Sample records for plane high tibial

  1. The effect of plate position and size on tibial slope in high tibial osteotomy: a cadaveric study.

    PubMed

    Rubino, L Joseph; Schoderbek, Robert J; Golish, S Raymond; Baumfeld, Joshua; Miller, Mark D

    2008-01-01

    Opening wedge high tibial osteotomies are performed for degenerative changes and varus. Opening wedge osteotomies can change proximal tibial slope in the sagittal plane, possibly imparting stability in the ACL-deficient knee. The aim of this study was to assess the effect of plate position and size on change in tibial slope. Eight cadaveric knees underwent opening wedge high tibial osteotomy with Puddu plates of each different size. Plates were placed anterior, central, and posterior for each size used. Lateral radiographs were obtained. Tibial slope was measured and compared with baseline slope. Tibial slope was affected by plate position (P < 0.05) and size (P < 0.001). Smaller, posterior plates had less effect on tibial slope. However, anterior and central plates increased tibial slope over all plate sizes (P < 0.05). This study found that tibial slope increases with opening wedge high tibial osteotomy. Larger corrections and anterior placement of the plate are associated with larger increases in slope.

  2. Tibial lengthening using a humeral intramedullary nail combined with a single-plane external fixator for leg discrepancy in sequelae of poliomyelitis.

    PubMed

    Chen, Daoyun; Chen, Jianmin; Liu, Fanggang; Jiang, Yao

    2011-03-01

    The sequelae of poliomyelitis are the common causes of leg discrepancy. Tibial lengthening is an effective way to solve this problem but it is associated with a high rate of complications. In this study, we combined the use of humeral nail and external fixator in tibial lengthening with the purpose of reducing lengthening complications. Compared with the cases lengthened by a single-plane external fixator alone, this combined strategy was found to be beneficial in maintaining the tibial alignment. Therefore, it can be recommended as a good technique for tibial lengthening in patients with sequelae of poliomyelitis.

  3. Minimizing Alteration of Posterior Tibial Slope During Opening Wedge High Tibial Osteotomy: a Protocol with Experimental Validation in Paired Cadaveric Knees

    PubMed Central

    Westermann, Robert W; DeBerardino, Thomas; Amendola, Annunziato

    2014-01-01

    Introduction The High Tibial Osteotomy (HTO) is a reliable procedure in addressing uni- compartmental arthritis with associated coronal deformities. With osteotomy of the proximal tibia, there is a risk of altering the tibial slope in the sagittal plane. Surgical techniques continue to evolve with trends towards procedure reproducibility and simplification. We evaluated a modification of the Arthrex iBalance technique in 18 paired cadaveric knees with the goals of maintaining sagittal slope, increasing procedure efficiency, and decreasing use of intraoperative fluoroscopy. Methods Nine paired cadaveric knees (18 legs) underwent iBalance medial opening wedge high tibial osteotomies. In each pair, the right knee underwent an HTO using the modified technique, while all left knees underwent the traditional technique. Independent observers evaluated postoperative factors including tibial slope, placement of hinge pin, and implant placement. Specimens were then dissected to evaluate for any gross muscle, nerve or vessel injury. Results Changes to posterior tibial slope were similar using each technique. The change in slope in traditional iBalance technique was -0.3° ±2.3° and change in tibial slope using the modified iBalance technique was -0.4° ±2.3° (p=0.29). Furthermore, we detected no differences in posterior tibial slope between preoperative and postoperative specimens (p=0.74 traditional, p=0.75 modified). No differences in implant placement were detected between traditional and modified techniques. (p=0.85). No intraoperative iatrogenic complications (i.e. lateral cortex fracture, blood vessel or nerve injury) were observed in either group after gross dissection. Discussion & Conclusions Alterations in posterior tibial slope are associated with HTOs. Both traditional and modified iBalance techniques appear reliable in coronal plane corrections without changing posterior tibial slope. The present modification of the Arthrex iBalance technique may increase the

  4. Posterior tibial slope in medial opening-wedge high tibial osteotomy: 2-D versus 3-D navigation.

    PubMed

    Yim, Ji Hyeon; Seon, Jong Keun; Song, Eun Kyoo

    2012-10-01

    Although opening-wedge high tibial osteotomy (HTO) is used to correct deformities, it can simultaneously alter tibial slope in the sagittal plane because of the triangular configuration of the proximal tibia, and this undesired change in tibial slope can influence knee kinematics, stability, and joint contact pressure. Therefore, medial opening-wedge HTO is a technically demanding procedure despite the use of 2-dimensional (2-D) navigation. The authors evaluated the posterior tibial slope pre- and postoperatively in patients who underwent navigation-assisted opening-wedge HTO and compared posterior slope changes for 2-D and 3-dimensional (3-D) navigation versions. Patients were randomly divided into 2 groups based on the navigation system used: group A (2-D guidance for coronal alignment; 17 patients) and group B (3-D guidance for coronal and sagittal alignments; 17 patients). Postoperatively, the mechanical axis was corrected to a mean valgus of 2.81° (range, 1°-5.4°) in group A and 3.15° (range, 1.5°-5.6°) in group B. A significant intergroup difference existed for the amount of posterior tibial slope change (Δ slope) pre- and postoperatively (P=.04).Opening-wedge HTO using navigation offers accurate alignment of the lower limb. In particular, the use of 3-D navigation results in significantly less change in the posterior tibial slope postoperatively than does the use of 2-D navigation. Accordingly, the authors recommend the use of 3-D navigation systems because they provide real-time intraoperative information about coronal, sagittal, and transverse axes and guide the maintenance of the native posterior tibial slope. Copyright 2012, SLACK Incorporated.

  5. The Effect of Sagittal Plane Deformities after Tibial Plateau Fractures to Functions and Instability of Knee Joint.

    PubMed

    Erdil, M; Yildiz, F; Kuyucu, E; Sayar, Ş; Polat, G; Ceylan, H H; Koçyiğit, F

    2016-01-01

    The objective of this study is to evaluate the effect of posterior tibial slope after fracture healing on antero-posterior knee laxity, functional outcome and patient satisfaction. 126 patients who were treated for tibial plateau fractures between 2008-2013 in the orthopedics and traumatology department of our institution were evaluated for the study. Patients were treated with open reduction and internal fixation, arthroscopy assisted minimally invasive osteosynthesis or conservative treatment. Mean posterior tibial slope after the treatment was 6.91 ± 5.11 and there was no significant difference when compared to the uninvolved side 6.42 ± 4,21 (p = 0.794). Knee laxity in anterior-posterior plane was 6.14 ± 2.11 and 5.95 ± 2.25 respectively on healthy and injured side. The difference of mean laxity in anterior-posterior plane between two sides was statistically significant. In this study we found no difference in laxity between the injured and healthy knees. However Tegner score decreased significantly in patients who had greater laxity difference between the knees. We did not find significant difference between fracture type and laxity, IKDC functional scores independent of the ligamentous injury. In conclusion despite coronal alignment is taken into consideration in treatment of tibial plateau fractures, sagittal alignment is reasonably important for stability and should not be ignored.

  6. What are the bias, imprecision, and limits of agreement for finding the flexion-extension plane of the knee with five tibial reference lines?

    PubMed

    Brar, Abheetinder S; Howell, Stephen M; Hull, Maury L

    2016-06-01

    Internal-external (I-E) malrotation of the tibial component is associated with poor function after total knee arthroplasty (TKA). Kinematically aligned (KA) TKA uses a functionally defined flexion-extension (F-E) tibial reference line, which is parallel to the F-E plane of the extended knee, to set I-E rotation of the tibial component. Sixty-two, three-dimensional bone models of normal knees were analyzed. We computed the bias (mean), imprecision (±standard deviation), and limits of agreement (mean±2 standard deviations) of the angle between five anatomically defined tibial reference lines used in mechanically aligned (MA) TKA and the F-E tibial reference line (+external). The following are the bias, imprecision, and limits of agreement of the angle between the F-E tibial reference line and 1) the tibial reference lines connecting the medial border (-2°±6°, -14° to 10°), medial 1/3 (6°±6°, -6° to 18°), and the most anterior point of the tibial tubercle (9°±4°, -1° to 17°) with the center of the posterior cruciate ligament, and 2) the tibial reference lines perpendicular to the posterior condylar axis of the tibia (-3°±4°, -11° to 5°), and a line connecting the centers of the tibial condyles (1°±4°, -7° to 9°). Based on these in vitro findings, it might be prudent to reconsider setting the I-E rotation of the tibial component to tibial reference lines that have bias, imprecision, and limits of agreement that fall outside the -7° to 10° range associated with high function after KA TKA. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Role of high tibial osteotomy in chronic injuries of posterior cruciate ligament and posterolateral corner.

    PubMed

    Savarese, Eugenio; Bisicchia, Salvatore; Romeo, Rocco; Amendola, Annunziato

    2011-03-01

    High tibial osteotomy (HTO) is a surgical procedure used to change the mechanical weight-bearing axis and alter the loads carried through the knee. Conventional indications for HTO are medial compartment osteoarthritis and varus malalignment of the knee causing pain and dysfunction. Traditionally, knee instability associated with varus thrust has been considered a contraindication. However, today the indications include patients with chronic ligament deficiencies and malalignment, because an HTO procedure can change not only the coronal but also the sagittal plane of the knee. The sagittal plane has generally been ignored in HTO literature, but its modification has a significant impact on biomechanics and joint stability. Indeed, decreased posterior tibial slope causes posterior tibia translation and helps the anterior cruciate ligament (ACL)-deficient knee. Vice versa, increased tibial slope causes anterior tibia translation and helps the posterior cruciate ligament (PCL)-deficient knee. A review of literature shows that soft tissue procedures alone are often unsatisfactory for chronic posterior instability if alignment is not corrected. Since limb alignment is the most important factor to consider in lower limb reconstructive surgery, diagnosis and treatment of limb malalignment should not be ignored in management of chronic ligamentous instabilities. This paper reviews the effects of chronic posterior instability and tibial slope alteration on knee and soft tissues, in addition to planning and surgical technique for chronic posterior and posterolateral instability with HTO.

  8. Kinematically aligned total knee arthroplasty limits high tibial forces, differences in tibial forces between compartments, and abnormal tibial contact kinematics during passive flexion.

    PubMed

    Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-06-01

    Following total knee arthroplasty (TKA), high tibial forces, large differences in tibial forces between the medial and lateral compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion indicate abnormal knee function. Because the goal of kinematically aligned TKA is to restore native knee function without soft tissue release, the objectives were to determine how well kinematically aligned TKA limits high tibial forces, differences in tibial forces between compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion. Using cruciate retaining components, kinematically aligned TKA was performed on thirteen human cadaveric knee specimens with use of manual instruments without soft tissue release. The tibial forces and tibial contact locations were measured in both the medial and lateral compartments from 0° to 120° of passive flexion using a custom tibial force sensor. The average total tibial force (i.e. sum of medial + lateral) ranged from 5 to 116 N. The only significant average differences in tibial force between compartments occurred at 0° of flexion (29 N, p = 0.0008). The contact locations in both compartments translated posteriorly in all thirteen kinematically aligned TKAs by an average of 14 mm (p < 0.0001) and 18 mm (p < 0.0001) in the medial and lateral compartments, respectively, from 0° to 120° of flexion. After kinematically aligned TKA, average total tibial forces due to the soft tissue restraints were limited to 116 N, average differences in tibial forces between compartments were limited to 29 N, and a net posterior translation of the tibial contact locations was observed in all kinematically aligned TKAs during passive flexion from 0° to 120°, which are similar to what has been measured previously in native knees. While confirmation in vivo is warranted, these findings give

  9. High tibial osteotomy in knee laxities: Concepts review and results

    PubMed Central

    Robin, Jonathan G.; Neyret, Philippe

    2016-01-01

    Patients with unstable, malaligned knees often present a challenging management scenario, and careful attention must be paid to the clinical history and examination to determine the priorities of treatment. Isolated knee instability treated with ligament reconstruction and isolated knee malalignment treated with periarticular osteotomy have both been well studied in the past. More recently, the effects of high tibial osteotomy on knee instability have been studied. Lateral closing-wedge high tibial osteotomy tends to reduce the posterior tibial slope, which has a stabilising effect on anterior tibial instability that occurs with ACL deficiency. Medial opening-wedge high tibial osteotomy tends to increase the posterior tibia slope, which has a stabilising effect in posterior tibial instability that occurs with PCL deficiency. Overall results from recent studies indicate that there is a role for combined ligament reconstruction and periarticular knee osteotomy. The use of high tibial osteotomy has been able to extend the indication for ligament reconstruction which, when combined, may ultimately halt the evolution of arthritis and preserve their natural knee joint for a longer period of time. Cite this article: Robin JG, Neyret P. High tibial osteotomy in knee laxities: Concepts review and results. EFORT Open Rev 2016;1:3-11. doi: 10.1302/2058-5241.1.000001. PMID:28461908

  10. Posterior Tibial Slope Angle Correlates With Peak Sagittal and Frontal Plane Knee Joint Loading During Robotic Simulations of Athletic Tasks.

    PubMed

    Bates, Nathaniel A; Nesbitt, Rebecca J; Shearn, Jason T; Myer, Gregory D; Hewett, Timothy E

    2016-07-01

    Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Descriptive laboratory study. A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, -7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. The mean (±SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60-0.65), flexion (r = 0.64-0.66), lateral (r = 0.57-0.69), and external rotation torques (r = 0.47-0.72) as well as inverse correlations with peak abduction (r = -0.42 to -0.61) and internal rotation torques (r = -0.39 to -0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64-0.69) and lateral knee force (r = 0.55-0.74) as well as inverse correlations with peak external torque (r = -0.34 to -0.67) and medial knee force (r = -0.58 to -0.59). These moderate correlations were also present during simulated sidestep cutting. The investigation supported the theory that increased posterior tibial slope would lead to greater magnitude knee joint moments, specifically

  11. Analysis of Knee Joint Line Obliquity after High Tibial Osteotomy.

    PubMed

    Oh, Kwang-Jun; Ko, Young Bong; Bae, Ji Hoon; Yoon, Suk Tae; Kim, Jae Gyoon

    2016-11-01

    The aim of this study was to evaluate which lower extremity alignment (knee and ankle joint) parameters affect knee joint line obliquity (KJLO) in the coronal plane after open wedge high tibial osteotomy (OWHTO). Overall, 69 knees of patients that underwent OWHTO were evaluated using radiographs obtained preoperatively and from 6 weeks to 3 months postoperatively. We measured multiple parameters of knee and ankle joint alignment (hip-knee-ankle angle [HKA], joint line height [JLH], posterior tibial slope [PS], femoral condyle-tibial plateau angle [FCTP], medial proximal tibial angle [MPTA], mechanical lateral distal femoral angle [mLDFA], KJLO, talar tilt angle [TTA], ankle joint obliquity [AJO], and the lateral distal tibial ground surface angle [LDTGA]; preoperative [-pre], postoperative [-post], and the difference between -pre and -post values [-Δ]). We categorized patients into two groups according to the KJLO-post value (the normal group [within ± 4 degrees, 56 knees] and the abnormal group [greater than ± 4 degrees, 13 knees]), and compared their -pre parameters. Multiple logistic regression analysis was used to examine the contribution of the -pre parameters to abnormal KJLO-post. The mean HKA-Δ (-9.4 ± 4.7 degrees) was larger than the mean KJLO-Δ (-2.1 ± 3.2 degrees). The knee joint alignment parameters (the HKA-pre, FCTP-pre) differed significantly between the two groups ( p  < 0.05). In addition, the HKA-pre (odds ratio [OR] = 1.27, p  = 0.006) and FCTP-pre (OR = 2.13, p  = 0.006) were significant predictors of abnormal KJLO-post. However, -pre ankle joint parameters (TTA, AJO, and LDTGA) did not differ significantly between the two groups and were not significantly associated with the abnormal KJLO-post. The -pre knee joint alignment and knee joint convergence angle evaluated by HKA-pre and FCTP-pre angle, respectively, were significant predictors of abnormal KJLO after OWHTO. However, -pre ankle joint

  12. Outcome reporting following navigated high tibial osteotomy of the knee: a systematic review.

    PubMed

    Yan, James; Musahl, Volker; Kay, Jeffrey; Khan, Moin; Simunovic, Nicole; Ayeni, Olufemi R

    2016-11-01

    This systematic review evaluates radiographic and clinical outcome reporting following navigated high tibial osteotomy (HTO). Conventional HTO was used as a control to compare outcomes and furthermore investigate the quality of evidence in studies reporting outcomes for navigated HTO. It was hypothesized that navigated HTO will show superior clinical and radiographic outcomes compared to conventional HTO. Two independent reviewers searched PubMed, Ovid (MEDLINE), EMBASE, and Cochrane databases for studies reporting outcomes following navigated HTO. Titles, abstracts, and full-text were screened in duplicate using an a priori inclusion and exclusion criteria. Descriptive statistics were calculated using Minitab ® statistical software. Methodological Index for Nonrandomized Studies (MINORS) and Cochrane Risk of Bias Scores were used to evaluate methodological quality. Thirty-four studies which involved 2216 HTOs were analysed in this review, 1608 (72.6 %) navigated HTOs and 608 (27.4 %) conventional HTOs. The majority of studies were of level IV evidence (16). Clinical outcomes were reported in knee and function scores or range of motion comparisons. Postoperative clinical and functional scores were improved by navigated HTO although it is not demonstrated if there is significant improvement compared to conventional HTO. Most common clinical outcome score reported was Lysholm scores (6) which report postoperative scores of 87.8 (standard deviation 5.9) and 88.8 (standard deviation 5.9) for conventional and navigation-assisted HTO, respectively. Radiographic outcomes reported commonly were weight-bearing mechanical axis, coronal plane angle, and posterior tibial slope angle in the sagittal plane. Studies have shown HTO gives significant correction of mechanical alignment and navigated HTO produces significantly less change in posterior tibial slope postoperatively compared to conventional. The mean MINORS for the 17 non-comparative studies was 9/16, and 15/24 for

  13. Surgical anatomy of medial open-wedge high tibial osteotomy: crucial steps and pitfalls.

    PubMed

    Madry, Henning; Goebel, Lars; Hoffmann, Alexander; Dück, Klaus; Gerich, Torsten; Seil, Romain; Tschernig, Thomas; Pape, Dietrich

    2017-12-01

    To give an overview of the basic knowledge of the functional surgical anatomy of the proximal lower leg and the popliteal region relevant to medial high tibial osteotomy (HTO) as key anatomical structures in spatial relation to the popliteal region and the proximal tibiofibular joint are usually not directly visible and thus escape a direct inspection. The surgical anatomy of the human proximal lower leg and its relevance for HTO are illustrated with a special emphasis on the individual steps of the operation involving creation of the osteotomy planes and plate fixation. The posteriorly located popliteal neurovascular bundle, but also lateral structures such as the peroneal nerve, the head of the fibula and the lateral collateral ligament must be protected from the instruments used for osteotomy. Neither positioning the knee joint in flexion, nor the posterior thin muscle layer of the popliteal muscle offers adequate protection of the popliteal neurovascular bundle when performing the osteotomy. Tactile feedback through a loss-of-resistance when the opposite cortex is perforated is only possible when sawing and drilling is performed in a pounding fashion. Kirschner wires with a proximal thread, therefore, always need to be introduced under fluoroscopic control. Due to anatomy of the tibial head, the tibial slope may increase inadvertently. Enhanced surgical knowledge of anatomical structures that are at a potential risk during the different steps of osteotomy or plate fixation will help to avoid possible injuries. Expert opinion, Level V.

  14. Bone stress in runners with tibial stress fracture.

    PubMed

    Meardon, Stacey A; Willson, John D; Gries, Samantha R; Kernozek, Thomas W; Derrick, Timothy R

    2015-11-01

    Combinations of smaller bone geometry and greater applied loads may contribute to tibial stress fracture. We examined tibial bone stress, accounting for geometry and applied loads, in runners with stress fracture. 23 runners with a history of tibial stress fracture & 23 matched controls ran over a force platform while 3-D kinematic and kinetic data were collected. An elliptical model of the distal 1/3 tibia cross section was used to estimate stress at 4 locations (anterior, posterior, medial and lateral). Inner and outer radii for the model were obtained from 2 planar x-ray images. Bone stress differences were assessed using two-factor ANOVA (α=0.05). Key contributors to observed stress differences between groups were examined using stepwise regression. Runners with tibial stress fracture experienced greater anterior tension and posterior compression at the distal tibia. Location, but not group, differences in shear stress were observed. Stepwise regression revealed that anterior-posterior outer diameter of the tibia and the sagittal plane bending moment explained >80% of the variance in anterior and posterior bone stress. Runners with tibial stress fracture displayed greater stress anteriorly and posteriorly at the distal tibia. Elevated tibial stress was associated with smaller bone geometry and greater bending moments about the medial-lateral axis of the tibia. Future research needs to identify key running mechanics associated with the sagittal plane bending moment at the distal tibia as well as to identify ways to improve bone geometry in runners in order to better guide preventative and rehabilitative efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. A modified technique to reduce tibial keel cutting errors during an Oxford unicompartmental knee arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Tahara, Keitarou; Yamagami, Ryota; Sanada, Takaki; Tanaka, Sakae

    2017-03-01

    Bone cutting errors can cause malalignment of unicompartmental knee arthroplasties (UKA). Although the extent of tibial malalignment due to horizontal cutting errors has been well reported, there is a lack of studies evaluating malalignment as a consequence of keel cutting errors, particularly in the Oxford UKA. The purpose of this study was to examine keel cutting errors during Oxford UKA placement using a navigation system and to clarify whether two different tibial keel cutting techniques would have different error rates. The alignment of the tibial cut surface after a horizontal osteotomy and the surface of the tibial trial component was measured with a navigation system. Cutting error was defined as the angular difference between these measurements. The following two techniques were used: the standard "pushing" technique in 83 patients (group P) and a modified "dolphin" technique in 41 patients (group D). In all 123 patients studied, the mean absolute keel cutting error was 1.7° and 1.4° in the coronal and sagittal planes, respectively. In group P, there were 22 outlier patients (27 %) in the coronal plane and 13 (16 %) in the sagittal plane. Group D had three outlier patients (8 %) in the coronal plane and none (0 %) in the sagittal plane. Significant differences were observed in the outlier ratio of these techniques in both the sagittal (P = 0.014) and coronal (P = 0.008) planes. Our study demonstrated overall keel cutting errors of 1.7° in the coronal plane and 1.4° in the sagittal plane. The "dolphin" technique was found to significantly reduce keel cutting errors on the tibial side. This technique will be useful for accurate component positioning and therefore improve the longevity of Oxford UKAs. Retrospective comparative study, Level III.

  16. Detecting condylar contact loss using single-plane fluoroscopy: a comparison with in vivo force data and in vitro bi-plane data.

    PubMed

    Prins, A H; Kaptein, B L; Banks, S A; Stoel, B C; Nelissen, R G H H; Valstar, E R

    2014-05-07

    Knee contact mechanics play an important role in knee implant failure and wear mechanics. Femoral condylar contact loss in total knee arthroplasty has been reported in some studies and it is considered to potentially induce excessive wear of the polyethylene insert.Measuring in vivo forces applied to the tibial plateau with an instrumented prosthesis is a possible approach to assess contact loss in vivo, but this approach is not very practical. Alternatively, single-plane fluoroscopy and pose estimation can be used to derive the relative pose of the femoral component with respect to the tibial plateau and estimate the distance from the medial and lateral parts of the femoral component towards the insert. Two measures are reported in the literature: lift-off is commonly defined as the difference in distance between the medial and lateral condyles of the femoral component with respect to the tibial plateau; separation is determined by the closest distance of each condyle towards the polyethylene insert instead of the tibia plateau.In this validation study, lift-off and separation as measured with single-plane fluoroscopy are compared to in vivo contact forces measured with an instrumented knee implant. In a phantom study, lift-off and separation were compared to measurements with a high quality bi-plane measurement.The results of the in vivo contact-force experiment demonstrate a large discrepancy between single-plane fluoroscopy and the in vivo force data: single-plane fluoroscopy measured up to 5.1mm of lift-off or separation, whereas the force data never showed actual loss of contact. The phantom study demonstrated that the single-plane setup could introduce an overestimation of 0.22mm±±0.36mm. Correcting the out-of-plane position resulted in an underestimation of medial separation by -0.20mm±±0.29mm.In conclusion, there is a discrepancy between the in vivo force data and single-plane fluoroscopic measurements. Therefore contact loss may not always be

  17. Total knee arthroplasty after high tibial osteotomy. A comparison study in patients who had bilateral total knee replacement.

    PubMed

    Meding, J B; Keating, E M; Ritter, M A; Faris, P M

    2000-09-01

    The outcome of total knee replacement after high tibial osteotomy remains uncertain. We hypothesized that the results of total knee replacement with or without a previous high tibial osteotomy are similar. The results of a consecutive series of thirty-nine bilateral total knee arthroplasties performed with cement at an average of 8.7 years after unilateral high tibial osteotomy were reviewed. There were twenty-seven men and twelve women. Preoperatively, the knee scores according to the system of the Knee Society were similar for all of the knees; however, valgus alignment and patella infera were more common in the knees with a previous high tibial osteotomy. Bilateral total knee replacement was staged in seven patients and was simultaneous in thirty-two patients. The results of the total knee arthroplasties were retrospectively reviewed with respect to the knee and function scores according to the system of the Knee Society, the radiographic findings, and the complications. Intraoperatively, no notable differences were identified in the number of medial, lateral, or lateral patellar releases required. However, less lateral tibial bone was resected in the group with a previous high tibial osteotomy (average, 3.3 millimeters) than in the group without a high tibial osteotomy (average, 7.5 millimeters). The average duration of follow-up was 7.5 years (range, three to sixteen years) in the group with a previous high tibial osteotomy and 6.8 years (range, two to ten years) in the group without a high tibial osteotomy. At the time of the final follow-up, the knee and function scores were similar for the two groups (89.0 and 81.0 points, respectively, for the group with a previous high tibial osteotomy, and 89.6 and 83.9 points, respectively, for the group without a high tibial osteotomy). Although more knees were free of pain in the group without a previous high tibial osteotomy (thirty-six) than in the group with a previous osteotomy (thirty-three), this difference was

  18. Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study.

    PubMed

    Munier, M; Donnez, M; Ollivier, M; Flecher, X; Chabrand, P; Argenson, J-N; Parratte, S

    2017-04-01

    Treatment of medial tibiofemoral osteoarthritis with a high-tibial osteotomy (HTO) is most effective when the optimal angular correction is achieved. However, conventional instrumentation is limited when multiplanar correction is needed. Use of patient-specific cutting guides (PSCGs) for HTO provides an accurate correction (difference<2°) relative to the preoperative planning. Between February 2014 and February 2015, 10 patients (mean age: 46 years [range: 31-59]; grade 1 or 2 osteoarthritis in Ahlbäck's classification) were included prospectively in this reliability and safety study. All patients were operated using the same medial opening-wedge osteotomy technique. Preoperative planning was based on long-leg radiographs and CT scans with 3D reconstruction. The PSGCs were used to align the osteotomy cut and position the screw holes for the plate. The desired correction was achieved in the three planes when the holes on the plate were aligned with the holes drilled based on the PSCG. Preoperatively, the mean HKA angle was 171.9° (range: 166-179°), the mean proximal tibial angle was 87° (86-88°) and the mean tibial slope was 7.8° (1-22°). The postoperative correction was compared to the planned correction using 3D CT scan transformations. Intraoperative and postoperative complications were assessed at a minimum follow-up of 1 year. The procedure was successfully carried out in all patients with the PSCGs. On postoperative long-leg radiographs, the mean HKA was 182.3° (180-185°); on the CT scan, the mean tibial mechanical angle was 94° (90-98°) and the mean tibial slope was 7.1° (4-11°). In 19 out of 20 postoperative HKA and slope measurements, the difference between the planned and achieved correction was <2° based on the 3D analysis of the three planes in space; in the other case, the slope was 13° instead of the planned 10°. The intra-class correlation coefficients between the postoperative and planned parameters were 0.98 [0.92-0.99] for

  19. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    PubMed

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  20. High-resolution axial MR imaging of tibial stress injuries

    PubMed Central

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  1. Histological Analysis of the Tibial Anterior Cruciate Ligament Insertion

    PubMed Central

    Siebold, Rainer; Oka, Shinya; Traut, Ulrike; Schuhmacher, Peter; Kirsch, Joachim

    2017-01-01

    Objective: To describe the morphology of the tibial ACL insertion by histological assessment in the sagittal plane. Methods: For histology the native (undissected) tibial ACL insertion of 6 fresh-frozen cadaveric knees was cut into 4 sagittal sections parallel to the long axis of the medial tibial spine. The slices were stained with hematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analyzed at a magnification of ×20. Results: From medial to lateral the anterior-posterior lengths of the ACL insertion were an average of 10.2, 9.3, 7.6 and 5.8 mm. The anterior margin of the tibial ACL insertion raised from an anterior ridge. The most medial ACL fibers rose along with a peak of the anterior part of the medial tibial spine in which the direct insertion was adjacent to the articular cartilage. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact to the lateral ACL insertion. A small fat pad was located just posterior to the tibial ACL insertion. There were no central or posterolateral inserting ACL fibers in the area intercondylaris anterior. Conclusion: The functional intraligamentous midsubstance ACL fibers arose from the most posterior part of its bony tibial insertion in a flat and “C-shape” way. The anterior border of this functional ACL started from a bony ‘anterior ridge’ and the medial border was along with a peak of the medial tibial spine.

