

    This report summarizes the findings of our fundamental research program on passivity and passivity breakdown. During the past three and one half years in this program (including the three year incrementally-funded grant prior to the present grant), we developed and experimentally tested various physical models for the growth and breakdown of passive films on metal surfaces. These models belong to a general class termed point defects models'' (PDMs), in which the growth and breakdown of passive films are described in terms of the movement of anion and cation vacancies.

  16. Bismuth Passivation Technique for High-Resolution X-Ray Detectors

    NASA Technical Reports Server (NTRS)

    Chervenak, James; Hess, Larry

    2013-01-01

    The Athena-plus team requires X-ray sensors with energy resolution of better than one part in 3,000 at 6 keV X-rays. While bismuth is an excellent material for high X-ray stopping power and low heat capacity (for large signal when an X-ray is stopped by the absorber), oxidation of the bismuth surface can lead to electron traps and other effects that degrade the energy resolution. Bismuth oxide reduction and nitride passivation techniques analogous to those used in indium passivation are being applied in a new technique. The technique will enable improved energy resolution and resistance to aging in bismuth-absorber-coupled X-ray sensors. Elemental bismuth is lithographically integrated into X-ray detector circuits. It encounters several steps where the Bi oxidizes. The technology discussed here will remove oxide from the surface of the Bi and replace it with nitridized surface. Removal of the native oxide and passivating to prevent the growth of the oxide will improve detector performance and insulate the detector against future degradation from oxide growth. Placing the Bi coated sensor in a vacuum system, a reduction chemistry in a plasma (nitrogen/hydrogen (N2/H2) + argon) is used to remove the oxide and promote nitridization of the cleaned Bi surface. Once passivated, the Bi will perform as a better X-ray thermalizer since energy will not be trapped in the bismuth oxides on the surface. A simple additional step, which can be added at various stages of the current fabrication process, can then be applied to encapsulate the Bi film. After plasma passivation, the Bi can be capped with a non-diffusive layer of metal or dielectric. A non-superconducting layer is required such as tungsten or tungsten nitride (WNx).

  17. Heated scallop-shell powder treatment for deactivation and removal of Listeria sp. biofilm formed at a low temperature.

    PubMed

    Shimamura, Nobumitsu; Irie, Fumio; Yamakawa, Takahiro; Kikuchi, Mikio; Sawai, Jun

    2015-01-01

    The ability of heated scallop-shell powder (HSSP) to work against Listeria sp. biofilm formed at a low temperature was investigated. A biofilm of L. innocua ATCC 33090 was grown on a glass plate at 15˚C for 15 days, then immersed in HSSP slurry. Following treatment, the disinfection ability of the HSSP against the biofilm was non-destructively quantified by conductimetric assay. The biofilm grown at 15˚C was less sensitive than that grown at 37˚C to HSSP treatment and alkaline treatment. The biofilm grown at 15˚C was completely deactivated by 30 min of HSSP treatment (10 mg/mL, pH 12.5). In contrast, after 30 min treatment with alkaline solution at pH 12.5 or sodium hypochlorite (100 ppm), the activity was reduced by only one order of magnitude. The disinfection efficacy of HSSP (10 mg/mL) against L. innocua is similar to or higher than that of sodium hypochlorite (200 ppm). Fluorescence microscopy validated the results of the conductimetric assay. Therefore, HSSP treatment is a potentially powerful alternative control agent against Listeria sp. biofilms that present hazards in the food industry. PMID:26133513

  18. AC losses and heat removal in three-dimensional winding pack of Samsung superconducting test facility under pulsed magnetic field operation

    NASA Astrophysics Data System (ADS)

    Wang, Qiuliang; Seong Yoon, Cheon; Baang, Sungkeun; Kim, Myungkyu; Park, Hyunki; Kim, Yongjin; Lee, Sangil; Kim, Keeman

    2001-04-01

    The Samsung superconducting test facility (SSTF) will be operated under the highly pulsed field to simulate the operating conditions of KSTAR. An analysis has been performed to study the transient heat removal characteristics and temperature margin for the main, blip and compensating coils in the SSTF. This method is based on a quasi-three-dimensional model, which the thermal coupling of turn-to-turn, pancake-to-pancake and channel-to-channel is taken into account, to simulate the conductor temperature rise and the thermal expansion of supercritical helium due to the high AC losses under the pulsed field. The local AC losses, which include coupling loss, eddy current loss and hysteresis loss in the cable-in-conduit conductor, are estimated. The temperature margin, mass flow rate, distribution of AC losses are studied under the given operating scenario. The mass flow reduction and peak temperature rise depending on the inlet pressure and inlet position of CICC are studied. It is shown that the initial mass flow rate remarkably influences on the peak temperature of superconducting strands. The large mass flow rate can reduce the temperature rise when the inlet of helium is located at the high field region. By contrast, because of heat induced flow to improve the cooling condition of the superconducting strands, the small initial mass flow rate results in the low peak temperature in strands when the inlet of helium is located at the low field region.

  19. Enceladus' Enigmatic Heat Flow

    NASA Astrophysics Data System (ADS)

    Howett, C.; Spencer, J. R.; Spencer, D.; Verbiscer, A.; Hurford, T.; Segura, M.

    2013-12-01

    Accurate knowledge of Enceladus' heat flow is important because it provides a vital constraint on Enceladus' tidal dissipation mechanisms, orbital evolution, and the physical processes that generate the plumes. In 2011 we published an estimate of the current heat flow from Enceladus' active south polar terrain: 15.8 +/- 3.1 GW (Howett et al., 2011). This value was calculated by first estimating by modeling, and then removing, the passive component from 17 to 1000 micron observations made of the entire south polar terrain by Cassini's Composite Infrared Spectrometer (CIRS). The heat flow was then directly calculated from the residual, assumed endogenic, component. The derived heat flow of 15.8 GW was surprisingly high, about 10 times greater than that predicted by steady-state tidal heating (Meyer and Wisdom, 2007). CIRS has also returned high spatial resolution observations of Enceladus' active south polar terrain. Two separate observations are used: 9 to 16 micron observations taken over nearly the complete south polar terrain and a single 17 to 1000 micron scan over Damascus, Baghdad and Cairo. The shorter wavelength observations are only sensitive to high temperature emission (>70 K), and so longer wavelength observations are required (despite their limited spatial coverage) to estimate the low temperature emission from the stripes. Analysis of these higher resolution observations tells a different story of Enceladus' endogenic heat flow: the preliminary estimate of the heat flow from the active tiger stripes using these observations is 4.2 GW. An additional 0.5 GW must be added to this number to account for the latent heat release by the plumes (Ingersoll and Pankine 2009), giving a total preliminary estimate of 4.9 GW. The discrepancy in these two numbers is significant and we are currently investigating the cause. One possible reason is that there is significantly higher endogenic emission from the regions between the tiger stripes than we currently estimate

  20. Fundamental studies on passivity and passivity breakdown

    SciTech Connect

    Macdonald, D.D.; Urquidi-Macdonald, M.

    1993-06-01

    Using photoelectrochemical impedance and admittance spectroscopies, a fundamental and quantitative understanding of the mechanisms for the growth and breakdown of passive films on metal and alloy surfaces in contact with aqueous environments is being developed. A point defect model has been extended to explain the breakdown of passive films, leading to pitting and crack growth and thus development of damage due to localized corrosion.

  1. Passive-solar greenhouse

    SciTech Connect

    Not Available

    1982-01-01

    Our project objective was to design, construct, and operate a commercialized (16' x 50') passive, solar greenhouse. The structure was originally intended as a vegetable forcing facility to produce vegetable crops in the off-season. Building and size constraints and economic considerations convinced us to use the greenhouse for producing bedding plants and vegetable starts in the spring, high value vegetables (tomatoes, cucumbers) in the fall and forced bulbs in the winter. This crop sequence allows us to use the greenhouse all year without additional heat as the crops are adopted to the temperature regime of the greenhouse during each particular season. In our first season, the greenhouse performed beautifully. The lowest temperature recorded was 38/sup 0/F after 4 cold, cloudy days in February. The production of bedding plants has allowed us to diversify our products and the early transplants we produced were a great asset to our vegetable farming operation. Although construction cost (4.57 sq. ft.) is higher than that of a conventional polyethylene-covered, quonset-type greenhouse (approx. $1.92 sq. ft.), our annual operating cost is cheaper than that of a conventional greenhouse (0.49 cents sq. ft. versus 0.67 cents sq. ft.) due to a longer usable lifetime of the structure and the elimination of heating costs. Our structure has been toured by interested individuals, school and farm groups. We plan to publicize the structure and its advantages by promoting more visits to the site.

  2. Passive cooling system for a vehicle

    DOEpatents

    Hendricks, Terry Joseph; Thoensen, Thomas

    2005-11-15

    A passive cooling system for a vehicle (114) transfers heat from an overheated internal component, for example, an instrument panel (100), to an external portion (116) of the vehicle (114), for example, a side body panel (126). The passive cooling system includes one or more heat pipes (112) having an evaporator section (118) embedded in the overheated internal component and a condenser section (120) at the external portion (116) of the vehicle (114). The evaporator (118) and condenser (120) sections are in fluid communication. The passive cooling system may also include a thermally conductive film (140) for thermally connecting the evaporator sections (118) of the heat pipes (112) to each other and to the instrument panel (100).

  3. Passive Cooling System for a Vehicle

    DOEpatents

    Hendricks, T. J.; Thoensen, T.

    2005-11-15

    A passive cooling system for a vehicle (114) transfers heat from an overheated internal component, for example, an instrument panel (100), to an external portion (116) of the vehicle (114), for example, a side body panel (126). The passive cooling system includes one or more heat pipes (112) having an evaporator section (118) embedded in the overheated internal component and a condenser section (120) at the external portion (116) of the vehicle (114). The evaporator (118) and condenser (120) sections are in fluid communication. The passive cooling system may also include a thermally conductive film (140) for thermally connecting the evaporator sections (118) of the heat pipes (112) to each other and to the instrument panel (100).

  4. Tropospheric Passive Remote Sensing

    NASA Technical Reports Server (NTRS)

    Keafer, L. S., Jr. (Editor)

    1982-01-01

    The long term role of airborne/spaceborne passive remote sensing systems for tropospheric air quality research and the identification of technology advances required to improve the performance of passive remote sensing systems were discussed.

  5. Passive storage technologies

    NASA Astrophysics Data System (ADS)

    Kittel, P.

    1984-04-01

    Advances in storage technology and how passive techniques could be applied to the storage of propellants at the space station are described. The devices considered are passive orbital disconnect struts, cooled shield optimization, liftweight shields and catalytic converters.

  6. Passive storage technologies

    NASA Technical Reports Server (NTRS)

    Kittel, P.

    1984-01-01

    Advances in storage technology and how passive techniques could be applied to the storage of propellants at the space station are described. The devices considered are passive orbital disconnect struts, cooled shield optimization, liftweight shields and catalytic converters.

  7. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    SciTech Connect

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.

    1995-09-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba`s Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to {plus_minus}5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes.

  8. Interlanguage Passive Construction

    ERIC Educational Resources Information Center

    Simargool, Nirada

    2008-01-01

    Because the appearance of the passive construction varies cross linguistically, differences exist in the interlanguage (IL) passives attempted by learners of English. One such difference is the widely studied IL pseudo passive, as in "*new cars must keep inside" produced by Chinese speakers. The belief that this is a reflection of L1 language…

  9. Passively Q-switched side pumped monolithic ring laser

    NASA Technical Reports Server (NTRS)

    Li, Steven X. (Inventor)

    2012-01-01

    Disclosed herein are systems and methods for generating a side-pumped passively Q-switched non-planar ring oscillator. The method introduces a laser into a cavity of a crystal, the cavity having a round-trip path formed by a reflection at a dielectrically coated front surface, a first internal reflection at a first side surface of the crystal at a non-orthogonal angle with the front, a second internal reflection at a top surface of the crystal, and a third internal reflection at a second side surface of the crystal at a non-orthogonal angle with the front. The method side pumps the laser at the top or bottom surface with a side pump diode array beam and generates an output laser emanating at a location on the front surface. The design can include additional internal reflections to increase interaction with the side pump. Waste heat may be removed by mounting the crystal to a heatsink.

  10. PCM Passive Cooling System Containing Active Subsystems

    NASA Technical Reports Server (NTRS)

    Blanding, David E.; Bass, David I.

    2005-01-01

    A multistage system has been proposed for cooling a circulating fluid that is subject to intermittent intense heating. The system would be both flexible and redundant in that it could operate in a basic passive mode, either sequentially or simultaneously with operation of a first, active cooling subsystem, and either sequentially or simultaneously with a second cooling subsystem that could be active, passive, or a combination of both. This flexibility and redundancy, in combination with the passive nature of at least one of the modes of operation, would make the system more reliable, relative to a conventional cooling system. The system would include a tube-in-shell heat exchanger, within which the space between the tubes would be filled with a phase-change material (PCM). The circulating hot fluid would flow along the tubes in the heat exchanger. In the basic passive mode of operation, heat would be conducted from the hot fluid into the PCM, wherein the heat would be stored temporarily by virtue of the phase change.

  11. A self-consistent view on plasma-neutral interaction near a wall: plasma acceleration by momentum removal and heating by cold walls

    NASA Astrophysics Data System (ADS)

    van Rooij, Gerard; den Harder, Niek; Minea, Teofil; Shumack, Amy; de Blank, H.; Plasma Physics Team

    2014-10-01

    In plasma physics, material walls are generally regarded as perfect sinks for charged particles and their energy. A special case arises when the wall efficiently reflects the neutralized plasma particles (with a significant portion of their kinetic energy) and at the same time the upstream plasma is of sufficiently high density to yield strong neutral-ion coupling (i.e. reflected energy and momentum will not escape from the plasma). Under these conditions, plasma-surface interaction will feedback to the upstream plasma and a self-consistent view on the coupling between plasma and neutrals is required for correct prediction of plasma conditions and plasma-surface interaction. Here, an analytical and numerical study of the fluid equations is combined with experiments (in hydrogen and argon) to construct such a self-consistent view. It shows how plasma momentum removal builds up upstream pressure and causes plasma acceleration towards the wall. It also shows how energy reflection causes plasma heating, which recycles part of the reflected power to the wall and induces additional flow acceleration due to local sound speed increase. The findings are relevant as generic textbook example and are at play in the boundary plasma of fusion devices.

  12. Validation of the integration of CFD and SAS4A/SASSYS-1: Analysis of EBR-II shutdown heat removal test 17

    SciTech Connect

    Thomas, J. W.; Fanning, T. H.; Vilim, R.; Briggs, L. L.

