Science.gov

Sample records for planar bone scintigraphy

  1. Bone scintigraphy in diabetic osteoarthropathy

    SciTech Connect

    Eymontt, M.J.; Alavi, A.; Dalinka, M.K.; Kyle, G.C.

    1981-08-01

    Bone scans of patients with diabetic osteoarthropathy of the ankle and foot were characterized by a combination of diffuse and focal increased uptake, similar to that seen with hyperemia and reactive new bone formation. Scintigraphy showed more extensive abnormalities than radiography, with the scan abnormalities sometimes preceding the radiographic changes. The clinical and scintigraphic appearance of osteoarthropathy may improve following strict diabetic control and non-weight-bearing.

  2. Incidental finding of meningioma on bone scintigraphy.

    PubMed

    Thakorlal, A; Wong, D C; Anderson, R J

    2005-06-01

    An incidental finding of an intracranial posterior fossa meningioma detected by bone scintigraphy is presented. Most of the published literature on the diagnosis of meningioma is on the use of CT and MRI. There is limited published literature on the detection of meningioma with bone scintigraphy. PMID:15932468

  3. Neonatal osteomyelitis examined by bone scintigraphy

    SciTech Connect

    Bressler, E.L.; Conway, J.J.; Weiss, S.C.

    1984-09-01

    Thirty-three infants less than six weeks of age and suspected of having osteomyelitis were examined by bone scintigraphy. Each of the 25 sites of proved osteomyelitis in 15 individuals demonstrated abnormal radionuclide localization. Ten additional scintigraphically positive but radiographically normal sites were detected. Optimal quality scintigrams of the growth plate complex and osteomyelitis in neonates appeared similar to those in older children. All neonates suspected of having osteomyelitis should be studied with bone scintigraphy following initial radiographs.

  4. Bone scintigraphy in the diagnosis of mastoiditis

    SciTech Connect

    Floyd, J.L.; Goodman, E.L.

    1981-07-01

    Bone scintigraphy has proven utility in the early diagnosis of osteomyelitis, but the authors were unable to find any report of its specific application to mastoiditis. Three cases of mastoiditis are presented in which the bone scan findings predicted the histopathologic findings.

  5. Radionuclide bone scintigraphy in pediatric orthopedics

    SciTech Connect

    Conway, J.J.

    1986-12-01

    Radionuclide bone scintigraphy is highly sensitive and specific for diagnosing the musculoskeletal disorders of childhood. Conditions such as neonatal osteomyelitis, septic arthritis, diskitis of childhood, Legg-Calve-Perthes disease, the osteochondroses, the toddler's fracture, sports injuries, spondylolysis, myositis ossificians, and reflex sympathetic dystrophy are readily defined. High-quality state-of-the-art scintigraphy is essential in infants and young children. 64 references.

  6. Femoroacetabular impingement mimicking avascular osteonecrosis on bone scintigraphy

    PubMed Central

    Suarez, Juan Pablo; Domínguez, María Luz; Nogareda, Zulema; Gómez, María Asunción; Muñoz, Jose

    2016-01-01

    Femoroacetabular impingement (FAI) is a structural abnormality of proximal femur and/or acetabulum. It has been recently described, and there are limited reports in nuclear medicine literature because bone scintigraphy is not listed in its diagnostic protocol, but it should be included on differential diagnosis when evaluating patients, with hip-related symptoms because it may be misinterpreted as degenerative changes or avascular necrosis, and its early treatment avoid progression to osteoarthritis. We describe the case of a male who suffered from hip pain. Bone planar scintigraphic appearance mimicked avascular necrosis, but single photon emission computed tomography (CT) imaging and CT examination confirmed the diagnosis of FAI. PMID:27095871

  7. Findings of Bone Scintigraphy After Leech Theraphy

    PubMed Central

    Özyurt, Sinem; Koca, Gökhan; Demirel, Koray; Baskın, Aylin; Korkmaz, Meliha

    2014-01-01

    In this case report, we present a 70 year old female patient who had recieved Leech therapy (hirudotherapy) on her leg without informing referring physician. In dynamic bone scintigraphy there was increased perfusion and hyperemia in her left ankle and leg, also in late static images moderate increased uptake was seen in soft tissue region and at the fracture site of ankle. We learned that she had Leech therapy applied on her leg, which could explain the increased perfusion and hyperemia in dynamic and blood pool phases of bone scintigraphy because of Leech therapy’s dilatory effects on superficial veins. Leech therapy may lead to an increase in perfusion and hyperemia in blood pool phase of bone scintigraphy, which may cause confusion in differential diagnosis. To our best knowledge this report is the first case that shows the scintigraphic findigs after Leech therapy. Conflict of interest:None declared. PMID:24653932

  8. Quantitative planar imaging in renal scintigraphy

    NASA Astrophysics Data System (ADS)

    Lárraga, J. M.; Martínez-Dávalos, A.; Martínez-Duncker, C.; Rodríguez, R. Herrera

    2002-08-01

    In this work we show the results of the implementation of the double energy window method (DEW) to correct for scatter and geometric mean of opposite image to correct for attenuation of radiation within the patient for absolute quantification of radiotracer in renal scintigraphy studies. We show that DEW method subestimates the scatter radiation within main energy window and that result in a 11% of maximun error for the determination of true activity of a renal kidney phantom. Moreover, in order to avoid transmission scans of patients we perform a Monte Carlo simulation (MC) for the determination of scatter component of the main energy window. The results of the MC simulation was validated with experimental data of emission studies.

  9. Bone scintigraphy in slipped capital femoral epiphysis

    SciTech Connect

    Gelfand, M.J.; Strife, J.L.; Graham, E.J.; Crawford, A.H.

    1983-12-01

    Tc-/sub 99m/ diphosphonate bone scans were performed on 11 children with slipped capital femoral epiphysis. On pinhole hip images, seven hips in seven patients had increased radionuclide uptake in the physis and adjacent proximal femoral metaphysis where the slip had occurred. Three hips in three patients had decreased radionuclide uptake in the femoral head on the side of the slipped epiphysis, indicating compromise of the femoral head blood supply. Three or more months following internal fixation, three children had scintigraphy that showed loss of the usual focal uptake in the physis and adjacent proximal femoral metaphysis. Bone scintigraphy in pediatric patients with slipped capital femoral epiphysis is valuable in defining the metabolic status of the femoral head. Absence of radiopharmaceutical uptake in the affected femoral head indicates that the femoral head is at risk for development of radiographic changes associated with aseptic necrosis.

  10. Bone scintigraphy in fluoride treated osteoporosis

    SciTech Connect

    Froelich, J.W.; Kleerekoper, M.; Parker, D.A.

    1985-05-01

    Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. They also demonstrate the utility of serial quantitative bone scintigraphy in assessing osteoporotic patients with vertebral compression fractures.

  11. Unsuspected pregnancy during bone scintigraphy

    SciTech Connect

    Oates, E.; Ramberg, K.; Becker, J.L. )

    1990-06-01

    Despite careful screening efforts to avoid it, nuclear medicine studies are unintentionally performed on pregnant patients. Three-phase bone scanning is a common procedure performed in women of child-bearing age. Unsuspected pregnancies have been discovered on the flow and early view of the pelvis. The authors present a case of a pregnant girl, aged 15, who had a bone scan. They explain how this occurred and how they plan to prevent a recurrence. Dosimetry for the fetus also is considered.

  12. Evaluation of osseous metastasis in bone scintigraphy.

    PubMed

    Davila, Diego; Antoniou, Alexander; Chaudhry, Muhammad A

    2015-01-01

    Bone scintigraphy (BS) is an imaging tool commonly used for screening patients with cancer, especially those with high prevalence of osseous metastases including the breast, prostate, lung, thyroid, and kidney, which account for 80% of osseous metastasis. BS has been shown to be of value in the initial and subsequent treatment strategy of various malignancies. The purpose of this article is to evaluate the technical and imaging aspects of BS and to examine the present research into improved detection of osseous metastasis. PMID:25475375

  13. Bone scintigraphy and the added value of SPECT (single photon emission tomography) in detecting skeletal lesions.

    PubMed

    Savelli, G; Maffioli, L; Maccauro, M; De Deckere, E; Bombardieri, E

    2001-03-01

    Skeletal metastases are one of the major clinical problems for the oncologist. Over the last several decades bone scintigraphy has been used extensively in detecting bone involvement since it can provide information about disease location, prognosis and the effectiveness of treatment. Bone scan offers the advantage of total body examination, and images bone lesions earlier than other techniques. In this paper the main clinical problems related to the most common applications of bone scan in breast, prostate, lung cancer and other tumours are discussed. The experience carried out at the National Cancer Institute of Milan by using bone SPECT to detect single bone metastases is reported. One hundred and eighteen patients with bone metastases (from different tumour types: breast, lung, prostate, lymphomas, etc.) were studied by planar scintigraphy, SPECT and other radiological modalities (CT, MRI or X-rays). The overall performances of bone SPECT were sensitivity: 90.5% (19/21), specificity 92.8% (90/97), positive predictive value 73% (19/26), negative predictive value 97.8% (90/92), accuracy 92.4% (109/118). Considering breast cancer, the most frequent pathology in our series, and the lumbar spinal tract, the most common skeletal segment involved, the figures of merit of SPECT were: sensitivity 100% (4/4), specificity 95.3% (41/43), positive predictive value 66.7% (4/6), negative predictive value 100% (41/41), accuracy 95.7% (45/47). In conclusion bone SPECT showed very good performances, in particular improving the predictive value of planar scan in the diagnosis of vertebral metastases. PMID:11456373

  14. [Bone scintigraphy following cryodevitalization of the mandible].

    PubMed

    Döge, H; Eckelt, U; Heber, G; Nelz, P

    1985-01-01

    A tumor of the mandible can be destroyed successfully by cryogenic devitalisation. The revitalisation process was observed in 6 miniature swines by means of nuclear medical bone exploration. The bone metabolism decreased clearly postoperatively, and indeed laterally more than lingually. An increased blood flow and bone metabolism was recognized as an expression of the repair process at the border to the healthy bone after 7 days, later also lingually whereas no reaction was found laterally. The extent of the devitalised bone was 0.5-1.0 cm bigger than the cryosurgical part. PMID:4002765

  15. Bone scintigraphy of hip joint effusions in children

    SciTech Connect

    Kloiber, R.; Pavlosky, W.; Portner, O.; Gartke, K.

    1983-05-01

    Thirty-eight children with hip pain of acute onset were studied by bone scintigraphy. Nine patients had diminished radiotracer deposition involving the entire proximal femoral ossification center. This could be related to infarction or compression of blood supply by a tense joint effusion. Eight of these patients had joint aspiration confirming the presence of an effusion. Five patients had follow-up studies after aspiration, and femoral-head uptake reverted to normal in all but one which subsequently proved to be infarcted. A photopenic zone was seen on blood pool images in 10 patients, many of whom were also aspirated of fluid. Bone scintigraphy is useful in the diagnosis of joint effusions and can give information as to the state of perfusion of the femoral head. Follow-up studies after aspiration can differentiate infarction from reversible ischemia.

  16. Detection of Sentinel Lymph Nodes in Gynecologic Tumours by Planar Scintigraphy and SPECT/CT

    PubMed Central

    Kraft, Otakar; Havel, Martin

    2012-01-01

    Objective: Assess the role of planar lymphoscintigraphy and fusion imaging of SPECT/CT in sentinel lymph node (SLN) detection in patients with gynecologic tumours. Material and Methods: Planar scintigraphy and hybrid modality SPECT/CT were performed in 64 consecutive women with gynecologic tumours (mean age 53.6 with range 30-77 years): 36 pts with cervical cancer (Group A), 21 pts with endometrial cancer (Group B), 7 pts with vulvar carcinoma (Group C). Planar and SPECT/CT images were interpreted separately by two nuclear medicine physicians. Efficacy of these two techniques to image SLN were compared. Results: Planar scintigraphy did not image SLN in 7 patients (10.9%), SPECT/CT was negative in 4 patients (6.3%). In 35 (54.7%) patients the number of SLNs captured on SPECT/CT was higher than on planar imaging. Differences in detection of SLN between planar and SPECT/CT imaging in the group of all 64 patients are statistically significant (p<0.05). Three foci of uptake (1.7% from totally visible 177 foci on planar images) in 2 patients interpreted on planar images as hot LNs were found to be false positive non-nodal sites of uptake when further assessed on SPECT/CT. SPECT/CT showed the exact anatomical location of all visualised sentinel nodes. Conclusion: In some patients with gynecologic cancers SPECT/CT improves detection of sentinel lymph nodes. It can image nodes not visible on planar scintigrams, exclude false positive uptake and exactly localise pelvic and paraaortal SLNs. It improves anatomic localization of SLNs. Conflict of interest:None declared. PMID:23486989

  17. [Dw-MRI and bone scintigraphy in monitoring radio-therapy response in bone metastases].

    PubMed

    Raucci, Antonio; Gatta, Gianluca; Cuccurullo, Vincenzo

    2012-11-01

    Bone is one of the most common sites of metastatic spread of malignancy, with possible deleterious effects including pain, hypercalcemia, and pathologic fracture. External beam radiotherapy (EBRT) remains the mainstay for treatment of painful bone metastases. Diffusion-weighted MRI (DW-MRI) has been described as an efficient method to differentiate good and poor responders to radiotherapy in bone metastases patients. The addition of DWI to conventional whole-body MRI sequences enhanced lesion conspicuity and improved diagnostic accuracy. We evaluate bone metastases patients with bone scintigraphy and DW-MRI. With technical optimization, whole-body MRI with DWI, as a nonionizing imaging modality, may potentially be useful as an alternative method to bone scintigraphy in the management of bone metastases. PMID:23096728

  18. Prognostic significance of normal quantitative planar thallium-201 stress scintigraphy in patients with chest pain

    SciTech Connect

    Wackers, F.J.; Russo, D.J.; Russo, D.; Clements, J.P.

    1985-07-01

    The prognostic significance of normal quantitative planar thallium-201 stress scintigraphy was evaluated in patients with a chest pain syndrome. The prevalence of cardiac events during follow-up was related to the pretest (that is, before stress scintigraphy) likelihood of coronary artery disease determined on the basis of symptoms, age, sex and stress electrocardiography. In a consecutive series of 344 patients who had adequate thallium-201 stress scintigrams, 95 had unequivocally normal studies by quantitative analysis. The pretest likelihood of coronary artery disease in the 95 patients had a bimodal distribution. During a mean follow-up period of 22 +/- 3 months, no patient died. Three patients (3%) had a cardiac event: two of these patients (pretest likelihood of coronary artery disease 54 and 94%) had a nonfatal myocardial infarction 8 and 22 months, respectively, after stress scintigraphy, and one patient (pretest likelihood 98%) underwent percutaneous transluminal coronary angioplasty 16 months after stress scintigraphy for persisting anginal complaints. Three patients were lost to follow-up; all three had a low pretest likelihood of coronary artery disease. It is concluded that patients with chest pain and normal findings on quantitative thallium-201 scintigraphy have an excellent prognosis. Cardiac events are rare (infarction rate 1% per year) and occur in patients with a moderate to high pretest likelihood of coronary artery disease.

  19. Nurse exposure doses resulted from bone scintigraphy patient

    NASA Astrophysics Data System (ADS)

    Tunçman, Duygu; Kovan, Bilal; Poyraz, Leyla; ćapali, Veli; Demir, Bayram; Türkmen, Cüneyt

    2016-03-01

    Bone scintigraphy is used for displaying the radiologic undiagnosed bone lesions in nuclear medicine. It's general indications are researching bone metastases, detection of radiographically occult fractures, staging and follow-up in primary bone tumors, diagnosis of paget's disease, investigation of loosening and infection in orthopedic implants. It is applied with using 99mTc labeled radiopharmaceuticals (e.g 99m Tc MDP,99mTc HEDP and 99mTc HMDP). 20 -25 mCi IV radiotracer was injected into vein and radiotracer emits gamma radiation. Patient waits in isolated room for about 3 hours then a gamma camera scans radiation area and creates an image. When some patient's situation is not good, patients are hospitalized until the scanning because of patients' close contact care need. In this study, measurements were taken from ten patients using Geiger Muller counter. After these measurements, we calculated nurse's exposure radiations from patient's routine treatment, examination and emergency station.

  20. Incidental diagnosis of pregnancy on bone and gallium scintigraphy

    SciTech Connect

    Palestro, C.J.; Malat, J.; Collica, C.J.; Richman, A.H.

    1986-03-01

    Bone and gallium scintigraphy were performed as part of the diagnostic workup of a 21-yr-old woman who presented at our institution with a history of progressively worsening low back pain over a 1-wk period of time. The angiographic phase of the bone scan demonstrated a well-defined radionuclide blush within the pelvis just cephalad to the urinary bladder with persistent hyperemia noted in the blood-pool image. We attribute these findings to a uterine blush secondary to the pronounced uterine muscular hyperplasia, hyperemia, and edema that accompany pregnancy. Gallium scintigraphy demonstrated intense bilateral breast accumulation of the imaging agent in a typical doughnut pattern which is commonly found in the prelactating and lactating breast. Also demonstrated was apparent gallium accumulation in the placenta. This case is presented to emphasize the radionuclide findings that occur during pregnancy, particularly the incidental finding of radionuclide blush during the angiographic phase of a radionuclide scintigraphy which should alert the nuclear physician to the possibility of pregnancy in a woman of childbearing age.

  1. Gallium scintigraphy in bone infarction. Correlation with bone imaging

    SciTech Connect

    Armas, R.R.; Goldsmith, S.J.

    1984-01-01

    The appearance of gallium-67 images in bone infarction was studied in nine patients with sickle cell disease and correlated with the bone scan findings. Gallium uptake in acute infarction was decreased or absent with a variable bone scan uptake, and normal in healing infarcts, which showed increased uptake on bone scan. The significance of these findings is discussed.

  2. Whole body bone scintigraphy in osseous hydatosis: a case report

    PubMed Central

    Ebrahimi, Abdolali; Assadi, Majid; Saghari, Mohsen; Eftekhari, Mohammad; Gholami, Amir; Ghasemikhah, Reza; Assadi, Sakineh

    2007-01-01

    Hydatid disease is common in many parts of the world, and causes considerable health and economic loss. This disease may develop in almost any part of the body. Bone involvement is often asymptomatic, and its diagnosis is primarily based on radiographic findings. A whole body bone scan is able to show the extent and distribution of lesions. We describe an unusual case of multifocal skeletal hydatosis and also explain the clinical and diagnostic points. We hope to stimulate a high index of suspicion among clinicians to facilitate early diagnosis and to consider this disease as a differential diagnosis in cases of multiple abnormal activity in bone scintigraphy especially among people in endemic areas. PMID:17880713

  3. Subacute and chronic bone infections: Diagnosis using In-111, Ga-67 and Tc-99m MDP bone scintigraphy and radiography

    SciTech Connect

    Al-Sheikh, W.; Sfakianakis, G.N.; Mnaymneh, W.; Hourani, M.; Heal, A.; Duncan, R.C.; Burnett, A.; Ashkar, F.S.; Serafini, A.N.

    1985-05-01

    The usefulness of indium-111 white blood cell scintigraphy in the diagnosis of subacute or chronic bone infection was examined in 21 orthopedic patients. In-111 WBC imaging was compared with gallium-67 and technetium-99m methylene diphosphonate skeletal scintigraphy and bone radiography, all studies being performed within 1 week. In-111 WBC scintigraphy showed no definite advantage over Ga-67 scintigraphy in the identification of chronic bone infection. The two tests had the same sensitivity and similar specificity. Bone radiography had a sensitivity of 60% and a specificity of 67%. A negative Tc-99m MDP bone scintigram ruled out infection, but because of low specific, final evaluation required performance of Ga-67 or In-111 WBC scintigraphy.

  4. Malignant external otitis: The diagnostic value of bone scintigraphy

    SciTech Connect

    Ostfeld, E.; Aviel, A.; Pelet, D.

    1981-06-01

    Technetium99m Methylene Diphosphate bone scintigraphy (BS) of the skull was performed in three patients with malignant external otitis (MEO). Pathological uptake of the radioisotope in the mastoid region was found during the early stages of MEO updating radiologic findings. The extent of the radioisotope accumulation during the early stages of MEO indicates that the actual tissue damage exceeds the clinical estimation. The follow-up BS findings correlate well with the clinical course of MEO indicating either healing or extension to the base of skull.

  5. Bone Scintigraphy in the Diagnosis of Rheumatoid Arthritis: Is There Additional Value of Bone Scintigraphy with Blood Pool Phase over Conventional Bone Scintigraphy?

    PubMed

    Kim, Ji Young; Choi, Yun Young; Kim, Chan Woo; Sung, Yoon-Kyoung; Yoo, Dae-Hyun

    2016-04-01

    We aimed to investigate the value of bone scintigraphy with additional blood pool phase (BSBP), compared with conventional bone scintigraphy (CBS), in the assessment of rheumatoid arthritis (RA). A total of 242 patients (43 males, 199 females; 14-78 years) with arthralgia, and underwent BSBP were retrospectively analyzed. On the first physical examination, active arthritis was found in 128 of the 242 patients. Clinical diagnosis was made by a rheumatologist on the basis of the 1987 American College of Rheumatology (ACR) criteria, which are considered to be the gold standard. The diagnostic performances and prognostic value of BSBP and CBS were analyzed in the total patients with arthralgia and in the patients with arthritis. The sensitivity of BSBP (84.2%, 80/95) were significantly higher than that of CBS (74.8%, 72/95) in the patients with arthralgia (P = 0.039). When BSBP was interpreted with the results of elevated/positive anti-CCP antibody, its accuracy over CBS also became significantly higher (86.0%, 208/242 vs. 83.1%, 201/242 respectively, P = 0.021). The diagnostic odds ratio of BSBP positivity was higher than CBS positivity in the patients with arthralgia (26.0, 12.9-52.4 vs. 21.1, 10.8-41.3) and with arthritis (12.0, 4.9-29.4 vs. 10.0, 4.2-23.4). Both BSBP and CBS appear to provide acceptable accuracy and comparable diagnostic performance for diagnosis of RA. However, in the patients with arthralgia, BSBP was found to be more sensitive than CBS and more accurate when interpreted with the result of anti-CCP antibody. This could help physicians diagnose RA in daily clinical practice. PMID:27051232

  6. Bone Scintigraphy in the Diagnosis of Rheumatoid Arthritis: Is There Additional Value of Bone Scintigraphy with Blood Pool Phase over Conventional Bone Scintigraphy?

    PubMed Central

    2016-01-01

    We aimed to investigate the value of bone scintigraphy with additional blood pool phase (BSBP), compared with conventional bone scintigraphy (CBS), in the assessment of rheumatoid arthritis (RA). A total of 242 patients (43 males, 199 females; 14–78 years) with arthralgia, and underwent BSBP were retrospectively analyzed. On the first physical examination, active arthritis was found in 128 of the 242 patients. Clinical diagnosis was made by a rheumatologist on the basis of the 1987 American College of Rheumatology (ACR) criteria, which are considered to be the gold standard. The diagnostic performances and prognostic value of BSBP and CBS were analyzed in the total patients with arthralgia and in the patients with arthritis. The sensitivity of BSBP (84.2%, 80/95) were significantly higher than that of CBS (74.8%, 72/95) in the patients with arthralgia (P = 0.039). When BSBP was interpreted with the results of elevated/positive anti-CCP antibody, its accuracy over CBS also became significantly higher (86.0%, 208/242 vs. 83.1%, 201/242 respectively, P = 0.021). The diagnostic odds ratio of BSBP positivity was higher than CBS positivity in the patients with arthralgia (26.0, 12.9-52.4 vs. 21.1, 10.8-41.3) and with arthritis (12.0, 4.9-29.4 vs. 10.0, 4.2-23.4). Both BSBP and CBS appear to provide acceptable accuracy and comparable diagnostic performance for diagnosis of RA. However, in the patients with arthralgia, BSBP was found to be more sensitive than CBS and more accurate when interpreted with the result of anti-CCP antibody. This could help physicians diagnose RA in daily clinical practice. PMID:27051232

  7. SPECT/CT imaging in bone scintigraphy of a case of clavicular osteoma

    PubMed Central

    Yamamoto, Yuka; Nishiyama, Yoshihiro

    2014-01-01

    Osteoma is a benign bone-forming tumor that usually arises in the craniofacial bones and rarely in the long bones. Clavicular involvement is extremely rare. We report a 51-year-old woman with osteoma of the left clavicle. Radiograph of the left shoulder showed a well-defined lobulated blastic mass in the proximal and mid-portion of the left clavicle. Bone scintigraphy was performed 4 hours after an intravenous injection of Tc-99m hydroxymethylene diphosphonate (HMDP). Whole-body image showed a focus of intensely increased uptake in the clavicle. Single photon emission computed tomography / computed tomography (SPECT/CT) images were also acquired and clearly showed intense uptake at the tumor site. Integrated SPECT/CT imaging supplies both functional and anatomic information about bone the SPECT imaging improves sensitivity compared with planar imaging, the CT imaging provides precise localization of the abnormal uptake, and information on the shape and structure of the abnormalities improves the specificity of the diagnosis.

  8. Diagnostic sensitivity of bone scintigraphy for equine stifle disorders.

    PubMed

    Graham, Sarah; Solano, Mauricio; Sutherland-Smith, James; Sato, Amy F; Maranda, Louise

    2015-01-01

    Disorders of the stifle are a common cause of lameness in horses yet the accuracy of scintigraphy for diagnosis of stifle conditions is controversial. The aim of retrospective cross-sectional study was to determine the diagnostic sensitivity (Se) of bone scintigraphy in detecting stifle disease and to determine if two orthogonal scintigraphic images improve diagnostic Se. Horses that underwent scintigraphic examination during a two-year period were included. Horses were divided into two groups: group 1 (N = 23) had lameness that was localized to the stifle by intra-articular analgesia and group 2 (N = 182) had lameness that was localized to a different location. Scintigraphic studies (one image or two images) were independently and retrospectively analyzed by two radiologists (R1 and R2). Sensitivity, specificity (Sp) and predictive values (PV), and were calculated for each type of study (one image or two images) and for each radiologist (R1 or R2). The Se to detect stifle disorders varied between radiologists (29.2% and 20.8%). The Sp was 84.5% and 88.3%. When two images were evaluated a decrease in the positive PV for both readers occurred. The Cohen kappa coefficient (κ) between readers was poor when one image (0.084) or two images (0.117) were evaluated. Findings from this study indicated that bone-phase nuclear scintigraphy is reasonably specific but highly insensitive for detecting lameness originating from the stifle in a diverse population of both normal and affected horses. The addition of a caudal scintigraphic image acquisition did not improve diagnostic sensitivity. PMID:25065687

  9. [Research on time-course differential imaging by bone scintigraphy].

    PubMed

    Kawamura, Seiji; Fukushima, Shigehiro; Yoshinaga, Yukiyasu; Kawata, Hidemichi; Miura, Hisao; Miyagawa, Teruo; Fukudome, Yoshifumi; Umezaki, Noriyoshi; Ishibashi, Masatoshi; Morita, Seiichiro; Hayabuchi, Naofumi

    2005-07-20

    The temporal image subtraction technique was applied to bone scintigraphy, using Photoshop (commercially available image processing software) and Morpher (public domain warping software). For the temporal subtraction images, 81 subtraction images (19 cases) were prepared by a method used to subtract the previous images from the current ones. Registration of the current and previous images was performed by manual operation using Photoshop, and warping was done using the warping function of Morpher. In addition, difference images prepared after correcting the distributions of radioactive isotopes of the current and previous images using the count of the pelvic region were also examined. Compared with manual operation, alignment of images by warping improved registration and reduced the generation of pseudo-images of subtraction images. The rate of identification of abnormal accumulation-enhanced regions and subjective evaluation by doctors was improved for warping more than for manual operation. Furthermore, abnormal hot regions, which are difficult to find in film images, could be found in three subtraction images. In addition, it was confirmed that abnormal hot regions become more visible in many cases by preparing subtraction images after correcting the count between images using the count of the pelvic region. Thus, it is suggested that the temporal image subtraction technique in bone scintigraphy enables more accurate observation of enhancement of or changes in abnormal hot regions, which will support diagnostic reading. It is considered that enhancement of or changes in abnormal hot regions will be more accurately understood through further detailed discussion in the future. PMID:16049413

  10. Early postoperative bone scintigraphy in the evaluation of microvascular bone grafts in head and neck reconstruction

    PubMed Central

    Schuepbach, Jonas; Dassonville, Olivier; Poissonnet, Gilles; Demard, Francois

    2007-01-01

    Background Bone scintigraphy was performed to monitor anastomotic patency and bone viability. Methods In this retrospective study, bone scans were carried out during the first three postoperative days in a series of 60 patients who underwent microvascular bone grafting for reconstruction of the mandible or maxilla. Results In our series, early bone scans detected a compromised vascular supply to the bone with high accuracy (p < 10-6) and a sensitivity that was superior to the sensitivity of clinical monitoring (92% and 75% respectively). Conclusion When performing bone scintigraphy during the first three postoperative days, it not only helps to detect complications with high accuracy, as described in earlier studies, but it is also an additional reliable monitoring tool to decide whether or not microvascular revision surgery should be performed. Bone scans were especially useful in buried free flaps where early postoperative monitoring depended exclusively on scans. According to our experience, we recommend bone scans as soon as possible after surgery and immediately in cases suspicious of vascularized bone graft failure. PMID:17448223

  11. 99mTc-red blood cells SPECT and planar scintigraphy in the diagnosis of hepatic hemangiomas.

    PubMed

    Artiko, M V; Sobić-Saranović, P D; Perisić-Savić, S M; Stojković, V M; Radoman, B I; Knezević, S J; Petrović, S N; Obradović, B V; Milović, V

    2008-01-01

    The aim of the study is the assessment of the value of SPECT (single photon emission computerized tomography) using 99mTc-labeled red blood cells in the detection of liver hemangioma, in comparison to planar imaging. With planar red blood cell scintigraphy, sensitivity of the method was 76%, specificity 98%, positive predictive value 98% and negative predictive value 79%. With SPECT, sensitivity of the method was 95%, specificity 98%, positive predictive value 98% and negative predictive value 94%. The smallest lesion detected by planar red blood cell scintigraphy was 1.2 cm, and with SPECT red blood cell scintigraphy 0.8 cm. The use of 99mTc-labeled red blood cells SPECT improved the sensitivity much more in smaller lesions (0.8 to 2 cm), than in bigger ones (2-5 cm). SPECT with radiolabeled red blood cells significantlyy improves the results of scintigraphic findings, especially in the small lesions. PMID:19245136

  12. Uremic Leontiasis Ossea in a Patient With Chronic Renal Insufficiency Demonstrated on Bone Scintigraphy.

    PubMed

    Han, Yeon-Hee; Jeong, Hwan-Jeong; Lim, Seok Tae; Sohn, Myung-Hee

    2016-08-01

    A 37-year-old woman with chronic renal insufficiency underwent bone scintigraphy to evaluate renal osteodystrophy (ROD). Markedly increased uptakes were shown in the maxilla and the mandible, which suggested extensive maxillary and mandibular hypertrophy. CT image revealed that diffuse bony thickening and ground-glass appearance in the skull, maxilla, and mandible with poor distinction of the corticomedullary junction. Whole-body bone scintigraphy images also demonstrated various skeletal characteristics of ROD. This case emphasizes the utility of bone scintigraphy for the surveillance of the whole body in ROD. PMID:27276201

  13. Bone scintigraphy in the initial staging of patients with renal-cell carcinoma: concise communication

    SciTech Connect

    Rosen, P.R.; Murphy, K.G.

    1984-03-01

    The records of 40 consecutive patients who received bone scintigraphy in conjunction with the initial evaluation and staging of renal-cell carcinoma were reviewed to determine the role of bone imaging in this clinical context. Bone scintigrams were positive in three out of 40 patients at the time of diagnosis. In view of the low yield of bone imaging, it appears that routine scintigraphy is unwarranted in the absence of skeletal symptoms before the diagnosis of renal lesions. The presence of a positive bone image did not alter the indication for nephrectomy.

  14. Usefulness of three-phase bone scintigraphy and SPECT/CT for the diagnosis of bone lesions of systemic sarcoidosis

    PubMed Central

    Higashiyama, Shigeaki; Kawabe, Joji; Yoshida, Atsushi; Kotani, Kohei; Shiomi, Susumu

    2014-01-01

    We report a three-phase bone scintigraphy for the diagnosis of a peripheral bone lesion caused by systemic sarcoidosis. A 32-year-old man with suspected osteomyelitis of the right forefinger underwent three-phase bone scintigraphy with Tc-99m hydroxymethylene diphosphonate (HMDP) and single-photon emission computed tomography/computed tomography (SPECT/CT). The lesion was rich in blood flow according to flow study and blood pool study on bone scintigraphy, and was associated with an osteolytic change on SPECT/CT imaging performed 3 hours after injection of a radioisotope (RI). Whole-body bone scintigraphy indicated multiple high levels of abnormal RI accumulation. The findings of the three-phase bone scintigraphy and SPECT/CT suggested the presence of systemic sarcoidosis; however, a subsequent 18F-fluorodeoxyglucose positron emission tomography/CT (FDG-PET/CT) could not exclude the possibility of multiple metastases from testicular tumors. Therefore, testicular enucleation was performed, and the pathological examination confirmed the presence of sarcoidosis.

  15. Bone marrow scintigraphy and computed tomography in myloproliferative disease

    SciTech Connect

    Goldsmith, S.J.; Gilbert, H.S.; Hermann, G.

    1985-05-01

    Peripheral bone marrow (BM) expansion in myeloproliferative disease (MPD) is demonstrated by scintigraphy (scint) with Technetium 99m sulfur colloid (TSC) or Indium III chloride (In). Computed tomography (CT) of the normal adult medullary cavity yields negative attenuation coefficients (AC) which become positive when BM fat is replaced. BM scint and CT of the medullary cavity are obtained in 23 studies in 21 pts: 6 polycythemia vera (PCV), 6 post PCV myeloid metaplasis (MyM), 4 agnogenic MyM, 3 myelodysplasia with refractory anemia, 1 acute myelocytic leukemia and 1 chronic myelocytic with acute leukemic transformation. AC were measured for BM cavity of lower extremities at each third of the femur and tibia. Values ranged from -89 to +289 Hounsfield units. The results are presented in this paper. There was agreement between SCINT and CT in 83% pts and segments. 80% of MB segments with + AC had scint identified BM. BM biopsy of the iliac crest demonstrated fibrosis or blast proliferation in pts with +AC rather than hypercellularity or osteosclerosis. The highest AC values (>200) were seen in pts with blast proliferation and fibrosis. Decreased BM scint visualization and +CT AC correlated with BM fibrosis and may reflect replacement of BM elements or decreased RES function. BM scint and CT are useful to monitor MPD and select BM sites for biopsy.

  16. Bone scintigraphy in plasma-cell myeloma: a prospective study of 70 patients

    SciTech Connect

    Bataille, R.; Chevalier, J.; Rossi, M.; Sany, J.

    1982-12-01

    Radiography and scintigraphy were correlated in 70 patients with recently diagnosed, untreated multiple myeloma, including 59 with and 11 without primary lytic bone lesions. A site-by-site comparison showed that scintigraphy was more sensitive than radiography in only 18% of cases, whereas radiography was more sensitive in 38% (p<0.001). Patients whose bone scan was as sensitive or more so than the radiograph (''hot'' myeloma) had more active disease than those with the ''cold'' form. Remission was indicated by significant regression or disappearance of scintigraphic abnormalities in 90% of cases. The authors conclude that scintigraphy is not helpful in detecting myelomatous bone lesions, but does have prognastic value for diagnosis and chemotherapy: a positive bone scan indicates initial or residual activity.

  17. Bone scintigraphy in plasma-cell myeloma. A prospective study of 70 patients

    SciTech Connect

    Bataille, R.; Chevalier, J.; Rossi, M.; Sany, J.

    1982-12-01

    Radiography and scintigraphy were correlated in 70 patients with recently diagnosed, untreated multiple myeloma, including 59 with and 11 without primary lytic bone lesions. A site-by-site comparison showed that scintigraphy was more sensitive than radiography in only 18% of cases, whereas radiography was more sensitive in 38% (p less than 0.001). Patients whose bone scan was as sensitive or more so than the radiograph (hot myeloma) had more active disease than those with the cold form. Remission was indicated by significant regression or disappearance of scintigraphic abnormalities in 90% of cases. The authors conclude that scintigraphy is not helpful in detecting myelomatous bone lesions, but does have prognostic value for diagnosis and chemotherapy: a positive bone scan indicates initial or residual activity.

  18. Bone scintigraphy in acute renal failure with severe loin pain and patchy renal vasoconstriction.

    PubMed

    Han, J S; Kim, Y G; Kim, S; Lee, M C; Lee, J S; Kim, S H

    1991-01-01

    To evaluate the patterns of renal images and the diagnostic value as a screening test of the whole-body bone and renal scintigraphy with technetium-99m-methylene diphosphonate (99mTc-MDP) or -pyrophosphate (99mTc-PYP), we performed bone scintigraphy in 6 patients with acute renal failure (ARF) with severe loin pain and patchy renal vasoconstriction on postcontrast renal computed tomography (CT). All 6 patients were young and previously healthy but experienced severe loin pain after track events. Five took analgesics. Postcontrast renal CT showed patchy low-density areas or diffuse enhancement immediately after radiocontrast injection and then patchy wedge-shaped enhancement 24 or 48 h later, which subsequently disappeared 72 h later. On the whole-body bone scintigrams with 99mTc-MDP or 99mTc-PYP before obtaining renal CT, there was no increased uptake of isotope in the soft tissue, and multiple patchy increased accumulations of the isotope in the kidney were observed in 5 patients. In 2 patients, renal scintigraphies with technetium-99m-dimercaptosuccinate showed photon-deficient areas in the same areas of patchy isotope accumulation in the whole-body bone scintigraphies. Whole-body image and renal scintigraphy with bone-seeking agents may be useful as a screening test and in the search for the theoretical evidence of ARF with severe loin pain and patchy renal vasoconstriction. PMID:1835520

  19. [Assessment of solitary hot spots of bone scintigraphy in patients with extraskeletal malignancies].

    PubMed

    Tomoda, Y; Ishino, Y; Nakata, H

    2001-11-01

    Bone scintigraphy is widely used to detect bone metastasis owing to its high sensitivity, but solitary focus of increased uptake often causes diagnostic problem because of its low specificity. The purpose of this study was to assess the significance of solitary hot spot detected in patients with extraskeletal malignancies. We reviewed 1,167 consecutive bone scintigraphies of patients with history of lung, breast or prostatic cancer. There was 185 bone scans showing solitary hot spot (lung; 121, breast; 36, prostate; 28). Of the solitary hot spots, 30 (24.8%) in lung cancer, 8 (22.2%) in breast cancer, and 4 (14.3%) in prostatic cancer were a result of metastatic disease. There was no significant difference in the frequency of bone metastasis according to the site of primary tumor. It was relatively higher in the location of pelvis, scapula and thoracic spine. Clinical symptoms, particularly local bone pain, were helpful to diagnose the solitary hot spot. PMID:11806083

  20. Bone Scintigraphy and Panoramic Radiography in Deciding the Extent of Bone Resection in Benign Jaw Lesions

    PubMed Central

    Jamdade, Anshuman; John, Ani

    2013-01-01

    Objective: To find out the value of correlating radiographic and scintigraphic imaging for defining the extent and nature of benign jaw lesions (BJL). Material and Methods: Twenty patients with histologically proven benign lesions of the jaws were investigated pre-operatively by panoramic radiography (PR) and bone scintigraphy (BS). To test the efficacy of combination of these two imaging modalities, their results were compared with intra-operative and histopathological findings. Result: Most of the benign lesions presented radiographically as well-defined bone destructions with fine sclerotic rims. Such lesions were found to be silent on scintigraphs and the extent of radionuclide uptake was same as radiographically visible extent of bone involvement. However, aggressive lesions showed ill-defined bone destructions without sclerotic rims on radiographs and their scintigraphic uptake correctly exceeded the radiographic extent of the bone involvement. Conclusion: The efficacy of combination of both complementary imagings is rewarding in defining the extent of the BJL, especially when radiographic margins are not so well defined. So, that surgical excisions will be complete and the possibility recurrences is reduced. PMID:24298527

  1. Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis

    SciTech Connect

    Uri, N.; Gips, S.; Front, A.; Meyer, S.W.; Hardoff, R. )

    1991-06-01

    Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 {plus minus} 0.16 in patients with NEO and 1.08 {plus minus} 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 {plus minus} 0.24 in NEO patients and 1.05 {plus minus} 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to +4), according to the intensity of the radiopharmaceutical uptake. This method was found to be inferior in the diagnosis of NEO compared with the quantitative method. We conclude that lesion-to-nonlesion ratios greater than 1.5 and 1.3 on bone and gallium 67 scintigraphy, respectively, are indicative of NEO. Quantitative bone scintigraphy, which is quicker to perform, may be used as a single imaging modality for the diagnosis of NEO.

  2. [Planar scintigraphy versus PET in measuring fatty acid metabolism of the heart].

    PubMed

    Kaiser, K P; Feinendegen, L E

    1987-02-01

    In addition to radionuclide ventriculography and thallium scintigraphy, already well established in nuclear medicine, assessment of myocardial metabolism is also of interest for diagnosis and follow-up observations in heart disease. Under aerobic conditions and in the fasting state, the heart muscle primarily oxidizes fatty acids; during ischemia, in contrast, there is slowing of fatty acid turnover and increased anaerobic glycolysis. With 11C-palmitic acid, in humans, reduced fatty acid uptake has been documented in infarcted myocardial regions. The analysis of 11C-palmitic acid in dogs showed a three-phased elimination curve in normal myocardium. In ischemic myocardium, there was diminished utilization of free fatty acids and the glucose utilization was concomitantly increased. After insulin-glucose infusion, as well, there was increased glucose utilization and a reduction in fatty acid utilization. Studies with 11C-palmitic acid require the equipment for positron emission tomography (PET); because of the short half-life of 20.3 minutes, the nuclide must be generated by a cyclotron in the immediate vicinity. In the search for well-suited isotopes for use in planar scintigraphy employing a gamma camera, the uptake and elimination of a variety of isotopically-marked fatty acids were measured and compared with the characteristics of 14C-palmitic acid. For 17-123I-heptadecanic acid (IHA) the elimination curve was similar to that of 14C-palmitate: disadvantage, however, was the relatively high percentage of water soluble marked catabolites which required dual parameter analysis by means of 99-m-technetium pertechnetate or 123I sodium iodide to quantify the amount of myocardial fatty acid utilization through subtraction of the externally measured water soluble catabolite from the externally measured total activity. In studies with the gamma camera in fasting patients in whom 2 to 3 mCi IHA was injected intravenously after symptom limited bicycle ergometry, in healthy

  3. Role of computed tomography and radionuclide scintigraphy in the localization of osteomyelitis in flat bones

    SciTech Connect

    Hernandez, R.J.; Conway, J.J.; Poznanski, A.K.; Tachdjian, M.O.; Dias, L.S.; Kelikian, A.S.

    1985-03-01

    The combined use of radionuclide scintigraphy and computed tomography is recommended for evaluating children with laboratory and clinical data suggestive of flat bone osteomyelitis despite normal conventional radiographs. In addition, computed tomography may be helpful in the presence of abnormal radiographs in determining the exact location of the focus of osteomyelitis and the most suitable route for appropriate drainage or to obtain culture material.

  4. Bone scintigraphy in diabetic osteoarthropathy. [/sup 99m/Tc-methylene diphosphonate

    SciTech Connect

    Eymontt, M.J.; Alavi, A.; Dalinka, M.K.; Kyle, G.C.

    1981-08-01

    Bone scans of patients with diabetic osteoarthropathy of the ankle and foot were characterized by a combination of diffuse and focal increased uptake, similar to that seen with hyperemia and reactive new bone formation. Scintigraphy showed more extensive abnormalities than radiography, with the scan abnormalities sometimes preceding the radiographic changes. The clinical and scintigraphic appearance of osteoarthropathy may improve following strict diabetic control and non-weight-bearing.

  5. Bone Scintigraphy in a Patient With Giant Malignant Solitary Fibrous Tumor of the Pleura.

    PubMed

    Zhao, Long; Liu, JinJun; Li, Qiang; Wang, Huo-Qiang

    2016-06-01

    Chest radiograph performed in a 61-year-old woman to evaluate cough showed a large mass in the right lung. On chest CT images, the mass was measured approximately 8.5 cm. Malignancy was considered, and bone scintigraphy was performed to assess possible osseous metastases. The bone scan images demonstrated increased tracer uptake by the lung mass. The mass was surgically resected, and the pathologic examination confirmed the rare diagnosis of a malignancy solitary fibrous tumors of the pleura. PMID:26914570

  6. Diagnosis of sclerosing cholangitis with technetium 99m-labeled iminodiacetic acid planar and single photon emission computed tomographic scintigraphy

    SciTech Connect

    Rodman, C.A.; Keeffe, E.B.; Lieberman, D.A.; Krishnamurthy, S.; Krishnamurthy, G.T.; Gilbert, S.; Eklem, M.J.

    1987-03-01

    The purpose of this study was to determine whether /sup 99m/Tc-iminodiacetic acid planar biliary scintigraphy combined with single photon emission computed tomography could detect sclerosing cholangitis and provide additional information regarding the extent and severity of disease. Thirteen patients with sclerosing cholangitis and 13 normal control subjects were studied. Scintigraphic results were also compared with previously reported studies of patients with isolated common bile duct obstruction and with primary biliary cirrhosis. The planar scintigraphy in patients with sclerosing cholangitis showed beading or bandlike constrictions of the biliary tract corresponding to lesions seen on cholangiography, and the image pattern was distinctly different from images obtained from patients with isolated common bile duct obstruction or primary biliary cirrhosis. The single photon emission computed tomography images of the liver in patients with sclerosing cholangitis demonstrated multiple focal areas of /sup 99m/Tc-iminodiacetic acid retention, representing bile stasis in intrahepatic bile ducts. Compared to controls, the mean hepatic clearance half-time of /sup 99m/Tc-iminodiacetic acid was markedly delayed in patients with sclerosing cholangitis (6-10 times normal). Individual patients with sclerosing cholangitis had wider variation in isotope clearance half-time from three regions of the liver than patients with isolated common bile duct obstruction, consistent with regional difference in disease severity and variable impairment of bile flow. In 4 patients with sclerosing cholangitis with incomplete filling of the right and left hepatic ducts at cholangiography, planar and single photon emission computed tomographic scintigraphy provided evidence of significant intrahepatic sclerosing cholangitis.

  7. Evaluation of arthritis in Reiter's disease by bone scintigraphy and radiography.

    PubMed

    Lin, W Y; Wang, S J; Lan, J L

    1995-07-01

    Tc-99m MDP bone scans were used to evaluate the articular inflammation in 38 patients with Reiter's disease and compared with clinical examination and radiologic findings. Our data showed that Reiter's disease predominantly involves the lower limbs, especially the heels, which may be a characteristic feature of Reiter's disease. Bone scans revealed a high diagnostic sensitivity in the detection of clinical arthritis in all peripheral joints, especially in the small joints of the four limbs. The diagnostic sensitivity of radiography was generally lower than bone scintigraphy. In the presence of positive radionuclide findings, clinical arthritis was found in most joints. The scintigram, however, detects a greater number of abnormalities than does clinical assessment in the sternoclavicular joints, shoulders, metacarpophalangeal joints, and tarsals. Because of its high sensitivity, bone scintigraphy is capable of detecting subclinical arthritis, and might provide more objective evidence of early inflammatory joint disease and additional information regarding the pattern of joint involvement. In view of the advantages of low patient radiation exposure, high sensitivity, and the ability to survey the whole body, we consider bone scintigraphy as useful and better than radiography in the detection of early articular inflammation and in establishing the extent and pattern of arthritis in Reiter's disease. PMID:7586982

  8. Fracture of the laryngeal cartilage. An incidental finding on bone scintigraphy.

    PubMed

    Steuart, R D; Morrison, R T

    1992-10-01

    A patient complaining of headaches and bone pain at multiple sites had Tc-99m MDP scintigraphy performed for possible bone trauma after a motor vehicle accident. Bone imaging revealed a small focal increase in tracer uptake in the area of the laryngeal cartilage. There was some reluctance to place a label on this abnormality because the findings were so unusual. The initial diagnosis was a probable fracture of the laryngeal cartilage. Computed tomography of the neck also demonstrated a fracture but correctly localized it to the thyroid cartilage. PMID:1424360

  9. Changing indications for bone scintigraphy in patients with osteosarcoma

    SciTech Connect

    Goldstein, H.; McNeil, B.J.; Zufall, E.; Jaffe, N.; Treves, S.

    1980-04-01

    Fifty-six patients with osteosarcoma were studied to determine the onset of pulmonary and bone metastases. While pulmonary metastases were always detected prior to bone metastases in the era before adjuvant chemotherapy, in this study of patients on adjuvant therapy 16% of patients with metastases showed osseous metastases prior to or without pulmonary metastases.

  10. Technetium bone scintigraphy in the diagnosis of osteomyelitis in children

    SciTech Connect

    Hamdan, J.; Asha, M.; Mallouh, A.; Usta, H.; Talab, Y.; Ahmad, M.

    1987-06-01

    In a 5 1/2-year retrospective study of hospitalized children with osteomyelitis who had technetium bone scans, we found that 32 of 38 (84%) had increased radionuclide uptake, 4 (11%) had normal uptake and 2 (5%) had decreased uptake. The two patients with decreased uptake had a stormy course with extensive bone destruction and pathologic fractures in spite of prolonged courses of antibiotic therapy. Decreased uptake on bone scan in patients with clinical evidence of osteomyelitis could indicate a poor prognosis and early surgical drainage is indicated in order to decrease morbidity.

  11. Bone Scintigraphy and CT Findings in Transverse Process Apophysitis.

    PubMed

    Dua, Sumeet G; Ali, Amjad

    2016-07-01

    A 14-year-old avid gymnast presented with recent onset of increasing lower thoracic back pain. Clinical examination revealed point tenderness at about T10 level. Focal uptake was seen to the left of the midline on a bone scan ordered to exclude stress fracture. Spine CT when read in conjunction with the bone scan revealed apophysitis of the transverse process. Apophysitis of the posterior elements of the vertebrae is a rare cause of back pain in adolescents. PMID:26914575

  12. Bone scintigraphy in evaluating the viability of composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and free non-revascularized periosteal grafts

    SciTech Connect

    Berggren, A.; Weiland, A.J.; Ostrup, L.T.

    1982-07-01

    Researchers studied the value of bone scintigraphy in the assessment of anastomotic patency and bone-cell viability in free bone grafts revascularized by microvascular anastomoses in twenty-seven dogs. The dogs were divided into three different groups, and scintigraphy was carried out using technetium-labeled methylene diphosphonate in composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and periosteal grafts placed in different recipient beds. The viability of the grafts were evaluated by histological examination and fluorescence microscopy after triple labeling with oxytetracycline on the first postoperative day, alizarin complexone on the fourth postoperative day, and DCAF on the eleventh postoperative day. A positive scintiscan within the first week following surgery indicated patent microvascular anastomoses, and histological study and fluorescence microscopy confirmed that bone throughout the graft was viable. A positive scintiscan one week after surgery or later does not necessarily indicate microvascular patency or bone-cell survival, because new bone formed by creeping substitution on the surface of a dead bone graft can result in this finding.

  13. Primary Osteosarcoma of the Rib Identified on Bone Scintigraphy.

    PubMed

    Xie, Peng; Huang, Jianmin

    2016-05-01

    Osteosarcomas generally arise in appendicular skeletons, but rarely in the ribs. We described Tc-MDP bone scan findings from a 23-year-old man with right back pain. The images demonstrated elevated activity in the region overlapping the posterior 8th to 10th ribs and in the L9-10 vertebral bodies. CT showed an 8.8 × 8.3 cm mildly peripherally calcified mass arising from the right 10th rib involving the 9th and 10th thoracic vertebrae. Pathological examination confirmed primary osteosarcoma of the rib. PMID:26704734

  14. Insufficiency of Bone Scintigraphy in Vertebral Lesions of Langerhans Cell Histiocytosis Compared to F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and Diagnostic Computed Tomography

    PubMed Central

    Koç, Zehra Pınar; Şimşek, Selçuk; Akarsu, Saadet; Balcı, Tansel Ansal; Onur, Mehmet Ruhi; Kepenek, Ferat

    2015-01-01

    Langerhans cell histiocytosis (LCH) is a benign disorder related to the histiocytes which can infiltrate bone tissue. The most effective method for demonstrating severity of this disease is PET/CT and bone scintigraphy might show bone lesions. We present a seventeen year old male patient with disseminated LCH presented with exophtalmos and having multiple vertebral lesions which were identified by F-18 FDG PET/CT scan and diagnostic CT but not in the bone scintigraphy. PMID:25800594

  15. Utility of bone scintigraphy in diagnosis of post- traumatic osteitis pubis

    PubMed Central

    Kalawat, Tek Chand; Narayan, Ravishwar; Ravi, Parthasarathi; Lakshmi, Amancharla Yadagiri

    2013-01-01

    Minor musculoskeletal injuries usually heal within few weeks with conservative treatment, but in pelvic injuries, symptoms may persist for long duration and patient need medical attention to get relief from disturbing pain symptoms. We present a case of post-trauma osteitis pubis in a 58-year-old female, who reported with lower abdominal and left side hip joint pain since 2 months, after an episode of trivial trauma to her pelvis. Technetium-99m methylene diphosphonate bone scintigraphy was performed, which confirmed the site of injury in symphysis pubis and left hip joint, by increased radiotracer localization at both of these symptomatic sites. PMID:24163517

  16. Utility of bone scintigraphy in diagnosis of post- traumatic osteitis pubis.

    PubMed

    Kalawat, Tek Chand; Narayan, Ravishwar; Ravi, Parthasarathi; Lakshmi, Amancharla Yadagiri

    2013-04-01

    Minor musculoskeletal injuries usually heal within few weeks with conservative treatment, but in pelvic injuries, symptoms may persist for long duration and patient need medical attention to get relief from disturbing pain symptoms. We present a case of post-trauma osteitis pubis in a 58-year-old female, who reported with lower abdominal and left side hip joint pain since 2 months, after an episode of trivial trauma to her pelvis. Technetium-99m methylene diphosphonate bone scintigraphy was performed, which confirmed the site of injury in symphysis pubis and left hip joint, by increased radiotracer localization at both of these symptomatic sites. PMID:24163517

  17. An uncommon case showing three different pathologies on 99mtechnetium-methylene diphosphonate bone scintigraphy

    PubMed Central

    Chakraborty, Partha Sarathi; Karunanithi, Sellam; Dhull, Varun Singh; Kumar, Kunal; Gupta, Ravikant; Tripathi, Madhavi

    2015-01-01

    99mTechnetium-methylene diphosphonate bone scintigraphy (BS) has an important role in evaluating skeletal pathology, especially its extent. Incidental extra-osseous uptake may sometimes be seen in soft-tissue pathologies. We present a 64-year-old female with skull base osteomyelitis referred for BS which revealed involvement of the skull base on the left side, uptake was also noted in bilateral lungs secondary to hypercalcemia of renal failure and in the D12-L1 vertebrae as the patient had a history of Pott's spine. This is perhaps a unique case showing three findings each of a different etiology in the same scan. PMID:25589816

  18. Bone Scintigraphy SPECT/CT Evaluation of Mandibular Condylar Hyperplasia.

    PubMed

    Yang, Zhiyun; Reed, Tameron; Longino, Becky H

    2016-03-01

    Mandibular condylar hyperplasia (CH) is a complex developmental deformity resulting in asymmetries of the hyperplastic condyle. Bone scan SPECT is a sensitive and accurate method of detecting the growth activity of this disorder. This method can be used to quantitate the radionuclide uptake differences between the left and right condyles. Uptake differences of 10% or more between the left and right condyles, with increased uptake ipsilateral to the CH, are considered to be evidence of active growing CH. Quantitative assessment of CH is important to select an appropriate treatment course. Degenerative arthropathies of the temporomandibular joints may result in altered uptake, but this is mostly associated with the side contralateral to the CH. The CT portion of SPECT/CT is useful to assess the condylar dimensions and underlying bony changes. PMID:26111714

  19. Skeletal Metastasis From Carcinoma of the Gall Bladder: Need for Bone Scintigraphy Justified?

    PubMed Central

    Aswani, Yashant; Hira, Priya

    2016-01-01

    Summary Background Carcinoma of the gall bladder has a guarded prognosis with predominant sites of involvement being liver and regional nodes. Osseous metastasis in carcinoma of the gall bladder is rare and hence bone scintigraphy does not form a part of the routine work-up for such patients. Case Reports We describe two patients with carcinoma of the gall bladder with osteolytic metastasis (stage 4). Conservative treatment was planned but both of them succumbed to the illness. Conclusions We thus highlight the importance of performing a bone scan or PET CT in cases of carcinoma of the gall bladder. Besides, our cases challenge Paget’s seed – soil theory for sites of metastasis. PMID:27231491

  20. Diagnostic dilemma of degenerative joint disease, chronic avascular necrosis or metastasis in planar Tc-99m-methylene diphosphonate planar skeletal scintigraphy excluded by single positron emission computed tomography/computed tomography

    PubMed Central

    Jain, Tarun Kumar; Phulsunga, Rohit Kumar; Basher, Rajender Kumar; Kumar, Narendra; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    We present a 71-year-old male patient subjected to skeletal scintigraphy for metastasis work up of prostate cancer. Whole body planar images revealed a solitary focal tracer uptake in left femoral head mimicking as solitary metastatic focus. Single positron emission computed tomography/computed tomography images localized this increased tracer uptake to the subchondral cysts with minimal sclerosis in left femur head with no decrease in size of femur head and was reported as (degenerative joint disease). PMID:26170582

  1. THE BONE SCINTIGRAPHY AS A COMPLEMENTARY EXAM IN THE DIAGNOSIS OF THE AVASCULAR NECROSIS OF THE SESAMOID

    PubMed Central

    Barral, Carlyle Marques; Félix, Arnóbio Moreira; Magalhães, Leonardo Neuenschwander; Carvalho, Luciana Araújo; Machado, Fernando Santana

    2015-01-01

    Objective: This study aimed to present seven cases of avascular necrosis of the sesamoid and report the role of bone scintigraphy in the diagnosis of these patients. Methods: Seven patients with clinical suspicion of avascular necrosis of the sesamoid underwent three-phase bone scintigraphy with 30 mCi of 99mTc-MDP. Results: Most of the patients were young female adults with complaints of limiting pain in the forefoot, who were making use of inappropriate footwear and/or had a history of injury with or without fracture. There was no predominance of either of the feet or between the femoral or tibial sesamoid. Two patients (28.57%) had a bipartite tibial sesamoid and one (14.29%) had splitting of the tibial and fibular sesamoids. In 100% of the patients, three-phase bone scintigraphy, combined with other propaedeutic methods, proved to be crucial for the diagnosis. The initial procedure in all cases was conservative. In four cases (57.14%), there was no remission of symptoms, and surgical excision of the necrotized sesamoid tissue was performed. In all the patients, the therapy used was effective, with complete remission of symptoms, without complications or deformities of the forefoot. Conclusions: Three-phase bone scintigraphy becomes a cornerstone of the propaedeutics when avascular necrosis of the sesamoid is suspected, through contributing towards early and accurate diagnosis and enabling allowing appropriate specialized treatment. PMID:27042628

  2. Bone scintigraphy as cornerstone in the diagnosis of Erdheim-Chester disease.

    PubMed

    García-Gómez, F J; Cambil-Molina, T; Ríos-Martín, J J; de la Riva-Pérez, P A; Calvo-Morón, C; Castro-Montaño, J

    2016-01-01

    The Erdheim-Chester disease (ECD) is an extremely rare form of non-Langerhans cell histiocytosis. The main difficulty for its diagnosis lies in the wide variety of non-specific symptoms and signs that can occur in the disease process, leading, therefore, to there being no clear-cut algorithm as a guide for an optimal biopsy to confirm the diagnosis. An 81-year-old male with history of diabetes insipidus was admitted due to non-specific respiratory signs. Imaging techniques revealed osteoblastic lesions in the lumbar spine. Whole-body bone-scintigraphy (BS) was performed, in which lesions involving the axial and appendicular skeleton, with different rates of osteoblastic activity, were observed. This highlighted a symmetrical severely intense uptake in the knees, leading to an accurate biopsy specimen that enabled making the definitive diagnosis. BS is a widely available, safe, and inexpensive technique that shows a characteristic pattern of uptake for ECD, thus its use is highly recommended for screening and guiding biopsy if clinical suspicion exists. Furthermore, when the scintigraphy pattern is incidentally observed, biopsy of increased uptake areas (tibia preferably) is mandatory in order to rule out the disease. PMID:26750553

  3. Indium-111-chloride and three-phase bone scintigraphy: A comparison for imaging experimental osteomyelitis

    SciTech Connect

    Hoskinson, J.J.; Daniel, G.B.; Patton, C.S. )

    1991-01-01

    To investigate the utility of indium-111-chloride ({sup 111}In-Cl) imaging in detecting osteomyelitis complicating surgical or fracture sites, the proximal tibia of 11 dogs were experimentally infected with Staphylococcus aureus after creation of a cortical defect. The contralateral limb served as a sham-operated control. Animals were serially imaged by radiography, three-phase technetium-99m-methylene diphosphonate (99mTc-MDP) scintigraphy, and {sup 111}In-Cl scintigraphy. There was a significant difference between infected (1.93) and noninfected (1.32) limb's tibia/femur count density ratios on 24-hr (p = 0.0001) and 72-hr (p = 0.0001) {sup 111}In-Cl images. A smaller difference was found for 99mTc-MDP bone-phase tibia/femur ratios (p = 0.0199). Using receiver operator characteristic analysis of tibia/femur ratios, a sensitivity of 61%, specificity of 88%, and positive (75%) and negative (79%) predictive values were determined for the 24-hr {sup 111}In-Cl images. Indium-111-chloride was superior to 99mTc-MDP in differentiating infected and noninfected operative sites.