  2. High resolution ultrasonography of the tibial nerve in diabetic peripheral neuropathy.

    PubMed

    Singh, Kunwarpal; Gupta, Kamlesh; Kaur, Sukhdeep

    2017-12-01

    High-resolution ultrasonography of the tibial nerve is a fast and non invasive tool for diagnosis of diabetic peripheral neuropathy. Our study was aimed at finding out the correlation of the cross sectional area and maximum thickness of nerve fascicles of the tibial nerve with the presence and severity of diabetic peripheral neuropathy. 75 patients with type 2 diabetes mellitus clinically diagnosed with diabetic peripheral neuropathy were analysed, and the severity of neuropathy was determined using the Toronto Clinical Neuropathy Score. 58 diabetic patients with no clinical suspicion of diabetic peripheral neuropathy and 75 healthy non-diabetic subjects were taken as controls. The cross sectional area and maximum thickness of nerve fascicles of the tibial nerves were calculated 3 cm cranial to the medial malleolus in both lower limbs. The mean cross sectional area (22.63 +/- 2.66 mm 2 ) and maximum thickness of nerve fascicles (0.70 mm) of the tibial nerves in patients with diabetic peripheral neuropathy compared with both control groups was significantly larger, and statistically significant correlation was found with the Toronto Clinical Neuropathy Score ( p < 0.001). The diabetic patients with no signs of peripheral neuropathy had a larger mean cross sectional area (14.40 +/- 1.72 mm 2 ) and maximum thickness of nerve fascicles of the tibial nerve (0.40 mm) than healthy non-diabetic subjects (12.42 +/- 1.01 mm 2 and 0.30 mm respectively). The cross sectional area and maximum thickness of nerve fascicles of the tibial nerve is larger in diabetic patients with or without peripheral neuropathy than in healthy control subjects, and ultrasonography can be used as a good screening tool in these patients.

  3. Femoro-tibial kinematics after TKA in fixed- and mobile-bearing knees in the sagittal plane.

    PubMed

    Daniilidis, Kiriakos; Höll, Steffen; Gosheger, Georg; Dieckmann, Ralf; Martinelli, Nicolo; Ostermeier, Sven; Tibesku, Carsten O

    2013-10-01

    Lack of the anterior cruciate ligament in total knee arthroplasty results in paradoxical movement of the femur as opposed to the tibia under deep flexion. Total knee arthroplasty with mobile-bearing inlays has been developed to provide increased physiological movement of the knee joint and to reduce polyethylene abrasion. The aim of this study was to perform an in vitro analysis of the kinematic movement in the sagittal plane in order to show differences between fixed- and mobile-bearing TKA in comparison with the natural knee joint. Seven knee joints of human cadaver material were used in a laboratory experiment. Fixed- and mobile-bearing inlays were tested in sequences under isokinetic extension in so-called kinemator for knee joints, which can simulate muscular traction power by the use of hydraulic cylinders, which crossover the knee joint. As a target parameter, the a.p. translation of the tibio-femoral relative movement was measured in the sagittal plane under ultrasound (Zebris) control. The results show a reduced tibial a.p. translation in relation to the femur in the bearing group compared to the natural joint. In the Z-axis, between 110° and 50° of flexion, linear movement decreases towards caudal movement under extension. Admittedly, the study did not show differences in the movement pattern between "mobile-bearing" and "fixed-bearing" prostheses. Results of this study cannot prove functional advantages of mobile-bearing prostheses for the knee joint kinematic after TKA. Both types of prostheses show typical kinematics of an anterior instability, hence they were incapable of performing physiological movement.

  4. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    PubMed

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile

  5. Open wedge high tibial osteotomy using three-dimensional printed models: Experimental analysis using porcine bone.

    PubMed

    Kwun, Jun-Dae; Kim, Hee-June; Park, Jaeyoung; Park, Il-Hyung; Kyung, Hee-Soo

    2017-01-01

    The purpose of this study was to evaluate the usefulness of three-dimensional (3D) printed models for open wedge high tibial osteotomy (HTO) in porcine bone. Computed tomography (CT) images were obtained from 10 porcine knees and 3D imaging was planned using the 3D-Slicer program. The osteotomy line was drawn from the three centimeters below the medial tibial plateau to the proximal end of the fibular head. Then the osteotomy gap was opened until the mechanical axis line was 62.5% from the medial border along the width of the tibial plateau, maintaining the posterior tibial slope angle. The wedge-shaped 3D-printed model was designed with the measured angle and osteotomy section and was produced by the 3D printer. The open wedge HTO surgery was reproduced in porcine bone using the 3D-printed model and the osteotomy site was fixed with a plate. Accuracy of osteotomy and posterior tibial slope was evaluated after the osteotomy. The mean mechanical axis line on the tibial plateau was 61.8±1.5% from the medial tibia. There was no statistically significant difference (P=0.160). The planned and post-osteotomy correction wedge angles were 11.5±3.2° and 11.4±3.3°, and the posterior tibial slope angle was 11.2±2.2° pre-osteotomy and 11.4±2.5° post-osteotomy. There were no significant differences (P=0.854 and P=0.429, respectively). This study showed that good results could be obtained in high tibial osteotomy by using 3D printed models of porcine legs. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. The effect of high tibial osteotomy on osteoarthritis of the knee : Clinical and histological observations.

    PubMed

    Koshino, T; Tsuchiya, K

    1979-03-01

    High tibial osteotomies were performed on 136 osteoarthritic knees for correction of varus deformity. Before osteotomy all patients experienced moderate or severe pain, and the knees showed lateral thrust on weight-bearing. The patients were followed up for one to five years. Marked relief of pain was obtained in 112 knees, and the patients were satisfied with the result of operation in 122. These painless knees showed no lateral thrust, and in the majority the deformity had been adequately corrected, with post-operative femoro-tibial angles (standing) ranging from 165° to 174°. Four of 28 knees with femoro-tibial angles of 175° to 179°, when measured one year after operation, showed recurrence of varus deformity three years after osteotomy. Preoperative ranges of knee motion were well maintained after osteotomy even when arthrotomy had also been undertaken. Intra-articular assessment in two patients, several years after operation, showed that the most degenerated portions of the articular surface were completely covered by a fibrocartilagenous layer, with no bare bone.High tibial osteotomy is most effective in osteoarthritic knees with varus deformity, when correction is made to a femoro-tibial angle (standing) of 170° (10° valgus).

  7. The effect of high tibial osteotomy on osteoarthritis of the knee. Clinical and histological observations.

    PubMed

    Koshino, T; Tsuchiya, K

    1979-01-01

    High tibial osteotomies were performed on 136 osteoarthritic knees for correction of varus deformity. Before osteotomy all patients experienced moderate or severe pain, and the knees showed lateral thrust on weight-bearing. The patients were followed up for one to five years. Marked relief of pain was obtained in 112 knees, and the patients were satisfied with the result of operation in 122. These painless knees showed no lateral thrust, and in the majority the deformity had been adequately corrected, with post-operative femoro-tibial angles (standing) ranging from 165 degrees to 174 degrees. Four of 28 knees with femoro-tibial angles of 175 degrees to 179 degrees, when measured one year after operation, showed recurrence of varus deformity three years after osteotomy. Preoperative ranges of knee motion were well maintained after osteotomy even when arthrotomy had also been undertaken. Intra-articular assessment in two patients, several years after operation, showed that the most degenerated portions of the articular surface were completely covered by a fibrocartilagenous layer, with no bare bone. High tibial osteotomy is most effective in osteoarthritic knees with varus deformity, when correction is made to a femoro-tibial angle (standing) of 170 degrees (10 degrees valgus).

  8. The transverse ligament as a landmark for tibial sagittal insertions of the anterior cruciate ligament: a cadaveric study.

    PubMed

    Kongcharoensombat, Wirat; Ochi, Mitsuo; Abouheif, Mohamed; Adachi, Nobuo; Ohkawa, Shingo; Kamei, Goki; Okuhara, Atushi; Shibuya, Hoyatoshi; Niimoto, Takuya; Nakasa, Tomoyuki; Nakamae, Atsuo; Deie, Masataka

    2011-10-01

    The purpose of this study was to determine the relation between the position of the transverse ligament, the anterior edge of the anterior cruciate ligament (ACL) tibial footprint, and the center of the ACL tibial insertion. We used arthroscopy for localization of the anatomic landmarks, followed by insertions of guide pins under direct visualization, and then the position of these guide pins was checked on plain lateral radiographs. The transverse ligament and the anterior aspect of the ACL tibial footprint were identified by arthroscopy in 20 unpaired cadaveric knees (10 left and 10 right). Guide pins were inserted with tibial ACL adapter drill guides under direct observation at the transverse ligament, the anterior aspect of the tibial footprint, and the center of tibial insertion of the ACL. Then, plain lateral radiographs of specimens were taken. The Amis and Jakob line was used to define the attachment of the ACL tibial insertion and the transverse ligament. A sagittal percentage of the location of the insertion point was determined and calculated from the anterior margin of the tibia in the anteroposterior direction. The transverse ligament averaged 21.20% ± 4.1%, the anterior edge of the ACL tibial insertion averaged 21.60% ± 4.0%, and the center of the ACL tibial insertion averaged 40.30% ± 4.8%. There were similar percent variations between the transverse ligament and the anterior edge of the ACL tibial insertion, with no significant difference between them (P = .38). Intraobserver and interobserver reliability was high, with small standard errors of measurement. This study shows that the transverse ligament coincides with the anterior edge of the ACL tibial footprint in the sagittal plane. The transverse ligament can be considered as a new landmark for tibial tunnel positioning during anatomic ACL reconstruction. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Improvement of the knee center of rotation during walking after opening wedge high tibial osteotomy.

    PubMed

    Kim, Kyungsoo; Feng, Jun; Nha, Kyung Wook; Park, Won Man; Kim, Yoon Hyuk

    2015-06-01

    Accurate measurement of the center of rotation of the knee joint is indispensable for prediction of joint kinematics and kinetics in musculoskeletal models. However, no study has yet identified the knee center of rotations during several daily activities before and after high tibial osteotomy surgery, which is one surgical option for treating knee osteoarthritis. In this study, an estimation method for determining the knee joint center of rotation was developed by applying the optimal common shape technique and symmetrical axis of rotation approach techniques to motion-capture data and validated for typical activities (walking, squatting, climbing up stairs, walking down stairs) of 10 normal subjects. The locations of knee joint center of rotations for injured and contralateral knees of eight subjects with osteoarthritis, both before and after high tibial osteotomy surgery, were then calculated during walking. It was shown that high tibial osteotomy surgery improved the knee joint center of rotation since the center of rotations for the injured knee after high tibial osteotomy surgery were significantly closer to those of the normal healthy population. The difference between the injured and contralateral knees was also generally reduced after surgery, demonstrating increased symmetry. These results indicate that symmetry in both knees can be recovered in many cases after high tibial osteotomy surgery. Moreover, the recovery of center of rotation in the injured knee was prior to that of symmetry. This study has the potential to provide fundamental information that can be applied to understand abnormal kinematics in patients, diagnose knee joint disease, and design a novel implants for knee joint surgeries. © IMechE 2015.

  10. [High tibial osteotomy--fixation by means of external fixation--indication, technique, complications (author's transl)].

    PubMed

    Klems, H

    1976-02-01

    High tibial osteotomy has proved its value in the treatment of gonarthrosis with or without axis deformity. The thrust of weight-bearing and other stresses is lessened on the degenerated tibial condyle and transferred to the more normal condyle. The stable fixation by means of external fixation allows early movement of the knee joint.-R-ferences to operative technique, indication, complications and after-treatment.

  11. Anthropometric measurements of tibial plateau and correlation with the current tibial implants.

    PubMed

    Erkocak, Omer Faruk; Kucukdurmaz, Fatih; Sayar, Safak; Erdil, Mehmet Emin; Ceylan, Hasan Huseyin; Tuncay, Ibrahim

    2016-09-01

    The aim of the study was to make an anthropometric analysis at the resected surfaces of the proximal tibia in the Turkish population and to compare the data with the dimensions of tibial components in current use. We hypothesized that tibial components currently available on the market do not fulfil the requirements of this population and a new tibial component design may be required, especially for female patients with small stature. Anthropometric data from the proximal tibia of 226 knees in 226 Turkish subjects were measured using magnetic resonance imaging. We measured the mediolateral, middle anteroposterior, medial and lateral anteroposterior dimensions and the aspect ratio of the resected proximal tibial surface. All morphological data were compared with the dimensions of five contemporary tibial implants, including asymmetric and symmetric design types. The dimensions of the tibial plateau of Turkish knees demonstrated significant differences according to gender (P < 0.05). Among the different tibial implants reviewed, neither asymmetric nor symmetric designs exhibited a perfect conformity to proximal tibial morphology in size and shape. The vast majority of tibial implants involved in this study tend to overhang anteroposteriorly, and a statistically significant number of women (21 %, P < 0.05) had tibial anteroposterior diameters smaller than the smallest available tibial component. Tibial components designed according to anthropometric measurements of Western populations do not perfectly meet the requirements of Turkish population. These data could provide the basis for designing the optimal and smaller tibial component for this population, especially for women, is required for best fit. II.

  12. Area of the tibial insertion site of the anterior cruciate ligament as a predictor for graft size.

    PubMed

    Guenther, Daniel; Irarrázaval, Sebastian; Albers, Marcio; Vernacchia, Cara; Irrgang, James J; Musahl, Volker; Fu, Freddie H

    2017-05-01

    To determine the distribution of different sizes of the area of the tibial insertion site among the population and to evaluate whether preoperative MRI measurements correlate with intraoperative findings to enable preoperative planning of the required graft size to cover the tibial insertion site sufficiently. The hypothesis was that the area of the tibial insertion site varies among individuals and that there is good agreement between MRI and intraoperative measurements. Intraoperative measurements of the tibial insertion site were taken on 117 patients. Three measurements were taken in each plane building a grid to cover the tibial insertion site as closely as possible. The mean of the three measurements in each plane was used for determination of the area. Two orthopaedic surgeons, who were blinded to the intraoperative measurements, took magnetic resonance imaging (MRI) measurements of the area of the tibial insertion site at two different time points. The intraoperative measured mean area was 123.8 ± 21.5 mm 2 . The mean area was 132.8 ± 15.7 mm 2 (rater 1) and 136.7 ± 15.4 mm 2 (rater 2) when determined using MRI. The size of the area was approximately normally distributed. Inter-rater (0.89; 95 % CI 0.84, 0.92; p < 0.001) and intrarater reliability (rater 1: 0.97; 95 % CI 0.95, 0.98; p < 0.001; rater 2: 0.95; 95 % CI 0.92, 0.96; p < 0.001) demonstrated excellent test-retest reliability. There was good agreement between MRI and intraoperative measurement of tibial insertion site area (ICCs rater 1: 0.80; 95 % CI 0.71, 0.87; p < 0.001; rater 2: 0.87; 95 % CI 0.81, 0.91; p < 0.001). The tibial insertion site varies in size and shape. Preoperative determination of the area using MRI is repeatable and enables planning of graft choice and size to optimally cover the tibial insertion site. III.

  13. Analysis of anatomic periarticular tibial plate fit on normal adults.

    PubMed

    Goyal, Kanu S; Skalak, Anthony S; Marcus, Randall E; Vallier, Heather A; Cooperman, Daniel R

    2007-08-01

    Implant manufacturers are producing anatomically contoured periarticular plates to improve the treatment of proximal tibia fractures. We assessed the accuracy of the designation anatomic. We applied eight-hole medial and lateral anatomically contoured periarticular plates to 101 cadaveric tibiae. The tibiae and the plate fits were mapped, quantified, and analyzed using a MicroScribe G2LX digitizer, Rhinoceros software, and MATLAB software. By corresponding the clinical appearance of good fit with our digital findings, we created numerical criteria for plate fit in three planes: coronal (volume of free space between the plate and bone), sagittal (alignment with the tibial plateau and shaft), and axial (match in curvature between the proximal horizontal part of the plate and the tibial plateau). An anatomic fit should mirror the shape of the tibia in all three planes, and only four medial and four lateral plate fits qualified. Recognizing and understanding the substantial variations in fit that exist between anatomically contoured plates and the tibia may help lead to a more stable fixation and prevent malreduction of the fracture and/or soft tissue impingement.

  14. Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques.

    PubMed

    Iorio, R; Pagnottelli, M; Vadalà, A; Giannetti, S; Di Sette, P; Papandrea, P; Conteduca, F; Ferretti, A

    2013-01-01

    The purpose of our study was to compare clinical and radiological results of two groups of patients treated for medial compartment osteoarthritis of the knee with either conventional or computer-assisted open-wedge high tibial osteotomy (HTO). Goals of surgical treatment were a correction of the mechanical axis between 2° and 6° of valgus and a modification of posterior tibial slope between -2° and +2°. Twenty-four patients (27 knees) affected by varus knee deformity and operated with HTO were prospectively followed-up. They were randomly divided in two groups, A (11 patients, conventional treatment) and B (13 patients, navigated treatment). The American Knee Society Score and the Modified Cincinnati Rating System Questionnaire were used for clinical assessment. All patients were radiologically evaluated with a comparative lower limb weight-bearing digital radiograph, a standard digital anteroposterior, a latero-lateral radiograph of the knee, and a Rosenberg view. Patients were followed-up at a mean of 39 months. Clinical evaluation showed no statistical difference (n.s.) between the two groups. Radiological results showed an 86% reproducibility in achieving a mechanical axis of 182°-186° in group B compared to a 23% in group A (p = 0.0392); furthermore, in group B, we achieved a modification of posterior tibial slope between -2° and +2° in 100% of patients, while in group A, this goal was achieved only in 24% of cases (p = 0.0021). High tibial osteotomy with navigator is more accurate and reproducible in the correction of the deformity compared to standard technique. Therapeutic study, Level II.

  15. Opening-wedge high tibial osteotomy with a locked low-profile plate: surgical technique.

    PubMed

    Kolb, Werner; Guhlmann, Hanno; Windisch, Christoph; Koller, Heiko; Grützner, Paul; Kolb, Klaus

    2010-09-01

    High tibial osteotomy has been recognized as a beneficial treatment for osteoarthritis of the medial compartment of the knee. The purpose of this prospective study was to assess the short-term results of opening-wedge high tibial osteotomies with locked plate fixation. From September 2002 to November 2005, fifty-one consecutive medial opening-wedge high tibial osteotomies were performed. The mean age of the patients at the time of the index operation was forty-nine years. The preoperative and postoperative factors analyzed included the grade of arthritis of the tibiofemoral compartment (the Ahlbäck radiographic grade), the anatomic tibiofemoral angle, patellar height, the Hospital for Special Surgery rating system score, and the Lysholm and Gillquist knee score. Postoperatively, one superficial wound infection occurred. Fifty of the fifty-one osteotomies healed after an average period of 12.9 weeks (range, eight to sixteen weeks) without bone grafts. A nonunion developed in a sixty-two-year-old patient who was a cigarette smoker. The average postoperative tibiofemoral angle was 9° of valgus. Forty-nine patients were followed for a mean of fifty-two months. The average score on the Hospital for Special Surgery rating system was 86 points at the time of the most recent follow-up. The rating was excellent in twenty-eight patients (57%), good in twelve (24%), fair in four (8%), and poor in five (10%). The average score on the Lysholm and Gillquist knee-scoring scale was 83 points. According to these scores, the outcome was excellent in nine patients (18%), good in thirty-one (63%), fair in three (6%), and poor in six (12%). Four knees failed after an average of thirty-six months. Our results suggest that an opening-wedge high tibial osteotomy with locked plate fixation allows a correct valgus angle to be achieved with good short-term results.

  16. A high rate of tibial plateau fractures after early experience with patient-specific instrumentation for unicompartmental knee arthroplasties.

    PubMed

    Leenders, A M; Schotanus, M G M; Wind, R J P; Borghans, R A P; Kort, N P

    2018-04-30

    Patient-specific instrumentation (PSI) for unicompartmental knee arthroplasty (UKA) has been available for a few years. However, limited literature is available on this subject. Hence, the aim of this cohort study is to evaluate the 2 years' results of our first experiences with the use of PSI in UKA. It is hypothesised that there is no advantage in rate of adverse events and in radiological and functional outcomes in comparison to literature on the conventional method. This cohort included 129 knees of 122 patients, operated by one surgeon. Outcome measures were the rate of adverse events (AEs); implant position as determined on radiographs; the accuracy of the default and approved planning of the implant sizes and the patient-reported outcome measures (PROMs) preoperatively, and at 3, 12 and 24 months, postoperatively. A total of 6 (4.9%) AEs were observed in this study, with 4 (3.3%) tibial fractures being the main complication. The mean postoperative biomechanical axis was 176.4° and in the majority of cases, the radiographic criteria, as determined by the manufacturer, were met. The tibial component showed 20 (16.4%) outliers in the sagittal and 3 (2.5%) outliers in the frontal plane. There were no outliers of the femoral component. For the femoral and tibial components, respectively, in 125 (96.9%) and 79 (61.7%) cases, there was an agreement between approved planning and implanted component size. All PROMs improved significantly after surgery. Tibial fracture was the most common AE, probably related to the transition from cemented to uncemented UKA. Perioperative modifications to the surgical technique were made in order to prevent this AE. Improvements should be made to the operation technique of the uncemented tibial plateau to obtain an adequate placement and at the same time reduce the risk for tibial fracture. The PSI technique was a reliable tool for the placement of the femoral component. Functional outcome was in line with literature on the

  17. Complex Medial Meniscus Tears Are Associated With a Biconcave Medial Tibial Plateau.

    PubMed

    Barber, F Alan; Getelman, Mark H; Berry, Kathy L

    2017-04-01

    To determine whether an association exists between a biconcave medial tibial plateau and complex medial meniscus tears. A consecutive series of stable knees undergoing arthroscopy were evaluated retrospectively with the use of preoperative magnetic resonance imaging (MRI), radiographs, and arthroscopy documented by intraoperative videos. Investigators independently performed blinded reviews of the MRI or videos. Based on the arthroscopy findings, medial tibial plateaus were classified as either biconcave or not biconcave. A transverse coronal plane ridge, separating the front of the tibial plateau from the back near the inner margin of the posterior body of the medial meniscus, was defined as biconcave. The medial plateau slope was calculated with MRI sagittal views. General demographic information, body mass index, and arthroscopically confirmed knee pathology were recorded. A total of 179 consecutive knees were studied from July 2014 through August 2015; 49 (27.2%) biconcave medial tibial plateaus and 130 (72.8%) controls were identified at arthroscopy. Complex medial meniscus tears were found in 103. Patients with a biconcave medial tibial plateau were found to have more complex medial meniscus tears (69.4%) than those without a biconcavity (53.1%) (P = .049) despite having lower body mass index (P = .020). No difference in medial tibial plateau slope was observed for biconcavities involving both cartilage and bone, bone only, or an indeterminate group (P = .47). Biconcave medial tibial plateaus were present in 27.4% of a consecutive series of patients undergoing knee arthroscopy. A biconcave medial tibial plateau was more frequently associated with a complex medial meniscus tear. Level III, case-control study. Copyright © 2016 Arthroscopy Association of North America. All rights reserved.

  18. Knee braces can decrease tibial rotation during pivoting that occurs in high demanding activities.

    PubMed

    Giotis, Dimitrios; Tsiaras, Vasilios; Ristanis, Stavros; Zampeli, Franceska; Mitsionis, Grigoris; Stergiou, Nicholas; Georgoulis, Anastasios D

    2011-08-01

    The purpose of this study was to investigate whether knee braces could effectively decrease tibial rotation during high demanding activities. Using an in vivo three-dimensional kinematic analysis, 21 physically active, healthy, male subjects were evaluated. Each subject performed two tasks that were used extensively in the literature because they combine increased rotational and translational loads on the knee, (1) descending from a stair and subsequent pivoting and (2) landing from a platform and subsequent pivoting under three conditions: (A) wearing a prophylactic brace (braced), (B) wearing a patellofemoral brace (sleeved), and (C) unbraced condition. In the first task, tibial rotation during the pivoting phase was significantly decreased in the braced condition as compared to the sleeved condition (P = 0.019) and the non-braced condition (P = 0.002). In the second task, the same variable was significantly decreased in the braced condition as compared to the sleeved (P = 0.001) and the unbraced condition (P < 0.001). The sleeved condition also produced significantly decreased tibial rotation with respect to the unbraced condition (P = 0.021). Bracing decreased tibial rotation in activities where increased translational and rotational forces were applied. Because knee braces decreased tibial rotation, they can possibly be used with ACL-reconstructed and ACL-deficient patients to prevent such problems. Case-control study, Level III.

  19. Effect of tibial slope on the stability of the anterior cruciate ligament-deficient knee.

    PubMed

    Voos, James E; Suero, Eduardo M; Citak, Musa; Petrigliano, Frank P; Bosscher, Marianne R F; Citak, Mustafa; Wickiewicz, Thomas L; Pearle, Andrew D

    2012-08-01

    We aimed to quantify the effect of changes in tibial slope on the magnitude of anterior tibial translation (ATT) in the anterior cruciate ligament (ACL)-deficient knee during the Lachman and mechanized pivot shift tests. We hypothesized that increased posterior tibial slope would increase the amount of ATT of an ACL-deficient knee, while leveling the slope of the tibial plateau would decrease the amount of ATT. Lachman and mechanized pivot shift tests were performed on hip-to-toe cadaveric specimens, and ATT of the lateral and the medial compartments was measured using navigation (n = 11). The ACL was then sectioned. Stability testing was repeated, and ATT was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5 or -5° of tibial slope variation after which stability testing was repeated (n = 10). Sectioning the ACL resulted in a significant increase in ATT in both the Lachman and mechanized pivot shift tests (P < 0.05). Increasing or decreasing the slope of the tibial plateau had no effect on ATT during the Lachman test (n.s.). During the mechanized pivot shift tests, a 5° increase in posterior slope resulted in a significant increase in ATT compared to the native knee (P < 0.05), while a 5° decrease in slope reduced ATT to a level similar to that of the intact knee. Tibial slope changes did not affect the magnitude of translation during a Lachman test. However, large changes in tibial slope variation affected the magnitude of the pivot shift.

  20. The distance from the extramedullary cutting guide rod to the skin surface as a reference guide for the tibial slope in total knee arthroplasty.

    PubMed

    Tsukeoka, Tadashi; Tsuneizumi, Yoshikazu

    2016-03-01

    Although sagittal tibial alignment in total knee arthroplasty (TKA) is important, no landmarks exist to achieve a reproducible slope. The purpose of this study was to evaluate the clinical usefulness of the distance from the guide rod to the skin surface for the tibial slope in TKA. Computer simulation studies were performed on 100 consecutive knees scheduled for TKA. The angle between the line connecting the most anterior point of the predicted tibial cut surface and the skin surface 20 cm distal to the predicted cut surface (Line S) and the mechanical axis (MA) of the tibia in the sagittal plane was measured. The mean (±SD) absolute angle difference between the Line S and the MA was 0.9°±0.7°. The Line S was almost parallel to the MA in the sagittal plane (95% and 99% within two degrees and three degrees of deviation from MA, respectively). The guide rod orientation is a surrogate for the tibial cut slope because the targeted posterior slope is usually built into the cutting block and ensuring the rod is parallel to the MA in the sagittal plane is recommended. Therefore the distance between the skin surface and the rod can be a useful guide for the tibial slope. II. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation.

    PubMed

    Boonen, Bert; Schotanus, Martijn G M; Kerens, Bart; Hulsmans, Frans-Jan; Tuinebreijer, Wim E; Kort, Nanne P

    2017-09-01

    To assess whether there is a significant difference between the alignment of the individual femoral and tibial components (in the frontal, sagittal and horizontal planes) as calculated pre-operatively (digital plan) and the actually achieved alignment in vivo obtained with the use of patient-specific positioning guides (PSPGs) for TKA. It was hypothesised that there would be no difference between post-op implant position and pre-op digital plan. Twenty-six patients were included in this non-inferiority trial. Software permitted matching of the pre-operative MRI scan (and therefore calculated prosthesis position) to a pre-operative CT scan and then to a post-operative full-leg CT scan to determine deviations from pre-op planning in all three anatomical planes. For the femoral component, mean absolute deviations from planning were 1.8° (SD 1.3), 2.5° (SD 1.6) and 1.6° (SD 1.4) in the frontal, sagittal and transverse planes, respectively. For the tibial component, mean absolute deviations from planning were 1.7° (SD 1.2), 1.7° (SD 1.5) and 3.2° (SD 3.6) in the frontal, sagittal and transverse planes, respectively. Absolute mean deviation from planned mechanical axis was 1.9°. The a priori specified null hypothesis for equivalence testing: the difference from planning is >3 or <-3 was rejected for all comparisons except for the tibial transverse plane. PSPG was able to adequately reproduce the pre-op plan in all planes, except for the tibial rotation in the transverse plane. Possible explanations for outliers are discussed and highlight the importance for adequate training surgeons before they start using PSPG in their day-by-day practise. Prospective cohort study, Level II.

