Sample records for phosphate bowel preparation

  1. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation

    PubMed Central

    Tongprasert, Sasinee; Sobhonslidsuk, Abhasnee; Rattanasiri, Sasivimol

    2009-01-01

    AIM: To evaluate the effectiveness of simethicone in enhancing visibility and efficacy during colonoscopy. METHODS: A prospective, double-blind, randomized, placebo-controlled study was conducted. One hundred and twenty-four patients were allocated to receive 2 doses of sodium phosphate plus 240 mg of tablet simethicone or placebo as bowel preparation. Visibility was blindly assessed for the amount of air bubbles and adequacy of colon preparation. Total colonoscopic time, side effects of the medication, endoscopist and patient satisfaction were also compared. RESULTS: Sodium phosphate plus simethicone, compared to sodium phosphate plus placebo, improved visibility by diminishing air bubbles (100.00% vs 42.37%, P < 0.0001) but simethicone failed to demonstrate improvement in adequacy of colon preparation (90.16% vs 81.36%, P = 0.17). Endoscopist and patient satisfaction were increased significantly in the simethicone group. However, there was no difference in the total duration of colonoscopy and side effects of the medication. CONCLUSION: The addition of simethicone is of benefit for colonoscopic bowel preparation by diminishing air bubbles, which results in enhanced visibility. Endoscopist and patient satisfaction is also increased. PMID:19554657

  2. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation.

    PubMed

    Tongprasert, Sasinee; Sobhonslidsuk, Abhasnee; Rattanasiri, Sasivimol

    2009-06-28

    To evaluate the effectiveness of simethicone in enhancing visibility and efficacy during colonoscopy. A prospective, double-blind, randomized, placebo-controlled study was conducted. One hundred and twenty-four patients were allocated to receive 2 doses of sodium phosphate plus 240 mg of tablet simethicone or placebo as bowel preparation. Visibility was blindly assessed for the amount of air bubbles and adequacy of colon preparation. Total colonoscopic time, side effects of the medication, endoscopist and patient satisfaction were also compared. Sodium phosphate plus simethicone, compared to sodium phosphate plus placebo, improved visibility by diminishing air bubbles (100.00% vs 42.37%, P < 0.0001) but simethicone failed to demonstrate improvement in adequacy of colon preparation (90.16% vs 81.36%, P = 0.17). Endoscopist and patient satisfaction were increased significantly in the simethicone group. However, there was no difference in the total duration of colonoscopy and side effects of the medication. The addition of simethicone is of benefit for colonoscopic bowel preparation by diminishing air bubbles, which results in enhanced visibility. Endoscopist and patient satisfaction is also increased.

  3. Massive hyperphosphatemia in a patient with neuronal intestinal dysplasia after bowel preparation with oral sodium phosphate.

    PubMed

    Arikan, Hakki; Guler, Derya; Birdal, Gurdal; Nalcaci, Serdar; Aykut, Emre; Ozcan, Ceren; Irmak, Rahmi; Banzragch, Munkhtsetseg; Arzu, Velioglu

    2013-07-01

    Oral sodium phosphate-based laxatives are frequently used for bowel preparation or relief of constipation in some countries. However, these agents are not without risk. Small and clinical insignificant increments on serum phosphorus levels are observed in almost all individuals after use of oral sodium phosphate. Some patients are prone to severe hyperphosphatemia such as elders, those with chronic or acute renal disease and those with poor bowel motility. Severe hyperphosphatemia accompanied with hypocalcemia may be life-threatening in these patients. We present an 18-year-old woman with neuronal intestinal dysplasia who developed symptomatic and severe hyperphosphatemia after bowel preparation with oral sodium phosphate enema. Urgent hemodialysis was performed two times for severe hyperphosphatemia.

  4. Optimal Bowel Preparation for Video Capsule Endoscopy

    PubMed Central

    Song, Hyun Joo; Moon, Jeong Seop; Shim, Ki-Nam

    2016-01-01

    During video capsule endoscopy (VCE), several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG-) based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE. PMID:26880894

  5. Feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy.

    PubMed

    Zhou, Jieqiong; Tang, Xiaowei; Wang, Jing; Chen, Zhenyu; Wang, Xinying; Jiang, Bo

    2017-08-01

    Bowel preparation regimens for colon capsule endoscopy are not yet standardized since they are not well optimized. The aim of the present study was to evaluate the feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy. A total of 31 patients were prospectively enrolled. In the novel regimen, on the day prior to examination, a low-fiber diet was permitted, 5 mg mosapride citrate was administered twice (1 h prior to lunch and supper) and 1 l polyethylene glycol was administered in the evening. On the day of the examination, an additional 1 l polyethylene glycol, 5 mg mosapride citrate and 200 mg simethicone were administered before capsule ingestion. Polyethylene glycol booster (0.5 l) was administered twice, at 1 and 4 h following capsule ingestion. Colon cleansing levels, ileocecal valve transit time and completion rate were evaluated. A total of 29 patients were included in the final analysis, 90% of whom achieved adequate preparation of the overall colon. Ileocecal valve transit time was 2.35±0.82 h and completion rate was 79.3%. The results revealed that the novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy was feasible, with adequate colon cleansing and completion rates, and has the potential to be used as an alternative regimen.

  6. Comparative study of two bowel preparation regimens for colonoscopy: senna tablets vs sodium phosphate solution.

    PubMed

    Kositchaiwat, Savit; Suwanthanmma, Weerapat; Suvikapakornkul, Ronnarat; Tiewthanom, Vaewvadee; Rerkpatanakit, Prisna; Tinkornrusmee, Chaowalitr

    2006-09-14

    To compare the efficacy and acceptance of senna tablet and sodium phosphate solution for bowel preparation before colonoscopy. One hundred and thirty four patients, who needed elective colonoscopy, were randomly allocated to take 180 mg senna tablet or 95 mL sodium phosphate solution on the day before colonoscopy. The efficacies of both laxatives were compared using the mean difference of colon-cleanliness score of the rectum, sigmoid segments, descending colon, transverse colon and cecum. The scores were rated by two observers who were blinded to the laxatives administered. The higher score means that the colon is cleaner. The efficacy of both laxatives were equivalent if the 95% confidence interval of the mean difference of the score of colon lie within -1 to +1. On intention-to-treat analysis, the mean cleanliness scores in the four segments of colon except the cecum were higher in the sodium phosphate group than those in senna group (7.9 +/- 1.7 vs 8.3 +/- 1.5, 8.0 +/- 1.8 vs 8.5 +/- 1.4, 7.9 +/- 2.0 vs 8.5 +/- 1.3, 7.9 +/- 2.0 vs 8.2 +/- 1.4 and 7.2 +/- 1.7 vs 6.9 +/- 1.4, respectively). The 95% confidence intervals (95% CI) of mean difference in each segment of colon were not found to lie within 1 point which indicated that their efficacies were not equivalent. The taste of senna was better than sodium phosphate solution. Also, senna had fewer side effects. The efficacy of senna is not equivalent to sodium phosphate solution in bowel preparation for colonoscopy, but senna may be considered an alternative laxative.

  7. Achieving the best bowel preparation for colonoscopy

    PubMed Central

    Parra-Blanco, Adolfo; Ruiz, Alex; Alvarez-Lobos, Manuel; Amorós, Ana; Gana, Juan Cristóbal; Ibáñez, Patricio; Ono, Akiko; Fujii, Takahiro

    2014-01-01

    Bowel preparation is a core issue in colonoscopy, as it is closely related to the quality of the procedure. Patients often find that bowel preparation is the most unpleasant part of the examination. It is widely accepted that the quality of cleansing must be excellent to facilitate detecting neoplastic lesions. In spite of its importance and potential implications, until recently, bowel preparation has not been the subject of much study. The most commonly used agents are high-volume polyethylene glycol (PEG) electrolyte solution and sodium phosphate. There has been some confusion, even in published meta-analyses, regarding which of the two agents provides better cleansing. It is clear now that both PEG and sodium phosphate are effective when administered with proper timing. Consequently, the timing of administration is recognized as one of the central factors to the quality of cleansing. The bowel preparation agent should be administered, at least in part, a few hours in advance of the colonoscopy. Several low volume agents are available, and either new or modified schedules with PEG that usually improve tolerance. Certain adjuvants can also be used to reduce the volume of PEG, or to improve the efficacy of other agents. Other factors apart from the choice of agent can improve the quality of bowel cleansing. For instance, the effect of diet before colonoscopy has not been completely clarified, but an exclusively liquid diet is probably not required, and a low-fiber diet may be preferable because it improves patient satisfaction and the quality of the procedure. Some patients, such as diabetics and persons with heart or kidney disease, require modified procedures and certain precautions. Bowel preparation for pediatric patients is also reviewed here. In such cases, PEG remains the most commonly used agent. As detecting neoplasia is not the main objective with these patients, less intensive preparation may suffice. Special considerations must be made for patients

  8. SAFETY OF MANNITOL USE IN BOWEL PREPARATION: a prospective assessment of intestinal methane (CH4) levels during colonoscopy after mannitol and sodium phosphate (NaP) bowel cleansing.

    PubMed

    Paulo, Gustavo Andrade de; Martins, Fernanda Prata Borges; Macedo, Erika Pereira de; Gonçalves, Manoel Ernesto Peçanha; Ferrari, Angelo Paulo

    2016-01-01

    - Adequate bowel preparation is critical for the quality of colonoscopy. Despite reported occurrence of colonic explosion due to methane and hydrogen production by bacterial fermentation during colonoscopy, gas exchange during the procedure is believed to be effective in lowering existing methane concentration, allowing for safe utilization of mannitol for bowel preparation. Thus, mannitol is widely used for bowel cleansing prior to colonoscopy, considering its low cost and effectiveness for bowel preparation. - The aim of this study was to assess the safety of mannitol for bowel preparation, when compared to sodium phosphate (NaP). - We conducted a prospective observational study in which 250 patients undergoing colonoscopy at Universidade Federal de São Paulo and Hospital Albert Einstein (São Paulo, Brazil) were approached for inclusion in the study. Patients received either mannitol (n=50) or NaP (n=200) for bowel preparation, based on physician indication. Study was conducted from August 2009 to December 2009. The main outcome of interest was presence of detectable levels of methane (CH4) during colonoscopy and reduction in such levels after gas exchange during the procedure. Methane concentrations were measured in three intestinal segments during scope introduction and withdrawal. Safety was assessed as the absence of high levels of methane, defined as 5%. Measurements were made using a multi-gas monitor (X-am 7000, Dräger Safety AG & Co. KGaA, Lübeck, Germany) connected to a plastic catheter introduced into the working channel of the colonoscope. Additional outcomes of interest included levels of O2. Methane and O2 levels are reported as ppm. Mean, difference and standard deviation of levels of gas measured in both moments were calculated and compared in both groups. Proportions of patients with detectable or high levels of methane in both groups were compared. Continuous variables were analyzed using t test and categorical variables using qui

  9. Combination could be another tool for bowel preparation?

    PubMed Central

    Soh, Jae Seung; Kim, Kyung-Jo

    2016-01-01

    Optimal bowel preparation increases the cecal intubation rate and detection of neoplastic lesions while decreasing the procedural time and procedural-related complications. Although high-volume polyethylene glycol (PEG) solution is the most frequently used preparation for bowel cleansing, patients are often unwilling to take PEG solution due to its large volume, poor palatability, and high incidence of adverse events, such as abdominal bloating and nausea. Other purgatives include osmotic agents (e.g., sodium phosphate, magnesium citrate, and sodium sulfate), stimulant agents (e.g., senna, bisacodyl, and sodium picosulfate), and prokinetic agents (e.g., cisapride, mosapride, and itopride). A combination of PEG with an osmotic, stimulant, or prokinetic agent could effectively reduce the PEG solution volume and increase patients’ adherence. Some such solutions have been found in several published studies to not be inferior to PEG alone in terms of bowel cleansing quality. Although combination methods showed similar efficacy and safety, the value of these studies is limited by shortcomings in study design. New effective and well-tolerated combination preparations are required, in addition to rigorous new validated studies. PMID:26973388

  10. Optimal preparation-to-colonoscopy interval in split-dose PEG bowel preparation determines satisfactory bowel preparation quality: an observational prospective study.

    PubMed

    Seo, Eun Hee; Kim, Tae Oh; Park, Min Jae; Joo, Hee Rin; Heo, Nae Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo

    2012-03-01

    Several factors influence bowel preparation quality. Recent studies have indicated that the time interval between bowel preparation and the start of colonoscopy is also important in determining bowel preparation quality. To evaluate the influence of the preparation-to-colonoscopy (PC) interval (the interval of time between the last polyethylene glycol dose ingestion and the start of the colonoscopy) on bowel preparation quality in the split-dose method for colonoscopy. Prospective observational study. University medical center. A total of 366 consecutive outpatients undergoing colonoscopy. Split-dose bowel preparation and colonoscopy. The quality of bowel preparation was assessed by using the Ottawa Bowel Preparation Scale according to the PC interval, and other factors that might influence bowel preparation quality were analyzed. Colonoscopies with a PC interval of 3 to 5 hours had the best bowel preparation quality score in the whole, right, mid, and rectosigmoid colon according to the Ottawa Bowel Preparation Scale. In multivariate analysis, the PC interval (odds ratio [OR] 1.85; 95% CI, 1.18-2.86), the amount of PEG ingested (OR 4.34; 95% CI, 1.08-16.66), and compliance with diet instructions (OR 2.22l 95% CI, 1.33-3.70) were significant contributors to satisfactory bowel preparation. Nonrandomized controlled, single-center trial. The optimal time interval between the last dose of the agent and the start of colonoscopy is one of the important factors to determine satisfactory bowel preparation quality in split-dose polyethylene glycol bowel preparation. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  11. Use of Powder PEG-3350 as a Sole Bowel Preparation

    PubMed Central

    Arora, Manish

    2008-01-01

    Objective: To assess the efficacy of low-volume powder polyethylene glycol (PEG)-3350 as a sole bowel preparation for colonoscopy. Methods: This case series examined 245 consecutive patients (a mixture of inpatients and outpatients undergoing screening colonoscopy) at a hospital endoscopy center over a 2-year period. The patients received powder PEG-3350 in the amount of 204 g dissolved in 32 oz of water and taken in 3 divided doses 1 hour apart with 8 oz of water in between each dose. Colon preparation scores (CPS) were used to assess the quality of colon cleansing. The results obtained from the 245 patients were collated and compared to those of patients receiving sodium phosphate, the historical control. Results: The mean CPS was calculated to be 3.43, with a standard deviation of 1.12. Of the 245 patients, 92 were scored with a grade of 4, and 5 patients had incomplete colonoscopies secondary to failure of bowel preparation (CPS=0). Among the remaining patients, 22 and 26 were graded as poor (CPS=1) or fair (CPS=2) bowel preparations, respectively. Conclusion: The low-volume powder PEG-3350 formula used in our case series showed effective colon cleansing and may be considered for use as a sole bowel preparation. PMID:21960925

  12. Picoprep-3 is a superior colonoscopy preparation to Fleet: a randomized, controlled trial comparing the two bowel preparations.

    PubMed

    Schmidt, Liu-Ming; Williams, Pamela; King, Denis; Perera, Dayashan

    2004-02-01

    Bowel preparations for colonoscopy have to balance the demand for adequate cleansing action of the bowel and patient acceptability. There has been no study comparing Picoprep-3 (sodium picosulfate), a relatively new product, to Fleet (sodium phosphate), a well-studied and widely used preparation. This study was designed to compare the efficacy and patient tolerance of these two bowel preparations for colonoscopy. A randomized, single-blinded, prospective trial was conducted. A total of 400 consecutive patients presenting for elective colonoscopy at St George Private Hospital during a 20-week period were randomly assigned to receive Picoprep-3 or Fleet. Patients were asked to record the effects of the preparation, noting tolerability, taste, and side effects. Two hundred patients were assigned to the Picoprep-3 group and 200 to the Fleet group. Surgeons were blinded to the preparation used and rated the quality of the bowel preparation on a scale of 1 to 5 (1 being the optimal score). Picoprep-3 was found to be better tolerated (P < 0.0001) and better tasting (P < 0.0001) than Fleet. Patients in the Picoprep-3 group reported significantly less nausea (P < 0.001), vomiting (P < 0.004), dizziness (P < 0.01), abdominal pains (P = 0.0005), and thirst (P < 0.0001) associated with the preparation. There was no significant difference in visualization of the colon between the two groups as judged by the two colonoscopists (P = 0.06). Colonoscopy preparation with Picoprep-3 has similar efficacy but superior taste and tolerability compared with Fleet. Picoprep-3 caused less adverse side effects in the study population.

  13. Bowel preparation for elective procedures in children: a systematic review and meta-analysis

    PubMed Central

    Karlsen, Fiona; Isaji, Sahira; Teck, Guan-Ong

    2017-01-01

    Objective Reviews have investigated preparation for colonoscopy, but not for surgery, They are also often limited to patients up to 16 years, despite many paediatric gastroenterologists caring for older patients. We carried out a systematic review investigating the optimum bowel preparation agents for all indications in children and young people. Design A Cochrane format systematic review of randomised controlled trials (RCTs). Data extraction and assessment of methodological quality were performed independently by two reviewers. Methodological quality was assessed using the Cochrane risk of bias tool. Patients Young people requiring bowel preparation for any elective procedure, as defined by the primary studies. Interventions RCTs comparing bowel preparation with placebo or other interventions. Main outcome measures Adequacy of bowel preparation, tolerability and adverse events. Results The search yielded 2124 results and 15 randomised controlled studies (n=1435)but heterogeneity limited synthesis. Meta-analysis of two studies comparing polyethylene glycol (PEG) with sodium phosphate showed no difference in the quality of bowel preparation (risk ratio (RR) 1.27(95% CI 0.66 to 2.44)). Two studies comparing sodium picosulfate/magnesium citrate with PEG found no difference in bowel preparation but significantly higher number of patients needing nasogastric tube insertion in the polyethylene glycol-electrolyte lavage solution (RR 0.04(95% CI 0.01 to 0.18), 45 of 117 in PEG group vs 2 of 121 in sodium picosulfate group). Meta-analysis of three studies (n=241) found no difference between PEG and sennasoids (RR 0.73(95% CI 0.31 to 1.71)). Conclusions The evidence base is clinically heterogeneous and methodologically at risk of bias. There is evidence that all regimens are equally effective. However, sodium picosulfate was better tolerated than PEG. Future research is needed with all agents and should seek to consider safety and tolerability as well as efficacy. PMID

  14. Systematic review and meta-analysis: Sodium picosulphate with magnesium citrate as bowel preparation for colonoscopy

    PubMed Central

    Munsterman, Isabelle D; Eskes, Anne M; Maaskant, Jolanda M; van der Hulst, René

    2016-01-01

    Background An effective and tolerable bowel preparation is important to secure quality of colonoscopies. It remains unclear if sodium picosulphate with magnesium citrate (SPMC), which is considered a tolerable bowel preparation agent, is also an effective alternative for polyethylene glycol (PEG) and sodium phosphate (NaP). Aim The aim of this article is to compare effectiveness of SPMC to PEG and NaP through assessment of quality of bowel cleansing measured by validated tools. Methods We searched electronic databases up to January 2015. Only randomised controlled trials (RCTs) were included. Two authors independently performed selection of studies, risk of bias assessment and data extraction. Results Thirteen RCTs were included, with overall good quality, but large heterogeneity. SPMC had slightly better quality of bowel cleansing than PEG (pooled RR 1.06; 95% CI 1.02 to 1.11). In most trials SPMC was significantly better tolerated than PEG. There were no significant differences in effectiveness or tolerability between SPMC and NaP. Side effects were similar between agents, except for dizziness (pooled RR 1.71; 95% CI 1.32 to 2.21 in favour of PEG vs. SPMC) and vomiting (pooled RR 0.35; 95% CI 0.13 to 0.95 in favour of single-dose SPMC vs. split-dose). Conclusions SPMC is equally effective to NaP and little superior to PEG in terms of bowel cleansing. SPMC preparations were better tolerated than PEG preparations. SPMC may be considered as standard bowel preparation for colonoscopy. PMID:29163958

  15. Comparative study of two bowel preparaton regimens for colonoscopy: Senna tablets vs sodium phosphate solution

    PubMed Central

    Kositchaiwat, Savit; Suwanthanmma, Weerapat; Suvikapakornkul, Ronnarat; Tiewthanom, Vaewvadee; Rerkpatanakit, Prisna; Tinkornrusmee, Chaowalitr

    2006-01-01

    AIM: To compare the efficacy and acceptance of senna tablet and sodium phosphate solution for bowel preparation before colonoscopy. METHODS: One hundred and thirty four patients, who needed elective colonoscopy, were randomly allocated to take 180 mg senna tablet or 95 mL sodium phosphate solution on the day before colonoscopy. The efficacies of both laxatives were compared using the mean difference of colon-cleanliness score of the rectum, sigmoid segments, descending colon, transverse colon and cecum. The scores were rated by two observers who were blinded to the laxatives administered. The higher score means that the colon is cleaner. The efficacy of both laxatives were equivalent if the 95% confidence interval of the mean difference of the score of colon lie within -1 to +1. RESULTS: On intention-to-treat analysis, the mean cleanliness scores in the four segments of colon except the cecum were higher in the sodium phosphate group than those in senna group (7.9 ± 1.7 vs 8.3 ± 1.5, 8.0 ± 1.8 vs 8.5 ± 1.4, 7.9 ± 2.0 vs 8.5 ± 1.3, 7.9 ± 2.0 vs 8.2 ± 1.4 and 7.2 ± 1.7 vs 6.9 ± 1.4, respectively). The 95% confidence intervals (95% CI) of mean difference in each segment of colon were not found to lie within 1 point which indicated that their efficacies were not equivalent. The taste of senna was better than sodium phosphate solution. Also, senna had fewer side effects. CONCLUSION: The efficacy of senna is not equivalent to sodium phosphate solution in bowel preparation for colonoscopy, but senna may be considered an alternative laxative. PMID:17006995

  16. Guidelines for Bowel Preparation before Video Capsule Endoscopy

    PubMed Central

    Song, Hyun Joo; Do, Jae Hyuk; Cha, In Hye; Yang, Chang Hun; Choi, Myung-Gyu; Jeen, Yoon Tae; Kim, Hyun Jung

    2013-01-01

    The preparation for video capsule endoscopy (VCE) of the bowel suggested by manufacturers of capsule endoscopy systems consists only of a clear liquid diet and an 8-hour fast. While there is evidence for a benefit from bowel preparation for VCE, so far there is no domestic consensus on the preparation regimen in Korea. Therefore, we performed this study to recommend guidelines for bowel preparation before VCE. The guidelines on VCE were developed by the Korean Gut Image Study Group, part of the Korean Society of Gastrointestinal Endoscopy. Four key questions were selected. According to our guidelines, bowel preparation with polyethylene glycol (PEG) solution enhances small bowel visualization quality (SBVQ) and diagnostic yield (DY), but it has no effect on cecal completion rate (CR). Bowel preparation with 2 L of PEG solution is similar to that with 4 L of PEG in terms of the SBVQ, DY, and CR of VCE. Bowel preparation with fasting or PEG solution combined with simethicone enhances the SBVQ, but it does not affect the CR of VCE. Bowel preparation with prokinetics does not enhance the SBVQ, DY, or CR of VCE. PMID:23614124

  17. Use of Powder PEG-3350 as a Sole Bowel Preparation: Clinical Case Series of 245 Patients.

    PubMed

    Arora, Manish; Okolo, Patrick I

    2008-07-01

    To assess the efficacy of low-volume powder polyethylene glycol (PEG)-3350 as a sole bowel preparation for colonoscopy. This case series examined 245 consecutive patients (a mixture of inpatients and outpatients undergoing screening colonoscopy) at a hospital endoscopy center over a 2-year period. The patients received powder PEG-3350 in the amount of 204 g dissolved in 32 oz of water and taken in 3 divided doses 1 hour apart with 8 oz of water in between each dose. Colon preparation scores (CPS) were used to assess the quality of colon cleansing. The results obtained from the 245 patients were collated and compared to those of patients receiving sodium phosphate, the historical control. The mean CPS was calculated to be 3.43, with a standard deviation of 1.12. Of the 245 patients, 92 were scored with a grade of 4, and 5 patients had incomplete colonoscopies secondary to failure of bowel preparation (CPS=0). Among the remaining patients, 22 and 26 were graded as poor (CPS=1) or fair (CPS=2) bowel preparations, respectively. The low-volume powder PEG-3350 formula used in our case series showed effective colon cleansing and may be considered for use as a sole bowel preparation.

  18. Mechanical bowel preparation in colorectal surgery.

    PubMed

    Kolovrat, Marijan; Busić, Zeljko; Lovrić, Zvonimir; Amić, Fedor; Cavka, Vlatka; Boras, Zdenko; Servis, Drazen; Lemac, Domagoj; Busić, Njegoslav

    2012-12-01

    The aim of this study was to assess the use of mechanical bowel preparation (MBP) and antimicrobial prophylaxis in elective colorectal surgery regarding still existing controversies. A prospective study of 85 patients undergoing elective colon and rectal surgery during 2 years period was performed, divided in two groups. Group A (N = 46) with patients who underwent mechanical bowel preparation, and group B (N = 39) patients without mechanical bowel preparation. We analysed: gender, age, preoperative difficulties, diagnostic colonoscopy, tumor localization, operation performed, pathohystological findings, Dukes classification, number of lymphonodes inspected, liver metastasis, other organ infiltrations, mean time of surgery, length of hospital stay, postoperative complications and mortality. Demographic characteristics, pathohystological findings, the site of malignancy, and type of surgical procedure did not significantly differentiate the two groups. The only significance revealed in mean time of surgery (138/178 minutes) in favor of patients with MBP (p = 0.017). Mechanical bowel preparation (MBP) for elective colorectal surgery is not advantageous. It does not influence radicalism of the procedure, does not decrease neither postoperative complications, nor hospital mortality.

  19. Bowel preparation for colonoscopy: state of the art.

    PubMed

    Voiosu, Theodor; Voiosu, Andrei; Voiosu, Radu

    2016-07-13

    Bowel preparation for colonoscopy is a key quality indicator that impacts on all aspects of the procedure, such as patient comfort, diagnostic yield, and adverse events. Although most laxative regimens currently employed have been compared in a multitude of settings, the optimal preparation regimen still remains an open question. Recent studies have focused on developing new regimens by modifying dosage, timing of administration or by combining laxatives with synergic mechanisms of action with the purpose of increasing patient tolerability while maximizing bowel cleansing. Several low-volume preparations and combinations of laxatives and adjunctive medication have shown promise in delivering both adequate preparation of the colon and good patient tolerability. Also, we have gained a better understanding of the influence of patient-related factors such as health literacy and education on the quality of bowel preparation. Although several novel regimens have been tested in recent trials, it remains unclear which, if any, of these bowel preparations can replace the standard bowel cleansing regimens in clinical practice. Also, further data are required on how to improve bowel cleansing by choosing the appropriate regimen for the individual patient.

  20. Comparison of the Efficacy and Safety of Sodium Phosphate Tablets and Polyethylene Glycol Solution for Bowel Cleansing in Healthy Korean Adults

    PubMed Central

    Lee, Seung-Hwa; Kim, Kwang-Min; Seo, Sang-Wook; Kang, Joon-Koo; Lee, Eun-Hye; Lee, Dong-Ryul

    2014-01-01

    Purpose Bowel cleansing is generally regarded as time-consuming and unpleasant among patients. Patients commonly state that bowel preparation provokes more discomfort than the actual colonoscopic examination. The purpose of this study was to compare two regimens of sodium phosphate (NaP) tablets versus polyethylene glycol (PEG) solution for bowel preparation in healthy Korean adults. Materials and Methods This was a single center, prospective, open-label, investigator-blinded, randomized, controlled-pilot study. A total of 62 healthy Korean subjects were randomly assigned to two groups (NaP vs. PEG). Efficacy, safety, and patient-related outcomes, as well as procedural parameters, were evaluated. Results Although there were no significant differences in total Ottawa bowel quality score, fluid scores and the rate of adequate bowel preparation were significantly better in the NaP group than the PEG group. Additionally, the NaP group showed better results regarding patient tolerance, satisfaction, preference, and rate of adverse events than the PEG group. Significant fluctuations in specific serum electrolytes were common and of a greater magnitude in the NaP group than the PEG group. However, these abnormalities were transient and did not result in serious complications and side effects. Conclusion In this study, NaP tablets were shown to be an effective, well-tolerated, and acceptable regimen for bowel preparation. Also, our study suggests that NaP tablets may be safe and can be used as a bowel cleansing agent in healthy adults undergoing elective colonoscopy. Further multicenter, large scale studies are needed to confirm these findings. PMID:25323890

  1. Optimizing bowel preparation for colonoscopy: a guide to enhance quality of visualization

    PubMed Central

    Bechtold, Matthew L.; Mir, Fazia; Puli, Srinivas R.; Nguyen, Douglas L.

    2016-01-01

    Colonoscopy is an important screening and therapeutic modality for colorectal cancer. Unlike other screening tests, colonoscopy is dependent on pre-procedure bowel preparation. If the bowel preparation is poor, significant pathology may be missed. Many factors are known to improve bowel preparation. This review will highlight those factors that may optimize the bowel preparation, including choice of bowel preparation, grading or scoring of the bowel preparation, special factors that influence preparation, and diet prior to colonoscopy that affects bowel preparation. The aim of the review is to offer suggestions and guide endoscopists on how to optimize the bowel preparation for the patients undergoing colonoscopy. PMID:27065725

  2. Bowel preparations for colonoscopy: an RCT.

    PubMed

    Di Nardo, Giovanni; Aloi, Marina; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Civitelli, Fortunata; Nuti, Federica; Ziparo, Chiara; Pession, Andrea; Lima, Mario; La Torre, Giuseppe; Oliva, Salvatore

    2014-08-01

    The ideal preparation regimen for pediatric colonoscopy remains elusive, and available preparations continue to represent a challenge for children. The aim of this study was to compare the efficacy, safety, tolerability, and acceptance of 4 methods of bowel cleansing before colonoscopy in children. This randomized, investigator-blinded, noninferiority trial enrolled all children aged 2 to 18 years undergoing elective colonoscopy in a referral center for pediatric gastroenterology. Patients were randomly assigned to receive polyethylene glycol (PEG) 4000 with simethicon (PEG-ELS group) or PEG-4000 with citrates and simethicone plus bisacodyl (PEG-CS+Bisacodyl group), or PEG 3350 with ascorbic acid (PEG-Asc group), or sodium picosulfate plus magnesium oxide and citric acid (NaPico+MgCit group). Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale. The primary end point was overall colon cleansing. Tolerability, acceptability, and compliance were also evaluated. Two hundred ninety-nine patients were randomly allocated to the 4 groups. In the per-protocol analysis, PEG-CS+Bisacodyl, PEG-Asc, and NaPico+MgCit were noninferior to PEG-ELS in bowel-cleansing efficacy of both the whole colon (P = .910) and colonic segments. No serious adverse events occurred in any group. Rates of tolerability, acceptability, and compliance were significantly higher in the NaPico+MgCit group. Low-volume PEG preparations (PEG-CS+Bisacodyl, PEG-Asc) and NaPico+MgCit are noninferior to PEG-ELS in children, representing an attractive alternative to high-volume regimens in clinical practice. Because of the higher tolerability and acceptability profile, NaPico+MgCit would appear as the most suitable regimen for bowel preparation in children. Copyright © 2014 by the American Academy of Pediatrics.

  3. Importance of the Time Interval between Bowel Preparation and Colonoscopy in Determining the Quality of Bowel Preparation for Full-Dose Polyethylene Glycol Preparation

    PubMed Central

    Kim, Tae Kyung; Kim, Hyung Wook; Kim, Su Jin; Ha, Jong Kun; Jang, Hyung Ha; Hong, Young Mi; Park, Su Bum; Choi, Cheol Woong; Kang, Dae Hwan

    2014-01-01

    Background/Aims The quality of bowel preparation (QBP) is the important factor in performing a successful colonoscopy. Several factors influencing QBP have been reported; however, some factors, such as the optimal preparation-to-colonoscopy time interval, remain controversial. This study aimed to determine the factors influencing QBP and the optimal time interval for full-dose polyethylene glycol (PEG) preparation. Methods A total of 165 patients who underwent colonoscopy from June 2012 to August 2012 were prospectively evaluated. The QBP was assessed using the Ottawa Bowel Preparation Scale (Ottawa) score according to several factors influencing the QBP were analyzed. Results Colonoscopies with a time interval of 5 to 6 hours had the best Ottawa score in all parts of the colon. Patients with time intervals of 6 hours or less had the better QBP than those with time intervals of more than 6 hours (p=0.046). In the multivariate analysis, the time interval (odds ratio, 1.897; 95% confidence interval, 1.006 to 3.577; p=0.048) was the only significant contributor to a satisfactory bowel preparation. Conclusions The optimal time was 5 to 6 hours for the full-dose PEG method, and the time interval was the only significant contributor to a satisfactory bowel preparation. PMID:25368750

  4. Efficiency of bowel preparation for capsule endoscopy examination: a meta-analysis.

    PubMed

    Niv, Yaron

    2008-03-07

    Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as "good" in 78% of the examinations performed with preparation and 49% performed without (P<0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum.

  5. Efficiency of bowel preparation for capsule endoscopy examination: A meta-analysis

    PubMed Central

    Niv, Yaron

    2008-01-01

    Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as “good” in 78% of the examinations performed with preparation and 49% performed without (P < 0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum. PMID:18322940

  6. Should bowel preparation, antifoaming agents, or prokinetics be used before video capsule endoscopy? A systematic review and meta-analysis.

    PubMed

    Kotwal, Vikram S; Attar, Bashar M; Gupta, Saurabh; Agarwal, Rajender

    2014-02-01

    The ideal bowel preparation regime before small bowel video capsule endoscopy (VCE) is not known. We carried out a systematic review and meta-analysis to study the effect of purgatives, antifoaming agents, and prokinetics on the outcomes associated with VCE. We performed literature searches in MEDLINE and Cochrane Library and included randomized-controlled trials studying the effect of purgatives, antifoaming agents, and prokinetics in patients undergoing VCE. Our outcomes of interest were visualization quality, diagnostic yield, and completion rate. Meta-analyses were carried out using the RevMan software and heterogeneity was assessed using the I statistic. Fifteen studies fulfilled the inclusion criteria. As compared with no bowel preparation, bowel preparation with polyethylene glycol (PEG) led to adequate visualization in a significantly higher number of patients undergoing VCE [odds ratio (OR) 3.13; 95% confidence interval (CI) 1.70-5.75]. Both PEG and sodium phosphate significantly improved the diagnostic yield (OR 1.68; 95% CI 1.16-2.42 and OR 1.77; 95% CI 1.18-2.64, respectively) but did not affect the completion rate. All studies with simethicone showed significantly improved visualization quality with its use as compared with overnight fasting or purgatives alone. Prokinetics did not significantly improve the completion rate of VCE. On the basis of the data available, a combination of PEG and simethicone appears to be the best approach for small bowel preparation before VCE. However, large multicenter randomized-controlled trials are needed to validate this recommendation and to evaluate the ideal dose of PEG and timing of bowel preparation before VCE. Prokinetics administered before VCE do not improve the completion rate and should not be used.

  7. Impact of mechanical bowel preparation in elective colorectal surgery: A meta-analysis.

    PubMed

    Rollins, Katie E; Javanmard-Emamghissi, Hannah; Lobo, Dileep N

    2018-01-28

    To analyse the effect of mechanical bowel preparation vs no mechanical bowel preparation on outcome in patients undergoing elective colorectal surgery. Meta-analysis of randomised controlled trials and observational studies comparing adult patients receiving mechanical bowel preparation with those receiving no mechanical bowel preparation, subdivided into those receiving a single rectal enema and those who received no preparation at all prior to elective colorectal surgery. A total of 36 studies (23 randomised controlled trials and 13 observational studies) including 21568 patients undergoing elective colorectal surgery were included. When all studies were considered, mechanical bowel preparation was not associated with any significant difference in anastomotic leak rates (OR = 0.90, 95%CI: 0.74 to 1.10, P = 0.32), surgical site infection (OR = 0.99, 95%CI: 0.80 to 1.24, P = 0.96), intra-abdominal collection (OR = 0.86, 95%CI: 0.63 to 1.17, P = 0.34), mortality (OR = 0.85, 95%CI: 0.57 to 1.27, P = 0.43), reoperation (OR = 0.91, 95%CI: 0.75 to 1.12, P = 0.38) or hospital length of stay (overall mean difference 0.11 d, 95%CI: -0.51 to 0.73, P = 0.72), when compared with no mechanical bowel preparation, nor when evidence from just randomized controlled trials was analysed. A sub-analysis of mechanical bowel preparation vs absolutely no preparation or a single rectal enema similarly revealed no differences in clinical outcome measures. In the most comprehensive meta-analysis of mechanical bowel preparation in elective colorectal surgery to date, this study has suggested that the use of mechanical bowel preparation does not affect the incidence of postoperative complications when compared with no preparation. Hence, mechanical bowel preparation should not be administered routinely prior to elective colorectal surgery.

  8. Bowel preparation for colonoscopy with magnesium sulphate and low-volume polyethylene glycol.

    PubMed

    Tepeš, Bojan; Mlakar, Dominika N; Metličar, Tanja

    2014-06-01

    Patient compliance with bowel cleansing procedures represents one of the most objectionable aspects of colonoscopy. Adverse reactions to the purgative may result in failure to complete the preparation, inadequate visualization of the colon, polyp and even carcinoma miss rate and unwillingness to attend a follow-up colonoscopy. The primary objective of the study was to evaluate the effectiveness of bowel cleansing with magnesium sulphate and low-volume polyethylene glycol (PEG) with electrolytes. The second objective was to evaluate whether bowel cleansing was better in participants scheduled for morning colonoscopies or afternoon colonoscopies. Magnesium sulphate mineral water (2 l) and 2 l of low-volume PEG and electrolytes solution were used as our bowel cleansing protocol. A total of 13 914 participants, who participated in the Slovenian colorectal cancer screening programme in the period between 2009 and 2011, were included. Excellent bowel preparation was achieved in 11 484 (82.61%) participants; 1894 (13.62%) participants had good bowel preparation, 439 (3.16%) participants had fair bowel preparation and 85 (0.61%) participants had poor bowel preparation. Better results were achieved in the afternoon colonoscopies and in younger participant groups (P<0.001). No serious side effects of bowel cleansing were reported. This is the first study to use magnesium sulphate mineral water and PEG plus electrolytes for bowel cleansing. We found excellent bowel cleansing in 82.61% participants and in more participants if colonoscopy was performed in the afternoon.

  9. Effect of small bowel preparation with simethicone on capsule endoscopy.

    PubMed

    Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling

    2009-01-01

    Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed.

  10. Effect of small bowel preparation with simethicone on capsule endoscopy*

    PubMed Central

    Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling

    2009-01-01

    Background: Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Methods: Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Results: Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Conclusion: Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed. PMID:19198022

  11. [Effects of a Patient Educational Video Program on Bowel Preparation Prior to Colonoscopy].

    PubMed

    Cho, You Young; Kim, Hyeon Ok

    2015-10-01

    The purpose of this study was to evaluate the effects of an educational video program on bowel preparation for a colonoscopy. The study used a non-equivalent control group and non-synchronized design as a quasi-experimental research involving 101 participants undergoing bowel preparation for a colonoscopy (experimental group 51, control group 50 subjects) at W. university hospital, from Aug. 7 to Oct. 31, 2013. The control group received verbal education with an explanatory note while the experimental group received education using a video program. To measure knowledge of diet restrictions and compliance with ingesting bowel preparation solutions, a questionnaire, based on The Korean Society of Gastrointestinal Endoscopy's Guide (2003), developed by Sam-Sook You, was used after revisions and supplementation was done. To measure bowel cleanness, the 'Aronchick Bowel Preparation Scale' was adopted. Data were analyzed using the SPSS WIN 12.0 program. A higher proportion of the experimental group showed a positive change in knowledge level on diet restrictions (U=1011.50, p=.035) and ingestion of bowel preparation solutions (U=980.50, p=.019), a higher level of compliance with diet restrictions (U=638.50, p<.001), ingesting bowel preparation solutions (U=668.00, p<.001) and the level of bowel cleanness (χ²=17.00, p<.001) than the control group. The results of this study indicate that a video educational program for patients having a colonoscopy can improve knowledge, level of compliance with diet restrictions, ingestion of bowel preparation solutions, and bowel cleanness. Therefore video educational program should be used with this patient group.

  12. Patients with History of Colonoscopy Are Less Likely to Achieve High Quality Preparation After Implementing Split-Dose Bowel Preparation.

    PubMed

    Madhoun, M F; Bitar, H; Parava, P; Bashir, M H; Zia, H

    2017-01-01

    Anecdotally, we observed that patients who had previous colonoscopies were less likely to follow newly implemented split-dose bowel preparation (SDBP) instructions. We investigated whether the indication for colonoscopy is an independent factor for achieving high quality bowel preparation among patients asked to follow SDBP. We performed a retrospective study of data from 1478 patients who received outpatient colonoscopies in 2014 (the year of SDBP implementation) at our Veterans Affairs Medical Center. We collected information related to demographics and factors known to affect bowel preparations. Reasons for colonoscopy were dichotomized into surveillance (previous colonoscopy) vs. non-surveillance (positive occult blood test or screening). Bowel preparation quality was scored using the Boston Bowel Preparation Scale (BBPS), and was categorized as either excellent vs. not excellent (BBPS≥7 vs. BBPS<7), or adequate vs. inadequate (BBPS≥6 vs. BBPS<6). Bowel preparation quality was excellent in 60% of colonoscopies and adequate in 84% of colonoscopies. Thirty-six percent (535) were surveillance colonoscopies. In multivariate logistic regression analysis, more patients in the non-surveillance group achieved excellent (OR 0.8 ; 95% CI [0.7-0.8], P <0.0001) and adequate (OR 0.8 ; 95% CI [0.7-0.9], P <0.006) bowel preparation than did patients in the surveillance group. Patients with a prior colonoscopy might not follow the split-dose bowel preparation instructions. Educational interventions emphasizing the benefits of SDBP in this group of patients may help ensure compliance and prevent the habitual use of day-before preparations. © Acta Gastro-Enterologica Belgica.

  13. Providing Hospitalized Patients With an Educational Booklet Increases the Quality of Colonoscopy Bowel Preparation.

    PubMed

    Ergen, William F; Pasricha, Trisha; Hubbard, Francie J; Higginbotham, Tina; Givens, Tonya; Slaughter, James C; Obstein, Keith L

    2016-06-01

    Inadequate bowel preparation is a problem frequently encountered by gastroenterologists who perform colonoscopies on hospitalized patients. A method is needed to increase the quality of bowel preparation in inpatients. An educational booklet has been shown to increase the overall quality of bowel preparation for outpatients. We performed a prospective study to evaluate the effects of an educational booklet on the quality of bowel preparation in a group of hospitalized patients. We performed a randomized, single-blind, controlled trial of all inpatients at a tertiary care medical center scheduled for inpatient colonoscopy from October 2013 through March 2014. They were randomly assigned to groups that were (n = 45) or were not (controls, n = 40) given the booklet before bowel preparation the evening before their colonoscopy. All patients received a standard bowel preparation (clear liquid diet the day before the procedure, followed by split-dose GoLYTELY). At the colonoscopy, the Boston Bowel preparation scale (BBPS) was used to assess bowel preparation. The primary outcome measure was adequate bowel preparation (a total BBPS score ≥6 with all segment scores ≥2). Secondary outcomes assessed included total BBPS score, BBPS segment score, and a total BBPS score of 0. There were no differences between the groups in age, race, sex, body mass index, history of colonoscopy, history of polyps, or time of colonoscopy. Twenty-eight patients who received the booklet (62%) and 14 who did not (35%) had an adequate bowel preparation (P = .012). The number needed to treat to attain adequate bowel preparation was 4. After adjusting for age and history of prior colonoscopies, the odds of achieving an adequate bowel preparation and a higher total BBPS score after receipt of the booklet were 3.14 (95% confidence interval, 1.29-7.83) and 2.27 (95% confidence interval, 1.05-4.88), respectively. Three patients in the booklet group and 9 in the no-booklet group had a BBPS score

  14. Extreme hyperphosphatemia and hypocalcemic coma associated with phosphate enema.

    PubMed

    Hsu, Heng Jung; Wu, Mai-Szu

    2008-01-01

    Fleet enema (sodium phosphate, C.B. Fleet Co., Inc., Lynchburg, Virginia) is widely used for bowel preparation or constipation relief in the hospital and over the counter. The potential risks, including hyperphosphatemia and hypocalcemic coma should be kept in mind of primary care physician. The patients with older age, bowel obstruction, small intestinal disorders, poor gut motility, and renal disease are contraindicated or should be administered with caution. We present a patient with old age and chronic renal failure who developed severe hyperphosphatemia and hypocalcemic tetany with coma after sodium phosphate enema. We recommend the use of alternative enema preparations, such as simple tap water or saline solution enemas, which can prevent fatal complications in high risk patients.

  15. Gastric emptying evaluation by ultrasound prior colonoscopy: An easy tool following bowel preparation

    PubMed Central

    Coriat, Romain; Polin, Vanessa; Oudjit, Ammar; Henri, Franck; Dhooge, Marion; Leblanc, Sarah; Delchambre, Chantal; Esch, Anouk; Tabouret, Tessa; Barret, Maximilien; Prat, Frédéric; Chaussade, Stanislas

    2014-01-01

    AIM: To investigate the gastric emptying after bowel preparation to allow general anaesthesia. METHODS: A prospective, non-comparative, and non-randomized trial was performed and registered on Eudra CT database (2011-002953-80) and on www.trial.gov (NCT01398098). All patients had a validated indication for colonoscopy and a preparation using sodium phosphate (NaP) tablets. The day of the procedure, patients took 4 tablets with 250 mL of water every 15 min, three times. The gastric volume was estimated every 15 min from computed antral surfaces and weight according to the formula of Perlas et al (Anesthesiology, 2009). Colonoscopy was performed within the 6 h following the last intake. RESULTS: Thirty patients were prospectively included in the study from November 2011 to May 2012. The maximum volume of the antrum was 212 mL, achieved 15 min after the last intake. 24%, 67% and 92% of subjects had an antral volume below 20 mL at 60, 120 and 150 min, respectively. 81% of patients had a Boston score equal to 2 or 3 in each colonic segment. No adverse events leading to treatment discontinuation were reported. CONCLUSION: Gastric volume evaluation appeared to be a simple and reliable method for the assessment of gastric emptying. Data allow considering the NaP tablets bowel preparation in the morning of the procedure and confirming that gastric emptying is achieved after two hours, allowing general anaesthesia. PMID:25309090

  16. Efficacy of prokinetic agents in improving bowel preparation for colonoscopy.

    PubMed

    Mishima, Yuko; Amano, Yuji; Okita, Koichi; Takahashi, Yoshiko; Moriyama, Nobuyuki; Ishimura, Norihisa; Furuta, Kenji; Ishihara, Shunji; Adachi, Kyoichi; Kinoshita, Yoshikazu

    2008-01-01

    Colonoscopy plays an important role in the diagnosis and treatment of gastrointestinal illness in both Western countries and Japan. However, preparative bowel cleansing for colonoscopy is frequently troublesome for elderly and/or constipated patients, since they must drink larger volumes of lavage solution for adequate cleansing. We investigated the use of prokinetic agents for improving the efficacy and tolerability of bowel cleansing prior to colonoscopy. 613 patients were divided into two groups according to oral lavage solution used (polyethylene glycol or magnesium citrate), and were further randomized to receive either vehicle (100 ml water) alone, vehicle with 5 mg mosapride citrate, or vehicle with 50 mg itopride hydrochloride 30 min before administration of lavage solution. Experimental parameters included bowel cleansing quality, times to first defecation and completion of bowel cleansing, and incidence of uncomfortable abdominal symptoms during colonoscopy preparation. Administration of mosapride citrate or itopride hydrochloride prior to oral lavage solution did not significantly improve bowel cleansing quality. However, statistically significantly fewer uncomfortable abdominal symptoms were found in patients who received mosapride citrate or itopride hydrochloride versus vehicle alone. Prokinetic agents effectively decreased the incidence of uncomfortable abdominal symptoms experienced during colonoscopy preparation. Copyright 2008 S. Karger AG, Basel.

  17. YouTube™ as a Source of Instructional Videos on Bowel Preparation: a Content Analysis.

    PubMed

    Ajumobi, Adewale B; Malakouti, Mazyar; Bullen, Alexander; Ahaneku, Hycienth; Lunsford, Tisha N

    2016-12-01

    Instructional videos on bowel preparation have been shown to improve bowel preparation scores during colonoscopy. YouTube™ is one of the most frequently visited website on the internet and contains videos on bowel preparation. In an era where patients are increasingly turning to social media for guidance on their health, the content of these videos merits further investigation. We assessed the content of bowel preparation videos available on YouTube™ to determine the proportion of YouTube™ videos on bowel preparation that are high-content videos and the characteristics of these videos. YouTube™ videos were assessed for the following content: (1) definition of bowel preparation, (2) importance of bowel preparation, (3) instructions on home medications, (4) name of bowel cleansing agent (BCA), (5) instructions on when to start taking BCA, (6) instructions on volume and frequency of BCA intake, (7) diet instructions, (8) instructions on fluid intake, (9) adverse events associated with BCA, and (10) rectal effluent. Each content parameter was given 1 point for a total of 10 points. Videos with ≥5 points were considered by our group to be high-content videos. Videos with ≤4 points were considered low-content videos. Forty-nine (59 %) videos were low-content videos while 34 (41 %) were high-content videos. There was no association between number of views, number of comments, thumbs up, thumbs down or engagement score, and videos deemed high-content. Multiple regression analysis revealed bowel preparation videos on YouTube™ with length >4 minutes and non-patient authorship to be associated with high-content videos.

  18. Coffee Enema for Preparation for Small Bowel Video Capsule Endoscopy: A Pilot Study

    PubMed Central

    Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang

    2014-01-01

    Coffee enemas are believed to cause dilatation of bile ducts and excretion of bile through the colon wall. Proponents of coffee enemas claim that the cafestol palmitate in coffee enhances the activity of glutathione S-transferase, an enzyme that stimulates bile excretion. During video capsule endoscopy (VCE), excreted bile is one of the causes of poor preparation of the small bowel. This study aimed to evaluate the feasibility and effect of coffee enema for preparation of the small bowel during VCE. In this pilot study, 17 of 34 patients were assigned to the coffee enema plus polyethylene glycol (PEG) 2 L ingestion group, whereas the 17 remaining control patients received 2 L of PEG only. The quality of bowel preparation was evaluated in the two patient groups. Bowel preparations in the proximal segments of small bowel were not differ between two groups. In the mid and distal segments of the small intestine, bowel preparations tend to be better in patients who received coffee enemas plus PEG than in patients who received PEG only. The coffee enema group did not experience any complications or side effects. Coffee enemas may be a feasible option, and there were no clinically significant adverse events related to coffee enemas. More prospective randomized studies are warranted to improve small bowel preparation for VCE. PMID:25136541

  19. Prospective analysis of factors associated with inadequate bowel preparation for colonoscopy in actual clinical practice

    PubMed Central

    Woo, Dae Hyung; Jeong, Da Eun; Nam, Yoon Jeong; Lee, Si Hyung; Jang, Byung Ik; Kim, Tae Nyeun

    2018-01-01

    Background/Aims Inadequate bowel preparation can result in prolonged procedure time and increased missed lesion and complication rates. This prospective study aimed to evaluate bowel preparation quality and identify the predictive factors for inadequate bowel preparation in actual clinical practice. Methods We included 399 patients who underwent colonoscopy between June 2015 and July 2016. Using the Aronchick bowel preparation scale, we defined a score ≤2 as adequate preparation and a score >2 as inadequate preparation. Results Mean patient age was 58.38±12.97 years; 60.6% were male. Indications for colonoscopy included screening (69.7%) and surveillance after polyp removal (21.3%). A split-dose regimen was prescribed to 55.4% of patients. The inadequate bowel preparation rate was 28.1%. Overall, the median time between the last bowel preparation agent dose and start of colonoscopy was 5.0 hours (range, 1.5–16.0 hours); that of the adequate group was 5.0 hours (range, 1.5–16.0 hours); and that of the inadequate group was 5 hours (range, 2–23 hours). The mean bowel preparation scale score of the ascending colon (1.94±0.25) was significantly higher than that of other colon segments. On multivariate analysis, elderly age, history of cerebrovascular disease, history of gastrectomy or appendectomy, and total preparation solution uptake <2 L were the independent predictors of inadequate bowel preparation. Conclusions The inadequate bowel preparation rate was 28.1%. Risk factors included elderly age and history of cerebrovascular disease or abdominal surgery. Patients with these risk factors require special care and education. PMID:29743843

  20. Do adjuvants add to the efficacy and tolerance of bowel preparations? A meta-analysis of randomized trials.

    PubMed

    Restellini, Sophie; Kherad, Omar; Menard, Charles; Martel, Myriam; Barkun, Alan N

    2018-02-01

    BACKGROUND AND STUDY AIMS : Recommendations on adjuvant use with bowel preparations remain disparate. We performed a meta-analysis determining the clinical impact of adding an adjuvant to polyethylene glycol (PEG), sodium phosphate, picosulfate (PICO), or oral sulfate solutions (OSS)-based regimens.  Systematic searches were made of MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials from January 1980 to April 2016 that assessed preparations with or without adjuvants, given in split and non-split dosing, and PEG high- (> 3 L) or low-dose (≤ 2 L) regimens. Bowel cleansing efficacy was the primary outcome. Secondary outcomes included patient willingness to repeat the procedure, and polyp and adenoma detection rates.  Of 3093 citations, 77 trials fulfilled the inclusion criteria. Overall, addition of an adjuvant compared with no adjuvant, irrespective of the type of preparation and mode of administration, yielded improvements in bowel cleanliness (odds ratio [OR] 1.23 [1.01 - 1.51]) without greater willingness to repeat (OR 1.40 [0.91 - 2.15]). Adjuvants combined with high-dose PEG significantly improved colon cleansing (OR 1.96 [1.32 - 2.94]). The odds for achieving adequate preparation with low-dose PEG with an adjuvant were not different to high-dose PEG alone (OR 0.95 [0.73 - 1.22]), but yielded improved tolerance (OR 3.22 [1.85 - 5.55]). However, split high-dose PEG yielded superior cleanliness to low-dose PEG with adjuvants (OR 2.53 [1.25 - 5.13]). No differences were noted for OSS and PICO comparisons, or for any products regarding polyp or adenoma detection rates.  Critical heterogeneity precludes firm conclusion on the impact of adjuvants with existing bowel preparations. Additional research is required to better characterize the methods of administration and resulting roles of adjuvants in an era of split-dosing. © Georg Thieme Verlag KG Stuttgart · New York.

  1. One-day bowel preparation with polyethylene glycol 3350: an effective regimen for colonoscopy in children.

    PubMed

    Adamiak, Tonya; Altaf, Muhammad; Jensen, Michael K; Sultan, Mutaz; Ramprasad, Jonathan; Ciecierega, Thomas; Sherry, Karen; Miranda, Adrian

    2010-03-01

    Polyethylene glycol (PEG) 3350 is commonly used and has been proven safe and effective for the treatment of chronic constipation and as a 4-day bowel preparation in children. A 1-day PEG 3350 bowel preparation regimen has been recently developed for adults; however, data regarding its use in children are lacking. To evaluate the safety and effectiveness of a 1-day PEG 3350 regimen for bowel preparation in children before colonoscopy. Retrospective review. Tertiary-care center. This study involved all children prescribed a 1-day PEG 3350 bowel preparation regimen before colonoscopy at our center in 2008. We reviewed medical records of patients (< or = 18 years of age) who underwent colonoscopy during 2008 and received the 1-day bowel preparation regimen. Adequate preparation for colonoscopy, success of colonoscopy, and factors associated with inadequate bowel preparation. Inclusion criteria were met by 272 patients. The median age of the children receiving the 1-day PEG 3350 preparation regimen was 13.7 years (range 1.08-17.92 years). Fifty-two percent were male; 48% were female. The most common indications for colonoscopy included abdominal pain (65%), bloody stools (29%), diarrhea (21%), and weight loss (18%). The 1-day bowel preparation regimen was effective in 253 patients (93%). The indication for colonoscopy, the age of the child, or a history of constipation did not significantly alter the success rate of colonoscopy. A retrospective study at one tertiary-care center. The 1-day PEG 3350 bowel preparation regimen is safe and effective and should be considered for use as preparation for colonoscopy in children. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. The Effectiveness of Short Message Service to Assure the Preparation-to-Colonoscopy Interval before Bowel Preparation for Colonoscopy

    PubMed Central

    Kim, Tae-Oh; Lee, Nae-Young; Kim, Hyoungjun; Seo, Eun Hee; Heo, Nae-Yun; Park, Seung Ha; Moon, Young-Soo

    2015-01-01

    Background/Aims. The preparation-to-colonoscopy (PC) interval is one of several important factors for the bowel preparation. Short message service (SMS) reminder from a cellular phone has been suggested to improve compliance in various medical situations. We evaluated the effectiveness of SMS reminders to assure the PC interval for colonoscopy. Methodology. This prospective randomized study was investigator blinded. In the No-SMS group, patients took the first 2 L polyethylene glycol (PEG) between 6 and 8 PM on the day before colonoscopy and the second 2 L PEG approximately 6 hours before the colonoscopy without SMS. In the SMS group, patients took first 2 L PEG in the same manner as the No-SMS group and the second 2 L PEG after receiving an SMS 6 hours before the colonoscopy. Results. The SMS group had a lower score than the No-SMS group, according to the Ottawa Bowel Preparation Scale (P < 0.001). Multivariate logistic regression analysis showed that compliance with diet instructions (odds ratio (OR) 2.109; 95% confidence interval (CI), 1.11–3.99, P = 0.022) and intervention using SMS ((OR) 2.329; 95% (CI), 1.34–4.02, P = 0.002) were the independent significant factors for satisfactory bowel preparation. Conclusions. An SMS reminder to assure PC interval improved the bowel preparation quality for colonoscopy with bowel preparation. PMID:25792978

  3. Transrectal-ultrasound prostatic biopsy preparation: rectal enema vs. mechanical bowel preparation.

    PubMed

    De Nunzio, Cosimo; Lombardo, Riccardo; Presicce, Fabrizio; Bellangino, Mariangela; Finazzi Agro, Enrico; Gambrosier, Matteo Bonetto; Trucchi, Alberto; Petta, Stefano; Tubaro, Andrea

    2015-01-01

    Transrectal prostate biopsy (TRUSbx) is the standard for the diagnosis of prostate cancer. Different bowel preparations are used for patients undergoing TRUSbx. The aim of our study was to compare two different bowel preparations for TRUSbx. From May 2012 and onwards, a selected group of men undergoing TRUS 12-core prostate biopsy were enrolled into a prospective database. Patients were randomized 1:1 to receive a rectal enema (Group A) the night before the procedure or polyethylene glycol 34.8 grams/4 liters of water the day before the procedure (Group B). A VAS scale to evaluate the patients' discomfort according to the two preparations was collected. The same antibiotic prophylaxis was performed in both groups. All complications were prospectively recorded and graded according to the Clavien Classification System (CCS). A total of 198 patients were consecutively enrolled. Mean age was 67.5 ±7.9 years, mean body mass index (BMI) was 27.1 ±4.2 Kg/m(2), mean PSA value was 9.3 ±12.6 ng/ml and the mean prostatic volume was 60.6 ±29 ml. 97 patients were enrolled in Group A and 101 in Group B. Overall post-biopsy morbidity rate was 60%. No significant differences for low-grade and high-grade complications was observed between the two groups. Patients receiving the rectal enema presented with a significantly lower VAS score (3.1 ±1.1 vs. 5.9 ±1.7; p = 0.02). Our study confirmed that a rectal enema should be considered as the standard bowel preparation in patients undergoing a TRUS biopsy; it is as effective as PEG and associated with less discomfort.

  4. Bowel preparation for pediatric colonoscopy: report of the NASPGHAN endoscopy and procedures committee.

    PubMed

    Pall, Harpreet; Zacur, George M; Kramer, Robert E; Lirio, Richard A; Manfredi, Michael; Shah, Manoj; Stephen, Thomas C; Tucker, Neil; Gibbons, Troy E; Sahn, Benjamin; McOmber, Mark; Friedlander, Joel; Quiros, J A; Fishman, Douglas S; Mamula, Petar

    2014-09-01

    Pediatric bowel preparation protocols used before colonoscopy vary greatly, with no identified standard practice. The present clinical report reviews the evidence for several bowel preparations in children and reports on their use among North American Society for Pediatric Gastroenterology, Hepatology, and Nutrition members. Publications in the pediatric literature for bowel preparation regimens are described, including mechanisms of action, efficacy and ease of use, and pediatric studies. A survey distributed to pediatric gastroenterology programs across the country reviews present national practice, and cleanout recommendations are provided. Finally, further areas for research are identified.

  5. Orange juice intake reduces patient discomfort and is effective for bowel cleansing with polyethylene glycol during bowel preparation.

    PubMed

    Choi, Hong Seok; Shim, Chan Sup; Kim, Gyu Won; Kim, Jung Seok; Lee, Sun-Young; Sung, In-Kyung; Park, Hyung Seok; Kim, Jeong Hwan

    2014-10-01

    Many patients report discomfort because of the unpleasant taste of bowel preparation solutions. This study aimed to determine whether adding orange juice to 2 L of polyethylene glycol plus ascorbic acid is effective for reducing patient discomfort and improving palatability during bowel preparation. This was a single-blinded, randomized controlled trial. The study was conducted at a tertiary referral hospital and a generalized hospital. Consecutive outpatients and inpatients were randomly allocated to drink 2 L of polyethylene glycol-ascorbic acid or 2 L of polyethylene glycol-ascorbic acid with orange juice in a single dose or a split dose. Tolerability, palatability score, willingness, and related adverse events were investigated by questionnaires. Bowel cleansing was rated using the Aronchick scale. Each score was graded on a 5-point scale. A total of 107 patients, 53 in the orange juice group and 54 in the polyethylene glycol-ascorbic acid group who underwent elective colonoscopy were enrolled. The palatability score (mean ± SD) was higher in the orange juice group than in the control group (2.36 ± 0.76 vs 1.78 ± 0.88; p = 0.005). Nausea was less frequent in the orange juice group (26.4% vs 59.3%; p = 0.001). Total amount of bowel preparation ingested was not significantly different between the groups (p = 0.44). The bowel preparation score (mean ± SD) was not significantly different (1.49 ± 0.80 vs 1.43 ± 0.77; p = 0.94). Willingness to repeat the same process was higher in the orange juice group (90.4% vs 66.7%; p = 0.003). This study is limited because only ambulatory patients were enrolled. Orange juice intake before drinking 2 L of polyethylene glycol-ascorbic acid for colonoscopy can reduce patient discomfort, resulting in improved acceptability and patient compliance. This method is as effective for bowel cleansing as polyethylene glycol.

  6. Importance of reporting segmental bowel preparation scores during colonoscopy in clinical practice

    PubMed Central

    Jain, Deepanshu; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury; Singhal, Shashideep

    2015-01-01

    AIM: To evaluate the impact of reporting bowel preparation using Boston Bowel Preparation Scale (BBPS) in clinical practice. METHODS: The study was a prospective observational cohort study which enrolled subjects reporting for screening colonoscopy. All subjects received a gallon of polyethylene glycol as bowel preparation regimen. After colonoscopy the endoscopists determined quality of bowel preparation using BBPS. Segmental scores were combined to calculate composite BBPS. Site and size of the polyps detected was recorded. Pathology reports were reviewed to determine advanced adenoma detection rates (AADR). Segmental AADR’s were calculated and categorized based on the segmental BBPS to determine the differential impact of bowel prep on AADR. RESULTS: Three hundred and sixty subjects were enrolled in the study with a mean age of 59.2 years, 36.3% males and 63.8% females. Four subjects with incomplete colonoscopy due BBPS of 0 in any segment were excluded. Based on composite BBPS subjects were divided into 3 groups; Group-0 (poor bowel prep, BBPS 0-3) n = 26 (7.3%), Group-1 (Suboptimal bowel prep, BBPS 4-6) n = 121 (34%) and Group-2 (Adequate bowel prep, BBPS 7-9) n = 209 (58.7%). AADR showed a linear trend through Group-1 to 3; with an AADR of 3.8%, 14.8% and 16.7% respectively. Also seen was a linear increasing trend in segmental AADR with improvement in segmental BBPS. There was statistical significant difference between AADR among Group 0 and 2 (3.8% vs 16.7%, P < 0.05), Group 1 and 2 (14.8% vs 16.7%, P < 0.05) and Group 0 and 1 (3.8% vs 14.8%, P < 0.05). χ2 method was used to compute P value for determining statistical significance. CONCLUSION: Segmental AADRs correlate with segmental BBPS. It is thus valuable to report segmental BBPS in colonoscopy reports in clinical practice. PMID:25852286

  7. Importance of reporting segmental bowel preparation scores during colonoscopy in clinical practice.

    PubMed

    Jain, Deepanshu; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury; Singhal, Shashideep

    2015-04-07

    To evaluate the impact of reporting bowel preparation using Boston Bowel Preparation Scale (BBPS) in clinical practice. The study was a prospective observational cohort study which enrolled subjects reporting for screening colonoscopy. All subjects received a gallon of polyethylene glycol as bowel preparation regimen. After colonoscopy the endoscopists determined quality of bowel preparation using BBPS. Segmental scores were combined to calculate composite BBPS. Site and size of the polyps detected was recorded. Pathology reports were reviewed to determine advanced adenoma detection rates (AADR). Segmental AADR's were calculated and categorized based on the segmental BBPS to determine the differential impact of bowel prep on AADR. Three hundred and sixty subjects were enrolled in the study with a mean age of 59.2 years, 36.3% males and 63.8% females. Four subjects with incomplete colonoscopy due BBPS of 0 in any segment were excluded. Based on composite BBPS subjects were divided into 3 groups; Group-0 (poor bowel prep, BBPS 0-3) n = 26 (7.3%), Group-1 (Suboptimal bowel prep, BBPS 4-6) n = 121 (34%) and Group-2 (Adequate bowel prep, BBPS 7-9) n = 209 (58.7%). AADR showed a linear trend through Group-1 to 3; with an AADR of 3.8%, 14.8% and 16.7% respectively. Also seen was a linear increasing trend in segmental AADR with improvement in segmental BBPS. There was statistical significant difference between AADR among Group 0 and 2 (3.8% vs 16.7%, P < 0.05), Group 1 and 2 (14.8% vs 16.7%, P < 0.05) and Group 0 and 1 (3.8% vs 14.8%, P < 0.05). χ(2) method was used to compute P value for determining statistical significance. Segmental AADRs correlate with segmental BBPS. It is thus valuable to report segmental BBPS in colonoscopy reports in clinical practice.

  8. A randomized controlled trial of an educational video to improve quality of bowel preparation for colonoscopy.

    PubMed

    Park, Jin-Seok; Kim, Min Su; Kim, HyungKil; Kim, Shin Il; Shin, Chun Ho; Lee, Hyun Jung; Lee, Won Seop; Moon, Soyoung

    2016-06-17

    High-quality bowel preparation is necessary for colonoscopy. A few studies have been conducted to investigate improvement in bowel preparation quality through patient education. However, the effect of patient education on bowel preparation has not been well studied. A randomized and prospective study was conducted. All patients received regular instruction for bowel preparation during a pre-colonoscopy visit. Those scheduled for colonoscopy were randomly assigned to view an educational video instruction (video group) on the day before the colonoscopy, or to a non-video (control) group. Qualities of bowel preparation using the Ottawa Bowel Preparation Quality scale (Ottawa score) were compared between the video and non-video groups. In addition, factors associated with poor bowel preparation were investigated. A total of 502 patients were randomized, 250 to the video group and 252 to the non-video group. The video group exhibited better bowel preparation (mean Ottawa total score: 3.03 ± 1.9) than the non-video group (4.21 ± 1.9; P < 0.001) and had good bowel preparation for colonoscopy (total Ottawa score <6: 91.6 % vs. 78.5 %; P < 0.001). Multivariate analysis revealed that males (odds ratio [OR] = 1.95, P = 0.029), diabetes mellitus patients (OR = 2.79, P = 0.021), and non-use of visual aids (OR = 3.09, P < 0.001) were associated with poor bowel preparation. In the comparison of the colonoscopic outcomes between groups, the polyp detection rate was not significantly different between video group and non-video group (48/250, 19.2 % vs. 48/252, 19.0 %; P = 0.963), but insertion time was significantly short in video group (5.5 ± 3.2 min) than non-video group (6.1 ± 3.7 min; P = 0.043). The addition of an educational video could improve the quality of bowel preparation in comparison with standard preparation method. Clinical Research Information Service KCT0001836 . The date of registration: March, 08

  9. Reduce costs and improve patient satisfaction with home pre-operative bowel preparations.

    PubMed

    Hearn, K; Dailey, M; Harris, M T; Bodian, C

    2000-01-01

    The results of a home-based preoperative bowel preparation, with and without the support of home care services, are compared with hospital-based preoperative bowel preparation. Length of stay, morbidity, and mortality rates; issues of patient satisfaction; and demographics are reported. The method and tools used in planning, implementing, and evaluating the home preoperative bowel preparation program are also shared. Other issues discussed are the healthcare market forces that promote an increased value of care. Economic and patient satisfaction considerations by employers, payers, and patients; the increasing influence of patient choice on healthcare provider selection and care setting preferences; the nursing workforce issues related to the impending shortage; and issues of regulatory and accrediting agencies are also discussed.

  10. Simethicone for small bowel preparation for capsule endoscopy: a systematic, single-blinded, controlled study.

    PubMed

    Albert, Jörg; Göbel, Christa-Maria; Lesske, Joachim; Lotterer, Erich; Nietsch, Hubert; Fleig, Wolfgang E

    2004-04-01

    Capsule endoscopy is a new imaging method for visualization of the entire small bowel. However, no standardized protocol for bowel preparation for capsule endoscopy has been evaluated. Capsule endoscopy was performed in 36 consecutive patients, all of whom fasted for 12 hours before ingestion of the capsule. Before capsule endoscopy, 18 patients received 80 mg simethicone and 18 had no supplemental medication for bowel preparation. Two observers, both experienced endoscopists, independently reviewed the examinations in a single-blinded and randomly assigned fashion. Mucosal visibility and intraluminal gas bubbles were assessed and graded by both observers. Bowel preparation with simethicone resulted in significantly better visibility because of fewer intraluminal bubbles (p<0.01). Interobserver agreement was excellent (r>/=0.8; k 0.78: 95% CI[0.57, 0.98] ). No adverse effect of simethicone was observed. Simethicone may be added to the routine preparation for capsule endoscopy to improve the visibility of small bowel mucosa.

  11. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    PubMed

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  12. Effect of Functional Status on the Quality of Bowel Preparation in Elderly Patients Undergoing Screening and Surveillance Colonoscopy

    PubMed Central

    Kumar, Akash; Lin, Lisa; Bernheim, Oren; Bagiella, Emilia; Jandorf, Lina; Itzkowitz, Steven H.; Shah, Brijen J.

    2016-01-01

    Background/Aims Optimal bowel preparation is essential for successful screening or for surveillance colonoscopy (SC). Inadequate bowel preparation is associated with older age, the male gender, and the presence of certain comorbidities. However, the association between patients’ functional status and bowel preparation quality has not been studied. We prospectively examined the relationship between functional status, namely, the ability to perform activities of daily living (ADLs) and ambulate, and the quality of bowel preparation in elderly patients undergoing SC. Methods Before undergoing SC, 88 elderly patients were surveyed regarding their functional status, specifically regarding their ability to perform ADLs and ambulate a quarter of a mile. Gastroenterologists then determined the quality of the bowel preparation, which was classified as either adequate or inadequate. Then, the frequency of inadequate bowel preparation in patients who did or did not experience difficulty performing ADLs and ambulating was calculated. Results Difficulty ambulating (unadjusted odds ratio [OR], 4.83; p<0.001), difficulty performing ADLs (OR, 2.93; p=0.001), and history of diabetes (OR, 2.88; p=0.007) were significant univariate predictors of inadequate bowel preparation. After adjusting for the above variables, only difficulty ambulating (adjusted OR, 5.78; p=0.004) was an independent predictor of inadequate bowel preparation. Conclusions Difficulty with ambulation is a strong predictor of inadequate bowel preparation in elderly patients undergoing SC. PMID:27021501

  13. Sphingosine-1-Phosphate Signaling in Inflammatory Bowel Disease.

    PubMed

    Nielsen, Ole Haagen; Li, Yuan; Johansson-Lindbom, Bengt; Coskun, Mehmet

    2017-04-01

    An unmet medical need exists for the development of targeted therapies for the treatment of inflammatory bowel disease (IBD) with easily administered and stable oral drugs, particularly as most patients on biologics [i.e., tumor necrosis factor (TNF) inhibitors and anti-integrins] are either primary non-responders or lose responsiveness during maintenance treatment. A new class of small molecules, sphingosine-1-phosphate (S1P) receptor modulators, has recently shown efficacy in IBD. Here we provide an overview of the mechanism of action of this novel treatment principle in the context of intestinal inflammation. The remarkable impact of therapeutic modulation of the S1P/S1P receptor axis reflects the complexity of the pathogenesis of IBD and the fact that S1P receptor modulation may be a logical therapeutic approach for the future management of IBD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Delivery of Instructions via Mobile Social Media App Increases Quality of Bowel Preparation.

    PubMed

    Kang, Xiaoyu; Zhao, Lina; Leung, Felix; Luo, Hui; Wang, Limei; Wu, Ji; Guo, Xiaoyang; Wang, Xiangping; Zhang, Linhui; Hui, Na; Tao, Qin; Jia, Hui; Liu, Zhiguo; Chen, Zhangqin; Liu, Junjun; Wu, Kaichun; Fan, Daiming; Pan, Yanglin; Guo, Xuegang

    2016-03-01

    Bowel preparation is closely linked to the quality of colonoscopy. We investigated whether delivery of instructions via a social media app increases the quality of colonoscopy by improving adequacy of bowel preparation. We performed a prospective study at 3 endoscopic centers in China of 770 colonoscopy outpatients (18-80 years old) with convenient access to Wechat (a widely used mobile social media app) from May through November 2014. Patients were randomly assigned to groups that received standard education along with delivery of interactive information via Wechat (n = 387) or standard education (controls, n = 383). The primary outcome was proportion of patients with adequate bowel preparation (Ottawa score <6). Secondary outcomes included rates of adenoma detection and cecal intubation, cecal intubation time, rates of incomplete compliance with instructions, and patient willingness to repeat bowel preparation. Demographic features were comparable between the groups. A higher proportion of patients in the group that received social media instruction had adequate bowel preparation than the control group (82.2% vs 69.5%, P < .001). Among patients with successful colonoscopies, the group that received social media instruction had lower mean total and segmental Ottawa scores (P < .05). A higher proportion of patients receiving social media instruction also had cecal intubation (97.2% vs 93.2% in controls, P = .014) and were found to have adenomas (18.6% vs 12.0% in controls, P = .012). Instruction via a mobile social media app, in conjunction with regular instruction, increases subjective measures of adequacy of bowel preparation. Use of the app significantly increased the proportion of patients with successful cecal intubation and in whom adenomas were detected, indicating increased quality of colonoscopy. ClinicalTrials.gov number: NCT02140827. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  15. Constipation, fiber intake and non-compliance contribute to inadequate colonoscopy bowel preparation: a prospective cohort study.

    PubMed

    Fang, Jun; Fu, Hong Yu; Ma, Dan; Wang, Dong; Liu, Ya Ping; Wang, Yun Feng; Zhu, Chun Ping; Qian, Wei; Bai, Yu; Li, Zhao Shen

    2016-07-01

    Adequate bowel preparation is important for colonoscopy. Currently available evidence on the determinants of poor bowel preparation is largely derived from studies in Western countries. We aimed to identify the risk factors for inadequate bowel preparation for colonoscopy in the Chinese population. In this single-center study, patients admitted to the Outpatient Department between March 2013 and December 2015 and had indications for colonoscopy were prospectively enrolled. Questionnaires were administered to the patients. Their characteristics and procedure-related parameters such as procedure time were recorded. Bowel preparation was assessed using Boston bowel preparation scale score. A total of 409 patients with a mean age of 48.8 ± 12.9 years were enrolled in the study, 60.9% of whom were men. On univariate analysis, poor educational level (P = 0.020), chronic constipation (P = 0.001), taking no physical exercise after medication (P < 0.001), a high-fiber diet during the 24-h period immediately preceding the colonoscopy (P < 0.001), incomplete intake of medication (P < 0.001), the passage of yellow or dark stools before colonoscopy (P < 0.001), waiting time (P = 0.001) and stool frequency after medication (P = 0.048) were significantly associated with inadequate bowel preparation. On multivariate analysis, chronic constipation [odds ratio (OR) 2.05, 95% confidence interval (CI) 1.31-3.23, P = 0.002], incomplete intake of the medication (OR 2.77, 95% CI 1.47-5.21, P = 0.002) and a high-fiber diet within 24 h before colonoscopy (OR 2.15, 95% CI 1.40-3.28, P < 0.001) were independent risk factors for inadequate bowel preparation. Chronic constipation, poor compliance with treatment and high-fiber diet were predictors of poor bowel preparation. Patients with these risk factors require more effective strategies for bowel preparation. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital

  16. Gastrografin as an alternative booster to sodium phosphate in colon capsule endoscopy: safety and efficacy pilot study*

    PubMed Central

    Togashi, Kazutomo; Fujita, Tomoki; Utano, Kenichi; Waga, Eriko; Katsuki, Shinichi; Isohata, Noriyuki; Endo, Shungo; Lefor, Alan K.

    2015-01-01

    Background and study aims: Sodium phosphate is a key component of bowel preparation regimen for colon capsule endoscopy (CCE), but may cause serious complications. The aim of this study is to evaluate the use of Gastrografin, substituted for sodium phosphate, in CCE bowel preparation. Patients and methods: In total, 29 patients (median age 64 years; 23 females) underwent CCE, covered by the national health insurance system of Japan. All had a history of laparotomy and/or previously incomplete colonoscopy. On the day before examination, patients ingested 1 L of polyethylene glycol + ascorbic acid with 0.5 L of water in the evening, and again the same laxative on the morning of examination. After capsule ingestion, 50 mL of Gastrografin diluted with 0.9 L of magnesium citrate was administered, and then repeated after 1 hour. Results: The capsule excretion rate was 97 % (28/29). The median colon transit time was 2 hours 45 minutes and rapid transit (< 40 minutes) through the colon occurred in one patient (3.4 %). Bowel cleansing level was adequate in 90 % of patients. The polyp (≥ 6 mm) detection rate was 52 %. Diluted Gastrografin was well tolerated by patients. No adverse events occurred. Conclusion: Gastrografin can be an alternative to sodium phosphate in CCE bowel preparation regimen. PMID:26716132

  17. Combination oral and mechanical bowel preparations decreases complications in both right and left colectomy.

    PubMed

    Midura, Emily F; Jung, Andrew D; Hanseman, Dennis J; Dhar, Vikrom; Shah, Shimul A; Rafferty, Janice F; Davis, Bradley R; Paquette, Ian M

    2018-03-01

    Before elective colectomy, many advocate mechanical bowel preparation with oral antibiotics, whereas enhanced recovery pathways avoid mechanical bowel preparations. The optimal preparation for right versus left colectomy is also unclear. We sought to determine which strategy for bowel preparation decreases surgical site infection (SSI) and anastomotic leak (AL). Elective colectomies from the National Surgical Quality Improvement Program colectomy database (2012-2015) were divided by (1) type of bowel preparation: no preparation (NP), mechanical preparation (MP), oral antibiotics (PO), or mechanical and oral antibiotics (PO/MP); and (2) type of colonic resection: right, left, or segmental colectomy. Univariate and multivariate analyses identified predictors of SSI and AL, and their risk-adjusted incidence was determined by logistic regression. When analyzed as the odds ratio compared with NP, the PO and PO/MP groups were associated with a decrease in SSI (PO = 0.70 [0.55-0.88] and PO/MP = 0.47 [0.42-0.53]; P < .01). Use of PO/MP was associated with a decrease in SSI across all types of resections (right colectomy = 0.40 [0.33-0.50], left colectomy = 0.57 [0.47-0.68], and segmental colectomy = 0.43 (0.34-0.54); P < .01). Similarly, use of PO/MP was associated with a decrease in AL in left colectomy = 0.50 ([0.37-0.69]; P < .01) and segmental colectomy = 0.53 ([0.36-0.80]; P < .01). Mechanical bowel preparation with oral antibiotics is the preferred preoperative preparation strategy in elective colectomy because of decreased incidence of SSI and AL. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. [Colonic lavage prior to colonoscopy: comparable outcomes of two polyethylene-glycol preparations and a sodium-phosphate solution].

    PubMed

    Felt-Bersma, R J; Kooyman, G; Kuipers, E J

    2004-01-24

    Comparison of three cleansing solutions for bowel preparation prior to colonoscopy. Prospective, randomized. 140 outpatients referred for colonoscopy were randomized into three groups for cleansing with 4 litres PEG 4000, 4 litres PEG 3350 or with 90 ml sodium phosphate with an additional 2.5 litres of fluid. Between cleansing and colonoscopy, patients filled in a questionnaire concerning taste, abdominal cramps and tolerance to the procedure. Blinded to the type of cleansing the endoscopist scored the effects on the colon and rectosigmoid, and made the endoscopic diagnosis. All data were available for 127 of the 140 patients (50 men, 77 women), mean age 51 years (range 18-96). Comparison between the three groups showed no statistically significant difference in the opinion of the patients concerning taste, abdominal cramps and tolerance of lavage. The endoscopist's scoring of total colon cleansing showed a small reduction in colon cleanliness when using sodium phosphate compared to PEG 3350 (p = 0.03). No differences were found between the two PEG solutions. Combining both PEG solutions and comparing them with the sodium-phosphate solution showed fewer abdominal cramps (p = 0.07) with sodium phosphate and a cleaner colon with PEG (p = 0.07). Women complained slightly more of abdominal cramps and were slightly less tolerant of the procedure than men. Previous colonic surgery did not influence the results. Patients with diverticula were older, but no other effect of cleansing was found. The three preparations are comparable in their cleansing effect and tolerance by the patient.

  19. Online Educational Video Improves Bowel Preparation and Reduces the Need for Repeat Colonoscopy Within Three Years.

    PubMed

    Hayat, Umar; Lee, Peter J W; Lopez, Rocio; Vargo, John J; Rizk, Maged K

    2016-11-01

    Unsatisfactory bowel preparation has been reported in up to 33% of screening colonoscopies. Patients' lack of understanding about how a good bowel preparation can be achieved is one of the major causes. Patient education has been explored as a possible intervention to improve this important endpoint and has yielded mixed results. We compared the proportion of satisfactory bowel preparations and adenoma detection rates between patients who viewed and did not view an educational video on colonoscopy. An educational video on colonoscopy, accessible via the Internet, was issued to all patients with planned procedures between 2010 and 2014. Viewing status of the video was verified through a unique code linked to each patient's medical record. Excellent, good, or adequate bowel preparations were defined as "satisfactory," whereas fair, poor, or inadequate bowel preparations were defined as "unsatisfactory." A total of 2530 patients undergoing their first outpatient screening colonoscopy were included; 1251 patients viewed the educational video and 1279 patients did not see the video. Multivariate analysis revealed higher rates of satisfactory bowel preparation in the educational video group (92.3% [95% confidence interval [CI], 84.8-96.3] vs 87.4% [95% CI, 76.4-93.7], P <.001). Need for a repeat colonoscopy within 3 years was also higher in patients who did not see the video (6.6% [95% CI, 2.8-14.7] vs 3.3% [95% CI 1.3-7.8], P <.001). Patient-centered educational video improves bowel preparation quality and may reduce the need for an earlier repeat procedure in patients undergoing screening colonoscopy. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Impact of bowel preparation on surveillance colonoscopy interval.