  4. An analysis of prognostic factors in preleukemia: interest of bone marrow scintigraphy

    SciTech Connect

    Chomienne, C.; Najean, Y.; Vigneron, N.; Dresch, C.; Rain, J.D.

    1984-04-01

    Simultaneous bone marrow scintigraphy with /sup 99m/Tc colloids and 111Indium transferrin was performed on 34 cases of preleukemic anemias and was shown to be of good prognostic value. Groups of different outcome were defined: for a normal and parallel uptake of the two markers, 90% of the patients died of acute leukemia; for a low Indium and high Technetium uptake, only 1 patient out of 15 died of leukemia (P less than 0.001). Standard clinical and hematological data were of no predictive value. Iron kinetic data and CFU/GM colony growth were correlated to the scintigraphic results. Taken together, these three kinetic parameters have a good sensitivity and specificity for the prognosis of preleukemic states.

  5. T1-201 chloride scintigraphy for bone tumors and soft part sarcomas

    SciTech Connect

    Terui, S.; Oyamada, H.; Nishikawa, K.; Beppu, Y.; Fukuma, H.

    1984-01-01

    The author investigated T1-201 chloride as a tumor scanning agent of both tumors and soft part sarcomas. Six bone tumors (2 with Ewing sarcoma, 3 with osteosarcoma and 1 with giant cell tumor) and 3 soft part sarcoma (1 with liposarcoma and 2 with malignant fibrous histiocytoma (MFH)) were examined. All but one MFH were untreated primary cases. The diagnosis was determined from biopsy specimen. One patient with Ewing sarcoma had bone metastases. All cases were subsequently received chemotherpeutic agents. Surgery or local irradiation were also used in treatment. T1-201 scintigraphy were performed with intravenous administration of 2 mCi of T1-201 chloride before initiation of therapy. In addition, follow-up examinations were done in 4 patients (2 with Ewing sarcoma and 2 with osteosarcoma) to study the effect of chemotherapy on T1-201 uptake by the tumor. Tc-99m bone scans were available for comparison in 6 tumor. Ga-67 citrate scans were also examined for the 3 soft part sarcomas. The untreated tumors even in the metastatic lesions of Ewing sarcoma were distinctly visualized with T1-201 in all cases. The distribution of T1-201 in the tumors was sometimes different from that of Tc-99m and similar to that of Ga-67. Of 3 out of the 4 follow-up patients, the post-therapy scan showed reduction in T1-201 uptake more markedly than Tc-99m uptake during effective chemotherapy. The other one patient had not responded to the treatment so that the scan showed no changes in T1-201 uptake. These findings indicate that the tumor imaging with T1-201 is useful in the diagnosis of these malignant tumors and may be of value in assessing the response of bone tumors to chemotherapy.

  6. (18)F-FDG PET/CT versus bone scintigraphy in the follow-up of gastric cancer.

    PubMed

    Sollini, M; Calabrese, L; Zangheri, B; Erba, P A; Gramaglia, A; Gasparini, M

    2016-01-01

    A 53-year-old patient underwent a positron emission tomography/computed tomography with 2-fluoro-2-deoxy-d-glucose ((18)F-FDG PET/CT) in the suspicious of gastric tumor recurrence (mediastinal and abdominal lymph nodes). PET/CT identified only an area of (18)F-FDGuptake in the twelfth thoracic vertebrae. Unexpectedly, a bone scintigraphy revealed many "hot" spots changing the diagnosis (single metastasis versus plurimetastatic disease) and impacting on patient's management. PMID:26653282

  7. SPECT/CT bone scintigraphy to evaluate low back pain in young athletes: common and uncommon etiologies.

    PubMed

    Matesan, M; Behnia, F; Bermo, M; Vesselle, H

    2016-01-01

    Low back pain of various etiologies is a common clinical presentation in young athletes. In this article, we discuss the utility of SPECT/CT bone scintigraphy for the evaluation of low back pain in young athletes. The spectrum of lower spine lesions caused by sports injuries and identifiable on bone scan is presented along with strategies to avoid unnecessary irradiation of young patients. Also covered are pitfalls in diagnosis due to referred-pain phenomenon and normal skeletal variants specific to this age group. PMID:27387155

  8. Hypertrophic pulmonary osteoarthropathy on bone scintigraphy and 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with lung adenocarcinoma

    PubMed Central

    Cengiz, Arzu; Eren, Mine Şencan; Polatli, Mehmet; Yürekli, Yakup

    2015-01-01

    Hypertrophic pulmonary osteoarthropathy (HPOA) is not an uncommon paraneoplastic syndrome that is frequently associated with lung cancer. A 54-year-old male patient with lung adenocarcinoma underwent bone scintigraphy and fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) scanning for initial staging. Bone scintigraphy revealed increased periosteal activity in lower extremities. FDG PET/CT revealed hypermetabolic right lung mass, mediastinal lymph nodes, and mildly increased periosteal FDG uptake in both femurs and tibias. The findings in lower extremities on bone scan and FDG PET/CT were interpreted as HPOA. PMID:26170569

  9. Hypertrophic pulmonary osteoarthropathy on bone scintigraphy and 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with lung adenocarcinoma.

    PubMed

    Cengiz, Arzu; Eren, Mine Şencan; Polatli, Mehmet; Yürekli, Yakup

    2015-01-01

    Hypertrophic pulmonary osteoarthropathy (HPOA) is not an uncommon paraneoplastic syndrome that is frequently associated with lung cancer. A 54-year-old male patient with lung adenocarcinoma underwent bone scintigraphy and fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) scanning for initial staging. Bone scintigraphy revealed increased periosteal activity in lower extremities. FDG PET/CT revealed hypermetabolic right lung mass, mediastinal lymph nodes, and mildly increased periosteal FDG uptake in both femurs and tibias. The findings in lower extremities on bone scan and FDG PET/CT were interpreted as HPOA. PMID:26170569

  10. Frequent occurrence of new hepatobiliary abnormalities after bone marrow transplantation: results of a prospective study using scintigraphy and sonography.

    PubMed

    Jacobson, A F; Teefey, S A; Lee, S P; Hollister, M S; Higano, C A; Bianco, J A

    1993-07-01

    With hepatobiliary scintigraphy and sonography, we prospectively studied the occurrence of new hepatobiliary abnormalities in 18 patients before, and from 1 to 103 days after, bone marrow transplantation (BMT). Prior to BMT, all patients had normal hepatic uptake and visualization of the gallbladder by 60 min on scintigraphy, and no sludge, stones, or other abnormalities on sonography. After BMT, 16 patients (89%) developed new scintigraphic and/or sonographic hepatobiliary abnormalities. Fifteen patients had impaired liver uptake of mebrofenin, while 11 developed gallbladder uptake of mebrofenin, while 11 developed gallbladder sludge and/or stones, and 10 had gallbladder nonvisualization at 60 min. Nevertheless, no patient developed clinical or laboratory evidence of acute cholecystitis. New hepatobiliary abnormalities are more common during the first months post-BMT than clinically suspected, probably reflecting the combined effects of hepatotoxic chemoradiation therapy, graft-versus-host disease, and prolonged administration of parenteral alimentation. Evidence of acute cholecystitis is generally not found. PMID:8317403

  11. What role for radiobiphosphonates bone scintigraphy in the monitoring of an unusual bone giant cell tumor: a case report and literature review

    PubMed Central

    Oueriagli, Salah Nabih; Ghfir, Imad; Guerrouj, Hassna El; Raïs, Nouzha Ben

    2016-01-01

    We report the case of 24 years old female patient, followed since ten years ago for bone giant cell tumor (GCT) of the right knee, which was complicated by pulmonary metastases. Surgical treatment and pulmonary metastasectomies have not allowed definitive cure of this disease with the appearance of metachronous bone lesions after eight years of evolution. The literature review confirms the originality of this observation: the age of the patient, the initial and metastasis locations and the occurrence of lung metastases with unfavorable prognosis. Through this clinical case, the authors highlight the role of radiobiphosphonates bone scintigraphy in detecting synchronous or metachronous bone lesions, and in monitoring of these locations under medical treatment. PMID:27186440

  12. The role of bone scintigraphy in the evaluation of the suspected abused child

    SciTech Connect

    Sty, J.R.; Starshak, R.J.

    1983-02-01

    A comparison was made of the radiographic and scintigraphic skeletal surveys of 261 children who were suspected victims of abuse. Radiography was positive in 105 children and produced false-negative results in 32; scintigraphy was positive in 120 children and produced false-negative results in two. Although radiography has traditionally been used to assess the skeletal injuries of battered children, the authors conclude that scintigraphy should be the screening procedure of choice for children suspected of having been abused.

  13. Bone scintigraphy for neonatal osteomyelitis: simulation by extravasation of intravenous calcium

    SciTech Connect

    Balsam, D.; Goldfarb, C.R.; Stringer, B.; Farruggia, S.

    1980-04-01

    Intravenously administered calcium gluconate has become increasingly popular in the treatment of neonatal tetany. Occasionally, extravasation results in cellulitis, leading to a clinical diagnosis of superimposed osteomyelitis. Osseous scintigraphy, as the accepted modality in the early detection of osteomyelitis, would tend to be used in this circumstance. This case illustrates a false-positive result, probably due to soft-tissue calcification.

  14. Massive Pelvic Lymphadenopathy Due to Recurrent Non-Hodgkin Lymphoma Incidentally Revealed on a 99mTc-MDP Bone Scintigraphy.

    PubMed

    Huang, Jianmin; Xie, Peng

    2016-06-01

    A 58-year-old man underwent Tc-MDP bone scintigraphy to evaluate the cause of diffuse bone pain. The images did not identify the exact cause of his symptoms. However, a "light bulb"-shaped urinary bladder and diffused increased activity in the scrotal region and left thigh were noted, which suggest a mass effect in the pelvis. A CT scan of the pelvis revealed soft tissue compressing the urinary bladder. A diagnosis of recurrent lymphoma was made. PMID:26828142

  15. Comparison of Diagnostic Performance Between Visual and Quantitative Assessment of Bone Scintigraphy Results in Patients With Painful Temporomandibular Disorder

    PubMed Central

    Choi, Bong-Hoi; Yoon, Seok-Ho; Song, Seung-Il; Yoon, Joon-Kee; Lee, Su Jin; An, Young-Sil

    2016-01-01

    Abstract This retrospective clinical study was performed to evaluate whether a visual or quantitative method is more valuable for assessing painful temporomandibular disorder (TMD) using bone scintigraphy results. In total, 230 patients (172 women and 58 men) with TMD were enrolled. All patients were questioned about their temporomandibular joint (TMJ) pain. Bone scintigraphic data were acquired in all patients, and images were analyzed by visual and quantitative methods using the TMJ-to-skull uptake ratio. The diagnostic performances of both bone scintigraphic assessment methods for painful TMD were compared. In total, 241 of 460 TMJs (52.4%) were finally diagnosed with painful TMD. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the visual analysis for diagnosing painful TMD were 62.8%, 59.6%, 58.6%, 63.8%, and 61.1%, respectively. The quantitative assessment showed the ability to diagnose painful TMD with a sensitivity of 58.8% and specificity of 69.3%. The diagnostic ability of the visual analysis for diagnosing painful TMD was not significantly different from that of the quantitative analysis. Visual bone scintigraphic analysis showed a diagnostic utility similar to that of quantitative assessment for the diagnosis of painful TMD. PMID:26765456

  16. Skeletal Scintigraphy

    PubMed Central

    McDougall, I. Ross

    1979-01-01

    Skeletal scintigraphy, using phosphates or diphosphonates labeled with technetium 99m, is a sensitive method of detecting bone abnormalities. The most important and most frequent role of bone scanning is evaluating the skeletal areas in patients who have a primary cancer, especially a malignant condition that has a tendency to spread to bone areas. The bone scan is superior to bone radiographs in diagnosing these abnormalities; 15 percent to 25 percent of patients with breast, prostate or lung cancer, who have normal roentgenograms, also have abnormal scintigrams due to metastases. The majority of bone metastases appear as hot spots on the scan and are easily recognized. The incidence of abnormal bone scans in patients with early stages (I and II) of breast cancer varies from 6 percent to 26 percent, but almost invariably those patients with scan abnormalities have a poor prognosis and should be considered for additional therapies. Progression or regression of bony lesions can be defined through scanning, and abnormal areas can be identified for biopsy. The incidence of metastases in solitary scan lesions in patients with known primary tumors varies from 20 percent to 64 percent. Bone scintigraphy shows positive uptake in 95 percent of cases with acute osteomyelitis. Stress fractures and trauma suspected in battered babies can be diagnosed by scanning before there is radiological evidence. The procedure is free from acute or long-term side effects and, except in cases of very young patients, sedation is seldom necessary. Although the test is sensitive, it is not specific and therefore it is difficult to overemphasize the importance of clinical, radiographic, biochemical and scanning correlation in each patient. ImagesFigure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7.Figure 8.Figure 9.Figure 10. PMID:390886

  17. Diagnostic imaging of musculoskeletal infection. Roentgenography; Gallium, indium-labeled white blood cell, gammaglobulin, bone scintigraphy; and MRI

    SciTech Connect

    Wegener, W.A.; Alavi, A. )

    1991-07-01

    A great deal of effort has been made to evaluate and define the role of various diagnostic imaging techniques in various clinical settings that complicate the diagnosis of osteomyelitis. Except possibly in neonates, bone scintigraphy remains generally recommended when there has been no previous osseous involvement. In other cases of chronic disease, previous fracture or trauma, prosthesis, and diabetic foot, In-WBC scintigraphy is generally accepted as an appropriate imaging technique. MRI will play an increasingly important role in diagnosing osteomyelitis and may prove to be an important adjunct in these cases. Research continues to improve our current diagnostic armamentarium. In-IgG appears to avoid practical deficiencies encountered with 67Ga and In-WBC; it remains to be seen what role this agent will play in routine clinical practice. All agents to date image inflammation, not infection, and most require delayed imaging sessions, usually at 24 hours. These shortcomings necessitate further research to develop new radiotracers that can provide useful images within several hours and that are specific for infection, perhaps ultimately delineating the particular microorganism involved.84 references.

  18. Incremental value of single photon emission tomography/computed tomography in 3-phase bone scintigraphy of an accessory navicular bone.

    PubMed

    Jain, Sachin; Karunanithi, Sellam; Agarwal, Krishan Kant; Kumar, Ganesh; Roy, Shambo Guha; Tripathi, Madhavi

    2014-07-01

    Accessory navicular bone is one of the supernumerary ossicles in the foot. Radiography is non diagnostic in symptomatic cases. Accessory navicular has been reported as a cause of foot pain and is usually associated with flat foot. Increased radio tracer uptake on bone scan is found to be more sensitive. We report a case highlighting the significance of single photon emission tomography/computed tomography in methylene diphosphonate bone scan in the evaluation of symptomatic accessory navicular bone where three phase bone scan is equivocal. PMID:25210293

  19. Diagnostic value of routine bone scintigraphy renal imaging in renal cell carcinoma

    SciTech Connect

    Chancellor, M.B.; Konnak, J.W.; Grossman, H.B.

    1989-05-01

    Technetium-99m-phosphate compounds used in bone scanning are excreted by the kidney, and excellent renal images can be obtained on routine bone scintigrams. The preoperative bone scans of 49 patients who underwent radical nephrectomy for renal cell carcinoma between 1981 and 1985 were reviewed for renal imaging. Ninety-four percent of the patients had abnormal bone scan renal images (82% had focal decreased uptake, and 12% had focal increased uptake). Six percent of the renal images were symmetrical bilaterally. When bone scans are employed in the postoperative follow-up of patients with renal cancer, they can be used to assess the status of the remaining kidney.

  20. Combined bone scintigraphy and indium-111 leukocyte scans in neuropathic foot disease

    SciTech Connect

    Schauwecker, D.S.; Park, H.M.; Burt, R.W.; Mock, B.H.; Wellman, H.N.

    1988-10-01

    It is difficult to diagnose osteomyelitis in the presence of neurotrophic osteoarthropathy. We performed combined (99mTc)MDP bone scans and indium-111 (111In) leukocyte studies on 35 patients who had radiographic evidence of neuropathic foot disease and clinically suspected osteomyelitis. The (111In)leukocyte study determined if there was an infection and the bone scan provided the anatomic landmarks so that the infection could be localized to the bone or the adjacent soft tissue. Seventeen patients had osteomyelitis and all showed increased (111In)leukocyte activity localized to the bone, giving a sensitivity of 100%. Among the 18 patients without osteomyelitis, eight had no accumulation of (111In)leukocytes, seven had the (111In)leukocyte activity correctly localized to the soft tissue, two had (111In)leukocyte activity mistakenly attributed to the bone, and one had (111In)leukocyte accumulation in a proven neuroma which was mistakenly attributed to bone. These three false-positive results for osteomyelitis reduced the specificity to 83%. Considering only the 27 patients with a positive (111In)leukocyte study, the combined bone scan and (111In)leukocyte study correctly localized the infection to the soft tissues or bone in 89%. Uninfected neurotrophic osteoarthropathy does not accumulate (111In)leukocytes. We found the combined bone scan and (111In) leukocyte study useful for the detection and localization of infection to soft tissue or bone in patients with neuropathic foot disease.

  1. Effectiveness of 18F-FDG-PET/CT vs Bone Scintigraphy in Treatment Response Assessment of Bone Metastases in Breast Cancer

    PubMed Central

    Al-Muqbel, Kusai M.; Yaghan, Rami J.

    2016-01-01

    Abstract The aim of the study was to examine the effectiveness of fluorine-18 fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) versus bone scintigraphy (BS) in treatment response assessment of bone metastases in breast cancer. The medical records of breast cancer patients with metastatic bone disease were reviewed retrospectively in our hospital from the period of January 2003 until April 2014. We included in our study patients evaluated by BS and/or 18F-FDG-PET/CT. Group 1 included patients who underwent pre- and post-treatment BS. Group 2 included patients who underwent pre- and post-treatment 18F-FDG-PET/CT scans. Group 3 included patients who underwent pretreatment BS and post-treatment both modalities. Functional and structural bone changes were monitored on pre- and post-treatment scans. Group 1 included 71 patients, average age of 49.5 y (range 28–73 y). Post-treatment results were as follows: 34% stable disease, 43% progressed disease, 19% improved disease, 3% resolved disease, and 2% relapsed disease. Group 2 included 32 patients, average age 53.2 y (ranges between 37 and 78 y). Post-treatment results were as follows: 3% stable disease, 15% progressed disease, 15% improved disease, 53% resolved disease, and 14% relapsed disease. After treatment, the total symptomatic/imaging concordance rate was 51% in BS and 83% in 18F-FDG-PET/CT. Structurally, most patients with newly diagnosed metastatic bone disease had predominantly osteolytic lesions, which became mixed or osteoblastic after treatment as noted on CT images of responders. Group 3 included 8 patients, average age 48.9 y (ranges 32–64 y). Five patients had stable disease according to BS. 18F-FDG-PET/CT was concordant in 3/5 patients and discordant in 2/5 patients. Three patients had progressed disease on BS with concordant findings on 18F-FDG-PET/CT. 18F-FDG-PET/CT was found a powerful tool in treatment response assessment of bone metastases in breast cancer

  2. Comparison of bone scintigraphy and radiography in multiple myeloma. [/sup 99m/Tc-phosphate complexes

    SciTech Connect

    Woolfenden, J.M.; Pitt, M.J.; Durie, B.G.M.; Moon, T.E.

    1980-03-01

    Radionuclide images and skeletal radiographs of 51 patients with multiple myeloma were compared to assess the sensitivity of scintigraphy in detecting radiographically evident disease. Comparable studies were available for 562 sites. The radionuclide image was relatively insensitive in detecting myeloma; it failed to show radiographically evident disease or underestimated its extent at 27% of the sites. On a limited number of serial images there were 7 sites at which a scintigraphic abnormality preceded the radiographic abnormality. No definite correlation was found between scintigraphic findings and hematologic parameters of myeloma activity. Although the radionuclide image may demonstrate a few sites of myeloma before the radiograph, radiography remains the primary method of evaluating skeletal involvement by myeloma.

  3. Diffuse pulmonary uptake of bone-seeking radiotracer in bone scintigraphy of a rare case of pulmonary alveolar microlithiasis

    PubMed Central

    Fallahi, Babak; Ghafary, Bahar Moasses; Fard-Esfahani, Armaghan; Eftekhari, Mohammad

    2015-01-01

    Pulmonary alveolar microlithiasis (PAM) is a rare diffuse pulmonary disease representing microliths formed by deposition of calcium phosphonate in the alveolar airspaces. PAM is often diagnosed incidentally during chest X-ray imaging. Most of them are asymptomatic. We present a 39-year-old man referring for a bone scan due to a complaint of right leg pain. Bone scan showed diffuse uptake of bone-seeking radiotracer on both lung fields predominantly in basal regions. The bronchoalveolar lavage test confirmed the diagnosis of PAM. PMID:26170578

  4. Comparative value of bone scintigraphy and radiography in monitoring tumor response in systemially treated prostatic carcinoma

    SciTech Connect

    Levenson, R.M.; Sauerbrunn, B.J.; Bates, H.R.; Newman, R.D.; Eddy, J.L.; Ihde, D.C.

    1983-02-01

    Radionuclide bone scans and skeletal radiographs were obtained before and during combination chemotherapy or initial hormonal treatment in 46 patients with disseminated adenocarcinoma of the prostate. The purpose of the study was to determine the usefulness of these two modalities in evaluating tumor response to therapy. Prior to treatment, bone scans were positive in 44 patients (96%). In all but one patient either bone radiographs or bone marrow biopsy revealed evidence of osseous metastases. In 22 patients partial response to therapy was documented by a variety of other staging tests.Eleven of these patients showed concurrent or later improvement on bone scans; one showed improvement on a radiograph. ''Flare phenomena'' were observed relatively frequently since 23% of the scans and 50% of the radiographs showed worsening at the time of response. Bone scans revealed worsening in 79% of 33 patients with disease progression of extraosseous tumor; radiographs were equally sensitive (82% worsening). It is concluded that bone scans in particular are ueful for monitoring tumor status in systemically treated patients with prostate cancer. However, because of the lack of sensitivity for response and paradoxical worsening with tumor regression in some patients, scans are not accurate enough to be employed as the sole test in following these patients.

  5. Comparative value of bone scintigraphy and radiography in monitoring tumor response in systemically treated prostatic carcinoma

    SciTech Connect

    Levenson, R.M.; Sauerbrunn, B.J.; Bates, H.R.; Newman, R.D.; Eddy, J.L.; Ihde, DC

    1983-02-01

    Radionuclide bone scans and skeletal radiographs were obtained before and during combination chemotherapy or initial hormonal treatment in 46 patients with disseminated adenocarcinoma of the prostate. The purpose of the study was to determine the usefulness of these two modalities in evaluating tumor response to therapy. Prior to treatment, bone scans were positive in 44 patients (96%). In all but one patient either bone radiographs or bone marrow biopsy revealed evidence of osseous metastases. In 22 patients partial response to therapy was documented by a variety of other staging tests. Eleven of these patients showed concurrent or later improvement on bone scans; one showed improvement on a radiograph. Flare phenomena were observed relatively frequently since 23% of the scans and 50% of the radiographs showed worsening at the time of response. Bone scans revealed worsening in 79% of 33 patients with disease progression of extraosseous tumor; radiographs were equally sensitive (82% worsening). It is concluded that bone scans in particular are useful for monitoring tumor status in systemically treated patients with prostate cancer. However, because of the lack of sensitivity for response and paradoxical worsening with tumor regression in some patients, scans are not accurate enough to be employed as the sole test in following these patients.

  6. Concurrent bisphosphonate-related bilateral atypical subtrochanteric fractures and osteonecrosis of the jaw on bone scintigraphy.

    PubMed

    Kim, Jo Eun; Yun, Mijin; Lim, Sung-Kil; Rhee, Yumie

    2015-05-01

    An 82-year-old woman presented with bilateral thigh pain. She had pain in her right thigh operated for a low-trauma fracture 2 years earlier and newly developed pain in her left thigh without trauma. A whole-body bone scan revealed increased tracer uptake in her bilateral subtrochanteric femoral shafts and in the right mandible without evidence of metastatic bone disease. She had been taking bisphosphonates for 7 years to treat osteoporosis and was soon diagnosed with atypical subtrochanteric fractures and bisphosphonate-related osteonecrosis of the jaw. The bone scan simultaneously identified 2 serious adverse effects of long-term use of bisphosphonates. PMID:25706787

  7. Successful treatment of pain in melorheostosis with zoledronate, with improvement on bone scintigraphy.

    PubMed

    Slimani, Samy; Nezzar, Adlen; Makhloufi, Hachemi

    2013-01-01

    Melorheostosis is a very rare sclerosing bone disorder that involves frequently one limb. It may be asymptomatic, but pain and limb deformity may occur and can be very debilitating. Different reports have indicated efficacy of bisphosphonates (pamidronate and etidronate) on symptoms. We report an adult patient with a very painful melorheostosis, who  improved after treatment with zoledronate, either on symptoms or on bone scans. PMID:23813581

  8. Detection of degenerative disease of the temporomandibular joint by bone scintigraphy: concise communication

    SciTech Connect

    Goldstein, H.A.; Bloom, C.Y.

    1980-10-01

    Nine patients with facial pain were evaluated with limited bone scans. The scintigrams correlated with microscopy in all patients, although radiographs correlated with microscopy in only five patients. The degenerative disease process in the temporomandibular joint was more extensive in the patients with radiographic and scintigraphic abnormalities than in those with scintigraphic abnormalities alone. The limited bone scan appears useful in detecting early degenerative changes in the temporomandibular joint.

  9. Postoperative bone marrow alterations: Potential pitfalls in the diagnosis of osteomyelitis with In-111-labeled leukocyte scintigraphy

    SciTech Connect

    Seabold, J.E.; Nepola, J.V.; Marsh, J.L.; Hawes, D.R.; Justin, E.P.; Ponto, J.A.; Pettit, W.A.; el-Khoury, G.Y.; Kirchner, P.T. )

    1991-09-01

    Scintigraphy was used after injection of technetium-99m methylene diphosphonate (MDP) and indium-111-labeled white blood cells (WBCs) to assess for the presence of osteomyelitis in 97 patients who had undergone prior surgical procedures. Thirty-four patients with abnormal In-111-labeled WBC patterns underwent restudy with Tc-99m albumin colloid (AC). Scintigraphic findings were considered positive for osteomyelitis whenever localization of In-111-labeled WBCs exceeded Tc-99m AC activity in extent or focal intensity (discordant pattern). Ten of 12 patients with culture-proved osteomyelitis had discordant patterns; two had false-negative (concordant) patterns. The cases of 20 of 22 patients without infection who were considered to have osteomyelitis on the basis of patterns of In-111-labeled WBCs and Tc-99m MDP were reclassified correctly on the basis of concordant patterns of In-111-labeled WBCs and Tc-99m AC. Radiocolloid images improved the overall scintigraphic specificity for osteomyelitis from 59% without bone marrow imaging to 92%; sensitivity decreased from 94% to 88%.

  10. Bony expansion in skeletal metastases from carcinoma of the prostate as seen by bone scintigraphy

    SciTech Connect

    Resnik, C.S.; Garver, P.; Resnick, D.

    1984-10-01

    Carcinoma of the prostate often metastasizes to the skeletal system, the usual radiologic pattern being widespread patchy areas of increased density without change in the contour of the involved bones. Radionuclide correlation generally shows multiple foci of increased tracer activity. Less commonly, there is bony sclerosis with expansion of the diameter of the involved bone. Several cases of expansile skeletal metastases from carcinoma of the prostate have appeared in the literature but we know of no published descriptions of the radionuclide findings. We present three patients with carcinoma of the prostate who had skeletal metastases with evidence of bony expansion on both roentgenographic and radionuclide examination. 15 references, 8 figures.

  11. Tc-99m MDP bone scintigraphy in a case of Touraine-Solente-Gole syndrome.

    PubMed

    Mudalsha, Ravina; Jacob, Mj; Jora, Charu; Pandit, Ag

    2011-01-01

    Pachydermoperiostosis is a form of primary hypertrophic osteoarthropathy, also known as Touraine-Solente-Gole syndrome. It is a rare disease. In this report, we present the case of a 29-year-old man with this rare disorder, having significant findings on Tc-99m methylene diphosphonate bone scan. PMID:21969783

  12. Tc-99m MDP bone scintigraphy in a case of Touraine-Solente-Gole syndrome

    PubMed Central

    Mudalsha, Ravina; Jacob, MJ; Jora, Charu; Pandit, AG

    2011-01-01

    Pachydermoperiostosis is a form of primary hypertrophic osteoarthropathy, also known as Touraine-Solente-Gole syndrome. It is a rare disease. In this report, we present the case of a 29-year-old man with this rare disorder, having significant findings on Tc-99m methylene diphosphonate bone scan. PMID:21969783

  13. Differential diagnosis between secondary hyperparathyroidism and aluminum intoxication in uremic patients: Usefulness of /sup 99m/Tc-pyrophosphate bone scintigraphy

    SciTech Connect

    Kinnaert, P.; Van Hooff, I.; Schoutens, A.; Bergmann, P.; Fuss, M.; Dratwa, M.; Vienne, A.; Pasteels, J.L.; van Geertruyden, J.; Vanherweghem, J.L.

    1989-03-01

    Forty-one patients in chronic end-stage renal failure and 4 patients with a functioning kidney transplant presented with spontaneous hypercalcemia or intolerance to vitamin D3 sterols and/or oral calcium supplements. Bone iliac crest biopsy with aluminum staining and Tc-pyrophosphate bone scintigraphy with determination of Fogelman score were performed in all cases. Two patients had aluminum-induced osteomalacia (AL O). Thirty-eight biopsies showed renal osteodystrophy (secondary hyperparathyroidism or various combinations of osteitis fibrosa and osteomalacia): 19 with positive staining for aluminum (RO + AL) and 19 without aluminum deposits (RO). The series also comprised 2 cases of pure osteomalacia (OM), 2 cases of osteoporosis (OP), and 1 case of osteoporosis with aluminum accumulation (OP + AL). Mean Fogelman score in RO patients (9.1 +/- 0.3) was significantly higher than in all other categories (5.9 +/- 0.5 for RO + AL, and scores ranging from 0 to 8 in the last 7 patients, p less than 0.01). Patients with massive aluminum accumulation in bone (greater than 75% of the total trabecular surface) showed no or very low uptake of the isotope by the skeleton. Fogelman scores of 9 or higher were always associated with histological secondary hyperparathyroidism. /sup 99m/Tc-pyrophosphate bone scintigraphy is helpful to distinguish aluminum intoxication from secondary hyperparathyroidism in uremic patients.

  14. False Negative (99m)Tc-Hydroxymethane Diphosphonate Three-phase Bone Scintigraphy and (99m)Tc-besilesomab Scan in Detecting Tibia Osteomyelitis Concomitant with Necrotizing Fasciitis.

    PubMed

    Tan, Teik Hin; Lee, Boon Nang

    2014-09-01

    We described a case of 51-year-old female patient presented with a right calf necrotising fasciitis (NF) where osteomyelitis (OM) was suspected. (99m)Tc-hydroxymethane diphosphonate three-phase bone scintigraphy and (99m)Tc-besilosomab scan failed to demonstrate classical features of OM. The final diagnosis was only made by isolating Acinetobacter sp. in both intra-operative bone and tissue cultures from below-knee amputation. As conclusions, the detection of lower limb OM by (99m)Tc-besilosomab scan is not easy when there is concurrence overlying NF. The unusual three-phase bone scan finding of pericortical accumulation of tracer as an early sign of OM is highlighted in this case. PMID:25538491

  15. Evaluation of intense renal parenchymal activity (hot kidneys) on bone scintigraphy

    SciTech Connect

    Bernard, M.S.; Hayward, M.; Hayward, C.; Mundy, L. )

    1990-04-01

    The bone scintigrams of 600 patients performed over a 12-month period were reviewed. Thirty-six demonstrated abnormalities of the urinary tract of which six cases of intense renal parenchymal activity (hot kidneys) were found. Two cases were related to treatment with the new antineoplastic agent mitoxantrone. In one patient it was related to treatment with calcitonin. Neither of these associations has been previously reported. Recognized causes of hypercalcemia and recent radiotherapy were present in two patients. No cause could be found in the final patient.

  16. Bone scintigraphy as a diagnostic method in unilateral hyperactivity of the mandibular condyles: a review and meta-analysis of the literature.

    PubMed

    Saridin, Carrol P; Raijmakers, Pieter G H M; Tuinzing, Dirk B; Becking, Alfred G

    2011-01-01

    Bone scan analyses and clinical assessment are used to diagnose unilateral condylar hyperactivity (UCH). This review compares the diagnostic accuracy of planar and SPECT bone scans. Studies diagnosing patients with possible UCH using bone scans, published between 1968 and 2008, were included in this review. Of 15 articles that met the inclusion criteria, 7 presented results in sufficient detail to calculate index test characteristics. Three control studies show that the difference in uptake values of the left and right condylar regions in the normal population does not exceed 10%. The pooled sensitivity of the planar bone scan (n=130) was 0.71 (95% confidence interval: 0.57-0.82), which was significantly lower (p=0.04) than that of the bone SPECT technique (n=88), which was 0.90 (0.79-0.97). The pooled specificity of the SPECT scan was 0.95 (0.82-0.99), which did not significantly differ (p=0.58) from that of the planar scan (0.92 (0.83-0.97)). Future studies should include a diagnostic analysis of the data, including two-by-two contingency tables, so the accuracy of the diagnostic test may be evaluated. Bone scans are best performed using SPECT, conducting a quantitative analysis by calculating the percentile differences between the left and right condylar regions. PMID:20970961

  17. Quantitative simultaneous In-111/Tc-99m planar imaging in a long-bone infection phantom

    NASA Astrophysics Data System (ADS)

    Zhu, Xuping; Park, Mi-Ae; Gerbaudo, Victor H.; Moore, Stephen C.

    2007-12-01

    In-111-white-blood-cell and Tc-99m-sulfur-colloid dual-radionuclide imaging are frequently utilized in the evaluation of patients with suspected osteomyelitis. We have developed a quantitative planar imaging method in which Tc-99m and In-111 scans are acquired simultaneously in accurate spatial registration. Long, thin tubes containing only In-111 or Tc-99m were first imaged in a list mode within a water bath inclined with respect to the water surface; from these, 12 energy spectra corresponding to different Tc/In ratios were synthesized. Triple-energy-window (TEW) parameters for scatter and radionuclide crosstalk correction, including scatter windows and weights, were optimized using 100 noise realizations of each of the spectra (1200 total). A long-bone phantom containing a simulated infection site was then imaged in water with five In/Tc ratios; 100 noise realizations of two conjugate-view images were generated from each acquisition (500 total). Two regions of interest (ROIs) were defined, and the ratio of In/Tc count ratios in these two ROIs was evaluated with and without the TEW scatter correction and geometric mean attenuation compensation. The average bias improved from 17.2% to 5.3%, with comparable precision. TEW corrections with non-optimized but practical energy windows also improved the bias to 6.4%. Compared with subjective visual assessment, quantitation of In-111/Tc-99m ratios may improve diagnostic accuracy and could eventually permit grading of osteomyelitis.

  18. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    SciTech Connect

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Callaghan, J.J. )

    1989-08-01

    Although few reports address the use of three-phase bone scanning (TPBS) and {sup 111}In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses.

  19. Septic arthritis of a lumbar facet joint: Detection with bone SPECT imaging

    SciTech Connect

    Swayne, L.C.; Dorsky, S.; Caruana, V.; Kaplan, I.L. )

    1989-08-01

    We present a rare case of septic arthritis of a lumbar facet joint with an associated epidural abscess resulting from Staphylococcus aureus. The infection was initially detected with planar bone scintigraphy and precisely localized with single photon emission computed tomography bone scintigraphy, despite an initially negative radiologic evaluation that included radiographs of the lumbar spine, lumbar myelography, and a postmyelography x-ray computed tomography scan. In the appropriate clinical setting, a bone scan demonstrating unilateral increased activity within the spine should raise the suspicion of inflammatory involvement of the posterior elements.

  20. Skeletal Scintigraphy (Bone Scan)

    MedlinePlus

    ... young patients, sedation is seldom necessary. Risks Allergic reactions to radiopharmaceuticals may occur but are extremely rare and are usually mild. Nevertheless, you should inform the nuclear medicine personnel of any allergies you may have ...

  1. Diagnostic and prognostic value of 99mTc-tetrofosmin scintigraphy in maxillofacial flaps.

    PubMed

    Aigner, Reingard M; Schultes, Guenter; Sorantin, Erich

    2003-02-01

    In oro-maxillofacial malignancies, new therapeutic approaches are placing changing demands on the diverse diagnostic modalities. In contradistinction to mandibular reconstruction of former years, the transplants (microvascular anastomosed pedicled flaps, "flaps") now consist of one or more arteries feeding a soft tissue component attached to a piece of bone suitably fitted to fill the defect. We addressed the diagnostic value of technetium-99m tetrofosmin scintigraphy in differentiating between viability and non-viability of the soft tissue portion of flaps in the immediate postoperative assessment. A total of 60 patients who had received flaps for reconstruction of the mandible after partial resection were investigated with (99m)Tc-tetrofosmin 3-5 days after surgery. Scintigraphy consisted of (a) radionuclide angiography, (b) static planar imaging in four projections starting at 10 min post injection, and (c) single-photon emission tomography (SPET) performed immediately after the planar imaging. Normal perfusion associated with no defects throughout the soft tissue portion of the transplant was observed in 46/60 patients. This scintigraphic pattern was identical to viability and normal postoperative follow-up. Hypoperfusion and small defects on planar and SPET images indicated viability and uncomplicated postoperative healing in 6/60 patients, but non-viability/inadequate healing of the flap in 4/60 patients. Absence of perfusion combined with a large defect on static planar and SPET images definitively showed the non-viability of the flap (4/60 patients). It is concluded that (99m)Tc-tetrofosmin scintigraphy is a sensitive diagnostic tool for the immediate postoperative assessment of the viability and the adequacy of implantation of the soft tissue portion of flaps. Therefore tetrofosmin scintigraphy is an important modality in order (a) to define the optimal therapeutic regimen in the immediate postoperative period and (b) to provide better prognosis. PMID

  2. Bone scintigraphy using Tc-99m DPD and F18-FDG in a patient with SAPHO syndrome.

    PubMed

    Pichler, Robert; Weiglein, Klaus; Schmekal, Barnhard; Sfetsos, Konstantinos; Maschek, Wilhelmine

    2003-01-01

    Synovitis (inflammatory arthritis), acne (pustulosa), palmoplantar pustulosis, hyperostosis and osteitis (bland osteomyelitis) are symptoms forming the acronym SAPHO. We present the case of a 48-year old man with sterno-costo-clavicular hyperostosis and typical pustulosis palmaris. We performed Tc-99m DPD serial bone scanning to monitor the course of disease and to assess therapeutic efficiency. Control bone scans in 2001 showed minor compromises of the ribs and diminished disease activity on collarbones and the sternum after medication with non-steroidal anti-inflammatory drugs (NSAIDs) and bisphosphonates. F-18 FDG PET presented synovial inflammation in the left sterno-clavicular joint but no relevant tracer uptake on clavicles or breastbones. In case of diagnostic doubts F-18 FDG PET could be recommended in order to discriminate bland osteomyelitis from bacterial osteomyelitis or from bone malignancy when SAPHO-syndrome is assumed. PMID:12635949

  3. Incidental Detection of Subcutaneous Myopericytoma of Trunk on FDG PET/CT and Bone Scintigraphy for Imaging of Colon Cancer.

    PubMed

    Demir, Selin Soyluoglu; Sarikaya, Ali; Aktas, Gul Ege; Oz Puyan, Fulya

    2016-08-01

    Myopericytoma is a rare type of unusual soft tissue tumor with perivascular myoid differentiation. A 53-year-old man with the diagnosis of colon cancer was referred to Tc-MDP bone scan and F-FDG PET/CT for staging. A subcutaneous mass located in right lower back with heterogeneous FDG uptake was detected on PET/CT. There was increased osteoblastic activity on MDP bone scan in the same region. Mass was resected and subsequently confirmed as myopericytoma by histopathology. PMID:27124684

  4. Bayesian meta-analysis of test accuracy in the absence of a perfect reference test applied to bone scintigraphy for the diagnosis of complex regional pain syndrome.

    PubMed

    Held, Ulrike; Brunner, Florian; Steurer, Johann; Wertli, Maria M

    2015-11-01

    There is conflicting evidence about the accuracy of bone scintigraphy (BS) for the diagnosis of complex regional pain syndrome 1 (CRPS 1). In a meta-analysis of diagnostic studies, the evaluation of test accuracy is impeded by the use of different imperfect reference tests. The aim of our study is to summarize sensitivity and specificity of BS for CRPS 1 and to identify factors to explain heterogeneity. We use a hierarchical Bayesian approach to model test accuracy and threshold, and we present different models accounting for the imperfect nature of the reference tests, and assuming conditional dependence between BS and the reference test results. Further, we include disease duration as explanatory variable in the model. The models are compared using summary ROC curves and the deviance information criterion (DIC). Our results show that those models which account for different imperfect reference tests with conditional dependence and inclusion of the covariate are the ones with the smallest DIC. The sensitivity of BS was 0.87 (95% credible interval 0.73-0.97) and the overall specificity was 0.87 (0.73-0.95) in the model with the smallest DIC, in which missing values of the covariate are imputed within the Bayesian framework. The estimated effect of duration of symptoms on the threshold parameter was 0.17 (-0.25 to 0.57). We demonstrate that the Bayesian models presented in this paper are useful to address typical problems occurring in meta-analysis of diagnostic studies, including conditional dependence between index test and reference test, as well as missing values in the study-specific covariates. PMID:26479506

  5. The effect of MRI contrast agents on hepatic and splenic uptake in the rabbit during (99m) Tc-MDP bone scintigraphy.

    PubMed

    Qiu, Lin; Tang, Yuhui; Chen, Yue; Huang, Zhanwen; Zhu, Yan; Zhang, Li; Cai, Liang; Wan, Qiang; Feng, Yue

    2015-01-01

    The objective of this study was to investigate the effects of Omniscan® and Magnevist® on (99m) Tc-MDP uptake in rabbits during (99m) Tc-MDP bone scintigraphy. In Experiment Group 1, 30 healthy adult rabbits were randomized into six subgroups (n = 5); each subgroup experienced a different time interval between injections (30 min, 60 min, 120 min, 240 min, 360 min, 24 h). All six subgroups were injected first with Omniscan®, then with (99m) Tc-MDP. After 7 days, the same six subgroups were injected with normal saline followed by (99m) Tc-MDP at the same time intervals. In Experiment Group 2, 20 healthy adult rabbits were allocated randomly to four subgroups (n = 5); each subgroup experienced a different time interval between injections (30 min, 60 min, 120 min, 240 min). All four subgroups were injected first with Magnevist®, then with (99m) Tc-MDP. After 7 days, the same four subgroups were injected with normal saline followed by (99m) Tc-MDP. In all experiments, whole-body skeletal imaging was performed. Liver, spleen, and background were delineated to determine the target-to-background (T/B) ratio. Diffusely increased intake of the imaging agent was seen in the liver and spleen when the injection-time interval between Omniscan® and (99m) Tc-MDP varied from 30 min to 240 min and when the time interval between Magnevist® and (99m) Tc-MDP was 30 min-60 min. The imaging findings are consistent with the results of L/B and S/B ratios in each experiment group. Both Omniscan® and Magnevist® have an effect on (99m) Tc-MDP uptake during bone scanning; the main effect is diffusely increased hepatic and splenic activity. PMID:26036779

  6. Clinical Value of 99Tcm-MDP SPECT Bone Scintigraphy in the Diagnosis of Unilateral Condylar Hyperplasia

    PubMed Central

    Wen, Bing; Shen, Ying; Wang, Chang-Yin

    2014-01-01

    Purpose. To investigate the clinical value of 99Tcm-MDP SPECT for the diagnosis of unilateral condylar hyperplasia (UCH). Methods. One hundred forty-nine patients who underwent mandibular 99Tcm-MDP SPECT between January 2009 and December 2012 were studied, including 105 cases that were clinically suspected of UCH and 44 comparable cases without UCH as a control group. Results. Increased bone activity was observed in the affected condyles for all UCH patients. In the UCH group, the relative percentage uptake on the affected side was 59% (SD ± 4.3%), significantly higher than the 41% (SD ± 4.1%) uptake on the contralateral side (P<0.001). Similarly, the condyle/skull ratio was significantly higher for the affected side (1.66 ± 0.63) than for the contralateral side (1.34 ± 0.34, P < 0.01. No significant difference was found in the control group between the left and right condyles. Values for the sensitivity (95%), specificity (61%), positive (84.4%) and negative (84.6%) predictive values, and accuracy (84.5%) for 99Tcm-MDP SPECT in the diagnosis of UCH were calculated. However, for the hyperplastic condyle, no correlation was observed between the thickness of each cartilage layer and the relative uptake in the SPECT image. Conclusion. 99Tcm-MDP SPECT is accurate for diagnosing UCH and can provide a reference for treatment options. PMID:24901015

  7. In-111 WBC scintigraphy in adult osteomyelitis

    SciTech Connect

    Ehrlich, L.; Martin, R.H.; Saliken, J.

    1984-01-01

    Unlike pediatric bone infections, adult osteomyelitis is commonly related to trauma, surgery, or direct extension from an overlying soft tissue infection. Because of this, the findings on Tc-99m MDP bone scintigraphy tend to be nonspecific. Therefore the value of In-111 WBC scintigraphy in the diagnosis of adult osteomyelitis was evaluated. 52 scans were obtained on 51 adult patients who were consecutively referred to the authors' department with this provisional diagnosis. The diagnosis was confirmed by at least two of the following: positive culture, surgery, x-rays, laboratory results, and clinical response to antibiotics. Of the 52 scans studied the sensitivity was 84%, specificity was 82%, and the accuracy was 83%. False positive results occurred most frequently in patients with inflammatory arthritis. False negative examinations occurred in patients who had In-111 WBC concentration in overlying soft tissue obscuring the bony abnormality. Neither the chronicity of the infection, nor prior treatment with antibiotics created difficulty in scan interpretation. It was concluded that although somewhat less sensitive than TcMDP bone scanning, In-111 WBC scintigraphy is more specific than previously studied radiopharmaceuticals in the assessment of bone infections in the adult population.

  8. Electrochemical planarization

    DOEpatents

    Bernhardt, A.F.; Contolini, R.J.

    1993-10-26

    In a process for fabricating planarized thin film metal interconnects for integrated circuit structures, a planarized metal layer is etched back to the underlying dielectric layer by electropolishing, ion milling or other procedure. Electropolishing reduces processing time from hours to minutes and allows batch processing of multiple wafers. The etched back planarized thin film interconnect is flush with the dielectric layer. 12 figures.

  9. Electrochemical planarization

    DOEpatents

    Bernhardt, Anthony F.; Contolini, Robert J.

    1993-01-01

    In a process for fabricating planarized thin film metal interconnects for integrated circuit structures, a planarized metal layer is etched back to the underlying dielectric layer by electropolishing, ion milling or other procedure. Electropolishing reduces processing time from hours to minutes and allows batch processing of multiple wafers. The etched back planarized thin film interconnect is flush with the dielectric layer.

  10. Indium-111-labeled leukocyte scintigraphy: diagnosis of subperiosteal abscesses complicating osteomyelitis in a child

    SciTech Connect

    Outwater, E.; Oates, E.; Sarno, R.C.

    1988-11-01

    Preoperative /sup 111/In-labeled leukocyte scintigraphy demonstrated extensive subperiosteal abscesses complicating acute bilateral tibial osteomyelitis in a child. Plain radiographs showed only marked soft-tissue swelling; three-phase bone scintigraphy depicted both hot and cold areas consistent with acute osteomyelitis.

  11. AIRWAY IDENTIFICATION WITHIN PLANAR GAMMA CAMERA IMAGES USING COMPUTER MODELS OF LUNG MORPHOLOGY

    EPA Science Inventory

    The quantification of inhaled aerosols could be improved if a more comprehensive assessment of their spatial distribution patterns among lung airways were obtained. A common technique for quantifying particle deposition in human lungs is with planar gamma scintigraphy. However, t...

  12. Planar micromixer

    DOEpatents

    Fiechtner, Gregory J.; Singh, Anup K.; Wiedenman, Boyd J.

    2008-03-18

    The present embodiment describes a laminar-mixing embodiment that utilizes simple, three-dimensional injection. Also described is the use of the embodiment in combination with wide and shallow sections of channel to affect rapid mixing in microanalytical systems. The shallow channel sections are constructed using all planar micromachining techniques, including those based on isotropic etching. The planar construction enables design using minimum dispersion concepts that, in turn, enable simultaneous mixing and injection into subsequent chromatography channels.

  13. When Should ⁹⁹mTc Bone Scintigraphy Be Performed in cT1N0 Non-Small Cell Lung Cancer Patients?

    PubMed

    Li, Hang; Hu, Hong; Wang, Rui; Zhang, Yawei; Xiang, Jiaqing; Liu, Quan; Shi, Wei; Sun, Yihua; Chen, Haiquan

    2015-12-01

    The aim of this retrospective study was to investigate the risk factors for bone metastases (BM) in clinical T1N0 non-small cell lung cancer (NSCLC) patients.From January 2010 to June 2012, 739 patients with primary diagnosed cT1N0 NSCLC were eligible for this study. Clinical variables, including sex, smoking history, age at diagnosis, tumor size, pathologic subtype, preoperative serum Carcino embryonie antigen (CEA) level, lesion imaging performance, and skeletal system symptom, were collected.BM were found in 7 patients (0.95%), in whom 6 patients had skeletal system symptom and 1 had silent metastasis. The frequency of BM was significantly high in younger patients (P = 0.007) and in patients with higher preoperative serum CEA level (P = 0.05). In multivariate analysis, age less than 50 years old (OR = 2.23, 95% CI: 1.56-4.21, P = 0.02), presence of clinical symptom (OR = 3.15, 95% CI: 1.98-6.42, P = 0.008), and CEA level over 5 μg/mL (OR = 2.14, 95% CI: 1.37-3.53, P = 0.03) were independently associated with BM in cT1N0 NSCLC patients.Presence of skeletal system symptom is not the unique criteria for performing BS. Younger age at diagnosis and higher preoperative serum CEA level are also risk factors for BM in cT1N0 NSCLC patients. Therefore, the selection of early-stage NSCLC patients being performed BS should be more precise in the future. PMID:26705216

  14. Radio-iodobenzylguanidine scintigraphy of neuroblastoma: conflicting results, when compared with standard investigations

    SciTech Connect

    Schmiegelow, K.; Simes, M.A.; Agertoft, L.; Berglund, G.; Storm-Mathisen, I.; Andreassen, M.; Salmi, T.T.; Nygard, R.W.; Wiebe, T.; Kreuger, A.

    1989-01-01

    Seventy-one patients with neuroblastoma (NB) and 25 patients with other neoplastic or nonneoplastic diseases were studied with MIBG scintigraphy. Sensitivity and specificity at diagnosis were 94% and 88%, respectively. Of 52 patients with NB studied during follow-up, 14 had on one or several occasions conflicting results, when the findings at MIBG scintigraphy were compared to standard investigations (SI: CT scan, bone scan, x-ray, and ultrasound). The correlation of MIBG scintigraphy and SI to clinical outcome were in these 14 patients not significantly different. Adding VMA-excretion measurements did not significantly improve the predictive value of MIBG scintigraphy or SI. Patients with tumor-suspected lesions only at MIBG scintigraphy should be followed closely and the nature of the lesions should be explored through biopsy.

  15. Is Brown Adipose Tissue Visualization Reliable on 99mTc-Methoxyisobutylisonitrile Diagnostic SPECT Scintigraphy?

    PubMed Central

    Haghighatafshar, Mahdi; Farhoudi, Farinaz

    2016-01-01

    Abstract The 99mTc-MIBI has been used with great value as a diagnostic technique in patients with primary hyperparathyroidism. False-positive scans may occur due to misinterpretation of the physiologic distribution of the 99mTc-MIBI. Reviewing consecutive SPECT scans, we evaluated this possibility and assessed how frequently brown adipose tissue (BAT) is seen on 99mTc-MIBI scintigraphy. Here, we retrospectively reviewed scans of consecutive patients who were evaluated for parathyroid adenomas from March 2015 to June 2015, using dual-phase (early and delayed) planar imaging and SPECT. We identified 60 patients (48 female and 12 male; mean age, 52.25 ± 15.20 years; range, 22–86 years). We detected the presence of 99mTc-MIBI uptake in BAT in 20 of 60 patients (33.33%) in the neck. Although the patients with 99mTc-MIBI uptake in BAT were younger (mean age, 48.85 ± 15.27 years, range, 26–73 years) than the patients with no 99mTc-MIBI uptake (mean age, 53.95 ± 15.07 years, range, 22–86 years), this difference was not statistically significant (P = 0.224). The percentage of female patients with BAT detection was higher (17/48 patients; 37.5%) than that of the male population (3/12 patients; 25%), this difference was not also statistically significant (P = 0.85). In patient population referred to 99mTc MIBI scintigraphy of the parathyroid glands, uptake of 99mTc-MIBI in BAT should not be misinterpreted with 99mTc-MIBI-avid-tumors. Fused SPECT/CT images (not SPECT-only) are necessary to distinguish BAT from bone, muscle, thyroid, myocardium, parathyroids, and other structures in the neck and chest. PMID:26765463

  16. Is Brown Adipose Tissue Visualization Reliable on 99mTc-Methoxyisobutylisonitrile Diagnostic SPECT Scintigraphy?

    PubMed

    Haghighatafshar, Mahdi; Farhoudi, Farinaz

    2016-01-01

    The 99mTc-MIBI has been used with great value as a diagnostic technique in patients with primary hyperparathyroidism. False-positive scans may occur due to misinterpretation of the physiologic distribution of the 99mTc-MIBI. Reviewing consecutive SPECT scans, we evaluated this possibility and assessed how frequently brown adipose tissue (BAT) is seen on 99mTc-MIBI scintigraphy. Here, we retrospectively reviewed scans of consecutive patients who were evaluated for parathyroid adenomas from March 2015 to June 2015, using dual-phase (early and delayed) planar imaging and SPECT. We identified 60 patients (48 female and 12 male; mean age, 52.25 ± 15.20 years; range, 22-86 years).We detected the presence of 99mTc-MIBI uptake in BAT in 20 of 60 patients (33.33%) in the neck. Although the patients with T99mc-MIBI uptake in BAT were younger (mean age, 48.85 ± 15.27 years, range, 26-73 years) than the patients with no 99mTc-MIBI uptake (mean age, 53.95 ± 15.07 years, range, 22-86 years), this difference was not statistically significant (P = 0.224). The percentage of female patients with BAT detection was higher (17/48 patients; 37.5%) than that of the male population (3/12 patients; 25%), this difference was not also statistically significant (P = 0.85).In patient population referred to 99mTc MIBI scintigraphy of the parathyroid glands, uptake of 99mTc-MIBI in BAT should not be misinterpreted with 99mTc-MIBI-avid-tumors. Fused SPECT/CT images (not SPECT-only) are necessary to distinguish BAT from bone, muscle, thyroid, myocardium, parathyroids, and other structures in the neck and chest. PMID:26765463

  17. Myoglobinuria with acute renal failure and hot kidneys seen on bone imaging

    SciTech Connect

    Sheth, K.J.; Sty, J.R.; Johnson, F.; Tisdale, P.