    2012-07-01

    Recent analyses have demonstrated the need to model multidimensional phenomena, particularly thermal stratification in outlet plena, during safety analyses of loss-of-flow transients of certain liquid-metal cooled reactor designs. Therefore, Argonne's reactor systems safety code SAS4A/SASSYS-1 is being enhanced by integrating 3D computational fluid dynamics models of the plena. A validation exercise of the new tool is being performed by analyzing the protected loss-of-flow event demonstrated by the EBR-II Shutdown Heat Removal Test 17. In this analysis, the behavior of the coolant in the cold pool is modeled using the CFD code STAR-CCM+, while the remainder of the cooling system and the reactor core are modeled with SAS4A/SASSYS-1. This paper summarizes the code integration strategy and provides the predicted 3D temperature and velocity distributions inside the cold pool during SHRT-17. The results of the coupled analysis should be considered preliminary at this stage, as the exercise pointed to the need to improve the CFD model of the cold pool tank. (authors)

  13. Six-phase soil heating for enhanced removal of contaminants: Volatile organic compounds in non-arid soils integrated demonstration, Savannah River Site

    SciTech Connect

    Gauglitz, P.A.; Bergsman, T.M.; Caley, S.M.

    1994-10-01

    In November 1993, Pacific Northwest Laboratory (PNL) and Savannah River Site (SRS) personnel conducted a demonstration of six-phase soil heating (SPSH) at the Savannah River Site (SRS) in Aiken, South Carolina. The demonstration was part of the Volatile Organic Compounds in Non-Arid Soils Integrated Demonstration being conducted near the M-Area operations at the SRS, along a corridor that once contained a process sewer leading to the M-Area seepage basin. In the early 1980s, this sewer line was discovered to be leaking process wastes into the subsurface and contributing to groundwater contamination in the vicinity of M-Area seepage basin. Although use of the sewer line has been discontinued, the slow release of chlorinated solvents such as trichloroethylene (TCE) and perchloroethylene (PCE) from the heterogeneous vadose zone soil continues to be a source of potential groundwater contamination. A significant portion of the VOCs at the demonstration site are retained in low-permeability clay zones. Previous studies have shown that the rate of conventional SVE remediation of the SRS clays is quite slow. The permeability of the clay is of order 10{sup {minus}12} cm{sup 2}, which makes this a particularly difficult interval to remediate. Thus, the challenge for SPSH is to effectively remediate this clay zone by accelerating the removal of TCE and PCE.

  14. Heat pipe methanator

    DOEpatents

    Ranken, William A.; Kemme, Joseph E.

    1976-07-27

    A heat pipe methanator for converting coal gas to methane. Gravity return heat pipes are employed to remove the heat of reaction from the methanation promoting catalyst, transmitting a portion of this heat to an incoming gas pre-heat section and delivering the remainder to a steam generating heat exchanger.

  15. Passive compact molten salt reactor (PCMSR), modular thermal breeder reactor with totally passive safety system

    NASA Astrophysics Data System (ADS)

    Harto, Andang Widi

    2012-06-01

    Design Study Passive Compact Molten Salt Reactor (PCMSR) with totally passive safety system has been performed. The term of Compact in the PCMSR name means that the reactor system is designed to have relatively small volume per unit power output by using modular and integral concept. In term of modular, the reactor system consists of three modules, i.e. reactor module, turbine module and fuel management module. The reactor module is an integral design that consists of reactor, primary and intermediate heat exchangers and passive post shutdown cooling system. The turbine module is an integral design of a multi heating, multi cooling, regenerative gas turbine. The fuel management module consists of all equipments related to fuel preparation, fuel reprocessing and radioactive handling. The preliminary calculations show that the PCMSR has negative temperature and void reactivity coefficient, passive shutdown characteristic related to fuel pump failure and possibility of using natural circulation for post shutdown cooling system.

  16. Passive compact molten salt reactor (PCMSR), modular thermal breeder reactor with totally passive safety system

    SciTech Connect

    Harto, Andang Widi

    2012-06-06

    Design Study Passive Compact Molten Salt Reactor (PCMSR) with totally passive safety system has been performed. The term of Compact in the PCMSR name means that the reactor system is designed to have relatively small volume per unit power output by using modular and integral concept. In term of modular, the reactor system consists of three modules, i.e. reactor module, turbine module and fuel management module. The reactor module is an integral design that consists of reactor, primary and intermediate heat exchangers and passive post shutdown cooling system. The turbine module is an integral design of a multi heating, multi cooling, regenerative gas turbine. The fuel management module consists of all equipments related to fuel preparation, fuel reprocessing and radioactive handling. The preliminary calculations show that the PCMSR has negative temperature and void reactivity coefficient, passive shutdown characteristic related to fuel pump failure and possibility of using natural circulation for post shutdown cooling system.

  17. Heat collector

    DOEpatents

    Merrigan, M.A.

    1981-06-29

    A heat collector and method suitable for efficiently and cheaply collecting solar and other thermal energy are provided. The collector employs a heat pipe in a gravity-assist mode and is not evacuated. The collector has many advantages, some of which include ease of assembly, reduced structural stresses on the heat pipe enclosure, and a low total materials cost requirement. Natural convective forces drive the collector, which after startup operates entirely passively due in part to differences in molecular weights of gaseous components within the collector.

  18. Heat collector

    DOEpatents

    Merrigan, Michael A.

    1984-01-01

    A heat collector and method suitable for efficiently and cheaply collecting solar and other thermal energy are provided. The collector employs a heat pipe in a gravity-assist mode and is not evacuated. The collector has many advantages, some of which include ease of assembly, reduced structural stresses on the heat pipe enclosure, and a low total materials cost requirement. Natural convective forces drive the collector, which after startup operates entirely passively due in part to differences in molecular weights of gaseous components within the collector.

  19. HEAT EXCHANGER

    DOEpatents

    Fox, T.H. III; Richey, T. Jr.; Winders, G.R.

    1962-10-23

    A heat exchanger is designed for use in the transfer of heat between a radioactive fiuid and a non-radioactive fiuid. The exchanger employs a removable section containing the non-hazardous fluid extending into the section designed to contain the radioactive fluid. The removable section is provided with a construction to cancel out thermal stresses. The stationary section is pressurized to prevent leakage of the radioactive fiuid and to maintain a safe, desirable level for this fiuid. (AEC)

  20. New PANDA Tests to Investigate Effects of Light Gases on Passive Safety Systems

    SciTech Connect

    Paladino, D.; Auban, O.; Candreia, P.; Huggenberger, M.; Strassberger, H.J.

    2002-07-01

    The large- scale thermal-hydraulic PANDA facility (located at PSI in Switzerland), has been used over the last few years for investigating different passive decay- heat removal systems and containment phenomena for the next generation of light water reactors (Simplified Boiling Water Reactor: SBWR; European Simplified Boiling Water Reactor: ESBWR; Siedewasserreaktor: SWR-1000). Currently, as part of the European Commission 5. EURATOM Framework Programme project 'Testing and Enhanced Modelling of Passive Evolutionary Systems Technology for Containment Cooling' (TEMPEST), a new series of tests is being planned in the PANDA facility to experimentally investigate the distribution of non-condensable gases inside the containment and their effect on the performance of the 'Passive Containment Cooling System' (PCCS). Hydrogen release caused by the metal-water reaction in the case of a postulated severe accident will be simulated in PANDA by injecting helium into the reactor pressure vessel. In order to provide suitable data for Computational Fluid Dynamic (CFD) code assessment and improvement, the instrumentation in PANDA has been upgraded for the new tests. In the present paper, a detailed discussion is given of the new PANDA tests to be performed to investigate the effects of light gas on passive safety systems. The tests are scheduled for the first half of the year 2002. (authors)

  1. Passively cooled diode laser for high-power applications

    NASA Astrophysics Data System (ADS)

    Bonati, Guido F.; Hennig, Petra; Schmidt, Karsten

    2004-06-01

    For the usage of diode lasers in industrial applications, customers ask today for expected lifetimes of more then 30.000 hours. To match the request for low costs per Watt as well, the output power has to be as high as possible. To achieve a maximum power out of a diode laser bar, heat removal must be extremely efficient. Today, micro channel heatsinks (MCHS) are the only way to achieve the high power level of 50W. But due to erosion/corrosion effects the lifetime of MCHS is limited at 15000...20.000 hours today. Finally we have to determine that for selected semiconductor materials not the semiconductor but the heatsink is limiting the expected lifetime of high power diode lasers today. Passive heat sinks based on solid copper are not limiting lifetime expectations in any way. But as cooling efficiency is lower, the power has to be reduced to a level of 30...40W. The first time ever, the JENOPTIK Laserdiode can present today a cooling technique that combines the passive cooling of a diode laser bar with the optical output a power of a bar, mounted on a MCHS. Using a special heat exchanger called DCB (patent pending) we were able to increase the power to 50W per bar while looking forward to extend the expected lifetime to more than 30.000 hours for selected materials. Restrictions on the quality of the water by means of deionization grade or PH- level are no longer necessary. The device is operating with regular water. The flow rate is as low as on MCHS, the pressure drop over the DCB is comparable. Additionally, the measurements will show an even lower thermal resistance compared to MCHS. The second generationof engineering samples is built up for pumping rows. A vertical stack design will be available for evaluating purposes soon. All these efforts are part of the JENOPTIK Laserdiode's LongLifeTechnology.

  2. Passive mitigation of mode instabilities

    NASA Astrophysics Data System (ADS)

    Jauregui, C.; Otto, H.-J.; Stutzki, F.; Jansen, F.; Limpert, J.; Tünnermann, A.

    2014-03-01

    The phenomenon of mode instabilities has quickly become the most limiting effect for a further scaling of the average power of fiber laser systems. Consequently it is of great importance to find solutions for this problem. In this work we propose two concrete possible passive mitigation strategies: the first one is based on the reduction of the heat load in the fiber, whereas the second one is based on the reduction of the pump absorption. In both cases a significant increase of the threshold is expected.

  3. Morphological evolution of voids by surface drift diffusion driven by capillary, electromigration, and thermal-stress gradients induced by steady-state heat flow in passivated metallic thin films and flip chip solder joints. I. Theory

    NASA Astrophysics Data System (ADS)

    Ogurtani, Tarik Omer; Akyildiz, Oncu

    2008-07-01

    The morphological evolution of intragranular voids induced by surface drift diffusion under the actions of capillary and electromigration (EM) forces and thermal-stress gradients (TSGs) associated with steady-state heat flow is investigated in passivated metallic thin films and flip chip solder joints via computer simulation using the front-tracking method. In the mesoscopic nonequilibrium thermodynamic formulation of the generalized driving forces for the thermal-stress-induced surface drift diffusion, not only the usual elastic strain energy density contribution but also the elastic dipole tensor interaction (EDTI) between the thermal-stress field and the mobile atomic species (monovacancies) are considered using the concept of elastic interaction energy promoted in unified linear instability analysis (ULISA) [T. O. Ogurtani, Phys. Rev. B 74, 155422 (2006)]. According to extensive computer experiments performed on voids, which are initially cylindrical in shape, two completely different and topographically distinct behaviors are observed during the development of quasistationary state void surface morphologies, even in the presence of strong EM forces. These behaviors strictly depend on whether or not heat flux crowding occurs in the regions between the void surface layer and the sidewalls of the interconnect lines due to proximity effects of the insulating boundaries. In both morphological cases, however, one also observes two well-defined regimes, namely, the EM and TSG dominated regimes in EM versus EDTI parametric space. In the case of the TSG dominated regime, the void center of gravity (centroid) exhibits uniform displacement (drift) velocity proportional and opposite to the induced TSG exactly as predicted by ULISA theory. These domains are bounded by a threshold level curve for the EDTI parameter, above which an extremely sharp crack tip nucleation and propagation occurs in the highly localized minima in the triaxial stress regions (i.e., hot spots

  4. Trends vs. reactor size of passive reactivity shutdown and control performance

    SciTech Connect

    Wade, D.C.; Fujita, E.K.

    1987-01-01

    For LMR concepts, the goal of passive reactivity shutdown has been approached in the US by designing the reactors for favorable relationships among the power, power/flow, and inlet temperature coefficients of reactivity, for high internal conversion ratio (yielding small burnup control swing), and for a primary pump coastdown time appropriately matched to the delayed neutron hold back of power decay upon negative reactivity input. The use of sodium bonded metallic fuel pins has facilitated the achievement of the massive shutdown design goals as a consequence of their high thermal conductivity and high effective heavy metal density. Alternately, core designs based on derated oxide pins may be able to achieve the passive shutdown features at the cost of larger core volume and increased initial fissile inventory. For LMR concepts, the passive decay heat removal goal of inherent safety has been approached in US designs by use of pool layouts, larger surface to volume ratio of the reactor vessel with natural draft air cooling of the vessel surface, elevations and redans which promote natural circulation through the core, and thermal mass of the pool contents sufficient to absorb that initial transient decay heat which exceeds the natural draft air cooling capacity. This paper describes current US ''inherently safe'' reactor design.

  5. Cooling by means of passively grown ice

    SciTech Connect

    Gorski, A.; Schertz, W.; Wantroba, A.; Rush, R.; Falkenberg, J.

    1981-01-01

    A solar cooling technique is described that uses ice passively-grown the previous winter. Using heat pipes (thermal syphons), ice is grown and stored in the same container ready for the coming cooling season. This modern adaption of an old cooling technique may have side application both in this country as well as in more northern regions.

  6. Mennonite Nursing Home passive solar demonstration

    SciTech Connect

    Not Available

    1984-03-01

    A long-term nursing care facility and retirement center was designed for passive solar heating. The system comprises thermal mass, thermal insulation, Trombe walls, and direct gain clerestories. Included here is a topical report, analysis of building performance, owner's perspective, designer's perspective, and summary of information dissemination activities. (MHR)

  7. Passive safety injection system using borated water

    SciTech Connect

    Conway, Lawrence E.; Schulz, Terry L.

    1993-01-01

    A passive safety injection system relies on differences in water density to induce natural circulatory flow patterns which help maintain prescribed concentrations of boric acid in borated water, and prevents boron from accumulating in the reactor vessel and possibly preventing heat transfer.

  8. Instability of flow of liquid film over a heated surface

    SciTech Connect

    Sha, W.T.; Soo, S.L.

    1994-08-01

    Fundamental concepts and basic equations of a flowing thin liquid film cooling a heated surfaced by its vaporization and the effect of dry patches were treated. Stable film flow prior to the appearance of dry patches on the heated surface is maintained by a balance of various forces due to surface tension, shear stress, heat and mass transfer, and gravity. Film splitting at a critical film thickness produces dry patches due to perturbation by waves on a perfect surface, and often by surface imperfection and uneven heating. This work is primarily motivated by the design of next-generation nuclear reactors, which employ many novel passive heat-removal systems via natural circulation. These systems are design to prevent damage to the reactor core and containment without action by the reactor operators during or after a design basis accident such as a loss of coolant accident (LOCA) or a main steam-line break (MSLB) accident.