    PubMed

    Singhal, Shashideep; Virk, Muhammad Asif; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury

    2014-07-01

    Atpresent there are no guidelines for colonoscopy surveillance interval in subjects with unsatisfactory bowel preparation. Study was designed to compare outcomes of repeat colonoscopy at different surveillance intervals in patients with unsatisfactory preparation on index exam. Ten thousand nine hundred and eight colonoscopies were done during the study period. Patients with index colonoscopy exam complete up to cecum but suboptimal bowel prep were included. Two hundred and ninety-seven patients met the inclusion criteria. The interval for repeat colonoscopy was <1 year in 38.5%, 1-2 years in 33.3%, 2-3 years in 16.7%, and 3-5 years in 11.5% subjects. Adenoma detection rate (ADR) was 24%, high-risk adenoma detection rate (HR-ADR) was 8.4%, and colorectal cancer detection rate was 1.7%. The HR-ADR based on surveillance intervals <1 year, 1-2 years, 2-3 years, and 3-5 years was 8%, 7.9%, 2%, and 19.4%, respectively. The HR-ADR was significantly higher at surveillance interval 3-5 years (p < 0.05). Colonoscopies repeated at interval >3 years showed a significant HR-ADR. The study indicates that a surveillance interval of 3 years can be reasonable for subjects having an index colonoscopy with suboptimal/fair/poor bowel prep and complete colon examination. Colonoscopy should be repeated earlier if symptoms develop.

  1. Combination of Oral Antibiotics and Mechanical Bowel Preparation Reduces Surgical Site Infection in Colorectal Surgery.

    PubMed

    Ohman, Kerri A; Wan, Leping; Guthrie, Tracey; Johnston, Bonnie; Leinicke, Jennifer A; Glasgow, Sean C; Hunt, Steven R; Mutch, Matthew G; Wise, Paul E; Silviera, Matthew L

    2017-10-01

    Surgical site infections (SSI) are a common complication after colorectal surgery. An infection prevention bundle (IPB) was implemented to improve outcomes. A standardized IPB that included the administration of oral antibiotics with a mechanical bowel preparation, preoperative shower with chlorhexidine, hair removal and skin preparation in holding, antibiotic wound irrigation, and a "clean-closure" protocol was implemented in January 2013. Data from the American College of Surgeons NSQIP were analyzed at a single academic institution to compare pre-IPB and post-IPB SSI rates. In January 2014, a prospective database was implemented to determine compliance with individual IPB elements and their effect on outcomes. For the 24 months pre-IPB, the overall SSI rate was 19.7%. During the 30 months after IPB implementation, the SSI rate decreased to 8.2% (p < 0.0001). A subset of 307 patients was identified in both NSQIP and our prospective compliance databases. Elements of IPB associated with decreased SSI rates included preoperative shower with chlorhexidine (4.6% vs 16.2%; p = 0.005), oral antibiotics (3.4% vs 15.4%; p < 0.001), and mechanical bowel preparation (4.4% vs 14.3%; p = 0.008). Patients who received a full bowel preparation of both oral antibiotics and a mechanical bowel preparation had a 2.7% SSI rate compared with 15.8% for all others (p < 0.001). On multivariate analysis, full bowel preparation was independently associated with significantly fewer SSI (adjusted odds ratio 0.2; 95% CI 0.1 to 0.9; p = 0.006). Implementation of an IPB was successful in decreasing SSI rates in colorectal surgery patients. The combination of oral antibiotics with a mechanical bowel preparation was the strongest predictor of decreased SSI. Copyright © 2017 American College of Surgeons. All rights reserved.

  2. Bowel preparations for capsule endoscopy: a comparison between simethicone and magnesium citrate.

    PubMed

    Esaki, Motohiro; Matsumoto, Takayuki; Kudo, Tetsuji; Yanaru-Fujisawa, Ritsuko; Nakamura, Shotaro; Iida, Mitsuo

    2009-01-01

    Bowel preparation for capsule endoscopy (CE) has not been standardized. This study aimed to compare CE images between patients prepared by simethicone and those prepared by magnesium citrate. Retrospective analysis of case series of our hospital from 2004 to 2007. Single center. CE images of 75 patients receiving bowel preparation either by 200 mg of simethicone (n=39) or by 34 g of magnesium citrate (n=36) were retrospectively investigated. Grades of fluid transparency and mucosal invisibility by air bubbles and food residue were compared between the 2 preparations. Capsule transit time, frequency of positive findings, and interobserver variations between 2 observers were also investigated. Image quality and diagnostic yield of CE. Fluid transparency in the first and the third time segments of the small intestine was better in patients prepared by magnesium citrate than in those prepared by simethicone (P= .001 and P= .03, respectively). On the other hand, mucosal invisibility was not different in any part of the small intestine between the 2 groups. Neither gastric transit time nor small-bowel transit time was different between the 2 groups. The diagnostic yield of CE correlated significantly with fluid transparency (P= .04), but it did not correlate with mucosal invisibility. Single-center retrospective study. Magnesium citrate seems to be a recommended preparation for CE compared with simethicone. The fluid transparency, rather than the mucosal invisibility, may be a factor associated with the diagnostic yield of CE.

  3. Small bowel preparations for capsule endoscopy with mannitol and simethicone: a prospective, randomized, clinical trial.

    PubMed

    Chen, Hong-bin; Huang, Yue; Chen, Su-yu; Song, Hui-wen; Li, Xiao-lin; Dai, Dong-lin; Xie, Jia-tia; He, Song; Zhao, Yuan-yuan; Huang, Chun; Zhang, Sheng-jun; Yang, Lin-na

    2011-04-01

    There is no consensus concerning small bowel preparation before capsule endoscopy (CE). This study evaluated the effects of 4 regimens on small bowel cleansing and diagnostic yield. Patients were randomly divided into 4 groups. Group A consumed a clear liquid diet after lunch on the day before CE, followed by overnight fasting. Group B took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In group C, the same regimen was taken at 20:00 hours on the day before and at 05:00 hours on the day of CE. In group D, in addition to the group C regimen, 20 mL oral simethicone was taken 30 minutes before CE. Two hundred patients were prospectively enrolled, and 7 were excluded from the final analysis because of incomplete small bowel transit. No significant difference was noted among the 4 groups for small bowel transit time. Bowel preparation in group D was significantly better than for the other regimens for overall cleansing of the proximal small bowel, and showed improved overall cleansing of the distal small bowel when compared with 10-hours overnight fasting. Pathological lesions of the proximal and distal small bowel were, respectively, achieved in 82 and 74 patients, mostly distributed in group D. Small bowel preparation that involves split-dose oral mannitol plus single-dose simethicone for CE can improve mucosal visualization and subsequent diagnostic yield when compared with 10-hours overnight fasting.

  4. Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy.

    PubMed

    Spada, Cristiano; Riccioni, Maria E; Familiari, Pietro; Spera, Gianluca; Pirozzi, Giuseppe A; Marchese, Michele; Bizzotto, Alessandra; Ingrosso, Marcello; Costamagna, Guido

    2010-05-01

    Small-bowel contents can hamper the quality of video-capsule endoscopy (VCE). No standardized protocol has been proposed and overnight fasting remains the proposed preparation for VCE. The aim was to evaluate the effects of 2 regimens of bowel preparation on small intestine cleansing, diagnostic yield and capsule transit times. This is a prospective, randomized, blinded, and controlled study. Sixty patients referred for VCE were randomized into 2 groups. Group A ingested 2l of a polyethylene glycol and simethicone solution 16h before VCE. Group B were instructed to consume a fibre-free diet and allowed to consume clear liquids the day before VCE. The small-bowel cleansing was graded as "complete" if the entire wall was assessable, "incomplete" if more than 50% of the wall was visible, and "insufficient" if less than 50% of the wall was visible. In group A, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 42%, 39% and 19% of cases respectively. In group B, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 43%, 33% and 24% of cases respectively. No significant differences were observed between the two groups, regarding small-bowel cleansing level (p=0.65). No differences were also observed in the diagnostic yield (48.2%, 13.8% and 38% vs 65.5%, 6.9% and 27.6% of positive, suspicious and no findings respectively, in groups A and B [p=0.39]) and small-bowel transit times (mean 288min and 299 min in groups A and B respectively [p=0.70]). The results of the present study do not support the use of 2l of a polyethylene glycol and simethicone solution before VCE. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  5. A Prospective Randomized Controlled Trial of AJG522 versus Standard PEG + E as Bowel Preparation for Colonoscopy

    PubMed Central

    Sagawa, Toshihiko; Tomizawa, Taku; Mizuide, Masafumi; Yasuoka, Hidetoshi; Shimoyama, Yasuyuki; Kakizaki, Satoru; Kawamura, Osamu; Kusano, Motoyasu; Yamada, Masanobu

    2015-01-01

    Polyethylene glycol- (PEG-) based bowel preparations for colonoscopies are often poorly tolerated due to the large volumes of fluid intake required. We compared low-volume “modified” PEG + ascorbic acid (AJG522) with standard PEG with electrolytes (PEG + E) in addition to a stimulant laxative and an agent to improve bowel function for the bowel cleansing before colonoscopy to evaluate its efficacy, safety, and acceptability. Outpatients scheduled to undergo colonoscopy were randomized to receive either AJG522 or PEG + E. Bowel cleansing conditions were assessed via macroscopic fecal findings by blinded and independent investigators. A survey of the patients' feedback regarding the preparation was conducted by questionnaire. Successful cleansing was achieved in all cases, except for 4 cases in the PEG + E group, at 3 hours after taking the preparation. The fecal properties were significantly clearer in the AJG522 group than in the PEG + E group at 2 hours after taking each preparation (P = 0.013). Although the total liquid volume of the bowel preparation was not reduced, the AJG522 preparation could significantly reduce the required volume of the preparation (P < 0.0001). Moreover, the patients in the AJG522 group had better acceptability (P = 0.010). There were no significant differences in the safety profiles between groups (UMIN000013892). PMID:25688357

  6. Thermo-tolerant phosphate-solubilizing microbes for multi-functional biofertilizer preparation.

    PubMed

    Chang, Cheng-Hsiung; Yang, Shang-Shyng

    2009-02-01

    In order to prepare the multi-functional biofertilizer, thermo-tolerant phosphate-solubilizing microbes including bacteria, actinomycetes, and fungi were isolated from different compost plants and biofertilizers. Except Streptomycesthermophilus J57 which lacked pectinase, all isolates possessed amylase, CMCase, chitinase, pectinase, protease, lipase, and nitrogenase activities. All isolates could solubilize calcium phosphate and Israel rock phosphate; various isolates could solubilize aluminum phosphate, iron phosphate, and hydroxyapatite. During composting, biofertilizers inoculated with the tested microbes had a significantly higher temperature, ash content, pH, total nitrogen, soluble phosphorus content, and germination rate than non-inoculated biofertilizer; total organic carbon and carbon-to-nitrogen ratio showed the opposite pattern. Adding these microbes can shorten the period of maturity, improve the quality, increase the soluble phosphorus content, and enhance the populations of phosphate-solubilizing and proteolytic microbes in biofertilizers. Therefore, inoculating thermo-tolerant phosphate-solubilizing microbes into agricultural and animal wastes represents a practical strategy for preparing multi-functional biofertilizer.

  7. A critical evaluation and a search for the ideal colonoscopic preparation.

    PubMed

    Arora, Manish; Senadhi, Viplove; Arora, Deepika; Weinstock, Joyce; Dubin, Ethan; Okolo, Patrick I; Dutta, Sudhir K

    2013-04-01

    The aim of this study was to evaluate the efficacy of various bowel preparations in accomplishing colonic cleansing for optimal mucosal visualization during colonoscopy. The study included a cohort of 980 patients who underwent colonoscopy at our endoscopy center within the last 3 years. All of the study patients were subdivided into four groups. Each group included 245 patients, all receiving a different type of bowel preparation. The bowel preparations used in this study included: magnesium citrate (Group I), a combination of oral sodium phosphate (fleets) and powder PEG-3350 (Group II), powder polyethylene glycol-3350 (PEG-3350 powder for Group III), and oral sodium phosphate (fleets for Group IV). A Colon Prep Score (CPS) was devised to compare the quality of the different bowel preparations used. The colonoscopy results from all of these patients were tabulated and analyzed statistically and expressed as mean ± 1 standard deviation. Statistical analysis was performed using a one way ANOVA with Holm-Sidak method for intergroup analysis. Group I patients received magnesium citrate and had a mean CPS ± 1 SD of 3.11 ± 0.91. Group II patients (fleets and powder PEG-3350 combination) achieved a CPS of 3.37 ± 1.16. The patients in Group III (powder PEG-3350) actually showed the highest mean CPS of 3.44 ± 1.12. Group IV patients who used oral sodium phosphate alone reached a mean CPS of 3.23 ± 1.01. Group III patients (powder PEG-3350 only) demonstrated a statistically higher CPS (P<0.0006) in colon cleansing as compared to Group I patients (magnesium citrate). Similarly, Group II patients (oral sodium phosphate and powder PEG-3350 combination) also showed improved colon cleansing statistically (P<0.006) as compared to Group I patients (magnesium citrate). Overall, all four colon preparations achieved an average CPS greater than 3.0 indicating clinically adequate colonic cleansing. However, powder PEG-3350 alone and in combination with oral sodium phosphate was

  8. Video on Diet Before Outpatient Colonoscopy Does Not Improve Quality of Bowel Preparation: A Prospective, Randomized, Controlled Trial.

    PubMed

    Rice, Sean C; Higginbotham, Tina; Dean, Melanie J; Slaughter, James C; Yachimski, Patrick S; Obstein, Keith L

    2016-11-01

    Successful outpatient colonoscopy (CLS) depends on many factors including the quality of a patient's bowel preparation. Although education on consumption of the pre-CLS purgative can improve bowel preparation quality, no study has evaluated dietary education alone. We have created an educational video on pre-CLS dietary instructions to determine whether dietary education would improve outpatient bowel preparation quality. A prospective randomized, blinded, controlled study of patients undergoing outpatient CLS was performed. All patients received a 4 l polyethylene glycol-based split-dose bowel preparation and standard institutional pre-procedure instructions. Patients were then randomly assigned to an intervention arm or to a no intervention arm. A 4-min educational video detailing clear liquid diet restriction was made available to patients in the intervention arm, whereas those randomized to no intervention did not have access to the video. Patients randomized to the video were provided with the YouTube video link 48-72 h before CLS. An attending endoscopist blinded to randomization performed the CLS. Bowel preparation quality was scored using the Boston Bowel Preparation Scale (BBPS). Adequate preparation was defined as a BBPS total score of ≥6 with all segment scores ≥2. Wilcoxon rank-sum and Pearson's χ 2 -tests were performed to assess differences between groups. Ninety-two patients were randomized (video: n=42; control: n=50) with 47 total video views being tallied. There were no demographic differences between groups. There was no statistically significant difference in adequate preparation between groups (video=74%; control=68%; P=0.54). The availability of a supplementary patient educational video on clear liquid diet alone was insufficient to improve bowel preparation quality when compared with standard pre-procedure instruction at our institution.

  9. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy

    PubMed Central

    Pontone, Stefano; Angelini, Rita; Standoli, Monica; Patrizi, Gregorio; Culasso, Franco; Pontone, Paolo; Redler, Adriano

    2011-01-01

    AIM: To investigate the effectiveness of low-volume plus ascorbic acid [polyethylene glycol plus ascorbic acid (PEG + Asc)] and high-volume plus simethicone [polyethylene glycol plus simethicone (PEG + Sim)] bowel preparations. METHODS: A total of one hundred and forty-four outpatients (76 males), aged from 20 to 84 years (median age 59.5 years), who attended our Department, were divided into two groups, age and sex matched, and underwent colonoscopy. Two questionnaires, one for patients reporting acceptability and the other for endoscopists evaluating bowel cleansing effectiveness according to validated scales, were completed. Indications, timing of examination and endoscopical findings were recorded. Biopsy forceps were used as a measuring tool in order to determine polyp endoscopic size estimation. Difficulty in completing the preparation was rated in a 5-point Likert scale (1 = easy to 5 = unable). Adverse experiences (fullness, cramps, nausea, vomiting, abdominal pain, headache and insomnia), number of evacuations and types of activities performed during preparation (walking or resting in bed) were also investigated. RESULTS: Seventy-two patients were selected for each group. The two groups were age and sex matched as well as being comparable in terms of medical history and drug therapies taken. Fourteen patients dropped out from the trial because they did not complete the preparation procedure. Ratings of global bowel cleansing examinations were considered to be adequate in 91% of PEG + Asc and 88% of PEG + Sim patients. Residual Stool Score indicated similar levels of amount and consistency of residual stool; there was a significant difference in the percentage of bowel wall visualization in favour of PEG + Sim patients. In the PEG + Sim group, 12 adenomas ≤ 10 mm diameter (5/left colon + 7/right colon) vs 9 (8/left colon + 1/right colon) in the PEG + Asc group were diagnosed. Visualization of small lesions seems to be one of the primary advantages of the

  10. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy.

    PubMed

    Pontone, Stefano; Angelini, Rita; Standoli, Monica; Patrizi, Gregorio; Culasso, Franco; Pontone, Paolo; Redler, Adriano

    2011-11-14

    To investigate the effectiveness of low-volume plus ascorbic acid [polyethylene glycol plus ascorbic acid (PEG + Asc)] and high-volume plus simethicone [polyethylene glycol plus simethicone (PEG + Sim)] bowel preparations. A total of one hundred and forty-four outpatients (76 males), aged from 20 to 84 years (median age 59.5 years), who attended our Department, were divided into two groups, age and sex matched, and underwent colonoscopy. Two questionnaires, one for patients reporting acceptability and the other for endoscopists evaluating bowel cleansing effectiveness according to validated scales, were completed. Indications, timing of examination and endoscopical findings were recorded. Biopsy forceps were used as a measuring tool in order to determine polyp endoscopic size estimation. Difficulty in completing the preparation was rated in a 5-point Likert scale (1 = easy to 5 = unable). Adverse experiences (fullness, cramps, nausea, vomiting, abdominal pain, headache and insomnia), number of evacuations and types of activities performed during preparation (walking or resting in bed) were also investigated. Seventy-two patients were selected for each group. The two groups were age and sex matched as well as being comparable in terms of medical history and drug therapies taken. Fourteen patients dropped out from the trial because they did not complete the preparation procedure. Ratings of global bowel cleansing examinations were considered to be adequate in 91% of PEG + Asc and 88% of PEG + Sim patients. Residual Stool Score indicated similar levels of amount and consistency of residual stool; there was a significant difference in the percentage of bowel wall visualization in favour of PEG + Sim patients. In the PEG + Sim group, 12 adenomas ≤ 10 mm diameter (5/left colon + 7/right colon) vs 9 (8/left colon + 1/right colon) in the PEG + Asc group were diagnosed. Visualization of small lesions seems to be one of the primary advantages of the PEG + Sim preparation

  11. Elective colorectal surgery without bowel preparation: a historical control and case-matched study.

    PubMed

    Pitot, D; Bouazza, E; Chamlou, R; Van de Stadt, J

    2009-01-01

    Although full bowel preparation, including mechanical washout and non-absorbable antibiotherapy, has been considered for decades as a prerequisite to any elective colorectal surgery, recent literature has suggested that this habit was perhaps unjustified. The aim of this study was to assess the safety of ileocolic, colocolic and colorectal anastomosis in the absence of pre-operative mechanical bowel preparation. During a 1-year period, 59 consecutive patients underwent elective colorectal surgery with ileocolic, colocolic or colorectal anastomosis without any pre-operative preparation. This "non-prepared group" (NPG) was compared to a "control group" (CG) composed of the previous 127 consecutive cases of classically managed patients. To improve the statistical power we also compared the NPG to a "match-controlled group" (MCG) of 59 patients within the CG. Primary end-points were anastomotic leakage and abdominal infections. Secondary end-points were oral diet resume time and hospital stay. There were no differences between the 3 groups for age, gender, BMI, immunodepression status, anastomosis site and suture technique. There were no differences between NPG and CG or MCG for anastomotic leakage (3.5%, 4.7% and 6.8% respectively, NPG/CG p = 0.68 and NPG/MCG p = 0.4) or for infectious abdominal complications. Mean diet resume time was 1.4 (1-5) days in the NPG versus 3.4 (1-19) days in the CG and 3.1 (1-6) days in the MCG (p < 0.00001). Median length of postoperative hospital stay was 5 (2-81) days in the NPG versus 8 (4-100) and 8 (4-100) in the CG and the MCG respectively. In accordance with the recent literature, the present experience does not show any benefit of mechanical bowel preparation in elective colorectal resection. This suggests that bowel preparation could be omitted before this type of surgery.

  12. Prospective evaluation of 1-day polyethylene glycol-3350 bowel preparation regimen in children.

    PubMed

    Abbas, Mazen I; Nylund, Cade M; Bruch, Carol J; Nazareno, Luzviminda G; Rogers, Philip L

    2013-02-01

    The aim of the present study was to evaluate efficacy, safety, and tolerability of a pediatric colonoscopy bowel preparation regimen composed of polyethylene glycol-3350 (PEG-3350) and a sports drink completed in a few hours. A prospective, open-label trial of a colonoscopy bowel preparation in children ages 8 to 18 years that included 238 g of PEG-3350 mixed with 1.9 L of Gatorade completed in a few hours. Efficacy was determined using the Boston Bowel Preparation Scale. Basic metabolic profiles and questionnaires were obtained that assessed for safety, adverse effects, tolerability, and patient acceptability. Forty-six patients completed the study. Patients were predominately boys (56.5%) with a mean age of 14.50 years (SD ± 2.9 years). Forty-three (93.5%) were able to complete the regimen. All of the colonoscopies were completed to the cecum and 84% had terminal ileum visualization. Seventy-seven percent were found to be effective preparations. Nausea/vomiting were the most common reported adverse effect (60%) followed by abdominal pain/cramping (44%) and fatigue/weakness (40%). Overall, the regimen was acceptable with 1 exception being the large volume to drink. There were no clinically significant changes in basic metabolic profiles, although there was a statistically significant decrease in the mean potassium (0.16 mEq/L; P = 0.016), blood urea nitrogen (2.68 mg/dL; P < 0.0001), and carbon dioxide (1.89 mmol/L; P < 0.0001). This study demonstrated that PEG-3350 + Gatorade administered in a few hours is an effective, safe, and moderately tolerable bowel preparation regimen for colonoscopy in children.

  13. Consortium inoculum of five thermo-tolerant phosphate solubilizing Actinomycetes for multipurpose biofertilizer preparation.

    PubMed

    Nandimath, Arusha P; Karad, Dilip D; Gupta, Shantikumar G; Kharat, Arun S

    2017-10-01

    Alkaline pH of the soil facilitates the conversion of phosphate present in phosphate fertilizer applied in the field to insoluble phosphate which is not available to plants. Problem of soluble phosphate deficiency arises, primarily due to needless use of phosphate fertilizer. We sought to biofertilizer with the thermo-tolerant phosphate solubilizing actinomycetes consortium that could convert insoluble phosphate to soluble phosphate at wider temperature range. In the present investigation consortium of five thermo-tolerant phosphate solubilizing actinomycetes was applied for preparation of inoculum to produce multipurpose bio-fertilizer. Phosphates solubilizing thermo-tolerant 32 actinomycetes strains were processed for identification with the use of PIBWIN software and were screened for phosphate solubilizing activity. Amongst these five actinomycetes were selected on the basis of their ability to produce cellulase, chitinase, pectinase, protease, lipase, amylase and phosphate solubilizing enzymes. Ability to produce these enzymes at 28°C and 50°C were examined. Biofertilizer was prepared by using agricultural waste as a raw material. While preparation of bio-fertilizer the pH decreased from 7.5 to 4.3 and temperature increased up to 74°C maximum at the end of 4 th week and in subsequent week it started to decline gradually till it reached around 50°C, which was found to be stable up to eighth week. This thermo-tolerant actinomycetes consortium released soluble phosphate of up to 46.7 μg ml -1 . As the mesophilic organisms die out at high temperature of composting hence thormo-tolerant actinomycetes would be the better substitute for preparation of phosphate solubilizing bio-fertilizer with added potential to degrade complex macromolecules in composting.

  14. Improvements in safety and recovery following cystectomy: reassessing the role of pre-operative bowel preparation and interventions to speed return of post-operative bowel function.

    PubMed

    Zaid, Harras B; Kaffenberger, Samuel D; Chang, Sam S

    2013-04-01

    For radical cystectomy, historical practice trends have favored the use of preoperative bowel preparations to reduce complications, including surgical site infections, ileus, and anastomotic leaks. However, emerging data has questioned this practice. Postoperative cystectomy care also remains in flux, as new pharmacologic agents that may potentiate earlier return of bowel function are studied. We review the current literature with regards to preoperative and postoperative cystectomy bowel management.

  15. Consortium inoculum of five thermo-tolerant phosphate solubilizing Actinomycetes for multipurpose biofertilizer preparation

    PubMed Central

    Nandimath, Arusha P.; Karad, Dilip D.; Gupta, Shantikumar G.; Kharat, Arun S.

    2017-01-01

    Background and Objectives: Alkaline pH of the soil facilitates the conversion of phosphate present in phosphate fertilizer applied in the field to insoluble phosphate which is not available to plants. Problem of soluble phosphate deficiency arises, primarily due to needless use of phosphate fertilizer. We sought to biofertilizer with the thermo-tolerant phosphate solubilizing actinomycetes consortium that could convert insoluble phosphate to soluble phosphate at wider temperature range. Materials and Methods: In the present investigation consortium of five thermo-tolerant phosphate solubilizing actinomycetes was applied for preparation of inoculum to produce multipurpose bio-fertilizer. Phosphates solubilizing thermo-tolerant 32 actinomycetes strains were processed for identification with the use of PIBWIN software and were screened for phosphate solubilizing activity. Results: Amongst these five actinomycetes were selected on the basis of their ability to produce cellulase, chitinase, pectinase, protease, lipase, amylase and phosphate solubilizing enzymes. Ability to produce these enzymes at 28°C and 50°C were examined. Biofertilizer was prepared by using agricultural waste as a raw material. While preparation of bio-fertilizer the pH decreased from 7.5 to 4.3 and temperature increased up to 74°C maximum at the end of 4th week and in subsequent week it started to decline gradually till it reached around 50°C, which was found to be stable up to eighth week. This thermo-tolerant actinomycetes consortium released soluble phosphate of up to 46.7 μg ml−1. Conclusion: As the mesophilic organisms die out at high temperature of composting hence thormo-tolerant actinomycetes would be the better substitute for preparation of phosphate solubilizing bio-fertilizer with added potential to degrade complex macromolecules in composting. PMID:29296275

  16. Randomised clinical trial: low-volume bowel preparation for colonoscopy - a comparison between two different PEG-based formulations.

    PubMed

    Repici, A; Cestari, R; Annese, V; Biscaglia, G; Vitetta, E; Minelli, L; Trallori, G; Orselli, S; Andriulli, A; Hassan, C

    2012-10-01

    Low-volume bowel preparations with polyethylene glycol (PEG) have been shown to provide an equivalent cleansing with improved tolerability as compared with standard PEG bowel preparation for colonoscopy. A new iso-osmotic sulphate-free formulation of PEG-Citrate-Simethicone (PEG-CS) in combination with bisacodyl has been recently developed. To compare the quality of bowel cleansing with PEG-CS with bisacodyl vs. PEG-Ascorbate (PEG-ASC) in adult out-patients undergoing colonoscopy. Randomised, observer-blind, parallel group study in adult out-patients undergoing colonoscopy in five Italian centres. Both preparations were taken the evening before the procedure. Subjects were instructed to take 2-4 tablets of 5 mg bisacodyl at 16:00 hours and 2 L of PEG-CS at 20:00 hours or 2 L of PEG-ASC plus 1 L of additional water the day before colonoscopy. Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale (≥6 scores were considered as 'clinical success'), and mucosal visibility according to a 3-point scale. Tolerability, acceptability and compliance were also evaluated. Four hundred and eight patients were randomly allocated to PEG-CS and bisacodyl (n = 204, male patient 48%, mean age 59.1 years) or PEG-ASC (n = 204, male patient 51%, age 59.4 years). In the planned per-protocol analysis, the rate of successful preparation was 79.1% following PEG-CS with bisacodyl, and 70% following PEG-ASC (P < 0.05). Mucosal visibility was evaluated as optimal in 56.1% in the PEG-CS and bisacodyl and 46.3% in the PEG-ASC group (P < 0.05). There were no serious adverse events (AE) in each of the two experimental groups. Two subjects in the PEG-ASC group discontinued the study because of AE. Polyethylene glycol-Citrate-Simethicone in combination with bisacodyl was more effective for bowel cleansing than PEG-ASC for out-patient colonoscopy. Tolerability, safety, acceptability and compliance of the two low-volume bowel preparations were similar. © 2012

  17. Tolerability, safety, and efficacy of PEG 3350 as a 1-day bowel preparation in children.

    PubMed

    Walia, Ritu; Steffen, Rita; Feinberg, Lisa; Worley, Sarah; Mahajan, Lori

    2013-02-01

    The aim of the study was to evaluate the tolerability, safety, and efficacy of polyethylene glycol (PEG) 3350 without electrolytes as a 1-day bowel preparation for colonoscopy in children. A prospective study of 45 children undergoing colonoscopy prescribed PEG 3350 without electrolytes mixed with a commercial electrolyte beverage was performed. Patients <45 kg received 136 g of PEG 3350 without electrolytes mixed in 32 ounces of Gatorade. Patients ≥ 45 kg were given 255 g of PEG 3350 without electrolytes in 64 ounces of Gatorade A basic metabolic panel was performed at the time of the clinic visit and just before colonoscopy. Patients completed a survey related to bowel preparation. Endoscopists graded bowel preparation and noted the proximal extent of the examination. A total of 44 patients (14 ± 3 years) completed the study. One patient was excluded due to protocol breach. All subjects reported the preparation was easy (61%) or tolerable (39%). Adverse events included nausea (34%), abdominal pain (23%), vomiting (16%), abdominal distension (20%), bloating (23%), and dizziness (7%). Although significant changes in serum glucose and CO2 were noted, no therapeutic interventions were indicated. Significant changes in sodium, potassium chloride, blood urea nitrogen, or creatinine did not occur. Colonic preparation was rated as excellent in 23%, good in 52%, fair in 23%, and poor in 2% of patients. Intubation of the ileum was successful in 100%. One-day bowel preparation with high dose PEG 3350 mixed with commercial electrolyte solution is tolerable, safe, and effective in children before colonoscopy.

  18. Impact of reinforced education by telephone and short message service on the quality of bowel preparation: a randomized controlled study.

    PubMed

    Lee, Yoo Jin; Kim, Eun Soo; Choi, Jae Hyuk; Lee, Kyung In; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2015-11-01

    High quality bowel preparation is essential for successful colonoscopy. This study aimed to assess the impact of reinforced education by telephone or short message service (SMS) on the quality of bowel preparation. A prospective, endoscopist-blinded, randomized, controlled study was conducted. Reinforced education groups received additional education via reminders by telephone or SMS 2 days before colonoscopy. The primary outcome was the quality of the bowel preparation according to the Boston Bowel Preparation Scale (BBPS). The secondary outcomes included polyp detection rate (PDR), adenoma detection rate (ADR), tolerance, and subjective feelings of patients. A total of 390 patients were included. Total BBPS score was significantly higher in the reinforced education groups than in the control group (mean [SD] telephone vs. 7.1 [1.2] vs. 6.3 [1.4], P < 0.001; SMS vs. 6.8 [1.3] vs. 6.3 [1.4], P = 0.027). Between the two interventions, there was no significant difference in total BBPS score. PDR and ADR were not different among groups. Reinforced education groups showed lower anxiety and better tolerance compared with controls. A preparation-to-colonoscopy time of > 6 hours and < 80 % of the purgative ingested were independent factors associated with inadequate bowel preparation (BBPS < 5), whereas re-education by telephone was inversely related to inadequate bowel preparation. SMS was the optimal education modality, and was as effective as telephone reminders for the quality of bowel preparation. A reinforced educational approach via telephone or SMS should be individualized, depending on the resource availability of each clinical practice. ClinicalTrials.gov (NCT01911052). © Georg Thieme Verlag KG Stuttgart · New York.

  19. Use of mechanical bowel preparation and oral antibiotics for elective colorectal procedures in children: is current practice evidence-based?

    PubMed

    Pennington, Elliot C; Feng, Christina; St Peter, Shawn D; Islam, Saleem; Goldin, Adam B; Abdullah, Fizan; Rangel, Shawn J

    2014-06-01

    It is well established through randomized trials that oral antibiotics given with or without a mechanical bowel preparation (MBP) prior to colorectal procedures reduce complications, while MBP given alone provides no benefit. We aimed to characterize trends surrounding bowel preparation in children and determine whether contemporary practice is evidence-based. Retrospective analysis of patients undergoing colorectal procedures at 42 children's hospitals (1/2/2007-12/31/2011) was performed. Patients were analyzed for diagnosis, pre-admission status, and inpatient bowel preparation. Bowel preparation was considered evidence-based if oral antibiotics were utilized with or without a MBP. 49% of all patients were pre-admitted (n=5,473), and the most common diagnoses were anorectal malformations (55%), inflammatory bowel disease (26%), and Hirschsprung's Disease (19%). The most common preparation approaches were MBP alone (54.3%), MBP+oral antibiotics (18.8%), and oral antibiotics alone (4.2%), although significant variation was found in hospital-specific rates for each approach (MBP alone: 0-96.1%, MBP+oral antibiotics: 0-83.6%, orals alone: 0-91.6%, p<0.0001). Only 22.9% of all patients received an evidence-based preparation (range by hospital: 0-92.3%, p<0.0001), and this rate decreased significantly during the five-year study period (27.6% in 2007 vs. 17.3% in 2011, p<0.0001). According to the best available clinical evidence, less than a quarter of all children pre-admitted for elective colorectal procedures receive a bowel preparation proven to reduce infectious complications. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Efficacy of prokinetics with a split-dose of polyethylene glycol in bowel preparation for morning colonoscopy: a randomized controlled trial.

    PubMed

    Kim, Hyoung Jun; Kim, Tae Oh; Shin, Bong Chul; Woo, Jae Gon; Seo, Eun Hee; Joo, Hee Rin; Heo, Nae-Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo; Shin, Jin-Yong; Lee, Nae Young

    2012-01-01

    Currently, a split-dose of polyethylene glycol (PEG) is the mainstay of bowel preparation due to its tolerability, bowel-cleansing action, and safety. However, bowel preparation with PEG is suboptimal because residual fluid reduces the polyp detection rate and requires a more thorough colon inspection. The aim of our study was to demonstrate the efficacy of a sufficient dose of prokinetics on bowel cleansing together with split-dose PEG. A prospective endoscopist-blinded study was conducted. Patients were randomly allocated to two groups: prokinetic with split-dose PEG or split-dose PEG alone. A prokinetic [100 mg itopride (Itomed)], was administered twice simultaneously with each split-dose of PEG. Bowel-cleansing efficacy was measured by endoscopists using the Ottawa scale and the segmental fluidity scale score. Each participant completed a bowel preparation survey. Mean scores from the Ottawa scale, segmental fluid scale, and rate of poor preparation were compared between both groups. Patients in the prokinetics with split-dose PEG group showed significantly lower total Ottawa and segmental fluid scores compared with patients in the split-dose of PEG alone group. A sufficient dose of prokinetics with a split-dose of PEG showed efficacy in bowel cleansing for morning colonoscopy, largely due to the reduction in colonic fluid. Copyright © 2012 S. Karger AG, Basel.

  1. Impact of gum chewing on the quality of bowel preparation for colonoscopy: an endoscopist-blinded, randomized controlled trial.

    PubMed

    Fang, Jun; Wang, Shu-Ling; Fu, Hong-Yu; Li, Zhao-Shen; Bai, Yu

    2017-07-01

    Gum chewing can accelerate motility in the GI tract; clinical studies suggested gum chewing can reduce postoperative ileus. However, no trial has investigated the effect of gum chewing on bowel preparation for colonoscopy in addition to polyethylene glycol (PEG). The objective of this study was to investigate whether gum chewing before colonoscopy can increase the quality of bowel preparation. This was a single-center, randomized controlled trial. Consecutive patients undergoing colonoscopy were randomized to the gum group or the control group. Patients in the gum group chewed sugar-free gum every 2 hours for 20 minutes each time from the end of drinking 2 L of PEG to the beginning of colonoscopy. Patients in the control group only received 2 L of PEG before colonoscopy. The quality of bowel preparation, procedure time, adenoma detection rate, patients' tolerance, and adverse events were compared. Three hundred patients were included in the study (150 in the control group, 150 in the gum group). More than 90% of patients in both groups were satisfied with the process of bowel preparation, and the incidence of adverse events was comparable in the 2 groups (41.3% vs 46.0%, P = .42). The mean Boston Bowel Preparation Scale score was 6.2 ± 1.4 and 6.1 ± 1.2 in the control group and the gum group, respectively, and the difference between the 2 groups was not significant (P = .51). This study indicates that gum chewing does not improve the quality of bowel preparation for colonoscopy, but it can improve patients' satisfaction with the process of bowel preparation and does not have negative effects on cleanliness. (Clinical trials registration number: NCT02507037.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Methods for preparation of nanocrystalline rare earth phosphates for lighting applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Comanzo, Holly Ann; Manoharan, Mohan; Martins Loureiro, Sergio Paulo

    Disclosed here are methods for the preparation of optionally activated nanocrystalline rare earth phosphates. The optionally activated nanocrystalline rare earth phosphates may be used as one or more of quantum-splitting phosphor, visible-light emitting phosphor, vacuum-UV absorbing phosphor, and UV-emitting phosphor. Also disclosed herein are discharge lamps comprising the optionally activated nanocrystalline rare earth phosphates provided by these methods.

  3. A randomized, controlled trial of oral sulfate solution plus polyethylene glycol as a bowel preparation for colonoscopy.

    PubMed

    Rex, Douglas K; McGowan, John; Cleveland, Mark vB; Di Palma, Jack A

    2014-09-01

    No bowel preparation for colonoscopy is optimal with regard to efficacy, safety, and tolerability. New options for bowel preparation are needed. To compare a new hybrid preparation consisting of a reduced dose of oral sulfate solution (OSS) plus 2 L of sulfate-free electrolyte lavage solution (SF-ELS) with 2 low-volume preparations based on polyethylene glycol electrolyte lavage solution (PEG-ELS). Two randomized, controlled trials. Twenty-four U.S. centers. A total of 737 outpatients undergoing colonoscopy. In study 1, OSS plus SF-ELS was given as a split dose, and in study 2, OSS plus SF-ELS was given in its entirety the evening before colonoscopy. In study 1, the active control was 2 L of PEG-ELS plus ascorbic acid (PEG-EA) given as a split dose. In study 2, the control was 10 mg of bisacodyl plus 2 L of SF-ELS taken the evening before colonoscopy. Rates of successful (good or excellent) bowel preparation. In study 1, the rates of successful (excellent or good) preparation with OSS plus SF-ELS and PEG-EA were identical at 93.5% for split-dose preparation. OSS plus SF-ELS was noninferior to PEG-EA (P < .001). In study 2, OSS plus SF-ELS resulted in successful preparation in 89.8% of patients compared with 83.5% with bisacodyl plus SF-ELS in a same-day preparation regimen. OSS plus SF-ELS was noninferior to bisacodyl plus SF-ELS (P <.001). In study 1, vomiting was more frequent with OSS plus SF-ELS (13.5% vs 6.7%; P = .042), and bloating was rated worse with PEG-EA (P = .025). In study 2, overall discomfort was rated worse with OSS plus SF-ELS (mean score 2.1 vs 1.8; P = .032). There were no deaths in either study and no serious adverse events considered related to the preparation. Bowel cleansing was not scored by colon segment. Adenoma detection was not compared between the regimens. OSS plus SF-ELS is a new, safe, and effective bowel preparation for colonoscopy. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All

  4. Preparation before colonoscopy: a randomized controlled trial comparing different regimes.

    PubMed

    Jansen, Sita V; Goedhard, Jelle G; Winkens, Bjorn; van Deursen, Cees Th B M

    2011-10-01

    A good bowel preparation is essential for optimal visualization of the large intestine. Several preparations with a difference in composition and volume are available. We compared five methods for bowel cleansing quality and patients' acceptability. Adult ambulatory outpatients scheduled for elective colonoscopy were randomized to receive 4-l polyethylene glycol (PEG) solution (Klean-prep), 2-l PEG solution+ascorbic acid (Moviprep), or a sodium phosphate (NaP) solution, Phosphoral. Patients with the PEG solutions were also randomized to receive simethicone (Aeropax), to investigate whether this improves the bowel cleansing efficacy. Before colonoscopy patients completed a questionnaire about the acceptability and tolerability of the preparation. Endoscopists blinded to the type of preparation gave a bowel cleansing score. Data were available for 461 patients. 2-l PEG+ascorbic acid was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid and colon. NaP was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid but inferior for the whole colon. Compliance was significantly less in the group with 4-l PEG compared with the 2-l PEG and NaP group. No difference was found for abdominal cramps. Taste was significantly better in the 2-l PEG group. Simethicone did not improve the bowel cleansing quality. 2-l PEG+ascorbic acid was noninferior to the 4-l PEG solution in bowel cleansing quality and was better in taste and compliance. NaP was inferior to 4-l PEG in bowel cleansing quality. Addition of simethicone gave no improvement.

  5. Laparoscopic colorectal resections with and without routine mechanical bowel preparation: A comparative study.

    PubMed

    Chan, Miu Yee; Foo, Chi Chung; Poon, Jensen Tung Chung; Law, Wai Lun

    2016-08-01

    The benefit of mechanical bowel preparation (MBP) in patients undergoing laparoscopic colorectal resections remains a question. This study aimed to evaluate the effect of omitting MBP on patients undergoing laparoscopic bowel resections. The outcomes of patients who underwent elective colorectal resections for cancer of colon and upper rectum without MBP were compared to a retrospective cohort who had MBP. There were 97 patients in the No-MBP group and 159 patients in the MBP group. Their mean age, operative risk, tumor size and stage of disease were similar. There were no significant differences in operative time and estimated blood loss. The anastomotic leakage rate was 1.0% in the No-MBP group and 0.6% in the MBP group, (p = 1.00). Wound infection rate were 4.1% and 3.8% in the No-MBP group and the MBP group respectively (p = 1.00). Overall surgical morbidity rate was 11.3% in the No-MBP group and 8.2% in the MBP group (p = 0.40). Conversion rates were 5.2% in the No-MBP group and 6.9% in the MBP group, (p = 0.57). The omission of mechanical bowel preparation does not increase surgical morbidities in patients undergoing laparoscopic bowel resections. It also has no effect on operating time and conversion rate.

  6. The Impact of Patient Education with a Smartphone Application on the Quality of Bowel Preparation for Screening Colonoscopy.

    PubMed

    Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub

    2017-09-01

    Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p =0.007 by t -test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group.

  7. A Clear Liquid Diet Is Not Mandatory for Polyethylene Glycol-Based Bowel Preparation for Afternoon Colonoscopy in Healthy Outpatients

    PubMed Central

    Jung, Yoon Suk; Seok, Hyo Sun; Song, Chang Seok; Kim, Seong Eun; Lee, Suck Ho; Eun, Chang Soo; Han, Dong Soo; Kim, Yong Soo; Lee, Chang Kyun

    2013-01-01

    Background/Aims A dietary regimen consisting of a clear liquid diet (CLD) for at least 24 hours is recommended for colonoscopy preparation. However, this requirement results in problems in patient compliance with bowel preparation. The aim of this study was to evaluate the efficacy of a CLD compared with a regular diet (RD) for colonoscopy preparation using a polyethylene glycol (PEG) solution. Methods This was a multicenter, randomized, investigator-blind prospective study. A total of 801 healthy outpatients undergoing afternoon colonoscopy were randomized to either a CLD or RD in addition to a 4 L PEG regimen. Results The quality of bowel cleansing was not different between the CLD and RD groups in terms of the proportion with excellent or good preparation. In addition, no significant differences were observed between the two groups for polyp and adenoma detection rates and overall adverse events. Good compliance with bowel preparation was higher in the RD group than in the CLD group. Conclusions A CLD for a full day prior to colonoscopy should not be mandatory for PEG-based bowel preparation. Dietary education concerning the avoidance of high-fiber foods for 3 days before colonoscopy is sufficient, at least for healthy outpatients. PMID:24312709

  8. Two-day bowel preparation with polyethylene glycol 3350 and bisacodyl: a new, safe, and effective regimen for colonoscopy in children.

    PubMed

    Phatak, Uma P; Johnson, Susanne; Husain, Sohail Z; Pashankar, Dinesh S

    2011-07-01

    To assess the safety, efficacy, and acceptance of a 2-day bowel preparation with polyethylene glycol (PEG) 3350 without electrolytes and bisacodyl for colonoscopy in children. In a prospective study, 111 children of mean age 11.9 years were given 2 g/kg of PEG and a 5-mg tablet of bisacodyl daily for 2 days before colonoscopy. Stool frequency, consistency, and adverse effects were monitored for the duration of the bowel preparation. Compliance and quality of colonic preparation were assessed on the day of the colonoscopy. The average daily stool frequency increased from a baseline of 2, to 4* on day 1, and 6.5* on day 2 of the bowel preparation (*P < 0.001 for difference vs baseline). The colonic preparations were rated as excellent or good in 92% and 93% of the patients in the right and left colon, respectively. Adverse effects were mild nausea (19%), abdominal pain (11%), and vomiting (4%). The compliance was rated as excellent in 95% of the patients. A 2-day bowel preparation with PEG and bisacodyl is safe, effective, and well accepted for colonoscopy in children without any major adverse effects.

  9. Multicenter, randomized study to optimize bowel preparation for colon capsule endoscopy

    PubMed Central

    Kastenberg, David; Jr, Wilmot C Burch; Romeo, David P; Kashyap, Pankaj K; Pound, David C; Papageorgiou, Neophytos; Sainz, Ignacio Fernández-Urien; Sokach, Carly E; Rex, Douglas K

    2017-01-01

    AIM To assess the cleansing efficacy and safety of a new Colon capsule endoscopy (CCE) bowel preparation regimen. METHODS This was a multicenter, prospective, randomized, controlled study comparing two CCE regimens. Subjects were asymptomatic and average risk for colorectal cancer. The second generation CCE system (PillCam® COLON 2; Medtronic, Yoqneam, Israel) was utilized. Preparation regimens differed in the 1st and 2nd boosts with the Study regimen using oral sulfate solution (89 mL) with diatrizoate meglumine and diatrizoate sodium solution (“diatrizoate solution”) (boost 1 = 60 mL, boost 2 = 30 mL) and the Control regimen oral sulfate solution (89 mL) alone. The primary outcome was overall and segmental colon cleansing. Secondary outcomes included safety, polyp detection, colonic transit, CCE completion and capsule excretion ≤ 12 h. RESULTS Both regimens had similar cleansing efficacy for the whole colon (Adequate: Study = 75.9%, Control = 77.3%; P = 0.88) and individual segments. In the Study group, CCE completion was superior (Study = 90.9%, Control = 76.9%; P = 0.048) and colonic transit was more often < 40 min (Study = 21.8%, Control = 4%; P = 0.0073). More Study regimen subjects experienced adverse events (Study = 19.4%, Control = 3.4%; P = 0.0061), and this difference did not appear related to diatrizoate solution. Adverse events were primarily gastrointestinal in nature and no serious adverse events related either to the bowel preparation regimen or the capsule were observed. There was a trend toward higher polyp detection with the Study regimen, but this did not achieve statistical significance for any size category. Mean transit time through the entire gastrointestinal tract, from ingestion to excretion, was shorter with the Study regimen while mean colonic transit times were similar for both study groups. CONCLUSION A CCE bowel preparation regimen using oral sulfate solution and diatrizoate solution as a boost agent is effective, safe, and

  10. Beverage intake preference and bowel preparation laxative taste preference for colonoscopy

    PubMed Central

    Laiyemo, Adeyinka O; Burnside, Clinton; Laiyemo, Maryam A; Kwagyan, John; Williams, Carla D; Idowu, Kolapo A; Ashktorab, Hassan; Kibreab, Angesom; Scott, Victor F; Sanderson, Andrew K

    2015-01-01

    AIM: To examine whether non-alcoholic beverage intake preferences can guide polyethylene glycol (PEG)-based bowel laxative preparation selection for patients. METHODS: We conducted eight public taste test sessions using commercially procured (A) unflavored PEG, (B) citrus flavored PEG and (C) PEG with ascorbate (Moviprep). We collected characteristics of volunteers including their beverage intake preferences. The volunteers tasted the laxatives in randomly assigned orders and ranked the laxatives as 1st, 2nd, and 3rd based on their taste preferences. Our primary outcome is the number of 1st place rankings for each preparation. RESULTS: A total of 777 volunteers completed the study. Unflavored PEG was ranked as 1st by 70 (9.0%), flavored PEG by 534 (68.7%) and PEG with ascorbate by 173 (22.3%) volunteers. Demographic, lifestyle characteristics and beverage intake patterns for coffee, tea, and carbonated drinks did not predict PEG-based laxative preference. CONCLUSION: Beverage intake pattern was not a useful guide for PEG-based laxative preference. It is important to develop more tolerable and affordable bowel preparation laxatives for colonoscopy. Also, patients should taste their PEG solution with and without flavoring before flavoring the entire gallon as this may give them more opportunity to pick a pattern that may be more tolerable. PMID:26261736

  11. Beverage intake preference and bowel preparation laxative taste preference for colonoscopy.

    PubMed

    Laiyemo, Adeyinka O; Burnside, Clinton; Laiyemo, Maryam A; Kwagyan, John; Williams, Carla D; Idowu, Kolapo A; Ashktorab, Hassan; Kibreab, Angesom; Scott, Victor F; Sanderson, Andrew K

    2015-08-06

    To examine whether non-alcoholic beverage intake preferences can guide polyethylene glycol (PEG)-based bowel laxative preparation selection for patients. We conducted eight public taste test sessions using commercially procured (A) unflavored PEG, (B) citrus flavored PEG and (C) PEG with ascorbate (Moviprep). We collected characteristics of volunteers including their beverage intake preferences. The volunteers tasted the laxatives in randomly assigned orders and ranked the laxatives as 1(st), 2(nd), and 3(rd) based on their taste preferences. Our primary outcome is the number of 1(st) place rankings for each preparation. A total of 777 volunteers completed the study. Unflavored PEG was ranked as 1(st) by 70 (9.0%), flavored PEG by 534 (68.7%) and PEG with ascorbate by 173 (22.3%) volunteers. Demographic, lifestyle characteristics and beverage intake patterns for coffee, tea, and carbonated drinks did not predict PEG-based laxative preference. Beverage intake pattern was not a useful guide for PEG-based laxative preference. It is important to develop more tolerable and affordable bowel preparation laxatives for colonoscopy. Also, patients should taste their PEG solution with and without flavoring before flavoring the entire gallon as this may give them more opportunity to pick a pattern that may be more tolerable.

  12. The Impact of Patient Education with a Smartphone Application on the Quality of Bowel Preparation for Screening Colonoscopy

    PubMed Central

    Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub

    2017-01-01

    Background/Aims Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. Methods In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. Results The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p=0.007 by t-test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. Conclusions In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group. PMID:28669148

  13. A feasibility study on laxative-free bowel preparation for virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Liang, Zhengrong; Chen, Dongqing; Wax, Mark; Lakare, Sarang; Li, Lihong; Anderson, Joseph; Kaufman, Arie; Harrington, Donald

    2005-04-01

    Objective: To investigate the feasibility of laxative-free bowel preparation to relieve the patient stress in colon cleansing for virtual colonoscopy. Materials and Methods: Three different bowel-preparation protocols were investigated by 60 study cases from 35 healthy male volunteers. All the protocols utilize low-residue diet for two days and differ in diet for the third day - the day just prior to image acquisition in the fourth day morning. Protocol Diet-1 utilizes fluid or liquid diet in the third day, Diet-2 utilizes a food kit, and Diet-3 remains the low-residue diet. Oral contrast of barium sulfate (2.1%, 250 ml) was added respectively to the dinner in the second day and the three meals in the third day. Two doses of MD-Gastroview (60 ml) were ingested each in the evening of the third day and in the morning before image acquisition. Images were acquired by a single-slice detector spiral CT (computed tomography) scanner with 5 mm collimation, 1 mm reconstruction, 1.5-2.0:1.0 pitch, 100-150 mA, and 120 kVp after the colons were inflated by CO2. The contrasted colonic residue materials were electronically removed from the CT images by specialized computer-segmentation algorithms. Results: By assumptions that the healthy young volunteers have no polyp and the image resolution is approximately 4 mm, a successful electronic cleansing is defined as "no more than five false positives and no removal of a colon fold part greater than 4 mm" for each study case. The successful rate is 100% for protocol Diet-1, 77% for Diet-2 and 57% for Diet-3. Conclusion: A laxative-free bowel preparation is feasible for virtual colonoscopy.

  14. Efficacy and safety of sodium phosphate for colon cleansing in type 2 diabetes mellitus.

    PubMed

    Ozturk, Nevin Akcaer; Gokturk, Huseyin Savas; Demir, Mehmet; Unler, Gulhan Kanat; Gur, Gurden; Yilmaz, Ugur

    2010-11-01

    The need for colonoscopy is common among diabetic patients. However, there are no standards per se for bowel preparation in patients with type 2 diabetes. In this study, we evaluated the efficacy, safety, and tolerability of sodium phosphate (NaP), and the quality of bowel cleansing in relation to glycemic control and late complications. A total of 50 consecutive type 2 diabetic patients and 50 non-diabetic patients underwent bowel preparation by NaP. Fasting blood glucose, sodium (Na), potassium (K), calcium (Ca), phosphorus (P), magnesium, and creatinine levels were measured on the procedure day. Patients were given a tolerability questionnaire regarding symptoms. With regard to bowel preparation quality, optimal bowel cleansing was achieved in 35 (70%) diabetic and 47 (94%) non-diabetic patients (P = 0.002). Abdominal pain or discomfort during and an hour after the procedure was similar in both groups (P >0.05). The changes in Na, K, Ca, P and creatinine levels after NaP use did not reach statistical significance between the groups (P >0.05). In the diabetic patients, there was a significant correlation between the quality of bowel cleansing and mean age, duration of diabetes mellitus, level of hemoglobin A1c (HbA1c), fasting blood glucose level, and diabetic late complications (P <0.05). These data suggest that NaP is safe and tolerable in diabetic patients, but the quality of bowel cleansing is worse than in non-diabetic patients. These observations support the concept that the quality of bowel cleansing in those with type 2 diabetes is closely related to the duration and regulation of the disease and the presence of late complications.

  15. Improving the quality of colonoscopy bowel preparation using a smart phone application: a randomized trial.

    PubMed

    Lorenzo-Zúñiga, Vicente; Moreno de Vega, Vicente; Marín, Ingrid; Barberá, Marta; Boix, Jaume

    2015-07-01

    Getting ready for a colonoscopy is difficult and involves many steps. Information given to patients is very important for adherence to treatment. We created a novel smart phone application (SPA) aimed to increase bowel preparation quality and patient satisfaction. We carried out a prospective, endoscopist-blinded, randomized, controlled trial. We enrolled 260 outpatient (58% female, age range 21-75 years) owners of a smartphone. Patients were allocated to two different protocols: instructions provided by SPA (SPA group; n = 108) or written instructions with visual aids (control group; n = 152). All procedures were carried out in the afternoon and patients received the same purgative regimen (2 L polyethylene glycol (PEG) solution plus ascorbic acid), in a full-dose same-day regimen. The study was designed to detect an improvement in quality of bowel preparation using the Harefield Cleansing Scale (HCS) scale. Effect of protocol on patient satisfaction was assessed with a specific questionnaire at the time of colonoscopy. Proportion of patients who obtained successful bowel preparation for colonoscopy (HCS A or B) was significantly higher in the SPA group than in the control group (100% vs 96.1%, respectively; P = 0.037). Mean global HCS scores were similar in both groups. Patient-reported tolerability and overall experience with the prescribed bowel preparation were significantly higher for the SPA group than for the control group. Successful cleansing and patient acceptability with the use of SPA were superior to written instructions in outpatients submitted for colonoscopy using 2 L PEG solution plus ascorbic acid. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  16. Low-volume bowel preparation is inferior to standard 4 1 polyethylene glycol.

    PubMed

    Haapamäki, Markku M; Lindström, Monica; Sandzén, Birger

    2011-03-01

    Four liters or more of orally taken polyethylene glycol solution (PEG) has proved to be an effective large-bowel cleansing method prior to colonoscopy. The problem has been the large volume of fluid and its taste, which is unacceptable to some examinees. We aimed to investigate the effectiveness of 2 l PEG combined with senna compared with 4 l PEG for bowel preparation. The design was a single-center, prospective, randomized, investigator-blinded study with parallel assignment, in the setting of the Endoscopy Unit of Umeå University Hospital. Outpatients (n = 490) scheduled for colonoscopy were enrolled. The standard-volume arm received 4 l PEG, and the low-volume arm received 36 mg senna glycosides in tablets and 2 l PEG. The cleansing result (primary endpoint) was assessed by the endoscopist using the Ottawa score. The patients rated the subjective grade of ease of taking the bowel preparation. Analysis was on an intention-to-treat basis. There were significantly more cases with poor or inadequate bowel cleansing after the low-volume alternative with senna and 2 l PEG (22/203) compared with after 4 l PEG (8/196, p = 0.027). The low-volume alternative was better tolerated by the examinees: 119/231 rated the treatment as easy to take compared with 88/238 in the 4 l PEG arm (p = 0.001). 4 l PEG treatment is better than 36 mg senna and 2 l PEG as routine colonic cleansing before colonoscopy because of fewer failures.

  17. Revisiting the potential signs of colorectal cancer on contrast-enhanced computed tomography without bowel preparation.

    PubMed

    Naqvi, Jawad; Hosmane, Sharath; Lapsia, Snehal

    2015-10-01

    Colorectal cancer (CRC) is the second most common cause of cancer death in the US. Earlier detection can allow treatment with curative intent and improve prognosis. Optical and virtual colonoscopy are widely used in screening for colonic polyps and in the investigation of suspected CRC. However, contrast-enhanced computed tomography (CT) is still performed to investigate various non-specific abdominal complaints. Hence, a significant number of CRC are identified on contrast-enhanced CT without bowel preparation. We describe several signs, which when present in tandem, raise suspicion of CRC, and may warrant further investigation with optical colonoscopy. These include an intraluminal mass, eccentric or circumferential wall thickening >3 mm, focal wall enhancement, pericolic fat stranding, a cluster of >3 local lymph nodes, and enlarged lymph nodes >10 mm in short axis. Multiplanar evaluation of the bowel should be performed on all CT abdominal studies, including those without bowel preparation, to identify subtle features of CRC.

  18. Colorectal cancer screening in patients with spinal cord injury yields similar results to the general population with an effective bowel preparation: a retrospective chart audit.

    PubMed

    Teng, Brandon J; Song, Shawn H; Svircev, Jelena N; Dominitz, Jason A; Burns, Stephen P

    2018-03-01

    Retrospective chart audit. To compare adequacy of colonoscopy bowel preparation and diagnostic findings between persons with SCI receiving an extended inpatient bowel preparation and the general population. Veterans Affairs Puget Sound Healthcare System, Seattle, WA, USA. We reviewed an electronic database of all colonoscopies performed at a tertiary Veterans Affairs medical center between 7/12/13 and 15/10/15. Patients with SCI received a multi-day bowel preparation with magnesium citrate, and 8-10 liters of polyethylene glycol-3350 and electrolyte colonic lavage solution (PEG-ELS) over two and one half days. The control population received a standard bowel preparation consisting of magnesium citrate and 4 liters of PEG-ELS over 1 day. Two hundred and fifty-five patients were included in the study, including 85 patients with SCI. Average risk screening was a more common colonoscopy indication in patients with SCI vs. the control population (24 vs. 13% p = 0.03). There was no difference in adequacy of bowel preparation (87 vs. 85%, p = 0.73) or adenoma detection rate (55 vs. 51%, p = 0.59) when comparing patients with SCI with the control population. No difference in polyp histopathology was detected (p = 0.748). Our study demonstrated that an extended bowel preparation for patients with SCI produces similar bowel preparation results and diagnostic yield when compared to patients without SCI undergoing colonoscopy.

  19. Educational Colonoscopy Video Enhances Bowel Preparation Quality and Comprehension in an Inner City Population.

    PubMed

    Pillai, Ajish; Menon, Radha; Oustecky, David; Ahmad, Asyia

    2017-07-24

    Quality of bowel preparation and patient knowledge remains a major barrier for completing colorectal cancer screening. Few studies have tested unique ways to impact patient understanding centering on interactive computer programs, pictures, and brochures. Two studies explored instructional videos but focused on patient compliance and anxiety as endpoints. Furthermore, excessive video length and content may limit their impact on a broad patient population. No study so far has studied a video's impact on preparation quality and patient understanding of the colonoscopy procedure. We conducted a single blinded prospective study of inner city patients presenting for a first time screening colonoscopy. During their initial visit patients were randomized to watch an instructional colonoscopy video or a video discussing gastroesophageal reflux disease (GERD). All patients watched a 6 minutes long video with the same spokesperson, completed a demographic questionnaire (Supplemental Digital Content 1, http://links.lww.com/JCG/A352) and were enrolled only if screened within 30 days of their visit. On the day of the colonoscopy, patients completed a 14 question quiz of their knowledge. Blinded endoscopist graded patient preparations based on the Ottawa scale. All authors had access to the study data and reviewed and approved the final manuscript. Among the 104 subjects enrolled in the study, 56 were in the colonoscopy video group, 48 were in GERD video group, and 12 were excluded. Overall, 48% were male and 52% female; 90% of patients had less than a high school education, 76% were African American, and 67% used a 4 L split-dose preparation. There were no differences between either video group with regard to any of the above categories. Comparisons between the 2 groups revealed that the colonoscopy video group had significantly better Ottawa bowel preparation score (4.77 vs. 6.85; P=0.01) than the GERD video group. The colonoscopy video group also had less-inadequate repeat

  20. Mechanical bowel preparation and oral antibiotic prophylaxis in colorectal surgery: Analysis of evidence and narrative review.

    PubMed

    Badia, Josep M; Arroyo-García, Nares

    2018-05-14

    The role of oral antibiotic prophylaxis and mechanical bowel preparation in colorectal surgery remains controversial. The lack of efficacy of mechanical preparation to improve infection rates, its adverse effects, and multimodal rehabilitation programs have led to a decline in its use. This review aims to evaluate current evidence on antegrade colonic cleansing combined with oral antibiotics for the prevention of surgical site infections. In experimental studies, oral antibiotics decrease the bacterial inoculum, both in the bowel lumen and surgical field. Clinical studies have shown a reduction in infection rates when oral antibiotic prophylaxis is combined with mechanical preparation. Oral antibiotics alone seem to be effective in reducing infection in observational studies, but their effect is inferior to the combined preparation. In conclusion, the combination of oral antibiotics and mechanical preparation should be considered the gold standard for the prophylaxis of postoperative infections in colorectal surgery. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Preparation and Properties of Nanoparticles of Calcium Phosphates With Various Ca/P Ratios.

    PubMed

    Sun, Limin; Chow, Laurence C; Frukhtbeyn, Stanislav A; Bonevich, John E

    2010-01-01

    This study aimed at preparing and studying the properties of nanoparticles of calcium phosphate (nCaP) with Ca/P ratios ranging from 1.0 to 1.67 using a spray-drying technique. Micro-structural analyses suggested that the nCaPs with Ca/P ratios of 1.67 to 1.33 were nano-sized amorphous calcium phosphate (ACP) containing varying amounts of acid phosphate and carbonate. The nCaP with Ca/P ratio of 1 contained only nano-sized low crystalline dicalcium phosphate (DCP). BET measurements of the nCaPs showed specific surface areas of (12 ± 2 to 50 ± 1) m(2)/g, corresponding to estimated equivalent spherical diameters of (38 to 172) nm. However, dynamic light scattering measurements revealed much larger particles of (380 ± 49 to 768 ± 111) nm, owing to agglomeration of the smaller primary nano particles as revealed by Scanning Electron Microscopy (SEM). Thermodynamic solubility measurements showed that the nCaPs with Ca/P ratio of 1.33 - 1.67 all have similar solubility behavior. The materials were more soluble than the crystalline hydroxyapatite (HA) at pH greater than about 4.7, and more soluble than β-tricalcium phosphate (β-TCP), octacalcium phosphate (OCP) and DCP at pH above 5.5. Their solubility approached that of α-tricalcium phosphate (α-TCP) at about pH 7. These nCaPs, which cannot be readily prepared by other currently available methods for nanoparticle preparation, have potential biomedical applications.

  2. Preparation and Properties of Nanoparticles of Calcium Phosphates With Various Ca/P Ratios

    PubMed Central

    Sun, Limin; Chow, Laurence C.; Frukhtbeyn, Stanislav A.; Bonevich, John E.

    2010-01-01

    This study aimed at preparing and studying the properties of nanoparticles of calcium phosphate (nCaP) with Ca/P ratios ranging from 1.0 to 1.67 using a spray-drying technique. Micro-structural analyses suggested that the nCaPs with Ca/P ratios of 1.67 to 1.33 were nano-sized amorphous calcium phosphate (ACP) containing varying amounts of acid phosphate and carbonate. The nCaP with Ca/P ratio of 1 contained only nano-sized low crystalline dicalcium phosphate (DCP). BET measurements of the nCaPs showed specific surface areas of (12 ± 2 to 50 ± 1) m2/g, corresponding to estimated equivalent spherical diameters of (38 to 172) nm. However, dynamic light scattering measurements revealed much larger particles of (380 ± 49 to 768 ± 111) nm, owing to agglomeration of the smaller primary nano particles as revealed by Scanning Electron Microscopy (SEM). Thermodynamic solubility measurements showed that the nCaPs with Ca/P ratio of 1.33 – 1.67 all have similar solubility behavior. The materials were more soluble than the crystalline hydroxyapatite (HA) at pH greater than about 4.7, and more soluble than β-tricalcium phosphate (β-TCP), octacalcium phosphate (OCP) and DCP at pH above 5.5. Their solubility approached that of α-tricalcium phosphate (α-TCP) at about pH 7. These nCaPs, which cannot be readily prepared by other currently available methods for nanoparticle preparation, have potential biomedical applications. PMID:21037948

  3. Systematic review and meta-analysis of colon cleansing preparations in patients with inflammatory bowel disease

    PubMed Central

    Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N

    2017-01-01

    AIM To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. METHODS Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. RESULTS Out of 439 citations, 4 trials fulfilled our inclusion criteria (n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). CONCLUSION In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population. PMID:28932092

  4. Systematic review and meta-analysis of colon cleansing preparations in patients with inflammatory bowel disease.

    PubMed

    Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N

    2017-08-28

    To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. Out of 439 citations, 4 trials fulfilled our inclusion criteria ( n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population.

  5. Objective and Subjective Intra-patient Comparison of Iohexol versus Diatrizoate for Bowel Preparation Quality at CT Colonography

    PubMed Central

    Johnson, Brandon; Hinshaw, J. Louis; Robbins, Jessica B.; Pickhardt, Perry J.

    2017-01-01

    Objective To objectively and subjectively compare nonionic iohexol and ionic diatrizoate iodinated oral contrast as part of a cathartic bowel regimen within the same CT colonography (CTC) cohort, with otherwise identical preparations. Materials and Methods In our IRB-approved retrospective study, 46 asymptomatic adults (mean age, 59.4 years; 26M/20F) returning for follow-up CTC over a 9-month interval underwent the same bowel preparation with the exception of 75 ml iohexol 350 (Omnipaque) in place of 60 ml diatrizoate (Gastrografin). All other preparation components (bisacodyl, magnesium citrate, and 2% barium) remained constant. Objective volumetric analysis of residual colonic fluid volume and fluid attenuation was performed. Additionally, two radiologists experienced with CTC, blinded to the specific bowel preparation, scored each of 6 colonic segments for adherent residual solid stool using a previously validated 4-point scale (0 for no stool; 1–3 for increasing residual stool). Paired t-test was used for comparison of the cohorts. Results No clear clinically-meaningful difference was found between the two preparations on overall objective or subjective evaluation. Mean (±SD) residual fluid volume was 173±126 ml with the iohexol preparation and 130±79 ml with the diatrizoate prep (p=0.02). Mean total colonic stool score was 2.5 (0.42/segment) with iohexol and 2.3 (0.38/segment) with diatrizoate (p=0.69). Mean (±SD) fluid attenuation was higher with iohexol (849±270HU) compared with diatrizoate (732±168HU) (p=0.03). Conclusions Based on this direct intra-patient comparison, we found that oral iohexol is a suitable alternative to diatrizoate for fluid tagging as part of a cathartic bowel preparation at CTC. Because this nonionic tagging agent is more palatable, less expensive, and likely safer than ionic diatrizoate, our CTC program now utilizes iohexol as the standard recommended regimen. PMID:27010251

  6. Sphingosine-1-Phosphate Metabolism and Its Role in the Development of Inflammatory Bowel Disease

    PubMed Central

    Wollny, Tomasz; Wątek, Marzena; Durnaś, Bonita; Niemirowicz, Katarzyna; Piktel, Ewelina; Żendzian-Piotrowska, Małgorzata; Góźdź, Stanisław; Bucki, Robert

    2017-01-01

    Beyond their role as structural molecules, sphingolipids are involved in many important cellular processes including cell proliferation, apoptosis, inflammation, and migration. Altered sphingolipid metabolism is observed in many pathological conditions including gastrointestinal diseases. Inflammatory bowel disease (IBD) represents a state of complex, unpredictable, and destructive inflammation of unknown origin within the gastrointestinal tract. The mechanisms explaining the pathophysiology of IBD involve signal transduction pathways regulating gastro-intestinal system’s immunity. Progressive intestinal tissue destruction observed in chronic inflammation may be associated with an increased risk of colon cancer. Sphingosine-1-phosphate (S1P), a sphingolipid metabolite, functions as a cofactor in inflammatory signaling and becomes a target in the treatment of IBD, which might prevent its conversion to cancer. This paper summarizes new findings indicating the impact of (S1P) on IBD development and IBD-associated carcinogenesis. PMID:28362332

  7. Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy

    PubMed Central

    Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele

    2013-01-01

    AIM: To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. METHODS: This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. Interventions: BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. RESULTS: Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). CONCLUSION: BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy. PMID:24023492

  8. Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy.

    PubMed

    Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele

    2013-09-07

    To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy.

  9. Quality and stability of extemporaneous pyridoxal phosphate preparations used in the treatment of paediatric epilepsy.

    PubMed

    Mohamed-Ahmed, Abeer H A; Wilson, Matthew P; Albuera, Maedelyn; Chen, Ting; Mills, Philippa B; Footitt, Emma J; Clayton, Peter T; Tuleu, Catherine

    2017-04-01

    To assess the pyridoxal 5'-phosphate (PLP) content and stability of extemporaneous PLP liquids prepared from dietary supplements used for the treatment of vitamin B 6 -dependent epilepsy. Pyridoxal 5'-phosphate liquids were prepared in accordance with the guidelines given to patients from marketed 50 mg PLP dietary capsules and tablets. The PLP content and its stability were evaluated under conditions resembling the clinical setting using reverse phase HPLC and mass spectrometry. Pyridoxal 5'-phosphate content in most of the extemporaneously prepared liquids from dietary supplements was found to be different from the expected amount (~16-60 mg). Most of these PLP extemporaneous liquids were stable at room temperature (protected from light) after 24 h but unstable after 4 h when exposed to light. A key photodegradation product of PLP in water was confirmed as 4-pyridoxic acid 5'-phosphate (PAP). Pyridoxal 5'-phosphate tablets from Solgar ® were found to be the most reliable product for the preparation of extemporaneous PLP liquids. This work highlighted the difference between the marketed PLP dietary supplements quality and the importance of proper storage of aqueous PLP. There is a need to develop pharmaceutical forms of PLP that ensure dose accuracy and avoid potentially unsafe impurities with the aim of enhancing safety and compliance. © 2017 Royal Pharmaceutical Society.

  10. Double-blind prospective randomized study comparing polyethylene glycol to lactulose for bowel preparation in colonoscopy.

    PubMed

    Menacho, Aline Moraes; Reimann, Adriano; Hirata, Lie Mara; Ganzerella, Caroline; Ivano, Flavio Heuta; Sugisawa, Ricardo

    2014-01-01

    Colonoscopy is the most frequent exam used to evaluate colonic mucosa, allowing the diagnosis and treatment of many diseases. The appropriate bowel preparation is indispensable for the realization of colonoscopy. Therefore, it is necessary the use of laxative medications, preferentially by oral administration. To compare two medications used in bowel preparation in adult patients going to ambulatory colonoscopy and to analyze the patients' profile. A double-blind prospective study with 200 patients, randomized in two groups: one that received polyethilene glycol and another that received lactulose. The patients answered to questionnaires to data compilation, as tolerance, symptoms and complications related to preparation. Besides, it was also evaluated the prepare efficacy related to the presence of fecal residue. Intestinal habit alterations and abdominal pain were the main reasons to realize the exams and hypertension was the most prevalent comorbidity. Ten percent of the ones who received lactulose didn't get to finish the preparation and 50% considered the taste "bad, but tolerable". The most common subjective symptom after the medication was nausea, especially after lactulose. During the exam, most of the patients who used lactulose had a "light discomfort" and the ones who used polyethilene glycol considered the discomfort as "tolerable". The quality of the preparation was good in 75%, undependable of the medication that was used. Polyethilene glycol was more tolerable when compared to lactulose, without difference on the quality of the preparation.

  11. DOUBLE-BLIND PROSPECTIVE RANDOMIZED STUDY COMPARING POLYETHYLENE GLYCOL TO LACTULOSE FOR BOWEL PREPARATION IN COLONOSCOPY

    PubMed Central

    MENACHO, Aline Moraes; REIMANN, Adriano; HIRATA, Lie Mara; GANZERELLA, Caroline; IVANO, Flavio Heuta; SUGISAWA, Ricardo

    2014-01-01

    Background Colonoscopy is the most frequent exam used to evaluate colonic mucosa, allowing the diagnosis and treatment of many diseases. The appropriate bowel preparation is indispensable for the realization of colonoscopy. Therefore, it is necessary the use of laxative medications, preferentially by oral administration. Aim To compare two medications used in bowel preparation in adult patients going to ambulatory colonoscopy and to analyze the patients' profile. Methods A double-blind prospective study with 200 patients, randomized in two groups: one that received polyethilene glycol and another that received lactulose. The patients answered to questionnaires to data compilation, as tolerance, symptoms and complications related to preparation. Besides, it was also evaluated the prepare efficacy related to the presence of fecal residue. Results Intestinal habit alterations and abdominal pain were the main reasons to realize the exams and hypertension was the most prevalent comorbidity. Ten percent of the ones who received lactulose didn't get to finish the preparation and 50% considered the taste "bad, but tolerable". The most common subjective symptom after the medication was nausea, especially after lactulose. During the exam, most of the patients who used lactulose had a "light discomfort" and the ones who used polyethilene glycol considered the discomfort as "tolerable". The quality of the preparation was good in 75%, undependable of the medication that was used. Conclusion Polyethilene glycol was more tolerable when compared to lactulose, without difference on the quality of the preparation. PMID:24676290

  12. Preparation of titanium phosphates with additives in hydrothermal process and their powder properties for cosmetics.

    PubMed

    Onoda, Hiroaki; Yamaguchi, Taisuke

    2013-04-01

    In this study, titanium phosphates were prepared from titanium chloride and phosphoric acid, sodium pyrophosphate and sodium triphosphate solutions with water retention compounds in hydrothermal process as a novel white pigment for cosmetics. Their chemical composition, powder properties, photo catalytic activity, water retention and smoothness were studied. The addition of glycerin in the preparation from sodium pyrophosphate has the useful method to obtain homogenized spherical particles of titanium phosphate pigments for the cosmetics. These titanium phosphates had less photo catalytic activity to protect the sebum on the skin. © 2012 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  13. Preparation and characterization of calcium phosphate ceramics and composites as bone substitutes

    NASA Astrophysics Data System (ADS)

    Zhang, Xing

    Marine CaCO3 skeletons have tailored architectures created by nature, which give them structural support and other functions. For example, seashells have dense lamellar structures, while coral, cuttlebone and sea urchin spines have interconnected porous structures. In our experiments, seashells, coral and cuttlebone were hydrothermally converted to hydroxyapatite (HAP), and sea urchin spines were converted to Mg-substituted tricalcium phosphate (beta-TCMP), while maintaining their original structures. Partially converted shell samples have mechanical strength, which is close to that of compact human bone. After implantation of converted shell and spine samples in rat femoral defects for 6 weeks, there was newly formed bone growth up to and around the implants. Some new bone was found to migrate through the pores of converted spine samples and grow inward. These results show good bioactivity and osteoconductivity of the implants, indicating the converted shell and spine samples can be used as bone defect fillers. Calcium phosphate powders were prepared through different synthesis methods. Micro-size HAP rods were synthesized by hydrothermal method through a nucleation-growth mechanism. On the other hand, HAP particles, which have good crystallinity, were prepared by wet precipitation with further hydrothermal treatment. beta-TCP or beta-TCMP powders were prepared by a two-step process: wet precipitation of apatitic tricalcium phosphate ('precursor') and calcination of the precursor at 800°C for 3 hours. beta-TCMP or beta-TCP powders were also prepared by solid-state reactions from CaHPO4 and CaCO 3 with/without MgO. Biphasic calcium phosphate, which is mixture of HAP and beta-TCP, can be prepared though mechanical mixing of HAP and beta-TCP powders synthesized as above. Dense beta-TCP and beta-TCMP ceramics can be produced by pressing green bodies at 100MPa and further sintering above 1100°C for 2 hours. beta-TCMP ceramics ˜99.4% relative dense were prepared by

  14. Effect of preadmission bowel preparation on outcomes of elective colorectal procedures in young children.

    PubMed

    Ares, Guillermo J; Helenowski, Irene; Hunter, Catherine J; Madonna, Marybeth; Reynolds, Marleta; Lautz, Timothy

    2018-04-01

    The utility of mechanical bowel preparation (MBP) to minimize infectious complications in elective colorectal surgery is contentious. Though data is scarce in children, adult studies suggest a benefit to MBP when administered with oral antibiotics (OAB). After IRB approval, the Pediatric Health Information System (PHIS) was queried for young children undergoing elective colon surgery from 2011 to 2014. Patients were divided into: no bowel preparation (Group 1), MBP (Group 2), and MBP plus OAB (Group 3). Statistical significance was determined using univariate and multivariate analysis with GEE models accounting for clustering by hospital. One thousand five hundred eighty-one patients met study criteria: 63.7% in Group 1, 27.1% in Group 2, and 9.2% in Group 3. Surgical complication rate was higher in Group 1 (23.3%) compared to Groups 2 and 3 (14.2% and 15.5%; P<0.001). However, median length of stay was shorter in Group 1 (4, IQR 4days) compared to Group 2 (5, IQR 3) and Group 3 (6, IQR 3) (P<0.001). 30-day readmission rates were similar. In multivariate analysis compared to patients in Group 1, the odds of surgical complications were 0.72 (95% CI 0.40-1.29, P=0.28) with MBP alone (Group 2), 1.79 (95% CI 1.28-2.52, P=0.0008) with MBP+OAB (Group 3), and 1.13 (95% CI 0.81-1.58, P=0.46) for the aggregate Group 2 plus 3. Utilization of bowel preparation in children is variable across children's hospitals nationally, and the benefit is unclear. Given the discrepancy with adult literature, a three-armed pediatric-specific randomized controlled trial is warranted. Level III treatment study - retrospective comparative study. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Large-bowel surgery, 1979: self-assessment.

    PubMed Central

    Matheson, N A; Valerio, D

    1980-01-01

    Evidence of wide variability in the immediate results of large-bowel surgery stimulated self-assessment during 1979. The hazards of large-bowel surgery can usually be avoided by good bowel preparation, sound anastomotic technique, primary resection in large bowel emergencies, avoidance of anastomosis when hazardous, and antibiotic lavage for extant or potential peritoneal and wound contamination. PMID:7427416

  16. Effectiveness of Sodium Picosulfate/Magnesium Citrate (PICO) for Colonoscopy Preparation

    PubMed Central

    Suh, Wu Seok; Jeong, Jin Sik; Kim, Dong Sik; Kim, Sang Woo; Kwak, Dong Min; Hwang, Jong Seong; Kim, Hyun Jin; Park, Man Woo; Shim, Min Chul; Koo, Ja-Il; Kim, Jae Hwang; Shon, Dae Ho

    2014-01-01

    Purpose Bowel preparation with sodium phosphate was recently prohibited by the U.S. Food and Drug Administration. Polyethylene glycol (PEG) is safe and effective; however, it is difficult to drink. To identify an easy bowel preparation method for colonoscopy, we evaluated three different bowel preparation regimens regarding their efficacy and patient satisfaction. Methods In this randomized, comparative study, 892 patients who visited a secondary referral hospital for a colonoscopy between November 2012 and February 2013 were enrolled. Three regimens were evaluated: three packets of sodium picosulfate/magnesium citrate (PICO, group A), two packets of PICO with 1 L of PEG (PICO + PEG 1 L, group B), and two packets of PICO with 2 L of PEG (PICO + PEG 2 L, group C). A questionnaire survey regarding the patients' preference for the bowel preparation regimen and satisfaction was conducted before the colonoscopies. The quality of bowel cleansing was scored by the colonoscopists who used the Aronchick scoring scale and the Ottawa scale. Results The patients' satisfaction rate regarding the regimens were 72% in group A, 64% in group B, and 45.9% in group C. Nausea and abdominal bloating caused by the regimens were more frequent in group C than in group A or group B (P < 0.01). Group C showed the lowest preference rate compared to the other groups (P < 0.01). Group C showed better right colon cleansing efficacy than group A or group B. Conclusion Group A exhibited a better result than group B or group C in patient satisfaction and preference. In the cleansing quality, no difference was noted between groups A and C. PMID:25360429

  17. Polyethylene glycol plus ascorbic acid is as effective as sodium picosulfate with magnesium citrate for bowel preparation: A randomized trial.

    PubMed

    Choi, Hyun-Seok; Chung, Jun-Won; Lee, Ji Won; Lim, Min Young; Park, Dong Kyun; Kim, Yoon Jae; Kwon, Kwang Ahn; Kim, Jung Ho

    2016-04-01

    This study was aimed to evaluate the efficacy and safety of two low-volume agents, polyethylene glycol (PEG)-3350 plus ascorbic acid (PEG + Asc) and sodium picosulfate with magnesium citrate (SPMC), for bowel preparation. We performed a prospective, endoscopist-blinded, single-center, randomized controlled trial comparing PEG + Asc with SPMC to evaluate the bowel cleansing efficacy of the two regimens using the modified Ottawa bowel preparation scale (OBPS) and the Aronchick scale. Patients' taste and overall tolerance were assessed with a questionnaire. In total, 200 patients were randomized to receive either PEG + Asc (n = 98) or SPMC (n = 102). Both treatments were similarly efficacious in bowel cleansing, based on the modified OBSP (PEG + Asc 4.01 ± 2.29 vs SPMC 3.86 ± 2.47, P = 0.62) and Aronchick scale (PEG + Asc 1.96 ± 0.70 vs SPMC 1.89 ± 0.70, P = 0.42). Patient-reported taste and tolerance of each regimen, as reported by the questionnaire, were significantly greater in the PEG + Asc group than in the SPMC group (P = 0.01). In terms of adverse events, dizziness was more frequently observed in the PEG + Asc group (P = 0.03), whereas nausea was more common in the SPMC group (P = 0.02). PEG + Asc and SPMC show similar efficacy for bowel preparation. However, patient's overall tolerance is higher in the PEG + Asc group. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  18. A prospective randomized trial on the use of Coca-Cola Zero(®) vs water for polyethylene glycol bowel preparation before colonoscopy.