  2. High tibial closing wedge osteotomy for medial compartment osteoarthrosis of knee

    PubMed Central

    Tuli, SM; Kapoor, Varun

    2008-01-01

    Background: Most patients of symptomatic osteoarthrosis of knee are associated with varus malalignment that is causative or contributory to painful arthrosis. It is rational to correct the malalignment to transfer the functional load to the unaffected or less affected compartment of the knee to relieve symptoms. We report the outcome of a simple technique of high tibial osteotomy in the medial compartment osteoarthrosis of the knee. Materials and Methods: Between 1996 and 2004 we performed closing wedge osteotomy in 78 knees in 65 patients. The patients selected for osteotomy were symptomatic essentially due to medial compartment osteoarthrosis associated with moderate genu varum. Of the 19 patients who had bilateral symptomatic disease 11 opted for high tibial osteotomy of their second knee 1-3 years after the first operation. Preoperative grading of osteoarthrosis and postoperative function was assessed using Japanese Orthopaedic Association (JOA) rating scale. Results: At a minimum follow-up of 2 years (range 2-9 years) 6-10° of valgus correction at the site of osteotomy was maintained, there was significant relief of pain while walking, negotiating stairs, squatting and sitting cross-legged. Walking distance in all patients improved by two to four times their preoperative distance of 200-400 m. No patient lost any preoperative knee function. The mean JOA scoring improved from preoperative 54 (40-65) to 77 (55-85) at final follow-up. Conclusion: Closing wedge high tibial osteotomy performed by our technique can be undertaken in any setup with moderate facilities. Operation related complications are minimal and avoidable. Kirschner wire fixation is least likely to interfere with replacement surgery if it becomes necessary. PMID:19823659

  3. Changing Sagittal-Plane Landing Styles to Modulate Impact and Tibiofemoral Force Magnitude and Directions Relative to the Tibia

    PubMed Central

    Shimokochi, Yohei; Ambegaonkar, Jatin P.; Meyer, Eric G.

    2016-01-01

    Context: Ground reaction force (GRF) and tibiofemoral force magnitudes and directions have been shown to affect anterior cruciate ligament loading during landing. However, the kinematic and kinetic factors modifying these 2 forces during landing are unknown. Objective: To clarify the intersegmental kinematic and kinetic links underlying the alteration of the GRF and tibiofemoral force vectors secondary to changes in the sagittal-plane body position during single-legged landing. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Twenty recreationally active participants (age = 23.4 ± 3.6 years, height = 171.0 ± 9.4 cm, mass = 73.3 ± 12.7 kg). Intervention(s): Participants performed single-legged landings using 3 landing styles: self-selected landing (SSL), body leaning forward and landing on the toes (LFL), and body upright with flat-footed landing (URL). Three-dimensional kinetics and kinematics were recorded. Main Outcome Measure(s): Sagittal-plane tibial inclination and knee-flexion angles, GRF magnitude and inclination angles relative to the tibia, and proximal tibial forces at peak tibial axial forces. Results: The URL resulted in less time to peak tibial axial forces, smaller knee-flexion angles, and greater magnitude and a more anteriorly inclined GRF vector relative to the tibia than did the SSL. These changes led to the greatest peak tibial axial and anterior shear forces in the URL among the 3 landing styles. Conversely, the LFL resulted in longer time to peak tibial axial forces, greater knee-flexion angles, and reduced magnitude and a more posteriorly inclined GRF vector relative to the tibia than the SSL. These changes in LFL resulted in the lowest peak tibial axial and largest posterior shear forces among the 3 landing styles. Conclusions: Sagittal-plane intersegmental kinematic and kinetic links strongly affected the magnitude and direction of GRF and tibiofemoral forces during the impact phase of single-legged landing

  4. Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures.

    PubMed

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2016-12-01

    To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images. Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

  5. Medial Tibial Stress Shielding: A Limitation of Cobalt Chromium Tibial Baseplates.

    PubMed

    Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Kim, Raymond H

    2017-02-01

    Stress shielding is a well-recognized complication associated with total knee arthroplasty. However, this phenomenon has not been thoroughly described. Specifically, no study to our knowledge has evaluated the radiographic impact of utilizing various tibial component compositions on tibial stress shielding. We retrospectively reviewed 3 cohorts of 50 patients that had a preoperative varus deformity and were implanted with a titanium, cobalt chromium (CoCr), or an all polyethylene tibial implant. A radiographic comparative analysis was performed to evaluate the amount of medial tibial bone loss in each cohort. In addition, a clinical outcomes analysis was performed on the 3 cohorts. The CoCr was noted to have a statistically significant increase in medial tibial bone loss compared with the other 2 cohorts. The all polyethylene cohort had a statistically significantly higher final Knee Society Score and was associated with the least amount of stress shielding. The CoCr tray is the most rigid of 3 implants that were compared in this study. Interestingly, this cohort had the highest amount of medial tibial bone loss. In addition, 1 patient in the CoCr cohort had medial soft tissue irritation which was attributed to a prominent medial tibial tray which required revision surgery to mitigate the symptoms. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Alignment in the transverse plane, but not sagittal or coronal plane, affects the risk of recurrent patella dislocation.

    PubMed

    Takagi, Shigeru; Sato, Takashi; Watanabe, Satoshi; Tanifuji, Osamu; Mochizuki, Tomoharu; Omori, Go; Endo, Naoto

    2017-11-17

    Abnormalities of lower extremity alignment (LEA) in recurrent patella dislocation (RPD) have been studied mostly by two-dimensional (2D) procedures leaving three-dimensional (3D) factors unknown. This study aimed to three-dimensionally examine risk factors for RPD in lower extremity alignment under the weight-bearing conditions. The alignment of 21 limbs in 15 RPD subjects was compared to the alignment of 24 limbs of 12 healthy young control subjects by an our previously reported 2D-3D image-matching technique. The sagittal, coronal, and transverse alignment in full extension as well as the torsional position of the femur (anteversion) and tibia (tibial torsion) under weight-bearing standing conditions were assessed by our previously reported 3D technique. The correlations between lower extremity alignment and RPD were assessed using multiple logistic regression analysis. The difference of lower extremity alignment in RPD between under the weight-bearing conditions and under the non-weight-bearing conditions was assessed. In the sagittal and coronal planes, there was no relationship (statistically or by clinically important difference) between lower extremity alignment angle and RPD. However, in the transverse plane, increased external tibial rotation [odds ratio (OR) 1.819; 95% confidence interval (CI) 1.282-2.581], increased femoral anteversion (OR 1.183; 95% CI 1.029-1.360), and increased external tibial torsion (OR 0.880; 95% CI 0.782-0.991) were all correlated with RPD. The tibia was more rotated relative to femur at the knee joint in the RPD group under the weight-bearing conditions compared to under the non-weight-bearing conditions (p < 0.05). This study showed that during weight-bearing, alignment parameters in the transverse plane related to the risk of RPD, while in the sagittal and coronal plane alignment parameters did not correlate with RPD. The clinical importance of this study is that the 3D measurements more directly, precisely, and sensitively

  7. Comparison of intraoperative anthropometric measurements of the proximal tibia and tibial component in total knee arthroplasty.

    PubMed

    Miyatake, Naohisa; Sugita, Takehiko; Aizawa, Toshimi; Sasaki, Akira; Maeda, Ikuo; Kamimura, Masayuki; Fujisawa, Hirokazu; Takahashi, Atsushi

    2016-09-01

    Precise matching of the tibial component and resected bony surfaces and proper rotational implanting of the tibial component are crucial for successful total knee arthroplasty. We aimed to analyze the exact anthropometric proximal tibial data of Japanese patients undergoing total knee arthroplasty and correlate the measurements with the dimensions of current total knee arthroplasty systems. A total of 703 knees in 566 Japanese patients who underwent total knee arthroplasty for osteoarthritis were included. The bone resection in the proximal tibia was performed perpendicular to the tibial axis in the frontal plane. Measurements of the proximal tibia were intraoperatively obtained after proximal tibial preparation. There were significant positive correlations between the lateral anteroposterior and medial anteroposterior and mediolateral dimensions. A progressive decrease in the mediolateral/lateral anteroposterior ratio with an increasing lateral anteroposterior dimension or the mediolateral/anteroposterior ratio with an increasing anteroposterior dimension was observed. The lateral anteroposterior dimension was smaller than the medial anteroposterior dimension by a mean of 4.8 ± 2.0 mm. The proximal tibia exhibited asymmetry between the lateral and medial plateaus. A comparison of the morphological data and dimensions of the implants, one of which was a symmetric tibial component (NexGen) and the others were asymmetric (Genesis II and Persona), indicated that an asymmetric tibial component could be beneficial to maximize tibial plateau coverage. This study provided important reference data for designing a proper tibial component for Japanese people. The proximal tibial cut surface was asymmetric. There was wide dispersion in the lateral anteroposterior, medial anteroposterior, and mediolateral dimensions depending on the patient. Our data showed that the tibial components of the Genesis II and Persona rather than that of the NexGen may be preferable for

  8. Proximal Tibial Bone Graft

    MedlinePlus

    ... All Site Content AOFAS / FootCareMD / Treatments Proximal Tibial Bone Graft Page Content What is a bone graft? Bone grafts may be needed for various ... the proximal tibia. What is a proximal tibial bone graft? Proximal tibial bone graft (PTBG) is a ...

  9. High altitude hypoxia as a factor that promotes tibial growth plate development in broiler chickens

    PubMed Central

    Huang, Shucheng; Zhang, Lihong; Rehman, Mujeeb Ur; Iqbal, Muhammad Kashif; Lan, Yanfang; Mehmood, Khalid; Zhang, Hui; Qiu, Gang; Nabi, Fazul; Yao, Wangyuan; Wang, Meng; Li, Jiakui

    2017-01-01

    Tibial dyschondroplasia (TD) is one of the most common problems in the poultry industry and leads to lameness by affecting the proximal growth plate of the tibia. However, due to the unique environmental and geographical conditions of Tibet, no case of TD has been reported in Tibetan chickens (TBCs). The present study was designed to investigate the effect of high altitude hypoxia on blood parameters and tibial growth plate development in chickens using the complete blood count, morphology, and histological examination. The results of this study showed an undesirable impact on the overall performance, body weight, and mortality of Arbor Acres chickens (AACs) exposed to a high altitude hypoxic environment. However, AACs raised under hypoxic conditions showed an elevated number of red blood cells (RBCs) and an increase in hemoglobin and hematocrit values on day 14 compared to the hypobaric normoxia group. Notably, the morphology and histology analyses showed that the size of tibial growth plates in AACs was enlarged and that the blood vessel density was also higher after exposure to the hypoxic environment for 14 days, while no such change was observed in TBCs. Altogether, our results revealed that the hypoxic environment has a potentially new role in increasing the blood vessel density of proximal tibial growth plates to strengthen and enhance the size of the growth plates, which may provide new insights for the therapeutic manipulation of hypoxia in poultry TD. PMID:28282429

  10. Lower extremity energy absorption and biomechanics during landing, part I: sagittal-plane energy absorption analyses.

    PubMed

    Norcross, Marc F; Lewek, Michael D; Padua, Darin A; Shultz, Sandra J; Weinhold, Paul S; Blackburn, J Troy

    2013-01-01

    Eccentric muscle actions of the lower extremity absorb kinetic energy during landing. Greater total sagittal-plane energy absorption (EA) during the initial impact phase (INI) of landing has been associated with landing biomechanics considered high risk for anterior cruciate ligament (ACL) injury. We do not know whether groups with different INI EA magnitudes exhibit meaningful differences in ACL-related landing biomechanics and whether INI EA might be useful to identify ACL injury-risk potential. To compare biomechanical factors associated with noncontact ACL injury among sagittal-plane INI EA groups and to determine whether an association exists between sex and sagittal-plane INI EA group assignment to evaluate the face validity of using sagittal-plane INI EA to identify ACL injury risk. Descriptive laboratory study. Research laboratory. A total of 82 (41 men, 41 women; age = 21.0 ± 2.4 years, height = 1.74 ± 0.10 m, mass = 70.3 ± 16.1 kg) healthy, physically active individuals volunteered. We assessed landing biomechanics using an electromagnetic motion-capture system and force plate during a double-legged jump-landing task. Total INI EA was used to group participants into high, moderate, and low tertiles. Sagittal- and frontal-plane knee kinematics; peak vertical and posterior ground reaction forces (GRFs); anterior tibial shear force; and internal hip extension, knee extension, and knee varus moments were identified and compared across groups using 1-way analyses of variance. We used a χ (2) analysis to compare male and female representation in the high and low groups. The high group exhibited greater knee-extension moment and posterior GRFs than both the moderate (P < .05) and low (P < .05) groups and greater anterior tibial shear force than the low group (P < .05). No other group differences were noted. Women were not represented more than men in the high group (χ(2) = 1.20, P = .27). Greater sagittal-plane INI EA likely indicates greater ACL loading

  11. Does Tibial Slope Affect Perception of Coronal Alignment on a Standing Anteroposterior Radiograph?

    PubMed

    Schwartz, Adam J; Ravi, Bheeshma; Kransdorf, Mark J; Clarke, Henry D

    2017-07-01

    A standing anteroposterior (AP) radiograph is commonly used to evaluate coronal alignment following total knee arthroplasty (TKA). The impact of coronal alignment on TKA outcomes is controversial, perhaps due to variability in imaging and/or measurement technique. We sought to quantify the effect of image rotation and tibial slope on coronal alignment. Using a standard extramedullary tibial alignment guide, 3 cadaver legs were cut to accept a tibial tray at 0°, 3°, and 7° of slope. A computed tomography scan of the entire tibia was obtained for each specimen to confirm neutral coronal alignment. Images were then obtained at progressive 10° intervals of internal and external rotation up to 40° maximum in each direction. Images were then randomized and 5 blinded TKA surgeons were asked to determine coronal alignment. Continuous data values were transformed to categorical data (neutral [0], valgus [L], and varus [R]). Each 10° interval of external rotation of a 7° sloped tibial cut (or relative internal rotation of a tibial component viewed in the AP plane) resulted in perception of an additional 0.75° of varus. The slope of the proximal tibia bone cut should be taken into account when measuring coronal alignment on a standing AP radiograph. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Changes in patellofemoral alignment do not cause clinical impact after open-wedge high tibial osteotomy.

    PubMed

    Lee, Yong Seuk; Lee, Sang Bok; Oh, Won Seok; Kwon, Yong Eok; Lee, Beom Koo

    2016-01-01

    The objectives of this study were (1) to evaluate the clinical and radiologic outcomes of open-wedge high tibial osteotomy focusing on patellofemoral alignment and (2) to search for correlation between variables and patellofemoral malalignment. A total of 46 knees (46 patients) from 32 females and 14 males who underwent open-wedge high tibial osteotomy were included in this retrospective case series. Outcomes were evaluated using clinical scales and radiologic parameters at the last follow-up. Pre-operative and final follow-up values were compared for the outcome analysis. For the focused analysis of the patellofemoral joint, correlation analyses between patellofemoral variables and pre- and post-operative weight-bearing line (WBL), clinical score, posterior slope, Blackburn Peel ratio, lateral patellar tilt, lateral patellar shift, and congruence angle were performed. The minimum follow-up period was 2 years and median follow-up period was 44 months (range 24-88 months). The percentage of weight-bearing line was shifted from 17.2 ± 11.1 to 56.7 ± 12.7%, and it was statistically significant (p < 0.01). Regarding the clinical results, statistical significance was observed using all scores (p < 0.01). In the radiologic evaluation, patellar descent was observed with statistical significance (p < 0.01). Last follow-up lateral patellar tilt was decreased with statistical significance (p < 0.01). In correlation analysis between variables of patellofemoral malalignment, the pre-operative weight-bearing line showed an association with the change in lateral patellar tilt and lateral patellar shift (correlation coefficient: 0.3). After open-wedge high tibial osteotomy, clinical results showed improvement, compared to pre-operative values. The patellar tilt and lateral patellar shift were not changed; however, descent of the patella was observed. Therefore, mild patellofemoral problems should not be a contraindication of the open-wedge high tibial osteotomy. Case series

  13. A Biomechanical Study of Posteromedial Tibial Plateau Fracture Stability: Do They All Require Fixation?

    PubMed

    Cuéllar, Vanessa G; Martinez, Danny; Immerman, Igor; Oh, Cheongeun; Walker, Peter S; Egol, Kenneth A

    2015-07-01

    Although the posteromedial fragment in tibial plateau fractures is often considered unstable, biomechanical evidence supporting this view is lacking. We aimed to evaluate the stability of the fragment in a cadaver model. Our hypothesis was that under the expected small axial force during rehabilitation and the combined effects of this force with shear force, internal rotation torque, and varus moment, the most common posteromedial tibial fragment morphology could maintain stability in early flexion. Axial compression force alone or combined with posterior shear, internal rotation torque, or varus moment was applied to the femurs of 5 fresh cadaveric knees. A Tekscan pressure mapping system was used to measure pressure and contact area between the femoral condyles, meniscus, and tibial plateau. A Microscribe 3D digitizer was used to define the 3-dimensional positions of the femur and tibia. A 10-mm and then a 20-mm osteotomy was created with a saw at an angle of 30 degrees in the axial plane with respect to the tangent of the posterior tibial plateau and 75 degrees in the sagittal plane, representing a typical posteromedial fracture fragment. At each flexion angle (15, 30, 60, 90, and 120 degrees) and loading condition (axial compression only, compression with shear force, torque, and varus moment), distal displacement of the medial femoral condyle and the tibial fracture fragments was determined. For the 10-mm fragment, medial femoral condyle displacement was little affected up to approximately 30-degree flexion, after which it increased. For the 20-mm fragment, there was progressive medial femoral condyle displacement with increasing flexion from baseline. However, for the 10- and 20-mm fragments themselves, displacements were noted at every flexion angle, starting at 1.7 mm inferior displacement with 15 degrees of flexion and internal rotation torque and up to 10.2 mm displacement with 90 degrees of flexion and varus bending moment. In this cadaveric model of a

  14. Theoretical discrepancy between cage size and efficient tibial tuberosity advancement in dogs treated for cranial cruciate ligament rupture.

    PubMed

    Etchepareborde, S; Mills, J; Busoni, V; Brunel, L; Balligand, M

    2011-01-01

    To calculate the difference between the desired tibial tuberosity advancement (TTA) along the tibial plateau axis and the advancement truly achieved in that direction when cage size has been determined using the method of Montavon and colleagues. To measure the effect of this difference on the final patellar tendon-tibial plateau angle (PTA) in relation to the ideal 90°. Trigonometry was used to calculate the theoretical actual advancement of the tibial tuberosity in a direction parallel to the tibial plateau that would be achieved by the placement of a cage at the level of the tibial tuberosity in the osteotomy plane of the tibial crest. The same principle was used to calculate the size of the cage that would have been required to achieve the desired advancement. The effect of the difference between the desired advancement and the actual advancement achieved on the final PTA was calculated. For a given desired advancement, the greater the tibial plateau angle (TPA), the greater the difference between the desired advancement and the actual advancement achieved. The maximum discrepancy calculated was 5.8 mm for a 12 mm advancement in a case of extreme TPA (59°). When the TPA was less than 31°, the PTA was in the range of 90° to 95°. A discrepancy does exist between the desired tibial tuberosity advancement and the actual advancement in a direction parallel to the TPA, when the tibial tuberosity is not translated proximally. Although this has an influence on the final PTA, further studies are warranted to evaluate whether this is clinically significant.

  15. Tibial tunnel aperture location during single-bundle posterior cruciate ligament reconstruction: comparison of tibial guide positions.

    PubMed

    Shin, Young-Soo; Han, Seung-Beom; Hwang, Yeok-Ku; Suh, Dong-Won; Lee, Dae-Hee

    2015-05-01

    We aimed to compare posterior cruciate ligament (PCL) tibial tunnel location after tibial guide insertion medial (between the PCL remnant and the medial femoral condyle) and lateral (between the PCL remnant and the anterior cruciate ligament) to the PCL stump as determined by in vivo 3-dimensional computed tomography (3D-CT). Tibial tunnel aperture location was analyzed by immediate postoperative in vivo CT in 66 patients who underwent single-bundle PCL reconstruction, 31 by over-the-PCL and 35 by under-the-PCL tibial guide insertion techniques. Tibial tunnel positions were measured in the medial to lateral and proximal to distal directions of the posterior proximal tibia. The center of the tibial tunnel aperture was located more laterally (by 2.7 mm) in the over-the-PCL group than in the under-the-PCL group (P = .040) and by a relative percentage (absolute value/tibial width) of 3.2% (P = .031). Tibial tunnel positions in the proximal to distal direction, determined by absolute value and relative percentage, were similar in the 2 groups. Tibial tunnel apertures were located more laterally after lateral-to-the-PCL tibial guide insertion than after medial-to-the-PCL tibial guide insertion. There was, however, no significant difference between these techniques in distance from the joint line to the tibial tunnel aperture. Insertion lateral to the PCL stump may result in better placement of the PCL in its anatomic footprint. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Effects of tibial slope changes in the stability of fixed bearing medial unicompartmental arthroplasty in anterior cruciate ligament deficient knees.

    PubMed

    Suero, Eduardo M; Citak, Musa; Cross, Michael B; Bosscher, Marianne R F; Ranawat, Anil S; Pearle, Andrew D

    2012-08-01

    Patients with anterior cruciate ligament (ACL) deficiency may have increased failure rates with UKA as a result of abnormal contact stresses and altered knee kinematics. Variations in the slope of the tibial component in UKA may alter tibiofemoral translation, and affect outcomes. This cadaveric study evaluated tibiofemoral translation during the Lachman and pivot shift tests after changing the slope of a fixed bearing unicondylar tibial component. Sectioning the ACL increased tibiofemoral translation in both the Lachman and pivot shift tests (P<0.05). Tibial slope leveling (decreasing the posterior slope) of the polyethylene insert in a UKA decreases anteroposterior tibiofemoral translation in the sagittal plane to a magnitude similar to that of the intact knee. With 8° of tibial slope leveling, anterior tibial translation during the Lachman test decreased by approximately 5mm. However, no variation in slope altered the pivot shift kinematics in the ACL deficient knees. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Increased revision rate with posterior tibial tunnel placement after using the 70-degree tibial guide in ACL reconstruction.

    PubMed

    Inderhaug, Eivind; Raknes, Sveinung; Østvold, Thomas; Solheim, Eirik; Strand, Torbjørn

    2017-01-01

    To map knee morphology radiographically in a population with a torn ACL and to investigate whether anatomic factors could be related to outcomes after ACL reconstruction at mid- to long-term follow-up. Further, we wanted to assess tibial tunnel placement after using the 70-degree "anti-impingement" tibial tunnel guide and investigate any relation between tunnel placement and revision surgery. Patients undergoing ACL reconstruction involving the 70-degree tibial guide from 2003 to 2008 were included. Two independent investigators analysed pre- and post-operative radiographs. Demographic data and information on revision surgery were collected from an internal database. Anatomic factors and post-operative tibial tunnel placements were investigated as predictors of revision. Three-hundred and seventy-seven patients were included in the study. A large anatomic variation with significant differences between men and women was seen. None of the anatomic factors could be related to a significant increase in revision rate. Patients with a posterior tibial tunnel placement, defined as 50 % or more posterior on the Amis and Jakob line, did, however, have a higher risk of revision surgery compared to patients with an anterior tunnel placement (P = 0.03). Use of the 70-degree tibial guide did result in a high incidence (47 %) of posterior tibial tunnel placements associated with an increased rate of revision surgery. The current study was, however, not able to identify any anatomic variation that could be related to a higher risk of revision surgery. Avoiding graft impingement from the femoral roof in anterior tibial tunnel placements is important, but the insight that overly posterior tunnel placement can lead to inferior outcome should also be kept in mind when performing ACL surgery. IV.

  18. Tibial bone fractures occurring after medioproximal tibial bone grafts for oral and maxillofacial reconstruction.

    PubMed

    Kim, Il-Kyu; Cho, Hyun-Young; Pae, Sang-Pill; Jung, Bum-Sang; Cho, Hyun-Woo; Seo, Ji-Hoon

    2013-12-01

    Oral and maxillofacial defects often require bone grafts to restore missing tissues. Well-recognized donor sites include the anterior and posterior iliac crest, rib, and intercalvarial diploic bone. The proximal tibia has also been explored as an alternative donor site. The use of the tibia for bone graft has many benefits, such as procedural ease, adequate volume of cancellous and cortical bone, and minimal complications. Although patients rarely complain of pain, swelling, discomfort, or dysfunction, such as gait disturbance, both patients and surgeons should pay close attention to such after effects due to the possibility of tibial fracture. The purpose of this study is to analyze tibial fractures that occurring after osteotomy for a medioproximal tibial graft. An analysis was intended for patients who underwent medioproximal tibial graft between March 2004 and December 2011 in Inha University Hospital. A total of 105 subjects, 30 females and 75 males, ranged in age from 17 to 78 years. We investigated the age, weight, circumstance, and graft timing in relation to tibial fracture. Tibial fractures occurred in four of 105 patients. There were no significant differences in graft region, shape, or scale between the fractured and non-fractured patients. Patients who undergo tibial grafts must be careful of excessive external force after the operation.

  19. High-energy fractures of the tibial plateau. Knee function after longer follow-up.

    PubMed

    Weigel, Dennis P; Marsh, J Lawrence

    2002-09-01

    Studies of the long-term outcomes of treatment of fractures of the tibial plateau have included wide mixtures of fracture types and mostly low-energy split and split-depression fractures. The long-term results of treatment of high-energy intra-articular proximal tibial fractures are unknown. The purpose of this study was to assess the function of the knee and the development of arthrosis at a minimum of five years after injury in a consecutive series of patients in whom a high-energy fracture of the tibial plateau had been treated with a uniform technique of external fixation. Between July 1988 and December 1994, thirty patients with a total of thirty-one fractures of the tibial plateau were treated with a monolateral external fixator and limited internal fixation of the articular surface. Follow-up data on twenty-four knees in twenty-three patients were obtained at a mean of ninety-eight months. Twenty patients (twenty knees) returned specifically for the study, at which time they completed an Iowa Knee Score questionnaire and a Short Form-36 (SF-36) general health survey, a physical examination was performed, and weight-bearing radiographs were made. The results of the SF-36 evaluations for fourteen patients and the Knee Scores for twelve were compared with those obtained five years previously, at two to four years after the injury. After healing, no patient required a secondary reconstructive procedure. The range of motion of the knee averaged 3 degrees of extension to 120 degrees flexion, which was an average of 87% of the total arc of the contralateral knee. The average Iowa Knee Score was 90 points (range, 72 to 100 points). For twelve patients, the Iowa Knee Score previously recorded at two to four years averaged 92 points, as did the score at the time of the latest follow-up. Thirteen patients rated their outcome as excellent; six, as good; and three, as fair. Fifteen patients were working, and ten of them were performing strenuous labor. Radiographs showed

  20. Ankle joint pressure changes in high tibial and distal femoral osteotomies: a cadaver study.

    PubMed

    Krause, F; Barandun, A; Klammer, G; Zderic, I; Gueorguiev, B; Schmid, T

    2017-01-01

    To assess the effect of high tibial and distal femoral osteotomies (HTO and DFO) on the pressure characteristics of the ankle joint. Varus and valgus malalignment of the knee was simulated in human cadaver full-length legs. Testing included four measurements: baseline malalignment, 5° and 10° re-aligning osteotomy, and control baseline malalignment. For HTO, testing was rerun with the subtalar joint fixed. In order to represent half body weight, a 300 N force was applied onto the femoral head. Intra-articular sensors captured ankle pressure. In the absence of restriction of subtalar movement, insignificant migration of the centre of force and changes of maximal pressure were seen at the ankle joint. With restricted subtalar motion, more significant lateralisation of the centre of force were seen with the subtalar joint in varus than in valgus position. Changes in maximum pressure were again not significant. The re-alignment of coronal plane knee deformities by HTO and DFO altered ankle pressure characteristics. When the subtalar joint was fixed in the varus position, migration of centre of force after HTO was more significant than when the subtalar joint was fixed in valgus. Cite this article: Bone Joint J 2017;99-B:59-65. ©2017 The British Editorial Society of Bone & Joint Surgery.