    1984-09-01

    We report a case of myoglobinuria secondary to prolonged seizures. The child showed ''hot kidneys'' with bone scintigraphy. The disease entity and etiologies of nontraumatic rhabdomyolysis are discussed.

  18. Hepatobiliary scintigraphy in children.

    PubMed

    Nadel, H R

    1996-01-01

    Hepatobiliary scintigraphy using iminodiacetic (IDA) radiopharmaceuticals provides clinically useful information on the function of the biliary tract in a variety of pathological processes in children, including neonatal jaundice, gallbladder dysfunction, trauma, and liver transplantation. Phenobarbital premedication (5 mg/kg per day for a minimum of 5 days in divided doses) is used in infants who are being examined for neonatal jaundice to increase the accuracy of 99mTc-IDA scintigraphy in differentiating extrahepatic biliary atresia from neonatal hepatitis. Biliary atresia can be ruled out in an infant if a patent biliary tree is shown with passage of activity into the bowel. If no radiopharmaceutical is noted in the bowel on imaging up to 24 hours, distinction between severe hepatocellular disease and biliary atresia cannot be made. The literature reports 91% accuracy, 97% sensitivity, and 82% specificity for hepatobiliary imaging in the diagnosis of biliary atresia. The impairment of both intrahepatic and extrahepatic biliary drainage is an important cause of liver disease in cystic fibrosis. Hepatobiliary scintigraphy in cystic fibrosis has shown characteristic patterns of dilatation of mainly the left hepatic duct, narrowing of the distal common bile duct, gallbladder dysfunction, and delayed bowel transit. Cholecystitis in children may be acalculous. Sensitivity and specificity for the scintigraphic diagnosis of acute acalculous cholecystitis is reported to range from 68% to 93% and 38% to 93%, respectively. Cholescintigraphy in a suspected bile leak provides information generally not available with other techniques, except for direct cholangiography. If the amount of intraperitoneal accumulation of the tracer is greater than that entering the gastrointestinal tract, surgery is usually indicated. Hepatobiliary imaging in children who have undergone liver transplantation will assess graft vascularity, parenchymal function, biliary drainage, presence of a leak

  19. [Bilateral filter applied to bone scintigraphy].

    PubMed

    Katayama, Yutaka; Ueda, Kentaro; Hiura, Shinsaku; Yamanaga, Takashi; Miyoshi, Hisanori; Ohmura, Masahiro; Shimonishi, Yoshihiro; Tsushima, Hiroyuki; Higashiyama, Shigeaki; Kawabe, Joji; Shiomi, Susumu

    2013-12-01

    The aim of this study is to improve the image quality using a post process rather than a correction process at acquisition time. We used a smoothing filter that is widely used on a compact digital camera. Especially for nuclear medicine, when we use a short acquisition time, we will get images that have a large increase in statistical noise. For those images, we validated the efficiency of the smoothing filter by assessing two characteristic parameters. In addition, we defined the best smoothing filter parameters to get stable images that reduced the influence of statistical noise. PMID:24366556

  20. Stress fractures and bone pain

    SciTech Connect

    Groshar, D.; Even-Sapir, E.; Lam, M.; Israel, O.; Front, D.

    1984-01-01

    Stress fractures result from an unusual repetitive physical activity causing absorption of bone in excess of repair and bone formation. This leads to the weakening of the bone and subsequently to a fracture. It is a benign condition that if recognized in time does not need any treatment besides rest. However, if diagnosis is not made and physical activity continues it may result in severe injury to the bone and a frank fracture may result. Pain is the typical clinical feature and bone scintigraphy, being more sensitive than radiography, is done to establish early diagnosis. The presence of asymptomatic sites of abnormal bone uptake typical of stress fracture in which pain appeared only about 2 weeks after scintigraphy, drew the authors' attention to the question of how close is the relationship between stress fractures and bone pain. Sixty-four military recruits diagnosed as suffering from stress fracture were investigated in order to correlate sites with abnormal uptake of Tc-99m MDP on bone scintigraphy with sites of local pain. In 37 (58%) subjects multiple sites of abnormal uptake were recognised. Of 123 sites of abnormal uptake, 31 (25%) were asymptomatic. In three patients bone pain appeared at the site of the abnormal uptake two weeks after scintigraphy. Bone scintigraphy appears to be more sensitive than bone pain in the diagnosis of stress fractures. The osteoblastic activity which manifests itself by abnormal uptake appears in some cases earlier than the pain caused by the fracture. Present findings may suggest that under certain circumstances, in a population prone to stress fracture, bone scan should be considered as a screening method.

  1. The use of gallium-67 scintigraphy in the diagnosis of acute interstitial nephritis

    PubMed Central

    Graham, François; Lord, Martin; Froment, Daniel; Cardinal, Héloise; Bollée, Guillaume

    2016-01-01

    Background Gallium-67 scintigraphy has been suggested as a noninvasive method to diagnose acute interstitial nephritis (AIN). However, its diagnostic performance and usefulness remain controversial. Methods We retrospectively reviewed the charts of 76 patients who underwent gallium-67 scintigraphy for a suspicion of AIN. Patients were classified based on kidney biopsy and/or clinical probability of AIN. Gallium-67 scintigraphy results were reinterpreted blindly using both posterior planar and single photon emission computed tomography (SPECT) imaging. Intensity of radioisotope uptake in the kidney was graded from 0 to 5. Results The diagnosis of AIN was confirmed in 23 patients and excluded in 44. Nine patients with an uncertain diagnosis were excluded from subsequent analysis. A gallium-67 kidney uptake cutoff of 1 gave a negative predictive value of 100%, whereas a cutoff of 5 had an excellent specificity and positive predictive value for the diagnosis of AIN. When using a cutoff of 3, which had previously been used in the literature, we obtained a sensitivity of 61% and a specificity of 75% with posterior planar imaging. The results of both SPECT and posterior planar imaging modalities were comparable. Conclusions Gallium-67 scintigraphy may be of interest in patients with a clinical suspicion of AIN, especially in those who are unable to undergo kidney biopsy. However, results need to be interpreted with caution and depend on the intensity of gallium-67 kidney uptake. PMID:26798465

  2. Functional fecal retention visualized by (111)In-DTPA colon transit scintigraphy.

    PubMed

    Infante, Jose Rafael; Rayo, Juan I; Serrano, Justo; Dominguez, Maria L; Garcia, Lucia; Moreno, Manuel

    2015-06-01

    Constipation is an extremely common problem in children, varying from mild and short-lived to severe and chronic. Chronic constipation is a serious childhood condition and requires further investigation, including blood test, colonoscopy, radio-opaque marker study, and/or scintigraphy. We present small bowel and colon transit scintigraphy of a 14-year-old girl with history of chronic constipation, abdominal pain, weight loss, and poor response to medical treatment. After oral administration of In-DTPA in water, planar and SPECT/CT images showed normal small bowel transit time and functional fecal retention in colon transit study. PMID:25706788

  3. Estrogen receptor scintigraphy.

    PubMed

    Scheidhauer, K; Scharl, A; Schicha, H

    1998-03-01

    Radio-labeled estrogen receptor ligands are tracers that can be used for functional receptor diagnosis. Their specificity towards receptors, together with the fact that only 50-70% of mammary carcinomas are receptor positive, renders them unsuitable for detection of primary tumors or metastases, and this means that estrogen receptor scintigraphy can be used neither for tumor screening nor for staging. However, both 18F-labeled and 123I-labeled estradiol derivatives are suitable for in vivo imaging of estrogen receptors. Their high specificity, established in animal experiments and in vitro studies has been reproduced in in vivo applications in humans. Tracers with positron radiation emitters are, however, hardly suitable for broad application owing to the short half-life of 18F, which would mean that users would need to be situated close to a cyclotron and a correspondingly equipped radiochemical laboratory. The number of available PET scanners, on the other hand, has increased over the last few years, especially in Germany, so that this, at least, does not present a limiting factor. All the same, 123I-labeled estradiol derivatives will find more widespread application, since the number of gamma-cameras incorporating modern multi-head systems is several times greater. The results of studies with 123I-E2-scintigraphy published to date are very promising, even given the initial technical problems mentioned above. As a method of examination, it could be optimised by using improved tracers with a higher tumor contrast and less disturbance from overlapping in diagnostically relevant locations, for instance, by selecting tracers with higher activities whose excretion is more renal than hepatobiliary. The use of modern multi-head camera systems can also be expected to improve the photon yield. PMID:9646642

  4. Iodine-131 MIBG scintigraphy of the extremities in metastatic pheochromocytoma and neuroblastoma

    SciTech Connect

    Shulkin, B.L.; Shen, S.W.; Sisson, J.C.; Shapiro, B.

    1987-03-01

    Iodine-131 MIBG scintigraphy may be used to determine the presence or absence of metastases to the appendicular skeleton in malignant pheochromocytoma and neuroblastoma. Normal bones show no uptake of (/sup 131/I)MIBG and the joints are seen as photon-deficient areas surrounded by background muscle activity. Discrete concentrations of radioactivity in bone are often seen in patients with malignant pheochromocytoma and neuroblastoma. Bone marrow involvement in neuroblastoma may be indicated by diffuse uptake of (/sup 131/I)MIBG or focal accumulation at the metaphyses. Uncommonly, bone involvement may not be displayed by the (/sup 131/I)MIBG images. Since conventional bone scanning agents may also fail to detect these tumors, skeletal scintigraphy with both (/sup 131/I)MIBG and (/sup 99m/Tc)MDP is necessary to reliably stage malignant pheochromocytoma and neuroblastoma.

  5. Radionuclide evaluation of nonmalignant bone disorders

    SciTech Connect

    Winzelberg, G.G.

    1983-02-01

    Recent advances in nuclear imaging have improved the noninvasive evaluation of patients with nonmalignant bone disorders. When bone scanning agents are combined with bone marrow scanning agents and gallium-67 scintigraphy, a more accurate diagnosis can be obtained. By selecting the appropriate imaging sequence, it is often possible to distinguish cellulitis from underlying osteomyelitis. In patients with total hip replacements, it may be possible to separate postsurgical changes from prosthetic loosening or infection. Stress fractures in joggers may be detected by radionuclide bone scintigraphy before radiographs become abnormal. These nuclear imaging procedures can be done in most hospitals.

  6. Meta-iodobenzylguanidine scintigraphy in neuroblastoma--a comparison with conventional X-ray and ultrasound

    SciTech Connect

    Mueller-Gaertner, H.W.Er.; Erttmann, R.; Helmke, K. )

    1986-01-01

    To evaluate the accuracy of meta-iodobenzylguanidine (MIBG) imaging in comparison with bone X-ray and ultrasound, 15 patients with histologically verified neuroblastoma were investigated using 123- or 131MIBG scintigraphy. 123MIBG and 131MIBG are used as the abbreviations for 123-iodine-labeled-MIBG and 131-iodine-labeled-MIBG, respectively. Either 7.4 MBq 131MIBG (n = 4) or 111-185 MBq 123MIBG (n = 11) was applied, and scans were performed 24 and 48 h PI. Anatomical orientation was provided in selected cases by single-photon emission CT or scintigraphy of other organs. X-ray procedures or ultrasound depicted 27 neuroblastoma manifestations (primary tumors and metastatic deposits); 24 of these (89%) were identified by MIBG scintigraphy. Of 42 primary neuroblastomas and metastatic deposits, 27 (64%) were detected by corresponding bone X-ray or ultrasound. The 15 neuroblastoma lesions depicted solely by MIBG scans were mainly (80%) situated in the skeletal system. Because of the pronounced physiological MIBG uptake by liver tissue, detection of intrahepatic or perihepatic tumor involvement is difficult. MIBG scintigraphy is a safe and noninvasive means of locating a wide range of neuroblastoma lesions. Its main diagnostic advantage in comparison with bone X-ray lies in the detection of bone marrow infiltration.

  7. Thyroid scintigraphy in veterinary medicine.

    PubMed

    Daniel, Gregory B; Neelis, Dana A

    2014-01-01

    Thyroid scintigraphy is performed in cats and dogs and has been used to a limited degree in other species such as the horse. Thyroid scintigraphy is most commonly used to aid in the diagnosis and treatment management of feline hyperthyroidism but is also used in the evaluation of canine hypothyroidism and canine thyroid carcinoma. This article reviews the normal scintigraphic appearance of the thyroid in the cat, the dog, and the horse and the principles of interpretation of abnormal scan results in the cat and the dog. Radioiodine is the treatment of choice for feline hyperthyroidism, and the principles of its use in the cat are reviewed. PMID:24314043

  8. Use of SPECT/CT to confirm inconclusive gastric emptying scintigraphy results.

    PubMed

    Henrichon, Stephen; Seltzer, Marc; Siegel, Alan

    2015-06-01

    A 70-year-old man with cramping, abdominal pain, and diarrhea for 5 months after revision of a Nissen fundoplication underwent further evaluation with solid gastric emptying scintigraphy. On sequential planar images, we were uncertain if activity was present within the stomach or within loops of small bowel. SPECT/CT performed at 4 hours was used to localize the tracer, confirming its presence within the stomach. PMID:25783518

  9. Dipyridamole thallium-201 myocardial scintigraphy

    SciTech Connect

    Not Available

    1988-09-01

    Thallium-201 (/sup 201/Tl) myocardial scintigraphy is a sensitive technique for detecting coronary artery disease. Standardized exercise testing is the most common method for inducing myocardial stress for /sup 201/Tl imaging. Unfortunately, a significant number of patients are unable to undergo adequate treadmill or bicycle exercise. In these patients, pharmacologic stress with dipyridamole provides a safe, efficacious, and reliable alternative.

  10. Thallium 201 Scintigraphy

    PubMed Central

    McKillop, James H.

    1980-01-01

    The radioactive isotope thallium 201 behaves physiologically as a potassium analog, and when injected intravenously accumulates rapidly within the cells of many organs. Uptake of the isotope reflects both regional perfusion and sodium-potassium pump activity. The radionuclide emits 80 keV x-rays which are suitable for scintillation camera imaging. The main clinical application of 201TI scintigraphy has been in myocardial imaging. Abnormal uptake of the isotope results in a cold spot on the myocardial image. In patients with coronary artery disease, the differentiation of ischemic and infarcted myocardium is made by comparing images obtained after injecting the radionuclide at the peak of a maximal exercise test with those obtained after injection at rest. Abnormalities due to ischemia usually are seen only on the stress image whereas fixed defects in both rest and stress studies usually indicate areas of infarction or scarring. Some investigators believe that redistribution images obtained four to six hours after stress injection (without administering further 201TI) give the same information as a separate rest study. The sensitivity of stress imaging for detecting significant coronary disease is of the order of 80 percent to 95 percent, though computer processing of the images may be necessary to achieve the higher figure. The prediction of the extent of coronary disease from 201TI images is less reliable. An abnormal 201TI image is not entirely specific for coronary artery disease and the likelihood of an abnormal image being due to this diagnosis varies according to the clinical circumstances. The main clinical value of 201TI myocardial imaging is likely to be in the noninvasive screening of patients with atypical chest pain or with ambiguous findings on stress electrocardiographic tests. It has also proved useful in studying patients with variant angina or following a coronary bypass operation. It is doubtful whether the technique is clinically helpful in most

  11. Iodine-131 metaiodobenzylguanidine scintigraphy for the location of neuroblastoma: preliminary experience in ten cases

    SciTech Connect

    Geatti, O.; Shapiro, B.; Sisson, J.C.; Hutchinson, R.J.; Mallette, S.; Eyre, P.; Beierwaltes, W.H.

    1985-07-01

    Ten patients with histologically proven neuroblastoma were studied by (/sup 131/I)MIBG scintigraphy. Tumor uptake of the radiopharmaceutical showed a spectrum varying from no uptake in one case, to slight uptake in two, moderate uptake in two and intense uptake in five cases. Iodine-131 MIBG scintigraphy was more effective in demonstrating the extent of neuroblastoma spread than were conventional bone scan and CT in one patient, equal to these modalities in four cases, almost equal in two cases and significantly inferior in three cases. These preliminary results suggest that (/sup 131/I)MIBG scintigraphy is useful in detecting the presence and delineating the distribution of neuroblastoma and may, in certain cases, have therapeutic potential.

  12. Clinical diagnostic application of 111In-DTPA-octreotide scintigraphy in small cell lung cancer.

    PubMed

    Vaccarili, M; Lococo, A; Fabiani, F; Staffilano, A

    2000-01-01

    Some years ago it was proved that a good percentage of small cell lung cancers, classified among cancers of the APUD system, produces somatostatin receptors that can be detected in vivo by scintigraphy with 111In-DTPA-octreotide. With the method in the whole body it is possible to identify the principal neoformation and the probable metastases. The authors present a study of 21 patients afflicted with small cell lung cancer diagnosed histologically. The study, carried out between January 1995 and December 1997, compared the radiologic iconography of the CT scan with the scintigraphic map obtained by a planar scintigraphy and in SPECT 1, 4 and 24-hr after iv injection of 110 MBq of 111In-DTPA-octreotide. The comparison was made with reference to the principal neoplasm and probable metastases. A scintigraphic study, a CT of restaging and a follow-up, done after 3 and 6 months of chemotherapy, on 15 patients with cancer that produces somatostatin receptors proved that the neoplasm sometimes regresses and sometimes progresses. In the latter case, it is possible to identify cerebral, mediastinal and hepatic metastases with the administration of 200 microg of octreotide 3 times a day for 7 days before the scintigraphy. In fact, the administration lowers background activity. The authors concluded that scintigraphy with 111In-DTPA-octreotide plays an important part in the study of patients afflicted with small cell lung cancer. Scintigraphy identifies the subgroups of patients who can be cured with somatostatin analogues together with chemotherapy. Scintigraphy presents a good sensibility in the re-staging and in the follow-up of patients who are treated, even though it is difficult to identify subdiaphragmatic metastases where liver, spleen and kidney show an increase in 111In-DTPA-octreotide. PMID:10939603

  13. Stress scintigraphy using single-photon emission computed tomography in the evaluation of coronary artery disease

    SciTech Connect

    Nohara, R.; Kambara, H.; Suzuki, Y.; Tamaki, S.; Kadota, K.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-05-01

    Twenty-seven patients with angina pectoris, 24 with postmyocardial infarction angina and 7 with normal coronary arteries were examined by exercise thallium-201 emission computed tomography (SPECT) and planar scintigraphy. Exercise SPECT was compared with the reperfusion imaging obtained approximately 2 to 3 hours after exercise. The sensitivity and specificity of demonstrating involved coronary arteries by identifying the locations of myocardial perfusion defects were 96 and 87% for right coronary artery, 88 and 89% for left anterior descending artery (LAD) and 78 and 100% for left circumflex artery (LC). These figures are higher than those for planar scintigraphy (85 and 87% for right coronary artery, 73 and 89% for LAD and 39 and 100% for LC arteries). In patients with 3-vessel disease, sensitivity of SPECT (100, 88 and 75% for right coronary artery, LAD and LC, respectively) was higher than planar imaging (88, 63 and 31%, respectively), with a significant difference for LC (p less than 0.05). In 1, 2 and 0-vessel disease the sensitivity and specificity of the 2 techniques were comparable. Multivessel disease was more easily identified as multiple coronary involvement than planar imaging with a significant difference in 3-vessel disease (p less than 0.05). In conclusion, stress SPECT provides useful information for the identification of LC lesions in coronary heart disease, including 3-vessel involvement.

  14. [Diagnostic utility of 111In-antimyosin Fab scintigraphy in acute myocardial infarction: comparison with 201Tl and 99mTc-pyrophosphate myocardial scintigraphy].

    PubMed

    Morita, M; Naruse, H; Yamamoto, J; Itano, M; Kawamoto, H; Fukutake, N; Ohyanagi, M; Iwasaki, T; Fukuchi, M

    1991-12-01

    To assess the diagnostic accuracy, extent, and characteristics of 111In-antimyosin Fab scintigraphy (In-AM) in acute myocardial infarction (AMI), we studied In-AM in 17 patients with AMI and compared with In-AM, 99mTc-PYP and 201Tl scintigraphy. Intensity of In-AM uptake was classified into 3 grades. Fourteen of 17 patients (82%) showed positive uptake of In-AM. The locations of infarct area diagnosed by In-AM were in accordance with those by electrocardiography. There was a good correlation between the extent score of In-AM planar and that of SPECT (r = 0.72), In-AM SPECT and Tl SPECT (r = 0.79), In-AM planar and PYP planar (r = 0.92), In-AM SPECT and PYP SPECT (r = 0.76), respectively (p less than 0.01). Thus, In-AM is a useful method for diagnosis of AMI. PMID:1838398

  15. Electrochromatography Methods: Planar Electrochromatography

    NASA Astrophysics Data System (ADS)

    Chomicki, Adam; Dzido, Tadeusz H.; Płocharz, Paweł; Polak, Beata

    Planar electrochromatography is a technique in which mixture components are separated in adsorbent layer of a chromatographic plate placed in electric field. In such separation system a mobile phase movement stems from electroosmosis phenomenon. Partition and electrophoresis mechanisms are involved in separation of mixture components with this technique. Two principal modes of planar electrochromatography are described: planar electrochromatography in an open system (PEC) and planar electrochromatography in a closed system (pressurized planar electrochromatography, PPEC). The development of both modes is presented beginning with the first paper on electrochromatography by Pretorius et al. in 1974 and finishing with the last papers by Dzido et al. in 2010. Constructional development of equipment to planar electrochromatography is provided and influence of operating variables on separation efficiency as well. The advantages and challenges of PPEC technique are especially discussed.

  16. Multi-technique imaging of bone metastases: spotlight on PET-CT.

    PubMed

    Azad, Gurdip K; Cook, Gary J

    2016-07-01

    There is growing evidence that molecular imaging of bone metastases with positron-emission tomography (PET) can improve diagnosis and treatment response assessment over current conventional standard imaging methods, although cost-effectiveness has not been assessed. In most cancer types, 2-[(18)F]-fluoro-2-deoxy-d-glucose ((18)F-FDG)-PET is an accurate method for detecting bone metastases. For example, in breast cancer, combined (18)F-FDG-PET and computed tomography (CT) is more sensitive at detecting bone metastases than (99m)technetium (Tc)-labelled diphosphonate planar bone scintigraphy (BS) and there is increasing evidence to support the use of serial (18)F-FDG-PET for the assessment of osseous response to treatment. Preliminary data suggest improved diagnostic accuracy of (18)F-FDG-PET-CT in a number of other malignancies including lung, thyroid, head and neck, gastro-oesophageal cancers, and osteosarcoma. As a bone-specific tracer, there is accumulating evidence to support the use of sodium (18)F-fluoride ((18)F-NaF) PET-CT in the diagnosis of skeletal metastases in breast and prostate cancer, although relatively little data are available to support its use for assessment of treatment response. In prostate cancer, (11)C-choline and (18)F-choline PET-CT have better specificities than (18)F-NaF-PET-CT, but equivalent sensitivities in the detection of bone metastases. We review the current literature for staging and response assessment of bone metastases in different cancers. PMID:26997430

  17. [Nuclear medicine diagnosis of bone metastases].

    PubMed

    Strobel, K

    2009-11-01

    Conventional bone scintigraphy is still the standard investigation for the detection of bone metastases, especially in breast and prostate cancer. In unclear scintigraphic uptakes in the appendicular skeleton conventional x-rays are problem solving in most of the cases. In unclear uptakes in the axial skeleton additional performance of SPECT/CT can increase the specificity. Fluoride-PET/CT is superior to conventional bone scintigraphy but is not yet available in clinical routine. Patients with high-risk breast cancer and patients with lung cancer should be staged with FDG-PET/CT primarily. An additional bone scan is than superfluous. The great advantage of FDG-PET/CT is the fact that bone metastases and organ metastases can be detected in the same investigation. There is a clear trend of shifting patients from conventional nuclear medicine to PET/CT. PMID:20029782

  18. Postoperative osteomyelitis following implant arthroplasty of the foot: diagnosis with indium-111 white blood cell scintigraphy

    SciTech Connect

    Bakst, R.H.; Kanat, I.O.

    1987-11-01

    Many complications can occur following insertion of silicone elastomer implants into the foot. Postoperative infection may be difficult to distinguish from other conditions such as dislodgment, fracture, ectopic and heterotopic new bone formation, synovitis, and bursitis. White blood cell scintigraphy, in conjunction with the clinical scenario, may prove to be an invaluable tool in the diagnosis of postoperative osteomyelitis, subsequent to implant arthroplasties. 32 references.

  19. Radionuclide scintigraphy of bacterial nephritis

    SciTech Connect

    Conway, J.J.; Weiss, S.C.; Shkolnik, A.; Yogev, R.; Firlit, C.; Traisman, E.S.

    1984-01-01

    Pyelonephritis is a leading cause of renal failure and is expected to cost as much as three billion dollars in 1984. The diagnosis of urinary tract infection is usually not difficult. However, localization of the infection within the renal parenchyma as opposed to the collecting system is much more difficult. Flank pain, fever, bacteiuria and evidence of parenchymal involvement by intravenous urography may be absent or unrecognized particularly in the infant. Ultrasound and Nuclear Medicine are advocated as better methods to define parenchymal involvement. Such definition is important in the consideration of treatment since parenchymal involvement of the kidney carries a much more ominous potential outcome than infection restricted to within the collecting system. 38 children with a clinical diagnosis of urinary tract infection were studied. 26 of the patients demonstrated abnormal renal parenchymal findings with Gallium-67 Citrate or Tc-99m Glucoheptonate scintigraphy. Intravenous urography was notably ineffective with only 5 of the 20 interpreted as abnormal due to parenchymal disease or decreased function. 11 were entirely normal while only 5 demonstrated scars or hydronephrosis. Only 10 of 17 patients demonstrated intranvesicoureteral reflux on x-ray or nuclear cystography. Ultrasound depicted 6 of 20 patients as having parenchymal abnormalities. Seven were normal. Nonspecific findings such as dilitation of the renal pelvis or renal enlargement was noted in 11 of the 20 patients. Radionuclide Scintigraphy is the most efficacious modality to detect since acute bacterial nephritis.

  20. Planar scintigraphic imaging of the gastrointestinal tract in clinical practice.

    PubMed

    Middleton, Michael L; Strober, Mark D

    2012-01-01

    In the last 30 years, nuclear medicine has paralleled other imaging fields with the development of 3-dimensional techniques, including single-photon emission computed tomography and positron emission tomography. However, conventional nuclear medicine planar scintigraphy remains a common procedure at most imaging centers. Gastrointestinal studies constitute a significant portion of these planar procedures. The most common gastrointestinal studies, including hepatobiliary, gastric emptying, and gastrointestinal bleeding evaluations, resemble their original protocol. However, serial improvements have optimized the diagnostic efficacy of these procedures. Conventional Technetium-99m sulfur colloid liver/spleen imaging and hepatic blood pool imaging with labeled red blood cells now mainly serve an adjunctive role in the evaluation of equivocal findings on computed tomography. Salivary gland imaging is a less commonly requested evaluation, but can be used to evaluate functional capacity in some disease entities. PMID:22117811

  1. Evaluation of biliary disease by scintigraphy

    SciTech Connect

    Ram, M.D.; Hagihara, P.F.; Kim, E.E.; Coupal, J.; Griffen, W.O.

    1981-01-01

    The value of biliary scintigraphy was studied in 180 patients with suspected biliary tract disease. Most of the patients were investigated additionally by conventional techniques such as cholecystography, cholangiography and ultrasonography. It is concluded that biliary scintigraphy is a simple and safe technique for visualization of the biliary tract. It is particularly useful in the evaluation of acute cholecystitis, in patients with iodine sensitivity obstructive from nonobstructive jaundice.

  2. Normal gallbladder scintigraphy in acute cholecystitis

    SciTech Connect

    Ohrt, H.J.; Posalaky, I.P.; Shafer, R.B.

    1983-03-01

    Normal gallbladder scintigraphy occurs in 2 to 5% of reported patients with acute cholecystitis. Gallbladder visualization is found in patients with acalculous cholecystitis and in those with recent relief of cystic duct obstruction but persistence of inflammation. A patient is reported who had clinical and pathologic findings of acute cholecystitis but normal gallbladder visualization. This reemphasizes that the diagnosis of acute cholecystitis cannot be excluded by normal gallbladder scintigraphy.

  3. Biliary scintigraphy in acute pancreatitis

    SciTech Connect

    Serafini, A.N.; Al-Sheikh, W.; Barkin, J.S.; Hourani, M.; Sfakiankis, G.; Clarke, L.P.; Ashkar, F.S.

    1982-08-01

    A prospective study was carried out in 60 patients to determine the efficacy of /sup 99m/Tc-PIPIDA scintigraphy in differentiating biliary pancreatitis from nonbiliary pancreatitis. Forty patients were classified as having biliary pancreatitis and 20 patients as having the nonbiliary type. Scintigraphic scans were divided into five main types according to the time to visualization of the gallbladder and the time to excretion of /sup 99m/Tc-PIPIDA into the intestinal tract. Normal scans were obtained on 95% of patients (19/20) with nonbiliary pancreatitis; 22.5% of patients (9/40) with biliary pancreatitis had normal scans. It is concluded that elevated amylase levels together with an abnormal biliary scan, as defined by the criteria presented here, indicate biliary pancreatitis, while a normal scan largely excludes such diagnosis.

  4. Biliary scintigraphy in acute pancreatitis

    SciTech Connect

    Serafini, A.N.; Al-Sheikh, W.; Barkin, J.S.; Hourani, M.; Sfakiankis, G.; Clarke, L.P.; Ashkar, F.S.

    1982-08-01

    A prospective study was carried out in 60 patients to determine the efficacy of /sup 99//sup m/Tc-PIPIDA scintigraphy in differentiating biliary pancreatitis from nonbiliary pancreatitis. Forty patients were classified as having biliary pancreatitis and 20 patients as having the nonbiliary type. Scintigraphic scans were divided into five main types according to the time to visualization of the gallbladder and the time to excretion of /sup 99//sup m/Tc-PIPIDA into the intestinal tract. Normal scans were obtained in 95% of patients (19/20) with nonbiliary pancreatitis; 22.5% of patients (9/40) with biliary pancreatitis had normal scans. It is concluded that elevated amylase levels together with an abnormal biliary scan, as defined by the criteria presented here, indicate biliary pancreatitis, while a normal scan largely excludes such diagnosis.

  5. Learning planar ising models

    SciTech Connect

    Johnson, Jason K; Chertkov, Michael; Netrapalli, Praneeth

    2010-11-12

    Inference and learning of graphical models are both well-studied problems in statistics and machine learning that have found many applications in science and engineering. However, exact inference is intractable in general graphical models, which suggests the problem of seeking the best approximation to a collection of random variables within some tractable family of graphical models. In this paper, we focus our attention on the class of planar Ising models, for which inference is tractable using techniques of statistical physics [Kac and Ward; Kasteleyn]. Based on these techniques and recent methods for planarity testing and planar embedding [Chrobak and Payne], we propose a simple greedy algorithm for learning the best planar Ising model to approximate an arbitrary collection of binary random variables (possibly from sample data). Given the set of all pairwise correlations among variables, we select a planar graph and optimal planar Ising model defined on this graph to best approximate that set of correlations. We present the results of numerical experiments evaluating the performance of our algorithm.

  6. Vicarious liver visualization in solitary functioning kidney with technetium-99m ethylenedicysteine renal scintigraphy

    PubMed Central

    Jain, Tarun Kumar; Phulsunga, Rohit Kumar; Gupta, Nitin; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    We present a case of 3-year-old boy who was incidentally diagnosed to have single left kidney on ultrasonography. Dynamic technetium-99m ethylenedicysteine renal scintigraphy was acquired for assessing the existing kidney function showed the tracer localization in bilateral renal fossae during the entire study. The single-photon emission computerized tomography/computerized tomography study revealed activity in the right renal fossa to be in the enlarged right lobe of the liver, which was mimicking as impaired functioning right kidney in planar images. The hybrid imaging helped in accurate delineation of tracer uptake by confirming it to be the false appearance of the right kidney in planar imaging. This case report also highlights the possible mechanism of renal tracer uptake in the liver parenchyma. PMID:26170576

  7. Myocardial scintigraphy with 201thallium in pediatric cardiology: A review of 52 cases

    SciTech Connect

    Bjoerkhem, G.E.; Evander, E.; White, T.; Lundstroem, N.R. )

    1990-01-01

    We report our experience of myocardial scintigraphy with 201thallium (201Tl) in 52 children, aged 4 days to 18 years, in which 80 studies were made primarily to demonstrate or exclude impaired myocardial perfusion. For analysis, the patients were divided into the following eight groups: group I, coronary artery malformations (five patients); group II, Kawasaki's syndrome (six patients); group III, arterial switch operation (seven patients); group IV, dilated cardiomyopathy (18 patients); group V, hypertrophic cardiomyopathy (four patients); group VI, myocardial dysfunction after surgery for congenital heart disease (five patients); group VII, pulmonary atresia (three patients); and group VIII, miscellaneous (four patients). Myocardial scintigraphy was performed with a planar or tomographic technique at rest or after exercise (four patients). Isotope-uptake defects, indicating impaired myocardial perfusion, were present in 14 patients, including small infants. Defects were seen in all groups except those with hypertrophic cardiomyopathy and pulmonary atresia. The absence of such defects in several of the patients with Kawasaki's syndrome was particularly valuable as it made coronary angiography unnecessary. In the other groups of patients myocardial scintigraphy was a valuable adjunct to other investigations.

  8. Hysterosalpingo-radionuclide scintigraphy (HERS)

    SciTech Connect

    Iturralde, M.; Venter, P.F.

    1981-10-01

    A radionuclide procedure, hysterosalpingo-radionuclide scintigraphy (HERS), was designed to evaluate the migration of a particulate radioactive tracer from the vagina to the peritoneal cavity and ovaries as well as to image and functionally outline the patency of the pathways between these two extremes of the female reproductive system. Technetium-99m human albumin microspheres (99mTc-HAM) were deposited in the posterior fornices of patients who were divided into two specific groups. Group I consisted of patients who were to undergo different elective gynecologic operations, in which besides obtaining sequential images, radioactivity levels were measured in the removed organs and tissues. Group II consisted of patients referred by the Infertility Clinic for evaluation of their reproductive system pathways patency. In this latter group, HERS was compared with contrast hysterosalpingography (HSG) and peritoneoscopy (PCP). The results obtained from measurements of radioactivity levels on the removed surgical specimens and comparison with other conventional gynecologic diagnostic procedures provide accurate evidence of the migration of 99mTc-HAM from the vagina, through the uterus and tubes, to the peritoneal cavity and ovaries, and show that HERS is a simple noninvasive method for functionally imaging and assessing the patency of the female reproductive system pathways.

  9. Which metabolic imaging, besides bone scan with 99mTc-phosphonates, for detecting and evaluating bone metastases in prostatic cancer patients? An open discussion.

    PubMed

    Bombardieri, E; Setti, L; Kirienko, M; Antunovic, L; Guglielmo, P; Ciocia, G

    2015-12-01

    to discuss the opportunities and the drawbacks of these current diagnostic tests in a scenario where planar scintigraphy and/or SPECT with phosphonates, is the only metabolic imaging recommended by the most important Guidelines of the Scientific Societies dealing with prostate cancer. Other nuclear medicine modalities are in very few cases just cited, never recommended except in rare situations. Is there space for agents other than 99mTc-phosphonates to image bone lesions from prostate cancer? PMID:26337240

  10. Simultaneous pancreatic-renal transplant scintigraphy

    SciTech Connect

    Shulkin, B.L.; Dafoe, D.C.; Wahl, R.L.

    1986-12-01

    99mTc-DTPA scintigraphy was evaluated in seven patients as a technique to assess perfusion of the transplanted pancreas and kidney. Such scans provide high-quality images of both organs in both the flow phase and later phases. The radionuclide is readily available and its brief effective half-life allows repeated evaluations at short intervals. /sup 131/I-hippuran, the major radiopharmaceutical for renal transplant scintigraphy, does not allow visualization of the transplanted pancreas or evaluation of its blood supply. Although the blood glucose is a gross indicator of the function of the pancreatic allograft, pancreatic scintigraphy with 99mTc-DTPA in one case was capable of detecting graft dysfunction before elevation of the blood glucose occurred. While additional studies will be necessary to determine the predictive value of this test, 99mTc-DTPA is valuable for pancreatic-renal transplant evaluation.

  11. Bone Scan or 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography; Which Modality Better Shows Bone Metastases of Breast Cancer?

    PubMed Central

    Balci, Tansel A.; Koc, Zehra P.; Komek, Halil

    2012-01-01

    Background In this multicenter study, we aimed to compare concurrent 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and bone scan results of breast cancer patient. Patients and Methods 162 patients with breast cancer (158 female, 4 male; mean age 50.6 years) were included in the study. FDG PET/CT examination was performed in all patients, and concurrent bone scintigraphy in 68 patients. The results of FDG PET/CT and bone scan were compared. Results 132 of the 162 patients were operated on because of breast cancer. 89 patients had metastasis, and 4 had recurrent disease according to FDG PET/CT results. Metastatic sites in order of frequency were lymph nodes, bone, lung, liver, adrenal gland, local skin or muscle, brain, and peritoneum (peritonitis carcinomatosa). The sensitivity, specificity, accuracy, and negative and positive predictive value of bone scintigraphy versus FDG PET/CT were 96 vs. 100%, 100 vs. 98%, 100 vs. 83%, 100 vs. 100%, and 90 vs. 100%, respectively. Conclusion Although the 2 modalities were in concordance with each other, in 5 (21%) cases, FDG PET/CT could not show bone metastasis which were detected on bone scintigraphy. Hence, bone scintigraphy was superior to FDG PET/CT in the determination of bone metastasis derived from breast cancer. However, FDG PET/CT should be considered for soft tissue metastasis. PMID:24647778

  12. The role of single-photon emission computed tomography/computed tomography in benign and malignant bone disease.

    PubMed

    Horger, Marius; Bares, Roland

    2006-10-01

    of bone scintigraphy. This was mainly achieved by identifying benign bone conditions with increased bone turnover. Therefore, SPECT/CT should be applied whenever equivocal findings of planar bone imaging occur. It also helps to improve accuracy of leukocyte scanning to detect/exclude osteomyelitis and to define sites of inflammation. We therefore regard SPECT/CT as a valuable tool to optimize bone imaging, which might become even more important if new radiopharmaceuticals become available to image specific cell functions. PMID:16950146

  13. Guidelines for radioiodinated MIBG scintigraphy in children.

    PubMed

    Olivier, Pierre; Colarinha, Paula; Fettich, Jure; Fischer, Sibylle; Frökier, Jörgen; Giammarile, Francesco; Gordon, Isky; Hahn, Klaus; Kabasakal, Levent; Mann, Mike; Mitjavila, Mercedes; Piepsz, Amy; Porn, Ute; Sixt, Rune; van Velzen, Jeannette

    2003-05-01

    These guidelines on the use of radioiodinated (99m)Tc-MIBG scintigraphy in children, which summarise the views of the Paediatric Committee of the European Association of Nuclear Medicine, provide a framework which may prove helpful to nuclear medicine teams in daily practice. They have been influenced by the conclusions of the "Consensus Guidelines for MIBG Scintigraphy" (Paris, November 6, 1997) of the European Neuroblastoma Group and by those of the Oncological Committee of the French Society of Nuclear Medicine. The guidelines should be taken in the context of "good practice" and any local/national rules which apply to nuclear medicine examinations. PMID:12658506

  14. Incidental Warthin Tumor on Pertechnetate Scintigraphy.

    PubMed

    Kulkarni, Mukta; Shetkar, Shubhangi; Joshi, Prathamesh; Kasaliwal, Sanket; Chaudhari, Shrikant

    2016-09-01

    A 30-year-old woman underwent Tc-pertechnetate scintigraphy for evaluation of thyrotoxicosis. The scintigraphy revealed hypervascular thyroid gland with markedly increased trapping function in both the lobes suggesting diagnosis of Graves disease. Incidentally, a hypervascular and pertechnetate avid focus was seen along the lateral margin of the right parotid gland. Pertechnetate avidity and site of uptake suggested possibility of Warthin tumor. Clinical examination and ultrasonography revealed a well-defined lesion in the superficial lobe of the right parotid gland favoring diagnosis of benign lesion. Postsurgery specimen confirmed diagnosis of Warthin tumor. PMID:27405035

  15. [Bone gammagraphy for evaluating free vascularized bone grafts in mandibular reconstruction].

    PubMed

    Serra, J M; Paloma, V; Mesa, F; Ballesteros, A; Richter, J A

    1989-01-01

    In oncology jaw reconstruction, the probability of infection, sequestration and failure in scarring is high. For this reason, we use a vascularized free bone graft, whose direct blood flow makes it much more resistant to support the attendant properly. The use of bone scintigraphy by means of three phases acquisition technique is very effective to evaluate the viability of these vascularized grafts during the first days after surgery, in order to adjust the attendant treatments and to prevent the possible complications. PMID:2641826

  16. Growth Arrest Line Mimicking Lymphoma Involvement: The Findings of (99m)Tc-MDP Bone SPECT/CT and Serial Bone Scan in a Child with Non-Hodgkin's Lymphoma.

    PubMed

    Kim, Chanwoo; Kim, Ji Young; Choi, Yun Young; Lee, Seunghun; Lee, Young-Ho

    2016-06-01

    Growth arrest lines appear as dense sclerotic lines parallel to the growth plate of long bones on radiography. We describe the case of a 9-year-old female with growth arrest lines initially masquerading as lymphoma involvement on (99m)Tc-MDP bone scintigraphy who had been treated with chemotherapy for non-Hodgkin's lymphoma about 3 years previously. Subsequent regional bone SPECT/CT clearly diagnosed the growth arrest lines, and retrograde review of previous bone scintigraphy demonstrated line migration in this patient. Growth arrest lines should be considered a possible diagnosis on bone scintigraphy, especially in the surveillance of children who have experienced severe childhood infections, malnutrition, immobilization, or treatment with immunosuppressive or chemotherapeutic drugs that may inhibit bone growth. PMID:27275365

  17. Bone scintigraphy in the reflex sympathetic dystrophy syndrome

    SciTech Connect

    Kozin, F.; Soin, J.S.; Ryan, L.M.; Carrera, G.F.; Wortmann, R.L.

    1981-02-01

    Sixty-four consecutive patients were studied for possible reflex sympathetic dystrophy syndrome (RSDS). They were divided into five groups, based upon specific clinical criteria, and the radiographic and scintigraphic findings in each group were examined. Osteoporosis was the most common radiographic abnormality. Scintigraphic abnormalities were noted in 60% of RSDS patients but in only 7% of the others. These findings included increased blood flow and enhanced periarticular radionuclide activity in the affected extremity. The scan may reflect an active, potentially reversible disorder of local blood flow in RSDS. Furthermore, the scintigraphic patterns may be useful in the diagnosis and in predicting which patients are likely to respond to systemic steroid therapy.

  18. Evaluation of primary lung cancer with indium 111 anti-carcinoembryonic antigen (type ZCE-025) monoclonal antibody scintigraphy

    SciTech Connect

    Krishnamurthy, S.; Morris, J.F.; Antonovic, R.; Ahmed, A.; Galey, W.T.; Duncan, C.; Krishnamurthy, G.T. )

    1990-02-01

    A study was undertaken to test whether indium 111 (111In)-labeled anti-carcinoembryonic antigen (CEA) (type ZCE 025) monoclonal intact antibody (MoAb) would concentrate in primary lung cancer enabling its detection and localization by scintigraphy. The scintigraphic results were correlated with chest radiograph, computed tomograph (CT), bronchoscopy, surgical resection, and tumor CEA analysis. Twenty adult male patients with clinical suspicion of primary lung cancer were studied. Each subject was infused with 4 to 5 mCi of 111In anti-CEA ZCE 025 MoAb, and planar and tomographic scintiphotos were obtained on days 3 and 6 or 7 postinfusion. The scintigraphy was true-positive in 12 of 16 patients with primary lung cancer, eight of nine patients with squamous cell carcinoma, and four of seven with adenocarcinoma; it was true-negative in three of four patients with benign lung disease with an overall accuracy of 75%. In seven patients with confirmed primary lung cancer, but with negative bronchoscopic findings, the scintigraphy was true-positive in four. In 11 patients with definitely positive or suspicious malignancy by bronchoscopy the monoclonal scintigraphy was positive in eight. In true-positive cases, the location and size of the lesion by 111In anti-CEA ZCE 025 MoAb imaging correlated well with CT findings and also tumor mass at surgery. Only one of 12 tumors stained positive for CEA had serum CEA levels greater than 10 ng/ml, indicating nonleakage of the tumor antigen into general circulation in early lung cancer. It is concluded that 111In anti-CEA ZCE 025 MoAb planar and tomographic imaging shows potential to serve as a noninvasive diagnostic test in the evaluation of primary lung cancer. The lung lesion is likely to be malignant if it concentrates 111In anti-CEA ZCE 025 MoAb and benign if it does not.

  19. Enjoyment of Euclidean Planar Triangles

    ERIC Educational Resources Information Center

    Srinivasan, V. K.

    2013-01-01

    This article adopts the following classification for a Euclidean planar [triangle]ABC, purely based on angles alone. A Euclidean planar triangle is said to be acute angled if all the three angles of the Euclidean planar [triangle]ABC are acute angles. It is said to be right angled at a specific vertex, say B, if the angle ?ABC is a right angle…

  20. Comparison of N-isopropyl (/sup 123/I) p-iodoamphetamine brain scans using Anger camera scintigraphy and single-photon emission tomography

    SciTech Connect

    Lee, R.G.; Hill, T.C.; Holman, B.L.; Uren, R.; Clouse, M.E.

    1982-12-01

    N-isopropyl (/sup 123/I) p-iodoamphetamine (IMP), which is extracted by the brain in proportion to regional blood flow, has been shown to be useful with single-photon emission tomography (SPECT) in the assessment of pathologic states related to blood flow. Because emission tomographic equipment is not yet available at most hospitals, the authors compared IMP brain images obtained with an Anger camera with those obtained by SPECT to determine the usefulness of IMP scintigraphy. Thirty-nine pairs of studies were performed on 12 control patients, 14 patients with stroke, three patients with tumors, and a miscellaneous group of eight patients. Planar scintigraphy showed good correlation with SPECT in determining the presence or absence of abnormality in all patients except one with a very small brain stem infarction that was not detected by planar imaging. Anger images showed poor contrast resolution compared with SPECT images. It is thus expected that SPECT will result in better lesion detection when smaller lesions are studied. Planar scintigraphy is not capable of providing quantitative measurement of regional cerebral blood flow.

  1. Comparison of N-isopropyl (I-123) p-iodoamphetamine brain scans using Anger camera scintigraphy and single-photon emission tomography

    SciTech Connect

    Lee, R.G.; Hill, T.C.; Holman, B.L.; Uren, R.; Clouse, M.E.

    1982-12-01

    N-isopropyl (I-123) p-iodoamphetamine (IMP), which is extracted by the brain in proportion to regional blood flow, has been shown to be useful with single-photon emission tomography (SPECT) in the assessment of pathologic states related to blood flow. Because emission tomographic equipment is not yet available at most hospitals, the authors compared IMP brain images obtained with an Anger camera with those obtained by SPECT to determine the usefulness of IMP scintigraphy. Thirty-nine pairs of studies were performed on 12 control patients, 14 patients with stroke, three patients with tumors, and a miscellaneous group of eight patients. Planar scintigraphy showed good correlation with SPECT in determining the presence or absence of abnormality in all patients except one with a very small brain stem infarction that was not detected by planar imaging. Anger images showed poor contrast resolution compared with SPECT images. It is thus expected that SPECT will result in better lesion detection when smaller lesions are studied. Planar scintigraphy is not capable of providing quantitative measurement of regional cerebral blood flow.

  2. Bone Grafts

    MedlinePlus

    A bone graft transplants bone tissue. Surgeons use bone grafts to repair and rebuild diseased bones in your hips, knees, spine, and sometimes other bones and joints. Grafts can also repair bone loss caused by some ...

  3. Bone tumor

    MedlinePlus

    Tumor - bone; Bone cancer; Primary bone tumor; Secondary bone tumor ... The cause of bone tumors is unknown. They often occur in areas of the bone that grow rapidly. Possible causes include: Genetic defects ...

  4. Myocardial perfusion scintigraphy: the evidence.

    PubMed

    Underwood, S R; Anagnostopoulos, C; Cerqueira, M; Ell, P J; Flint, E J; Harbinson, M; Kelion, A D; Al-Mohammad, A; Prvulovich, E M; Shaw, L J; Tweddel, A C

    2004-02-01

    This review summarises the evidence for the role of myocardial perfusion scintigraphy (MPS) in patients with known or suspected coronary artery disease. It is the product of a consensus conference organised by the British Cardiac Society, the British Nuclear Cardiology Society and the British Nuclear Medicine Society and is endorsed by the Royal College of Physicians of London and the Royal College of Radiologists. It was used to inform the UK National Institute of Clinical Excellence in their appraisal of MPS in patients with chest pain and myocardial infarction. MPS is a well-established, non-invasive imaging technique with a large body of evidence to support its effectiveness in the diagnosis and management of angina and myocardial infarction. It is more accurate than the exercise ECG in detecting myocardial ischaemia and it is the single most powerful technique for predicting future coronary events. The high diagnostic accuracy of MPS allows reliable risk stratification and guides the selection of patients for further interventions, such as revascularisation. This in turn allows more appropriate utilisation of resources, with the potential for both improved clinical outcomes and greater cost-effectiveness. Evidence from modelling and observational studies supports the enhanced cost-effectiveness associated with MPS use. In patients presenting with stable or acute chest pain, strategies of investigation involving MPS are more cost-effective than those not using the technique. MPS also has particular advantages over alternative techniques in the management of a number of patient subgroups, including women, the elderly and those with diabetes, and its use will have a favourable impact on cost-effectiveness in these groups. MPS is already an integral part of many clinical guidelines for the investigation and management of angina and myocardial infarction. However, the technique is underutilised in the UK, as judged by the inappropriately long waiting times and by

  5. Planar plasmonic chiral nanostructures.

    PubMed

    Zu, Shuai; Bao, Yanjun; Fang, Zheyu

    2016-02-21

    A strong chiral optical response induced at a plasmonic Fano resonance in a planar Au heptamer nanostructure was experimentally and theoretically demonstrated. The scattering spectra show the characteristic narrow-band feature of Fano resonances for both left and right circular polarized lights, with a chiral response reaching 30% at the Fano resonance. Specifically, we systematically investigate the chiral response of planar heptamers with gradually changing the inter-particle rotation angles and separation distance. The chiral spectral characteristics clearly depend on the strength of Fano resonances and the associated near-field optical distributions. Finite element method simulations together with a multipole expansion method demonstrate that the enhanced chirality is caused by the excitation of magnetic quadrupolar and electric toroidal dipolar modes. Our work provides an effective method for the design of 2D nanostructures with a strong chiral response. PMID:26818746

  6. Planar electrochemical device assembly

    DOEpatents

    Jacobson; Craig P. , Visco; Steven J. , De Jonghe; Lutgard C.

    2010-11-09

    A pre-fabricated electrochemical device having a dense electrolyte disposed between an anode and a cathode preferably deposited as thin films is bonded to a porous electrically conductive support. A second porous electrically conductive support may be bonded to a counter electrode of the electrochemical device. Multiple electrochemical devices may be bonded in parallel to a single porous support, such as a perforated sheet to provide a planar array. Planar arrays may be arranged in a stacked interconnected array. A method of making a supported electrochemical device is disclosed wherein the method includes a step of bonding a pre-fabricated electrochemical device layer to an existing porous metal or porous metal alloy layer.

  7. Dielectric Covered Planar Antennas

    NASA Technical Reports Server (NTRS)

    Llombart Juan, Nuria (Inventor); Lee, Choonsup (Inventor); Chattopadhyay, Goutam (Inventor); Gill, John J. (Inventor); Skalare, Anders J. (Inventor); Siegel, Peter H. (Inventor)

    2014-01-01

    An antenna element suitable for integrated arrays at terahertz frequencies is disclosed. The antenna element comprises an extended spherical (e.g. hemispherical) semiconductor lens, e.g. silicon, antenna fed by a leaky wave waveguide feed. The extended spherical lens comprises a substantially spherical lens adjacent a substantially planar lens extension. A couple of TE/TM leaky wave modes are excited in a resonant cavity formed between a ground plane and the substantially planar lens extension by a waveguide block coupled to the ground plane. Due to these modes, the primary feed radiates inside the lens with a directive pattern that illuminates a small sector of the lens. The antenna structure is compatible with known semiconductor fabrication technology and enables production of large format imaging arrays.

  8. Planar electrochemical device assembly

    DOEpatents

    Jacobson, Craig P.; Visco, Steven J.; De Jonghe, Lutgard C.

    2007-06-19

    A pre-fabricated electrochemical device having a dense electrolyte disposed between an anode and a cathode preferably deposited as thin films is bonded to a porous electrically conductive support. A second porous electrically conductive support may be bonded to a counter electrode of the electrochemical device. Multiple electrochemical devices may be bonded in parallel to a single porous support, such as a perforated sheet to provide a planar array. Planar arrays may be arranged in a stacked interconnected array. A method of making a supported electrochemical device is disclosed wherein the method includes a step of bonding a pre-fabricated electrochemical device layer to an existing porous metal or porous metal alloy layer.

  9. Planar triode pulser socket

    DOEpatents

    Booth, R.

    1994-10-25

    A planar triode is mounted in a PC board orifice by means of a U-shaped capacitor housing and anode contact yoke removably attached to cathode leg extensions passing through and soldered to the cathode side of the PC board by means of a PC cathode pad. A pliant/flexible contact attached to the orifice make triode grid contact with a grid pad on the grid side of the PC board, permitting quick and easy replacement of bad triodes. 14 figs.

  10. Planar triode pulser socket

    DOEpatents

    Booth, Rex

    1994-01-01

    A planar triode is mounted in a PC board orifice by means of a U-shaped capacitor housing and anode contact yoke removably attached to cathode leg extensions passing through and soldered to the cathode side of the PC board by means of a PC cathode pad. A pliant/flexible contact attached to the orifice make triode grid contact with a grid pad on the grid side of the PC board, permitting quick and easy replacement of bad triodes.

  11. Planar waveguide optical immunosensors

    NASA Astrophysics Data System (ADS)

    Choquette, Steven J.; Locascio-Brown, Laurie E.; Durst, Richard A.

    1991-03-01

    Monoclonal antibodies were covalently bonded to the surfaces of planar waveguides to confer immunoreacth''ity. Silver-ion diffused waveguides were used to measure theophylline concentrations in a fluorescence immunoassay and silicon nitride waveguides were used to detect theophylline in an absorbance-based immunoassay. Liposomes were employed in both assays as the optically detectable label in a competitive reaction to monitor antigen-antibody complexation. Regeneration of the active antibody site will be discussed.

  12. Radionuclide bone imaging in spondylolysis of the lumbar spine in children

    SciTech Connect

    Gelfand, M.J.; Strife, J.L.; Kereiakes, J.G.

    1981-07-01

    Bone scintigraphy and radiography were performed in seven children with back pain. Six of the children with radiographic evidence of a pars interarticularis defect also had abnormal scintigrams. Increased uptake of the bone imaging agent occurred at six of the ten sites of radiographic pars interarticularis defects, implying increased bone metabolic activity. However, the location of scintigraphic abnormalities did not correspond to the location of radiographic abnormalities in several cases. Measurements of absorbed radiation dose indicate that plain radiography, including oblique views where appropriate, has a lower absorbed radiation dose than scintigraphy or tomography and should be performed prior to these studies.

  13. Scintigraphic Evaluation of the Stump Region After Extremity Amputation and the Effect of Scintigraphy on Treatment

    PubMed Central

    Sadic, Murat; Atilgan, Hasan Ikbal; Baskin, Aylin; Cinar, Alev; Koca, Gokhan; Demirel, Koray; Comak, Aylin; Ozyurt, Sinem; Yildirim, Sule; Korkmaz, Meliha

    2016-01-01

    Background We evaluated the stump region with scintigraphy and compared the correlation of treatment modalities and scintigraphic results. Methods Sixty-eight cases with extremity amputation were included in the study. Amputation applied cases underwent four-phase Tc-99m hydroxymethylene diphosphonate scintigraphy. Groups were performed according to the scanning time after amputation and amputation regions. After scintigraphic evaluation, results were recorded into five groups: osteomyelitis, soft-tissue infection, reactive changes secondary to surgery, chronic osteomyelitis, and normal. Post-surgical treatment modalities of the patients were determined and compared with scintigraphic results. Results In the scintigraphic evaluation of stump regions of the 68 amputated cases, 34 patients had acute osteomyelitis, one had chronic osteomyelitis, 16 had soft-tissue infection, and eight had changes secondary to the surgery. Nine of 68 cases had normal scintigraphic features. In the scintigraphic evaluation, 43 patients took antibiotic treatment and 16 had surgery. There was a strong correlation between scintigraphic results and treatment approach (P < 0.0001, r = 0.803) by means of preferred therapy and effectiveness of the therapy according to the scintigraphic results. Scintigraphy need increases with age after amputation and a negative correlation between patient age and scintigraphic need was found (P < 0.02, r = -0.339). There was no pathology in the follow-up in the cases that were scintigraphically normal. Conclusion Bone scintigraphy is a cost-effective, non-invasive, and efficient method that directs treatment in the evaluation of the stump region after amputation. PMID:26858796

  14. Serendipitous finding of transitional cell carcinoma of the kidney on bone and gallium imaging

    SciTech Connect

    Moreno, A.J.; Toney, M.A.; Griffith, J.C.; Rodriguez, A.A.; Turnbull, G.L. )

    1991-03-01

    A 50-year-old woman presented with low back pain. Bone scintigraphy showed a focus of increased activity in the upper pole of the left kidney. Subsequent Ga-67 citrate scintigraphy demonstrated this same abnormal focus as a region of increased activity. Ultrasonography showed a renal mass in the upper pole of the left kidney. At surgery a transitional cell carcinoma of the upper pole of the left kidney was found.

  15. Radioiodine therapy of hyperthyroidism precludes thallium-201 myocardial scintigraphy

    SciTech Connect

    Orzel, J.A.; Kruyer, W.B.; Borchert, R.D.

    1987-02-01

    The authors attempted to perform Tl-201 myocardial perfusion scintigraphy in a 42-year-old man 23 and 35 days after he received 9.8 mCi of oral I-131 for documented Graves' disease. Interference from primary and scattered photons from residual thyroid I-131 made Tl-201 myocardial scintigraphy technically impossible. A series of phantom and patient studies using I-131 and Tl-201 were performed, yielding guidelines for planning Tl-201 myocardial scintigraphy following radioiodine therapy.