    PubMed

    Seow-En, I; Seow-Choen, F

    2016-07-01

    The study aimed to determine whether Coca-Cola (Coke) Zero is a safe and effective solvent for polyethylene glycol (PEG). Between December 2013 and April 2014, 209 healthy adults (115 men, 95 women) scheduled for elective colonoscopy were randomized to use either Coke Zero (n = 100) or drinking water (n = 109) with PEG as bowel preparation. Each patient received two sachets of PEG to dissolve in 2 l of solvent, to be completed 6 h before colonoscopy. Serum electrolytes were measured before and after preparation. Bowel cleanliness and colonoscopy findings were recorded. Palatability of solution, adverse effects, time taken to complete and willingness to repeat the preparation were documented via questionnaire. Mean palatability scores in the Coke Zero group were significantly better compared with the control group (2.31 ± 0.61 vs 2.51 ± 0.63, P = 0.019), with a higher proportion willing to use the same preparation again (55% vs 43%). The mean time taken to complete the PEG + Coke Zero solution was significantly faster (74 ± 29 min vs 86 ± 31 min, P = 0.0035). The quality of bowel cleansing was also significantly better in the Coke Zero group (P = 0.0297). There was no difference in the frequency of adverse events (P = 0.759) or the polyp detection rate (32% vs 31.2%). Consumption of either preparation did not significantly affect electrolyte levels or hydration status. Coke Zero is a useful alternative solvent for PEG. It is well tolerated, more palatable, leads to quicker consumption of the bowel preparation and results in better quality cleansing. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.

  19. Essential elucidation for preparation of supported nickel phosphide upon nickel phosphate precursor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xuguang, E-mail: liuxuguang@qust.edu.cn; Xu, Lei; Zhang, Baoquan

    2014-04-01

    Preparation of supported nickel phosphide (Ni{sub 2}P) depends on nickel phosphate precursor, generally related to its chemical composition and supports. Study of this dependence is essential and meaningful for the preparation of supported Ni{sub 2}P with excellent catalytic activity. The chemical nature of nickel phosphate precursor is revealed by Raman and UV–vis spectra. It is found that initial P/Ni mole ratio ≥0.8 prohibits the Ni-O-Ni bridge bonding (i.e., nickel oxide). This chemical bonding will not result in Ni{sub 2}P structure, verified by XRD characterization results. The alumina (namely, γ-Al{sub 2}O{sub 3}, θ-Al{sub 2}O{sub 3}, or α-Al{sub 2}O{sub 3}) with distinctmore » physiochemical properties also results in diverse chemical nature of nickel phosphate, and then different nickel phosphides. The influence of alumina support on producing Ni{sub 2}P was explained by the theory of surface energy heterogeneity, calculated by the NLDFT method based on N{sub 2}-sorption isotherm. The uniform surface energy of α-Al{sub 2}O{sub 3} results only in the nickel phosphosate precursor and thus the Ni{sub 2}P phase. - Graphical abstract: Surface energy heterogeneity in alumina (namely α-Al{sub 2}O{sub 3}, θ-Al{sub 2}O{sub 3}, and γ-Al{sub 2}O{sub 3}) supported multi-oxidic precursors with different reducibilities and thus diverse nickel phosphides (i.e., Ni{sub 3}P, Ni{sub 12}P{sub 5}, Ni{sub 2}P). - Highlights: • Preparing pure Ni{sub 2}P. • Elucidating nickel phosphate precursor. • Associating with surface energy.« less

  20. Preoperative bowel preparation with meglumine and sodium diatrizoate (Gastrografin): a prospective randomised comparison.

    PubMed

    Koussidis, G A; Koussidis, A

    2001-12-01

    To test the use of meglumine and sodium diatrizoate (Gastrografin) as an agent for preoperative mechanical bowel preparation. Prospective randomised comparison. County general hospital, Greece. 58 patients listed for elective colorectal operations were randomly divided into 2 groups. The first (n = 30) was given Gastrografin 200 ml orally for 2 consecutive days before operation, and the second (n = 28) was given Ringer's solution through a nasogastric tube. Tolerability, acceptability, quality of cleansing, and complications. There were no disturbances in electrolyte concentrations, and other laboratory variables also remained unchanged. Two patients treated with Ringer's solution had appreciable increases in arterial blood pressure, but there were no significant overall changes. About half the patients given Ringer's felt nauseated and a third vomited. Such symptoms were uncommon in patients treated with Gastrografin (p < 0.01). 28/30 and 26/28 (93%) had a clean colonic lumen at operation, whereas in the reminder the lumen was evaluated as containing "slight residue". There were no operation-related complications. Gastrografin can be used successfully as an agent for mechanical bowel preparation before elective colorectal surgery, as it gives equally good cleansing results compared with the established method of whole gut irrigation. It also seems to be better tolerated and accepted by patients.

  1. Comparative Study of Three Regimens of Bowel Preparation Before Transabdominal Ultrasonography of the Colon.

    PubMed

    Fan, Xiu-Ping; Zhu, Qiang; Zhou, Ya-Jing; Ma, Teng; Xia, Chun-Xia; Huang, Hui-Lian

    2016-09-01

    The objective of the study was to compare the efficacy of three bowel preparation regimens for transabdominal colon ultrasonography. A total of 192 consecutive patients were given one of three regimens (senna, magnesium sulfate or polyethylene glycol electrolyte powder) before ultrasonographic examinations. The cleaning grade (I = emptying; II = filled or filled + empty; III = I or II with some retention; and IV = retention [grades I and II were termed "qualified"]) and cleaning range (A = all seven colon sections were qualified; B = four to six sections were qualified; C = three or less sections were qualified) were evaluated retrospectively. Senna was found more effective than polyethylene glycol in terms of cleaning grade (p < 0.001), qualified rate (p < 0.001) and cleaning range (p = 0.003). Senna was better than magnesium sulfate in cleaning grade (p < 0.001). Our results suggest that senna seems to be the preferred regimen for bowel preparation before transabdominal colonic ultrasonography. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. National CT Colonography Trial (ACRIN 6664): Comparison of Three Full-Laxative Bowel Preparations in More Than 2500 Average-Risk Patients

    PubMed Central

    Hara, Amy K.; Kuo, Mark D.; Blevins, Meridith; Chen, Mei-Hsiu; Yee, Judy; Dachman, Abraham; Menias, Christine O.; Siewert, Betina; Cheema, Jugesh I.; Obregon, Richard G.; Fidler, Jeff L.; Zimmerman, Peter; Horton, Karen M.; Coakley, Kevin; Iyer, Revathy B.; Halvorsen, Robert A.; Casola, Giovanna; Johnson, C. Daniel

    2011-01-01

    OBJECTIVE The purpose of our study was to compare the effect of three different full-laxative bowel preparations on patient compliance, residual stool and fluid, reader confidence, and polyp detection at CT colonography (CTC). SUBJECTS AND METHODS A total of 2531 patients underwent CTC followed by colonoscopy for the American College of Radiology Imaging Network (ACRIN) National CTC Trial. Of this total, 2525 patients used one of three bowel preparations with bisacodyl tablets and stool and fluid tagging: 4 L of polyethylene glycol (PEG); 90 mL of phosphosoda; or 300 mL of magnesium citrate. Patients reported percent compliance with the bowel preparation and radiologists graded each CTC examination for the amount of residual fluid and stool on a scale from 1 (none) to 4 (nondiagnostic). Reader confidence for true-positive findings was reported on a 5-point scale: 1 (low) to 5 (high). Sensitivity and specificity for detecting polyps ≥ 6 mm and ≥ 1 cm compared with colonoscopy were calculated for each preparation. RESULTS The most commonly prescribed preparation was phosphosoda (n = 1403) followed by PEG (n = 1020) and magnesium citrate (n = 102). Phosphosoda had the highest patient compliance (p = 0.01), least residual stool (p < 0.001), and highest reader confidence versus PEG for examinations with polyps (p = 0.06). Magnesium citrate had significantly more residual fluid compared with PEG and phosphosoda (p = 0.006). The sensitivity and specificity for detecting colon polyps ≥ 6 mm and ≥ 1 cm did not differ significantly between preparations. CONCLUSION Polyp detection was comparable for all three preparations, although phosphosoda had significantly higher patient compliance and the least residual stool. PMID:21512073

  3. Preparation and testing of a tetra-amine copper(II) chitosan bead system for enhanced phosphate remediation.

    PubMed

    Kumar, Ilango Aswin; Viswanathan, Natrayasamy

    2018-03-01

    A tetra-amine copper(II) chitosan bead system (TAC@CS composite beads) was developed by grafting tetra-amine copper(II) (TAC) with chitosan (CS) and utilized for phosphate removal. The prepared TAC@CS composite beads possess enhanced phosphate sorption capacity (SC) of 41.42 ± 0.071 mg/g than copper grafted chitosan (Cu@CS) composite, TAC and chitosan which were found to be 37.01 ± 0.803, 33.20 ± 0.650 and 7.24 ± 0.059 mg/g respectively. In batch mode, various adsorption influencing parameters like contact time, initial phosphate concentration, solution pH, co-anions and temperature were optimized for maximum phosphate sorption. The prepared adsorbents were characterized by FTIR, XRD, UV-Visible, SEM and EDAX analysis. The adsorption isotherms and thermodynamic parameters of the adsorbent were studied. The feasible phosphate uptake mechanism of TAC@CS biocomposite beads was reported. The reusability studies of TAC@CS composite beads were carried out using NaOH as elutant. The suitability of TAC@CS composite beads at field conditions was tested with phosphate contaminated field water samples collected from nearby areas of Dindigul district. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Glasses of three alkyl phosphates show a range of kinetic stabilities when prepared by physical vapor deposition

    NASA Astrophysics Data System (ADS)

    Beasley, M. S.; Tylinski, M.; Chua, Y. Z.; Schick, C.; Ediger, M. D.

    2018-05-01

    In situ AC nanocalorimetry was used to characterize vapor-deposited glasses of three phosphates with increasing lengths of alkyl side chains: trimethyl phosphate, triethyl phosphate, and tributyl phosphate. The as-deposited glasses were assessed in terms of their reversing heat capacity, onset temperature, and isothermal transformation time. Glasses with a range of kinetic stabilities were prepared, including kinetically stable glasses, as indicated by high onset temperatures and long transformation times. Trimethyl phosphate forms kinetically stable glasses, similar to many other organic molecules, while triethyl phosphate and tributyl phosphate do not. Triethyl phosphate and tributyl phosphate present the first examples of non-hydrogen bonding systems that are unable to form stable glasses via vapor deposition at 0.2 nm/s. Based on experiments utilizing different deposition rates, we conclude that triethyl phosphate and tributyl phosphate lack the surface mobility required for stable glass formation. This may be related to their high enthalpies of vaporization and the internal structure of the liquid state.

  5. Kidney injury after sodium phosphate solution beyond the acute renal failure.

    PubMed

    Fernández-Juárez, Gema; Parejo, Leticia; Villacorta, Javier; Tato, Ana; Cazar, Ramiro; Guerrero, Carmen; Marin, Isabel Martinez; Ocaña, Javier; Mendez-Abreu, Angel; López, Katia; Gruss, Enrique; Gallego, Eduardo

    2016-01-01

    Screening colonoscopy with polipectomy reduces colonorectal cancer incidence and mortality. An adequate bowel cleansing is one of the keys to achieving best results with this technique. Oral sodium phosphate solution (OSP) had a widespread use in the 90s decade. Its efficacy was similar to polyethylene glycol (PEG) solution, but with less cost and convenient administration. Series of patients with acute renal failure due to OSP use have been reported. However, large cohorts of patients found no difference in the incidence of renal damage between these two solutions. From 2006 to 2009 we identified twelve cases of phosphate nephropathy after colonoscopy prepared with OSP. All patients were followed up to six months. All patients had received just a single dose. We analyzed 12 cases with phosphate nephropathy; three patients debuted with AKI and nine patients had chronic renal injury. Four cases were confirmed with renal biopsy. One patient with AKI needed hemodialysis at diagnosis without subsequent recovery. Two patients (both with chronic damage) fully recovered their previous renal function. The remaining patients (nine) had an average loss of estimated glomerular filtration rate of 24ml/min/1.73m(2). The use of OSP can lead to both acute and chronic renal damage. However, chronic injury was the most common pattern. Both forms of presentation imply a significant and irreversible loss of renal function. Further studies analyzing renal damage secondary to bowel cleaning should consider these two different patterns of injury. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Budget-impact model for colonoscopy cost calculation and comparison between 2 litre PEG+ASC and sodium picosulphate with magnesium citrate or sodium phosphate oral bowel cleansing agents.

    PubMed

    Gruss, H-J; Cockett, A; Leicester, R J

    2012-01-01

    With the availability of several bowel cleansing agents, physicians and hospitals performing colonoscopies will often base their choice of cleansing agent purely on acquisition cost. Therefore, an easy to use budget impact model has been developed and established as a tool to compare total colon preparation costs between different established bowel cleansing agents. The model was programmed in Excel and designed as a questionnaire evaluating information on treatment costs for a range of established bowel cleansing products. The sum of costs is based on National Health Service reference costs for bowel cleansing products. Estimations are made for savings achievable when using a 2-litre polyethylene glycol with ascorbate components solution (PEG+ASC) in place of other bowel cleansing solutions. Test data were entered into the model to confirm validity and sensitivity. The model was then applied to a set of audit cost data from a major hospital colonoscopy unit in the UK. Descriptive analysis of the test data showed that the main cost drivers in the colonoscopy process are the procedure costs and costs for bed days rather than drug acquisition costs, irrespective of the cleansing agent. Audit data from a colonoscopy unit in the UK confirmed the finding with a saving of £107,000 per year in favour of PEG+ASC when compared to sodium picosulphate with magnesium citrate solution (NaPic+MgCit). For every patient group the model calculated overall cost savings. This was irrespective of the higher drug expenditure associated with the use of PEG+ASC for bowel preparation. Savings were mainly realized through reduced costs for repeat colonoscopy procedures and associated costs, such as inpatient length of stay. The budget impact model demonstrated that the primary cost driver was the procedure cost for colonoscopy. Savings can be realized through the use of PEG+ASC despite higher drug acquisition costs relative to the comparator products. From a global hospital funding

  7. Removal of phosphate using copper-loaded polymeric ligand exchanger prepared by radiation grafting of polypropylene/polyethylene (PP/PE) nonwoven fabric

    NASA Astrophysics Data System (ADS)

    Barsbay, Murat; Kavaklı, Pınar Akkaş; Güven, Olgun

    2010-03-01

    A novel polymeric ligand exchanger (PLE) was prepared for the removal of phosphate ions from water. 2,2'-dipyridylamine (DPA), a bidentate ligand forming compound with high coordination capacity with a variety of metal ions was bound to glycidyl methacrylate (GMA) grafted polypropylene/polyethylene (PP/PE) nonwoven fabric synthesized by radiation-induced grafting technique. DPA attachment on epoxy ring of GMA units was tested in different solvents, i.e. methanol, ethanol, dioxane and dimethylsulfoxide (DMSO). The highest amount of modification was achieved in dioxane. In order to prepare the corresponding PLE for the removal of phosphate, DPA-immobilized fabric was loaded with Cu(II) ions. Phosphate adsorption experiments were performed in batch mode at different pH (5-9) and phosphate concentrations. The fabric was found to be effective for the removal of phosphate ions. At every stage of preparation and use, the nonwoven fabric was characterized by thermal (i.e. DSC and TGA) and spectroscopic (FTIR) methods. Competitive adsorption experiments were also carried out using two solutions with different concentration levels at pH 7 to see the effect of competing ions. Phosphate adsorption was found to be effective and selective from solutions having trace amounts of competitive anions. It is expected that the novel PLE synthesized can be used for the removal of phosphate ions in low concentrations over a large range of pH.

  8. Preparation and use of crystalline bis-monoorganic phosphonate and phosphate salts of tetravalent metals

    DOEpatents

    Maya, L.

    1980-06-26

    A method of preparing and using the crystalline organic derivatives of the tetravalent metal phosphates and phosphonates provides for the contacting of an aqueous solution of a metal nitrate, with a solution of an organophosphorus acid for a period of time at room temperature that is sufficient for the formation of a metal phosphate product, and thereafter recovering said product. According to the invention, the product of the disclosed process is used in effecting analytical separations, such as ion exchange and chromatography.

  9. Bowel cleansing before colonoscopy: Balancing efficacy, safety, cost and patient tolerance

    PubMed Central

    Harrison, Nicole M; Hjelkrem, Michael C

    2016-01-01

    Effective colorectal cancer screening relies on reliable colonoscopy findings which are themselves dependent on adequate bowel cleansing. Research has consistently demonstrated that inadequate bowel preparation adversely affects the adenoma detection rate and leads gastroenterologists to recommend earlier follow up than is consistent with published guidelines. Poor preparation affects as many as 30% of colonoscopies and contributes to an increased cost of colonoscopies. Patient tolerability is strongly affected by the preparation chosen and manner in which it is administered. Poor tolerability is, in turn, associated with lower quality bowel preparations. Recently, several new developments in both agents being used for bowel preparation and in the timing of administration have brought endoscopists closer to achieving the goal of effective, reliable, safe, and tolerable regimens. Historically, large volume preparations given in a single dose were administered to patients in order to achieve adequate bowel cleansing. These were poorly tolerated, and the unpleasant taste of and significant side effects produced by these large volume regimens contributed significantly to patients’ inability to reliably complete the preparation and to a reluctance to repeat the procedure. Smaller volumes, including preparations that are administered as tablets to be consumed with water, given as split doses have significantly improved both the patient experience and efficacy, and an appreciation of the importance of the preparation to colonoscopy interval have produced additional cleansing. PMID:26788258

  10. Are bowel purgatives and prokinetics useful for small-bowel capsule endoscopy? A prospective randomized controlled study.

    PubMed

    Postgate, Aymer; Tekkis, Paris; Patterson, Neil; Fitzpatrick, Aine; Bassett, Paul; Fraser, Chris

    2009-05-01

    Capsule endoscopy (CE) is limited by incomplete small-bowel transit and poor view quality in the distal bowel. Currently, there is no consensus regarding the use of bowel purgatives or prokinetics in CE. To evaluate the usefulness of bowel purgatives and prokinetics in small-bowel CE. Prospective single-blind randomized controlled study. Academic endoscopy unit. A total of 150 patients prospectively recruited. Patients were randomized to 1 of 4 preparations: "standard" (fluid restriction then nothing by mouth 12 hours before the procedure, water and simethicone at capsule ingestion [S]); "standard" + 10 mg oral metoclopramide before the procedure (M); Citramag + senna bowel-purgative regimen the evening before CE (CS); Citramag + senna + 10 mg metoclopramide before the procedure (CSM). Gastric transit time (GTT) and small-bowel transit time (SBTT), completion rates (CR), view quality, and patient acceptability. positive findings, diagnostic yield. No significant difference was noted among groups for GTT (median [minutes] M, CS, and CSM vs S: 17.3, 24.7, and 15.1 minutes vs 16.8 minutes, respectively; P = .62, .18, and .30, respectively), SBTT (median [minutes] M, CS, and CSM vs S: 260, 241, and 201 vs 278, respectively; P = .91, .81, and .32, respectively), or CRs (85%, 85%, and 88% vs 89% for M, CS, and CSM vs S, respectively; P = .74, .74, and 1.00, respectively). There was no significant difference in view quality among groups (of 44: 38, 37, and 40 vs 37 for M, CS, and CSM, vs S, respectively; P = .18, .62, and .12, respectively). Diagnostic yield was similar among the groups. CS and CSM regimens were significantly less convenient (P < .001), and CS was significantly less comfortable (P = .001) than standard preparation. Bowel purgatives and prokinetics do not improve CRs or view quality at CE, and bowel purgatives reduce patient acceptability.

  11. The White Diet is preferred, better tolerated, and non-inferior to a clear-fluid diet for bowel preparation: A randomized controlled trial.

    PubMed

    Butt, Joshua; Bunn, Cate; Paul, Eldho; Gibson, Peter; Brown, Gregor

    2016-02-01

    Dietary restrictions contribute to the unpleasantness of bowel preparation for colonoscopy. We compare the effectiveness and tolerability of a low residue diet of white-colored foods ("White Diet") with a clear-fluid diet the day prior to colonoscopy in an endoscopist-blinded randomized non-inferiority trial. Adults undergoing outpatient colonoscopy were randomized with stratification by procedure timing to a White Diet or clear-fluid diet. All received a 2-L polyethylene glycol lavage solution with ascorbate, sodium sulfate, and electrolytes, the day-before for morning and as a split-dose for afternoon procedures. The primary end-point was successful bowel preparation (A or B on the Harefield Cleansing Scale). Regimen tolerance/acceptance was assessed by questionnaire. An intention-to-treat analysis with a predefined non-inferiority margin of 15% was used to compare efficacy. A total of 226 patients (average age 52 years, 51% male) were randomized (111 clear diet, 115 White Diet). Bowel preparation was successful in 91% on the clear-fluid diet vs 84.4% on the White Diet, difference being -6.6% (lower one sided 95% CI -13.8%), with no difference according to diet. The split-dose regimen (in 55%) had a higher success rate than day-before regimen (96% vs 80%, p < 0.001). The White Diet was preferred with less hunger and interference with daily activities (p < 0.001). Procedural/withdrawal time and polyp/adenoma detection were similar between groups. The White Diet was preferred and better tolerated by patients without detriment to the success of bowel preparation or colonoscopy performance, especially with the split-dose regimen. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  12. CT colonography with reduced bowel preparation after incomplete colonoscopy in the elderly.

    PubMed

    Iafrate, F; Hassan, C; Zullo, A; Stagnitti, A; Ferrari, R; Spagnuolo, A; Laghi, A

    2008-07-01

    We prospectively assessed the feasibility and acceptance of computerized tomographic colonography (CTC) without bowel cathartic preparation in elderly patients after incomplete colonoscopy. A total of 136 patients underwent CTC without cathartic preparation. The time delay between conventional colonoscopy and CTC ranged between 3 and 20 days, depending on the clinical situation. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. CTCs were interpreted using a primary two-dimensional (2D) approach and 3D images for further characterization. Patients were interviewed before and 2 weeks after CTC to assess preparation acceptance. CTC was feasible and technically successful in all the 136 patients. Fecal tagging was judged as excellent in 113 (83%) patients and sufficient in 23 (17%). Average CT image interpretation time was 14.8 min. Six (4.4%) cases of colorectal cancer and nine (6.6%) large polyps were detected, as well as 23 (11.3%) extracolonic findings of high clinical importance. No major side effect occurred, although 25% patients reported minor side effects, especially diarrhea. Overall, 76/98 patients replied that they would be willing to repeat the test if necessary. CTC without cathartic preparation is a technically feasible and safe procedure to complete a colonic study in the elderly, prompting its use in clinical practice.

  13. Polyethylene glycol 3350 without electrolytes: a new safe, effective, and palatable bowel preparation for colonoscopy in children.

    PubMed

    Pashankar, Dinesh S; Uc, Aliye; Bishop, Warren P

    2004-03-01

    To assess safety, efficacy, and acceptance of polyethylene glycol 3350 without electrolytes (PEG) for bowel preparation for colonoscopy in children. Study design In a prospective study, 46 children (mean age, 11.2 years; range, 2.8-17.8) were given PEG at a dose of 1.5 g/kg/day for 4 days before colonoscopy. Patients were allowed to mix PEG in the beverage of their choice. Stool frequency and adverse effects were monitored during PEG therapy. Compliance, tolerance, and quality of colonic preparation were assessed. Serum electrolytes were measured before and after PEG therapy in 29 children. Daily stool frequency increased with PEG therapy from baseline of 2.6+/-0.3 to 3.0+/-0.5 on day 1, 4.6+/-0.4 on day 2, 5.5+/-0.7 on day 3, and 6.0+/-0.6 on day 4 (days 2, 3, and 4, P<.001 for difference vs baseline). The colonic preparations were rated as excellent or good in 91% and 95% in the right and left colon, respectively, at endoscopy. Adverse effects were mild nausea (13%), abdominal pain (11 %), and vomiting (11%). Electrolyte profile revealed small, clinically insignificant changes with PEG therapy. Compliance and tolerance were rated as excellent by 89% and 85% of patients, respectively. Electrolyte-free PEG 3350 can be used as an effective and safe bowel preparation that is well accepted by children for colonoscopy.

  14. Lubiprostone neither decreases gastric and small-bowel transit time nor improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled study.

    PubMed

    Hooks, S Bennett; Rutland, Travis J; Di Palma, Jack A

    2009-11-01

    Lubiprostone, a selective activator of type 2 chloride channels, is approved for treatment of chronic idiopathic constipation and recently constipation-predominant irritable bowel syndrome. It has been suggested that lubiprostone has a prokinetic effect. This investigation was designed to evaluate lubiprostone as a preparation and propulsive agent for small-bowel capsule endoscopy. The PillCam Small Bowel capsule endoscopy system with the PillCam SB1 capsule and Rapid 5 software platform were used. The study was designed as a double-blind, placebo-controlled trial. Forty healthy adults. Gastric transit time (GTT), small-bowel transit time (SBTT), and adequacy of small-bowel cleansing preparation. The study subjects received 24 mug lubiprostone or placebo 30 minutes before PillCam capsule ingestion. Capsule endoscopy studies were read by 2 independent investigators unaware of the study medication received, and differences in interpretation were resolved by consensus. Anatomical landmarks were identified, and GTT and SBTT were calculated. Overall preparation quality assessment of the proximal, mid, and distal small bowel was determined by using a 4-step scale. The percentage of visualized bowel was determined by review of 10-minute video segments at 1-hour intervals after the capsule passed through the pylorus. In the lubiprostone group (n = 20), 2 subjects did not pass the capsule through the pylorus in the 8-hour battery life of the capsule. An additional 3 capsules did not pass into the colon. In the placebo group (n = 20), all capsules passed into the small bowel, but 1 did not pass into the colon. The subjects in whom the capsule did not pass into the small bowel were excluded from the small-bowel analysis. In the subjects in whom the capsule did reach the colon, the SBTT could not be calculated and they were excluded from SBTT analysis. The mean GTT in the lubiprostone group was 126 minutes and 43 minutes in the placebo group (P = .0095). The mean SBTT in the

  15. Comparative evaluation of Nano-Hydroxyapatite preparation and Calcium Sucrose Phosphate on microhardness of deciduous teeth after iron drop exposure - An in-vitro study.

    PubMed

    Rathi, Nilesh; Baid, Rutika; Baliga, Sudhindra; Thosar, Nilima

    2017-04-01

    To evaluate and compare the microhardness of deciduous teeth treated with nano-hydroxyapatite and calcium sucrose phosphate after iron drop exposure. Twenty healthy anterior deciduous teeth were collected and stored in 0.9% saline solution at room temperature. All the teeth were immersed in artificial saliva in an incubator shaker at 37° for an hour and then subjected to Vickers microhardness test at 100g load for 5 seconds. The teeth were then immersed in iron drop for 5 minutes, twice daily, rinsed with distilled water and kept in artificial saliva. This procedure was repeated for 7 days and teeth were subjected to microhardness testing. Further, the teeth were divided in two groups, each group containing 10 teeth. In group I, nanohydroxyapatite preparation and in group II, calcium sucrose phosphate were applied for 10 minutes, twice daily for 7 days and subjected again to microhardness testing again. Vickers microhardness analysis revealed that iron drop exposure to teeth caused significant decrease in microhardness ( p <0.05). Application of nanohydroxyapatite preparation in Group I showed significantly increased enamel microhardness (206.90) than that after iron drop exposure. Similarly, application of calcium sucrose phosphate in Group II showed significantly increased enamel microhardness (200.89) than that after iron drop exposure. Statistical difference was seen between the two groups, with nanohydroxyapatite preparation showing increased microhardness than calcium sucrose phosphate. Nanohydroxyapatite preparation and calcium sucrose phosphate have remineralizing effect over teeth affected by acid challenge of iron drops, nanohydroxyapatite preparation showing better results than calcium sucrose phosphate. Key words: Iron drops, Nanohydroxyapaptite, calcium sucrose phosphate, anticay.

  16. A prospective randomized single blind trial of Fleet phosphate enema versus glycerin suppositories as preparation for flexible sigmoidoscopy.

    PubMed

    Underwood, D; Makar, R R; Gidwani, A L; Najfi, S M; Neilly, P; Gilliland, R

    2010-03-01

    This study compared the efficacy and patient acceptability of two methods of bowel preparation for flexible sigmoidoscopy. Patients attending for outpatient flexible sigmoidoscopy were prospectively randomized to receive one Fleet ready-to-use enema or 2 x 4 g glycerin suppositories, 2 h preprocedure. Patient and endoscopist questionnaires were used to compare the outcomes. From November 2000 to August 2001, 203 (male = 95; female = 108) patients were randomized. Patient data available for 163 patients (enema = 93; suppository = 70) revealed: ease of use (enema = 52; suppository = 25; P < 0.02, Fisher's exact); assistance required (enema = 19; suppository = 3; P < 0.005, Fisher's exact); grade of effectiveness (enema = 83; suppository = 44; P < 0.0001, Fisher's exact), and whether patients wished to try another preparation in future (enema = 16; suppository = 24; P = 0.016, Fisher's exact). Endoscopist data available for 151 patients (enema = 76; suppository = 75) revealed: average depth of insertion (enema = 53.6 +/- 11.6 cm; suppository 46.3 +/- 13.7 cm; P < 0.001, Student's t test); acceptable (excellent + good) quality of preparation [enema = 60 (78.9%); suppository = 34 (45.3%); P < 0.0001, Fisher's exact]. Bowel preparation for flexible sigmoidoscopy using a single Fleet enema is acceptable to patients and more effective than glycerin suppositories.

  17. Modulation of sphingosine-1-phosphate in inflammatory bowel disease.

    PubMed

    Peyrin-Biroulet, Laurent; Christopher, Ronald; Behan, Dominic; Lassen, Cheryl

    2017-05-01

    Inflammatory bowel diseases (IBD), including ulcerative colitis and Crohn's disease, involve an inappropriate immune reaction in the digestive tract, causing a variety of disabling symptoms. The advent of monoclonal antibodies (anti-tumor necrosis factor, anti-integrin, anti-interleukin -23) has revolutionized IBD management. Nevertheless, these agents, with potential for immunogenicity, are associated with high rates of response loss and disease relapse over time. They are also associated with high production costs. Sphingosine-1-phosphate (S1P), a membrane-derived lysophospholipid signaling molecule, is implicated in a vast array of physiological and pathophysiological processes, primarily via extracellular activation of S1P1-S1P5 receptors. S1P1, S1P4 and S1P5 are involved in regulation of the immune system, while S1P2 and S1P3 may be associated with cardiovascular, pulmonary, and theoretical cancer-related risks. Targeting S1P receptors for inflammatory conditions has been successful in clinical trials leading to approval of the non-selective S1P modulator, fingolimod, for relapsing forms of multiple sclerosis. However, the association of this non-selective S1P modulator with serious adverse events provides the rationale for developing more selective S1P receptor modulators. Until recently, three S1P modulators with differing selectivity for S1P receptors were in clinical development for IBD: ozanimod (RPC1063), etrasimod (APD334) and amiselimod (MT-1303). The development of amiselimod has been stopped as Biogen are currently focusing on other drugs in its portfolio. Following encouraging results from the Phase 2 TOUCHSTONE trial, a Phase 3 trial of the S1P modulator ozanimod in patients with moderate-to-severe ulcerative colitis is ongoing. Etrasimod is also being tested in a phase 2 trial in ulcerative colitis. These pipeline medications can be administered orally and may avoid the formation of anti-drug antibodies that can lead to treatment failure with

  18. Preparation of micro-porous bioceramic containing silicon-substituted hydroxyapatite and beta-tricalcium phosphate.

    PubMed

    Fuh, Lih-Jyh; Huang, Ya-Jing; Chen, Wen-Cheng; Lin, Dan-Jae

    2017-06-01

    Dimensional instability caused by sintering shrinkage is an inevitable drawback for conventional processing of hydroxyapatite (HA). A new preparation method for biphasic calcium phosphates was developed to increase micro pores and biodegradation without significant dimensional change. Powder pressed HA discs, under 100MPa, were immersed in a colloidal mixture of tetraethoxysilane (TEOS) and ammonium hydroxide for 10min, followed by drying, and then were sintered at 900°C, 1050°C, and 1200°C, respectively. Comparing with pure HA discs, the newly prepared product sintered up to 1200°C contained silicon substituted HA, beta-tricalcium phosphate, and calcium silicate with better micro-porosity, high specific surface area, less sintering shrinkage and the strength maintained. The cytocompatibility test demonstrated a better viability for D1 mice stem cells cultured on TEOS treated HA for 14days compared to the pure HA. This simple TEOS sol-gel pretreatment has the potential to be applied to any existing manufacturing process of HA scaffold for better control of sintering shrinkage, create micropores, and increase biodegradation. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The impact of diet liberalization on bowel preparation for colonoscopy.

    PubMed

    Walter, James; Francis, Gloria; Matro, Rebecca; Kedika, Ramalinga; Grosso, Rachael; Keith, Scott W; Kastenberg, David

    2017-04-01

    Background and study aims  Dietary restrictions are integral to colonoscopy preparation and impact patient satisfaction. Utilizing split-dose, lower-volume polyethylene glycol 3350-electrolyte solution (PEG-ELS), this study compared colon preparation adequacy of a low-residue diet to clear liquids using a validated grading scale. Patients and methods  This was a prospective, randomized, single-blinded, single-center non-inferiority study evaluating diet the day prior to outpatient colonoscopy. Subjects were randomized to a Low-Residue diet for breakfast and lunch, or Clears only. All subjects received split dose PEG-ELS. The primary endpoint was preparation adequacy using the Boston Bowel Preparation Scale (BBPS), with adequate defined as a score > 5. Secondary endpoints included mean BBPS scores for the entire colon and individual segments, satisfaction, adverse events, polyp and adenoma detection rates, and impact on sleep and daily activities. Results  Final analysis included 140 subjects, 72 assigned to Clears and 68 to Low-Residue. The Low-Residue diet was non-inferior to Clears (risk difference = - 5.08 %, P  = 0.04) after adjusting for age. Mean colon cleansing scores were not significantly different overall and for individual colonic segments. Satisfaction with the Low-Residue diet was significantly greater ( P  = 0.01). The adenoma detection rate was not statistically significantly different between study groups, but the number of adenomas detected was significantly greater with Clears ( P  = 0.01). Adverse events and impact on sleep and activities did not differ significantly between diet arms. Conclusions  A low-residue diet for breakfast and lunch the day prior to colonoscopy was non-inferior to clear liquids alone for achieving adequate colon cleansing when using split dose PEG-ELS.

  20. Safety of a 1-Day Polyethylene Glycol 3350 Bowel Preparation for Colonoscopy in Children.

    PubMed

    Sahn, Benjamin; Chen-Lim, Mei Lin; Ciavardone, Denise; Farace, Lisa; Jannelli, Frances; Nieberle, Megan; Ely, Elizabeth; Zhang, Xuemei; Kelsen, Judith; Puma, Anita; Mamula, Petar

    2016-07-01

    Electrolyte-free polyethylene glycol powder (PEG-3350) has been widely used for colonoscopy preparation (prep); however, limited safety data on electrolyte changes exists with 1-day prep regimens. The primary aim of this study was to determine the proportion of patients with significant serum chemistry abnormalities before and at the time of colonoscopy. Secondary aims included evaluation of prep tolerance and bowel cleansing efficacy. We performed a prospective descriptive observational study of pediatric patients scheduled for outpatient colonoscopy who received our standard 1-day, weight-based 4 g/kg PEG-3350 prep with a single stimulant laxative dose and had serum chemistry testing within 60 days before and at the time of colonoscopy. A standardized bowel cleanliness tool (Aronchick scale) was completed by the endoscopist. One hundred fifty-five patients had serum electrolytes data pre- and postprep. Comparison of each patient's chemistries demonstrated statistical equivalence with the 1 exception of blood urea nitrogen levels (P = 0.56). Hypokalemia was detected postprep in 37 subjects (24%), but none had a serum level <3.3 mmol/L, which was deemed to be of no clinical significance. Five patients were hypoglycemic post prep; 3 were 7 years or younger (P = 0.02). The colon cleanliness rating was excellent or good in 77% and suboptimal in 23% of patients. A 1-day, weight-based PEG-3350 bowel prep in children appears safe. Changes in electrolyte levels and renal function were not clinically significant. Children of 7 years or younger seem to be at a higher risk of hypoglycemia compared with older children.

  1. Preparation of in situ hardening composite microcarriers: Calcium phosphate cement combined with alginate for bone regeneration

    PubMed Central

    Park, Jung-Hui; Lee, Eun-Jung; Knowles, Jonathan C

    2014-01-01

    Novel microcarriers consisting of calcium phosphate cement and alginate were prepared for use as three-dimensional scaffolds for the culture and expansion of cells that are effective for bone tissue engineering. The calcium phosphate cement-alginate composite microcarriers were produced by an emulsification of the composite aqueous solutions mixed at varying ratios (calcium phosphate cement powder/alginate solution = 0.8–1.2) in an oil bath and the subsequent in situ hardening of the compositions during spherodization. Moreover, a porous structure could be easily created in the solid microcarriers by soaking the produced microcarriers in water and a subsequent freeze-drying process. Bone mineral-like apatite nanocrystallites were shown to rapidly develop on the calcium phosphate cement–alginate microcarriers under moist conditions due to the conversion of the α-tricalcium phosphate phase in the calcium phosphate cement into a carbonate–hydroxyapatite. Osteoblastic cells cultured on the microspherical scaffolds were proven to be viable, with an active proliferative potential during 14 days of culture, and their osteogenic differentiation was confirmed by the determination of alkaline phosphatase activity. The in situ hardening calcium phosphate cement–alginate microcarriers developed herein may be used as potential three-dimensional scaffolds for cell delivery and tissue engineering of bone. PMID:23836845

  2. A dual-action, low-volume bowel cleanser administered the day before colonoscopy: results from the SEE CLEAR II study.

    PubMed

    Katz, Philip O; Rex, Douglas K; Epstein, Michael; Grandhi, Nav K; Vanner, Stephen; Hookey, Lawrence C; Alderfer, Vivian; Joseph, Raymond E

    2013-03-01

    Optimal bowel preparation is vital for the efficacy and safety of colonoscopy. The inconvenience, discomfort, required consumption of large volumes of product, and potential adverse effects associated with some bowel preparations deter patients from colonoscopy and may provide inadequate cleansing. A dual-action, non-phosphate, natural orange-flavored, low-volume preparation containing sodium picosulfate and magnesium citrate (P/MC) is currently being reviewed for bowel cleansing. This was a phase 3, randomized, multicenter, assessor-blinded, prespecified non-inferiority, head-to-head study to investigate the efficacy, safety, and tolerability of day-before administration of P/MC vs. 2L polyethylene glycol solution and two 5-mg bisacodyl tablets (2L PEG-3350 and bisacodyl tablets (HalfLytely and Bisacodyl Tablets Bowel Prep Kit)) in adult patients preparing for colonoscopy (SEE CLEAR II Study). The primary objective of the study was to demonstrate the non-inferiority of P/MC to 2L PEG-3350 and bisacodyl tablets in overall colon cleansing using a modified Aronchick scale. In addition, efficacy in the ascending, mid (transverse and descending), and recto-sigmoid segments of colon was evaluated using a modified Ottawa scale. Patient acceptability and tolerability of the bowel preparations were assessed via a standard questionnaire. Safety was assessed based on the monitoring of adverse events (AEs) and meaningful findings on clinical evaluations including physical examinations, vital sign measurements, and electrocardiograms (ECGs). A total of 603 patients were randomized to receive either P/MC (n = 300) or 2L PEG-3350 and bisacodyl tablets (n = 303). Based on the Aronchick scale, successful overall cleansing was similar in patients receiving P/MC (83.0%) and patients receiving 2L PEG-3350 and bisacodyl tablets (79.7%). P/MC demonstrated non-inferiority to 2L PEG-3350 and bisacodyl tablets in overall cleansing of the colon, as measured by the Aronchick scale

  3. Comparison between oral antibiotics and probiotics as bowel preparation for elective colon cancer surgery to prevent infection: prospective randomized trial.

    PubMed

    Sadahiro, Sotaro; Suzuki, Toshiyuki; Tanaka, Akira; Okada, Kazutake; Kamata, Hiroko; Ozaki, Toru; Koga, Yasuhiro

    2014-03-01

    We have already reported that, for patients undergoing elective colon cancer operations, perioperative infection can be prevented by a single intravenous dose of an antibiotic given immediately beforehand if mechanical bowel preparation and the administration of oral antibiotics are implemented. Synbiotics has been reported to reduce the rate of infection in patients after pancreatic cancer operations. The effectiveness of oral antibiotics and probiotics in preventing postoperative infection in elective colon cancer procedures was examined in a randomized controlled trial. Three hundred ten patients with colon cancer randomly were assigned to one of three groups. All patients underwent mechanical bowel preparation and received a single intravenous dose of flomoxef immediately before operation. Probiotics were administered in Group A; oral antibiotics were administered in Group B; and neither probiotics nor oral antibiotics were administered in Group C. Stool samples were collected 9 and 2 days before and 7 and 14 days after the procedure. Clostridium difficile toxin and the number of bacteria in the intestine were determined. The rates of incisional surgical-site infection were 18.0%, 6.1%, and 17.9% in Groups A, B, and C, and the rates of leakage were 12.0%, 1.0%, and 7.4% in Groups A, B, and C, respectively, indicating that both rates were lesser in Group B than in Groups A and C (P = .014 and P = .004, respectively). The detection rates of C. difficile toxin were not changed among the three groups. We recommend oral antibiotics, rather than probiotics, as bowel preparation for elective colon cancer procedures to prevent surgical-site infections. Copyright © 2014 Mosby, Inc. All rights reserved.

  4. Addition of simethicone improves small bowel capsule endoscopy visualisation quality.

    PubMed

    Krijbolder, M S; Grooteman, K V; Bogers, S K; de Jong, D J

    2018-01-01

    Small bowel capsule endoscopy (SBCE) is an important diagnostic tool for small-bowel diseases but its quality may be hampered by intraluminal gas. This study evaluated the added value of the anti-foaming agent, simethicone, to a bowel preparation with polyethylene glycol (PEG) on the quality of small bowel visualisation and its use in the Netherlands. This was a retrospective, single-blind, cohort study. Patients in the PEG group only received PEG prior to SBCE. Patients in the PEG-S group ingested additional simethicone. Two investigators assessed the quality of small-bowel visualisation using a four-point scale for 'intraluminal gas' and 'faecal contamination'. By means of a survey, the use of anti-foaming agents was assessed in a random sample of 16 Dutch hospitals performing SBCE. The quality of small bowel visualisation in the PEG group (n = 33) was significantly more limited by intraluminal gas when compared with the PEG-S group (n = 31): proximal segment 83.3% in PEG group vs. 18.5% in PEG-S group (p < 0.01), distal segment 66.7% vs. 18.5% respectively (p < 0.01). No difference was observed in the amount of faecal contamination (proximal segment 80.0% PEG vs. 59.3% PEG-S, p = 0.2; distal segment 90.0% PEG vs. 85.2% PEG-S, p = 0.7), mean small bowel transit times (4.0 PEG vs. 3.9 hours PEG-S, p = 0.7) and diagnostic yield (43.3% PEG vs. 22.2% PEG-S, p = 0.16). Frequency of anti-foaming agent use in the Netherlands was low (3/16, 18.8%). Simethicone is of added value to a PEG bowel preparation in improving the quality of visualisation of the small bowel by reducing intraluminal gas. At present, the use of anti-foaming agents in SBCE preparation is not standard practice in the Netherlands.

  5. A Comparative Study of Treatment-Emergent Adverse Events Following Use of Common Bowel Preparations Among a Colonoscopy Screening Population: Results from a Post-Marketing Observational Study.

    PubMed

    Anastassopoulos, Kathryn; Farraye, Francis A; Knight, Tyler; Colman, Sam; Cleveland, Mark vB; Pelham, Russell W

    2016-10-01

    Colonoscopy may be one of the most frequent elective procedures in older adults and is associated with a low occurrence of complications. However, reduction of risks attributable to the bowel preparation may be achieved with the use of effective and safer products. The aim of this study was to examine the incidence of treatment-emergent adverse events (TEAEs) associated with SUPREP(®) [oral sulfate solution (OSS)] and other common prescription bowel preparations (non-OSS). This real-world, observational study used de-identified health insurance claims and laboratory results to identify TEAEs in the 3 months following screening colonoscopy in adults with a prescription for a bowel preparation in the prior 60 days. The unadjusted and adjusted (controlling for patient risk factors) cumulative incidences of TEAEs were estimated using Kaplan-Meier and Poisson regression, respectively. Among patients ≥45 years, the overall cumulative incidence was significantly lower (p < 0.001) in the OSS cohort than in the non-OSS cohort (unadjusted: 2.31 vs. 2.89 %; adjusted: 1.61 vs. 1.95 %), with significantly lower acute cardiac conditions (1.56 vs. 1.90 %; p < 0.001), renal failure/other serious renal diseases (OSS: 0.21 %, non-OSS: 0.32 %; p < 0.001), and serum electrolyte abnormalities (OSS: 0.39 %, non-OSS: 0.49 %; p = 0.017). There were no significant differences between cohorts in death, seizure disorders, aggravation of gout, and ischemic colitis. Results were similar in the adjusted cumulative incidences. In actual use, the overall cumulative incidence of TEAEs was significantly lower in the OSS cohort, demonstrating that OSS is as safe as, or possibly safer than, non-OSS prescription bowel preparations.

  6. CADMIUM PHOSPHATE GLASS

    DOEpatents

    Carpenter, H.W.; Johnson, P.D.

    1963-04-01

    A method of preparing a cadmium phosphate glass that comprises providing a mixture of solid inorganic compounds of cadmuim and phosphate having vaporizable components and heating the resulting composition to a temperature of at least 850 un. Concent 85% C is presented. (AEC)

  7. Bowel Retraining: Strategies for Establishing Bowel Control

    MedlinePlus

    ... Us Search Bowel Retraining: Strategies for Establishing Bowel Control Home Bowel Retraining Details Treatment Last Updated: 29 ... help people with bowel disorders establish or reestablish control. Individuals with symptoms of inability to control bowel ...

  8. Polyethylene Glycol-3350 (Miralax®)+1.9-L sports drink (Gatorade®)+2 tablets of bisacodyl results in inferior bowel preparation for colonoscopy compared with Polyethylene Glycol-Ascorbic Acid (MoviPrep®).

    PubMed

    Khan, Maqsood Ahmed; Patel, Kevin B; Nooruddin, Mohammed; Swanson, Garth; Fogg, Louis; Keshavarzian, Ali; Brown, Michael

    2018-01-01

    Polyethylene glycol (PEG)-3350, approved by Food and Drug Administration (FDA) only for constipation, combined with 1.9 L of sports drink (SD) (GatoradeR) and bisacodyl (B) is commonly used in outpatient practice for bowel preparation due to cited patient satisfaction and tolerability of this specific regimen. We aim to compare PEG-3350 (MiralaxR) with PEG-AA-based (MoviPrepR) in terms of efficacy, patient satisfaction, and the effects of these two regimen on serum electrolytes. This study is a prospective, single-blinded, block randomized trial comparing single-dose PEG-3350+SD+B to split-dose 2-L PEG-AA in the outpatient endoscopy unit in patients undergoing colonoscopy. Basic metabolic profiles were checked on the day of randomization and on the day of procedure. Patients completed a survey on the day of procedure. Bowel preparation quality was assessed using the Boston Bowel Preparation Scale (BBPS) by two endoscopists and a nurse present during the procedure. We randomized 150 patients (74 PEG-3350+SD+B and 76 PEG-AA). The PEG-AA group had significantly higher BBPS scores in the right colon by Endoscopist 1, Nurse, and Endoscopist 2 (p 0.005, <0.000, 0.001) and in the left and transverse colon by Nurse and Endoscopist 2 (p 0.004, 0.26, 0.000, 0.006). There was no statistically significant difference in patient satisfaction or change in serum electrolytes between the two groups. Use of single-dose PEG-3350+SD+B results in inferior bowel preparation for colonoscopy compared with split-dose PEGAA and does not provide any advantage in regards to patient satisfaction. We therefore recommend discontinuing the use of PEG 3350 for bowel preparation.

  9. Hyperphosphatemia after sodium phosphate laxatives in low risk patients: Prospective study

    PubMed Central

    Casais, Marcela Noemi; Rosa-Diez, Guillermo; Pérez, Susana; Mansilla, Elina Noemi; Bravo, Susana; Bonofiglio, Francisco Carlos

    2009-01-01

    AIM: To establish the frequency of hyperphosphatemia following the administration of sodium phosphate laxatives in low-risk patients. METHODS: One hundred consecutive ASA I-II individuals aged 35-74 years, who were undergoing colonic cleansing with oral sodium phosphate (OSP) before colonoscopy were recruited for this prospective study. Exclusion criteria: congestive heart failure, chronic kidney disease, diabetes, liver cirrhosis, intestinal obstruction, decreased bowel motility, increased bowel permeability, and hyperparathyroidism. The day before colonoscopy, all the participants entered a 24-h period of diet that consisted of 4 L of clear fluids with sugar or honey and 90 mL (60 g) of OSP in two 45-mL doses, 5 h apart. Serum phosphate was measured before and after the administration of the laxative. RESULTS: The main demographic data (mean ± SD) were: age, 58.9 ± 8.4 years; height, 163.8 ± 8.6 cm; weight, 71 ± 13 kg; body mass index, 26 ± 4; women, 66%. Serum phosphate increased from 3.74 ± 0.56 to 5.58 ± 1.1 mg/dL, which surpassed the normal value (2.5-4.5 mg/dL) in 87% of the patients. The highest serum phosphate was 9.6 mg/dL. Urea and creatinine remained within normal limits. Post-treatment OSP serum phosphate concentration correlated inversely with glomerular filtration rate (P < 0.007, R2 = 0.0755), total body water (P < 0.001, R2 = 0.156) and weight (P < 0.013, R2 = 0.0635). CONCLUSION: In low-risk, well-hydrated patients, the standard dose of OSP-laxative-induced hyperphosphatemia is related to body weight. PMID:20014460

  10. Socioeconomic and other predictors of colonoscopy preparation quality.

    PubMed

    Lebwohl, Benjamin; Wang, Timothy C; Neugut, Alfred I

    2010-07-01

    Suboptimal bowel preparation prior to colonoscopy is a common occurrence, with a deleterious impact on colonoscopy effectiveness. Established risk factors for suboptimal bowel preparation have been proposed, but social factors, such as socioeconomic status and marital status, have not been investigated. The aim of this study was to evaluate sociodemographic factors, including insurance status and marital status, as predictive of suboptimal preparation. We analyzed a database of 12,430 consecutive colonoscopies during a 28-month period at Columbia University Medical Center. We collected the following variables: age, gender, indication for colonoscopy, location (inpatient vs. outpatient), race, marital status, and Medicaid status. Preparation quality was recorded and dichotomized as optimal or suboptimal. We employed multivariate regression to determine independent risk factors for suboptimal bowel preparation. Among the 10,921 examinations in which bowel preparation was recorded, suboptimal preparation occurred in 34% of Medicaid patients versus 18% of non-Medicaid patients (P < 0.0001); this remained significant in the multivariate analysis (odds ratio (OR) 1.84, 95% CI 1.61-2.11). Married patients had decreased rates of suboptimal preparation (OR 0.89, 95% CI 0.80-0.98). Other variables associated with suboptimal preparation included increased age (OR per 10 years 1.09, 95% CI 1.05-1.14), male gender (OR 1.44, 95% CI 1.31-1.59), inpatient status (OR 1.51, 95% CI 1.26-1.80), and later time of day (OR 1.89, 95% CI 1.71-2.09). Unmarried status and Medicaid status are predictive of suboptimal bowel preparation. Future studies are warranted to identify how these social conditions predict bowel preparation quality and to implement interventions to optimize bowel preparation in vulnerable populations.

  11. MiraLAX is not as effective as GoLytely in bowel cleansing before screening colonoscopies.

    PubMed

    Hjelkrem, Michael; Stengel, Joel; Liu, Mark; Jones, David P; Harrison, Stephen A

    2011-04-01

    Successful colonoscopies require good bowel preparations-poor bowel preparations can increase medical costs, rates of missed lesions, and procedure duration. The combination of polyethylene glycol (PEG) 3350 without electrolytes (MiraLAX; Schering-Plough Healthcare Products, Inc, Kenilworth, NJ) and 64 oz of Gatorade (PepsiCo, Inc, Purchase, NY) has gained popularity as a bowel preparation regimen. However, the efficacy and tolerability of this approach has not been compared with standard bowel preparations in clinical trials. We compared split-dose (PEG) 3350 with electrolytes (GoLytely; Braintree Laboratories, Inc, Braintree, MA) with split-dose MiraLAX alone and in combination with pretreatment medications (bisacodyl or lubiprostone) to determine the efficacy and patient tolerability of MiraLAX as an agent for bowel preparation. We performed a prospective, randomized, blinded, controlled trial at a tertiary care center. Patients (n=403) were randomly assigned to groups given GoLytely, MiraLAX, MiraLAX with bisacodyl (10 mg), or MiraLAX with lubiprostone (24 μg). MiraLAX was combined with 64 oz of Gatorade. All patients were surveyed regarding preparation satisfaction and tolerability. The Ottawa bowel preparation scale was used to grade colon cleanliness. GoLytely was more effective at bowel cleansing (average Ottawa score, 5.1) than MiraLAX alone (average Ottawa score, 6.9) or in combination with lubiprostone (average Ottawa score, 6.8), or bisacodyl (average Ottawa score, 6.3) (P<.001). MiraLAX was associated with a trend toward longer procedure duration (P=.096). Groups given MiraLAX rated the overall experience as more satisfactory than those given GoLytely (P<.001). There were no differences between polyp detection rates (P=.346) or adverse events (P=.823). Split-dose MiraLAX in 64 oz of Gatorade is not as effective as 4 L split-dose GoLytely in bowel cleansing for screening colonoscopies. Copyright © 2011 AGA Institute. Published by Elsevier Inc. All

  12. A randomized, blinded, prospective trial to compare the safety and efficacy of three bowel-cleansing solutions for colonoscopy (HSG-01*).

    PubMed

    Ell, C; Fischbach, W; Keller, R; Dehe, M; Mayer, G; Schneider, B; Albrecht, U; Schuette, W

    2003-04-01

    There are conflicting data regarding the optimal bowel preparation for colonoscopy. This study was carried out to compare the efficacy, safety, and tolerability of three widely used bowel lavage solutions: the standard polyethylene glycol-electrolyte solution based on the GoLytely formulation (PEG-EL1; Klean-Prep); a sulphate-free PEG-EL solution based on the NuLytely formulation (PEG-EL2, Endofalk); and a sodium phosphate preparation (NaP, Fleet Phospho-Soda). A total of 185 consecutive patients scheduled for elective colonoscopy were prospectively randomly assigned to undergo pre-colonoscopic bowel cleansing with either 4 l of PEG-EL1 (n=64), 3 l of PEG-EL2 (n=59), or 90 ml of NaP (n=62). The quality of preparatory colonic cleansing for each segment from the rectum to the ascending colon was scored on a five-level rating scale (1, very good to 5, very poor) by endoscopists who were blinded with regard to the type of preparation used. The primary outcome measure for the comparison of treatments was the "worst" score in any of the rated bowel segments. Safety and tolerability were evaluated by means of a symptom questionnaire completed by each patient immediately before the procedure. Of the 185 patients who were randomly assigned to one of the three treatments, 175 underwent colonoscopy and 173 were evaluable with regard to efficacy - 59, 54, and 60 patients treated with PEG-EL1, PEG-EL2, and NaP, respectively. The treatment groups were comparable with regard to the baseline characteristics. PEG-EL1 was statistically significantly superior to the other treatments in relation to the "worst cleansing" score ( Pbowel segments and general "very good" or "good" ratings were achieved in more than 90 % of patients treated with PEG-EL1. The percentages were consistently lower in the other two groups, particularly in the ascending colon. With the exception of the sigmoid, the

  13. Optimization of calcium phosphate fine ceramic powders preparation

    NASA Astrophysics Data System (ADS)

    Sezanova, K.; Tepavitcharova, S.; Rabadjieva, D.; Gergulova, R.; Ilieva, R.

    2013-12-01

    The effect of biomimetic synthesis method, reaction medium and further precursor treatments on the chemical and phase composition, crystal size and morphology of calcium phosphates was examined. Nanosized calcium phosphate precursors were biomimetically precipitated by the method of continuous precipitation in three types of reaction media at pH 8: (i) SBF as an inorganic electrolyte system; (ii) organic (glycerine) modified SBF (volume ratio of 1:1); (iii) polymer (10 g/l xanthan gum or 10 g/l guar gum) modified SBF (volume ratio of 1:1). After maturation (24 h) the samples were lyophilized, calcinated at 300°C for 3 hours, and washed with water, followed by new gelation, lyophilization and step-wise (200, 400, 600, 800, and 1000°C, each for 3 hours) sintering. The reaction medium influenced the chemical composition and particle size but not the morphology of the calcium phosphate powders. In all studied cases bi-phase calcium phosphate fine powders with well-shaped spherical grains, consisting of β-tricalcium phosphate (β-TCP) and hydroxyapatite (HA) with a Ca/P ratio of 1.3 - 1.6 were obtained. The SBF modifiers decreased the particle size of the product in the sequence guar gum ˜ xanthan gum < glycerin < SBF medium.

  14. A prospective audit of the efficacy, safety, and acceptability of low-volume polyethylene glycol (2 L) versus standard volume polyethylene glycol (4 L) versus magnesium citrate plus stimulant laxative as bowel preparation for colonoscopy.

    PubMed

    Kelly, Nicholas Michael; Rodgers, Colin; Patterson, Neil; Jacob, Sudheer George; Mainie, Inder

    2012-08-01

    High-quality video colonoscopy requires adequate preparation of the bowel to ensure both adequate procedure completion rates and polyp detection rates. We sought to examine our practice to determine which bowel preparation cleansed most effectively in our patients. A prospective audit of the efficacy, safety, and acceptability of low-volume polyethylene glycol (2-L Moviprep; Norgine Pharmaceuticals) versus standard volume polyethylene glycol (4-L KleanPrep; Norgine Pharmaceuticals) versus magnesium citrate (Citramag; Sanochemia UK Ltd.) plus stimulant laxative as bowel preparation for colonoscopy. District General Hospital. Patients attending for day case colonoscopy. Not applicable. Overall cleansing grades of preparations used: patient compliance, taste, and acceptability. A prospective audit of patient experience of taking bowel preparation and blinded colonic scoring assessment of bowel cleansing of each of the tested regimes. A total of 258 (female,138; 53.5%) patients were recruited, 91 in the KleanPrep group (F:45, 49.5%), 86 patients in the Moviprep group (female, 45; 52.3%), and 81 in the Senna/Citramag group (female, 44; 54.3%). Significantly more patients were unable to take the prescribed dose of KleanPrep when compared with the other 2 regimes (19.6%; P<0.0001 vs. Moviprep; P<0.0001 vs. Senna/Citramag). A total of 45.65% of patients reported KleanPrep as tasting unpleasant. This was significantly more than both Moviprep (10.47%; P=0.008) and Senna/Citramag (9.88%; P<0.0001). The overall cleansing efficacy across the 3 groups (those with grades A or B) was 73.9%, 74.5%, and 86.5% for KleanPrep, Moviprep, and Senna/Citramag, respectively. In this series Senna/Citramag proved significantly better at bowel cleansing than KleanPrep (P<0.05) and it showed a trend toward better cleansing when compared with Moviprep (P=0.08). Nonrandomized trial. Split-dosing regime for morning and afternoon lists may have confounded results. In summary, low-volume PEG

  15. Reduced Cathartic Bowel Preparation for CT Colonography: Prospective Comparison of 2-L Polyethylene Glycol and Magnesium Citrate

    PubMed Central

    Keedy, Alexander W.; Aslam, Rizwan; Weinstein, Stefanie; Landeras, Luis A.; Shah, Janak N.; McQuaid, Kenneth R.; Yeh, Benjamin M.

    2011-01-01

    Purpose: To prospectively compare adequacy of colonic cleansing, adequacy of solid stool and fluid tagging, and patient acceptance by using reduced-volume, 2-L polyethylene glycol (PEG) versus magnesium citrate bowel preparations for CT colonography. Materials and Methods: This study was approved by the institutional Committee on Human Research and was compliant with HIPAA; all patients provided written consent. In this randomized, investigator-blinded study, 50 patients underwent oral preparation with either a 2-L PEG or a magnesium citrate solution, tagging with oral contrast agents, and subsequent CT colonography and segmentally unblinded colonoscopy. The residual stool (score 0 [best] to 3 [worst]) and fluid (score 0 [best] to 4 [worst]) burden and tagging adequacy were qualitatively assessed. Residual fluid attenuation was recorded as a quantitative measure of tagging adequacy. Patients completed a tolerance questionnaire within 2 weeks of scanning. Preparations were compared for residual stool and fluid by using generalized estimating equations; the Mann-Whitney test was used to compare the qualitative tagging score, mean residual fluid attenuation, and adverse effects assessed on the patient experience questionnaire. Results: The mean residual stool (0.90 of three) and fluid burden (1.05 of four) scores for PEG were similar to those for magnesium citrate (0.96 [P = .58] and 0.98 [P = .48], respectively). However, the mean fecal and fluid tagging scores were significantly better for PEG (0.48 and 0.28, respectively) than for magnesium citrate (1.52 [P < .01] and 1.28 [P < .01], respectively). Mean residual fluid attenuation was higher for PEG (765 HU) than for magnesium citrate (443 HU, P = .01), and mean interpretation time was shorter for PEG (14.8 minutes) than for magnesium citrate (18.0 minutes, P = .04). Tolerance ratings were not significantly different between preparations. Conclusion: Reduced-volume PEG and magnesium citrate bowel preparations

  16. Zinc phosphate conversion coatings

    DOEpatents

    Sugama, Toshifumi

    1997-01-01

    Zinc phosphate conversion coatings for producing metals which exhibit enhanced corrosion prevention characteristics are prepared by the addition of a transition-metal-compound promoter comprising a manganese, iron, cobalt, nickel, or copper compound and an electrolyte such as polyacrylic acid, polymethacrylic acid, polyitaconic acid and poly-L-glutamic acid to a phosphating solution. These coatings are further improved by the incorporation of Fe ions. Thermal treatment of zinc phosphate coatings to generate .alpha.-phase anhydrous zinc phosphate improves the corrosion prevention qualities of the resulting coated metal.

  17. Yolk-Shell Porous Microspheres of Calcium Phosphate Prepared by Using Calcium L-Lactate and Adenosine 5'-Triphosphate Disodium Salt: Application in Protein/Drug Delivery.

    PubMed

    Ding, Guan-Jun; Zhu, Ying-Jie; Qi, Chao; Sun, Tuan-Wei; Wu, Jin; Chen, Feng

    2015-06-26

    A facile and environmentally friendly approach has been developed to prepare yolk-shell porous microspheres of calcium phosphate by using calcium L-lactate pentahydrate (CL) as the calcium source and adenosine 5'-triphosphate disodium salt (ATP) as the phosphate source through the microwave-assisted hydrothermal method. The effects of the concentration of CL, the microwave hydrothermal temperature, and the time on the morphology and crystal phase of the product are investigated. The possible formation mechanism of yolk-shell porous microspheres of calcium phosphate is proposed. Hemoglobin from bovine red cells (Hb) and ibuprofen (IBU) are used to explore the application potential of yolk-shell porous microspheres of calcium phosphate in protein/drug loading and delivery. The experimental results indicate that the as-prepared yolk-shell porous microspheres of calcium phosphate have relatively high protein/drug loading capacity, sustained protein/drug release, favorable pH-responsive release behavior, and a high biocompatibility in the cytotoxicity test. Therefore, the yolk-shell porous microspheres of calcium phosphate have promising applications in various biomedical fields such as protein/drug delivery. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Zinc phosphate conversion coatings

    DOEpatents

    Sugama, T.

    1997-02-18

    Zinc phosphate conversion coatings for producing metals which exhibit enhanced corrosion prevention characteristics are prepared by the addition of a transition-metal-compound promoter comprising a manganese, iron, cobalt, nickel, or copper compound and an electrolyte such as polyacrylic acid, polymethacrylic acid, polyitaconic acid and poly-L-glutamic acid to a phosphating solution. These coatings are further improved by the incorporation of Fe ions. Thermal treatment of zinc phosphate coatings to generate {alpha}-phase anhydrous zinc phosphate improves the corrosion prevention qualities of the resulting coated metal. 33 figs.

  19. Sphingosine-1-Phosphate Signaling and Metabolism Gene Signature in Pediatric Inflammatory Bowel Disease: A Matched-case Control Pilot Study

    PubMed Central

    Suh, Jung H.; Degagné, Émilie; Gleghorn, Elizabeth E.; Setty, Mala; Rodriguez, Alexis; Park, K. T.; Verstraete, Sofia G.; Heyman, Melvin B.; Patel, Ashish S.; Irek, Melissa; Gildengorin, Ginny L.; Hubbard, Neil E.; Borowsky, Alexander D.; Saba, Julie D.

    2018-01-01

    Goal The aim of this study was to investigate gene expression levels of proteins involved in sphingosine-1-phosphate (S1P) metabolism and signaling in a pediatric inflammatory bowel disease (IBD) patient population. Background IBD is a debilitating disease affecting 0.4% of the US population. The incidence of IBD in childhood is rising. Identifying effective targeted therapies that can be used safely in young patients and developing tools for selecting specific candidates for targeted therapies are important goals. Clinical IBD trials now underway target S1PR1, a receptor for the pro-inflammatory sphingolipid S1P. However, circulating and tissue sphingolipid levels and S1P-related gene expression have not been characterized in pediatric IBD. Methods Pediatric IBD patients and controls were recruited in a four-site study. Patients received a clinical score using PUCAI or PCDAI evaluation. Colon biopsies were collected during endoscopy. Gene expression was measured by qRT-PCR. Plasma and gut tissue sphingolipids were measured by LC-MS/MS. Results Genes of S1P synthesis (SPHK1, SPHK2), degradation (SGPL1), and signaling (S1PR1, S1PR2, and S1PR4) were significantly upregulated in colon biopsies of IBD patients with moderate/severe symptoms compared with controls or patients in remission. Tissue ceramide, dihydroceramide, and ceramide-1-phosphate (C1P) levels were significantly elevated in IBD patients compared with controls. Conclusions A signature of elevated S1P-related gene expression in colon tissues of pediatric IBD patients correlates with active disease and normalizes in remission. Biopsied gut tissue from symptomatic IBD patients contains high levels of pro-apoptotic and pro-inflammatory sphingolipids. A combined analysis of gut tissue sphingolipid profiles with this S1P-related gene signature may be useful for monitoring response to conventional therapy. PMID:29788359

  20. Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging.

    PubMed

    Wei, Wei; Ge, Zhi-Zheng; Lu, Hong; Gao, Yun-Jie; Hu, Yun-Biao; Xiao, Shu-Dong

    2008-01-01

    To evaluate the effects of the various methods of small bowel preparation on the quality of visualization of the small bowel and the gastrointestinal transit time of capsule endoscopy (CE). Ninety patients referred for CE were prospectively randomized to three equal groups according to the preparation used: (a) a control group, in which patients were requested to drink 1 L of clear liquids only, 12 h before the examination; (b) a purgative group, in which patients were requested to ingest 1 L of a polyethylene glycol (PEG)/electrolyte solution only, 12 h before the examination; or (c) a purgative combined with simethicone group (P-S group), in which patients were requested to ingest 1 L of PEG, 12 h before the examination, and 300 mg of simethicone, 20 min before the examination. Effects of the different bowel preparations on the gastric transit time (GTT), small bowel transit time (SBTT), examination completion rate, quality of images of the entire small intestine, and cleansing of the proximal small bowel and distal ileum were evaluated. The number of patients with "adequate" cleansing of the entire small intestine was 17 in the P-S group, 12 in the purgative group, and seven in the control group (P= 0.002). The P-S group had significantly better image quality than the control group (P= 0.001). The P-S group had significantly better image quality for the proximal small bowel (segment A [Seg A]) than the control group (P= 0.0001). Both the P-S group (P= 0.0001) and the purgative group (P= 0.0002) had significantly better image quality for the distal ileum (segment B [Seg B]) than the control group; the P-S group had significantly better image quality than the purgative group as well (P= 0.0121). Gastrointestinal transit time was not different among the three groups, nor was the examination completion rate. Purgative bowel cleansing combined with simethicone before CE improved the quality of imaging of the entire small bowel as well as the visualization of the

  1. Nutritional deficiency during colonoscopy preparation: the forgotten iatrogeny.

    PubMed

    Nunes, Gonçalo; Barata, Ana Teresa; Santos, Carla Adriana; Patita, Marta; Fonseca, Jorge

    2018-05-01

    bowel preparation for colonoscopy induces a semi-fasting state, with a potential negative impact on fragile patients. The present study aims to quantify nutritional deficiency during colonoscopy preparation. this was an observational and cross-sectional study. A convenience sample was obtained that included adults that underwent colonoscopy after bowel preparation with Klean-Prep® according to the center protocol. Anthropometric evaluation was performed and nutritional deficiency was calculated via the quantification of energy and protein intake during the 48 hours prior to the examination which was compared with the individuals' needs. The association between nutritional deficiency with the quality of bowel preparation, age and status (hospitalized/ambulatory) was evaluated. the study included 131 patients aged 21-91 years (mean 63.6 ± 13.2 years); 73 cases were male. Malnutrition reached 67.2% using specific anthropometric tools. A median preparation quality of six points was found when the Boston Bowel Preparation Scale was considered. The mean intake 48 hours prior to the procedure was 1,795 kcal and 100 g of protein. A daily energy intake of less than 50% of the individual needs was observed in 88 patients and less than 25% in 29 cases. The mean energy and protein deficiency were 59% (p < 0.01) and 45% (p < 0.01), and there was no correlation with preparation quality (p > 0.05). Nutritional defiency is similar in hospitalized and ambulatory patients (p > 0.05), but higher in older individuals (p = 0.04). nutritional deficiency during colonoscopy preparation was significant, more so in older patients, and there was no correlation with the quality of bowel preparation. We conclude that bowel preparation regimens should be reformulated with an improved nutritional intake and the inclusion of nutritional supplements without residues.

  2. Efficient preparation of terminal conjugated dienes by coupling of dienol phosphates with grignard reagents under iron catalysis.

    PubMed

    Cahiez, Gérard; Habiak, Vanessa; Gager, Olivier

    2008-06-19

    An efficient new route to prepare stereoselectively terminal conjugated dienes by coupling Grignard reagents and dienol phosphates in the presence of Fe(acac)3 is described. The synthetic utility of this new iron-catalyzed procedure is illustrated by the synthesis of the pheromone of Diparopsis castanea according to a very expeditious strategy.

  3. Bowel Prep Quality in Patients of Low Socioeconomic Status Undergoing Screening Colonoscopy with Patient Navigation

    ERIC Educational Resources Information Center

    Miller, Sarah Johanna; Itzkowitz, Steven H.; Shah, Brijen; Jandorf, Lina

    2016-01-01

    The effectiveness of colonoscopy is directly affected by the quality of the patient's bowel preparation. Patients with lower socioeconomic status (SES) are at increased risk of having suboptimal bowel prep quality. Patient navigators can play a key role in clarifying bowel prep instructions. The aim of the present study was to examine the quality…

  4. Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn's disease patients.

    PubMed

    Papamichael, Konstantinos; Karatzas, Pantelis; Theodoropoulos, Ioannis; Kyriakos, Nikos; Archavlis, Emmanuel; Mantzaris, Gerasimos J

    2015-01-01

    Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn's disease (CD). This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients.

  5. Microwave assisted preparation of magnesium phosphate cement (MPC) for orthopedic applications: a novel solution to the exothermicity problem.

    PubMed

    Zhou, Huan; Agarwal, Anand K; Goel, Vijay K; Bhaduri, Sarit B

    2013-10-01

    There are two interesting features of this paper. First, we report herein a novel microwave assisted technique to prepare phosphate based orthopedic cements, which do not generate any exothermicity during setting. The exothermic reactions during the setting of phosphate cements can cause tissue damage during the administration of injectable compositions and hence a solution to the problem is sought via microwave processing. This solution through microwave exposure is based on a phenomenon that microwave irradiation can remove all water molecules from the alkaline earth phosphate cement paste to temporarily stop the setting reaction while preserving the active precursor phase in the formulation. The setting reaction can be initiated a second time by adding aqueous medium, but without any exothermicity. Second, a special emphasis is placed on using this technique to synthesize magnesium phosphate cements for orthopedic applications with their enhanced mechanical properties and possible uses as drug and protein delivery vehicles. The as-synthesized cements were evaluated for the occurrences of exothermic reactions, setting times, presence of Mg-phosphate phases, compressive strength levels, microstructural features before and after soaking in (simulated body fluid) SBF, and in vitro cytocompatibility responses. The major results show that exposure to microwaves solves the exothermicity problem, while simultaneously improving the mechanical performance of hardened cements and reducing the setting times. As expected, the cements are also found to be cytocompatible. Finally, it is observed that this process can be applied to calcium phosphate cements system (CPCs) as well. Based on the results, this microwave exposure provides a novel technique for the processing of injectable phosphate bone cement compositions. © 2013.

  6. Irritable Bowel Syndrome

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Irritable Bowel Syndrome KidsHealth / For Teens / Irritable Bowel Syndrome What's in ... intestinal disorder called irritable bowel syndrome. What Is Irritable Bowel Syndrome? Irritable bowel syndrome (IBS) is a common intestinal ...

  7. Positive detection of exfoliated colon cancer cells on linear stapler cartridges was associated with depth of tumor invasion and preoperative bowel preparation in colon cancer.

    PubMed

    Ikehara, Kishiko; Endo, Shungo; Kumamoto, Kensuke; Hidaka, Eiji; Ishida, Fumio; Tanaka, Jun-Ichi; Kudo, Shin-Ei

    2016-08-31

    The aim of this study was to investigate exfoliated cancer cells (ECCs) on linear stapler cartridges used for anastomotic sites in colon cancer. We prospectively analyzed ECCs on linear stapler cartridges used for anastomosis in 100 colon cancer patients who underwent colectomy. Having completed the functional end-to-end anastomosis, the linear stapler cartridges were irrigated with saline, which was collected for cytological examination and cytological diagnoses were made by board-certified pathologists based on Papanicolaou staining. The detection rate of ECCs on the linear stapler cartridges was 20 %. Positive detection of ECCs was significantly associated with depth of tumor invasion (p = 0.012) and preoperative bowel preparation (p = 0.003). There were no marked differences between ECC-positive and ECC-negative groups in terms of the operation methods, tumor location, histopathological classification, and surgical margins. Since ECCs were identified on the cartridge of the linear stapler used for anastomosis, preoperative mechanical bowel preparation using polyethylene glycol solution and cleansing at anastomotic sites using tumoricidal agents before anastomosis may be necessary to decrease ECCs in advanced colon cancer.

  8. Bowel incontinence

    MedlinePlus

    Uncontrollable passage of feces; Loss of bowel control; Fecal incontinence; Incontinence - bowel ... older, women tend to have problems with bowel control more often than men. Children who have problems ...

  9. Evidence-based recommendations for bowel cleansing before colonoscopy in children: a report from a national working group.

    PubMed

    Turner, D; Levine, A; Weiss, B; Hirsh, A; Shamir, R; Shaoul, R; Berkowitz, D; Bujanover, Y; Cohen, S; Eshach-Adiv, O; Jamal, Gera; Kori, M; Lerner, A; On, A; Rachman, L; Rosenbach, Y; Shamaly, H; Shteyer, E; Silbermintz, A; Yerushalmi, B

    2010-12-01

    There are no current recommendations for bowel cleansing before colonoscopy in children. The Israeli Society of Pediatric Gastroenterology and Nutrition (ISPGAN) established an iterative working group to formulate evidence-based guidelines for bowel cleansing in children prior to colonoscopy. Data were collected by systematic review of the literature and via a national-based survey of all endoscopy units in Israel. Based on the strength of evidence, the Committee reached consensus on six recommended protocols in children. Guidelines were finalized after an open audit of ISPGAN members. Data on 900 colonoscopies per year were accrued, which represents all annual pediatric colonoscopies performed in Israel. Based on the literature review, the national survey, and the open audit, several age-stratified pediatric cleansing protocols were proposed: two PEG-ELS protocols (polyethylene-glycol with electrolyte solution); Picolax-based protocol (sodium picosulphate with magnesium citrate); sodium phosphate protocol (only in children over the age of 12 years who are at low risk for renal damage); stimulant laxative-based protocol (e. g. bisacodyl); and a PEG 3350-based protocol. A population-based analysis estimated that the acute toxicity rate of oral sodium phosphate is at most 3/7320 colonoscopies (0.041 %). Recommendations on diet and enema use are provided in relation to each proposed protocol. There is no ideal bowel cleansing regimen and, thus, various protocols are in use. We propose several evidence-based protocols to optimize bowel cleansing in children prior to colonoscopy and minimize adverse events. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Preparation, mechanical property and cytocompatibility of freeze-cast porous calcium phosphate ceramics reinforced by phosphate-based glass.

    PubMed

    Yang, Yanqiu; He, Fupo; Ye, Jiandong

    2016-12-01

    In this study, phosphate-based glass (PG) was used as a sintering aid for freeze-cast porous biphasic calcium phosphate (BCP) ceramic, which was sintered under a lower temperature (1000°C). The phase composition, pore structure, compressive strength, and cytocompatibility of calcium phosphate composite ceramics (PG-BCP) were evaluated. The results indicated that PG additive reacted with calcium phosphate during the sintering process, forming β-Ca2P2O7; the ions of sodium and magnesium from PG partially substituted the calcium sites of β-calcium phosphate in BCP. The PG-BCP showed good cytocompatibility. The pore width of the porous PG-BCP ceramics was around 50μm, regardless of the amount of PG sintering aid. As the content of PG increased from 0wt.% to 15wt.%, the compressive strength of PG-BCP increased from 0.02 MP to 0.28MPa. When the PG additive was 17.5wt.%, the compressive strength of PG-BCP dramatically increased to 5.66MPa. Addition of 15wt.% PG was the critical point for the properties of PG-BCP. PG is considered as an effective sintering aid for freeze-cast porous bioceramics. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Small bowel obstruction following perforation of the uterus at induced abortion.

    PubMed

    Nkor, S K; Igberase, G O; Osime, O C; Faleyimu, B L; Babalola, R

    2009-01-01

    Unsafe abortion is an important contributor to maternal morbidity and mortality. To present a case of small bowel obstruction following perforation of the uterus at induced abortion. A 36-year-old woman, presented at a private hospital, with abdominal pain and weight loss. She had full clinical assessment and laboratory investigations which indicated small bowel obstruction following perforation of the uterus at induced abortion, and was commenced on treatment. She was para 5+0. Her main complaints were abdominal and weight loss following induced abortion of a 12- week pregnancy, four months prior to presentation. At presentation the tools (ultrasound scan, plain abdominal radiograph and barium enema) used for diagnoses only suggested some form of intestinal obstruction and were unremarkable. Correct diagnoses indicating small bowel obstruction was only made at laparotomy. An exploratory laparotomy, adhesiolysis, small bowel resection, end to end anastomosis and bowel decompression was done after bowel preparation. Laparotomy has an enviable place in bowel injuries secondary to uterine perforation especially when there is a diagnostic dilemma. Nigerian female population requires continuous health education on widespread and effective use of contraception. Physicians need training and retraining on abortion techniques and management of abortion complications.

  12. Preparation of photocatalytic ZnO nanoparticles and application in photochemical degradation of betamethasone sodium phosphate using taguchi approach

    NASA Astrophysics Data System (ADS)

    Giahi, M.; Farajpour, G.; Taghavi, H.; Shokri, S.

    2014-07-01

    In this study, ZnO nanoparticles were prepared by a sol-gel method for the first time. Taguchi method was used to identify the several factors that may affect degradation percentage of betamethasone sodium phosphate in wastewater in UV/K2S2O8/nano-ZnO system. Our experimental design consisted of testing five factors, i.e., dosage of K2S2O8, concentration of betamethasone sodium phosphate, amount of ZnO, irradiation time and initial pH. With four levels of each factor tested. It was found that, optimum parameters are irradiation time, 180 min; pH 9.0; betamethasone sodium phosphate, 30 mg/L; amount of ZnO, 13 mg; K2S2O8, 1 mM. The percentage contribution of each factor was determined by the analysis of variance (ANOVA). The results showed that irradiation time; pH; amount of ZnO; drug concentration and dosage of K2S2O8 contributed by 46.73, 28.56, 11.56, 6.70, and 6.44%, respectively. Finally, the kinetics process was studied and the photodegradation rate of betamethasone sodium phosphate was found to obey pseudo-first-order kinetics equation represented by the Langmuir-Hinshelwood model.

  13. Chronic methadone use, poor bowel visualization and failed colonoscopy: A preliminary study

    PubMed Central

    Verma, Siddharth; Fogel, Joshua; Beyda, David J; Bernstein, Brett; Notar-Francesco, Vincent; Mohanty, Smruti R

    2012-01-01

    AIM: To examine effects of chronic methadone usage on bowel visualization, preparation, and repeat colonoscopy. METHODS: In-patient colonoscopy reports from October, 2004 to May, 2009 for methadone dependent (MD) patients were retrospectively evaluated and compared to matched opioid naive controls (C). Strict criteria were applied to exclude patients with risk factors known to cause constipation or gastric dysmotility. Colonoscopy reports of all eligible patients were analyzed for degree of bowel visualization, assessment of bowel preparation (good, fair, or poor), and whether a repeat colonoscopy was required. Bowel visualization was scored on a 4 point scale based on multiple prior studies: excellent = 1, good = 2, fair = 3, or poor = 4. Analysis of variance (ANOVA) and Pearson χ2 test were used for data analyses. Subgroup analysis included correlation between methadone dose and colonoscopy outcomes. All variables significantly differing between MD and C groups were included in both univariate and multivariate logistic regression analyses. P values were two sided, and < 0.05 were considered statistically significant. RESULTS: After applying exclusionary criteria, a total of 178 MD patients and 115 C patients underwent a colonoscopy during the designated study period. A total of 67 colonoscopy reports for MD patients and 72 for C were included for data analysis. Age and gender matched controls were randomly selected from this population to serve as controls in a numerically comparable group. The average age for MD patients was 52.2 ± 9.2 years (range: 32-72 years) years compared to 54.6 ± 15.5 years (range: 20-81 years) for C (P = 0.27). Sixty nine percent of patients in MD and 65% in C group were males (P = 0.67). When evaluating colonoscopy reports for bowel visualization, MD patients had significantly greater percentage of solid stool (i.e., poor visualization) compared to C (40.3% vs 6.9%, P < 0.001). Poor bowel preparation (35.8% vs 9.7%, P < 0.001) and

  14. Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients

    PubMed Central

    Papamichael, Konstantinos; Karatzas, Pantelis; Theodoropoulos, Ioannis; Kyriakos, Nikos; Archavlis, Emmanuel; Mantzaris, Gerasimos J.