  9. An investigation of a passively controlled haptic interface

    SciTech Connect

    Davis, J.T.; Book, W.J.

    1997-03-01

    Haptic interfaces enhance cooperation between humans and robotic manipulators by providing force and tactile feedback to the human user during the execution of arbitrary tasks. The use of active actuators in haptic displays presents a certain amount of risk since they are capable of providing unacceptable levels of energy to the systems upon which they operate. An alternative to providing numerous safeguards is to remove the sources of risk altogether. This research investigates the feasibility of trajectory control using passive devices, that is, devices that cannot add energy to the system. Passive actuators are capable only of removing energy from the system or transferring energy within the system. It is proposed that the utility of passive devices is greatly enhanced by the use of redundant actuators. In a passive system, once motion is provided to the system, presumably by a human user, passive devices may be able to modify this motion to achieve a desired resultant trajectory. A mechanically passive, 2-Degree-of-Freedom (D.O.F.) manipulator has been designed and built. It is equipped with four passive actuators: two electromagnetic brakes and two electromagnetic clutches. This paper gives a review of the literature on passive and robotics and describes the experimental test bed used in this research. Several control algorithms are investigated, resulting in the formulation of a passive control law.

  10. Experimental Study on the Performance of IIST Passive Core Cooling System

    SciTech Connect

    Chin-Jang Chang; Chien-Hsiung Lee; Wen-Tan Hong; Wang, Lance L.C.

    2002-07-01

    The purpose of this study is to conduct the experiments at the Institute of Nuclear Energy Research (INER) Integral System Test (IIST) facility for evaluation of the performance of the passive core cooling system (PCCS) during the cold-leg small break loss-of-coolant accidents (SBLOCAs). Five experiments were performed with (1) three different break sizes, 2%, 0.5%, and 0.2% (approximately corresponding to 1 1/4'', 2'', and 4'' breaks for Maanshan nuclear power plant), and (2) 0.2% and 0.5% without actuation of the first-stage and third-stage automatic depressurization valve (ADS-1 and ADS-3) to initiate PCCS for assessing its capacity in accident management. The detailed descriptions of general system response and the interactions of core makeup tanks (CMTs), accumulators (ACCs), automatic depressurization system (ADS), passive residual heat Removal (PRHR), and in-containment refueling water storage tank (IRWST) on the core heat removal are included. The results show: (1) core long term cooling can be maintained for all cases following the PCCS procedures, (2) the core can be covered for the cases of the 0.2% and 0.5% breaks without actuation of ADS-1 and ADS-3. (authors)

  11. Passive solar house in Skillman, NJ: Case study

    SciTech Connect

    Kendig, J.

    1999-07-01

    This study traces the history of a single family residence in Skillman, NJ designed by Harrison Fraker. The house, built in 1978, was conceived as primarily passive solar house intended to rely on solar energy for most of its heating needs. Solar features include direct gain windows, water walls and sunspace. The study documents original solar features, identifies changes over time and evaluates performance of the house. The owners have removed movable insulation and significantly reduced the amount of thermal mass over the life of the building. The owner reported comfort level changes intuitively consistent with those modifications. The owner is contemplating further changes to make the house more marketable, changes likely to further alter the remaining passive solar features. Builders Guide software was used to calculate changes in solar performance of the house related to building modifications. Calculations of solar performance generally correspond to anecdotal information from the owner. The author's attempts with Energy 10 program showed some promise, but are as yet inconclusive. At this time BG appears to be more useful and user friendly to the average practitioner with limited time and design resources. As a practicing architect the author is most interested in lessons to be learned from the past as they might contribute to future projects. Information gleaned from this study did confirm intuitively expected and currently disseminated thinking regarding passive solar design. The thermal mass proved to be vulnerable to change. Features which required daily manual adjustment were quickly discarded. Desire for comfort was driving force in changing the house and took precedence over the need to save energy or money.

  12. Heat Rash or Prickly Heat (Miliaria Rubra)

    MedlinePlus

    ... heat rash consist of controlling heat and humidity. Acetaminophen or ibuprofen can help to reduce fever. Remove ... without any sweat. Your child may complain of dizziness, nausea, weakness, headache, confusion, or difficulty breathing. This ...

  13. Passive magnetic bearing configurations

    DOEpatents

    Post, Richard F.

    2011-01-25

    A journal bearing provides vertical and radial stability to a rotor of a passive magnetic bearing system when the rotor is not rotating and when it is rotating. In the passive magnetic bearing system, the rotor has a vertical axis of rotation. Without the journal bearing, the rotor is vertically and radially unstable when stationary, and is vertically stable and radially unstable when rotating.

  14. Passive solar construction handbook

    SciTech Connect

    Levy, E.; Evans, D.; Gardstein, C.

    1981-08-01

    Many of the basic elements of passive solar design are reviewed. The unique design constraints presented in passive homes are introduced and many of the salient issues influencing design decisions are described briefly. Passive solar construction is described for each passive system type: direct gain, thermal storage wall, attached sunspace, thermal storage roof, and convective loop. For each system type, important design and construction issues are discussed and case studies illustrating designed and built examples of the system type are presented. Construction details are given and construction and thermal performance information is given for the materials used in collector components, storage components, and control components. Included are glazing materials, framing systems, caulking and sealants, concrete masonry, concrete, brick, shading, reflectors, and insulators. The Load Collector Ratio method for estimating passive system performance is appended, and other analysis methods are briefly summarized. (LEW)

  15. Novel Power Electronics Three-Dimensional Heat Exchanger: Preprint

    SciTech Connect

    Bennion, K.; Cousineau, J.; Lustbader, J.; Narumanchi, S.

    2014-08-01

    Electric drive systems for vehicle propulsion enable technologies critical to meeting challenges for energy, environmental, and economic security. Enabling cost-effective electric drive systems requires reductions in inverter power semiconductor area. As critical components of the electric drive system are made smaller, heat removal becomes an increasing challenge. In this paper, we demonstrate an integrated approach to the design of thermal management systems for power semiconductors that matches the passive thermal resistance of the packaging with the active convective cooling performance of the heat exchanger. The heat exchanger concept builds on existing semiconductor thermal management improvements described in literature and patents, which include improved bonded interface materials, direct cooling of the semiconductor packages, and double-sided cooling. The key difference in the described concept is the achievement of high heat transfer performance with less aggressive cooling techniques by optimizing the passive and active heat transfer paths. An extruded aluminum design was selected because of its lower tooling cost, higher performance, and scalability in comparison to cast aluminum. Results demonstrated a heat flux improvement of a factor of two, and a package heat density improvement over 30%, which achieved the thermal performance targets.

  16. Condensation in horizontal heat exchanger tubes

    SciTech Connect

    Leyer, S.; Zacharias, T.; Maisberger, F.; Lamm, M.; Vallee, C.; Beyer, M.; Hampel, U.

    2012-07-01

    Many innovative reactor concepts for Generation III nuclear power plants use passive safety equipment for residual heat removal. These systems use two phase natural circulation. Heat transfer to the coolant results in a density difference providing the driving head for the required mass flow. By balancing the pressure drop the system finds its operational mode. Therefore the systems depend on a strong link between heat transfer and pressure drop determining the mass flow through the system. In order to be able to analyze these kind of systems with the help of state of the art computer codes the implemented numerical models for heat transfer, pressure drop or two phase flow structure must be able to predict the system performance in a wide parameter range. Goal of the program is to optimize the numerical models and therefore the performance of computer codes analyzing passive systems. Within the project the heat transfer capacity of a heat exchanger tube will be investigated. Therefore the tube will be equipped with detectors, both temperature and pressure, in several directions perpendicular to the tube axis to be able to resolve the angular heat transfer. In parallel the flow structure of a two phase flow inside and along the tube will be detected with the help of x-ray tomography. The water cooling outside of the tube will be realized by forced convection. It will be possible to combine the flow structure measurement with an angular resolved heat transfer for a wide parameter range. The test rig is set up at the TOPLFOW facility at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR), so that it will be possible to vary the pressure between 5 and 70 bar. The steam mass content will be varied between 0 and 100 percent. The results will be compared to the large scaled Emergency Condenser Tests performed at the INKA test facility in Karlstein (Germany). The paper will explain the test setup and the status of the project will be presented. (authors)

  17. Vertical diffusivities of active and passive tracers

    NASA Astrophysics Data System (ADS)

    Canuto, V. M.; Cheng, Y.; Howard, A. M.

    The climate models that include a carbon-cycle need the vertical diffusivity of a passive tracer. Since an expression for the latter is not available, it has been common practice to identify it with that of salt. The identification is questionable since T, S are active, not passive tracers. We present the first derivation of the diffusivity of a passive tracer in terms of Ri (Richardson number) and R ρ (density ratio, ratio of salinity over temperature z-gradients). The following results have emerged: The passive tracer diffusivity is an algebraic function of Ri, R ρ. In doubly stable regimes (DS, ∂ T/∂z > 0, ∂S/∂ z < 0), the passive scalar diffusivity is nearly the same as that of salt/heat for any values of R ρ < 0 and Ri > 0. In DC regimes (diffusive convection, ∂ T/∂ z < 0, ∂ S/∂ z < 0, R ρ > 1), the passive scalar diffusivity is larger than that of salt. At Ri = O(1), it can be more than twice as large. In SF regimes (salt fingers, ∂ T/∂ z > 0, ∂ S/∂ z > 0, R ρ < 1), the passive scalar diffusivity is smaller than that of salt. At Ri = O(1), it can be less than half of it. The passive tracer diffusivity predicted at the location of NATRE (North Atlantic Tracer Release Experiment) is discussed. Perhaps the most relevant conclusion is that the common identification of the tracer diffusivity with that of salt is valid only in DS regimes. In the Southern Ocean, where there is the largest CO 2 absorption, the dominant regime is diffusive convection discussed in (c) above.

  18. Vertical Diffusivities of Active and Passive Tracers

    NASA Technical Reports Server (NTRS)

    Canuto, V. M.; Cheng, Y.; Howard, A. M.

    2010-01-01

    The climate models that include a carbon-cycle need the vertical diffusivity of a passive tracer. Since an expression for the latter is not available, it has been common practice to identify it with that of salt. The identification is questionable since T, S are active, not passive tracers. We present the first derivation of the diffusivity of a passive tracer in terms of Ri (Richardson number) and Rq (density ratio, ratio of salinity over temperature z-gradients). The following results have emerged: (a) The passive tracer diffusivity is an algebraic function of Ri, Rq. (b) In doubly stable regimes (DS, partial derivative of T with respect to z > 0, partial derivative of S with respect to z < 0), the passive scalar diffusivity is nearly the same as that of salt/heat for any values of Rq < 0 and Ri > 0. (c) In DC regimes (diffusive convection, partial derivative of T with respect to z < 0, partial derivative of S with respect to z < 0, Rq > 1), the passive scalar diffusivity is larger than that of salt. At Ri = O(1), it can be more than twice as large. (d) In SF regimes (salt fingers, partial derivative of T with respect to z > 0, partial derivative of S with respect to z > 0, Rq < 1), the passive scalar diffusivity is smaller than that of salt. At Ri = O(1), it can be less than half of it. (e) The passive tracer diffusivity predicted at the location of NATRE (North Atlantic Tracer Release Experiment) is discussed. (f) Perhaps the most relevant conclusion is that the common identification of the tracer diffusivity with that of salt is valid only in DS regimes. In the Southern Ocean, where there is the largest CO2 absorption, the dominant regime is diffusive convection discussed in (c) above.

  19. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOEpatents

    McDermott, D.J.; Schrader, K.J.; Schulz, T.L.

    1994-05-03

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  20. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOEpatents

    McDermott, Daniel J.; Schrader, Kenneth J.; Schulz, Terry L.

    1994-01-01

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  1. Thulium-170 heat source

    SciTech Connect

    Walter, C.E.; Van Konynenburg, R.; Van Sant, J.H.

    1992-01-21

    This patent describes an isotopic heat source. It comprises; at least one isotopic fuel stack, comprising alternating layers of: thulium oxide; and a low atomic weight diluent for thulium oxide; a heat block defining holes into which the fuel stacks can be placed; at least one heat pipe for heat removal, with the heat pipe being positioned in the heat block in thermal connection with the fuel stack; and a structural container surrounding the heat block.

  2. Adenoid removal

    MedlinePlus

    ... This does not cause problems most of the time. Alternative Names Adenoidectomy; Removal of adenoid glands Images Adenoid removal - series References Wetmore RF. Tonsils and adenoids. In: Kliegman ...

  3. Electrochemical-thermal modeling and microscale phase change for passive internal thermal management of lithium ion batteries.

    SciTech Connect

    Fuller, Thomas F.; Bandhauer, Todd; Garimella, Srinivas

    2012-01-01

    A fully coupled electrochemical and thermal model for lithium-ion batteries is developed to investigate the impact of different thermal management strategies on battery performance. In contrast to previous modeling efforts focused either exclusively on particle electrochemistry on the one hand or overall vehicle simulations on the other, the present work predicts local electrochemical reaction rates using temperature-dependent data on commercially available batteries designed for high rates (C/LiFePO{sub 4}) in a computationally efficient manner. Simulation results show that conventional external cooling systems for these batteries, which have a low composite thermal conductivity ({approx}1 W/m-K), cause either large temperature rises or internal temperature gradients. Thus, a novel, passive internal cooling system that uses heat removal through liquid-vapor phase change is developed. Although there have been prior investigations of phase change at the microscales, fluid flow at the conditions expected here is not well understood. A first-principles based cooling system performance model is developed and validated experimentally, and is integrated into the coupled electrochemical-thermal model for assessment of performance improvement relative to conventional thermal management strategies. The proposed cooling system passively removes heat almost isothermally with negligible thermal resistances between the heat source and cooling fluid. Thus, the minimization of peak temperatures and gradients within batteries allow increased power and energy densities unencumbered by thermal limitations.

  4. Combining Passive Thermography and Acoustic Emission for Large Area Fatigue Damage Growth Assessment of a Composite Structure

    NASA Technical Reports Server (NTRS)

    Zalameda, Joseph N.; Horne, Michael R.; Madaras, Eric I.; Burke, Eric R.