  1. Lower Extremity Energy Absorption and Biomechanics During Landing, Part I: Sagittal-Plane Energy Absorption Analyses

    PubMed Central

    Norcross, Marc F.; Lewek, Michael D.; Padua, Darin A.; Shultz, Sandra J.; Weinhold, Paul S.; Blackburn, J. Troy

    2013-01-01

    Context: Eccentric muscle actions of the lower extremity absorb kinetic energy during landing. Greater total sagittal-plane energy absorption (EA) during the initial impact phase (INI) of landing has been associated with landing biomechanics considered high risk for anterior cruciate ligament (ACL) injury. We do not know whether groups with different INI EA magnitudes exhibit meaningful differences in ACL-related landing biomechanics and whether INI EA might be useful to identify ACL injury-risk potential. Objective: To compare biomechanical factors associated with noncontact ACL injury among sagittal-plane INI EA groups and to determine whether an association exists between sex and sagittal-plane INI EA group assignment to evaluate the face validity of using sagittal-plane INI EA to identify ACL injury risk. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: A total of 82 (41 men, 41 women; age = 21.0 ± 2.4 years, height = 1.74 ± 0.10 m, mass = 70.3 ± 16.1 kg) healthy, physically active individuals volunteered. Intervention(s): We assessed landing biomechanics using an electromagnetic motion-capture system and force plate during a double-legged jump-landing task. Main Outcome Measure(s): Total INI EA was used to group participants into high, moderate, and low tertiles. Sagittal- and frontal-plane knee kinematics; peak vertical and posterior ground reaction forces (GRFs); anterior tibial shear force; and internal hip extension, knee extension, and knee varus moments were identified and compared across groups using 1-way analyses of variance. We used a χ2 analysis to compare male and female representation in the high and low groups. Results: The high group exhibited greater knee-extension moment and posterior GRFs than both the moderate (P < .05) and low (P < .05) groups and greater anterior tibial shear force than the low group (P < .05). No other group differences were noted. Women were not represented more than

  2. Tibial plateau fracture following gracilis-semitendinosus anterior cruciate ligament reconstruction: The tibial tunnel stress-riser.

    PubMed

    Sundaram, R O; Cohen, D; Barton-Hanson, N

    2006-06-01

    Tibial plateau fractures following anterior cruciate ligament (ACL) reconstruction are extremely rare. This is the first reported case of a tibial plateau fracture following four-strand gracilis-semitendinosus autograft ACL reconstruction. The tibial tunnel alone may behave as a stress riser which can significantly reduce bone strength.

  3. Tibial Tray Thickness Significantly Increases Medial Tibial Bone Resorption in Cobalt-Chromium Total Knee Arthroplasty Implants.

    PubMed

    Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Miner, Todd M; Springer, Bryan D; Kim, Raymond H

    2017-01-01

    Stress shielding is an uncommon complication associated with primary total knee arthroplasty. Patients are frequently identified radiographically with minimal clinical symptoms. Very few studies have evaluated risk factors for postoperative medial tibial bone loss. We hypothesized that thicker cobalt-chromium tibial trays are associated with increased bone loss. We performed a retrospective review of 100 posterior stabilized, fixed-bearing total knee arthroplasty where 50 patients had a 4-mm-thick tibial tray (thick tray cohort) and 50 patients had a 2.7-mm-thick tibial tray (thin tray cohort). A clinical evaluation and a radiographic assessment of medial tibial bone loss were performed on both cohorts at a minimum of 2 years postoperatively. Mean medial tibial bone loss was significantly higher in the thick tray cohort (1.07 vs 0.16 mm; P = .0001). In addition, there were significantly more patients with medial tibial bone loss in the thick tray group compared with the thin tray group (44% vs 10%, P = .0002). Despite these differences, there were no statistically significant differences in range of motion, knee society score, complications, or revision surgeries performed. A thicker cobalt-chromium tray was associated with significantly more medial tibial bone loss. Despite these radiographic findings, we found no discernable differences in clinical outcomes in our patient cohort. Further study and longer follow-up are needed to understand the effects and clinical significance of medial tibial bone loss. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. The effect of platelet-rich plasma on osseous healing in dogs undergoing high tibial osteotomy.

    PubMed

    Franklin, Samuel P; Burke, Emily E; Holmes, Shannon P

    2017-01-01

    The purpose of this study was to investigate whether platelet-rich plasma (PRP) enhances osseous healing in conjunction with a high tibial osteotomy in dogs. Randomized controlled trial. Sixty-four client-owned pet dogs with naturally occurring rupture of the anterior cruciate ligament and that were to be treated with a high tibial osteotomy (tibial plateau leveling osteotomy) were randomized into the treatment or control group. Dogs in the treatment group received autologous platelet-rich plasma activated with calcium chloride and bovine thrombin to produce a well-formed PRP gel that was placed into the osteotomy at the time of surgery. Dogs in the control group received saline lavage of the osteotomy. All dogs had the osteotomy stabilized with identical titanium alloy implants and all aspects of the surgical procedure and post-operative care were identical among dogs of the two groups. Bone healing was assessed at exactly 28, 49, and 70 days after surgery with radiography and ultrasonography and with MRI at day 28. The effect of PRP on bone healing was assessed using a repeated measures analysis of covariance with radiographic and ultrasonographic data and using a t-test with the MRI data. Sixty dogs completed the study. There were no significant differences in age, weight, or gender distribution between the treatment and control groups. Twenty-seven dogs were treated with PRP and 33 were in the control group. The average platelet concentration of the PRP was 1.37x106 platelets/μL (±489x103) with a leukocyte concentration of 5.45x103/μL (±3.5x103). All dogs demonstrated progressive healing over time and achieved clinically successful outcomes. Time since surgery and patient age were significant predictors of radiographic healing and time since surgery was a significant predictor of ultrasonographic assessment of healing. There was no significant effect of PRP treatment as assessed radiographically, ultrasonographically, or with MRI. The PRP used in this study

  5. ACL double-bundle reconstruction with one tibial tunnel provides equal stability compared to two tibial tunnels.

    PubMed

    Drews, Björn Holger; Seitz, Andreas Martin; Huth, Jochen; Bauer, Gerhard; Ignatius, Anita; Dürselen, Lutz

    2017-05-01

    The purpose of this study was to investigate whether an anterior cruciate ligament (ACL) double-bundle reconstruction with one tibial tunnel displays the same in vitro stability as a conventional double-bundle reconstruction with two tibial tunnels when using the same tensioning protocol. In 11 fresh-frozen cadaveric knees, ACL double-bundle reconstruction with one and two tibial tunnels was performed. The two grafts were tightened using 80 N in different flexion angles (anteromedial-bundle at 60° and posterolateral-bundle at 15°). Anterior tibial translation (134 N) and translation with combined rotatory and valgus loads (10 Nm valgus stress and 4 Nm internal tibial torque) were determined at 0°, 30°, 60° and 90° flexion. Measurements were taken in intact ACL, resected ACL, three-tunnel reconstruction and four-tunnel reconstruction. Additionally, the tension on the grafts was determined. Student's t test was performed for statistical analysis of the related samples. Significance was set at p < 0.017 according to Bonferroni correction. The two reconstructive techniques displayed no significant differences in comparison with the intact ACL in anterior tibial translation at 0°, 60° and 90° of flexion. The same results were obtained for the anterior tibial translation with a combined rotatory load at 60° and 90°. When directly comparing both reconstructive techniques, there were no significant differences for the anterior tibial translation and combined rotatory load at all flexion angles. The measured tension on grafts displayed similar load sharing between both bundles. Except at full extension, both grafts displayed a significantly different tension increase under anterior tibial translation for both techniques (p = 0.0086). Tightening both bundles in ACL double-bundle reconstruction with one or two tibial tunnels in different flexion angles achieved comparable restoration of stability, although there was different load sharing on the bundles

  6. Tibial lengthening over humeral and tibial intramedullary nails in patients with sequelae of poliomyelitis: a comparative study.

    PubMed

    Chen, Daoyun; Chen, Jianmin; Jiang, Yao; Liu, Fanggang

    2011-06-01

    Leg discrepancy is common after poliomyelitis. Tibial lengthening is an effective way to solve this problem. It is believed lengthening over a tibial intramedullary nail can provide a more comfortable lengthening process than by the conventional technique. However, patients with sequelae of poliomyelitis typically have narrow intramedullary canals allowing limited space for inserting a tibial intramedullary nail and Kirschner wires. To overcome this problem, we tried using humeral nails instead of tibial nails in the lengthening procedure. In this study, we used humeral nails in 20 tibial lengthening procedures and compared the results with another group of patients who were treated with tibial lengthening over tibial intramedullary nails. The mean consolidation index, percentage of increase and external fixation index did not show significant differences between the two groups. However, less blood loss and shorter operating time were noted in the humeral nail group. More patients encountered difficulty with the inserted intramedullary nail in the tibial nail group procedure. The complications did not show a statistically significant difference between the two techniques on follow-up. In conclusion, we found the humeral nail lengthening technique was more suitable in leg discrepancy patients with sequelae of poliomyelitis.

  7. Primary Ankle Arthrodesis for Severely Comminuted Tibial Pilon Fractures.

    PubMed

    Al-Ashhab, Mohamed E

    2017-03-01

    Management of severely comminuted, complete articular tibial pilon fractures (Rüedi and Allgöwer type III) remains a challenge, with few treatment options providing good clinical outcomes. Twenty patients with severely comminuted tibial pilon fractures underwent primary ankle arthrodesis with a retrograde calcaneal nail and autogenous fibular bone graft. The fusion rate was 100% and the varus malunion rate was 10%. Fracture union occurred at a mean of 16 weeks (range, 13-18 weeks) postoperatively. Primary ankle arthrodesis is a successful method for treating highly comminuted tibial pilon fractures, having a low complication rate and a high satisfaction score. [Orthopedics. 2017; 40(2):e378-e381.]. Copyright 2016, SLACK Incorporated.

  8. Cranial tibial wedge osteotomy: a technique for eliminating cranial tibial thrust in cranial cruciate ligament repair.

    PubMed

    Slocum, B; Devine, T

    1984-03-01

    Cranial tibial wedge osteotomy, surgical technique for cranial cruciate ligament rupture, was performed on 19 stifles in dogs. This procedure leveled the tibial plateau, thus causing weight-bearing forces to be compressive and eliminating cranial tibial thrust. Without cranial tibial thrust, which was antagonistic to the cranial cruciate ligament and its surgical reconstruction, cruciate ligament repairs were allowed to heal without constant loads. This technique was meant to be used as an adjunct to other cranial cruciate ligament repair techniques.

  9. Effect of Tibial Plateau Levelling Osteotomy on Cranial Tibial Subluxation in the Feline Cranial Cruciate Deficient Stifle Joint: An Ex Vivo Experimental Study.

    PubMed

    Bilmont, A; Retournard, M; Asimus, E; Palierne, S; Autefage, A

    2018-06-11

     This study evaluated the effects of tibial plateau levelling osteotomy on cranial tibial subluxation and tibial rotation angle in a model of feline cranial cruciate ligament deficient stifle joint.  Quadriceps and gastrocnemius muscles were simulated with cables, turnbuckles and a spring in an ex vivo limb model. Cranial tibial subluxation and tibial rotation angle were measured radiographically before and after cranial cruciate ligament section, and after tibial plateau levelling osteotomy, at postoperative tibial plateau angles of +5°, 0° and -5°.  Cranial tibial subluxation and tibial rotation angle were not significantly altered after tibial plateau levelling osteotomy with a tibial plateau angle of +5°. Additional rotation of the tibial plateau to a tibial plateau angle of 0° and -5° had no significant effect on cranial tibial subluxation and tibial rotation angle, although 2 out of 10 specimens were stabilized by a postoperative tibial plateau angle of -5°. No stabilization of the cranial cruciate ligament deficient stifle was observed in this model of the feline stifle, after tibial plateau levelling osteotomy.  Given that stabilization of the cranial cruciate ligament deficient stifle was not obtained in this model, simple transposition of the tibial plateau levelling osteotomy technique from the dog to the cat may not be appropriate. Schattauer GmbH Stuttgart.

  10. Tension Band Plating for Chronic Anterior Tibial Stress Fractures in High-Performance Athletes.

    PubMed

    Zbeda, Robert M; Sculco, Peter K; Urch, Ekaterina Y; Lazaro, Lionel E; Borens, Olivier; Williams, Riley J; Lorich, Dean G; Wellman, David S; Helfet, David L

    2015-07-01

    Anterior tibial stress fractures are associated with high rates of delayed union and nonunion, which can be particularly devastating to a professional athlete who requires rapid return to competition. Current surgical treatment strategies include intramedullary nailing, which has satisfactory rates of fracture union but an associated risk of anterior knee pain. Anterior tension band plating is a biomechanically sound alternative treatment for these fractures. Tension band plating of chronic anterior tibial stress fractures leads to rapid healing and return to physical activity and avoids the anterior knee pain associated with intramedullary nailing. Case series; Level of evidence, 4. Between 2001 and 2013, there were 13 chronic anterior tibial stress fractures in 12 professional or collegiate athletes who underwent tension band plating after failing nonoperative management. Patient charts were retrospectively reviewed for demographics, injury history, and surgical details. Radiographs were used to assess time to osseous union. Follow-up notes and phone interviews were used to determine follow-up time, return to training time, and whether the patient was able to return to competition. Cases included 13 stress fractures in 12 patients (9 females, 3 males). Five patients were track-and-field athletes, 4 patients played basketball, 2 patients played volleyball, and 1 was a ballet dancer. Five patients were Division I collegiate athletes and 7 were professional or Olympic athletes. Average age at time of surgery was 23.6 years (range, 20-32 years). Osseous union occurred on average at 9.6 weeks (range, 5.3-16.9 weeks) after surgery. Patients returned to training on average at 11.1 weeks (range, 5.7-20 weeks). Ninety-two percent (12/13) eventually returned to preinjury competition levels. Thirty-eight percent (5/13) underwent removal of hardware for plate prominence. There was no incidence of infection or nonunion. Anterior tension band plating for chronic tibial stress

  11. Multiobjective optimization of cartilage stress for non-invasive, patient-specific recommendations of high tibial osteotomy correction angle - a novel method to investigate alignment correction.

    PubMed

    Zheng, Keke; Scholes, Corey J; Chen, Junning; Parker, David; Li, Qing

    2017-04-01

    Medial opening wedge high tibial osteotomy (MOWHTO) is a surgical procedure to treat knee osteoarthritis associated with varus deformity. However, the ideal final alignment of the Hip-Knee-Ankle (HKA) angle in the frontal plane, that maximizes procedural success and post-operative knee function, remains controversial. Therefore, the purpose of this study was to introduce a subject-specific modeling procedure in determining the biomechanical effects of MOWHTO alignment on tibiofemoral cartilage stress distribution. A 3D finite element knee model derived from magnetic resonance imaging of a healthy participant was manipulated in-silico to simulate a range of final HKA angles (i.e. 0.2°, 2.7°, 3.9° and 6.6° valgus). Loading and boundary conditions were assigned based on subject-specific kinematic and kinetic data from gait analysis. Multiobjective optimization was used to identify the final alignment that balanced compressive and shear forces between medial and lateral knee compartments. Peak stresses decreased in the medial and increased in the lateral compartment as the HKA was shifted into valgus, with balanced loading occurring at angles of 4.3° and 2.9° valgus for the femoral and tibial cartilage respectively. The concept introduced here provides a platform for non-invasive, patient-specific preoperative planning of the osteotomy for medial compartment knee osteoarthritis. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Understanding the etiology of the posteromedial tibial stress fracture.

    PubMed

    Milgrom, Charles; Burr, David B; Finestone, Aharon S; Voloshin, Arkady

    2015-09-01

    Previous human in vivo tibial strain measurements from surface strain gauges during vigorous activities were found to be below the threshold value of repetitive cyclical loading at 2500 microstrain in tension necessary to reduce the fatigue life of bone, based on ex vivo studies. Therefore it has been hypothesized that an intermediate bone remodeling response might play a role in the development of tibial stress fractures. In young adults tibial stress fractures are usually oblique, suggesting that they are the result of failure under shear strain. Strains were measured using surface mounted unstacked 45° rosette strain gauges on the posterior aspect of the flat medial cortex just below the tibial midshaft, in a 48year old male subject while performing vertical jumps, staircase jumps and running up and down stadium stairs. Shear strains approaching 5000 microstrain were recorded during stair jumping and vertical standing jumps. Shear strains above 1250 microstrain were recorded during runs up and down stadium steps. Based on predictions from ex vivo studies, stair and vertical jumping tibial shear strain in the test subject was high enough to potentially produce tibial stress fracture subsequent to repetitive cyclic loading without necessarily requiring an intermediate remodeling response to microdamage. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty.

    PubMed

    Inoue, Shinji; Akagi, Masao; Asada, Shigeki; Mori, Shigeshi; Zaima, Hironori; Hashida, Masahiko

    2016-09-01

    Medial tibial condylar fractures (MTCFs) are a rare but serious complication after unicompartmental knee arthroplasty. Although some surgical pitfalls have been reported for MTCFs, it is not clear whether the varus/valgus tibial inclination contributes to the risk of MTCFs. We constructed a 3-dimensional finite elemental method model of the tibia with a medial component and assessed stress concentrations by changing the inclination from 6° varus to 6° valgus. Subsequently, we repeated the same procedure adding extended sagittal bone cuts of 2° and 10° in the posterior tibial cortex. Furthermore, we calculated the bone volume that supported the tibial component, which is considered to affect stress distribution in the medial tibial condyle. Stress concentrations were observed on the medial tibial metaphyseal cortices and on the anterior and posterior tibial cortices in the corner of cut surfaces in all models; moreover, the maximum principal stresses on the posterior cortex were larger than those on the anterior cortex. The extended sagittal bone cuts in the posterior tibial cortex increased the stresses further at these 3 sites. In the models with a 10° extended sagittal bone cut, the maximum principal stress on the posterior cortex increased as the tibial inclination changed from 6° varus to 6° valgus. The bone volume decreased as the inclination changed from varus to valgus. In this finite element method, the risk of MTCFs increases with increasing valgus inclination of the tibial component and with increased extension of the sagittal cut in the posterior tibial cortex. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging.

    PubMed

    Karimi, Elham; Norouzian, Mohsen; Birjandinejad, Ali; Zandi, Reza; Makhmalbaf, Hadi

    2017-11-01

    Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which affects knee joint stability. Posterior tibial slope has impact on flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the mechanical and anatomical axis is important. The aim of this study was to evaluate the value of posterior tibial slope in medial and lateral compartments of tibial plateau and to assess the relationship among the slope with age, gender and other variables of tibial plateau surface. This descriptive study was conducted on 132 healthy knees (80 males and 52 females) with a mean age of 38.26±11.45 (20-60 years) at Imam Reza hospital in Mashhad, Iran. All patients, selected and enrolled for MRI in this study, were admitted for knee pain with uncertain clinical history. According to initial physical knee examinations the study subjects were reported healthy. The mean posterior tibial slope was 7.78± 2.48 degrees in the medial compartment and 6.85± 2.24 degrees in lateral compartment. No significant correlation was found between age and gender with posterior tibial slope ( P ≥0.05), but there was significant relationship among PTS with mediolateral width, plateau area and medial plateau. Comparison of different studies revealed that the PTS value in our study is different from other communities, which can be associated with genetic and racial factors. The results of our study are useful to PTS reconstruction in surgeries.

  15. The effect of platelet-rich plasma on osseous healing in dogs undergoing high tibial osteotomy

    PubMed Central

    Burke, Emily E.; Holmes, Shannon P.

    2017-01-01

    Objectives The purpose of this study was to investigate whether platelet-rich plasma (PRP) enhances osseous healing in conjunction with a high tibial osteotomy in dogs. Study design Randomized controlled trial. Methods Sixty-four client-owned pet dogs with naturally occurring rupture of the anterior cruciate ligament and that were to be treated with a high tibial osteotomy (tibial plateau leveling osteotomy) were randomized into the treatment or control group. Dogs in the treatment group received autologous platelet-rich plasma activated with calcium chloride and bovine thrombin to produce a well-formed PRP gel that was placed into the osteotomy at the time of surgery. Dogs in the control group received saline lavage of the osteotomy. All dogs had the osteotomy stabilized with identical titanium alloy implants and all aspects of the surgical procedure and post-operative care were identical among dogs of the two groups. Bone healing was assessed at exactly 28, 49, and 70 days after surgery with radiography and ultrasonography and with MRI at day 28. The effect of PRP on bone healing was assessed using a repeated measures analysis of covariance with radiographic and ultrasonographic data and using a t-test with the MRI data. Results Sixty dogs completed the study. There were no significant differences in age, weight, or gender distribution between the treatment and control groups. Twenty-seven dogs were treated with PRP and 33 were in the control group. The average platelet concentration of the PRP was 1.37x106 platelets/μL (±489x103) with a leukocyte concentration of 5.45x103/μL (±3.5x103). All dogs demonstrated progressive healing over time and achieved clinically successful outcomes. Time since surgery and patient age were significant predictors of radiographic healing and time since surgery was a significant predictor of ultrasonographic assessment of healing. There was no significant effect of PRP treatment as assessed radiographically, ultrasonographically

  16. A predictive factor for acquiring an ideal lower limb realignment after opening-wedge high tibial osteotomy.

    PubMed

    Bito, Haruhiko; Takeuchi, Ryohei; Kumagai, Ken; Aratake, Masato; Saito, Izumi; Hayashi, Riku; Sasaki, Yohei; Aota, Yoichi; Saito, Tomoyuki

    2009-04-01

    Obtaining a correct postoperative limb alignment is an important factor in achieving a successful clinical outcome after an opening-wedge high tibial osteotomy (OWHTO). To better predict some of the aspects that impact upon the clinical outcomes following this procedure, including postoperative correction loss and over correction, we examined the changes in the frontal plane of the lower limb in a cohort of patients who had undergone OWHTO using radiography. Forty-two knees from 33 patients (23 cases of osteoarthritis and 10 of osteonecrosis) underwent a valgus realignment OWHTO procedure and were radiographically assessed for changes that occurred pre- and post-surgery. The mean femorotibial angle (FTA) was found to be 182.1 +/- 2.0 degrees (12 +/- 2.0 anatomical varus angulation) preoperatively and 169.6 +/- 2.4 degrees (10.4 +/- 2.4 anatomical valgus angulation) postoperatively. These measurements thus revealed significant changes in the weight bearing line ratio (WBL), femoral axis angle (FA), tibial axis angle (TA), tibia plateau angle (TP), tibia vara angle (TV) and talar tilt angle (TT) following OWHTO. In contrast, no significant change was found in the weight bearing line angle (WBLA) after these treatments. To assess the relationship between the correction angle and these indexes, 42 knees were divided into the following three groups according to the postoperative FTA; a normal correction group (168 degrees < or = FTA < or = 172 degrees ), an over-correction group (FTA < 168 degrees ), and an under-correction group (FTA > 172 degrees ). There were significant differences in the delta angle [DA; calculated as (pre FTA - post FTA) - (pre TV - post TV)] among each group of patients. Our results thus indicate a negative correlation between the DA and preoperative TA (R(2) = 0.148, p < 0.05). Hence, given that the correction errors in our patients appear to negatively correlate with the preoperative TA, postoperative malalignments are likely to be predictable

  17. Anatomic tibial component design can increase tibial coverage and rotational alignment accuracy: a comparison of six contemporary designs.

    PubMed

    Dai, Yifei; Scuderi, Giles R; Bischoff, Jeffrey E; Bertin, Kim; Tarabichi, Samih; Rajgopal, Ashok

    2014-12-01

    The aim of this study was to comprehensively evaluate contemporary tibial component designs against global tibial anatomy. We hypothesized that anatomically designed tibial components offer increased morphological fit to the resected proximal tibia with increased alignment accuracy compared to symmetric and asymmetric designs. Using a multi-ethnic bone dataset, six contemporary tibial component designs were investigated, including anatomic, asymmetric, and symmetric design types. Investigations included (1) measurement of component conformity to the resected tibia using a comprehensive set of size and shape metrics; (2) assessment of component coverage on the resected tibia while ensuring clinically acceptable levels of rotation and overhang; and (3) evaluation of the incidence and severity of component downsizing due to adherence to rotational alignment and overhang requirements, and the associated compromise in tibial coverage. Differences in coverage were statistically compared across designs and ethnicities, as well as between placements with or without enforcement of proper rotational alignment. Compared to non-anatomic designs investigated, the anatomic design exhibited better conformity to resected tibial morphology in size and shape, higher tibial coverage (92% compared to 85-87%), more cortical support (posteromedial region), lower incidence of downsizing (3% compared to 39-60%), and less compromise of tibial coverage (0.5% compared to 4-6%) when enforcing proper rotational alignment. The anatomic design demonstrated meaningful increase in tibial coverage with accurate rotational alignment compared to symmetric and asymmetric designs, suggesting its potential for less intra-operative compromises and improved performance. III.

  18. The effect of proximal tibial slope on dynamic stability testing of the posterior cruciate ligament- and posterolateral corner-deficient knee.

    PubMed

    Petrigliano, Frank A; Suero, Eduardo M; Voos, James E; Pearle, Andrew D; Allen, Answorth A

    2012-06-01

    Proximal tibial slope has been shown to influence anteroposterior translation and tibial resting point in the posterior cruciate ligament (PCL)-deficient knee. The effect of proximal tibial slope on rotational stability of the knee is unknown. Change in proximal tibial slope produced via osteotomy can influence both static translation and dynamic rotational kinematics in the PCL/posterolateral corner (PLC)-deficient knee. Controlled laboratory study. Posterior drawer, dial, and mechanized reverse pivot-shift (RPS) tests were performed on hip-to-toe specimens and translation of the lateral and medial compartments measured utilizing navigation (n = 10). The PCL and structures of the PLC were then sectioned. Stability testing was repeated, and compartmental translation was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5° or -5° of tibial slope variation, after which stability testing was repeated (n = 10). Analysis was performed using 1-way analysis of variance (ANOVA; α = .05). Combined sectioning of the PCL and PLC structures resulted in a 10.5-mm increase in the posterior drawer, 15.5-mm increase in the dial test at 30°, 14.5-mm increase in the dial test at 90°, and 17.9-mm increase in the RPS (vs intact; P < .05). Increasing the posterior slope (high tibial osteotomy [HTO] +5°) in the PCL/PLC-deficient knee reduced medial compartment translation by 3.3 mm during posterior drawer (vs deficient; P < .05) but had no significant effect on the dial test at 30°, dial test at 90°, or RPS. Conversely, reversing the slope (HTO -5°) caused a 4.8-mm increase in medial compartment translation (vs deficient state; P < .05) during posterior drawer and an 8.6-mm increase in lateral compartment translation and 9.0-mm increase in medial compartment translation during RPS (vs deficient state; P < .05). Increasing posterior tibial slope diminished static posterior instability of the PCL/PLC-deficient knee as measured by the

  19. [Tibial periostitis ("medial tibial stress syndrome")].

    PubMed

    Fournier, Pierre-Etienne

    2003-06-01

    Medial tibial stress syndrome is characterised by complaints along the posteromedial tibia. Runners and athletes involved in jumping activities may develop this syndrome. Increased stress to stabilize the foot especially when excessive pronation is present explain the occurrence this lesion.

  20. Minimizing the complications of intramedullary nailing for distal third tibial shaft and metaphyseal fractures

    PubMed Central

    Yaligod, Vishwanath; Rudrappa, Girish H.; Nagendra, Srinivas; Shivanna, Umesh M.

    2013-01-01

    Background The complications of intramedullary nailing of distal third tibial shaft and metaphyseal fractures have a direct impact on ankle and hind foot function. Methods We retrospectively evaluated 28 patients. Unreamed nail was negotiated across the well reduced fracture till subchondral bone and fixed with 2 to 3 distal locking screws in different planes. Results Fracture union rate was 85%. Three out of 28 patients had malalignment. Mean ankle, hindfoot functional score was 85. Conclusion Complications can be minimized by impacting the unreamed nail till the subchondral bone while maintaining the fracture well reduced and by using multiple distal locking screws in different planes. PMID:24719527

  1. The preclinical sheep model of high tibial osteotomy relating basic science to the clinics: standards, techniques and pitfalls.

    PubMed

    Pape, Dietrich; Madry, Henning

    2013-01-01

    To develop a preclinical large animal model of high tibial osteotomy to study the effect of axial alignment on the lower extremity on specific issues of the knee joint, such as in articular cartilage repair, development of osteoarthritis and meniscal lesions. Preoperative planning, surgical procedure and postoperative care known from humans were adapted to develop a HTO model in the adult sheep. Thirty-five healthy, skeletally mature, female Merino sheep between 2 and 4 years of age underwent a HTO of their right tibia in a medial open-wedge technique inducing a normal (group 1) and an excessive valgus alignment (group 2) and a closed-wedge technique (group 3) inducing a varus alignment with the aim of elucidating the effect of limb alignment on cartilage repair in vivo. Animals were followed up for 6 months. Solid bone healing and maintenance of correction are most likely if the following surgical principles are respected: (1) medial and longitudinal approach to the proximal tibia; (2) biplanar osteotomy to increase initial rotatory stability regardless of the direction of correction; (3) small, narrow but long implant with locking screws; (4) posterior plate placement to avoid slope changes; (5) use of bicortical screws to account for the brittle bone of the tibial head and to avoid tibial head displacement. Although successful high tibial osteotomy in sheep is complex, the sheep may--because of its similarities with humans--serve as an elegant model to induce axial malalignment in a clinically relevant environment, and osteotomy healing under challenging mechanical conditions.