    2015-01-01

    Background Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn’s disease (CD). Methods This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. Results Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. Conclusion Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients. PMID:26423317

  15. Same-day colonoscopy preparation with Senna alkaloids and bisacodyl tablets: A pilot study

    PubMed Central

    Yenidogan, Erdinc; Okan, Ismail; Kayaoglu, Huseyin Ayhan; Akgul, Gokhan Giray; Sansal, Mufit; Tali, Servet; Ozsoy, Zeki; Sahin, Mustafa

    2014-01-01

    AIM: To evaluate the efficacy of same-day bowel preparation with Senna alkaloids combined with bisacodyl tablets in routine colonoscopy procedures. METHODS: Between March and June 2013, a same-day bowel preparation was implemented in our endoscopy unit. The preparation consisted of a semi-liquid, fiber-free diet one day prior to the procedure, with two bisacodyl tablets after lunch and dinner, and 250 mL of Senna alkaloid with 1.5 L of drinking water at 6 am the day of the procedure. The quality control parameters of colonoscopy were evaluated and implemented according to the guidelines of the American Society for Gastrointestinal Endoscopy. The pre-procedure, during-procedure and post-procedure patient data were collected and analyzed: (1) pre-procedure (age, gender, comorbid diseases, colonoscopy indications, complete lack of compliance with the bowel preparation protocol); (2) during-procedure (sedation dose, duration of colonoscopy, withdrawal time, cecal intubation rate, polyp detection rate, Boston Bowel Preparation Scores and presence of foam and clear liquid); and (3) post-procedure (visual analogue scale score, pain during the procedure, patient satisfaction and premature withdrawal due to the insufficient bowel preparation). RESULTS: A total of 75 patients were included in this study with a mean age of 54.64 ± 13.29 years; 53.3% (40/75) were female and 46.7% (35/75) were male. A complete lack of compliance with the bowel preparation protocol was seen in 6.7% of patients (5/75). The mean total duration of colonoscopy was 16.12 ± 6.51 min, and the mean withdrawal time was 8.89 ± 4.07 min. The cecal intubation rate was 93.8% (61/64) and the polyp detection rate was 40% (30/75). The mean Boston Bowel Preparation Score was 7.38 ± 1.81, with the following distribution: right colon, 2.34 ± 0.89; transverse colon, 2.52 ± 0.67; left colon, 2.52 ± 0.63. The mean visual analogue scale score was 4.59 ± 1.57. Due to insufficient bowel preparation, seven

  16. Same-day colonoscopy preparation with Senna alkaloids and bisacodyl tablets: a pilot study.

    PubMed

    Yenidogan, Erdinc; Okan, Ismail; Kayaoglu, Huseyin Ayhan; Akgul, Gokhan Giray; Sansal, Mufit; Tali, Servet; Ozsoy, Zeki; Sahin, Mustafa

    2014-11-07

    To evaluate the efficacy of same-day bowel preparation with Senna alkaloids combined with bisacodyl tablets in routine colonoscopy procedures. Between March and June 2013, a same-day bowel preparation was implemented in our endoscopy unit. The preparation consisted of a semi-liquid, fiber-free diet one day prior to the procedure, with two bisacodyl tablets after lunch and dinner, and 250 mL of Senna alkaloid with 1.5 L of drinking water at 6 am the day of the procedure. The quality control parameters of colonoscopy were evaluated and implemented according to the guidelines of the American Society for Gastrointestinal Endoscopy. The pre-procedure, during-procedure and post-procedure patient data were collected and analyzed: (1) pre-procedure (age, gender, comorbid diseases, colonoscopy indications, complete lack of compliance with the bowel preparation protocol); (2) during-procedure (sedation dose, duration of colonoscopy, withdrawal time, cecal intubation rate, polyp detection rate, Boston Bowel Preparation Scores and presence of foam and clear liquid); and (3) post-procedure (visual analogue scale score, pain during the procedure, patient satisfaction and premature withdrawal due to the insufficient bowel preparation). A total of 75 patients were included in this study with a mean age of 54.64 ± 13.29 years; 53.3% (40/75) were female and 46.7% (35/75) were male. A complete lack of compliance with the bowel preparation protocol was seen in 6.7% of patients (5/75). The mean total duration of colonoscopy was 16.12 ± 6.51 min, and the mean withdrawal time was 8.89 ± 4.07 min. The cecal intubation rate was 93.8% (61/64) and the polyp detection rate was 40% (30/75). The mean Boston Bowel Preparation Score was 7.38 ± 1.81, with the following distribution: right colon, 2.34 ± 0.89; transverse colon, 2.52 ± 0.67; left colon, 2.52 ± 0.63. The mean visual analogue scale score was 4.59 ± 1.57. Due to insufficient bowel preparation, seven patients (7/75; 9.3%) were

  17. Small bowel dilation in children with short bowel syndrome is associated with mucosal damage, bowel-derived bloodstream infections, and hepatic injury.

    PubMed

    Hukkinen, Maria; Mutanen, Annika; Pakarinen, Mikko P

    2017-09-01

    Liver disease occurs frequently in short bowel syndrome. Whether small bowel dilation in short bowel syndrome could influence the risk of liver injury through increased bacterial translocation remains unknown. Our aim was to analyze associations between small bowel dilation, mucosal damage, bloodstream infections, and liver injury in short bowel syndrome patients. Among short bowel syndrome children (n = 50), maximal small bowel diameter was measured in contrast series and expressed as the ratio to the height of the fifth lumbar vertebra (small bowel diameter ratio), and correlated retrospectively to fecal calprotectin and plasma citrulline-respective markers of mucosal inflammation and mass-bloodstream infections, liver biochemistry, and liver histology. Patients with pathologic small bowel diameter ratio >2.17 had increased fecal calprotectin and decreased citrulline (P < .04 each). Of 33 bloodstream infections observed during treatment with parenteral nutrition, 16 were caused by intestinal bacteria, cultured 15 times more frequently when small bowel diameter ratio was >2.17 (P < .001). Intestinal bloodstream infections were predicted by small bowel diameter ratio (odds ratio 1.88, P = .017), and their frequency decreased after operative tapering procedures (P = .041). Plasma bilirubin concentration, gamma-glutamyl transferase activity, and histologic grade of cholestasis correlated with small bowel diameter ratio (0.356-0.534, P < .014 each), and were greater in the presence of intestinal bloodstream infections (P < .001 for all). Bloodstream infections associated with portal inflammation, cholestasis, and fibrosis grades (P < .031 for each). In linear regression, histologic cholestasis was predicted by intestinal bloodstream infections, small bowel diameter ratio, and parenteral nutrition (β = 0.36-1.29; P < .014 each), while portal inflammation by intestinal bloodstream infections only (β = 0.62; P = .033). In children with short bowel

  18. Predictors of patient reluctance to wake early in the morning for bowel preparation for colonoscopy: a precolonoscopy survey in city-wide practice.

    PubMed

    Shafer, L A; Walker, J R; Waldman, C; Michaud, V; Yang, C; Bernstein, C N; Hathout, L; Park, J; Sisler, J; Wittmeier, K; Restall, G; Singh, H

    2018-06-01

     Many endoscopists do not use split-dose bowel preparation (SDBP) for morning colonoscopies. Despite SDBP being recommended practice, they believe patients will not agree to take early morning bowel preparation (BP). We assessed patients' opinions about waking early for BP.  A self-administered survey was distributed between 08/2015 and 06/2016 to patients in Winnipeg, Canada when they attended an outpatient colonoscopy. Logistic regression was performed to determine predictors of reluctance to use early morning BP.  Of the 1336 respondents (52 % female, median age 57 years), 33 % had used SDBP for their current colonoscopy. Of the 1336, 49 % were willing, 24 % neutral, and 27 % reluctant to do early morning BP. Predictors of reluctant versus willing were number of prior colonoscopies (OR 1.20; 95 %CI: 1.07 - 1.35), female gender (OR 1.65; 95 %CI: 1.19 - 2.29), unclear BP information (OR 1.86; 95 %CI: 1.21 - 2.85), high BP anxiety (OR 2.02; 95 %CI: 1.35 - 3.02), purpose of current colonoscopy being bowel symptoms (OR 1.40; 95 %CI: 1.00 - 1.97), use of 4 L of polyethylene glycol laxative (OR 1.45; 95 %CI: 1.02 - 2.06), not having SDBP (OR 1.96; 95 %CI: 1.31 - 2.93), and not having finished the laxative for the current colonoscopy (OR 1.66; 95 %CI: 1.01 - 2.73). Most of the same predictors were identified when reluctance was compared to willing or neutral, and in ordinal logistic regression.  Almost three-quarters of patients do not express reluctance to get up early for BP. Among those who are reluctant, improving BP information, allaying BP-related anxiety, and use of low volume BP may increase acceptance of SDBP.

  19. Predictors of patient reluctance to wake early in the morning for bowel preparation for colonoscopy: a precolonoscopy survey in city-wide practice

    PubMed Central

    Shafer, L. A.; Walker, J. R.; Waldman, C.; Michaud, V.; Yang, C.; Bernstein, C. N.; Hathout, L.; Park, J.; Sisler, J.; Wittmeier, K.; Restall, G.; Singh, H.

    2018-01-01

    Introduction  Many endoscopists do not use split-dose bowel preparation (SDBP) for morning colonoscopies. Despite SDBP being recommended practice, they believe patients will not agree to take early morning bowel preparation (BP). We assessed patients’ opinions about waking early for BP. Methods  A self-administered survey was distributed between 08/2015 and 06/2016 to patients in Winnipeg, Canada when they attended an outpatient colonoscopy. Logistic regression was performed to determine predictors of reluctance to use early morning BP. Results  Of the 1336 respondents (52 % female, median age 57 years), 33 % had used SDBP for their current colonoscopy. Of the 1336, 49 % were willing, 24 % neutral, and 27 % reluctant to do early morning BP. Predictors of reluctant versus willing were number of prior colonoscopies (OR 1.20; 95 %CI: 1.07 – 1.35), female gender (OR 1.65; 95 %CI: 1.19 – 2.29), unclear BP information (OR 1.86; 95 %CI: 1.21 – 2.85), high BP anxiety (OR 2.02; 95 %CI: 1.35 – 3.02), purpose of current colonoscopy being bowel symptoms (OR 1.40; 95 %CI: 1.00 – 1.97), use of 4 L of polyethylene glycol laxative (OR 1.45; 95 %CI: 1.02 – 2.06), not having SDBP (OR 1.96; 95 %CI: 1.31 – 2.93), and not having finished the laxative for the current colonoscopy (OR 1.66; 95 %CI: 1.01 – 2.73). Most of the same predictors were identified when reluctance was compared to willing or neutral, and in ordinal logistic regression. Conclusions  Almost three-quarters of patients do not express reluctance to get up early for BP. Among those who are reluctant, improving BP information, allaying BP-related anxiety, and use of low volume BP may increase acceptance of SDBP. PMID:29854940

  20. Preparation and characterization of TiO2 and Si-doped octacalcium phosphate composite coatings on zirconia ceramics (Y-TZP) for dental implant applications

    NASA Astrophysics Data System (ADS)

    Bao, Lei; Liu, Jingxiao; Shi, Fei; Jiang, Yanyan; Liu, Guishan

    2014-01-01

    In order to prevent the low temperature degradation and improve the bioactivity of zirconia ceramic implants, TiO2 and Si-doped octacalcium phosphate composite coating was prepared on zirconia substrate. The preventive effect on low temperature degradation and surface morphology of the TiO2 layer were studied. Meanwhile, the structure and property changes of the bioactive coating after doping Si were discussed. The results indicate that the dense TiO2 layer, in spite of some microcracks, inhibited the direct contact of the water vapor with the sample's surface and thus prevented the low temperature degradation of zirconia substrates. The acceleration aging test shows that the ratio of the monoclinic phase transition decreased from 10% for the original zirconia substrate to 4% for the TiO2-coated substrate. As to the Si-doped octacalcium phosphate coating prepared by biomimetic method, the main phase composition of the coating was octacalcium phosphate. The morphology of the coating was lamellar-like, and the surface was uniform and continuous with no cracks being observed. It is suggested that Si was added into the coating both through substituting for PO43- and doping as NaSiO3.

  1. The Preparation, Characterization and Formation Mechanism of a Calcium Phosphate Conversion Coating on Magnesium Alloy AZ91D.

    PubMed

    Liu, Dong; Li, Yanyan; Zhou, Yong; Ding, Yigang

    2018-05-28

    The poor corrosion resistance of magnesium alloys is one of the main obstacles preventing their widespread usage. Due to the advantages of lower cost and simplicity in operation, chemical conversion coating has drawn considerable attention for its improvement of the corrosion resistance of magnesium alloys. In this study, a calcium phosphate coating was prepared on magnesium alloy AZ91D by chemical conversion. For the calcium phosphate coating, the effect of processing parameters on the microstructure and corrosion resistance was studied by scanning electron microscope (SEM) and electrochemical methods, and the coating composition was characterized by X-ray diffraction (XRD). The calcium phosphate coating was mainly composed of CaHPO₄·2H₂O (DCPD), with fewer cracks and pores. The coating with the leaf-like microstructure provided great corrosion resistance to the AZ91D substrate, and was obtained under the following conditions: 20 min, ambient temperature, and no stirring. At the same time, the role of NH₄H₂PO₄ as the coating-forming agent and the acidifying agent in the conversion process was realized, and the formation mechanism of DCPD was discussed in detail in this work.

  2. International bowel function basic spinal cord injury data set.

    PubMed

    Krogh, K; Perkash, I; Stiens, S A; Biering-Sørensen, F

    2009-03-01

    International expert working group. To develop an International Bowel Function Basic Spinal Cord Injury (SCI) Data Set presenting a standardized format for the collection and reporting of a minimal amount of information on bowel function in daily practice or in research. Working group consisting of members appointed by the American Spinal Injury Association (ASIA) and the International Spinal Cord Society (ISCoS). A draft prepared by the working group was reviewed by Executive Committee of the International SCI Standards and Data Sets, and later by ISCoS Scientific Committee and the ASIA Board. Relevant and interested scientific and professional (international) organizations and societies (approximately 40) were also invited to review the data set and it was posted on the ISCoS and ASIA websites for 3 months to allow comments and suggestions. The ISCoS Scientific Committee, Council and ASIA Board received the data set for final review and approval. The International Bowel Function Basic SCI Data Set includes the following 12 items: date of data collection, gastrointestinal or anal sphincter dysfunction unrelated to SCI, surgical procedures on the gastrointestinal tract, awareness of the need to defecate, defecation method and bowel care procedures, average time required for defecation, frequency of defecation, frequency of fecal incontinence, need to wear pad or plug, medication affecting bowel function/constipating agents, oral laxatives and perianal problems. An International Bowel Function Basic SCI Data Set has been developed.

  3. Synthesis of methylene- and difluoromethylenephosphonate analogues of uridine-4-phosphate and 3-deazauridine-4-phosphate.

    PubMed

    Taylor, Scott D; Mirzaei, Farzad; Sharifi, Ali; Bearne, Stephen L

    2006-12-08

    Cytidine triphosphate synthetase (CTPS) catalyzes the formation of cytidine triphosphate from glutamine, uridine-5'-triphosphate (UTP), and adenosine-5'-triphosphate. Inhibitors of CTPS are of interest because of their potential as therapeutic agents. One approach to potent enzyme inhibitors is to use analogues of high energy intermediates formed during the reaction. The CTPS reaction proceeds via the high energy intermediate UTP-4-phosphate (UTP-4-P). Four novel analogues of uridine-4-phosphate (U-4-P) and 3-deazauridine-4-phosphate (3-deazaU-4-P) were synthesized in which the labile phosphate ester oxygen was replaced with a methylene and difluoromethylene group. The methylene analogue of U-4-P, compound 1, was prepared by a reaction of the sodium salt of tert-butyl diethylphosphonoacetate with protected, 4-O-activated uridine followed by acetate deprotection and decarboxylation. It was found that this compound undergoes relatively facile dephosphonylation presumably via a metaphosphate intermediate. The difluoromethylene derivative, compound 2, was prepared by electrophilic fluorination of protected 1. This compound was stable and did not undergo dephosphonylation. Synthesis of the methylene analogue of 3-deazaU-4-P, compound 3, was achieved by ribosylation of protected 4-(phosphonomethyl)-2-hydroxypyridine. Electrophilic fluorination was also employed in the preparation of protected 4-(phosphonodifluoromethyl)-2-hydroxypyridine which was used as the key building block in the synthesis of difluoro derivative 4. These compounds represent the first examples of a nucleoside in which the base has been chemically modified with a methylene or difluormethylenephosphonate group.

  4. Phosphate glasses for radioactive, hazardous and mixed waste immobilization

    DOEpatents

    Cao, H.; Adams, J.W.; Kalb, P.D.

    1998-11-24

    Lead-free phosphate glass compositions are provided which can be used to immobilize low level and/or high level radioactive wastes in monolithic waste forms. The glass composition may also be used without waste contained therein. Lead-free phosphate glass compositions prepared at about 900 C include mixtures from about 1--6 mole % iron (III) oxide, from about 1--6 mole % aluminum oxide, from about 15--20 mole % sodium oxide or potassium oxide, and from about 30--60 mole % phosphate. The invention also provides phosphate, lead-free glass ceramic glass compositions which are prepared from about 400 C to about 450 C and which includes from about 3--6 mole % sodium oxide, from about 20--50 mole % tin oxide, from about 30--70 mole % phosphate, from about 3--6 mole % aluminum oxide, from about 3--8 mole % silicon oxide, from about 0.5--2 mole % iron (III) oxide and from about 3--6 mole % potassium oxide. Method of making lead-free phosphate glasses are also provided. 8 figs.

  5. Serious events in older Ontario residents receiving bowel preparations for outpatient colonoscopy with various comorbidity profiles: A descriptive, population-based study

    PubMed Central

    Ho, Joanne M; Gruneir, Andrea; Fischer, Hadas D; Fu, Longdi; Lipscombe, Lorraine L; Bell, Chaim M; Cavalcanti, Rodrigo B; Anderson, Geoffrey M; Rochon, Paula A

    2012-01-01

    BACKGROUND: Polyethylene glycol-based bowel preparations (PEGBPs) and sodium picosulfate (NaPS) are commonly used for bowel cleansing before colonoscopy. Little is known about adverse events associated with these preparations, particularly in older patients or patients with medical comorbidities. OBJECTIVE: To characterize the incidence of serious events following outpatient colonoscopy in patients using PEGBPs or NaPS. METHODS: The present population-based retrospective cohort study examined data from Ontario health care databases between April 1, 2005 and December 31, 2007, including patients ≥66 years of age who received either PEGBP or NaPS for an outpatient colonoscopy. Patients with cardiac or renal disease, long-term care residents or patients receiving concurrent diuretic therapy were identified as high risk for adverse events. The primary outcome was a serious event (SE) defined as a composite of nonelective hospitalization, emergency department visit or death within seven days of the colonoscopy. RESULTS: Of the 50,660 outpatients ≥66 years of age who underwent a colonoscopy, SEs were observed in 675 (2.4%) and 543 (2.4%) patients in the PEGBP and NaPS groups, respectively. Among high-risk patients (n=30,168), SEs occurred in 481 (2.8%) and 367 (2.8%) of patients receiving PEGBP and NaPS, respectively. CONCLUSIONS: The SE rate within seven days of outpatient colonoscopy was 24 per 1000 procedures, and among high-risk patients was 28 per 1000 procedures. The rates were similar for PEGBP and NaPS. Clinicians should be aware of the risks associated with colonoscopy in older patients with comorbidities. PMID:22803018

  6. Bowel urgency in patients with irritable bowel syndrome.

    PubMed

    Basilisco, Guido; De Marco, Elisabetta; Tomba, Carolina; Cesana, Bruno Mario

    2007-01-01

    Bowel urgency is the most bothersome symptom in irritable bowel syndrome patients with diarrhea, but its pathophysiology is poorly understood. Our aim was to assess the relationships among reporting the symptom, the reservoir functions of the colon and rectum, and the patients' psychologic profile. The study involved 28 consecutive patients with irritable bowel syndrome and 17 healthy subjects. The presence or absence of bowel urgency was verified by means of a questionnaire during the 3 days required for the ingestion of radio-opaque markers. On the fourth day, an abdominal x-ray was taken to assess colonic transit time, and rectal sensory and motor responses were measured during rectal distention. The subjects' psychologic profiles were assessed using a psychologic symptoms checklist. Forty-six percent of the patients reported urgency associated with at least 1 defecation. The multivariate logistic regression analysis showed that colonic transit was the only variable independently associated with reported bowel urgency, but the threshold for the sensation of urgency was not removed from the model since its borderline significance level. Rectal compliance was closely associated with the threshold for the sensation of urgency during rectal distention but was not an independent factor for reporting the sensation. The patients with and without urgency showed altered psychologic profiles. The symptom of urgency is associated with objective alterations in the colonic and rectal reservoir of patients with irritable bowel syndrome.

  7. Evaluation of bowel distension and bowel wall visualization according to patient positions during administration of oral contrast media for CT enterography.

    PubMed

    Lee, Seul Bi; Kim, Seung Ho; Son, Jung Hee; Baik, Ji Yeon

    2017-12-01

    To compare small bowel distension and bowel wall visualization among three different patients' positions (supine, sitting and right decubitus) during administration of oral contrast media in preparation for CT enterography (CTE). A total of 150 consecutive patients (104 males and 46 females; mean age 34.6 years, range 15-78 years) who were scheduled to undergo CTE were recruited. Patients were randomly allocated into the three position groups during oral contrast media administration, and there were 50 patients in each group. Two blinded radiologists independently scored the luminal distension and visualization of the bowel wall using a continuous 5-point scale (1: worst and 5: best) at the jejunum and ileum. The Mann-Whitney U test was used to evaluate differences between any two groups among the three positions for bowel distension and wall visualization. For ileal distension, the supine and sitting positions performed better than the right decubitus position [for reader 1, mean: 3.4/3.2/2.9 (hereafter, supine/sitting/right decubitus in order), p = 0.002/0.033; for reader 2, 3.3/3.0/2.6, p < 0.001/0.027]. However, there was no significant difference among the three groups for jejunal distension (for reader 1, 2.4/2.3/2.2; for reader 2, 2.4/2.4/2.2, p > 0.05, respectively). For bowel wall visualization, the supine and sitting positions were superior to the right decubitus position for the ileum when scored by one reader (4.0/3.8/3.4, p = 0.001/0.015). Supine and sitting positions during the administration of oral contrast media provided better ileal distension than the right decubitus position in obtaining CTE. Advances in knowledge: The performance of CTE largely depends on adequate luminal distension and wall visualization. As the terminal ileum is the predominant site of small bowel pathology for inflammatory bowel disease, the supine or sitting position would be preferable for patients who are suspected of having small bowel pathology.

  8. Mg- and Zn-modified calcium phosphates prepared by biomimetic precipitation and subsequent treatment at high temperature.

    PubMed

    Rabadjieva, D; Tepavitcharova, S; Gergulova, R; Sezanova, K; Titorenkova, R; Petrov, O; Dyulgerova, E

    2011-10-01

    Powders of magnesium-modified as well as zinc-modified calcium phosphates (Me-β-TCP and HA) with a (Ca(2+)+Mg(2+)+Zn(2+)+Na(+)+K(+))/P ratio of 1.3-1.4 and various Me(2+)/(Me(2+)+Ca(2+)) ratios (from 0.005 to 0.16) were prepared in biomimetic electrolyte systems at pH 8, mother liquid maturation and further syntering at 600-1000°C. Some differences in zinc and magnesium modifications have been prognosed on the basis of thermodynamic modeling of the studied systems and explained by the Mg(2+) and Zn(2+) ion chemical behaviour. The temperature as well as the degree of Zn(2+) and Mg(2+) ions substitutions were found to stabilize the β-TCP structure and this effect was more prononced for zinc. Thus, zinc-modified β-TCP powders consisting of idiomorphic crystals were obtained through sintering of Zn(2+) ion substituted calcium phosphates precursors at 800-1000°C. The Mg(2+) ion substitution leads to obtaining magnesium-modified β-TCP with spherical grains.

  9. High-output stoma after small-bowel resections for Crohn's disease.

    PubMed

    Tsao, Stephen K K; Baker, Melanie; Nightingale, Jeremy M D

    2005-12-01

    A 56-year-old Caucasian woman with a history of Crohn's disease and multiple bowel resections resulting in a loop jejunostomy was referred to our Nutritional Unit from a neighboring district general hospital for further management. She was first seen in October 2001, and initial assessment indicated that she was malnourished with fluid depletion, evidenced by the high volume of stomal fluid produced. There had been no sudden change in her medication, her Crohn's disease was quiescent and there was no evidence of any intra-abdominal sepsis. Despite a high calorific intake through her diet, she continued to lose weight. Serum urea and electrolytes; magnesium; C-reactive protein; full blood count; urinary spot sodium; anthropometric measurements. High-output stoma with malabsorption as a consequence of repeated small-bowel surgery. The patient was treated with oral hypotonic fluid restriction (0.5 l/day), 2 l of oral glucose-saline solution per day, high-dose oral antimotility agents (loperamide and codeine phosphate), a proton-pump inhibitor (omeprazole) and oral magnesium replacement. A year later, the patient's loop jejunostomy was closed and an end ileostomy fashioned, bringing an additional 35 cm of small bowel into continuity; macronutrient absorption improved but her problem of dehydration was only slightly reduced. She was stabilized on a twice-weekly subcutaneous magnesium and saline infusion and daily oral 1alpha-hydroxycholecalciferol.

  10. Novel Targeted Therapies for Inflammatory Bowel Disease.

    PubMed

    Coskun, Mehmet; Vermeire, Severine; Nielsen, Ole Haagen

    2017-02-01

    Our growing understanding of the immunopathogenesis of inflammatory bowel disease (IBD) has opened new avenues for developing targeted therapies. These advances in treatment options targeting different mechanisms of action offer new hope for personalized management. In this review we highlight emerging novel and easily administered therapeutics that may be viable candidates for the management of IBD, such as antibodies against interleukin 6 (IL-6) and IL-12/23, small molecules including Janus kinase inhibitors, antisense oligonucleotide against SMAD7 mRNA, and inhibitors of leukocyte trafficking to intestinal sites of inflammation (e.g., sphingosine 1-phosphate receptor modulators). We also provide an update on the current status in clinical development of these new classes of therapeutics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Large bowel resection

    MedlinePlus

    ... blockage in the intestine due to scar tissue Colon cancer Diverticular disease (disease of the large bowel) Other reasons for bowel resection are: Familial polyposis (polyps are growths on the lining of the colon or rectum) Injuries that damage the large bowel ...

  12. Chemically durable phosphate glasses and a method for their preparation

    DOEpatents

    Day, D.E.; Wilder, J.A. Jr.

    The chemical durability of alkali phosphate glasses is improved by incorporation of up to 23 weight percent of nitrogen. A typical phosphate glass contains: 10 to 60 mole % of Li/sub 2/O, Na/sub 2/O or K/sub 2/O; 5 to 40 mole % of BaO or CaO; 0 to 1 to 10 mole % of Al/sub 2/O/sub 3/; and 40 to 70 mole % of P/sub 2/O/sub 5/. Nitrides, such as AlN, are the favored additives.

  13. Novel selenium containing boro-phosphate glasses: preparation and structural study.

    PubMed

    Ciceo-Lucacel, R; Radu, T; Ponta, O; Simon, V

    2014-06-01

    We synthesized a new boro-phosphate glass system with different %mol SeO2 content by conventional melt quenching technique. All samples were obtained in a glassy state with the vitreous structure confirmed by X-ray diffraction analysis. Scanning electron microscopy (SEM) revealed some non-homogeneous domains on the glasses surface, and their tendency to link each other once the selenium oxide content increases. Energy-dispersive X-ray analysis (EDAX) indicated similar elemental composition in different regions of each sample. X-ray photoelectron spectroscopy (XPS) was used to determine the nature of chemical bonding and the elemental composition at the sample surfaces, and Fourier transform infrared (FT-IR) spectroscopy was used to determine the structural groups in the obtained glass structure. Based on FT-IR results, the glass structure at short range order consists mainly of small phosphate units such as pyrophosphate (i.e. P2O7(4-) dimmers or terminating groups at the end of phosphate chains) and some metaphosphate (i.e. PO3(-) middle groups in the phosphate chains) units. The boron atoms are mainly placed in three-coordinated sites in BØ3 or BØ2O(-) units. A small contribution of BØ4(-) units was also detected from the FT-IR spectra of glasses. For SeO2 content higher than 5mol%, the modifier role of selenium ions is strongly reflected on the local structure dominated in this case by pyrophosphate units. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Bowel Prep Quality in Patients of Low Socioeconomic Status Undergoing Screening Colonoscopy With Patient Navigation.

    PubMed

    Miller, Sarah Johanna; Itzkowitz, Steven H; Shah, Brijen; Jandorf, Lina

    2016-10-01

    The effectiveness of colonoscopy is directly affected by the quality of the patient's bowel preparation. Patients with lower socioeconomic status (SES) are at increased risk of having suboptimal bowel prep quality. Patient navigators can play a key role in clarifying bowel prep instructions. The aim of the present study was to examine the quality of bowel prep and its predictors among individuals of low SES undergoing screening colonoscopy with patient navigation. Participants (N = 607) were individuals of low SES who completed a screening colonoscopy with patient navigation. Demographic information was collected after the participants received a primary care referral for a screening colonoscopy. After the colonoscopy was completed, medical charts were reviewed to document the colonoscopists' bowel prep quality ratings. A total of 6.8% (41/607) of the sample had poor bowel prep, which significantly correlated with having a colonoscopy that did not reach the cecum. If fair preps were included, approximately 19.3% (117/607) of our cohort would be considered to have suboptimal bowel prep. Our suboptimal bowel prep rates were better than those reported from other low SES samples. © 2015 Society for Public Health Education.

  15. Can a tailored knowledge translation strategy improve short term outcomes? A pilot study to increase compliance with bowel preparation recommendations in general surgery.

    PubMed

    Eskicioglu, Cagla; Gagliardi, Anna; Fenech, Darlene S; Victor, Charles J; McLeod, Robin S

    2011-07-01

    Previous studies have shown that practices supported by level I evidence may take up to 20 years before they are adopted. Although mechanical bowel preparation (MBP) has been a routine practice in colorectal surgery, there is strong evidence dating back to the early 1990s suggesting that in most patients MBP before elective colorectal surgery is not required. The objective of this study was to determine if surgical practices pertaining to bowel preparation could be altered using a tailored knowledge translation strategy. A multi-faceted strategy including guideline development, consensus, education by opinion leaders, audit and feedback, and reminder cards was used in this before-after study. The primary outcome was compliance with the recommendations presented in the guideline regarding MBP, normal diet on the day prior to surgery, and enemas. Two-hundred eighty-two patients were enrolled in the study with 111 enrolled before the intervention and 171 enrolled after the intervention. Demographic and clinical characteristics between the 2 groups were similar. Overall, there was a 7.8% increase in compliance with MBP recommendations (81.1% vs 88.4%, P = .038), a 10.2% increase in compliance with diet recommendations (45.6% vs 55.8%, P = .080), and a 5.6% increase in compliance with enema recommendations (88.5% vs 94.2%, P < .001). The results of this study reveal that a tailored, multi-faceted knowledge translation strategy is effective in changing surgeon behavior. Copyright © 2011 Mosby, Inc. All rights reserved.

  16. The effectiveness of simethicone in improving visibility during colonoscopy.

    PubMed

    Park, Jae Jun; Lee, Sang Kil; Jang, Jae Young; Kim, Hyo Jong; Kim, Nam Hoon

    2009-01-01

    In colonoscopy examination, luminal visibility is frequently limited due to intraluminal bubbles. In present study was evaluated factors affecting bubble formation and the effects of simethicone in preventing bubble formation during colonoscopy. Consecutive patients (n=164) who received polyethylene glycol or sodium phosphate for bowel preparation were prospectively enrolled. Before colonoscopy, 57 patients took 80 mg simethicone after ingestion of bowel preparation solution and 107 did not to determine whether simethicone decreased bubble formation. Intraluminal gas bubbles were assessed and graded as follows: 0, minimal or none; 1, covering less than half the lumen; 2, covering at least half the lumen or the entire circumference. Grade 2 bubbles were regarded as significant, limiting visibility. Sodium phosphate preparation tended to have more bubbles than the polyethylene glycol. Significant bubbles were more likely to occur in males than females (p = 0.020). Significant bubbles were noted in 34.6% of patients without simethicone and 7% of patients with simethicone. Simethicone significantly lowered the incidence of bubbles during colonoscopy when given after a preparation solution (p < 0.05), The present study findings indicate that taking simethicone after an oral polyethylene glycol or sodium phosphate preparation can improve colonic visibility by diminishing colonic bubbles.

  17. A case of osteomalacia due to deranged mineral balance caused by saccharated ferric oxide and short-bowel syndrome

    PubMed Central

    Nomoto, Hiroshi; Miyoshi, Hideaki; Nakamura, Akinobu; Nagai, So; Kitao, Naoyuki; Shimizu, Chikara; Atsumi, Tatsuya

    2017-01-01

    Abstract Rationale: Saccharated ferric oxide has been shown to lead to elevation of fibroblast growth factor 23, hypophosphatemia, and, consequently, osteomalacia. Moreover, mineral imbalance is often observed in patients with short-bowel syndrome to some degree. Patient concerns: A 62-year-old woman with short-bowel syndrome related with multiple resections of small intestines due to Crohn disease received regular intravenous administration of saccharated ferric oxide. Over the course of treatment, she was diagnosed with tetany, which was attributed to hypocalcemia. Additional assessments of the patient revealed not only hypocalcemia, but also hypophosphatemia, hypomagnesemia, osteomalacia, and a high concentration of fibroblast growth factor 23 (314 pg/mL). Diagnoses: We diagnosed her with mineral imbalance-induced osteomalacia due to saccharated ferric oxide and short-bowel syndrome. Interventions: Magnesium replacement therapy and discontinuation of saccharated ferric oxide alone. Outcomes: These treatments were able to normalize her serum mineral levels and increase her bone mineral density. Lessons: This case suggests that adequate evaluation of serum minerals, including phosphate and magnesium, during saccharated ferric oxide administration may be necessary, especially in patients with short-bowel syndrome. PMID:28953654

  18. Silane surface modification effects on the electromagnetic properties of phosphatized iron-based SMCs

    NASA Astrophysics Data System (ADS)

    Fan, Liang-Fang; Hsiang, Hsing-I.; Hung, Jia-Jing

    2018-03-01

    It is difficult to achieve homogeneous phosphatized iron powder dispersion in organic resins during the preparation of soft magnetic composites (SMCs). Inhomogeneous iron powder mixing in organic resins generally leads to the formation of micro-structural defects in SMCs and hence causes the magnetic properties to become worse. Phosphatized iron powder dispersion in organic resins can be improved by coating the phosphatized iron powder surfaces with a coupling agent. This study investigated the (3-aminopropyl) triethoxysilane (APTES) surface modification effects on the electromagnetic properties of phosphatized iron-based soft magnetic composites (SMCs). The results showed that the phosphatized iron powder surface can be modified using APTES to improve the phosphatized iron powder and epoxy resin compatibility and hence enhance phosphate iron powder epoxy mixing. The tensile strength, initial permeability, rated current under DC-bias superposition and magnetic loss in SMCs prepared using phosphatized iron powders can be effectively improved using APTES surface modification, which provides a promising candidate for power chip inductor applications.

  19. Bowel Movement

    MedlinePlus

    A bowel movement is the last stop in the movement of food through your digestive tract. Your stool passes out of ... what you eat and drink. Sometimes a bowel movement isn't normal. Diarrhea happens when stool passes ...

  20. Recovery of phosphate from aqueous solution by magnesium oxide decorated magnetic biochar and its potential as phosphate-based fertilizer substitute.

    PubMed

    Li, Ronghua; Wang, Jim J; Zhou, Baoyue; Awasthi, Mukesh Kumar; Ali, Amjad; Zhang, Zengqiang; Lahori, Altaf Hussain; Mahar, Amanullah

    2016-09-01

    The present study deals with the preparation of a novel MgO-impregnated magnetic biochar (MMSB) for phosphate recovery from aqueous solution. The MMSB was evaluated against sugarcane harvest residue biochar (SB) and magnetic biochar without Mg (MSB). The results showed that increasing Mg content in MMSB greatly improved the phosphate adsorption compared to SB and MSB, with 20% Mg-impregnated MMSB (20MMSB) recovering more than 99.5% phosphate from aqueous solution. Phosphate adsorption capacity of 20MMSB was 121.25mgP/g at pH 4 and only 37.53% of recovered phosphate was desorbed by 0.01mol/L HCl solutions. XRD and FTIR analysis showed that phosphate sorption mechanisms involved predominately with surface electrostatic attraction and precipitation with impregnated MgO and surface inner-sphere complexation with Fe oxide. The 20MMSB exhibited both maximum phosphate sorption and strong magnetic separation ability. Overall, phosphate-loaded 20MMSB significantly enhanced plant growth and could be used as a potential substitute for phosphate-based fertilizer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. An unusual white blood cell scan in a child with inflammatory bowel disease: a case report.

    PubMed

    Porn, U; Howman-Giles, R; O'Loughlin, E; Uren, R; Chaitow, J

    2000-10-01

    Technetium-99m-labeled leukocyte (WBC) imaging is a valuable screening method for inflammatory bowel disease, especially in children, because of its high rate of sensitivity, low cost, and ease of preparation. A 14-year-old girl is described who had juvenile arthritis and iritis complicated by inflammatory bowel disease. She was examined for recurrent abdominal pain. A Tc-99m stannous colloid WBC scan was performed, and tracer accumulation was seen in the small bowel in the region of the distal ileum on the initial 1-hour image. Delayed imaging at 3 hours also revealed tracer accumulation in the cecum and ascending colon, which was not seen on the early image. A biopsy of the colon during endoscopy showed no evidence of active inflammation in the colon. The small bowel was not seen. Computed tomography revealed changes suggestive of inflammatory bowel disease in the distal ileum. The appearance on the WBC study was most likely a result of inflammatory bowel disease involving the distal ileum, with transit of luminal activity into the large bowel.

  2. Improving of bowel cleansing effect for polyethylene glycol with ascorbic acid using simethicone

    PubMed Central

    Yoo, In Kyung; Jeen, Yoon Tae; Kang, Seung Hun; Lee, Jae Hyung; Kim, Seung Han; Lee, Jae Min; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Chun, Hoon Jai; Lee, Hong Sik; Kim, Chang Duck

    2016-01-01

    Abstract Background and Aim: Low-volume polyethylene glycol with ascorbic acid (PEG-Asc) use is reported to be as safe and effective as traditional 4-L polyethylene glycol use. However, PEG-Asc produces bubbles, which cause problems during colonoscopy. Data on the effects of using antifoaming agents such as simethicone with PEG-Asc are lacking. The aim of this CONSORT-prospective, randomized, observer-blinded, controlled trial is to compare the quality of bowel preparation and compliance between PEG-Asc users and PEG-Asc plus simethicone users. Methods: Adult outpatients aged 18 to 80 years undergoing colonoscopy were recruited to the study. Two hundred sixty patients were randomly assigned to 1 of 2 treatment arms, PEG-Asc or PEG-Asc plus simethicone. The primary outcome measure was the bowel cleansing quality using Boston bowel preparation scale and bubble scores. The secondary outcome measures were patient tolerability and doctor tolerability. Results: The simethicone group showed superior cleansing results (6–9 Boston scale scores: 99% vs. 84%, <5% bubble scores: 96% vs. 49%, P < 0.001) and fewer gastrointestinal symptoms (abdominal fullness: 24% vs. 55%, colicky pain: 5% vs. 24%, P < 0.001) than the non-simethicone group. Moreover, endoscopist fatigue during colonoscopy was lower in the simethicone group than in the non-simethicone group (1.31 ± 0.75 vs. 2.97 ± 2.14, P < 0.001). Conclusion: PEG-Asc plus simethicone use was more effective and associated with better patient and endoscopist tolerance than PEG-Asc use. Therefore, this combination is recommended as one of the promising methods for bowel preparation before colonoscopy. PMID:27428209

  3. A case of osteomalacia due to deranged mineral balance caused by saccharated ferric oxide and short-bowel syndrome: A case report.

    PubMed

    Nomoto, Hiroshi; Miyoshi, Hideaki; Nakamura, Akinobu; Nagai, So; Kitao, Naoyuki; Shimizu, Chikara; Atsumi, Tatsuya

    2017-09-01

    Saccharated ferric oxide has been shown to lead to elevation of fibroblast growth factor 23, hypophosphatemia, and, consequently, osteomalacia. Moreover, mineral imbalance is often observed in patients with short-bowel syndrome to some degree. A 62-year-old woman with short-bowel syndrome related with multiple resections of small intestines due to Crohn disease received regular intravenous administration of saccharated ferric oxide. Over the course of treatment, she was diagnosed with tetany, which was attributed to hypocalcemia. Additional assessments of the patient revealed not only hypocalcemia, but also hypophosphatemia, hypomagnesemia, osteomalacia, and a high concentration of fibroblast growth factor 23 (314 pg/mL). We diagnosed her with mineral imbalance-induced osteomalacia due to saccharated ferric oxide and short-bowel syndrome. Magnesium replacement therapy and discontinuation of saccharated ferric oxide alone. These treatments were able to normalize her serum mineral levels and increase her bone mineral density. This case suggests that adequate evaluation of serum minerals, including phosphate and magnesium, during saccharated ferric oxide administration may be necessary, especially in patients with short-bowel syndrome.

  4. Phosphate glasses for radioactive, hazardous and mixed waste immobilization

    DOEpatents

    Cao, H.; Adams, J.W.; Kalb, P.D.

    1999-03-09

    Lead-free phosphate glass compositions are provided which can be used to immobilize low level and/or high level radioactive wastes in monolithic waste forms. The glass composition may also be used without waste contained therein. Lead-free phosphate glass compositions prepared at about 900 C include mixtures from about 1 mole % to about 6 mole % iron (III) oxide, from about 1 mole % to about 6 mole % aluminum oxide, from about 15 mole % to about 20 mole % sodium oxide or potassium oxide, and from about 30 mole % to about 60 mole % phosphate. The invention also provides phosphate, lead-free glass ceramic glass compositions which are prepared from about 400 C to about 450 C and which includes from about 3 mole % to about 6 mole % sodium oxide, from about 20 mole % to about 50 mole % tin oxide, from about 30 mole % to about 70 mole % phosphate, from about 3 mole % to about 6 mole % aluminum oxide, from about 3 mole % to about 8 mole % silicon oxide, from about 0.5 mole % to about 2 mole % iron (III) oxide and from about 3 mole % to about 6 mole % potassium oxide. Method of making lead-free phosphate glasses are also provided. 8 figs.

  5. Phosphate glasses for radioactive, hazardous and mixed waste immobilization

    DOEpatents

    Cao, Hui; Adams, Jay W.; Kalb, Paul D.

    1998-11-24

    Lead-free phosphate glass compositions are provided which can be used to immobilize low level and/or high level radioactive wastes in monolithic waste forms. The glass composition may also be used without waste contained therein. Lead-free phosphate glass compositions prepared at about 900.degree. C. include mixtures from about 1 mole % to about 6 mole % iron (III) oxide, from about 1 mole % to about 6 mole % aluminum oxide, from about 15 mole % to about 20 mole % sodium oxide or potassium oxide, and from about 30 mole % to about 60 mole % phosphate. The invention also provides phosphate, lead-free glass ceramic glass compositions which are prepared from about 400.degree. C. to about 450.degree. C. and which includes from about 3 mole % to about 6 mole % sodium oxide, from about 20 mole % to about 50 mole % tin oxide, from about 30 mole % to about 70 mole % phosphate, from about 3 mole % to about 6 mole % aluminum oxide, from about 3 mole % to about 8 mole % silicon oxide, from about 0.5 mole % to about 2 mole % iron (III) oxide and from about 3 mole % to about 6 mole % potassium oxide. Method of making lead-free phosphate glasses are also provided.

  6. Phosphate glasses for radioactive, hazardous and mixed waste immobilization

    DOEpatents

    Cao, Hui; Adams, Jay W.; Kalb, Paul D.

    1999-03-09

    Lead-free phosphate glass compositions are provided which can be used to immobilize low level and/or high level radioactive wastes in monolithic waste forms. The glass composition may also be used without waste contained therein. Lead-free phosphate glass compositions prepared at about 900.degree. C. include mixtures from about 1 mole % to about 6 mole %.iron (III) oxide, from about 1 mole % to about 6 mole % aluminum oxide, from about 15 mole % to about 20 mole % sodium oxide or potassium oxide, and from about 30 mole % to about 60 mole % phosphate. The invention also provides phosphate, lead-free glass ceramic glass compositions which are prepared from about 400.degree. C. to about 450.degree. C. and which includes from about 3 mole % to about 6 mole % sodium oxide, from about 20 mole % to about 50 mole % tin oxide, from about 30 mole % to about 70 mole % phosphate, from about 3 mole % to about 6 mole % aluminum oxide, from about 3 mole % to about 8 mole % silicon oxide, from about 0.5 mole % to about 2 mole % iron (III) oxide and from about 3 mole % to about 6 mole % potassium oxide. Method of making lead-free phosphate glasses are also provided.

  7. Irritable bowel syndrome.

    PubMed

    Malone, Michael A

    2011-09-01

    Irritable bowel syndrome (IBS) is a common gastrointestinal disorder that leads to crampy pain, gassiness, bloating, and changes in bowel habits in the absence of any currently identifiable organic disorder. Patients with IBS may be classified by their predominant bowel habit: diarrhea-predominant, constipation-predominant, or IBS with alternating bowel movements. IBS is often associated with stress or anxiety. Although IBS can be frustrating and concerning to patients with this disorder, it does not cause permanent harm to the intestines and does not lead to a serious disease such as cancer. Although treatments exist for its symptoms, there is no known cure. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Rifaximin - Chitosan Nanoparticles for Inflammatory Bowel Disease (IBD).

    PubMed

    Kumar, Jatinder; Newton, Amaldoss M J

    2017-01-01

    Inflammatory Bowel Disease (IBD) cannot be controlled easily and the recurrence is the most challenging issue for the physicians. There are various controlled and colon targeted drug delivery systems available for the treatment with limited success rate. Nanoparticles prepared by using the colon targeted polymers such as chitosan may improve the IBD due to their smaller size, unique physico chemical properties and targeting potential. The aim of this investigation was designed to formulate and develop a colon targeted polysaccharide nanoparticles of rifaximin (RFX) by using linear polysaccharide chitosan, for the improvement of rifaximin solubility, overall therapeutic efficacy and colon targeting. The research was focused on developing RFX nanoparticles for the treatment of Inflammatory Bowel Disease (IBD) by ionic gelation method. Nanoparticles were subjected to various characterization techniques such as XRD, FTIR and mean particle size (MPS) by Master Sizer and Zeta Sizer. Transmission Electron Microscopy (TEM), drug entrapment efficiency and zeta potential are also determined for the developed formulations. The efficiency of drug release from prepared formulation was studied in vitro by using a dialysis bag diffusion technique in the buffer condition mimicking stomach, intestine and colonic pH conditions. The prepared nanoparticles demonstrated the size in the nano range. The drug release profile was controlled in the upper GI tract and the maximum amount of drug was released in the colonic conditions. The prepared nanoparticles significantly improved the solubility of rifaximin. The zeta potential of the best chitosan preparation was found to be 37.79, which confirms the stability of prepared nanosuspension. Nanoparticles with small particle size found to have high encapsulation efficiency and relatively high loading capacity and predetermined in vitro release profile. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Pumpable/injectable phosphate-bonded ceramics

    DOEpatents

    Singh, Dileep; Wagh, Arun S.; Perry, Lamar; Jeong, Seung-Young

    2001-01-01

    A pumpable ceramic composition is provided comprising an inorganic oxide, potassium phosphate, and an oxide coating material. Also provided is a method for preparing pumpable ceramic-based waste forms comprising selecting inorganic oxides based on solubility, surface area and morphology criteria; mixing the selected oxides with phosphate solution and waste to form a first mixture; combining an additive to the first mixture to create a second mixture; adding water to the second mixture to create a reactive mixture; homogenizing the reactive mixture; and allowing the reactive mixture to cure.

  10. [Volvulus of the small bowel due to ascaris lumbricoides package: about a case].

    PubMed

    Diouf, Cheikh; Kane, Ahmed; Ndoye, Ndeye Aby; Ndour, Oumar; Faye-Fall, Aimé Lakh; Fall, Mbaye; Alumeti, Désiré Munyali; Ngom, Gabriel

    2016-01-01

    We report an exceptional case of a 7 year-old patient with necrotic small bowel volvulus due to adult ascaris lumbricoides. At the admission, the child had intestinal obstruction evolving since two days with alteration of general state. Abdominal radiography without preparation showed small bowel air-fluid levels and tiger-stripe appearance evoking the diagnosis of acute intestinal obstruction associated with abdominal mass. After resuscitation, the surgical treatment consisted of laparotomy which showed necrotic volvulus of the terminal ileum containing adult ascaris lumbricoides. The patient underwent small bowel resection, approximately one meter of affected section was removed and then an ileostomy was performed. The evolution was favorable. The patient underwent ileorectal anastomosis four weeks later. After a 2 year follow-up period the child had no symptoms.

  11. Endoscopic Therapy in Crohn's Disease: Principle, Preparation, and Technique.

    PubMed

    Chen, Min; Shen, Bo

    2015-09-01

    Stricture and fistula are common complications of Crohn's disease. Endoscopic balloon dilation and needle-knife stricturotomy has become a valid treatment option for Crohn's disease-associated strictures. Endoscopic therapy is also increasingly used in Crohn's disease-associated fistula. Preprocedural preparations, including routine laboratory testing, imaging examination, anticoagulant management, bowel cleansing and proper sedation, are essential to ensure a successful and safe endoscopic therapy. Adverse events, such as perforation and excessive bleeding, may occur during endoscopic intervention. The endoscopist should be well trained, always be cautious, anticipate for possible procedure-associated complications, be prepared for damage control during endoscopy, and have surgical backup ready. In this review, we discuss the principle, preparation, techniques of endoscopic therapy, as well as the prevention and management of endoscopic procedure-associated complications. We propose that inflammatory bowel disease endoscopy may be a part of training for "super" gastroenterology fellows, i.e., those seeking a career in advanced endoscopy or in inflammatory bowel disease.

  12. [Portuguese Consensus on the Diagnosis, Prevention and Treatment of Anaemia in Inflammatory Bowel Disease].

    PubMed

    Magro, Fernando; Ramos, Jaime; Correia, Luís; Lago, Paula; Peixe, Paula; Gonçalves, Ana Rita; Rodrigues, Ãngela; Vieira, Catarina; Ferreira, Daniela; Pereira Silva, João; Túlio, Maria Ana; Salgueiro, Paulo; Fernandes, Samuel

    2016-02-01

    Anaemia can be considered the most common extra-intestinal manifestation in inflammatory bowel disease. Nevertheless, anaemia is often under-diagnosed and under-treated both in adults and children with inflammatory bowel disease. Herein, we report the consensus statements on the management of anaemia in inflammatory bowel disease developed by the Portuguese Working Group on Inflammatory Bowel Disease (known as Grupo de Estudo da Doença Inflamatória Intestinal - GEDII) to aid clinicians in daily management of inflammatory bowel disease patients. A comprehensive literature review was conducted in order to prepare consensus statements on the following topics: (1) prevalence and diagnosis of anaemia in inflammatory bowel disease, (2) iron supplementation for the prevention of anaemia in inflammatory bowel disease and (3) treatment of anaemia in inflammatory bowel disease. The final statements for each topic were discussed at a consensus meeting and rated according to the Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence. It was concluded that anaemia has a high incidence and prevalence in inflammatory bowel disease, particularly in those with active disease and hospitalised. Patients with anaemia had decreased quality of life and frequently complained of fatigue. Absolute indications for intravenous therapy should be considered: (1) moderate to severe anaemia (haemoglobin < 10.5 g/dL) or clearly symptomatic anaemia; (2) previous intolerance to oral iron supplements; (3) inappropriate response to oral iron; (4) active severe intestinal disease; (5) need for a quick therapeutic response (e.g. surgery in the short term); (6) concomitant therapy with erythropoiesis-stimulating agent; and (7) patient's preference.

  13. A new colonic lavage system to prepare the colon for colonoscopy: a retrospective study.

    PubMed

    Ziv, Y; Scapa, E

    2013-02-01

    One of the most unpleasant and sometimes difficult elements of colonoscopic examination is the bowel preparation which is usually performed 6 or more hours prior to the examination ("early" preparation), causing many patients to refrain from undergoing this procedure. We present a novel technique for bowel preparation that begins approximately 30 min prior to the introduction of the colonoscope and eliminates the need for significant pre-procedure preparation. The medical records of all consecutive patients who underwent colonoscopy without "early" preparation (CWEP) from May 2009 through June 2010 were retrospectively reviewed. The procedure was performed using a novel cleansing device, the "ColonoScoPrep™", with which the colon is prepared about half an hour prior to insertion of the colonoscope. The only medication required is two to three bisacodyl tablets the night before. The quality of bowel preparation was graded as excellent, good, satisfactory, or poor, and patient satisfaction was assessed according to a prospective protocol. During this period, 125 patients underwent CWEP. Of these, 110 (89.4 %) patients had an excellent or good preparation, permitting complete colonoscopic examination unimpeded by fecal matter. In 11 patients, preparation was satisfactory, in 2 it was poor and in 2, colonoscopy was not completed due to unsatisfactory preparation. None of the patients suffered from abdominal pain or cramps during or after the CWEP and none had post-colonoscopy diarrhea. All patients were satisfied with the procedure. Despite the fact that the study is retrospective, CWEP appears safe and easy to perform. A prospective study comparing conventional bowel preparation and CWEP is now underway.

  14. Effect of humic acid preloading on phosphate adsorption onto zirconium-modified zeolite.

    PubMed

    Lin, Jianwei; Zhang, Zhe; Zhan, Yanhui

    2017-05-01

    A zirconium-modified zeolite (ZrMZ) was prepared, and then, humic acid (HA) was immobilized on the ZrMZ surface to prepare HA-loaded ZrMZ (HA-ZrMZ). The obtained ZrMZ and HA-ZrMZ were characterized by energy dispersive X-ray spectroscopy, elemental analyzer, N 2 adsorption/desorption isotherms, pH at the point of zero charge, and X-ray photoelectron spectroscopy. The adsorption characteristics of phosphate on ZrMZ and HA-ZrMZ were comparatively investigated in batch mode. The adsorption mechanism of phosphate on ZrMZ and HA-ZrMZ was investigated by ionic strength effect and 31 P nuclear magnetic resonance. The mechanism for phosphate adsorption onto ZrMZ was the formation of inner-sphere phosphate complexes at the solid/solution interface. The preloading of HA on ZrMZ reduced the phosphate adsorption capacity, and the more the HA loading amount, the lower the phosphate adsorption capacity. However, the preloading of HA on ZrMZ did not change the phosphate adsorption mechanism; i.e., the formation of inner-sphere phosphate surface complexes was still responsible for the adsorption of phosphate on HA-ZrMZ. The decreased phosphate adsorption capacity for ZrMZ after HA coating could be attributed to the fact that the coating of HA on ZrMZ reduced the amount of binding active sites available for phosphate adsorption, changed the adsorbent surface charges, and reduced the specific surface areas and pore volumes of ZrMZ.

  15. Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial.

    PubMed

    Zhang, Shenghong; Zheng, Danping; Wang, Jinping; Wu, Jianwei; Lei, Pingguang; Luo, Qi; Wang, Liping; Zhang, Beiping; Wang, Hong; Cui, Yi; Chen, Minhu

    2018-04-01

     For bowel preparation, using a reduced volume of polyethylene glycol (PEG) solution without influencing its effectiveness would be preferable. While simethicone shows great potential as an adjunctive agent, data on its use are limited. We aimed to clarify whether simethicone added to low-volume PEG solution improved bowel cleansing. PATIENTS AND METHODS : Consecutive adult patients registered for colonoscopy were recruited from seven medical centers in South China between 15 April and 15 July 2015 and prospectively randomized into two groups: 2 L PEG (conventional group) and 2 L PEG plus simethicone (simethicone group). The primary endpoint was the effectiveness of bowel cleansing according to the Boston Bowel Preparation Scale (BBPS). Secondary endpoints included cecal intubation time, adenoma detection rate (ADR), patient safety and compliance, and adverse events. RESULTS : We included 290 and 289 patients in the conventional and simethicone groups, respectively, for analysis. The proportion with acceptable bowel cleansing (BBPS ≥ 6) was significantly higher in the simethicone group than in the conventional group (88.2 % vs. 76.6 %; P  < 0.001). The mean (SD) BBPS score was significantly lower in the conventional group (6.5 [1.8] vs. 7.3 [1.7]; P  < 0.001), as was the bubble score (2.5 [0.7] vs. 2.8 [0.5]; P  < 0.001). The average cecal intubation time was significantly shorter in the simethicone group (6.3 [3.1] vs. 7.5 [5.1] minutes; P  < 0.001). The ADR in the right colon was higher in the simethicone group than in the conventional group (16.6 % vs. 10.3 %; P  = 0.03). Safety and compliance, including the taste, smell, and dosage of PEG, were similar for both groups.  Simethicone added to low-volume PEG solution improves bowel-cleansing efficacy, with similar safety and compliance, shorter cecal intubation time, and higher ADR. © Georg Thieme Verlag KG Stuttgart · New York.

  16. A randomized, controlled, double-blind trial of the adjunct use of Clebopride in polyethylene glycol electrolyte (PEG) solution for colonoscopy preparation.

    PubMed

    Abdullah, Murdani; Rani, A Aziz; Fauzi, Achmad; Syam, Ari Fahrial; Makmun, Dadang; Simadibrata, Marcellus; Manan, Chudahman; Harjodisastro, Daldiyono

    2010-01-01

    To study the benefit of Clebopride as an adjuvant in polyethylene glycol electrolyte (PEG) solution for colonoscopy preparation. Eighty one adult patients who underwent colonoscopy examination were recruited in this randomized double blind controlled study. First group received PEG and placebo, whereas second group received PEG and Clebopride. Two litres of PEG was taken at night before colonoscopy. The acceptability and tolerability of bowel preparation were assessed through interview method. The efficacy of bowel preparation was assessed using Aronchick's Criteria. In terms of acceptability, 64 patients (31 patients from placebo group vs 33 patients from Clebopride group) were able to drink two litres of PEG solution. Sixty patients (29 patients from placebo group and 31 patients from Clebopride group) were willing to accept PEG solution for their next bowel preparation. On the term of tolerability, nausea, abdominal distension, and borborygmus were more frequent in the placebo group (34.2% vs 27.9%; 44.7% vs 32.6%; 26.3% vs 4.6% respectively). However, only the difference at the incidence of borborygmus that was statistically significant (p<0.05). On the terms of efficacy, both groups showed a comparable bowel preparation quality with 88.4% of bowel preparation in Clebopride group and 81.6% of bowel preparation in placebo group were optimal (p = 0.585). The adjunct use of Clebopride in PEG solution for colonoscopy preparations tends to increase the acceptability, tolerability, and efficacy. The presence of borborygmus was significantly lower in the Clebopride group.

  17. Oral purgative and simethicone before small bowel capsule endoscopy

    PubMed Central

    Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José

    2013-01-01

    AIM: To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. METHODS: Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. RESULTS: There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered

  18. Oral purgative and simethicone before small bowel capsule endoscopy.

    PubMed

    Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José

    2013-02-16

    To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel

  19. Pediatric Inflammatory Bowel Disease.

    PubMed

    Kapoor, Akshay; Bhatia, Vidyut; Sibal, Anupam

    2016-11-15

    The incidence of inflammatory bowel disease is increasing in the pediatric population worldwide. There is paucity of high quality scientific data regarding pediatric inflammatory bowel disease. Most of the guidelines are offshoots of work done in adults, which have been adapted over time to diagnose and treat pediatric patients. This is in part related to the small numbers in pediatric inflammatory bowel disease and less extensive collaboration for multicentric trials both nationally and internationally. A literature search was performed using electronic databases i.e. Pubmed and OVID, using keywords: pediatric, inflammatory bowel disease, Crohns disease, Ulcerative colitis, epidemiology and guidelines. This article amalgamates the broad principles of diagnosing and managing a child with suspected inflammatory bowel disease. 25% of the patients with inflammatory bowel disease are children and and young adolescents. The primary concern is its impact on growth velocity, puberty and quality of life, including psychosocial issues. Treatment guidelines are being re-defined as the drug armamentarium is increasing. The emphasis will be to achieve mucosal healing and normal growth velocity with minimal drug toxicity.

  20. Novel treatments for inflammatory bowel disease

    PubMed Central

    Lee, Hyo Sun; Park, Soo-Kyung; Park, Dong Il

    2018-01-01

    Increased understanding of the immunopathology of inflammatory bowel disease (IBD) has led to the development of targeted therapies and has unlocked a new era in IBD treatment. The development of treatment options aimed at a variety of pathological mechanisms offers new hope for customized therapies. Beyond anti-tumor necrosis factor agents, selective lymphocyte trafficking inhibitors have been proposed as potent drugs for IBD. Among these, vedolizumab has recently been approved for both Crohn’s disease and ulcerative colitis. Numerous other agents for IBD treatment are currently under investigation, including Janus kinase inhibitors, anti-mucosal vascular addressin cell adhesion molecule-1 agents, an anti-SMAD7 antisense oligonucleotide, an anti-interleukin-12/23 monoclonal antibody, and a sphingosine-1-phosphate receptor-1 selective agonist. These agents will likely expand the treatment options available for the management of IBD patients in the future. In this review, we discuss the efficacy and safety of novel agents currently under investigation in IBD clinical trials. PMID:29223139

  1. Partial reactions of d-glucose 6-phosphate–1 l-myoinositol 1-phosphate cyclase

    PubMed Central

    Barnett, J. E. G.; Rasheed, A.; Corina, D. L.

    1973-01-01

    After removal of tightly bound NAD+ by using charcoal, a preparation of d-glucose 6-phosphate–1 l-myoinositol 1-phosphate cyclase catalysed the reduction of 5-keto-d-glucitol 6-phosphate and 5-keto-d-glucose 6-phosphate by [4-3H]NADH to give [5-3H]-glucitol 6-phosphate and [5-3H]glucose 6-phosphate respectively. The position of the tritium atom in the latter was shown by degradation. Both enzyme-catalysed reductions were strongly inhibited by 2-deoxy-d-glucose 6-phosphate, a powerful competitive inhibitor of inositol cyclase. The charcoal-treated enzyme preparation also converted 5-keto-d-glucose 6-phosphate into [3H]myoinositol 1-phosphate in the presence of [4-3H]NADH, but less effectively. These partial reactions of inositol cyclase are interpreted as providing strong evidence for the formation of 5-keto-d-glucose 6-phosphate as an enzyme-bound intermediate in the conversion of d-glucose 6-phosphate into 1 l-myoinositol 1-phosphate. The enzyme was partially inactivated by NaBH4 in the presence of NAD+. Glucose 6-phosphate did not increase the inactivation, and there was no inactivation in the absence of NAD+. There was no evidence for Schiff base formation during the cyclization. d-Glucitol 6-phosphate (l-sorbitol 1-phosphate) was a good inhibitor of the overall reaction. It did not inactivate the enzyme. The apparent molecular weight of inositol cyclase as determined by Sephadex chromatography was 2.15×105. PMID:4352864

  2. Effects of a proprietary Bacillus coagulans preparation on symptoms of diarrhea-predominant irritable bowel syndrome.

    PubMed

    Dolin, B J

    2009-12-01

    Symptoms of irritable bowel syndrome (IBS) have a profound impact on quality of life for many patients and current treatments are sometimes unsatisfactory. This controlled pilot study was conducted to evaluate effects of the proprietary GanedenBC(30) (Bacillus coagulans GBI-30, 6086) probiotic on IBS symptoms, in a randomized, double-blind, placebo-controlled clinical trial including patients with diarrhea-predominant IBS (IBS-D). Patients were randomized to receive either B. coagulans GBI-30, 6086 or placebo once a day for 8 weeks. Patients filled out a quality-of-life questionnaire, and self-assessment diaries were provided to record stool count and consistency, symptom severity, and medication consumption. Of the 61 patients enrolled, six did not meet the inclusion criteria and three were lost to follow-up. Of the remaining 52 patients with IBS-D, the average number of bowel movements per day was significantly reduced for patients treated with B. coagulans GBI-30, 6086 when compared to placebo (P = 0.042). Large variability in baseline scores prevented the assessment of severity scores and quality of life. This small pilot study provides evidence that the proprietary B. coagulans GBI-30, 6086 probiotic is safe and effective for reducing daily bowel movements in patients with IBS-D. Copyright 2009 Prous Science, S.A.U. or its licensors. All rights reserved.

  3. Irritable Bowel Syndrome

    MedlinePlus

    Irritable bowel syndrome (IBS) is a problem that affects the large intestine. It can cause abdominal cramping, bloating, and a change in bowel ... go back and forth between the two. Although IBS can cause a great deal of discomfort, it ...

  4. Magnesium-phosphate-glass cements with ceramic-type properties

    DOEpatents

    Sugama, T.; Kukacka, L.E.

    1982-09-23

    Rapid setting magnesium phosphate (Mg glass) cementitious materials consisting of magnesium phosphate cement paste, polyborax and water-saturated aggregate, exhibits rapid setting and high early strength characteristics. The magnesium glass cement is prepared from a cation-leachable powder and a bivalent metallic ion-accepting liquid such as an aqueous solution of diammonium phosphate and ammonium polyphosphate. The cation-leachable powder includes a mixture of two different magnesium oxide powders processed and sized differently which when mixed with the bivalent metallic ion-accepting liquid provides the magnesium glass cement consisting primarily of magnesium ortho phosphate tetrahydrate, with magnesium hydroxide and magnesium ammonium phosphate hexahydrate also present. The polyborax serves as a set-retarder. The resulting magnesium mono- and polyphosphate cements are particularly suitable for use as a cementing matrix in rapid repair systems for deteriorated concrete structures as well as construction materials and surface coatings for fireproof structures.

  5. Magnesium phosphate glass cements with ceramic-type properties

    DOEpatents

    Sugama, Toshifumi; Kukacka, Lawrence E.

    1984-03-13

    Rapid setting magnesium phosphate (Mg glass) cementitious materials consisting of magnesium phosphate cement paste, polyborax and water-saturated aggregate exhibiting rapid setting and high early strength characteristics. The magnesium glass cement is prepared from a cation-leachable powder and a bivalent metallic ion-accepting liquid such as an aqueous solution of diammonium phosphate and ammonium polyphosphate. The cation-leachable powder includes a mixture of two different magnesium oxide powders processed and sized differently which when mixed with the bivalent metallic ion-accepting liquid provides the magnesium glass cement consisting primarily of magnesium ortho phosphate tetrahydrate, with magnesium hydroxide and magnesium ammonium phosphate hexahydrate also present. The polyborax serves as a set-retarder. The resulting magnesium mono- and polyphosphate cements are particularly suitable for use as a cementing matrix in rapid repair systems for deteriorated concrete structures as well as construction materials and surface coatings for fireproof structures.

  6. Effect of tetracalcium phosphate/monetite toothpaste on dentin remineralization and tubule occlusion in vitro.

    PubMed

    Medvecky, L; Stulajterova, R; Giretova, M; Mincik, J; Vojtko, M; Balko, J; Briancin, J

    2018-03-01

    To investigate the tubule occlusion and remineralization potential of a novel toothpaste with active tetracalcium phosphate/monetite mixtures under de/remineralization cycling. Dentin de/remineralization cycling protocol consisted of demineralization in 1% citric acid at pH 4.6 with following remineralization with toothpastes and soaking in artificial saliva. Effectiveness of toothpastes to promote remineralization was evaluated by measurement of microhardness recovery, analysis of surface roughness, thickness of coating and scanning electron microscopy. The novel tetracalcium phosphate/monetite dentifrice had comparable remineralization potential as commercial calcium silicate/phosphate (SENSODYNE ® ) and magnesium aluminum silicate (Colgate ® ) toothpastes and significantly higher than control saliva (p<0.02). Surface roughness was significantly lower after treatment with prepared and SENSODYNE ® dentifirice (p<0.05). The coatings on dentin surfaces was significantly thicker after applying toothpastes as compared to negative control (p<0.001). The new fluoride toothpaste formulation with bioactive tetracalcium phosphate/monetite calcium phosphate mixture effectively occluded dentin tubules and showed good dentin remineralization potential under de/remineralization cycling. It could replace professional powder preparation based on this mixture. It was demonstrated that prepared dentifrice had comparable properties with commercial fluoride calcium silicate/phosphate or magnesium aluminum silicate dentifrices. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. Single-dose lubiprostone along with split-dose PEG solution without dietary restrictions for bowel cleansing prior to colonoscopy: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Stengel, Joel Z; Jones, David P

    2008-09-01

    Proper colonic cleansing prior to colonoscopy is paramount to ensuring complete mucosal visualization and polyp identification. In a double-blind fashion, we compared single-dose lubiprostone (24 microg) versus placebo pretreatment prior to a split-dose polyethylene glycol electrolyte (PEG-E) bowel preparation without dietary restriction to determine the efficacy, safety, and patient tolerability. Two hundred patients referred for outpatient colorectal cancer screening were randomized to receive a single-dose of unlabeled lubiprostone (24 microg) or placebo prior to a split-dose PEG-E bowel preparation without dietary restriction. The patients were surveyed prior to the colonoscopy on the tolerability of the bowel preparation, and any adverse events were recorded. The cleanliness of the colon was graded by the endoscopist during the procedure utilizing the Ottawa bowel preparation scale. One hundred ninety-one patients completed the study (95%). Split-dose PEG-E with lubiprostone pretreatment was found to be more effective at bowel cleansing in each segment of the colon when compared with split-dose PEG-E with placebo (P < 0.001). Patients enrolled in the lubiprostone treatment arm rated the overall experience as more tolerable (P 0.003) and complained of less abdominal bloating (P 0.049). No differences were observed between the groups for treatment-emergent side effects or adverse events (P > 0.05). Single-dose lubiprostone prior to split-dose PEG-E without dietary restriction significantly improves colonic mucosa visualization during colonoscopy and is well tolerated by patients.

  8. Novel Injectable Calcium Phosphate Bone Cement from Wet Chemical Precipitation Method

    NASA Astrophysics Data System (ADS)

    Hablee, S.; Sopyan, I.; Mel, M.; Salleh, H. M.; Rahman, M. M.; Singh, R.

    2017-06-01

    Calcium phosphate cement has been prepared via chemical precipitation method for injectable bone filling materials. Calcium hydroxide, Ca(OH)2, and diammonium hydrogen phosphate, (NH4)2HPO4, were used as calcium and phosphorus precursors respectively. The synthesized powder was mixed with water at different powder-to-liquid (P/L) ratios, which was adjusted at 0.8, 0.9, 1.0, 1.1 and 1.2. The influence of P/L ratio on the injectability, setting time and mechanical strength of calcium phosphate cement paste has been evaluated. The synthesized powder appeared as purely hydroxyapatite with nanosized and agglomerated spherical particles. All cement pastes show excellent injectability except for the paste with P/L ratio 1.2. Calcium phosphate cement with P/L ratio 1.1 shows the ideal cement for bone filler application with good injectability, the initial and final setting times of 30 min and 160 min, and the compression strength of 2.47 MPa. The result indicated that the newly developed calcium phosphate cement is physically suitable for bone filler application. This paper presents our investigation on the effect of P/L ratio on the handling and mechanical properties of calcium phosphate cement prepared via wet chemical precipitation method.

  9. International spinal cord injury bowel function basic data set (Version 2.0).

    PubMed

    Krogh, K; Emmanuel, A; Perrouin-Verbe, B; Korsten, M A; Mulcahey, M J; Biering-Sørensen, F

    2017-07-01

    International expert working group. To revise the International Spinal Cord Injury (SCI) Bowel Function Basic Data Set as a standardized format for the collecting and reporting of a minimal amount of information on bowel function in clinical practice and research. Working group appointed by the American Spinal injury association (ASIA) and the International Spinal Cord Society (ISCoS). The draft prepared by the working group was reviewed by the International SCI Data Set Committee and later by members of the ISCoS Executive and Scientific Committees and the ASIA board. The revised data set was posted on the ASIA and ISCoS websites for 1 month to allow further comments and suggestions. Changes resulting from a Delphi process among experts in children with SCI were included. Members of ISCoS Executive and Scientific Committees and the ASIA board made a final review and approved the data set. The International SCI Bowel Function Basic Data Set (Version 2.0) consists of the following 16 items: date of data collection, gastrointestinal and anal sphincter dysfunction unrelated to SCI, surgical procedures on the gastrointestinal tract, defecation method and bowel-care procedures, average time required for defecation, frequency of defecation, uneasiness, headache or perspiration during defecation, digital stimulation or evacuation of the anorectum, frequency of fecal incontinence, flatus incontinence, need to wear pad or plug, oral laxatives and prokinetics, anti-diarrheal agents, perianal problems, abdominal pain and discomfort and the neurogenic bowel dysfunction score. The International SCI Bowel Function Basic Data Set (Version 2.0) has been developed.

  10. A multifaceted knowledge translation strategy can increase compliance with guideline recommendations for mechanical bowel preparation.

    PubMed

    Eskicioglu, Cagla; Pearsall, Emily; Victor, J Charles; Aarts, Mary-Anne; Okrainec, Allan; McLeod, Robin S

    2015-01-01

    The successful transfer of evidence into clinical practice is a slow and haphazard process. We report the outcome of a 5-year knowledge translation (KT) strategy to increase adherence with a clinical practice guideline (CPG) for mechanical bowel preparation (MBP) for elective colorectal surgery patients. A locally tailored CPG recommending MBP practices was developed. Data on MBP practices were collected at six University of Toronto hospitals before CPG implementation as well as after two separate KT strategies. KT strategy #1 included development of the CPG, education by opinion leaders, reminder cards, and presentations of data. KT strategy #2 included selection of hospital champions, development of communities of practice, education, reminder cards, electronic updates, pre-printed standardized orders, and audit and feedback. A total of 744 patients (400 males, 344 females, mean age 57.0) were included. Compliance increased from 58.6 to 70.4% after KT strategy #1 and to 81.1% after KT strategy #2 (p < 0.001). Using a tailored KT strategy, increased compliance was observed with CPG recommendations over time suggesting that a longitudinal KT strategy is required to increase and sustain compliance with recommendations. Furthermore, different strategies may be required at different times (i.e., educational sessions initially and reminders and standardized orders to maintain adherence).

  11. Improving of bowel cleansing effect for polyethylene glycol with ascorbic acid using simethicone: A randomized controlled trial.

    PubMed

    Yoo, In Kyung; Jeen, Yoon Tae; Kang, Seung Hun; Lee, Jae Hyung; Kim, Seung Han; Lee, Jae Min; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Chun, Hoon Jai; Lee, Hong Sik; Kim, Chang Duck

    2016-07-01

    Low-volume polyethylene glycol with ascorbic acid (PEG-Asc) use is reported to be as safe and effective as traditional 4-L polyethylene glycol use. However, PEG-Asc produces bubbles, which cause problems during colonoscopy. Data on the effects of using antifoaming agents such as simethicone with PEG-Asc are lacking. The aim of this CONSORT-prospective, randomized, observer-blinded, controlled trial is to compare the quality of bowel preparation and compliance between PEG-Asc users and PEG-Asc plus simethicone users. Adult outpatients aged 18 to 80 years undergoing colonoscopy were recruited to the study. Two hundred sixty patients were randomly assigned to 1 of 2 treatment arms, PEG-Asc or PEG-Asc plus simethicone. The primary outcome measure was the bowel cleansing quality using Boston bowel preparation scale and bubble scores. The secondary outcome measures were patient tolerability and doctor tolerability. The simethicone group showed superior cleansing results (6-9 Boston scale scores: 99% vs. 84%, <5% bubble scores: 96% vs. 49%, P < 0.001) and fewer gastrointestinal symptoms (abdominal fullness: 24% vs. 55%, colicky pain: 5% vs. 24%, P < 0.001) than the non-simethicone group. Moreover, endoscopist fatigue during colonoscopy was lower in the simethicone group than in the non-simethicone group (1.31 ± 0.75 vs. 2.97 ± 2.14, P < 0.001). PEG-Asc plus simethicone use was more effective and associated with better patient and endoscopist tolerance than PEG-Asc use. Therefore, this combination is recommended as one of the promising methods for bowel preparation before colonoscopy.

  12. Evaluation of two minimal-preparation regimes for CT colonography: optimising image quality and patient acceptability

    PubMed Central

    Pollentine, A; Mortimer, A; Mccoubrie, P; Archer, L

    2012-01-01

    Objective To compare a 2 day bowel preparation regime of barium, iodine and a mild stimulant laxative with a 1 day iodine-only regime for CT colonography (CTC). Methods 100 consecutive patients underwent CTC. The first 50 patients (Regime 1) ingested 1 bisacodyl tablet twice a day 3 days before CTC and 1 dose each of 50 ml of barium and 20 ml of iodinated contrast per day starting 2 days before CTC. The second 50 patients (Regime 2) ingested 3 doses of iodinated contrast over 24 h prior to CTC. Volumes of residual stool and fluid, and the effectiveness of stool and fluid tagging, were graded according to methods established by Taylor et al (Taylor S, Slaker A, Burling D, Tam E, Greenhalgh R, Gartner L, et al. CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging. Eur Radiol 2008; 18: 32–42). A 3 day low-residue diet was taken by both cohorts. Questionnaires rating the side-effects and burden of the bowel preparation were compared to a control cohort of patients undergoing barium enema. Results The proportion of colons producing none/scattered stool (score 1) was 90.3% with Regime 1 and 65.0% with Regime 2 (p<0.005). Any residual stool was significantly better tagged with Regime 1 (score 5), with 91.7% of Regime 1 exhibiting optimum tagging vs 71.3% of Regime 2 (p<0.05). No significant differences in side-effects between the bowel preparation regimes for CTC were elicited. Bowel preparation for barium enema was tolerated significantly worse than both of the CTC bowel preparation regimes. Conclusion Regime 1, containing a 3 day preparation of a mild laxative, barium and iodine, produced a significantly better prepared colon, with no difference in patient acceptability. PMID:22422379

  13. Evaluation of two minimal-preparation regimes for CT colonography: optimising image quality and patient acceptability.

    PubMed

    Pollentine, A; Mortimer, A; McCoubrie, P; Archer, L

    2012-08-01

    To compare a 2 day bowel preparation regime of barium, iodine and a mild stimulant laxative with a 1 day iodine-only regime for CT colonography (CTC). 100 consecutive patients underwent CTC. The first 50 patients (Regime 1) ingested 1 bisacodyl tablet twice a day 3 days before CTC and 1 dose each of 50 ml of barium and 20 ml of iodinated contrast per day starting 2 days before CTC. The second 50 patients (Regime 2) ingested 3 doses of iodinated contrast over 24 h prior to CTC. Volumes of residual stool and fluid, and the effectiveness of stool and fluid tagging, were graded according to methods established by Taylor et al (Taylor S, Slaker A, Burling D, Tam E, Greenhalgh R, Gartner L, et al. CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging. Eur Radiol 2008; 18: 32-42). A 3 day low-residue diet was taken by both cohorts. Questionnaires rating the side-effects and burden of the bowel preparation were compared to a control cohort of patients undergoing barium enema. The proportion of colons producing none/scattered stool (score 1) was 90.3% with Regime 1 and 65.0% with Regime 2 (p<0.005). Any residual stool was significantly better tagged with Regime 1 (score 5), with 91.7% of Regime 1 exhibiting optimum tagging vs 71.3% of Regime 2 (p<0.05). No significant differences in side-effects between the bowel preparation regimes for CTC were elicited. Bowel preparation for barium enema was tolerated significantly worse than both of the CTC bowel preparation regimes. Regime 1, containing a 3 day preparation of a mild laxative, barium and iodine, produced a significantly better prepared colon, with no difference in patient acceptability.

  14. Small Bowel Transplant

    PubMed Central

    2003-01-01

    EXECUTIVE SUMMARY Objective The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of small bowel transplant in the treatment of intestinal failure. Small Bowel Transplantation Intestinal failure is the loss of absorptive capacity of the small intestine that results in an inability to meet the nutrient and fluid requirements of the body via the enteral route. Patients with intestinal failure usually receive nutrients intravenously, a procedure known as parenteral nutrition. However, long-term parenteral nutrition is associated with complications including liver failure and loss of venous access due to recurrent infections. Small bowel transplant is the transplantation of a cadaveric intestinal allograft for the purpose of restoring intestinal function in patients with irreversible intestinal failure. The transplant may involve the small intestine alone (isolated small bowel ISB), the small intestine and the liver (SB-L) when there is irreversible liver failure, or multiple organs including the small bowel (multivisceral MV or cluster). Although living related donor transplant is being investigated at a limited number of centres, cadaveric donors have been used in most small bowel transplants. The actual transplant procedure takes approximately 12-18 hours. After intestinal transplant, the patient is generally placed on prophylactic antibiotic medication and immunosuppressive regimen that, in the majority of cases, would include tacrolimus, corticosteroids and an induction agent. Close monitoring for infection and rejection are essential for early treatment. Medical Advisory Secretariat Review The Medical Advisory Secretariat undertook a review of 35 reports from 9 case series and 1 international registry. Sample size of the individual studies ranged from 9 to 155. As of May 2001, 651 patients had received small bowel transplant procedures worldwide. According to information from the Canadian Organ Replacement

  15. Properties of Powder Composite Polyhydroxybutyrate-Chitosan-Calcium Phosphate System

    NASA Astrophysics Data System (ADS)

    Medvecky, L.; Stulajterova, R.; Giretova, M.; Faberova, M.

    2017-12-01

    Prepared powder polyhydroxybutyrate - chitosan - calcium phosphate composite system with 10 wt % of biopolymer component can be utilized as biocement which is characterized by the prolonged setting time and achieves wash out resistance after 5 minutes of setting. The origin powder tetracalcium phosphate/nanomonetite agglomerates were coated with the thin layer of biopolymer which decelerates both the transformation rate of calcium phosphates and hardening process of composites. The porosity of hardened composite was around 62% and the compressive strength (8 MPa) was close to trabecular bone. No cytotoxicity of composite resulted from live/dead staining of osteoblasts cultured on substrates.

  16. MiraLAX-Gatorade Bowel Prep vs. GoLytely Prior to Screening Colonoscopy: An Endoscopic Database Study in a Community Hospital

    PubMed Central

    Shieh, Frederick K.; Gunaratnam, Naresh; Mohamud, Sagal O.; Schoenfeld, Philip

    2012-01-01

    Background Polyethylene Glycol-3350 without electrolytes (MiraLAX®; Schering-Plough Healthcare Products Inc.) + a carbohydrate-electrolyte solution (Gatorade; PepsiCo Inc.) + bisacodyl is frequently used for bowel cleansing, although limited data quantifies its efficacy and safety. No prior studies have assessed this in a community setting or with PM-only dosing, which is still used frequently. Aim To compare the frequency of excellent/good/fair/poor bowel cleansing with PM-only dosing of MiraLAX®-Gatorade-bisacodyl vs. 4L GoLytely®. Methods This is a retrospective endoscopic database analysis of ≥ 50 year old average-risk individuals with a normal screening colonoscopy at a community hospital and ambulatory endoscopy center. Data was extracted for the last four months when 4L GoLytely® was the preferred bowel purgative and the first 4 months when 238g MiraLAX® in 64 ounces Gatorade and four 5-mg bisacodyl tablets became the preferred purgative. All patients used PM-only dosing of bowel purgative. Results 778 subjects [GoLytely® (n=395) vs. MiraLAX® + Gatorade + bisacodyl (n=383)] were identified. Patients who took the MiraLAX® bowel preparation were more likely to achieve an excellent/good bowel cleansing compared to patients taking the GoLytely® preparation (93.3% vs. 89.3%, respectively; p = 0.048). However, when only ASA Class I patients are studied, there was no difference in frequency of excellent/good bowel cleansing (91.1% vs 93.6%, respectively; p = 0.498). No serious adverse events were identified. An excellent/good bowel cleansing was strongly associated with a recommendation for repeat colonoscopy in 10 years compared to patients with a fair cleansing [OR = 28.01; 95% CI: 13.96-56.19]. Conclusions The MiraLAX® + Gatorade + bisacodyl combination produces similar rates of excellent/good bowel cleansing as compared to GoLytely® in most average-risk individuals undergoing colonoscopy for CRC screening in a community setting. PMID:23060223

  17. Stricturoplasty-a bowel-sparing option for long segment small bowel Crohn's disease.

    PubMed

    Limmer, Alexandra M; Koh, Hoey C; Gilmore, Andrew

    2017-08-01

    Stricturoplasty is a surgical option for management of severe stricturing Crohn's disease of the small bowel. It avoids the need for small bowel resection and the associated metabolic complications. This report contrasts the indications and technical aspects of two different stricturoplasty techniques. Case 1 describes an extensive Michelassi (side-to-side isoperistaltic) stricturoplasty performed for a 100 cm segment of diseased small bowel in a 45-year-old patient. Case 2 describes the performance of 12 Heineke-Mikulicz stricturoplasties in a 23-year-old patient with multiple short fibrotic strictures.