    2016-01-01

    Passive thermography and acoustic emission data were obtained for improved real time damage detection during fatigue loading. A strong positive correlation was demonstrated between acoustic energy event location and thermal heating, especially if the structure under load was nearing ultimate failure. An image processing routine was developed to map the acoustic emission data onto the thermal imagery. This required removing optical barrel distortion and angular rotation from the thermal data. The acoustic emission data were then mapped onto thermal data, revealing the cluster of acoustic emission event locations around the thermal signatures of interest. By combining both techniques, progression of damage growth is confirmed and areas of failure are identified. This technology provides improved real time inspections of advanced composite structures during fatigue testing.Keywords: Thermal nondestructive evaluation, fatigue damage detection, aerospace composite inspection, acoustic emission, passive thermography

  5. Increase in the optical damage threshold of a ZnSe-passivated front mirror of a laser diode

    SciTech Connect

    Davydova, Evgeniya I; Dmitriev, V V; Kozlov, Yu Yu; Kukushkin, I A; Uspenskiy, Mikhail B; Shishkin, Viktor A

    2011-05-31

    The operation of single-mode diode lasers with a front mirror passivated by ZnSe films of different thicknesses is studied in the pulsed regime (pulse duration {tau} = 0.2 - 10 {mu}s). It is found that in the case of short (0.2 {mu}s) pulses, the catastrophic optical damage threshold grows almost linearly as the film thickness on the front mirror increases from 0.1 to 0.5 {mu}m. It is shown that lasers with mirrors passivated by 'thick' (0.4 - 0.6 {mu}m) ZnSe films can operate stably in the case of 'long' (2 - 10 {mu}s) pulses. It is assumed that in this pulsed regime the ZnSe film provides an additional heat removal from the hot zone of the front mirror, and consequently increases the optical damage threshold. (lasers)

  6. Climate-Specific Passive Building Standards

    SciTech Connect

    Wright, Graham S.; Klingenberg, Katrin

    2015-07-01

    Passive design principles (super insulation, airtight envelopes, elimination of thermal bridges, etc.) - pioneered in North America in the 70s and 80s and refined in Europe in the 90s have proven to be universally effective to significantly reduce heating and cooling loads. However, a single, rigid performance metric developed in Germany has led to limited uptake of passive building principles in many regions of the United States. It has also, in many cases, promoted some design decisions that had negative effects on economic feasibility and thermal comfort. This study's main objective is to validate (in a theoretical sense) verifiable, climate-specific passive standards and space conditioning criteria that retain ambitious, environmentally-necessary energy reduction targets and are economically feasible, such standards provide designers an ambitious but achievable performance target on the path to zero.

  7. Immunizations: Active vs. Passive

    MedlinePlus

    ... they’ve been exposed. For example, the passive rabies immunization (rabies immune globulin) is commonly used after a certain ... of your pediatrician. There may be variations in treatment that your pediatrician may recommend based on individual ...

  8. Hood River Passive House

    SciTech Connect

    Hales, D.

    2013-03-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project.

  9. Passive adaptive imaging through turbulence

    NASA Astrophysics Data System (ADS)

    Tofsted, David

    2016-05-01

    Standard methods for improved imaging system performance under degrading optical turbulence conditions typically involve active adaptive techniques or post-capture image processing. Here, passive adaptive methods are considered where active sources are disallowed, a priori. Theoretical analyses of short-exposure turbulence impacts indicate that varying aperture sizes experience different degrees of turbulence impacts. Smaller apertures often outperform larger aperture systems as turbulence strength increases. This suggests a controllable aperture system is advantageous. In addition, sub-aperture sampling of a set of training images permits the system to sense tilts in different sub-aperture regions through image acquisition and image cross-correlation calculations. A four sub-aperture pattern supports corrections involving five realizable operating modes (beyond tip and tilt) for removing aberrations over an annular pattern. Progress to date will be discussed regarding development and field trials of a prototype system.

  10. Open-loop heat-recovery dryer

    SciTech Connect

    TeGrotenhuis, Ward Evan

    2013-11-05

    A drying apparatus is disclosed that includes a drum and an open-loop airflow pathway originating at an ambient air inlet, passing through the drum, and terminating at an exhaust outlet. A passive heat exchanger is included for passively transferring heat from air flowing from the drum toward the exhaust outlet to air flowing from the ambient air inlet toward the drum. A heat pump is also included for actively transferring heat from air flowing from the passive heat exchanger toward the exhaust outlet to air flowing from the passive heat exchanger toward the drum. A heating element is also included for further heating air flowing from the heat pump toward the drum.

  11. Heat exchange enhancement structure

    SciTech Connect

    Cornelison, R.C.; Kreith, F.

    1980-12-02

    A passive heat exchange enhancement structure which operates by free convection includes a flat mounting portion having a plurality of integral fins bent outwardly from one side edge thereof. The mounting portion is securable around a stovepipe, to a flat surface or the like for transferring heat from the pipe through the fins to the surrounding air by rotation-enhanced free convection.

  12. National Passive Solar Conference, 4th, Kansas City, MO, October 3-5, 1979, Proceedings. Volume 4

    NASA Astrophysics Data System (ADS)

    Franta, G.

    1981-10-01

    Papers concern recent experience in the research, development and application of passive solar technology. Specific topics include the legislative barriers and incentives to passive solar systems, coupled thermal and lighting simulations for evaluating daylighting design effectiveness, passive solar applications in inner city housing, radiative cooling in a desert climate, salinity gradient solar ponds, the retrofit of a masonry home for passive space heating, the performances of active and passive solar domestic hot water systems, builder experience with passive solar home construction, the use of solar energy installations on farm buildings, and a method of determining the thermal performance of passive storage walls.

  13. Methane cryogenic heat pipe for space use with a liquid trap for on-off switching

    NASA Astrophysics Data System (ADS)

    Cepeda-Rizo, Juan; Rodriguez, Jose Israel; Bugby, David

    2012-06-01

    A methane cryogenic heat pipe with a liquid trap for on-off actuation was developed by ATK for use on Jet Propulsion Laboratory's Space Interferometer Mission Lite (SIM Lite) pre-Phase A hardware technology demonstration tests. The cryogenic heat pipe coupled to a cold radiator at 160K provides cooling to the Charged Coupled Device camera focal planes. The heat pipe was designed for a transport capacity of 15 W across a 1.5 m span through a near room-temperature spacecraft environment. A key and driving requirement for the heat pipe was the need for switching the heat pipe on and off needed to support low power decontamination cycles to near room temperature of the cryogenic focal planes. The cryogenic heat pipe is turned off by removing the methane working fluid from the heat pipe and storing in the liquid trap. The heat pipe is turned-on by simply reintroducing the working fluid from the liquid trap. This on-off switching capability is a key requirement for cryogenic heat pipes used with passive or active cryocoolers for cooling focal planes or optics. This switching capability provides a means to decouple a cold focal plane or optics from a redundant stand-by cryocooler or a passive cooler when in need for a decontamination cycle.

  14. Active heat exchange system development for latent heat thermal energy storage

    NASA Technical Reports Server (NTRS)

    Alario, J.; Kosson, R.; Haslett, R.

    1980-01-01

    Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application (300 MW sub t storage for 6 hours). Two concepts were selected for hardware development: (1) a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and (2) a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which was nickel plated to decrease adhesion forces. In addition to improving performance by providing a nearly constant transfer rate during discharge, these active heat exchanger concepts were estimated to cost at least 25% less than the passive tube-shell design.

  15. Passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1989-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  16. Natural circulating passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1990-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  17. Robust Cooling of High Heat Fluxes Using Hybrid Loop Technology

    NASA Astrophysics Data System (ADS)

    Zuo, Jon; Park, Chanwoo; Sarraf, David; Paris, Anthony

    2005-02-01

    This paper discusses the development of an advanced hybrid loop technology that incorporates elements from both passive and active loop technologies. The result is a simple yet high performance cooling technology that can be used to remove high heat fluxes from large heat input areas. Operating principles and test results of prototype hybrid loops are discussed. Prototype hybrid loops have been demonstrated to remove heat fluxes in excess of 350W/cm2 from heat input areas over 4cm2 with evaporator thermal resistances between 0.008 and 0.065°C/W/cm2. Also importantly, this performance was achieved without the need to actively adjust or control the flows in the loops, even when the heat inputs varied between 0 and 350W/cm2. These performance characteristics represent substantial improvements over state of the art heat pipes, loop heat pipes and spray cooling devices. The hybrid loop technology was demonstrated to operate effectively at all orientations.

  18. Passively cooled direct drive wind turbine

    DOEpatents

    Costin, Daniel P.

    2008-03-18

    A wind turbine is provided that passively cools an electrical generator. The wind turbine includes a plurality of fins arranged peripherally around a generator house. Each of the fins being oriented at an angle greater than zero degrees to allow parallel flow of air over the fin. The fin is further tapered to allow a constant portion of the fin to extend beyond the air stream boundary layer. Turbulence initiators on the nose cone further enhance heat transfer at the fins.

  19. Passive modal damping with piezoelectric shunts

    SciTech Connect

    Granier, J. J.; Haundhausen, R. J.; Gaytan, G. E.

    2001-01-01

    The use of piezoelectric materials in conjunction with passive inductance-resistance-capacitance (RLC) circuits to dampen specific vibration modes is explored. The piezoelectric materials convert mechanical energy to electrical energy, which is then dissipated in the RLC circuit through joule heating. An impulse is applied to a simple cantilevered beam and by varying the inductance and resistance values, the natural oscillation frequency fcir the RLC circuit is tuned to dampen the first mode of vibration.

  20. Tierra Nueva -- A passive solar cohousing project

    SciTech Connect

    Haggard, K.; Cooper, P.

    1999-10-01

    California architects take on the formidable challenges of designing a cohousing project, and discover that the end result is well worth the effort. The Tierra Nueva Cohousing Project consists of living units, a common house, community orchard, community gardens, community play space, space for a future shop and at the periphery of the site, parking, carports and garages. The units use thermal mass, solar heating, passive solar cooling, perimeter insulation on slabs. Design was agreed to by the community as a whole.

  1. Kidney removal

    MedlinePlus

    ... the surgical cut is located. Recovery after a laparoscopic procedure is most often quicker, with less pain. Outlook (Prognosis) The outcome is most often good when a single kidney is removed. If both kidneys are removed, ...

  2. Tick Removal

    MedlinePlus

    ... ticks Tickborne diseases abroad Borrelia miyamotoi Borrelia mayonii Tick Removal Recommend on Facebook Tweet Share Compartir If ... a tick quite effectively. How to remove a tick Use fine-tipped tweezers to grasp the tick ...

  3. Thulium-170 heat source

    SciTech Connect

    Walter, C.E.; Van Konynenburg, R.; VanSant, J.H.

    1990-09-06

    An isotopic heat source is formed using stacks of thin individual layers of a refractory isotopic fuel, preferably thulium oxide, alternating with layers of a low atomic weight diluent, preferably graphite. The graphite serves several functions: to act as a moderator during neutron irradiation, to minimize bremsstrahlung radiation, and to facilitate heat transfer. The fuel stacks are inserted into a heat block, which is encased in a sealed, insulated and shielded structural container. Heat pipes are inserted in the heat block and contain a working fluid. The heat pipe working fluid transfers heat from the heat block to a heat exchanger for power conversion. Single phase gas pressure controls the flow of the working fluid for maximum heat exchange and to provide passive cooling.

  4. Thulium-170 heat source

    DOEpatents

    Walter, Carl E.; Van Konynenburg, Richard; VanSant, James H.

    1992-01-01

    An isotopic heat source is formed using stacks of thin individual layers of a refractory isotopic fuel, preferably thulium oxide, alternating with layers of a low atomic weight diluent, preferably graphite. The graphite serves several functions: to act as a moderator during neutron irradiation, to minimize bremsstrahlung radiation, and to facilitate heat transfer. The fuel stacks are inserted into a heat block, which is encased in a sealed, insulated and shielded structural container. Heat pipes are inserted in the heat block and contain a working fluid. The heat pipe working fluid transfers heat from the heat block to a heat exchanger for power conversion. Single phase gas pressure controls the flow of the working fluid for maximum heat exchange and to provide passive cooling.

  5. Thermal Hydraulic Challenges of Gas Cooled Fast Reactors with Passive Safety Features

    SciTech Connect

    Michael Pope; Jeong-Ik Lee; Pavel Hejzlar; Michael J. Driscoll

    2009-05-01

    Transient response of a Gas cooled Fast Reactor (GFR) coupled to a recompression supercritical CO2 (S-CO2) power conversion system (PCS) in a direct cycle to Loss of Coolant and Loss of Generator Load Accidents is analyzed using RELAP5-3D. A number of thermal hydraulic challenges for GFR design are pointed out as the designers strive to accommodate cooling of the high power density core of a fast reactor by a gas with its inherently low heat transfer capability, in particular under post LOCA events when system pressure is lost and when reliance on passive decay heat removal is emphasized. Although it is possible to design a S-CO2 cooled GFR that can survive LOCA by cooling the core through natural circulating loops between the core and elevated emergency cooling heat exchangers, it is not an attractive approach because of various bypass paths that can, depending on break location, degrade core cooling. Moreover, natural circulation gas loops can operate in deteriorated heat transfer regimes with substantial reduction of heat transfer coefficient: as low as 30% of forced convection values, and data and correlations in these regimes carry large uncertainties. Therefore, reliable battery powered blowers for post-LOCA decay heat removal (DHR) that provide flow in well defined regimes with low uncertainty, and can be easily over-designed to accommodate bypass flows were selected. The results confirm that a GFR with such a DHR system and negative coolant void worth can withstand LOCA with and without scram as well as loss of electrical load without exceeding core temperature and turbomachinery overspeed limits.

  6. Wireless passive radiation sensor

    SciTech Connect

    Pfeifer, Kent B; Rumpf, Arthur N; Yelton, William G; Limmer, Steven J

    2013-12-03

    A novel measurement technique is employed using surface acoustic wave (SAW) devices, passive RF, and radiation-sensitive films to provide a wireless passive radiation sensor that requires no batteries, outside wiring, or regular maintenance. The sensor is small (<1 cm.sup.2), physically robust, and will operate unattended for decades. In addition, the sensor can be insensitive to measurement position and read distance due to a novel self-referencing technique eliminating the need to measure absolute responses that are dependent on RF transmitter location and power.