  16. Adenosine thallium 201 myocardial perfusion scintigraphy

    SciTech Connect

    Verani, M.S. )

    1991-07-01

    Pharmacologic coronary vasodilation as an adjunct to myocardial perfusion imaging has become increasingly important in the evaluation of patients with coronary artery disease, in view of the large number of patients who cannot perform an adequate exercise test or in whom contraindications render exercise inappropriate. Adenosine is a very potent coronary vasodilator and when combined with thallium 201 scintigraphy produces images of high quality, with the added advantages of a very short half-life (less than 10 seconds) and the ability to adjust the dose during the infusion, which may enhance safety and curtail the duration of side effects. The reported sensitivity and specificity of adenosine thallium 201 scintigraphy for the detection of coronary artery disease are high and at least comparable with imaging after exercise or dipyridamole administration. 23 refs.

  17. Effects of irradiation on mandibular scintigraphy

    SciTech Connect

    Aitasalo, K.; Ruotsalainen, P.

    1985-11-01

    Technetium-99m methylene diphosphonate (Sn) scintigraphy with computer analysis was used to investigate alterations in the pathophysiology of the normal mandible and the pathologic mandible during and after irradiation. Slight but significant elevations of uptake levels were recorded as an early effect of irradiation. The elevations correlated with the duration of treatment and normalized over a follow-up period of 6 to 12 mo. Increased mandibular metabolism was found during irradiation and in osteomyelitis and osteoradionecrosis of the mandible. Scintigraphy with computer analysis proved a simple and valid method in the evaluation of early irradiation damage and pathophysiologic conditions of the mandible. The method can also be used to predict whether the irradiation damage will become irreversible.

  18. Role of scintigraphy in urinary tract infection

    SciTech Connect

    Conway, J.J.

    1988-10-01

    There is controversy regarding the role of radiological imaging for urinary tract infection (UTI). The gold standard has been the intravenous pyelogram (IVP). Yet, the IVP has a very limited value with only about 25% of children with pyelonephritis demonstrating abnormalities. Ultrasound (US) has recently been advocated as a replacement for the poorly sensitive and poorly specific IVP. However, comparative studies between US and IVP indicate only an equivalent sensitivity and specificity. Cortical scintigraphy with Technetium-99m glucoheptonate (99mTc GH) or 99mTc dimercaptosuccinic acid (99mTc DMSA) has also been advocated as a means of differentiating parenchymal (pyelonephritis) from nonparenchymal (lower UTI) involvement in UTI. The clinical presentation may be misleading especially in the infant and child in whom an elevated temperature, flank pain, shaking chills, or an elevated sedimentation rate are often lacking. The clinician attempts to localize the site of infection for it has a direct bearing upon the therapy. A collecting system infection can often be eradicated with a single oral dose of an appropriate antibiotic, whereas renal parenchymal involvement requires IV therapy for an extended interval. Cortical scintigraphy can localize the site of infection with a high degree of accuracy. Recent studies report a sensitivity of 86% and specificity of 81% of pyelonephritis. This is in contrast to the IVP with a sensitivity of only 24% and US with a sensitivity of only 42%. The scintigraphic appearance of parenchymal infection of the kidney is a spectrum of minimal to gross defects reflecting the degree of histologic involvement that spans from a mild infection to frank abscess. Cortical scintigraphy can be used to monitor the evolution of scarring following infection. Cortical scintigraphy with 99mTc DMSA or 99mTc GH is the method of choice for the initial evaluation of UTI. 37 references.

  19. Biliary atresia and neonatal hepatobiliary scintigraphy

    SciTech Connect

    Wynchank, S.; Guillet, J.; Leccia, F.; Soubiran, G.; Blanquet, P.

    1984-03-01

    Hepatobiliary scintigraphy using Tc-99m diethyl IDA was performed on 14 jaundiced neonates. It aided greatly the differential diagnosis between neonatal hepatitis and biliary atresia. Limitations in the interpretation of the results are described, as neonatal hepatitis may be accompanied by biliary excretion ranging from zero to normal. Also both biliary atresia (intra- and extrahepatic) and neonatal hepatitis may show no biliary excretion within 24 hours.

  20. Bone Diseases

    MedlinePlus

    ... avoid smoking and drinking too much alcohol. Bone diseases can make bones easy to break. Different kinds ... break Osteogenesis imperfecta makes your bones brittle Paget's disease of bone makes them weak Bones can also ...

  1. Vertebral hyperemia associated with bone marrow insult and recovery

    SciTech Connect

    Klein, H.A.; Bolden, R.O.; Simone, F.J.

    1984-06-01

    A 15-year-old boy with rhabdoid sarcoma received chemotherapy, which was followed by bone marrow depression, massive nosebleeds and, finally, hematologic recovery. On both hepatobiliary and renal scintigraphy, prominent vertebral activity was present in early images. Correlation with his clinical course suggests that the findings reflect hyperemia due to marrow insult and recovery. Radionuclide imaging to detect hyperemia may be a useful probe for drug effects on hematopoietic bone marrow.

  2. [Skeletal scintigraphy in diseases of the psoriasiform group. A study in 182 patients].

    PubMed

    Altmeyer, P; Holzmann, H; Buhles, N; Hör, G

    1987-11-01

    Bone scintigraphy using 99mTc-EHDP was carried out in 147 psoriatics of both sexes and in 35 nonpsoriatic patients. The psoriatics were subdivided into four groups according to clinical aspects: psoriasis vulgaris (Pv, n = 55), psoriasis inversa (Pinv, n = 32), psoriasis pustulosa of the Königsbeck-Barber type (PpK-B, n = 28), and pustulosis palmaris et plantaris (Ppp, n = 32). The following frequencies of joint involvement were found in the different groups: Pv = 18.3%; Pinv = 22.6%, PpK-B = 11.1%; Ppp = 12.5%; control group 2.3%. In patients suffering from psoriasis vulgaris and psoriasis inversa a pathologic preferential radionuclide uptake was demonstrated in the small peripheral joints of the hands and fingers. The characteristic psoriatic pattern with axial and transverse joint involvement was found in all groups of psoriatic patients. No correlation could be proved between age and pathologic accumulation of the radionuclide or between duration of psoriasis and joint involvement. The so-called anterior chest wall syndrome was found in all patients, but predominantly in those with psoriasis palmaris et plantaris. Finally the indications for bone scintigraphy are discussed. PMID:2962969

  3. Quantitative scintigraphy: Relation to unperfused volume at necropsy, immediately and 1 week after coronary occlusion

    SciTech Connect

    Goodenday, L.S.; Wilkerson, R.D.; Leighton, R.F.; Muswick, G.J.; Hire, N.E.; Nelson, A.D.; Brewster, P.; Yasnoff, W.A.

    1985-05-01

    Interventions such as thrombolytic therapy, designed to preserve jeopardized myocardium after coronary thrombosis, suffer from inadequate scientific validation because of present limitations in the ability to measure the cardiac volume at risk initially, or to predict the eventual volume of unperfused tissue in the absence of intervention. To determine whether the unimpeded change in perfused myocardial volume over time could be predicted accurately in vivo, Tl-201 quantitative scintigraphy was performed in 10 dogs at 5 minutes and at 1 week after closed-chest coronary artery occlusion (CAO). Initial and final ischemic cardiac volumes (ICV) were measured at necropsy by autoradiography: Initial ICV from Ce-141 microspheres injected into the left ventricle 5 minutes after CAO and final ICV from autoradiography of Tl-201 given 1 week after CAO. Planar scintigrams were computer-analyzed with a quantitative anatomically-referenced technique. Early scintigraphic perfusion defect (SPD) size was closely related to initial ICV measured at necropsy, r=.93. SPD size decreased predictably by 50% during 1 week. Late SPD size correlated with final ICV at necropsy, r=.92. Size of the SPD 5 minutes after CAO predicted both size of the SPD 1 week later, r=.87, and also final ICV, r=.92. These data demonstrate that: 1) after acute canine CAO without therapeutic intervention, SPD size becomes predictably smaller with time; 2) this change reflects a change in the volume of ischemic myocardium; 3) quantitative scintigraphy accurately predicts both early and late ischemic cardiac volume as confirmed at autopsy.

  4. Planar elliptic growth

    SciTech Connect

    Mineev, Mark

    2008-01-01

    The planar elliptic extension of the Laplacian growth is, after a proper parametrization, given in a form of a solution to the equation for areapreserving diffeomorphisms. The infinite set of conservation laws associated with such elliptic growth is interpreted in terms of potential theory, and the relations between two major forms of the elliptic growth are analyzed. The constants of integration for closed form solutions are identified as the singularities of the Schwarz function, which are located both inside and outside the moving contour. Well-posedness of the recovery of the elliptic operator governing the process from the continuum of interfaces parametrized by time is addressed and two examples of exact solutions of elliptic growth are presented.

  5. Planar electroluminescent panel techniques

    NASA Technical Reports Server (NTRS)

    Kerr, C.; Kell, R. E.

    1973-01-01

    Investigations of planar electroluminescent multipurpose displays with latch-in memory are described. An 18 x 24 in. flat, thin address panel with elements spacing of 0.100 in. was constructed which demonstrated essentially uniform luminosity of 3-5 foot lamberts for each of its 43200 EL cells. A working model of a 4-bit EL-PC (electroluminescent photoconductive) electrooptical decoder was made which demonstrated the feasibility of this concept. A single-diagram electroluminescent display device with photoconductive-electroluminescent latch-in memory was constructed which demonstrated the conceptual soundness of this principle. Attempts to combine these principles in a single PEL multipurpose display with latch-in memory were unsuccessful and were judged to exceed the state-of-the-art for close-packed (0.10 in. centers) photoconductor-electroluminescent cell assembly.

  6. Flare phenomenon following gefitinib treatment of lung adenocarcinoma with bone metastasis.

    PubMed

    Hashisako, Mikiko; Wakamatsu, Kentarou; Ikegame, Satoshi; Kumazoe, Hiroyuki; Nagata, Nobuhiko; Kajiki, Akira

    2012-01-01

    The skeleton is the most common site for distant metastasis in patients with cancer. To detect bone metastasis and evaluate the efficacy of treatment, we usually use bone scintigraphy and check serum alkaline phosphatase (ALP). However, such evaluation is sometimes difficult due to flare phenomenon. A 61-year-old male was referred to our department with a suspected diagnosis of lung cancer. Following thorough examinations, he was diagnosed with primary lung cancer (adenocarcinoma, Stage IV) and found to have a mutation in the epidermal growth factor receptor gene at exon 21 (L858R). After initiating treatment with oral gefitinib, ALP increased and peaked at 3,592 U/L by 3 weeks and decreased thereafter. At 4 weeks following treatment initiation, bone scintigraphy revealed a marked increase in abnormal accumulation of (99m)Tc-polyphosphate, but the primary tumor and metastases in regions other than the bone were reduced. At 9 weeks after treatment initiation, abnormal accumulations was improved in bone scintigraphy, and computed tomography revealed osteoblastic changes consistent with the accumulated lesion observed by bone scintigraphy. After initiating cancer treatment for bone metastasis, it is not uncommon to observe transient asynchronous accumulation in bone scintigraphy or transient increases in ALP in patients who ultimately respond to the treatment. These changes are called flare phenomenon, and documented in patients with prostate cancer or breast cancer receiving treatment. When determining the efficacy of treatments that target carcinomas with bone metastases, it is important to note that flare phenomenon is often indistinguishable from disease progression indicators. PMID:23036980

  7. Frontal and orbital bone infarctions causing periorbital swelling in patients with sickle cell anemia

    SciTech Connect

    Garty, I.; Koren, A.; Garzozi, H.

    1984-10-01

    Two cases of unilateral and bilateral periorbital hematomas occurred in patients with sickle cell anemia. The cause of periorbital swelling in these cases was found to be orbital and frontal bone infarctions, respectively, diagnosed by technetium Tc 99m medronate bone scintigraphy. To our knowledge, periorbital bone infarction, as a part of the differential diagnosis of periorbital hematoma and as part of the possible ocular manifestations in patients with sickle cell anemia, has not previously been described.

  8. Extraosseous accumulation of bone scan tracer (99m)Tc-methylene diphosphonate in a phlebolith.

    PubMed

    Kulkarni, Mukta; Agrawal, Archi; Zade, Anand; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2012-01-01

    Uptake in non-osseous, non-urologic tissues is occasionally found in the performance of bone scintigraphy. These uptakes reflect an atypical interaction between the radiopharmaceutical and the patient. Knowledge of the rare extraskeletal uptakes and their clinical relevance helps in better interpretation of bone scans. We report an unusual occurrence of extraosseous accumulation of (99m)Tc-methylene diphosphonate in a phlebolith in bone scan, confirmed with the aid of photon emission computed tomography and computed tomography. PMID:23599599

  9. Extraosseous accumulation of bone scan tracer 99mTc-methylene diphosphonate in a phlebolith

    PubMed Central

    Kulkarni, Mukta; Agrawal, Archi; Zade, Anand; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2012-01-01

    Uptake in non-osseous, non-urologic tissues is occasionally found in the performance of bone scintigraphy. These uptakes reflect an atypical interaction between the radiopharmaceutical and the patient. Knowledge of the rare extraskeletal uptakes and their clinical relevance helps in better interpretation of bone scans. We report an unusual occurrence of extraosseous accumulation of 99mTc-methylene diphosphonate in a phlebolith in bone scan, confirmed with the aid of photon emission computed tomography and computed tomography. PMID:23599599

  10. Bone Diseases

    MedlinePlus

    ... also avoid smoking and drinking too much alcohol. Bone diseases can make bones easy to break. Different kinds ... Bones can also develop cancer and infections Other bone diseases, which are caused by poor nutrition, genetics, or ...

  11. Bone Grafts

    MedlinePlus

    ... repair and rebuild diseased bones in your hips, knees, spine, and sometimes other bones and joints. Grafts can also repair bone loss caused by some types of fractures or cancers. Once your body accepts the bone ...

  12. Electrochemical planarization for microelectronic circuits

    SciTech Connect

    Contolini, R.J.; Mayer, S.T.; Bernhardt, A.F.

    1993-03-25

    The need for flatter and smoother surfaces (planarization) in microelectronic circuits increases as the number of metal levels in ultra large scale integrated (ULSI) circuits increases. At Lawrence Livermore National Laboratory, the authors have developed an electrochemical planarization process that fills vias and trenches with metal (without voids) and subsequently planarizes the surface. Use is made of plasma-enhanced chemical vapor deposition (PECVD) of SiO[sub 2] for the dielectric layers and electroplated copper for the metalization. This report describes the advantages of this process over existing techniques, possibilities for collaboration, and previous technology transfer.

  13. Electrochemical planarization for microelectronic circuits

    NASA Astrophysics Data System (ADS)

    Contolini, R. J.; Mayer, S. T.; Bernhardt, A. F.

    1993-03-01

    The need for flatter and smoother surfaces (planarization) in microelectronic circuits increases as the number of metal levels in ultra large scale integrated (ULSI) circuits increases. At Lawrence Livermore National Laboratory, the authors have developed an electrochemical planarization process that fills vias and trenches with metal (without voids) and subsequently planarizes the surface. Use is made of plasma-enhanced chemical vapor deposition (PECVD) of SiO2 for the dielectric layers and electroplated copper for the metalization. This report describes the advantages of this process over existing techniques, possibilities for collaboration, and previous technology transfer.

  14. Non-planar chemical preconcentrator

    DOEpatents

    Manginell, Ronald P.; Adkins, Douglas R.; Sokolowski, Sara S.; Lewis, Patrick R.

    2006-10-10

    A non-planar chemical preconcentrator comprises a high-surface area, low mass, three-dimensional, flow-through sorption support structure that can be coated or packed with a sorptive material. The sorptive material can collect and concentrate a chemical analyte from a fluid stream and rapidly release it as a very narrow temporal plug for improved separations in a microanalytical system. The non-planar chemical preconcentrator retains most of the thermal and fabrication benefits of a planar preconcentrator, but has improved ruggedness and uptake, while reducing sorptive coating concerns and extending the range of collectible analytes.

  15. Hepatobiliary scintigraphy in a patient with bilhemia.

    PubMed

    François, D; Walrand, S; Van Nieuwenhuyse, J P; de Ville de Goyet, J; Pauwels, S

    1994-09-01

    A 4-year-old child referred for acute jaundice following percutaneous needle biopsy of the liver underwent hepatobiliary scintigraphy. Although all conventional liver tests suggested preservation of hepatocyte function, the tracer uptake in the liver appeared dramatically reduced at scintigraphy and the blood pool activity did not decrease significantly until the end of the study. Visualization of the bile ducts indicated, however, that the tracer was taken up by the hepatocyte and further excreted into the biliary tree. There was no tracer pooling in the biliary tree although no bowel activity was observed, even on delayed images. The association of persistent blood pool activity, bile duct visualization without tracer pooling, and nonvisualization of the bowel was caused by a continuous recirculation of the tracer from the biliary tree into the bloodstream. The presence of a biliovenous fistula was further proven by percutaneous transhepatic cholangiography performed 24 h later. Since 1975, only 16 cases of bilhemia have been reported. To the best of our knowledge the scintigraphic pattern of this rare but life-threatening complication has not previously been reported. PMID:7995281

  16. Comparison of SPECT/CT and planar MIBI in terms of operating time and cost in the surgical management of primary hyperparathyroidism.

    PubMed

    Setabutr, Dhave; Vakharia, Kavita; Nogan, Stephen J; Kamel, George N; Allen, Thomas; Saunders, Brian D; Goldenberg, David

    2015-01-01

    We conducted a retrospective study to compare operating times and costs in patients who underwent guided parathyroidectomies with either (1) technetium-99m ((99m)Tc) multiplex ion-beam imaging (MIBI) parathyroid scintigraphy with single-photon emission computed tomography/computed tomography (SPECT/CT) fusion images or (2) sestamibi dual-phase (99m)Tc MIBI planar parathyroid scintigraphy alone preoperatively. Our study population was made up of the first 24 patients at our facility who had undergone SPECT/CT parathyroid imaging with technetium-99m ((99m)Tc) MIBI and a group of 24 patients who had undergone MIBI planar imaging alone. Patient demographics, preoperative laboratory test results, operating times, and hospital charges were analyzed. We found that less operating time was required for the planar MIBI group than in the SPECT/CT group (mean: 135 vs. 158 min), although the difference was not statistically significant. Likewise, the total cost of treatment was lower in the planar MIBI group (mean: $10,035 vs. $11,592); the difference was statistically significant by one measure (p × 0.02, Wilcoxon rank sum test) but not by another (p × 0.06, Student t test). Although SPECT/CT is efficient for patients with small and difficult-to-localize adenomas, it has yet to demonstrate greater efficacy or cost-effectiveness than planar MIBI for routine parathyroidectomy in patients with primary hyperparathyroidism when an easily identifiable parathyroid adenoma is localized. PMID:26535821

  17. Process for forming planarized films

    DOEpatents

    Pang, Stella W.; Horn, Mark W.

    1991-01-01

    A planarization process and apparatus which employs plasma-enhanced chemical vapor deposition (PECVD) to form plarnarization films of dielectric or conductive carbonaceous material on step-like substrates.

  18. Object Classification via Planar Abstraction

    NASA Astrophysics Data System (ADS)

    Oesau, Sven; Lafarge, Florent; Alliez, Pierre

    2016-06-01

    We present a supervised machine learning approach for classification of objects from sampled point data. The main idea consists in first abstracting the input object into planar parts at several scales, then discriminate between the different classes of objects solely through features derived from these planar shapes. Abstracting into planar shapes provides a means to both reduce the computational complexity and improve robustness to defects inherent to the acquisition process. Measuring statistical properties and relationships between planar shapes offers invariance to scale and orientation. A random forest is then used for solving the multiclass classification problem. We demonstrate the potential of our approach on a set of indoor objects from the Princeton shape benchmark and on objects acquired from indoor scenes and compare the performance of our method with other point-based shape descriptors.

  19. Does aspiration of bones and joints affect results of later bone scanning

    SciTech Connect

    Canale, S.T.; Harkness, R.M.; Thomas, P.A.; Massie, J.D.

    1985-01-01

    To determine the effect, if any, of needle aspiration on /sup 99m/Tc bone scanning, three different areas of 15 dogs were first aspirated and then imaged with technetium bone scintigraphy. The hip joint was aspirated, the distal femoral metaphysis was drilled and aspirated, and the tibial periosteum was scraped with an 18- or 20-gauge needle. Varying amounts of trauma were inflicted to simulate varying difficulties at aspiration. /sup 99m/Tc bone scans were obtained from 5 h to 10 days later. There was no evidence of focal technetium uptake after any hip joint aspiration. This was consistent regardless of the amount of trauma inflicted or the time from aspiration to bone scanning. Metaphyseal cortical drilling and tibial periosteal scraping occasionally caused some focal uptake when scanning was delayed greater than 2 days. When osteomyelitis or pyarthrosis is clinically suspected, joint aspiration can be performed without fear of producing a false- positive bone scan.

  20. Flat panel planar optic display

    SciTech Connect

    Veligdan, J.T.

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  1. Extramedullary Soft Tissue Involvement and Discrepant Osseous Uptake on Tc-99m MDP and Ga-67 Citrate Scintigraphy in a Patient With Multiple Myeloma

    PubMed Central

    Tsai, Szu-Ying; Wang, Shan-Ying; Shiau, Yu-Chien; Wu, Yen-Wen

    2015-01-01

    Abstract Multiple myeloma (MM) is a plasma cell neoplasm with skeletal destruction which could also spread to extramedullary regions. Common diagnostic imaging modalities include skeletal radiography, computed tomography (CT), magnetic resonance imaging (MRI). Recently, PET/CT is proposed as an ideal tomographic tool for diagnosis and follow-up, but impending factors includes high cost, limited availability of cameras and radiotracers. Bone scan and gallium scan are usually considered of limited clinical value. Herein, we present a 66-year-old Taiwanese man with MM, who was hospitalized to our hospital for bone pain control. Bone and gallium scintigraphies were obtained for bone pain and infection workup. However, unexpected features of discordant osseous uptake with high gallium-to-bone uptake ratio and extramedullary gallium uptake were noted which both indicated poor prognosis of MM. The patient then passed away due to rapid disease progression. In conclusion, although gallium and bone scintigraphies are considered less sensitive for MM, combined use may be a good alternative for 18F-FDG PET/CT in evaluation of disease extent and prognosis, especially in high-risk patients or with suspicion of disease progression.

  2. Radiographic and radionuclide imaging in multiple myeloma: the role of gallium scintigraphy: concise communication

    SciTech Connect

    Waxman, A.D.; Siemsen, J.K.; Levine, A.M.; Holdorf, D.; Suzuki, R.; Singer, F.R.; Bateman, J.

    1981-03-01

    Eighteen patients with multiple myeloma were studied using radiographs of the skeletal system, technetium phosphate bone scans, and gallium-67 scintigraphy. A total of 94 sites were used as the basis for comparison in these 18 patients. Radiographic sensitivity on a patient basis was 94%, and was 82% on a site basis. Bone scans were positive in 78% of patients and in 46% of sites. Gallium scans were positive in 56% of patients and in 40% of sites. In five of the 18 patients, gallium scans showed activity in abnormal sites wth a greater lesion-to-nonlesion ratio than did the bone scan. In this subgroup of patients, the disease was fulminant, and all died within 3 mo of their study. The finding of high gallium uptake in osseous sites that are normal or only slightly abnormal on bone scan has served to identify a subgroup of patients with rapidly progressive disease who may benefit from alternative treatment modalities such as radiation therapy.

  3. Efficacy of coronary artery bypass surgery with gastroepiploic artery. Assessment with thallium 201 myocardial scintigraphy

    SciTech Connect

    Kusukawa, J.; Hirota, Y.; Kawamura, K.; Suma, H.; Takeuchi, A.; Adachi, I.; Akagi, H. )

    1989-09-01

    This study describes the efficacy of the right gastroepiploic artery (GEA) as graft material for coronary artery bypass grafting (CABG) as assessed by exercise thallium 201 myocardial scintigraphy in eight patients (age, 59.4 {plus minus} 9.35 years (mean {plus minus} SD)) who underwent CABG with the GEA graft in the past 2 years. Planar and single-photon-emission computed tomographic (SPECT) images were obtained during and 3 hours after exercise. Planar images were evaluated quantitatively with the percentile-washout method, and SPECT images were evaluated qualitatively with a bull's-eye, polar-coordinate map. All patients had triple-vessel disease, and in situ GEAs were anastomosed to the right coronary artery in seven patients and to the left anterior descending coronary artery in one. The internal mammary artery graft was concomitantly used in all patients. The mean number of grafts per patient was 3.0 (range, 2-4). Preoperative exercise testing could not be performed in two patients because of emergency operation. By qualitative assessment with the polar-coordinate map, four patients showed improvement, one did not show any change, and one became worse due to perioperative myocardial infarction.

  4. Scintigraphy in a patient with complicated osteopetrosis

    SciTech Connect

    Adams, B.K.

    1989-05-01

    Skeletal, reticuloendothelial and renal images were obtained on a patient with osteopetrosis using Tc-99m MDP, Tc-99m HSA millimicrospheres and Tc-99m DTPA respectively. The bone scan showed increased uptake in multiple fracture sites, in the frontal bone, and in the splayed metaphyses of long bones while the remainder of the skeleton appeared normal. Reticuloendothelial images demonstrated an absence of bone marrow activity, hepatosplenomegaly and a site of extramedullary hematopoiesis. A renogram demonstrated a left kidney displaced and distorted by the massive splenomegaly.

  5. Thallium-201 scintigraphy in differentiated thyroid cancer: Comparison with radioiodine scintigraphy and serum thyroglobulin determinations

    SciTech Connect

    Ramanna, L.; Waxman, A.; Braunstein, G. )

    1991-03-01

    The role of thallium-201 ({sup 201}TI) scintigraphy in the follow-up evaluation of differentiated thyroid carcinoma (DTC) is controversial. Desirable characteristics of {sup 201}TI scintigraphy including the potential for no thyroid hormone withdrawal, immediate imaging postinjection, and low radiation burden relative to iodine-131 ({sup 131}I) suggests it is logistically superior to {sup 131}I scintigraphy. Fifty-two patients with DTC were evaluated with {sup 201}TI and {sup 131}I neck and chest images, and serum thyroglobulin measurements. In post-thyroidectomy and pre-{sup 131}I ablation therapy patients, very little {sup 201}TI accumulation was noted within the thyroid bed, with discordantly increased {sup 131}I activity and normal serum thyroglobulin measurements. Twenty-nine percent of patients evaluated after {sup 131}I ablative therapy had elevated serum thyroglobulin levels and localized neck and chest abnormalities on 201TI scan that were not seen on {sup 131}I studies. Our data suggest that {sup 201}TI is more sensitive than {sup 131}I diagnostic (5 mCi) studies for detection of DTC, while {sup 131}I is more sensitive in detecting normal residual thyroid tissue postoperatively.

  6. Useful hepatic parenchymal imaging in hepatobiliary scintigraphy

    SciTech Connect

    Brown, M.L.; Freitas, J.E.; Wahner, H.W.

    1981-05-01

    Hepatobiliary scintigraphy with the /sup 99m/Tc-labeled iminodiacetic acid derivatives has been shown to be useful in the evaluation of biliary tract diseases, especially for the diagnosis of acute cholecystitis. Little emphasis has been placed on the importance of the hepatic parenchymal image that occurs early in the imaging sequence. To determine what information can be obtained from the hepatic parenchymal image, a comparison was carried out of sulfur colloid and iminodiacetic acid images in 50 patients with focal defects. In 46 of 50 patients, the number and position of lesions on the two studies were similar, while in four patients the images were discordant. In addition to being very similar in lesion detection, the iminodiacetic acid scans also allowed more specificity in the later imaging (biliary phase) in 13 cases.

  7. Gallium 67 scintigraphy in glomerular disease

    SciTech Connect

    Bakir, A.A.; Lopez-Majano, V.; Levy, P.S.; Rhee, H.L.; Dunea, G.

    1988-12-01

    To evaluate the diagnostic usefulness of gallium 67 scintigraphy in glomerular disease, 45 patients with various glomerulopathies, excluding lupus nephritis and renal vasculitis, were studied. Persistent renal visualization 48 hours after the gallium injection, a positive scintigram, was graded as + (less than), ++ (equal to), and +++ (greater than) the hepatic uptake. Positive scintigrams were seen in ten of 16 cases of focal segmental glomerulosclerosis, six of 11 cases of proliferative glomerulonephritis, and one case of minimal change, and one of two cases of membranous nephropathy; also in three of six cases of sickle glomerulopathy, two cases of diabetic neuropathy, one of two cases of amyloidosis, and one case of mild chronic allograft rejection. The 25 patients with positive scans were younger than the 20 with negative scans (31 +/- 12 v 42 +/- 17 years; P less than 0.01), and exhibited greater proteinuria (8.19 +/- 7.96 v 2.9 +/- 2.3 S/d; P less than 0.01) and lower serum creatinine values (2 +/- 2 v 4.1 +/- 2.8 mg/dL; P less than 0.01). The amount of proteinuria correlated directly with the intensity grade of the gallium image (P less than 0.02), but there was no correlation between the biopsy diagnosis and the outcome of the gallium scan. It was concluded that gallium scintigraphy is not useful in the differential diagnosis of the glomerular diseases under discussion. Younger patients with good renal function and heavy proteinuria are likely to have a positive renal scintigram regardless of the underlying glomerulopathy.

  8. Planar photovoltaic solar concentrator module

    DOEpatents

    Chiang, Clement J.

    1992-01-01

    A planar photovoltaic concentrator module for producing an electrical signal from incident solar radiation includes an electrically insulating housing having a front wall, an opposing back wall and a hollow interior. A solar cell having electrical terminals is positioned within the interior of the housing. A planar conductor is connected with a terminal of the solar cell of the same polarity. A lens forming the front wall of the housing is operable to direct solar radiation incident to the lens into the interior of the housing. A refractive optical element in contact with the solar cell and facing the lens receives the solar radiation directed into the interior of the housing by the lens and directs the solar radiation to the solar cell to cause the solar cell to generate an electrical signal. An electrically conductive planar member is positioned in the housing to rest on the housing back wall in supporting relation with the solar cell terminal of opposite polarity. The planar member is operable to dissipate heat radiated by the solar cell as the solar cell generates an electrical signal and further forms a solar cell conductor connected with the solar cell terminal to permit the electrical signal generated by the solar cell to be measured between the planar member and the conductor.

  9. Planar photovoltaic solar concentrator module

    DOEpatents

    Chiang, C.J.

    1992-12-01

    A planar photovoltaic concentrator module for producing an electrical signal from incident solar radiation includes an electrically insulating housing having a front wall, an opposing back wall and a hollow interior. A solar cell having electrical terminals is positioned within the interior of the housing. A planar conductor is connected with a terminal of the solar cell of the same polarity. A lens forming the front wall of the housing is operable to direct solar radiation incident to the lens into the interior of the housing. A refractive optical element in contact with the solar cell and facing the lens receives the solar radiation directed into the interior of the housing by the lens and directs the solar radiation to the solar cell to cause the solar cell to generate an electrical signal. An electrically conductive planar member is positioned in the housing to rest on the housing back wall in supporting relation with the solar cell terminal of opposite polarity. The planar member is operable to dissipate heat radiated by the solar cell as the solar cell generates an electrical signal and further forms a solar cell conductor connected with the solar cell terminal to permit the electrical signal generated by the solar cell to be measured between the planar member and the conductor. 5 figs.

  10. Living Bones, Strong Bones

    NASA Video Gallery

    In this classroom activity, engineering, nutrition, and physical activity collide when students design and build a healthy bone model of a space explorer which is strong enough to withstand increas...

  11. Planar immersion lens with metasurfaces

    NASA Astrophysics Data System (ADS)

    Ho, John S.; Qiu, Brynan; Tanabe, Yuji; Yeh, Alexander J.; Fan, Shanhui; Poon, Ada S. Y.

    2015-03-01

    The solid immersion lens is a powerful optical tool that allows light entering material from air or a vacuum to focus to a spot much smaller than the free-space wavelength. Conventionally, however, the lenses rely on semispherical topographies and are nonplanar and bulky, which limits their integration in many applications. Recently, there has been considerable interest in using planar structures, referred to as metasurfaces, to construct flat optical components for manipulating light in unusual ways. Here, we propose and demonstrate the concept of a planar immersion lens based on metasurfaces. The resulting planar device, when placed near an interface between air and dielectric material, can focus electromagnetic radiation incident from air to a spot in the material smaller than the free-space wavelength. As an experimental demonstration, we fabricate an ultrathin and flexible microwave lens and further show that it achieves wireless energy transfer in material mimicking biological tissue.

  12. Bone scan

    MedlinePlus

    ... scan is an imaging test used to diagnose bone diseases and find out how severe they are. How ... a 3-phase bone scan. To evaluate metastatic bone disease, images are taken only after the 3- to ...

  13. Bone Cancer

    MedlinePlus

    Cancer that starts in a bone is uncommon. Cancer that has spread to the bone from another ... more common. There are three types of bone cancer: Osteosarcoma - occurs most often between ages 10 and ...

  14. Bone scan

    MedlinePlus

    A bone scan is an imaging test used to diagnose bone diseases and find out how severe they are. ... A bone scan involves injecting a very small amount of radioactive material (radiotracer) into a vein. The substance travels through ...

  15. Bone Density

    MedlinePlus

    ... bone health. It compares your bone density, or mass, to that of a healthy person who is ... Whether your osteoporosis treatment is working Low bone mass that is not low enough to be osteoporosis ...

  16. Bone Tumor

    MedlinePlus

    ... most common types of primary bone cancer are: • Multiple myeloma. Multiple myeloma is the most common primary bone cancer. It ... Any bone can be affected by this cancer. Multiple myeloma affects approximately six people per 100,000 each ...

  17. Bone Cancer

    MedlinePlus

    Cancer that starts in a bone is uncommon. Cancer that has spread to the bone from another part of the body is more common. There are three types of bone cancer: Osteosarcoma - occurs most often between ages 10 ...

  18. Massive inguinoscrotal herniation of the bladder with ureter: incidental demonstration on bone scan.

    PubMed

    Ilgan, Seyfettin; Ozguven, Mehmet; Emer, Mustafa O; Karacalioglu, Alper O

    2007-08-01

    Inguinoscrotal herniation of the bladder is a rare clinical entity. The condition is often diagnosed incidentally or during the course of surgical repair of inguinal hernias. In a smaller number of cases, bladder hernia can be seen during nuclear medicine studies. We report a rare case of massive inguinoscrotal bladder herniation with ureter, causing urinary stasis on bone scintigraphy. PMID:17705019

  19. Radionuclide bone imaging in spondylolysis of the lumbar spine in children

    SciTech Connect

    Gelfand, M.J.; Strife, J.L.; Kereiakes, J.G.

    1981-07-01

    Bone scintigraphy and radiography were performed in seven children with back pain. Six of the children with radiographic evidence of a pars interarticularis defect also had abnormal scintigrams. Increased uptake of the bone imaging agent occurred at six of the ten sites of radiographic pars interarticularis defects, implying increased bone metabolic activity. However, the location of scintigraphic abnormalities did not correspond to the location of radiographic abnormalities in several cases. Possible explanations for the discordant findings are: (a) normal bone metabolism at the site of an old spondylolysis and (b) radiographically inapparent stress fractures. Measurements of absorbed radiation dose indicate that plain radiography, including oblique views where appropriate, has a lower absorbed radiation dose than scintigraphy or tomography and should be performed prior to these studies.

  20. Renal scintigraphy following angiotensin converting enzyme inhibition in the diagnosis of renovascular hypertension (captopril scintigraphy)

    SciTech Connect

    Sfakianakis, G.N. )

    1989-09-01

    This article describes the pathophysiology and primary causes of renovascular hypertension (RVH). No historical or physical finding is specific in the diagnosis of RVH, although onset of hypertension before the age of 30 years may suggest the possible presence of RVH. The physiology of the kidney is described along with the biochemistry of angiotensin converting enzyme inhibitors. The main thrust of the article is nuclear medicine techniques useful in the diagnosis of this disease. Several diagnositic methods are described but captopril scintigraphy is presented as a method that may give more optimal results in the diagnosis of RVH.

  1. Drummer's fracture of the third metatarsal bone.

    PubMed

    Cusi, Mel; Tsung, Jason; Nouh, Fred; Wong, Louise; Mansberg, Robert; Van der Wall, Hans

    2007-09-01

    A 14-year-old girl presented with a painful right foot. She was an elite water-polo player and could recall no history of specific trauma to the foot. On close and persistent questioning, she admitted to having taken up playing the drums recently, with practice sessions of up to 4 h/d. She used the foot drum with her right foot and had noticed that this was becoming increasingly painful and prevented her playing the instrument for the last 2 days. Plain films of the foot were originally reported as normal, but revised to abnormal after the scintigraphic study. Bone scintigraphy confirmed a stress fracture of the right 3rd metatarsal bone. Stress fractures of the 3rd metatarsal bone are rare with only 2 previous reports in the literature. PMID:17710033

  2. Os trigonum syndrome on bone SPECT/CT.

    PubMed

    Huang, Jianmin; Servaes, Sabah; Zhuang, Hongming

    2014-08-01

    A 16-year-old female athlete presented with increased pain in the distal left lower extremity. A possible stress fracture or shin splint of the left tibia was first considered. A 3-phase bone scintigraphy showed a very small focus of increased activity in the posterior left foot. A diagnosis of os trigonum syndrome was made after SPECT/CT images pinpointed the activity at the left os trigonum. PMID:24686218

  3. Short bones

    MedlinePlus

    Short bones in the human body are often cube-like, their length, width, and height are all about the same. Short bones include the carpal bones of the hands and wrist, and the tarsal bones of the feet and ankles.

  4. Useful hepatic parenchymal imaging in hepatobiliary scintigraphy

    SciTech Connect

    Brown, M.L.; Freitas, J.E.; Wahner, H.W.

    1981-05-01

    Hepatobiliary scintigraphy with the 99mTc-labeled iminodiacetic acid derivatives has been shown to be useful in the evaluation of biliary tract diseases, especially for the diagnosis of acute cholecystitis. Little emphasis has been placed on the importance of the hepatic parenchymal image that occurs early in the imaging sequence. To determine what information can be obtained from the hepatic parenchymal image, a comparison was carried out of sulfur colloid and iminodiacetic acid images in 50 patients with focal defects. In 46 of 50 patients, the number and position of lesions on the two studies were similar, while in four patients the images were discordant. In addition to being very similar in lesion detection, the iminodiacetic acid scans also allowed more specificity in the later imaging (biliary phase) in 13 cases. The value of iminodiacetic acid derivatives in the evaluation of some biliary tract disorders has been established; considerable value can also be obtained by close inspection of the hepatic parenchymal image as well.

  5. Diagnostic value of a new myocardial perfusion agent, teboroxime (SQ 30,217), utilizing a rapid planar imaging protocol: Preliminary results

    SciTech Connect

    Hendel, R.C.; McSherry, B.; Karimeddini, M.; Leppo, J.A. )

    1990-10-01

    Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed.

  6. Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: Preliminary results

    SciTech Connect

    Hendel, R.C.; McSherry, B.; Karimeddini, M.; Leppo, J.A. )

    1990-11-01

    Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxoime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed.

  7. Bone scanning.

    PubMed

    Greenfield, L D; Bennett, L R

    1975-03-01

    Scanning is based on the uptake of a nuclide by the crystal lattice of bone and is related to bone blood flow. Cancer cells do not take up the tracer. Normally, the scan visualizes the highly vascular bones. Scans are useful and are indicated in metastatic bone disease, primary bone tumors, hematologic malignancies and some non-neoplastic diseases. The scan is more sensitive than x-ray in the detection of malignant diseases of the skeleton. PMID:1054210

  8. Manufacturing of planar ceramic interconnects

    SciTech Connect

    Armstrong, B.L.; Coffey, G.W.; Meinhardt, K.D.; Armstrong, T.R.

    1996-12-31

    The fabrication of ceramic interconnects for solid oxide fuel cells (SOFC) and separator plates for electrochemical separation devices has been a perennial challenge facing developers. Electrochemical vapor deposition (EVD), plasma spraying, pressing, tape casting and tape calendering are processes that are typically utilized to fabricate separator plates or interconnects for the various SOFC designs and electrochemical separation devices. For sake of brevity and the selection of a planar fuel cell or gas separation device design, pressing will be the only fabrication technique discussed here. This paper reports on the effect of the characteristics of two doped lanthanum manganite powders used in the initial studies as a planar porous separator for a fuel cell cathode and as a dense interconnect for an oxygen generator.

  9. Planar Multilayer Circuit Quantum Electrodynamics

    NASA Astrophysics Data System (ADS)

    Minev, Z. K.; Serniak, K.; Pop, I. M.; Leghtas, Z.; Sliwa, K.; Hatridge, M.; Frunzio, L.; Schoelkopf, R. J.; Devoret, M. H.

    2016-04-01

    Experimental quantum information processing with superconducting circuits is rapidly advancing, driven by innovation in two classes of devices, one involving planar microfabricated (2D) resonators, and the other involving machined three-dimensional (3D) cavities. We demonstrate that circuit quantum electrodynamics can be implemented in a multilayer superconducting structure that combines 2D and 3D advantages. We employ standard microfabrication techniques to pattern each layer, and rely on a vacuum gap between the layers to store the electromagnetic energy. Planar qubits are lithographically defined as an aperture in a conducting boundary of the resonators. We demonstrate the aperture concept by implementing an integrated, two-cavity-mode, one-transmon-qubit system.

  10. Window defect planar mapping technique

    NASA Technical Reports Server (NTRS)

    Minton, F. R.; Minton, U. O. (Inventor)

    1976-01-01

    A method of planar mapping defects in a window having an edge surface and a planar surface. The method is comprised of steps for mounting the window on a support surface. Then a light sensitive paper is placed adjacent to the window surface. A light source is positioned adjacent to the window edge. The window is then illuminated with the source of light for a predetermined interval of time. Defects on the surface of the glass, as well as in the interior of the glass are detected by analyzing the developed light sensitive paper. The light source must be in the form of optical fibers or a light tube whose light transmitting ends are placed near the edge surface of the window.

  11. Summing Planar Bosonic Open Strings

    SciTech Connect

    Bardakci, Korkut

    2006-02-16

    In earlier work, planar graphs of massless {phi}{sup 3} theory were summed with the help of the light cone world sheet picture and the mean field approximation. In the present article, the same methods are applied to the problem of summing planar bosonic open strings. They find that in the ground state of the system, string boundaries form a condensate on the world sheet, and a new string emerges from this summation. Its slope is always greater than the initial slope, and it remains non-zero even when the initial slope is set equal to zero. If they assume the initial string tends to a field a theory in the zero slope limit, this result provides evidence for string formation in field theory.

  12. Compact planar microwave blocking filters

    NASA Technical Reports Server (NTRS)

    U-Yen, Kongpop (Inventor); Wollack, Edward J. (Inventor)

    2012-01-01

    A compact planar microwave blocking filter includes a dielectric substrate and a plurality of filter unit elements disposed on the substrate. The filter unit elements are interconnected in a symmetrical series cascade with filter unit elements being organized in the series based on physical size. In the filter, a first filter unit element of the plurality of filter unit elements includes a low impedance open-ended line configured to reduce the shunt capacitance of the filter.

  13. Enjoyment of Euclidean planar triangles

    NASA Astrophysics Data System (ADS)

    Srinivasan, V. K.

    2013-09-01

    This article adopts the following classification for a Euclidean planar ?, purely based on angles alone. A Euclidean planar triangle is said to be acute angled if all the three angles of the Euclidean planar ? are acute angles. It is said to be right angled at a specific vertex, say B, if the angle ? is a right angle with the two remaining angles as acute angles. It is said to be obtuse angled at the vertex B if ? is an obtuse angle, with the two remaining angles as acute angles. In spite of the availability of numerous text books that contain our human knowledge of Euclidean plane geometry, softwares can offer newer insights about the characterizations of planar geometrical objects. The author's characterizations of triangles involve points like the centroid G, the orthocentre H of the ?, the circumcentre S of the ?, the centre N of the nine-point circle of the ?. Also the radical centre rc of three involved diameter circles of the sides BC, AC and AB of the ? provides a reformulation of the orthocentre, resulting in an interesting theorem, dubbed by the author as 'Three Circles Theorem'. This provides a special result for a right-angled ?, again dubbed by the author as 'The Four Circles Theorem'. Apart from providing various inter connections between the geometrical points, the relationships between shapes of the triangle and the behaviour of the points are reasonably explored in this article. Most of these results will be useful to students that take courses in Euclidean Geometry at the college level and the high school level. This article will be useful to teachers in mathematics at the high school level and the college level.

  14. PANEL CODE FOR PLANAR CASCADES

    NASA Technical Reports Server (NTRS)

    Mcfarland, E. R.

    1994-01-01

    The Panel Code for Planar Cascades was developed as an aid for the designer of turbomachinery blade rows. The effective design of turbomachinery blade rows relies on the use of computer codes to model the flow on blade-to-blade surfaces. Most of the currently used codes model the flow as inviscid, irrotational, and compressible with solutions being obtained by finite difference or finite element numerical techniques. While these codes can yield very accurate solutions, they usually require an experienced user to manipulate input data and control parameters. Also, they often limit a designer in the types of blade geometries, cascade configurations, and flow conditions that can be considered. The Panel Code for Planar Cascades accelerates the design process and gives the designer more freedom in developing blade shapes by offering a simple blade-to-blade flow code. Panel, or integral equation, solution techniques have been used for several years by external aerodynamicists who have developed and refined them into a primary design tool of the aircraft industry. The Panel Code for Planar Cascades adapts these same techniques to provide a versatile, stable, and efficient calculation scheme for internal flow. The code calculates the compressible, inviscid, irrotational flow through a planar cascade of arbitrary blade shapes. Since the panel solution technique is for incompressible flow, a compressibility correction is introduced to account for compressible flow effects. The analysis is limited to flow conditions in the subsonic and shock-free transonic range. Input to the code consists of inlet flow conditions, blade geometry data, and simple control parameters. Output includes flow parameters at selected control points. This program is written in FORTRAN IV for batch execution and has been implemented on an IBM 370 series computer with a central memory requirement of approximately 590K of 8 bit bytes. This program was developed in 1982.

  15. Planarization of metal films for multilevel interconnects

    DOEpatents

    Tuckerman, D.B.

    1989-03-21

    In the fabrication of multilevel integrated circuits, each metal layer is planarized by heating to momentarily melt the layer. The layer is melted by sweeping laser pulses of suitable width, typically about 1 microsecond duration, over the layer in small increments. The planarization of each metal layer eliminates irregular and discontinuous conditions between successive layers. The planarization method is particularly applicable to circuits having ground or power planes and allows for multilevel interconnects. Dielectric layers can also be planarized to produce a fully planar multilevel interconnect structure. The method is useful for the fabrication of VLSI circuits, particularly for wafer-scale integration. 6 figs.

  16. Planarization of metal films for multilevel interconnects

    DOEpatents

    Tuckerman, D.B.

    1985-08-23

    In the fabrication of multilevel integrated circuits, each metal layer is planarized by heating to momentarily melt the layer. The layer is melted by sweeping laser pulses of suitable width, typically about 1 microsecond duration, over the layer in small increments. The planarization of each metal layer eliminates irregular and discontinuous conditions between successive layers. The planarization method is particularly applicable to circuits having ground or power planes and allows for multilevel interconnects. Dielectric layers can also be planarized to produce a fully planar multilevel interconnect structure. The method is useful for the fabrication of VLSI circuits, particularly for wafer-scale integration.

  17. Planarization of metal films for multilevel interconnects

    DOEpatents

    Tuckerman, D.B.

    1985-06-24

    In the fabrication of multilevel integrated circuits, each metal layer is planarized by heating to momentarily melt the layer. The layer is melted by sweeping lase pulses of suitable width, typically about 1 microsecond duration, over the layer in small increments. The planarization of each metal layer eliminates irregular and discontinuous conditions between successive layers. The planarization method is particularly applicable to circuits having ground or power planes and allows for multilevel interconnects. Dielectric layers can also be planarized to produce a fully planar multilevel interconnect structure. The method is useful for the fabrication of VLSI circuits, particularly for wafer-scale integration.

  18. NMR planar microcoil for microanalysis

    NASA Astrophysics Data System (ADS)

    Sorli, B.; Chateaux, J. F.; Quiquerez, L.; Bouchet-Fakri, L.; Briguet, A.; Morin, P.

    2006-11-01

    This article deals with the analysis of small sample volume by using a planar microcoil and a micromachined cavity. This microcoil is used as a nuclear magnetic resonance (NMR) radio frequency detection coil in order to perform in vitro NMR analysis of the sample introduced into the microcavity. It is a real challenging task to develop microsystem for NMR spectrum extraction for smaller and smaller sample volume. Moreover, it is advantageous that these microsystems could be integrated in a Micro Total Analysing System (μ -TAS) as an analysing tool. In this paper, NMR theory, description, fabrication process and electrical characterization of planar microcoils receiver are described. Results obtained on NMR microspectroscopy experiments have been performed on water and ethanol, using a 1 mm diameter planar coil. This microcoil is tuned and matched at 85.13 MHz which is the Larmor frequency of proton in a 2 T magnetic field. This paper has been presented at “3e colloque interdisciplinaire en instrumentation (C2I 2004)”, École Normale Supérieure de Cachan, 29 30 janvier 2004.

  19. Low Bone Density

    MedlinePlus

    ... Density Exam/Testing › Low Bone Density Low Bone Density Low bone density is when your bone density ... people with normal bone density. Detecting Low Bone Density A bone density test will determine whether you ...

  20. A review of small animal imaging planar and pinhole spect Gamma camera imaging.

    PubMed

    Peremans, Kathelijne; Cornelissen, Bart; Van Den Bossche, Bieke; Audenaert, Kurt; Van de Wiele, Christophe

    2005-01-01

    Scintigraphy (positron emission tomography (PET) or single photon emission computed tomography (SPECT) techniques) allows qualitative and quantitative measurement of physiologic processes as well as alterations secondary to various disease states. With the use of specific radioligands, molecular pathways and pharmaco-kinetic processes can be investigated. Radioligand delivery can be (semi)quantified in the region of interest in cross-sectional and longitudinal examinations, which can be performed under the same conditions or after physiologic or pharmacologic interventions. Most preclinical pharmacokinetic studies on physiological and experimentally altered physiological processes are performed in laboratory animals using high-resolution imaging systems. Single photon emission imaging has the disadvantage of decreased spatial and temporal resolution compared with PET. The advantage of SPECT is that equipment is generally more accessible and commonly used radionuclides have a longer physical half-life allowing for investigations over a longer time interval. This review will focus on single photon emission scintigraphy. An overview of contemporary techniques to measure biodistribution and kinetics of radiopharmaceuticals in small animal in vivo is presented. Theoretical as well as practical aspects of planar gamma camera and SPECT pinhole (PH) imaging are discussed. Current research is focusing on refining PH SPECT methodology, so specific regarding technical aspects and applications of PH SPECT will be reviewed. PMID:15869162

  1. Diagnosis of osteomyelitis of the foot in diabetic patients: Value of 111In-leukocyte scintigraphy

    SciTech Connect

    Larcos, G.; Brown, M.L.; Sutton, R.T. )

    1991-09-01

    The noninvasive diagnosis of osteomyelitis of the foot in diabetic patients with currently available radiologic and radionuclide imaging techniques is often difficult. Recently, 111In-labeled leukocyte scintigraphy has been proposed as an attractive alternative. Accordingly, the authors retrospectively reviewed 51 111In-labeled leukocyte scans, 49 technetium-99m bone scans, and 49 plain radiographs obtained in 51 adults with diabetes in whom osteomyelitis of the foot was suspected. The sensitivity and specificity of these techniques were evaluated in all patients, as well as in a subgroup of 11 patients with neuroarthropathy. Results with 111In-labeled leukocyte scans were also examined in subsets of patients with soft-tissue ulcers (n = 35) and those receiving antibiotics during investigation (n = 20). Confirmation or exclusion of osteomyelitis was made surgically in 28 patients and clinically in 23. Fourteen patients had osteomyelitis. Bone scans were most sensitive (93%) but least specific (43%); plain radiographs were most specific (83%) but least sensitive (43%). 111In-labeled leukocyte scans were both sensitive (79%) and specific (78%), and remained useful in patients with neuroarthropathy, soft-tissue ulcers, and antibiotic treatment. Poor spatial resolution contributed to the false-negative and false-positive 111In-labeled leukocyte scans, suggesting that this technique should not be interpreted independent of other tests. 111In-labeled leukocyte scans are a valuable diagnostic tool for the diagnosis of pedal osteomyelitis in diabetic patients.

  2. Bone Markers

    MedlinePlus

    ... Alkaline Phosphatase; Osteocalcin; P1NP; Procollagen Type 1 N-Terminal Propeptide Formal name: Biochemical Markers of Bone Remodeling ... tests for evaluating bone turnover: C-telopeptide (C-terminal telopeptide of type 1 collagen (CTx)) – a marker ...

  3. Bone tumor

    MedlinePlus

    ... physical exam. Tests that may be done include: Alkaline phosphatase blood level Bone biopsy Bone scan Chest x- ... also affect the results of the following tests: Alkaline phosphatase isoenzyme Blood calcium level Parathyroid hormone Blood phosphorus ...

  4. Bone Infections

    MedlinePlus

    ... of the body, bones can get infected. The infections are usually bacterial, but can also be fungal. ... bloodstream. People who are at risk for bone infections include those with diabetes, poor circulation, or recent ...

  5. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    PubMed Central

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    Objectives: The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Materials and Methods: Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Results: Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Conclusion: Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management. PMID:26170564

  6. Bone cement

    PubMed Central

    Vaishya, Raju; Chauhan, Mayank; Vaish, Abhishek

    2013-01-01

    The knowledge about the bone cement is of paramount importance to all Orthopaedic surgeons. Although the bone cement had been the gold standard in the field of joint replacement surgery, its use has somewhat decreased because of the advent of press-fit implants which encourages bone in growth. The shortcomings, side effects and toxicity of the bone cement are being addressed recently. More research is needed and continues in the field of nanoparticle additives, enhanced bone–cement interface etc. PMID:26403875

  7. Bone Analyzer

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The danger of disuse osteoporosis under weightless condition in space led to extensive research into measurements of bone stiffness and mass by the Biomedical Research Division of Ames and Stanford University. Through its Technology Utilization Program, NASA funded an advanced SOBSA, a microprocessor-controlled bone probe system. SOBSA determines bone stiffness by measuring responses to an electromagnetic shaker. With this information, a physician can identify bone disease, measure deterioration and prescribe necessary therapy. The system is now undergoing further testing.

  8. Gallium-67 citrate localization in osteoclast nuclei of Paget's disease of bone

    SciTech Connect

    Mills, B.G.; Masuoka, L.S.; Graham, C.C. Jr.; Singer, F.R.; Waxman, A.D.

    1988-06-01

    Gallium-67 citrate scintigraphy has been used to indicate the extent of bone involvement in patients with Paget's disease of bone and is an excellent marker in monitoring the effects of specific therapy. Since gallium uptake is dependent on cellular function, autoradiographic techniques can be applied to cells of Paget's lesions to understand better the mechanism of (/sup 67/Ga)citrate uptake. Bone biopsies were obtained from sites of increased uptake using (/sup 67/Ga)citrate scintigraphy in two patients with Paget's disease. In both patients electron microscopic autoradiographs demonstrated a high concentration of silver grains over the nuclei of osteoclasts. The cellular mechanism is unknown but may be related to the known inhibitory effect of calcitonin on osteoclast activity. The association of (/sup 67/Ga)citrate with the nucleus of the osteoclasts is unique and different from tumor cells in which there is a high association of (/sup 67/Ga)citrate with the lysosome fraction within the cytoplasm.

  9. Fish-eye sign in scintigraphy of benign thyroid nodule

    SciTech Connect

    Vaqueiro, M.; Gharib, H.; Wahner, H.W.

    1985-11-01

    An unusual scintigraphic appearance of a benign adenomatous nodule in the thyroid is described which showed a central core of functional tissue surrounded by a rim of nonfunctioning tissue and degenerative changes. The descriptive term fish-eye sign is proposed. The characterization of tissue by scintigraphy prior to fine needle aspiration may be helpful in its interpretation.

  10. Accuracy of Hepatobiliary Scintigraphy after Liver Transplantation and Liver Resection

    PubMed Central

    Ackermann, Hanns; Bechstein, Wolf O.; Grünwald, Frank

    2016-01-01

    Background and Aims. Biliary complications are the most frequent complications after common liver surgeries. In this study, accuracy of hepatobiliary scintigraphy (HBS) and impact of hyperbilirubinemia were evaluated. Methods. Between November 2007 and February 2016, 131 patients underwent hepatobiliary scintigraphy after having liver surgery. 39 patients with 42 scans after LTX (n = 13) or hepatic resection (n = 26) were evaluated in the study; 27 were male, with mean age 60 years. The subjects underwent hepatobiliary scintigraphy with Tc-99m labeled Mebrofenin. The results were compared to ERCP as gold standard performed within one month after HBS. We calculated sensitivity, specificity, PPV, and NPV. We compared LTX patients to patients with other liver surgeries. Furthermore the influence of hyperbilirubinemia on HBS scans was evaluated. Results. HBS always provided the correct diagnosis in cases of bile leak in the liver-resected group (14/14). Overall diagnostic accuracy was 76% (19/25) in this group and 54% (7/13) in the LTX group. False negative (FN) diagnoses occurred more often among LTX patients (p = 0.011). Hyperbilirubinemia (>5 mg/dL) significantly influenced the excretion function of the liver, prolonging HBS's time-activity-curve (p = 0.001). Conclusions. Hepatobiliary scintigraphy is a reliable tool to detect biliary complications, but reduced accuracy must be considered after LTX. PMID:27563464

  11. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    SciTech Connect

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.; Aroesty, J.M.; Royal, H.D.; Parker, J.A.; Silverman, K.J.; Kolodny, G.M.; Zoll, P.M.; McKay, R.G.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort.

  12. Pointed drawings of planar graphs☆

    PubMed Central

    Aichholzer, Oswin; Rote, Günter; Schulz, André; Vogtenhuber, Birgit

    2012-01-01

    We study the problem how to draw a planar graph crossing-free such that every vertex is incident to an angle greater than π. In general a plane straight-line drawing cannot guarantee this property. We present algorithms which construct such drawings with either tangent-continuous biarcs or quadratic Bézier curves (parabolic arcs), even if the positions of the vertices are predefined by a given plane straight-line drawing of the graph. Moreover, the graph can be drawn with circular arcs if the vertices can be placed arbitrarily. The topic is related to non-crossing drawings of multigraphs and vertex labeling. PMID:23471372

  13. Terahertz super thin planar lenses

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Ye, Jiasheng; Hu, Dan; Wang, Xinke; Feng, Shengfei; Sun, Wenfeng

    2012-12-01

    Terahertz (THz) radiation is an under developing range in the electromagnetic spectrum. It has attracted a lot of attentions due to its various potential applications. However, THz systems are difficult to be integrated into a smart size due to the limitation of its long wavelength. In this presentation, we propose a new approach to design planar lenses with a thickness of several hundred nanometers in the THz range. The fabricated lenses are characterized with a focal plane imaging system and it is found that they can focus the THz light and image an object well. It is expected that this new approach can pave a way for smart THz systems integration.