  18. Stricturoplasty—a bowel-sparing option for long segment small bowel Crohn's disease

    PubMed Central

    Koh, Hoey C.; Gilmore, Andrew

    2017-01-01

    Abstract Stricturoplasty is a surgical option for management of severe stricturing Crohn's disease of the small bowel. It avoids the need for small bowel resection and the associated metabolic complications. This report contrasts the indications and technical aspects of two different stricturoplasty techniques. Case 1 describes an extensive Michelassi (side-to-side isoperistaltic) stricturoplasty performed for a 100 cm segment of diseased small bowel in a 45-year-old patient. Case 2 describes the performance of 12 Heineke-Mikulicz stricturoplasties in a 23-year-old patient with multiple short fibrotic strictures. PMID:29423160

  19. The aluminum phosphate zone in the Peace River area, land-pebble phosphate field, Florida

    USGS Publications Warehouse

    Cathcart, James B.

    1953-01-01

    The Peace River area, comprising T. 30 and 31 S., R. 24 and 25 E., contains a thicker and more persistent aluminum phosphate zone, and one that is higher in P2O5 and uranium content than is known elsewhere in the land-pebble phosphate district. This report has been prepared to bring together all of the information on the aluminum phosphate zone in the area where the first plant to treat this material will probably be located. The area may be divided into three physiographic units, (1) the ridge, (2) the flatwoods, and (3) the valley. Maps showing distribution and grade of the aluminum phosphate zone indicate that the zone is thin or absent in the ridge unit, thickest and most persistent, and of the best grade in P2O5 and uranium in the flatwoods unit, and absent or very low in grade in the valley unit. Maps of thickness and of chemical composition show that even in favorable areas there are places where the aluminum phosphate zone is missing or of questionable economic importance. The distribution maps also show that areas of high P2O5 and high uranium content coincide closely. Areas containing thick aluminum phosphate material usually have high uranium and P2O5 contents. It is estimated that an average of 13,000 tons per day of aluminum phosphate material might be mined from this area. This figure is based on the probable amount of time, per year, that mining would be in favorable ground. When all mines in the area are in favorable ground, the tonnage per day might be about 23,000 tons. Tonnages of aluminum phosphate material have been computed for about 36 percent of the area of T. 30 S., R. 25 E., and for 18 percent of the area of T. 31 S., R. 25 E. The total inferred tonnage is about 150,000,000 short tons, with an average grade of 0.012 percent U3O8.

  20. The Role of Diet in Inflammatory Bowel Disease.

    PubMed

    Shivashankar, Raina; Lewis, James D

    2017-05-01

    Diet may play both a causal and therapeutic role for inflammatory bowel disease (IBD). Physicians caring for patients with IBD are often asked to make dietary recommendations. However, there are no well-established guidelines on the use of diet as a treatment of IBD. In this review, we describe the evidence supporting diet as a potential cause for IBD, patient-perceived symptoms based on diet, current research on various diets as a treatment for IBD, and areas of future research. New studies in murine models suggest that dietary emulsifiers may trigger the gut inflammatory cascade. New studies of restriction diets in patients have shown a relationship between dietary intake, symptoms, and bowel inflammation. Until several ongoing clinical trials are completed, a reasonable approach to dietary recommendations for patients with IBD is to propose a well-balanced, healthy (low-fat, low-sugar) diet prepared from fresh ingredients, such as the Mediterranean diet, with exclusions of self-identified foods that worsen or trigger IBD-related symptoms.

  1. Tight junctions in inflammatory bowel diseases and inflammatory bowel disease associated colorectal cancer

    PubMed Central

    Landy, Jonathan; Ronde, Emma; English, Nick; Clark, Sue K; Hart, Ailsa L; Knight, Stella C; Ciclitira, Paul J; Al-Hassi, Hafid Omar

    2016-01-01

    Inflammatory bowel diseases are characterised by inflammation that compromises the integrity of the epithelial barrier. The intestinal epithelium is not only a static barrier but has evolved complex mechanisms to control and regulate bacterial interactions with the mucosal surface. Apical tight junction proteins are critical in the maintenance of epithelial barrier function and control of paracellular permeability. The characterisation of alterations in tight junction proteins as key players in epithelial barrier function in inflammatory bowel diseases is rapidly enhancing our understanding of critical mechanisms in disease pathogenesis as well as novel therapeutic opportunities. Here we give an overview of recent literature focusing on the role of tight junction proteins, in particular claudins, in inflammatory bowel diseases and inflammatory bowel disease associated colorectal cancer. PMID:27003989

  2. Bowel injury following induced abortion.

    PubMed

    Jhobta, R S; Attri, A K; Jhobta, A

    2007-01-01

    Bowel injury is an uncommonly reported yet serious complication of induced abortion, which is often performed illegally by persons without any medical training in developing countries. A sudden increase in cases prompted the authors to analyze this problem. A retrospective review was done of 11 cases of bowel injury following induced abortion seen over 2 years at Government Medical College and Hospital, Chandigarh, India. Young, married women of low socioeconomic status with a strong preference for male children were the predominant recipients of induced abortion in India. The terminal ileum and pelvic colon were the most commonly injured portions of the bowel owing to their anatomic locations. Preoperative resuscitation, then resection with exteriorization of bowel and thorough peritoneal lavage, is the treatment for bowel injury incurred during induced abortion when the patient presents late.

  3. A Novel Polymer-Synthesized Ceramic Composite Based System for Bone Repair: Osteoblast Growth on Scaffolds with Varied Calcium Phosphate Content

    DTIC Science & Technology

    2005-01-01

    demongtrated the synthesis of degradable scaffolds from PLAGA /calcium phosphate composite microspheres in which an amorphous calcium phosphate is...EXPERIMENTAL DETAILS Scaffold Preparation Scaffolds were prepared as described in detail previously [3]. Briefly, PLAGA /calcium phosphate composite...culture polystyrene (TCPS) 2- pure PLAGA microspheres 64 3- composite microsphere matrices with a low polymer/ceramic ratio 4- composite microsphere

  4. Osteoporosis in Inflammatory Bowel Disease

    PubMed Central

    Ali, Tauseef; Lam, David; Bronze, Michael S.; Humphrey, Mary Beth

    2010-01-01

    Osteoporosis commonly afflicts patients with inflammatory bowel disease, and many factors link the 2 states together. A literature review was conducted about the pathophysiology of osteoporosis in relation to inflammatory bowel disease. Screening guidelines for osteoporosis in general as well as those directed at patients with inflammatory bowel disease are reviewed, as are currently available treatment options. The purpose of this article is to increase physician awareness about osteopenia and osteoporosis occurring in patients with inflammatory bowel disease and to provide basic, clinically relevant information about the pathophysiology and guidelines to help them treat these patients in a cost-effective manner. PMID:19559158

  5. Accuracy of abdominal auscultation for bowel obstruction.

    PubMed

    Breum, Birger Michael; Rud, Bo; Kirkegaard, Thomas; Nordentoft, Tyge

    2015-09-14

    To investigate the accuracy and inter-observer variation of bowel sound assessment in patients with clinically suspected bowel obstruction. Bowel sounds were recorded in patients with suspected bowel obstruction using a Littmann(®) Electronic Stethoscope. The recordings were processed to yield 25-s sound sequences in random order on PCs. Observers, recruited from doctors within the department, classified the sound sequences as either normal or pathological. The reference tests for bowel obstruction were intraoperative and endoscopic findings and clinical follow up. Sensitivity and specificity were calculated for each observer and compared between junior and senior doctors. Interobserver variation was measured using the Kappa statistic. Bowel sound sequences from 98 patients were assessed by 53 (33 junior and 20 senior) doctors. Laparotomy was performed in 47 patients, 35 of whom had bowel obstruction. Two patients underwent colorectal stenting due to large bowel obstruction. The median sensitivity and specificity was 0.42 (range: 0.19-0.64) and 0.78 (range: 0.35-0.98), respectively. There was no significant difference in accuracy between junior and senior doctors. The median frequency with which doctors classified bowel sounds as abnormal did not differ significantly between patients with and without bowel obstruction (26% vs 23%, P = 0.08). The 53 doctors made up 1378 unique pairs and the median Kappa value was 0.29 (range: -0.15-0.66). Accuracy and inter-observer agreement was generally low. Clinical decisions in patients with possible bowel obstruction should not be based on auscultatory assessment of bowel sounds.

  6. Accuracy of abdominal auscultation for bowel obstruction

    PubMed Central

    Breum, Birger Michael; Rud, Bo; Kirkegaard, Thomas; Nordentoft, Tyge

    2015-01-01

    AIM: To investigate the accuracy and inter-observer variation of bowel sound assessment in patients with clinically suspected bowel obstruction. METHODS: Bowel sounds were recorded in patients with suspected bowel obstruction using a Littmann® Electronic Stethoscope. The recordings were processed to yield 25-s sound sequences in random order on PCs. Observers, recruited from doctors within the department, classified the sound sequences as either normal or pathological. The reference tests for bowel obstruction were intraoperative and endoscopic findings and clinical follow up. Sensitivity and specificity were calculated for each observer and compared between junior and senior doctors. Interobserver variation was measured using the Kappa statistic. RESULTS: Bowel sound sequences from 98 patients were assessed by 53 (33 junior and 20 senior) doctors. Laparotomy was performed in 47 patients, 35 of whom had bowel obstruction. Two patients underwent colorectal stenting due to large bowel obstruction. The median sensitivity and specificity was 0.42 (range: 0.19-0.64) and 0.78 (range: 0.35-0.98), respectively. There was no significant difference in accuracy between junior and senior doctors. The median frequency with which doctors classified bowel sounds as abnormal did not differ significantly between patients with and without bowel obstruction (26% vs 23%, P = 0.08). The 53 doctors made up 1378 unique pairs and the median Kappa value was 0.29 (range: -0.15-0.66). CONCLUSION: Accuracy and inter-observer agreement was generally low. Clinical decisions in patients with possible bowel obstruction should not be based on auscultatory assessment of bowel sounds. PMID:26379407

  7. The impact of bowel preparation on the severity of anastomotic leak in colon cancer patients.

    PubMed

    Haskins, Ivy N; Fleshman, James W; Amdur, Richard L; Agarwal, Samir

    2016-12-01

    The routine use of preoperative bowel preparation (BP) is heavily debated in the colorectal surgery literature. To date, no study has investigated the effect preoperative BP has on patients with an established anastomotic leak. We therefore seek to compare the severity of patient morbidity and mortality in patients with a known anastomotic leak based on type of preoperative BP using the Targeted Colectomy American College of Surgeons National Surgery Quality Improvement Program (ACS-NSQIP). All elective colon cancer operations performed with primary anastomosis were identified within the targeted colectomy database from 2012 to 2013. Patients who experienced a postoperative anastomotic leak were identified and stratified based on preoperative BP. Variables that had an association with mechanical BP at P < 0.10 were included in a multivariate logistic regression model to determine if BP was independently associated with postoperative morbidity and mortality. A total of 6,297 patients underwent elective colon resection with primary anastomosis for colon cancer. Two hundred and nineteen (3.5%) patients experienced an anastomotic leak. Thirty-day wound morbidity and mortality was not worse in patients who underwent preoperative BP. BP is not associated with worse patients outcomes in those patients with an established anastomotic leak following elective colon research with primary anastomosis. J. Surg. Oncol. 2016;114:810-813. © 2016 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. High-dose senna compared with conventional PEG-ES lavage as bowel preparation for elective colonoscopy: a prospective, randomized, investigator-blinded trial.

    PubMed

    Radaelli, Franco; Meucci, Gianmichele; Imperiali, Gianni; Spinzi, Giancarlo; Strocchi, Enrico; Terruzzi, Vittorio; Minoli, Giorgio

    2005-12-01

    To compare the efficacy and patient acceptance of an oral high dose of senna to conventional polyethylene glycol-electrolyte lavage solution (PEG-ES) in adults undergoing elective colonoscopy. Consecutive outpatients referred for elective colonoscopy were prospectively randomly assigned to receive, the day before the procedure, either 24 tablets of 12 mg senna, divided into two doses at 1 p.m. and 9 p.m. (senna group, n=191), or standard 4-L PEG-ES (PEG-ES group, n=92). The overall quality of colon cleansing (primary outcome measure) and cleansing in the right colon were evaluated using the Aronchick scoring scale (1=excellent to 4=inadequate) by the investigator/endoscopist who was blinded to the treatment assignment. Patient acceptance and the safety of the preparation were assessed by a nurse, using a structured questionnaire covering compliance with the dosing, overall tolerance of the preparation (1=none or mild discomfort to 4=severely distressing), and adverse events. The quality of colon cleansing, overall tolerance of the preparation, and compliance were significantly better with senna; overall cleansing was excellent or good in 90.6% of patients in the senna group and in 79.7% in the PEG-ES group (p= 0.003). The percentage of procedures rescheduled because of insufficient colon cleansing was 7.3% in the PEG-ES group and 2.6% in the senna group (p=0.035). Multivariate logistic regression modeling showed the PEG-ES preparation as negative independent predictor of unsuccessful bowel cleansing. The incidence of adverse reactions was similar in the two groups; patients who received senna experienced significantly less nausea and vomiting, but more abdominal pain. An oral high dose of senna is a valid alternative to standard PEG-ES for outpatient colonoscopy preparation.

  9. The impact of education and cooking methods on serum phosphate levels in patients on hemodialysis: 1-year study.

    PubMed

    Vrdoljak, Ivica; Panjkota Krbavčić, Ines; Bituh, Martina; Leko, Ninoslav; Pavlović, Draško; Vrdoljak Margeta, Tea

    2017-04-01

    Control of serum phosphate is important for patients on hemodialysis. The aim of the study was to determine if education based on phosphorus-reducing techniques in food preparation and thermal processing, and accordingly prepared and applied diets, will lead to better outcomes than a standard education program to improve phosphate control in patients on hemodialysis. Forty-seven patients on hemodialysis were divided between an intervention and a control group. All subjects received training about nutrition for hemodialysis patients by trained dietitian. In addition, subjects in the intervention group received additional training in phosphorus-reducing techniques in food preparation and received two hospital meals prepared using suggested cooking methods to reduce the phosphate content of food during dialysis treatment. Serum phosphate, serum albumin, and anthropometric parameters were measured, while nPCR was calculated, at the baseline and during the 1-year study. No differences in serum phosphate levels were observed between intervention (1.68 mmol/L [1.48-2.03]) and control group (1.88 mmol/L [1.57-2.2]) at baseline (P = 0.130). Although not statistically significant between groups the mean reduction was more apparent in the intervention group (-0.3 mmol/L (-0.4 to 0.1) vs. -0.2 (-0.5 to 0.1)), and lead to significantly reduction of phosphate binder therapy. During the study, the nPCR and anthropometric status of the patients did not change significantly. Providing additional education to hemodialysis patients on the specific cooking methods and accordingly prepared meals may decrease serum phosphate levels without significantly affecting nutritional status which may be useful in helping to prevent and treat hyperphosphatemia. © 2016 International Society for Hemodialysis.

  10. Inflammatory Bowel Disease in Primary Immunodeficiencies.

    PubMed

    Kelsen, Judith R; Sullivan, Kathleen E

    2017-08-01

    Inflammatory bowel disease is most often a polygenic disorder with contributions from the intestinal microbiome, defects in barrier function, and dysregulated host responses to microbial stimulation. There is, however, increasing recognition of single gene defects that underlie a subset of patients with inflammatory bowel disease, particularly those with early-onset disease, and this review focuses on the primary immunodeficiencies associated with early-onset inflammatory bowel disease. The advent of next-generation sequencing has led to an improved recognition of single gene defects underlying some cases of inflammatory bowel disease. Among single gene defects, immune response genes are the most frequent category identified. This is also true of common genetic variants associated with inflammatory bowel disease, supporting a pivotal role for host responses in the pathogenesis. This review focuses on practical aspects related to diagnosis and management of children with inflammatory bowel disease who have underlying primary immunodeficiencies.

  11. 76 FR 9560 - Notice of Intent To Prepare a Draft Areawide Environmental Impact Statement for Phosphate Mining...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... Draft Areawide Environmental Impact Statement for Phosphate Mining Affecting Waters of the United States... Section 404 of the Clean Water Act (CWA) from phosphate mining companies in Central and Southwest Florida... determined that, when viewed collectively, the separate proposed phosphate mining-related projects have...

  12. Using segmented regression analysis of interrupted time series data to assess colonoscopy quality outcomes of a web-enhanced implementation toolkit to support evidence-based practices for bowel preparation: a study protocol.

    PubMed

    Ramsey, Alex T; Maki, Julia; Prusaczyk, Beth; Yan, Yan; Wang, Jean; Lobb, Rebecca

    2015-06-07

    While there is convincing evidence on interventions to improve bowel preparation for patients, the evidence on how to implement these evidence-based practices (EBPs) in outpatient colonoscopy settings is less certain. The Strategies to Improve Colonoscopy (STIC) study compares the effect of two implementation strategies, physician education alone versus physician education plus an implementation toolkit for staff, on adoption of three EBPs (split-dosing of bowel preparation, low-literacy education, teach-back) to improve pre-procedure and intra-procedure quality measures. The implementation toolkit contains a staff education module, website containing tools to support staff in delivering EBPs, tailored patient education materials, and brief consultation with staff to determine how the EBPs can be integrated into the existing workflow. Given adaptations to the implementation plan and intentional flexibility in the delivery of the EBPs, we utilize a pragmatic study to balance external validity with demonstrating effectiveness of the implementation strategies. Participants will include all outpatient colonoscopy physicians, staff, and patients from a convenience sample of six endoscopy settings. Aim #1 will explore the relative effect of two strategies to implement patient-level EBPs on adoption and clinical quality outcomes. We will assess the change in level and trends of clinical quality outcomes (i.e., adequacy of bowel preparation, adenoma detection) using segmented regression analysis of interrupted time series data with two groups (intervention and delayed start). Aim #2 will examine the influence of organizational readiness to change on EBP implementation. We use a PRECIS diagram to reflect the extent to which each indicator of the study was pragmatic versus explanatory, revealing a largely pragmatic study. Implementation challenges have already motivated several adaptations to the original plan, reflecting the nature of implementation in real-world healthcare

  13. Three-step preparation and purification of phosphorus-33-labeled creatine phosphate of high specific activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savabi, F.; Geiger, P.J.; Bessman, S.P.

    1984-03-01

    Rabbit heart mitochondria were used as a source of enzymes for the synthesis of phosphorus-labeled creatine phosphate. This method is based on the coupled reaction between mitochondrial oxidative phosphorylation and mitochondrial-bound creatine kinase. It is possible to convert more than 90% of the inorganic phosphate (P/sub i/) to creatine phosphate. The method used only small amounts of adenine nucleotides which led to a product with only slight nucleotide contamination. This could be removed by activated charcoal extraction. For further purification, a method for the removal of residual P/sub i/ is described. 20 references.

  14. Sphingosine-1-phosphate receptor-1 (S1P1) is expressed by lymphocytes, dendritic cells, and endothelium and modulated during inflammatory bowel disease.

    PubMed

    Karuppuchamy, T; Behrens, E-H; González-Cabrera, P; Sarkisyan, G; Gima, L; Boyer, J D; Bamias, G; Jedlicka, P; Veny, M; Clark, D; Peach, R; Scott, F; Rosen, H; Rivera-Nieves, J

    2017-01-01

    The sphingosine-1-phosphate receptor-1 (S1P 1 ) agonist ozanimod ameliorates ulcerative colitis, yet its mechanism of action is unknown. Here, we examine the cell subsets that express S1P 1 in intestine using S1P 1 -eGFP mice, the regulation of S1P 1 expression in lymphocytes after administration of dextran sulfate sodium (DSS), after colitis induced by transfer of CD4 + CD45RB hi cells, and by crossing a mouse with TNF-driven ileitis with S1P 1 -eGFP mice. We then assayed the expression of enzymes that regulate intestinal S1P levels, and the effect of FTY720 on lymphocyte behavior and S1P 1 expression. We found that not only T and B cells express S1P 1 , but also dendritic (DC) and endothelial cells. Furthermore, chronic but not acute inflammatory signals increased S1P 1 expression, while the enzymes that control tissue S1P levels in mice and humans with inflammatory bowel disease (IBD) were uniformly dysregulated, favoring synthesis over degradation. Finally, we observed that FTY720 reduced T-cell velocity and induced S1P 1 degradation and retention of Naïve but not effector T cells. Our data demonstrate that chronic inflammation modulates S1P 1 expression and tissue S1P levels and suggests that the anti-inflammatory properties of S1PR agonists might not be solely due to their lymphopenic effects, but also due to potential effects on DC migration and vascular barrier function.

  15. Hydrothermal synthesis of porous triphasic hydroxyapatite/(alpha and beta) tricalcium phosphate.

    PubMed

    Vani, R; Girija, E K; Elayaraja, K; Prakash Parthiban, S; Kesavamoorthy, R; Narayana Kalkura, S

    2009-12-01

    A novel, porous triphasic calcium phosphate composed of nonresorbable hydroxyapatite (HAp) and resorbable tricalcium phosphate (alpha- and beta-TCP) has been synthesized hydrothermally at a relatively low temperature. The calcium phosphate precursor for hydrothermal treatment was prepared by gel method in the presence of ascorbic acid. XRD, FT-IR, Raman analyses confirmed the presence of HAp/TCP. The surface area and average pore size of the samples were found to be 28 m2/g and 20 nm, respectively. The samples were found to be bioactive in simulated body fluid (SBF).

  16. Injectable TEMPO-oxidized nanofibrillated cellulose/biphasic calcium phosphate hydrogel for bone regeneration.

    PubMed

    Safwat, Engie; Hassan, Mohammad L; Saniour, Sayed; Zaki, Dalia Yehia; Eldeftar, Mervat; Saba, Dalia; Zazou, Mohamed

    2018-05-01

    Nanofibrillated cellulose, obtained from rice straw agricultural wastes was used as a substrate for the preparation of a new injectable and mineralized hydrogel for bone regeneration. Tetramethyl pyridine oxyl (TEMPO) oxidized nanofibrillated cellulose, was mineralized through the incorporation of a prepared and characterized biphasic calcium phosphate at a fixed ratio of 50 wt%. The TEMPO-oxidized rice straw nanofibrillated cellulose was characterized using transmission electron microscopy, Fourier transform infrared, and carboxylic content determination. The injectability and viscosity of the prepared hydrogel were evaluated using universal testing machine and rheometer testing, respectively. Cytotoxicity and alkaline phosphatase level tests on osteoblast like-cells for in vitro assessment of the biocompatibility were investigated. Results revealed that the isolated rice straw nanofibrillated cellulose is a nanocomposite of the cellulose nanofibers and silica nanoparticles. Rheological properties of the tested materials are suitable for use as injectable material and of nontoxic effect on osteoblast-like cells, as revealed by the positive alkaline phosphate assay. However, nanofibrillated cellulose/ biphasic calcium phosphate hydrogel showed higher cytotoxicity and lower bioactivity test results when compared to that of nanofibrillated cellulose.

  17. Results of a Community-based, Randomized Study Comparing a Clear Liquid Diet With a Low-residue Diet Using a Magnesium Citrate Preparation for Screening and Surveillance Colonoscopies.

    PubMed

    Thukral, Chandrashekhar; Tewani, Sumeet K; Lake, Adam J; Shiels, Aaron J; Geissler, Kathy; Popejoy, Sara; Stafford, Megan; Vicari, Joseph J

    2017-11-03

    Current bowel preparations for colonoscopy include a clear liquid diet (CLD) along with consumption of a laxative. This dietary restriction along with large volume bowel preparations are barriers to compliance and willingness among patients in scheduling screening examinations. The aim of our study was to compare the efficacy and tolerability of a low-volume split dose magnesium citrate bowel preparation in patients on a low-residue diet (LRD) with those on a CLD. In this single center, single blinded, randomized controlled trial, patients scheduled for outpatient colonoscopies were assigned to either a CLD or a LRD 1 day before the examination. Both groups received a split dose magnesium citrate preparation. The quality of the preparation was rated using the Boston Bowel Preparation Scale (BBPS). Patient satisfaction and side effects were evaluated using a questionnaire. We were unable to detect a significant difference in the BBPS scores between the LRD and CLD groups (P=0.581). A significantly higher percentage of patients in the LRD group rated the diet as easy compared with the CLD group (P<0.001). Satisfaction scores were significantly higher in the LRD group, compared with the CLD group (P<0.001). The side effect profiles of both arms were similar. There was no significant difference between LRD and CLD in patients using a magnesium citrate bowel preparation for screening and surveillance colonoscopies. Patient satisfaction scores were higher with a LRD compared with a CLD. We believe the LRD should be the recommended diet in patients using a standard bowel preparation for screening and surveillance colonoscopy.

  18. [Comparison of colon-cleansing methods in preparation for colonoscopy-comparative of solutions of mannitol and sodium picosulfate].

    PubMed

    de Moura, Diogo Turiani; Guedes, Hugo; Tortoretto, Verônica; Arataque, Tayrê Pádua; de Moura, Eduardo Guimarães; Román, Juan Pablo; Rodela, Gustavo Luis; Artifon, Everson L

    2016-01-01

    The purpose of the present study is to compare intestinal preparation with mannitol and sodium picosulphate, assessing patient's acceptance, side effects and cleaning capacity. This is a prospective, nom randomized, blind study, in which the evaluator had no information about the preparation applied. The sample obtained was divided into two groups according to the bowel preparation applied, with 153 patients prepared with 10% mannitol and 84 patients with sodium picosulfate. The evaluation of colon preparation was done using the Boston Scale (Boston Bowel Preparation Scale - BBP) through a three-point scoring system for each of the three regions of the colon: right, left and transverse colon. Of the 237 patients that were evaluated, 146 (61.60%) were female and 91 (38.4%) were male. Regarding the group that used mannitol, 98 were female (64.05%) and 55 were male (35.95%). Among the patients who used sodium picosulfate, 48 were female (57.14%) and 36 were male (42.86%), with no statistical differences between both groups (p> 0.32). Considering that an adequate preparation scores ≥ 6 in the Boston Scale, the bowel cleansing preparation was satisfactory in both groups. 93% of the patients who used mannitol and 81% of the patients who used sodium picosulfate had adequate preparation (score of ≥ 6). Moreover, we consider that the average score in the preparation with Mannitol was 9, while the sodium picosulfate score was 7. There were no significant differences between the two groups. There is consensus among authors who state that colonoscopy's safety and success are highly related to the cleansing outcome, regardless of the method used. The same can be observed in the present study, on which both preparations were proved safe and effective for bowel cleansing, according to the Boston scale, as well as accepted by patients and free of complications.

  19. ION EXCHANGE SUBSTANCES BY SAPONIFICATION OF ALLYL PHOSPHATE POLYMERS

    DOEpatents

    Kennedy, J.

    1959-04-14

    An ion exchange resin having a relatively high adsorption capacity tor uranyl ion as compared with many common cations is reported. The resin comprises an alphyl-allyl hydrogen phosphate polymer, the alphyl group being either allyl or a lower alkyl group having up to 5 carbon atoins. The resin is prepared by polymerizing compounds such as alkyl-diallyl phosphate and triallyl phosphate in the presence of a free radical generating substance and then partially hydrolyzing the resulting polymer to cause partial replacement of organic radicals by cations. A preferred free radical gencrating agent is dibenzoyl peroxide. The partial hydrolysis is brought about by refluxing the polymer with concentrated aqueous NaOH for three or four hours.

  20. Safety of oral sulfates in rats and dogs contrasted with phosphate-induced nephropathy in rats.

    PubMed

    Pelham, Russell W; Russell, Robert G; Padgett, Eric L; Reno, Frederick E; Cleveland, Mark vB

    2009-01-01

    An oral sulfate salt solution (OSS), under development as a bowel cleansing agent for colonoscopy in humans, is studied in rats and dogs. In rats, amaximumpractical oral OSS dose (5 g/kg/d) is compared with an oral sodium phosphate (OSP) solution, both at about 7 times the clinical dose. OSS induces the intended effects of loose stools and diarrhea. In rats, higher urine sodium and potassium accompany higher clearance rates, considered adaptive to the osmotic load of OSS. OSS for 28 days is well tolerated in rats and dogs. In contrast, OSP causes increased mortality, reduced body weight and food consumption, severe kidney tubular degeneration, and calcium phosphate deposition in rats. These are accompanied by mineralization in the stomach and aorta, along with cardiac and hepatic degeneration and necrosis. The greater safety margin of OSS over OSP at similarmultiples of the clinical dose indicates its suitability for human use.

  1. MRI of the small bowel: can sufficient bowel distension be achieved with small volumes of oral contrast?

    PubMed

    Kinner, Sonja; Kuehle, Christiane A; Herbig, Sebastian; Haag, Sebastian; Ladd, Susanne C; Barkhausen, Joerg; Lauenstein, Thomas C

    2008-11-01

    Sufficient luminal distension is mandatory for small bowel imaging. However, patients often are unable to ingest volumes of currently applied oral contrast compounds. The aim of this study was to evaluate if administration of low doses of an oral contrast agent with high-osmolarity leads to sufficient and diagnostic bowel distension. Six healthy volunteers ingested at different occasions 150, 300 and 450 ml of a commercially available oral contrast agent (Banana Smoothie Readi-Cat, E-Z-EM; 194 mOsmol/l). Two-dimensional TrueFISP data sets were acquired in 5-min intervals up to 45 min after contrast ingestion. Small bowel distension was quantified using a visual five-grade ranking (5 = very good distension, 1 = collapsed bowel). Results were statistically compared using a Wilcoxon-Rank test. Ingestion of 450 ml and 300 ml resulted in a significantly better distension than 150 ml. The all-over average distension value for 450 ml amounted to 3.4 (300 ml: 3.0, 150 ml: 2.3) and diagnostic bowel distension could be found throughout the small intestine. Even 45 min after ingestion of 450 ml the jejunum and ileum could be reliably analyzed. Small bowel imaging with low doses of contrast leads to diagnostic distension values in healthy subjects when a high-osmolarity substance is applied. These findings may help to further refine small bowel MRI techniques, but need to be confirmed in patients with small bowel disorders.

  2. Preparation, Physical-Chemical Characterization, and Cytocompatibility of Polymeric Calcium Phosphate Cements

    PubMed Central

    Khashaba, Rania M.; Moussa, Mervet; Koch, Christopher; Jurgensen, Arthur R.; Missimer, David M.; Rutherford, Ronny L.; Chutkan, Norman B.; Borke, James L.

    2011-01-01

    Aim. Physicochemical mechanical and in vitro biological properties of novel formulations of polymeric calcium phosphate cements (CPCs) were investigated. Methods. Monocalcium phosphate, calcium oxide, and synthetic hydroxyapatite were combined with either modified polyacrylic acid, light activated polyalkenoic acid, or polymethyl vinyl ether maleic acid to obtain Types I, II, and III CPCs. Setting time, compressive and diametral strength of CPCs was compared with zinc polycarboxylate cement (control). Specimens were characterized using X-ray diffraction, scanning electron microscopy, and infrared spectroscopy. In vitro cytotoxicity of CPCs and control was assessed. Results. X-ray diffraction analysis showed hydroxyapatite, monetite, and brushite. Acid-base reaction was confirmed by the appearance of stretching peaks in IR spectra of set cements. SEM revealed rod-like crystals and platy crystals. Setting time of cements was 5–12 min. Type III showed significantly higher strength values compared to control. Type III yielded high biocompatibility. Conclusions. Type III CPCs show promise for dental applications. PMID:21941551

  3. Transcutaneous bowel sonography for inflammatory bowel disease is sensitive and specific when performed in a nonexpert low-volume North American center.

    PubMed

    Sey, Michael Sai Lai; Gregor, Jamie; Chande, Nilesh; Ponich, Terry; Bhaduri, Mousumi; Lum, Andrea; Zaleski, Witek; Yan, Brian

    2013-08-01

    Transcutaneous bowel sonography is a nonionizing imaging modality used in inflammatory bowel disease. Although available in Europe, its uptake in North America has been limited. Since the accuracy of bowel sonography is highly operator dependent, low-volume centers in North America may not achieve the same diagnostic accuracy reported in the European literature. Our objective was to determine the diagnostic accuracy of bowel sonography in a nonexpert low-volume center. All cases of bowel sonography at a single tertiary care center during an 18-month period were reviewed. Bowel sonography was compared with reference standards, including small-bowel follow-through, computed tomography, magnetic resonance imaging, colonoscopy, and surgical findings. A total of 103 cases were included for analysis during the study period. The final diagnoses included Crohn disease (72), ulcerative colitis (8), hemolytic uremic syndrome (1), and normal (22). The sensitivity and specificity of bowel sonography for intestinal wall inflammation were 87.8% and 92.6%, respectively. In the subset of patients who had complications of Crohn disease, the sensitivity and specificity were 50% and 100% for fistulas and 14% and 100% for strictures. One patient had an abscess, which was detected by bowel sonography. Abnormal bowel sonographic findings contributed to the escalation of treatment in 55% of cases. Bowel sonography for inflammatory bowel disease can be performed in low-volume centers and provides diagnostic accuracy for luminal disease comparable with published data, although it is less sensitive for complications of Crohn disease.

  4. Ultrasonic enhancing amorphization during synthesis of calcium phosphate.

    PubMed

    He, Kun; Xiao, Gui-Yong; Xu, Wen-Hua; Zhu, Rui-Fu; Lu, Yu-Peng

    2014-03-01

    Amorphous calcium phosphate (ACP) has great application potential in biomaterials field due to its non-cytotoxicity, high bioactivity, good cytocompatibility, and so on. The results of this research demonstrated that ultrasonic obviously enhanced amorphization during synthesis of calcium phosphate. The ACP phase was relatively ideal when the solvent of Ca(NO3)2·4H2O was ethanol and the solvent of (NH4)2HPO4 was a mixture of water and ethanol, under ultrasonic. In-situ crystallization of ACP could be observed by HRTEM. The mechanism on the effects of ultrasonic on amorphization of the synthesized calcium phosphate was discussed. It was suggested that ultrasonic synthesis might be a facile method to prepare pure and safe ACP related biomaterials. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Phosphate removal from aqueous solutions using raw and activated red mud and fly ash.

    PubMed

    Li, Yanzhong; Liu, Changjun; Luan, Zhaokun; Peng, Xianjia; Zhu, Chunlei; Chen, Zhaoyang; Zhang, Zhongguo; Fan, Jinghua; Jia, Zhiping

    2006-09-01

    The effect of acidification and heat treatment of raw red mud (RM) and fly ash (FA) on the sorption of phosphate was studied in parallel experiments. The result shows that a higher efficiency of phosphate removal was acquired by the activated samples than by the raw ones. The sample prepared by using the RM stirred with 0.25 M HCl for 2h (RM0.25), as well as another sample prepared by heating the RM at 700 degrees C for 2h (RM700), registered the maximum removal of phosphate (99% removal of phosphate). This occurred when they were used in the phosphate sorption studies conducted at pH 7.0 and 25 degrees C with the initial PO(4)(3-) concentration of 155 mg P/l. The FA samples treated in the same way described above can achieve 7.0 and 8.2 mg P/l phosphate removal for FA0.25 and FA700 respectively, corresponding to 45.2% and 52.9% removal. The activated materials performed higher phosphate removal over broader pH range compared with the raw ones. The influences of various factors, such as initial pH and initial phosphate concentration on the sorption capacity were also studied in batch equilibration technique. Solution pH significantly influenced the sorption. Each sample achieved the maximal removal of phosphate at pH 7.0. The amount of phosphate removal increased with the solute concentration. The Freundlich and Langmuir models were used to simulate the sorption equilibrium. The results indicate that the Langmuir model has a better correlation with the experimental data than the Freundlich model.

  6. Volvulus of the Small Bowel and Colon

    PubMed Central

    Kapadia, Muneera R.

    2017-01-01

    Volvulus of the intestines may involve either the small bowel or colon. In the pediatric population, small bowel volvulus is more common, while in the adult population, colonic volvulus is more often seen. The two most common types of colonic volvulus include sigmoid and cecal volvulus. Prompt diagnosis and treatment is imperative, otherwise bowel ischemia may ensue. Treatment often involves emergent surgical exploration and bowel resection. PMID:28144211

  7. Phosphate-Induced Immobilization of Uranium in Hanford Sediments.

    PubMed

    Pan, Zezhen; Giammar, Daniel E; Mehta, Vrajesh; Troyer, Lyndsay D; Catalano, Jeffrey G; Wang, Zheming

    2016-12-20

    Phosphate can be added to subsurface environments to immobilize U(VI) contamination. The efficacy of immobilization depends on the site-specific groundwater chemistry and aquifer sediment properties. Batch and column experiments were performed with sediments from the Hanford 300 Area in Washington State and artificial groundwater prepared to emulate the conditions at the site. Batch experiments revealed enhanced U(VI) sorption with increasing phosphate addition. X-ray absorption spectroscopy measurements of samples from the batch experiments found that U(VI) was predominantly adsorbed at conditions relevant to the column experiments and most field sites (low U(VI) loadings, <25 μM), and U(VI) phosphate precipitation occurred only at high initial U(VI) (>25 μM) and phosphate loadings. While batch experiments showed the transition of U(VI) uptake from adsorption to precipitation, the column study was more directly relevant to the subsurface environment because of the high solid:water ratio in the column and the advective flow of water. In column experiments, nearly six times more U(VI) was retained in sediments when phosphate-containing groundwater was introduced to U(VI)-loaded sediments than when the groundwater did not contain phosphate. This enhanced retention persisted for at least one month after cessation of phosphate addition to the influent fluid. Sequential extractions and laser-induced fluorescence spectroscopy of sediments from the columns suggested that the retained U(VI) was primarily in adsorbed forms. These results indicate that in situ remediation of groundwater by phosphate addition provides lasting benefit beyond the treatment period via enhanced U(VI) adsorption to sediments.

  8. Addition of senna improves quality of colonoscopy preparation with magnesium citrate.

    PubMed

    Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara

    2009-04-14

    To prospectively investigate the effectiveness and patient's tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome.

  9. Efficacy of tooth whitening with different calcium phosphate-based formulations.

    PubMed

    Jin, Jian; Xu, Xiaohui; Lai, Guangyun; Kunzelmann, Karl-Heinz

    2013-08-01

    The aim of this in-vitro study was to evaluate the efficacy of tooth whitening using different calcium phosphate-based formulations. Teeth were treated with three different hydroxyapatite preparations at different concentrations and with two control preparations; each tooth was treated a total of three times. After application of the last material, hydrodynamic shear force was applied to mimic mechanical loading. After each treatment, tooth color was measured using a dental spectrophotometer, and the mean changes in L*a*b* values between different measurements were expressed as ∆E. The results indicated significant differences between the materials, but neither dose- nor time-dependent associations were found. The suspension containing tricalcium phosphate (10 wt%) showed the most obvious color change (∆E = 2.20 ± 0.90), while the suspension containing zinc-carbonate-apatite (20 wt%) showed the least obvious color change (∆E = 0.91 ± 0.50). Calcium phosphate-based formulations that can adhere to the enamel surface and contribute to tooth whitening have promising tooth-whitening potential. © 2013 Eur J Oral Sci.

  10. Macroporous Calcium Phosphate/Chitosan Composites Prepared via Unidirectional Ice Segregation and Subsequent Freeze-Drying

    PubMed Central

    Aranaz, Inmaculada; Martínez-Campos, Enrique; Moreno-Vicente, Carolina; Civantos, Ana; García-Arguelles, Sara; del Monte, Francisco

    2017-01-01

    Calcium phosphate chitosan-based composites have gained much interest in recent years for biomedical purposes. In this paper, three-dimensional calcium phosphate chitosan-based composites with different mineral contents were produced using a green method called ice segregation induced self-assembly (ISISA). In this methodology, ice crystals were used as a template to produce porous structures from an aqueous solution of chitosan (CS) and hydroxyapatite (Hap) also containing acetic acid (pH = 4.5). For better characterization of the nature of the inorganic matter entrapped within the resulting composite, we performed either oxygen plasma or calcination processes to remove the organic matter. The nature of the phosphate salts was studied by XRD and NMR studies. Amorphous calcium phosphate (ACP) was identified as the mineral phase in the composites submitted to oxygen plasma, whereas crystalline Hap was obtained after calcination. SEM microscopy revealed the formation of porous structures (porosity around 80–85%) in the original composites, as well as in the inorganic matrices obtained after calcination, with porous channels of up to 50 µm in diameter in the former case and of up to 20 µm in the latter. The biocompatibility of the composites was assessed using two different cell lines: C2C12GFP premyoblastic cells and MC3T3 preosteoblastic cells. PMID:28772874

  11. Neurogenic bowel management after spinal cord injury: Malaysian experience.

    PubMed

    Engkasan, Julia Patrick; Sudin, Siti Suhaida

    2013-02-01

    To describe the bowel programmes utilized by individuals with spinal cord injury; and to determine the association between the outcome of the bowel programmes and various interventions to facilitate defecation. A cross-sectional study. Individuals with spinal cord injury who have neurogenic bowel dysfunction. Face-to-face interviews were conducted using a self-constructed questionnaire that consisted of: (i) demographic and clinical characteristics of the participants; (ii) interventions to facilitate defecation; (iii) bowel care practices; (iv) outcome of the bowel programme (incidence of incontinence and duration of the evacuation procedure); and (v) participant satisfaction with their bowel programme. The majority (79.2%) of subjects used multiple interventions for bowel care. Duration of the evacuation procedure was more than 60 min in 28.0% of participants. Water intake of more than 2 l/day was associated with longer duration of bowel care. Only 8.0% of participants had at least one episode of incontinence per month. The majority of participants (84.8%) were satisfied with their bowel programme. Patients used multiple interventions to manage their bowels and spent a substantial amount of time performing bowel care. Nevertheless, the incidence of incontinence was low and satisfaction with their bowel programme was high.

  12. A Comparison of Patient Outcomes and Quality of Life in Persons With Neurogenic Bowel: Standard Bowel Care Program Vs Colostomy

    PubMed Central

    Luther, Stephen L; Nelson, Audrey L; Harrow, Jeffrey J; Chen, Fangfei; Goetz, Lance L

    2005-01-01

    Background/Objective: The purpose of this study was to compare patient outcomes and quality of life for people with neurogenic bowel using either a standard bowel care program or colostomy. Methods: We analyzed survey data from a national sample, comparing outcomes between veterans with spinal cord injury (SCI) who perform bowel care programs vs individuals with colostomies. This study is part of a larger study to evaluate clinical practice guideline implementation in SCI. The sample included 1,503 veterans with SCI. The response rate was 58.4%. For comparison, we matched the respondents with colostomies to matched controls from the remainder of the survey cohort. A total of 74 veterans with SCI and colostomies were matched with 296 controls, using propensity scores. Seven items were designed to elicit information about the respondent's satisfaction with their bowel care program, whereas 7 other items were designed to measure bowel-related quality of life. Results: No statistically significant differences in satisfaction or quality of life were found between the responses from veterans with colostomies and those with traditional bowel care programs. Both respondents with colostomies and those without colostomies indicated that they had received training for their bowel care program, that they experienced relatively few complications, such as falls as a result of their bowel care program, and that their quality of life related to bowel care was generally good. However, large numbers of respondents with colostomies (n = 39; 55.7%) and without colostomies (n = 113; 41.7%) reported that they were very unsatisfied with their bowel care program. Conclusion: Satisfaction with bowel care is a major problem for veterans with SCI. PMID:16869085

  13. In Vitro Degradation Behaviors of Manganese-Calcium Phosphate Coatings on an Mg-Ca-Zn Alloy

    PubMed Central

    Su, Yichang; Su, Yingchao; Zai, Wei

    2018-01-01

    In order to decrease the degradation rate of magnesium (Mg) alloys for the potential orthopedic applications, manganese-calcium phosphate coatings were prepared on an Mg-Ca-Zn alloy in calcium phosphating solutions with different addition of Mn2+. Influence of Mn content on degradation behaviors of phosphate coatings in the simulated body fluid was investigated to obtain the optimum coating. With the increasing Mn addition, the corrosion resistance of the manganese-calcium phosphate coatings was gradually improved. The optimum coating prepared in solution containing 0.05 mol/L Mn2+ had a uniform and compact microstructure and was composed of MnHPO4·3H2O, CaHPO4·2H2O, and Ca3(PO4)2. The electrochemical corrosion test in simulated body fluid revealed that polarization resistance of the optimum coating is 36273 Ωcm2, which is about 11 times higher than that of phosphate coating without Mn addition. The optimum coating also showed the most stable surface structure and lowest hydrogen release in the immersion test in simulated body fluid. PMID:29643970

  14. Does stress induce bowel dysfunction?

    PubMed

    Chang, Yu-Ming; El-Zaatari, Mohamad; Kao, John Y

    2014-08-01

    Psychological stress is known to induce somatic symptoms. Classically, many gut physiological responses to stress are mediated by the hypothalamus-pituitary-adrenal axis. There is, however, a growing body of evidence of stress-induced corticotrophin-releasing factor (CRF) release causing bowel dysfunction through multiple pathways, either through the HPA axis, the autonomic nervous systems, or directly on the bowel itself. In addition, recent findings of CRF influencing the composition of gut microbiota lend support for the use of probiotics, antibiotics, and other microbiota-altering agents as potential therapeutic measures in stress-induced bowel dysfunction.

  15. In Vitro Release and Bioavailability of Silybin from Micelle-Templated Porous Calcium Phosphate Microparticles.

    PubMed

    Zhu, Yuan; Wang, Miaomiao; Zhang, Ya; Zeng, Jin; Omari-Siaw, E; Yu, Jiangnan; Xu, Ximing

    2016-10-01

    Developing a promising carrier for the delivery of poorly water-soluble drugs, such as silybin, to improve oral absorption has become a very worthy of consideration. The goal of this study was to prepare a novel porous calcium phosphate microparticle using povidone-mixed micelles as template while evaluating its in vitro and in vivo properties with silybin as a model drug. The particle characterization, in vitro drug release behavior, and pharmacokinetic parameters of the prepared silybin-loaded calcium phosphate microparticle were investigated. The mean particle size was found to be 3.54 ± 0.32 μm with a rough surface porous structure. Additionally, the silybin-loaded calcium phosphate microparticle compared with the free silybin showed a prolonged 72-h release in vitro and a higher C max (418.5 ± 23.7 ng mL(-1)) with 167.5% oral relative bioavailability. A level A in vitro-in vivo correlation (IVIVC), established for the first time, demonstrated an excellent IVIVC of the formulated silybin in oral administration. In conclusion, this povidone-mixed micelle-based microparticle was successfully prepared to enhance the oral bioavailability of silybin. Therefore, application of this novel porous calcium phosphate microparticle holds a significant potential for the development of poorly water-soluble drugs.

  16. Research on preparation of phosphate-modified animal glue binder for foundry use

    NASA Astrophysics Data System (ADS)

    Wang, Tian-Shu; Liu, Wei-Hua; Li, Ying-Min

    2018-03-01

    In this paper, three phosphates were used as modifiers to modify animal glue binder. The structural characteristics and thermal properties of animal glue binder treated with phosphates were studied by Fourier transform-infrared spectroscopy, gel permeation chromatography and derivative thermogravimetric analysis. The results showed that the modified animal glue binder had better sand tensile strength and lower viscosity than untreated animal glue binder. The best modification process was as follows: the optimal amount of sodium carbonate was 4 wt% to animal glue; the optimal weight ratio of the modifiers was sodium pyrophosphate : sodium tripolyphosphate : sodium hexametaphosphate : animal glue = 3 : 3 : 4 : 100, and the optimal reaction should be performed at 80°C for a reaction time of 120 min. A final tensile strength of approximately 3.20 MPa was achieved and the viscosity value was approximately 880 mPa s.

  17. Irritable bowel syndrome in quiescent inflammatory bowel disease: a review.

    PubMed

    Burgell, R E; Asthana, A K; Gibson, P R

    2015-12-01

    Ongoing troublesome bowel symptoms despite quiescent inflammatory disease are a frequent management challenge when caring for patients with inflammatory bowel disease (IBD). Even when active disease has been excluded the prevalence of residual gastrointestinal symptoms is surprisingly high and the cause often obscure. The presence of a concurrent functional disorder such as irritable bowel syndrome (IBS) is associated with worse quality of life, worse physical functioning, higher prevalence of anxiety and greater health care utilization. Potential etiological mechanisms leading to the development of IBS like symptoms include the development of visceral hypersensitivity following the original inflammatory insult, alteration in cortical processing, dysbiosis and residual subacute inflammation. Therapeutic options for managing IBS in patients with IBD include dietary modification, interventions targeted at correction of visceral sensory dysfunction or cortical processing and modulation of the gut microbiota. As there are few studies specifically examining the treatment of IBS in patients with IBD, the majority of therapeutic interventions are extrapolated from the IBS literature. Given the frequency of residual functional symptoms in IBS, significantly more research is warranted in this field.

  18. Defining and diagnosing irritable bowel syndrome.

    PubMed

    Schuster, M M

    2001-07-01

    Approximately 20% of the general population has irritable bowel syndrome (IBS). Although the majority of these individuals do not consult a physician, IBS accounts for 25% of visits to a gastroenterologist and up to 12% of visits to a primary care physician. Consequently, the direct and indirect costs associated with IBS are estimated at $8 billion annually. IBS symptoms, with no apparent structural pathology, include altered bowel habits, abdominal pain/discomfort, and bloating. The Rome II criteria, a standardized guideline for the diagnosis of IBS, contains in its definition abdominal pain or discomfort associated with altered bowel habits. Bloating may often be present. Three patient subgroups are defined according to the predominant bowel symptom: constipation, diarrhea, or alternating constipation and diarrhea. Hematology, fecal occult blood test, flexible sigmoidoscopy, and lactose intolerance evaluations are recommended for all patients demonstrating symptoms of IBS. When indicated, tests are recommended to rule out bacterial or parasitic infections, pelvic floor muscle dyssynergia, colonic inertia, peptic ulcer, or inflammatory bowel disease.

  19. Preferable adsorption of phosphate using lanthanum-incorporated porous zeolite: Characteristics and mechanism

    NASA Astrophysics Data System (ADS)

    He, Yinhai; Lin, Hai; Dong, Yingbo; Wang, Liang

    2017-12-01

    The adsorbent, where lanthanum oxide was incorporated onto porous zeolite (La-Z), of preferable adsorption towards phosphate was prepared by hydrothermal synthesis. Based on pH effect results, La-Z would effectively sequestrate phosphate over wider pH range of 3.0-7.0, alkaline conditions were unfavorable for phosphate. The adsorption of phosphate was not significantly influenced by ionic strength and by coexisting anions of chloride, nitrate and sulfate but bicarbonate showed slightly greater negative effects, indicating La-Z possessed highly selectivity to phosphate. Adsorption of phosphate could be well fitted by pseudo-second-order model and the process was mainly controlled by intra-particle diffusion. Equilibrium adsorption demonstrated that Langmuir model was more suitable than Freundlich model for description phosphate adsorption and the adsorption capacity was 17.2 mg P g-1, which exhibited 95% utilization of incorporated La. Over 95% phosphate was eliminated in real effluent treatment when the dose was 2 g L-1. The underlying mechanism for phosphate capture was probed with Zeta potential and X-ray photoelectron spectroscope analysis, and the formation of La-P inner-sphere complexation was testified to be the dominant pathway. All the results suggested that the porous zeolite-supported lanthanum oxide can serve as a promising adsorbent for phosphate removal in realistic application.

  20. Metal Phosphides and Phosphates-based Electrodes for Electrochemical Supercapacitors.

    PubMed

    Li, Xin; Elshahawy, Abdelnaby M; Guan, Cao; Wang, John

    2017-10-01

    Phosphorus compounds, such as metal phosphides and phosphates have shown excellent performances and great potential in electrochemical energy storage, which are demonstrated by research works published in recent years. Some of these metal phosphides and phosphates and their hybrids compare favorably with transition metal oxides/hydroxides, which have been studied extensively as a class of electrode materials for supercapacitor applications, where they have limitations in terms of electrical and ion conductivity and device stability. To be specific, metal phosphides have both metalloid characteristics and good electric conductivity. For metal phosphates, the open-framework structures with large channels and cavities endow them with good ion conductivity and charge storage capacity. In this review, we present the recent progress on metal phosphides and phosphates, by focusing on their advantages/disadvantages and potential applications as a new class of electrode materials in supercapacitors. The synthesis methods to prepare these metal phosphides/phosphates are looked into, together with the scientific insights involved, as they strongly affect the electrochemical energy storage performance. Particular attentions are paid to those hybrid-type materials, where strong synergistic effects exist. In the summary, the future perspectives and challenges for the metal phosphides, phosphates and hybrid-types are proposed and discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Alkaline resistant phosphate glasses and method of preparation and use thereof

    DOEpatents

    Brow, Richard K.; Reis, Signo T.; Velez, Mariano; Day, Delbert E.

    2010-01-26

    A substantially alkaline resistant calcium-iron-phosphate (CFP) glass and methods of making and using thereof. In one application, the CFP glass is drawn into a fiber and dispersed in cement to produce glass fiber reinforced concrete (GFRC) articles having the high compressive strength of concrete with the high impact, flexural and tensile strength associated with glass fibers.

  2. Phosphate-Induced Immobilization of Uranium in Hanford Sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Zezhen; Giammar, Daniel E.; Mehta, Vrajesh

    2016-12-20

    Phosphate can be added to subsurface environments to immobilize U(VI) contamination. The efficacy of immobilization depends on the site-specific groundwater chemistry and aquifer sediment properties. Batch and column experiments were performed with sediments from the Hanford 300 Area in Washington State and artificial groundwater prepared to emulate the conditions at the site. Batch experiments revealed enhanced U(VI) sorption with increasing phosphate addition. X-ray absorption spectroscopy measurements of samples from the batch experiments found that U(VI) was predominantly adsorbed at conditions relevant to the column experiments and most field sites (low U(VI) loadings, <25 μM), and U(VI) phosphate precipitation occurred onlymore » at high initial U(VI) (>25 μM) and phosphate loadings. While batch experiments showed the transition of U(VI) uptake from adsorption to precipitation, the column study was more directly relevant to the subsurface environment because of the high solid:water ratio in the column and the advective flow of water. In column experiments, nearly six times more U(VI) was retained in sediments when phosphate-containing groundwater was introduced to U(VI)-loaded sediments than when the groundwater did not contain phosphate. This enhanced retention persisted for at least one month after cessation of phosphate addition to the influent fluid. Sequential extractions and laser-induced fluorescence spectroscopy of sediments from the columns suggested that the retained U(VI) was primarily in adsorbed forms. These results indicate that in situ remediation of groundwater by phosphate addition provides lasting benefit beyond the treatment period via enhanced U(VI) adsorption to sediments.« less

  3. Phosphate-Induced Immobilization of Uranium in Hanford Sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Zezhen; Giammar, Daniel E.; Mehta, Vrajesh

    2016-12-20

    Phosphate can be added to subsurface environments to immobilize U(VI) contamination. The efficacy of immobilization depends on the site-specific groundwater chemistry and aquifer sediment properties. Batch and column experiments were performed with sediments from the Hanford 300 Area in Washington State and artificial groundwater prepared to emulate the conditions at the site. Batch experiments revealed enhanced U(VI) sorption with increasing phosphate addition. X-ray absorption spectroscopy measurements of samples from the batch experiments found that U(VI) was predominantly adsorbed at conditions relevant to the column experiments and most field sites (low U(VI) loadings, <25 μM), and U(VI) phosphate precipitation occurred onlymore » at high initial U(VI) (>25μM) and phosphate loadings. While batch experiments showed the transition of U(VI) uptake from adsorption to precipitation, the column study was more directly relevant to the subsurface environment because of the high solid:water ratio in the column and the advective flow of water. In column experiments, nearly six times more U(VI) was retained in sediments when phosphate-containing groundwater was introduced to U(VI)-loaded sediments than when the groundwater did not contain phosphate. This enhanced retention persisted for at least one month after cessation of phosphate addition to the influent fluid. Sequential extractions and laser-induced fluorescence spectroscopy of sediments from the columns suggested that the retained U(VI) was primarily in adsorbed forms. These results indicate that in situ remediation of groundwater by phosphate addition provides lasting benefit beyond the treatment period via enhanced U(VI) adsorption to sediments.« less

  4. NMR spectroscopic study of organic phosphate esters coprecipitated with calcite

    NASA Astrophysics Data System (ADS)

    Phillips, Brian L.; Zhang, Zelong; Kubista, Laura; Frisia, Silvia; Borsato, Andrea

    2016-06-01

    Organic phosphorus incorporated in calcite during laboratory precipitation experiments and in natural cave deposits was investigated by solid-state NMR spectroscopy. For calcite precipitated in the presence of organic phosphoesters of varying size and functionality, solid-state 31P{1H} CP/MAS NMR shows that the phosphoesters were incorporated intact into the solid. Systematic changes in the 31P NMR chemical shift of the phosphate group were observed between the solid phosphoester and that incorporated in the solid precipitate, yielding 31P NMR chemical shifts of the coprecipitates in the range of +1.8 to -2.2 ppm. These chemical shifts are distinct from that of similarly prepared calcite coprecipitated with inorganic phosphate, 3.5 ppm. Only minor changes were noted in the phosphoester 31P chemical shift anisotropy (CSA) which suggests no significant change in the local structure of the phosphate group, which is dominated by C-O-P bonding. Close spatial proximity of the organic phosphate group to calcite structural components was revealed by 31P/13C rotational echo double resonance (REDOR) experiments for coprecipitates prepared with 13C-labeled carbonate. All coprecipitates showed significant 31P dephasing effects upon 13C-irradiation, signaling atomic-scale proximity to carbonate carbon. The dephasing rate for smaller organophosphate molecules is similar to that observed for inorganic phosphate, whereas much slower dephasing was observed for larger molecules having long and/or bulky side-chains. This result suggests that small organic molecules can be tightly enclosed within the calcite structure, whereas significant structural disruption required to accommodate the larger organic molecules leads to longer phosphate-carbonate distances. Comparison of 31P NMR spectroscopic data from the synthetic coprecipitates with those from calcite moonmilk speleothems indicates that phosphorus occurs mainly as inorganic orthophosphate in the natural deposits, although small

  5. Irritable bowel syndrome: contemporary nutrition management strategies.

    PubMed

    Mullin, Gerard E; Shepherd, Sue J; Chander Roland, Bani; Ireton-Jones, Carol; Matarese, Laura E

    2014-09-01

    Irritable bowel syndrome is a complex disorder whose pathophysiology involves alterations in the enteric microbiota, visceral hypersensitivity, gut immune/barrier function, hypothalamic-pituitary-adrenal axis regulation, neurotransmitters, stress response, psychological factors, and more. The importance of diet in the management of irritable bowel syndrome has taken center stage in recent times as the literature validates the relationship of certain foods with the provocation of symptoms. Likewise, a number of elimination dietary programs have been successful in alleviating irritable bowel syndrome symptoms. Knowledge of the dietary management strategies for irritable bowel syndrome will help guide nutritionists and healthcare practitioners to deliver optimal outcomes. This tutorial reviews the nutrition management strategies for irritable bowel syndrome. © 2014 American Society for Parenteral and Enteral Nutrition.

  6. Large bowel injuries during gynecological laparoscopy.

    PubMed

    Ulker, Kahraman; Anuk, Turgut; Bozkurt, Murat; Karasu, Yetkin

    2014-12-16

    Laparoscopy is one of the most frequently preferred surgical options in gynecological surgery and has advantages over laparotomy, including smaller surgical scars, faster recovery, less pain and earlier return of bowel functions. Generally, it is also accepted as safe and effective and patients tolerate it well. However, it is still an intra-abdominal procedure and has the similar potential risks of laparotomy, including injury of a vital structure, bleeding and infection. Besides the well-known risks of open surgery, laparoscopy also has its own unique risks related to abdominal access methods, pneumoperitoneum created to provide adequate operative space and the energy modalities used during the procedures. Bowel, bladder or major blood vessel injuries and passage of gas into the intravascular space may result from laparoscopic surgical technique. In addition, the risks of aspiration, respiratory dysfunction and cardiovascular dysfunction increase during laparoscopy. Large bowel injuries during laparoscopy are serious complications because 50% of bowel injuries and 60% of visceral injuries are undiagnosed at the time of primary surgery. A missed or delayed diagnosis increases the risk of bowel perforation and consequently sepsis and even death. In this paper, we aim to focus on large bowel injuries that happen during gynecological laparoscopy and review their diagnostic and management options.

  7. Small-bowel capsule endoscopy: A ten-point contemporary review

    PubMed Central

    Koulaouzidis, Anastasios; Rondonotti, Emanuele; Karargyris, Alexandros

    2013-01-01

    The introduction of capsule endoscopy (CE) in clinical practice increased the interest for the study of the small-bowel. Consequently, in about 10 years, an impressive quantity of literature on indications, diagnostic yield (DY), safety profile and technical evolution of CE has been published as well as several reviews. At present time, there are 5 small-bowel capsule enteroscopy (SBCE) models in the worldwide market. Head-to-head trials have showed in the great majority of studies comparable results in terms of DY, image quality and completion rate. CE meta-analyses formed the basis of national/international guidelines; these guidelines place CE in a prime position for the diagnostic work-up of patients with obscure gastrointestinal bleeding, known and/or suspected Crohn’s disease and possible small-bowel neoplasia. A 2-L polyethylene glycol-based purge, administered the day before the procedure, is the most widely practiced preparation regimen. Whether this regimen can be further improved (i.e., by further decreasing its volume, changing the timing of administration, coupling it with prokinetics and/or other factors) or if it can really affect the DY, is still under discussion. Faecal calprotectin has been used in SBCE studies in two settings: in patients taking non-steroidal anti-inflammatory drugs, to evaluate the type and extent of mucosal damage and, more importantly from a clinical point of view, in patients with known or suspected Crohn’s disease for assessment of inflammation activity. Although there is still a lot of debate around the exact reasons of SBCE poor performance in various small-bowel segments, it is worth to remember that the capsule progress is non-steerable, hence more rapid in the proximal than in lower segments of the small-bowel. Capsule aspiration, a relatively unexpected complication, has been reported with increasing frequency. This is probably related with the increase in the mean age of patients undergoing CE. CE video review is

  8. Bowel perforation detection using metabolic fluorescent chlorophylls

    NASA Astrophysics Data System (ADS)

    Han, Jung Hyun; Jo, Young Goun; Kim, Jung Chul; Choi, Sujeong; Kang, Hoonsoo; Kim, Yong-Chul; Hwang, In-Wook

    2016-03-01

    Thus far, there have been tries of detection of disease using fluorescent materials. We introduce the chlorophyll derivatives from food plants, which have longer-wavelength emissions (at >650 nm) than those of fluorescence of tissues and organs, for detection of bowel perforation. To figure out the possibility of fluorescence spectroscopy as a monitoring sensor of bowel perforation, fluorescence from organs of rodent models, intestinal and peritoneal fluids of rodent models and human were analyzed. In IVIS fluorescence image of rodent abdominal organ, visualization of perforated area only was possible when threshold of image is extremely finely controlled. Generally, both perforated area of bowel and normal bowel which filled with large amount of chlorophyll derivatives were visualized with fluorescence. The fluorescence from chlorophyll derivatives penetrated through the normal bowel wall makes difficult to distinguish perforation area from normal bowel with direct visualization of fluorescence. However, intestinal fluids containing chlorophyll derivatives from food contents can leak from perforation sites in situation of bowel perforation. It may show brighter and longer-wavelength regime emissions of chlorophyll derivatives than those of pure peritoneal fluid or bioorgans. Peritoneal fluid mixed with intestinal fluids show much brighter emissions in longer wavelength (at>650 nm) than those of pure peritoneal fluid. In addition, irrigation fluid, which is used for the cleansing of organ and peritoneal cavity, made of mixed intestinal and peritoneal fluid diluted with physiologic saline also can be monitored bowel perforation during surgery.

  9. Final Report - Assessment of Potential Phosphate Ion-Cementitious Materials Interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naus, Dan J; Mattus, Catherine H; Dole, Leslie Robert

    The objectives of this limited study were to: (1) review the potential for degradation of cementitious materials due to exposure to high concentrations of phosphate ions; (2) provide an improved understanding of any significant factors that may lead to a requirement to establish exposure limits for concrete structures exposed to soils or ground waters containing high levels of phosphate ions; (3) recommend, as appropriate, whether a limitation on phosphate ion concentration in soils or ground water is required to avoid degradation of concrete structures; and (4) provide a "primer" on factors that can affect the durability of concrete materials andmore » structures in nuclear power plants. An assessment of the potential effects of phosphate ions on cementitious materials was made through a review of the literature, contacts with concrete research personnel, and conduct of a "bench-scale" laboratory investigation. Results of these activities indicate that: no harmful interactions occur between phosphates and cementitious materials unless phosphates are present in the form of phosphoric acid; phosphates have been incorporated into concrete as set retarders, and phosphate cements have been used for infrastructure repair; no standards or guidelines exist pertaining to applications of reinforced concrete structures in high-phosphate environments; interactions of phosphate ions and cementitious materials has not been a concern of the research community; and laboratory results indicate similar performance of specimens cured in phosphate solutions and those cured in a calcium hydroxide solution after exposure periods of up to eighteen months. Relative to the "primer," a separate NUREG report has been prepared that provides a review of pertinent factors that can affect the durability of nuclear power plant reinforced concrete structures.« less

  10. Surgical treatment of complex small bowel Crohn disease.

    PubMed

    Michelassi, Fabrizio; Sultan, Samuel

    2014-08-01

    The clinical presentations of Crohn disease of the small bowel vary from low to high complexity. Understanding the complexity of Crohn disease of the small bowel is important for the surgeon and the gastroenterologist caring for the patient and may be relevant for clinical research as a way to compare outcomes. Here, we present a categorization of complex small bowel Crohn disease and review its surgical treatment as a potential initial step toward the establishment of a definition of complex disease. The complexity of small bowel Crohn disease can be sorted into several categories: technical challenges, namely, fistulae, abscesses, bowel or ureteral obstruction, hemorrhage, cancer and thickened mesentery; extensive disease; the presence of short gut; a history of prolonged use of medications, particularly steroids, immunomodulators, and biological agents; and a high risk of recurrence. Although the principles of modern surgical treatment of Crohn disease have evolved to bowel conservation such as strictureplasty techniques and limited resection margins, such practices by themselves are often not sufficient for the management of complex small bowel Crohn disease. This manuscript reviews each category of complex small bowel Crohn disease, with special emphasis on appropriate surgical strategy.

  11. Bowel resection for deep endometriosis: a systematic review.

    PubMed

    De Cicco, C; Corona, R; Schonman, R; Mailova, K; Ussia, A; Koninckx, Pr

    2011-02-01

    deep endometriosis involving the bowel often is treated by segmental bowel resection. In a recent review of over 10000 segmental bowel resections for indications other than endometriosis, low rectum resections, in particular, were associated with a high long-term complication rate for bladder, bowel and sexual function. to review systematically segmental bowel resections for endometriosis for indications, outcome and complications according to the level of resection and the volume of the nodule. all published articles on segmental bowel resection for endometriosis identified through MEDLINE, EMBASE and ISI Web of Knowledge databases during 1997-2009. the terms 'bowel', 'rectal', 'colorectal', 'rectovaginal', 'rectosigmoid', 'resection' and 'endometriosis' were used. Articles describing more than five bowel resections for endometriosis, and with details of at least three of the relevant endpoints. data did not permit a meaningful meta-analysis. thirty-four articles were found describing 1889 bowel resections. The level of bowel resection and the size of the lesions were poorly reported. The indications to perform a bowel resection were variable and were rarely described accurately. The duration of surgery varied widely and endometriosis was not always confirmed by pathology. Although not recorded prospectively, pain relief was systematically reported as excellent for the first year after surgery. Recurrence of pain was reported in 45 of 189 women; recurrence requiring reintervention occurred in 61 of 314 women. Recurrence of endometriosis was reported in 37 of 267 women. The complication rate was comparable with that of bowel resection for indications other than endometriosis. Data on sexual function were not found. after a systematic review, it was found that the indication to perform a segmental resection was poorly documented and the data did not permit an analysis of indication and outcome according to localisation or diameter of the endometriotic nodule

  12. Addition of senna improves quality of colonoscopy preparation with magnesium citrate

    PubMed Central

    Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara

    2009-01-01

    AIM: To prospectively investigate the effectiveness and patient’s tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. METHODS: A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. RESULTS: The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). CONCLUSION: The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome. PMID:19360920

  13. Globalisation of inflammatory bowel disease: perspectives from the evolution of inflammatory bowel disease in the UK and China.

    PubMed

    Kaplan, Gilaad G; Ng, Siew C

    2016-12-01

    The UK and China provide unique historical perspectives on the evolution of the incidence of inflammatory bowel disease, which might provide insight into its pathogenesis. Historical records from the UK document the emergence of ulcerative colitis during the mid-1800s, which was later followed by the recognition of Crohn's disease in 1932. During the second half of the 20th century, the incidence of inflammatory bowel disease rose dramatically in high-income countries. Globalisation at the turn of the 21st century led to rapid economic development of newly industrialised countries such as China. In China, the modernisation of society was accompanied by the recognition of a sharp rise in the incidence of inflammatory bowel disease. The prevalence of inflammatory bowel disease is expected to continue to rise in high-income countries and is also likely to accelerate in the developing world. An understanding of the shared and different environmental determinants underpinning the pathogenesis of inflammatory bowel disease in western and eastern countries is essential to implement interventions that will blunt the rising global burden of inflammatory bowel disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Dysregulation of phosphate metabolism and conditions associated with phosphate toxicity

    PubMed Central

    Brown, Ronald B; Razzaque, Mohammed S

    2015-01-01

    Phosphate homeostasis is coordinated and regulated by complex cross-organ talk through delicate hormonal networks. Parathyroid hormone (PTH), secreted in response to low serum calcium, has an important role in maintaining phosphate homeostasis by influencing renal synthesis of 1,25-dihydroxyvitamin D, thereby increasing intestinal phosphate absorption. Moreover, PTH can increase phosphate efflux from bone and contribute to renal phosphate homeostasis through phosphaturic effects. In addition, PTH can induce skeletal synthesis of another potent phosphaturic hormone, fibroblast growth factor 23 (FGF23), which is able to inhibit renal tubular phosphate reabsorption, thereby increasing urinary phosphate excretion. FGF23 can also fine-tune vitamin D homeostasis by suppressing renal expression of 1-alpha hydroxylase (1α(OH)ase). This review briefly discusses how FGF23, by forming a bone–kidney axis, regulates phosphate homeostasis, and how its dysregulation can lead to phosphate toxicity that induces widespread tissue injury. We also provide evidence to explain how phosphate toxicity related to dietary phosphorus overload may facilitate incidence of noncommunicable diseases including kidney disease, cardiovascular disease, cancers and skeletal disorders. PMID:26131357

  15. Effects of phosphates on microstructure and bioactivity of micro-arc oxidized calcium phosphate coatings on Mg-Zn-Zr magnesium alloy.

    PubMed

    Pan, Y K; Chen, C Z; Wang, D G; Zhao, T G

    2013-09-01

    Calcium phosphate (CaP) coatings were prepared on Mg-Zn-Zr magnesium alloy by micro-arc oxidation (MAO) in electrolyte containing calcium acetate monohydrate (CH3COO)2Ca·H2O) and different phosphates (i.e. disodium hydrogen phosphate dodecahydrate (Na2HPO4·12H2O), sodium phosphate (Na3PO4·H2O) and sodium hexametaphosphate((NaPO3)6)). Scanning electron microscope (SEM), energy-dispersive X-ray spectrometry (EDS) and X-ray diffractometer (XRD) were employed to characterize the microstructure, elemental distribution and phase composition of the CaP coatings. Simulated body fluid (SBF) immersion test was used to evaluate the coating bioactivity and degradability. Systemic toxicity test was used to evaluate the coating biocompatibility. Fluoride ion selective electrode (ISE) was used to measure F(-) ions concentration during 30 days SBF immersion. The CaP coatings effectively reduced the corrosion rate and the surfaces of CaP coatings were covered by a new layer formed of numerous needle-like and scale-like apatites. The formation of these calcium phosphate apatites indicates that the coatings have excellent bioactivity. The coatings formed in (NaPO3)6-containging electrolyte exhibit thicker thickness, higher adhesive strength, slower degradation rate, better apatite-inducing ability and biocompatibility. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Magnesium phosphate pentahydrate nanosheets: Microwave-hydrothermal rapid synthesis using creatine phosphate as an organic phosphorus source and application in protein adsorption.

    PubMed

    Qi, Chao; Zhu, Ying-Jie; Wu, Cheng-Tie; Sun, Tuan-Wei; Chen, Feng; Wu, Jin

    2016-01-15

    Magnesium phosphate materials have aroused interest of researchers in recent years and are promising for biomedical applications due to their good biocompatibility and biodegradability. In this work, we report the microwave-hydrothermal rapid synthesis of magnesium phosphate pentahydrate nanosheets (MPHSs) using biocompatible creatine phosphate as an organic phosphorus source. This method is facile, rapid, surfactant-free and environmentally friendly. The as-prepared MPHSs have an obvious pH-dependent dissolution performance which can be used as an ideal pH-responsive nanocarrier for drug and gene delivery. Moreover, the MPHSs have a good cytocompatibility and a high ability to promote osteoblast MC-3T3 adhesion and spreading, as well as a relatively high protein adsorption ability using hemoglobin (Hb) as a model protein. Thus, the MPHSs are promising for the applications in biomedical fields such as protein adsorption and bone regeneration. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Vincristine-sulphate-loaded liposome-templated calcium phosphate nanoshell as potential tumor-targeting delivery system.

    PubMed

    Thakkar, Hetal Paresh; Baser, Amit Kumar; Parmar, Mayur Prakashbhai; Patel, Ketul Harshadbhai; Ramachandra Murthy, Rayasa

    2012-06-01

    Vincristine-sulfate-loaded liposomes were prepared with an aim to improve stability, reduce drug leakage during systemic circulation, and increase intracellular uptake. Liposomes were prepared by the thin-film hydration method, followed by coating with calcium phosphate, using the sequential addition approach. Prepared formulations were characterized for size, zeta potential, drug-entrapment efficiency, morphology by transmission electron microscopy (TEM), in vitro drug-release profile, and in vitro cell cytotoxicity study. Effect of formulation variables, such as drug:lipid ratio as well as nature and volume of hydration media, were found to affect drug entrapment, and the concentration of calcium chloride in coating was found to affect size and coating efficiency. Size, zeta potential, and TEM images confirmed that the liposomes were effectively coated with calcium phosphate. The calcium phosphate nanoshell exhibited pH-dependent drug release, showing significantly lower release at pH 7.4, compared to the release at pH 4.5, which is the pH of the tumor interstitium. The in vitro cytotoxicity study done on the lung cancer cell line indicated that coated liposomes are more cytotoxic than plain liposomes and drug solution, indicating their potential for intracellular drug delivery. The cell-uptake study done on the lung cancer cell line indicated that calcium-phosphate-coated liposomes show higher cell uptake than uncoated liposomes.

  18. [Optimization of riboflavin sodium phosphate loading to calcium alginate floating microspheres by response surface methodology].

    PubMed

    Zhang, An-yang; Fan, Tian-yuan

    2009-12-18

    To investigate the preparation, optimization and in vitro properties of riboflavin sodium phosphate floating microspheres. The floating microspheres composed of riboflavin sodium phosphate and calcium alginate were prepared using ion gelatin-oven drying method. The properties of the microspheres were investigated, including the buoyancy, release, appearance and entrapment efficiency. The formulation was optimized by response surface methodology (RSM). The optimized microspheres were round. The entrapment efficiency was 57.49%. All the microspheres could float on the artificial gastric juice over 8 hours. The release of the drug from the microspheres complied with Fick's diffusion.

  19. Split-dose administration of a dual-action, low-volume bowel cleanser for colonoscopy: the SEE CLEAR I study.

    PubMed

    Rex, Douglas K; Katz, Philip O; Bertiger, Gerald; Vanner, Stephen; Hookey, Lawrence C; Alderfer, Vivian; Joseph, Raymond E

    2013-07-01

    New bowel cleansers for colonoscopy that lead to improved efficacy, safety, and tolerability are needed. This study evaluated a nonphosphate, dual-action, low-volume, orange-flavored preparation containing sodium picosulfate and magnesium citrate (P/MC). Multicenter, assessor-blinded, randomized, noninferiority study. University hospitals, academic medical centers, and private clinics across the United States. Adults preparing for colonoscopy. P/MC versus 2 L of polyethylene glycol solution (2L PEG-3350) and two 5-mg bisacodyl tablets. This phase 3 study investigated the efficacy, safety, and tolerability of split-dose administration of P/MC versus day-before dosing of 2L PEG-3350 and two 5-mg bisacodyl tablets (SEE CLEAR I study). Efficacy was evaluated by using the Aronchick and Ottawa scales; noninferiority and superiority analyses were performed. Safety was assessed by monitoring adverse events (AEs). Tolerability was measured via a patient questionnaire. The intent-to-treat population consisted of 601 patients who self-administered P/MC (n = 304) or 2L PEG-3350 and bisacodyl tablets (n = 297). P/MC was superior to 2L PEG-3350 and bisacodyl tablets in overall colon cleansing (84.2% vs 74.4%; 1-sided 97.5% confidence interval [CI], 3.4) (Aronchick scores of excellent or good) and in cleansing of the ascending (89.5% vs 78.8%; 1-sided 97.5% CI, 4.9), mid (transverse and descending) (92.4% vs 85.9%; 1-sided 97.5% CI, 1.6), and rectosigmoid (92.4% vs 87.2%; 1-sided 97.5% CI, 0.4) segments of the colon (Ottawa scores of excellent, good, or fair). Commonly reported AEs related to the bowel preparations were nausea, vomiting, headache, and chills. Patient-reported tolerability, including ease of consumption and taste, was significantly higher for P/MC than 2L PEG-3350 and bisacodyl tablets (P < .0001). Because of differences in administration and volume of the bowel preparations, the study was designed to be a single-assessor, blinded study. The bowel

  20. Strategies that target leukocyte traffic in inflammatory bowel diseases: recent developments.

    PubMed

    Rivera-Nieves, Jesús

    2015-11-01

    We review the most recent developments regarding the targeting of molecules involved in the traffic of leukocytes for the treatment of inflammatory bowel diseases (IBD). We discuss the most important findings of one published phase II trial that targeted the β7 integrin (etrolizumab), two phase II trials that targeted the α4β7 integrin ligand: mucosal addressin cell adhesion molecule 1 (MAdCAM-1, PF-00547659), a phase II trial targeting the chemokine IP-10 (CXCL10) in Crohn's, and a phase II trial that targeted the sphingosine-1-phosphate receptor-1: ozanimod in patients with ulcerative colitis. Targeting molecules involved in leukocyte traffic has recently become an effective and well tolerated strategy for the treatment of IBD. Novel approaches now not only target the integrins on the lymphocyte surface, but also its endothelial ligand: MAdCAM-1. As with vedolizumab, antibodies against MAdCAM-1 appear most effective in ulcerative colitis rather than in Crohn's. Targeting chemokines or their receptors does not appear to have the same efficacy as those that target the most stable integrin: immunoglobulin superfamily interactions between the lymphocyte and endothelium. Preliminary results also suggest that the sphingosine-1-phosphate pathway might also be targeted therapeutically in IBD, no longer with parenterally administered antibodies but with orally administered small molecules.

  1. Fecal calprotectin in inflammatory bowel disease

    PubMed Central

    Walsham, Natalie E; Sherwood, Roy A

    2016-01-01

    Inflammatory bowel disease (IBD) and irritable bowel syndrome share many symptoms. While irritable bowel syndrome is a functional bowel disorder for which no specific treatment is available, the range of effective therapies for IBD is evolving rapidly. Accurate diagnosis of IBD is therefore essential. Clinical assessment, together with various imaging modalities and endoscopy, has been the mainstay of diagnosis for many years. Fecal biomarkers of gastrointestinal inflammation have appeared in the past decade, of which calprotectin, a neutrophil cytosolic protein, has been studied the most. Crohn’s disease and ulcerative colitis are chronic remitting and relapsing diseases, and objective assessment of disease activity and response to treatment are important. This review focuses on the use of fecal calprotectin measurements in the diagnosis and monitoring of patients with IBD. PMID:26869808

  2. Lubiprostone improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled 2-way crossover study.

    PubMed

    Matsuura, Mizue; Inamori, Masahiko; Inou, Yumi; Kanoshima, Kenji; Higurashi, Takuma; Ohkubo, Hidenori; Iida, Hiroshi; Endo, Hiroki; Nonaka, Takashi; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi

    2017-06-01

     Lubiprostone has been reported to be an anti-constipation drug. The aim of the study was to investigate the usefulness of lubiprostone both for bowel preparation and as a propulsive agent in small bowel endoscopy.  This was a double-blind, placebo-controlled, 2-way crossover study of subjects who volunteered to undergo capsule endoscopy (CE). A total of 20 subjects (16 male and 4 female volunteers) were randomly assigned to receive a 24-μg tablet of lubiprostone 120 minutes prior to capsule ingestion for CE (L regimen), or a placebo tablet 120 minutes prior to capsule ingestion for CE (P regimen). Main outcome was gastric transit time (GTT) and small-bowel transit time (SBTT). Secondary outcome was adequacy of small-bowel cleansing and the fluid score in the small bowel. The quality of the capsule endoscopic images and fluid in the small bowel were assessed on 5-point scale.  The capsule passed into the small bowel in all cases. Median GTT was 57.3 (3 - 221) minutes for the P regimen and 61.3 (10 - 218) minutes for the L regimen ( P  = 0.836). Median SBTT was 245.0 (164 - 353) minutes for the P regimen and 228.05 (116 - 502) minutes for the L regimen ( P  = 0.501). The image quality score in the small bowel was 3.05 ± 1.08 for the P regimen and 3.80 ± 0.49 for the L regimen ( P  < 0.001). The fluid score in the small bowel was 2.04 ± 1.58 for the P regimen and 2.72 ± 1.43 for the L regimen ( P  < 0.001). There was a significant difference between the 2 regimens with regard to image quality. The fluid score was more plentiful for the L regimen than for the P regimen. There were no cases of capsule retention or serious adverse events in this study.  Our study showed that use of lubiprostone prior to CE significantly improved visualization of the small bowel during CE as a result of inducing fluid secretion into the small bowel.

  3. A prospective clinical study evaluating the development of bowel wall edema during laparoscopic and open visceral surgery.