  2. Initial mechanical stability of cementless highly-porous titanium tibial components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stone, Timothy Brandon; Amer, Luke D; Warren, Christopher P

    Cementless fixation in total knee replacement has seen limited use since reports of early failure surfaced in the late 80s and early 90s. However the emergence of improved biomaterials, particularly porous titanium and tantalum, has led to a renewed interest in developing a cementless tibial component to enhance long-term survivorship of the implants. Cement is commonly employed to minimize micromotion in new implants but represents a weak interface between the implant and bone. The elimination of cement and application of these new biomaterials, which theoretically provide improved stability and ultimate osseointegration, would likely result in greater knee replacement success. Additionally,more » the removal of cement from the procedure would help minimize surgical durations and get rid of the time needed for curing, thereby the chance of infection. The purpose of this biomechanical study was twofold. The first goal was to assess whether vibration analysis techniques can be used to evaluate and characterize initial mechanical stability of cementless implants more accurately than the traditional method of micromotion determination, which employs linear variable differential transducers (LVDTs). Second, an evaluative study was performed to determine the comparative mechanical stability of five designs of cementless tibial components under mechanical loading designed to simulate in vivo forces. The test groups will include a cemented Triathlon Keeled baseplate control group, three different 2-peg cementless baseplates with smooth, mid, and high roughnesses and a 4-peg cement/ess baseplate with mid-roughness.« less

  3. Distinct hip and rearfoot kinematics in female runners with a history of tibial stress fracture.

    PubMed

    Milner, Clare E; Hamill, Joseph; Davis, Irene S

    2010-02-01

    Cross-sectional controlled laboratory study. To investigate the kinematics of the hip, knee, and rearfoot in the frontal and transverse planes in female distance runners with a history of tibial stress fracture. Tibial stress fractures are a common overuse injury in runners, accounting for up to half of all stress fractures. Abnormal kinematics of the lower extremity may contribute to abnormal musculoskeletal load distributions, leading to an increased risk of stress fractures. Thirty female runners with a history of tibial stress fracture were compared to 30 age-matched and weekly-running-distance-matched control subjects with no previous lower extremity bony injuries. Kinematic and kinetic data were collected using a motion capture system and a force platform, respectively, as subjects ran in the laboratory. Selected variables of interest were compared between the groups using a multivariate analysis of variance (MANOVA). Peak hip adduction and peak rearfoot eversion angles were greater in the stress fracture group compared to the control group. Peak knee adduction and knee internal rotation angles and all joint angles at impact peak were similar between the groups. Runners with a previous tibial stress fracture exhibited greater peak hip adduction and rearfoot eversion angles during the stance phase of running compared to healthy controls. A consequence of these mechanics may be altered load distribution within the lower extremity, predisposing individuals to stress fracture.

  4. Management of tibial non-unions according to a novel treatment algorithm.

    PubMed

    Ferreira, Nando; Marais, Leonard Charles

    2015-12-01

    Tibial non-unions represent a spectrum of conditions that are challenging to treat. The optimal management remains unclear despite the frequency with which these diagnoses are encountered. The aim of this study was to determine the outcome of tibial non-unions managed according to a novel tibial non-union treatment algorithm. One hundred and eighteen consecutive patients with 122 uninfected tibial non-unions were treated according to our proposed tibial non-union treatment algorithm. All patients were followed-up clinically and radiologically for a minimum of six months after external fixator removal. Four patients were excluded because they did not complete the intended treatment process. The final study population consisted of 94 men and 24 women with a mean age of 34 years. Sixty-seven non-unions were stiff hypertrophic, 32 mobile atrophic, 16 mobile oligotrophic and one true pseudoarthrosis. Six non-unions were classified as type B1 defect non-unions. Bony union was achieved after the initial surgery in 113/122 (92.6%) tibias. Nine patients had failure of treatment. Seven persistent non-unions were successfully retreated according to the tibial non-union treatment algorithm. This resulted in final bony union in 120/122 (98.3%) tibias. The proposed tibial non-union treatment algorithm appears to produce high union rates across a diverse group of tibial non-unions. Tibial non-unions however, remain difficult to treat and should be referred to specialist units where advanced reconstructive techniques are practiced on a regular basis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Arthroscopic repair of the posterior horn of the medial meniscus with opening wedge high tibial osteotomy: surgical technique.

    PubMed

    Jung, Kwang Am; Kim, Sung Jae; Lee, Su Chan; Jeong, Jae Hoon; Song, Moon Bok; Lee, Choon Key

    2009-07-01

    Simultaneous repair of a radial tear at the tibial attachment site of the posterior horn of the medial meniscus under special circumstances requiring tibial valgus osteotomy is technically difficult. First, most patients who need an osteotomy have a narrowed medial tibiofemoral joint space. In such a situation, the pull-out suture technique is more difficult to perform than in a normal joint space. Second, pulling out suture strands that penetrate the posterior horn of the medial meniscus to the anterior tibial cortex increases the risk of transection during osteotomy. We performed a meniscus repair combined with an opening wedge tibial valgus osteotomy without complications and present our technique as a new method for use in selective cases necessitating both meniscus repair of a complete radial tear and opening wedge tibial osteotomy.

  6. [Application of tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty].

    PubMed

    Li, Guoliang; Han, Guangpu; Zhang, Jinxiu; Ma, Shiqiang; Guo, Donghui; Yuan, Fulu; Qi, Bingbing; Shen, Runbin

    2013-07-01

    To explore the application value of self-made tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty (TKA) for improving the lower extremity force line. Between January and August 2012, 13 cases (21 knees) of osteoarthritis with tibial extra-articular deformity were treated, including 5 males (8 knees) and 8 females (13 knees) with an average age of 66.5 years (range, 58-78 years). The disease duration was 2-5 years (mean, 3.5 years). The knee society score (KSS) was 45.5 +/- 15.5. Extra-articular deformities included 1 case of knee valgus (2 knees) and 12 cases of knee varus (19 knees). Preoperative full-length X-ray films of lower extremities showed 10-21 degrees valgus or varus deformity of tibial extra joint. Self-made tibial mechanical axis locator was used to determine and mark coronal tibial mechanical axis under X-ray before TKA, and then osteotomy was performed with extramedullary positioning device according to the mechanical axis marker.' All incisions healed by first intention, without related complications of infection and joint instability. All patients were followed up 5-12 months (mean, 8.3 months). The X-ray examination showed < 2 degrees knee deviation angle in the others except 1 case of 2.9 degrees knee deviation angle at 3 days after operation, and the accurate rate was 95.2%. No loosening or instability of prosthesis occurred during follow-up. KSS score was 85.5 +/- 15.0 at last follow-up, showing significant difference when compared with preoperative score (t=12.82, P=0.00). The seft-made tibial mechanical axis locator can improve the accurate rate of the lower extremity force line in TKA for tibia extra-articular deformity.

  7. The risk of revision in total knee arthroplasty is not affected by previous high tibial osteotomy

    PubMed Central

    Badawy, Mona; Fenstad, Anne M; Indrekvam, Kari; Havelin, Leif I; Furnes, Ove

    2015-01-01

    Background and purpose — Previous studies have found different outcomes after revision of knee arthroplasties performed after high tibial osteotomy (HTO). We evaluated the risk of revision of total knee arthroplasty with or without previous HTO in a large registry material. Patients and methods — 31,077 primary TKAs were compared with 1,399 TKAs after HTO, using Kaplan-Meier 10-year survival percentages and adjusted Cox regression analysis. Results — The adjusted survival analyses showed similar survival in the 2 groups. The Kaplan-Meier 10-year survival was 93.8% in the primary TKA group and 92.6% in the TKA-post-HTO group. Adjusted RR was 0.97 (95% CI: 0.77–1.21; p = 0.8). Interpretation — In this registry-based study, previous high tibial osteotomy did not appear to compromise the results regarding risk of revision after total knee arthroplasty compared to primary knee arthroplasty. PMID:26058747

  8. Maximizing tibial coverage is detrimental to proper rotational alignment.

    PubMed

    Martin, Stacey; Saurez, Alex; Ismaily, Sabir; Ashfaq, Kashif; Noble, Philip; Incavo, Stephen J

    2014-01-01

    Traditionally, the placement of the tibial component in total knee arthroplasty (TKA) has focused on maximizing coverage of the tibial surface. However, the degree to which maximal coverage affects correct rotational placement of symmetric and asymmetric tibial components has not been well defined and might represent an implant design issue worthy of further inquiry. Using four commercially available tibial components (two symmetric, two asymmetric), we sought to determine (1) the overall amount of malrotation that would occur if components were placed for maximal tibial coverage; and (2) whether the asymmetric designs would result in less malrotation than the symmetric designs when placed for maximal coverage in a computer model using CT reconstructions. CT reconstructions of 30 tibial specimens were used to generate three-dimensional tibia reconstructions with attention to the tibial anatomic axis, the tibial tubercle, and the resected tibial surface. Using strict criteria, four commercially available tibial designs (two symmetric, two asymmetric) were placed on the resected tibial surface. The resulting component rotation was examined. Among all four designs, 70% of all tibial components placed in orientation maximizing fit to resection surface were internally malrotated (average 9°). The asymmetric designs had fewer cases of malrotation (28% and 52% for the two asymmetric designs, 100% and 96% for the two symmetric designs; p < 0.001) and less malrotation on average (2° and 5° for the asymmetric designs, 14° for both symmetric designs; p < 0.001). Maximizing tibial coverage resulted in implant malrotation in a large percentage of cases. Given similar amounts of tibial coverage, correct rotational positioning was more likely to occur with the asymmetric designs. Malrotation of components is an important cause of failure in TKA. Priority should be given to correct tibial rotational positioning. This study suggested that it is easier to balance rotation and

  9. Forefoot-rearfoot coupling patterns and tibial internal rotation during stance phase of barefoot versus shod running.

    PubMed

    Eslami, Mansour; Begon, Mickaël; Farahpour, Nader; Allard, Paul

    2007-01-01

    Based on twisted plate and mitered hinge models of the foot and ankle, forefoot-rearfoot coupling motion patterns can contribute to the amount of tibial rotation. The present study determined the differences of forefoot-rearfoot coupling patterns as well as excessive excursion of tibial internal rotation in shod versus barefoot conditions during running. Sixteen male subjects ran 10 times at 170 steps per minute under the barefoot and shod conditions. Forefoot-rearfoot coupling motions were assessed by measuring mean relative phase angle during five intervals of stance phase for the main effect of five time intervals and two conditions (ANOVA, P<0.05). Tibial internal rotation excursion was compared between the shod and barefoot conditions over the first 50% of stance phase using paired t-test, (P<0.05). Forefoot adduction/abduction and rearfoot eversion/inversion coupling motion patterns were significantly different between the conditions and among the intervals (P<0.05; effect size=0.47). The mean absolute relative angle was significantly modified to 37 degrees in-phase relationship at the heel-strike of running with shoe wears. No significant differences were noted in the tibial internal rotation excursion between shod and barefoot conditions. Significant variations in the forefoot adduction/abduction and rearfoot eversion/inversion coupling patterns could have little effect on the amount of tibial internal rotation excursion. Yet it remains to be determined whether changes in the frontal plane forefoot-rearfoot coupling patterns influence the tibia kinematics for different shoe wears or foot orthotic interventions. The findings question the rational for the prophylactic use of forefoot posting in foot orthoses.

  10. Assessment of tibial rotation and meniscal movement using kinematic magnetic resonance imaging

    PubMed Central

    2014-01-01

    Objective This work aimed to assess tibial rotations, meniscal movements, and morphological changes during knee flexion and extension using kinematic magnetic resonance imaging (MRI). Methods Thirty volunteers with healthy knees were examined using kinematic MRI. The knees were imaged in the transverse plane with flexion and extension angles from 0° to 40° and 40° to 0°, respectively. The tibial interior and exterior rotation angles were measured, and the meniscal movement range, height change, and side movements were detected. Results The tibia rotated internally (11.55° ± 3.20°) during knee flexion and rotated externally (11.40° ± 3.0°) during knee extension. No significant differences were observed between the internal and external tibial rotation angles (P > 0.05), between males and females (P > 0.05), or between the left and right knee joints (P > 0.05). The tibial rotation angle with a flexion angle of 0° to 24° differed significantly from that with a flexion angle of 24° to 40° (P < 0.01). With knee flexion, the medial and lateral menisci moved backward and the height of the meniscus increased. The movement range was greater in the anterior horn than in the posterior horn and greater in the lateral meniscus than in the medial meniscus (P < 0.01). During backward movements of the menisci, the distance between the anterior and posterior horns decreased, with the decrease more apparent in the lateral meniscus (P < 0.01). The side movements of the medial and lateral menisci were not obvious, and a smaller movement range was found than that of the forward and backward movements. Conclusion Knee flexion and extension facilitated internal and external tibial rotations, which may be related to the ligament and joint capsule structure and femoral condyle geometry. PMID:25142267

  11. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    PubMed

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  12. Management of combined knee medial compartmental and patellofemoral osteoarthritis with lateral closing wedge osteotomy with anterior translation of the distal tibial fragment: Does the degree of anteriorization affect the functional outcome and posterior tibial slope?

    PubMed

    Sadek, Ahmed F; Osman, Mohammed K; Laklok, Mohamed A

    2016-10-01

    The aim of this study was to assess the effect of degree of anterior translation of the distal tibial fragment after lateral closing wedge high tibial osteotomy in patients having combined knee medial compartmental and patellofemoral osteoarthritis. A retrospective study was conducted on 64 patients who were operated on for combined knee medial compartmental and patellofemoral osteoarthritis, by lateral closing wedge high tibial osteotomy with anterior translation of the distal tibial fragment. They were divided into two groups; Group I comprising 32 patients (34 knees, mean age of 51.4±7years) whose degree of anterior translation was <1cm and Group II comprising 32 patients (33 knees, mean age of 52.2±8.3years) whose degree of anterior translation was >1.5cm. The final assessment was performed via: visual analog scale, postoperative Knee Society clinical rating system function score, active range of motion, time to union, degree of correction of mechanical axis, posterior tibial slope, and Insall-Salvati ratio. Group II patients exhibited statistically superior mean postoperative score and better return to their work than Group I (P=0.013, 0.076, respectively). Both groups showed statistically significant differences between the preoperative and postoperative evaluation parameters (P<0.001). The posterior tibial slope was decreased in both groups but with no significant difference (P=0.527). Lateral closing wedge high tibial osteotomy combined with anterior translation of the distal tibial fragment more than 1.5cm achieved significantly better postoperative functional knee score. Both groups exhibited comparatively decreased posterior tibial slope. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Incidence and epidemiology of tibial shaft fractures.

    PubMed

    Larsen, Peter; Elsoe, Rasmus; Hansen, Sandra Hope; Graven-Nielsen, Thomas; Laessoe, Uffe; Rasmussen, Sten

    2015-04-01

    The literature lacks recent population-based epidemiology studies of the incidence, trauma mechanism and fracture classification of tibial shaft fractures. The purpose of this study was to provide up-to-date information on the incidence of tibial shaft fractures in a large and complete population and report the distribution of fracture classification, trauma mechanism and patient baseline demographics. Retrospective reviews of clinical and radiological records. A total of 196 patients were treated for 198 tibial shaft fractures in the years 2009 and 2010. The mean age at time of fracture was 38.5 (21.2SD) years. The incidence of tibial shaft fracture was 16.9/100,000/year. Males have the highest incidence of 21.5/100,000/year and present with the highest frequency between the age of 10 and 20, whereas women have a frequency of 12.3/100,000/year and have the highest frequency between the age of 30 and 40. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. The majority of tibial shaft fractures occur during walking, indoor activity and sports. The distribution among genders shows that males present a higher frequency of fractures while participating in sports activities and walking. Women present the highest frequency of fractures while walking and during indoor activities. This study shows an incidence of 16.9/100,000/year for tibial shaft fractures. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Tibial component considerations in bicruciate-retaining total knee arthroplasty: A 3D MRI evaluation of proximal tibial anatomy.

    PubMed

    Saxena, Vishal; Anari, Jason B; Ruutiainen, Alexander T; Voleti, Pramod B; Stephenson, Jason W; Lee, Gwo-Chin

    2016-08-01

    Restoration of normal anatomy and proper ligament balance are theoretical prerequisites for reproducing physiological kinematics with bicruciate-retaining total knee arthroplasty (TKA). The purpose of this study was to use a 3D MRI technique to evaluate the topography of the proximal tibia and outline considerations in tibial component design for bicruciate-retaining TKA. We identified 100 consecutive patients (50 males and 50 females) between ages 20 and 40 years with knee MRIs without arthritis, dysplasia, ACL tears, or prior knee surgery. A novel 3D MRI protocol coordinating axial, coronal, and sagittal images was used to measure: 1) medial and lateral posterior tibial slopes; 2) medial and lateral coronal slopes; and 3) distance from the anterior tibia to the ACL footprint. There was no overall difference in medial and lateral posterior tibial slopes (5.5° (95% CI 5.0 to 6.0°) vs. 5.4° (95% CI 4.8 to 6.0°), respectively (p=0.80)), but 41 patients had side-to-side differences greater than 3°. The medial coronal slope was greater than the lateral coronal slope (4.6° (95% CI 4.0 to 5.1°) vs. 3.3° (95% CI 2.9 to 3.7°), respectively (p<0.0001)). Females had less clearance between the anterior tibia and ACL footprint than males (10.8mm (95% CI 10.4 to 11.2mm) vs. 13.0mm (95% CI 12.5 to 13.5mm), respectively (p<0.0001)). Due to highly variable proximal tibial topography, a monoblock bicruciate-retaining tibial baseplate may not reproduce normal anatomy in all patients. Level IV - Anatomic research study. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Contact Kinematics Correlates to Tibial Component Migration Following Single Radius Posterior Stabilized Knee Replacement.

    PubMed

    Teeter, Matthew G; Perry, Kevin I; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-03-01

    Contact kinematics between total knee arthroplasty components is thought to affect implant migration; however, the interaction between kinematics and tibial component migration has not been thoroughly examined in a modern implant system. A total of 24 knees from 23 patients undergoing total knee arthroplasty with a single radius, posterior stabilized implant were examined. Patients underwent radiostereometric analysis at 2 and 6 weeks, 3 and 6 months, and 1 and 2 years to measure migration of the tibial component in all planes. At 1 year, patients also had standing radiostereometric analysis examinations acquired in 0°, 20°, 40°, and 60° of flexion, and the location of contact and magnitude of any condylar liftoff was measured for each flexion angle. Regression analysis was performed between kinematic variables and migration at 1 year. The average magnitude of maximum total point motion across all patients was 0.671 ± 0.270 mm at 1 year and 0.608 ± 0.359 mm at 2 years (P = .327). Four implants demonstrated continuous migration of >0.2 mm between the first and second year of implantation. There were correlations between the location of contact and tibial component anterior-posterior tilt, varus-valgus tilt, and anterior-posterior translation. The patients with continuous migration demonstrated atypical kinematics and condylar liftoff in some instances. Kinematics can influence tibial component migration, likely through alterations of force transmission. Abnormal kinematics may play a role in long-term implant loosening. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Tanaka, Sakae

    2016-01-01

    Bone cutting error can be one of the causes of malalignment in unicompartmental knee arthroplasty (UKA). The amount of cutting error in total knee arthroplasty has been reported. However, none have investigated cutting error in UKA. The purpose of this study was to reveal the amount of cutting error in UKA when open cutting guide was used and clarify whether cutting the tibia horizontally twice using the same cutting guide reduced the cutting errors in UKA. We measured the alignment of the tibial cutting guides, the first-cut cutting surfaces and the second cut cutting surfaces using the navigation system in 50 UKAs. Cutting error was defined as the angular difference between the cutting guide and cutting surface. The mean absolute first-cut cutting error was 1.9° (1.1° varus) in the coronal plane and 1.1° (0.6° anterior slope) in the sagittal plane, whereas the mean absolute second-cut cutting error was 1.1° (0.6° varus) in the coronal plane and 1.1° (0.4° anterior slope) in the sagittal plane. Cutting the tibia horizontally twice reduced the cutting errors in the coronal plane significantly (P<0.05). Our study demonstrated that in UKA, cutting the tibia horizontally twice using the same cutting guide reduced cutting error in the coronal plane. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Fractures of the Tibial Plateau Involve Similar Energies as the Tibial Pilon but Greater Articular Surface Involvement

    PubMed Central

    Dibbern, Kevin; Kempton, Laurence B.; Higgins, Thomas F.; Morshed, Saam; McKinley, Todd O.; Marsh, J. Lawrence; Anderson, Donald D.

    2016-01-01

    Patients with tibial pilon fractures have a higher incidence of post-traumatic osteoarthritis than those with fractures of the tibial plateau. This may indicate that pilon fractures present a greater mechanical insult to the joint than do plateau fractures. We tested the hypothesis that fracture energy and articular fracture edge length, two independent indicators of severity, are higher in pilon than plateau fractures. We also evaluated if clinical fracture classification systems accurately reflect severity. Seventy-five tibial plateau fractures and fifty-two tibial pilon fractures from a multi-institutional study were selected to span the spectrum of severity. Fracture severity measures were calculated using objective CT-based image analysis methods. The ranges of fracture energies measured for tibial plateau and pilon fractures were 3.2 to 33.2 Joules (J) and 3.6 to 32.2 J, respectively, and articular fracture edge lengths were 68.0 to 493.0 mm and 56.1 to 288.6 mm, respectively. There were no differences in the fracture energies between the two fracture types, but plateau fractures had greater articular fracture edge lengths (p<0.001). The clinical fracture classifications generally reflected severity, but there was substantial overlap of fracture severity measures between different classes. Clinical Significance Similar fracture energies with different degrees of articular surface involvement suggest a possible explanation for dissimilar rates of post-traumatic osteoarthritis for fractures of the tibial plateau compared to the tibial pilon. The substantial overlap of severity measures between different fracture classes may well have confounded prior clinical studies relying on fracture classification as a surrogate for severity. PMID:27381653

  18. [Magnetic resonance imaging of tibial periostitis].

    PubMed

    Meyer, X; Boscagli, G; Tavernier, T; Aczel, F; Weber, F; Legros, R; Charlopain, P; Martin, J P

    1998-01-01

    Tibial periostitis frequently occurs in athletes. We present our experience with MRI in a series of 7 patients (11 legs) with this condition. The clinical presentation and scintigraphic scanning suggested the diagnosis. MRI exploration of 11 legs demonstrated a high band-like juxta-osseous signal enhancement of SE and IR T2 weighted sequences in 6 cases, a signal enhancement after i.v. contrast administration in 4. Tibial periostitis is a clinical diagnosis and MRI and scintigraphic findings can be used to assure the differential diagnosis in difficult cases with stress fracture. MRI can visualize juxta-osseous edematous and inflammatory reactions and an increased signal would appear to be characteristic when the band-like image is fixed to the periosteum.

  19. Trifurcation of the tibial nerve within the tarsal tunnel.

    PubMed

    Develi, Sedat

    2018-05-01

    The tibial nerve is the larger terminal branch of the sciatic nerve and it terminates in the tarsal tunnel by giving lateral and medial plantar nerves. We present a rare case of trifurcation of the tibial nerve within the tarsal tunnel. The variant nerve curves laterally after branching from the tibial nerve and courses deep to quadratus plantae muscle. Interestingly, posterior tibial artery was also terminating by giving three branches. These branches were accompanying the terminal branches of the tibial nerve.

  20. Tibial shaft fractures in football players

    PubMed Central

    Chang, Winston R; Kapasi, Zain; Daisley, Susan; Leach, William J

    2007-01-01

    Background Football is officially the most popular sport in the world. In the UK, 10% of the adult population play football at least once a year. Despite this, there are few papers in the literature on tibial diaphyseal fractures in this sporting group. In addition, conflicting views on the nature of this injury exist. The purpose of this paper is to compare our experience of tibial shaft football fractures with the little available literature and identify any similarities and differences. Methods and Results A retrospective study of all tibial football fractures that presented to a teaching hospital was undertaken over a 5 year period from 1997 to 2001. There were 244 tibial fractures treated. 24 (9.8%) of these were football related. All patients were male with a mean age of 23 years (range 15 to 29) and shin guards were worn in 95.8% of cases. 11/24 (45.8%) were treated conservatively, 11/24 (45.8%) by Grosse Kemp intramedullary nail and 2/24 (8.3%) with plating. A difference in union times was noted, conservative 19 weeks compared to operative group 23.9 weeks (p < 0.05). Return to activity was also different in the two groups, conservative 27.6 weeks versus operative 23.3 weeks (p < 0.05). The most common fracture pattern was AO Type 42A3 in 14/24 (58.3%). A high number 19/24 (79.2%) were simple transverse or short oblique fractures. There was a low non-union rate 1/24 (4.2%) and absence of any open injury in our series. Conclusion Our series compared similarly with the few reports available in the literature. However, a striking finding noted by the authors was a drop in the incidence of tibial shaft football fractures. It is likely that this is a reflection of recent compulsory FIFA regulations on shinguards as well as improvements in the design over the past decade since its introduction. PMID:17567522

  1. Early weight bearing versus delayed weight bearing in medial opening wedge high tibial osteotomy: a randomized controlled trial.

    PubMed

    Lansdaal, Joris Radboud; Mouton, Tanguy; Wascher, Daniel Charles; Demey, Guillaume; Lustig, Sebastien; Neyret, Philippe; Servien, Elvire

    2017-12-01

    The need for a period of non-weight bearing after medial opening wedge high tibial osteotomy remains controversial. It is hypothesized that immediate weight bearing after medial opening wedge high tibial osteotomy would have no difference in functional scores at one year compared to delayed weight bearing. Fifty patients, median age 54 years (range 40-65), with medial compartment osteoarthritis, underwent a medial opening wedge high tibial osteotomy utilizing a locking plate without bone grafting. Patients were randomized into an Immediate or a Delayed (2 months) weight bearing group. All patients were assessed at one-year follow-up and the two groups compared. The primary outcome measure was the IKS score. Secondary outcome measures included the IKDC score, the VAS pain score and rate of complications. The functional scores significantly improved in both groups. The IKS score increased from 142 ± 31 to 171 ± 26 in the Immediate group (p < 0.001) and from 148 ± 22 to 178 ± 23 in the Delayed group (p < 0.001). The IKDC score increased from 49 ± 17 pre-operatively to 68 ± 14 one-year post-operatively in the Immediate group (p < 0.0001) and from 44 ± 16 to 69 ± 19 in the Delayed group (p < 0.001). The average VAS for pain 2 months after surgery was 3 ± 3 in the Immediate group and 3 ± 2 in the Delayed (n.s.). There was no significant difference between the two groups in any of the outcome measures. The mean mechanical femorotibial angle changed from 6° of varus (0°-15° of varus, SD = 3°) to 4° of valgus (5°-11° of valgus, SD = 3°) in the Immediate group and from 5° of varus (0°-10° of varus, SD = 3°) to 3° of valgus (2° of varus to 8° of valgus, SD = 3°) in the Delayed group. No difference was seen between groups, and no loss of correction was observed in any patient. Two cases of non-union occurred, one in each group. One infection and one deep vein thrombosis occurred in the Immediate group. Immediate

  2. Outcomes of Surgical Treatment for Anterior Tibial Stress Fractures in Athletes: A Systematic Review.

    PubMed

    Chaudhry, Zaira S; Raikin, Steven M; Harwood, Marc I; Bishop, Meghan E; Ciccotti, Michael G; Hammoud, Sommer

    2017-12-01

    Although most anterior tibial stress fractures heal with nonoperative treatment, some may require surgical management. To our knowledge, no systematic review has been conducted regarding surgical treatment strategies for the management of chronic anterior tibial stress fractures from which general conclusions can be drawn regarding optimal treatment in high-performance athletes. This systematic review was conducted to evaluate the surgical outcomes of anterior tibial stress fractures in high-performance athletes. Systematic review; Level of evidence, 4. In February 2017, a systematic review of the PubMed, MEDLINE, Cochrane, SPORTDiscus, and CINAHL databases was performed to identify studies that reported surgical outcomes for anterior tibial stress fractures. Articles meeting the inclusion criteria were screened, and reported outcome measures were documented. A total of 12 studies, published between 1984 and 2015, reporting outcomes for the surgical treatment of anterior tibial stress fractures were included in this review. All studies were retrospective case series. Collectively, surgical outcomes for 115 patients (74 males; 41 females) with 123 fractures were evaluated in this review. The overall mean follow-up was 23.3 months. The most common surgical treatment method reported in the literature was compression plating (n = 52) followed by drilling (n = 33). Symptom resolution was achieved in 108 of 123 surgically treated fractures (87.8%). There were 32 reports of complications, resulting in an overall complication rate of 27.8%. Subsequent tibial fractures were reported in 8 patients (7.0%). Moreover, a total of 17 patients (14.8%) underwent a subsequent procedure after their initial surgery. Following surgical treatment for anterior tibial stress fracture, 94.7% of patients were able to return to sports. The available literature indicates that surgical treatment of anterior tibial stress fractures is associated with a high rate of symptom resolution and return

  3. The use of a robotic tibial rotation device and an electromagnetic tracking system to accurately reproduce the clinical dial test.