  14. [Bone scanning with sodium 18F-fluoride PET and PET/CT. German guideline Version 1.0.].

    PubMed

    Hellwig, D; Krause, B-J; Schirrmeister, H; Freesmeyer, M

    2010-01-01

    In nuclear medicine, bone scanning is based on the principle of scintigraphy using bone-seeking radiopharmaceuticals which accumulate in sites of increased bone formation. From a historical point of view, (18)F-fluoride was one of the first osteotropic tracers which was replaced by (99m)Tc-labelled polyphosphonates. With the development of modern PET equipment the superior diagnostic performance of (18)F-fluoride PET for the detection and characterization of osseous lesions was proven in comparison to conventional bone scanning. Recently, its importance as a substitute of conventional skeletal scintigraphy increased in a time with limited availability of (99)Mo/(99m)Tc. To ensure health care during this period, (18)F-fluoride PET currently became part of common outpatient care. This guideline comprehends recommendations on indications, protocols, interpretation and reporting of (18)F-fluoride PET and PET/CT. PMID:20838734

  15. Liftings and stresses for planar periodic frameworks

    PubMed Central

    Borcea, Ciprian; Streinu, Ileana

    2015-01-01

    We formulate and prove a periodic analog of Maxwell’s theorem relating stressed planar frameworks and their liftings to polyhedral surfaces with spherical topology. We use our lifting theorem to prove deformation and rigidity-theoretic properties for planar periodic pseudo-triangulations, generalizing features known for their finite counterparts. These properties are then applied to questions originating in mathematical crystallography and materials science, concerning planar periodic auxetic structures and ultrarigid periodic frameworks. PMID:26973370

  16. Theory of non-planar orbits

    SciTech Connect

    Antillon, A.; Month, M.

    1985-01-01

    The basic dynamics of a planar accelerator is extended to the non-planar case. This is done using the geometrical concept of torsion and extending the Hamiltonian formalism. A generalized non-planar reference orbit is adopted which introduces torsion in appropriately chosen drift spaces. The parameters of the reference orbit are associated with uncoupled and coupled betatron parameters currently in use. 6 refs.

  17. Scan registration using planar features

    NASA Astrophysics Data System (ADS)

    Previtali, M.; Barazzetti, L.; Brumana, R.; Scaioni, M.

    2014-06-01

    Point cloud acquisition by using laser scanners provides an efficient way for 3D as-built modelling of indoor/outdoor urban environments. In the case of large structures, multiple scans may be required to cover the entire scene and registration is needed to merge them together. In general, the identification of corresponding geometric features among a series of scans can be used to compute the 3D rigid-body transformation useful for the registration of each scan into the reference system of the final point cloud. Different automatic or semi-automatic methods have been developed to this purpose. Several solutions based on artificial targets are available, which however may not be suitable in any situations. Methods based on surface matching (like ICP and LS3D) can be applied if the scans to align have a proper geometry and surface texture. In the case of urban and architectural scenes that present the prevalence of a few basic geometric shapes ("Legoland" scenes) the availability of many planar features is exploited here for registration. The presented technique does not require artificial targets to be added to the scanned scene. In addition, unlike other surface-based techniques (like ICP) the planar feature-based registration technique is not limited to work in a pairwise manner but it can handle the simultaneous alignment of multiple scans. Finally, some applications are presented and discussed to show how this technique can achieve accuracy comparable to a consolidated registration method.

  18. Planar waveguide sensor of ammonia

    NASA Astrophysics Data System (ADS)

    Rogoziński, Roman; Tyszkiewicz, Cuma; Karasiński, Paweł; Izydorczyk, Weronika

    2015-12-01

    The paper presents the concept of forming ammonia sensor based on a planar waveguide structure. It is an amplitude sensor produced on the basis of the multimode waveguide. The technological base for this kind of structure is the ion exchange method and the sol-gel method. The planar multimode waveguide of channel type is produced in glass substrate (soda-lime glass of Menzel-Glaser company) by the selective Ag+↔Na+ ion exchange. On the surface of the glass substrate a porous (~40%) silica layer is produced by the sol-gel method. This layer is sensitized to the presence of ammonia in the surrounding atmosphere by impregnation with Bromocresol Purple (BCP) dye. Therefore it constitutes a sensor layer. Spectrophotometric tests carried out showed about 50% reduction of cross-transmission changes of such sensor layer for a wave λ=593 nm caused by the presence of 25% ammonia water vapor in its ambience. The radiation source used in this type of sensor structure is a light emitting diode LED. The gradient channel waveguide is designed for frontal connection (optical glue) with a standard multimode telecommunications waveguide 62.5/125μm.

  19. Diagnosis of osteomyelitis in the presence of soft-tissue infection and radiologic evidence of osseous abnormalities: Value of leukocyte scintigraphy

    SciTech Connect

    Jacobson, A.F.; Harley, J.D.; Lipsky, B.A.; Pecoraro, R.E. )

    1991-10-01

    To evaluate the usefulness of 111In-leukocyte scintigraphy for identifying osteomyelitis in the presence of soft-tissue infection, the author prospectively studied 45 bone sites adjacent to soft-tissue infection in patients with abnormal findings on radiographs and 99mTc bone scans that were suggestive of osteomyelitis. 111In-leukocyte scans were analyzed in terms of the intensity of abnormal uptake and its location relative to bone. The diagnosis of osteomyelitis was established from results of percutaneous bone biopsy culture (n = 35), histologic examination of surgical specimens (n = 8), and clinical follow-up (n = 2). Osteomyelitis was present at 22 sites, including 16 of 18 sites with increased leukocyte uptake in bone, resulting in a sensitivity of 73%, specificity of 91%, and positive predictive value of 89% for this finding. Osteomyelitis was present at four of 17 sites with predominantly soft-tissue localization of leukocyte activity in the region of bone, none of seven sites with normal leukocyte scans, and two of three sites with diminished leukocyte uptake in bone. Although not helpful in distinguishing infectious from noninfectious bone abnormalities, 3- and especially 24-hr bone scans viewed in conjunction with leukocyte studies provided important correlation to aid in estimating the location of focal abnormal leukocyte uptake. The finding of soft-tissue infection with increased uptake of labeled leukocytes that extends to involve adjacent bone strongly suggests concurrent osteomyelitis. When the presence of abnormal leukocyte uptake in bone is uncertain, additional imaging and possibly biopsy may be required to establish or exclude the diagnosis of osteomyelitis.

  20. Diffusely discordant In-111 WBC/Tc-99m SC bone marrow uptake: A possible chemotherapeutic effect

    SciTech Connect

    Achong, D.M.; Oates, E.

    1995-07-01

    In-111 WBC scintigraphy in a women with relapsed acute lymphoid leukemia demonstrated normal uptake of white blood cells by the liver and spleen, but virtually absent bone marrow activity. Tc-99m Sc imaging confirmed normal marrow function and distribution. A bone marrow biopsy revealed mildly hypocellular, regenerating marrow without leukemic infiltration. The effects of systemic cytotoxic chemotherapy on marrow reticuloendothelial function may have been responsible for this discordant uptake. 5 refs., 2 figs.

  1. Planar Hall effect bridge magnetic field sensors

    SciTech Connect

    Henriksen, A. D.; Dalslet, B. T.; Skieller, D. H.; Lee, K. H.; Okkels, F.; Hansen, M. F.

    2010-07-05

    Until now, the planar Hall effect has been studied in samples with cross-shaped Hall geometry. We demonstrate theoretically and experimentally that the planar Hall effect can be observed for an exchange-biased ferromagnetic material in a Wheatstone bridge topology and that the sensor signal can be significantly enhanced by a geometric factor. For the samples in the present study, we demonstrate an enhancement of the sensor output by a factor of about 100 compared to cross-shaped sensors. The presented construction opens a new design and application area of the planar Hall effect, which we term planar Hall effect bridge sensors.

  2. Planarized fiber-FHD optical composite

    NASA Astrophysics Data System (ADS)

    Holmes, C.; Carpenter, L. G.; Gates, J. C.; Gawith, C. B. E.; Smith, P. G. R.

    2015-03-01

    We demonstrate the fabrication of a mechanically robust planarised fibre-FHD optical composite. Fabrication is achieved through deposition and consolidation of optical grade silica soot on to both an optical fibre and planar substrate. The consolidated silica acts in joining the fibre and planar substrate both mechanically and optically. The concept lends itself to applications where long interaction lengths (order of tens of centimetres) and optical interaction via a planar waveguide are required, such as pump schemes, precision layup of fibre optics and hybrid fibre-planar devices. This paper considers the developments in fabrication process that enable component development.

  3. Planarization of metal films for multilevel interconnects

    DOEpatents

    Tuckerman, David B.

    1987-01-01

    In the fabrication of multilevel integrated circuits, each metal layer is anarized by heating to momentarily melt the layer. The layer is melted by sweeping laser pulses of suitable width, typically about 1 microsecond duration, over the layer in small increments. The planarization of each metal layer eliminates irregular and discontinuous conditions between successive layers. The planarization method is particularly applicable to circuits having ground or power planes and allows for multilevel interconnects. Dielectric layers can also be planarized to produce a fully planar multilevel interconnect structure. The method is useful for the fabrication of VLSI circuits, particularly for wafer-scale integration.

  4. Planarization of metal films for multilevel interconnects

    DOEpatents

    Tuckerman, David B.

    1989-01-01

    In the fabrication of multilevel integrated circuits, each metal layer is anarized by heating to momentarily melt the layer. The layer is melted by sweeping laser pulses of suitable width, typically about 1 microsecond duration, over the layer in small increments. The planarization of each metal layer eliminates irregular and discontinuous conditions between successive layers. The planarization method is particularly applicable to circuits having ground or power planes and allows for multilevel interconnects. Dielectric layers can also be planarized to produce a fully planar multilevel interconnect structure. The method is useful for the fabrication of VLSI circuits, particularly for wafer-scale integration.

  5. Helical axis stellarator with noninterlocking planar coils

    DOEpatents

    Reiman, Allan; Boozer, Allen H.

    1987-01-01

    A helical axis stellarator using only noninterlocking planar, non-circular coils, generates magnetic fields having a magnetic well and large rotational transform with resultant large equilibrium beta.

  6. A review of the efficacy of bone scanning in prostate and breast cancer.

    PubMed

    O'Sullivan, J M; Cook, G J R

    2002-06-01

    Bone scintigraphy has provided valuable data in the assessment and management of neoplastic disease since being first described in the early 1960s. There have been many developments in imaging techniques and radiopharmaceuticals over the years allowing more reliable detection of metastatic spread to bone. Other imaging modalities are also evolving roles in the detection of metastatic spread including computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET). Despite this, isotope bone scans continue to have a central role in detection and surveillance of bone metastases in breast and prostate cancer. Paralleling developments in imaging there have been enormous changes in the treatment options available for cancers of the breast and prostate that have metastasised to bone. Bone specific treatments including radionuclides and bisphosphonates as well as high dose chemotherapy provide potential improvement in disease control. There is also evidence that earlier treatment of bone metastases may prolong survival. This increases the need for efficient methods of detection and monitoring of disease. In this article we discuss the efficacy of bone scintigraphy in breast and prostate cancer from the point of view of staging, systematic follow-up of asymptomatic patients, evaluation of symptomatic patients and the assessment of response to therapy. PMID:12114879

  7. An Unusual Case of Extraosseous Accumulation of Bone Scan Tracer in a Renal Calculus - Demonstration by SPECT-CT

    PubMed Central

    Joshi, Prathamesh Vijay; Lele, Vikram; Gandhi, Rozil

    2012-01-01

    Extraosseous localization of radioisotope, used in bone scan, in a variety of physiological and pathological conditions is a well-known phenomenon. The causes of extraosseous accumulation of bone-seeking radiotracers should be kept in mind when bone-imaging studies are reviewed to avoid incorrect interpretations. We report an extremely rare occurrence of extraosseous accumulation of bone scintigraphy tracer in a renal calculus, in a patient with adenocarcinoma of prostate, that was demonstrated by Single Photon Emission Computed Tomography and Computed Tomography (SPECT-CT) fusion imaging. PMID:22439128

  8. The effect of iron on the biodistribution of bone scanning agents in humans

    SciTech Connect

    Choy, D.; Murray, I.P.; Hoschl, R.

    1981-07-01

    Nine patients with chronic iron overload, resulting from either repeated transfusions or hemochromatosis, had bone scans that were characterized by a reduction of bony uptake, marked increase in renal activity, and a significant increase in soft-tissue accumulation of 99mTc-labeled bone-seeking agents. These findings were supported by semiquantitative computer analysis. The probable mechanisms of altered biodistribution and the possible role of serum ferritin are discussed. The importance of realizing the effect of excess iron on skeletal scintigraphy is further emphasized by the results of bone scanning in another patient in whom acute iron overload following infusion of iron-dextran resulted in excessive blood pool labeling.

  9. [Imaging of thromboembolism by scintigraphy with the 99m-technetium-labelled synthetic peptide P280].

    PubMed

    Lastoria, S; Vergara, E; Varrella, P; Muto, P; Acampa, W; Caracò, C; Salvatore, M

    1995-12-01

    P280, a synthetic peptide composed of 26 aminoacids, has high affinity (Kd = 100 nM) and specificity for the glycoprotein IIb/IIIa (GPIIb/IIIa) receptor expressed on activated platelets. In this study we investigated the potential usefulness of imaging deep vein thrombosis (DVT) and pulmonary embolism (PE) in humans with 99mTc-P280. In 15 patients (9 men and 6 women; mean age +/- s.d.: 49.2 +/- 14.1) with known DVT and/or PE, serial images were acquired within 24 hours of the injection of approximately 200 micrograms of P280 radiolabelled with 10-23 mCi of 99mTc. P280 was labelled with the ligand exchange method using 99mTc-glucoheptonate. Rapid blood clearance (< or = 5% ID was still circulating in 1 hour) enabled identification of thrombi as early as 60 minutes after the injection, with significant thrombi-to-background ratios (range: 2-4) in 11/15 patients (73%), in 7/9 with DVT, in 2/3 with PE and in 2/3 patients with both DVT and PE. Radiotracer uptake was clearly detectable also in late scans, which confirms that 99mTc-P280 specifically binds to the thrombi through a receptor-mediated mechanism. PE localizations were detectable 3-4 hours after peptide injection, and in 2 cases SPECT enabled the detection of thrombi missed on planar views. Conversely, the test was negative in 4 patients who had the onset of clinical symptoms and the diagnosis of DVT and/or PE more than 40 days before scintigraphy. The lack of 99mTc-P280 uptake in the latter patients suggested that the peptide does not bind to thrombi when thrombogenesis is not active. These preliminary results clearly indicate scintigraphy with 99mTc-P280 to be a suitable, noninvasive and highly specific tool to image fresh clots causing DVT and/or PE. Thus, this technique might overcome the limitations of the imaging procedures currently in use. PMID:8685469

  10. Comparison of planar images and SPECT with bayesean preprocessing for the demonstration of facial anatomy and craniomandibular disorders

    SciTech Connect

    Kircos, L.T.; Ortendahl, D.A.; Hattner, R.S.; Faulkner, D.; Taylor, R.L.

    1984-01-01

    Craniomandiublar disorders involving the facial anatomy may be difficult to demonstrate in planar images. Although bone scanning is generally more sensitive than radiography, facial bone anatomy is complex and focal areas of increased or decreased radiotracer may become obscured by overlapping structures in planar images. Thus SPECT appears ideally suited to examination of the facial skeleton. A series of patients with craniomandibular disorders of unknown origin were imaged using 20 mCi Tc-99m MDP. Planar and SPECT (Siemens 7500 ZLC Orbiter) images were obtained four hours after injection. The SPECT images were reconstructed with a filtered back-projection algorithm. In order to improve image contrast and resolution in SPECT images, the rotation views were pre-processed with a Bayesean deblurring algorithm which has previously been show to offer improved contrast and resolution in planar images. SPECT images using the pre-processed rotation views were obtained and compared to the SPECT images without pre-processing and the planar images. TMJ arthropathy involving either the glenoid fossa or the mandibular condyle, orthopedic changes involving the mandible or maxilla, localized dental pathosis, as well as changes in structures peripheral to the facial skeleton were identified. Bayesean pre-processed SPECT depicted the facial skeleton more clearly as well as providing a more obvious demonstration of the bony changes associated with craniomandibular disorders than either planar images or SPECT without pre-processing.

  11. A bioinspired planar superhydrophobic microboat

    NASA Astrophysics Data System (ADS)

    Yong, Jiale; Yang, Qing; Chen, Feng; Zhang, Dongshi; Du, Guangqing; Si, Jinhai; Yun, Feng; Hou, Xun

    2014-03-01

    In nature, a frog can easily rest on a lotus leaf even though the frog's weight is several times the weight of the lotus leaf. Inspired by the lotus leaf, we fabricated a planar superhydrophobic microboat (SMB) with a superhydrophobic upper surface on a PDMS sheet which was irradiated by a focused femtosecond laser. The SMB can not only float effortlessly over the water surface but can also hold up some heavy objects, exhibiting an excellent loading capacity. The water surface is curved near the edge of the upper surface and the SMB's upper edge is below the water level, greatly enhancing the displacement. Experimental results and theoretical analysis demonstrate that the superhydrophobicity on the edge of the upper surface is responsible for the SMB's large loading capacity. Here, we call it the ‘superhydrophobic edge effect’.

  12. Ten inch Planar Optic Display

    SciTech Connect

    Beiser, L.; Veligdan, J.

    1996-04-01

    A Planar Optic Display (POD) is being built and tested for suitability as a high brightness replacement for the cathode ray tube, (CRT). The POD display technology utilizes a laminated optical waveguide structure which allows a projection type of display to be constructed in a thin (I to 2 inch) housing. Inherent in the optical waveguide is a black cladding matrix which gives the display a black appearance leading to very high contrast. A Digital Micromirror Device, (DMD) from Texas Instruments is used to create video images in conjunction with a 100 milliwatt green solid state laser. An anamorphic optical system is used to inject light into the POD to form a stigmatic image. In addition to the design of the POD screen, we discuss: image formation, image projection, and optical design constraints.

  13. The simplicity of planar networks

    NASA Astrophysics Data System (ADS)

    Viana, Matheus P.; Strano, Emanuele; Bordin, Patricia; Barthelemy, Marc

    2013-12-01

    Shortest paths are not always simple. In planar networks, they can be very different from those with the smallest number of turns - the simplest paths. The statistical comparison of the lengths of the shortest and simplest paths provides a non trivial and non local information about the spatial organization of these graphs. We define the simplicity index as the average ratio of these lengths and the simplicity profile characterizes the simplicity at different scales. We measure these metrics on artificial (roads, highways, railways) and natural networks (leaves, slime mould, insect wings) and show that there are fundamental differences in the organization of urban and biological systems, related to their function, navigation or distribution: straight lines are organized hierarchically in biological cases, and have random lengths and locations in urban systems. In the case of time evolving networks, the simplicity is able to reveal important structural changes during their evolution.

  14. Planar microresonators for EPR experiments.

    PubMed

    Narkowicz, R; Suter, D; Stonies, R

    2005-08-01

    EPR resonators on the basis of standing-wave cavities are optimised for large samples. For small samples it is possible to design different resonators that have much better power handling properties and higher sensitivity. Other parameters being equal, the sensitivity of the resonator can be increased by minimising its size and thus increasing the filling factor. Like in NMR, it is possible to use lumped elements; coils can confine the microwave field to volumes that are much smaller than the wavelength. We discuss the design and evaluation of EPR resonators on the basis of planar microcoils. Our test resonators, which operate at a frequency of 14 GHz, have excellent microwave efficiency factors, achieving 24 ns pi/2 EPR pulses with an input power of 17 mW. The sensitivity tests with DPPH samples resulted in the sensitivity value 2.3 x 10(9) spins.G(-1) Hz(-1/2) at 300 K. PMID:15939642

  15. Planar microresonators for EPR experiments

    NASA Astrophysics Data System (ADS)

    Narkowicz, R.; Suter, D.; Stonies, R.

    2005-08-01

    EPR resonators on the basis of standing-wave cavities are optimised for large samples. For small samples it is possible to design different resonators that have much better power handling properties and higher sensitivity. Other parameters being equal, the sensitivity of the resonator can be increased by minimising its size and thus increasing the filling factor. Like in NMR, it is possible to use lumped elements; coils can confine the microwave field to volumes that are much smaller than the wavelength. We discuss the design and evaluation of EPR resonators on the basis of planar microcoils. Our test resonators, which operate at a frequency of 14 GHz, have excellent microwave efficiency factors, achieving 24 ns π/2 EPR pulses with an input power of 17 mW. The sensitivity tests with DPPH samples resulted in the sensitivity value 2.3 × 10 9 spins · G -1Hz -1/2 at 300 K.

  16. An Incidental Detection of Popliteal Vein Aneurysm during Labeled Leukocyte Scintigraphy

    PubMed Central

    Hassan, H. Abu.; Nazri, M.; Azman, R. R.

    2012-01-01

    Technetium (99mTc) exametazime (hexamethylpropyleneamine oxime, HMPAO) labeled leukocyte scintigraphy is mainly used to exclude occult infection in our institution. On review of previously published article, no case of popliteal venous aneurysm was ever diagnosed and detected on labeled leukocyte scintigraphy. We present a rare case of popliteal venous aneurysm which was detected on labeled leukocyte scintigraphy and was further confirmed with single-photon emission computed tomography and computed tomography fusion. PMID:23372443

  17. Improved double planar probe data analysis technique

    SciTech Connect

    Ghim, Young-chul; Hershkowitz, Noah

    2009-03-15

    Plasma electron number density and ion number density in a dc multidipole weakly collisional Ar plasma are measured with a single planar Langmuir probe and a double planar probe, respectively. A factor of two discrepancy between the two density measurements is resolved by applying Sheridan's empirical formula [T. E. Sheridan, Phys. Plasmas 7, 3084 (2000)] for sheath expansion to the double probe data.

  18. Positron Emission Mammotomography with Dual Planar Detectors

    SciTech Connect

    Mark Smith; Raymond Raylman; Stanislaw Majewski

    2003-06-29

    Positron emission mammography (PEM) is usually performed with two stationary planar detectors above and below a compressed breast. There is image blurring normal to the detectors due to the limited angular range of the lines of response. Positron emission mammotomography (PEM-T) with dual planar detectors rotating about the breast can obtain complete angular sampling and has the potential to improve activity estimation.

  19. Disturbances of bone growth and development

    SciTech Connect

    Ledesma-Medina, J.; Newman, B.; Oh, K.S.

    1988-03-01

    ''What is growth anyway. Can one talk about positive growth in childhood, neutral growth in maturity, and negative growth in old age. Our goal is to help promote normal positive growth in infants and children. To achieve this, we must be cognizant of the morphologic changes of both normal and abnormal bone formation as they are reflected in the radiographic image of the skeleton. The knowledge of the various causes and the pathophysiologic mechanisms of the disturbances of bone growth and development allows us to recognize the early radiographic manifestations. Endocrine and metabolic disorders affect the whole skeleton, but the early changes are best seen in the distal ends of the femurs, where growth rate is most rapid. In skeletal infections and in some vascular injuries two-or three-phase bone scintigraphy supercedes radiography early in the course of the disease. MRI has proved to be very helpful in the early detection of avascular bone necrosis, osteomyelitis, and tumor. Some benign bone tumors and many bone dysplasias have distinct and diagnostic radiographic findings that may preclude further studies. In constitutional diseases of bone, including chromosomal aberrations, skeletal surveys of the patient and all family members together with biochemical and cytogenetic studies are essential for both diagnosis and genetic counseling. Our role is to perform the least invasive and most informative diagnostic imaging modalities that corroborate the biochemical and histologic findings to establish the definitive diagnosis. Unrecognized, misdiagnosed, or improperly treated disturbance of bone growth can result in permanent deformity usually associated with disability. 116 references.

  20. [Bone diseases].

    PubMed

    Uebelhart, Brigitte; Rizzoli, René

    2016-01-13

    Calcium intake shows a small impact on bone mineral density and fracture risk. Denosumab is a more potent inhibitor of bone resorption than zoledronate. Abaloparatide, PTHrP analog, increases bone mineral density and decreases fracture incidence. Teriparatide could be delivered via a transdermic device. Romosozumab and odanacatib improve calculated bone strength. Sequential or combined treatments with denosumab and teriparatide could be of interest, but not denosumab followed by teriparatide. Fibrous dysplasia, Paget disease and hypophosphatasia are updated, as well as atypical femoral fracture and osteonecrosis of the jaw. PMID:26946704

  1. Interest of somatostatin receptors scintigraphy for imaging differentiated thyroid carcinoma tumor sites

    SciTech Connect

    Giammarile, F.; Lumbroso, J.; Schlumberger, M.

    1995-05-01

    Despite the fact that differentiated thyroid carcinoma (DTC) is not classified as a neuroendocrine tumor, there is an increasing interest for the use of somatostatin receptors scintigraphy (SRS) in this disease. We evaluated SRS in DTC patients having no or a poor radioiodine uptake at the level of their tumor sites. Nine patients (pts) (7 men, 2 women; aged from 52 to 65 years) were previously treated (surgery of the primary: 9/9pts; followed by cervical radiotherapy: 4/9pts; radioiodine therapy: 8/9pts; surgery or radiotherapy to bone metastases: 2/9 pts) for DTC (papillary form: 6 pts; follicular; 1 pts; insular: 2 pts). They were explored by conventional imaging modalities (CIM) including Tc-99m MDP bone scans. High activity radioiodine scans were obtained 5 days after I-131 therapy. SRS was carried out during thyroxine therapy using Indium-111 pentetreotide (120 MBq) with imaging at 4 and 24 hours after injection (whole body scans and, when necessary, SPECT). Thyroglobulin blood level ranged from 120 to 60,000ng/ml. SRS was positive at the level of all tumor sites in 8/9 pts; radioiodine scans were negative in 4 pts (1pt with an insular DTC, 3 pt with a papillary DTC), slightly positive in 2 pts (papillary DTC), positive only on part of tumor sites in 1 pts (insular DTC), positive in 1 pt (follicular DTC) and not done in 1 pt. SRS demonstrated 3 new tumor sites (1 to bone, 1 to lung and 1 to mediastinal lymph nodes) in 2 pts; in an other pt, SRS clarified out a doubtful Tc-99m bone scan result and led to definitive confirmation of bone metastases. We had only 1 false negative result in 1 pt having pulmonary metastases (slightly positive radioiodine scan) which had been stable in size on CT for 6 years. These results indicate that, when radioiodine scans are ineffective, SRS is a powerful modality for imaging DTC tumor sites.

  2. [Diagnostic benefits of adrenocortical scintigraphy in hepatic adrenal rest tumor].

    PubMed

    Ishida, Kosuke; Horii, Rika; Yamashita, Tatsuya; Arai, Kuniaki; Yamashita, Taro; Kagaya, Takashi; Sakai, Yoshio; Mizukoshi, Eishiro; Honda, Masao; Kaneko, Shuichi

    2014-10-01

    An 81-year-old female was referred to our hospital for the examination of an S7 liver tumor. The tumor was suspected to be a hepatic adrenal rest tumor (HART) based on ultrasonography, dynamic CT, Gd-EOB-DTPA-enhanced MRI, and CT during abdominal angiography. After various hormonal tests, the tumor was confirmed as hormonally non-functional. The diagnosis of HART was confirmed based on (131)I-adosterol accumulation in the tumor by adrenocortical scintigraphy. The resected tumor was histologically compatible with HART, and it may have been able to produce cortisol based on the immunohistochemical findings of various adrenocortical hormone metabolic enzymes. Adrenocortical scintigraphy may thus be useful in diagnosing HART. PMID:25283230

  3. Role of scintigraphy in focally abnormal sonograms of fatty livers

    SciTech Connect

    Lisbona, R.; Mishkin, S.; Derbekyan, V.; Novales-Diaz, J.A.; Roy, A.; Sanders, L.

    1988-06-01

    Fatty infiltration of the liver may cause a range of focal abnormalities on hepatic sonography which may simulate hepatic nodular lesions. Discrete deposits of fat or islands of normal tissue which are uninvolved by fatty infiltration may stand out as potential space-occupying lesions on the sonograms. Twelve patients with such focally abnormal ultrasound images were referred for liver scintigraphy with /sup 133/Xe and /sup 99m/Tc colloidal SPECT studies to clarify the issue. These examinations helped identify, in nine of 12 patients, the innocent nature of the sonographic abnormalities which were simply related to the fat deposition process. Further, (/sup 99m/Tc)RBC scans defined the additional pathologic process in three patients in whom actual space-occupying lesions were indeed present in the liver. Scintigraphy has an important role to play in the understanding of focal hepatic ultrasound abnormalities particularly in unsuspected hepatic steatosis.

  4. Indium-111 leukocyte scintigraphy in Wegener's granulomatosis involving the spleen

    SciTech Connect

    Morayati, S.J.; Fink-Bennett, D.

    1986-12-01

    Indium-111-labeled leukocyte scintigraphy was performed on a 44-yr-old man to exclude an occult abscess. Four- and twenty-four-hour images of the abdomen revealed splenic photopenia except for a rim of activity medially. A subsequent computed tomography (CT) study demonstrated necrosis or hemorrhage of the spleen except for a medial rim. Exploratory laparotomy demonstrated necrotizing vasculitis with granuloma formation consistent with Wegener's granulomatosis and a rim of viable splenic tissue corresponding to the radionuclide and CT studies.

  5. Thallium-201 myocardial scintigraphy in acute myocardial infarction and ischemia

    SciTech Connect

    Wackers, F.J.

    1982-04-01

    Thallium-201 scintigraphy provides a sensitive and reliable method of detecting acute myocardial infarction and ischemia when imaging is performed with understanding of the temporal characteristics and accuracy of the technique. The results of scintigraphy are related to the time interval between onset of symptoms and time of imaging. During the first 6 hr after chest pain almost all patients with acute myocardial infarction and approximately 50% of the patients with unstable angina will demonstrate /sup 201/TI pefusion defects. Delayed imaging at 2-4 hr will permit distinction between ischemia and infarction. In patients with acute myocardial infarction, the size of the perfusion defect accurately reflects the extent of the infarcted and/or jeopardized myocardium, which may be used for prognostic stratification. In view of the characteristics of /sup 201/TI scintigraphy, the most practical application of this technique is in patients in whom myocardial infarction has to be ruled out, and for early recognition of patients at high risk for complications.

  6. Is 99mTc-MIBI scintigraphy a predictor of response to pre-operative neoadjuvant chemotherapy in Osteosarcoma?

    PubMed Central

    Gharehdaghi, Mohammad; Dabbagh Kakhki, Vahid Reza; Khooei, Alireza; Novferesti, Gholamhosein; Hootkani, Alireza; Farzadnia, Mahdi; Sadeghi, Ramin

    2013-01-01

    Objectives: Multidrug resistance (MDR), which may be due to the over expression of P-glycoprotein (Pgp) and/or MRP, is a major problem in neoadjuvant chemotherapy of osteosarcoma. The aim of this study was to investigate the role of Tc-99m MIBI scan for predicting the response to pre-operative chemotherapy. Methods: Twenty-five patients (12 males and 13 females, aged between 8 and 52y) with osteosarcoma were studied. Before the chemotherapy, planar 99mTc-MIBI anterior and posterior images were obtained 10-min [tumor-to-background ratio: (T1/B1)10min] and 3-hr after tracer injection. After completion of chemotherapy, again 99mTc-MIBI scan was performed at 10-min after tracer injection. In addition to calculation of decay corrected tumor to background (T/B) ratios, using the 10-min and 3-hr images of the pre-chemotherapy scintigraphy, percent wash-out rate (WR%) of 99mTc-MIBI was calculated. Using the 10-min images of the pre- and post-chemotherapy scans, the percent reduction in uptake at the tumor site after treatment (Red%) was also calculated. Then after surgical resection, tumor response was assessed by percentage of necrosis. Results: All patients showed significant 99mTc-MIBI uptake in early images. Only 9 patients showed good response to chemotherapy (necrosis≥90%) while 16 patients were considered as non-responder (necrosis<90%). There was no statistical significant difference between non-responders and responders in (T1/B1)10min.There was a significant negative correlation between WR% and percentage of necrosis (P=0.001). On the other hand, there was a significant correlation between Red% and percentage of necrosis (P<0.001).There was also statistical significant difference in WR% and Red% between non-responders and responders (both P< 0.001). Conclusion: Washout rate of 99mTc-MIBI in pre-chemotherapy scintigraphy as well as Red% using pre- and post-chemotherapy MIBI scintigraphy are useful methods for predicting response to neoadjuvant chemotherapy.

  7. Talking Bones.

    ERIC Educational Resources Information Center

    Johnson, Jaclyn; Kassing, Sharon

    2002-01-01

    Describes cooperation with the Saint Louis Zoo to provide opportunities for elementary school students to learn about bones, how animals move, what they eat, and how much they grow. Uses biofacts which include bones, skulls, and other parts to make the laboratory a hands-on experience for students. (YDS)

  8. Bone Infections

    MedlinePlus

    ... include those with diabetes, poor circulation, or recent injury to the bone. You may also be at risk if you are having hemodialysis. Symptoms of bone infections include Pain in the infected area Chills and fever Swelling, warmth, and redness A blood ...

  9. The use of indium-111 oxine platelet scintigraphy and survival studies in pediatric patients with thrombocytopenia

    SciTech Connect

    Castle, V.P.; Shulkin, B.L.; Coates, G.; Andrew, M. )

    1989-11-01

    We have utilized {sup 111}In-labeled heterologous platelets to investigate the mechanism of thrombocytopenia in ten children. From the scintigraphic findings, platelet survival times, and clinical information, thrombocytopenia was ascribed to decreased production or to increased destruction. Two patients were found to have bone marrow production defects. Two patients with hemangiomas were studied. In one, the hemangioma was shown not to be the cause of thrombocytopenia. In the second, the hemangioma was proven the source of platelet destruction, but was much more extensive than clinically evident. In both, surgical manipulation of the hemangioma was avoided. Six additional patients had thrombocytopenia due to accelerated destruction. In four, the spleen was shown responsible. In two, however, the spleen was shown not to be responsible for the low platelet counts, and splenectomy was avoided. Thus, {sup 111}In-platelet scintigraphy and survival studies are valuable in the classification and management of childhood thrombocytopenia. We believe that this study should be performed, when possible, in any child with thrombocytopenia where the mechanism is unclear or the therapeutic intervention involves splenectomy or resection of a hemangioma.

  10. Planar doped barrier subharmonic mixers

    NASA Technical Reports Server (NTRS)

    Lee, T. H.; East, J. R.; Haddad, G. I.

    1992-01-01

    The Planar Doped Barrier (PDB) diode is a device consisting of a p(+) doping spike between two intrinsic layers and n(+) ohmic contacts. This device has the advantages of controllable barrier height, diode capacitance and forward to reverse current ratio. A symmetrically designed PDB has an anti-symmetric current vs. voltage characteristic and is ideal for use as millimeter wave subharmonic mixers. We have fabricated such devices with barrier heights of 0.3, 0.5 and 0.7 volts from GaAs and InGaAs using a multijunction honeycomb structure with junction diameters between one and ten microns. Initial RF measurements are encouraging. The 0.7 volt barrier height 4 micron GaAs devices were tested as subharmonic mixers at 202 GHz with an IF frequency of 1 GHz and had 18 dB of conversion loss. The estimated mismatch loss was 7 dB and was due to higher diode capacitance. The LO frequency was 100.5 GHz and the pump power was 8 mW.

  11. Piezo Voltage Controlled Planar Hall Effect Devices

    NASA Astrophysics Data System (ADS)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K. W.; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  12. Paget's Disease of Bone

    MedlinePlus

    ... page please turn Javascript on. Paget's Disease of Bone What is Paget's Disease of Bone? Click for more information Enlarged and Misshapen Bones Paget's disease of bone causes affected bones to ...

  13. Metastatic Bone Disease

    MedlinePlus

    ... Bone Disease cont. Page ( 4 ) MBD vs. Primary Bone Cancer The diagnosis of metastatic bone disease should not ... from an unknown primary carcinoma or a primary bone cancer (sarcoma). For example, if an area of bone ...

  14. Bone x-ray

    MedlinePlus

    ... or broken bone Bone tumors Degenerative bone conditions Osteomyelitis (inflammation of the bone caused by an infection) ... Multiple myeloma Osgood-Schlatter disease Osteogenesis imperfecta Osteomalacia Osteomyelitis Paget disease of the bone Rickets X-ray ...

  15. Indium-111 leukocyte scintigraphic detection of subclinical osteomyelitis complicating delayed and nonunion long bone fractures: a prospective study

    SciTech Connect

    Esterhai, J.L. Jr.; Goll, S.R.; McCarthy, K.E.; Velchik, M.; Alavi, A.; Brighton, C.T.; Heppenstall, R.B.

    1987-01-01

    Twenty patients were studied prospectively with indium-labeled leukocyte imaging to evaluate its effectiveness in differentiating noninfected delayed or nonunion from osteomyelitis complicating these entities. All patients underwent an open surgical procedure within 24 h of the scan. Bone specimens from the nonunion site were obtained for microbiological and histological analysis to confirm the presence or absence of osteomyelitis. In these twenty patients, the sensitivity of the indium scintigraphy was 100%, the specificity 100%, and the overall accuracy 100%. Indium-labeled leukocyte scintigraphy is significantly more accurate than /sup 99m/technetium and /sup 67/gallium imaging had been, when studied earlier, in detecting subclinical osteomyelitis complicating nonunion. Indium-labeled leukocyte scintigraphy should supplant sequential technetium and gallium studies in this patient population when the surgeon must determine whether subclinical osteomyelitis is complicating fracture management of delayed and nonunions.

  16. Bilateral generalised synovial chondromatosis of the knee: Bone scintigraphic demonstration with radiologic correlation

    PubMed Central

    Elri, Tarik; Cabuk, Mehmet; Salihoglu, Yavuz Sami; Erdemir, Rabiye Uslu; Serifoglu, Ismail

    2016-01-01

    A 67-year-old woman with a history of bilateral progressive knee pain and swelling was referred for 99mTc-methyl diphosphonate bone scintigraphy. Flow and blood pool images showed bilateral heterogeneous increased uptake and delayed phase revealed mass-looking lobulated heterogeneous increased activity in both of knees extending distal part of the femoral shaft, but no other pathologic uptake was found in rest of the body. A diagnosis of synovial chondromatosis was made when correlated with X-ray and computed tomography.(CT) images. This is a rare presentation of generalized synovial chondromatosis involving both knees which demonstrated on bone scintigraphy with X-ray and CT correlation. PMID:27385904

  17. Bilateral generalised synovial chondromatosis of the knee: Bone scintigraphic demonstration with radiologic correlation.

    PubMed

    Elri, Tarik; Cabuk, Mehmet; Salihoglu, Yavuz Sami; Erdemir, Rabiye Uslu; Serifoglu, Ismail

    2016-01-01

    A 67-year-old woman with a history of bilateral progressive knee pain and swelling was referred for (99m)Tc-methyl diphosphonate bone scintigraphy. Flow and blood pool images showed bilateral heterogeneous increased uptake and delayed phase revealed mass-looking lobulated heterogeneous increased activity in both of knees extending distal part of the femoral shaft, but no other pathologic uptake was found in rest of the body. A diagnosis of synovial chondromatosis was made when correlated with X-ray and computed tomography.(CT) images. This is a rare presentation of generalized synovial chondromatosis involving both knees which demonstrated on bone scintigraphy with X-ray and CT correlation. PMID:27385904

  18. The functional hepatic volume assessed by 99mTc-GSA hepatic scintigraphy.

    PubMed

    Wu, J; Ishikawa, N; Takeda, T; Tanaka, Y; Pan, X Q; Sato, M; Todoroki, T; Hatakeyama, R; Itai, Y

    1995-11-01

    The accuracy of measurement of the functional hepatic volume by single photon emission computed tomography (SPECT) with 99mTc-galactosyl serum albumin (99mTc-GAS) was evaluated. 99mTc-GSA planar scintigraphic images were obtained dynamically and the hepatic SPECT imaging was then performed in 25 patients with hepatobiliary tumors. The patients were divided into 4 groups with normal hepatic function, and mild, moderate and severe hepatic dysfunction. The functional hepatic volume determined by SPECT was compared with the morphological hepatic volume determined by compute tomography. The ratio of the hepatic volumes obtained by the two methods was calculated. The mean hepatic volume ratio was 96.6 +/- 2.3% in the normal hepatic function group and 95.9 +/- 2.2% in the mild dysfunction group (n.s.). In both the moderate and severe hepatic dysfunction groups, the hepatic volume ratio was smaller than that in the normal group (87.9 +/- 5.2%, p < 0.0001, and 71.9 +/- 7.6%, p < 0.0001, respectively). There was a linear correlation between the hepatic volume ration and various indices of reserve hepatic function, such as LHL15 (r = 0.83, p < 0.0001), HH15(r = 0.74, p < 0.0001), and ICG15 (r = 0.75, p < 0.0005). These results indicate that the hepatic volume ratio is proportional to the severity of hepatic dysfunction, and suggest that the functional hepatic volume measured with 99mTc-GSA faithfully reflects the functioning hepatocyte mass. 99mTc-GSA scintigraphy and hepatic SPECT therefore provide information regarding global and regional reserve hepatic function. PMID:8770291

  19. Gallbladder Activity on 99mTc-Labeled Red Cell Scintigraphy Confirmed by SPECT/CT Imaging.

    PubMed

    Wang, Ling; Jing, Hongli; Chen, Libo; Wang, Zhenghua; Li, Fang

    2016-09-01

    Tc-labeled red cell (Tc-RBC) scintigraphy is commonly used to detect gastrointestinal bleeding. Gallbladder visualization on Tc-RBC scintigraphy is not common. We present a case of gallbladder visualization on Tc-RBC scintigraphy confirmed by SPECT/CT imaging in a patient with chronic renal failure and anemia. PMID:27405034

  20. Imaging of the symptomatic type II accessory navicular bone.

    PubMed

    Mosel, Leigh D; Kat, Evelyn; Voyvodic, Frank

    2004-06-01

    Accessory ossicles of the foot are commonly mistaken for fractures. The accessory navicular is one of the most common accessory ossicles of the foot. There is a higher incidence in women and the finding might be bilateral in 50-90%. This entity is usually asymptomatic, although populations with medial foot pain have a higher prevalence. Three types of accessory navicular bone have been described. The type II accessory navicular is the most commonly symptomatic variant with localized chronic or acute on chronic medial foot pain and tenderness with associated inflammation of overlying soft tissues. Plain radiographic identification of the accessory navicular is insufficient to attribute symptomatology. Ultrasound allows for comparison with the asymptomatic side and localization of pain. Bone scintigraphy has a high sensitivity but positive findings lack specificity. Magnetic resonance imaging is of high diagnostic value for demonstrating both bone marrow and soft tissue oedema. PMID:15230772

  1. Failure of Gallium-67 scintigraphy to identify reliably noninfectious interstitial nephritis: concise communication

    SciTech Connect

    Graham, G.D.; Lundy, M.M.; Moreno, A.J.

    1983-07-01

    Gallium-67 scintigraphy has been reported to be useful in the diagnosis of noninfectious interstitial nephritis. We studied 12 patients with Ga-67 citrate that were diagnosed as having noninfectious interstitial nephritis on renal biopsy. Only seven of the twelve patients with interstitial nephritis on biopsy were scan-positive. Gallium-67 scintigraphy may not reliably identify noninfectious interstitial nephritis.

  2. Nuclear medicine imaging of bone infections.

    PubMed

    Love, C; Palestro, C J

    2016-07-01

    Osteomyelitis is a broad group of infectious diseases that involve the bone and/or bone marrow. It can arise haematogenously, via extension from a contiguous infection, or by direct inoculation during surgery or trauma. The diagnosis is not always obvious and imaging tests are frequently performed as part of the diagnostic work-up. Commonly performed radionuclide tests include technetium-99m ((99m)Tc)-diphosphonate bone scintigraphy (bone), and gallium-67 ((67)Ga) and in vitro labelled leukocyte (white blood cell; WBC) imaging. Although they are useful, each of these tests has limitations. Bone scintigraphy is sensitive but not specific, especially when underlying osseous abnormalities are present. (67)Ga accumulates in tumour, trauma, and in aseptic inflammation; furthermore, there is typically an interval of 1-3 days between radiopharmaceutical injection of and imaging. Currently, this agent is used primarily for spinal infections. Except for the spine, WBC imaging is the nuclear medicine test of choice for diagnosing complicating osteomyelitis. The in vitro leukocyte labelling process requires skilled personnel, is laborious, and is not always available. Complementary marrow imaging is usually required to maximise accuracy. Not surprisingly, alternative radiopharmaceuticals are continuously being investigated. Radiolabelled anti-granulocyte antibodies and antibody fragments, investigated as in vivo leukocyte labelling agents, have their own limitations and are not widely available. (111)In-biotin is useful for diagnosing spinal infections. Radiolabelled synthetic fragments of ubiquicidin, a naturally occurring human antimicrobial peptide that targets bacteria, have shown promise as infection specific radiopharmaceuticals. 2-[(18)F]-fluoro-2-deoxy-d-glucose (FDG) positron-emission tomography (PET) with or without computed tomography (CT) is very useful in musculoskeletal infection. Sensitivities of more than 95% and specificities ranging from 75-99% have been

  3. On linear area embedding of planar graphs

    NASA Astrophysics Data System (ADS)

    Dolev, D.; Trickey, H.

    1981-09-01

    Planar embedding with minimal area of graphs on an integer grid is one of the major issues in VLSI. Valiant (V) gave an algorithm to construct a planar embedding for trees in linear area; he also proved that there are planar graphs that require quadratic area. An algorithm to embed outerplanar graphs in linear area is given. This algorithm is extended to work for every planar graph that has the following property: for every vertex there exists a path of length less than K to the exterior face, where K is a constant. Finally, finding a minimal embedding area is shown to be NP-complete for forests, and hence more general types of graphs.

  4. Non-planar microfabricated gas chromatography column

    DOEpatents

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  5. Novel Planar and Integrated Microwave Antennas

    NASA Technical Reports Server (NTRS)

    Saed, Mohammad A.

    2000-01-01

    This project dealt with design, analysis, and testing of new types of planar and integrated antennas operating in the microwave frequency range. The following was accomplished during this project period:

  6. False negative bone scans in pediatric sepsis of the axial skeleton

    SciTech Connect

    Perloff, K.G.; Glancy, G.L.; Perloff, J.J.

    1988-12-01

    The early diagnosis of disk space infections and sacroiliitis in children can be difficult because of protean presenting symptoms, nonspecific laboratory studies, and normal plain films. Technetium phosphate scintigraphy has been reported as a diagnostic method with an accuracy of up to 100% in some series. In this case report we present two patients with negative technetium bone scans in the face of active infection, illustrating the need to pursue the diagnosis using other modalities.

  7. Disseminated metastatic disease of osteosarcoma of the femur in the abdomen: unusual metastatic pattern on Tc-99m MDP bone scan.

    PubMed

    Karacalioglu, Ozgur; Ilgan, Seyfettin; Kuzhan, Okan; Emer, Ozdes; Ozguven, Mehmet

    2006-07-01

    A 25-year-old patient with osteosarcoma of the right distal femur underwent a bone scintigraphy with Tc-99m methylene diphosphonate (MDP). Whole-body bone scan revealed extensive metastatic disease in the abdominal region. Abdominal computerized tomography confirmed the presence of ascites and calcified masses on the greater omentum and peritoneal surfaces. Here we describe a case of unusual metastatic pattern of an osteosarcoma showing extensive intraabdominal metastases without prominent lung involvement after intensive chemotherapy. PMID:16922473

  8. Improved double planar probe data analysis technique.

    PubMed

    Ghim Kim, Young-Chul; Hershkowitz, Noah

    2009-03-01

    Plasma electron number density and ion number density in a dc multidipole weakly collisional Ar plasma are measured with a single planar Langmuir probe and a double planar probe, respectively. A factor of two discrepancy between the two density measurements is resolved by applying Sheridan's empirical formula [T. E. Sheridan, Phys. Plasmas 7, 3084 (2000)] for sheath expansion to the double probe data. PMID:19334917

  9. The Planar Gauge in a New Formalism

    NASA Astrophysics Data System (ADS)

    Leibbrandt, George; Nyeo, Su-Long

    The main feature of the planar gauge, apart from the decoupling of ghosts, is the nontransversality of the Yang-Mills self-energy with the resulting appearance of a pincer diagram in the Ward identity. We employ the general prescription for axial-type gauges, recently developed by one of the authors, to check this Ward identity and derive BRS-invariant counterterms in the planar gauge.

  10. The planar gauge in a new formalism

    SciTech Connect

    Leibbrandt, G.; Nyeo, S.L.

    1988-09-01

    The main feature of the planar gauge, apart from the decoupling of ghosts, is the nontransversatility of the Yang-Mills self-energy with the resulting appearance of a pincer diagram in the Ward identity. The authors employ the general prescription for axial-type gauges, recently developed by one of the authors, to check this Ward identity and derive BRS-invariant counterterms in the planar gauge.

  11. Magnetization of planar four-fermion systems

    SciTech Connect

    Caldas, Heron; Ramos, Rudnei O.

    2009-09-15

    We consider a planar system of fermions, at finite temperature and density under a static magnetic field parallel to the two-dimensional plane. This magnetic field generates a Zeeman effect and then a spin polarization of the system. The critical properties are studied from the Landau's free energy. The possible observable consequences of the magnetization of planar systems such as polymer films and graphene are discussed.

  12. Intrahepatic versus extrahepatic cholestasis. Discrimination with biliary scintigraphy combined with ultrasound

    SciTech Connect

    Lieberman, D.A.; Krishnamurthy, G.T.

    1986-03-01

    Biliary scintigraphy and ultrasound imaging were performed in 52 patients with suspected biliary tract pathology. Results were correlated with the findings of direct cholangiography. Several new innovations in scintigraphic technique were used. The combination of ultrasound imaging and scintigraphy correctly identified biliary tract obstruction in 17 of 19 patients, 12 of whom had dilated bile ducts on ultrasonography. Intrahepatic cholestasis was correctly diagnosed in 11 of 13 patients. Accurate discrimination between intrahepatic and extrahepatic cholestasis was achieved in 28 of 32 patients (88%) with the combined studies. Scintigraphy also provided a correct diagnosis of acute cholecystitis in all 9 patients with surgically confirmed disease. Eleven additional patients with gallbladder or pancreatic disease had normal bile ducts at scintigraphy, which was confirmed with cholangiography. When combined with ultrasound imaging, modern biliary scintigraphy can (a) provide excellent discrimination between intrahepatic and extrahepatic cholestasis and (b) help determine the need for subsequent invasive diagnostic studies in selected patients.

  13. Thallium-201 scintigraphy of the suppressed thyroid: an alternative for iodine-123 scanning after TSH stimulation

    SciTech Connect

    Corstens, F.; Huysmans, D.; Kloppenborg, P.

    1988-08-01

    Thallium-201 scintigraphy of the thyroid gland suppressed by autonomous nodule was compared with /sup 123/I scintigraphy after TSH stimulation. In all patients, similar images were obtained by both methods. In 20 patients, the contralateral lobe was visualized on both scans and in 14 of these, the upper pole of the ipsilateral lobe was also visualized. In one patient, neither /sup 123/I scanning after TSH nor /sup 201/TI scintigraphy showed any extranodular tissue. This study suggests that /sup 201/TI scintigraphy is a reliable alternative for scanning after TSH. It is a relatively simple method, not inducing any TSH-related allergic reactions. Iodine uptake in extranodular tissue is not stimulated and therefore, /sup 201/TI scintigraphy and radioiodine therapy can be combined on one day, without increasing the risk of radiation damage to the normal thyroid tissue with a resultant post-treatment hypothyroidism.

  14. Optimized planar micro-optic concentrator design

    NASA Astrophysics Data System (ADS)

    Pan, Jui-Wen; Su, Yu-Chung; Lee, Sheng-Yi

    2016-06-01

    The structural parameters of a planar micro-optic concentrator are optimized. First, the direct-loss is minimized by altering the relationship between the f-number of the lenslet, the angle of the micro-structure and the ray paths in the planar micro-optic concentrator. Second, the size of the micro-structure is made equal to the mini-blur size of the lenslet in order to reduce the non-direct loss. Last, the f-number and the entrance pupil diameter of the lenslet are determined by the relationships among the f-number, the entrance pupil diameter, the optical efficiency, the acceptance angle and the thickness of the planar micro-optic concentrator from the optical simulation results. For an optimized planar micro-optic concentrator with a 300× concentration, the f-number of the lenslet, the EPD of the lenslet, the angle of the micro-structure and the thickness of the planar micro-optic concentrator are 2.6, 1.49 mm, 120 degrees and 5.97 mm, respectively. For micro-structures 28.95 μm, 51.24 μm and 88.29 μm in size, the half acceptance angles of the planar micro-optic concentrator are 0.115 degrees, 0.275 degrees and 0.55 degrees, respectively, and the optical efficiencies are 81.23%, 71.92% and 50.02%, respectively.

  15. Electron-optical systems for planar gyrotrons

    NASA Astrophysics Data System (ADS)

    Manuilov, V. N.; Zaslavsky, V. Yu.; Ginzburg, N. S.; Glyavin, M. Yu.; Kuftin, A. N.; Zotova, I. V.

    2014-02-01

    The methodology of designing an electron-optical system (EOS) that forms sheet helical electron beams (HEBs) for high-power gyrotrons is developed. As an example, we consider the EOS for a 140-GHz gyrotron operated at the first harmonic of the cyclotron frequency with an accelerating voltage of 50 kV, a beam current of 30 A, and a magnetic field compression of 36. A planar geometry of the magnetron-injection gun (MIG) is suggested. The adiabatic theory of MIGs modified for the planar geometry of EOS is used for preliminary estimations of MIG parameters. Numerical simulation of the HEB properties based on the CST STUDIO SUITE 3D code is performed to find the optimal configuration of a planar MIG. The accuracy of the calculated data is discussed. The main factors that affect the HEB quality are considered. It is shown that a sheet HEB with a pitch-factor of 1.3 and velocity spread not exceeding 25%-30% can be formed; this is quite acceptable for high-efficiency operation of modern gyrotrons. Calculation of the beam-wave interaction with the obtained HEB parameters proved that a high output power with a sufficiently good efficiency of about 20% can be reached. Simulations show the feasibility of the experimental implementation of a novel planar EOS and its use in short-wave planar gyrotrons. The developed technique can be used for the study and optimization of planar gyrotrons of different frequency bands and power levels.

  16. Nuclear magnetic resonance proton imaging of bone pathology

    SciTech Connect

    Atlan, H.; Sigal, R.; Hadar, H.; Chisin, R.; Cohen, I.; Lanir, A.; Soudry, M.; Machtey, Y.; Schreiber, R.; Benmair, J.

    1986-02-01

    Thirty-two patients with diversified pathology were examined with a supraconductive NMR imager using spin echo with different TR and TE to obtain T1 and T2 weighted images. They included 20 tumors (12 primary, eight metastasis), six osteomyelitis, three fractures, two osteonecrosis, and one diffuse metabolic (Gaucher) disease. In all cases except for the stress fractures, the bone pathology was clearly visualized in spite of the normal lack of signal from the compact cortical bone. Nuclear magnetic resonance (NMR) imaging proved to be at least as sensitive as radionuclide scintigraphy but much more accurate than all other imaging procedures including computed tomography (CT) and angiography to assess the extension of the lesions, especially in tumors extended to soft tissue. This is due both to easy acquisition of sagittal and coronal sections and to different patterns of pathologic modifications of T1 and T2 which are beginning to be defined. It is hoped that more experience in clinical use of these patterns will help to discriminate between tumor extension and soft-tissue edema. We conclude that while radionuclide scintigraphy will probably remain the most sensitive and easy to perform screening test for bone pathology, NMR imaging, among noninvasive diagnostic procedures, appears to be at least as specific as CT. In addition, where the extension of the lesions is concerned, NMR imaging is much more informative than CT. In pathology of the spine, the easy visualization of the spinal cord should decrease the need for myelography.

  17. The effects of early postoperative radiation on vascularized bone grafts

    SciTech Connect

    Evans, H.B.; Brown, S.; Hurst, L.N. )

    1991-06-01

    The effects of early postoperative radiation were assessed in free nonvascularized and free vascularized rib grafts in the canine model. The mandibles of one-half of the dogs were exposed to a cobalt 60 radiation dose of 4080 cGy over a 4-week period, starting 2 weeks postoperatively. The patency of vascularized grafts was confirmed with bone scintigraphy. Histological studies, including ultraviolet microscopy with trifluorochrome labeling, and histomorphometric analyses were performed. Osteocytes persist within the cortex of the vascularized nonradiated grafts to a much greater extent than in nonvascularized, nonradiated grafts. Cortical osteocytes do not persist in either vascularized or nonvascularized grafts subjected to radiation. New bone formation is significantly retarded in radiated grafts compared with nonradiated grafts. Periosteum and endosteum remained viable in the radiated vascularized grafts, producing both bone union and increased bone turnover, neither of which were evident to any significant extent in nonvascularized grafts. Bone union was achieved in vascularized and non-vascularized nonradiated bone. In the radiated group of dogs, union was only seen in the vascularized bone grafts.

  18. 99Tcm-pyrophosphate myocardial scintigraphy: the role of volume-rendered three-dimensional imaging in the diagnosis of acute myocardial infarction.

    PubMed

    Howarth, D M; Southee, A E; Allen, L W; Tan, P S

    1995-07-01

    The aim of this study was to evaluate the role of volume-rendered three-dimensional imaging in the diagnosis of acute myocardial infarction (AMI) using 99Tcm-pyrophosphate (99Tcm-PYP) scintigraphy in a diagnostically difficult group of patients. In total, 117 patients were studied using planar, single photon emission tomography (SPET) and 3-D volume-rendered imaging performed 3 h after receiving 555 MBq (15 mCi) of 99Tcm-PYP intravenously. 555MBq (15 mCi) of 99Tcm-PYP intravenously. Two teams of physicians reported in a blinded and random fashion on each planar, SPET and 3-D rotating image study. Individual reports were compared with reports that used all three imaging modalities in combination. Observer reproducibility was between 85 and 90% and inter-observer team agreement was between 87 and 91%. A score based on clinical history, electrocardiography, serum cardiac enzyme levels and cardiac risk factors was validated and used as a de facto 'gold standard' for AMI for 75 of the subjects for whom all these details were available. The sensitivity, specificity and overall accuracy of combined planar, SPET and 3-D rotating image modalities were all 84%. Analysis of each modality in isolation showed SPET imaging to have the highest sensitivity (74%) and specificity (89%). In combination with SPET and planar imaging, 3-D rotation image presentation increases diagnostic sensitivity without appreciably altering overall diagnostic accuracy. 99Tcm-PYP myocardial SPET imaging shows good utility in the diagnosis of AMI in diagnostically difficult patients. PMID:7478393

  19. Perfusion Scintigraphy and Patient Selection for Lung Volume Reduction Surgery

    PubMed Central

    Chandra, Divay; Lipson, David A.; Hoffman, Eric A.; Hansen-Flaschen, John; Sciurba, Frank C.; DeCamp, Malcolm M.; Reilly, John J.; Washko, George R.