    PubMed

    Marjanovic, Goran; Kuvendziska, Jasmina; Holzner, Philipp Anton; Glatz, Torben; Sick, Olivia; Seifert, Gabriel; Kulemann, Birte; Küsters, Simon; Fink, Jodok; Timme, Sylvia; Hopt, Ulrich Theodor; Wellner, Ulrich; Keck, Tobias; Karcz, Wojciech Konrad

    2014-12-01

    To examine bowel wall edema development in laparoscopic and open major visceral surgery. In a prospective study, 47 consecutively operated patients with gastric and pancreatic resections were included. Twenty-seven patients were operated in a conventional open procedure (open group) and 20 in a laparoscopic fashion (lap group). In all procedures, a small jejunal segment was resected during standard preparation, of which we measured the dry-wet ratio. Furthermore, HE staining was performed for measuring of bowel wall thickness and edema assessment. Mean value (±std) of dry-wet ratio was significantly lower in the open than in the lap group (0.169 ± 0.017 versus 0.179 ± 0.015; p = 0.03) with the same amount of fluid administration in both groups and a longer infusion interval during laparoscopic surgery. Subgroup analyses (only pancreatic resections) still showed similar results. Histologic examination depicted a significantly larger bowel wall thickness in the open group. Laparoscopic surgery does not seem to lead to the bowel wall edema observed to occur in open surgery regardless of the degree of intravenous fluid administration, thus supporting its use even in major visceral surgery.

  4. Muscarinic acetylcholine receptor expression in aganglionic bowel.

    PubMed

    Oue, T; Yoneda, A; Shima, H; Puri, P

    2000-01-01

    In Hirschsprung's disease (HD) there exists an overabundance of acetylcholine (ACh), which in turn stimulates excessive production of the enzyme acetylcholinesterase. Muscarinic ACh receptors (mAChRs) play an important role in smooth-muscle contraction. Recent studies have indicated five different subtypes of mAChRs encoded by five different genes, ml to m5. The purpose of this study was to investigate the expression of each mAChR subtype in aganglionic (AG) colon to further understand the pathophysiology of HD. Entire colon resected at the time of pull-through operation for HD was obtained from 14 patients. Specimens obtained at autopsy from 8 age-matched patients without gastrointestinal disease acted as controls. Frozen sections were used for indirect immunohistochemistry as well as in-situ hybridization. Immunohistochemistry was performed using specific antiserum against each mAChR subtype and in-situ hybridization was performed using specific oligonucleotide probes against ml to m5 subtypes. Messenger RNA (mRNA) was extracted from normoganglionic (NG) and AG bowel of HD patients and normal control bowel. Reverse transcription-polymerase chain reaction was performed to evaluate mRNA levels of each mAChR subtype. To adjust the levels of mRNA expression, a housekeeping gene G3PDH, known to be expressed normally, was used as an internal control. Strong m2 and m3 immunoreactivity was observed in the mucosal layer, smooth-muscle layers, and myenteric plexus of NG bowel, whereas ml immunoreactivity was only detected in the mucosal layer. The most striking finding was the abundance of m3-immunoreactive fibers in muscle layers of NG bowel while there was a total lack of m3 fibers in smooth-muscle of AG bowel. Intense mRNA signals encoding m2 and m3 and to a lesser degree ml were detected in NG bowel, and these signals were weak in AG bowel. Immunoreactivity and mRNA expression of m4 and m5 was not detected in NG or AG bowel. The lack of m3-immunoreactive fibers in the

  5. Chemical activation of gasification carbon residue for phosphate removal

    NASA Astrophysics Data System (ADS)

    Kilpimaa, Sari; Runtti, Hanna; Lassi, Ulla; Kuokkanen, Toivo

    2012-05-01

    Recycling of waste materials provides an economical and environmentally significant method to reduce the amount of waste. Bioash formed in the gasification process possesses a notable amount of unburned carbon and therefore it can be called a carbon residue. After chemical activation carbon residue could be use to replace activated carbon for example in wastewater purification processes. The effect of chemical activation process variables such as chemical agents and contact time in the chemical activation process were investigated. This study also explored the effectiveness of the chemically activated carbon residue for the removal of phosphate from an aqueous solution. The experimental adsorption study was performed in a batch reactor and the influence of adsorption time, initial phosphate concentration and pH was studied. Due to the carbon residue's low cost and high adsorption capacity, this type of waste has the potential to be utilised for the cost-effective removal of phosphate from wastewaters. Potential adsorbents could be prepared from these carbonaceous by-products and used as an adsorbent for phosphate removal.

  6. Maps showing selected geology and phosphate resources of the Snowdrift Mountain quadrangle, Bear Lake and Caribou Counties, Idaho

    USGS Publications Warehouse

    Derkey, Pamela Dunlap; Paul, Ken; Johnston, Bea; Palmer, Pamela; Zamanek, Alexander; Fakourbayat, Mahasti; Hovland, R.D.

    1985-01-01

    This report summarizes information on the thickness grade, lateral continuity, phosphate resources, and ownership of phosphate bearing units in the Meade Park Phosphatic Shale Member of the Phosphoria Formation in the Snowdrift Mountain quadrangle. This report is one of a series of quadrangle reports prepared by the Idaho Bureau of Mines and Geology under U.S. Geological Survey cost-sharing contract #14-08-0001-17925 to calculate phosphate resources in southeastern Idaho (fig.1).

  7. Frontiers in Drug Research and Development for Inflammatory Bowel Disease

    PubMed Central

    Currò, Diego; Pugliese, Daniela; Armuzzi, Alessandro

    2017-01-01

    Inflammatory bowel disease (IBD) is idiopathic, lifelong, immune-mediated diseases, for which curative therapies are not yet available. In the last 15 years, the introduction of monoclonal antibodies targeting tumor necrosis factor-α, a cytokine playing a key role in bowel inflammation, has revolutionized treatment paradigms for IBD. Despite their proven long-term efficacy, however, many patients do not respond or progressively lose response to these drugs. Major advances of knowledge in immunology and pathophysiology of intestinal inflammatory processes have made possible the identification of new molecular targets for drugs, thus opening several new potential therapeutic opportunities for IBD. The abnormal response of intestinal immunity to unknown antigens leads to the activation of T helper lymphocytes and triggers the inflammatory cascade. Sphingosine 1-phosphate receptor agonists negatively modulate the egress of lymphocytes, inducted by antigen-presenting cells, from secondary lymphoid tissues to intestinal wall. Leukocyte adhesion inhibitors (both anti-integrin and anti-Mucosal Vascular Addressin Cell Adhesion Molecule 1) interfere with the tissue homing processes. Activated T helper lymphocytes increase the levels of pro-inflammatory cytokines, such as interleukin 12, 23, and 6, offering several potential pharmacological interventions. The Janus kinases, intracellular enzymes mediating the transduction of several cytokine signals, are other explored targets for treating immune-mediated diseases. Finally, the impact of modulating Smad7 pathway, which is responsible for the down-regulation of the immunosuppressive cytokine transforming growth factor-β signaling, is currently under investigation. The purpose of this review is to discuss the most promising molecules in late-stage clinical development, with a special emphasis on pharmacological properties. PMID:28690543

  8. Lead iron phosphate glass as a containment medium for disposal of high-level nuclear waste

    DOEpatents

    Boatner, Lynn A.; Sales, Brian C.

    1989-01-01

    Lead-iron phosphate glasses containing a high level of Fe.sub.2 O.sub.3 for use as a storage medium for high-level radioactive nuclear waste. By combining lead-iron phosphate glass with various types of simulated high-level nuclear waste, a highly corrosion resistant, homogeneous, easily processed glass can be formed. For corroding solutions at 90.degree. C., with solution pH values in the range between 5 and 9, the corrosion rate of the lead-iron phosphate nuclear waste glass is at least 10.sup.2 to 10.sup.3 times lower than the corrosion rate of a comparable borosilicate nuclear waste glass. The presence of Fe.sub.2 O.sub.3 in forming the lead-iron phosphate glass is critical. Lead-iron phosphate nuclear waste glass can be prepared at temperatures as low as 800.degree. C., since they exhibit very low melt viscosities in the 800.degree. to 1050.degree. C. temperature range. These waste-loaded glasses do not readily devitrify at temperatures as high as 550.degree. C. and are not adversely affected by large doses of gamma radiation in H.sub.2 O at 135.degree. C. The lead-iron phosphate waste glasses can be prepared with minimal modification of the technology developed for processing borosilicate glass nuclear wasteforms.

  9. Role of capsule endoscopy in inflammatory bowel disease.

    PubMed

    Kopylov, Uri; Seidman, Ernest G

    2014-02-07

    Videocapsule endoscopy (VCE) has revolutionized our ability to visualize the small bowel mucosa. This modality is a valuable tool for the diagnosis of obscure small bowel Crohn's disease (CD), and can also be used for monitoring of disease activity in patients with established small-bowel CD, detection of complications such as obscure bleeding and neoplasms, evaluation of response to anti-inflammatory treatment and postoperative recurrence following small bowel resection. VCE could also be an important tool in the management of patients with unclassified inflammatory bowel disease, potentially resulting in reclassification of these patients as having CD. Reports on postoperative monitoring and evaluation of patients with ileal pouch-anal anastomosis who have developed pouchitis have recenty been published. Monitoring of colonic inflammatory activity in patients with ulcerative colitis using the recently developed colonic capsule has also been reported. Capsule endoscopy is associated with an excellent safety profile. Although retention risk is increased in patients with small bowel CD, this risk can be significanty decreased by a routine utilization of a dissolvable patency capsule preceding the ingestion of the diagnostic capsule. This paper contains an overview of the current and future clinical applications of capsule endoscopy in inflammatory bowel disease.

  10. Zirconium Phosphate Supported MOF Nanoplatelets.

    PubMed

    Kan, Yuwei; Clearfield, Abraham

    2016-06-06

    We report a rare example of the preparation of HKUST-1 metal-organic framework nanoplatelets through a step-by-step seeding procedure. Sodium ion exchanged zirconium phosphate, NaZrP, nanoplatelets were judiciously selected as support for layer-by-layer (LBL) assembly of Cu(II) and benzene-1,3,5-tricarboxylic acid (H3BTC) linkers. The first layer of Cu(II) is attached to the surface of zirconium phosphate through covalent interaction. The successive LBL growth of HKUST-1 film is then realized by soaking the NaZrP nanoplatelets in ethanolic solutions of cupric acetate and H3BTC, respectively. The amount of assembled HKUST-1 can be readily controlled by varying the number of growth cycles, which was characterized by powder X-ray diffraction and gas adsorption analyses. The successful construction of HKUST-1 on NaZrP was also supported by its catalytic performance for the oxidation of cyclohexene.

  11. Performance of fuel cell using calcium phosphate hydrogel membrane prepared from waste incineration fly ash and chicken bone powder.

    PubMed

    Fukui, Kunihiro; Arimitsu, Naoki; Jikihara, Kenji; Yamamoto, Tetsuya; Yoshida, Hideto

    2009-09-15

    Waste incineration fly ash and bone powder could be successfully recycled to calcium phosphate hydrogel, a type of fast proton conductor. The electric conductivity of the crystallized hydrogel from them was compared with that from calcium carbonate reagent. It was found that the conductivity of the hydrogel from bone powder is almost equal to that from calcium carbonate reagent, which is higher than that from incineration fly ash. Because the crystallized hydrogel from incineration ash has a lower crystallinity than that from bone powder and calcium carbonate reagent. However, the difference of the conductivity among them can be hardly observed above 100 degrees C. The fuel cell with membrane electrode assembly (MEA) using the calcium phosphate hydrogel membrane prepared from incineration fly ash and bone powder was observed to generate electricity. The performance of fuel cells having the hydrogel membrane obtained from all raw materials increases with the cell temperature, and the fuel cell containing the hydrogel membrane from incineration fly ash has the highest dependence of the fuel cell performance. For this reason, the difference in the cell performance among them can be hardly observed above 120 degrees C. This tendency agrees with the change in the electric conductivity with the temperature. Further, the performance of all fuel cells with the hydrogel membrane is superior to that of the fuel cell with perfluorosulfonic polymer membrane at temperatures greater than approximately 85 degrees C.

  12. Ability of a beta-casein phosphopeptide to modulate the precipitation of calcium phosphate by forming amorphous dicalcium phosphate nanoclusters.

    PubMed Central

    Holt, C; Wahlgren, N M; Drakenberg, T

    1996-01-01

    The ability of casein in the form of colloidal-sized casein micelles to modulate the phase separation of calcium phosphate during milk secretion is adapted to produce nanometre-sized particles of calcium phosphate stabilized by a casein phosphopeptide (nanoclusters). The nanoclusters were prepared from an undersaturated solution of salts and the peptide by raising the pH homogeneously from about 5.5 to 6.7 with urea plus urease. Chemical analysis and IR spectroscopy showed that they comprise an amorphous dicalcium phosophate bound to the phosphopeptide. Multinuclear NMR spectroscopy of the cluster solutions showed that the small ions and free peptide in the solution were in a state of dynamic exchange with the nanoclusters. The peptide is linked to the calcium phosphate through its sequence of phosphorylated residues, but, in a proportion of adsorbed conformational states, the termini retain the conformational freedom of the unbound peptide. The ability of casein to form nanoclusters in milk suggests a more general mechanism for avoiding pathological calcification and regulating calcium flow in tissues and biological fluids exposed to or containing high concentrations of calcium. PMID:8615755

  13. Large bowel and small bowel obstruction due to gallstones in the same patient

    PubMed Central

    Ranga, Natasha

    2011-01-01

    This is the case report of an 85-year-old woman who on two consecutive occasions presented with acute abdominal pain. The first presentation was large bowel obstruction. CT abdomen revealed this was due to a cholecystocolic fistula, allowing a large gallstone to pass and obstruct in the sigmoid colon. The second presentation was after laparotomy; the second CT abdomen revealed another gallstone causing small bowel obstruction. This case is interesting because cholelithiasis rarely leads to sigmoid colon obstruction (gallstone coleus)1 and gallstone ileus. Unfortunately, this patient had both. A gallstone causing obstruction in either the small or large bowel is rare, but occurrence of both in the same patient has not been reported to date. This case also shows how the elderly unwell surgical patient was mismanaged and she could have been spared surgery and irradiation if she was managed appropriately from the start. PMID:22696674

  14. Inflammatory Bowel Disease.

    PubMed

    2016-01-01

    Inflammation response plays an important role in host survival, and it also leads to acute and chronic inflammatory diseases such as rheumatoid arthritis, bowel diseases, allergic rhinitis, asthma, atopic dermatitis and various neurodegenerative diseases. During the course of inflammation, the ROS level increases. In addition to ROS, several inflammatory mediators produced at the site lead to numerous cell-mediated damages. Inflammatory bowel disease (IBD), including ulcerative colitis and Crohn's disease, is a chronic intestinal disorder resulting from a dysfunctional epithelial, innate and adaptive immune response to intestinal microorganisms. The methods involving indomethacin-induced enterocolitis in rats with macroscopic changes of IBD, myeloperoxidase assay, microscopic (histologic) characters and biochemical parameters are discussed.

  15. Method of waste stabilization with dewatered chemically bonded phosphate ceramics

    DOEpatents

    Wagh, Arun; Maloney, Martin D.

    2010-06-29

    A method of stabilizing a waste in a chemically bonded phosphate ceramic (CBPC). The method consists of preparing a slurry including the waste, water, an oxide binder, and a phosphate binder. The slurry is then allowed to cure to a solid, hydrated CBPC matrix. Next, bound water within the solid, hydrated CBPC matrix is removed. Typically, the bound water is removed by applying heat to the cured CBPC matrix. Preferably, the quantity of heat applied to the cured CBPC matrix is sufficient to drive off water bound within the hydrated CBPC matrix, but not to volatalize other non-water components of the matrix, such as metals and radioactive components. Typically, a temperature range of between 100.degree. C.-200.degree. C. will be sufficient. In another embodiment of the invention wherein the waste and water have been mixed prior to the preparation of the slurry, a select amount of water may be evaporated from the waste and water mixture prior to preparation of the slurry. Another aspect of the invention is a direct anyhydrous CBPC fabrication method wherein water is removed from the slurry by heating and mixing the slurry while allowing the slurry to cure. Additional aspects of the invention are ceramic matrix waste forms prepared by the methods disclosed above.

  16. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope.

    PubMed

    Ching, Siok Siong; Tan, Yih Kai

    2012-09-07

    To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann(®) Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen

  17. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope

    PubMed Central

    Ching, Siok Siong; Tan, Yih Kai

    2012-01-01

    AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann® Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. RESULTS: A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant

  18. Usefulness of bowel sound auscultation: a prospective evaluation.

    PubMed

    Felder, Seth; Margel, David; Murrell, Zuri; Fleshner, Phillip

    2014-01-01

    Although the auscultation of bowel sounds is considered an essential component of an adequate physical examination, its clinical value remains largely unstudied and subjective. The aim of this study was to determine whether an accurate diagnosis of normal controls, mechanical small bowel obstruction (SBO), or postoperative ileus (POI) is possible based on bowel sound characteristics. Prospectively collected recordings of bowel sounds from patients with normal gastrointestinal motility, SBO diagnosed by computed tomography and confirmed at surgery, and POI diagnosed by clinical symptoms and a computed tomography without a transition point. Study clinicians were instructed to categorize the patient recording as normal, obstructed, ileus, or not sure. Using an electronic stethoscope, bowel sounds of healthy volunteers (n = 177), patients with SBO (n = 19), and patients with POI (n = 15) were recorded. A total of 10 recordings randomly selected from each category were replayed through speakers, with 15 of the recordings duplicated to surgical and internal medicine clinicians (n = 41) blinded to the clinical scenario. The sensitivity, positive predictive value, and intra-rater variability were determined based on the clinician's ability to properly categorize the bowel sound recording when blinded to additional clinical information. Secondary outcomes were the clinician's perceived level of expertise in interpreting bowel sounds. The overall sensitivity for normal, SBO, and POI recordings was 32%, 22%, and 22%, respectively. The positive predictive value of normal, SBO, and POI recordings was 23%, 28%, and 44%, respectively. Intra-rater reliability of duplicated recordings was 59%, 52%, and 53% for normal, SBO, and POI, respectively. No statistically significant differences were found between the surgical and internal medicine clinicians for sensitivity, positive predictive value, or intra-rater variability. Overall, 44% of clinicians reported that they rarely listened

  19. Iron phosphate compositions for containment of hazardous metal waste

    DOEpatents

    Day, Delbert E.

    1998-01-01

    An improved iron phosphate waste form for the vitrification, containment and long-term disposition of hazardous metal waste such as radioactive nuclear waste is provided. The waste form comprises a rigid iron phosphate matrix resulting from the cooling of a melt formed by heating a batch mixture comprising the metal waste and a matrix-forming component. The waste form comprises from about 30 to about 70 weight percent P.sub.2 O.sub.5 and from about 25 to about 50 weight percent iron oxide and has metals present in the metal waste chemically dissolved therein. The concentration of iron oxide in the waste form along with a high proportion of the iron in the waste form being present as Fe.sup.3+ provide a waste form exhibiting improved chemical resistance to corrosive attack. A method for preparing the improved iron phosphate waste forms is also provided.

  20. Iron phosphate compositions for containment of hazardous metal waste

    DOEpatents

    Day, D.E.

    1998-05-12

    An improved iron phosphate waste form for the vitrification, containment and long-term disposition of hazardous metal waste such as radioactive nuclear waste is provided. The waste form comprises a rigid iron phosphate matrix resulting from the cooling of a melt formed by heating a batch mixture comprising the metal waste and a matrix-forming component. The waste form comprises from about 30 to about 70 weight percent P{sub 2}O{sub 5} and from about 25 to about 50 weight percent iron oxide and has metals present in the metal waste chemically dissolved therein. The concentration of iron oxide in the waste form along with a high proportion of the iron in the waste form being present as Fe{sup 3+} provide a waste form exhibiting improved chemical resistance to corrosive attack. A method for preparing the improved iron phosphate waste forms is also provided. 21 figs.

  1. Phosphate Solubilization and Gene Expression of Phosphate-Solubilizing Bacterium Burkholderia multivorans WS-FJ9 under Different Levels of Soluble Phosphate.

    PubMed

    Zeng, Qingwei; Wu, Xiaoqin; Wang, Jiangchuan; Ding, Xiaolei

    2017-04-28

    Phosphate-solubilizing bacteria (PSB) have the ability to dissolve insoluble phosphate and enhance soil fertility. However, the growth and mineral phosphate solubilization of PSB could be affected by exogenous soluble phosphate and the mechanism has not been fully understood. In the present study, the growth and mineral phosphate-solubilizing characteristics of PSB strain Burkholderia multivorans WS-FJ9 were investigated at six levels of exogenous soluble phosphate (0, 0.5, 1, 5, 10, and 20 mM). The WS-FJ9 strain showed better growth at high levels of soluble phosphate. The phosphate-solubilizing activity of WS-FJ9 was reduced as the soluble phosphate concentration increased, as well as the production of pyruvic acid. Transcriptome profiling of WS-FJ9 at three levels of exogenous soluble phosphate (0, 5, and 20 mM) identified 446 differentially expressed genes, among which 44 genes were continuously up-regulated when soluble phosphate concentration was increased and 81 genes were continuously down-regulated. Some genes related to cell growth were continuously up-regulated, which would account for the better growth of WS-FJ9 at high levels of soluble phosphate. Genes involved in glucose metabolism, including glycerate kinase, 2-oxoglutarate dehydrogenase, and sugar ABC-type transporter, were continuously down-regulated, which indicates that metabolic channeling of glucose towards the phosphorylative pathway was negatively regulated by soluble phosphate. These findings represent an important first step in understanding the molecular mechanisms of soluble phosphate effects on the growth and mineral phosphate solubilization of PSB.

  2. Differentiating phosphate-dependent and phosphate-independent systemic phosphate-starvation response networks in Arabidopsis thaliana through the application of phosphite

    PubMed Central

    Jost, Ricarda; Pharmawati, Made; Lapis-Gaza, Hazel R.; Rossig, Claudia; Berkowitz, Oliver; Lambers, Hans; Finnegan, Patrick M.

    2015-01-01

    Phosphite is a less oxidized form of phosphorus than phosphate. Phosphite is considered to be taken up by the plant through phosphate transporters. It can mimic phosphate to some extent, but it is not metabolized into organophosphates. Phosphite could therefore interfere with phosphorus signalling networks. Typical physiological and transcriptional responses to low phosphate availability were investigated and the short-term kinetics of their reversion by phosphite, compared with phosphate, were determined in both roots and shoots of Arabidopsis thaliana. Phosphite treatment resulted in a strong growth arrest. It mimicked phosphate in causing a reduction in leaf anthocyanins and in the expression of a subset of the phosphate-starvation-responsive genes. However, the kinetics of the response were slower than for phosphate, which may be due to discrimination against phosphite by phosphate transporters PHT1;8 and PHT1;9 causing delayed shoot accumulation of phosphite. Transcripts encoding PHT1;7, lipid-remodelling enzymes such as SQD2, and phosphocholine-producing NMT3 were highly responsive to phosphite, suggesting their regulation by a direct phosphate-sensing network. Genes encoding components associated with the ‘PHO regulon’ in plants, such as At4, IPS1, and PHO1;H1, generally responded more slowly to phosphite than to phosphate, except for SPX1 in roots and MIR399d in shoots. Two uncharacterized phosphate-responsive E3 ligase genes, PUB35 and C3HC4, were also highly phosphite responsive. These results show that phosphite is a valuable tool to identify network components directly responsive to phosphate. PMID:25697796

  3. Chronic bowel inflammation and inflammatory joint disease: Pathophysiology.

    PubMed

    Speca, Silvia; Dubuquoy, Laurent

    2017-07-01

    Bowel inflammation is closely linked to chronic joint inflammation. Research reported in the 1980s demonstrated bowel inflammation with gross and microscopic pathological features identical to those of Crohn's disease in over 60% of patients with spondyloarthritis (SpA). Numerous prospective studies have evidenced joint involvement in patients with chronic inflammatory bowel disease (IBD) and bowel inflammation in patients with SpA. Nevertheless, the interactions of joint disease and chronic bowel inflammation remain incompletely elucidated. Two main hypotheses have been suggested to explain potential links between inflammation of the mucosal immune system and peripheral arthritis: one identifies gut bacteria as potentially implicated in the development of joint inflammation and the other involves the recruitment of gut lymphocytes or activated macrophages to the joints. Pathophysiological investigations have established that HLA-B27 is a pivotal pathogenic factor. Here, we review current data on links between chronic bowel inflammation and inflammatory joint disease. Copyright © 2017 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  4. First clinical trial of a newly developed capsule endoscope with panoramic side view for small bowel: a pilot study.

    PubMed

    Friedrich, Kilian; Gehrke, Sven; Stremmel, Wolfgang; Sieg, Andreas

    2013-09-01

    Capsule endoscopy is the first-line diagnostic technique for the small bowel. However, the inability to visualize the duodenal papilla is an inherent limitation of this method. In the present study, we evaluated feasibility of a newly developed CapsoCam SV1 capsule. This is a prospective dual center study of a newly developed video capsule CapsoCam SV1 from Capsovision, CA, providing panoramic 360° imaging. A high frequency of 20 frames occurs per second for the first 2 h and thereafter 12 frames/s, with a battery life of 15 h. We evaluated feasibility and completeness of small bowel examination together with secondary endpoints of duodenal papilla detection in 33 patients. Patients swallowed the capsules following colonoscopy or were prepared with 2 L of polyethylene glycol solution prior to the examination. All patients swallowed 20 mg of metoclopramide and 160 mg of simethicone 30 min before ingestion of the capsule. Thirty-one of the 33 patients' data could be evaluated. Small bowel examination was complete in all procedures. Mean time to pass the small bowel was 258 ± 136 min. Average small bowel cleanliness was 3.3 ± 0.5. In 71% of the patients, we identified the duodenal papilla. No adverse reaction in relation to the capsule examination was observed. CapsoCam SV1 is a safe and efficient tool in small bowel examination. The duodenal papilla as the only landmark in small bowel is detected in more than 70% of the patients. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  5. Bowel-associated dermatosis - arthritis syndrome in a patient with ulcerative colitis: an extraintestinal manifestation of inflammatory bowel disease.

    PubMed

    DeFilippis, Ersilia M; Magro, Cynthia; Jorizzo, Joseph L

    2014-10-01

    Bowel-associated dermatosis - arthritis syndrome (BADAS) is a neutrophilic dermatosis characterized by cutaneous lesions that begin as erythematous macules and progress to vesiculopustular eruptions. It has been described in patients with inflammatory bowel disease as well as those who have undergone various intestinal surgeries. Pathologically, the lesions show features of vasculitis without fibrinoid necrosis. In a patient with diagnosed inflammatory bowel disease, these neutrophilic dermatoses should be viewed as external signals of bowel inflammation. Management requires long-term treatment of the underlying disease. We report a case of BADAS in a patient with ulcerative colitis in which the skin lesions were associated with increased colonic inflammation.

  6. Synthetic process for preparation of high surface area electroactive compounds for battery applications

    DOEpatents

    Evenson, Carl; Mackay, Richard

    2013-07-23

    A process is disclosed for the preparation of electroactive cathode compounds useful in lithium-ion batteries, comprising exothermic mixing of low-cost precursors and calcination under appropriate conditions. The exothermic step may be a spontaneous flameless combustion reaction. The disclosed process can be used to prepare any lithium metal phosphate or lithium mixed metal phosphate as a high surface area single phase compound.

  7. MRI diffusion-weighted imaging (DWI) in pediatric small bowel Crohn disease: correlation with MRI findings of active bowel wall inflammation.

    PubMed

    Ream, Justin M; Dillman, Jonathan R; Adler, Jeremy; Khalatbari, Shokoufeh; McHugh, Jonathan B; Strouse, Peter J; Dhanani, Muhammad; Shpeen, Benjamin; Al-Hawary, Mahmoud M

    2013-09-01

    Restricted diffusion on diffusion-weighted imaging (DWI) sequences during magnetic resonance enterography (MRE) has been shown in segments of bowel affected by Crohn disease. However, the exact meaning of this finding, particularly within the pediatric Crohn disease population, is poorly understood. The purpose of this study was to determine the significance of bowel wall restricted diffusion in children with small bowel Crohn disease by correlating apparent diffusion coefficient (ADC) values with other MRI markers of disease activity. A retrospective review of pediatric patients (≤ 18 years of age) with Crohn disease terminal ileitis who underwent MRE with DWI at our institution between May 1, 2009 and May 31, 2011 was undertaken. All of the children had either biopsy-proven Crohn disease terminal ileitis or clinically diagnosed Crohn disease, including terminal ileal involvement by imaging. The mean minimum ADC value within the wall of the terminal ileum was determined for each examination. ADC values were tested for correlation/association with other MRI findings to determine whether a relationship exists between bowel wall restricted diffusion and disease activity. Forty-six MRE examinations with DWI in children with terminal ileitis were identified (23 girls and 23 boys; mean age, 14.3 years). There was significant negative correlation or association between bowel wall minimum ADC value and established MRI markers of disease activity, including degree of bowel wall thickening (R = (-)0.43; P = 0.003), striated pattern of arterial enhancement (P = 0.01), degree of arterial enhancement (P = 0.01), degree of delayed enhancement (P = 0.045), amount of mesenteric inflammatory changes (P < 0.0001) and presence of a stricture (P = 0.02). ADC values were not significantly associated with bowel wall T2-weighted signal intensity, length of disease involvement or mesenteric fibrofatty proliferation. Increasing bowel wall restricted diffusion

  8. Aminopropyl-functionalized mesoporous carbon (APTMS-CMK-3) as effective phosphate adsorbent

    NASA Astrophysics Data System (ADS)

    Yang, Yanju; Wang, Juanjuan; Qian, Xiaoqing; Shan, Yuhua; Zhang, Haipeng

    2018-01-01

    Excess phosphate discharge into water bodies can lead to severe eutrophication. Adsorption has been considered as one of the most effective approaches for phosphate removal and recovery. A new aminopropyl-functionalized mesoporous carbon CMK-3 (denoted as APTMS-CMK-3) was prepared and the materials were used as adsorbents for the removal of phosphate in water. The structure, functional groups and surface charge of the materials were characterized by X-ray powder diffraction, transmission electron microscope, N2 adsorption-desorption, elemental analysis, Fourier transform infrared spectra, X-ray photoelectron spectroscopy and zeta potential measurements. The effects of contact time, initial phosphate concentration, solution pH, coexisting anions and dissolved humic acid were studied. The adsorption capacity of APTMS-CMK-3 was 38.09 mg g-1 at the equilibrium concentration of 49.06 mg L-1, and the adsorption data were well fitted with the Freundlich model. As for the reuse of APTMS-CMK-3, a relatively stable adsorption performance was observed after five adsorption-desorption cycles. Therefore, the way of grafting aminopropyl groups on the CMK-3 efficiently enhanced the capability for phosphate adsorption, indicating that it could be used as potential adsorbents for the removal of phosphate in water.

  9. Half doses of PEG-ES and senna vs. high-dose senna for bowel cleansing before colonoscopy: a randomized, investigator-blinded trial.

    PubMed

    Amato, Arnaldo; Radaelli, Franco; Paggi, Silvia; Terruzzi, Vittorio

    2010-03-01

    Patients' compliance with and tolerance of large-volume polyethylene glycol electrolyte solution (PEG-ES) have prompted continuous investigation with alternative forms of cleansing. High-dose senna is superior to PEG-ES for the quality of bowel cleansing, patient compliance, and tolerance, but its acceptance may be influenced by the incidence of abdominal pain. We hypothesized that a combination of half doses of PEG-ES and senna could minimize the incidence of abdominal pain without affecting the quality of bowel preparation. This randomized, investigator-blinded trial has been conducted on consecutive outpatients scheduled for elective colonoscopy at a single community-based hospital. Patients were randomly assigned to receive either 12 tablets of 12 mg senna and 2 l of PEG-ES (half-dose group, HDG) or 24 tablets of senna divided in two doses (senna group, SG) the day before colonoscopy. The main outcome measures were the quality of colon cleansing (Aronchick scoring scale) and the incidence of preparation-related abdominal pain. Secondary outcome measures were patients' compliance with the cleansing regimen, overall tolerability, prevalence of predefined side effects, and quality of right colon cleansing. A total of 296 patients were enrolled (HDG=151 and SG=145). Overall cleansing was excellent to good in 90.1 and 88.3% patients in HDG and SG, respectively (P=0.62). Preparation-related moderate-to-severe abdominal pain was reported by 6% patients in HDG and 15.2% in SG (P=0.009). No significant differences were observed for secondary outcomes. The regimen combining half doses of PEG-ES and senna provides high-quality bowel preparation and acceptable patient tolerance, with less abdominal pain compared with high-dose senna.

  10. A simple and effective approach to prepare injectable macroporous calcium phosphate cement for bone repair: Syringe-foaming using a viscous hydrophilic polymeric solution.

    PubMed

    Zhang, Jingtao; Liu, Weizhen; Gauthier, Olivier; Sourice, Sophie; Pilet, Paul; Rethore, Gildas; Khairoun, Khalid; Bouler, Jean-Michel; Tancret, Franck; Weiss, Pierre

    2016-02-01

    In this study, we propose a simple and effective strategy to prepare injectable macroporous calcium phosphate cements (CPCs) by syringe-foaming via hydrophilic viscous polymeric solution, such as using silanized-hydroxypropyl methylcellulose (Si-HPMC) as a foaming agent. The Si-HPMC foamed CPCs demonstrate excellent handling properties such as injectability and cohesion. After hardening the foamed CPCs possess hierarchical macropores and their mechanical properties (Young's modulus and compressive strength) are comparable to those of cancellous bone. Moreover, a preliminary in vivo study in the distal femoral sites of rabbits was conducted to evaluate the biofunctionality of this injectable macroporous CPC. The evidence of newly formed bone in the central zone of implantation site indicates the feasibility and effectiveness of this foaming strategy that will have to be optimized by further extensive animal experiments. A major challenge in the design of biomaterial-based injectable bone substitutes is the development of cohesive, macroporous and self-setting calcium phosphate cement (CPC) that enables rapid cell invasion with adequate initial mechanical properties without the use of complex processing and additives. Thus, we propose a simple and effective strategy to prepare injectable macroporous CPCs through syringe-foaming using a hydrophilic viscous polymeric solution (silanized-hydroxypropyl methylcellulose, Si-HPMC) as a foaming agent, that simultaneously meets all the aforementioned aims. Evidence from our in vivo studies shows the existence of newly formed bone within the implantation site, indicating the feasibility and effectiveness of this foaming strategy, which could be used in various CPC systems using other hydrophilic viscous polymeric solutions. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Same-day 2-L PEG-citrate-simethicone plus bisacodyl vs split 4-L PEG: Bowel cleansing for late-morning colonoscopy.

    PubMed

    de Leone, Annalisa; Tamayo, Darina; Fiori, Giancarla; Ravizza, Davide; Trovato, Cristina; De Roberto, Giuseppe; Fazzini, Linda; Dal Fante, Marco; Crosta, Cristiano

    2013-09-16

    To evaluate the efficacy, tolerability, acceptability and feasibility of bisacodyl plus low volume polyethyleneglycol-citrate-simeticone (2-L PEG-CS) taken the same day as compared with conventional split-dose 4-L PEG for late morning colonoscopy. Randomised, observer-blind, parallel group, comparative trial carried out in 2 centres. Out patients of both sexes, aged between 18 and 85 years, undergoing colonoscopy for diagnostic investigation, colorectal cancer screening or follow-up were eligible. The PEG-CS group received 3 bisacodyl tablets (4 tablets for patients with constipation) at bedtime and 2-L PEG-CS in the morning starting 5 h before colonoscopy. The control group received a conventional 4-L PEG formulation given as split regimen; the morning dose was taken with the same schedule of the low volume preparation. The Ottawa Bowel Preparation Scale (OBPS) score was used as the main outcome measure. A total of 164 subjects were enrolled and 154 completed the study; 78 in the PEG-CS group and 76 in the split 4-L PEG group. The two groups were comparable at baseline. The OBPS score in the PEG-CS group (3.09 ± 2.40) and in the PEG group (2.39 ± 2.55) were equivalent (difference +0.70; 95%CI: -0.09-1.48). This was confirmed by the rate of successful bowel cleansing in the PEG-CS group (89.7%) and in the PEG group (92.1%) (difference -2.4%; 95%CI: -11.40- 6.70). PEG-CS was superior in terms of mucosa visibility compared to PEG (85.7% vs 72.4%, P = 0.042). There were no significant differences in caecum intubation rate, time to reach the caecum and withdrawal time between the two groups. The adenoma detection rate was similar (PEG-CS 43.6% vs PEG 44.7%). No serious adverse events occurred. No difference was found in tolerability of the bowel preparations. Compliance was equal in both groups: more than 90% of subjects drunk the whole solution. Willingness to repeat the same bowel preparations was about 90% for both regimes. Same-day PEG-CS is feasible, effective

  12. PSYCHOLOGICAL ASPECTS OF IRRITABLE BOWEL SYNDROME

    PubMed Central

    Rajagopalan, Mani; Kurian, George; John, Jacob K.

    1996-01-01

    Psychological aspects of Irritable Bowel Syndrome have been well investigated in Western countries, but there is a paucity of Indian studies focusing on this area. A series of fifty patients with the Irritable Bowel Syndrome were studied with respect to their depressive symptoms, anxiety symptoms and their personality traits. Patients had a mean score of 14.68 on Hamilton's depression rating scale and 11.22 on Hamilton's anxiety rating scale, and were more introverted and more neurotic than the general population. No association was found between psychological symptoms and severity of gastrointestinal symptoms. These findings suggest that psychological symptoms are a concomitant part of the Irritable Bowel Syndrome. PMID:21584134

  13. Fecal hydroxysteroid dehydrogenase activities in vegetarian Seventh-Day Adventists, control subjects, and bowel cancer patients.

    PubMed

    Macdonald, I A; Webb, G R; Mahony, D E

    1978-10-01

    Cell-free extracts were prepared from mixed fecal anaerobic bacteria grown from stools of 14 vegetarian Seventh-Day Adventists, 16 omnivorous control subjects, and eight patients recently diagnosed with cancer of the large bowel. Preparations were assayed for NAD- and NADP-dependent 3alpha-, 7alpha- and 12alpha-hydroxysteroid dehydrogenases with bile salts and androsterone as substrates (eight substrate-cofactor combinations were tested). A significant intergroup difference was observed in the amounts of NAD- and NADP-dependent 7alpha-hydroxysteroid dehydrogenase produced: bowel cancer patients exceeded controls, and controls exceeded Seventh-Day Adventists. Other enzyme activity comparisons were not significant. The pH values of the stools were significantly higher in cancer patients compared to Seventh-Day Adventists; values were 7.03 +/- 0.60 and 6.46 +/- 0.58 respectively. The pH value for controls was 6.66 +/- 0.62. A plot of pH value versus NADP-dependent 7alpha-hydroxysteroid dehydrogenase tended to separate the cancer patients from the other groups. Comparative data suggest that much of the 3alpha-hydroxysteroid dehydrogenase active against bile salt is also active against androsterone.

  14. Mechanical properties of calcium phosphate scaffolds fabricated by robocasting.

    PubMed

    Miranda, Pedro; Pajares, Antonia; Saiz, Eduardo; Tomsia, Antoni P; Guiberteau, Fernando

    2008-04-01

    The mechanical behavior under compressive stresses of beta-tricalcium phosphate (beta-TCP) and hydroxyapatite (HA) scaffolds fabricated by direct-write assembly (robocasting) technique is analyzed. Concentrated colloidal inks prepared from beta-TCP and HA commercial powders were used to fabricate porous structures consisting of a 3-D tetragonal mesh of interpenetrating ceramic rods. The compressive strength and elastic modulus of these model scaffolds were determined by uniaxial testing to compare the relative performance of the selected materials. The effect of a 3-week immersion in simulated body fluid (SBF) on the strength of the scaffolds was also analyzed. The results are compared with those reported in the literature for calcium phosphate scaffolds and human bone. The robocast calcium phosphate scaffolds were found to exhibit excellent mechanical performances in terms of strength, especially the HA structures after SBF immersion, indicating a great potential of this type of scaffolds for use in load-bearing bone tissue engineering applications. Copyright 2007 Wiley Periodicals, Inc.

  15. Efficacy of bowel cancer appeals for promoting physical activity.

    PubMed

    Jalleh, Geoffrey; Donovan, Robert J; Slevin, Terry; Dixon, Helen

    2005-08-01

    To investigate the potential efficacy of bowel cancer prevention messages in increasing intentions to be more physically active. A convenience sample of 281 physically inactive persons aged 30-60 years was recruited in the Perth city centre and randomly assigned to a bowel cancer and physical activity message or a heart disease and physical activity message. After reading a booklet containing information about physical activity and its link either to bowel cancer (n = 141) or cardiovascular disease (n = 140), respondents filled in a self-completion questionnaire. The main response measures were impact on intentions to be more physically active, and perceived believability and relevance of the message. Perceived believability of the message was high in both conditions. Perceived personal relevance of the message was substantially lower in the bowel cancer than the cardiovascular disease condition. Overall, the cardiovascular disease condition achieved somewhat higher behavioural intentions than the bowel cancer condition. The finding that two in three respondents in the bowel cancer condition had increased intention to increase their level of physical activity provides support for the potential efficacy of promoting physical activity in reducing the risk of bowel cancer.

  16. Bioavailable dietary phosphate, a mediator of cardiovascular disease, may be decreased with plant-based diets, phosphate binders, niacin, and avoidance of phosphate additives.

    PubMed

    McCarty, Mark F; DiNicolantonio, James J

    2014-01-01

    Increased fasting serum phosphate within the normal physiological range has been linked to increased cardiovascular risk in prospective epidemiology; increased production of fibroblast growth factor 23, and direct vascular effects of phosphate, may mediate this risk. Although dietary phosphate intake does not clearly influence fasting serum phosphate in individuals with normal renal function, increased phosphate intake can provoke a rise in fibroblast growth factor 23, and in diurnal phosphate levels, and hence may adversely influence vascular health. Dietary phosphate absorption can be moderated by emphasizing plant-based dietary choices (which provide phosphate in less bioavailable forms); avoidance of processed foods containing inorganic phosphate food additives; and by ingestion of phosphate-binder drugs, magnesium supplements, or niacin, which precipitate phosphate or suppress its gastrointestinal absorption. The propensity of dietary phosphate to promote vascular calcification may be opposed by optimal intakes of magnesium, vitamin K, and vitamin D; the latter should also counter the tendency of phosphate to elevate parathyroid hormone. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Selective laser sintering of calcium phosphate materials for orthopedic implants

    NASA Astrophysics Data System (ADS)

    Lee, Goonhee

    Two technologies, Solid Freeform Fabrication (SFF) and bioceramics are combined in this work to prepare bone replacement implants with complex geometry. SFF has emerged as a crucial technique for rapid prototyping in the last decade. Selective Laser Sintering (SLS) is one of the established SFF manufacturing processes that can build three-dimensional objects directly from computer models without part-specific tooling or human intervention. Meanwhile, there have been great efforts to develop implantable materials that can assist in regeneration of bone defects and injuries. However, little attention has been focused in shaping bones from these materials. The main thrust of this research was to develop a process that can combine those two separate efforts. The specific objective of this research is to develop a process that can construct bone replacement material of complex geometry from synthetic calcium phosphate materials by using the SLS process. The achievement of this goal can have a significant impact on the quality of health care in the sense that complete custom-fit bone and tooth structures suitable for implantation can be prepared within 24--48 hours of receipt of geometric information obtained either from patient Computed Tomographic (CT) data, from Computer Aided Design (CAD) software or from other imaging systems such as Magnetic Resonance Imaging (MRI) and Holographic Laser Range Imaging (HLRI). In this research, two different processes have been developed. First is the SLS fabrication of porous bone implants. In this effort, systematic procedures have been established and calcium phosphate implants were successfully fabricated from various sources of geometric information. These efforts include material selection and preparation, SLS process parameter optimization, and development of post-processing techniques within the 48-hour time frame. Post-processing allows accurate control of geometry and of the chemistry of calcium phosphate, as well as

  18. [Short bowel syndrome].

    PubMed

    Parfenov, A I; Sabelnikova, E A; Kuzmina, T N

    2017-01-01

    The paper gives information on the classification, pathogenesis, and clinical manifestations of short bowel syndrome following after intestinal resection. It discusses the treatment and rehabilitation of patients with this condition.

  19. Recording and Analysis of Bowel Sounds.

    PubMed

    Zaborski, Daniel; Halczak, Miroslaw; Grzesiak, Wilhelm; Modrzejewski, Andrzej

    2015-01-01

    The aim of this study was to construct an electronic bowel sound recording system and determine its usefulness for the diagnosis of appendicitis, mechanical ileus and diffuse peritonitis. A group of 67 subjects aged 17 to 88 years including 15 controls was examined. Bowel sounds were recorded using an electret microphone placed on the right side of the hypogastrium and connected to a laptop computer. The method of adjustable grids (converted into binary matrices) was used for bowel sounds analysis. Significantly, fewer (p ≤ 0.05) sounds were found in the mechanical ileus (1004.4) and diffuse peritonitis (466.3) groups than in the controls (2179.3). After superimposing adjustable binary matrices on combined sounds (interval between sounds <0.01 s), significant relationships (p ≤ 0.05) were found between particular positions in the matrices (row-column) and the patient groups. These included the A1_T1 and A1_T2 positions and mechanical ileus as well as the A1_T2 and A1_T4 positions and appendicitis. For diffuse peritonitis, significant positions were A5_T4 and A1_T4. Differences were noted in the number of sounds and binary matrices in the groups of patients with acute abdominal diseases. Certain features of bowel sounds characteristic of individual abdominal diseases were indicated. BS: bowel sound; APP: appendicitis; IL: mechanical ileus; PE: diffuse peritonitis; CG: control group; NSI: number of sound impulses; NCI: number of combined sound impulses; MBS: mean bit-similarity; TMIN: minimum time between impulses; TMAX: maximum time between impulses; TMEAN: mean time between impulses. Zaborski D, Halczak M, Grzesiak W, Modrzejewski A. Recording and Analysis of Bowel Sounds. Euroasian J Hepato-Gastroenterol 2015;5(2):67-73.

  20. Factors Associated with Anxiety About Colonoscopy: The Preparation, the Procedure, and the Anticipated Findings.

    PubMed

    Shafer, L A; Walker, J R; Waldman, C; Yang, C; Michaud, V; Bernstein, C N; Hathout, L; Park, J; Sisler, J; Restall, G; Wittmeier, K; Singh, H

    2018-03-01

    Previous research has assessed anxiety around colonoscopy procedures, but has not considered anxiety related to different aspects related to the colonoscopy process. Before colonoscopy, we assessed anxiety about: bowel preparation, the procedure, and the anticipated results. We evaluated associations between patient characteristics and anxiety in each area. An anonymous survey was distributed to patients immediately prior to their outpatient colonoscopy in six hospitals and two ambulatory care centers in Winnipeg, Canada. Anxiety was assessed using a visual analog scale. For each aspect, logistic regression models were used to explore associations between patient characteristics and high anxiety. A total of 1316 respondents completed the questions about anxiety (52% female, median age 56 years). Anxiety scores > 70 (high anxiety) were reported by 18% about bowel preparation, 29% about the procedure, and 28% about the procedure results. High anxiety about bowel preparation was associated with female sex, perceived unclear instructions, unfinished laxative, and no previous colonoscopies. High anxiety about the procedure was associated with female sex, no previous colonoscopies, and confusing instructions. High anxiety about the results was associated with symptoms as an indication for colonoscopy and instructions perceived as confusing. Fewer people had high anxiety about preparation than about the procedure and findings of the procedure. There are unique predictors of anxiety about each colonoscopy aspect. Understanding the nuanced differences in aspects of anxiety may help to design strategies to reduce anxiety, leading to improved acceptance of the procedure, compliance with preparation instructions, and less discomfort with the procedure.

  1. Mechanical Extension Implants for Short-Bowel Syndrome.

    PubMed

    Luntz, Jonathan; Brei, Diann; Teitelbaum, Daniel; Spencer, Ariel

    2006-01-01

    Short-bowel syndrome (SBS) is a rare, potentially lethal medical condition where the small intestine is far shorter than required for proper nutrient absorption. Current treatment, including nutritional, hormone-based, and surgical modification, have limited success resulting in 30% to 50% mortality rates. Recent advances in mechanotransduction, stressing the bowel to induce growth, show great promise; but for successful clinical use, more sophisticated devices that can be implanted are required. This paper presents two novel devices that are capable of the long-term gentle stressing. A prototype of each device was designed to fit inside a short section of bowel and slowly extend, allowing the bowel section to grow approximately double its initial length. The first device achieves this through a dual concentric hydraulic piston that generated almost 2-fold growth of a pig small intestine. For a fully implantable extender, a second device was developed based upon a shape memory alloy actuated linear ratchet. The proof-of-concept prototype demonstrated significant force generation and almost double extension when tested on the benchtop and inside an ex-vivo section of pig bowel. This work provides the first steps in the development of an implantable extender for treatment of SBS.

  2. Frequent Bowel Movements

    MedlinePlus

    ... bowel disease (IBD). Centers for Disease Control and Prevention. https://www.cdc.gov/ibd/what-is-IBD.htm. Accessed Nov. 15, 2017. Hyperthyroidism (Overactive thyroid). National Institute of Diabetes and Digestive ...

  3. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation.

    PubMed

    Walter, Benjamin Michael; Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-06-21

    In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective of this study was to assess the function of an automated text messaging (short message service, SMS)-supported colonoscopy preparation starting 4 days before colonoscopy appointment. After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging-provided information assessed by a questionnaire. Web-based SMS text messaging-supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging-based information was high. Using SMS for colonoscopy preparation with 4 days' guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy

  4. The influence of health literacy on comprehension of a colonoscopy preparation information leaflet

    PubMed Central

    Smith, Samuel G.; von Wagner, Christian; McGregor, Lesley M.; Curtis, Laura M.; Wilson, Elizabeth A. H.; Serper, Marina; Wolf, Michael S.

    2012-01-01

    BACKGROUND Successful bowel preparation is important for safe, efficacious, cost-effective colonoscopy procedures, however poor preparation is common. OBJECTIVE We sought to determine if there was an association between health literacy and comprehension of typical written instructions on how to prepare for a colonoscopy to enable more targeted interventions in this area. DESIGN Cross-sectional observational study SETTING Primary care clinics and federally qualified health centres in Chicago, Illinois. PATIENTS 764 participants (mean age: 63 years; Standard Deviation: 5.42) were recruited. The sample was from a mixed socio-demographic background and 71.9% of the participants were classified as having adequate health literacy scores. INTERVENTION 764 participants were presented with an information leaflet outlining the bowel preparatory instructions for colonoscopy. MAIN OUTCOME MEASURES Five questions assessing comprehension of the instructions in an ‘open book’ test. RESULTS Comprehension scores on the bowel preparation items were low. The mean number of items correctly answered was 3.2 (Standard Deviation, 1.2) out of a possible 5. Comprehensions scores overall and for each individual item differed significantly by health literacy level (all p<0.001). After controlling for gender, age, race, socio-economic status and previous colonoscopy experience in a multivariable model, health literacy was a significant predictor of comprehension (inadequate vs. adequate: β = −0.2; p < 0.001; marginal vs. adequate: β = −0.2; p < 0.001). LIMITATIONS The outcome represents a simulated task and not actual comprehension of preparation instructions for participants’ own recommended behavior. CONCLUSIONS Comprehension of a written colonoscopy preparation leaflet was generally low and significantly more so among people with low health literacy. Poor comprehension has implications for the safety and economic impact of gastroenterological procedures such as colonoscopy

  5. Women's experiences of living with neurogenic bladder and bowel after spinal cord injury: life controlled by bladder and bowel.

    PubMed

    Nevedal, Andrea; Kratz, Anna L; Tate, Denise G

    2016-01-01

    Neurogenic bladder and bowel (NBB) is a chronic condition hindering the functioning and quality of life (QOL) of people with spinal cord injury (SCI). NBB research has focused on men with SCI leaving unanswered questions about women's experiences of living with NBB. The purpose of this study was to identify and describe women's experiences of living with SCI and NBB. Secondary analysis of semi-structured interviews from a larger qualitative study of women with SCI (N = 50) was carried out. Transcripts were coded for bowel and bladder content. Pile-sorting techniques were used to identify emergent themes related to NBB. Meta-themes were categorized under the International Classification of Functioning, Disability and Health. Bladder and bowel topics were spontaneously discussed by 46 out of 50 study participants suggesting the salience of this issue for women with SCI. We identified 6 meta-themes: life controlled by bladder and bowel, bladder and bowel accidents, women's specific challenges, life course disruption, bladder and bowel medical management, and finding independence. Findings describe concerns, strategies, and the detrimental impact of NBB in the lives of women with SCI. Findings inform policy makers, health care and rehabilitation professionals to improve accessibility and quality of life for women with NBB. Women with spinal cord injury (SCI) reported gender specific challenges to living with neurogenic bladder and bowel (NBB). Interventions designed for women with SCI can address these problems and provide recommendations for prevention and treatment. Women described the detrimental impact of NBB on life course expectations, emotional, social, physical health, and quality of life domains. Psychosocial and educational programs can be developed to address these challenges and improve overall quality of life. Recommendations for special treatment and policy considerations are needed to maximize women's independence and health while living with NBB

  6. Peripolesis followed by cytotoxicity in chronic idiopathic inflammatory bowel disease.

    PubMed Central

    Wilders, M M; Drexhage, H A; Kokjé, M; Verspaget, H W; Meuwissen, S G

    1984-01-01

    Antigen presenting veiled cells have recently been described in cell suspensions prepared from the gut wall of patients with chronic idiopathic inflammatory bowel disease (CIBD). The normal gut wall is virtually devoid of these cells. In this report we describe a phenomenon known as peripolesis studied by phase contrast cinematography. This is a process in which lymphocytes are seen to wander around larger target cells. These could be identified ultrastructurally as Ia positive veiled cells. In most cases peripolesis was followed by lysis of the target cell. Peripolesis was recorded in cell suspensions of three out of seven patients with ulcerative colitis and in three out of nine patients with Crohn's disease; furthermore peripolesis was observed in one out of two patients with non-classifiable CIBD. In four cell suspensions showing peripolesis, cell lysis could be recorded and was especially striking in ulcerative colitis. Peripolesis involving veiled cells was previously described in delayed hypersensitivity reactions. This study lends support to the concept that delayed allergic reactivity plays a part in chronic inflammatory bowel disease. The antigens involved are, however, completely unknown. Images Fig. 1 Fig. 2 Fig. 3 PMID:6380839

  7. Non-invasive algorithm for bowel motility estimation using a back-propagation neural network model of bowel sounds.

    PubMed

    Kim, Keo-Sik; Seo, Jeong-Hwan; Song, Chul-Gyu

    2011-08-10

    Radiological scoring methods such as colon transit time (CTT) have been widely used for the assessment of bowel motility. However, these radiograph-based methods need cumbersome radiological instruments and their frequent exposure to radiation. Therefore, a non-invasive estimation algorithm of bowel motility, based on a back-propagation neural network (BPNN) model of bowel sounds (BS) obtained by an auscultation, was devised. Twelve healthy males (age: 24.8 ± 2.7 years) and 6 patients with spinal cord injury (6 males, age: 55.3 ± 7.1 years) were examined. BS signals generated during the digestive process were recorded from 3 colonic segments (ascending, descending and sigmoid colon), and then, the acoustical features (jitter and shimmer) of the individual BS segment were obtained. Only 6 features (J1, 3, J3, 3, S1, 2, S2, 1, S2, 2, S3, 2), which are highly correlated to the CTTs measured by the conventional method, were used as the features of the input vector for the BPNN. As a results, both the jitters and shimmers of the normal subjects were relatively higher than those of the patients, whereas the CTTs of the normal subjects were relatively lower than those of the patients (p < 0.01). Also, through k-fold cross validation, the correlation coefficient and mean average error between the CTTs measured by a conventional radiograph and the values estimated by our algorithm were 0.89 and 10.6 hours, respectively. The jitter and shimmer of the BS signals generated during the peristalsis could be clinically useful for the discriminative parameters of bowel motility. Also, the devised algorithm showed good potential for the continuous monitoring and estimation of bowel motility, instead of conventional radiography, and thus, it could be used as a complementary tool for the non-invasive measurement of bowel motility.

  8. In situ fabrication of hollow hydroxyapatite microspheres by phosphate solution immersion

    NASA Astrophysics Data System (ADS)

    Wang, Yingchun; Yao, Aihua; Huang, Wenhai; Wang, Deping; zhou, Jun

    2011-07-01

    Hollow hydroxyapatite (HAP) microspheres with pores on their surfaces were prepared by converting Li 2O-CaO-B 2O 3 (LCB) glass microspheres in phosphate solution. The structure, phase composition, surface morphology, and porosity of the hollow HAP microspheres were characterized by SEM, SEM-EDS, XRD, FTIR, ICP-AES, and N 2 adsorption-desorption techniques. The formation and conversion mechanism of the hollow HAP microspheres during immersion process were discussed. The as-prepared microspheres consisted of calcium deficient carbonated hydroxyapatite, which is biomimetic. FTIR spectra indicated that the resulting apatite were B-type CO 3HAP, in which carbonate ions occupied the phosphate sites. After 600 °C heating treatment, hollow microspheres were completely composed of calcium deficient hydroxyapatite crystals including CO32-. The pore size distribution of the as-prepared hollow HAP microspheres were mainly the mesopores in the range of 2-40 nm with the pore volume 0.5614 cm 3/g, and the mean pore size 10.5 nm, respectively. The results confirmed that LCB glass were transformed to hydroxyapatite without changing the external shape and dimension of the original glass object and the resulting microspheres possessed good hollow structures. Once immersed in phosphate solution, Ca-P-OH hydrates were in situ formed on the surface of the glass and precipitated in the position occupied by Ca 2+, while the pores were formed in the position occupied by Li + and B 3+. These hollow HAP microspheres with such structures may be used as promising drug delivery devices.

  9. Renal Involvement in Inflammatory Bowel Diseases.

    PubMed

    Corica, Domenico; Romano, Claudio

    2016-02-01

    The prevalence of extraintestinal manifestations in inflammatory bowel diseases varies from 6% to 46%. The aetiology of extraintestinal manifestations remains unclear. There are theories based on an immunological response influenced by genetic factors. Extraintestinal manifestations can involve almost every organ system. They may originate from the same pathophysiological mechanism of intestinal disease, or as secondary complications of inflammatory bowel diseases, or autoimmune diseases susceptibility. The most frequently involved organs are the joints, skin, eyes, liver and biliary tract. Renal involvement has been considered as an extraintestinal manifestation and has been described in both Crohn's disease and ulcerative colitis. The most frequent renal involvements in patients with inflammatory bowel disease are nephrolithiasis, tubulointerstitial nephritis, glomerulonephritis and amyloidosis. The aim of this review is to evaluate and report the most important data in the literature on renal involvement in patients with inflammatory bowel disease. Bibliographical searches were performed of the MEDLINE electronic database from January 1998 to January 2015 with the following key words (all fields): (inflammatory bowel disease OR Crohn's disease OR ulcerative colitis) AND (kidney OR renal OR nephrotoxicity OR renal function OR kidney disease OR renal disease OR glomerulonephritis OR interstitial nephritis OR amyloidosis OR kidney failure OR renal failure) AND (5-aminosalicylic acid OR aminosalicylate OR mesalazine OR TNF-α inhibitors OR cyclosporine OR azathioprine OR drugs OR pediatric). Copyright © 2015 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  10. A cross-cultural perspective on irritable bowel syndrome.

    PubMed

    Gerson, Charles D; Gerson, Mary-Joan

    2010-01-01

    Irritable bowel syndrome is a functional gastrointestinal illness, defined by symptoms. Irritable bowel syndrome has been described as a biopsychosocial condition, in which colonic dysfunction is affected by psychological and social factors. As a result of this unusual constellation, irritable bowel syndrome may be subject to cultural variables that differ in different parts of the globe. In this article, we describe some of the ways in which irritable bowel syndrome may be experienced differently, depending on local belief systems, psychological pressures, acceptance or resistance to a mind-body paradigm, and breakdown in support or relationship structure. Examples are given in which irritable bowel syndrome investigators from countries around the world describe various aspects of the syndrome that may affect the illness experience of their patients. We describe our own research studies that have demonstrated possible adverse effects on disease severity from relationship conflict, attribution of symptoms to physical rather than emotional cause, and the belief that irritable bowel syndrome is enduring and mysterious. Also described is our finding that symptom patterns may differ significantly between different geographic locations. Finally, we discuss the importance of "cultural competence" on the part of healthcare professionals in regard to caring for patients of diverse cultural backgrounds. © 2010 Mount Sinai School of Medicine.

  11. Bowel obstruction complicated by ischemia: analysis of CT findings.

    PubMed

    Cox, Veronica L; Tahvildari, Ali M; Johnson, Benjamin; Wei, Wei; Jeffrey, R Brooke

    2018-06-01

    To analyze CT signs of bowel ischemia in patients with surgical bowel obstruction, and thereby improve CT diagnosis in this common clinical scenario. Surgical and histopathological findings were used as the reference standard. We retrospectively analyzed CT findings in patients brought to surgery for bowel obstruction over 13 years. Etiology of obstruction (adhesion, hernia, etc.) was recorded. Specific CT features of acute mesenteric ischemia (AMI) were analyzed, including bowel wall thickening, mucosal hypoenhancement, and others. 173 cases were eligible for analysis. 21% of cases were positive for bowel ischemia. Volvulus, internal hernia, and closed-loop obstructions showed ischemia rates of 60%, 43%, and 43%; ischemia rate in obstruction from simple adhesion was 21%. Patients with bowel obstruction related to malignancy were never ischemic. Sensitivities and specificities for CT features predicting ischemia were calculated, with wall thickening, hypoenhancement, and pneumatosis showing high specificity for ischemia (86%-100%). Wall thickening, hypoenhancement, and pneumatosis are highly specific CT signs of ischemia in the setting of obstruction. None of the evaluated CT signs were found to be highly sensitive. Overall frequency of ischemia in surgical bowel obstruction is 21%, and 2-3 times that for complex obstructions (volvulus, closed loop, etc.). Obstructions related to malignancy virtually never become ischemic.

  12. OMOM capsule endoscopy in diagnosis of small bowel disease

    PubMed Central

    Li, Chen-yi; Zhang, Bing-ling; Chen, Chun-xiao; Li, You-ming

    2008-01-01

    Objective: To assess the diagnostic efficiency of OMOM capsule endoscopy (CE) in a group of patients with different indications. Methods: Data from 89 consecutive patients (49 males, 40 females) with suspected small bowel disease who underwent OMOM CE (Jinshan Science and Technology Company, Chongqing, China) examination were obtained by retrospective review. The patients’ indications of the disease consisted of the following: obscure gastrointestinal bleeding (OGIB), abdominal pain or diarrhea, partial intestinal obstruction, suspected inflammatory bowel disease, tumor of unknown origin, hypoproteinemia, constipation, weight loss, and elevated tumor markers. Results: CE failed in one patient. Visualization of the entire small bowel was achieved in 75.0%. Capsules were naturally excreted by all patients. The detection rate of abnormalities was 70.5% for patients with suspected small bowel disease, and the diagnostic yield for patients with OGIB was higher than that for patients with abdominal pain or diarrhea (85.7% vs 53.3%, P<0.005). Angiodysplasia was the most common small bowel finding. Active bleeding sites were noted in the small intestine in 11 cases. Conclusion: OMOM CE is a useful diagnostic tool for the diagnosis of variably suspected small bowel disease, whose diagnostic efficiency is similar to that of the Pillcam SB (small bowel) CE (Given Imaging, Yoqneam, Israel). PMID:18988304

  13. High- versus low-volume polyethylene glycol plus laxative versus sennosides for colonoscopy preparation in children.

    PubMed

    Kierkus, Jaroslaw; Horvath, Andrea; Szychta, Monika; Woynarowski, Marek; Wegner, Agnieszka; Wiernicka, Anna; Dadalski, Maciej; Teisseyre, Mikolaj; Dziechciarz, Piotr

    2013-08-01

    Many protocols of bowel preparation are available for use in children; however, none of them is commonly accepted. The aim of the study was to evaluate the efficacy and acceptability of high-volume polyethylene glycol (PEG) versus low-volume PEG combined with bisacodyl (BPEG) versus sennosides for colonoscopy preparation in children. Participants ages 10 to 18 years were randomly assigned to receive either PEG 60 or PEG 30 mL kg⁻¹ day⁻¹ plus oral bisacodyl 10 to 15 mg/day or sennosides 2 mg kg⁻¹ day⁻¹ for 2 days. A blinded assessment of bowel cleansing was made by the endoscopist according to the Aronchick and Ottawa scales. Patient acceptability was evaluated with the visual-analog scale. Analysis was done on an available case analysis basis. Of 240 patients enrolled in the study 234 patients were available for analysis of the efficacy of colon cleansing. There were no significant differences found among the 3 groups for the proportions of participants with excellent/good (PEG: 35/79, BPEG: 26/79, sennosides 25/76) and poor/inadequate (PEG: 20/79, BPEG: 28/79, sennosides 28/76) bowel preparation evaluated with the Aronchick scale and for the mean Ottawa total score (PEG: 5.47 ± 3.63, BPEG: 6.22 ± 3.3, sennosides: 6.18 ± 3.53). Acceptability of bowel cleansing protocol was similar in all of the groups (P = 0.8). All 3 cleansing methods showed similar efficacy and tolerability; however, none of them was satisfactory.

  14. Venous Small Bowel Infarction: Intraoperative Laser Doppler Flowmetry Discriminates Critical Blood Supply and Spares Bowel Length

    PubMed Central

    Käser, S. A.; Glauser, P. M.; Maurer, C. A.

    2012-01-01

    Introduction. In mesenteric infarction due to arterial occlusion, laser Doppler flowmetry and spectrometry are known reliable noninvasive methods for measuring microvascular blood flow and oxygen utilisation. Case Presentation. As an innovation we used these methods in a patient with acute extensive mesenteric infarction due to venous occlusion, occurring after radical right hemicolectomy. Aiming to avoid short bowel syndrome, we spared additional 110 cm of small bowel, instead of leaving only 80 centimetres of clinically viable small bowel in situ. The pathological examination showed only 5 mm of vital mucosa to be left distal to the dissection margin. No further interventions were necessary. Conclusion. Laser doppler flowmetry and spectrometry are potentially powerful methods to assist the surgeon's decision-making in critical venous mesenteric perfusion, thus having an important impact on clinical outcome. PMID:23093968

  15. An unexpected phosphate binding site in Glyceraldehyde 3-Phosphate Dehydrogenase: Crystal structures of apo, holo and ternary complex of Cryptosporidium parvum enzyme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, William J; Senkovich, Olga; Chattopadhyay, Debasish

    2009-06-08

    The structure, function and reaction mechanism of glyceraldehyde 3-phosphate dehydrogenase (GAPDH) have been extensively studied. Based on these studies, three anion binding sites have been identified, one 'Ps' site (for binding the C-3 phosphate of the substrate) and two sites, 'Pi' and 'new Pi', for inorganic phosphate. According to the original flip-flop model, the substrate phosphate group switches from the 'Pi' to the 'Ps' site during the multistep reaction. In light of the discovery of the 'new Pi' site, a modified flip-flop mechanism, in which the C-3 phosphate of the substrate binds to the 'new Pi' site and flips tomore » the 'Ps' site before the hydride transfer, was proposed. An alternative model based on a number of structures of B. stearothermophilus GAPDH ternary complexes (non-covalent and thioacyl intermediate) proposes that in the ternary Michaelis complex the C-3 phosphate binds to the 'Ps' site and flips from the 'Ps' to the 'new Pi' site during or after the redox step. We determined the crystal structure of Cryptosporidium parvum GAPDH in the apo and holo (enzyme + NAD) state and the structure of the ternary enzyme-cofactor-substrate complex using an active site mutant enzyme. The C. parvum GAPDH complex was prepared by pre-incubating the enzyme with substrate and cofactor, thereby allowing free movement of the protein structure and substrate molecules during their initial encounter. Sulfate and phosphate ions were excluded from purification and crystallization steps. The quality of the electron density map at 2{angstrom} resolution allowed unambiguous positioning of the substrate. In three subunits of the homotetramer the C-3 phosphate group of the non-covalently bound substrate is in the 'new Pi' site. A concomitant movement of the phosphate binding loop is observed in these three subunits. In the fourth subunit the C-3 phosphate occupies an unexpected site not seen before and the phosphate binding loop remains in the substrate

  16. Characterization of calcium phosphate powders originating from Phyllacanthus imperialis and Trochidae Infundibulum concavus marine shells.

    PubMed

    Tămăşan, M; Ozyegin, L S; Oktar, F N; Simon, V

    2013-07-01

    The study reports the preparation and characterization of powders consisting of the different phases of calcium phosphates that were obtained from the naturally derived raw materials of sea-shell origins reacted with H3PO4. Species of sea origin, such as corals and nacres, attracted a special interest in bone tissue engineering area. Nacre shells are built up of calcium carbonate in aragonite form crystallized in an organic matrix. In this work two natural marine origin materials (shells of echinoderm Sputnik sea urchin - Phyllacanthus imperialis and Trochidae Infundibulum concavus mollusk) were involved in the developing powders of calcium phosphate based biomaterials (as raw materials for bone-scaffolds) by hotplate and ultrasound methods. Thermal analyses of the as-prepared materials were made for an assessment of the thermal behavior and heat treatment temperatures. Samples from both sea shells each of them prepared by the above mentioned methods were subjected to thermal treatments at 450 °C and 850 °C in order to evaluate the crystalline transformations of the calcium phosphate structures in the heating process. By X-ray diffraction analyses various calcium phosphate phases were identified. In Sputnik sea urchins originated samples were found predominantly brushite and calcite as a small secondary phase, while in Trochidae I. concavus samples mainly monetite and HA phases were identified. Thermal treatment at 850 °C resulted flat-plate whitlockite crystals - β-MgTCP [(Ca, Mg)3 (PO4)2] for both samples regardless the preparation method (ultrasound or hotplate) or the targeted Ca/P molar ratio according with XRD patterns. Scanning electron microscopy and Fourier transformed infrared spectroscopy were involved more in the characterization of these materials and the good correlations of the results of these methods were made. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Rheological and Mechanical Properties of Thermoresponsive Methylcellulose/Calcium Phosphate-Based Injectable Bone Substitutes.

    PubMed

    Demir Oğuz, Öznur; Ege, Duygu

    2018-04-14

    In this study, a novel injectable bone substitute (IBS) was prepared by incorporating a bioceramic powder in a polymeric solution comprising of methylcellulose (MC), gelatin and citric acid. Methylcellulose was utilized as the polymeric matrix due to its thermoresponsive properties and biocompatibility. 2.5 wt % gelatin and 3 wt % citric acid were added to the MC to adjust the rheological properties of the prepared IBS. Then, 0, 20, 30 and 50 wt % of the bioceramic component comprising tetracalcium phosphate/hydroxyapatite (TTCP/HA), dicalcium phosphate dehydrate (DCPD) and calcium sulfate dehydrate (CSD) were added into the prepared polymeric component. The prepared IBS samples had a chewing gum-like consistency. IBS samples were investigated in terms of their chemical structure, rheological characteristics, and mechanical properties. After that, in vitro degradation studies were carried out by measurement of pH and % remaining weight. Viscoelastic characteristics of the samples indicated that all of the prepared IBS were injectable and they hardened at approximately 37 °C. Moreover, with increasing wt % of the bioceramic component, the degradation rate of the samples significantly reduced and the mechanical properties were improved. Therefore, the experimental results indicated that the P50 mix may be a promising candidates to fill bone defects and assist bone recovery for non-load bearing applications.

  18. Rheological and Mechanical Properties of Thermoresponsive Methylcellulose/Calcium Phosphate-Based Injectable Bone Substitutes

    PubMed Central

    2018-01-01

    In this study, a novel injectable bone substitute (IBS) was prepared by incorporating a bioceramic powder in a polymeric solution comprising of methylcellulose (MC), gelatin and citric acid. Methylcellulose was utilized as the polymeric matrix due to its thermoresponsive properties and biocompatibility. 2.5 wt % gelatin and 3 wt % citric acid were added to the MC to adjust the rheological properties of the prepared IBS. Then, 0, 20, 30 and 50 wt % of the bioceramic component comprising tetracalcium phosphate/hydroxyapatite (TTCP/HA), dicalcium phosphate dehydrate (DCPD) and calcium sulfate dehydrate (CSD) were added into the prepared polymeric component. The prepared IBS samples had a chewing gum-like consistency. IBS samples were investigated in terms of their chemical structure, rheological characteristics, and mechanical properties. After that, in vitro degradation studies were carried out by measurement of pH and % remaining weight. Viscoelastic characteristics of the samples indicated that all of the prepared IBS were injectable and they hardened at approximately 37 °C. Moreover, with increasing wt % of the bioceramic component, the degradation rate of the samples significantly reduced and the mechanical properties were improved. Therefore, the experimental results indicated that the P50 mix may be a promising candidates to fill bone defects and assist bone recovery for non-load bearing applications. PMID:29662018

  19. Tb3+ and Eu3+ doped zinc phosphate glasses for solid state lighting applications

    NASA Astrophysics Data System (ADS)

    Jha, Kaushal; Vishwakarma, Amit K.; Jayasimhadri, M.; Haranath, D.; Jang, Kiwan

    2018-04-01

    Tb3+ and Eu3+ doped zinc phosphate (ZP) glasses were prepared by conventional melt-quenching technique and their photoluminescence properties were investigated in detail. For, Tb3+ doped glasses the intense emission was at 545 nm corresponding to 5D4→7F5 transition under 377 nm n-UV excitation. The optimized concentration for Tb3+ doped zinc phosphate glass was 3 mol% and above this concentration quenching takes place. The Eu3+ doped zinc phosphate glass revealed intense emission at 613 nm attributed to the 5D0→7F2 transition under intense 392 nm n-UV excitation. The concentration quenching phenomenon was not observed in the Eu3+ doped ZP glasses. The CIE chromaticity coordinates for 3 mol% Tb3+ and 5 mol% Eu3+ doped ZP glasses were found to (0.283, 0.615) and (0.652, 0.331) lying in the green and red regions, respectively. The above mentioned results indicate that the prepared glass are suitable for application in the field of lighting and display devices.

  20. Mechanical Extension Implants for Short-Bowel Syndrome

    PubMed Central

    Luntz, Jonathan; Brei, Diann; Teitelbaum, Daniel; Spencer, Ariel

    2007-01-01

    Short-bowel syndrome (SBS) is a rare, potentially lethal medical condition where the small intestine is far shorter than required for proper nutrient absorption. Current treatment, including nutritional, hormone-based, and surgical modification, have limited success resulting in 30% to 50% mortality rates. Recent advances in mechanotransduction, stressing the bowel to induce growth, show great promise; but for successful clinical use, more sophisticated devices that can be implanted are required. This paper presents two novel devices that are capable of the long-term gentle stressing. A prototype of each device was designed to fit inside a short section of bowel and slowly extend, allowing the bowel section to grow approximately double its initial length. The first device achieves this through a dual concentric hydraulic piston that generated almost 2-fold growth of a pig small intestine. For a fully implantable extender, a second device was developed based upon a shape memory alloy actuated linear ratchet. The proof-of-concept prototype demonstrated significant force generation and almost double extension when tested on the benchtop and inside an ex-vivo section of pig bowel. This work provides the first steps in the development of an implantable extender for treatment of SBS. PMID:17369875

  1. Microbial solubilization of phosphate

    DOEpatents

    Rogers, R.D.; Wolfram, J.H.

    1993-10-26

    A process is provided for solubilizing phosphate from phosphate containing ore by treatment with microorganisms which comprises forming an aqueous mixture of phosphate ore, microorganisms operable for solubilizing phosphate from the phosphate ore and maintaining the aqueous mixture for a period of time and under conditions operable to effect the microbial solubilization process. An aqueous solution containing soluble phosphorus can be separated from the reacted mixture by precipitation, solvent extraction, selective membrane, exchange resin or gravity methods to recover phosphate from the aqueous solution. 6 figures.

  2. Microbial solubilization of phosphate

    DOEpatents

    Rogers, Robert D.; Wolfram, James H.

    1993-01-01

    A process is provided for solubilizing phosphate from phosphate containing ore by treatment with microorganisms which comprises forming an aqueous mixture of phosphate ore, microorganisms operable for solubilizing phosphate from the phosphate ore and maintaining the aqueous mixture for a period of time and under conditions operable to effect the microbial solubilization process. An aqueous solution containing soluble phosphorous can be separated from the reacted mixture by precipitation, solvent extraction, selective membrane, exchange resin or gravity methods to recover phosphate from the aqueous solution.

  3. Isolation, purification, and characterization of glucosamine-6-phosphate-N-acetylase from pig liver.

    PubMed

    Porowski, T S; Porowska, H; Gałasiński, W

    1990-08-01

    The procedure of isolation, purification, and characterization of glucosamine-6-phosphate acetylase from the pig liver is described. The steps of purification were as follows: adsorption on hydroxylapatite, fractionation with ammonium sulfate, chromatography on cellulose phosphate, electrofocusing, and preparative gel electrophoresis. A highly purified (about 3000-fold) preparation of GlcN-6-P acetylase, with a yield of 23%, was obtained. It was found that GlcN-6-P acetylase from pig liver is heterogeneous and exists in two active forms. The characteristic features of the preparation were established: Mr, about 24 kDa; temperature optimum at 37 degrees; pH optimum at 7.45; and Km (GlcN-6-P) 3.7 x 10(-3) M and Km (AcCoA) 1.4 x 10(-3) M. The ions K+, Na+, NH4+, Mg2+, Mn2+, and CH3COO- do not stimulate the acetylase activity. The product of acetylase reaction (GlcNAc-6-P) inhibits this reaction according to the feedback process. The highly purified preparation of GlcN-6-P acetylase is unstable during storage and it is protected by ampholine or glycine from enzyme inactivation, but it is not protected by 2-mercaptoethanol.

  4. Biomimetic evaluation of β tricalcium phosphate prepared by hot isostatic pressing

    PubMed Central

    Mateescu, Mihaela; Rguitti, Emmanuelle; Ponche, Arnaud; Descamps, Michel; Anselme, Karine

    2012-01-01

    Two types of completely densified β-TCP tablets were synthesized from a stoichiometric β-TCP powder. The first ones (TCP) were conventionally sintered, while the second ones (TCP-T) were sintered and treated by hot isostatic process (HIP). The HIP produced completely densified materials with relative densities greater than 99.9% and a transparent appearance of tablets. Samples were immersed in culture medium with (CM) or without serum (NCM) in static and dynamic conditions for a biomimetic evaluation. Similarly, SaOs-2 cells were cultured on samples in a static or dynamic flow perfusion system. The results of surface transformation in absence of cells showed that the dynamic condition increased the speed of calcium phosphate precipitations compared with the static condition. The morphology of precipitates was different with nature of tablets. The immersion in CM did impede this precipitation. XPS analysis of TCP-T tablets showed the presence of hydroxyapatite (HA) precipitates after incubation in NCM while octacalcium phosphate (OCP) precipitates were formed after incubation in CM. The analysis of the response of SaOs-2 cells on surfaces showed that the two types of materials are biocompatible. However, the dynamic mode of culture stimulated the differentiation of cells. Finally, it appears that the HIP treatment of TCP produces highly densified and transparent samples that display a good in vitro biocompatibility in static and dynamic culture conditions. Moreover, an interesting result of this work is the relationship between the presence of proteins in the immersion medium and the quality of precipitates formed on hipped TCP surface. PMID:23507861

  5. Herbal medicines for the management of irritable bowel syndrome: A comprehensive review

    PubMed Central

    Rahimi, Roja; Abdollahi, Mohammad

    2012-01-01

    Irritable bowel syndrome (IBS) is a functional gut disorder with high prevalence. Because of various factors involved in its pathophysiology and disappointing results from conventional IBS medications, the treatment of IBS is challenging and use of complementary and alternative medicines especially herbal therapies is increasing. In this paper, electronic databases including PubMed, Scopus, and Cochrane library were searched to obtain any in vitro, in vivo or human studies evaluating single or compound herbal preparations in the management of IBS. One in vitro, 3 in vivo and 23 human studies were included and systematically reviewed. The majority of studies are about essential oil of Menta piperita as a single preparation and STW 5 as a compound preparation. Some evaluated herbs such as Curcuma xanthorriza and Fumaria officinalis did not demonstrate any benefits in IBS. However, it seems there are many other herbal preparations such as those proposed in traditional medicine of different countries that could be studied and investigated for their efficacy in management of IBS. PMID:22363129

  6. Educational strategies for colonoscopy bowel prep overcome barriers against split-dosing: A randomized controlled trial

    PubMed Central

    Andrealli, Alida; Paggi, Silvia; Amato, Arnaldo; Rondonotti, Emanuele; Imperiali, Gianni; Lenoci, Nicoletta; Mandelli, Giovanna; Terreni, Natalia; Spinzi, Giancarlo; Radaelli, Franco

    2018-01-01

    Background A split-dose (SD) regimen is crucial for colonoscopy quality. Compliance with SD for early morning colonoscopy is generally poor. The present study evaluated whether pre-colonoscopy counselling, in addition to a dedicated leaflet, might increase SD uptake. Methods Consecutive 50–69-year-old patients undergoing screening colonoscopy before 10 a.m. were randomized to either receive written information only on bowel preparation (Written Group, WG) or written and oral instructions (Written and Oral Group, WaOG). The leaflet strongly encouraged SD adoption. The primary endpoint was the number of patients adopting SD in each group. The secondary endpoints were predictors of SD uptake, compliance with preparation schemes and cleansing adequacy. Results A total of 286 patients (143 WG, 143 WaOG) were enrolled (mean age 59.6 ± 6.1 years, men 49.3%). SD was adopted by 114 and 125 patients in the WG and WaOG, respectively (79.7% versus 87.4%, p = 0.079). No significant differences were observed for the proportion of patients with full compliance with preparation scheme (97.9% versus 97.2%, p = 0.99) and of procedures with adequate bowel cleansing (95.6% versus 95.1%, p = 0.77). At multivariate analysis, a > 1 h travel time to the endoscopy service was inversely correlated with SD uptake (odds ratio (OR) 0.30, 95% confidence interval (CI) 0.09–0.98). Conclusions Our leaflet guaranteed satisfactory uptake of SD and excellent adherence to the preparation scheme for early morning colonoscopy. Its use might marginalize the need for additional oral instructions, particularly in open-access settings. PMID:29511558

  7. Primary malignant small bowel tumors: an atypical abdominal emergency.

    PubMed Central

    Mitchell, K. J.; Williams, E. S.; Leffall, L. D.

    1995-01-01

    Primary malignant tumors of the small bowel are uncommon in the United States. They comprise less than 1% of all gastrointestinal malignancies, with an incidence of 2200 cases per year. The clinical presentation of small bowel tumors is frequently insidious and often overlooked by physicians. The low incidence and lack of pathognomonic symptoms are the reasons that the early diagnosis of malignant small bowel tumor is uncommon. To better understand the clinical presentation, diagnostic evaluation, management, and outcome, a review of Howard University patients with primary malignant small bowel tumors between 1970 and 1990 was conducted. Our experience concurs with the reported literature and supports the conclusion that a high index of suspicion is necessary. The diagnosis of a malignant small bowel tumor should be considered in patients with vague chronic abdominal complaints. Images Figure 1 Figure 2 PMID:7752280

  8. Bowel Angioedema Associated With Iodinated Contrast Media: Incidence and Predisposing Factors.

    PubMed

    Seo, Nieun; Chung, Yong Eun; Lim, Joon Seok; Song, Mi Kyung; Kim, Myeong-Jin; Kim, Ki Whang

    2017-09-01

    Bowel angioedema is an acute adverse reaction to iodinated contrast media (CM) that involves the gastrointestinal tract. We aimed to investigate the incidence and predisposing factors of iodinated CM-associated bowel angioedema during computed tomography (CT) examinations. This study was approved by our institutional review board, and informed consent was waived due to its retrospective design. From July 2013 to July 2015, adult patients with a history of adverse reactions to iodinated CM during CT (group A, n = 427) and patients without adverse reactions matched for age and sex with the propensity-score matching method (group B, n = 427) were studied. Contrast media-associated bowel angioedema was determined when bowel wall thickness increased after contrast enhancement compared with the precontrast scan. Potential predisposing factors including patient demographics, symptoms and time of adverse reactions, and CM-related factors were compared between patients with and without angioedema in group A. In addition, the incidence of bowel angioedema was compared between groups A and B. The incidence of CM-associated bowel angioedema in group A was 3.3% (14/427) in the per-patient analysis and 2.6% (15/578) in the per-examination analysis. The CM-associated bowel angioedema involved the distal duodenum and/or proximal jejunum and showed long-segmental circumferential bowel wall thickening on CT. None of the studied predisposing factors was different between patients with and without bowel angioedema (P > 0.05). The incidence of CM-associated bowel angioedema in group B was 1.9% (8/427) and 1.7% (8/458) for per-patient and per-examination analyses, respectively, and these rates were not significantly different between groups A and B (P = 0.346 and P = 0.370, respectively). The incidence of CM-associated bowel angioedema during CT was 1.7% to 3.3%, and none of the studied predisposing factors was associated with bowel angioedema.