    PubMed

    Stinton, S K; Siebold, R; Freedberg, H; Jacobs, C; Branch, T P

    2016-03-01

    The purpose of this study was to: (1) determine whether a robotic tibial rotation device and an electromagnetic tracking system could accurately reproduce the clinical dial test at 30° of knee flexion; (2) compare rotation data captured at the footplates of the robotic device to tibial rotation data measured using an electromagnetic sensor on the proximal tibia. Thirty-two unilateral ACL-reconstructed patients were examined using a robotic tibial rotation device that mimicked the dial test. The data reported in this study is only from the healthy legs of these patients. Torque was applied through footplates and was measured using servomotors. Lower leg motion was measured at the foot using the motors. Tibial motion was also measured through an electromagnetic tracking system and a sensor on the proximal tibia. Load-deformation curves representing rotational motion of the foot and tibia were compared using Pearson's correlation coefficients. Off-axis motions including medial-lateral translation and anterior-posterior translation were also measured using the electromagnetic system. The robotic device and electromagnetic system were able to provide axial rotation data and translational data for the tibia during the dial test. Motion measured at the foot was not correlated to motion of the tibial tubercle in internal rotation or in external rotation. The position of the tibial tubercle was 26.9° ± 11.6° more internally rotated than the foot at torque 0 Nm. Medial-lateral translation and anterior-posterior translation were combined to show the path of the tubercle in the coronal plane during tibial rotation. The information captured during a manual dial test includes both rotation of the tibia and proximal tibia translation. All of this information can be captured using a robotic tibial axial rotation device with an electromagnetic tracking system. The pathway of the tibial tubercle during tibial axial rotation can provide additional information about knee

  4. Change in gait after high tibial osteotomy: A systematic review and meta-analysis.

    PubMed

    Lee, Seung Hoon; Lee, O-Sung; Teo, Seow Hui; Lee, Yong Seuk

    2017-09-01

    We conducted a meta-analysis to analyze how high tibial osteotomy (HTO) changes gait and focused on the following questions: (1) How does HTO change basic gait variables? (2) How does HTO change the gait variables in the knee joint? Twelve articles were included in the final analysis. A total of 383 knees was evaluated. There were 237 open wedge (OW) and 143 closed wedge (CW) HTOs. There were 4 level II studies and 8 level III studies. All studies included gait analysis and compared pre- and postoperative values. One study compared CWHTO and unicompartmental knee arthroplasty (UKA), and another study compared CWHTO and OWHTO. Five studies compared gait variables with those of healthy controls. One study compared operated limb gait variables with those in the non-operated limb. Gait speed, stride length, knee adduction moment, and lateral thrust were major variables assessed in 2 or more studies. Walking speed increased and stride length was increased or similar after HTO compared to the preoperative value in basic gait variables. Knee adduction moment and lateral thrust were decreased after HTO compared to the preoperative knee joint gait variables. Change in co-contraction of the medial side muscle after surgery differed depending on the degree of frontal plane alignment. The relationship between change in knee adduction moment and change in mechanical axis angle was controversial. Based on our systematic review and meta-analysis, walking speed and stride length increased after HTO. Knee adduction moment and lateral thrust decreased after HTO compared to the preoperative values of gait variables in the knee joint. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Motion at the Tibial and Polyethylene Component Interface in a Mobile-Bearing Total Ankle Replacement.

    PubMed

    Lundeen, Gregory A; Clanton, Thomas O; Dunaway, Linda J; Lu, Minggen

    2016-08-01

    Normal biomechanics of the ankle joint includes sagittal as well as axial rotation. Current understanding of mobile-bearing motion at the tibial-polyethylene interface in total ankle arthroplasty (TAA) is limited to anterior-posterior (AP) motion of the polyethylene component. The purpose of our study was to define the motion of the polyethylene component in relation to the tibial component in a mobile-bearing TAA in both the sagittal and axial planes in postoperative patients. Patients who were a minimum of 12 months postoperative from a third-generation mobile-bearing TAA were identified. AP images were saved at maximum internal and external rotation, and the lateral images were saved in maximum plantarflexion and dorsiflexion. Sagittal range of motion and AP translation of the polyethylene component were measured from the lateral images. Axial rotation was determined by measuring the relative position of the 2 wires within the polyethylene component on AP internal and external rotation imaging. This relationship was compared to a table developed from fluoroscopic images taken at standardized degrees of axial rotation of a nonimplanted polyethylene with the associated length relationship of the 2 imbedded wires. Sixteen patients were included in this investigation, 9 (56%) were male and average age was 68 (range, 49-80) years. Time from surgery averaged 25 (range, 12-38) months. Total sagittal range of motion averaged 23±9 (range, 9-33) degrees. Axial motion for total internal and external rotation of the polyethylene component on the tibial component averaged 6±5 (range, 0-18) degrees. AP translation of the polyethylene component relative to the tibial component averaged 1±1 (range, 0-3) mm. There was no relationship between axial rotation or AP translation of the polyethylene component and ankle joint range of motion (P > .05). To our knowledge, this is the first investigation to measure axial and sagittal motion of the polyethylene component at the tibial

  6. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge.

    PubMed

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-07-01

    Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient patients during lunge exercise.

  7. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge

    PubMed Central

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-01-01

    Background: Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. Objectives: In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. Patients and Methods: For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results: Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Conclusion: Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient

  8. Histological analysis of the tibial anterior cruciate ligament insertion.

    PubMed

    Oka, Shinya; Schuhmacher, Peter; Brehmer, Axel; Traut, Ulrike; Kirsch, Joachim; Siebold, Rainer

    2016-03-01

    This study was performed to investigate the morphology of the tibial anterior cruciate ligament (ACL) by histological assessment. The native (undissected) tibial ACL insertion of six fresh-frozen cadaveric knees was cut into four sagittal sections parallel to the long axis of the medial tibial spine. For histological evaluation, the slices were stained with haematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analysed at a magnification of 20×. The anterior tibial ACL insertion was bordered by a bony anterior ridge. The most medial ACL fibres inserted from the medial tibial spine and were adjacent to the articular cartilage of the medial tibial plateau. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact with the lateral part of the tibial ACL insertion. A small fat pad was located just posterior to the functional ACL fibres. The anterior-posterior length of the medial ACL insertion was an average of 10.8 ± 1.1 mm compared with the lateral, which was only 6.2 ± 1.1 mm (p < 0.001). There were no central or posterolateral inserting ACL fibres. The shape of the bony tibial ACL insertion was 'duck-foot-like'. In contrast to previous findings, the functional mid-substance fibres arose from the most posterior part of the 'duck-foot' in a flat and 'c-shaped' way. The most anterior part of the tibial ACL insertion was bordered by a bony anterior ridge and the most medial by the medial tibial spine. No posterolateral fibres nor ACL bundles have been found histologically. This histological investigation may improve our understanding of the tibial ACL insertion and may provide important information for anatomical ACL reconstruction.

  9. Effect of open wedge high tibial osteotomy on the lateral tibiofemoral compartment in sheep. Part II: standard and overcorrection do not cause articular cartilage degeneration.

    PubMed

    Ziegler, Raphaela; Goebel, Lars; Cucchiarini, Magali; Pape, Dietrich; Madry, Henning

    2014-07-01

    To evaluate whether medial open wedge high tibial osteotomy (HTO) results in structural changes in the articular cartilage in the lateral tibiofemoral compartment of adult sheep. Three experimental groups received biplanar osteotomies of the right proximal tibiae: (a) closing wedge HTO (4.5° of tibial varus), (b) opening wedge HTO (4.5° tibial valgus; standard correction), and (c) opening wedge HTO (9.5° of valgus; overcorrection), each of which was compared to the contralateral knees that only received an arthrotomy. After 6 months, the macroscopic and microscopic characteristics of the articular cartilage of the lateral tibiofemoral compartment were assessed. The articular cartilage in the central region of the lateral tibial plateau in sheep had a higher safranin O staining intensity and was 4.6-fold thicker than in the periphery (covered by the lateral meniscus). No topographical variation in the type-II collagen immunoreactivity was seen. All lateral tibial plateaus showed osteoarthritic changes in regions not covered by the lateral meniscus. No osteoarthritis was seen in the peripheral submeniscal regions of the lateral tibial plateau and the lateral femoral condyle. Opening wedge HTO resulting in both standard and overcorrection was not associated with significant macroscopic and microscopic structural changes between groups in the articular cartilage of the lateral tibial plateau and femoral condyle after 6 months in vivo. Opening wedge HTO resulting in both standard and overcorrection is a safe procedure for the articular cartilage in an intact lateral tibiofemoral compartment of adult sheep at 6 months postoperatively.

  10. Do modern total knee replacements improve tibial coverage?

    PubMed

    Meier, Malin; Webb, Jonathan; Collins, Jamie E; Beckmann, Johannes; Fitz, Wolfgang

    2018-01-25

    The purpose of the present study is to compare newer designs of various symmetric and asymmetric tibial components and measure tibial bone coverage using the rotational safe zone defined by two commonly utilized anatomic rotational landmarks. Computed tomography scans (CT scans) of one hundred consecutive patients scheduled for total knee arthroplasty were obtained pre-operatively. A virtual proximal tibial cut was performed and two commonly used rotational axes were added for each image: the medio-lateral axis (ML-axis) and the medial 1/3 tibial tubercle axis (med-1/3-axis). Different symmetric and asymmetric implant designs were then superimposed in various rotational positions for best cancellous and cortical coverage. The images were imported to a public domain imaging software, and cancellous and cortical bone coverage was computed for each image, with each implant design in various rotational positions. One single implant type could not be identified that provided the best cortical and cancellous coverage of the tibia, irrespective of using the med-1/3-axis or the ML-axis for rotational alignment. However, it could be confirmed that the best bone coverage was dependent on the selected rotational landmark. Furthermore, improved bone coverage was observed when tibial implant positions were optimized between the two rotational axes. Tibial coverage is similar for symmetric and asymmetric designs, but depends on the rotational landmark for which the implant is designed. The surgeon has the option to improve tibial coverage by optimizing placement between the two anatomic rotational alignment landmarks, the medial 1/3 and the ML-axis. Surgeons should be careful assessing intraoperative rotational tibial placement using the described anatomic rotational landmarks to optimize tibial bony coverage without compromising patella tracking. III.

  11. Preserving the PCL during the tibial cut in total knee arthroplasty.

    PubMed

    Cinotti, G; Sessa, P; Amato, M; Ripani, F R; Giannicola, G

    2017-08-01

    Previous studies have shown that the PCL insertion may be damaged during the tibial cut performed in total knee arthroplasty. We investigated the maximum thickness of a tibial cut that preserves the PCL insertion and to what extent the posterior slope of the tibial cut and that of the patient's tibial plateaus affect the outcome. MR images of 83 knees were analysed. The maximum thickness of a tibial cut that preserves the PCL using a posterior slope of 0°, 3°, 5° and parallel to the patient's slope of the tibial plateau, was evaluated. Correlations between the results and the degrees of the posterior slope of the patient's tibial plateaus were also investigated. The maximum thickness of a tibial cut that preserves the entire PCL insertion was, on average, 5.5, 4.7, 4.2 and 3.1 mm when a posterior slope of 0°, 3°, 5° and parallel to the patients' tibial plateaus was used, respectively. When the 25th percentile was considered, the maximum thickness of a tibial cut that preserved the PCL was 4 and 3 mm with a tibial cut of 0° and 5° of posterior slope, respectively. The maximum thickness of a tibial cut that preserved the PCL was significantly greater in patients with a sagittal slope of the tibial plateaus more than 8° than in those with a sagittal slope less than 8°. In cruciate retaining implants, the PCL insertion may be spared in the majority of patients by performing a tibial cut of 4 mm, or even less when a posterior slope of 3°-5° is used. The clinical relevance of our study is that the execution of a conservative tibial cut, followed by a second tibial resection to achieve the thickness required for the tibial component to be implanted, may be an alternative technique to spare the PCL in CR TKA. II.

  12. Bypass grafting to the anterior tibial artery.

    PubMed

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  13. Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty

    PubMed Central

    2011-01-01

    Background and purpose The choice of either all-polyethylene (AP) tibial components or metal-backed (MB) tibial components in total knee arthroplasty (TKA) remains controversial. We therefore performed a meta-analysis and systematic review of randomized controlled trials that have evaluated MB and AP tibial components in primary TKA. Methods The search strategy included a computerized literature search (Medline, EMBASE, Scopus, and the Cochrane Central Register of Controlled Trials) and a manual search of major orthopedic journals. A meta-analysis and systematic review of randomized or quasi-randomized trials that compared the performance of tibial components in primary TKA was performed using a fixed or random effects model. We assessed the methodological quality of studies using Detsky quality scale. Results 9 randomized controlled trials (RCTs) published between 2000 and 2009 met the inclusion quality standards for the systematic review. The mean standardized Detsky score was 14 (SD 3). We found that the frequency of radiolucent lines in the MB group was significantly higher than that in the AP group. There were no statistically significant differences between the MB and AP tibial components regarding component positioning, knee score, knee range of motion, quality of life, and postoperative complications. Interpretation Based on evidence obtained from this study, the AP tibial component was comparable with or better than the MB tibial component in TKA. However, high-quality RCTs are required to validate the results. PMID:21895503

  14. Physeal growth arrest after tibial lengthening in achondroplasia

    PubMed Central

    2012-01-01

    Background and purpose Bilateral tibial lengthening has become one of the standard treatments for upper segment-lower segment disproportion and to improve quality of life in achondroplasia. We determined the effect of tibial lengthening on the tibial physis and compared tibial growth that occurred at the physis with that in non-operated patients with acondroplasia. Methods We performed a retrospective analysis of serial radiographs until skeletal maturity in 23 achondroplasia patients who underwent bilateral tibial lengthening before skeletal maturity (lengthening group L) and 12 achondroplasia patients of similar height and age who did not undergo tibial lengthening (control group C). The mean amount of lengthening of tibia in group L was 9.2 cm (lengthening percentage: 60%) and the mean age at the time of lengthening was 8.2 years. The mean duration of follow-up was 9.8 years. Results Skeletal maturity (fusion of physis) occurred at 15.2 years in group L and at 16.0 years in group C. The actual length of tibia (without distraction) at skeletal maturity was 238 mm in group L and 277 mm in group C (p = 0.03). The mean growth rates showed a decrease in group L relative to group C from about 2 years after surgery. Physeal closure was most pronounced on the anterolateral proximal tibial physis, with relative preservation of the distal physis. Interpretation Our findings indicate that physeal growth rate can be disturbed after tibial lengthening in achondroplasia, and a close watch should be kept for such an occurrence—especially when lengthening of more than 50% is attempted. PMID:22489887

  15. Role of Joshi's external stabilization system with percutaneous screw fixation in high-energy tibial condylar fractures associated with severe soft tissue injuries.

    PubMed

    Gupta, Ashish-Kumar; Sapra, Rahul; Kumar, Rakesh; Gupta, Som-Prakash; Kaushik, Devwart; Gaba, Sahil; Bansal, Mahesh Chand; Dayma, Ratan Lal

    2015-01-01

    The treatment of high-energy tibial condylar fractures which are associated with severe soft tissue injuries remains contentious and challenging. In this study, we assessed the results of Joshi's external stabilization system (JESS) by using the principle of ligamentotaxis and percutaneous screw fixation for managing high-energy tibial condylar fractures associated with severe soft tissue injuries. Between June 2008 and June 2010, 25 consecutive patients who were 17e71 years (mean, 39.7), underwent the JESS fixation for high-energy tibial condylar fractures associated with severe soft tissue injuries. Out of 25 patients, 2 were lost during follow-up and in 1 case early removal of frame was done, leaving 22 cases for final follow-up. Among them, 11 had poor skin condition with abrasions and blisters and 2 were open injuries (Gustilo-Anderson grade I&II). The injury mechanisms were motor vehicle accidents (n=19), fall from a height (n=2) and assault (n=1). The fractures were classified according to Schatzker classification system. There were 7 type-V, 14 type-VI and 1 type-lV Schatzker's tibial plateau fractures. The average interval between the injury and surgery was 6.8 days (range 2-13). The average hospital stay was 13 days (range, 7-22). The average interval between the surgery and full weight bearing was 13.6 weeks (range 11-20). The average range of knee flexion was 121°(range 105°-135°). The normal extension of the knee was observed in 20 patients, and an extensor lag of 5°-8° was noted in 2 patients. The complications included superficial pin tract infections (n=4) with no knee stiffness. JESS with lag screw fixation combines the benefit of traction, external fixation, and limited internal fixation, at the same time as allowing the ease of access to the soft tissue for wound checks, pin care, dressing changes, measurement of compartment pressure, and the monitoring of the neurovascular status. In a nutshell, JESS along with screw fixation offers a

  16. Failure at the Tibial Cement-Implant Interface With the Use of High-Viscosity Cement in Total Knee Arthroplasty.

    PubMed

    Kopinski, Judith E; Aggarwal, Ajay; Nunley, Ryan M; Barrack, Robert L; Nam, Denis

    2016-11-01

    Recent literature has shown debonding of the tibial implant-cement interface as a potential cause for implant loosening. The purpose of this case series is to report this phenomenon in a historically well-performing implant when used with high-viscosity cement (HVC). Thirteen primary cemented Biomet Vanguard total knee arthroplasties were referred to 1 of 2 institutions with complaints of persistent pain after their index procedure. A radiographic and infectious work-up was completed for each patient. All 13 patients underwent a revision of the index surgery with intraoperative diagnosis of tibial component debonding at the implant-cement interface. HVC (Cobalt, DJO Surgical, Vista, CA and Depuy HVC; Depuy Inc, Warsaw, IN) was used in all index cases. The average time to revision surgery for the 13 patients was 2.7 ± 1.9 years from the index surgery. Laboratory infectious markers were within normal in most cases, and all intra-articular aspirations showed no bacterial, fungal, or anaerobic growth. Eleven of 13 patients showed no radiographic evidence of loosening; however, all cases demonstrated tibial component debonding intraoperatively. Given our institution's experience and previously reported data demonstrating excellent survivorship with this total knee arthroplasty prosthesis, we propose that the early failures seen in this case series may be associated with the use of HVC cement. In the setting of a negative infectious work-up and no radiographic evidence to suggest loosening, the surgeon should consider debonding of the tibial component as a potential cause for persistent pain if HVC cement was used with this prosthetic design. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Treatment of segmental tibial fractures with supercutaneous plating.

    PubMed

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  18. Anterior Cruciate Ligament Reconstruction with Tibial Attachment Preserving Hamstring Graft without Implant on Tibial Side

    PubMed Central

    Sinha, Skand; Naik, Ananta Kumar; Maheshwari, Mridul; Sandanshiv, Sumedh; Meena, Durgashankar; Arya, Rajendra K

    2018-01-01

    Background: Tibial attachment preserving hamstring graft could prevent potential problems of free graft in anterior cruciate ligament (ACL) reconstruction such as pull out before graft-tunnel healing or rupture before ligamentization. Different implants have been reportedly used for tibial side fixation with this technique. We investigated short-term outcome of ACL reconstruction (ACLR) with tibial attachment sparing hamstring graft without implant on the tibial side by outside in technique. Materials and Methods: Seventy nine consecutive cases of ACL tear having age of 25.7 ± 6.8 years were included after Institutional Board Approval. All subjects were male. The mean time interval from injury to surgery was of 7.5 ± 6.4 months. Hamstring tendons were harvested with open tendon stripper leaving the tibial insertion intact. The free ends of the tendons were whip stitched, quadrupled, and whip stitched again over the insertion site of hamstring with fiber wire (Arthrex). Single bundle ACLR was done by outside in technique and the femoral tunnel was created with cannulated reamer. The graft was pulled up to the external aperture of femoral tunnel and fixed with interference screw (Arthrex). The scoring was done by Lysholm, Tegner, and KT 1000 by independent observers. All cases were followed up for 2 years. Results: The mean length of quadrupled graft attached to tibia was 127.65 ± 7.5 mm, and the mean width was 7.52 ± 0.78 mm. The mean preoperative Lysholm score of 47.15 ± 9.6, improved to 96.8 ± 2.4 at 1 year. All cases except two returned to the previous level of activity after ACLR. There was no significant difference statistically between preinjury (5.89 ± 0.68) and postoperative (5.87 ± 0.67) Tegner score. The anterior tibial translation (ATT) (KT 1000) improved from 11.44 ± 1.93 mm to 3.59 ± 0.89 mm. The ATT of operated knee returned to nearly the similar value as of the opposite knee (3.47 ± 1.16 mm). The Pivot shift test was negative in all cases

  19. Reliability of image-free navigation to monitor lower-limb alignment.

    PubMed

    Pearle, Andrew D; Goleski, Patrick; Musahl, Volker; Kendoff, Daniel

    2009-02-01

    Proper alignment of the mechanical axis of the lower limb is the principal goal of a high tibial osteotomy. A well-accepted and relevant technical specification is the coronal plane lower-limb alignment. Target values for coronal plane alignment after high tibial osteotomy include 2 degrees of overcorrection, while tolerances for this specification have been established as 2 degrees to 4 degrees. However, the role of axial plane and sagittal plane realignment after high tibial osteotomy is poorly understood; consequently, targets and tolerance for this technical specification remain undefined. This article reviews the literature concerning the reliability and precision of navigation in monitoring the clinically relevant specification of lower-limb alignment in high tibial osteotomy. We conclude that image-free navigation registration may be clinically useful for intraoperative monitoring of the coronal plane only. Only fair and poor results for the axial and sagittal planes can be obtained by image-free navigation systems. In the future, combined image-based data, such as those from radiographs, magnetic resonance imaging, and gait analysis, may be used to help to improve the accuracy and reproducibility of quantitative intraoperative monitoring of lower-limb alignment.

  20. Bone microarchitecture of the tibial plateau in skeletal health and osteoporosis.

    PubMed

    Krause, Matthias; Hubert, Jan; Deymann, Simon; Hapfelmeier, Alexander; Wulff, Birgit; Petersik, Andreas; Püschel, Klaus; Amling, Michael; Hawellek, Thelonius; Frosch, Karl-Heinz

    2018-05-07

    Impaired bone structure poses a challenge for the treatment of osteoporotic tibial plateau fractures. As knowledge of region-specific structural bone alterations is a prerequisite to achieving successful long-term fixation, the aim of the current study was to characterize tibial plateau bone structure in patients with osteoporosis and the elderly. Histomorphometric parameters were assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT) in 21 proximal tibiae from females with postmenopausal osteoporosis (mean age: 84.3 ± 4.9 years) and eight female healthy controls (45.5 ± 6.9 years). To visualize region-specific structural bony alterations with age, the bone mineral density (Hounsfield units) was additionally analyzed in 168 human proximal tibiae. Statistical analysis was based on evolutionary learning using globally optimal regression trees. Bone structure deterioration of the tibial plateau due to osteoporosis was region-specific. Compared to healthy controls (20.5 ± 4.7%) the greatest decrease in bone volume fraction was found in the medio-medial segments (9.2 ± 3.5%, p < 0.001). The lowest bone volume was found in central segments (tibial spine). Trabecular connectivity was severely reduced. Importantly, in the anterior and posterior 25% of the lateral and medial tibial plateaux, trabecular support and subchondral cortical bone thickness itself were also reduced. Thinning of subchondral cortical bone and marked bone loss in the anterior and posterior 25% of the tibial plateau should require special attention when osteoporotic patients require fracture fixation of the posterior segments. This knowledge may help to improve the long-term, fracture-specific fixation of complex tibial plateau fractures in osteoporosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Bilateral double level tibial lengthening in dwarfism.

    PubMed

    Burghardt, Rolf D; Yoshino, Koichi; Kashiwagi, Naoya; Yoshino, Shigeo; Bhave, Anil; Paley, Dror; Herzenberg, John E

    2015-12-01

    Outcome assessment after double level tibial lengthening in patients with dwarfism. Fourteen patients with dwarfism were analyzed after bilateral simultaneous double level tibial lengthening. Average age was 15.1 years. Average lengthening was 13.5 cm. The two levels were lengthened by an average of 7.5 cm proximally and 6.0 cm distally. Concomitant deformities were also addressed during lengthening. External fixation treatment time averaged 8.8 months. Healing index averaged 0.7 months/cm. Bilateral tibial lengthening for dwarfism is difficult, but the results are usually quite gratifying.

  2. Proximal tibial osteotomy. A survivorship analysis.

    PubMed

    Ritter, M A; Fechtman, R A

    1988-01-01

    Proximal tibial osteotomy is generally accepted as a treatment for the patient with unicompartmental arthritis. However, a few reports of the long-term results of this procedure are available in the literature, and none have used the technique known as survivorship analysis. This technique has an advantage over conventional analysis because it does not exclude patients for inadequate follow-up, loss to follow-up, or patient death. In this study, survivorship analysis was applied to 78 proximal tibial osteotomies, performed exclusively by the senior author for the correction of a preoperative varus deformity, and a survival curve was constructed. It was concluded that the reliable longevity of the proximal tibial osteotomy is approximately 6 years.

  3. Compartment syndrome after tibial plateau fracture☆

    PubMed Central

    Pitta, Guilherme Benjamin Brandão; dos Santos, Thays Fernanda Avelino; dos Santos, Fernanda Thaysa Avelino; da Costa Filho, Edelson Moreira

    2014-01-01

    Fractures of the tibial plateau are relatively rare, representing around 1.2% of all fractures. The tibia, due to its subcutaneous location and poor muscle coverage, is exposed and suffers large numbers of traumas, not only fractures, but also crush injuries and severe bruising, among others, which at any given moment, could lead compartment syndrome in the patient. The case is reported of a 58-year-old patient who, following a tibial plateau fracture, presented compartment syndrome of the leg and was submitted to decompressive fasciotomy of the four right compartments. After osteosynthesis with internal fixation of the tibial plateau using an L-plate, the patient again developed compartment syndrome. PMID:26229779

  4. Patella height is not altered by descending medial open-wedge high tibial osteotomy (HTO) compared to ascending HTO.

    PubMed

    Krause, Matthias; Drenck, Tobias Claus; Korthaus, Alexander; Preiss, Achim; Frosch, Karl-Heinz; Akoto, Ralph

    2018-06-01

    The primary purpose of the study was to gain insight into geometric changes of the patellar height (PH) and posterior tibial slope (PTS) after a biplanar ascending medial open-wedge high tibial osteotomy (HTO) compared to biplanar descending medial open-wedge HTO in patients with genu varum. Sixty-four patients (mean age 45.2 ± 8.7 years, females n = 24, males n = 40) with varus malalignment and medial gonarthrosis were retrospectively studied. Patients received either a biplanar ascending or descending medial open-wedge HTO. Radiographic analysis included the assessment of standing total leg axis, PH, and PTS prior to and after surgery. In the ascending HTO group, PH decreased significantly by 4.0% (p = 0.037, Caton-Deschamps index) after an average leg axis valgus-producing correction of 7.1° ± 2.8°. In the descending HTO group, with an average leg axis correction of 7.0° ± 3.7°, there were no significant PH changes. There were no significant differences between the ascending and descending HTO groups regarding PTS or leg axis. The mean post-operative leg axis between ascending (1.6° ± 1.9°) and descending HTO (1.9° ± 2.4°) was not significantly different. Compared to the biplanar ascending medial open-wedge HTO, the descending HTO did not influence patella height or increase the posterior tibial slope. In order to respect patellofemoral and slope-related knee kinematics, a biplanar descending medial open-wedge HTO has proven useful to control patella height and posterior tibial slope. These findings underscore the importance of the preoperative patella height assessment in the osteotomy planning and subsequent choice of the biplanar osteotomy direction. IV.

  5. Tibial lengthening over intramedullary nails

    PubMed Central

    Burghardt, R. D.; Manzotti, A.; Bhave, A.; Paley, D.

    2016-01-01

    Objectives The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. Methods In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group. Results The mean external fixation time for the LON group was 2.6 months and for the matched case group was 7.6 months. The mean lengthening amounts for the LON and the matched case groups were 5.2 cm and 4.9 cm, respectively. The radiographic consolidation time in the LON group was 6.6 months and in the matched case group 7.6 months. Using a clinical and radiographic outcome score that was designed for this study, the outcome was determined to be excellent in 17 and good in two patients for the LON group. The outcome was excellent in 14 and good in five patients in the matched case group. The LON group had increased blood loss and increased cost. The LON group had four deep infections; the matched case group did not have any deep infections. Conclusions The outcomes in the LON group were comparable with the outcomes in the matched case group. The LON group had a shorter external fixation time but experienced increased blood loss, increased cost, and four cases of deep infection. The advantage of reducing external fixation treatment time may outweigh these disadvantages in patients who have a healthy soft-tissue envelope. Cite this article: J. E. Herzenberg. Tibial lengthening over intramedullary nails: A matched case comparison with Ilizarov tibial lengthening. Bone Joint Res 2016;5:1–10. doi: 10.1302/2046-3758.51.2000577 PMID:26764351

  6. The location of the tibial accelerometer does influence impact acceleration parameters during running.

    PubMed

    Lucas-Cuevas, Angel Gabriel; Encarnación-Martínez, Alberto; Camacho-García, Andrés; Llana-Belloch, Salvador; Pérez-Soriano, Pedro

    2017-09-01

    Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s -1 with three accelerometers attached with double-sided tape and tightened to the participants' tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.