    2010-01-01

    Rationale: It is unclear if lung perfusion can predict response to lung volume reduction surgery (LVRS). Objectives: To study the role of perfusion scintigraphy in patient selection for LVRS. Methods: We performed an intention-to-treat analysis of 1,045 of 1,218 patients enrolled in the National Emphysema Treatment Trial who were non–high risk for LVRS and had complete perfusion scintigraphy results at baseline. The median follow-up was 6.0 years. Patients were classified as having upper or non–upper lobe–predominant emphysema on visual examination of the chest computed tomography and high or low exercise capacity on cardiopulmonary exercise testing at baseline. Low upper zone perfusion was defined as less than 20% of total lung perfusion distributed to the upper third of both lungs as measured on perfusion scintigraphy. Measurements and Main Results: Among 284 of 1,045 patients with upper lobe–predominant emphysema and low exercise capacity at baseline, the 202 with low upper zone perfusion had lower mortality with LVRS versus medical management (risk ratio [RR], 0.56; P = 0.008) unlike the remaining 82 with high perfusion where mortality was unchanged (RR, 0.97; P = 0.62). Similarly, among 404 of 1,045 patients with upper lobe–predominant emphysema and high exercise capacity, the 278 with low upper zone perfusion had lower mortality with LVRS (RR, 0.70; P = 0.02) unlike the remaining 126 with high perfusion (RR, 1.05; P = 1.00). Among the 357 patients with non–upper lobe–predominant emphysema (75 with low and 282 with high exercise capacity) there was no improvement in survival with LVRS and measurement of upper zone perfusion did not contribute new prognostic information. Conclusions: Compared with optimal medical management, LVRS reduces mortality in patients with upper lobe–predominant emphysema when there is low rather than high perfusion to the upper lung. PMID:20538961

  20. Rare case of thoracic kidney detected by renal scintigraphy.

    PubMed

    Natarajan, Aravintho; Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2016-01-01

    Intrathoracic kidney is a rare congenital abnormality with lowest frequency among all renal ectopias. Patients with thoracic kidneys are usually asymptomatic, and the condition is usually discovered incidentally during radiological evaluation for other conditions or during thoracic surgery. We report a case of a 62-year-old male who was referred to our department for renal scintigraphy for a nonvisualized left kidney on ultrasonography report. Both Tc-99m dimercaptosuccinic acid and diethylenetriaminepentaacetic acid scans revealed a left thoracic kidney which was confirmed by CT scan of the thorax and abdomen. PMID:27385896

  1. Rare case of thoracic kidney detected by renal scintigraphy

    PubMed Central

    Natarajan, Aravintho; Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2016-01-01

    Intrathoracic kidney is a rare congenital abnormality with lowest frequency among all renal ectopias. Patients with thoracic kidneys are usually asymptomatic, and the condition is usually discovered incidentally during radiological evaluation for other conditions or during thoracic surgery. We report a case of a 62-year-old male who was referred to our department for renal scintigraphy for a nonvisualized left kidney on ultrasonography report. Both Tc-99m dimercaptosuccinic acid and diethylenetriaminepentaacetic acid scans revealed a left thoracic kidney which was confirmed by CT scan of the thorax and abdomen. PMID:27385896

  2. Papillary carcinoma in ectopic thyroid detected by Tl-201 scintigraphy

    SciTech Connect

    Michigishi, T.; Mizukami, Y.; Mura, T.; Nomura, T.; Watanabe, K.; Tonami, N.; Hisada, K. )

    1991-05-01

    A 37-year-old man with papillary carcinoma in an ectopic thyroid is presented. Excisional biopsy revealed the cervical mass to be a metastasis from thyroid cancer. X-ray, ultrasonography, and computed tomography, however, failed to identify the primary tumor in the thyroid. Incidental TI-201 uptake was noted in the midline of the anterior neck, and a palpable nodule was discovered in this area. Fine needle aspiration cytology demonstrated Class V papillary adenocarcinoma, and subsequent surgery confirmed a papillary carcinoma in the ectopic thyroid. This case suggests the usefulness of TI-201 scintigraphy for the detection of ectopic thyroid malignancy.

  3. Hepatobiliary scintigraphy in patients receiving hepatic artery infusion chemotherapy

    SciTech Connect

    Housholder, D.F.; Hynes, H.E.; Dakhil, S.R.; Marymont, J.V.

    1985-05-01

    Hepatic artery infusion chemotherapy is used in the treatment of certain selected hepatic tumors, especially metastatic adenocarcinoma of the colon. Chemical cholecystitis has been recognized recently as a complication of hepatic artery infusion chemotherapy. The authors performed hepatobiliary scans on ten patients receiving hepatic artery infusion chemotherapy. All ten patients had abnormal hepatobiliary scintigraphy. They present case reports of three patients with abnormal hepatobiliary scans who have required cholecystectomy for symptoms of chemical cholecystitis to illustrate the clinical, scintigraphic, and pathologic findings in these patients.

  4. Detection of deep venous thrombosis by indium-111 leukocyte scintigraphy

    SciTech Connect

    D'Alonzo, W.A. Jr.; Alavi, A.

    1986-05-01

    Indium-111-labeled leukocyte ((/sup 111/In)WBC) scintigraphy has been used successfully for detection of inflammation. Occasionally, noninflammatory collections of white blood cells such as hematomas or hemorrhage have been localized. We report a case in which unsuspected femoral deep venous thrombosis was diagnosed on an (/sup 111/In)WBC leukocyte scan performed for detection of osteomyelitis. Readers are advised to avoid interpreting all vascular (/sup 111/In)WBC localization as necessarily infectious. This may be of particular significance in patients with vascular grafts.

  5. Knife and impact cutting of lamb bone.

    PubMed

    King, M J

    1999-05-01

    The forces and hence fracture energies required to cut bone are presented in this paper and the merits of cutting with a high speed blade are considered. A plain knife blade was used to cut cancellous and compact lamb bone using three different methods. A microtome was used to produce a range of cut thicknesses which enabled the fracture energy to be separated into friction, surface fracture and plastic deformation energies. A tensile test machine was used to produce thicker off-cuts so that the energy required to cut through full sections of bone could be determined. A high speed rail gun was used to cut at speeds up to 130 m/s. The energy required to cut bone did not change with blade speed. However, the energies measured during the cutting varied over a wide range. In situations in which the surface of the cut bone exhibited a very uneven surface high energy was required, whereas when the resulting cut surface was planar the cutting energy was low. A light weight blade which impacts the bone at high speed will transmit a small impulse to the carcass which may be absorbed without transmitting strain to the muscle/connective tissue. This may allow the development of a high speed knife which will cut bone without excessively damaging the meat surrounding the cut. PMID:22062140

  6. Bone marrow transplant

    MedlinePlus

    Transplant - bone marrow; Stem cell transplant; Hematopoietic stem cell transplant; Reduced intensity nonmyeloablative transplant; Mini transplant; Allogenic bone marrow transplant; Autologous bone marrow transplant; ...

  7. Bone marrow transplant

    MedlinePlus

    Transplant - bone marrow; Stem cell transplant; Hematopoietic stem cell transplant; Reduced intensity, nonmyeloablative transplant; Mini transplant; Allogenic bone marrow transplant; Autologous bone marrow transplant; Umbilical ...

  8. Integration of planar transformer and/or planar inductor with power switches in power converter

    DOEpatents

    Chen, Kanghua; Ahmed, Sayeed; Zhu, Lizhi

    2007-10-30

    A power converter integrates at least one planar transformer comprising a multi-layer transformer substrate and/or at least one planar inductor comprising a multi-layer inductor substrate with a number of power semiconductor switches physically and thermally coupled to a heat sink via one or more multi-layer switch substrates.

  9. When to perform positron emission tomography/computed tomography or radionuclide bone scan in patients with recently diagnosed prostate cancer.

    PubMed

    Caldarella, Carmelo; Treglia, Giorgio; Giordano, Alessandro; Giovanella, Luca

    2013-01-01

    Skeletal metastases are very common in prostate cancer and represent the main metastatic site in about 80% of prostate cancer patients, with a significant impact in patients' prognosis. Early detection of bone metastases is critical in the management of patients with recently diagnosed high-risk prostate cancer: radical treatment is recommended in case of localized disease; systemic therapy should be preferred in patients with distant secondary disease. Bone scintigraphy using radiolabeled bisphosphonates is of great importance in the management of these patients; however, its main drawback is its low overall accuracy, due to the nonspecific uptake in sites of increased bone turnover. Positron-emitting radiopharmaceuticals, such as fluorine-18-fluorodeoxyglucose, choline-derived drugs (fluorine-18-fluorocholine and carbon-11-choline) and sodium fluorine-18-fluoride, are increasingly used in clinical practice to detect metastatic spread, and particularly bone involvement, in patients with prostate cancer, to reinforce or substitute information provided by bone scan. Each radiopharmaceutical has a specific mechanism of uptake; therefore, diagnostic performances may differ from one radiopharmaceutical to another on the same lesions, as demonstrated in the literature, with variable sensitivity, specificity, and overall accuracy values in the same patients. Whether bone scintigraphy can be substituted by these new methods is a matter of debate. However, greater radiobiological burden, higher costs, and the necessity of an in-site cyclotron limit the use of these positron emission tomography methods as first-line investigations in patients with prostate cancer: bone scintigraphy remains the mainstay for the detection of bone metastases in current clinical practice. PMID:23861598

  10. Early Indium-111 antimyosin scintigraphy for assessment of regional wall motion asynergy on discharge after myocardial infarction

    SciTech Connect

    van Vlies, B.; Baas, J.; Visser, C.A.; van Royen, E.; Delemarre, B.J.; Bot, H.; Dunning, A.J. )

    1990-01-01

    To assess the relation between early Indium-111 monoclonal antimyosin antibody scintigraphy and degree of regional asynergy on discharge, 38 patients with a first acute myocardial infarct were studied (18 anterior, 20 inferoposterior infarctions). In 21 patients thrombolytic therapy was administered. On the first day of myocardial infarction, 80 MBq Indium-111 Antimyosin was injected. Planar images, anterior, lateral and left anterior oblique, were made 24 hours later. Localized myocardial uptake was present in 37/38 patients, and was evaluated for Count Density Index (count density of infarct zone/left lung count density) in the left anterior oblique images, which displayed the infarct zone well. Regional asynergy on discharge was evaluated by cross-sectional echocardiography and defined mild (hypokinesia) or severe (akinesia or dyskinesia). Count density index was significantly lower in 15 patients with mild asynergy, compared with 22 patients with severe asynergy (1.61 +/- 0.25 vs. 2.42 +/- 0.40, p less than 0.001). This difference was present in both patient groups treated with or without thrombolysis. We conclude that early count density index, reflecting the amount of local necrosis, is highly correlated to the ultimate degree of wall motion impairment.

  11. Parathyroid scintigraphy in patients with primary hyperparathyroidism: 99mTc sestamibi SPECT and SPECT/CT.

    PubMed

    Eslamy, Hedieh K; Ziessman, Harvey A

    2008-01-01

    The clinical diagnosis of primary hyperparathyroidism is based largely on serum laboratory test results, as patients often are asymptomatic. Surgery, often with bilateral exploration of the neck, has been considered the definitive treatment for symptomatic disease. However, given that approximately 90% of cases are due to a single parathyroid adenoma, a better treatment may be the selective surgical excision of the hyperfunctioning parathyroid gland after its preoperative identification and localization at radiologic imaging. Scintigraphy and ultrasonography are the imaging modalities most often used for preoperative localization. Various scintigraphic protocols may be used in the clinical setting: Single-phase dual-isotope subtraction imaging, dual-phase single-isotope imaging, or a combination of the two may be used to obtain planar or tomographic views. Single photon emission computed tomography (SPECT) with the use of technetium-99m ((99m)Tc) sestamibi as the radiotracer, especially when combined with x-ray-based computed tomography (CT), is particularly helpful for preoperative localization: The three-dimensional functional information from SPECT is fused with the anatomic information obtained from CT. In addition, knowledge of the anatomy and embryologic development of the parathyroid glands and the pathophysiology of primary hyperparathyroidism aid in the identification and localization of hyperfunctioning glands. PMID:18794320

  12. Sports nuclear medicine. Bone imaging for lower extremity pain in athletes

    SciTech Connect

    Brill, D.R.

    1983-03-01

    Increased participation in sports by the general public has led to an increase in sports-induced injuries, including stress fractures, shin splints, arthritis, and a host of musculotendinous maladies. Bone scintigraphy with Tc-99m MDP has been used with increasing frequency in detecting stress fractures, but this study can miss certain important conditions and detect other lesions of lesser clinical significance. This paper demonstrates the spectrum of findings on bone scanning in nonacute sports trauma and offers suggestions for the optimal use of Tc-99m MDP for detecting the causes of lower extremity pain in athletes.

  13. A sign of symptomatic chronic cholecystitis on biliary scintigraphy

    SciTech Connect

    Al-Sheikh, W.; Hourani, M.; Barkin, J.S.; Clarke, L.P.; Ashkar, F.S.; Serafini, A.N.

    1983-02-01

    Five hundred patients with acute right-upper-quadrant pain underwent biliary scintigraphy with /sup 99m/Tc paraisopropyliminodiacetic acid. One hundred and thirty-four studies were reported normal (both gallbladder and activity in bowel are noted in 1 hr). Of the 134 studies reported as normal, 32 showed intestinal activity before gallbladder visualization during the first hour of the study. Sonography and/or oral cholecystography revealed that 24 patients had gallstones, and eight patients had no demonstrable pathology in the biliary system. Of the 134 studies, 102 showed visualization of the gallbladder before intestinal activity during the first hour of the study. Sonography and/or oral cholecystography showed that 73 patients had normal biliary system. The remaining 29 patients had gallstones. The overall sensitivity of this finding is 45%, the specificity is 90%, and the accuracy is 73%. In this group of symptomatic patients, the appearance of intestinal activity before gallbladder activity on biliary scintigraphy warrants further evaluation of these patients by sonography and/or oral cholecystography.

  14. Hepatobiliary scintigraphy in patients receiving hepatic artery infusion chemotherapy

    SciTech Connect

    Housholder, D.F.; Hynes, H.E.; Dakhil, S.R.; Marymont, J.H. Jr.

    1984-01-01

    Two patients receiving hepatic artery infusion chemotherapy (HAIC) required cholecystectomy for both acute and chronic cholecystitis with cholelithiasis suggesting chemical cholecystitis. To evaluate the incidence of gall bladder dysfunction in patients receiving HAIC, the authors performed hepatobiliary scintigraphy using Tc-99m DISIDA or PIPIDA on eight patients receiving HAIC through an indwelling hepatic artery catheter and Infusaid (trademark) pump. In 7 of 8 patients, there was non-visualization of the gall bladder throughout the hepatobiliary study. In the eighth patient, the gall bladder visualized at 2 hr. One patient with non-visualization of the gall bladder at 4 hr developed acute symptoms requiring cholecystectomy which showed acute and chronic cholecystitis with cholethiasis. There was prominent sclerosis which was thought to be due to chemical cholecystitis as well as cholelithiasis. In all 10 patients, no evidence of cholecystitis had been observed during the surgical placement of the hepatic artery catheter and Infusaid pump. The hepatobiliary scintigraphic finding of gall bladder dysfunction in all eight patients studied is most likely due to chemical cholecystitis from HAIC. This series suggests that chemical cholecystitis is common during HAIC and can be identified by hepatobiliary scintigraphy. The authors consider elective cholecystectomy during the operative placement of the hepatic artery catheter and Infusaid pump.

  15. The role of hepatobiliary scintigraphy in cystic fibrosis.

    PubMed

    O'Connor, P J; Southern, K W; Bowler, I M; Irving, H C; Robinson, P J; Littlewood, J M

    1996-02-01

    This was a prospective open study that examined the quantitative and qualitative analysis of hepatobiliary scintigraphy (DISIDA) in detecting liver involvement in cystic fibrosis (CF). Forty-four adult and pediatric patients (median age, 12.1 years; range, 1.1-36.3 years) were divided into three groups: group 1, no evidence of liver involvement (n = 8); group 2, biochemical evidence of liver involvement on two or more occasions (n = 26); and group 3, clinical evidence of liver disease (n = 10). In groups 1 and 2, the most common qualitative scintigraphic finding was focal intrahepatic retention of tracer (26/34 patients, 12 of whom had normal findings on ultrasonography). This finding corresponds to focal cholestasis and may warrant treatment with the choleretic agent ursodeoxycholic acid (UDCA). In the group 3 patients, the abnormal qualitative scintigraphic appearances (heterogeneous uptake of tracer and nodular liver outline) added little to the findings on ultrasonography; however, these patients had a prolonged mean hepatic clearance time compared with those in groups 1 and 2 (one-way ANOVA; P < .015). It is proposed that scintigraphy with DISIDA has a role in the detection of early liver involvement in cystic fibrosis. PMID:8591853

  16. Relationship between extraosseous accumulation in bone scintigraphy with 99Tcm-HMDP and histopathology.

    PubMed

    Flores, L G; Nagamachi, S; Jinnouchi, S; Ohnishi, T; Futami, S; Nakahara, H; Tamura, S

    1998-04-01

    We assessed the relationship between 99Tcm-HMDP extraosseous accumulation (EOA), the histopathology of primary lesions and various laboratory findings. In 155 of 4824 patients, 163 EOA were noted. Of these, 33.7% were in the abdomen, 27.6% in the chest, 22.7% in the extremities, 9.8% in the pelvic area and 6.1% in the head and neck area. We found that 72.4% of EOA were due to malignant processes and 27.6% to benign processes. In the abdomen, 36.6% of the EOA were due to hepatocellular carcinoma and intestinal carcinoma. In the chest, 46.7% of EOA were a result of breast carcinoma. In the extremities, 28.7% of the EOA were due to sarcoma. The mean white blood cell count was elevated (8.0 +/- 6.3 x 10(3)) in patients with malignant processes. The mean serum haemoglobin and haematocrit in benign and malignant processes, for both males and females, were below normal values. All other laboratory findings were within normal limits. Significant differences in serum haemoglobin and haematocrit were noted between male and female patients with benign processes (P = 0.04 and P = 0.04, respectively). No other significant differences between benign and malignant processes were noted. Therefore, EOA is more frequently associated with malignant processes of primary lesions and is often accompanied by leukocytosis and anaemia. PMID:9853325

  17. Piezo Voltage Controlled Planar Hall Effect Devices.

    PubMed

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-01-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials. PMID:27329068

  18. Planar quantum squeezing and atom interferometry

    SciTech Connect

    He, Q. Y.; Drummond, P. D.; Reid, M. D.; Peng Shiguo

    2011-08-15

    We obtain a lower bound on the sum of two orthogonal spin component variances in a plane. This gives a planar uncertainty relation which holds even when the Heisenberg relation is not useful. We investigate the asymptotic, large-J limit and derive the properties of the planar quantum squeezed states that saturate this uncertainty relation. These states extend the concept of spin squeezing to any two conjugate spin directions. We show that planar quantum squeezing can be achieved experimentally as the ground state of a Bose-Einstein condensate in two coupled potential wells with a critical attractive interaction. These states reduce interferometric phase noise at all phase angles simultaneously. This is useful for one-shot interferometric phase measurements where the measured phase is completely unknown. Our results can also be used to derive entanglement criteria for multiple spins J at separated sites, with applications in quantum information.

  19. Piezo Voltage Controlled Planar Hall Effect Devices

    PubMed Central

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K. W.; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-01-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials. PMID:27329068

  20. The Feynman Identity for Planar Graphs

    NASA Astrophysics Data System (ADS)

    da Costa, G. A. T. F.

    2016-08-01

    The Feynman identity (FI) of a planar graph relates the Euler polynomial of the graph to an infinite product over the equivalence classes of closed nonperiodic signed cycles in the graph. The main objectives of this paper are to compute the number of equivalence classes of nonperiodic cycles of given length and sign in a planar graph and to interpret the data encoded by the FI in the context of free Lie superalgebras. This solves in the case of planar graphs a problem first raised by Sherman and sets the FI as the denominator identity of a free Lie superalgebra generated from a graph. Other results are obtained. For instance, in connection with zeta functions of graphs.

  1. A catastrophe theory model of planar orientation

    SciTech Connect

    Wright, M.W.; Deacon, G.E.

    2000-06-01

    The manipulation of planar objects using linear fences is of interest in robotics and parts feeding applications. The global behavior of such systems can be characterized graphically using Brost's push stability diagram (PSD). Previously, the authors have shown specifically under what conditions this representation undergoes qualitative, topological transitions corresponding to globally distinct behavioral regimes. In this paper, they show that these insights form a united whole when viewed from the perspective of catastrophe theory. The key result is that a planar object being pushed by a fence under the assumption of Coulomb friction is functionally equivalent to a gravitational catastrophe machine. Qualitative changes in global behavior are thus explained as catastrophes as singularities are encountered on a discriminant surface due to smooth changes in parameters. Catastrophe theory thus forms part of a computational theory of planar orientation, the aim of which is to understand such systems and make predictions about their behavior.

  2. Bone Marrow Diseases

    MedlinePlus

    Bone marrow is the spongy tissue inside some of your bones, such as your hip and thigh bones. ... the platelets that help with blood clotting. With bone marrow disease, there are problems with the stem cells ...

  3. Bone Marrow Transplantation

    MedlinePlus

    Bone marrow is the spongy tissue inside some of your bones, such as your hip and thigh bones. ... platelets, which help the blood to clot. A bone marrow transplant is a procedure that replaces a person's ...

  4. Genetics of Bone Density

    MedlinePlus

    ... study linked 32 novel genetic regions to bone mineral density. The findings may help researchers understand why ... or treating osteoporosis. Bones are made of a mineral and protein scaffold filled with bone cells. Bone ...

  5. Calcium and bones

    MedlinePlus

    Bone strength and calcium ... calcium (as well as phosphorus) to make healthy bones. Bones are the main storage site of calcium in ... your body does not absorb enough calcium, your bones can get weak or will not grow properly. ...

  6. Bone biopsy (image)

    MedlinePlus

    A bone biopsy is performed by making a small incision into the skin. A biopsy needle retrieves a sample of bone and it ... examination. The most common reasons for bone lesion biopsy are to distinguish between benign and malignant bone ...

  7. Bone lesion biopsy

    MedlinePlus

    Bone biopsy; Biopsy - bone ... needle is gently pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  8. Congenital renal anomaly: evaluation with 99mTc-dimercaptosuccinic acid renal scintigraphy

    SciTech Connect

    Hosokawa, S.; Kawamura, J.; Tomoyoshi, T.; Yoshida, O.

    1983-05-01

    Technetium 99m-2,3, dimercaptosuccinic acid (99mTc-DMSA) preferentially accumulates in the renal cortex, demonstrating functioning cortical mass. We used 99mTc-DMSA renal scintigraphy in ten patients with horseshoe kidneys and five patients with unilateral fused kidneys. The results show that 99mTc-DMSA renal scintigraphy reliably establishes the diagnosis of horseshoe kidney and clearly shows the isthmus, which is very essential for proper management. The technique also aids in the definitive assessment of separate kidney function and of total radionuclide uptake is possible using 99mTc-DMSA scintigraphy.

  9. 123I-Metaiodobenzylguanidine Myocardial Scintigraphy in Lewy Body-Related Disorders: A Literature Review

    PubMed Central

    Chung, Eun Joo; Kim, Sang Jin

    2015-01-01

    Lewy body-related disorders are characterized by the presence of Lewy bodies and Lewy neurites, which have abnormal aggregations of α-synuclein in the nigral and extranigral areas, including in the heart. 123I-metaiodobenzylguanidine (MIBG) scintigraphy is a well-known tool to evaluate cardiac sympathetic denervation in the Lewy body-related disorders. MIBG scintigraphy showed low uptake of MIBG in the Lewy body-related disorders, including Parkinson’s disease, dementia with Lewy bodies, pure autonomic failure and rapid eye movement sleep behavior disorder. This review summarizes previous results on the diagnostic applications of MIBG scintigraphy in Lewy body-related disorders. PMID:26090077

  10. Comparative study of ultrasonography and scintigraphy in liver metastases detection in cases of colorectal carcinoma

    SciTech Connect

    Arnaud, J.P.; Daly, R.; Leguillou, A.; Adloff, M. )

    1982-02-01

    A comparative study has been realized to test the accuracy of ultrasonography and scintigraphy for detecting the presence of liver metastases in 305 patients with colorectal carcinomas. Presence or absence of hepatic metastases has been affirmed by laparotomy and biopsy. In the 47 cases with metastases, the sensitivity of ultrasonography was 93%, that of scintigraphy being 76%. In 258 cases without metastases the specificity of ultrasonography was 97%, that of scintigraphy being 92%. These results, confirmed by report in the published literature, show that ultrasonography should be the first examination for suspected hepatic metastases.

  11. The role of Tc-99m RBC scintigraphy in the differential diagnosis of orbital cavernous hemangioma.

    PubMed

    Sayit, E; Durak, I; Capakaya, G; Yilmaz, M; Durak, H

    2001-04-01

    The cavernous hemangioma is the most common benign orbital tumor in adults. Its presentation is during the forth to fifth decades with a slowly progressive unilateral proptosis. Intraconal cavernous hemangiomas may be difficult to differentiate from other intraconal lesions such as schwannomas, meningiomas and hemangiopericytomas. We report a case of orbital cavernous hemangioma diagnosed by Tc-99m RBC scintigraphy. Tc-99m RBC scintigraphy revealed a typical scintigraphic pattern in which there is intense focally increased uptake on the delayed image. We conclude that Tc-99m RBC scintigraphy can be a useful method in the differential diagnosis of orbital cavernous hemangioma as in hepatic hemangioma. PMID:11448074

  12. Pinning of flux lines by planar defects

    NASA Astrophysics Data System (ADS)

    Petković, Aleksandra; Emig, Thorsten; Nattermann, Thomas

    2009-06-01

    The influence of randomly distributed point impurities and planar defects on order and transport in type-II superconductors and related systems is studied. It is shown that the Bragg glass phase is unstable with respect to planar defects. Even a single weak defect plane oriented parallel to the magnetic field as well as to one of the main axes of the Abrikosov flux-line lattice is a relevant perturbation in the Bragg glass. A defect that is aligned with the magnetic field restores the flux density oscillations, which decay algebraically with the distance from the defect. The theory exhibits striking similarities to the physics of a Luttinger liquid with a frozen impurity. The exponent for the flux-line creep in the direction perpendicular to a relevant defect is derived. We find that the flux-line lattice exhibits in the presence of many randomly distributed parallel planar defects aligned to the magnetic field a glassy phase which we call planar glass. The planar glass is characterized by diverging shear and tilt moduli, a transverse Meissner effect, and resistance against shear deformations. We also obtain sample-to-sample fluctuations of the longitudinal magnetic susceptibility and an exponential decay of translational long-range order in the direction perpendicular to the defects. The flux creep perpendicular to the defects leads to a nonlinear resistivity ρ(J→0)˜exp[-(JD/J)3/2] . Strong planar defects enforce arrays of dislocations that are located at the defects with a Burgers vector parallel to the defects in order to relax shear strain.

  13. Electron-optical systems for planar gyrotrons

    SciTech Connect

    Manuilov, V. N.; Zaslavsky, V. Yu.; Ginzburg, N. S.; Glyavin, M. Yu.; Kuftin, A. N.; Zotova, I. V.

    2014-02-15

    The methodology of designing an electron-optical system (EOS) that forms sheet helical electron beams (HEBs) for high-power gyrotrons is developed. As an example, we consider the EOS for a 140-GHz gyrotron operated at the first harmonic of the cyclotron frequency with an accelerating voltage of 50 kV, a beam current of 30 A, and a magnetic field compression of 36. A planar geometry of the magnetron-injection gun (MIG) is suggested. The adiabatic theory of MIGs modified for the planar geometry of EOS is used for preliminary estimations of MIG parameters. Numerical simulation of the HEB properties based on the CST STUDIO SUITE 3D code is performed to find the optimal configuration of a planar MIG. The accuracy of the calculated data is discussed. The main factors that affect the HEB quality are considered. It is shown that a sheet HEB with a pitch-factor of 1.3 and velocity spread not exceeding 25%–30% can be formed; this is quite acceptable for high-efficiency operation of modern gyrotrons. Calculation of the beam-wave interaction with the obtained HEB parameters proved that a high output power with a sufficiently good efficiency of about 20% can be reached. Simulations show the feasibility of the experimental implementation of a novel planar EOS and its use in short-wave planar gyrotrons. The developed technique can be used for the study and optimization of planar gyrotrons of different frequency bands and power levels.

  14. Recirculating planar magnetrons: simulations and experiment

    SciTech Connect

    Franzi, Matthew; Gilgenbach, Ronald; French, David; Lau, Y.Y.; Simon, David; Hoff, Brad; Luginsland, John W.

    2011-07-01

    The Recirculating Planar Magnetron (RPM) is a novel crossed-field device whose geometry is expected to reduce thermal load, enhance current yield as well as ease the geometric limitations in scaling to high RF frequencies as compared to the conventional cylindrical magnetrons. The RPM has two different adaptations: A. Axial B field and radial E field; B. Radial B field and axial E field. The preliminary configuration (A) to be used in experiments at the University of Michigan consists of two parallel planar sections which join on either end by cylindrical regions to form a concentric extruded ellipse. Similar to conventional magnetrons, a voltage across the AK gap in conjunction with an axial magnetic field provides the electrons with an ExB drift. The device is named RPM because the drifting electrons recirculate from one planar region to the other. The drifting electrons interact with the resonantly tuned slow wave structure on the anode causing spoke formation. These electron spokes drive a RF electric field in the cavities from which RF power may be extracted to Waveguides. The RPM may be designed in either a conventional configuration with the anode on the outside, for simplified extraction, or as an inverted magnetron with the anode at the inner conductor, for fast start-up. Currently, experiments at the Pulsed Power and Microwave Laboratory at the University of Michigan are in the setup and design phase. A conventional RPM with planar cavities is to be installed on the Michigan Electron Long Beam Accelerator (MELBA) and is anticipated to operate at -200kV, 0.2T with a beam current of 1-10 kA at 1GHz. The conventional RPM consists of 12 identical planar cavities, 6 on each planar side, with simulated quality factor of 20.

  15. Normal anatomic variant: scintigraphy of the ischiopubic synchondrosis

    SciTech Connect

    Cawley, K.A.; Dvorak, A.D.; Wilmot, M.D.

    1983-01-01

    Radionuclide bone imaging in pediatric patients occasionally shows a focus of distinct localized increase of radiotracer uptake at the ischiopubic synchondrosis. Correlation of radionuclide bone images and conventional radiographs of this area in a group of pediatric patients demonstrates the positive bone scans to correlate with the period of beginning but incomplete fusion of the synchondrosis. This represents a normal phase of skeletal development that radiographically and scintigraphically may mimic disease and should not be confused with a focus of pathologic activity.

  16. Bone Quality in Paget's Disease of Bone.

    PubMed

    Singer, Frederick R

    2016-04-01

    Paget's disease of bone is produced by a localized increase in osteoclastic and osteoblastic activity which can progress slowly to involve an entire bone if untreated. A common feature is enlarged bones which are deformed, particularly in weight-bearing regions of the skeleton such as the lower extremity. Pathologic fractures may be a consequence, and nonunion of femoral fractures is not uncommon. Analyses of bone biopsies from patients with Paget's disease indicate that there is a lower, heterogeneous degree of bone mineralization and a younger tissue age than that found in control bone. Pagetic bone also has less resistance to plastic deformation and a straighter crack path than control bone. PMID:26943142

  17. Large-scale planar lightwave circuits

    NASA Astrophysics Data System (ADS)

    Bidnyk, Serge; Zhang, Hua; Pearson, Matt; Balakrishnan, Ashok

    2011-01-01

    By leveraging advanced wafer processing and flip-chip bonding techniques, we have succeeded in hybrid integrating a myriad of active optical components, including photodetectors and laser diodes, with our planar lightwave circuit (PLC) platform. We have combined hybrid integration of active components with monolithic integration of other critical functions, such as diffraction gratings, on-chip mirrors, mode-converters, and thermo-optic elements. Further process development has led to the integration of polarization controlling functionality. Most recently, all these technological advancements have been combined to create large-scale planar lightwave circuits that comprise hundreds of optical elements integrated on chips less than a square inch in size.

  18. Laser direct write of planar alkaline microbatteries

    NASA Astrophysics Data System (ADS)

    Arnold, C. B.; Kim, H.; Piqué, A.

    We are developing a laser engineering approach to fabricate and optimize alkaline microbatteries in planar geometries. The laser direct-write technique enables multicapability for adding, removing and processing material and provides the ability to pattern complicated structures needed for fabricating complete microbattery assemblies. In this paper, we demonstrate the production of planar zinc-silver oxide alkaline cells under ambient conditions. The microbattery cells exhibit 1.55-V open-circuit potentials, as expected for the battery chemistry, and show a flat discharge behavior under constant-current loads. High capacities of over 450 μAhcm-2 are obtained for 5-mm2 microbatteries.

  19. Planar Inlet Design and Analysis Process (PINDAP)

    NASA Technical Reports Server (NTRS)

    Slater, John W.; Gruber, Christopher R.

    2005-01-01

    The Planar Inlet Design and Analysis Process (PINDAP) is a collection of software tools that allow the efficient aerodynamic design and analysis of planar (two-dimensional and axisymmetric) inlets. The aerodynamic analysis is performed using the Wind-US computational fluid dynamics (CFD) program. A major element in PINDAP is a Fortran 90 code named PINDAP that can establish the parametric design of the inlet and efficiently model the geometry and generate the grid for CFD analysis with design changes to those parameters. The use of PINDAP is demonstrated for subsonic, supersonic, and hypersonic inlets.

  20. BONE BANKS

    PubMed Central

    de Alencar, Paulo Gilberto Cimbalista; Vieira, Inácio Facó Ventura

    2015-01-01

    Bone banks are necessary for providing biological material for a series of orthopedic procedures. The growing need for musculoskeletal tissues for transplantation has been due to the development of new surgical techniques, and this has led to a situation in which a variety of hospital services have been willing to have their own source of tissue for transplantation. To increase the safety of transplanted tissues, standards for bone bank operation have been imposed by the government, which has limited the number of authorized institutions. The good performance in a bone bank depends on strict control over all stages, including: formation of well-trained harvesting teams; donor selection; conducting various tests on the tissues obtained; and strict control over the processing techniques used. Combination of these factors enables greater scope of use and numbers of recipient patients, while the incidence of tissue contamination becomes statistically insignificant, and there is traceability between donors and recipients. This paper describes technical considerations relating to how a bone bank functions, the use of grafts and orthopedic applications, the ethical issues and the main obstacles encountered. PMID:27026958

  1. Broken bone

    MedlinePlus

    ... from a height Motor vehicle accidents Direct blow Child abuse Repetitive forces, such as those caused by running, ... you can clearly see a deformity, assume the child has a broken bone and get medical help. Prevention Take the following steps to reduce your risk ...

  2. Emerging strategies and therapies for treatment of Paget’s disease of bone

    PubMed Central

    Michou, Laëtitia; Brown, Jacques P

    2011-01-01

    Paget’s disease of bone (PDB) is a progressive monostotic or polyostotic metabolic bone disease characterized by focal abnormal bone remodeling, with increased bone resorption and excessive, disorganized, new bone formation. PDB rarely occurs before middle age, and it is the second most frequent metabolic bone disorder after osteoporosis, affecting up to 3% of adults over 55 years of age. One of the most striking and intriguing clinical features is the focal nature of the disorder, in that once the disease is established within a bone, there is only local spread within that bone and no systemic dissemination. Despite many years of intense research, the etiology of PDB has still to be conclusively determined. Based on a detailed review of genetic and viral factors incriminated in PDB, we propose a unifying hypothesis from which we can suggest emerging strategies and therapies. PDB results in weakened bone strength and abnormal bone architecture, leading to pain, deformity or, depending on the bone involved, fracture in the affected bone. The diagnostic assessment includes serum total alkaline phosphatase, total body bone scintigraphy, skull and enlarged view pelvis x-rays, and if needed, additional x-rays. The ideal therapeutic option would eliminate bone pain, normalize serum total alkaline phosphatase with prolonged remission, heal radiographic osteolytic lesions, restore normal lamellar bone, and prevent recurrence and complications. With the development of increasingly potent bisphosphonates, culminating in the introduction of a single intravenous infusion of zoledronic acid 5 mg, these goals of treatment are close to being achieved, together with long-term remission in almost all patients. Based on the recent pathophysiological findings, emerging strategies and therapies are reviewed: ie, pulse treatment with zoledronic acid; denosumab, a fully human monoclonal antibody directed against RANK ligand; tocilizumab, an interleukin-6 receptor inhibitor; odanacatib

  3. Evaluation of the severity of traumatic rhabdomyolysis using technetium-99m pyrophosphate scintigraphy.

    PubMed

    Chang, H R; Kao, C H; Lian, J D; Shu, K H; Cheng, C H; Wu, M J; Chen, C H

    2001-01-01

    A quantitative scoring method was designed to assess the extent of muscle damage. Technetium-99m pyrophosphate (99mTc-PYP) scintigraphy was performed for 9 patients experiencing crush injury in the Chichi (Taiwan) earthquake. The magnitude of muscle uptake of 99mTc-PYP was graded as follows: grade 0, less than bone radioactivity (BRA); grade 1, equal to BRA; grade 2, higher than BRA; or grade 3, greatly higher than BRA. The area of muscle injury was estimated according to the rule of nines. The sum of the muscle injury size multiplied by its corresponding grading was defined as the anterior or posterior score according to the anterior or posterior images. Each image was interpreted by two physicians and average anterior and posterior scores were calculated. The muscle score was defined as the geometric mean of the average anterior and posterior scores. Significant correlations were obtained between the muscle score and duration of time trapped (r = 0.868, p < 0.01), peak serum creatine kinase level (r = 0.866, p < 0.01), peak serum phosphorus level (r = 0.877, p < 0.01) and number of hospital days (r = 0.875, p < 0.01). A negative correlation between the muscle score and blood pH (r = -0.706, p < 0.01) was also observed. We concluded that this scoring method may be used as an adjunct for evaluating the locations of trauma and the severity of crush syndrome, and for predicting the duration of hospital stay. PMID:11423690

  4. The problem of the patient with thyroglobulin elevation but negative iodine scintigraphy: the TENIS syndrome.

    PubMed

    Silberstein, Edward B

    2011-03-01

    The available data upon which to act in caring for patients with functioning thyroid cancer and thyroglobulin elevation/negative iodine scintigraphy (TENIS) are imperfect, almost never coming from randomized, blinded studies. When the serum thyroglobulin exceeds 2-10 ng/mL, one should use the latest imaging equipment available to find metastatic disease, especially in areas in which it is potentially resectable, ie, neck, bone, and occasionally brain, and collaborate with an experienced surgeon in removing such metastases. If one cannot locate operable metastases and/or tumor location remains elusive, empiric high-dose (131)I therapy, preceded by dosimetry, should be considered. There are no randomized studies to prove that this treatment prolongs life, although there is definite evidence of cell killing, because the serum thyroglobulin level frequently diminishes after radioiodine therapy. In selected cases External beam radiotherapy will be helpful when the tumor has been located but cannot be fully removed, for example, with invasion of the trachea, spine, or muscles. There are several tyrosine kinase inhibitors that have shown some effectiveness against the TENIS syndrome, but these should ideally be used in the context of a clinical trial. Tyrosine kinase inhibitor drugs should be preferred to conventional chemotherapy at this time; data on lenalidominde have only appeared in abstract form. The return of NIS function, to permit functioning thyroid cancer with the TENIS syndrome to again concentrate therapeutic amounts of (131)I, remains an elusive goal, with few drugs showing real promise. Gene therapy to restore the function of the NIS gene and enhance cellular immunomodulatory and tumor suppressive activity has not yet succeeded clinically. Physicians caring for patients with the TENIS syndrome are urged to enter them into clinical therapeutic studies whenever possible. PMID:21272685

  5. Intracoronary Infusion of Autologous CD133+ Cells in Myocardial Infarction and Tracing by Tc99m MIBI Scintigraphy of the Heart Areas Involved in Cell Homing

    PubMed Central

    Kurbonov, Ubaidullo; Dustov, Abdusamad; Barotov, Alisher; Khidirov, Murtazokul; Mirojov, Giesidin; Rahimov, Zikrie; Navjuvonov, Navjuvon; Rizoev, Eraj; Olimov, Nasim; Goibov, Alijon; Karim-Zade, Bakhtovar; Rakhmatov, Mukim; Muminjonov, Suhayli; Didari, Azadeh; Irgasheva, Jamila; Bobokhojaev, Oktam; Gulmuradov, Tashpulat; Therwath, Amu; Rakhmonov, Sohibnazar; Mirshahi, Massoud

    2013-01-01

    CD133 mesenchymal cells were enriched using magnetic microbead anti-CD133 antibody from bone marrow mononuclear cells (BMMNCs). Flow cytometry and immunocytochemistry analysis using specific antibodies revealed that these cells were essentially 89 ± 4% CD133+ and 8 ± 5% CD34+. CD133+/CD34+ BMMNCs secrete important bioactive proteins such as cardiotrophin-1, angiogenic and neurogenic factors, morphogenetic proteins, and proinflammatory and remodeling factors in vitro. Single intracoronary infusions of autologous CD133+/CD34+ BMMNCs are effective and reduce infarct size in patients as analyzed by Tc99m MIBI myocardial scintigraphy. The majority of patients were treated via left coronary artery. Nine months after cell therapy, 5 out of 8 patients showed a net positive response to therapy in different regions of the heart. Uptake of Tc99 isotope and revitalization of the heart area in inferoseptal region are more pronounced (P = 0.016) as compared to apex and anterosptal regions after intracoronary injection of the stem cells. The cells chosen here have the properties essential for their potential use in cell therapy and their homing can be followed without major difficulty by the scintigraphy. The cell therapy proposed here is safe and should be practiced, as we found, in conjunction with scintigraphic observation of areas of heart which respond optimally to the infusion of autologous CD133+/CD34+ BMMNCs. PMID:23983717

  6. Targeted delivery to bone and mineral deposits using bisphosphonate ligands.

    PubMed

    Cole, Lisa E; Vargo-Gogola, Tracy; Roeder, Ryan K

    2016-04-01

    The high concentration of mineral present in bone and pathological calcifications is unique compared with all other tissues and thus provides opportunity for targeted delivery of pharmaceutical drugs, including radiosensitizers and imaging probes. Targeted delivery enables accumulation of a high local dose of a therapeutic or imaging contrast agent to diseased bone or pathological calcifications. Bisphosphonates (BPs) are the most widely utilized bone-targeting ligand due to exhibiting high binding affinity to hydroxyapatite mineral. BPs can be conjugated to an agent that would otherwise have little or no affinity for the sites of interest. This article summarizes the current state of knowledge and practice for the use of BPs as ligands for targeted delivery to bone and mineral deposits. The clinical history of BPs is briefly summarized to emphasize the success of these molecules as therapeutics for metabolic bone diseases. Mechanisms of binding and the relative binding affinity of various BPs to bone mineral are introduced, including common methods for measuring binding affinity in vitro and in vivo. Current research is highlighted for the use of BP ligands for targeted delivery of BP conjugates in various applications, including (1) therapeutic drug delivery for metabolic bone diseases, bone cancer, other bone diseases, and engineered drug delivery platforms; (2) imaging probes for scintigraphy, fluorescence, positron emission tomography, magnetic resonance imaging, and computed tomography; and (3) radiotherapy. Last, and perhaps most importantly, key structure-function relationships are considered for the design of drugs with BP ligands, including the tether length between the BP and drug, the size of the drug, the number of BP ligands per drug, cleavable tethers between the BP and drug, and conjugation schemes. PMID:26482186

  7. Experimental investigation of planar ion traps

    SciTech Connect

    Pearson, C. E.; Leibrandt, D. R.; Bakr, W. S.; Mallard, W. J.; Brown, K. R.; Chuang, I. L.

    2006-03-15

    Chiaverini et al. [Quantum Inf. Comput. 5, 419 (2005)] recently suggested a linear Paul trap geometry for ion-trap quantum computation that places all of the electrodes in a plane. Such planar ion traps are compatible with modern semiconductor fabrication techniques and can be scaled to make compact, many-zone traps. In this paper we present an experimental realization of planar ion traps using electrodes on a printed circuit board to trap linear chains of tens of charged particles of 0.44 {mu}m diameter in a vacuum of 15 Pa (10{sup -1} torr). With these traps we address concerns about the low trap depth of planar ion traps and develop control electrode layouts for moving ions between trap zones without facing some of the technical difficulties involved in an atomic ion-trap experiment. Specifically, we use a trap with 36 zones (77 electrodes) arranged in a cross to demonstrate loading from a traditional four-rod linear Paul trap, linear ion movement, splitting and joining of ion chains, and movement of ions through intersections. We further propose an additional dc-biased electrode above the trap which increases the trap depth dramatically, and a planar ion-trap geometry that generates a two-dimensional lattice of point Paul traps.

  8. Duality analysis on random planar lattices.

    PubMed

    Ohzeki, Masayuki; Fujii, Keisuke

    2012-11-01

    The conventional duality analysis is employed to identify a location of a critical point on a uniform lattice without any disorder in its structure. In the present study, we deal with the random planar lattice, which consists of the randomized structure based on the square lattice. We introduce the uniformly random modification by the bond dilution and contraction on a part of the unit square. The random planar lattice includes the triangular and hexagonal lattices in extreme cases of a parameter to control the structure. A modern duality analysis fashion with real-space renormalization is found to be available for estimating the location of the critical points with a wide range of the randomness parameter. As a simple test bed, we demonstrate that our method indeed gives several critical points for the cases of the Ising and Potts models and the bond-percolation thresholds on the random planar lattice. Our method leads to not only such an extension of the duality analyses on the classical statistical mechanics but also a fascinating result associated with optimal error thresholds for a class of quantum error correction code, the surface code on the random planar lattice, which is known as a skillful technique to protect the quantum state. PMID:23214752

  9. A Planar Calculus for Infinite Index Subfactors

    NASA Astrophysics Data System (ADS)

    Penneys, David

    2013-05-01

    We develop an analog of Jones' planar calculus for II 1-factor bimodules with arbitrary left and right von Neumann dimension. We generalize to bimodules Burns' results on rotations and extremality for infinite index subfactors. These results are obtained without Jones' basic construction and the resulting Jones projections.

  10. Duality analysis on random planar lattices

    NASA Astrophysics Data System (ADS)

    Ohzeki, Masayuki; Fujii, Keisuke

    2012-11-01

    The conventional duality analysis is employed to identify a location of a critical point on a uniform lattice without any disorder in its structure. In the present study, we deal with the random planar lattice, which consists of the randomized structure based on the square lattice. We introduce the uniformly random modification by the bond dilution and contraction on a part of the unit square. The random planar lattice includes the triangular and hexagonal lattices in extreme cases of a parameter to control the structure. A modern duality analysis fashion with real-space renormalization is found to be available for estimating the location of the critical points with a wide range of the randomness parameter. As a simple test bed, we demonstrate that our method indeed gives several critical points for the cases of the Ising and Potts models and the bond-percolation thresholds on the random planar lattice. Our method leads to not only such an extension of the duality analyses on the classical statistical mechanics but also a fascinating result associated with optimal error thresholds for a class of quantum error correction code, the surface code on the random planar lattice, which is known as a skillful technique to protect the quantum state.

  11. COMPUTER ANALYSIS OF PLANAR GAMMA CAMERA IMAGES

    EPA Science Inventory



    COMPUTER ANALYSIS OF PLANAR GAMMA CAMERA IMAGES

    T Martonen1 and J Schroeter2

    1Experimental Toxicology Division, National Health and Environmental Effects Research Laboratory, U.S. EPA, Research Triangle Park, NC 27711 USA and 2Curriculum in Toxicology, Unive...

  12. Piecewise-Planar Parabolic Reflectarray Antenna

    NASA Technical Reports Server (NTRS)

    Hodges, Richard; Zawadzki, Mark

    2009-01-01

    The figure shows a dual-beam, dualpolarization Ku-band antenna, the reflector of which comprises an assembly of small reflectarrays arranged in a piecewise- planar approximation of a parabolic reflector surface. The specific antenna design is intended to satisfy requirements for a wide-swath spaceborne radar altimeter, but the general principle of piecewise-planar reflectarray approximation of a parabolic reflector also offers advantages for other applications in which there are requirements for wideswath antennas that can be stowed compactly and that perform equally in both horizontal and vertical polarizations. The main advantages of using flat (e.g., reflectarray) antenna surfaces instead of paraboloidal or parabolic surfaces is that the flat ones can be fabricated at lower cost and can be stowed and deployed more easily. Heretofore, reflectarray antennas have typically been designed to reside on single planar surfaces and to emulate the focusing properties of, variously, paraboloidal (dish) or parabolic antennas. In the present case, one approximates the nominal parabolic shape by concatenating several flat pieces, while still exploiting the principles of the planar reflectarray for each piece. Prior to the conception of the present design, the use of a single large reflectarray was considered, but then abandoned when it was found that the directional and gain properties of the antenna would be noticeably different for the horizontal and vertical polarizations.

  13. Helical axis stellarator with noninterlocking planar coils

    DOEpatents

    Reiman, A.; Boozer, A.H.

    1984-03-06

    The present invention generates stellarator fields having favorable properties (magnetic well and large rotational transform) by a simple coil system consisting only of unlinked planar non-circular coils. At large rotational transform toroidal effects on magnetic well and rotational transform are small and can be ignored. We do so herein, specializing in straight helical systems.

  14. In-111 labeled leukocyte scintigraphy in a case of multifocal candidiasis

    SciTech Connect

    Palestro, C.J.; Vega, A.; Kim, C.K.; Goldsmith, S.J. )

    1990-06-01

    The value of indium-111 labeled leukocyte scintigraphy for the diagnosis of infection in the general population is well documented; there is less information available on its role in the evaluation of the immunocompromised patient. In this study, leukocyte scintigraphy was performed on a 31-year-old immunocompromised woman who had a possible intra-abdominal abscess. No abscess was detected, but intense oral, esophageal, gastric, and vaginal uptake was observed. Candida infection was histologically confirmed at all four sites.

  15. A novel false-positive cause in testis scintigraphy in the diagnosis of testis torsion

    PubMed Central

    Koç, Zehra Pinar; Onur, Rahmi; Balci, Tansel Ansal

    2012-01-01

    Testis scintigraphy is the most reliable modality in the diagnosis of testis torsion since it directly reflects the vascularity of the testis. The ‘rim sign’ is considered as the pathognomonic sign of the missed torsion. However, there are some possible false-positive cases. In this case report, we would like to present an unexpected false-positive cause of the ‘rim sign’ in testis scintigraphy in an 18-year-old male patient. PMID:22987904

  16. Suspected acute cholecystitis. Comparison of hepatobiliary scintigraphy versus ultrasonography

    SciTech Connect

    Freitas, J.E.; Mirkes, S.H.; Fink-Bennett, D.M.; Bree, R.L.

    1982-08-01

    One hundred ninety-five patients with suspected acute cholecystitis (AC) underwent both hepatobiliary scintigraphy (HBS) and static gray-scale ultrasonography (US) to assess the relative value of each imaging modality in this clinical setting. HBS was performed after the intravenous injection of 5 mCi /sup 99m/Tc iprofenin. Abnormal HBS indicative of AC visualized the common bile duct, but not the gallbladder, within 1 to 4 hours after tracer administration. Abnormal US indicative of AC demonstrated cholelithiasis and/or gallbladder wall edema. In this series, HBS surpassed US in sensitivity (98.3% versus 81.4%), specificity (90.2% versus 60.2%), predictive value of an abnormal test (91.4% versus 51.6%), and predictive value of a normal test (100% versus 92%), HBS should be the procedure of choice for the rapid detection of AC.

  17. Abnormal thallium 201 scintigraphy during low-dose vasopressin infusions

    SciTech Connect

    Davison, R.; Kaplan, K.; Bines, A.; Spies, S.; Reed, M.T.; Lesch, M.

    1986-12-01

    Thallium 201 (/sup 201/Tl) myocardial scans were obtained in 16 patients just prior to the discontinuation of a vasopressin infusion (.1 to .2 units/min) administered for the treatment of upper gastrointestinal bleeding. Repeat scintigraphy was performed two to three hours after the vasopressin was stopped. Eleven of the 16 patients (69 percent) demonstrated areas of decreased myocardial /sup 201/Tl uptake that resolved after the infusion was stopped. Heart rate-blood pressure product was significantly lower at the time of the second scan. Autopsies were secured in three of 11 scan-positive patients: one had severe coronary artery obstruction, one nonsignificant disease, and another had normal coronary arteries. Vasopressin, even at low doses, can induce abnormalities in myocardial perfusion that are probably mediated by a direct effect on the coronary circulation. They are usually not detectable by routine monitoring techniques and conceivably form the basis for the cardiovascular morbidity associated with the use of this agent.

  18. "Finite part" electric and magnetic stored energies for planar antennas

    NASA Technical Reports Server (NTRS)

    Cockrell, C. R.

    1981-01-01

    A pair of formulas representing the time-average "finite part" electric and magnetic stored energies for planar antennas are derived. It is also shown that the asymptotic reciprocal relationship between quality factor and relative bandwidth exists for planar antennas.

  19. [The effect of anesthesia on kidney scintigraphy in the dog].

    PubMed

    Rückert, C; Meyer-Lindenberg, A; Nolte, I

    1998-07-01

    Renal scintigraphy is one of the diagnostic devices in the upper urinary tract. In 24 dogs of different age, sex and breed that--according to the usual laboratory tests--were considered healthy with respect to renal function, a renal scintigraphy with the tubular excreted tracer 99mTc-MAG3 was performed. The dogs were grouped according to three different anaesthetic regimens in order to estimate the influence of anaesthesia--which is necessary for this investigation--onto function of the normal kidney. Eight dogs were scintigraphed twice using different anaesthesia protocols. In group A (n = 22), anaesthesia was performed with a combination of atropine/diazepam/ketamine/xylazine. The reference range determined was for the period of maximal activity accumulation (Tmax) 3.2 +/- 0.8 min and for the elimination half-time (Tmax/2) 6.3 +/- 1.4 min. MAG3-clearance was 7.5 +/- 1.8 ml/min/kg. Group B (n = 5) received thiopental as a continuous intravenous infusion. Tmax was measured with 2.9 +/- 1.1 min, Tmax/2 with 4.7 +/- 1.2 min and the MAG3-clearance was 6.8 +/- 1.6 ml/min/kg. In group C (n = 5), the dogs were given propofol and halothane, and the values determined for Tmax and Tmax/2 were 4.8 +/- 2.7 and 4.8 +/- 1.4 min, respectively. The MAG3-clearance was 10.0 +/- 2.3 ml/min/kg. It is concluded that the anaesthetic regime used has a distinct influence on the reference values. PMID:9710934

  20. Joint scintigraphy using technetium-99m pyrophosphate in experimental hemarthrosis

    SciTech Connect

    Salimi, Z.; Vas, W.; Restrepo, G.

    1986-02-01

    To determine the validity of a method for induction of experimental hemarthrosis in dogs and for the nuclear imaging of hemarthrosis, serial technetium-99m pyrophosphate ((/sup 99m/Tc)PYP) flow and blood-pool scans were performed monthly in eight dogs who received bi-weekly injections of autologous blood into their femoro-tibial joints (also called stifle joint). In four control dogs, one joint was injected with saline while the other joint received only a sham injection. In addition, two dogs received intra-articular injections of autologous blood into their right stifle joint and saline into their left stifle joint. These dogs were studied with /sup 99m/TcO/sub 4/ joint scintigraphy at monthly intervals. The dogs were periodically taken out of the study and explored surgically. Pathologic examination of synovial tissue was performed. Serial radiographs were also obtained and correlated with the scan and surgical findings. There was a striking abnormal increase in blood-pool activity of (/sup 99m/Tc)PYP in the treated stifle joints, commencing at the first examination after 1 mo of blood injections and continuing for the length of the study. All radiographs showed only minimal joint space widening and some soft-tissue swelling. On pathologic examination, both grossly and microscopically, there was profuse pannus formation, with intense inflammatory infiltrate replacing much of the subsynovial fat. The scintigraphic findings correlated well with these pathologic findings. This study not only validates this method for simulating hemophilic hemarthrosis but also suggests that (/sup 99m/Tc)PYP joint scintigraphy is a simple, and noninvasive method for monitoring the early changes in hemophilic arthropathy and is superior to pertechnetate imaging for this disease process.