  7. Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link

    NASA Technical Reports Server (NTRS)

    Hartenstine, John; Anderson, William G.; Walker, Kara; Dussinger, Pete

    2012-01-01

    Future lunar landers and rovers will require variable thermal links that allow for heat rejection during the lunar daytime and passively prevent heat rejection during the lunar night. During the lunar day, the thermal management system must reject the waste heat from the electronics and batteries to maintain them below the maximum acceptable temperature. During the lunar night, the heat rejection system must either be shut down or significant amounts of guard heat must be added to keep the electronics and batteries above the minimum acceptable temperature. Since guard heater power is unfavorable because it adds to system size and complexity, a variable thermal link is preferred to limit heat removal from the electronics and batteries during the long lunar night. Conventional loop heat pipes (LHPs) can provide the required variable thermal conductance, but they still consume electrical power to shut down the heat transfer. This innovation adds a thermal control valve (TCV) and a bypass line to a conventional LHP that proportionally allows vapor to flow back into the compensation chamber of the LHP. The addition of this valve can achieve completely passive thermal control of the LHP, eliminating the need for guard heaters and complex controls.

  8. Method of passivating semiconductor surfaces

    DOEpatents

    Wanlass, M.W.

    1990-06-19

    A method is described for passivating Group III-V or II-VI semiconductor compound surfaces. The method includes selecting a passivating material having a lattice constant substantially mismatched to the lattice constant of the semiconductor compound. The passivating material is then grown as an ultrathin layer of passivating material on the surface of the Group III-V or II-VI semiconductor compound. The passivating material is grown to a thickness sufficient to maintain a coherent interface between the ultrathin passivating material and the semiconductor compound. In addition, a device formed from such method is also disclosed.

  9. Method of passivating semiconductor surfaces

    DOEpatents

    Wanlass, Mark W.

    1990-01-01

    A method of passivating Group III-V or II-VI semiconductor compound surfaces. The method includes selecting a passivating material having a lattice constant substantially mismatched to the lattice constant of the semiconductor compound. The passivating material is then grown as an ultrathin layer of passivating material on the surface of the Group III-V or II-VI semiconductor compound. The passivating material is grown to a thickness sufficient to maintain a coherent interface between the ultrathin passivating material and the semiconductor compound. In addition, a device formed from such method is also disclosed.

  10. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    SciTech Connect

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.; Rohatgi, U.S.

    1995-09-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba`s Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations al these conditions were compared with the GIRAFFE data. The effects of PCCS cell nodings on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to {+-}5% of the data with a three-node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer in the presence of noncondensable gases with only a coarse mesh. The cell length term in the condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes.

  11. Passive Magnetic Bearing

    NASA Technical Reports Server (NTRS)

    Studer, P. A.

    1983-01-01

    Magnetic bearing for limited rotation devices requires no feedback control system to sense and correct shaft position. Passive Magnetic Torsion Bearing requires no power supply and has no rubbing parts. Torsion wire restrains against axial instability. Magnetic flux geometry chosen to assure lateral stability with radial restoring force that maintains alignment.

  12. Passive Cooling of Body Armor

    NASA Astrophysics Data System (ADS)

    Holtz, Ronald; Matic, Peter; Mott, David

    2013-03-01

    Warfighter performance can be adversely affected by heat load and weight of equipment. Current tactical vest designs are good insulators and lack ventilation, thus do not provide effective management of metabolic heat generated. NRL has undertaken a systematic study of tactical vest thermal management, leading to physics-based strategies that provide improved cooling without undesirable consequences such as added weight, added electrical power requirements, or compromised protection. The approach is based on evaporative cooling of sweat produced by the wearer of the vest, in an air flow provided by ambient wind or ambulatory motion of the wearer. Using an approach including thermodynamic analysis, computational fluid dynamics modeling, air flow measurements of model ventilated vest architectures, and studies of the influence of fabric aerodynamic drag characteristics, materials and geometry were identified that optimize passive cooling of tactical vests. Specific architectural features of the vest design allow for optimal ventilation patterns, and selection of fabrics for vest construction optimize evaporation rates while reducing air flow resistance. Cooling rates consistent with the theoretical and modeling predictions were verified experimentally for 3D mockups.

  13. Passive solar progress: a simplified guide to the 3rd national passive solar conference

    SciTech Connect

    Miller, H.; Howell, Y.; Richards, D.

    1980-10-01

    Some of the concepts and practices that have come to be known as passive solar heating and cooling are introduced, and a current picture of the field is presented. Much of the material presented is derived from papers given at the 3rd National Passive Solar Conference held in San Jose, California in January 1979 and sponsored by the US Department of Energy. Extracts and data from these papers have been integrated in the text with explanatory and descriptive material. In this way, it is attempted to present technical information in an introductory context. Topics include design considerations, passive and hybrid systems and applications, sizing methods and performance prediction, and implementation issues. A glossary is included. (WHK)

  14. A corrosive resistant heat exchanger

    DOEpatents

    Richlen, S.L.

    1987-08-10

    A corrosive and erosive resistant heat exchanger which recovers heat from a contaminated heat stream. The heat exchanger utilizes a boundary layer of innocuous gas, which is continuously replenished, to protect the heat exchanger surface from the hot contaminated gas. The innocuous gas is pumped through ducts or perforations in the heat exchanger wall. Heat from the heat stream is transferred by radiation to the heat exchanger wall. Heat is removed from the outer heat exchanger wall by a heat recovery medium. 3 figs., 3 tabs.

  15. Positioning Your Library for Solar (and Financial) Gain. Improving Energy Efficiency, Lighting, and Ventilation with Primarily Passive Techniques

    ERIC Educational Resources Information Center

    Shane, Jackie

    2012-01-01

    This article stresses the importance of building design above technology as a relatively inexpensive way to reduce energy costs for a library. Emphasis is placed on passive solar design for heat and daylighting, but also examines passive ventilation and cooling, green roofs, and building materials. Passive design is weighed against technologies…

  16. HTR-100 industrial nuclear power plant for generation of heat and electricity

    SciTech Connect

    Brandes, S.; Kohl, W.

    1987-11-01

    Based on their proven high-temperature reactor (HTR) with pebble-bed core, Brown, Boveri and Cie/Hochtemperatur-Reaktorbau have developed an HTR-100 plant that combines favorable capital costs and high availability. Due to the high HTR-specific standards and passive safety features, this plant is especially well suited for siting near the end user. The safety concept permits further operation of the plant or decay heat removal via the operational heat sinks in the event of maloperation and design basis accidents having a higher probability of occurrence. In the event of hypothetical accidents, the decay heat is removed from the reactor pressure vessel by radiation, conduction, and convection to a concrete cooling system operating in natural convection. As an example of the new HTR-100 plant concept, a twin-block plant design for extraction of industrial steam is presented.

  17. High removal rate laser-based coating removal system

    DOEpatents

    Matthews, Dennis L.; Celliers, Peter M.; Hackel, Lloyd; Da Silva, Luiz B.; Dane, C. Brent; Mrowka, Stanley

    1999-11-16

    A compact laser system that removes surface coatings (such as paint, dirt, etc.) at a removal rate as high as 1000 ft.sup.2 /hr or more without damaging the surface. A high repetition rate laser with multiple amplification passes propagating through at least one optical amplifier is used, along with a delivery system consisting of a telescoping and articulating tube which also contains an evacuation system for simultaneously sweeping up the debris produced in the process. The amplified beam can be converted to an output beam by passively switching the polarization of at least one amplified beam. The system also has a personal safety system which protects against accidental exposures.

  18. Thermal-hydraulic simulation of natural convection decay heat removal in the High Flux Isotope Reactor (HFIR) using RELAP5 and TEMPEST: Part 2, Interpretation and validation of results

    SciTech Connect

    Ruggles, A.E.; Morris, D.G.

    1989-01-01

    The RELAP5/MOD2 code was used to predict the thermal-hydraulic behavior of the HFIR core during decay heat removal through boiling natural circulation. The low system pressure and low mass flux values associated with boiling natural circulation are far from conditions for which RELAP5 is well exercised. Therefore, some simple hand calculations are used herein to establish the physics of the results. The interpretation and validation effort is divided between the time average flow conditions and the time varying flow conditions. The time average flow conditions are evaluated using a lumped parameter model and heat balance. The Martinelli-Nelson correlations are used to model the two-phase pressure drop and void fraction vs flow quality relationship within the core region. Systems of parallel channels are susceptible to both density wave oscillations and pressure drop oscillations. Periodic variations in the mass flux and exit flow quality of individual core channels are predicted by RELAP5. These oscillations are consistent with those observed experimentally and are of the density wave type. The impact of the time varying flow properties on local wall superheat is bounded herein. The conditions necessary for Ledinegg flow excursions are identified. These conditions do not fall within the envelope of decay heat levels relevant to HFIR in boiling natural circulation. 14 refs., 5 figs., 1 tab.

  19. Passive-solar design manual for the United States Navy

    SciTech Connect

    Wray, W.O.; Biehl, F.A.; Kosiewicz, C.R.; Miles, C.R. Durlak, E.R.

    1982-01-01

    A passive solar design manual for single-family detached residences and dormitory-type buildings is being developed. The design procedure employed in the manual is a simplification of the original monthly solar load ratio (SLR) method. The new SLR correlations involve a single constant for each system. The correlation constant appears as a scale factor permitting the use of a universal performance curve for all passive systems. Furthermore, by providing location-dependent correlations between the annual solar heating fraction (SHF)* and the minimum monthly SHF, we have eliminated the need to perform an SLR calculation for each month of the heating season.

  20. Preparation, characterization and dissolution of passive oxide film on the 400 series stainless steel surfaces

    NASA Astrophysics Data System (ADS)

    Sathyaseelan, V. S.; Rufus, A. L.; Chandramohan, P.; Subramanian, H.; Velmurugan, S.

    2015-12-01

    Full system decontamination of Primary Heat Transport (PHT) system of Pressurised Heavy Water Reactors (PHWRs) resulted in low decontamination factors (DF) on stainless steel (SS) surfaces. Hence, studies were carried out with 403 SS and 410 SS that are the material of construction of "End-Fitting body" and "End-Fitting Liner tubes". Three formulations were evaluated for the dissolution of passive films formed over these alloys viz., i) Two-step process consisting of oxidation and reduction reactions, ii) Dilute Chemical Decontamination (DCD) and iii) High Temperature Process. The two-step and high temperature processes could dissolve the oxide completely while the DCD process could remove only 60%. Various techniques like XRD, Raman spectroscopy and SEM-EDX were used for assessing the dissolution process. The two-step process is time consuming, laborious while the high temperature process is less time consuming and is recommended for SS decontamination.

  1. Reliability Evaluation of Passive Systems Through Functional Reliability Assessment

    SciTech Connect

    Burgazzi, Luciano

    2003-11-15

    A methodology, to quantify the reliability of passive safety systems, proposed for use in advanced reactor design, is developed. Passive systems are identified as systems that do not need any external input or energy to operate and rely only upon natural physical laws (e.g., gravity, natural circulation, heat conduction, internally stored energy, etc.) and/or intelligent use of the energy inherently available in the system (e.g., chemical reaction, decay heat, etc.). The reliability of a passive system refers to the ability of the system to carry out the required function under the prevailing condition when required: The passive system may fail its mission, in addition to the classical mechanical failure of its components, for deviation from the expected behavior, due to physical phenomena or to different boundary and initial conditions. The present research activity is finalized at the reliability estimation of passive B systems (i.e., implementing moving working fluids, see IAEA); the selected system is a loop operating in natural circulation including a heat source and a heat sink.The functional reliability concept, defined as the probability to perform the required mission, is introduced, and the R-S (Resistance-Stress) model taken from fracture mechanics is adopted. R and S are coined as expressions of functional Requirement and system State. Water mass flow circulating through the system is accounted as a parameter defining the passive system performance, and probability distribution functions (pdf's) are assigned to both R and S quantities; thus, the mission of the passive system defines which parameter values are considered a failure by comparing the corresponding pdfs according to a defined safety criteria. The methodology, its application, and results of the analysis are presented and discussed.

  2. Characterization Testing of the Teledyne Passive Breadboard Fuel Cell Powerplant

    NASA Technical Reports Server (NTRS)

    Loyselle, Patricia; Prokopius, Kevin

    2011-01-01

    NASA's Exploration Technology Development Program (ETDP) is tasked with the development of enabling and enhancing technologies for NASA's exploration missions. As part of that initiative, the return to the Moon requires a reliable, efficient, and lightweight fuel cell powerplant system to provide power to the Altair Lunar Lander and for lunar surface systems. Fuel cell powerplants are made up of two basic parts; the fuel cell itself and the supporting ancillary subsystem. This subsystem is designed to deliver reactants to the fuel cell and remove product water and waste heat from the fuel cell. Typically, fuel cell powerplant ancillary subsystems rely upon pumps and active water separation techniques to accomplish these tasks for closed hydrogen/oxygen systems. In a typical system, these components are the largest contributors to the overall parasitic power load of the fuel cell powerplant. A potential step towards the development of an efficient lightweight power system is to maximize the use of "passive" or low-power ancillary components as a replacement to these high-power load components

  3. Passively actuated valve

    SciTech Connect

    Modro, S. Michael; Ougouag, Abderrafi M.

    2005-09-20

    A passively actuated valve for isolating a high pressure zone from a low pressure zone and discontinuing the isolation when the pressure in the high pressure zone drops below a preset threshold. If the pressure in the high pressure zone drops below the preset threshold, the valve opens and allows flow from the high pressure zone to the low pressure zone. The valve remains open allowing pressure equalization and back-flow should a pressure inversion between the two pressure zone occur.

  4. Passive fetal monitoring sensor

    NASA Astrophysics Data System (ADS)

    Zuckerwar, Allan J.; Hall, Earl T.; Baker, Donald A.; Bryant, Timothy D.

    1992-08-01

    An ambulatory, passive sensor for use in a fetal monitoring system is discussed. The invention is comprised of a piezoelectric polymer film, combined with a metallic mounting plate fastened to a belt, and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted by a fetus inside an expectant mother. Additionally, the monitor will filter out pressure pulses arising from other sources, such as the maternal heart.

  5. Passive fetal monitoring sensor

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Hall, Earl T. (Inventor); Baker, Donald A. (Inventor); Bryant, Timothy D. (Inventor)

    1992-01-01

    An ambulatory, passive sensor for use in a fetal monitoring system is discussed. The invention is comprised of a piezoelectric polymer film, combined with a metallic mounting plate fastened to a belt, and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted by a fetus inside an expectant mother. Additionally, the monitor will filter out pressure pulses arising from other sources, such as the maternal heart.