  7. Functional outcome of Schatzker type V and VI tibial plateau fractures treated with dual plates

    PubMed Central

    Prasad, G Thiruvengita; Kumar, T Suresh; Kumar, R Krishna; Murthy, Ganapathy K; Sundaram, Nandkumar

    2013-01-01

    Background: Dual plate fixation in comminuted bicondylar tibial plateau fractures remains controversial. Open reduction and internal fixation, specifically through compromised soft tissues, has historically been associated with major wound complications. Alternate methods of treatment have been described, each with its own merits and demerits. We performed a retrospective study to evaluate the functional outcome of lateral and medial plate fixation of Schatzker type V and VI fractures through an anterolateral approach, and a medial minimally invasive approach or a posteromedial approach. Materials and Methods: We treated 46 tibial plateau fractures Schatzker type V and VI with lateral and medial plates through an anterolateral approach and a medial minimal invasive approach over an 8 years period. Six patients were lost to followup. Radiographs in two planes were taken in all cases. Immediate postoperative radiographs were assessed for quality of reduction and fixation. The functional outcome was evaluated according to the Oxford Knee Score criteria on followup. Results: Forty patients (33 men and 7 women) who completed the followup were included in the study. There were 20 Schatzker type V fractures and 20 Schatzker type VI fractures. The mean duration of followup was 4 years (range 1-8 years). All patients had a satisfactory articular reduction defined as ≤2 mm step-off or gap as assessed on followup. All patients had a good coronal and sagittal plane alignment, and articular width as assessed on supine X-rays of the knee in the anteroposterior (AP) and lateral views. The functional outcome, as assessed by the Oxford Knee Score, was excellent in 30 patients and good in 10 patients. All patients returned to their pre-injury level of activity and employment. There were no instances of deep infection. Conclusions: Dual plate fixation of severe bicondylar tibial plateau fractures is an excellent treatment option as it provides rigid fixation and allows early knee

  8. High Frequency High Spectral Resolution Focal Plane Arrays for AtLAST

    NASA Astrophysics Data System (ADS)

    Baryshev, Andrey

    2018-01-01

    Large collecting area single dish telescope such as ATLAST will be especially effective for medium (R 1000) and high (R 50000) spectral resolution observations. Large focal plane array is a natural solution to increase mapping speed. For medium resolution direct detectors with filter banks (KIDs) and or heterodyne technology can be employed. We will analyze performance limits of comparable KID and SIS focal plane array taking into account quantum limit and high background condition of terrestrial observing site. For large heterodyne focal plane arrays, a high current density AlN junctions open possibility of large instantaneous bandwidth >40%. This and possible multi frequency band FPSs presents a practical challenge for spatial sampling and scanning strategies. We will discuss phase array feeds as a possible solution, including a modular back-end system, which can be shared between KID and SIS based FPA. Finally we will discuss achievable sensitivities and pixel co unts for a high frequency (>500 GHz) FPAs and address main technical challenges: LO distribution, wire counts, bias line multiplexing, and monolithic vs. discrete mixer component integration.

  9. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty.

    PubMed

    Tanikake, Yohei; Hayashi, Koji; Ogawa, Munehiro; Inagaki, Yusuke; Kawate, Kenji; Tomita, Tetsuya; Tanaka, Yasuhito

    2016-12-01

    A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  10. Predictive formula for the length of tibial tunnel in anterior crucitate ligament reconstruction.

    PubMed

    Chernchujit, Bancha; Barthel, Thomas

    2009-12-01

    The anterior cruciate ligament (ACL) reconstruction using bone-patellar tendon bone graft is a common procedure in orthopedics. One challenging problem found is a graft-tunnel mismatch. Previous studies have reported the mathematic formula to predict the tibial angle length and angle to avoid graft-tunnel mismatch but these formulas have shown limited predictability. To propose a predictive formula for the length of tibial tunnel and to examine its predictability. Thirty six patients (26 males, 14 females) with ACL injury were included in this study. The preoperativemedial proximal tibial angle was measured. Intraoperatively, the tibial tunnel length and tibial entry point were measured. The postoperative coronal and saggital angle of tibial tunnel were measured from knee radiograph. The data were analysed by using trigonometry correlation and formulate the predictive formula of tibial tunnel length. We found that tibial tunnel length (T) has trigonometric correlation between the location of tibial tunnel entry point (w), coronal angle of tibial tunnel (b), saggital angle of tibial tunnel (a) and the medial proximal tibial slope (c) by using this formula T = Wcos(c)tan(b)/sin(a) This proposed predictive formula can well predict the length of the tibial tunnel at preoperative period to avoid graft-tunnel mismatch.

  11. Models of tibial fracture healing in normal and Nf1-deficient mice.

    PubMed

    Schindeler, Aaron; Morse, Alyson; Harry, Lorraine; Godfrey, Craig; Mikulec, Kathy; McDonald, Michelle; Gasser, Jürg A; Little, David G

    2008-08-01

    Delayed union and nonunion are common complications associated with tibial fractures, particularly in the distal tibia. Existing mouse tibial fracture models are typically closed and middiaphyseal, and thus poorly recapitulate the prevailing conditions following surgery on a human open distal tibial fracture. This report describes our development of two open tibial fracture models in the mouse, where the bone is broken either in the tibial midshaft (mid-diaphysis) or in the distal tibia. Fractures in the distal tibial model showed delayed repair compared to fractures in the tibial midshaft. These tibial fracture models were applied to both wild-type and Nf1-deficient (Nf1+/-) mice. Bone repair has been reported to be exceptionally problematic in human NF1 patients, and these patients can also spontaneously develop tibial nonunions (known as congenital pseudarthrosis of the tibia), which are recalcitrant to even vigorous intervention. pQCT analysis confirmed no fundamental differences in cortical or cancellous bone in Nf1-deficient mouse tibiae compared to wild-type mice. Although no difference in bone healing was seen in the tibial midshaft fracture model, the healing of distal tibial fractures was found to be impaired in Nf1+/- mice. The histological features associated with nonunited Nf1+/- fractures were variable, but included delayed cartilage removal, disproportionate fibrous invasion, insufficient new bone anabolism, and excessive catabolism. These findings imply that the pathology of tibial pseudarthrosis in human NF1 is complex and likely to be multifactorial.

  12. Shape optimization of tibial prosthesis components

    NASA Technical Reports Server (NTRS)

    Saravanos, D. A.; Mraz, P. J.; Davy, D. T.

    1993-01-01

    NASA technology and optimal design methodologies originally developed for the optimization of composite structures (engine blades) are adapted and applied to the optimization of orthopaedic knee implants. A method is developed enabling the shape tailoring of the tibial components of a total knee replacement implant for optimal interaction within the environment of the tibia. The shape of the implant components are optimized such that the stresses in the bone are favorably controlled to minimize bone degradation, to improve the mechanical integrity of the implant/interface/bone system, and to prevent failures of the implant components. A pilot tailoring system is developed and the feasibility of the concept is demonstrated and evaluated. The methodology and evolution of the existing aerospace technology from which this pilot optimization code was developed is also presented and discussed. Both symmetric and unsymmetric in-plane loading conditions are investigated. The results of the optimization process indicate a trend toward wider and tapered posts as well as thicker backing trays. Unique component geometries were obtained for the different load cases.

  13. Proximal tibial fracture following anterior cruciate ligament reconstruction surgery: a biomechanical analysis of the tibial tunnel as a stress riser.

    PubMed

    Aldebeyan, Wassim; Liddell, Antony; Steffen, Thomas; Beckman, Lorne; Martineau, Paul A

    2017-08-01

    This is the first biomechanical study to examine the potential stress riser effect of the tibial tunnel or tunnels after ACL reconstruction surgery. In keeping with literature, the primary hypothesis tested in this study was that the tibial tunnel acts as a stress riser for fracture propagation. Secondary hypotheses were that the stress riser effect increases with the size of the tunnel (8 vs. 10 mm), the orientation of the tunnel [standard (STT) vs. modified transtibial (MTT)], and with the number of tunnels (1 vs. 2). Tibial tunnels simulating both single bundle hamstring graft (8 mm) and bone-patellar tendon-bone graft (10 mm) either STT or MTT position, as well as tunnels simulating double bundle (DB) ACL reconstruction (7, 6 mm), were drilled in fourth-generation saw bones. These five experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure on a Materials Testing System to simulate tibial plateau fracture. There were no statistically significant differences in peak load to failure between any of the groups, including the control group. The fracture occurred through the tibial tunnel in 100 % of the MTT tunnels (8 and 10 mm) and 80 % of the DB tunnels specimens; however, the fractures never (0 %) occurred through the tibial tunnel of the standard tunnels (8 or 10 mm) (P = 0.032). In the biomechanical model, the tibial tunnel does not appear to be a stress riser for fracture propagation, despite suggestions to the contrary in the literature. Use of a standard, more vertical tunnel decreases the risk of ACL graft compromise in the event of a fracture. This may help to inform surgical decision making on ACL reconstruction technique.

  14. Adverse event rates and classifications in medial opening wedge high tibial osteotomy.

    PubMed

    Martin, Robin; Birmingham, Trevor B; Willits, Kevin; Litchfield, Robert; Lebel, Marie-Eve; Giffin, J Robert

    2014-05-01

    Previously reported complications in medial opening wedge (MOW) high tibial osteotomy (HTO) vary considerably in both rate and severity. (1) To determine the rates of adverse events in MOW HTO classified into different grades of severity based on the treatments required and (2) to compare patient-reported outcomes between the different adverse event classifications. Case series; Level of evidence, 4. All patients receiving MOW HTO at a single medical center from 2005 to 2009 were included. Internal fixation was used in all cases, with either a nonlocking (Puddu) or locking (Tomofix) plate. Patients were evaluated at 2, 6, and 12 weeks; 6 and 12 months; and annually thereafter. Types of potential surgical and postoperative adverse events, categorized into 3 classes of severity based on the subsequent treatments, were defined a priori. Medical records and radiographs were then reviewed by an independent observer. The Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared in subgroups of patients based on the categories of adverse events observed. A total of 323 consecutive procedures (242 males) were evaluated (age, mean ± standard deviation, 46 ± 9 years; body mass index, mean ± standard deviation, 30 ± 5 kg/m(2)). Adverse events requiring no additional treatment (class 1) were undisplaced lateral cortical breaches (20%), displaced (>2 mm) lateral hinge fracture (6%), delayed wound healing (6%), undisplaced lateral tibial plateau fracture (3%), hematoma (3%), and increased tibial slope ≥10° (1%). Adverse events requiring additional or extended nonoperative management (class 2) were delayed union (12%), cellulitis (10%), limited hardware failure (1 broken screw; 4%), postoperative stiffness (1%), deep vein thrombosis (1%), and complex regional pain syndrome (CRPS) type 1 (1%). Adverse events requiring additional or revision surgery and/or long-term medical care (class 3) were aseptic nonunion (3%), deep infection (2%), CRPS type

  15. Anatomy and classification of the posterior tibial fragment in ankle fractures.

    PubMed

    Bartoníček, Jan; Rammelt, Stefan; Kostlivý, Karel; Vaněček, Václav; Klika, Daniel; Trešl, Ivo

    2015-04-01

    The aim of this study was to analyze the pathoanatomy of the posterior fragment on the basis of a comprehensive CT examination, including 3D reconstructions, in a large patient cohort. One hundred and forty one consecutive individuals with an ankle fracture or fracture-dislocation of types Weber B or Weber C and evidence of a posterior tibial fragment in standard radiographs were included in the study. The mean patient age was 49 years (range 19-83 years). The exclusion criteria were patients below 18 years of age, inability to provide written consent, fractures of the tibial pilon, posttraumatic arthritis and pre-existing deformities. In all patients, post-injury radiographs were obtained in anteroposterior, mortise and lateral views. All patients underwent CT scanning in transverse, sagittal and frontal planes. 3D CT reconstruction was performed in 91 patients. We were able to classify 137 cases into one of the following four types with constant pathoanatomic features: type 1: extraincisural fragment with an intact fibular notch, type 2: posterolateral fragment extending into the fibular notch, type 3: posteromedial two-part fragment involving the medial malleolus, type 4: large posterolateral triangular fragment. In the 4 cases it was not possible to classify the type of the posterior tibial fragment. These were collectively termed type 5 (irregular, osteoporotic fragments). It is impossible to assess the shape and size of the posterior malleolar fragment, involvement of the fibular notch, or the medial malleolus, on the basis of plain radiographs. The system that we propose for classification of fractures of the posterior malleolus is based on CT examination and takes into account the size, shape and location of the fragment, stability of the tibio-talar joint and the integrity of the fibular notch. It may be a useful indication for surgery and defining the most useful approach to these injuries.

  16. Load Sharing Among Collateral Ligaments, Articular Surfaces, and the Tibial Post in Constrained Condylar Knee Arthroplasty.

    PubMed

    Wang, Xiaonan; Malik, Aamer; Bartel, Donald L; Wright, Timothy M; Padgett, Douglas E

    2016-08-01

    The normal knee joint maintains stable motion during activities of daily living. After total knee arthroplasty (TKA), stability is achieved by the conformity of the bearing surfaces of the implant components, ligaments, and constraint structures incorporated in the implant design. The large, rectangular tibial post in constrained condylar knee (CCK) arthroplasty, often used in revision surgery, provides added stability, but increases susceptibility to polyethylene wear as it contacts the intercondylar box on the femoral component. We examined coronal plane stability to understand the relative contributions of the mechanisms that act to stabilize the CCK knee under varus-valgus loading, namely, load distribution between the medial and lateral condyles, contact of the tibial post with the femoral intercondylar box, and elongation of the collateral ligaments. A robot testing system was used to determine the joint stability in human cadaveric knees as described by the moment versus angular rotation behavior under varus-valgus moments at 0 deg, 30 deg, and 90 deg of flexion. The angular rotation of the CCK knee in response to the physiological moments was limited to ≤1.5 deg. The primary stabilizing mechanism was the redistribution of the contact force on the bearing surfaces. Contact between the tibial post and the femoral box provided a secondary stabilizing mechanism after lift-off of a condyle had occurred. Collateral ligaments provide limited stability because little ligament elongation occurred under such small angular rotations. Compressive loads applied across the knee joint, such as would occur with the application of muscle forces, enhanced the ability of the bearing surfaces to provide resisting internal varus-valgus moment and, thus, reduced the exposure of the tibial post to the external varus-valgus loads. Our results suggest that the CCK stability can be refined by considering both the geometry of the bearing surfaces and the contacting geometry

  17. Ideal tibial intramedullary nail insertion point varies with tibial rotation.

    PubMed

    Walker, Richard M; Zdero, Rad; McKee, Michael D; Waddell, James P; Schemitsch, Emil H

    2011-12-01

    The aim of the study was to investigate how superior entry point varies with tibial rotation and to identify landmarks that can be used to identify suitable radiographs for successful intramedullary nail insertion. The proximal tibia and knee were imaged for 12 cadaveric limbs undergoing 5° increments of internal and external rotation. Medial and lateral arthrotomies were performed, the ideal superior entry point was identified, and a 2-mm Kirschner wire inserted. A second Kirschner wire was sequentially placed at the 5-mm and then the 10-mm position, both medial and lateral to the initial Kirschner wire. Radiographs of the knee were obtained for all increments. The changing position of the ideal nail insertion point was recorded. A 30° arc (range, 25°-40°) provided a suitable anteroposterior radiograph. On the neutral anteroposterior radiograph, the Kirschner wire was 54% ± 1.5% (range, 51-56%) from the medial edge of the tibial plateau. For every 5° of rotation, the Kirschner wire moved 3% of the plateau width. During external rotation, a misleading medial entry point was obtained. A fibular bisector line correlated with an entry point that was ideal or up to 5 mm lateral to this but never medial. The film that best showed the fibular bisector line was between 0° and 10° of internal rotation of the tibia. The fibula head bisector line can be used to avoid choosing external rotation views and, thus, avoid medial insertion points. The current results may help the surgeon prevent malalignment during intramedullary nailing in proximal tibial fractures.

  18. Tibial Stress Injuries: Decisive Diagnosis and Treatment of "Shin Splints."

    ERIC Educational Resources Information Center

    Couture, Christopher J.; Karlson, Kristine A.

    2002-01-01

    Tibial stress injuries, commonly called shin splints, often result when bone remodeling processes adopt inadequately to repetitive stress. Physicians who are caring for athletic patients must have a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are…

  19. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    PubMed

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal

  20. Tibial Eminence Involvement With Tibial Plateau Fracture Predicts Slower Recovery and Worse Postoperative Range of Knee Motion.

    PubMed

    Konda, Sanjit R; Driesman, Adam; Manoli, Arthur; Davidovitch, Roy I; Egol, Kenneth A

    2017-07-01

    To examine 1-year functional and clinical outcomes in patients with tibial plateau fractures with tibial eminence involvement. Retrospective analysis of prospectively collected data. Academic Medical Center. All patients who presented with a tibial plateau fracture (Orthopaedic Trauma Association (OTA) 41-B and 41-C). Patients were divided into fractures with a tibial eminence component (+TE) and those without (-TE) cohorts. All patients underwent similar surgical approaches and fixation techniques for fractures. No tibial eminence fractures received fixation specifically. Short musculoskeletal functional assessment (SMFA), pain (Visual Analogue Scale), and knee range-of-motion (ROM) were evaluated at 3, 6, and 12 months postoperatively and compared between cohorts. Two hundred ninety-three patients were included for review. Patients with OTA 41-C fractures were more likely to have an associated TE compared with 41-B fractures (63% vs. 28%, P < 0.01). At 3 months postoperatively, the +TE cohort was noted to have worse knee ROM (75.16 ± 51 vs. 86.82 ± 53 degree, P = 0.06). At 6 months, total SMFA and knee ROM was significantly worse in the +TE cohort (29 ± 17 vs. 21 ± 18, P ≤ 0.01; 115.6 ± 20 vs. 124.1 ± 15, P = 0.01). By 12 months postoperatively, only knee ROM remained significantly worse in the +TE cohort (118.7 ± 15 vs. 126.9 ± 13, P < 0.01). Multivariate analysis revealed that tibial eminence involvement was a significant predictor of ROM at 6 and 12 months and SFMA at 6 months. Body mass index was found to be a significant predictor of ROM and age was a significant predictor of total SMFA at all time points. Knee ROM remains worse throughout the postoperative period in the +TE cohort. Functional outcome improves less rapidly in the +TE cohort but achieves similar results by 1 year. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  1. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study.

    PubMed

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-Ichi

    2017-06-18

    To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fracture and the geometry of the tibial plateau were reviewed and measured on MRI. Thirteen of 14 stress fractures were linear, and one of them stellated on MRI images. The location of fractures was classified into three types. Three fractures were located anteromedially (AM type), six posteromedially (PM type), and five posteriorly (P type) at the medial tibial plateau. In addition, tibial posterior slope at the medial tibial plateau tended to be larger when the fracture was located more posteriorly on MRI. We found that MRI showed three different localizations of medial tibial plateau stress fractures, which were associated with tibial posterior slope at the medial tibial plateau.

  2. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study

    PubMed Central

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-ichi

    2017-01-01

    AIM To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). METHODS A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fracture and the geometry of the tibial plateau were reviewed and measured on MRI. RESULTS Thirteen of 14 stress fractures were linear, and one of them stellated on MRI images. The location of fractures was classified into three types. Three fractures were located anteromedially (AM type), six posteromedially (PM type), and five posteriorly (P type) at the medial tibial plateau. In addition, tibial posterior slope at the medial tibial plateau tended to be larger when the fracture was located more posteriorly on MRI. CONCLUSION We found that MRI showed three different localizations of medial tibial plateau stress fractures, which were associated with tibial posterior slope at the medial tibial plateau. PMID:28660141

  3. Reliability of frames of reference used for tibial component rotation in total knee arthroplasty.

    PubMed

    Page, Stephen R; Deakin, Angela H; Payne, Anthony P; Picard, Frederic

    2011-01-01

    This study evaluated seven different frames of reference used for tibial component rotation in total knee arthroplasty (TKA) to determine which ones showed good reliability between bone specimens. An optoelectronic system based around a computer-assisted surgical navigation system was used to measure and locate 34 individual anatomical landmarks on 40 tibias. Each particular frame of reference was reconstructed from a group of data points taken from the surface of each bone. The transverse axis was used as the baseline to which the other axes were compared, and the differences in angular rotation between the other six reference frames and the transverse axis were calculated. There was high variability in the tibial rotational alignment associated with all frames of reference. Of the references widely used in current TKA procedures, the tibial tuberosity axis and the anterior condylar axis had lower standard deviations (6.1° and 7.3°, respectively) than the transmalleolar axis and the posterior condylar axis (9.3° for both). In conclusion, we found high variability in the frames of reference used for tibial rotation alignment. However, the anterior condylar axis and transverse axis may warrant further tests with the use of navigation. Combining different frames of reference such as the tibial tuberosity axis, anterior condylar axis and transverse axis may reduce the range of errors found in all of these measurements.

  4. [Surgical approaches to tibial plateau fractures].

    PubMed

    Krause, Matthias; Müller, Gunnar; Frosch, Karl-Heinz

    2018-06-06

    Intra-articular tibial plateau fractures can present a surgical challenge due to complex injury patterns and compromised soft tissue. The treatment goal is to spare the soft tissue and an anatomical reconstruction of the tibial articular surface. Depending on the course of the fracture, a fracture-specific access strategy is recommended to provide correct positioning of the plate osteosynthesis. While the anterolateral approach is used in the majority of lateral tibial plateau fractures, only one third of the joint surface is visible; however, posterolateral fragments require an individual approach, e. g. posterolateral or posteromedial. If necessary, osteotomy of the femoral epicondyles can improve joint access for reduction control. Injuries to the posterior columns should be anatomically reconstructed and biomechanically correctly addressed via posterior approaches. Bony posterior cruciate ligament tears can be refixed via a minimally invasive posteromedial approach.

  5. Tibial stress injuries: decisive diagnosis and treatment of 'shin splints'.

    PubMed

    Couture, Christopher J; Karlson, Kristine A

    2002-06-01

    Tibial stress injuries, commonly called 'shin splints,' often result when bone remodeling processes adapt inadequately to repetitive stress. Physicians who care for athletic patients need a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are implications for appropriate diagnosis, management, and prevention.

  6. Prediction of Tibial Rotation Pathologies Using Particle Swarm Optimization and K-Means Algorithms.

    PubMed

    Sari, Murat; Tuna, Can; Akogul, Serkan

    2018-03-28

    The aim of this article is to investigate pathological subjects from a population through different physical factors. To achieve this, particle swarm optimization (PSO) and K-means (KM) clustering algorithms have been combined (PSO-KM). Datasets provided by the literature were divided into three clusters based on age and weight parameters and each one of right tibial external rotation (RTER), right tibial internal rotation (RTIR), left tibial external rotation (LTER), and left tibial internal rotation (LTIR) values were divided into three types as Type 1, Type 2 and Type 3 (Type 2 is non-pathological (normal) and the other two types are pathological (abnormal)), respectively. The rotation values of every subject in any cluster were noted. Then the algorithm was run and the produced values were also considered. The values of the produced algorithm, the PSO-KM, have been compared with the real values. The hybrid PSO-KM algorithm has been very successful on the optimal clustering of the tibial rotation types through the physical criteria. In this investigation, Type 2 (pathological subjects) is of especially high predictability and the PSO-KM algorithm has been very successful as an operation system for clustering and optimizing the tibial motion data assessments. These research findings are expected to be very useful for health providers, such as physiotherapists, orthopedists, and so on, in which this consequence may help clinicians to appropriately designing proper treatment schedules for patients.

  7. The influence of a foot orthotic on lower extremity transverse plane kinematics in collegiate female athletes with pes planus.

    PubMed

    Christopher, R Carcia; Drouin, Joshua M; Houglum, Peggy A

    2006-01-01

    Non-contact anterior cruciate ligament (ACL) injuries in female athletes remain prevalent. Athletes with excessive foot pronation have been identified to be at greater risk for non-contact ACL injury. Excessive foot pronation has been linked to increased medial tibial rotation. Increased medial tibial rotation heightens ACL strain and has been observed at or near the time of ACL injury. Foot orthotics have been shown to decrease medial tibial rotation during walking and running tasks. The effect of a foot orthotic on activities that simulate a non-contact ACL injury mechanism (i.e. landing) however is unknown. Therefore, the objective of this study was to determine whether a foot orthotic was capable of altering transverse plane lower extremity kinematics in female athletes during landing. Twenty uninjured collegiate female athletes participating in the sports of basketball, soccer or volleyball with pes planus volunteered. Utilizing a repeated measures counterbalanced design, subjects completed two landing tasks with and without a foot orthotic using standardized footwear. The prefabricated orthotic had a rigid shell and a 6 extrinsic rear-foot varus post. Dependent measures included initial contact angle, peak angle, excursion and time to peak angle for both the tibia and femur. Statistical analysis suggested that the selected foot orthosis had little influence over lower extremity transverse plane kinematics. Several factors including: the limitation of a static measure to predict dynamic movement, inter-subject variability and the physical characteristics of the orthotic device likely account for the results. Future research should examine the influence of different types of foot orthotics not only on lower extremity kinematics but also tibiofemoral kinetics. Key PointsLower extremity transverse plane kinematics in female athletes during a landing task exhibit substantial variability.A rigid prefabricated foot orthotic does not significantly alter transverse

  8. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report.

    PubMed

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients.

  9. Magnitude of cement-device interfacial stresses with and without tibial stemming: impact of BMI.

    PubMed

    Gopalakrishnan, Ananthkrishnan; Hedley, Anthony Keith; Kester, Mark A

    2011-03-01

    Patients expect their total knee arthroplasty to relieve pain and to be long lasting. With patients becoming more active, weighing more, and living longer, this expectation becomes increasingly more difficult to fulfill. Patients who are obese and active put greater loads on their implants and may have a greater risk of failure. Although much attention has been paid to decreasing polyethylene wear, a major cause of implant failure, very little research focus has been directed to elucidate other measures to reduce failure, such as the efficacy of prophylactic stemming of the tibial tray. This study explored whether additional mechanical support for tibial base plates would help reduce bone cement stresses in heavy patients, who, like patients with a high activity level, put added stress on their implants. A tibial base plate with a 12-mm-diameter x 50-mm-long stem was compared with the same tibial base plate with a 15-mm-diameter x 20-mm-long end cap using finite element analysis. The results indicate that the tibial base plate with a prophylactic stem significantly reduced compressive and shear stresses on the cement-device interface and therefore may help to reduce the possibility of tibial loosening in these at-risk patients. Further, such studies will aid the surgeon in educating patients and in selecting the appropriate implant strategy.

  10. Tibial stress fracture after computer-navigated total knee arthroplasty.

    PubMed

    Massai, F; Conteduca, F; Vadalà, A; Iorio, R; Basiglini, L; Ferretti, A

    2010-06-01

    A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the operation. We present a case of a stress tibial fracture that occurred after a TKA performed with the use of a computer navigation system. The stress fracture, which eventually healed without further complications, occurred at one of the pinhole sites used for the placement of the tibial trackers.

  11. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report

    PubMed Central

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Introduction: Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. Case Report: A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. Conclusion: A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients. PMID:29181350

  12. Gender differences in passive knee biomechanical properties in tibial rotation.

    PubMed

    Park, Hyung-Soon; Wilson, Nicole A; Zhang, Li-Qun

    2008-07-01

    The anterior cruciate ligament (ACL) is the most commonly injured knee ligament with the highest incidence of injury in female athletes who participate in pivoting sports. Noncontact ACL injuries commonly occur with both internal and external tibial rotation. ACL impingement against the lateral wall of the intercondylar notch during tibial external rotation and abduction has been proposed as an injury mechanism, but few studies have evaluated in vivo gender-specific differences in laxity and stiffness in external and internal tibial rotations. The purpose of this study was to evaluate these differences. The knees of 10 male and 10 female healthy subjects were rotated between internal and external tibial rotation with the knee at 60 degrees of flexion. Joint laxity, stiffness, and energy loss were compared between male and female subjects. Women had higher laxity (p = 0.01), lower stiffness (p = 0.038), and higher energy loss (p = 0.008) in external tibial rotation than did men. The results suggest that women may be at greater risk of ACL injury resulting from impingement against the lateral wall of the intercondylar notch, which has been shown to be associated with external tibial rotation and abduction.

  13. Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.

    PubMed

    Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao

    2017-12-01

    The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.

  14. Differences between opening versus closing high tibial osteotomy on clinical outcomes and gait analysis.

    PubMed

    Deie, Masataka; Hoso, Takayuki; Shimada, Noboru; Iwaki, Daisuke; Nakamae, Atsuo; Adachi, Nobuo; Ochi, Mitsuo

    2014-12-01

    High tibial osteotomy (HTO) for medial knee osteoarthritis (OA) is mainly performed via two procedures: closing wedge HTO (CW) and opening wedge HTO (OW). In this study, differences between these procedures were assessed by serial clinical evaluation and gait analysis before and after surgery. Twenty-one patients underwent HTO for medial knee OA in 2011 and 2012, with 12 patients undergoing CW and nine undergoing OW. The severity of OA was classified according to the Kellgren-Lawrence classification. The Japanese Orthopedic Association score for assessment of knee OA (JOA score), the Numeric Rating Scale (NRS), and the femoral tibial angle (FTA) on X-ray were evaluated. For gait analysis, gait speed, varus moment, varus angle and lateral thrust were calculated. The JOA score and NRS were improved significantly one year postoperatively in both groups. The FTA was maintained in both groups at one year. Varus angle and varus moment were significantly improved in both groups at each postoperative follow-up, when compared preoperatively. Lateral thrust was significantly improved at three months postoperatively in both groups. However, the significant improvement in lateral thrust had disappeared in the CW group six months postoperatively, whereas it was maintained for at least one year in the OW group. This study found that clinical outcomes were well maintained after HTO. OW reduced knee varus moment and lateral thrust, whereas CW had little effect on reducing lateral thrust. Level IV. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. [Operative treatment for complex tibial plateau fractures].