  1. Heterogeneity of Particle Deposition by Pixel Analysis of 2D Gamma Scintigraphy Images

    PubMed Central

    Xie, Miao; Zeman, Kirby; Hurd, Harry; Donaldson, Scott

    2015-01-01

    Abstract Background: Heterogeneity of inhaled particle deposition in airways disease may be a sensitive indicator of physiologic changes in the lungs. Using planar gamma scintigraphy, we developed new methods to locate and quantify regions of high (hot) and low (cold) particle deposition in the lungs. Methods: Initial deposition and 24 hour retention images were obtained from healthy (n=31) adult subjects and patients with mild cystic fibrosis lung disease (CF) (n=14) following inhalation of radiolabeled particles (Tc99m-sulfur colloid, 5.4 μm MMAD) under controlled breathing conditions. The initial deposition image of the right lung was normalized to (i.e., same median pixel value), and then divided by, a transmission (Tc99m) image in the same individual to obtain a pixel-by-pixel ratio image. Hot spots were defined where pixel values in the deposition image were greater than 2X those of the transmission, and cold spots as pixels where the deposition image was less than 0.5X of the transmission. The number ratio (NR) of the hot and cold pixels to total lung pixels, and the sum ratio (SR) of total counts in hot pixels to total lung counts were compared between healthy and CF subjects. Other traditional measures of regional particle deposition, nC/P and skew of the pixel count histogram distribution, were also compared. Results: The NR of cold spots was greater in mild CF, 0.221±0.047(CF) vs. 0.186±0.038 (healthy) (p<0.005) and was significantly correlated with FEV1 %pred in the patients (R=−0.70). nC/P (central to peripheral count ratio), skew of the count histogram, and hot NR or SR were not different between the healthy and mild CF patients. Conclusions: These methods may provide more sensitive measures of airway function and localization of deposition that might be useful for assessing treatment efficacy in these patients. PMID:25393109

  2. Renal anomalies in patients with turner syndrome: Is scintigraphy superior to ultrasound?

    PubMed

    Hamza, Rasha T; Shalaby, Mennatallah H; Hamed, Laith S; Abdulla, Dunya B A; Elfekky, Sahar M; Sultan, Omar M

    2016-02-01

    Renal anomalies are present in up to 30% of patients with Turner syndrome (TS). Renal ultrasound (U/S) detects anatomical renal anomalies only while renal scintigraphy detects anomalies, detects early renal malfunction, and estimates glomerular filtration rate (GFR). Thus, we aimed to assess frequency of renal abnormalities detected by scintigraphy in comparison to renal U/S in TS patients. Ninety TS patients were subjected to auxological assessment, measurement of serum creatinine; and renal U/S and scintigraphy. Renal U/S detected renal anomalies in 22.22% of patients versus 17.78 % detected by scintigraphy (P = 0.035). Scintigraphy detected renal functional abnormalities in 44.44% of patients in the form of subnormal total GFR, abnormal renogram curve pattern, improper tracer handling and perfusion; and difference in split renal function >10% between both kidneys. Patients with a 45,X karyotype had more renal functional abnormalities (56%) than those with mosaic karyotype (33.33%), P = 0.04. In conclusion, renal scintigraphy is not superior to U/S in detection of renal anomalies but is a reliable method for early detection of renal malfunction in TS patients especially those with 45,X to ensure early management to offer a better quality of life. PMID:26615819

  3. Bone banking and sterilization of bones

    NASA Astrophysics Data System (ADS)

    Minamisawa, I.; Itoman, M.; Maehara, H.; Kobayashi, A.; Watanabe, T.

    1995-08-01

    The use of banked bone (preserved allograft bone) is various and essential, because it has numerous advantages including the relative ease in retrieval a large amount of bone material and requisite shape and size. But bone banking and allografting must be promoted under obligation to stably supply safe and high-quality bone. To avoid transferring disease perfectly, irradiation sterilization is especially recommended at the present time.

  4. Aging bone in men and women: beyond changes in bone mineral density.

    PubMed

    Russo, C R; Lauretani, F; Bandinelli, S; Bartali, B; Di Iorio, A; Volpato, S; Guralnik, J M; Harris, T; Ferrucci, L

    2003-07-01

    Using peripheral quantitative computed tomography (pQCT) we assessed trabecular and cortical bone density, mass and geometric distribution at the tibia level in 512 men and 693 women, age range 20-102 years, randomly selected from the population living in the Chianti area, Tuscany, Italy. Total, trabecular and cortical bone density decreased linearly with age ( p<0.0001 in both sexes), and the slope of age-associated decline was steeper in women than in men. In men, the cortical bone area was similar in different age groups, while in women older than 60 years it was significantly smaller by approximately 1% per year. The total cross-sectional area of the bone became progressively wider with age, but the magnitude of the age-associated increment was significantly higher in men than in women ( p<0.001). The minimum moment of inertia, an index of mechanical resistance to bending, remained stable with age in men, while it was significantly lower in older compared with younger women (0.5% per year). The increase in bone cross-sectional area in aging men may contribute to the maintenance of adequate bone mechanical competence in the face of declining bone density. In women this compensatory mechanism appears to be less efficient and, accordingly, the bone mechanical competence declines with age. The geometric adaptation of increasing cross-sectional bone size is an important component in the assessment of bone mechanical resistance which is completely overlooked, and potentially misinterpreted, by traditional planar densitometry. PMID:12827220

  5. [Metastatic bone disease. Strategies for imaging].

    PubMed

    Scutellari, P N; Antinolfi, G; Galeotti, R; Giganti, M

    2003-04-01

    Skeletal metastases represent the most common malignant bone tumor. They occur mainly in adults and even more frequently in the elderly. The most common metastases in men are from prostate cancer (60%) and in women from breast cancer (70%). Other primitive tumors responsible for bone metastases are: lung, kidney, thyroid, alimentary tract, bladder, and skin. The spine and pelvis are the most common metastatic sites, due to the presence of red (haematopoietic active) bone marrow in a high amount. As a general rule, the radiographic pattern was lytic type; other aspects were osteosclerotic, mixed, lytic vs mixed and osteosclerotic vs lytic patterns. The main symptom is pain, although many bone metastases are asymptomatic. The most severe consequences are pathologic fractures and cord compression. Clinical evaluation of patients with skeletal metastases needs multimodal diagnostic imaging, able to detect lesions, to assess their extension and localization, and eventually drive the biopsy (for histo-morphological diagnosis). These techniques give different performances in terms of sensitivity and specificity; but none of the modalities alone seems to be adequate to yield a reliable diagnostic outcome. Therefore multidisciplinary cooperation is required to optimize the screening, clinical management and follow-up of the patients. In other terms, what is the efficacy of these new diagnostic tests compared to the "older" diagnostic tests? Frequently the new procedures do not replace the older one, but it is added to the diagnostic workup, thereby increasing costs without impacting the "patient's condition". The aim of the present work is to propose an "algorithm" for the detection and diagnosis of skeletal metastases, which may be applied differently in symptomatic and asymptomatic oncologic patients. Bone scintigraphy remains the first choice technique in the evaluation of asymptomatic patients, in whom skeletal metastases are supposed. Although it has a high sensitivity

  6. FRACTURE OF THE CENTRAL TARSAL BONE IN NONRACEHORSES: FOUR CASES.

    PubMed

    Knuchell, Jeannie A; Spriet, Mathieu; Galuppo, Larry D; Katzman, Scott A

    2016-07-01

    Fractures of the central tarsal bone are a rarely recognized cause of acute severe hind limb lameness in nonracehorses. Diagnosis of these fractures can be challenging and little is known about their configuration or outcome. The objectives of this retrospective case series study were to describe the clinical features, imaging findings, and outcomes of fractures of the central tarsal bone in a sample of nonracehorses. Medical records from 2001 to 2014 were searched for cases of central tarsal bone fractures in nonracehorses. All available imaging findings including radiography, ultrasound, computed tomography (CT), and/or nuclear scintigraphy were reviewed. History, clinical presentation, and outcome were collected from the records. Four horses met the inclusion criteria. All had a similar configuration as a simple nondisplaced slab fracture in a dorsomedial to plantarolateral orientation. Initial radiographs failed to reveal the fracture in three of four cases. When additional plantarolateral-dorsomedial oblique radiographic views were obtained, the fracture could be identified in all cases. Fractures of the central tarsal bone seemed to occur in a consistent dorsomedial to plantarolateral orientation in this sample of nonracehorses, which is different from the configuration previously reported in racehorses. While CT can be used for detection and assessment of these fractures, authors propose that radiography can also identify these fractures with the appropriate view. Authors recommend the use of several plantarolateral to dorsomedial radiographic projections at varying degrees of obliquity for horses with a suspected central tarsal bone fracture. PMID:26929208

  7. Splenic scintigraphy for further differentiation of unclear (68) Ga-DOTATOC-PET/CT findings: Strengths and limitations.

    PubMed

    Werner, Christoph; Winkens, Thomas; Freesmeyer, Martin

    2016-06-01

    Splenic scintigraphy has been described to be a powerful tool in unclear (68 ) Ga-DOTATOC-PET/CT findings, allowing differentiation between somatostatin receptor (Sst)-positive tissue deriving from neuroendocrine tumour (NET) and functioning splenic tissue. However, our own experiences sometimes show a lack of identification on splenic scintigraphy, especially in small lesions, leading to uncertainties regarding the safe identification of NET or splenic tissue. Here, we report on 10 cases with (68) Ga-DOTATOC-PET/CT and (99m) Tc-heat-denaturated red blood cell (HDRBC) scintigraphy and we illustrate the strengths and limitations of (99m) Tc-HDRBC scintigraphy in this context. PMID:27188232

  8. [Bone quantitative ultrasound].

    PubMed

    Matsukawa, Mami

    2016-01-01

    The conventional ultrasonic bone densitometry system can give us information of bone as ultrasonic wave velocity and attenuation. However, the data reflect both structural and material properties of bone. In order to focus only on the bone matrix properties without the effect of bone structure, studies of microscopic Brillouin scattering technique are introduced. The wave velocity in a trabecula was anisotropic and depended on the position and structure of the cancellous bone. The glycation also affected on the wave velocities in bone. As a new bone quality, the piezoelectricity of bone is also discussed. PMID:26728531

  9. Technetium-99m labelled LDL as a tracer for quantitative LDL scintigraphy. II. In vivo validation, LDL receptor-dependent and unspecific hepatic uptake and scintigraphic results.

    PubMed

    Leitha, T; Staudenherz, A; Gmeiner, B; Hermann, M; Hüttinger, M; Dudczak, R

    1993-08-01

    The purpose of this study was to determine whether the hepatic uptake of dialysed technetium-99m labelled low-density lipoprotein (99mTc-LDL) reflects the hepatic LDL receptor activity and to what extent the non-LDL receptor-dependent 99mTc-LDL uptake by non-parenchymal cells relates to the diagnostic utility of quantitative 99mTc-LDL scintigraphy of the liver. New Zealand White rabbits and Watanabe Heritable Hyperlipidaemic rabbits, which were sacrificed 24 h after simultaneous injection of 99mTc-LDL and iodine-125 labelled LDL, were clearly discriminated by their hepatic 99mTc-LDL uptake according to their genetically different hepatic LDL receptor activity. Yet the hepatic 99mTc-LDL uptake exceeded the 125I-LDL uptake in all animals. The different hepatic uptake of the tracers was elucidated in the isolated perfused rat liver and was due to rapid intracellular degradation and the release of low molecular catabolites of 125I-LDL. In contrast, 99mTc activity was trapped in the liver. Analysis of biliary 99mTc activity provided evidence for the excretion of 99mTc-labelled apolipoprotein B. The amount of biliary excreted protein-bound 99mTc was linked to total hepatic 99mTc-LDL uptake and presumably reflected LDL receptor-mediated apolipoprotein excretion. Collagenase liver perfusion in Sprague-Dawley rats 90 min following simultaneous injection of 99mTc- and 125I-LDL and subsequent cell separation by gradient centrifugation revealed that 99mTc-LDL and 125I-LDL had a comparably low uptake into non-parenchymal cells; thus its contribution can be neglected for scintigraphic purposes. Planar scintigraphy was performed in New Zealand White and Watanabe Heritable Hyperlipidaemic rabbits.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8404953

  10. Regular shock refraction in planar ideal MHD

    NASA Astrophysics Data System (ADS)

    Delmont, P.; Keppens, R.

    2010-03-01

    We study the classical problem of planar shock refraction at an oblique density discontinuity, separating two gases at rest, in planar ideal (magneto)hydrodynamics. In the hydrodynamical case, 3 signals arise and the interface becomes Richtmyer-Meshkov unstable due to vorticity deposition on the shocked contact. In the magnetohydrodynamical case, on the other hand, when the normal component of the magnetic field does not vanish, 5 signals will arise. The interface then typically remains stable, since the Rankine-Hugoniot jump conditions in ideal MHD do not allow for vorticity deposition on a contact discontinuity. We present an exact Riemann solver based solution strategy to describe the initial self similar refraction phase. Using grid-adaptive MHD simulations, we show that after reflection from the top wall, the interface remains stable.

  11. Constant field gradient planar cavity structure

    SciTech Connect

    Kang, Yoon W.; Kustom, R.L.

    1997-12-01

    A cavity structure is described having at least two opposing planar housing members spaced apart to accommodate the passage of a particle beam through the structure between the members. Each of the housing members have a plurality of serially aligned hollows defined therein, and also passages, formed in the members, which interconnect serially adjacent hollows to provide communication between the hollows. The opposing planar housing members are spaced and aligned such that the hollows in one member cooperate with corresponding hollows in the other member to form a plurality of resonant cavities aligned along the particle beam within the cavity structure. To facilitate the obtaining of a constant field gradient within the cavity structure, the passages are configured so as to be incrementally narrower in the direction of travel of the particle beam. In addition, the spacing distance between the opposing housing members is configured to be incrementally smaller in the direction of travel of the beam.

  12. Constant field gradient planar coupled cavity structure

    DOEpatents

    Kang, Yoon W.; Kustom, Robert L.

    1999-01-01

    A cavity structure having at least two opposing planar housing members spaced apart to accommodate the passage of a particle beam through the structure between the members. Each of the housing members have a plurality of serially aligned hollows defined therein, and also passages, formed in the members, which interconnect serially adjacent hollows to provide communication between the hollows. The opposing planar housing members are spaced and aligned such that the hollows in one member cooperate with corresponding hollows in the other member to form a plurality of resonant cavities aligned along the particle beam within the cavity structure. To facilitate the obtaining of a constant field gradient within the cavity structure, the passages are configured so as to be incrementally narrower in the direction of travel of the particle beam. In addition, the spacing distance between the opposing housing members is configured to be incrementally smaller in the direction of travel of the beam.

  13. Constant field gradient planar coupled cavity structure

    DOEpatents

    Kang, Y.W.; Kustom, R.L.

    1999-07-27

    A cavity structure is disclosed having at least two opposing planar housing members spaced apart to accommodate the passage of a particle beam through the structure between the members. Each of the housing members have a plurality of serially aligned hollows defined therein, and also passages, formed in the members, which interconnect serially adjacent hollows to provide communication between the hollows. The opposing planar housing members are spaced and aligned such that the hollows in one member cooperate with corresponding hollows in the other member to form a plurality of resonant cavities aligned along the particle beam within the cavity structure. To facilitate the obtaining of a constant field gradient within the cavity structure, the passages are configured so as to be incrementally narrower in the direction of travel of the particle beam. In addition, the spacing distance between the opposing housing members is configured to be incrementally smaller in the direction of travel of the beam. 16 figs.

  14. Stable planar mesoscopic photonic crystal cavities.

    PubMed

    Magno, G; Monmayrant, A; Grande, M; Lozes-Dupuy, F; Gauthier-Lafaye, O; Calò, G; Petruzzelli, V

    2014-07-15

    Mesoscopic self-collimation (MSC) in mesoscopic photonic crystals with high reflectivity is exploited to realize a novel high Q-factor cavity by means of mesoscopic PhC planar mirrors. These mirrors efficiently confine a mode inside a planar Fabry-Perot-like cavity, that results from a beam focusing effect that stabilizes the cavity even for small beam sizes, resembling the focusing behavior of curved mirrors. Moreover, they show an improved reflectivity with respect to their standard distributed Bragg reflector counterparts that allows higher compactness. A Q-factor higher than 10⁴ has been achieved for an optimized 5-period-long mirror cavity. The optimization of the Q-factor and the performances in terms of energy storage, field enhancement, and confinement are detailed. PMID:25121692

  15. Bone scan appearances following bone and bone marrow biopsy

    SciTech Connect

    McKillop, J.H.; Maharaj, D.; Boyce, B.F.; Fogelman, I.

    1984-01-01

    Bone marrow and bone biopsies are performed not infrequently in patients referred for bone scans and represent a potential cause of a ''false positive'' focal abnormality on the bone scan. The authors have therefore examined the scan appearances in a series of patients who had undergone either sternal marrow biopsy, (Salah needle, diameter 1.2 mm) trephine iliac crest marrow biopsy (Jamshidi 11 gauge needle, diameter 3.5 mm) or a transiliac bone biopsy (needle diameter 8 mm). Of 18 patients studied 1 to 45 days after sternal marrow 17 had normal scan appearances at the biopsy site and 1 had a possible abnormality. None of 9 patients studied 4 to 19 days after trephine iliac crest marrow biopsy had a hot spot at the biopsy site. A focal scan abnormality was present at the biopsy site in 9/11 patients studied 5 to 59 days after a trans iliac bone biopsy. No resultant scan abnormality was seen in 4 patients imaged within 3 days of the bone biopsy or in 3 patients imaged 79 to 138 days after the procedure. Bone marrow biopsy of the sternum or iliac crest does not usually cause bone scan abnormalities. A focal abnormality at the biopsy site is common in patients imaged 5 days to 2 months after bone biopsy. The gauge of the needle employed in the biopsy and thus the degree of bone trauma inflicted, is likely to be main factor determining the appearance of bone scan abnormalities at the biopsy site.

  16. Planar graphical models which are easy

    SciTech Connect

    Chertkov, Michael; Chernyak, Vladimir

    2009-01-01

    We describe a rich family of binary variables statistical mechanics models on planar graphs which are equivalent to Gaussian Grassmann Graphical models (free fermions). Calculation of partition function (weighted counting) in the models is easy (of polynomial complexity) as reduced to evaluation of determinants of matrixes linear in the number of variables. In particular, this family of models covers Holographic Algorithms of Valiant and extends on the Gauge Transformations discussed in our previous works.

  17. Planar Poincare Charts For Polarization Calculations

    NASA Technical Reports Server (NTRS)

    Tedjojuwono, Ken K.; Hunter, William W.; Ocheltree, Stewart L.

    1993-01-01

    New type of stereographic projection of Poincare sphere makes flat charts for use in graphical analyses of polarization-transformation characteristics of optical components or systems. Charts used to predict polarization state at output of birefringent material for any arbitrary input polarization state. Analyses of some polarization-dependent optical components or systems reduced to simple graphical procedures. Planar charts more practical to use and store.

  18. Experiments in Planar Multipole Ion Traps

    NASA Astrophysics Data System (ADS)

    Clark, Rob; Burke, Timothy; Green, Dylan

    2016-05-01

    We present the design and demonstration of multipole ion traps based on concentric rings. We have developed both surface-electrode and layered planar trap designs which enable one to null the quadratic term in the electric potential to a high degree. Experiments demonstrating frequency upconversion of an applied signal demonstrate the nonlinear dynamics present in the trap. Applications include quantum chaos, ultracold chemistry, and, potentially, mass spectrometry. We acknowledge support from the Research Corporation for Science Advancement and from The Citadel Foundation.

  19. Circular dichroism of planar chiral magnetic metamaterials.

    PubMed

    Decker, M; Klein, M W; Wegener, M; Linden, S

    2007-04-01

    We propose, fabricate, and study a double-layer chiral planar metamaterial that exhibits pronounced circular dichroism at near-infrared wavelengths. The antisymmetric oscillation modes of the two coupled layers allow local magnetic-dipole moments and enhanced polarization effects compared with similar single-layer systems where only electric-dipole moments occur. Experiment and rigorous theoretical calculations are in good agreement. PMID:17339960

  20. The Role of 99mTc-Annexin V Apoptosis Scintigraphy in Visualizing Early Stage Glucocorticoid-Induced Femoral Head Osteonecrosis in the Rabbit

    PubMed Central

    Wang, Xiaolong; Liu, Yu; Wang, Xuemei; Liu, Rui; Li, Jianbo; Zhang, Guoliang; Li, Qiang; Wang, Lei; Bai, Zhigang; Zhao, Jianmin

    2016-01-01

    Objective. To validate the ability of 99mTc-Annexin V to visualize early stage of glucocorticoid-induced femoral head necrosis by comparing with 99mTc-MDP bone scanning. Methods. Femoral head necrosis was induced in adult New Zealand white rabbits by intramuscular injection of methylprednisolone. 99mTc-Annexin scintigraphy and 99mTc-MDP scans were performed before and 5, 6, and 8 weeks after methylprednisolone administration. Rabbits were sacrificed at various time points and conducted for TUNEL and H&E staining. Results. All methylprednisolone treated animals developed femoral head necrosis; at 8 weeks postinjection, destruction of bone structure was evident in H&E staining, and apoptosis was confirmed by the TUNEL assay. This was matched by 99mTc-Annexin V images, which showed a significant increase in signal over baseline. Serial 99mTc-Annexin V scans revealed that increased 99mTc-Annexin V uptake could be observed in 5 weeks. In contrast, there was no effect on 99mTc-MDP signal until 8 weeks. The TUNEL assay revealed that bone cell apoptosis occurred at 5 weeks. Conclusion. 99mTc-Annexin V is superior to 99mTc-MDP for the early detection of glucocorticoid-induced femoral head necrosis in the rabbit and may be a better strategy for the early detection of glucocorticoid-induced femoral head necrosis in patients. PMID:26989689

  1. Recirculating Planar Magnetron Modeling and Experiments

    NASA Astrophysics Data System (ADS)

    Franzi, Matthew; Gilgenbach, Ronald; Hoff, Brad; French, Dave; Lau, Y. Y.

    2011-10-01

    We present simulations and initial experimental results of a new class of crossed field device: Recirculating Planar Magnetrons (RPM). Two geometries of RPM are being explored: 1) Dual planar-magnetrons connected by a recirculating section with axial magnetic field and transverse electric field, and 2) Planar cathode and anode-cavity rings with radial magnetic field and axial electric field. These RPMs have numerous advantages for high power microwave generation by virtue of larger area cathodes and anodes. The axial B-field RPM can be configured in either the conventional or inverted (faster startup) configuration. Two and three-dimensional EM PIC simulations show rapid electron spoke formation and microwave oscillation in pi-mode. Smoothbore prototype axial-B RPM experiments are underway using the MELBA accelerator at parameters of -300 kV, 1-20 kA and pulselengths of 0.5-1 microsecond. Implementation and operation of the first RPM slow wave structure, operating at 1GHz, will be discussed. Research supported by AFOSR, AFRL, L-3 Communications, and Northrop Grumman. Done...processed 1830 records...17:52:57 Beginning APS data extraction...17:52:57

  2. Planar geometry inertial electrostatic confinement fusion device

    NASA Astrophysics Data System (ADS)

    Knapp, Daniel R.

    2015-03-01

    In the classic gridded inertial electrostatic confinement (IEC) fusion reactor, ion bombardment of the grid leads to heating, thermionic electron emission, significant power loss, and ultimately melting of the grid. Gridless IEC devices have sought to overcome these limitations. Klein reported a gridless device in which ions are circulated as a linear beam in an electrostatic analogue of an optical resonator. To overcome limits of stored ions due to space charge effects at the turning regions, the device employed multiple overlapping traps. The work reported here seeks to further increase the turning region space in a gridless trap by employing a planar geometry. Ion trapping in the planar device was examined by simulating trajectories of 2H+ ions with SIMION 8.1 software. Simulations were carried out using multiple potentials as in Klein's device and for a single potential trap as a planar analogue of the anharmonic ion trap. Scattering by background gas was simulated using a hard sphere collision model, and the results suggested the device will require operation at low pressure with a separate ion source.

  3. Fast planar segmentation of depth images

    NASA Astrophysics Data System (ADS)

    Javan Hemmat, Hani; Pourtaherian, Arash; Bondarev, Egor; de With, Peter H. N.

    2015-03-01

    One of the major challenges for applications dealing with the 3D concept is the real-time execution of the algorithms. Besides this, for the indoor environments, perceiving the geometry of surrounding structures plays a prominent role in terms of application performance. Since indoor structures mainly consist of planar surfaces, fast and accurate detection of such features has a crucial impact on quality and functionality of the 3D applications, e.g. decreasing model size (decimation), enhancing localization, mapping, and semantic reconstruction. The available planar-segmentation algorithms are mostly developed using surface normals and/or curvatures. Therefore, they are computationally expensive and challenging for real-time performance. In this paper, we introduce a fast planar-segmentation method for depth images avoiding surface normal calculations. Firstly, the proposed method searches for 3D edges in a depth image and finds the lines between identified edges. Secondly, it merges all the points on each pair of intersecting lines into a plane. Finally, various enhancements (e.g. filtering) are applied to improve the segmentation quality. The proposed algorithm is capable of handling VGA-resolution depth images at a 6 FPS frame-rate with a single-thread implementation. Furthermore, due to the multi-threaded design of the algorithm, we achieve a factor of 10 speedup by deploying a GPU implementation.

  4. Planar Tunneling Spectroscopy of Graphene Nanodevices

    NASA Astrophysics Data System (ADS)

    Wang, Joel I.-Jan; Bretheau, Landry; Pisoni, Riccardo; Watanabe, Kenji; Taniguchi, Takashi; Jarillo-Herrero, Pablo

    2-D Van-der-Waals mesoscopic physics have seen a rapid development in the last 10 years, with new materials each year added to the toolbox. Stacking them like Lego enables the combination of their individual electronic properties. In particular, hexagonal boron nitride, which is an insulator, gives the possibility to perform planar (2-D to 2-D) tunneling spectroscopy within this type of heterostructures. Unlike standard transport measurements, tunneling spectroscopy enables to probe the electronic properties in the energy domain. Moreover, since planar tunneling probes a large area of the system, global quantum features such as quantum Hall effect, superconducting proximity effect or quantum confinement can be investigated. In this talk, we will present implementation of heterostructures consisting of graphene, hexagonal boron nitride, and graphite, fabricated for planar tunneling spectroscopy. In order to reveal the intrinsic properties of materials, the fabrication scheme aims at preserving the pristine nature of the 2-DEGS as well as minimizing the doping introduced by external probes. As a demonstration, measurements of these devices in normal states, high magnetic field environment, and induced superconducting state will be presented.

  5. Spontaneous Planar Chiral Symmetry Breaking in Cells

    NASA Astrophysics Data System (ADS)

    Hadidjojo, Jeremy; Lubensky, David

    Recent progress in animal development has highlighted the central role played by planar cell polarity (PCP) in epithelial tissue morphogenesis. Through PCP, cells have the ability to collectively polarize in the plane of the epithelium by localizing morphogenetic proteins along a certain axis. This allows direction-dependent modulation of tissue mechanical properties that can translate into the formation of complex, non-rotationally invariant shapes. Recent experimental observations[1] show that cells, in addition to being planar-polarized, can also spontaneously develop planar chirality, perhaps in the effort of making yet more complex shapes that are reflection non-invariant. In this talk we will present our work in characterizing general mechanisms that can lead to spontaneous chiral symmetry breaking in cells. We decompose interfacial concentration of polarity proteins in a hexagonal cell packing into irreducible representations. We find that in the case of polar concentration distributions, a chiral state can only be reached from a secondary instability after the cells are polarized. However in the case of nematic distributions, we show that a finite-amplitude (subcritical, or ``first-order'') nematic transition can send the system from disorder directly to a chiral state. In addition, we find that perturbing the system by stretching the hexagonal packing enables direct (supercritical, or ``second-order'') chiral transition in the nematic case. Finally, we do a Landau expansion to study competition between stretch-induced chirality and the tendency towards a non-chiral state in packings that have retained the full 6-fold symmetry.

  6. Non-planar on-shell diagrams

    NASA Astrophysics Data System (ADS)

    Franco, Sebastián; Galloni, Daniele; Penante, Brenda; Wen, Congkao

    2015-06-01

    We initiate a systematic study of non-planar on-shell diagrams in SYM and develop powerful technology for doing so. We introduce canonical variables generalizing face variables, which make the d log form of the on-shell form explicit. We make significant progress towards a general classification of arbitrary on-shell diagrams by means of two classes of combinatorial objects: generalized matching and matroid polytopes. We propose a boundary measurement that connects general on-shell diagrams to the Grassmannian. Our proposal exhibits two important and non-trivial properties: positivity in the planar case and it matches the combinatorial description of the diagrams in terms of generalized matroid polytopes. Interestingly, non-planar diagrams exhibit novel phenomena, such as the emergence of constraints on Plücker coordinates beyond Plücker relations when deleting edges, which are neatly captured by the generalized matching and matroid polytopes. This behavior is tied to the existence of a new type of poles in the on-shell form at which combinations of Plücker coordinates vanish. Finally, we introduce a prescription, applicable beyond the MHV case, for writing the on-shell form as a function of minors directly from the graph.

  7. Facts about Broken Bones

    MedlinePlus

    ... las fracturas de huesos Your bones are tough stuff — but even tough stuff can break. Like a wooden pencil, bones will ... that? Get a lot of physical activity, especially stuff like jumping and running. Feed your bones the ...

  8. Bone marrow aspiration

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003658.htm Bone marrow aspiration To use the sharing features on this page, please enable JavaScript. Bone marrow is the soft tissue inside bones that helps ...

  9. Bone density scan (image)

    MedlinePlus

    ... bone the higher the risk of fractures. A bone scan, along with a patient's medical history, is a ... and whether any preventative treatment is needed. A bone density scan has the advantage of being painless and exposing ...

  10. Smoking and Bone Health

    MedlinePlus

    ... direct relationship between tobacco use and decreased bone density. Analyzing the impact of cigarette smoking on bone ... hard to determine whether a decrease in bone density is due to smoking itself or to other ...

  11. Menopause and Bone Loss

    MedlinePlus

    ... You reach your highest bone mass (size and density) at about age 30. Then, sometime between age ... your bones, your doctor may do a bone density test (DEXA scan). This test gives exact measurements ...

  12. [Evaluation of bone sterngth].

    PubMed

    Mashiba, Tasuku

    2016-01-01

    Biomechanical testing of the bone provides the most important and direct information about bone strength. This article explains biomechanical priciples including structural mechanical properties and intrinsic material properties, and serves actual biomechanical testing tedhniques for bone specimens. PMID:26728529

  13. Bone marrow biopsy

    MedlinePlus

    Biopsy - bone marrow ... A bone marrow biopsy may be done in the health care provider's office or in a hospital. The sample may be taken from the pelvic or breast bone. Sometimes, other areas are used. Marrow is removed ...

  14. Spin-on-dielectrics: Planarity modeling

    NASA Astrophysics Data System (ADS)

    Smythe, John A.

    2009-12-01

    The idea of replacing chemical vapor deposition (CVD), plasma enhanced chemical vapor deposition (PECVD), and sputter oxide materials, among others, with a spin-on approach has been of interest in the Semiconductor industry for the last two decades. The technique draws from the planarizing nature of a liquid when applied to surface topography. The method, initially known as Spin-On-Glass (SOG), has more recently taken on the more general term Spin-On-Dielectric (SOD). Prior works have addressed issues including, crack resistance, etch rate, resistance to photo resist stripping conditions, film stress, defectivity and planarity. Planarity characteristics have not been addressed with the rigor needed to predict the interaction between variable topography in terms of the degree of local and global planarization. In this work, experimental results for film thickness as a function of viscosity and spin speed are presented. Experimental results for percent trench fill are presented for different trench depth, width and coating thickness. Models have been developed using level-set two-phase flow and Arbitrary Lagrangian-Eulerian (ALE) interface tracking methods as implemented in COMSOL(TM) to describe the movement of an initial interface in time. Droplet spreading and capillary rise cases were used to validate the level-set two-phase flow application mode treatment of variable viscosity, surface tension and contact angle. This work presents model results for film thinning on 200 mm wafer and local planarization characteristics at the nanometer scale of present day semiconductor device features. The film thinning model is based on a set of equations derived to represent flow, evaporation and diffusion for variable rotational velocity, solvent concentration and initial profile. Model results for full wafer thinning include the effects of variable evaporation with radius on final film height profile given differing initial profiles. A simple and a complex evaporation

  15. Preliminary results of automated removal of degenerative joint disease in bone scan lesion segmentation

    NASA Astrophysics Data System (ADS)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Auerbach, Martin; Goldin, Jonathan; Henkel, Keith; Banola, Ashley; Morris, Darren; Coy, Heidi; Brown, Matthew S.

    2013-03-01

    Whole-body bone scintigraphy (or bone scan) is a highly sensitive method for visualizing bone metastases and is the accepted standard imaging modality for detection of metastases and assessment of treatment outcomes. The development of a quantitative biomarker using computer-aided detection on bone scans for treatment response assessment may have a significant impact on the evaluation of novel oncologic drugs directed at bone metastases. One of the challenges to lesion segmentation on bone scans is the non-specificity of the radiotracer, manifesting as high activity related to non-malignant processes like degenerative joint disease, sinuses, kidneys, thyroid and bladder. In this paper, we developed an automated bone scan lesion segmentation method that implements intensity normalization, a two-threshold model, and automated detection and removal of areas consistent with non-malignant processes from the segmentation. The two-threshold model serves to account for outlier bone scans with elevated and diffuse intensity distributions. Parameters to remove degenerative joint disease were trained using a multi-start Nelder-Mead simplex optimization scheme. The segmentation reference standard was constructed manually by a panel of physicians. We compared the performance of the proposed method against a previously published method. The results of a two-fold cross validation show that the overlap ratio improved in 67.0% of scans, with an average improvement of 5.1% points.

  16. Radionuclide Treatment with 153Sm-EDTMP is Effective for the Palliation of Bone Pain in the Context of Extensive Bone Marrow Metastases: A Case Report

    PubMed Central

    Kairemo, Kalevi; Rasulova, Nigora; Suslaviciute, Justina; Alanko, Tuomo

    2014-01-01

    Radionuclide therapy is widely used as an effective modality in the management of bone pain. The main indication for this treatment is symptomatic bone metastases, confirmed by bone scintigraphy. We present a case of small cell lung cancer (SCLC) stage T4N2M1b, with a good metabolic response to systemic therapy and radiotherapy of the primary tumor and locoregional disease, which became metabolically less active and remarkably smaller in size (reduction to 1/6 of the original volume). In spite of the good overall response, the patient developed a syndrome with severe bone pain and had progression in the bone marrow metastases, confirmed by 18F-FDG PET/CT. The patient received 153Sm-EDTMP treatment with a good clinical response. However, in the whole body bone scan with the therapeutic dose, there was no visual evidence of bone metastasis. Retrospectively, by drawing the region of interest, it was possible to identify one metastatic site. The possible mechanisms of the efficacy of this treatment modality, in this specific setting, are also discussed. PMID:27408870

  17. Bone marrow transplant - discharge

    MedlinePlus

    Transplant - bone marrow - discharge; Stem cell transplant - discharge; Hematopoietic stem cell transplant - discharge; Reduced intensity; Non-myeloablative transplant - discharge; Mini transplant - discharge; Allogenic bone marrow transplant - ...

  18. Significance of 99mTc-Sestamibi myocardial scintigraphy after percutaneous coronary intervention in patients with acute myocardial infarction

    PubMed Central

    Akashi, Yoshihiro J.; Ashikaga, Kohei; Takano, Makoto; Izumo, Masaki; Ishibashi, Yuki; Kida, Keisuke; Yoneyama, Kihei; Suzuki, Kengo; Miyake, Fumihiko; Banach, Maciej

    2011-01-01

    Summary Background This study was designed to clarify the significance of washout rate (WR) determined from 99mTc-sestamibi myocardial scintigraphic images and the levels of cardiac enzymes in patients with acute myocardial infarction (AMI) after percutaneous coronary intervention (PCI). Material/Methods A total of 56 consecutive patients with AMI (mean age 65.8±8.5 years), who underwent PCI on admission, were included. Cardiac enzyme, the MB isoenzyme of creatinine kinase (CK-MB), was measured every 3 h after admission. Two weeks after the onset of AMI, 99mTc-sestamibi myocardial scintigraphy was performed at early (30 min) and delayed (4 h) phases after tracer injection. The heart-to-mediastinum ratio (H/M) and WR were calculated from the planar images. Results PCI was performed at 9.4±6.0 h after the onset of AMI. In 26 patients the culprit lesion was located in the right coronary artery and in 24 patients it was located in the left anterior descending coronary artery. The peak CK-MB was 274.1±169.4 IU/L (13.5±3.9 h). The early and delayed H/Ms and WR of 99mTc-sestamibi were 2.74±0.58, 3.00±0.70, and 58.8±10.0%, respectively. The delayed H/M was significantly correlated with the peak CK-MB (r=−0.37, p=0.005). The WR of 99mTc-sestamibi was also significantly correlated with the peak CK-MB (r=−0.34, p=0.012). Conclusions These results suggest that the WR determined from 99mTc-sestamibi myocardial scintigraphic images reflects the extent of myocardial damage in AMI patients. PMID:21358600

  19. Planar cell polarity aligns osteoblast division in response to substrate strain.

    PubMed

    Galea, Gabriel L; Meakin, Lee B; Savery, Dawn; Taipaleenmaki, Hanna; Delisser, Peter; Stein, Gary S; Copp, Andrew J; van Wijnen, Andre J; Lanyon, Lance E; Price, Joanna S

    2015-03-01

    Exposure of bone to dynamic strain increases the rate of division of osteoblasts and also influences the directional organization of the cellular and molecular structure of the bone tissue that they produce. Here, we report that brief exposure to dynamic substrate strain (sufficient to rapidly stimulate cell division) influences the orientation of osteoblastic cell division. The initial proliferative response to strain involves canonical Wnt signaling and can be blocked by sclerostin. However, the strain-related orientation of cell division is independently influenced through the noncanonical Wnt/planar cell polarity (PCP) pathway. Blockade of Rho-associated coiled kinase (ROCK), a component of the PCP pathway, prevents strain-related orientation of division in osteoblast-like Saos-2 cells. Heterozygous loop-tail mutation of the core PCP component van Gogh-like 2 (Vangl2) in mouse osteoblasts impairs the orientation of division in response to strain. Examination of bones from Vangl2 loop-tail heterozygous mice by µCT and scanning electron microscopy reveals altered bone architecture and disorganized bone-forming surfaces. Hence, in addition to the well-accepted role of PCP involvement in response to developmental cues during skeletal morphogenesis, our data reveal that this pathway also acts postnatally, in parallel with canonical Wnt signaling, to transduce biomechanical cues into skeletal adaptive responses. The simultaneous and independent actions of these two pathways appear to influence both the rate and orientation of osteoblast division, thus fine-tuning bone architecture to meet the structural demands of functional loading. PMID:25264362

  20. Vesicoureteral Reflux Detected with 99mTc-DTPA Renal Scintigraphy during Evaluation of Renal Function

    PubMed Central

    Manevska, Nevena; Stojanoski, Sinisa; Majstorov, Venjamin; Pop-Gjorcheva, Daniela; Zdraveska, Nikolina; Kuzmanovska, Dafina

    2016-01-01

    BACKGROUND: Radionuclide techniques, as direct radionuclide cystography and 99mTc-DMSA scintigraphy, have been used in evaluation of vesicoureteral reflux (VUR) and reflux nephropathy (RN) in children. Dynamic 99mTc-DTPA scintigraphy is reserved for evaluation of differential renal function and obstruction in children, where hydronephrosis is detected by ultrasonography (US) pre- or postnatally. CASE REPORT: Six year old boy was prenatally diagnosed with bilateral hydronephrosis. Postnatal, severe bilateral VUR was detected by voiding urethrocytography. US and 99mTc-DTPA scintigraphy performed in the first month of life showed small left kidney that participated with 2% in the global renal function. Bilateral cutaneous ureterostomy has been performed in order to obtain good renal drainage and promote optimal renal growth. Twelve months later, classic antireflux procedure was done. Control 99mTc-DTPA scintigraphy, 5 ys after antireflux surgery, revealed persisting radioactivity during the diuretic phase, in the left kidney that indicated antireflux procedure failure with VUR reappearance. CONCLUSION: 99mTc-DTPA scintigraphy is the first method of choice for long-term monitoring of individual kidney function in children with VUR and other congenital urinary tract anomalies. Additionally, it can be used as indirect radionuclide cystography when rising of radioactivity in the kidney region, during the diuretic phase can indicate presence of VUR. PMID:27275347

  1. Technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy in the differential diagnosis of cerebral abscesses.

    PubMed

    Spinelli, F; Sara, R; Milella, M; Ruffini, L; Sterzi, R; Causarano, I R; Sberna, M

    2000-01-01

    The diagnosis of brain abscess is often difficult, as the clinical symptoms are not specific. Computed tomography (CT) and magnetic resonance imaging (MRI) are highly sensitive, but different cerebral lesions, especially neoplasms, can have the same ring-like contrast enhancement. Brain abscess is a severe illness requiring rapid diagnosis to choose the most appropriate therapy. Technetium-99m hexamethylpropylene amine oxime (HMPAO)-labelled leucocyte scintigraphy is commonly used to detect an inflammatory process. The aim of this study was to present the results obtained with leucocyte scintigraphy in 65 patients with intracranial mass lesions and clinical findings compatible to or suggestive of brain abscess. The final diagnosis, based on surgery, clinical findings and stereotatic puncture, was brain abscess in 17 patients, primary brain neoplasm in 22, brain metastasis in 16, lymphoma in 2, cysticercosis in 2, hematoma in 2 and cerebral infarction in 4. 99mTc-HMPAO leucocyte scintigraphy was positive in all abscess cases. The scan was negative in the rest of the patients examined, with the exception of one lesion, which was finally diagnosed as a tumour (1 false-positive). All patients who did not have false-negative scans were treated with steroids. The sensitivity, specificity and diagnostic accuracy of leucocyte scintigraphy was 100%, 97.8% and 98.4%, respectively. In conclusion, in our experience, leucocyte scintigraphy is a valuable aid in the differential diagnosis between abscess and neoplasm. PMID:10654146

  2. Diagnosis of pyogenic pelvic inflammatory diseases by 99mTc-HMPAO leucocyte scintigraphy.

    PubMed

    Rachinsky, I; Boguslavsky, L; Goldstein, D; Golan, H; Pak, I; Katz, M; Lantsberg, S

    2000-12-01

    Pelvic inflammatory disease (PID) is one of the major health problems of women of child-bearing age. Among the most serious complications of PID is the formation of a tubo-ovarian abscess (TOA). Early diagnosis of this condition may prevent serious surgical complications such as peritonitis and sepsis, which may be fatal. The purpose of this study was to investigate the efficacy of technetium-99m hexamethylpropylene amine oxime (HMPAO) leucocyte scintigraphy in the diagnosis of TOA. Twenty women with high clinical suspicion of TOA underwent 99mTc-HMPAO leucocyte scintigraphy. The labelling of leucocytes with 99mTc-HMPAO was performed according to a standard protocol. Scans were obtained at 1, 3 and 24 h following the injection of the labelled leucocytes. In eight cases the early and/or late scan was positive, in 11 cases it was negative, and in one case of ovarian cyst torsion, confirmed by laparoscopy, it showed slight uptake in the capsule of the cyst (false-positive). The sensitivity of 99mTc-HMPAO leucocyte scintigraphy was 100%, specificity 91.6%, positive predictive value 89%, negative predictive value 100% and overall accuracy 95%. It is concluded that leucocyte scintigraphy is a non-invasive, safe, physiological and accurate procedure for the diagnosis of TOA. The 24-h scan is crucial, since in some cases the abscess was not clearly visualized on the early scan. Leucocyte scintigraphy may reduce the need for CT, diagnostic laparoscopy and unnecessary invasive surgical procedures. PMID:11189939

  3. Thallium scintigraphy during dobutamine infusion: nonexercise-dependent screening test for coronary disease

    SciTech Connect

    Mason, J.R.; Palac, R.T.; Freeman, M.L.; Virupannavar, S.; Loeb, H.S.; Kaplan, E.; Gunnar, R.M.

    1984-03-01

    Exercise thallium scintigraphy has proven to be a sensitive method for detecting coronary artery disease (CAD). However, early redistribution of thallium and inadequate exercise can reduce its sensitivity. In this study, dobutamine was infused in incremental doses (5, 10, 15, and 20 micrograms/kg/min) in 24 patients being evaluated for chest pain. Thallium scintigraphy was completed during the maximum dose of dobutamine tolerated and repeated 4 hours later. Significant CAD was present in 16 patients; the remaining eight had normal coronaries. Exercise ECG was obtained in 23 patients. During dobutamine thallium scintigraphy, reversible perfusion defects occurred in 15 of 16 CAD and in one of eight non-CAD patients, resulting in a sensitivity of 94% and a specificity of 87%. Exercise ECG had a sensitivity of 60% and a specificity of 63%. We conclude that: (1) dobutamine thallium scintigraphy appears to be a sensitive method for detecting significant CAD and provided a more sensitive screening test than exercise ECG; (2) dobutamine thallium scintigraphy is especially useful in patients who cannot exercise; and (3) because imaging occurs during dobutamine infusion, the problem of early redistribution may be mitigated.

  4. Quantitative hepatobiliary scintigraphy in normal cats and in cats with experimental cholangiohepatitis.

    PubMed

    Newell, S M; Graham, J P; Roberts, G D; Ginn, P E; Greiner, E C; Cardwell, A; Mauragis, D; Knutsen, C; Harrison, J M; Martin, F G

    2001-01-01

    Quantitative hepatobiliary scintigraphy using 99mTc-mebrofenin was performed on eight normal cats and on the same cats after induction of experimental cholangiohepatitis by infection with the liver fluke Platynosomum concinnum. Hepatobiliary scintigraphy was performed 3 times at 10 weeks, 4 months and 6 months after infection. In addition, routine biochemical tests, hepatic ultrasound and ultrasound guided hepatic biopsy samples were obtained at the same time points, and the results compared with hepatobiliary scintigraphy. The normal hepatic extraction fraction was determined to be 85%, and the normal hepatic excretion half time (T 1/2) was 14 minutes. There was no significant change in scintigraphic parameters compared to pre-infection values at any time following infection with the liver fluke. No correlation between scintigraphic parameters and histologic scores was found; however, significant correlation was identified between parasite burden and histologic scores 6 months following infection. Despite the presence of severe multifocal histologic abnormalities, minimal clinical, biochemical and scintigraphic derangements were identified using this model of cholangiohepatitis. Based on this study, hepatobiliary scintigraphy appears to be an insensitive test for structural hepatobiliary abnormalities. The role of hepatobiliary scintigraphy in functional hepatobiliary abnormalities of the feline liver has not been determined. PMID:11245241

  5. Bone demineralization

    NASA Technical Reports Server (NTRS)

    Mack, P. B.; Vose, G. P.; Vogt, F. B.; Lachance, P. A.

    1971-01-01

    Crew members of the Gemini 4, Gemini 5, and Gemini 7 missions were compared regarding skeletal changes in three major anatomic sites with respect to changes in skeletal density during space flight. Bone-mass changes have been found for the command pilot and the pilot of each mission in the conventional os calcis section, in the combined sections covering 60 percent of the os calcis, and in hand phalanges 5-2 and 4-2. Comparison of radiographically determined losses in X-ray absorbence with X-ray absorbence losses in healthy young men subjected to bedrest immobilization for the same length of time showed that losses for the crewmembers exceeded losses for the bedrest subjects in all cases; this was an indication that restriction of body movement did not represent the only factor involved.

  6. Dexamethasone-suppression adrenal scintigraphy in hyperandrogenism: concise communication

    SciTech Connect

    Gross, M.D.; Freitas, J.E.; Swanson, D.P.; Woodbury, M.C.; Schteingart, D.E.; Beierwaltes, W.H.

    1981-01-01

    To assess the contribution of adrenal-derived androgens in women with hirsutism, adrenal scintigrams under dexamethasone suppression (DS) were performed on 35 women with increasing facial or body hair and irregular or absent menses. Based upon the DS regimen chosen (8 mg/d for 2 days or 4 md/d for 7 days before the injection of 6..beta..-(/sup 131/I)iodomethylnorcholesterol), three imaging patterns were identified. The first was the absence of uptake before 3 days (8-mg DS) or before 5 days (4-mg DS) after injection. This imaging pattern was seen in 17 of the 35 patients studied and was considered normal. The second pattern was bilateral uptake earlier than 3 days (8-mg DS regimen) or 5 days (4-mg DS) after injection. This was seen in 13 of the 35 patients and was interpreted as bilateral early visualization. Adrenal-vein catheterization performed on six patients with this pattern showed increased adrenal-vein testosterone. The third pattern, observed in five patients, was unilateral early visualization, which in four cases investigated to date was the result of an adrenocortical adenoma. This study confirms the adrenal cortex as a source of androgens in women with hirsutism and hyperandrogenism and demonstrates that DS adrenal scintigraphy can be utilized to identify those women in whom adrenal-derived androgens contribute to their hyperandrogenism.

  7. Hepatobiliary scintigraphy in the evaluation of feline liver disease.

    PubMed

    Newell, S M; Selcer, B A; Roberts, R E; Cornelius, L M; Mahaffey, E A

    1996-01-01

    Hepatobiliary scintigraphy (HBS) was performed in 10 cats with histologically documented hepatobiliary disease. The scintigraphic patterns were classified into one of 5 categories: normal, primary hepatocellular dysfunction, primary intrahepatic cholestasis, mixed hepatocellular and intrahepatic cholestasis, and extrahepatic obstructive patterns. Initial attempts were made to correlate specific disease entities with HBS patterns, but a consistent relationship could not be determined. A correlation between the histological severity of a given hepatic disease and the HBS pattern was made. All cats (n = 5) with a mixed hepatocellular and intrahepatic cholestasis scintigraphic pattern with normal gallbladder function had a histologically severe form of their individual hepatic disease. Three of the 4 cats with an intrahepatic cholestasis pattern and normal hepatocellular and gallbladder function had histologically mild or moderate forms of their individual hepatic diseases. One cat had an extrahepatic obstructive pattern where no radiopharmaceutical was identified in the gallbladder or small intestine by 3 hours postinjection. This study suggests that HBS can be useful in cats with hepatobiliary disease to assess the severity of hepatic dysfunction, and to determine if extrahepatic biliary obstruction is present. Correlation between HBS patterns and specific disease entities such as hepatic lipidosis or cholangitis-cholangiohepatitis syndrome could not be made in this study. PMID:8884717

  8. Myocardial perfusion scintigraphy during maximal coronary artery vasodilation with adenosine

    SciTech Connect

    Verani, M.S.; Mahmarian, J.J. )

    1991-05-21

    Pharmacologic coronary vasodilation as an adjunct to thallium-201 myocardial perfusion scintigraphy provides an important alternative form of stress that has been increasingly used in patients unable to perform an exercise stress test. Although dipyridamole has traditionally been used for this purpose, there are several compelling reasons why adenosine may be a preferable agent. First, dipyridamole acts by blocking the reuptake and transport of adenosine, which is the effective substance responsible for coronary vasodilation. Second, exogenous adenosine has a very short half-life (less than 2 seconds), which explains its very short duration of action as well as the brief, self-limiting duration of its side effects. Third, the adenosine infusion is controllable and may be increased or decreased as desired. Fourth, the coronary vasodilation induced by the doses of adenosine we recommend (140 micrograms/kg/min) may be more profound than that induced by the standard dipyridamole dose. Our experience to date, with nearly 1,000 patients studied, shows the adenosine thallium-201 test to be practical and well tolerated, with high sensitivity (87%) and specificity (94%) for detecting coronary artery disease.

  9. [Detection of open processus vaginalis by radionuclide scintigraphy].

    PubMed

    Jan, T C; Wu, C C; Yang, C C; Lee, Y M

    1992-01-01

    The processus vaginalis usually obliterates spontaneously from the inguinal ring to the scrotum after the descent of testis has been completed. Under certain conditions, it can be reopened. In present reports, 3 cases with open processus vaginalis were described. The first one is a case of uremia due to chronic glomerulonephritis, suddenly suffering from right scrotal and penile swelling, following continuous ambulatory peritoneal dialysis (CAPD) for 4 months. The second one is a case of uremia, due to unknown etiology, suddenly developing right scrotal and penile swelling after 5 months of CAPD. The third one is a case with uremia of uncertain etiology, suffering from bilateral scrotal and penile swelling in the first month of CAPD, following a wrong procedure, by adding some 200cc more dialysate. Three mCi of Tc-99m phytate or pertechnetate, added into the bag of peritoneal dialysate for each patient, allowed us to visualize a peritoneo-vaginal communication. After surgery one of the patients who had been given followup treatment by radionuclide scintigraphy showed no passage of the labeled infusion in the swollen side of the scrotum. A previous postmortem study of adults dying without clinically apparent inguinal hernia demonstrated an open processus vaginalis in 20% of groins examined. Thus, this study suggests that in placement of catheters for CAPD or ventriculo-peritoneal shunt, Tc-99m pertechnetate/phytate may be given through intraperitoneal injection to detect a subclinical open processus vaginalis. PMID:1548740

  10. Exercise, lifestyle, and your bones

    MedlinePlus

    Osteoporosis - exercise; Low bone density - exercise ... Osteoporosis is a disease that causes bones to become brittle and more likely to fracture (break). With osteoporosis, the bones lose density. Bone density is the amount of bone ...

  11. Multiple brown tumors in parathyroid carcinoma mimicking metastatic bone disease.

    PubMed

    Pai, M; Park, C H; Kim, B S; Chung, Y S; Park, H B

    1997-10-01

    An unusual case of multiple brown tumors due to parathyroid carcinoma is reported. The patient presented with lower leg pain. Plain radiographs demonstrated multiple lytic lesions of the lower legs and a Tc-99m MDP bone scan depicted multiple areas of increased uptake suggesting skeletal metastases. Tc-99m sestamibi tumor scintigraphy showed multiple sites of tumor uptake in bones and a large area of increased uptake with a cystic component in the right lower pole of the thyroid gland. An open biopsy from the right tibial lesion revealed a brown tumor. A large parathyroid carcinoma with a necrotic cyst was removed. After parathyroidectomy and right thyroid lobectomy, the patient became free of bone pain and serum PTH levels normalized. A 9-month follow-up Tc-99m MDP bone scan demonstrated less intense uptake in the pelvis, tibia, and fibulae. Nine-month follow-up tumor imaging with Tc-99m MIBI revealed disappearance of the preoperative uptake of multiple brown tumor. PMID:9343725

  12. Sodium 18F-Fluoride PET/CT of Bone, Joint and Other Disorders

    PubMed Central

    Jadvar, Hossein; Desai, Bhushan; Conti, Peter S.

    2014-01-01

    The use of 18F-sodium fluoride (18F-NaF) with positron emission tomography-computed tomography (PET/CT) is increasing. This resurgence of an old tracer has been fueled by several factors including superior diagnostic performance over standard 99mTc-based bone scintigraphy, growth in the availability of PET/CT imaging systems, increase in the number of regional commercial distribution centers for PET radiotracers, the recent concerns about potential chronic shortages with 99mTc based radiotracers, and the recent decision by the Centers for Medicare and Medicaid Services to reimburse for 18F-NaF PET/CT for evaluation of patients with known or suspected bone metastases through the National Oncologic PET Registry. The major goal of this article is to review the current evidence on the diagnostic utility of 18F-NaF in the imaging assessment of bone and joint in a variety of clinical conditions. PMID:25475379

  13. Effect of iron on the biodistribution of bone scanning agents in humans

    SciTech Connect

    Choy, D.; Murray, I.P.C.; Hoschl, R.

    1981-07-01

    Nine patients with chronic iron overload, resulting from either repeated transfusions or hemochromatosis, had bone scans that were characterized by a reduction of bony uptake, marked increase in renal activity, and a significant increase in soft-tissue accumulation of /sup 99m/Tc-labeled bone-seeking agents. These findings were supported by semiquantitative computer analysis. The probable mechanisms of altered biodistribution and the possible role of serum ferritin are discussed. The importance of realizing the effect of excess iron on skeletal scintigraphy is further emphasized by the results of bone scanning in another patient in whom acute iron overload following infusion of iron-dextran resulted in excessive blood pool labeling.

  14. A deep penetrating facial congenital melanocytic tumor with bone involvement and ipsilateral eye blindness.

    PubMed

    Bergman, Reuven; Ben-Arush, Miriam W; Bar-Shalom, Rachel; Gilboa, Michael; Simon, Einav; Hershkovitz, Dov; Sabo, Edmond; Maly, Alexander; Gerami, Pedram; Goldsher, Dorith

    2015-01-01

    Bone involvement has been described in tumors with melanocytic differentiation such as melanotic neuroectodermal tumor of infancy, and very rarely in cellular blue nevi and neurocristic cutaneous hamartoma. We present an unusual case of facial congenital melanocytic tumor that involved the underlying bones and maxillary sinus and led to unilateral blindness. A newborn with a large red bluish patch with peripheral brown and black macules overlying marked swelling on the left side of his face was presented. The tumor was shown by magnetic resonance imaging, scintigraphy, and histopathology to invade the underlying bones and maxillary sinus and to compress the left eyeball resulting in blindness. Histopathology, immunohistochemistry, morphometric computerized microscopy, molecular genetic mutation analysis, and fluorescent in situ hybridization studies were more congruent with a melanocytic nevus. An 8.5-year follow-up was uneventful, with spontaneous partial shrinkage of the tumor. PMID:25222197

  15. High voltage planar multijunction solar cell

    NASA Technical Reports Server (NTRS)

    Evans, J. C., Jr.; Chai, A. T.; Goradia, C. P. (Inventor)

    1982-01-01

    A high voltage multijunction solar cell is provided wherein a plurality of discrete voltage generating regions or unit cells are formed in a single generally planar semiconductor body. The unit cells are comprised of doped regions of opposite conductivity type separated by a gap or undiffused region. Metal contacts connect adjacent cells together in series so that the output voltages of the individual cells are additive. In some embodiments, doped field regions separated by a overlie the unit cells but the cells may be formed in both faces of the wafer.

  16. Planar graphical models which are easy

    NASA Astrophysics Data System (ADS)

    Chernyak, Vladimir Y.; Chertkov, Michael

    2010-11-01

    We describe a rich family of binary variables statistical mechanics models on a given planar graph which are equivalent to Gaussian Grassmann graphical models (free fermions) defined on the same graph. Calculation of the partition function (weighted counting) for such a model is easy (of polynomial complexity) as it is reducible to evaluation of a Pfaffian of a matrix of size equal to twice the number of edges in the graph. In particular, this approach touches upon holographic algorithms of Valiant and utilizes the gauge transformations discussed in our previous works.

  17. The cell biology of planar cell polarity

    PubMed Central

    2014-01-01

    Planar cell polarity (PCP) refers to the coordinated alignment of cell polarity across the tissue plane. Key to the establishment of PCP is asymmetric partitioning of cortical PCP components and intercellular communication to coordinate polarity between neighboring cells. Recent progress has been made toward understanding how protein transport, endocytosis, and intercellular interactions contribute to asymmetric PCP protein localization. Additionally, the functions of gradients and mechanical forces as global cues that bias PCP orientation are beginning to be elucidated. Together, these findings are shedding light on how global cues integrate with local cell interactions to organize cellular polarity at the tissue level. PMID:25349257

  18. Theoretical analysis of planar pulse microwiggler

    SciTech Connect

    Qing-Xiang Liu |; Yong Xu

    1995-12-31

    The Magnetic field distributions of a planar pulse microwiggler are studied analytically and numerically. Exact solutions of two-dimensional magnetic fields are derived, which show that along the electron axis the fields have a variation close enough to a sine wave. We also investigate wiggler field errors due to machining tolerance and effects of the field errors on trajectories of electron with the help numerical simulations. The results are critical for successful operation of CAEP compact free-electron laser experiment under preparation.

  19. Conceptual Design for Superconducting Planar Helical Undulator

    NASA Astrophysics Data System (ADS)

    Sasaki, Shigemi

    2004-05-01

    A preliminary consideration was made on a short-period superconducting planar helical undulator (SCHU) for circularly polarized radiation. The SCHU consists of coils and iron poles/yokes. There is no magnetic structure in the horizontal plane of the electron orbit. The SCHU would provide the large horizontal aperture needed to allow injection into the storage ring. The expected field strength is at least 30% larger than that by an APPLE-type permanent-magnet device with the same gap and the same period.