  6. End-of-Mission Passivation: Successes and Challenges

    NASA Technical Reports Server (NTRS)

    Johnson, Nicholas; Matney, Mark

    2012-01-01

    The passivation of spacecraft and launch vehicle orbital stages at end-of-mission has been a principal space debris mitigation measure world-wide since the 1980 s. Space vehicle passivation includes the removal of stored energies, especially those associated with propulsion and electrical power systems. Prior to 2007 the breakup of non-functioning, non-passivated space vehicles was the major source of hazardous debris in Earth orbit. The United Nations and the Inter-Agency Space Debris Coordination Committee have both included passivation in their formal space debris mitigation guidelines. This often simple countermeasure has been adopted by many spacefaring countries and organizations and has undoubtedly prevented numerous major satellite breakups. For some existing space vehicle designs, passivation requires changes in hardware, software, and/or operational procedures. Questions about the permissible degree of passivation for both current and future space vehicles have arisen and are addressed herein. An important element to be considered is the potentially long period in which the space vehicle will remain in orbit, i.e., up to 25 years after mission termination in LEO and for centuries in orbits above LEO. Finally, the issue of passivation of space vehicles which have failed prematurely is addressed.

  7. Passive infrared ice detection for helicopter applications

    NASA Technical Reports Server (NTRS)

    Dershowitz, Adam L.; Hansman, R. John, Jr.

    1990-01-01

    A technique is proposed to remotely detect rotor icing on helicopters by using passive IR thermometry to detect the warming caused by latent heat release as supercooled water freezes. During icing, the ice accretion region will be warmer than the uniced trailing edge, resulting in a characteristic chordwise temperature profile. Preliminary tests were conducted on a static model in the NASA Icing Research Tunnel for a variety of wet (glaze) and dry (rime) ice conditions. The chordwise temperature profiles were confirmed by observation with an IR thermal video system and thermocouple observations. The IR observations were consistent with predictions of the LEWICE ice accretion code, which was used to extrapolate the observations to rotor icing conditions. Based on the static observations, the passive IR ice detection technique appears promising; however, further testing or rotating blades is required.

  8. Monogroove liquid heat exchanger

    NASA Technical Reports Server (NTRS)

    Brown, Richard F. (Inventor); Edelstein, Fred (Inventor)

    1990-01-01

    A liquid supply control is disclosed for a heat transfer system which transports heat by liquid-vapor phase change of a working fluid. An assembly (10) of monogroove heat pipe legs (15) can be operated automatically as either heat acquisition devices or heat discharge sources. The liquid channels (27) of the heat pipe legs (15) are connected to a reservoir (35) which is filled and drained by respective filling and draining valves (30, 32). Information from liquid level sensors (50, 51) on the reservoir (35) is combined (60) with temperature information (55) from the liquid heat exchanger (12) and temperature information (56) from the assembly vapor conduit (42) to regulate filling and draining of the reservoir (35), so that the reservoir (35) in turn serves the liquid supply/drain needs of the heat pipe legs (15), on demand, by passive capillary action (20, 28).

  9. Mechanisms of Ocean Heat Uptake

    NASA Astrophysics Data System (ADS)

    Garuba, Oluwayemi

    An important parameter for the climate response to increased greenhouse gases or other radiative forcing is the speed at which heat anomalies propagate downward in the ocean. Ocean heat uptake occurs through passive advection/diffusion of surface heat anomalies and through the redistribution of existing temperature gradients due to circulation changes. Atlantic meridional overturning circulation (AMOC) weakens in a warming climate and this should slow the downward heat advection (compared to a case in which the circulation is unchanged). However, weakening AMOC also causes a deep warming through the redistributive effect, thus increasing the downward rate of heat propagation compared to unchanging circulation. Total heat uptake depends on the combined effect of these two mechanisms. Passive tracers in a perturbed CO2 quadrupling experiments are used to investigate the effect of passive advection and redistribution of temperature anomalies. A new passive tracer formulation is used to separate ocean heat uptake into contributions due to redistribution and passive advection-diffusion of surface heating during an ocean model experiment with abrupt increase in surface temperature. The spatial pattern and mechanisms of each component are examined. With further experiments, the effects of surface wind, salinity and temperature changes in changing circulation and the resulting effect on redistribution in the individual basins are isolated. Analysis of the passive advection and propagation path of the tracer show that the Southern ocean dominates heat uptake, largely through vertical and horizontal diffusion. Vertical diffusion transports the tracer across isopycnals down to about 1000m in 100 years in the Southern ocean. Advection is more important in the subtropical cells and in the Atlantic high latitudes, both with a short time scale of about 20 years. The shallow subtropical cells transport the tracer down to about 500m along isopycnal surfaces, below this vertical

  10. Passive Noise Filtering by Cellular Compartmentalization.

    PubMed

    Stoeger, Thomas; Battich, Nico; Pelkmans, Lucas

    2016-03-10

    Chemical reactions contain an inherent element of randomness, which presents itself as noise that interferes with cellular processes and communication. Here we discuss the ability of the spatial partitioning of molecular systems to filter and, thus, remove noise, while preserving regulated and predictable differences between single living cells. In contrast to active noise filtering by network motifs, cellular compartmentalization is highly effective and easily scales to numerous systems without requiring a substantial usage of cellular energy. We will use passive noise filtering by the eukaryotic cell nucleus as an example of how this increases predictability of transcriptional output, with possible implications for the evolution of complex multicellularity. PMID:26967282

  11. Heat Pipe Materials Compatibility

    NASA Technical Reports Server (NTRS)

    Eninger, J. E.; Fleischman, G. L.; Luedke, E. E.

    1976-01-01

    An experimental program to evaluate noncondensable gas generation in ammonia heat pipes was completed. A total of 37 heat pipes made of aluminum, stainless steel and combinations of these materials were processed by various techniques, operated at different temperatures and tested at low temperature to quantitatively determine gas generation rates. In order of increasing stability are aluminum/stainless combination, all aluminum and all stainless heat pipes. One interesting result is the identification of intentionally introduced water in the ammonia during a reflux step as a means of surface passivation to reduce gas generation in stainless-steel/aluminum heat pipes.

  12. Heat pipe cooled probe

    NASA Technical Reports Server (NTRS)

    Camarda, C. J. (Inventor); Couch, L. M.

    1984-01-01

    The basic heat pipe principle is employed to provide a self-contained passively cooled probe that may be placed into a high temperature environment. The probe consists of an evaporator region of a heat pipe and a sensing instrument. Heat is absorbed as the working fluid evaporates in the probe. The vapor is transported to the vapor space of the condenser region. Heat is dissipated from the condenser region and fins causing condensation of the working fluid, which returns to the probe by gravity and the capillary action of the wick. Working fluid, wick and condenser configurations and structure materials can be selected to maintain the probe within an acceptable temperature range.

  13. Electrochemical-Thermal Modeling and Microscale Phase Change for Passive Internal Thermal Management of Lithium Ion Batteries

    NASA Astrophysics Data System (ADS)

    Bandhauer, Todd Matthew

    In the current investigation, a fully coupled electrochemical and thermal model for lithium-ion batteries is developed to investigate the effects of different thermal management strategies on battery performance. This work represents the first ever study of these coupled electrochemical-thermal phenomena in batteries from the electrochemical heat generation all the way to the dynamic heat removal in actual hybrid electric vehicles (HEV) drive cycles. In addition, a novel, passive internal cooling system that uses heat removal through liquid-vapor phase change is developed. The proposed cooling system passively removes heat almost isothermally with negligible thermal resistances between the heat source and cooling fluid, thereby allowing battery performance to improve unimpeded by thermal limitations. For the battery model, local electrochemical reaction rates are predicted using temperature-dependent data on a commercially available battery designed for high rates (C/LiFePO4) in a computationally efficient manner. Data were collected on this small battery (˜1 Ah) over a wide range of temperatures (10°C to 60°C), depths of discharge (0.15 Ah < DOD < 0.95 Ah), and rates (-5 A to 5 A) using two separate test facilities to maintain sufficient temperature fidelity and to discern the relative influence of reversible and irreversible heating. The results show that total volumetric heat generation is a primarily a function of current and DOD, and secondarily a function of temperature. The results also show that reversible heating is significant compared to irreversible heating, with a minimum of 7.5% of the total heat generation attributable to reversible heating at 5 A and 15°C. Additional tests show that these constant current data can be used to simulate the response of the battery to dynamic loading, which serves as the basis for the electrochemical-thermal model development. This model is then used to compare the effects of external and internal cooling on battery

  14. Congressionally Directed Project for Passive NOx Removal Catalysts Research

    SciTech Connect

    Schneider, William

    2014-08-29

    The Recipient proposes to produce new scientific and technical knowledge and tools to enable the discovery and deployment of highly effective materials for the selective catalytic reduction (SCR) of nitrogen oxides (NOx) from lean combustion exhaust. A second goal is to demonstrate a closely coupled experimental and computational approach to heterogeneous catalysis research. These goals will be met through the completion of four primary technical objectives: First, an in-depth kinetic analysis will be performed on two prominent classes of NOx SCR catalysts, Fe- and Cu-exchanged beta and ZSM-5 zeolites, over a wide range of catalyst formulation and under identical, high conversion conditions as a function of gas phase composition. Second, the nanoscale structure and adsorption chemistry of these high temperature (HT) and low temperature (LT) catalysts will be determined using in situ and operando spectroscopy under the same reaction conditions. Third, first-principles molecular simulations will be used to model the metal-zeolite active sites, their adsorption chemistry, and key steps in catalytic function. Fourth, this information will be integrated into chemically detailed mechanistic and kinetic descriptions and models of the operation of these well- defined NOx SCR catalysts under practically relevant reaction conditions. The new knowledge and models that derive from this work will be published in the scientific literature.

  15. KKG Group Paraffin Removal

    SciTech Connect

    Schulte, Ralph

    2001-12-01

    The Rocky Mountain Oilfield Testing Center (RMOTC) has recently completed a test of a paraffin removal system developed by the KKG Group utilizing the technology of two Russian scientists, Gennady Katzyn and Boris Koggi. The system consisting of chemical ''sticks'' that generate heat in-situ to melt the paraffin deposits in oilfield tubing. The melted paraffin is then brought to the surface utilizing the naturally flowing energy of the well.

  16. Passive Energy Building Design Tool

    Energy Science and Technology Software Center (ESTSC)

    1994-11-01

    SOLAR5 is a computer aided design tool to help architects design better, more energy efficient buildings. It is intended for use at the beginning of the design process. To get started, only four pieces of information are necessary to compute the energy needed: the square footage, the number of stories, the kind of building (such as school, home, hotel, or any one of 20 types), and its location (the program stores the temperature ranges formore » fourty major cities). Additional information may be given later to fine tune the design. An expert system using heuristics from a wide range of sources, automatically creates a passive solar baseline building from the four facts specified for that project. By modifying and adapting prior designs the user can create and work upon as many as nine schemes simultaneously. SOLAR5 can analyze the buildings thermal performance for each hour of each month and plot its total heat gain or loss as a three-dimensional surface. After reading the plot, the user can immediately redesign the building and rerun the analysis. Separate heat gain/loss surfaces can be plotted for each of the different parts of the building or schemes that add together to make up the total, including walls, roof, windows, skylights, floor, slab on grade, people, lights, equipment, and infiltration. Two different schemes can be instantly compared by asking for a three-dimensional plot showing only the difference in their performances. The objective of SOLAR5 is to allow the designer to make changes easily and quickly with detailed instantaneous pictorial feedback of the implications of the change.« less

  17. Kidney removal

    MedlinePlus

    ... will be on your side, just below the ribs or right over the lowest ribs. Muscle, fat, and tissue are cut and moved. Your surgeon may need to remove a rib to do the procedure. The tube that carries ...

  18. Spleen removal

    MedlinePlus

    ... disorders of blood cells, such as idiopathic thrombocytopenia purpura (ITP), hereditary spherocytosis , thalassemia, hemolytic anemia , and hereditary ... spherocytic anemia Hemolytic anemia Hodgkin lymphoma Idiopathic thrombocytopenic purpura (ITP) Patient Instructions Spleen removal - child - discharge Spleen ...

  19. Stable surface passivation process for compound semiconductors

    DOEpatents

    Ashby, Carol I. H.

    2001-01-01

    A passivation process for a previously sulfided, selenided or tellurated III-V compound semiconductor surface. The concentration of undesired mid-gap surface states on a compound semiconductor surface is reduced by the formation of a near-monolayer of metal-(sulfur and/or selenium and/or tellurium)-semiconductor that is effective for long term passivation of the underlying semiconductor surface. Starting with the III-V compound semiconductor surface, any oxidation present thereon is substantially removed and the surface is then treated with sulfur, selenium or tellurium to form a near-monolayer of chalcogen-semiconductor of the surface in an oxygen-free atmosphere. This chalcogenated surface is then contacted with a solution of a metal that will form a low solubility chalcogenide to form a near-monolayer of metal-chalcogen-semiconductor. The resulting passivating layer provides long term protection for the underlying surface at or above the level achieved by a freshly chalcogenated compound semiconductor surface in an oxygen free atmosphere.

  20. Fundamental studies of passivity and passivity breakdown. Final report

    SciTech Connect

    Macdonald, D.D.; Urquidi-Macdonald, M.; Song, H.; Biaggio-Rocha, S.; Searson, P.

    1991-11-01

    This report summarizes the findings of our fundamental research program on passivity and passivity breakdown. During the past three and one half years in this program (including the three year incrementally-funded grant prior to the present grant), we developed and experimentally tested various physical models for the growth and breakdown of passive films on metal surfaces. These models belong to a general class termed ``point defects models`` (PDMs), in which the growth and breakdown of passive films are described in terms of the movement of anion and cation vacancies.

  1. Passive propellant system

    NASA Technical Reports Server (NTRS)

    Hess, D. A.; Regnier, W. W.; Jacobs, V. L. (Inventor)

    1979-01-01

    A passive propellant acquisition and feed system is disclosed which acquires and feeds gas-free propellant in low or zero-g environments during orbital maneuvers and retains this propellant under high axially directed acceleration such as may be experienced during launch of a space vehicle and orbit-to-orbit transfer is described. The propellant system includes a dual compartment propellant tank with independent surface tension acquisition channels in each compartment to provide gas-free flow of pressurized liquid propellant from one compartment to the other in one direction only.

  2. Passive Immunization Against Poliomyelitis

    PubMed Central

    Rinaldo, Charles R.