  9. The Preparation of Capsaicin-Chitosan Microspheres (CCMS) Enteric Coated Tablets

    PubMed Central

    Chen, Jian; Huang, Gui-Dong; Tan, Si-Rong; Guo, Jiao; Su, Zheng-Quan

    2013-01-01

    This study aimed to research the preparation and content determination of capsaicin-chitosan microspheres (CCMS) enteric coated tablets. The core tablets were prepared with the method of wet granulation. Nine formulae were designed to determine the optimal formula of the core tablet. Eudragit L100 was used to prepare the CCMS enteric-coated tablets. The effect of enteric coated formulation variables such as content of talc (10%, 25% and 40%), plasticisers (TEC and DBS), dosage of plasticiser (10%, 20% and 30%) and coating weight (2%, 3% and 5%) were evaluated for drug release characteristics. The in vitro release was studied using 0.1 N HCl and pH 6.8 phosphate buffer. Enteric coated tablets without ruptures or swelling behaviour over 2 h in 0.1 N HCl indicated that these tablets showed acid resistance. The accumulated release rate in phosphate buffer (pH 6.8) revealed that the prepared tablets were able to sustain drug release into the intestine and a first-order release was obtained for capsaicin. This research is the first report of the preparation and content determination of CCMS enteric coated tablets. The sustained release behavior of enteric coated formulations in pH 6.8 phosphate buffer demonstrated that it would be a potential drug delivery platform for sustained delivery of gastric irritant drugs. PMID:24351818

  10. Small Bowel Obstruction Caused by Aloe vera Bezoars: A Case Report.

    PubMed

    Hong, In Taik; Cha, Jae Myung; Ki, Hye Jin; Kwak, Min Seob; Yoon, Jin Young; Shin, Hyun Phil; Jeoun, Jung Won; Choi, Sung Il

    2017-05-25

    Small bowel obstruction is a clinical condition commonly caused by postoperative adhesion, volvulus, intussusceptions, and hernia. Small bowel obstruction due to bezoars is clinically uncommon, accounting for approximately 2-4% of all obstructions. Computed tomography (CT) is a useful method in diagnosing the cause of small bowel obstruction. However, small bowel obstruction caused by bezoars may not be detected by an abdominal CT examination. Herein, we report a rare case of small bowel obstruction by Aloe vera bezoars, which were undetected by an abdominal CT. Phytobezoars should be included in the differential diagnosis of small bowel obstruction in patients with predisposing factors, such as excessive consumption of high-fiber food and diabetes.

  11. Tailoring the structure of biphasic calcium phosphate via synthesis procedure

    NASA Astrophysics Data System (ADS)

    Mansour, S. F.; El-dek, S. I.; Ahmed, M. K.

    2017-12-01

    Nano calcium phosphate ceramics (CaPC) were synthesized using simple co-precipitation method at different preparation conditions. The selected Ca/P ratio with a variation of pH value lead to formation of dicalcium phosphate dihydrate (DCPD) at pH 5 and 6 while, hydroxyapatite (HAP) nano particles were formed at pH 9 and 12 at room temperature. The crystallite size was in the range of 15-55 nm depending on the obtained crystalline phase. The study displayed variation of decomposition depending on the annealing temperature. The significant note is the different transformation trend of each phase depending on the starting pH value. The HRTEM illustrated that the DCPD phase was formed as fibers with diameter around 4-6 nm, while HAP was formed in rod shape. The aspect ratio decreased from 6.6 at pH 9 to 4 at pH 12 which refer to the great influence of pH value on the morphology of calcium phosphates.

  12. An Overview of Bowel Incontinence: What Can Go Wrong?

    ERIC Educational Resources Information Center

    Norton, William F.

    2008-01-01

    Bowel incontinence, also called fecal incontinence, is the loss of control over liquid or solid stools. It can occur at any age--as a child, teenager, or adult. Severity can range from infrequent leakage of a small amount of stool to total loss of bowel control. Some persons might feel the urge to have a bowel movement but be unable to control it…

  13. [Bowel-associated dermatosis-arthritis syndrome during ulcerative colitis: A rare extra-intestinal sign of inflammatory bowel disease].

    PubMed

    Aounallah, A; Zerriaa, S; Ksiaa, M; Jaziri, H; Boussofara, L; Ghariani, N; Mokni, S; Saidi, W; Sriha, B; Belajouza, C; Denguezli, M; Nouira, R

    2016-05-01

    Bowel-associated dermatosis-arthritis syndrome (BADAS) is characterized by combined pustular skin eruption and arthralgia. It may be associated with inflammatory bowel disease or bowel bypass surgery. We report a case of BADAS in a patient with ulcerative colitis. A 39-year-old woman was being treated for a severe flare-up of ulcerative colitis present over the preceding 2 months and treated with prednisone, azathioprine and cyclosporine. She was also presenting a cutaneous eruption and arthralgia that had begun three days earlier. Dermatological examination revealed profuse vesicular and pustular lesions. Biopsy specimens showed mature neutrophilic infiltrate within the dermis. A diagnosis of BADAS was made and the same treatment was maintained. Systemic symptoms were resolved but the vesicular lesions were superseded by hypertrophic scars. Bowel-associated dermatosis-arthritis syndrome consists of a vesiculopustular eruption associated with arthralgia and/or arthritis and fever, as was the case in our patient. The histological picture is characterized by abundant neutrophilic infiltrate in the superficial dermis. The clinical and histological features and the course of BADAS allow this entity to be classified within the spectrum of neutrophilic dermatoses. Treatment chiefly involves systemic corticosteroids. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Preparation of Calcium Phosphate Cement and Polymethyl Methacrylate for Biological Composite Bone Cements

    PubMed Central

    Yang, Jun; Zhang, Kairui; Zhang, Sheng; Fan, Jiping; Guo, Xinhui; Dong, Weiqiang; Wang, Shengnan; Chen, Yirong; Yu, Bin

    2015-01-01

    Background We studied the biological safety, biomechanics, and tissue compatibility of calcium phosphate cement and Polymethyl Methacrylate composite bone cement mixed in different ratios. Material/Methods CPC and PMMA were mixed in different ratios (3: 1, 2: 1, 1: 1, 1: 2, 1: 5, 1: 10, 1: 15, and 1: 20). PMMA solvent is a general solvent containing a dissolved preparation of the composite bone cement specific to a given specimen to determine biological safety, biomechanics, and tissue compatibility. Results The CPC/PMMA (33%) group, CPC/PMMA (50%) group, CPC/PMMA (67%) group, and CPC/PMMA (75%) group were more in line with the composite bone cement without cytotoxicity requirements. The compressive strength of the CPC/PMMA (67%) group and CPC/PMMA (75%) group was 20Mpa–30Mpa, while that of the CPC/PMMA (4.8%) group, CPC/PMMA (6.25%) group, CPC/PMMA (9.1%) group, CPC/PMMA (16.7%) group, CPC/PMMA (33%) group, and CPC/PMMA (50%) group was 40Mpa–70Mpa. Curing time was longer in the CPC group (more than 11 min) and shorter in the PMMA group (less than 2 min). The results of weight loss rate showed that there were no significant differences between the CPC/PMMA group (4.8%, 6.25%, 9.1%, 16.7%, 33%) and PMMA control group (p>0.05). With the decrease of CPC content, the rate of weight loss gradually decreased. Conclusions The CPC/PMMA (50%) group, CPC/PMMA (67%) group, and CPC/PMMA (75%) group provide greater variability and selectivity for the composite bone cement in obtaining better application. PMID:25904398

  15. Same-day 2-L PEG-citrate-simethicone plus bisacodyl vs split 4-L PEG: Bowel cleansing for late-morning colonoscopy

    PubMed Central

    de Leone, Annalisa; Tamayo, Darina; Fiori, Giancarla; Ravizza, Davide; Trovato, Cristina; De Roberto, Giuseppe; Fazzini, Linda; Dal Fante, Marco; Crosta, Cristiano

    2013-01-01

    AIM: To evaluate the efficacy, tolerability, acceptability and feasibility of bisacodyl plus low volume polyethyleneglycol-citrate-simeticone (2-L PEG-CS) taken the same day as compared with conventional split-dose 4-L PEG for late morning colonoscopy. METHODS: Randomised, observer-blind, parallel group, comparative trial carried out in 2 centres. Out patients of both sexes, aged between 18 and 85 years, undergoing colonoscopy for diagnostic investigation, colorectal cancer screening or follow-up were eligible. The PEG-CS group received 3 bisacodyl tablets (4 tablets for patients with constipation) at bedtime and 2-L PEG-CS in the morning starting 5 h before colonoscopy. The control group received a conventional 4-L PEG formulation given as split regimen; the morning dose was taken with the same schedule of the low volume preparation. The Ottawa Bowel Preparation Scale (OBPS) score was used as the main outcome measure. RESULTS: A total of 164 subjects were enrolled and 154 completed the study; 78 in the PEG-CS group and 76 in the split 4-L PEG group. The two groups were comparable at baseline. The OBPS score in the PEG-CS group (3.09 ± 2.40) and in the PEG group (2.39 ± 2.55) were equivalent (difference +0.70; 95%CI: -0.09-1.48). This was confirmed by the rate of successful bowel cleansing in the PEG-CS group (89.7%) and in the PEG group (92.1%) (difference -2.4%; 95%CI: -11.40- 6.70). PEG-CS was superior in terms of mucosa visibility compared to PEG (85.7% vs 72.4%, P = 0.042). There were no significant differences in caecum intubation rate, time to reach the caecum and withdrawal time between the two groups. The adenoma detection rate was similar (PEG-CS 43.6% vs PEG 44.7%). No serious adverse events occurred. No difference was found in tolerability of the bowel preparations. Compliance was equal in both groups: more than 90% of subjects drunk the whole solution. Willingness to repeat the same bowel preparations was about 90% for both regimes. CONCLUSION: Same

  16. Small bowel volvulus with jejunal diverticulum: Primary or secondary?

    PubMed

    Shen, Xiao-Fei; Guan, Wen-Xian; Cao, Ke; Wang, Hao; Du, Jun-Feng

    2015-09-28

    Small bowel volvulus, which is torsion of the small bowel and its mesentery, is a medical emergency, and is categorized as primary or secondary type. Primary type often occurs without any apparent intrinsic anatomical anomalies, while the secondary type is common clinically and could be caused by numerous factors including postoperative adhesions, intestinal diverticulum, and/or tumors. Here, we report a rare case of a 60-year-old man diagnosed with small bowel volvulus using multidetector computed tomography (MDCT) angiography. Further discovery by laparotomy showed one jejunal diverticulum, longer corresponding mesentery with a narrower insertion, and a lack of mesenteric fat. This case report includes several etiological factors of small bowel volvulus, and we discuss the possible cause of small bowel volvulus in this patient. We also highlight the importance of MDCT angiography in the diagnosis of volvulus and share our experience in treating this disease.

  17. Small bowel volvulus with jejunal diverticulum: Primary or secondary?

    PubMed Central

    Shen, Xiao-Fei; Guan, Wen-Xian; Cao, Ke; Wang, Hao; Du, Jun-Feng

    2015-01-01

    Small bowel volvulus, which is torsion of the small bowel and its mesentery, is a medical emergency, and is categorized as primary or secondary type. Primary type often occurs without any apparent intrinsic anatomical anomalies, while the secondary type is common clinically and could be caused by numerous factors including postoperative adhesions, intestinal diverticulum, and/or tumors. Here, we report a rare case of a 60-year-old man diagnosed with small bowel volvulus using multidetector computed tomography (MDCT) angiography. Further discovery by laparotomy showed one jejunal diverticulum, longer corresponding mesentery with a narrower insertion, and a lack of mesenteric fat. This case report includes several etiological factors of small bowel volvulus, and we discuss the possible cause of small bowel volvulus in this patient. We also highlight the importance of MDCT angiography in the diagnosis of volvulus and share our experience in treating this disease. PMID:26420976

  18. The effects of oral liquid and intravenous glutamine on bowel adaptation in a rabbit short bowel syndrome model.

    PubMed

    Tekın, Ahmet; Yemış, Mustafa; Küçükkartallar, Tevfik; Vatansever, Celalettin; Çakir, Murat; Yilmaz, Hüseyin; Toy, Hatice; Özer, Şükru

    2010-09-01

    The aim of this study was to examine whether liquid glutamine given to rabbits after resection is as effective as intravenous (i.v.) glutamine and to study the positive effects of glutamine on mucosal atrophy that occurs after bowel resection. Thirty rabbits with an average weight of 2500 g were used. On the third day, 30 rabbits were divided into three groups as follows: Group I (controls): bowel resection + oral total parenteral nutrition, Group II (oral liquid L-glutamine): Bowel resection + oral total parenteral nutrition + oral liquid L-glutamine, and Group III (i.v. L-glutamine): bowel resection + oral total parenteral nutrition + i.v. L-glutamine. On the postoperative 7th day, all subjects were sacrificed to examine intestinal adaptation indicators. There was an increase in average villus height and crypt depth in Group III compared to the other groups (p=0.0001). In Group II, the villus height and crypt depth increased more than in Group I, but the difference was less significant (p=0.038). There was no significant difference between groups in terms of average goblet cell proliferation. In our experimental study, it was observed that the orally given L-glutamine liquid in the rabbit intestinal adaptation model prevented mucosal atrophy after 50% bowel resection and even increased mucosa mass. However, i.v. glutamine led to similar and even better results. Neither route of glutamine administration was determined to have an effect on goblet cell proliferation.

  19. Polyethylene glycol powder solution versus senna for bowel preparation for colonoscopy in children.

    PubMed

    Terry, Natalie A; Chen-Lim, Mei Lin; Ely, Elizabeth; Jatla, Muralidhar; Ciavardone, Denise; Esch, Salina; Farace, Lisa; Jannelli, Frances; Puma, Anita; Carlow, Dean; Mamula, Petar

    2013-02-01

    Safety and effectiveness of large-volume polyethylene glycol-based solution (PEG-ES) have been documented, but the taste and volume can be barriers to successful colonoscopy preparation. Efficacy and safety of small-volume electrolyte-free (PEG-P) preparation (Miralax) for colonoscopy preparation have been rarely studied, although presently used at many pediatric centers. The primary objective of the present study was to determine whether PEG-P results in a more efficacious and safe colonoscopy preparation as compared with senna. The study design was prospective, randomized, and single-blinded. Patients ages 6 to 21 years were randomized to a 2-day clean-out regimen of PEG-P at a dose of 1.5 g/kg divided twice per day for 2 days versus senna 15 mL daily (ages 6-12) or 30 mL daily (ages 12-21) for 2 days. Both preparations required 1 day of clear liquids whereas senna preparation required an additional day of full liquid diet. A blinded endoscopist graded the quality of preparation with a standardized cleanliness tool (Aronchick scale). Serum chemistry panels were obtained. Patients or parents rated symptoms and ease of preparation. The anticipated number of subjects was 166; however, the interim analysis demonstrated inferiority of senna preparation. Thirty patients were evaluated in the present study. Of the patients in the PEG-P arm, 88% (14/16) received an excellent/good score compared with 29% (4/14), with the senna preparation (P = 0.0022). Both preparations were well-tolerated by patient-graded ease of preparation. Demographics and laboratory values did not differ significantly across the 2 groups. No serious adverse events were noted. PEG-P is an effective colonoscopy preparation whereas senna preparation was insufficient. Both were well-tolerated and appear safe in a pediatric population.

  20. Activity of Escherichia coli, Aspergillus niger, and Rye Phytase toward Partially Phosphorylated myo-Inositol Phosphates.

    PubMed

    Greiner, Ralf

    2017-11-08

    Kinetic parameters for the dephosphorylation of sodium phytate and a series of partially phosphorylated myo-inositol phosphates were determined at pH 3.0 and pH 5.0 for three phytase preparations (Aspergillus niger, Escherichia coli, rye). The enzymes showed lower affinity and turnover numbers at pH 3 compared to pH 5 toward all myo-inositol phosphates included in the study. The number and distribution of phosphate groups on the myo-inositol ring affected the kinetic parameters. Representatives of the individual phytate dephosphorylation pathways were identified as the best substrates of the phytases. Within the individual phytate dephosphorylation pathways, the pentakisphosphates were better substrates compared to the tetrakisphosphates or phytate itself. E. coli and rye phytase showed comparable activities at both pH values toward the tetrakis- and trisphosphate, whereas A. niger phytase exhibited a higher activity toward the tetrakisphosphate. A myo-inositol phosphate with alternate phosphate groups was shown to be not significantly dephosphorylated by the phytases.

  1. Calcium phosphate coating on magnesium alloy for modification of degradation behavior

    NASA Astrophysics Data System (ADS)

    Cui, Fu-zhai; Yang, Jing-xin; Jiao, Yan-peng; Yin, Qing-shui; Zhang, Yu; Lee, In-Seop

    2008-06-01

    Magnesium alloy has similar mechanical properties with natural bone, but its high susceptibility to corrosion has limited its application in orthopedics. In this study, a calcium phosphate coating is formed on magnesium alloy (AZ31) to control its degradation rate and enhance its bioactivity and bone inductivity. Samples of AZ31 plate were placed in the supersaturated calcification solution prepared with Ca(NO3)2, NaH2PO4 and NaHCO3, then the calcium phosphate coating formed. Through adjusting the immersion time, the thickness of uniform coatings can be changed from 10 to 20 μm. The composition, phase structure and morphology of the coatings were investigated. Bonding strength of the coatings and substrate was 2-4 MPa in this study. The coatings significantly decrease degradation rate of the original Mg alloy, indicating that the Mg alloy with calcium phosphate coating is a promising degradable bone material.

  2. Accidental Bowel Leakage

    MedlinePlus

    ... Women with a bowel control problem may leak gas or liquid or solid stool. Other symptoms may include the ... which can lead to leakage of solid or liquid stool (feces) or gas. Anoscopy: An exam of the anus using an ...

  3. High-precision determination of 18O/16O ratios of silver phosphate by EA-pyrolysis-IRMS continuous flow technique.

    PubMed

    Lécuyer, Christophe; Fourel, François; Martineau, François; Amiot, Romain; Bernard, Aurélien; Daux, Valérie; Escarguel, Gilles; Morrison, John

    2007-01-01

    A high-precision, and rapid on-line method for oxygen isotope analysis of silver phosphate is presented. The technique uses high-temperature elemental analyzer (EA)-pyrolysis interfaced in continuous flow (CF) mode to an isotopic ratio mass spectrometer (IRMS). Calibration curves were generated by synthesizing silver phosphate with a 13 per thousand spread in delta(18)O values. Calibration materials were obtained by reacting dissolved potassium dihydrogen phosphate (KH(2)PO(4)) with water samples of various oxygen isotope compositions at 373 K. Validity of the method was tested by comparing the on-line results with those obtained by classical off-line sample preparation and dual inlet isotope measurement. In addition, silver phosphate precipitates were prepared from a collection of biogenic apatites with known delta(18)O values ranging from 12.8 to 29.9 per thousand (V-SMOW). Reproducibility of +/- 0.2 per thousand was obtained by the EA-Py-CF-IRMS method for sample sizes in the range 400-500 microg. Both natural and synthetic samples are remarkably well correlated with conventional (18)O/(16)O determinations. Silver phosphate is a very stable material and easy to degas and, thus, could be considered as a good candidate to become a reference material for the determination of (18)O/(16)O ratios of phosphate by high-temperature pyrolysis. Copyright 2006 John Wiley & Sons, Ltd.

  4. Stimulation of colonic motility by oral PEG electrolyte bowel preparation assessed by MRI: comparison of split vs single dose

    PubMed Central

    Marciani, L; Garsed, K C; Hoad, C L; Fields, A; Fordham, I; Pritchard, S E; Placidi, E; Murray, K; Chaddock, G; Costigan, C; Lam, C; Jalanka-Tuovinen, J; De Vos, W M; Gowland, P A; Spiller, R C

    2014-01-01

    Background Most methods of assessing colonic motility are poorly acceptable to patients. Magnetic resonance imaging (MRI) can monitor gastrointestinal motility and fluid distributions. We predicted that a dose of oral polyethylene glycol (PEG) and electrolyte solution would increase ileo-colonic inflow and stimulate colonic motility. We aimed to investigate the colonic response to distension by oral PEG electrolyte in healthy volunteers (HVs) and to evaluate the effect of single 2 L vs split (2 × 1 L) dosing. Methods Twelve HVs received a split dose (1 L the evening before and 1 L on the study day) and another 12 HVs a single dose (2 L on the main study day) of PEG electrolyte. They underwent MRI scans, completed symptom questionnaires, and provided stool samples. Outcomes included small bowel water content, ascending colon motility index, and regional colonic volumes. Key Results Small bowel water content increased fourfold from baseline after ingesting both split (p = 0.0010) and single dose (p = 0.0005). The total colonic volume increase from baseline was smaller for the split dose at 35 ± 8% than for the single dose at 102 ± 27%, p = 0.0332. The ascending colon motility index after treatment was twofold higher for the single dose group (p = 0.0103). Conclusions & Inferences Ingestion of 1 and 2 L PEG electrolyte solution caused a rapid increase in the small bowel and colonic volumes and a robust rise in colonic motility. The increase in both volumes and motility was dose dependent. Such a challenge, being well-tolerated, could be a useful way of assessing colonic motility in future studies. PMID:25060551

  5. Irritable bowel syndrome--the main recommendations.

    PubMed

    Andresen, Viola; Keller, Jutta; Pehl, Christian; Schemann, Michael; Preiss, Jan; Layer, Peter

    2011-11-01

    Irritable bowel syndrome is characterized by chronic abdominal symptoms and irregular bowel movements without any cause than can be revealed by routine diagnostic assessment. In recent years, its pathophysiology has come to be much better understood, and new therapeutic approaches have been developed. These advances were taken into consideration and assessed for their relevance to clinical practice in the framework of a new interdisciplinary S3 guideline. A systematic search of the literature retrieved a total 5573 articles, from which 243 were selected on the basis of criteria relating to their form and content, individually assessed, and summarized in evidence tables. The recommendations formulated in this way were discussed in a Delphi procedure and a consensus conference, then accordingly modified and finalized. Variable symptom constellations are caused by disturbances of gastrointestinal regulation at multiple levels. The diagnosis of irritable bowel syndrome requires both chronic bowel symptoms that interfere with everyday life and the exclusion of relevant differential diagnoses. Its treatment is based on general therapeutic principles, dietary recommendations, psychological components, and symptomatic medication. Bulking agents, laxatives, spasmolytics, loperamide, and probiotic agents are recommended (with variable recommendation strengths), as are--for selected patients--antidepressants, 5-HT4 agonists, 5-HT3 antagonists, and topical antibiotics. The first German S3 guideline on irritable bowel syndrome translates up-to-date scientific knowledge as represented in current publications into concrete recommendations for diagnosis and treatment in clinical practice. In the future, it is likely that further causative pathophysiological mechanisms will be discovered; this should lead, in turn, to the development of new, causally directed treatments, which will supplement or replace the traditional, purely symptomatic treatments that are still in use today.

  6. Determination of phosphate concentration and pH in artificial tear drops.

    PubMed

    de Frutos-Lezaun, M; Martínez-Soroa, I; Ostra Beldarrain, M; Egia Zurutuza, A; Irastorza Larburu, M B; Fernandez Iriarte, A; Bachiller Cacho, M P

    2016-08-01

    To determine phosphate concentration and pH in artificial tear eye drops commercially available in Spain. A total of 71 examples of artificial tear preparations were identified in a search of Vademecum 2014 and the Spanish Medicines Agency website. In the 24 artificial tear products containing phosphates, quantification of these was performed by ultraviolet molecular absorption spectrophotometry, and the determination of pH was performed using scan image analysis algorithms of pH strips. Of the 71 artificial tears tested, 24 contained phosphate among their excipients in the data sheet, three of which had a concentration level below detection limit (<0.1mM). The mean phosphate concentration was 17.91±23.87mM. The artificial tear sample containing a higher concentration was Colircusi Humectante (87.1mM). Lubricants based on hypromellose showed the highest phosphate concentration (41.59±32.1mM), showing statistically significant differences compared to povidone (P=.0196) and hyaluronate (P=.0067). Statistically significant differences were found between products containing preservatives (32.39±20.91mM), and preservative free ones (8.49±11.98mM) (P=.0498). However, no difference was found between multidose (20.21±26.91mM) and unidose (9.31±14.39mM) samples, or between brand name (15.44±23.3mM) and generic eye drops (20.81mM). The mean pH was 6.93±0.26 (6.2-7.22). No statistical correlation was detected between phosphate concentration and pH (Spearman's Rho -0.1089 and P=.6125). A total of 24 (33.8%) of the 71 artificial tears contained phosphate. We believe identifying the phosphate concentration of artificial tears is useful information in order to avoid complications in high-risk patients. Copyright © 2016. Published by Elsevier España, S.L.U.

  7. Fecal Microbiota Transplantation in Inflammatory Bowel Disease: A Primer for Internists.

    PubMed

    Syal, Gaurav; Kashani, Amir; Shih, David Q

    2018-03-29

    Inflammatory bowel disease consists of disorders characterized by chronic idiopathic bowel inflammation. The concept of host-gut-microbiome interaction in the pathogenesis of various complex immune-mediated chronic diseases, including inflammatory bowel disease, has recently generated immense interest. Mounting evidence confirms alteration of intestinal microflora in patients with inflammatory bowel disease. Thus, restoration of normal gut microbiota has become a focus of basic and clinical research in recent years. Fecal microbiota transplantation is being explored as one such therapeutic strategy and has shown encouraging results in the management of patients with inflammatory bowel disease. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Solar radiation is inversely associated with inflammatory bowel disease admissions.

    PubMed

    Jaime, Francisca; Riutort, Maria C; Alvarez-Lobos, Manuel; Hoyos-Bachiloglu, Rodrigo; Camargo, Carlos A; Borzutzky, Arturo

    To explore the associations between latitude and solar radiation with inflammatory bowel disease admission rates in Chile, the country with the largest variation in solar radiation in the world. This is an ecological study, which included data on all hospital-admitted population for inflammatory bowel disease between 2001 and 2012, according to different latitudes and solar radiation exposures in Chile. The data were acquired from the national hospital discharge database from the Department of Health Statistics and Information of the Chilean Ministry of Health. Between 2001 and 2012 there were 12,869 admissions due to inflammatory bowel disease (69% ulcerative colitis, 31% Crohn's disease). Median age was 36 years (IQR: 25-51); 57% were female. The national inflammatory bowel disease admission rate was 6.52 (95% CI: 6.40-6.63) per 100,000 inhabitants with increasing rates over the 12-year period. In terms of latitude, the highest admission rates for pediatric ulcerative colitis and Crohn's disease, as well as adult ulcerative colitis, were observed in the southernmost region with lowest annual solar radiation. Linear regression analysis showed that regional solar radiation was inversely associated with inflammatory bowel disease admissions in Chile (β: -.44, p = .03). Regional solar radiation was inversely associated with inflammatory bowel disease admission rates in Chile; inflammatory bowel disease admissions were highest in the southernmost region with lowest solar radiation. Our results support the potential role of vitamin D deficiency on inflammatory bowel disease flares.

  9. Virtual Colonoscopy Screening With Ultra Low-Dose CT and Less-Stressful Bowel Preparation: A Computer Simulation Study

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Wang, Su; Li, Lihong; Fan, Yi; Lu, Hongbing; Liang, Zhengrong

    2008-10-01

    Computed tomography colonography (CTC) or CT-based virtual colonoscopy (VC) is an emerging tool for detection of colonic polyps. Compared to the conventional fiber-optic colonoscopy, VC has demonstrated the potential to become a mass screening modality in terms of safety, cost, and patient compliance. However, current CTC delivers excessive X-ray radiation to the patient during data acquisition. The radiation is a major concern for screening application of CTC. In this work, we performed a simulation study to demonstrate a possible ultra low-dose CT technique for VC. The ultra low-dose abdominal CT images were simulated by adding noise to the sinograms of the patient CTC images acquired with normal dose scans at 100 mA s levels. The simulated noisy sinogram or projection data were first processed by a Karhunen-Loeve domain penalized weighted least-squares (KL-PWLS) restoration method and then reconstructed by a filtered backprojection algorithm for the ultra low-dose CT images. The patient-specific virtual colon lumen was constructed and navigated by a VC system after electronic colon cleansing of the orally-tagged residue stool and fluid. By the KL-PWLS noise reduction, the colon lumen can successfully be constructed and the colonic polyp can be detected in an ultra low-dose level below 50 mA s. Polyp detection can be found more easily by the KL-PWLS noise reduction compared to the results using the conventional noise filters, such as Hanning filter. These promising results indicate the feasibility of an ultra low-dose CTC pipeline for colon screening with less-stressful bowel preparation by fecal tagging with oral contrast.

  10. How patients view probiotics: findings from a multicenter study of patients with inflammatory bowel disease and irritable bowel syndrome.

    PubMed

    Mercer, MaryBeth; Brinich, Margaret A; Geller, Gail; Harrison, Krista; Highland, Janelle; James, Katherine; Marshall, Patricia; McCormick, Jennifer B; Tilburt, Jon; Achkar, Jean-Paul; Farrell, Ruth M; Sharp, Richard R

    2012-02-01

    Patients with inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS) have access to a growing number of probiotic products marketed to improve digestive health. It is unclear how patients make decisions about probiotics and what role they expect their gastroenterologists to play as they consider using probiotics. Understanding patients' knowledge, attitudes and expectations of probiotics may help gastroenterologists engage patients in collaborative discussions about probiotics. Focus groups were conducted with patients with IBD and IBS at the Cleveland Clinic, Mayo Clinic, and Johns Hopkins University. Inductive analytic methods were used to identify common themes and draw interpretations from focus group narratives. One hundred thirty-six patients participated in 22 focus groups between March and August 2009. Patients viewed probiotics as an appealing alternative to pharmaceutical drugs and understood probiotics as a more "natural," low-risk therapeutic option. Many patients were hesitant to use them without consulting their gastroenterologists. Patients would weigh the risks and benefits of probiotics, their disease severity and satisfaction with current treatments when considering probiotic use. Patients are interested in probiotics but have many unanswered questions about their use. Our findings suggest that patients with IBD and IBS will look to gastroenterologists and other clinicians as trustworthy advisors regarding the utility of probiotics as an alternative or supplement to pharmaceutical drugs. Gastroenterologists and other clinicians who care for patients with these diseases should be prepared to discuss the potential benefits and risks of probiotics and assist patients in making informed decisions about their use.

  11. How Patients View Probiotics: Findings from a Multicenter Study of Patients with Inflammatory Bowel Disease and Irritable Bowel Syndrome

    PubMed Central

    Mercer, MaryBeth; Brinich, Margaret A.; Geller, Gail; Harrison, Krista; Highland, Janelle; James, Katherine; Marshall, Patricia; McCormick, Jennifer B.; Tilburt, Jon; Achkar, Jean-Paul; Farrell, Ruth M.; Sharp, Richard R.

    2011-01-01

    Background Patients with inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS) have access to a growing number of probiotic products marketed to improve digestive health. It is unclear how patients make decisions about probiotics and what role they expect their gastroenterologists to play as they consider using probiotics. Understanding patients’ knowledge, attitudes and expectations of probiotics may help gastroenterologists engage patients in collaborative discussions about probiotics. Study Focus groups were conducted with patients with IBD and IBS at the Cleveland Clinic, Mayo Clinic and Johns Hopkins University. Inductive analytic methods were utilized to identify common themes and draw interpretations from focus group narratives. Results One hundred thirty-six patients participated in 22 focus groups between March and August 2009. Patients viewed probiotics as an appealing alternative to pharmaceutical drugs and understood probiotics as a more “natural,” low-risk therapeutic option. Many patients were hesitant to use them without consulting their gastroenterologists. Patients would weigh the risks and benefits of probiotics, their disease severity and satisfaction with current treatments when considering probiotic use. Conclusions Patients are interested in probiotics but have many unanswered questions about their use. Our findings suggest that patients with IBD and IBS will look to gastroenterologists and other clinicians as trustworthy advisors regarding the utility of probiotics as an alternative or supplement to pharmaceutical drugs. Gastroenterologists and other clinicians who care for patients with these diseases should be prepared to discuss the potential benefits and risks of probiotics and assist patients in making informed decisions about their use. PMID:21716123

  12. Microwave-Assisted Hydrothermal Rapid Synthesis of Calcium Phosphates: Structural Control and Application in Protein Adsorption

    PubMed Central

    Cai, Zhu-Yun; Peng, Fan; Zi, Yun-Peng; Chen, Feng; Qian, Qi-Rong

    2015-01-01

    Synthetic calcium phosphate (CaP)-based materials have attracted much attention in the biomedical field. In this study, we have investigated the effect of pH values on CaP nanostructures prepared using a microwave-assisted hydrothermal method. The hierarchical nanosheet-assembled hydroxyapatite (HAP) nanostructure was prepared under weak acidic conditions (pH 5), while the HAP nanorod was prepared under neutral (pH 7) and weak alkali (pH 9) condition. However, when the pH value increases to 11, a mixed product of HAP nanorod and tri-calcium phosphate nanoparticle was obtained. The results indicated that the pH value of the initial reaction solution played an important role in the phase and structure of the CaP. Furthermore, the protein adsorption and release performance of the as-prepared CaP nanostructures were investigated by using hemoglobin (Hb) as a model protein. The sample that was prepared at pH = 11 and consisted of mixed morphologies of nanorods and nanoprisms showed a higher Hb protein adsorption capacity than the sample prepared at pH 5, which could be explained by its smaller size and dispersed structure. The results revealed the relatively high protein adsorption capacity of the as-prepared CaP nanostructures, which show promise for applications in various biomedical fields such as drug delivery and protein adsorption. PMID:28347064

  13. Microwave-Assisted Hydrothermal Rapid Synthesis of Calcium Phosphates: Structural Control and Application in Protein Adsorption.

    PubMed

    Cai, Zhu-Yun; Peng, Fan; Zi, Yun-Peng; Chen, Feng; Qian, Qi-Rong

    2015-07-31

    Synthetic calcium phosphate (CaP)-based materials have attracted much attention in the biomedical field. In this study, we have investigated the effect of pH values on CaP nanostructures prepared using a microwave-assisted hydrothermal method. The hierarchical nanosheet-assembled hydroxyapatite (HAP) nanostructure was prepared under weak acidic conditions (pH 5), while the HAP nanorod was prepared under neutral (pH 7) and weak alkali (pH 9) condition. However, when the pH value increases to 11, a mixed product of HAP nanorod and tri-calcium phosphate nanoparticle was obtained. The results indicated that the pH value of the initial reaction solution played an important role in the phase and structure of the CaP. Furthermore, the protein adsorption and release performance of the as-prepared CaP nanostructures were investigated by using hemoglobin (Hb) as a model protein. The sample that was prepared at pH = 11 and consisted of mixed morphologies of nanorods and nanoprisms showed a higher Hb protein adsorption capacity than the sample prepared at pH 5, which could be explained by its smaller size and dispersed structure. The results revealed the relatively high protein adsorption capacity of the as-prepared CaP nanostructures, which show promise for applications in various biomedical fields such as drug delivery and protein adsorption.

  14. Small bowel cleansing for capsule endoscopy in paediatric patients: a prospective randomized single-blind study.

    PubMed

    Oliva, Salvatore; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Ferrari, Federica; Civitelli, Fortunata; Pagliaro, Giuseppe; Di Nardo, Giovanni

    2014-01-01

    Small bowel cleansing by capsule endoscopy has never been addressed in children. Randomized controlled trial to evaluate the effect of five bowel preparation regimens on the mucosal visibility surface (as percentage of visualized surface area). Group A: a clear liquid diet for 12 h on the day before; Group B: high volume polyethylene glycol (50 mL/kg, up to 2Lt/die); Group C: low volume polyethylene glycol (25 mL/kg up to 1Lt/die); Group D: 20 mL (376 mg) of oral simethicone; Group E: 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone. Overall, 198 patients (53% male, median age 13 years) were enrolled. Preparation regimen visualization scores were 14.1 ± 4.2, 18.9 ± 5.1, 17.8 ± 5.5, 14.9 ± 4.8 and 20.9 ± 4.6 in groups A, B, C, D and E, respectively (P < 0.01). Positive findings were found in 172 cases (87%), but no significant differences were observed in the diagnostic yield and tolerability. Interobserver agreement, k = 0.89 (95% CI 0.83 ± 0.71). This is the first report in children that supports the use of 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone as the preparation of choice for capsule endoscopy. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  15. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation

    PubMed Central

    Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-01-01

    Background In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective Objective of this study was to assess the function of an automated text messaging (short message service, SMS)–supported colonoscopy preparation starting 4 days before colonoscopy appointment. Methods After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging–provided information assessed by a questionnaire. Results Web-based SMS text messaging–supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging–based information was high. Conclusions Using SMS for colonoscopy preparation with 4 days’ guidance including dietary recommendation is a new approach

  16. ACG Clinical Guideline: Diagnosis and Management of Small Bowel Bleeding.

    PubMed

    Gerson, Lauren B; Fidler, Jeff L; Cave, David R; Leighton, Jonathan A

    2015-09-01

    Bleeding from the small intestine remains a relatively uncommon event, accounting for ~5-10% of all patients presenting with gastrointestinal (GI) bleeding. Given advances in small bowel imaging with video capsule endoscopy (VCE), deep enteroscopy, and radiographic imaging, the cause of bleeding in the small bowel can now be identified in most patients. The term small bowel bleeding is therefore proposed as a replacement for the previous classification of obscure GI bleeding (OGIB). We recommend that the term OGIB should be reserved for patients in whom a source of bleeding cannot be identified anywhere in the GI tract. A source of small bowel bleeding should be considered in patients with GI bleeding after performance of a normal upper and lower endoscopic examination. Second-look examinations using upper endoscopy, push enteroscopy, and/or colonoscopy can be performed if indicated before small bowel evaluation. VCE should be considered a first-line procedure for small bowel investigation. Any method of deep enteroscopy can be used when endoscopic evaluation and therapy are required. VCE should be performed before deep enteroscopy if there is no contraindication. Computed tomographic enterography should be performed in patients with suspected obstruction before VCE or after negative VCE examinations. When there is acute overt hemorrhage in the unstable patient, angiography should be performed emergently. In patients with occult hemorrhage or stable patients with active overt bleeding, multiphasic computed tomography should be performed after VCE or CTE to identify the source of bleeding and to guide further management. If a source of bleeding is identified in the small bowel that is associated with significant ongoing anemia and/or active bleeding, the patient should be managed with endoscopic therapy. Conservative management is recommended for patients without a source found after small bowel investigation, whereas repeat diagnostic investigations are recommended

  17. Proctalgia fugax in patients with the irritable bowel, peptic ulcer, or inflammatory bowel disease.

    PubMed

    Thompson, W G

    1984-06-01

    One hundred forty-eight patients with gastrointestinal disease, 50 patients with the irritable bowel syndrome (IBS) and 49 each with peptic ulcer and inflammatory bowel disease, were interviewed to determine if they had proctalgia fugax (PF) and if the symptom was associated with the IBS. One-third of the patients had PF. It occurred in 51% of females and 12% of males (p less than 0.001). When corrected for sex, PF was no more prevalent in IBS than in peptic ulcer or inflammatory bowel disease. Only two of six previously described IBS symptoms were more prevalent in the PF patients. Attacks occurred in the day in 94%, and one-third of sufferers related them to defecation. The pain was localized in the anus in 90%, occurred less than five times a year in 51%, and lasted less than 1 min in 57%. In most, activity was not interrupted by this pain and only 20% had ever reported it to a physician. PF is very common among patients with abdominal symptoms, but is not related to the IBS. Since it is infrequent, benign, and transient, PF is usually not mentioned to the physician.

  18. Sugarcane bagasse derivative-based superabsorbent containing phosphate rock with water-fertilizer integration.

    PubMed

    Zhong, Kang; Zheng, Xi-Liang; Mao, Xiao-Yun; Lin, Zuan-Tao; Jiang, Gang-Biao

    2012-10-01

    To improve the water-fertilizer utilization ratio and mitigate the environmental contamination, an eco-friendly superabsorbent polymer (SPA), modified sugarcane bagasse/poly (acrylic acid) embedding phosphate rock (MSB/PAA/PHR), was prepared. Ammonia, phosphate rock (PHR) and KOH were admixed in the presence of acrylic acid to provide nitrogen (N), phosphorus (P) and potassium (K) nutrients, respectively. Impacts on water absorption capacity of the superabsorbent polymer (SAP) were investigated. The maximum swelling capacity in distilled water and 0.9 wt.% (weight percent) NaCl solution reached 414 gg(-1) and 55 gg(-1) (water/prepared SAP), respectively. The available NPK contents of the combination system were 15.13 mgg(-1), 6.93 mgg(-1) and 52.05 mgg(-1), respectively. Moreover, the release behaviors of NPK in the MSB/PAA/PHR were also studied. The results showed that the MSB/PAA/PHR has outstanding sustained-release plant nutrients property. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Bioerosion by euendoliths decreases in phosphate-enriched skeletons of living corals

    NASA Astrophysics Data System (ADS)

    Godinot, C.; Tribollet, A.; Grover, R.; Ferrier-Pagès, C.

    2012-03-01

    While the role of microboring organisms, or euendoliths, is relatively well known in dead coral skeletons, their function in live corals remains poorly understood. They are suggested to behave like ectosymbionts or parasites, impacting their host health. However, the species composition of microboring communities, their abundance and dynamics in live corals under various environmental conditions have never been explored. Here, the effect of phosphate enrichment on boring microorganisms in live corals was tested for the first time. S. pistillata nubbins were exposed to 3 different treatments (phosphate enrichments of 0, 0.5 and 2.5 μmol l-1) during 15 weeks. After 15 weeks of phosphate enrichment, petrographic thin sections were prepared for observation with light microscopy, and additional samples were examined with scanning electron microscopy (SEM). Euendoliths comprised mainly autotrophic Ostreobium sp. filaments. Rare filaments of heterotrophic fungi were also observed. Filaments were densely distributed in the central part of nubbins, and less abundant towards the apex. Unexpectedly, there was a visible reduction of filaments abundance in the most recently-calcified apical part of phosphate-enriched nubbins. The overall abundance of euendoliths significantly decreased, from 9.12 ± 1.09% of the skeletal surface area in unenriched corals, to 5.81 ± 0.77% and 5.27 ± 0.34% in 0.5 and 2.5 μmol l-1-phosphate enriched corals respectively. SEM observations confirmed this decrease. Recent studies have shown that phosphate enrichment increases coral skeletal growth and metabolic rates, while it decreases skeletal density and resilience to mechanical stress. We thus hypothesize that increased skeletal growth in the presence of phosphate enrichment occurred too fast for an effective euendolith colonization. They could not keep up with coral growth, so they became diluted in the apex areas as nubbins grew with phosphate enrichment. The possible advantages and

  20. Phosphate removal and hemodialysis conditions.

    PubMed

    Pohlmeier, R; Vienken, J

    2001-02-01

    Hyperphosphatemia is frequently found in hemodialysis patients, and the association with an increased risk of mortality has been demonstrated. Other authors have linked hyperphosphatemia to increased cardiovascular mortality. The normalization of phosphate plasma levels is therefore an important goal in the treatment of end-stage renal disease patients. Absorption of phosphate from the food exceeds the elimination through a hemodialysis treatment, and this leads to a chronic phosphate load for the majority of hemodialysis patients. This imbalance should be improved by either a reduction of phosphate absorption or an increased removal of phosphate. A reduction of phosphate absorption can be achieved by reducing the amount of phosphate in the diet or by the administration of phosphate binders. Unfortunately, these measures imply practical difficulties, for example, a lack of patient compliance or other side effects. When considering modifications of the hemodialysis treatment, an essential understanding of the kinetics of dialytic phosphate removal is mandatory. Phosphate is unevenly distributed in different compartments of the body. Only a very small amount of phosphate is present in the easily accessible plasma compartment. The major part of phosphate removed during hemodialysis originates from the cytoplasm of cells. A transfer from intracellular space to the plasma and further from the plasma to the dialysate is necessary. However, if we consider improvement to phosphate removal by dialysis procedures, full dialyzer clearance is effective in only the initial phase of the dialysis treatment. After this initial phase, the transfer rate for phosphate from the intracellular space to the plasma becomes the rate-limiting step for phosphate transport. Attempts to improve this transfer rate have recently been investigated by acidosis correction, but turned out not to be consistently successful. Furthermore, modifications of the treatment schedule have been described in

  1. Pharmacotherapy for Irritable Bowel Syndrome

    PubMed Central

    Camilleri, Michael

    2017-01-01

    Irritable bowel syndrome (IBS) is a disorder of the brain-gut axis; the pathophysiological mechanisms include altered colonic motility, bile acid metabolism, neurohormonal regulation, immune dysfunction, alterations in the epithelial barrier and secretory properties of the gut. This article reviews the mechanisms, efficacy, and safety of current pharmacotherapy, and medications that are in phase III trials for the treatment of IBS. There remains a significant unmet need for effective treatments—particularly for the pain component of IBS—although the introduction of drugs directed at secretion, motility and a non-absorbable antibiotic provide options for the bowel dysfunction in IBS. PMID:29077050

  2. Software-assisted small bowel motility analysis using free-breathing MRI: feasibility study.

    PubMed

    Bickelhaupt, Sebastian; Froehlich, Johannes M; Cattin, Roger; Raible, Stephan; Bouquet, Hanspeter; Bill, Urs; Patak, Michael A

    2014-01-01

    To validate a software prototype allowing for small bowel motility analysis in free breathing by comparing it to manual measurements. In all, 25 patients (15 male, 10 female; mean age 39 years) were included in this Institutional Review Board-approved, retrospective study. Magnetic resonance imaging (MRI) was performed on a 1.5T system after standardized preparation acquiring motility sequences in free breathing over 69-84 seconds. Small bowel motility was analyzed manually and with the software. Functional parameters, measurement time, and reproducibility were compared using the coefficient of variance and paired Student's t-test. Correlation was analyzed using Pearson's correlation coefficient and linear regression. The 25 segments were analyzed twice both by hand and using the software with automatic breathing correction. All assessed parameters significantly correlated between the methods (P < 0.01), but the scattering of repeated measurements was significantly (P < 0.01) lower using the software (3.90%, standard deviation [SD] ± 5.69) than manual examinations (9.77%, SD ± 11.08). The time needed was significantly less (P < 0.001) with the software (4.52 minutes, SD ± 1.58) compared to manual measurement, lasting 17.48 minutes for manual (SD ± 1.75 minutes). The use of the software proves reliable and faster small bowel motility measurements in free-breathing MRI compared to manual analyses. The new technique allows for analyses of prolonged sequences acquired in free breathing, improving the informative value of the examinations by amplifying the evaluable data. Copyright © 2013 Wiley Periodicals, Inc.

  3. Phosphate-a poison for humans?

    PubMed

    Komaba, Hirotaka; Fukagawa, Masafumi

    2016-10-01

    Maintenance of phosphate balance is essential for life, and mammals have developed a sophisticated system to regulate phosphate homeostasis over the course of evolution. However, due to the dependence of phosphate elimination on the kidney, humans with decreased kidney function are likely to be in a positive phosphate balance. Phosphate excess has been well recognized as a critical factor in the pathogenesis of mineral and bone disorders associated with chronic kidney disease, but recent investigations have also uncovered toxic effects of phosphate on the cardiovascular system and the aging process. Compelling evidence also suggests that increased fibroblastic growth factor 23 and parathyroid hormone levels in response to a positive phosphate balance contribute to adverse clinical outcomes. These insights support the current practice of managing serum phosphate in patients with advanced chronic kidney disease, although definitive evidence of these effects is lacking. Given the potential toxicity of excess phosphate, the general population may also be viewed as a target for phosphate management. However, the widespread implementation of dietary phosphate intervention in the general population may not be warranted due to the limited impact of increased phosphate intake on mineral metabolism and clinical outcomes. Nonetheless, the increasing incidence of kidney disease or injury in our aging society emphasizes the potential importance of this issue. Further work is needed to more completely characterize phosphate toxicity and to establish the optimal therapeutic strategy for managing phosphate in patients with chronic kidney disease and in the general population. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  4. Ammonium, Nitrate, and Phosphate Sorption to and Solute Leaching from Biochars Prepared from Corn Stover ( L.) and Oak Wood ( spp.).

    PubMed

    Hollister, C Colin; Bisogni, James J; Lehmann, Johannes

    2013-01-01

    Biochar (BC) was evaluated for nitrogen (N) and phosphorus (P) removal from aqueous solution to quantify its nutrient pollution mitigation potential in agroecosystems. Sorption isotherms were prepared for solutions of ammonium (NH), nitrate (NO), and phosphate (PO-P) using BC of corn ( L.) and oak ( spp.) feedstock, each pyrolyzed at 350 and 550°C highest treatment temperature (HTT). Sorption experiments were performed on original BC as well as on BC that went through a water extraction pretreatment (denoted WX-BC). Ammonium sorption was observed for WX-Oak-BC and WX-Corn-BC, and Freundlich model linearization showed that a 200°C increase in HTT resulted in a 55% decrease in * values for WX-Oak-BC and a 69% decrease in * for WX-Corn-BC. Nitrate sorption was not observed for any BC. Removing metals by water extraction from WX-Oak-350 and WX-Oak-550 resulted in a 25 to 100% decrease in phosphate removal efficiency relative to original Oak-350 and Oak-550, respectively. No PO-P sorption was observed using any Corn-BC. Calcium (Ca) leached from BC produced at 550°C was 63 and 104% higher than from BC produced at 350°C for corn and oak, respectively. Leaching of P was two orders of magnitude lower in WX-Oak-BC than in WX-Corn-BC, concurrent with similar difference in magnesium (Mg). Nitrate and NH leaching from consecutive water extractions of all tested BCs was mostly below detection limits. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  5. Trace element and isotope studies in oxide/phosphate/silicate inclusions of iron meteorites

    NASA Technical Reports Server (NTRS)

    Olsen, Edward J.

    1996-01-01

    Under the above grant research was funded in the following areas: 1. Pallasites: Rare earth element measurements in phosphates to determine if all pallasites fit into only two trace element groups. This work has been completed. 2. HIAB irons: To complete work on the only known silicate inclusion in a IIIAB iron meteorite. This work has been completed. 3. IIIAB irons: To continue the search for Cr-53 excesses in IIIAB iron meteorite phosphates. A part of this work has been completed 4. IIIAB irons: To complete the identification of the phosphate minerals in IIIAB iron meteorites and try to determine the phase relations and chemical history of trace element distributions during the core formation process. Work on this has been largely completed and preliminary results have been reported. The final work is being assessed prior to preparation of a manuscript for publication. 5. IIE irons: To complete work on the unique silicate assemblage in the IIE iron meteorite. Work on this was completed and a paper published. 6. Ungrouped irons: A partially devitrified silicate glass inclusion has been found in the ungrouped iron meteorite. Preliminary work on this has been reported. All the work on this has been now completed and a manuscript has been prepared and submitted for publication.

  6. An Investigation of Fiber Reinforced Chemically Bonded Phosphate Ceramic Composites at Room Temperature.

    PubMed

    Ding, Zhu; Li, Yu-Yu; Lu, Can; Liu, Jian

    2018-05-21

    In this study, chemically bonded phosphate ceramic (CBPC) fiber reinforced composites were made at indoor temperatures. The mechanical properties and microstructure of the CBPC composites were studied. The CBPC matrix of aluminum phosphate binder, metakaolin, and magnesia with different Si/P ratios was prepared. The results show that when the Si/P ratio was 1.2, and magnesia content in the CBPC was 15%, CBPC reached its maximum flexural strength. The fiber reinforced CBPC composites were prepared by mixing short polyvinyl alcohol (PVA) fibers or unidirectional continuous carbon fiber sheets. Flexural strength and dynamic mechanical properties of the composites were determined, and the microstructures of specimens were analyzed by scanning electron micrography, X-ray diffraction, and micro X-ray computed tomography. The flexural performance of continuous carbon fiber reinforced CBPC composites was better than that of PVA fiber composites. The elastic modulus, loss modulus, and loss factor of the fiber composites were measured through dynamic mechanical analysis. The results showed that fiber reinforced CBPC composites are an inorganic polymer viscoelastic material with excellent damping properties. The reaction of magnesia and phosphate in the matrix of CBPC formed a different mineral, newberyite, which was beneficial to the development of the CBPC.

  7. Silver-Doped Calcium Phosphate Bone Cements with Antibacterial Properties

    PubMed Central

    Rau, J. V.; Fosca, M.; Graziani, V.; Egorov, A. A.; Zobkov, Yu. V.; Fedotov, A. Yu.; Ortenzi, M.; Caminiti, R.; Baranchikov, A. E.; Komlev, V. S.

    2016-01-01

    Calcium phosphate bone cements (CPCs) with antibacterial properties are demanded for clinical applications. In this study, we demonstrated the use of a relatively simple processing route based on preparation of silver-doped CPCs (CPCs-Ag) through the preparation of solid dispersed active powder phase. Real-time monitoring of structural transformations and kinetics of several CPCs-Ag formulations (Ag = 0 wt %, 0.6 wt % and 1.0 wt %) was performed by the Energy Dispersive X-ray Diffraction technique. The partial conversion of β-tricalcium phosphate (TCP) phase into the dicalcium phosphate dihydrate (DCPD) took place in all the investigated cement systems. In the pristine cement powders, Ag in its metallic form was found, whereas for CPC-Ag 0.6 wt % and CPC-Ag 1.0 wt % cements, CaAg(PO3)3 was detected and Ag (met.) was no longer present. The CPC-Ag 0 wt % cement exhibited a compressive strength of 6.5 ± 1.0 MPa, whereas for the doped cements (CPC-Ag 0.6 wt % and CPC-Ag 1.0 wt %) the reduced values of the compressive strength 4.0 ± 1.0 and 1.5 ± 1.0 MPa, respectively, were detected. Silver-ion release from CPC-Ag 0.6 wt % and CPC-Ag 1.0 wt % cements, measured by the Atomic Emission Spectroscopy, corresponds to the average values of 25 µg/L and 43 µg/L, respectively, rising a plateau after 15 days. The results of the antibacterial test proved the inhibitory effect towards pathogenic Escherichia coli for both CPC-Ag 0.6 wt % and CPC-Ag 1.0 wt % cements, better performances being observed for the cement with a higher Ag-content. PMID:27096874

  8. Irritable bowel syndrome

    PubMed Central

    Enck, Paul; Aziz, Qasim; Barbara, Giovanni; Farmer, Adam D.; Fukudo, Shin; Mayer, Emeran A.; Niesler, Beate; Quigley, Eamonn M. M.; Rajilić-Stojanović, Mirjana; Schemann, Michael; Schwille-Kiuntke, Juliane; Simren, Magnus; Zipfel, Stephan; Spiller, Robin C.

    2016-01-01

    Irritable bowel syndrome (IBS) is a functional gastrointestinal disease with a high population prevalence. The disorder can be debilitating in some patients, whereas others may have mild or moderate symptoms. The most important single risk factors are female sex, younger age and preceding gastrointestinal infections. Clinical symptoms of IBS include abdominal pain or discomfort, stool irregularities and bloating, as well as other somatic, visceral and psychiatric comorbidities. Currently, the diagnosis of IBS is based on symptoms and the exclusion of other organic diseases, and therapy includes drug treatment of the predominant symptoms, nutrition and psychotherapy. Although the underlying pathogenesis is far from understood, aetiological factors include increased epithelial hyperpermeability, dysbiosis, inflammation, visceral hypersensitivity, epigenetics and genetics, and altered brain–gut interactions. IBS considerably affects quality of life and imposes a profound burden on patients, physicians and the health-care system. The past decade has seen remarkable progress in our understanding of functional bowel disorders such as IBS that will be summarized in this Primer. PMID:27159638

  9. Head or tail: the orientation of the small bowel capsule endoscope movement in the small bowel.

    PubMed

    Kopylov, Uri; Papageorgiou, Neofytos P; Nadler, Moshe; Eliakim, Rami; Ben-Horin, Shomron

    2012-03-01

    The diagnostic accuracy of capsule endoscopy has been suggested to be influenced by the direction of the passage in the intestine. It is currently unknown if a head-first or a tail-first orientation are equally common during the descent through the small bowel. The aim of the study was to identify the orientation of the capsule along the migration through the small bowel. Thirty capsule endoscopies were reviewed by an experienced observer. The direction of the passage through the pylorus and the ileoceccal valve was recorded for all the examinations. In addition, detailed review of the passage of the capsule in different segments of the small bowel was undertaken for all the capsules. The capsule was significantly more likely to pass the pylorus head-first compared to tail-first (25 and 5 out of 30, respectively, OR 5, 95% CI 65-94%, P < 0.001). In 28/30 studies, the capsule exited the ileoceccal valve head-first (OR-14, 95% CI 77-99%, P < 0.001). In an immersion experiment, uneven distribution of weight of the capsule body was demonstrated with the head part (camera tip) being lighter than the tail part. The capsule endoscope usually passes through the pylorus and subsequent segments of the small bowel head-first. This observation suggests that the intestinal peristaltic physiology drives symmetrical bodies with their light part first. The principle of intestinal orientation by weight distribution may bear implications for capsules' design in the future.

  10. Multifunctional phosphate-based inorganic-organic hybrid nanoparticles.

    PubMed

    Heck, Joachim G; Napp, Joanna; Simonato, Sara; Möllmer, Jens; Lange, Marcus; Reichardt, Holger M; Staudt, Reiner; Alves, Frauke; Feldmann, Claus

    2015-06-17

    Phosphate-based inorganic-organic hybrid nanoparticles (IOH-NPs) with the general composition [M](2+)[Rfunction(O)PO3](2-) (M = ZrO, Mg2O; R = functional organic group) show multipurpose and multifunctional properties. If [Rfunction(O)PO3](2-) is a fluorescent dye anion ([RdyeOPO3](2-)), the IOH-NPs show blue, green, red, and near-infrared fluorescence. This is shown for [ZrO](2+)[PUP](2-), [ZrO](2+)[MFP](2-), [ZrO](2+)[RRP](2-), and [ZrO](2+)[DUT](2-) (PUP = phenylumbelliferon phosphate, MFP = methylfluorescein phosphate, RRP = resorufin phosphate, DUT = Dyomics-647 uridine triphosphate). With pharmaceutical agents as functional anions ([RdrugOPO3](2-)), drug transport and release of anti-inflammatory ([ZrO](2+)[BMP](2-)) and antitumor agents ([ZrO](2+)[FdUMP](2-)) with an up to 80% load of active drug is possible (BMP = betamethason phosphate, FdUMP = 5'-fluoro-2'-deoxyuridine 5'-monophosphate). A combination of fluorescent dye and drug anions is possible as well and shown for [ZrO](2+)[BMP](2-)0.996[DUT](2-)0.004. Merging of functional anions, in general, results in [ZrO](2+)([RdrugOPO3]1-x[RdyeOPO3]x)(2-) nanoparticles and is highly relevant for theranostics. Amine-based functional anions in [MgO](2+)[RaminePO3](2-) IOH-NPs, finally, show CO2 sorption (up to 180 mg g(-1)) and can be used for CO2/N2 separation (selectivity up to α = 23). This includes aminomethyl phosphonate [AMP](2-), 1-aminoethyl phosphonate [1AEP](2-), 2-aminoethyl phosphonate [2AEP](2-), aminopropyl phosphonate [APP](2-), and aminobutyl phosphonate [ABP](2-). All [M](2+)[Rfunction(O)PO3](2-) IOH-NPs are prepared via noncomplex synthesis in water, which facilitates practical handling and which is optimal for biomedical application. In sum, all IOH-NPs have very similar chemical compositions but can address a variety of different functions, including fluorescence, drug delivery, and CO2 sorption.

  11. Synthesis of bis-Phosphate Iminoaltritol Enantiomers and Structural Characterization with Adenine Phosphoribosyltransferase.

    PubMed

    Harris, Lawrence D; Harijan, Rajesh K; Ducati, Rodrigo G; Evans, Gary B; Hirsch, Brett M; Schramm, Vern L

    2018-01-19

    Phosphoribosyl transferases (PRTs) are essential in nucleotide synthesis and salvage, amino acid, and vitamin synthesis. Transition state analysis of several PRTs has demonstrated ribocation-like transition states with a partial positive charge residing on the pentose ring. Core chemistry for synthesis of transition state analogues related to the 5-phospho-α-d-ribosyl 1-pyrophosphate (PRPP) reactant of these enzymes could be developed by stereospecific placement of bis-phosphate groups on an iminoaltritol ring. Cationic character is provided by the imino group and the bis-phosphates anchor both the 1- and 5-phosphate binding sites. We provide a facile synthetic path to these molecules. Cyclic-nitrone redox methodology was applied to the stereocontrolled synthesis of three stereoisomers of a selectively monoprotected diol relevant to the synthesis of transition-state analogue inhibitors. These polyhydroxylated pyrrolidine natural product analogues were bis-phosphorylated to generate analogues of the ribocationic form of 5-phosphoribosyl 1-phosphate. A safe, high yielding synthesis of the key intermediate represents a new route to these transition state mimics. An enantiomeric pair of iminoaltritol bis-phosphates (L-DIAB and D-DIAB) was prepared and shown to display inhibition of Plasmodium falciparum orotate phosphoribosyltransferase and Saccharomyces cerevisiae adenine phosphoribosyltransferase (ScAPRT). Crystallographic inhibitor binding analysis of L- and D-DIAB bound to the catalytic sites of ScAPRT demonstrates accommodation of both enantiomers by altered ring geometry and bis-phosphate catalytic site contacts.

  12. Hypothalamic digoxin, hemispheric chemical dominance, and inflammatory bowel disease.

    PubMed

    Kurup, Ravi Kumar; Kurup, Parameswara Achutha

    2003-09-01

    The isoprenoid pathway produces three key metabolites--endogenous digoxin, dolichol, and ubiquinone. It was considered pertinent to assess the pathway in inflammatory bowel disease (ulcerative colitis and regional ileitis). Since endogenous digoxin can regulate neurotransmitter transport, the pathway and the related cascade were also assessed in individuals with differing hemispheric dominance to find out the role of hemispheric dominance in its pathogenesis. All the patients with inflammatory bowel disease were right-handed/left hemispheric dominant by the dichotic listening test. The following parameters were measured in patients with inflammatory bowel disease and in individuals with differing hemispheric dominance: (1) plasma HMG CoA reductase, digoxin, dolichol, ubiquinone, and magnesium levels; (2) tryptophan/tyrosine catabolic patterns; (3) free-radical metabolism; (4) glycoconjugate metabolism; and (5) membrane composition and RBC membrane Na+-K+ ATPase activity. Statistical analysis was done by ANOVA. In patients with inflammatory bowel disease there was elevated digoxin synthesis, increased dolichol and glycoconjugate levels, and low ubiquinone and elevated free radical levels. There was also an increase in tryptophan catabolites and a reduction in tyrosine catabolites. There was an increase in cholesterol:phospholipid ratio and a reduction in glycoconjugate level of RBC membrane in these groups of patients. Inflammatory bowel disease is associated with an upregulated isoprenoid pathway and elevated digoxin secretion from the hypothalamus. This can contribute to immune activation, defective glycoprotein bowel antigen presentation, and autoimmunity and a schizophreniform psychosis important in its pathogenesis. The biochemical patterns obtained in inflammatory bowel disease is similar to those obtained in left-handed/right hemispheric dominant individuals by the dichotic listening test. But all the patients with peptic ulcer disease were right

  13. Lubiprostone decreases the small bowel transit time by capsule endoscopy: an exploratory, randomised, double-blind, placebo-controlled 3-way crossover study.

    PubMed

    Matsuura, Mizue; Inamori, Masahiko; Endo, Hiroki; Matsuura, Tetsuya; Kanoshima, Kenji; Inoh, Yumi; Fujita, Yuji; Umezawa, Shotaro; Fuyuki, Akiko; Uchiyama, Shiori; Higurashi, Takuma; Ohkubo, Hidenori; Sakai, Eiji; Iida, Hiroshi; Nonaka, Takashi; Futagami, Seiji; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi

    2014-01-01

    The aim of this study was to investigate the usefulness of lubiprostone for bowel preparation and as a propulsive agent in small bowel endoscopy. Six healthy male volunteers participated in this randomized, 3-way crossover study. The subjects received a 24 μg tablet of lubiprostone 60 minutes prior to the capsule ingestion for capsule endoscopy (CE) and a placebo tablet 30 minutes before the capsule ingestion (L-P regimen), a placebo tablet 60 minutes prior to CE and a 24 μg tablet of lubiprostone 30 minutes prior to CE (P-L regimen), or a placebo tablet 60 minutes prior to r CE and a placebo tablet again 30 minutes prior to CE (P-P regimen). The quality of the capsule endoscopic images and the amount of water in the small bowel were assessed on 5-point scale. The median SBTT was 178.5 (117-407) minutes in the P-P regimen, 122.5 (27-282) minutes in the L-P regimen, and 110.5 (11-331) minutes in the P-L regimen (P = 0.042). This study showed that the use of lubiprostone significantly decreased the SBTT. We also confirmed that lubiprostone was effective for inducing water secretion into the small bowel during CE.

  14. Novel catalase loaded nanocores for the treatment of inflammatory bowel diseases.

    PubMed

    Parihar, Arun K S; Srivastava, Shikha; Patel, Satish; Singh, Manju R; Singh, Deependra

    2017-08-01

    Inflammatory bowel disease (IBD) is an inflammatory disorder of the digestive tract reported to be primarily caused by oxidative stress. In this study, alginate encapsulated nanoceramic carriers were designed to deliver acid labile antioxidant enzyme catalase orally. Complete system was characterized for size, loading efficiency, in vitro antioxidant assay and in vitro release. The prepared nanoceramic system was found to be spherical with diameter of 925 ± 6.81 nm. The in vitro release data followed the Higuchi model in acidic buffer whereas in alkaline pH sustained and almost first order release of enzyme was observed up to 6 h.

  15. Using phosphate supplementation to reverse hypophosphatemia and phosphate depletion in neurological disease and disturbance.

    PubMed

    Håglin, Lena

    2016-06-01

    Hypophosphatemia (HP) with or without intracellular depletion of inorganic phosphate (Pi) and adenosine triphosphate has been associated with central and peripheral nervous system complications and can be observed in various diseases and conditions related to respiratory alkalosis, alcoholism (alcohol withdrawal), diabetic ketoacidosis, malnutrition, obesity, and parenteral and enteral nutrition. In addition, HP may explain serious muscular, neurological, and haematological disorders and may cause peripheral neuropathy with paresthesias and metabolic encephalopathy, resulting in confusion and seizures. The neuropathy may be improved quickly after proper phosphate replacement. Phosphate depletion has been corrected using potassium-phosphate infusion, a treatment that can restore consciousness. In severe ataxia and tetra paresis, complete recovery can occur after adequate replacement of phosphate. Patients with multiple risk factors, often with a chronic disease and severe HP that contribute to phosphate depletion, are at risk for neurologic alterations. To predict both risk and optimal phosphate replenishment requires assessing the nutritional status and risk for re-feeding hypophosphatemia. The strategy for correcting HP depends on the severity of the underlying disease and the goal for re-establishing a phosphate balance to limit the consequences of phosphate depletion.

  16. Rheumatological manifestations in inflammatory bowel disease

    PubMed Central

    Voulgari, Paraskevi V.

    2011-01-01

    Rheumatological manifestations in inflammatory bowel disease (IBD) are frequent and include peripheral arthritis, axial involvement and peripheral enthesitis. Secondary osteoporosis and hypertrophic osteoarthropathy may also occur. Complications of IBD (e.g. septic arthritis) must be distinguished from sterile inflammation. Adverse effects of corticosteroid treatment, such as osteonecrosis, may also affect joints. Axial involvement ranges from low back pain to true ankylosing spondylitis. Human leukocyte antigen B27 is associated with axial involvement of IBD. Peripheral arthritis has been classified into two types. Type I is a pauciarticular, asymmetric usually non destructive arthritis affecting large joints and is usually associated with active bowel disease. Type II is a polyarthritis affecting small joints and tends to run a course independent of the bowel disease. Treatment of joint symptoms in IBD include sulphasalazine, azathioprine, methotrexate and glucocorticoids. Anti-tumor necrosis factor antibodies are effective in treating resistant or complicated Crohn’s disease as well as peripheral arthritis and axial involvement. PMID:24713717

  17. Characteristics of neurogenic bowel in spinal cord injury and perceived quality of life.

    PubMed

    Pardee, Connie; Bricker, Diedre; Rundquist, Jeanine; MacRae, Christi; Tebben, Cherisse

    2012-01-01

    To investigate the association between characteristics of individuals with spinal cord injury and neurogenic bowel and their perceived quality of life. The study design is an exploratory, descriptive correlational design. To measure the variables of the study the Quality of Life Survey developed by Randell et al. (2001) was used to measure perceived quality of life related to bowel management. Individual bowel management preferences and subjective costs and benefits of the preferences were gathered through the Neurogenic Bowel Characteristics Survey. PARTICIPANTS/METHOD: Data were collected from a random half of the individuals who met the inclusion criteria from the patient database (n=1193). Two hundred and forty one surveys were analyzed for this study. More than half of the sample (n=134) provided their own bowel management consisting of digital stimulation, suppositories, and other aids; 8% (n=19) had a colostomy. Regardless of the bowel management program 54% (n=127) were satisfied with current methods. Although time reported to complete bowel programs ranged from 1 to 120 minutes, there was no difference in rating of satisfaction with time. There was a statistically significant difference between those satisfied and dissatisfied with current bowel management and quality of life; those satisfied demonstrated a higher quality of life on three subscales, work function (p= .021), bowel problems (p< .001), and social function (p< .001). Those dissatisfied with their bowel program perceived a lower quality of life and indicated problems of time (p= .001), pain or discomfort (p= .033), and poor results (p< .001). Research data provide the patient's perspective on bowel management characteristics, complications, satisfaction, and their perceived quality of life. Results of this research will be incorporated into bowel management education and possible modification of the current inpatient bowel management program. © 2012 Association of Rehabilitation Nurses.

  18. Biomedical and sensing applications of a multi-mode biodegradable phosphate-based optical fiber

    NASA Astrophysics Data System (ADS)

    Podrazky, Ondřej; Peterka, Pavel; Vytykáčová, SoÅa.; Proboštová, Jana; Kuneš, Martin; Lyutakov, Oleksiy; Ceci-Ginistrelli, Edoardo; Pugliese, Diego; Boetti, Nadia G.; Janner, Davide; Milanese, Daniel

    2018-02-01

    We report on the employment of a biodegradable phosphate-based optical fiber as a pH sensing probe in physiological environment. The phosphate-based optical fiber preform was fabricated by the rod-in-tube technique. The fiber biodegradability was first tested in-vitro and then its biodegradability and toxicity were tested in-vivo. Optical probes for pH sensing were prepared by the immobilization of a fluorescent dye on the fiber tip by a sol-gel method. The fluorescence response of the pH-sensor was measured as a ratio of the emission intensities at the excitation wavelengths of 405 and 450 nm.

  19. Small bowel resection - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100039.htm Small bowel resection - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The small intestine absorbs much of the liquid from foods. ...

  20. An experimental technique to repair cracked teeth using calcium phosphate, melted by a laser beam: an in vitro evaluation.

    PubMed

    Levy, G C; Koubi, G F

    1993-11-01

    Using a neodymium: yttrium-aluminum-garnet laser beam to seal vertical root fracture lines with tricalcium phosphate paste represents an alternative treatment for cracked teeth with noted clinical results. This article describes a study of the permeability of molten crystals of hydroxyapatite in the dentin of a cracked root after crack lines have been filled with a preparation of tricalcium phosphate melted by a neodymium: yttrium-aluminum-garnet laser beam. The morphology of the sealed cracks was analyzed under a scanning electron microscope that showed a deep fusion of tricalcium phosphate along crack lines.

  1. Biomediated continuous release phosphate fertilizer

    DOEpatents

    Goldstein, A.H.; Rogers, R.D.

    1999-06-15

    A composition is disclosed for providing phosphate fertilizer to the root zone of plants. The composition comprises a microorganism capable of producing and secreting a solubilization agent, a carbon source for providing raw material for the microorganism to convert into the solubilization agent, and rock phosphate ore for providing a source of insoluble phosphate that is solubilized by the solubilization agent and released as soluble phosphate. The composition is provided in a physical form, such as a granule, that retains the microorganism, carbon source, and rock phosphate ore, but permits water and soluble phosphate to diffuse into the soil. A method of using the composition for providing phosphate fertilizer to plants is also disclosed. 13 figs.

  2. Biomediated continuous release phosphate fertilizer

    DOEpatents

    Goldstein, Alan H.; Rogers, Robert D.

    1999-01-01

    A composition is disclosed for providing phosphate fertilizer to the root zone of plants. The composition comprises a microorganism capable of producing and secreting a solubilization agent, a carbon source for providing raw material for the microorganism to convert into the solubilization agent, and rock phosphate ore for providing a source of insoluble phosphate that is solubilized by the solubilization agent and released as soluble phosphate. The composition is provided in a physical form, such as a granule, that retains the microorganism, carbon source, and rock phosphate ore, but permits water and soluble phosphate to diffuse into the soil. A method of using the composition for providing phosphate fertilizer to plants is also disclosed.

  3. Effect of bowel cleansing on colonic transit in constipation due to slow transit or evacuation disorder.

    PubMed

    Sloots, C E J; Felt-Bersma, R J F

    2002-02-01

    Colon transit time measurement with radio-opaque markers is a method of studying the passage of luminal contents throughout the colon. Overall colonic transit time (CTT), as well as segmental transit times [right (RTT), left (LTT) and rectosigmoid (RSTT)], can be calculated. We hypothesize that CTT is influenced by faecal impaction when the rectum is emptied infrequently. The aim of this study is to investigate the effect of bowel cleansing on colonic transit time in patients with chronic constipation. In 25 women (age 41 years; range 20-65 years) with constipation according to Thompson criteria, CTT measurement was performed in an unprepared situation and repeated after cleansing with 4 L of Klean-Prepreg. Ten healthy female volunteers (age 41 years; range 27-57 years) were used as controls. In constipated patients, CTT decreased from a median 70 h (range 10-130 h) to 48 h (5-94 h) in the cleansed state (P < 0.001). A shortening of transit time was found in all three segments. In 10 patients with slow transit (ST) (CTT > 86 h), CTT decreased from 110 h (range 94-130) to 86 (38-94) (P < 0.001). Five of the 10 patients with ST before bowel cleansing had a CTT below 86 h after cleansing. In female controls, uncleansed CTT and RSTT shortened from 39 h (23 to 62) and 17 h (8-29) to 29 h (17-48) and 10 h (0-20) after bowel cleansing (P=0.058 and P=0.046). Colonic intraluminal contents have a substantial effect on colonic transit. In female controls, bowel cleansing shortened rectosigmoid transit. Women with constipation had faster transit in the cleansed state, however, the distribution of markers was not altered. Despite the effect of bowel cleansing on CTT, it seems unnecessary to prepare the bowel in clinical practice because the differentiation of patients between slow transit constipation and outlet obstruction is not changed. However, because in an infrequent defecation pattern, the influence of faecal impaction is considerable, CTT should be applied with care for

  4. Role of Phosphate Transport System Component PstB1 in Phosphate Internalization by Nostoc punctiforme

    PubMed Central

    Hudek, L.; Premachandra, D.; Webster, W. A. J.

    2016-01-01

    ABSTRACT In bacteria, limited phosphate availability promotes the synthesis of active uptake systems, such as the Pst phosphate transport system. To understand the mechanisms that facilitate phosphate accumulation in the cyanobacterium Nostoc punctiforme, phosphate transport systems were identified, revealing a redundancy of Pst phosphate uptake systems that exists across three distinct operons. Four separate PstB system components were identified. pstB1 was determined to be a suitable target for creating phenotypic mutations that could result in the accumulation of excessive levels of phosphate through its overexpression or in a reduction of the capacity to accumulate phosphate through its deletion. Using quantitative real-time PCR (qPCR), it was determined that pstB1 mRNA levels increased significantly over 64 h in cells cultured in 0 mM added phosphate and decreased significantly in cells exposed to high (12.8 mM) phosphate concentrations compared to the level in cells cultured under normal (0.8 mM) conditions. Possible compensation for the loss of PstB1 was observed when pstB2, pstB3, and pstB4 mRNA levels increased, particularly in cells starved of phosphate. The overexpression of pstB1 increased phosphate uptake by N. punctiforme and was shown to functionally complement the loss of PstB in E. coli PstB knockout (PstB−) mutants. The knockout of pstB1 in N. punctiforme did not have a significant effect on cellular phosphate accumulation or growth for the most part, which is attributed to the compensation for the loss of PstB1 by alterations in the pstB2, pstB3, and pstB4 mRNA levels. This study provides novel in vivo evidence that PstB1 plays a functional role in phosphate uptake in N. punctiforme. IMPORTANCE Cyanobacteria have been evolving over 3.5 billion years and have become highly adept at growing under limiting nutrient levels. Phosphate is crucial for the survival and prosperity of all organisms. In bacteria, limited phosphate availability promotes

  5. 21 CFR 184.1434 - Magnesium phosphate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Magnesium phosphate. 184.1434 Section 184.1434... Listing of Specific Substances Affirmed as GRAS § 184.1434 Magnesium phosphate. (a) Magnesium phosphate includes both magnesium phosphate, dibasic, and magnesium phosphate, tribasic. Magnesium phosphate, dibasic...

  6. 21 CFR 184.1434 - Magnesium phosphate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Magnesium phosphate. 184.1434 Section 184.1434... Listing of Specific Substances Affirmed as GRAS § 184.1434 Magnesium phosphate. (a) Magnesium phosphate includes both magnesium phosphate, dibasic, and magnesium phosphate, tribasic. Magnesium phosphate, dibasic...

  7. 21 CFR 184.1434 - Magnesium phosphate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Magnesium phosphate. 184.1434 Section 184.1434... Listing of Specific Substances Affirmed as GRAS § 184.1434 Magnesium phosphate. (a) Magnesium phosphate includes both magnesium phosphate, dibasic, and magnesium phosphate, tribasic. Magnesium phosphate, dibasic...

  8. Osteoblast adhesion on novel machinable calcium phosphate/lanthanum phosphate composites for orthopedic applications.

    PubMed

    Ergun, Celaletdin; Liu, Huinan; Webster, Thomas J

    2009-06-01

    Lanthanum phosphate (LaPO(4), LP) was combined with either hydroxyapatite (HA) or tricalcium phosphate (TCP) to form novel composites for orthopedic applications. In this study, these composites were prepared by wet chemistry synthesis and subsequent powder mixing. These HA/LP and TCP/LP composites were characterized in terms of phase stability and microstructure evolution during sintering using X-ray diffraction (XRD) and scanning electron microscopy (SEM). Their machinability was evaluated using a direct drilling test. For HA/LP composites, LP reacted with HA during sintering and formed a new phase, Ca(8)La(2)(PO(4))(6)O(2), as a reaction by-product. However, TCP/LP composites showed phase stability and the formation of a weak interface between TCP and LP machinability when sintered at 1100 degrees C, which is crucial for achieving desirable properties. Thus, these novel TCP/LP composites fulfilled the requirements for machinability, a key consideration for manufacturing orthopedic implants. Moreover, the biocompatibility of these novel LP composites was studied, for the first time, in this paper. In vitro cell culture tests demonstrated that the LP and its composites supported osteoblast (bone-forming cell) adhesion similar to natural bioceramics (such as HA and TCP). In conclusion, these novel LP composites should be further studied and developed for more effectively treating bone related diseases or injuries. 2008 Wiley Periodicals, Inc.

  9. Rehabilitative therapy of short bowel syndrome: experimental study and clinical trial.

    PubMed

    Li, N; Zhu, W; Guo, F; Ren, J; Li, Y; Wang, X; Li, J

    2000-08-01

    To investigate the effect of growth hormone on proliferative activity of the residual small intestinal mucosa after massive small intestinal resection and to evaluate the clinical efficacy of bowel rehabilitative therapy for short bowel syndrome. Small intestinal mucosa proliferative activity were compared in rats from control group (sham operation), short bowel group (80% small bowel resection) and growth hormone treatment group (80% small bowel resection + growth hormone 1 U x kg(-1) x d(-1) for 28 days) with the aid of histology image analysis, flow cytometric assay, immunohistochemistry analysis and RT-PCR assay. The nutritional status, D-xylose absorption and stool nitrogen output were observed in 9 consecutive parenteral nutrition dependent patients with short bowel syndrome after intestinal rehabilitative therapy (growth hormone 8 - 12 U x kg(-1) x d(-1) im + glutamine 0.6 g x kg(-1) x d(-1) iv + special diet) for 21 continuous days. Growth hormone administration significantly increased rat small intestinal mucosal villous height, mucosal thickness, proliferative index, and the expression of proliferating cell nuclear antigen and c-jun mRNA. Rehabilitative therapy increased the body weight, serum total protein and album in concentrations in patients. Their D-xylose absorption indices increased and fecal nitrogen losses decreased. Follow-up data showed that 6 of the 9 patients sustained on enteral nutrition. Growth hormone enhances the proliferative activity of the mucosal epithelium and bowel rehabilitative therapy may benefit the patients with short bowel syndrome.

  10. How do arbuscular mycorrhizal fungi handle phosphate? New insight into fine-tuning of phosphate metabolism.

    PubMed

    Ezawa, Tatsuhiro; Saito, Katsuharu

    2018-04-27

    Contents Summary I. Introduction II. Foraging for phosphate III. Fine-tuning of phosphate homeostasis IV. The frontiers: phosphate translocation and export V. Conclusions and outlook Acknowledgements References SUMMARY: Arbuscular mycorrhizal fungi form symbiotic associations with most land plants and deliver mineral nutrients, in particular phosphate, to the host. Therefore, understanding the mechanisms of phosphate acquisition and delivery in the fungi is critical for full appreciation of the mutualism in this association. Here, we provide updates on physical, chemical, and biological strategies of the fungi for phosphate acquisition, including interactions with phosphate-solubilizing bacteria, and those on the regulatory mechanisms of phosphate homeostasis based on resurveys of published genome sequences and a transcriptome with reference to the latest findings in a model fungus. For the mechanisms underlying phosphate translocation and export to the host, which are major research frontiers in this field, not only recent advances but also testable hypotheses are proposed. Lastly, we briefly discuss applicability of the latest tools to gene silencing in the fungi, which will be breakthrough techniques for comprehensive understanding of the molecular basis of fungal phosphate metabolism. © 2018 The Authors. New Phytologist © 2018 New Phytologist Trust.

  11. Addition of Lubiprostone to polyethylene glycol(PEG) enhances the quality & efficacy of colonoscopy preparation: a randomized, double-blind, placebo controlled trial.