  20. Walls and chains of planar Skyrmions

    SciTech Connect

    Harland, Derek; Ward, R. S.

    2008-02-15

    In planar (baby) Skyrme systems, there may be extended linear structures which resemble either domain walls or chains of skyrmions, depending on the choice of potential and boundary conditions. We show that systems with a single vacuum, for example, with potential V=1-{phi}{sub 3}, admit chain solutions, whereas walls are ruled out by the uniqueness of the vacuum. On the other hand, in double-vacuum systems such as V=(1/2)(1-{phi}{sub 3}{sup 2}), one has stable wall solutions, but there are no stable chains; the walls may be viewed as the primary objects in such systems, with skyrmions being made out of them.

  1. Optical planar waveguide for cell counting

    PubMed Central

    LeBlanc, John; Mueller, Andrew J.; Prinz, Adrian; Butte, Manish J.

    2012-01-01

    Low cost counting of cells has medical applications in screening, military medicine, disaster medicine, and rural healthcare. In this report, we present a shallow, buried, planar waveguide fabricated by potassium ion exchange in glass that enables low-cost and rapid counting of metal-tagged objects that lie in the evanescent field of the waveguide. Laser light transmitted through the waveguide was attenuated proportionately to the presence of metal-coated microstructures fabricated from photoresist. This technology enables the low-cost enumeration of cells from blood, urine, or other biofluids. PMID:22331960

  2. Vortex gyroscope imaging of planar superfluids.

    PubMed

    Powis, A T; Sammut, S J; Simula, T P

    2014-10-17

    We propose a robust imaging technique that makes it possible to distinguish vortices from antivortices in quasi-two-dimensional Bose-Einstein condensates from a single image of the density of the atoms. Tilting the planar condensate prior to standard absorption imaging excites a generalized gyroscopic mode of the condensate, revealing the sign and location of each vortex. This technique is anticipated to enable experimental measurement of the incompressible kinetic energy spectrum of the condensate and the observation of a negative-temperature phase transition of the vortex gas, driven by two-dimensional superfluid turbulence. PMID:25361263

  3. Broadband Planar 5:1 Impedence Transformer

    NASA Technical Reports Server (NTRS)

    Ehsan, Negar; Hsieh, Wen-Ting; Moseley, Samuel H.; Wollack, Edward J.

    2015-01-01

    This paper presents a broadband Guanella-type planar impedance transformer that transforms so 50 omega to 10 omega with a 10 dB bandwidth of 1-14GHz. The transformer is designed on a flexible 50 micrometer thick polyimide substrate in microstrip and parallel-plate transmission line topologies, and is Inspired by the traditional 4:1 Guanella transformer. Back-to-back transformers were designed and fabricated for characterization in a 50 omega system. Simulated and measured results are in excellent agreement.

  4. Bone scan appearances following biopsy of bone and bone marrow

    SciTech Connect

    McKillop, J.H.; Maharaj, D.; Boyce, B.F.; Fogelman, I.

    1984-10-01

    The influence of sternal marrow aspiration, iliac crest marrow aspiration, and iliac crest bone biopsy on bone scan appearances was examined. Eighteen patients were scanned a mean of 9.9 days after sternal marrow aspiration with a Salah needle. Bone scans obtained in 9 patients a mean of 10 days aftr iliac crest trephine marrow biopsy with a Jamshidi needle showed no abnormality at the biopsy site. In 18 patients with metabolic bone disease who had undergone iliac crest bone biopsy with an 8 mm needle, a scan abnormality due to the biopsy was usually present when the interval between the biopsy and the scan was 5 days to 2 months. Patients who were scanned within 3 days of iliac crest bone biopsy or more than 2 months after biopsy had normal scan appearance at the biopsy site.

  5. Scintigraphy with 99mTc(V)-DMSA in monitoring patients with inflammatory bowel disease.

    PubMed

    Javadi, Hamid; Amiriani, Taghi; Mirkarimi, HoneySadat; Besharat, Sima; Semnani, Shahriar; Abedi, Jamshid; Seyedabadi, Mohammad; Assadi, Majid

    2013-01-01

    The clinical significance of pentavalent technetium-99m dimercaptosuccinic acid (99mTc(V)-DMSA) scintigraphy in diagnosing inflammatory bowel disease (IBD) has not yet been fully elucidated. The aim of this prospective paper was to study the above. This study included 54 patients, 22 females and 32 males (mean age: 36.68±11.49; range: 18-63 years) with IBD who came to our clinics for follow-up and were examined clinically by colonoscopy and 99mTc(V)-DMSA scintigraphy. On the follow-up studies, five patients (9.25%) relapsed, and 49 (90.74%) remained at a steady condition. There was a good correlation between the scintigraphic results and the clinical and colonoscopy data of the patients (P<0.05). In conclusion, our results indicated that 99mTc(V)DMSA scintigraphy can be complementary to colonoscopy for the diagnostic evaluation of IBD. PMID:24251309

  6. Dual thyroid ectopia-role of thyroid scintigraphy and neck ultrasonography

    PubMed Central

    Jain, Tarun Kumar; Meena, Ram Singh; Bhatia, Anmol; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    Ectopic thyroid tissue (ETT) is a rare developmental anomaly of the thyroid tissue where the thyroid gland is not located in its usual position. Dual thyroid ectopia is far rarer. This case of a 5-year-old euthyroid girl with thyroglossal cyst was planned for surgery. Presurgical ultrasonography (USG) of the neck followed by thyroid scintigraphy was performed. There was absent normal thyroid gland with single ETT in neck swelling on USG. However, thyroid scintigraphy revealed two ectopic foci of thyroid tissue; one was corresponding to neck swelling, and other was superior to it at the base of the tongue along with absent eutopic thyroid gland. The repeat neck USG could demonstrate the same. The present case emphasizes that, if the thyroid gland is not visible by USG; ETT should be evaluated with thyroid scintigraphy in case of thyroid dysgenesis. PMID:26430320

  7. 67Gallium citrate scintigraphy to assess metastatic spread in a dog with an oral melanoma.

    PubMed

    Liuti, T; de Vos, J; Bosman, T; van de Wiele, C; Grinwis, G C M; van Bree, H; Peremans, K

    2009-01-01

    Gallium scintigraphy was used to evaluate therapeutic response in a 10-year-old, male, Dutch sheepdog, suffering from an oral melanoma. Treatment was performed with a combination of carboplatin and hypofractionated radiation. Nineteen weeks after radiation therapy, the left submandibular lymph node was surgically removed because of metastatic disease. Thirty weeks after radiation therapy, 67Gallium scintigraphy was performed to assess for residual disease and metastasis. Increased uptake in the right submandibular lymph node area was noted and identified as a melanoma metastasis on cytology. Surgical excision was performed. Twenty-one weeks later, the dog was euthanased because of advanced pulmonary metastases. This report of a case of oral melanoma illustrates the advantages of 67Gallium scintigraphy in monitoring for the presence of metastatic disease and effectiveness of therapy. PMID:19037892

  8. Indium-111-labeled leukocyte scintigraphy in hemodialysis access-site infection

    SciTech Connect

    Palestro, C.J.; Vega, A.; Kim, C.K.; Vallabhajosula, S.; Goldsmith, S.J. )

    1990-03-01

    Bacterial sepsis, a significant complication of chronic hemodialysis, is generally the result of infection at the vascular access site. We retrospectively reviewed the utility of indium-111-(111In) labeled autologous leukocyte scintigraphy in 26 patients (30 scans) with synthetic vascular grafts, on chronic hemodialysis, in whom hemodialysis access site infection was a diagnostic consideration. Leukocyte scintigraphy correctly identified all fifteen access-site infections; there was one false-positive study, for an overall sensitivity and specificity of 100% and 93%, respectively. Of particular significance is the fact that in nine (60%) of the fifteen access-site infections, physical examination was normal. Our data indicate that 111In-labeled leukocyte scintigraphy is a useful procedure for the diagnosis of hemodialysis access-site infection, and it is especially valuable when physical examination of the access site is normal.

  9. Correlation between bone imaging and the clinical picture in two unsuspected cases of progressive diaphyseal dysplasia (Engelmann's disease).

    PubMed

    D'Addabbo, A; Macarini, L; Rubini, G; Rubini, D; Salzillo, F; Lauriero, F

    1993-04-01

    Progressive diaphyseal dysplasia was incidentally discovered in two patients referred for Tc-99m MDP bone scintigraphy (one for intense sciatica, the other for the detection of breast cancer metastases). Tracer accumulation in the diaphyses of the lower limbs and the base of the skull was accompanied by bone thickening and patency of the medullary cavity, as demonstrated by radiography, MRI, and bone marrow scanning. Comparison of the clinical pictures with the results of instrumental examinations showed that these were cases of sporadic progressive diaphyseal dysplasia of slight and average gravity, respectively. The differentiation of Ribbing's disease is explained and reference also is made to a finding not mentioned in the literature, namely frontal bone resorption lacunules in one patient. PMID:8482029

  10. Bone grafts in dentistry

    PubMed Central

    Kumar, Prasanna; Vinitha, Belliappa; Fathima, Ghousia

    2013-01-01

    Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation. PMID:23946565

  11. Bone Marrow Transplantation

    MedlinePlus

    Bone marrow is the spongy tissue inside some of your bones, such as your hip and thigh bones. It contains immature cells, called stem cells. The ... platelets, which help the blood to clot. A bone marrow transplant is a procedure that replaces a ...

  12. Analysis and design of planar and non-planar wings for induced drag minimization

    NASA Technical Reports Server (NTRS)

    Mortara, Karl W.; Straussfogel, Dennis M.; Maughmer, Mark D.

    1992-01-01

    The goal of the work reported herein is to develop and validate computational tools to be used for the design of planar and non-planar wing geometries for minimum induced drag. Because of the iterative nature of the design problem, it is important that, in addition to being sufficiently accurate for the problem at hand, these tools need to be reasonably fast and computationally efficient. Toward this end, a method of predicting induced drag in the presence of a free wake has been coupled with a panel method. The induced drag prediction technique is based on the application of the Kutta-Joukowski law at the trailing edge. Until now, the use of this method has not been fully explored and pressure integration and Trefftz-plane calculations favored. As is shown in this report, however, the Kutta-Joukowski method is able to give better results for a given amount of effort than the more commonly used techniques, particularly when relaxed wakes and non-planar wing geometries are considered. Using these methods, it is demonstrated that a reduction in induced drag can be achieved through non-planar wing geometries. It remains to determine what overall drag reductions are possible when the induced drag reduction is traded-off against increased wetted area. With the design methodology that is described herein, such trade studies can be performed in which the non-linear effects of the free wake are taken into account.

  13. General lossless planar coupler design algorithms.

    PubMed

    Vance, Rod

    2015-08-01

    This paper reviews and extends two classes of algorithms for the design of planar couplers with any unitary transfer matrix as design goals. Such couplers find use in optical sensing for fading free interferometry, coherent optical network demodulation, and also for quantum state preparation in quantum optical experiments and technology. The two classes are (1) "atomic coupler algorithms" decomposing a unitary transfer matrix into a planar network of 2×2 couplers, and (2) "Lie theoretic algorithms" concatenating unit cell devices with variable phase delay sets that form canonical coordinates for neighborhoods in the Lie group U(N), so that the concatenations realize any transfer matrix in U(N). As well as review, this paper gives (1) a Lie theoretic proof existence proof showing that both classes of algorithms work and (2) direct proofs of the efficacy of the "atomic coupler" algorithms. The Lie theoretic proof strengthens former results. 5×5 couplers designed by both methods are compared by Monte Carlo analysis, which would seem to imply atomic rather than Lie theoretic methods yield designs more resilient to manufacturing imperfections. PMID:26367295

  14. Planar Particle Imaging Doppler Velocimetry Developed

    NASA Technical Reports Server (NTRS)

    Wernet, Mark P.

    2000-01-01

    Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components

  15. Complementary roles of brain scintigraphy and computed tomography in multiple sclerosis

    SciTech Connect

    Moreno, A.J.; Brown, J.M.; Waller, S.F.; Lundy, M.M.; Brown, T.J.

    1983-12-01

    Cerebral computed tomography, with and without iodinated contrast, revealed the appearance and evolution of lesions in a 32-year-old man with multiple sclerosis. Two areas were enhanced with contrast, with one showing a mild mass effect and rim of enhancement. Serial brain scintigraphy using technetium-/sub 99m/ glucoheptonate, following the computed tomography, showed the appearance and regression of corresponding regions of increased uptake. Computed tomography one day prior to brain scintigraphy failed to demonstrate a region of increased accumulation of radiotracer. One week later, however, evidence of a corresponding unenhanced defect was noted on computed tomography. Clinical correlation is given additionally.

  16. Early diagnosis of acute postoperative renal transplant rejection by indium-111-labeled platelet scintigraphy

    SciTech Connect

    Tisdale, P.L.; Collier, B.D.; Kauffman, H.M.; Adams, M.B.; Isitman, A.T.; Hellman, R.S.; Hoffmann, R.G.; Rao, S.A.; Joestgen, T.; Krohn, L.

    1986-08-01

    A prospective evaluation of /sup 111/In-labeled platelet scintigraphy (IPS) for the early diagnosis of acute postoperative renal transplant rejection (TR) was undertaken. The results of IPS were compared with in vitro biochemical tests, the clinical finding of graft tenderness, and combined (/sup 99m/Tc)DTPA and (/sup 131/I)orthoiodohippurate scintigraphy. With a sensitivity of 0.93 and a specificity of 0.95, IPS provided otherwise unavailable diagnostic information. Furthermore, postoperative IPS was a good predictor of long-term allograft survival.

  17. /sup 57/Co-bleomycin scintigraphy for the staging of lung cancer

    SciTech Connect

    Nieweg, O.E.; Piers, D.A.; Beekhuis, H.; Sluiter, H.J.; van der Wal, A.M.; Woldring, M.G.

    1989-03-15

    The value of Cobalt-57 bleomycin (/sup 57/Co-BLM) scintigraphy in the detection of lymph node metastases in the hilum and mediastinum was investigated in 132 patients with peripherally located lung cancer. In one half of the patients with metastases, these were visualized. Specificity was 98%. These results were better than those obtained with chest radiography and conventional roentgen tomography. /sup 57/Co-BLM scintigraphy is routinely used in the staging of patients with lung cancer, obviating the need for mediastinoscopy.

  18. Thallium-201 scintigraphy in the diagnosis and management of myocardial sarcoidosis

    SciTech Connect

    Fields, C.L.; Ossorio, M.A.; Roy, T.M.; Denny, D.M.; Varga, D.W. )

    1990-03-01

    We have described three patients with clinical evidence of myocardial sarcoidosis to illustrate the utility of thallium-201 scintigraphy in demonstrating the myocardial lesions. Both the symptomatic and asymptomatic individuals studied showed the characteristic reverse redistribution phenomenon. No abnormalities were seen during the exercise phase of the thallium study, but myocardial defects were detected in each patient when repeat studies were obtained at rest six hours later. Steroid therapy resolved the defects in each case. We propose thallium-201 scintigraphy of the heart as a safe and useful tool for documenting myocardial involvement in sarcoidosis and following the effects of therapy.

  19. Strategy for the use of biliary scintigraphy in non-iatrogenic biliary trauma

    SciTech Connect

    Zeman, R.K.; Lee, C.H.; Stahl, R.; Viscomi, G.N.; Baker, C.; Cahow, C.E.; Dobbins, J.; Neumann, R.; Burrell, M.I.

    1984-06-01

    Biliary scintigraphy was used to examine 21 patients who had suspected non-iatrogenic biliary trauma. Seven patients (33%) had scintigraphic evidence of biliary leakage. Ultimately, surgical biliary repair was required for only three of these patients. Visualization of the gallbladder did not occur in eight trauma patients, but only one patient was shown to have cholecystitis. In this series, 16 patients had Tc-99m sulfur colloid scans that offered no significant advantage over cholescintigraphy in the detection of hepatic parenchymal defects. Biliary scintigraphy provides clinically useful information in cases both of blunt and penetrating trauma.

  20. Strategy for use of biliary scintigraphy in non-iatrogenic biliary trauma

    SciTech Connect

    Zeman, R.K.; Lee, C.H.; Stahl, R.; Viscomi, G.N.; Baker, C.; Cahow, C.E.; Dobbins, J.; Neumann, R.; Burrell, M.I.

    1984-06-01

    Biliary scintigraphy was used to examine 21 patients who had suspected non-iatrogenic biliary trauma. Seven patients (33%) had scintigraphic evidence of biliary leakage. Ultimately, surgical biliary repair was required for only three of these patients. Visualization of the gallbladder did not occur in eight trauma patients, but only one patient was shown to have cholecystitis. In this series, 16 patients had Tc-99m sulfur colloid scans that offered no significant advantage over cholescintigraphy in the detection of hepatic parenchymal defects. Biliary scintigraphy provides clinically useful information in cases both of blunt and penetrating trauma.

  1. Scintigraphy and Arteriography in the Diagnosis of Diseases of the Liver

    PubMed Central

    Wang, I.; Wood, D. E.; Colapinto, R. F.; Langer, B.

    1971-01-01

    Arteriograms and scans performed over a five-year period on 60 patients with suspect hepatic disease have been reviewed. The diagnosis was proved in every case by biopsy, autopsy or laparotomy. Scintigraphy correctly predicted the presence or absence of disease in 75% and arteriography in 75% of cases. Fifty-four of the patients had hepatic disease. In 81% of these the accurate diagnosis of diffuse or localized disease was made by one or both techniques. Arteriography is preferred for the detection of localized lesions, but diffuse processes are more readily demonstrated by scintigraphy. ImagesFIG. 1FIG. 2FIG. 3FIG. 4 PMID:5089639

  2. Pulmonary evaluation of patients with osteosarcoma: roles of standard radiography, tomography, CT, scintigraphy, and tomoscintigraphy

    SciTech Connect

    Vanel, D.; Henry-Amar, M.; Lumbroso, J.; Lemalet, E.; Couanet, D.; Piekarski, J.D.; Masselot, J.; Boddaert, A.; Kalifa, C.; Le Chevalier, T.

    1984-09-01

    Sixty-one radiologic evaluations were performed on 32 patients with possible pulmonary metastases from osteosarcoma. CT scanning was performed 61 times; standard chest radiography, 58; tomography, 36; scintigraphy, 40; and tomoscintigraphy, 33. Using CT as a reference, the sensitivities of the other examinations were 57% (32% of total metastases) for standard radiography, 88% (48%) for tomography, 21% (5%) for scintigraphy, and 41% (8%) for tomoscintigraphy. Of the 193 metastases, 98 were subpleural and 95 were parenchymatous. The authors' current evaluation of patients with metastases from osteosarcoma includes chest radiography and CT; the other three examinations are performed only before surgery.

  3. [Imaging of hyperparathyroidism-Ultrasonography and 99mTc-MIBI scintigraphy-].

    PubMed

    Kawabe, Joji; Higashiyama, Shigeaki; Yoshida, Atsushi; Kotani, Kohei; Shiomi, Susumu

    2016-06-01

    Treatments for primary hyperparathyroidism due to adenoma, hyperplasia and carcinoma and secondary hyperparathyroidism are mainly surgical resections of them. Accurate imaging diagnoses of the existences and the regions are very important for reductions of invasiveness. We describe ultrasonography and 99mTc-MIBI scintigraphy of hyperparathyroidism. We explain an advantage, a disadvantage and diagnosability of these modalities. We mention utilities of SPECT/CT, too. We show echogram and 99mTc-MIBI scintigraphy images about 3 cases of hyperparathyroidism. PMID:27230842

  4. Research on planar antennas and arrays - 'Structures Rayonnantes'

    NASA Astrophysics Data System (ADS)

    Daniel, J. P.; Dubost, G.; Terret, C.; Citerne, J.; Drissi, M.

    1993-02-01

    Radiating antenna structures related to flat and wire antennas developed by the laboratory 'Structures Rayonnantes' of the University of Rennes I (France) are discussed with emphasis on flat antennas and arrays studied during the last three years and on their typical applications. Particular attention is given to basic planar radiating sources including patches with coaxial or microstrip feed, printed slots, slot-fed patches, slot-loaded patches, and electromagnetic coupled dipoles and patches; planar arrays including planar phased and planar passive arrays and dual-beam printed antennas; and arrays of microstrip dipoles.

  5. Planarization of topography with spin-on carbon hard mask

    NASA Astrophysics Data System (ADS)

    Noya, Go; Hama, Yusuke; Ishii, Maki; Nakasugi, Shigemasa; Kudo, Takanori; Padmanaban, Munirathna

    2016-03-01

    Spin-on-carbon hard mask (SOC HM) has been used in semiconductor manufacturing since 45nm node as an alternative carbon hard mask process to chemical vapor deposition (CVD). As advancement of semiconductor to 2X nm nodes and beyond, multiple patterning technology is used and planarization of topography become more important and challenging ever before. In order to develop next generation SOC, one of focuses is planarization of topography. SOC with different concepts for improved planarization and the influence of thermal flow temperature, crosslink, film shrinkage, baking conditions on planarization and filling performance are described in this paper.

  6. Does running strengthen bone?

    PubMed

    Boudenot, Arnaud; Achiou, Zahra; Portier, Hugues

    2015-12-01

    Bone is a living tissue needing mechanical stress to maintain strength. Traditional endurance exercises offer only modest effects on bone. Walking and running produce low impact but lead to bone fatigue. This article is specifically addressed to therapists and explains the mechanisms involved for the effects of exercise on bone. Intermittent exercise limits bone fatigue, and downhill exercises increase ground impact forces and involve eccentric muscle contractions, which are particularly osteogenic. PMID:26562001

  7. Basic bone radiology

    SciTech Connect

    Griffiths, H.J.

    1987-01-01

    This clinical book surveys the skeletal system as seen through radiological imaging. It emphasizing abnormalities, disease, and trauma, and includes vital information on bones, bone growth, and the cells involved in bone pathology. It covers many bone diseases and injuries which are rarely covered in medical texts, as well as descriptions of radiologic procedures that specifically relate to the skeleton. This edition includes many illustrations, information on MR imaging and CT scanning, and discussions of osteoporosis, dysplasias, and metabolic bone disease.

  8. Detection of avascular necrosis in adults by single photon emission computed tomography

    SciTech Connect

    Collier, B.D.; Johnston, R.P.; Carrera, G.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.

    1984-01-01

    Twenty-one adult patients with the clinical diagnosis of avascular necrosis (AVN) of the femoral head were examined with planar bone scintigraphy (high resolution collimator) and single photon emission computed tomography (SPECT). The duration of hip pain ranged from 1 day to 18 months. Risk factors (including steroids, renal transplantation, alcoholism, and trauma) were present in 17 cases. A final diagnosis of AVN (20 hips), osteochondral facture, or stress fracture, was established for 17 patients. The 4 remaining patients, who were radiographically normal and did not complain of pain 3 months later, were thought to have no significant bone pathology. SPECT and planar bone scintigraphy were reported as positive for AVN only if a photopenic bony defect could be identified. In particular, uniformly increased activity throughout the femoral head was not considered to be diagnostic of AVN. The authors conclude that by identifying a photopenic defect which is not evident on planar bone scintigraphy, SPECT can contribute to accurate diagnosis of AVN.

  9. Anorexia nervosa and bone.

    PubMed

    Misra, Madhusmita; Klibanski, Anne

    2014-06-01

    Anorexia nervosa (AN) is a condition of severe low weight that is associated with low bone mass, impaired bone structure, and reduced bone strength, all of which contribute to increased fracture risk. Adolescents with AN have decreased rates of bone accrual compared with normal-weight controls, raising additional concerns of suboptimal peak bone mass and future bone health in this age group. Changes in lean mass and compartmental fat depots, and hormonal alterations secondary to nutritional factors contribute to impaired bone metabolism in AN. The best strategy to improve bone density is to regain weight and menstrual function. Oral estrogen-progesterone combinations are not effective in increasing bone density in adults or adolescents with AN, and transdermal testosterone replacement is not effective in increasing bone density in adult women with AN. However, physiological estrogen replacement as transdermal estradiol with cyclic progesterone does increase bone accrual rates in adolescents with AN to approximate that in normal-weight controls, leading to a maintenance of bone density Z-scores. A recent study has shown that risedronate increases bone density at the spine and hip in adult women with AN. However, bisphosphonates should be used with great caution in women of reproductive age, given their long half-life and potential for teratogenicity, and should be considered only in patients with low bone density and clinically significant fractures when non-pharmacological therapies for weight gain are ineffective. Further studies are necessary to determine the best therapeutic strategies for low bone density in AN. PMID:24898127

  10. Anorexia Nervosa and Bone

    PubMed Central

    Misra, Madhusmita; Klibanski, Anne

    2014-01-01

    Anorexia nervosa (AN) is a condition of severe low weight that is associated with low bone mass, impaired bone structure and reduced bone strength, all of which contribute to increased fracture risk., Adolescents with AN have decreased rates of bone accrual compared with normal-weight controls, raising addition concerns of suboptimal peak bone mass and future bone health in this age group. Changes in lean mass and compartmental fat depots, hormonal alterations secondary to nutritional factors contribute to impaired bone metabolism in AN. The best strategy to improve bone density is to regain weight and menstrual function. Oral estrogen-progesterone combinations are not effective in increasing bone density in adults or adolescents with AN, and transdermal testosterone replacement is not effective in increasing bone density in adult women with AN. However, physiologic estrogen replacement as transdermal estradiol with cyclic progesterone does increase bone accrual rates in adolescents with AN to approximate that in normal-weight controls, leading to a maintenance of bone density Z-scores. A recent study has shown that risedronate increases bone density at the spine and hip in adult women with AN. However, bisphosphonates should be used with great caution in women of reproductive age given their long half-life and potential for teratogenicity, and should be considered only in patients with low bone density and clinically significant fractures when non-pharmacological therapies for weight gain are ineffective. Further studies are necessary to determine the best therapeutic strategies for low bone density in AN. PMID:24898127

  11. Scintigraphy of infected total hip arthroplasty (THA): A canine model

    SciTech Connect

    Merkel, K.D.; Brown, M.L.; Fitzgerald, R.H.; Dewanjee, M.K.

    1984-01-01

    Differentiating low-grade sepsis from aseptic loosening of an orthopedic prosthesis is difficult. This study was designed to compare the ability of Tc-99m-HMDP, Ga-67, and In-111 leukocytes (WC) to differentiate low-grade sepsis from aseptic THA component loosening in a canine model. A canine THA was implanted in 14 dogs. Six dogs were given infected femoral components by injecting 10/sup 5/ colony-forming units of Staphylococcus aureus into the femoral canal 6y0 to 90 seconds prior to cementing. Four dogs had an aseptic loose femoral component, and four dogs had an aseptic tight femoral component (control). At six months all dogs were evaluated with X-ray, lab scintigraphy, and tissue quantitation of each tracer. Diagnosis was confirmed by histology and quantitative microbiology. White blood cell counts and differentials were normal in all dogs, and in only one out of six infected dogs was the sedimentation rate abnormal. X-rays were interpreted as possible infection in five dogs and probable infection in only one dog. In-111 WBC scans were more accurate than sequential Tc-Ga scans (sensitivity 94% vs 61%, specificity 86% vs 71% accuracy 90% vs 67%). Quantitative counting of gamma camera data and tissue samples demonstrated significantly (P < .01) higher accumulation of In-111 WBC about the infected than the loose or control component. No significant difference was demonstrated between the loose and septic components with TC-HMDP or Ga. These results correlate well and confirm our clinical data that In-111 WBC scanning is accurate and useful in the workup of the painful orthopedic prosthesis.

  12. Gated thallium scintigraphy in the assessment of coronary artery disease

    SciTech Connect

    Martin, W.; Tweddel, A.C.; McGhie, A.I.; McKillop, J.H.; Hutton, I.

    1984-01-01

    This study was aimed at assessing ECG gated images to provide both perfusion and ventricular function information. 18 patients with acute myocardial infarction were studied at rest, and 12 male volunteers and 55 male patients undergoing routine coronary angiography were studied following the injection of 2 mCi (80 MBq) of thallous chloride 30s prior to termination of a symptom limited maximal exercise. Listmode data gated to the ECG were obtained in 3 projections for 6 minutes using a mobile gamma camera with a high sensitivity collimator. Three independent observers, on separate occasions analysed firstly standard reconstructed thallium scintigrams and secondly cine display of the gated image for perfusion defects and regional wall motion (RWM) using a 4 point scoring system. In addition ejection fraction (EF) was calculated from the 45/sup 0/ LAO projection. The gated thallium EF ranged from 52-65% in the volunteers, from 24-65% in the angiography patients and from 13-61% in the acute infarcts, and correlated well against the gated blood pool (r=.84) and contrast angiography (r=.78). RWM assessed for 850 segments gave interobserver disagreement of 0.9% and when compared to gated blood pool scans, disagreement occurred in 2 of 77 segments (2.8%). In the detection of significant coronary disease static thallium images provided a sensitivity of 71% and overall predictive accuracy of 75%. If the perfusion and wall motion from the gated image were considered the sensitivity was 93% at a predictive accuracy of 90%. The authors conclude that multiple view gated thallium scintigraphy gives accurate information as to ventricular function and enhances the detection of perfusion defects.

  13. Towards a standard in assessment of bone cutting for total knee replacement.

    PubMed

    Barrera, O A; Haider, H; Garvin, K L

    2008-01-01

    Arthroplasty outcome is influenced by the 'quality' of bone preparation for implant insertion. Surgeons face increasing choices of technique and instrumentation, yet clinical scoring methods assess the overall outcome and patient satisfaction but not the bone cuts directly. 'Quality management' of bone reshaping is needed to evaluate different bone cutting methods and computer assisted orthopaedic surgery (CAOS) systems. Analyses and experiments in this study were formulated for measurement and computation of four quantitative characteristics of bone preparation 'quality' and produced a highly condensed index for each. These represented (a) surface finish of cuts, (b) implant fit/looseness possible with the cut shape, (c) implant location/misalignment, and (d) accuracy of individual planar cuts. Assessment of synthetic bone cuts verified the robustness of the method for wide application in arthroplasty intraoperatively, in vitro and for comparing navigation systems. PMID:18335719

  14. Water Permeability of Asymmetric Planar Lipid Bilayers

    PubMed Central

    Krylov, Andrey V.; Pohl, Peter; Zeidel, Mark L.; Hill, Warren G.

    2001-01-01

    To understand how plasma membranes may limit water flux, we have modeled the apical membrane of MDCK type 1 cells. Previous experiments demonstrated that liposomes designed to mimic the inner and outer leaflet of this membrane exhibited 18-fold lower water permeation for outer leaflet lipids than inner leaflet lipids (Hill, W.G., and M.L. Zeidel. 2000. J. Biol. Chem. 275:30176–30185), confirming that the outer leaflet is the primary barrier to permeation. If leaflets in a bilayer resist permeation independently, the following equation estimates single leaflet permeabilities: 1/PAB = 1/PA + 1/PB (Eq. l), where PAB is the permeability of a bilayer composed of leaflets A and B, PA is the permeability of leaflet A, and PB is the permeability of leaflet B. Using for the MDCK leaflet–specific liposomes gives an estimated value for the osmotic water permeability (Pf) of 4.6 × 10−4 cm/s (at 25°C) that correlated well with experimentally measured values in intact cells. We have now constructed both symmetric and asymmetric planar lipid bilayers that model the MDCK apical membrane. Water permeability across these bilayers was monitored in the immediate membrane vicinity using a Na+-sensitive scanning microelectrode and an osmotic gradient induced by addition of urea. The near-membrane concentration distribution of solute was used to calculate the velocity of water flow (Pohl, P., S.M. Saparov, and Y.N. Antonenko. 1997. Biophys. J. 72:1711–1718). At 36°C, Pf was 3.44 ± 0.35 × 10−3 cm/s for symmetrical inner leaflet membranes and 3.40 ± 0.34 × 10−4 cm/s for symmetrical exofacial membranes. From , the estimated permeability of an asymmetric membrane is 6.2 × 10−4 cm/s. Water permeability measured for the asymmetric planar bilayer was 6.7 ± 0.7 × 10−4 cm/s, which is within 10% of the calculated value. Direct experimental measurement of Pf for an asymmetric planar membrane confirms that leaflets in a bilayer offer independent and additive resistances to

  15. MCM Polarimetric Radiometers for Planar Arrays

    NASA Technical Reports Server (NTRS)

    Kangaslahti, Pekka; Dawson, Douglas; Gaier, Todd

    2007-01-01

    A polarimetric radiometer that operates at a frequency of 40 GHz has been designed and built as a prototype of multiple identical units that could be arranged in a planar array for scientific measurements. Such an array is planned for use in studying the cosmic microwave background (CMB). All of the subsystems and components of this polarimetric radiometer are integrated into a single multi-chip module (MCM) of substantially planar geometry. In comparison with traditional designs of polarimetric radiometers, the MCM design is expected to greatly reduce the cost per unit in an array of many such units. The design of the unit is dictated partly by a requirement, in the planned CMB application, to measure the Stokes parameters I, Q, and U of the CMB radiation with high sensitivity. (A complete definition of the Stokes parameters would exceed the scope of this article. In necessarily oversimplified terms, I is a measure of total intensity of radiation, while Q and U are measures of the relationships between the horizontally and vertically polarized components of radiation.) Because the sensitivity of a single polarimeter cannot be increased significantly, the only way to satisfy the high-sensitivity requirement is to make a large array of polarimeters that operate in parallel. The MCM includes contact pins that can be plugged into receptacles on a standard printed-circuit board (PCB). All of the required microwave functionality is implemented within the MCM; any required supporting non-microwave ("back-end") electronic functionality, including the provision of DC bias and control signals, can be implemented by standard PCB techniques. On the way from a microwave antenna to the MCM, the incoming microwave signal passes through an orthomode transducer (OMT), which splits the radiation into an h + i(nu) beam and an h - i(nu) beam (where, using complex-number notation, h denotes the horizontal component, nu denotes the vertical component, and +/-i denotes a +/-90deg phase

  16. Bisphosphonates and bone quality

    PubMed Central

    Pazianas, Michael; van der Geest, Stefan; Miller, Paul

    2014-01-01

    Bisphosphonates (BPs) are bone-avid compounds used as first-line medications for the prevention and treatment of osteoporosis. They are also used in other skeletal pathologies such as Paget's and metastatic bone disease. They effectively reduce osteoclast viability and also activity in the resorptive phase of bone remodelling and help preserve bone micro-architecture, both major determinants of bone strength and ultimately of the susceptibility to fractures. The chemically distinctive structure of each BP used in the clinic determines their unique affinity, distribution/penetration throughout the bone and their individual effects on bone geometry, micro-architecture and composition or what we call ‘bone quality'. BPs have no clinically significant anabolic effects. This review will touch upon some of the components of bone quality that could be affected by the administration of BPs. PMID:24876930

  17. [Microdestruction of the bone].

    PubMed

    Iankovskiĭ, V É

    2014-01-01

    The objective of the present study was the detection of microcracks in the compact bone tissue surrounding the fracture and in deformed bone undergoing subcritical loading. The portions of deformed bone tissue and terminal fragments of broken bones were obtained in the form of blocks longitudinally sawcut from the regions of primary and secondary bone rupture. A total of 300 such blocks were available for the examination. All portions of the deformed bone tissue and terminal fragments of broken bones showed up microcracks commensurate with the bone structures. They were actually hardened traces of deformation that preceded the fracture and reflected the volume of the destroyed bone tissue; moreover, in certain cases they allowed to identify the kind of the object that exerted the external action (either a blow or slow bending). PMID:25269164

  18. Bone tissue response to plasma-nitrided titanium implant surfaces.

    PubMed

    Ferraz, Emanuela Prado; Sverzut, Alexander Tadeu; Freitas, Gileade Pereira; Sá, Juliana Carvalho; Alves, Clodomiro; Beloti, Marcio Mateus; Rosa, Adalberto Luiz

    2015-01-01

    A current goal of dental implant research is the development of titanium (Ti) surfaces to improve osseointegration. Plasma nitriding treatments generate surfaces that favor osteoblast differentiation, a key event to the process of osteogenesis. Based on this, it is possible to hypothesize that plasma-nitrided Ti implants may positively impact osseointegration. Objective The aim of this study was to evaluate the in vivo bone response to Ti surfaces modified by plasma-nitriding treatments. Material and Methods Surface treatments consisted of 20% N2 and 80% H2, 450°C and 1.5 mbar during 1 h for planar and 3 h for hollow cathode. Untreated surface was used as control. Ten implants of each surface were placed into rabbit tibiae and 6 weeks post-implantation they were harvested for histological and histomorphometric analyses. Results Bone formation was observed in contact with all implants without statistically significant differences among the evaluated surfaces in terms of bone-to-implant contact, bone area between threads, and bone area within the mirror area. Conclusion Our results indicate that plasma nitriding treatments generate Ti implants that induce similar bone response to the untreated ones. Thus, as these treatments improve the physico-chemical properties of Ti without affecting its biocompatibility, they could be combined with modifications that favor bone formation in order to develop new implant surfaces. PMID:25760262

  19. Bone tissue response to plasma-nitrided titanium implant surfaces

    PubMed Central

    FERRAZ, Emanuela Prado; SVERZUT, Alexander Tadeu; FREITAS, Gileade Pereira; SÁ, Juliana Carvalho; ALVES, Clodomiro; BELOTI, Marcio Mateus; ROSA, Adalberto Luiz

    2015-01-01

    A current goal of dental implant research is the development of titanium (Ti) surfaces to improve osseointegration. Plasma nitriding treatments generate surfaces that favor osteoblast differentiation, a key event to the process of osteogenesis. Based on this, it is possible to hypothesize that plasma-nitrided Ti implants may positively impact osseointegration. Objective The aim of this study was to evaluate the in vivo bone response to Ti surfaces modified by plasma-nitriding treatments. Material and Methods Surface treatments consisted of 20% N2 and 80% H2, 450°C and 1.5 mbar during 1 h for planar and 3 h for hollow cathode. Untreated surface was used as control. Ten implants of each surface were placed into rabbit tibiae and 6 weeks post-implantation they were harvested for histological and histomorphometric analyses. Results Bone formation was observed in contact with all implants without statistically significant differences among the evaluated surfaces in terms of bone-to-implant contact, bone area between threads, and bone area within the mirror area. Conclusion Our results indicate that plasma nitriding treatments generate Ti implants that induce similar bone response to the untreated ones. Thus, as these treatments improve the physico-chemical properties of Ti without affecting its biocompatibility, they could be combined with modifications that favor bone formation in order to develop new implant surfaces. PMID:25760262

  20. Metamodels for Planar 3R Workspace Optimization.

    SciTech Connect

    Turner, C. J.

    2002-01-01

    Robotic workspace optimization is a central element of robot system design. To formulate the optimization problem, the complex relationships between design variables, tuning parameters, and performance indices need to be accurately and efficiently represented. The nature of the relationships suggests that metamodels, or models of the models, should be used to derive suitable objective functions. A comparison of two metamodeling techniques for robotic workspace optimization problems for several trial cases suggests that non-uniform rational B-spline models, derived from computer graphics and computer-aided design techniques, are as suitable as response surface models to solve planar 3R workspace optimization problems. Promising nonlinear modeling results with B-spline models suggest future work is justified and performance gains can be realized.

  1. Development of Osaka gas type planar SOFC

    SciTech Connect

    Iha, M.; Shiratori, A.; Chikagawa, O.

    1996-12-31

    Osaka Gas Co. has been developing a planar type SOFC (OG type SOFC) which has a suitable structure for stacking. Murata Mfg. Co. has begun to develop the OG type SOFC stack through joint program since 1993. Figure 1 shows OG type cell structure. Because each cell is sustained by cell holders acting air manifold, the load of upper cell is not put on the lower cells. Single cell is composed of 3-layered membrane and LaCrO{sub 3} separator. 5 single cells are mounted on the cell holder, connected with Ni felt electrically, and bonded by glassy material sealant. We call the 5-cell stack a unit. Stacking 13 units, we succeeded 870 W generation in 1993. But the power density was low, 0.11 Wcm{sup -2} because of crack in the electrolyte and gas leakage at some cells.

  2. All-metal superconducting planar microwave resonator

    NASA Astrophysics Data System (ADS)

    Horsley, Matt; Pereverzev, Sergey; Dubois, Jonathon; Friedrich, Stephan; Qu, Dongxia; Libby, Steve; Lordi, Vincenzo; Carosi, Gianpaolo; Stoeffl, Wolfgang; Chapline, George; Drury, Owen; Quantum Noise in Superconducting Devices Team

    There is common agreement that noise and resonance frequency jitter in superconducting microwave planar resonators are caused by presence of two-level systems, or fluctuators, in resonator materials- in dielectric substrate, in superconducting and dielectric layers and on the boundaries and interfaces. Scaling of noise with device dimensions indicate that fluctuators are likely concentrated around boundaries; physical nature of those fluctuators remains unclear. The presence of dielectrics is not necessary for the superconducting device functionality, and one can ask question about properties of all-metal device, where dielectric substrate and oxide films on metal are absent. Resonator made from of thin conducting layer with cuts in it is usually called slot line resonator. We report on the design, fabrication and initial testing of multiple split rings slot line resonator made out of thin molybdenum plate. This work is being funded as part of a three year strategic initiative (LDRD 16-SI-004) to better understand noise in superconducting devices.

  3. Planarity of nitro-substituted phenothiazines.

    PubMed

    Brock, C P; DeLaLuz, P J; Golinski, M; Lloyd, M A; Vanaman, T C; Watt, D S

    1996-08-01

    The structures of three nitro-substituted phenothiazines [1,3,4-trifluoro-2-nitrophenothiazine, 10-(4-chlorobutyl)-1,3,4-trifluoro-2-nitrophenothiazine and 10-(4-chlorobutyl)-3-nitrophenothiazine] have been determined. The first of these red compounds forms infinite stacks in the solid state, in which donor and acceptor regions of the approximately planar molecules alternate. The molecules of the other two compounds, which have folded, or 'butterfly', conformations in the solid state, do not form stacks, presumably because the bulky chlorobutyl substituents cannot be accommodated. The very dark color of solid 3-nitrophenothiazine suggests the presence of extended molecular stacks, but crystals suitable for a structure determination could not be obtained. PMID:8810494

  4. Planar-constructed spatial micro-stage

    DOEpatents

    Jokiel, Jr., Bernhard; Benavides, Gilbert L.; Bieg, Lothar F.; Allen, James J.

    2004-01-13

    A multiple degree of freedom platform assembly formed from a plurality of thin films on a substrate can, when activated, move out of the plane of the substrate without additional manufacturing steps. The platform is connected to the substrate by at least three linkages, each linkage being pivotally connected to the platform and the base. At least two of the base connections are to powered traveling devices that are manufactured at one end of a path and which may be moved to locations along the path to cause the platform to move to predetermined positions. The entire assembly, including hinges, is manufactured as planar structures; preferably by a thin film technology such as MEMS.

  5. Multi-axis planar slide system

    DOEpatents

    Bieg, Lothar F.

    2002-01-01

    An apparatus for positioning an item that provides two-dimensional, independent orthogonal motion of a platform in a X-Y plane. A pair of master and slave disks engages opposite sides of the platform. Rotational drivers are connected to master disks so the disks rotate eccentrically about axes of rotation. Opposing slave disks are connected to master disks on opposite sides of the platform by a timing belt, or are electronically synchronized together using stepper motors, to effect coordinated motion. The coordinated eccentric motion of the pairs of master/slave disks compels smooth linear motion of the platform in the X-Y plane without backlash. The apparatus can be a planar mechanism implemented in a MEMS device.

  6. Photonic bandgap structures in planar waveguides.

    PubMed

    Ctyroký, J

    2001-02-01

    If a one-dimensional (1D) or two-dimensional (2D) photonic bandgap (PBG) structure is incorporated into a planar optical waveguide, the refractive-index nonuniformity in the direction perpendicular to the waveguide plane responsible for waveguiding may affect its behavior detrimentally. Such influence is demonstrated in the paper by numerical modeling of a deeply etched first-order waveguide Bragg grating. On the basis of physical considerations, a simple condition for the design of 1D and 2D waveguide PBG structures free of this degradation is formulated; it is, in fact the separability condition for the wave equation. Its positive effect is verified by numerical modeling of a modified waveguide Bragg grating that fulfills the separability condition. PMID:11205991

  7. Electrodynamics of planar Archimedean spiral resonator

    NASA Astrophysics Data System (ADS)

    Maleeva, N.; Averkin, A.; Abramov, N. N.; Fistul, M. V.; Karpov, A.; Zhuravel, A. P.; Ustinov, A. V.

    2015-07-01

    We present a theoretical and experimental study of electrodynamics of a planar spiral superconducting resonator of a finite length. The resonator is made in the form of a monofilar Archimedean spiral. By making use of a general model of inhomogeneous alternating current flowing along the resonator and specific boundary conditions on the surface of the strip, we obtain analytically the frequencies fn of resonances which can be excited in such system. We also calculate corresponding inhomogeneous RF current distributions ψ n ( r ) , where r is the coordinate across a spiral. We show that the resonant frequencies and current distributions are well described by simple relationships f n = f 1 n and ψ n ( r ) ≃ sin [ π n ( r / R e ) 2 ] , where n = 1 , 2... and Re is the external radius of the spiral. Our analysis of electrodynamic properties of spiral resonators' is in good agreement with direct numerical simulations and measurements made using specifically designed magnetic probe and laser scanning microscope.

  8. Planar optics with patterned chiral liquid crystals

    NASA Astrophysics Data System (ADS)

    Kobashi, Junji; Yoshida, Hiroyuki; Ozaki, Masanori

    2016-06-01

    Reflective metasurfaces based on metallic and dielectric nanoscatterers have attracted interest owing to their ability to control the phase of light. However, because such nanoscatterers require subwavelength features, the fabrication of elements that operate in the visible range is challenging. Here, we show that chiral liquid crystals with a self-organized helical structure enable metasurface-like, non-specular reflection in the visible region. The phase of light that is Bragg-reflected off the helical structure can be controlled over 0–2π depending on the spatial phase of the helical structure; thus planar elements with arbitrary reflected wavefronts can be created via orientation control. The circular polarization selectivity and external field tunability of Bragg reflection open a wide variety of potential applications for this family of functional devices, from optical isolators to wearable displays.

  9. Organic hybrid planar-nanocrystalline bulk heterojunctions

    DOEpatents

    Forrest, Stephen R.; Yang, Fan

    2011-03-01

    A photosensitive optoelectronic device having an improved hybrid planar bulk heterojunction includes a plurality of photoconductive materials disposed between the anode and the cathode. The photoconductive materials include a first continuous layer of donor material and a second continuous layer of acceptor material. A first network of donor material or materials extends from the first continuous layer toward the second continuous layer, providing continuous pathways for conduction of holes to the first continuous layer. A second network of acceptor material or materials extends from the second continuous layer toward the first continuous layer, providing continuous pathways for conduction of electrons to the second continuous layer. The first network and the second network are interlaced with each other. At least one other photoconductive material is interspersed between the interlaced networks. This other photoconductive material or materials has an absorption spectra different from the donor and acceptor materials.

  10. Organic hybrid planar-nanocrystalline bulk heterojunctions

    DOEpatents

    Forrest, Stephen R.; Yang, Fan

    2013-04-09

    A photosensitive optoelectronic device having an improved hybrid planar bulk heterojunction includes a plurality of photoconductive materials disposed between the anode and the cathode. The photoconductive materials include a first continuous layer of donor material and a second continuous layer of acceptor material. A first network of donor material or materials extends from the first continuous layer toward the second continuous layer, providing continuous pathways for conduction of holes to the first continuous layer. A second network of acceptor material or materials extends from the second continuous layer toward the first continuous layer, providing continuous pathways for conduction of electrons to the second continuous layer. The first network and the second network are interlaced with each other. At least one other photoconductive material is interspersed between the interlaced networks. This other photoconductive material or materials has an absorption spectra different from the donor and acceptor materials.

  11. A planar quasi-optical SIS receiver

    NASA Technical Reports Server (NTRS)

    Stimson, Philip A.; Dengler, Robert J.; Leduc, Henry G.; Cypher, Scott R.; Siegel, Peter H.

    1993-01-01

    A planar, quasi-optical SIS receiver operating at 230 GHz is described. The receiver consists of a 2 x 5 array of half wave dipole antennas with ten niobium-aluminum oxide-niobium SIS junctions on a quartz dielectric-filled parabola. The 1.4 GHz intermediate frequency is coupled from the mixer via coplanar strip transmission lines and 4:1 balun transformers. The receiver is operated at 4.2 K in a liquid helium immersion cryostat. We report accurate measurements of the performance of single receiver elements. A mixer noise temperature of 89 K DSB, receiver noise temperature of 156 K DSB, and conversion loss of 3 dB into a matched load have been obtained.

  12. Exact formation of hairy planar black holes

    NASA Astrophysics Data System (ADS)

    Fan, Zhong-Ying; Chen, Bin

    2016-04-01

    We consider Einstein gravity minimally coupled to a scalar field with a given potential in general dimensions. We obtain large classes of static hairy planar black holes which are asymptotic to anti-de Sitter (AdS) space-times. In particular, for a special case μ =(n -2 )/2 , we obtain new classes of exact dynamical solutions describing black hole formation. We find there are two classes of collapse solutions. The first class of solutions describes the evolution start from AdS space-time with a naked singularity at the origin. The space-time is linearly unstable and evolves into stationary black hole states even under small perturbation. The second class of solutions describes the space-time spontaneously evolving from AdS vacua into stationary black hole states undergoing nonlinear instability. We also discuss the global properties of all these dynamical solutions.

  13. Planar dipolar polymer brush: field theoretical investigations

    NASA Astrophysics Data System (ADS)

    Mahalik, Jyoti; Kumar, Rajeev; Sumpter, Bobby

    2015-03-01

    Physical properties of polymer brushes bearing monomers with permanent dipole moments and immersed in a polar solvent are investigated using self-consistent field theory (SCFT). It is found that mismatch between the permanent dipole moments of the monomer and the solvent plays a significant role in determining the height of the polymer brush. Sign as well as magnitude of the mismatch determines the extent of collapse of the polymer brush. The mismatch in the dipole moments also affects the force-distance relations and interpenetration of polymers in opposing planar brushes. In particular, an attractive force between the opposing dipolar brushes is predicted for stronger mismatch parameter. Furthermore, effects of added monovalent salt on the structure of dipolar brushes will also be presented. This investigation highlights the significance of dipolar interactions in affecting the physical properties of polymer brushes. Csmd division, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN 37831, USA.

  14. Photoemission spectroscopy of planar and nanostructured surfaces

    NASA Astrophysics Data System (ADS)

    Gervasoni, J. L.

    2016-02-01

    In this paper, I present some results for the process of excitation of bulk and surface plasmons during the emission of electrons in the proximity of surfaces of different shapes and dimensions. I describe in detail the effects due to the interaction between an electron and a stationary positive ion (or atomic hole) in the neighborhood of a metallic surface, paying special attention to the results obtained by my research group. We used the dielectric response of the metal and the specular reflection model for the case of planar surfaces, and the second quantization theory for nanostructured surfaces. In particular, we studied how the electron-hole pair interaction can influence the energy loss of the emerging electron. We investigated the importance of surface effects in the analysis of photoelectron spectroscopy. The method described here is useful for studying multiple plasmon excitations in nanostructures and for understanding the excited electron spectra of these nanostructures (different from those of the same bulk material).

  15. Planar electrostatic gradiometer for airborne geodesy

    NASA Astrophysics Data System (ADS)

    Foulon, B.; Christophe, B.; Lebat, V.; Boulanger, D.

    2011-12-01

    The knowledge of the gravity field of the Earth has been considerably improved for the last decades, thanks to satellites, in particular, both for gravity measurements and positioning. Gravity, and especially gravity gradiometry data are then of great interest to the study of the structure of the continental margins. Space gravity measurements, in particular with the GOCE satellite in orbit since 2009, provide an absolute gravity reference and should contribute to estimate the systematic effects that would affect the surface datasets. But the spatial resolution of those data essentially addresses the large and medium wavelengths of the field (down to a resolution of 90km) and it is therefore essential to complete them at the shorter wavelengths in particular in the littoral area. To this aim, gravity gradiometry systems may be particularly suitable by covering the land/sea transition zone with a uniform precision, and a spatial resolution higher than from gravimetry. The GREMLIT instrument is taking advantage of technologies, formerly developed by ONERA for the GRACE and GOCE space missions, by adapting them to an airborne environment, using a planar configuration for the gradiometer and designing and building a dedicated stabilized platform controlled by the common mode outputs of the instrument itself similarly to the drag free control of the GOCE satellite. The mains interests of the planar configuration are: - its definition, optimized for levitation in the Earth's gravity field ; - its intrinsic linearity, which minimizes the aliasing due to high frequency vibrations or motions generated outside the measurement bandwidth ; - its compactness, ensuring an excellent dimensional stability, a better thermal homogeneity and making the realization of the decoupling platform easier. The performance objective is 0.1 Eötvös. This lowered performance level with respect to a one hundred times better GOCE-type instrument, takes into account the difficulty of measurements

  16. Polymer planar Bragg grating for sensing applications

    NASA Astrophysics Data System (ADS)

    Rosenberger, M.; Hartlaub, N.; Koller, G.; Belle, S.; Schmauss, B.; Hellmann, R.

    2013-05-01

    Bragg gratings have become indispensable as optical sensing elements and are already used for a variety of technical applications. Mainly silica fiber Bragg gratings (FBGs) have been extensively studied over the last decades and are nowadays commercially available. Bragg grating sensors consisting of other materials like polymers, however, have only recently come into the focus of fundamental and applied research. Polymers exhibit significantly different properties advantageous for many sensing applications and therefore provide a good alternative to silica based devices. In addition, polymer materials are inexpensive, simple to handle as well as available in various forms like liquid resists or bulk material. Accordingly, polymer integrated optics attract increasing interest and can serve as a substitute for optical fibers. We report on the fabrication of a planar Bragg grating sensor in bulk Polymethylmethacrylate (PMMA). The sensor consists of an optical waveguide and a Bragg grating, both written simultaneously into a PMMA chip by a single writing step, for which a phase mask covered by an amplitude mask is placed on top of the PMMA and exposed to the UV radiation of a KrF excimer laser. Depending on the phase mask period, different Bragg gratings reflecting in the telecommunication wavelength range are fabricated and characterized. Reflection and transmission measurements show a narrow reflection band and a high reflectivity of the polymer planar Bragg grating (PPBG). After connecting to a single mode fiber, the portable PPBG based sensor was evaluated for different measurands like humidity and strain. The sensor performance was compared to already existing sensing systems. Due to the obtained results as well as the rapid and cheap fabrication of the sensor chip, the PPBG qualifies for a low cost sensing element.

  17. Unsteady planar diffusion flames: Ignition, travel, burnout

    NASA Technical Reports Server (NTRS)

    Fendell, F.; Wu, F.

    1995-01-01

    In microgravity, a thin planar diffusion flame is created and thenceforth travels so that the flame is situated at all times at an interface at which the hydrogen and oxygen meet in stoichiometric proportion. If the initial amount of hydrogen is deficient relative to the initial amount of oxygen, then the planar flame will travel further and further into the half volume initially containing hydrogen, until the hydrogen is (virtually) fully depleted. Of course, when the amount of residual hydrogen becomes small, the diffusion flame is neither vigorous nor thin; in practice, the flame is extinguished before the hydrogen is fully depleted, owing to the finite rate of the actual chemical-kinetic mechanism. The rate of travel of the hydrogen-air diffusion flame is much slower than the rate of laminar flame propagation through a hydrogen-air mixture. This slow travel facilitates diagnostic detection of the flame position as a function of time, but the slow travel also means that the time to burnout (extinction) probably far exceeds the testing time (typically, a few seconds) available in earth-sited facilities for microgravity-environment experiments. We undertake an analysis to predict (1) the position and temperature of the diffusion flame as a function of time, (2) the time at which extinction of the diffusion flame occurs, and (3) the thickness of quench layers formed on side walls (i.e., on lateral boundaries, with normal vectors parallel to the diffusion-flame plane), and whether, prior to extinction, water vapor formed by burning will condense on these cold walls.

  18. Semi-Euclidean quasi-elliptic planar motion

    NASA Astrophysics Data System (ADS)

    Bekar, Murat; Yayli, Yusuf

    2016-06-01

    The aim of this paper is to study the algebra of split semi-quaternions with their basic properties. Also, the results of the Euclidean planar motion given by Blaschke and Grünwald is generalized to semi-Euclidean planar motion by using the algebra of split semi-quaternions.

  19. Beam-pointing errors of planar-phased arrays.

    NASA Technical Reports Server (NTRS)

    Carver, K. R.; Cooper, W. K.; Stutzman, W. L.

    1973-01-01

    Using both analytical and Monte Carlo techniques, beam-pointing errors of planar-phased arrays are analyzed. The obtained simple formulas for rms pointing errors are applicable to uniform planar arrays with both uniform and Gaussian uncorrelated phase-error distributions and for any arbitrary scan angle.

  20. Evaluation of gadolinium compounds potentially suitable for magnetic resonance using Gd-153 scintigraphy

    SciTech Connect

    Engelstad, B.; Huberty, J.; White, D.; Wynne, C.; Ramos, E.; Goldberg, H.

    1985-05-01

    Gd-153 is not customarily considered for scintigraphy, yet it: 1) is available at acceptable cost, 2) has a 242 day half-life suitable for prolonged animal studies and 3) has 97 keV (40%) and 103 keV (59%) photopeaks suitable for conventional scintigraphy. Gd-153 (10-15 ..mu..Ci; 370-555 kBq) was administered to normal rats in 5 forms: 1) carrier 0.1 mmole/kg Gd-EIDA (diethyl iminodiacetic acid), 2) tracer (<.1 umole/kg) Gd-EIDA, 3) tracer Gd-ISIDA (diisopropyl iminodiacetic acid), 4) tracer GdCl/sub 3/, and 5) tracer Gd-DTPA. Scintigraphy, performed continuously for 90 minutes following intravenous injection and at intervals at up to 2 weeks, depicted: 1) rapid, partial hepatobiliary and renal clearance of tracer Gd-EIDA and Gd-ISIDA; 2) slow blood clearance and partial hepatobiliary clearance of carrier Gd-EIDA; and 3) prolonged reticuloendothelial retention of all IDA complexes, similar to GdCl3. Whole body and tissue distribution data paralleled the scintigraphic findings. Gd-153 scintigraphy provides a simple method to assess balance, distribution, kinetics, and stability of new paramagnetic contrast agents, and bis-iminodiacetate gadolinium complexes, unlike technetium analogues, lack effective stability to prevent gadolinium hydrolysis or translocation.