    2005-01-01

    Poliomyelitis has gone from being one of the worst scourges of the 20th century to nearing eradication in the 21st. This success is well known to be attributable to the Salk inactivated and Sabin attenuated poliovirus vaccines. However, before introduction of these vaccines, William McDowall Hammon of the University of Pittsburgh Graduate School of Public Health led the first major breakthrough in prevention of the disease by using passive immunization in one of the earliest double-blind, placebo-controlled clinical trials. This study provided the first evidence that antibodies to poliovirus could prevent the disease in humans. PMID:15855454

  3. Tattoo removal.

    PubMed

    Adatto, Maurice A; Halachmi, Shlomit; Lapidoth, Moshe

    2011-01-01

    Over 50,000 new tattoos are placed each year in the United States. Studies estimate that 24% of American college students have tattoos and 10% of male American adults have a tattoo. The rising popularity of tattoos has spurred a corresponding increase in tattoo removal. Not all tattoos are placed intentionally or for aesthetic reasons though. Traumatic tattoos due to unintentional penetration of exogenous pigments can also occur, as well as the placement of medical tattoos to mark treatment boundaries, for example in radiation therapy. Protocols for tattoo removal have evolved over history. The first evidence of tattoo removal attempts was found in Egyptian mummies, dated to have lived 4,000 years BC. Ancient Greek writings describe tattoo removal with salt abrasion or with a paste containing cloves of white garlic mixed with Alexandrian cantharidin. With the advent of Q-switched lasers in the late 1960s, the outcomes of tattoo removal changed radically. In addition to their selective absorption by the pigment, the extremely short pulse duration of Q-switched lasers has made them the gold standard for tattoo removal. PMID:21865802

  4. Correction of magnetization sextupole and decapole in a 5 centimeter bore SSC dipole using passive superconductor

    SciTech Connect

    Green, M.A.

    1991-05-01

    Higher multipoles due to magnetization of the superconductor in four and five centimeter bore Superconducting Super Collider (SSC) superconducting dipole magnets have been observed. The use of passive superconductor to correct out the magnetization sextupole has been demonstrated on two dipoles built by the Lawrence Berkeley Laboratory (LBL). This reports shows how passive correction can be applied to the five centimeter SSC dipoles to remove sextupole and decapole caused by magnetization of the dipole superconductor. Two passive superconductor corrector options will be presented. The change in magnetization sextupole and decapole due to flux creep decay of the superconductor during injection can be partially compensated for using the passive superconductor. 9 refs; 5 figs.

  5. Sulfidic photochemical passivation of GaAs surfaces in alcoholic solutions

    SciTech Connect

    Simonsmeier, T.; Ivankov, A.; Bauhofer, W.

    2005-04-15

    We report on a remarkable enhancement of the passivation effect of sulfidic solutions through illumination with above band gap light. Luminescence measurements on GaAs surfaces which have been illuminated during chemical passivation reveal in comparison to nonilluminated samples a further reduction of their surface density of states as well as a significantly increased stability of the passivation. Investigations with photoelectron spectroscopy show that illumination leads to a nearly complete removal of oxides on the surface. Measurements on Schottky diodes which have been manufactured with photochemically passivated GaAs indicate a noticeable decrease in band bending and a depinning of the Fermi level.

  6. Steam turbine: Alternative emergency drive for the secure removal of residual heat from the core of light water reactors in ultimate emergency situation

    SciTech Connect

    Souza Dos Santos, R.

    2012-07-01

    In 2011 the nuclear power generation has suffered an extreme probation. That could be the meaning of what happened in Fukushima Nuclear Power Plants. In those plants, an earthquake of 8.9 on the Richter scale was recorded. The quake intensity was above the trip point of shutting down the plants. Since heat still continued to be generated, the procedure to cooling the reactor was started. One hour after the earthquake, a tsunami rocked the Fukushima shore, degrading all cooling system of plants. Since the earthquake time, the plant had lost external electricity, impacting the pumping working, drive by electric engine. When operable, the BWR plants responded the management of steam. However, the lack of electricity had degraded the plant maneuvers. In this paper we have presented a scheme to use the steam as an alternative drive to maintain operable the cooling system of nuclear power plant. This scheme adds more reliability and robustness to the cooling systems. Additionally, we purposed a solution to the cooling in case of lacking water for the condenser system. In our approach, steam driven turbines substitute electric engines in the ultimate emergency cooling system. (authors)

  7. Formation of a passivating CH3NH3PbI3/PbI2 interface during moderate heating of CH3NH3PbI3 layers

    NASA Astrophysics Data System (ADS)

    Supasai, T.; Rujisamphan, N.; Ullrich, K.; Chemseddine, A.; Dittrich, Th.

    2013-10-01

    Layers of CH3NH3PbI3 are investigated by modulated surface photovoltage spectroscopy (SPV) during heating in vacuum. As prepared CH3NH3PbI3 layers behave as a p-type doped semiconductor in depletion with a band gap of 1.5 eV. After heating to 140 °C the sign of the SPV signals of CH3NH3PbI3 changed concomitant with the appearance of a second band gap at 2.36 eV ascribed to PbI2, and SPV signals related to charge separation from defect states were reduced after moderate heating.

  8. Deployable Heat Pipe Radiator

    NASA Technical Reports Server (NTRS)

    Edelstein, F.

    1975-01-01

    A 1.2- by 1.8-m variable conductance heat pipe radiator was designed, built, and tested. The radiator has deployment capability and can passively control Freon-21 fluid loop temperatures under varying loads and environments. It consists of six grooved variable conductance heat pipes attached to a 0.032-in. aluminum panel. Heat is supplied to the radiator via a fluid header or a single-fluid flexible heat pipe header. The heat pipe header is an artery design that has a flexible section capable of bending up to 90 degrees. Radiator loads as high as 850 watts were successfully tested. Over a load variation of 200 watts, the outlet temperature of the Freon-21 fluid varied by 7 F. An alternate control system was also investigated which used a variable conductance heat pipe header attached to the heat pipe radiator panel.

  9. Passive Solar Commercial Demonstration Program: Phase I. Final report

    SciTech Connect

    1981-02-10

    The passive solar retrofit of a small existing commercial/residential building is described. An add on gallery/sunspace is integrated into the existing structure both in terms of energy and architectural functioning. The sunspace solution maximizes the amount of south facing glass for solar heat gain, while still allowing a deep penetration of daylight into the existing buildings. (MHR)

  10. Passive field reflectance measurements

    NASA Astrophysics Data System (ADS)

    Weber, Christian; Schinca, Daniel C.; Tocho, Jorge O.; Videla, Fabian

    2008-10-01

    The results of reflectance measurements performed with a three-band passive radiometer with independent channels for solar irradiance reference are presented. Comparative operation between the traditional method that uses downward-looking field and reference white panel measurements and the new approach involving duplicated downward- and upward-looking spectral channels (each latter one with its own diffuser) is analyzed. The results indicate that the latter method performs in very good agreement with the standard method and is more suitable for passive sensors under rapidly changing atmospheric conditions (such as clouds, dust, mist, smog and other scatterers), since a more reliable synchronous recording of reference and incident light is achieved. Besides, having separate channels for the reference and the signal allows a better balancing of gains in the amplifiers for each spectral channel. We show the results obtained in the determination of the normalized difference vegetation index (NDVI) corresponding to the period 2004-2007 field experiments concerning weed detection in soybean stubbles and fertilizer level assessment in wheat. The method may be used to refine sensor-based nitrogen fertilizer rate recommendations and to determine suitable zones for herbicide applications.

  11. Passive bistatic radar analysis

    NASA Astrophysics Data System (ADS)

    O'Hagan, Daniel W.; Kuschel, H.; Schiller, Joachim

    2009-06-01

    Passive Bistatic Radar (PBR) research is at its zenith with several notable PBR systems currently operational, or available for deployment. Such PBRs include the Manastash Ridge Radar (MRR) developed for and by academia; Silent Sentry developed as a commercial concern by Lockheed Martin; and Homeland Alerter (HA100) also a commercial system developed by Thales. However at present, despite the existence of numerous PBR prototypes, take up of commercial passive radar technology remains slow. This is due in part to technology immaturity, in part to politics, and particularly due to the fact that monostatic radars perform so well. If PBRs are to enjoy longevity as a viable technology then it is imperative that they address certain niche application areas, with the aforementioned MRR being one prime example of this. The focus of this paper will be an analysis of a PBR system that utilised FM radio signals of opportunity to detect aircraft targets with an RCS generally not lower than 20 m2. The paper will demonstrate the theoretical detection coverage of an FM based PBR operating in a severe interference environment.

  12. Mechanical passive logic module

    NASA Astrophysics Data System (ADS)

    Chattopadhyay, Tanay; Caulfield, H. John

    2015-02-01

    Nothing from nothing gives simple simile, but something from nothing is an interesting and challenging task. Adolf Lohmann once proposed 'do nothing machine' in optics, which only copies input to output. Passive logic module (PALM) is a special type of 'do nothing machine' which can converts inputs into one of 16 possible binary outputs. This logic module is not like the conventional irreversible one. It is a simple type of reversible Turing machine. In this manuscript we discussed and demonstrated PALM using mechanical movement of plane mirrors. Also we discussed the theoretical model of micro electro mechanical system (MEMS) based PALM in this manuscript. It may have several valuable properties such as passive operation (no need for nonlinear elements as other logic device require) and modular logic (one device implementing any Boolean logic function with simple internal changes). The result is obtained from the demonstration by only looking up the output. No calculation is required to get the result. Not only that, PALM is a simple type of the famous 'billiard ball machine', which also discussed in this manuscript.

  13. Volcanic passive margins

    NASA Astrophysics Data System (ADS)

    Geoffroy, Laurent

    2005-12-01

    Compared to non-volcanic ones, volcanic passive margins mark continental break-up over a hotter mantle, probably subject to small-scale convection. They present distinctive genetic and structural features. High-rate extension of the lithosphere is associated with catastrophic mantle melting responsible for the accretion of a thick igneous crust. Distinctive structural features of volcanic margins are syn-magmatic and continentward-dipping crustal faults accommodating the seaward flexure of the igneous crust. Volcanic margins present along-axis a magmatic and tectonic segmentation with wavelength similar to adjacent slow-spreading ridges. Their 3D organisation suggests a connection between loci of mantle melting at depths and zones of strain concentration within the lithosphere. Break-up would start and propagate from localized thermally-softened lithospheric zones. These 'soft points' could be localized over small-scale convection cells found at the bottom of the lithosphere, where adiabatic mantle melting would specifically occur. The particular structure of the brittle crust at volcanic passive margins could be interpreted by active and sudden oceanward flow of both the unstable hot mantle and the ductile part of the lithosphere during the break-up stage. To cite this article: L. Geoffroy, C. R. Geoscience 337 (2005).

  14. Passive-solar construction handbook

    SciTech Connect

    Levy, E.; Evans, D.; Gardstein, C.

    1981-02-01

    Many of the basic elements of passive solar design are reviewed. Passive solar construction is covered according to system type, each system type discussion including a general discussion of the important design and construction issues which apply to the particular system and case studies illustrating designed and built examples of the system type. The three basic types of passive solar systems discussed are direct gain, thermal storage wall, and attached sunspace. Thermal performance and construction information is presented for typical materials used in passive solar collector components, storage components, and control components. Appended are an overview of analysis methods and a technique for estimating performance. (LEW)

  15. SBWR design update: Passively safe, nuclear power generation for the twenty first century

    SciTech Connect

    Upton, H.A.; Torbeck, J.E.; Billig, P.F.; Duncan, J.D.; Herzog, M.

    1996-07-01

    This paper describes the current state of design, development and testing of a new generation of Boiling Water Reactors, the SBWR. The SBWR is a plant that will be significantly simpler to build, operate and maintain compared to operating plants. In this paper, the design and performance of the reference 670 MWe SBWR is summarized, the economics of SBWR power generation is addressed and the current developments in component testing and integrated system testing are given. This paper specifically discusses the current innovations and key reference design features of the SBWR including the RPV, depressurization system, pressure suppression system, flammability control system (based on passive autocatalytic recombiners), gravity driven cooling system, the passive containment cooling system, isolation condenser system and other unique engineered safety features that rely on gravity or stored energy to ensure core cooling, decay heat removal, and ATWS mitigation. The component and integrated system development testing summarized includes key results of recently concluded PANTHERS condenser tests conducted at SIET in Italy, GIRAFFE non-condensable gas testing by Toshiba in Japan, and the ongoing testing at the PANDA facility at PSI in Switzerland.

  16. Advanced Coating Removal Techniques

    NASA Technical Reports Server (NTRS)

    Seibert, Jon

    2006-01-01

    An important step in the repair and protection against corrosion damage is the safe removal of the oxidation and protective coatings without further damaging the integrity of the substrate. Two such methods that are proving to be safe and effective in this task are liquid nitrogen and laser removal operations. Laser technology used for the removal of protective coatings is currently being researched and implemented in various areas of the aerospace industry. Delivering thousands of focused energy pulses, the laser ablates the coating surface by heating and dissolving the material applied to the substrate. The metal substrate will reflect the laser and redirect the energy to any remaining protective coating, thus preventing any collateral damage the substrate may suffer throughout the process. Liquid nitrogen jets are comparable to blasting with an ultra high-pressure water jet but without the residual liquid that requires collection and removal .As the liquid nitrogen reaches the surface it is transformed into gaseous nitrogen and reenters the atmosphere without any contamination to surrounding hardware. These innovative technologies simplify corrosion repair by eliminating hazardous chemicals and repetitive manual labor from the coating removal process. One very significant advantage is the reduction of particulate contamination exposure to personnel. With the removal of coatings adjacent to sensitive flight hardware, a benefit of each technique for the space program is that no contamination such as beads, water, or sanding residue is left behind when the job is finished. One primary concern is the safe removal of coatings from thin aluminum honeycomb face sheet. NASA recently conducted thermal testing on liquid nitrogen systems and found that no damage occurred on 1/6", aluminum substrates. Wright Patterson Air Force Base in conjunction with Boeing and NASA is currently testing the laser remOval technique for process qualification. Other applications of liquid

  17. Detroit Edison's Fermi 1 - Preparation for Reactor Removal

    SciTech Connect

    Swindle, Danny

    2008-01-15

    This paper is intended to provide information about the ongoing decommissioning tasks at Detroit Edison's Fermi 1 plant, and in particular, the work being performed to prepare the reactor for removal and disposal. In 1972 Fermi 1 was shutdown and the fuel returned to the Atomic Energy Commission. By the end of 1975, a retirement plan was prepared, the bulk sodium removed, and the plant placed in a safe store condition. The plant systems were left isolated with the sodium containing systems inert with carbon dioxide in an attempt to form a carbonate layer, thus passivating the underlying reactive sodium. In 1996, Detroit Edison determined to evaluate the condition of the plant and to make recommendations in relation to the Fermi 1 future plans. At the end of 1997 approval was obtained to remove the bulk asbestos and residual alkali-metals (i.e., sodium and sodium potassium (NaK)). In 2000, full nuclear decommissioning of the plant was approved. To date, the bulk asbestos insulation has been removed, and the only NaK remaining is located in six capillary instrument tubes. The remaining sodium is contained within the reactor, two of the three primary loops, and miscellaneous removed pipes and equipment to be processed. The preferred method for removing or reacting sodium at Fermi 1 is by injecting superheated steam into a heated, nitrogen inert system. The byproducts of this reaction are caustic sodium hydroxide, hydrogen gas, and heat. The decision was made to separate the three primary loops from the reactor for better control prior to processing each loop and the reactor separately. The first loop has already been processed. The main focus is now to process the reactor to allow removal and disposal of the Class C waste prior to the anticipated June 2008 closure of the Barnwell radioactive waste disposal facility located in South Carolina. Lessons learnt are summarized and concern: the realistic schedule and adherence to the schedule, time estimates, personnel

  18. Radiation detector system having heat pipe based cooling

    DOEpatents

    Iwanczyk, Jan S.; Saveliev, Valeri D.; Barkan, Shaul

    2006-10-31

    A radiation detector system having a heat pipe based cooling. The radiation detector system includes a radiation detector thermally coupled to a thermo electric cooler (TEC). The TEC cools down the radiation detector, whereby heat is generated by the TEC. A heat removal device dissipates the heat generated by the TEC to surrounding environment. A heat pipe has a first end thermally coupled to the TEC to receive the heat generated by the TEC, and a second end thermally coupled to the heat removal device. The heat pipe transfers the heat generated by the TEC from the first end to the second end to be removed by the heat removal device.