    PubMed

    Banerjee, Rupa; Chaudhari, Hrushikesh; Shah, Nirish; Saravanan, Arjunan; Tandan, Manu; Reddy, D Nageshwar

    2016-10-13

    Adequate bowel preparation is an essential prerequisite for complete mucosal visualization during colonoscopy. Polyethylene glycol (PEG) solutions are commonly used. However the large volume of the solution is often poorly tolerated. Addition of Lubiprostone (LB) could improve the adequacy of standard PEG preparation & reduce requirement. The aims to assess adequacy of PEG preparation with addition of single dose LB (24mcg) vs placebo and efficacy of reduced dose PEG + LB compared with full dose PEG + LB. Single center prospective double blind randomized controlled trial. Part I: 442 patients for colonoscopy randomized to receive placebo (GrA) or single dose of LB (GrB) prior to PEG preparation. Quality of bowel preparation graded 0-9 according to Boston Bowel Preparation Scale (BBPS). BBPS-9: excellent and BBPS 0-4: repeat procedure. Part II: 146 patients randomized to receive LB + 1.5 L PEG (GrC; 75) or LB + 1 L PEG (GrD; 71). BBPS score compared with GrB (2 L PEG). Part I: 442 patients (221 GrA & 221 Gr B). LB resulted in significant improvement in total BBPS (7.44 + 0.14 vs. 6.36 + 0.16, p < 0.0001). 66.5 % Gr B vs 38 % Gr A had excellent prep; 42.5 % GrB vs 24 % GrA had adequate prep. Repeat procedure needed 9.5 % Gr B vs 16.7 % Gr A (P < 0.01). Part II: No difference in BBPS scores with lower doses (Gr C&D) compared to standard (GrB) (Mean BBPS 7.44 + 0.14 GrA,7.30 + 0.25 GrC;7.25 + 0.26 GrD;p >0.05). Single dose LB prior to PEG significantly enhanced bowel preparation compared to PEG alone. There was no significant difference in quality of preparation with lower doses of PEG when combined with LB. The study protocol was approved by institutional review board and the trial was registered on March 22, 2011 with clinicaltrials.gov ( NCT01324284 ).

  12. Daily bowel care program

    MedlinePlus

    ... a brain or spinal cord injury. People with multiple sclerosis also have problems with their bowels. Those with ... PA: Elsevier Saunders; 2016:chap 18. Read More Multiple sclerosis Recovering after stroke Patient Instructions Constipation - self-care ...

  13. Analysis of 178 penetrating stomach and small bowel injuries.

    PubMed

    Salim, Ali; Teixeira, Pedro G R; Inaba, Kenji; Brown, Carlos; Browder, Timothy; Demetriades, Demetrios

    2008-03-01

    Surgical site infections (SSIs), such as wound infection, fascial dehiscence, and intraabdominal abscess, commonly occur following penetrating abdominal trauma. However, most of the literature involves penetrating colon injuries. There are few reports describing complications following penetrating stomach and small bowel injuries. Based on the hypothesis that SSIs are commonly found following penetrating stomach and small bowel trauma, a prospective observational study was performed at an academic Level I trauma center from March 1, 2004 until August 31, 2006. The subjects were patients who had sustained a penetrating injury to the stomach or small bowel. Patients were followed for the development of an SSI, defined as wound infection, fascial dehiscence, or intraabdominal abscess. A total of 178 patients were admitted with penetrating stomach or small bowel injuries over the 29-month period. There were 121 (68%) gunshot injuries and 57 (32%) stab wounds. Associated intraabdominal injuries occurred in 74% of patients. Overall, SSIs occurred in 20% of cases. Risk factors for SSI included associated duodenal or colon injury, whereas time to operating room, blood loss, and type and duration of antibiotic use were not. When associated colon injuries were excluded, SSIs occurred in 16% of patients with gastric injuries and 13% of those with small bowel injuries. SSIs commonly follow penetrating stomach and small bowel trauma. Risk factors for SSI include associated duodenal or colon injury. Delay to operating room, blood loss, and type and length of antibiotic prophylaxis were not associated with an increased risk of SSI.

  14. Giant dedifferentiated liposarcoma of small bowel mesentery: a case report.

    PubMed

    Meher, Susanta; Mishra, Tushar Subhadarshan; Rath, Satyajit; Sasmal, Prakash Kumar; Mishra, Pritinanda; Patra, Susama

    2016-09-21

    Dedifferentiated liposarcoma is an uncommon variant of liposarcoma, with poor prognosis and higher preponderance to local recurrence. Only nine cases of dedifferentiated liposarcoma of small bowel mesentery have been reported till now. This is a case of giant dedifferentiated liposarcoma of the small bowel mesentery, weighing nearly 9 kg (19.8 lbs), with synchronous lesions in the extraperitoneal space, which is the first such case to be reported. We report a case of a 62-year-old man, who presented with a huge abdominal mass occupying nearly the entire abdomen. A contrast enhanced computed tomography of abdomen and pelvis revealed a large, poorly enhancing, heterogeneous, lobulated mass of size 27 × 16 cm, displacing the bowel loops peripherally. At laparotomy, a large mass arising from the small bowel mesentery was found. In addition, many other smaller synchronous lesions were studded in the entire small bowel mesentery and a couple more in the extraperitoneal space. A palliative excision of the giant mass along with the adjacent small bowel was done. The other smaller swellings were not causing any mass effect and were left behind as they were numerous, virtually ruling out any possibility of a curative excision. The histopathological examination suggested the diagnosis of dedifferentiated liposarcoma. On immunohistochemistry, S-100 was positive in the well-differentiated sarcomatous areas. The CD 117 and SMA were strongly negative ruling out the possibility of a gastrointestinal stromal tumour. The CD 34 however was positive in the tumour cells. Dedifferentiated liposarcoma of the small bowel mesentery is rare. Involvement of nearly whole of the small bowel mesentery in the disease process virtually rules out the possibility of a curative resection, the mainstay of management. This report would add to the knowledge of this rare disease and the possible therapeutic problem that may be encountered in case of multifocal disease.

  15. 21 CFR 184.1434 - Magnesium phosphate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium phosphate. 184.1434 Section 184.1434 Food... Specific Substances Affirmed as GRAS § 184.1434 Magnesium phosphate. (a) Magnesium phosphate includes both magnesium phosphate, dibasic, and magnesium phosphate, tribasic. Magnesium phosphate, dibasic (MgHPO4·3H2O...

  16. 21 CFR 184.1434 - Magnesium phosphate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Magnesium phosphate. 184.1434 Section 184.1434... GRAS § 184.1434 Magnesium phosphate. (a) Magnesium phosphate includes both magnesium phosphate, dibasic, and magnesium phosphate, tribasic. Magnesium phosphate, dibasic (MgHPO4·3H2O, CAS Reg. No. 7782-0975...

  17. Small bowel endoluminal imaging (capsule and enteroscopy)

    PubMed Central

    Murino, Alberto

    2017-01-01

    Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice. PMID:28839900

  18. Small bowel endoluminal imaging (capsule and enteroscopy).

    PubMed

    Murino, Alberto; Despott, Edward J

    2017-04-01

    Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice.

  19. Predictors of Bowel Function in Long-term Rectal Cancer Survivors with Anastomosis.

    PubMed

    Alavi, Mubarika; Wendel, Christopher S; Krouse, Robert S; Temple, Larissa; Hornbrook, Mark C; Bulkley, Joanna E; McMullen, Carmit K; Grant, Marcia; Herrinton, Lisa J

    2017-11-01

    Bowel function in long-term rectal cancer survivors with anastomosis has not been characterized adequately. We hypothesized that bowel function is associated with patient, disease, and treatment characteristics. The cohort study included Kaiser Permanente members who were long-term (≥5 years) rectal cancer survivors with anastomosis. Bowel function was scored using the self-administered, 14-item Memorial Sloan-Kettering Cancer Center Bowel Function Index. Patient, cancer, and treatment variables were collected from the electronic medical chart. We used multiple regression to assess the relationship of patient- and treatment-related variables with the bowel function score. The study included 381 anastomosis patients surveyed an average 12 years after their rectal cancer surgeries. The total bowel function score averaged 53 (standard deviation, 9; range, 31-70, higher scores represent better function). Independent factors associated with worse total bowel function score included receipt of radiation therapy (yes vs. no: 5.3-unit decrement, p < 0.0001), tumor distance from the anal verge (≤6 cm vs. >6 cm: 3.2-unit decrement, p < 0.01), and history of a temporary ostomy (yes vs. no: 4.0-unit decrement, p < 0.01). One factor measured at time of survey was also associated with worse total bowel function score: ever smoking (2.3-unit decrement, p < 0.05). The regression model explained 20% of the variation in the total bowel function score. Low tumor location, radiation therapy, temporary ostomy during initial treatment, and history of smoking were linked with decreased long-term bowel function following an anastomosis. These results should improve decision-making about surgical options.

  20. Role of Phosphate Transport System Component PstB1 in Phosphate Internalization by Nostoc punctiforme.

    PubMed

    Hudek, L; Premachandra, D; Webster, W A J; Bräu, L

    2016-11-01

    In bacteria, limited phosphate availability promotes the synthesis of active uptake systems, such as the Pst phosphate transport system. To understand the mechanisms that facilitate phosphate accumulation in the cyanobacterium Nostoc punctiforme, phosphate transport systems were identified, revealing a redundancy of Pst phosphate uptake systems that exists across three distinct operons. Four separate PstB system components were identified. pstB1 was determined to be a suitable target for creating phenotypic mutations that could result in the accumulation of excessive levels of phosphate through its overexpression or in a reduction of the capacity to accumulate phosphate through its deletion. Using quantitative real-time PCR (qPCR), it was determined that pstB1 mRNA levels increased significantly over 64 h in cells cultured in 0 mM added phosphate and decreased significantly in cells exposed to high (12.8 mM) phosphate concentrations compared to the level in cells cultured under normal (0.8 mM) conditions. Possible compensation for the loss of PstB1 was observed when pstB2, pstB3, and pstB4 mRNA levels increased, particularly in cells starved of phosphate. The overexpression of pstB1 increased phosphate uptake by N. punctiforme and was shown to functionally complement the loss of PstB in E. coli PstB knockout (PstB - ) mutants. The knockout of pstB1 in N. punctiforme did not have a significant effect on cellular phosphate accumulation or growth for the most part, which is attributed to the compensation for the loss of PstB1 by alterations in the pstB2, pstB3, and pstB4 mRNA levels. This study provides novel in vivo evidence that PstB1 plays a functional role in phosphate uptake in N. punctiforme IMPORTANCE: Cyanobacteria have been evolving over 3.5 billion years and have become highly adept at growing under limiting nutrient levels. Phosphate is crucial for the survival and prosperity of all organisms. In bacteria, limited phosphate availability promotes the

  1. Enhancing phosphate adsorption by Mg/Al layered double hydroxide functionalized biochar with different Mg/Al ratios.

    PubMed

    Li, Ronghua; Wang, Jim J; Zhou, Baoyue; Awasthi, Mukesh Kumar; Ali, Amjad; Zhang, Zengqiang; Gaston, Lewis A; Lahori, Altaf Hussain; Mahar, Amanullah

    2016-07-15

    Mg/Al ratio plays a significant role for anion adsorption by Mg/Al-layered double hydroxides (Mg/Al-LDHs) modified biochar. In this study, Mg/Al-LDHs biochar with different Mg/Al ratios (2, 3, 4) were prepared by co-precipitation for phosphate removal from aqueous solution. Factors on phosphate adsorption including Mg/Al ratio, pH, and the presence of other inorganic anions were investigated through batch experiments. Increasing Mg/Al ratio in the Mg/Al-LDHs biochar composites generally enhanced phosphate adsorption with Langmuir adsorption maximum calculated at 81.83mg phosphorous (P) per gram of 4:1Mg/Al-LDHs biochar at pH3.0. The adsorption process was best described by the pseudo-second-order kinetic model. Solution pH had greater effects on the phosphate adsorption by Mg/Al LDHs biochar composites with lower Mg/Al ratios. The presence of other inorganic anions decreased the phosphate adsorption efficiency in the order of F(-) > SO4(2-) > NO2(-) >Cl(-). Phosphate adsorption mechanism involves ion exchange, electrostatic attraction and surface inner-sphere complex formation. Overall, Mg/Al-LDHs biochar composites offer a potential alternative of carbon-based adsorbent for phosphate removal from aqueous solution. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Small Bowel Prolapse (Enterocele)

    MedlinePlus

    ... heavy lifting Being overweight or obese Pregnancy and childbirth Pregnancy and childbirth are the most common causes of pelvic organ ... of developing small bowel prolapse include: Pregnancy and childbirth. Vaginal delivery of one or more children contributes ...

  3. [Preparation for colonoscopy: types of scales and cleaning products].

    PubMed

    Lorenzo-Zúñiga, Vicente; Moreno-de-Vega, Vicente; Boix, Jaume

    2012-08-01

    Adequate bowel preparation is essential before a colonoscopy, allowing us to make a proper examination of the entire mucosa. The ideal method of colon cleansing should be fast, safe, and get a proper cleaning with minimal discomfort for the patient. Today we have a wide variety of colon cleansing products, information sometimes becomes confused. A good colon preparation depends partly on correct choice of the same, but also upon dietary restriction. Knowledge of all these products, with their advantages and limitations, we can make a better selection for each patient, and although the efficacy is comparable, is the experience of the browser, patient preferences, and the degree of compliance with the instructions preparation, which greatly influence the results.

  4. Adverse Perinatal Conditions Associated With Prenatally Detected Fetal Echogenic Bowel in Nova Scotia.

    PubMed

    Findley, Rachelle; Allen, Victoria M; Brock, Jo-Ann K

    2018-05-01

    This study sought to estimate the association of adverse perinatal outcomes with pregnancies complicated by fetal echogenic bowel. Data for pregnancies complicated with echogenic bowel identified in the second trimester were derived from the tertiary referral IWK Health Centre (Halifax, NS) Viewpoint Ultrasound Database augmented by medical chart review. The study was undertaken between 2003 and 2014. Rates of positive cytomegalovirus and toxoplasmosis infection were determined using maternal serology and amniocentesis results. Rates of intrauterine growth restriction, abnormal karyotype, cystic fibrosis, antenatal bleeding, and bowel abnormalities were also determined. Neonatal information included newborn urine culture results and postnatal genetic testing. Univariate analyses compared rates of infection with isolated echogenic bowel and echogenic bowel with other ultrasound findings, with statistical significance set at P <0.05. There were 422 pregnancies identified prenatally with echogenic bowel (82% had isolated echogenic bowel). Of these, 92 (22%) had at least one of the foregoing associated abnormalities. Three percent of women had serologic test results positive for cytomegalovirus or toxoplasmosis, with <1% documented newborn infections. Cystic fibrosis and other genetic diagnoses were observed in 8%, intrauterine growth restriction in 14%, antenatal bleeding in 19%, and bowel abnormalities in 3% of the cases of echogenic bowel. Pregnancies with isolated echogenic bowel had an 80% reduction in risk for these significant outcomes, in contrast to a four- to 11-fold increased risk of specific outcomes when additional ultrasound findings were present. An overall rate of adverse conditions of 22% with prenatally detected echogenic bowel serves to inform women and health care providers and emphasizes the importance of careful screening fetal ultrasound studies and timely referral for comprehensive assessment with findings of echogenic bowel for evaluation for

  5. Meckel diverticulum causing small bowel obstruction

    PubMed Central

    Sharples, Alistair James

    2010-01-01

    A 62-year-old man was admitted with generalised abdominal pain, constipation and vomiting. His abdomen was markedly distended and tender on general examination with signs of local peritonism in the left iliac fossa. He was initially diagnosed with likely acute diverticulitis and treated conservatively. A CT scan the next day showed fluid filled, dilated small bowel loops consistent with small bowel obstruction and there was a suggestion of an abscess in the left iliac fossa region. An urgent laparotomy was performed, which identified a perforated Meckel diverticulum. PMID:22479299

  6. Reinforcement Strategies for Load-Bearing Calcium Phosphate Biocements

    PubMed Central

    Geffers, Martha; Groll, Jürgen; Gbureck, Uwe

    2015-01-01

    Calcium phosphate biocements based on calcium phosphate chemistry are well-established biomaterials for the repair of non-load bearing bone defects due to the brittle nature and low flexural strength of such cements. This article features reinforcement strategies of biocements based on various intrinsic or extrinsic material modifications to improve their strength and toughness. Altering particle size distribution in conjunction with using liquefiers reduces the amount of cement liquid necessary for cement paste preparation. This in turn decreases cement porosity and increases the mechanical performance, but does not change the brittle nature of the cements. The use of fibers may lead to a reinforcement of the matrix with a toughness increase of up to two orders of magnitude, but restricts at the same time cement injection for minimal invasive application techniques. A novel promising approach is the concept of dual-setting cements, in which a second hydrogel phase is simultaneously formed during setting, leading to more ductile cement–hydrogel composites with largely unaffected application properties.

  7. Utility of CT in the diagnosis and management of small-bowel obstruction in children.

    PubMed

    Wang, Qiuyan; Chavhan, Govind B; Babyn, Paul S; Tomlinson, George; Langer, Jacob C

    2012-12-01

    CT is often used in the diagnosis and management of small-bowel obstruction in children. To determine sensitivity of CT in delineating presence, site and cause of small-bowel obstruction in children. We retrospectively reviewed the CT scans of 47 children with surgically proven small-bowel obstruction. We noted any findings of obstruction and the site and cause of obstruction. Presence, absence or equivocal findings of bowel obstruction on abdominal radiographs performed prior to CT were also noted. We reviewed patient charts for clinical details and surgical findings, including bowel resection. Statistical analysis was performed using Fisher exact test to determine which CT findings might predict bowel resection. CT correctly diagnosed small-bowel obstruction in 43/47 (91.5%) cases. CT correctly indicated site of obstruction in 37/47 (78.7%) cases and cause of obstruction in 32/47 (68.1%) cases. Small-bowel feces sign was significantly associated with bowel resection at surgery (P = 0.0091). No other CT finding was predictive of bowel resection. Out of 41 children who had abdominal radiographs before CT, 29 (70.7%) showed unequivocal obstruction, six (14.6%) showed equivocal findings and six (14.6%) were unremarkable. CT is highly sensitive in diagnosing small-bowel obstruction in children and is helpful in determining the presence of small-bowel obstruction in many clinically suspected cases with equivocal or normal plain radiographs. CT also helps to determine the site and cause of the obstruction with good sensitivity.

  8. Inflammatory cells implicated in neoplasia development in idiopathic inflammatory bowel disease.

    PubMed

    Hashash, Jana G; Hartman, Douglas J

    2017-11-10

    The inflammatory mechanisms that lead to the clinical symptoms that are grouped under the term inflammatory bowel disease have not been fully characterized. Although a specific mechanism has not been identified, inflammatory bowel disease is believed to be related to an inability by the immune system to shut active inflammation within the intestine. Many contributing factors have been implicated in the disease process. Based on population studies, patients with inflammatory bowel disease have an increased risk for neoplastic development. Although no specific immune cell has been implicated in neoplastic development within this patient population, several immune cells have been implicated as possible etiologies in inflammatory bowel disease. In this review, we will review the clinical evidence about the risk for neoplastic development in inflammatory bowel disease and the current clinical guidelines to survey this patient population. We will also review the pathologic assessment of inflammation within this patient population as well the underlying immune cells and cytokines that have been implicated in the etiology of inflammatory bowel disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Mg-Enriched Engineered Carbon from Lithium-Ion Battery Anode for Phosphate Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yan; Guo, Xingming; Yao, Ying

    2016-02-10

    Three Mg-enriched engineered carbons (mesocarbon microbeads, MCMB) were produced from lithium-ion battery anode using concentrated nitric acid oxidization and magnesium nitrate pretreatment. The obtained 15%Mg-MCMB, 30%Mg-MCMB, and 40%Mg-MCMB have magnesium level of 10.19, 19.13, and 19.96%, respectively. FTIR spectrum shows the functional groups present on the oxidized MCMB including OH, C=O, C–H, and C–O. XRD, SEM-EDX, and XPS analyses show that nanoscale Mg(OH) 2 and MgO particles were presented on the surface of the Mg-MCMB samples, which could serve as the main adsorption mechanism as to precipitate phosphate from aqueous solutions. The sorption experiments indicate that Mg modification dramatically promotesmore » MCMB’s phosphate removal ability and phosphate removal rates reach as high as 95%. Thus, modification of the spent LIBs anode could provide a novel direction of preparing wastewater adsorbent and develop an innovative way to achieve sustainable development.« less

  10. Small bowel capsule endoscopy in 2007: Indications, risks and limitations

    PubMed Central

    Rondonotti, Emanuele; Villa, Federica; Mulder, Chris JJ; Jacobs, Maarten AJM; de Franchis, Roberto

    2007-01-01

    Capsule endoscopy has revoluzionized the study of the small bowel by providing a reliable method to evaluate, endoscopically, the entire small bowel. In the last six years several papers have been published exploring the possible role of this examination in different clinical conditions. At the present time capsule endoscopy is generally recommended as a third examination, after negative bidirectional endoscopy, in patients with obscure gastrointestinal bleeding. A growing body of evidence suggests also an important role for this examination in other clinical conditions such as Crohn’s disease, celiac disease, small bowel polyposis syndromes or small bowel tumors. The main complication of this examination is the retention of the device at the site of a previously unknown small bowel stricture. However there are also some other open issues mainly due to technical limitations of this tool (which is not driven from remote control, is unable to take biopsies, to insufflate air, to suck fluids or debris and sometimes to correctly size and locate lesions).The recently developed double balloon enteroscope, owing to its capability to explore a large part of the small bowel and to take targeted biopsies, although being invasive and time consuming, can overcome some limitations of capsule endoscopy. At the present time, in the majority of clinical conditions (i.e. obscure GI bleeding), the winning strategy seems to be to couple these two techniques to explore the small bowel in a painless, safe and complete way (with capsule endoscopy) and to define and treat the lesions identified (with double balloon enteroscopy). PMID:18069752

  11. Contouring and Constraining Bowel on a Full-Bladder Computed Tomography Scan May Not Reflect Treatment Bowel Position and Dose Certainty in Gynecologic External Beam Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaparpalvi, Ravindra, E-mail: ryaparpa@montefiore.org; Mehta, Keyur J.; Bernstein, Michael B.

    Purpose: To evaluate, in a gynecologic cancer setting, changes in bowel position, dose-volume parameters, and biological indices that arise between full-bladder (FB) and empty-bladder (EB) treatment situations; and to evaluate, using cone beam computed tomography (CT), the validity of FB treatment presumption. Methods and Materials: Seventeen gynecologic cancer patients were retrospectively analyzed. Empty-bladder and FB CTs were obtained. Full-bladder CTs were used for planning and dose optimization. Patients were given FB instructions for treatment. For the study purpose, bowel was contoured on the EB CTs for all patients. Bowel position and volume changes between FB and EB states were determined.more » Full-bladder plans were applied on EB CTs for determining bowel dose-volume changes in EB state. Biological indices (generalized equivalent uniform dose and normal tissue complication probability) were calculated and compared between FB and EB. Weekly cone beam CT data were available in 6 patients to assess bladder volume at treatment. Results: Average (±SD) planned bladder volume was 299.7 ± 68.5 cm{sup 3}. Median bowel shift in the craniocaudal direction between FB and EB was 12.5 mm (range, 3-30 mm), and corresponding increase in exposed bowel volume was 151.3 cm{sup 3} (range, 74.3-251.4 cm{sup 3}). Absolute bowel volumes receiving 45 Gy were higher for EB compared with FB (mean 328.0 ± 174.8 vs 176.0 ± 87.5 cm{sup 3}; P=.0038). Bowel normal tissue complication probability increased 1.5× to 23.5× when FB planned treatments were applied in the EB state. For the study, the mean percentage value of relative bladder volume at treatment was 32%. Conclusions: Full-bladder planning does not necessarily translate into FB treatments, with a patient tendency toward EB. Given the uncertainty in daily control over bladder volume for treatment, we strongly recommend a “planning-at-risk volume bowel” (PRV{sub B}owel) concept to account for bowel

  12. Risk factors for bowel dysfunction after sphincter-preserving rectal cancer surgery: a prospective study using the Memorial Sloan Kettering Cancer Center bowel function instrument.

    PubMed

    Ihn, Myong Hoon; Kang, Sung-Bum; Kim, Duck-Woo; Oh, Heung-Kwon; Lee, Soo Young; Hong, Sa Min

    2014-08-01

    Until recently, no studies have prospectively evaluated bowel function after sphincter-preserving surgery for rectal cancer with the use of a validated bowel function scoring system. The aim of this study was to investigate possible risk factors for altered bowel function after sphincter-preserving surgery. This was a prospective study. The study was conducted between January 2006 and May 2012 at the authors' institution. Patients who underwent sphincter-preserving rectal cancer surgery were recruited. Bowel function was assessed 1 day before (baseline) and at 1 year after sphincter-preserving surgery or temporary ileostomy takedown with the use of the Memorial Sloan Kettering Cancer Center questionnaire. Multivariable analysis was performed to identify the factors associated with altered bowel function after surgery. Overall, 266 patients were eligible for the analysis. The tumor was located in the upper, middle, and lower rectum in 68 (25.5%), 113 (42.5%), and 85 (32.0%) patients. Intersphincteric resection and temporary ileostomy were performed in 18 (6.8%) and 129 (48.5%) patients. The mean Memorial Sloan Kettering Cancer Center score was 64.5 ± 7.6 at 1 year after sphincter-preserving surgery or temporary ileostomy takedown. The Memorial Sloan Kettering Cancer Center score decreased in 163/266 patients (61.3%) between baseline and 1 year after surgery. Tumor location (p = 0.01), operative method (p = 0.03), anastomotic type (p = 0.01), and temporary ileostomy (p = 0.01) were associated with altered bowel function after sphincter-preserving surgery in univariate analyses. In multivariable analysis, only tumor location was independently associated with impaired bowel function after sphincter-preserving rectal cancer surgery. This study was limited by its nonrandomized design and the lack of measurement before preoperative chemoradiotherapy. We suggest that preoperative counseling should be implemented to inform patients of the risk of bowel dysfunction

  13. [Coexistence of coeliac disease and inflammatory bowel disease in children].

    PubMed

    Krawiec, Paulina; Pawłowska-Kamieniak, Agnieszka; Pac-Kożuchowska, Elżbieta; Mroczkowska-Juchkiewcz, Agnieszka; Kominek, Katarzyna

    2016-01-01

    Coeliac disease and inflammatory bowel disease are chronic inflammatory conditions of gastrointestinal tract with complex aetiology with genetic, environmental and immunological factors contributing to its pathogenesis. It was noted that immune-mediated disorders often coexist. There is well-known association between coeliac disease and type 1 diabetes and ulcerative colitis and primary sclerosing cholangitis. However, growing body of literature suggests the association between coeliac disease and inflammatory bowel disease, particularly ulcerative colitis. This is an extremely rare problem in paediatric gastroenterology. To date there have been reported several cases of children with coexisting coeliac disease and inflammatory bowel disease. Herewith we present review of current literature on coexistence of coeliac disease and inflammatory bowel disease in children. © 2016 MEDPRESS.

  14. Most small bowel cancers are revealed by a complication

    PubMed Central

    Negoi, Ionut; Paun, Sorin; Hostiuc, Sorin; Stoica, Bodgan; Tanase, Ioan; Negoi, Ruxandra Irina; Beuran, Mircea

    2015-01-01

    ABSTRACT Objective To characterize the pattern of primary small bowel cancers in a tertiary East-European hospital. Methods A retrospective study of patients with small bowel cancers admitted to a tertiary emergency center, over the past 15 years. Results There were 57 patients with small bowel cancer, representing 0.039% of admissions and 0.059% of laparotomies. There were 37 (64.9%) men, mean age of 58 years; and 72 years for females. Out of 57 patients, 48 (84.2%) were admitted due to an emergency situation: obstruction in 21 (38.9%), perforation in 17 (31.5%), upper gastrointestinal bleeding in 8 (14.8%), and lower gastrointestinal bleeding in 2 (3.7%). There were 10 (17.5%) duodenal tumors, 21 (36.8%) jejunal tumors and 26 (45.6%) ileal tumors. The most frequent neoplasms were gastrointestinal stromal tumor in 24 patients (42.1%), adenocarcinoma in 19 (33.3%), lymphoma in 8 (14%), and carcinoids in 2 (3.5%). The prevalence of duodenal adenocarcinoma was 14.55 times greater than that of the small bowel, and the prevalence of duodenal stromal tumors was 1.818 time greater than that of the small bowel. Obstruction was the complication in adenocarcinoma in 57.9% of cases, and perforation was the major local complication (47.8%) in stromal tumors. Conclusion Primary small bowel cancers are usually diagnosed at advanced stages, and revealed by a local complication of the tumor. Their surgical management in emergency setting is associated to significant morbidity and mortality rates. PMID:26676271

  15. [Irritable bowel syndrome: a functional disorder?].

    PubMed

    Man, Fernando; Bustos Fernández, Luis María

    2013-12-01

    Irritable bowel syndrome is a highly prevalent condition responsible for almost one third of visits to the gastroenterologist and huge expenses for diagnosis, treatment and loss of working days. A unique pathophysiologic mechanism has not been elucidated yet and several possibilities have been proposed such as senso-perception and motor disturbances, the effect of stress and anxiety, serotonin receptor failures, activation of abnormal brain areas and pain modulation differences, among others. The absence of a biological marker has led the investigators to consider this syndrome as an exclusion diagnostic condition, once the organic diseases have been discarded The changes in gut microbiota have recently raised great interest among gastroenterologists. The study of the small intestinal bowel overgrowth syndrome, the effect of antibiotics upon the flora, the recognition of post-infectious irritable bowel syndrome and the action of probiotics, together with the effect of malabsortion of diet carbohydrates have brought some new light in our knowledge. The present update will focus on the published evidence about the subject, bearing in mind that the mechanisms elicited here are only suitable for a subgroup of patients.

  16. Phosphate transporter mediated lipid accumulation in Saccharomyces cerevisiae under phosphate starvation conditions.

    PubMed

    James, Antoni W; Nachiappan, Vasanthi

    2014-01-01

    In the current study, when phosphate transporters pho88 and pho86 were knocked out they resulted in significant accumulation (84% and 43%) of triacylglycerol (TAG) during phosphate starvation. However in the presence of phosphate, TAG accumulation was only around 45% in both pho88 and pho86 mutant cells. These observations were confirmed by radio-labeling, fluorescent microscope and RT-PCR studies. The TAG synthesizing genes encoding for acyltransferases namely LRO1 and DGA1 were up regulated. This is the first report for accumulation of TAG in pho88Δ and pho86Δ cells under phosphate starvation conditions. Copyright © 2013. Published by Elsevier Ltd.

  17. Do Intra-anal Bowel Management Devices Reduce Incontinence-Associated Dermatitis and/or Pressure Injuries?

    PubMed

    Beeson, Terrie; Eifrid, Bethany; Pike, Caitlin A; Pittman, Joyce

    The purpose of this article was to examine the evidence and provide recommendations related to the effectiveness of intra-anal bowel management systems including intra-anal bowel catheters and rectal trumpets in reducing incontinence-associated dermatitis and pressure injuries. Does the use of an intra-anal bowel management system (intra-anal bowel catheter or rectal trumpet) reduce incontinence-associated skin damage and/or hospital-acquired pressure injuries in the acute care adult patient population? A search of the literature was performed by a trained university librarian, which resulted in 133 articles that examined intra-anal bowel management systems (intra-anal bowel catheter and rectal trumpet), incontinence-associated dermatitis, and pressure injuries. A systematic approach was used to review titles, abstracts, and text yielding 6 studies that met inclusion criteria. Strength of the evidence was rated using rating methodology from Essential Evidence Plus: Levels of evidence and Oxford Center for Evidence-based Medicine, adapted by Gray and colleagues. Five of the 6 studies reported positive results concerning the effectiveness of intra-anal bowel management systems to reduce incontinence-associated dermatitis and/or pressure injuries. One randomized control trial found no improvement in incontinence-associated dermatitis in the intra-anal bowel management system (intra-anal bowel catheter or rectal trumpet) groups or pressure injuries as compared to usual care. The strength of the evidence for the identified studies was moderate (2 level A, 3 level B, and 1 level C). An important finding in 2 of the studies was the safety of the intra-anal bowel management systems-both intra-anal bowel catheter and rectal trumpet. Evidence indicates intra-anal bowel management system (intra-anal bowel catheters and rectal trumpet) provides a viable option for fecal incontinence management and these devices reduce incontinence-associated dermatitis and/or pressure injuries.

  18. Extensive small bowel intramural haematoma secondary to warfarin

    PubMed Central

    Clement, Zackariah

    2017-01-01

    Abstract Intramural haematoma is a rare complication of oral anticoagulant therapy, occurring in  1 in 2500 patients treated with warfarin. This report describes a 71-year-old gentleman who presented with tachycardia, vomiting and abdominal distension on a background of anticoagulation for a metallic aortic valve. He was found to have a supratherapeutic international normalized ratio (INR) of 9.9 with an extensive small bowel intramural haematoma and secondary small bowel obstruction. He was successfully managed non-operatively with fluid resuscitation, INR reversal, bowel rest and nasogastric decompression. The patient's presentation was atypical with a lack of classic symptoms such as abdominal pain. This highlights the importance of considering intramural haematoma as a differential diagnosis for gastrointestinal symptoms in anticoagulated patients. PMID:28458850

  19. Extensive small bowel intramural haematoma secondary to warfarin.

    PubMed

    Limmer, Alexandra M; Clement, Zackariah

    2017-03-01

    Intramural haematoma is a rare complication of oral anticoagulant therapy, occurring in  1 in 2500 patients treated with warfarin. This report describes a 71-year-old gentleman who presented with tachycardia, vomiting and abdominal distension on a background of anticoagulation for a metallic aortic valve. He was found to have a supratherapeutic international normalized ratio (INR) of 9.9 with an extensive small bowel intramural haematoma and secondary small bowel obstruction. He was successfully managed non-operatively with fluid resuscitation, INR reversal, bowel rest and nasogastric decompression. The patient's presentation was atypical with a lack of classic symptoms such as abdominal pain. This highlights the importance of considering intramural haematoma as a differential diagnosis for gastrointestinal symptoms in anticoagulated patients.

  20. Clinical Aspects of Idiopathic Inflammatory Bowel Disease: A Review for Pathologists.

    PubMed

    Lee, Hwajeong; Westerhoff, Maria; Shen, Bo; Liu, Xiuli

    2016-05-01

    -Idiopathic inflammatory bowel disease manifests with different clinical phenotypes showing varying behavior and risk for neoplasia. The clinical questions that are posed to pathologists differ depending on phase of the disease and the clinical circumstances. Understanding the clinical aspects of the dynamic disease process will enhance the role of pathology in optimizing the care of patients with inflammatory bowel disease. -To review clinical and surgical aspects of inflammatory bowel disease that are relevant to practicing pathologists. -The literature was reviewed. -Diagnosis and management of inflammatory bowel disease require an integrated evaluation of clinical, endoscopic, radiologic, and pathologic features. Therefore, close interaction between clinicians and pathologists is crucial. Having this team approach improves understanding of the pertinent clinical and surgical aspects of the disease and assists in the recognition of unusual presentation of variants, as well as mimics of idiopathic inflammatory bowel disease, by pathologists.

  1. Lubiprostone plus PEG electrolytes versus placebo plus PEG electrolytes for outpatient colonoscopy preparation: a randomized, double-blind placebo-controlled trial.

    PubMed

    Sofi, Aijaz A; Nawras, Ali T; Pai, Chetan; Samuels, Qiana; Silverman, Ann L

    2015-01-01

    Bowel preparation using large volume of polyethylene glycol (PEG) solutions is often poorly tolerated. Therefore, there are ongoing efforts to develop an alternative bowel cleansing regimen that should be equally effective and better tolerated. The aim of this study was to assess the efficacy of lubiprostone (versus placebo) plus PEG as a bowel cleansing preparation for colonoscopy. Our study was a randomized, double-blind placebo-controlled design. Patients scheduled for screening colonoscopy were randomized 1:1 to lubiprostone (group 1) or placebo (group 2) plus 1 gallon of PEG. The primary endpoints were patient's tolerability and endoscopist's evaluation of the preparation quality. The secondary endpoint was to determine any reduction in the amount of PEG consumed in the lubiprostone group compared with the placebo group. One hundred twenty-three patients completed the study and were included in the analysis. There was no difference in overall cleanliness. The volume of PEG was similar in both the groups. The volume of PEG approached significance as a predictor of improved score for both the groups (P = 0.054). Lubiprostone plus PEG was similar to placebo plus PEG in colon cleansing and volume of PEG consumed. The volume of PEG consumed showed a trend toward improving the quality of the colon cleansing.

  2. Mesoporous Phosphate Heterostructures: Synthesis and Application on Adsorption and Catalysis

    NASA Astrophysics Data System (ADS)

    Moreno-Tost, Ramón; Jiménez-Jiménez, José; Infantes-Molina, Antonia; Cavalcante, Celio L.; Azevedo, Diana C. S.; Soriano, María Dolores; López Nieto, José Manuel; Jiménez-López, Antonio; Rodríguez-Castellón, Enrique

    Porous phosphate heterostructures (PPHs) are solids formed by a layered metal(IV) phosphate expanded with silica galleries obtained by combining the two main strategies for obtaining mesoporous materials [pillared layered structures (PLS') and MCM-41]. The different synthetic pathways for obtaining mesoporous phosphate structures with silica galleries with Zr- or Ti-doped silica, the study of their structural, textural and acid properties, its functionalisation with different organic substances such as propionitrile, 3-aminopropyl triethoxysilane, (3-mercaptopropyl)trimethoxysilane, vinyltrimethoxysilane, phenyltriethoxysilane and 3-(triethoxysilyl)propionitrile are discussed. The preparation of metal-supported catalysts and their application in gas separation, adsorption and catalysis are reviewed. Specifically, the use of Cu- and Fe-exchanged PPH for the adsorption of benzothiophene and the separation of propane/propene is the main application as adsorbent. The hydrotreating of aromatic hydrocarbons using ruthenium-impregnated catalysts via hydrogenation and hydrogenolysis/hydrocracking for the production of clean diesel fuels, the selective catalytic reduction of NO from stationary and mobile sources by using Cu-PPH with 1, 3 and 7 wt% of Cu and the selective oxidation of hydrogen sulphide to sulphur with vanadium-containing PPH are the three catalytic reactions of environmental interest studied.

  3. Nanoporous sorbent material as an oral phosphate binder and for aqueous phosphate, chromate, and arsenate removal

    PubMed Central

    Sangvanich, Thanapon; Ngamcherdtrakul, Worapol; Lee, Richard; Morry, Jingga; Castro, David; Fryxell, Glen E.; Yantasee, Wassana

    2014-01-01

    Phosphate removal is both biologically and environmentally important. Biologically, hyperphosphatemia is a critical condition in end-stage chronic kidney disease patients. Patients with hyperphosphatemia are treated long-term with oral phosphate binders to prevent phosphate absorption to the body by capturing phosphate in the gastrointestinal (GI) tract followed by fecal excretion. Environmentally, phosphate levels in natural water resources must be regulated according to limits set forth by the US Environmental Protection Agency. By utilizing nanotechnology and ligand design, we developed a new material to overcome limitations of traditional sorbent materials such as low phosphate binding capacity, slow binding kinetics, and negative interference by other anions. A phosphate binder based on iron-ethylenediamine on nanoporous silica (Fe-EDA-SAMMS) has been optimized for substrates and Fe(III) deposition methods. The Fe-EDA-SAMMS material had a 4-fold increase in phosphate binding capacity and a broader operating pH window compared to other reports. The material had a faster phosphate binding rate and was significantly less affected by other anions than Sevelamer HCl, the gold standard oral phosphate binder, and AG® 1-X8, a commercially available anion exchanger. It had less cytotoxicity to Caco-2 cells than lanthanum carbonate, another prescribed oral phosphate binder. The Fe-EDA-SAMMS also had high capacity for arsenate and chromate, two of the most toxic anions in natural water. PMID:25554735

  4. Probiotic Therapy for Irritable Bowel Syndrome

    PubMed Central

    Aragon, George; Graham, Deborah B.; Borum, Marie

    2010-01-01

    The etiology of irritable bowel syndrome (IBS) is thought to be multifactorial, with several factors (including alterations in gut motility, small-bowel bacterial overgrowth, microscopic inflammation, and visceral hypersensitivity) potentially playing a role. Recent studies have suggested that probiotics may be useful in the treatment of IBS. Although the exact mechanism for how probiotics may aid in the reduction of symptoms commonly found in IBS is unknown, the effects of probiotics on alterations in gut bacteria appear to play a part. This review focuses on recent studies examining the role of probiotics in the treatment of IBS. PMID:20567539

  5. Biofeedback & Bowel Disorders: Teaching Yourself to Live without the Problem

    MedlinePlus

    ... Personal Stories Contact Us Search Biofeedback & Bowel Disorders: Teaching Yourself to Live Without the Problem Home Biofeedback ... donation. Adapted from IFFGD Publication: Biofeedback & Bowel Disorders: Teaching Yourself to Live without the Problem by Mary ...

  6. Hydrothermal synthesis for new multifunctional materials: A few examples of phosphates and phosphonate-based hybrid materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rueff, Jean-Michel, E-mail: jean-michel.rueff@ensicaen.fr; Poienar, Maria; Guesdon, Anne

    Novel physical or chemical properties are expected in a great variety of materials, in connection with the dimensionality of their structures and/or with their nanostructures, hierarchical superstructures etc. In the search of new advanced materials, the hydrothermal technique plays a crucial role, mimicking the nature able to produce fractal, hyperbranched, urchin-like or snow flake structures. In this short review including new results, this will be illustrated by examples selected in two types of materials, phosphates and phosphonates, prepared by this method. The importance of the synthesis parameters will be highlighted for a magnetic iron based phosphates and for hybrids containingmore » phosphonates organic building units crystallizing in different structural types. - Graphical abstract: Phosphate dendrite like and phosphonate platelet crystals.« less

  7. Small bowel enteroclysis in surgically treated obesity.

    PubMed

    Coppola, V; Verrengia, D; Gatta, G; Alfinito, M; Alfano, L; D'Agostino, F

    1998-11-01

    To define the indications, technical limitations and diagnostic yeld of small bowel transbuccal enema in the follow-up of surgical jejunoileal shunting in patients with complicated severe essential obesity. Three patients were submitted to surgical diversion: two of them underwent an intestinal bypass after Payne-De Wind (isoperistaltic end-to-side jejunoileostomy) and the other after Scott (end-to-end jejunoileostomy). The latter refers to intestinal recanalization and antiperistaltic lower end-to-side gastroenteric restoration. Radiologic studies are the only means to depict the surgical small bowel. Radiographic follow-up needs barium sulfate administration and therefore cannot be performed any sooner than 30 days postoperatively. In the last three years the classic transbuccal enema has been performed with a Rollandi tube (with a terminal opening and a balloon). Both the anastomosis and the blind loop are difficult to demonstrate. Jejunoileal bypass can be used to treat severe obsity uncontrollable otherwise, to reduce food absorption. Different severe complications may result and small bowel studies may permit to show late local complications. Small bowel enema is also indispensable in bypass reversal. There are no alternatives to this radiologic examination which is however very difficult to perform, because of the changes made by previous operation(s), and to interpret because the anastomosis, the sutured loop and wall changes are often poorly demonstrated.

  8. Surface Modification of Zirconia Substrate by Calcium Phosphate Particles Using Sol-Gel Method.

    PubMed

    Jin, So Dam; Um, Sang Cheol; Lee, Jong Kook

    2015-08-01

    Surface modification with a biphasic composition of hydroxyapatite (HA) and tricalcium phosphate (TCP) was performed on a zirconia substrate using a sol-gel method. An initial calcium phosphate sol was prepared by mixing a solution of Ca(NO3)2 · 4H20 and (C2H5O)3P(O), while both porous and dense zirconia were used as substrates. The sol-gel coating was performed using a spin coater. The coated porous zirconia substrate was re-sintered at 1350 °C 2 h, while coated dense zirconia substrate was heat-treated at 750 °C 1 h. The microstructure of the resultant HA/TCP coatings was found to be dependent on the type of zirconia substrate used. With porous zirconia as a starting substrate, numerous isolated calcium phosphate particles (TCP and HA) were uniformly dispersed on the surface, and the particle size and covered area were dependent on the viscosity of the calcium phosphate sol. Conversely, when dense zirconia was used as a starting substrate, a thick film of nano-sized HA particles was obtained after heat treatment, however, substantial agglomeration and cracking was also observed.

  9. A precise method for the analysis of d18O of dissolved inorganic phosphate in seawater

    USGS Publications Warehouse

    McLaughlin, K.; Silva, S.; Kendall, C.; Stuart-Williams, Hilary; Paytan, A.

    2004-01-01

    A method for preparation and analysis of the oxygen isotope composition (d18O) of dissolved inorganic phosphate (DIP) has been developed and preliminary results for water samples from various locations are reported. Phosphate is extracted from seawater samples by coprecipitation with magnesium hydroxide. Phosphate is further purified through a series of precipitations and resin separation and is ultimately converted to silver phosphate. Silver phosphate samples are pyrolitically decomposed to carbon monoxide and analyzed for d18O. Silver phosphate samples weighing 0.7 mg (3.5 mol oxygen) can be analyzed routinely with an average standard deviation of about 0.3. There is no isotope fractionation during extraction and blanks are negligible within analytical error. Reproducibility was determined for both laboratory standards and natural samples by multiple analyses. A comparison between filtered and unfiltered natural seawater samples was also conducted and no appreciable difference was observed for the samples tested. The d18O values of DIP in seawater determined using this method range from 18.6 to 22.3, suggesting small but detectable natural variability in seawater. For the San Francisco Bay estuary DIP d18O is more variable, ranging from 11.4 near the San Joaquin River to 20.1 near the Golden Gate Bridge, and was well correlated with salinity, phosphate concentration, and d18O of water.

  10. Research on up- and down-conversion emissions of Er3+/Yb3+ co-doped phosphate glass ceramic

    NASA Astrophysics Data System (ADS)

    Ming, Chengguo; Song, Feng; An, Liqun; Ren, Xiaobin; Yuan, Yize; Cao, Yang; Wang, Gangzhi

    2012-12-01

    By high-temperature melting method and thermal treatment technology, Er3+/Yb3+ co-doped phosphate glass and glass ceramic samples were prepared. The luminescence spectra of the glass and glass ceramic samples were studied under 975 nm excitation. In visible and near-infrared bands, the emission intensity of the glass ceramic is stronger than that of the glass. The glass ceramic can comprehensively improve the luminous characters of the precursor glass. The phosphate glass ceramic will be valuable luminescence materials.

  11. Plain magnetic resonance imaging as an alternative in evaluating inflammation and bowel damage in inflammatory bowel disease--a prospective comparison with conventional magnetic resonance follow-through.

    PubMed

    Jesuratnam-Nielsen, Kayalvily; Løgager, Vibeke B; Rezanavaz-Gheshlagh, Bijan; Munkholm, Pia; Thomsen, Henrik S

    2015-05-01

    To compare prospectively the diagnostic accuracy of magnetic resonance imaging (MRI) without use of contrast medium orally or intravenously (plain MRI) with magnetic resonance follow-through (MRFT) in patients with inflammatory bowel disease (IBD). Plain MRI was carried out in addition to MRFT, to which the patients were referred. All patients underwent both examinations on the same day. For the evaluation, the bowel was divided into nine segments. Two radiologists, blinded to clinical findings, evaluated bowel wall thickness, diffusion weighted imaging (DWI), and other inflammatory changes in each bowel segments. Further, hyperenhancement of the bowel was also evaluated in MRFT. A total of 100 patients (40 males and 60 females; median age: 38.5; range: 19-90) were enrolled; 44 with Crohn's disease (CD), 25 with ulcerative colitis (UC), 24 with IBD unclassified (IBD-U), and 7 had other diagnosis. Sensitivity, specificity, and accuracy in CD ranged 50-86%, 93-94%, and 91-92% for wall thickening and 49-82%, 85-93%, and 84-89% for DWI, respectively. Sensitivity, specificity, and accuracy in UC range 0-40%, 87-100%, and 80-100% for wall thickening and 0-52%, 83-94% and 76-92% for DWI, respectively. The κ values for bowel wall thickening, DWI, and mural hyperenhancement were detected with fair agreement (κ = 0.26-0.39) at both MRI examinations, whereas only bowel wall thickening in MRFT were detected with moderate agreement (κ = 0.47) Conclusion. Plain MRI cannot currently replace MRFT in the workup of patients with IBD. Further research on plain MRI is needed to improve the protocol.

  12. Migrating gallstone: from Bouveret's syndrome to distal small bowel obstruction.

    PubMed

    Yau, Kwok-Kay; Siu, Wing-Tai; Tsui, Ka-Kin

    2006-06-01

    Gallstone ileus is an uncommon cause of small bowel obstruction. When the gallstone lodges inside the duodenum and causes gastric outlet obstruction, it is termed Bouveret's syndrome. However, it is rather unusual to seen the evolution of a migrating gallstone (from duodenum to distal small bowel) in a patient during the same hospital admission. We report a case of gallstone ileus from the initial presentation of gastric outlet obstruction to the development of distal small bowel obstruction within the same hospital admission, and its total laparoscopic treatment.

  13. Beliefs about personal control and self-management in 30-40 year olds living with Inflammatory Bowel Disease: a qualitative study.

    PubMed

    Cooper, Joanne M; Collier, Jacqueline; James, Veronica; Hawkey, Christopher J

    2010-12-01

    -management was a lack of knowledge and awareness by non-specialist health care staff, employers and the wider society. Nurses involved in the care of individuals with Inflammatory Bowel Disease should support and prepare patients for the discrepancies and uncertainties of living with the condition. Greater training about Inflammatory Bowel Disease is recommended, specifically for non-specialist health care staff and employers. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Recurrent intestinal volvulus in midgut malrotation causing acute bowel obstruction: A case report

    PubMed Central

    Sheikh, Fayed; Balarajah, Vickna; Ayantunde, Abraham Abiodun

    2013-01-01

    Intestinal malrotation occurs when there is a disruption in the normal embryological development of the bowel. The majority of patients present with clinical features in childhood, though rarely a first presentation can take place in adulthood. Recurrent bowel obstruction in patients with previous abdominal operation for midgut malrotation is mostly due to adhesions but very few reported cases have been due to recurrent volvulus. We present the case of a 22-year-old gentleman who had laparotomy in childhood for small bowel volvulus and then presented with acute bowel obstruction. Preoperative computerised tomography scan showed small bowel obstruction and features in keeping with midgut malrotation. Emergency laparotomy findings confirmed midgut malrotation with absent appendix, abnormal location of caecum, ascending colon and small bowel. In addition, there were small bowel volvulus and a segment of terminal ileal stricture. Limited right hemicolectomy was performed with excellent postoperative recovery. This case is presented to illustrate a rare occurrence and raise an awareness of the possibility of dreadful recurrent volvulus even several years following an initial Ladd’s procedure for midgut malrotation. Therefore, one will need to exercise a high index of suspicion and this becomes very crucial in order to ensure prompt surgical intervention and thereby preventing an attendant bowel ischaemia with its associated high fatality. PMID:23556060

  15. Recurrent intestinal volvulus in midgut malrotation causing acute bowel obstruction: A case report.

    PubMed

    Sheikh, Fayed; Balarajah, Vickna; Ayantunde, Abraham Abiodun

    2013-03-27

    Intestinal malrotation occurs when there is a disruption in the normal embryological development of the bowel. The majority of patients present with clinical features in childhood, though rarely a first presentation can take place in adulthood. Recurrent bowel obstruction in patients with previous abdominal operation for midgut malrotation is mostly due to adhesions but very few reported cases have been due to recurrent volvulus. We present the case of a 22-year-old gentleman who had laparotomy in childhood for small bowel volvulus and then presented with acute bowel obstruction. Preoperative computerised tomography scan showed small bowel obstruction and features in keeping with midgut malrotation. Emergency laparotomy findings confirmed midgut malrotation with absent appendix, abnormal location of caecum, ascending colon and small bowel. In addition, there were small bowel volvulus and a segment of terminal ileal stricture. Limited right hemicolectomy was performed with excellent postoperative recovery. This case is presented to illustrate a rare occurrence and raise an awareness of the possibility of dreadful recurrent volvulus even several years following an initial Ladd's procedure for midgut malrotation. Therefore, one will need to exercise a high index of suspicion and this becomes very crucial in order to ensure prompt surgical intervention and thereby preventing an attendant bowel ischaemia with its associated high fatality.

  16. CT imaging of blunt traumatic bowel and mesenteric injuries.

    PubMed

    LeBedis, Christina A; Anderson, Stephan W; Soto, Jorge A

    2012-01-01

    Delayed diagnosis of a bowel or mesenteric injury resulting in hollow viscus perforation leads to significant morbidity and mortality from hemorrhage, peritonitis, or abdominal sepsis. The timely diagnosis of bowel and mesenteric injuries requiring operative repair depends almost exclusively on their early detection by the radiologist on computed tomography examination, because the clinical signs and symptoms of these injuries are not specific and usually develop late. Therefore, the radiologist must be familiar with the often-subtle imaging findings of bowel and mesenteric injury that will allow for appropriate triage of a patient who has sustained blunt trauma to the abdomen or pelvis. 2012 Elsevier Inc. All rights reserved.

  17. Imaging and Screening of Cancer of the Small Bowel.

    PubMed

    Kim, Jin Sil; Park, Seong Ho; Hansel, Stephanie; Fletcher, Joel G

    2017-11-01

    Delayed diagnosis of small bowel cancers frequently occurs and may arise because of many factors, including low incidence of disease, difficult endoscopic access, lack of mucosal mass or abnormality, subtle radiologic features, and low index of clinical suspicion. As small bowel cancers are rare and their causes are largely unknown, routine population-based screening of asymptomatic patients to find precursor lesions or early cancers is ineffective. However, targeted screening/surveillance strategies are used in specific at-risk and symptomatic patient populations. This article reviews issues regarding early diagnosis of small bowel cancers, with focus on state-of-the-art cross-sectional imaging techniques. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Large bowel obstruction due to gallstones: an endoscopic problem?

    PubMed Central

    Waterland, Peter; Khan, Faisal Shehzaad; Durkin, Damien

    2014-01-01

    A 73-year-old man was admitted with symptoms of large bowel obstruction. An emergency CT scan revealed pneumobilia and large bowel obstruction at the level of the rectosigmoid due to a 4×4 cm impacted gallstone. Flexible sigmoidoscopy confirmed the diagnosis but initial attempts to drag the stone into the rectum failed. An endoscopic mechanical lithotripter was employed to repeatedly fracture the gallstone into smaller fragments, which were passed spontaneously the next day. The patient made a complete recovery avoiding the potential dangers of surgery. This case report discusses cholecystoenteric fistula and a novel minimally invasive treatment for large bowel obstruction due to gallstones. PMID:24390966

  19. Large bowel obstruction due to gallstones: an endoscopic problem?

    PubMed

    Waterland, Peter; Khan, Faisal Shehzaad; Durkin, Damien

    2014-01-03

    A 73-year-old man was admitted with symptoms of large bowel obstruction. An emergency CT scan revealed pneumobilia and large bowel obstruction at the level of the rectosigmoid due to a 4×4 cm impacted gallstone. Flexible sigmoidoscopy confirmed the diagnosis but initial attempts to drag the stone into the rectum failed. An endoscopic mechanical lithotripter was employed to repeatedly fracture the gallstone into smaller fragments, which were passed spontaneously the next day. The patient made a complete recovery avoiding the potential dangers of surgery. This case report discusses cholecystoenteric fistula and a novel minimally invasive treatment for large bowel obstruction due to gallstones.

  20. Fabrication of Superhydrophobic Calcium Phosphate Coating on Mg-Zn-Ca alloy and Its Corrosion Resistance

    NASA Astrophysics Data System (ADS)

    Zhang, Lashuang; Jiang, Yue; Zai, Wei; Li, Guangyu; Liu, Shaocheng; Lian, Jianshe; Jiang, Zhonghao

    2017-12-01

    A novel superhydrophobic calcium phosphate coating was prepared on a magnesium alloy substrate by a highly effective chemical conversion process and subsequent chemical modification. Different methods were employed to characterize the surface morphology and chemical composition as well as measure the wettability of the coating. It was demonstrated that the as-prepared superhydrophobic calcium phosphate coating has a typical three-level hierarchical structure consisted of micro-protrusions, submicro-lumps and nano-grains, conferring excellent superhydrophobicity with a water contact angle of 159°. The electrochemical measurements and appropriate equivalent circuit revealed that the corrosion-resistant performance of the superhydrophobic calcium phosphate coating was significantly improved as compared with that of the substrate, the corrosion potential of the superhydrophobic coating increases from -1.56 to -1.36 V, and its corrosion current density decreases from 1.29 × 10-4 to 1.3 × 10-6 A/cm2. The anti-corrosion mechanism of the superhydrophobic coating was also discussed. It can be indicated that the corrosion inhibitive properties of the coating are in accordance with its hydrophobicity, which is owing to the presence of a protective layer of air trapped in the grooves of the coating surface to isolate the underlying materials from the external environment.

  1. [A Feasibility Study of closing the small bowel with high-frequency welding device].

    PubMed

    Zhou, Huabin; Han, Shuai; Chen, Jun; Huang, Dequn; Peng, Liang; Ning, Jingxuan; Li, Zhou

    2014-12-01

    This study aimed to evaluate the feasibility and effectiveness of closing the small bowel in an ex vivo porcine model with high-frequency welding device. A total of 100 porcine small bowels were divided into two groups, and then were closed with two different methods. The fifty small bowels in experimental group were closed by the high-frequency welding device, and the other fifty small bowels in comparison group were hand-sutured. All the small bowels were subjected to leak pressure testing later on. The speed of closure and bursting pressure were compared. The 50 porcine small bowels closed by the high-frequency welding device showed a success rate of 100%. Compared with the hand-sutured group, the bursting pressures of the former were significantly lower (P<0.01) and the closing process was significantly shorter (P<0.01). The pathological changes of the closed ends mainly presented as acute thermal and pressure induced injury. Experimental results show that the high-frequency welding device has higher feasibility in closing the small bowel.

  2. Steroid Exposure, Acute Coronary Syndrome, and Inflammatory Bowel Disease: Insights into the Inflammatory Milieu

    PubMed Central

    Deaño, Roderick C.; Basnet, Sandeep; Onandia, Zurine Galvan; Gandhi, Sachin; Tawakol, Ahmed; Min, James K.; Truong, Quynh A.

    2014-01-01

    Background Steroids are anti-inflammatory agents commonly used to treat inflammatory bowel disease. Inflammation plays a critical role in the pathophysiology of both inflammatory bowel disease and acute coronary syndrome. We examined the relationship between steroid use in patients with inflammatory bowel disease and acute coronary syndrome. Methods In 177 patients with inflammatory bowel disease (mean age 67, 75% male, 44% Crohn's disease, 56% ulcerative colitis), we performed a 1:2 case-control study matched for age, sex and inflammatory bowel disease type and compared 59 patients with inflammatory bowel disease with acute coronary syndrome to 118 patients with inflammatory bowel disease without acute coronary syndrome. Steroid use was defined as current or prior exposure. Acute coronary syndrome was defined as myocardial infarction or unstable angina, confirmed by cardiac biomarkers and coronary angiography. Results In patients with inflammatory bowel disease, 34% with acute coronary syndrome had exposure to steroids versus 58% without acute coronary syndrome (p<0.01). Steroid exposure reduced the adjusted odds of acute coronary syndrome by 82% (odds ratio [OR] 0.39, 95% CI 0.20-0.74; adjusted OR 0.18, 95% CI 0.06-0.51) in patients with inflammatory bowel disease, 77% in Crohn's disease (OR 0.36, 95% CI 0.14-0.92; adjusted OR 0.23, 95% CI 0.06-0.98), and 78% in ulcerative colitis (OR 0.41, 95% CI 0.16-1.04; adjusted OR 0.22, 95% CI 0.06-0.90). There was no association between other inflammatory bowel disease medications and acute coronary syndrome. Conclusions In patients with inflammatory bowel disease, steroid use significantly reduces the odds of acute coronary syndrome. These findings provide further mechanistic insight into the inflammatory processes involved in inflammatory bowel disease and acute coronary syndrome. PMID:25446295

  3. 2-Litre polyethylene glycol-citrate-simethicone plus bisacodyl versus 4-litre polyethylene glycol as preparation for colonoscopy in chronic constipation.

    PubMed

    Parente, Fabrizio; Vailati, Cristian; Bargiggia, Stefano; Manes, Gianpiero; Fontana, Paola; Masci, Enzo; Arena, Monica; Spinzi, Giancarlo; Baccarin, Alessandra; Mazzoleni, Giorgia; Testoni, Pier Alberto

    2015-10-01

    Chronic constipation is a risk factor of inadequate bowel preparation for colonoscopy; however, no large clinical trials have been performed in this subgroup of patients. To compare bowel cleansing efficacy, tolerability and acceptability of 2-L polyethylene-glycol-citrate-simethicone (PEG-CS) plus 2-day bisacodyl (reinforced regimen) vs. 4-L PEG in patients with chronic constipation undergoing colonoscopy. Randomized, observer-blind, parallel group study. Adult outpatients undergoing colonoscopy were randomly allocated to 2-L PEG-CS/bisacodyl or 4-L PEG, taken as split regimens before colonoscopy. Quality of bowel preparation was assessed by the Ottawa Bowel Cleansing Scale (OBCS). The amount of foam/bubble interfering with colonic visualization was also measured. 400 patients were enrolled. There was no significant difference in successful cleansing (OBCS score ≤6): 80.2% in the 2-L PEG-CS/bisacodyl vs. 81.4% in the 4-L PEG group. Significantly more patients taking 2L PEG-CS/bisacodyl showed no or minimal foam/bubbles in all colonic segments (80% vs. 63%; p<0.001). 2-L PEG-CS/bisacodyl was significantly more acceptable for ease of administration (p<0.001), willingness to repeat (p<0.001) and showed better compliance (p=0.002). Split 2-L PEG-CS plus bisacodyl was not superior to split 4-L PEG for colonoscopy bowel cleansing in patients with chronic constipation; however, it performed better than the standard regimen in terms of colonic mucosa visualization, patient acceptance and compliance. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. MRI in patients with inflammatory bowel disease

    PubMed Central

    Gee, Michael S.; Harisinghani, Mukesh G.

    2011-01-01

    Inflammatory bowel disease (IBD) affects approximately 1.4 million people in North America and, because of its typical early age of onset and episodic disease course, IBD patients often undergo numerous imaging studies over the course of their lifetimes. CT has become the standard imaging modality for assessment of IBD patients because of its widespread availability, rapid image acquisition, and ability to evaluate intraluminal and extraluminal disease. However, repetitive CT imaging has been associated with a significant ionizing radiation risk to patients, making MRI an appealing alternative IBD imaging modality. Pelvic MRI is currently the imaging gold standard for detecting perianal disease, while recent studies indicate that MRI bowel-directed techniques (enteroclysis, enterography, colonography) can accurately evaluate bowel inflammation in IBD. With recent technical innovations leading to faster and higher resolution body MRI, the role of MRI in IBD evaluation is likely to continue to expand. Future applications include surveillance imaging, detection of mural fibrosis, and early assessment of therapy response. PMID:21512607

  5. Multidetector CT of Surgically Proven Blunt Bowel and Mesenteric Injury.

    PubMed

    Bates, David D B; Wasserman, Michael; Malek, Anita; Gorantla, Varun; Anderson, Stephan W; Soto, Jorge A; LeBedis, Christina A

    2017-01-01

    Blunt traumatic injury is one of the leading causes of morbidity and mortality in the United States. Unintentional injury represents the leading cause of death in the United States for all persons between the ages of 1 and 44 years. In the setting of blunt abdominal trauma, the reported rate of occurrence of bowel and mesenteric injuries ranges from 1% to 5%. Despite the relatively low rate of blunt bowel and mesenteric injury in patients with abdominal and pelvic trauma, delays in diagnosis are associated with increased rates of sepsis, a prolonged course in the intensive care unit, and increased mortality. During the past 2 decades, as multidetector computed tomography (CT) has emerged as an essential tool in emergency radiology, several direct and indirect imaging features have been identified that are associated with blunt bowel and mesenteric injury. The imaging findings in cases of blunt bowel and mesenteric injury can be subtle and may be seen in the setting of multiple complex injuries, such as multiple solid-organ injuries and spinal fractures. Familiarity with the various imaging features of blunt bowel and mesenteric injury, as well as an understanding of their clinical importance with regard to the care of the patient, is essential to making a timely diagnosis. Once radiologists are familiar with the spectrum of findings of blunt bowel and mesenteric injury, they will be able to make timely diagnoses that will lead to improved patient outcomes. © RSNA, 2017.

  6. Nutritional impact of inflammatory bowel diseases on children and adolescents☆

    PubMed Central

    dos Santos, Gilton Marques; Silva, Luciana Rodrigues; Santana, Genoile Oliveira

    2014-01-01

    OBJECTIVE: To perform a sistematiy review of the literature about the nutritional impact of inflammatory bowel diseases in children and adolescents. DATA SOURCES: A systematic review was performed using PubMed/MEDLINE, LILACS and SciELO databases, with inclusion of articles in Portuguese and in English with original data, that analyzed nutritional aspects of inflammatory bowel diseases in children and adolescents. The initial search used the terms "inflammatory bowel diseases" and "children" or "adolescents" and "nutritional evaluation" or "nutrition deficiency". The selection of studies was initially performed by reading the titles and abstracts. Review studies and those withouth data for pediatric patients were excluded. Subsequently, the full reading of the articles considered relevant was performed. RESULTS: 237 studies were identified, and 12 of them were selected according to the inclusion criteria. None of them was performed in South America. During the analysis of the studies, it was observed that nutritional characteristics of patients with inflammatory bowel disease may be altered; the main reports were related to malnutrition, growth stunting, delayed puberty and vitamin D deficiency. CONCLUSION: There are nutritional consequences of inflammatory bowel diseases in children and adolescents, mainly growth stunting, slower pubertal development, underweight and vitamin deficiencies. Nutritional impairments were more significant in patients with Crohn's disease; overweight and obesity were more common in patients with ulcerative rectocolitis. A detailed nutritional assessment should be performed periodically in children and adolescents with inflammatory bowel disease. PMID:25511006

  7. The expanding universe of inflammatory bowel disease genetics.

    PubMed

    Achkar, Jean-Paul; Duerr, Richard

    2008-07-01

    Genetic factors play an important role in the pathogenesis of inflammatory bowel disease. In this review, we will provide an update on the rapid advances in the discovery of inflammatory bowel disease, primarily Crohn's disease, associated genes. Seven recently published Crohn's disease genome-wide association studies have confirmed prior findings related to the nucleotide-binding oligomerization domain 2 (NOD2) gene and the IBD5 locus. In addition, 10 novel loci have been identified and well replicated. Several promising associations between Crohn's disease and gene variants have been identified and replicated, the two most widely replicated being variants in the IL23R and ATG16L1 genes. These findings highlight and further support the importance of the immune system and its interactions with the intestinal microflora in the pathogenesis of inflammatory bowel disease.

  8. Inositol phosphates in the environment.

    PubMed Central

    Turner, Benjamin L; Papházy, Michael J; Haygarth, Philip M; McKelvie, Ian D

    2002-01-01

    The inositol phosphates are a group of organic phosphorus compounds found widely in the natural environment, but that represent the greatest gap in our understanding of the global phosphorus cycle. They exist as inositols in various states of phosphorylation (bound to between one and six phosphate groups) and isomeric forms (e.g. myo, D-chiro, scyllo, neo), although myo-inositol hexakisphosphate is by far the most prevalent form in nature. In terrestrial environments, inositol phosphates are principally derived from plants and accumulate in soils to become the dominant class of organic phosphorus compounds. Inositol phosphates are also present in large amounts in aquatic environments, where they may contribute to eutrophication. Despite the prevalence of inositol phosphates in the environment, their cycling, mobility and bioavailability are poorly understood. This is largely related to analytical difficulties associated with the extraction, separation and detection of inositol phosphates in environmental samples. This review summarizes the current knowledge of inositol phosphates in the environment and the analytical techniques currently available for their detection in environmental samples. Recent advances in technology, such as the development of suitable chromatographic and capillary electrophoresis separation techniques, should help to elucidate some of the more pertinent questions regarding inositol phosphates in the natural environment. PMID:12028785

  9. Constructing a novel hierarchical 3D flower-like nano/micro titanium phosphate with efficient hydrogen evolution from water splitting

    NASA Astrophysics Data System (ADS)

    Guo, Si-yao; Han, Song

    2014-12-01

    A novel nano/micro hierarchical structured titanium phosphate with unique 3D flower-like morphology has been prepared by a simple hydrothermal method without adding any surfactants. The shape of the titanium phosphate could be controlled by simply adjusting the concentration of phosphoric acid. The 3D flower-like titanium phosphate with diameter of 2-3 μm is characterized by the assembly of numerous porous and connected lamella structures. Interestingly, this novel hierarchical mesoporous 3D flower-like titanium exhibits enhanced hydrogen evolution from water splitting under xenon lamp irradiation in the presence of methanol as the sacrificial reagent, which is also the first example of 3D flower-like titanium phosphate with high photocatalytic activity for water splitting. Since the use of titanium phosphate as a photocatalyst has been mostly neglected up to now, this low-cost, simple procedure and large-scale yield of 3D nano/micro structure titanium phosphate could be expected to be applicable in the synthesis of controlled, reproducible and robust photocatalytic systems.

  10. Phosphate Ion Exchange Resin Used in the Liquid Preservation of Baboon Red Blood Cells.

    DTIC Science & Technology

    1982-06-08

    absence of resin. The addition of a phosphate anion exchange resin to the CPD anticoagulant provided better maintenance of red cell 23 DPG and P50 levels ...than red blood cells S.prepared from blood without resin. Red blood cell ATP levels and 24-hour post- transfusion survival values were similar whether or...coagulant provided better maintenance of red cell 2,3 DPG and P50 levels during storage of whole blood at 4 C, and red blood cells prepared from whole

  11. Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids: Effect of Bowel Interposition on Procedure Feasibility and a Unique Bowel Displacement Technique.

    PubMed

    Kim, Young-Sun; Lim, Hyo Keun; Rhim, Hyunchul

    2016-01-01

    To evaluate the effect of bowel interposition on assessing procedure feasibility, and the usefulness and limiting conditions of bowel displacement techniques in magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids. Institutional review board approved this study. A total of 375 screening MR exams and 206 MR-HIFU ablations for symptomatic uterine fibroids performed between August 2010 and March 2015 were retrospectively analyzed. The effect of bowel interposition on procedure feasibility was assessed by comparing pass rates in periods before and after adopting a unique bowel displacement technique (bladder filling, rectal filling and subsequent bladder emptying; BRB maneuver). Risk factors for BRB failure were evaluated using logistic regression analysis. Overall pass rates of pre- and post-BRB periods were 59.0% (98/166) and 71.7% (150/209), and in bowel-interposed cases they were 14.6% (7/48) and 76.4% (55/72), respectively. BRB maneuver was technically successful in 81.7% (49/60). Through-the-bladder sonication was effective in eight of eleven BRB failure cases, thus MR-HIFU could be initiated in 95.0% (57/60). A small uterus on treatment day was the only significant risk factor for BRB failure (B = 0.111, P = 0.017). The BRB maneuver greatly reduces the fraction of patients deemed ineligible for MR-HIFU ablation of uterine fibroids due to interposed bowels, although care is needed when the uterus is small.

  12. Nd- And Er-Doped Phosphate Glass For Fiber Laser.

    NASA Astrophysics Data System (ADS)

    Yamashita, Toshiharu T.

    1990-02-01

    Laser fibers prepared from Nd- and Er-doped phosphate glass possessing a large stimulated emission cross section have been investigated both in a single fiber and in a fiber bundle. In the single fiber, continuous wave oscillations were successfully obtained at 1.054 p.m and 1.366 µm on a high Nd-doped single-mode fiber of 10 mm in length and also at 1.535 pm in a Er-doped single-mode fiber, sensitized by Nd, Yb. Especially, a low threshold of 1 mw and a high slope-efficiency of 50% were achieved in 1.054 pm laser oscillation on a Nd-doped fiber, end-pumped with a laser diode. A fiber bundle of phosphate glass doped with 8 wt% Nd2O3 yielded an average output power of 100 W at 50 pps where the bundle was 4.6 mm in diameter and was side-pumped with flash lamps.

  13. [Neurological complications of inflammatory bowel diseases].

    PubMed

    Cieplik, N; Stangel, M; Bachmann, O

    2013-02-01

    Inflammatory bowel diseases, such as Crohn's disease, ulcerative colitis, autoantibody driven celiac disease and infectious Whipple's disease can all be associated with neurological symptoms. The neurological manifestation may occur even before the gastrointestinal symptoms or the enteropathic symptoms can even be absent as in celiac disease. These diseases can be caused by malresorption and lack of vitamins due to enteral inflammation as well as (auto-)immunological mechanisms and drug-associated side effects. Thus, inflammatory bowel diseases have to be considered in the differential diagnosis. In this review the most common neurological manifestations of these diseases will be described as well as the diagnostic approach.

  14. Medical and psychological aspects of irritable bowel syndrome.

    PubMed

    Kim, E C; Dundon, M

    1998-01-01

    Irritable bowel syndrome is a disease process commonly encountered by primary care providers. Although the cause of this illness is unknown, much is known about the pathophysiology and strong psychosocial influences. Medical practitioners often are aware of the medical aspects of managing irritable bowel syndrome but are not familiar with specific psychologic options. Long-term care of these patients may be aided by collaboration with mental health professionals.

  15. Nephrolithiasis as a common urinary system manifestation of inflammatory bowel diseases; a clinical review and meta-analysis.

    PubMed

    Ganji-Arjenaki, Mahboube; Nasri, Hamid; Rafieian-Kopaei, Mahmoud

    2017-07-01

    The extra-intestinal manifestations of inflammatory bowel disease (IBD) are common and involve other organs or systems for example; urinary system. For this review, we used a variety of sources by searching through Web of Science, PubMed, EMBASE, Scopus and directory of open access journals (DOAJ). Urinary complications may occur in up to 22% of patients and nephrolithiasis or renal/kidney stones have been suggested to be a common manifestation of disease in forms of uric acid, calcium phosphate or calcium oxalate. We performed a meta-analysis on five clinical trials and reported that correlation between IBD and formation of stone in renal system is positive and significant (Fix-effect model; CI: 95%, P <0.001, and randomeffect model; CI: 95%, P = 0.03). Based on the reports of the clinical trials, calcium oxalate is more prevalent in Crohn's disease (CD) than in ulcerative colitis (UC).

  16. Oral peptide specific egg antibody to intestinal sodium-dependent phosphate co-transporter-2b is effective at altering phosphate transport in vitro and in vivo.

    PubMed

    Bobeck, Elizabeth A; Hellestad, Erica M; Sand, Jordan M; Piccione, Michelle L; Bishop, Jeff W; Helvig, Christian; Petkovich, Martin; Cook, Mark E

    2015-06-01

    Hyperimmunized hens are an effective means of generating large quantities of antigen specific egg antibodies that have use as oral supplements. In this study, we attempted to create a peptide specific antibody that produced outcomes similar to those of the human pharmaceutical, sevelamer HCl, used in the treatment of hyperphosphatemia (a sequela of chronic renal disease). Egg antibodies were generated against 8 different human intestinal sodium-dependent phosphate cotransporter 2b (NaPi2b) peptides, and hNaPi2b peptide egg antibodies were screened for their ability to inhibit phosphate transport in human intestinal Caco-2 cell line. Antibody produced against human peptide sequence TSPSLCWT (anti-h16) was specific for its peptide sequence, and significantly reduced phosphate transport in human Caco-2 cells to 25.3±11.5% of control nonspecific antibody, when compared to nicotinamide, a known inhibitor of phosphate transport (P≤0.05). Antibody was then produced against the mouse-specific peptide h16 counterpart (mouse sequence TSPSYCWT, anti-m16) for further analysis in a murine model. When anti-m16 was fed to mice (1% of diet as dried egg yolk powder), egg yolk immunoglobulin (IgY) was detected using immunohistochemical staining in mouse ileum, and egg anti-m16 IgY colocalized with a commercial goat anti-NaPi2b antibody. The effectiveness of anti-m16 egg antibody in reducing serum phosphate, when compared to sevelamer HCl, was determined in a mouse feeding study. Serum phosphate was reduced 18% (P<0.02) in mice fed anti-m16 (1% as dried egg yolk powder) and 30% (P<0.0001) in mice fed sevelamer HCl (1% of diet) when compared to mice fed nonspecific egg immunoglobulin. The methods described and the findings reported show that oral egg antibodies are useful and easy to prepare reagents for the study and possible treatment of select diseases. © 2015 Poultry Science Association Inc.

  17. Characterization of Symptoms in Irritable Bowel Syndrome with Mixed Bowel Habit Pattern

    PubMed Central

    Su, Andrew; Shih, Wendy; Presson, Angela P.; Chang, Lin

    2013-01-01

    Background Irritable bowel syndrome (IBS) with mixed bowel habits (IBS-M) is a heterogeneous subtype with varying symptoms of constipation and diarrhea, and has not been well characterized. We aimed to characterize gastrointestinal (GI) and non-GI symptoms in IBS-M patients from a U.S. community, and to compare them with IBS with constipation (IBS-C) and diarrhea (IBS-D). Methods Subjects answering community advertisements and meeting Rome III criteria for IBS completed symptom questionnaires. Key Results Of the initial 289 IBS patients identified, one-third (n=51, 32.5%) who met Rome III criteria for IBS-M endorsed having either loose stools or hard stools due to medication. These patients had more severe symptoms and longer duration of flares compared to the rest of the IBS-M group (p = 0.014, p = 0.005). Excluding IBS-M patients with medication-related extremes in stool form who could not be reclassified by medical history, 247 IBS patients were assessed. IBS-M was the most common (44.1%), followed by IBS-C (27.9%), IBS-D (26.3%), and IBS-U (unsubtyped, 1.6%). IBS-M shared symptoms with both IBS-C and IBS-D (p-value range: <0.001–0.002). IBS-M patients reported most bothersome symptoms more similarly to IBS-D, with the most common being irregular bowel habits (27.5%), bloating (26.6%), and abdominal pain (20.2%). There were no differences in non-GI symptoms between subtypes. Conclusions & Inferences IBS-M is a heterogeneous symptom group and thus requires that subclassification criteria be better defined. Use of laxative/anti-diarrheal medications adds to the diagnostic complexity in a potentially more severe subset of IBS-M and should be assessed for accurate subclassification. PMID:23991913

  18. Bowel ultrasound imaging in patients with cystic fibrosis: Relationship with clinical symptoms and CFTR genotype.

    PubMed

    Fraquelli, Mirella; Baccarin, Alessandra; Corti, Fabiola; Conti, Clara Benedetta; Russo, Maria Chiara; Della Valle, Serena; Pozzi, Roberta; Cressoni, Massimo; Conte, Dario; Colombo, Carla

    2016-03-01

    Ultrasound imaging is used to assess bowel abnormalities in gastrointestinal diseases. We aimed to assess the rate of predefined bowel ultrasound signs and their relationship with gastrointestinal symptoms and the cystic fibrosis transmembrane conductance regulator (CFTR) genotype in cystic fibrosis patients in regular follow-up. Prospective study of 70 consecutive patients with cystic fibrosis and 45 controls who underwent abdominal ultrasound; pertinent findings were related to gastrointestinal symptoms and, in cystic fibrosis patients, to pancreatic status, malabsorption degree, lipase intake, CFTR genotype (classified as severe or mild against functional class of CFTR mutations). 96% patients showed at least one abnormal bowel ultrasound sign. Most frequent signs were lymph node enlargement (64%), bowel loop dilatation (55%), thick corpuscular intraluminal content (49%), bowel wall hypervascularization (26%), thickened bowel wall (22%) and intussusception (17%). Patients with recurrent abdominal pain showed more bowel wall hypervascularization than patients without recurrent pain (47% vs. 19%, respectively; p = 0.02) and intussusception (58% vs. 17%, respectively; p < 0.01). Genotype was not associated to specific bowel ultrasound signs. Patients with bowel loop intussusception showed greater lipase intake than those without intussusception (8.118 ± 2.083 vs. 5.994 ± 4.187, respectively; p < 0.01). Cystic fibrosis patients present a higher rate of bowel ultrasound abnormalities than controls. Bowel ultrasound abnormalities are associated with abdominal symptoms. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  19. Small Bowel Dose Parameters Predicting Grade ≥3 Acute Toxicity in Rectal Cancer Patients Treated With Neoadjuvant Chemoradiation: An Independent Validation Study Comparing Peritoneal Space Versus Small Bowel Loop Contouring Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banerjee, Robyn, E-mail: robynbanerjee@gmail.com; Chakraborty, Santam; Nygren, Ian

    Purpose: To determine whether volumes based on contours of the peritoneal space can be used instead of individual small bowel loops to predict for grade ≥3 acute small bowel toxicity in patients with rectal cancer treated with neoadjuvant chemoradiation therapy. Methods and Materials: A standardized contouring method was developed for the peritoneal space and retrospectively applied to the radiation treatment plans of 67 patients treated with neoadjuvant chemoradiation therapy for rectal cancer. Dose-volume histogram (DVH) data were extracted and analyzed against patient toxicity. Receiver operating characteristic analysis and logistic regression were carried out for both contouring methods. Results: Grade ≥3more » small bowel toxicity occurred in 16% (11/67) of patients in the study. A highly significant dose-volume relationship between small bowel irradiation and acute small bowel toxicity was supported by the use of both small bowel loop and peritoneal space contouring techniques. Receiver operating characteristic analysis demonstrated that, for both contouring methods, the greatest sensitivity for predicting toxicity was associated with the volume receiving between 15 and 25 Gy. Conclusion: DVH analysis of peritoneal space volumes accurately predicts grade ≥3 small bowel toxicity in patients with rectal cancer receiving neoadjuvant chemoradiation therapy, suggesting that the contours of the peritoneal space provide a reasonable surrogate for the contours of individual small bowel loops. The study finds that a small bowel V15 less than 275 cc and a peritoneal space V15 less than 830 cc are associated with a less than 10% risk of grade ≥3 acute toxicity.« less

  20. Mesoscale crystallization of calcium phosphate nanostructures in protein (casein) micelles

    NASA Astrophysics Data System (ADS)

    Thachepan, Surachai; Li, Mei; Mann, Stephen

    2010-11-01

    Aqueous micelles of the multi-protein calcium phosphate complex, casein, were treated at 60 °C and pH 7 over several months. Although partial dissociation of the micelles into 12 nm sized amorphous calcium phosphate (ACP)/protein nanoparticles occurred within a period of 14 days, crystallization of the ACP nanoclusters into bundles of hydroxyapatite (HAP) nanofilaments was not observed until after 12 weeks. The HAP nanofilaments were formed specifically within the partially disrupted protein micelles suggesting a micelle-mediated pathway of mesoscale crystallization. Similar experiments using ACP-containing synthetic micelles prepared from β-casein protein alone indicated that co-aligned bundles of HAP nanofilaments were produced within the protein micelle interior after 24 hours at temperatures as low as 35 °C. The presence of Mg2+ ions in the casein micelles, as well as a possible synergistic effect associated with the multi-protein nature of the native aggregates, could account for the marked inhibition in mesoscale crystallization observed in the casein micelles compared with the single-component β-casein constructs.Aqueous micelles of the multi-protein calcium phosphate complex, casein, were treated at 60 °C and pH 7 over several months. Although partial dissociation of the micelles into 12 nm sized amorphous calcium phosphate (ACP)/protein nanoparticles occurred within a period of 14 days, crystallization of the ACP nanoclusters into bundles of hydroxyapatite (HAP) nanofilaments was not observed until after 12 weeks. The HAP nanofilaments were formed specifically within the partially disrupted protein micelles suggesting a micelle-mediated pathway of mesoscale crystallization. Similar experiments using ACP-containing synthetic micelles prepared from β-casein protein alone indicated that co-aligned bundles of HAP nanofilaments were produced within the protein micelle interior after 24 hours at temperatures as low as 35 °C. The presence of Mg2+ ions in