  19. Impact of Passive Safety on FHR Instrumentation Systems Design and Classification

    SciTech Connect

    Holcomb, David Eugene

    2015-01-01

    Fluoride salt-cooled high-temperature reactors (FHRs) will rely more extensively on passive safety than earlier reactor classes. 10CFR50 Appendix A, General Design Criteria for Nuclear Power Plants, establishes minimum design requirements to provide reasonable assurance of adequate safety. 10CFR50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors, provides guidance on how the safety significance of systems, structures, and components (SSCs) should be reflected in their regulatory treatment. The Nuclear Energy Institute (NEI) has provided 10 CFR 50.69 SSC Categorization Guideline (NEI-00-04) that factors in probabilistic risk assessment (PRA) model insights, as well as deterministic insights, through an integrated decision-making panel. Employing the PRA to inform deterministic requirements enables an appropriately balanced, technically sound categorization to be established. No FHR currently has an adequate PRA or set of design basis accidents to enable establishing the safety classification of its SSCs. While all SSCs used to comply with the general design criteria (GDCs) will be safety related, the intent is to limit the instrumentation risk significance through effective design and reliance on inherent passive safety characteristics. For example, FHRs have no safety-significant temperature threshold phenomena, thus enabling the primary and reserve reactivity control systems required by GDC 26 to be passively, thermally triggered at temperatures well below those for which core or primary coolant boundary damage would occur. Moreover, the passive thermal triggering of the primary and reserve shutdown systems may relegate the control rod drive motors to the control system, substantially decreasing the amount of safety-significant wiring needed. Similarly, FHR decay heat removal systems are intended to be running continuously to minimize the amount of safety-significant instrumentation needed to initiate

  20. Incorporation of Passive Safety Systems in the Generation-IV Multi-Application Small Light Water Reactor (MASLWR)

    SciTech Connect

    Modro, S. Michael; Ougouag, Abderrafi M.; Fisher, James; Weaver, Kevan

    2002-07-01

    The Idaho National Engineering and Environmental Laboratory (INEEL), Nexant Inc. and the Oregon State University (OSU) developed an innovative Multi-Application Small Light Water Reactor (MASLWR) concept. The MASLWR is a small, modular, safe, and economic natural circulation light water reactor developed with the primary goal of producing electric power, but with the flexibility to be used for water desalination or district heating with deployment in a variety of locations. The MASLWR was developed, by design, to be a safe and economic reactor concept that can be deployed in the near term by utilizing current experience and capabilities of the industry. The key features of the MASLWR concept are the extreme simplicity of the design and its passive safety systems. This paper provides an overview of safety analyses performed for the MASLWR concept and explores potential for the increase in passive safety via the implementation of new features. The results of these safety studies demonstrate that the reactor core will be provided with a stable cooling source adequate to remove decay heat without significant cladding heatup under all credible scenarios. The response of the system to accident conditions is a controlled depressurization, whereby most of the primary system blowdown occurs via the submerged ADS blowdown pathway. (authors)

  1. Commentary on "Capturing the Evasive Passive"

    ERIC Educational Resources Information Center

    Lillo-Martin, Diane; Snyder, William

    2009-01-01

    Passives has been the focus of much research in language acquisition since the 1970s. It has been clear from this research that young children seldom produce passives spontaneously, particularly "long" or "full" passives with a by-phrase; and they usually perform poorly on experimental tests of the comprehension of passives, especially passives of…

  2. Heat transfer system

    DOEpatents

    McGuire, Joseph C.

    1982-01-01

    A heat transfer system for a nuclear reactor. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.

  3. Heat transfer system

    DOEpatents

    Not Available

    1980-03-07

    A heat transfer system for a nuclear reactor is described. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.

  4. Passive magnetic bearing system

    DOEpatents

    Post, Richard F.

    2014-09-02

    An axial stabilizer for the rotor of a magnetic bearing provides external control of stiffness through switching in external inductances. External control also allows the stabilizer to become a part of a passive/active magnetic bearing system that requires no external source of power and no position sensor. Stabilizers for displacements transverse to the axis of rotation are provided that require only a single cylindrical Halbach array in its operation, and thus are especially suited for use in high rotation speed applications, such as flywheel energy storage systems. The elimination of the need of an inner cylindrical array solves the difficult mechanical problem of supplying support against centrifugal forces for the magnets of that array. Compensation is provided for the temperature variation of the strength of the magnetic fields of the permanent magnets in the levitating magnet arrays.

  5. Passive containment cooling system

    DOEpatents

    Billig, P.F.; Cooke, F.E.; Fitch, J.R.

    1994-01-25

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA. 1 figure.

  6. Passive Ball Capture Joint

    NASA Technical Reports Server (NTRS)

    Cloyd, Richard A. (Inventor); Bryan, Thomas C. (Inventor)

    2003-01-01

    A passive ball capture joint has a sleeve with a plurality of bores distributed about a circumference thereof and formed therethrough at an acute angle relative to the sleeve's longitudinal axis. A spring-loaded retainer is slidingly fitted in each bore and is biased such that, if allowed, will extend at least partially into the sleeve to retain a ball therein. A ring, rotatably mounted about the bores, has an interior wall defining a plurality of shaped races that bear against the spring-loaded retainers. A mechanized rotational force producer is coupled to the ring. The ring can be rotated from a first position (that presses the retainers into the sleeve to lock the ball in place) to a second position (that allows the retainers to springback out of the sleeve to release the ball).

  7. Passive containment cooling system

    DOEpatents

    Billig, Paul F.; Cooke, Franklin E.; Fitch, James R.

    1994-01-01

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA.

  8. Heating/daylighting prototype development. Phase I, Passive and Hybrid Solar Manufactured Building Project. Interim report and project status report No. 1, 1 October 1979-29 February 1980

    SciTech Connect

    Snyder, M.; Fraker, H.; Lindsey, L.; Braham, W.; Hallagan, W.; Huffman, J.

    1980-03-31

    Climatological data, both representative (typical) and extreme conditions, relevant to building energy use in Grandview, Missouri are presented. The energy-related characteristics of a particular building and its use are merged with ambient weather conditions. The graphs depict daily fluctuations in the major categories of building heating/cooling load for the experimental building (Roof Runner facility) at Butler Research Center. Data input include hourly weather and building occupancy schedules, the geometry and fixed thermal characteristics (component R-values, heat capacities, etc.) of the prototype structure, and variable conditions (status of moveable insulating shutters, HVAC operating modes, etc.). The prototype systems to be incorporated in the new Roof Runner building are shown. Both warehouse (no ceiling) and office (suspended ceiling) system types are included. The diagrams conceptually depict the heat flows in several representative operating modes, sampling the wide variety of operating conditions which will be evaluated during the testing phase of this project. Cost estimates for the designs selected for construction are provided. (MHR)

  9. ARSENIC REMOVAL

    EPA Science Inventory

    Presentation covered five topics; arsenic chemistry, best available technology (BAT), surface water technology, ground water technology and case studies of arsenic removal. The discussion on arsenic chemistry focused on the need and method of speciation for AsIII and AsV. BAT me...

  10. Splinter removal

    MedlinePlus

    ... remove a splinter, first wash your hands with soap and water. Use tweezers to grab the splinter. Carefully pull it out at the same angle it went in. If the splinter is under the skin or hard to grab: Sterilize a pin or needle by ...

  11. REMOVING INORGANICS

    EPA Science Inventory

    When EPA sets a regulation ( a maxim contaminant level) for a contaminant, it must also specify the "best available technology" (BAT) that can be used to remove the contaminant. ecause the regulations apply to community water systems, the technologies selected are ones that are c...

  12. Locally contacted rear surface passivated solar cells by inkjet printing

    NASA Astrophysics Data System (ADS)

    Phiwpha, N.; Fangsuwannarak, T.; Sopitpan, S.

    2014-06-01

    Inkjet printing of photoresist material may provide a new route for low-cost fabrication of patterned oxide passivation layer of solar cells that require fine patterning and simple process. However, printing by liquid-based, environmentally friendly ink and printing device required development efforts aimed at achieving a fine patterning and long used inkjet nozzles under corrosive influence. This work was demonstrated a concept for grooved silicon oxide patterning for rear localized contact of p-n junction solar cells by chemical etching after photoresist patterning obtained. This article reviews the silicon dioxide fabrication on p-Si substrate from sol-gel technique for oxide passivation layer of solar cells. The aluminium was deposited on the patterned oxide layer and then heated at its Al-Si eutectic temperature. Finally, an aluminium-induced solid-phase epitaxial growth of p+ forming into the openings of the oxide passivation layer was presented. The sheet resistance of n-emitter layer, carrier life-time and surface recombination velocity values are investigated. Photoconductive measurements were performed on the prepared samples after each thermal process to measure the effective lifetime of the minority carriers. Carrier lifetime up to 60 microseconds has been measured on c-Si wafer passivated by the opened SiO2 layer. It was shown that the patterned SiO2 passivation has obtained high passivation quality making by the proposed inkjet printing method.

  13. Hydrophobic liquid/gas separator for heat pipes

    NASA Technical Reports Server (NTRS)

    Marcus, B. D.

    1972-01-01

    Perforated nonwetting plug of material such as polytetrafluoroethylene is mounted in gas reservoir feed tube, preferably at end which extends into heat pipe condenser section, to prevent liquid from entering gas reservoir of passively controlled heat pipe.

  14. A XPS study of the Mo effect on passivation behaviors for highly controlled stainless steels in neutral and alkaline conditions

    NASA Astrophysics Data System (ADS)

    Mesquita, Thiago J.; Chauveau, Eric; Mantel, Marc; Nogueira, Ricardo P.

    2013-04-01

    The objective of this work is to study the effect of Mo additions on film passive properties of three different stainless steels (SS) types (austenitic, ferritic and duplex alloys). A comparison between Mo containing (3 wt% Mo) and free Mo (0 wt% Mo) grades of highly controlled laboratory heats was done considering their passive film formed in different aggressive conditions, from neutral to alkaline pH. The presence of oxidized Mo on the passive layer was confirmed by X-ray photoelectron Spectroscopy (XPS). The presence of Mo within the passive film improved the passivity breakdown potential for the duplex and ferritic SS, but seemed to have no effect for austenitic SS.

  15. Simulation of a passive solar energy system. Master's thesis

    SciTech Connect

    Slate, M.P.

    1982-12-01

    A simple lumped capacitance-resistance model is used to simulate heat flow in a residential size structure heated passively by the sun. The model takes the form of an analogous electrical circuit. A computer program was written to analyse the circuit. By altering the input parameters of the program, the thermal performance of a wide variety of passive solar designs can be investigated for any geographical location. By comparing program generated data to data taken from experimental test cells in Los Alamos, New Mexico, it was found that the simulation program predicted energy use to within 4 percent of measured values. Also, the computer program predicted temperature swings to within 16 percent of measured swings. Correlation with empirical methods of calculating monthly and annual savings in fuel use for heating was poor. Using the simulation calculations as a base, the predictions of anual savings differed by as much as 76 percent.

  16. Hood River Passive House, Hood River, Oregon (Fact Sheet)

    SciTech Connect

    Not Available

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  17. Antireflection/Passivation Step For Silicon Cell

    NASA Technical Reports Server (NTRS)

    Crotty, Gerald T.; Kachare, Akaram H.; Daud, Taher

    1988-01-01

    New process excludes usual silicon oxide passivation. Changes in principal electrical parameters during two kinds of processing suggest antireflection treatment almost as effective as oxide treatment in passivating cells. Does so without disadvantages of SiOx passivation.

  18. Advanced heat pump

    NASA Astrophysics Data System (ADS)

    Ashley, Joseph L.; Matthews, John D.

    1989-09-01

    This patent application discloses a heat pump which includes a first packed bed of liquid desiccant for removing moisture from outside air in the heating mode of operation, and a pump for transferring the moisture laden desiccant to a second packed bed which humidifies condenser heated inside air by adding water vapor to the air. The first packed bed, by removing moisture from the outside air before it passes through the heat pump's evaporator coils, prevents frost from forming on the coils. In the cooling mode of operation the second packed bed of liquid desiccant removes water vapor from the air inside of the building. The moisture laden desiccant is then transferred to the first packed bed by a second pump where condenser heat transfers the moisture from the desiccant to outside air.

  19. Passive-solar retrofit study for the United States Navy

    SciTech Connect

    Wray, W.O.; Miles, C.R.

    1981-01-01

    A passive solar retrofit study has been conducted for the United States Navy at the Los Alamos National Laboratory. The purpose of the study was to determine the energy savings obtainable in concrete block buildings from several passive solar heating strategies. A procedure involving the use of test cell data and computer simulation was employed to assess the merits of six retrofit options. The six strategies selected were chosen on the basis of providing a series of options that will deliver increasing energy savings at the cost of correspondingly increased levels of commitment.

  20. Passive-solar-retrofit study for the United States Navy

    SciTech Connect

    Wray, W.O.; Miles, C.R.

    1981-01-01

    A passive solar retrofit study has been conducted for the United States Navy at the Los Alamos National Laboratory. The purpose of the study was to determine the energy savings obtainable in concrete block buildings from several passive solar heating strategies. A procedure involving the use of test cell data and computer simulation was employed to assess the merits of six retrofit options. The six strategies selected were chosen on the basis of providing a series of options that will deliver increasing energy savings at the cost of correspondingly increased levels of commitment.