    PubMed

    Song, Qi-Zhi; Li, Tao

    2012-03-01

    To explore the surgical methods and clinical evaluation of complex tibial plateau fractures resulted from high-energy injuries. From March 2006 to May 2009,48 cases with complex tibial plateau fractures were treated with open reduction and plate fixation, including 37 males and 11 females, with an average age of 37 years (ranged from 18 to 63 years). According to Schatzker classification, 16 cases were type IV, 20 cases type V and 12 cases type VI. All patients were examined by X-ray flim and CT scan. The function of knee joint were evaluated according to postoperative follow-up X-ray and Knee Merchant Rating. Forty-eight patients were followed up with a mean time of 14 months. According to Knee Merchant Rating, 24 cases got excellent results, 16 cases good, 6 cases fair and 2 cases poor. Appropriate operation time, anatomical reduction, suitable bone graft and reasonable rehabilitation exercises can maximally recovery the function of knee joint.

  16. 129. HEAD OF PLANE 12 EAST AT HIGH ST. IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    129. HEAD OF PLANE 12 EAST AT HIGH ST. IN NEWARK. FLUME AND POWER HOUSE ARE IN RIGHT HAND SIDE OF PHOTOGRAPH. THIS IS THE LAST DOUBLE TRACKED PLANE ON THE MORRIS CANAL. - Morris Canal, Phillipsburg, Warren County, NJ

  17. Stretching the indications: high tibial osteotomy used successfully to treat isolated ankle symptoms

    PubMed Central

    Elson, David W; Paweleck, James E; Shields, David W; Dawson, Matthew J; Ferrier, Gail M

    2013-01-01

    High tibial osteotomy (HTO) is successful in treating symptomatic varus arthritis of the knee. We present a case where ankle pain and instability were attributed to varus ankle malalignment. This was found to be secondary to constitutional varus of the proximal tibia but the patient's knee was asymptomatic. The decision to operate on an asymptomatic knee in the hope of improving ankle symptoms took a period of careful consideration, planning and discussion. HTO was performed without immediate complication and the patient reported an excellent outcome with marked improvement in Mazur's foot and ankle score from 18 to 85. In well selected and planned cases, HTO may be considered as an instrument of deformity correction with improvement in symptoms from joints distant to the surgical site. PMID:24022901

  18. Open-Wedge High Tibial Osteotomy: RCT 2 Years RSA Follow-Up.

    PubMed

    Lind-Hansen, Thomas Bruno; Lind, Martin Carøe; Nielsen, Poul Torben; Laursen, Mogens Berg

    2016-11-01

    We investigated the influence of three different bone grafting materials on stability and clinical outcome of the healing open-wedge high tibial osteotomy (OW-HTO) with immediate partial weight bearing. A total of 45 (3 × 15) patients were randomized to injectable calcium phosphate cement (Calcibon; Biomet-Merck Biomaterials GmbH, Darmstadt, Germany), local bone autograft, or iliac crest autograft. Stability of the bony healing was evaluated with radiostereometric analysis (RSA) up to 24 months postoperatively. Clinical outcome was evaluated with the knee injury and osteoarthritis outcome score (KOOS). RSA revealed translations and rotations close to zero regardless of bone grafting material, with no statistically significant differences between the groups. Clinically, the Calcibon group had lower quality of life KOOS subscore at 2 years follow-up. We conclude that with a stable implant and 6 weeks of partial weight bearing, local autografting is sufficient to achieve solid bone consolidation following OW-HTO. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. The soleal line: a cause of tibial pseudoperiostitis.

    PubMed

    Levine, A H; Pais, M J; Berinson, H; Amenta, P S

    1976-04-01

    An unusually prominent soleal line (a normal anatomic variant) may mimic periosteal reaction along the posterior margin of the proximal tibial shaft. This area of pseudoperiostitis is differentiated from hyperostoses arising from the anterior tibial tubercle and the interosseous membrane. It is always associated with normal, undisturbed architecture of the underlying bone.

  20. Relationship between the tibial mechanical axis and bony anatomical landmarks of the calf and foot as measured on radiographs obtained with a new laser-calibrated position.

    PubMed

    He, Peiheng; Zhu, Qi; Zhang, Zhaohui; Zou, Xuenong; Xu, Dongliang

    2013-01-01

    To investigate relationship between the tibial mechanical axis and bony landmarks of the calf and foot by developing a new laser-calibrated position for radiography of the lower limb. A total of 120 volunteers were randomly divided into two groups. All subjects were marked with skin projection of the hypothetical axis of the calf on the frontal and sagittal planes. Radiographs of weight-bearing full-length lower-limb were obtained by the laser-calibrated positioning in the experimental group, and by the use of conventional technique in the control group. To consider the rotation of the calf, radiological features of the knee and ankle were investigated. The relationship between the tibial mechanical axis and the bony landmarks of the calf and foot were also measured. Anteroposterior view depicted a tangential projection on the superior/inferior tibiofibular syndesmosis and between lateral malleolus and talus in ankle mortise in the experimental group. Bony overlap on the superior/inferior tibiofibular syndesmosis and between lateral malleolus and talus was seen in control group. On the tangential projection, it also presented a clear wheel-like contour of the medial femoral condyle, but a partial overlap between medial femoral condyle and tibial plateau. The femoral joint angle between the connecting line at the lowest point of the medial and lateral femoral condyles and the tibial mechanical axis was 83.6° ± 2.49° in the experimental group and 85.3° ± 2.18° in the control group (P < 0.001). The tibial tubercle-axis distance from the center of the medial and middle one-third of the tibial tubercle to the tibial mechanical axis was 1.5 mm in the experimental group and 3.7 mm in the control group (P < 0.05). The malleoli-axis distance from the midpoint of the bimalleolar line joining the tips of the medial and lateral malleoli to the tibial mechanical axis was 1.9 mm in the experimental group and 6.9 mm in the control group (P < 0.001). Lateral view showed no

  1. Changes in coronal alignment of the ankle joint after high tibial osteotomy.

    PubMed

    Choi, Gi Won; Yang, Jae Hyuk; Park, Jung Ho; Yun, Ho Hyun; Lee, Yong In; Chae, Jin Eon; Yoon, Jung Ro

    2017-03-01

    The purpose of this study was to investigate changes in coronal alignment of the ankle joint after HTO. Our hypothesis was that ankle joint orientation may become more parallel or less parallel to the ground after HTO, and this change may affect ankle symptoms. Eighty-six knees were retrospectively analysed after HTO for varus osteoarthritis. Preoperative and follow-up whole-leg radiographs were taken. The hip-knee-ankle (HKA) angle and medial proximal tibial angle (MPTA) were measured to evaluate coronal alignment of the knee. Tibial plafond inclination (TPI), talar inclination (TI), talar tilt (TT), and lateral distal tibial angle (LDTA) were measured to evaluate coronal alignment of the ankle. Patients were divided into two groups: those who exhibited a decrease in the absolute value of TPI and TI after HTO (group A) and those who exhibited an increase in the absolute value of TPI or TI after HTO (group B). Clinical outcomes of the knee and ankle were evaluated pre- and postoperatively. Mean TPI and TI changed from 6.9° ± 3.6° and 8.0° ± 3.8° to 2.8° ± 3.1° and 3.9° ± 3.0° in group A (P < 0.001 for both) and from -1.3° ± 3.7° and 0.6° ± 4.5° to -6.0° ± 4.2° and -4.6° ± 5.9° in group B (P = 0.018 for both). VAS for ankle pain did not change significantly after HTO (n.s.) in group A, whereas those of group B increased significantly after HTO (P = 0.014). Ankle joint orientation becomes more parallel or less parallel to the ground after HTO. Smaller preoperative HKA and LDTA result in a more valgus ankle joint orientation after HTO. Ankle symptoms were affected by coronal alignment changes of the ankle after HTO. III.

  2. "Clothesline technique" for proximal tibial shaft fracture fixation using conventional intramedullary nail: a simple, useful, and inexpensive technique to prevent fracture malalignment.

    PubMed

    Belangero, William Dias; Santos Pires, Robinson Esteves; Livani, Bruno; Rossi, Felipe Lins; de Andrade, Andre Luis Lugnani

    2018-05-01

    Treatment of proximal tibial shaft fractures is always challenging. Despite the development of modern techniques, the literature still shows high complication rates, especially regarding proximal fragment malalignment. It is well known that knee position in flexion during tibial nailing is responsible for extension and valgus deformities of the proximal fragment. Unlike in tibial shaft fractures, nails do not reduce proximal tibial fractures due to the medullary canal width. This study aims to describe a simple, useful, and inexpensive technique to prevent valgus and extension deformities when treating proximal tibial fractures using conventional nails: the so-called clothesline technique.

  3. [Influencing factors for trauma-induced tibial infection in underground coal mine].

    PubMed

    Meng, W Z; Guo, Y J; Liu, Z K; Li, Y F; Wang, G Z

    2016-07-20

    Objective: To investigate the influencing factors for trauma-induced tibial infection in underground coal mine. Methods: A retrospective analysis was performed for the clinical data of 1 090 patients with tibial fracture complicated by bone infection who were injured in underground coal mine and admitted to our hospital from January 1995 to August 2015, including the type of trauma, injured parts, severity, and treatment outcome. The association between risk factors and infection was analyzed. Results: Among the 1 090 patients, 357 had the clinical manifestations of acute and chronic bone infection, 219 had red and swollen legs with heat pain, and 138 experienced skin necrosis, rupture, and discharge of pus. The incidence rates of tibial infection from 1995 to 2001, from 2002 to 2008, and from 2009 to 2015 were 31%, 26.9%, and 20.2%, respectively. The incidence rate of bone infection in the proximal segment of the tibia was significantly higher than that in the middle and distal segments (42.1% vs 18.9%/27.1%, P <0.01) . As for patients with different types of trauma (Gustilo typing) , the patients with type III fracture had a significantly higher incidence rate of bone infection than those with type I/II infection (52.8% vs 21.8%/24.6%, P <0.01) . The incidence rates of bone infection after bone traction, internal fixation with steel plates, fixation with external fixator, and fixation with intramedullary nail were 20.7%, 43.5%, 21.4%, and 26.1%, respectively, suggesting that internal fixation with steel plates had a significantly higher incidence rate of bone infection than other fixation methods ( P <0.01) . The multivariate logistic regression analysis showed that the position of tibial fracture and type of fracture were independent risk factors for bone infection. Conclusion: There is a high incidence rate of trauma-induced tibial infection in workers in underground coal mine. The position of tibial fracture and type of fracture are independent risk factors

  4. Clinical field follow-up of high density polyethylene (HDPE)-Jaipur prosthetic technology for trans-tibial amputees.

    PubMed

    Jensen, J S; Craig, J G; Mtalo, L B; Zelaya, C M

    2004-12-01

    The purpose of this study was to examine the outcome of the application of the High Density Polyethylene (HDPE)-Jaipur prosthetic construction in fitting trans-tibial amputees in a number of projects in the developing world. Projects in Honduras, Uganda and India were visited. Three hundred and twenty (320) patients had been provided with a HDPE-Jaipur prosthesis and of these 172 were seen for a technical and clinical follow-up after a median of 35 months. More than half the amputations were due to trauma, the remainder to disease. Fabrication and fitting in the three projects was carried out by individuals who had undertaken a twice week training course provided by Bhagwan Mahaveer Viklang Sahayata Samiti limb centre in Jaipur. The individuals involved had limited background training in prosthetics. Craftsmanship and fit were assessed as being poor in 56% of cases. The technical quality of the Jaipur foot was considered acceptable as its performance was better than previously observed results. Although there was patient satisfaction of 85% and compliance of 94% the HDPE-Jaipur trans-tibial system was not considered acceptable as 49% reported walking distances less than 1km and 36% discomfort. The major inadequacy in outcome relates to the use for fabrication and fitting of individuals with inadequate education and training.

  5. Total knee arthroplasty after failed high tibial osteotomy: a systematic review of open versus closed wedge osteotomy.

    PubMed

    Han, Jae Hwi; Yang, Jae-Hyuk; Bhandare, Nikhl N; Suh, Dong Won; Lee, Jong Seong; Chang, Yong Suk; Yeom, Ji Woong; Nha, Kyung Wook

    2016-08-01

    Medial opening wedge high tibial osteotomy (HTO) has become increasingly popular as an alternative to lateral closing wedge osteotomy for the treatment of medial compartment knee osteoarthritis with varus deformity. The present systematic review was conducted to provide an objective analysis of total knee arthroplasty (TKA) outcomes following previous knee osteotomy (medial opening wedge vs. lateral closing wedge). A literature search of online databases (MEDLINE, EMBASE, Cochrane Library database) was made, in addition to manual search of major orthopaedic journals. The methodological quality of each of the studies was assessed on the Newcastle-Ottawa Scale and Effective Practice and Organization of Care. A total of ten studies were included in the review. There were eight studies with Level IV and two studies with Level III evidence. Eight studies reported clinical and radiologic scores. Comparative studies between TKA following medial opening and lateral closing wedge HTO did not demonstrate statistically significant clinical and radiologic differences. The revision rates were similar. However, more technical issues during TKA surgery after lateral closing wedge HTO were mentioned than the medial open wedge group. The quadriceps snip, tibial tubercle osteotomy, and lateral soft tissue release were more frequently needed in the lateral closing wedge HTO group. In addition, because of loss of proximal tibia bone geometry in the lateral closing wedge HTO group, concerns such as tibia stem impingement in the lateral tibial cortex was noted. The present systematic review suggests that TKA after medial opening and lateral closing wedge HTO showed similar performance. Clinical and radiologic outcome including revision rates did not statistically differ from included studies. However, there are more surgical technical concerns in TKA conversion from lateral closing wedge HTO than from the medial opening wedge HTO group. IV.

  6. Importance of tibial slope for stability of the posterior cruciate ligament deficient knee.

    PubMed

    Giffin, J Robert; Stabile, Kathryne J; Zantop, Thore; Vogrin, Tracy M; Woo, Savio L-Y; Harner, Christopher D

    2007-09-01

    Previous studies have shown that increasing tibial slope can shift the resting position of the tibia anteriorly. As a result, sagittal osteotomies that alter slope have recently been proposed for treatment of posterior cruciate ligament (PCL) injuries. Increasing tibial slope with an osteotomy shifts the resting position anteriorly in a PCL-deficient knee, thereby partially reducing the posterior tibial "sag" associated with PCL injury. This shift in resting position from the increased slope causes a decrease in posterior tibial translation compared with the PCL-deficient knee in response to posterior tibial and axial compressive loads. Controlled laboratory study. Three knee conditions were tested with a robotic universal force-moment sensor testing system: intact, PCL-deficient, and PCL-deficient with increased tibial slope. Tibial slope was increased via a 5-mm anterior opening wedge osteotomy. Three external loading conditions were applied to each knee condition at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of knee flexion: (1) 134-N anterior-posterior (A-P) tibial load, (2) 200-N axial compressive load, and (3) combined 134-N A-P and 200-N axial loads. For each loading condition, kinematics of the intact knee were recorded for the remaining 5 degrees of freedom (ie, A-P, medial-lateral, and proximal-distal translations, internal-external and varus-valgus rotations). Posterior cruciate ligament deficiency resulted in a posterior shift of the tibial resting position to 8.4 +/- 2.6 mm at 90 degrees compared with the intact knee. After osteotomy, tibial slope increased from 9.2 degrees +/- 1.0 degrees in the intact knee to 13.8 degrees +/- 0.9 degrees. This increase in slope reduced the posterior sag of the PCL-deficient knee, shifting the resting position anteriorly to 4.0 +/- 2.0 mm at 90 degrees. Under a 200-N axial compressive load with the osteotomy, an additional increase in anterior tibial translation to 2.7 +/- 1.7 mm at 30 degrees was

  7. Tibial Bowing and Pseudarthrosis in Neurofibromatosis Type 1

    DTIC Science & Technology

    2014-04-01

    Neurofibromatosis Type 1 PRINCIPAL INVESTIGATOR: Dr. David Stevenson CONTRACTING ORGANIZATION: University of Utah SALT LAKE CITY...COVERED 1 April 2013 - 31 March 2014 4. TITLE AND SUBTITLE Tibial Bowing and Pseudarthrosis in Neurofibromatosis Type 1 5a. CONTRACT NUMBER...SUPPLEMENTARY NOTES 14. ABSTRACT Anterolateral tibial bowing is a morbid skeletal manifestation observed in 5% of children with neurofibromatosis

  8. Comparison of volumetric bone mineral density in the tibial region of interest for ACL reconstruction.

    PubMed

    Klein, Scott A; Nyland, John; Caborn, David N M; Kocabey, Yavuz; Nawab, Akbar

    2005-12-01

    Adequate tibial bone mineral density (BMD) is essential to soft tissue graft fixation during anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to compare volumetric bone plug density measurements at the tibial region of interest for ACL reconstruction using a standardized immersion technique and Archimedes' principle. Cancellous bone cores were harvested from the proximal, middle, and distal metaphyseal regions of the lateral tibia and from the standard tibial tunnel location used for ACL reconstruction of 18 cadaveric specimens. Proximal tibial cores displayed 32.6% greater BMD than middle tibial cores and 31.8% greater BMD than distal tibial cores, but did not differ from the BMD of the tibial tunnel cores. Correlational analysis confirmed that the cancellous BMD in the tibial tunnel related to the cancellous BMD of the proximal and distal lateral tibial metaphysis. In conjunction with its adjacent cortical bone, the cancellous BMD of the region used for standard tibial tunnel placement provides an effective foundation for ACL graft fixation. In tibia with poor BMD, bicortical fixation that incorporates cortical bone from the distal tibial tunnel region is recommended.

  9. Cranial tibial thrust: a primary force in the canine stifle.

    PubMed

    Slocum, B; Devine, T

    1983-08-15

    A cranially directed force identified within the canine stifle joint was termed cranial tibial thrust. It was generated during weight bearing by tibial compression, of which the tarsal tendon of the biceps femoris is a major contributor, and by the slope of the tibial plateau, found to have a mean cranially directed inclination of 22.6 degrees. This force may be an important factor in cranial cruciate ligament rupture and in generation of cranial drawer sign.

  10. Tibial component coverage based on bone mineral density of the cut tibial surface during unicompartmental knee arthroplasty: clinical relevance of the prevention of tibial component subsidence.

    PubMed

    Lee, Yong Seuk; Yun, Ji Young; Lee, Beom Koo

    2014-01-01

    An optimally implanted tibial component during unicompartmental knee arthroplasty would be flush with all edges of the cut tibial surface. However, this is often not possible, partly because the tibial component may not be an ideal shape or because the ideal component size may not be available. In such situations, surgeons need to decide between component overhang and underhang and as to which sites must be covered and which sites could be undercovered. The objectives of this study were to evaluate the bone mineral density of the cut surface of the proximal tibia around the cortical rim and to compare the bone mineral density according to the inclusion of the cortex and the site-specific matched evaluation. One hundred and fifty consecutive patients (100 men and 50 women) were enrolled in this study. A quantitative computed tomography was used to determine the bone density of the cut tibial surface. Medial and lateral compartments were divided into anterior, middle, and posterior regions, and these three regions were further subdivided into two regions according to containment of cortex. The site-specific matched comparison (medial vs. lateral) of bone mineral density was performed. In medial sides, the mid-region, including the cortex, showed the highest bone mineral density in male and female patients. The posterior region showed the lowest bone mineral density in male patients, and the anterior and posterior regions showed the lowest bone mineral density in female patients. Regions including cortex showed higher bone mineral density than pure cancellous regions in medial sides. In lateral sides, posterior regions including cortex showed highest bone mineral density with statistical significance in both male and female patients. The anterior region showed the lowest bone mineral density in both male and female patients. The mid-region of the medial side and the posterior region of the lateral side are relatively safe without cortical coverage when the component

  11. Total knee arthroplasty and fractures of the tibial plateau

    PubMed Central

    Softness, Kenneth A; Murray, Ryan S; Evans, Brian G

    2017-01-01

    Tibial plateau fractures are common injuries that occur in a bimodal age distribution. While there are various treatment options for displaced tibial plateau fractures, the standard of care is open reduction and internal fixation (ORIF). In physiologically young patients with higher demand and better bone quality, ORIF is the preferred method of treating these fractures. However, future total knee arthroplasty (TKA) is a consideration in these patients as post-traumatic osteoarthritis is a common long-term complication of tibial plateau fractures. In older, lower demand patients, ORIF is potentially less favorable for a variety of reasons, namely fixation failure and the need for delayed weight bearing. In some of these patients, TKA can be considered as primary mode of treatment. This paper will review the literature surrounding TKA as both primary treatment and as a salvage measure in patients with fractures of the tibial plateau. The outcomes, complications, techniques and surgical challenges are also discussed. PMID:28251061

  12. Effect of open wedge high tibial osteotomy on the lateral compartment in sheep. Part I: Analysis of the lateral meniscus.

    PubMed

    Madry, Henning; Ziegler, Raphaela; Orth, Patrick; Goebel, Lars; Ong, Mei Fang; Kohn, Dieter; Cucchiarini, Magali; Pape, Dietrich

    2013-01-01

    To evaluate whether medial open wedge high tibial osteotomy (HTO) results in structural and biochemical changes in the lateral meniscus in adult sheep. Three experimental groups with biplanar osteotomies of the right proximal tibiae were tested: (a) closing wedge HTO resulting in 4.5° of tibial varus, (b) open wedge HTO resulting in 4.5° of tibial valgus (standard correction) and (c) open wedge HTO resulting in 9.5° of valgus (overcorrection), each of which was compared to the contralateral knees with normal limb axes. After 6 months, the lateral menisci were macroscopically and microscopically evaluated. The proteoglycan and DNA contents of the red-red and white-white zones of the anterior, middle and posterior third were determined. Semiquantitative macroscopic and microscopic grading revealed no structural differences between groups. The red-red zone of the middle third of the lateral menisci of animals that underwent overcorrection exhibited a significant 0.7-fold decrease in mean DNA contents compared with the control knee without HTO (P = 0.012). Comparative estimation of the DNA and proteoglycan contents and proteoglycan/DNA ratios of all other parts and zones of the lateral menisci did not reveal significant differences between groups. Open wedge HTO does not lead to significant macroscopic and microscopic structural changes in the lateral meniscus after 6 months in vivo. Overcorrection significantly decreases the proliferative activity of the cells in the red-red zone of the middle third in the sheep model.

  13. Estimates of Tibial Shock Magnitude in Men and Women at the Start and End of a Military Drill Training Program.

    PubMed

    Rice, Hannah M; Saunders, Samantha C; McGuire, Stephen J; O'Leary, Thomas J; Izard, Rachel M

    2018-03-26

    Foot drill is a key component of military training and is characterized by frequent heel stamping, likely resulting in high tibial shock magnitudes. Higher tibial shock during running has previously been associated with risk of lower limb stress fractures, which are prevalent among military populations. Quantification of tibial shock during drill training is, therefore, warranted. This study aimed to provide estimates of tibial shock during military drill in British Army Basic training. The study also aimed to compare values between men and women, and to identify any differences between the first and final sessions of training. Tibial accelerometers were secured on the right medial, distal shank of 10 British Army recruits (n = 5 men; n = 5 women) throughout a scheduled drill training session in week 1 and week 12 of basic military training. Peak positive accelerations, the average magnitude above given thresholds, and the rate at which each threshold was exceeded were quantified. Mean (SD) peak positive acceleration was 20.8 (2.2) g across all sessions, which is considerably higher than values typically observed during high impact physical activity. Magnitudes of tibial shock were higher in men than women, and higher in week 12 compared with week 1 of training. This study provides the first estimates of tibial shock magnitude during military drill training in the field. The high values suggest that military drill is a demanding activity and this should be considered when developing and evaluating military training programs. Further exploration is required to understand the response of the lower limb to military drill training and the etiology of these responses in the development of lower limb stress fractures.

  14. Tibial interface wear in retrieved total knee components and correlations with modular insert motion.

    PubMed

    Rao, Anand R; Engh, Gerard A; Collier, Matthew B; Lounici, Smain

    2002-10-01

    Wear occurring at the interface between the polyethylene insert and metal baseplate of a modular tibial component has become an increasingly common finding at the time of revision total knee arthroplasty. Although this so-called backside wear on retrieved polyethylene inserts has been evaluated in prior studies, wear on retrieved metal baseplates has not been described, to our knowledge. The purposes of the present study were to characterize backside wear on retrieved polyethylene inserts and on the mating surfaces of their corresponding baseplates and to investigate if there is a relationship between backside wear and relative motion of the modular elements. Twenty-nine retrieved modular tibial components of twelve fixed-bearing designs were analyzed in vitro with regard to backside wear and relative motion between the polyethylene insert and the metal baseplate. We graded the backside of each polyethylene insert and the mating surface of the metal baseplate for wear with use of a scoring system that consisted of three modes of wear and three levels of severity of wear. Relative motion between the insert and the baseplate was measured in the transverse plane with use of a mechanical testing machine. These measurements were used to compute the insert motion index, which served to quantify unrestricted motion of the insert with respect to the baseplate. The mean insert motion index for the tibial components was 416 micro m (range, 104 micro m to 760 micro m). On a wear-grading scale ranging from 0 to 54 (with 0 indicating no wear), the mean backside wear score was 30 (range, 12 to 48) for the inserts and 28 (range, 7 to 51) for the baseplates. Insert motion was positively correlated with backside polyethylene wear (p = 0.003) and baseplate wear (p < 0.001). Baseplate wear was strongly correlated with backside polyethylene wear (p < 0.001). Backside wear was correlated with the relative motion between the polyethylene insert and the metal baseplate. New locking

  15. Can the tibial slope be measured on lateral knee radiographs?

    PubMed

    Faschingbauer, M; Sgroi, M; Juchems, M; Reichel, H; Kappe, T

    2014-12-01

    The posterior tibial slope influences both the natural knee stability as well as the stability and kinematics after total knee arthroplasty (TKA). Exact definition of the posterior tibial slope (PTS) requires lateral radiographs of the lower limb. Only lateral knee radiographs are routinely obtained after TKA, however. The purpose of the present study therefore was to analyse the relationship between PTS measurement results on short and expanded lateral knee radiographs. The PTS was measured on 100 consecutive lateral radiographs of the lower limb using the mechanical and three diaphyseal axes with various distances below the tibial plateau. Significant differences between PTS results were found for all three diaphyseal axes, with the smallest differences and the strongest correlation for a diaphyseal axis at 16 and 20 cm below the tibial plateau. Using short distances below the tibial plateau (6 and 10 cm) resulted in an overestimation of the PTS of 3°, on average. The PTS measurements in long lateral knee radiographs are more accurate compared to short radiographs. On short lateral knee radiographs, only a estimation of the PTS can be carried out. Diagnostic study, Level II.

  16. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  17. Posterior tibial slope as a risk factor for anterior cruciate ligament rupture in soccer players.

    PubMed

    Senişik, Seçkin; Ozgürbüz, Cengizhan; Ergün, Metin; Yüksel, Oğuz; Taskiran, Emin; Işlegen, Cetin; Ertat, Ahmet

    2011-01-01

    Anterior cruciate ligament (ACL) is the primary stabilizer of the knee. An impairment of any of the dynamic or static stability providing factors can lead to overload on the other factors and ultimately to deterioration of knee stability. This can result in anterior tibial translation and rupture of the ACL. The purpose of this study was to examine the influence of tibial slope on ACL injury risk on soccer players. A total of 64 elite soccer players and 45 sedentary controls were included in this longitudinal and controlled study. The angle between the tibial mid-diaphysis line and the line between the anterior and posterior edges of the medial tibial plateau was measured as the tibial slope via lateral radiographs. Individual player exposure, and injuries sustained by the participants were prospectively recorded. Eleven ACL injuries were documented during the study period. Tibial slope was not different between soccer players and sedentary controls. Tibial slope in the dominant and non-dominant legs was greater for the injured players compared to the uninjured players. The difference reached a significant level only for the dominant legs (p < 0.001). While the tibial slopes of the dominant and non-dominant legs were not different on uninjured players (p > 0.05), a higher tibial slope was observed in dominant legs of injured players (p < 0.05). Higher tibial slope on injured soccer players compared to the uninjured ones supports the idea that the tibial slope degree might be an important risk factor for ACL injury. Key pointsDominant legs' tibial slopes of the injured players were significantly higher compared to the uninjured players (p < 0.001).Higher tibial slope was determined in dominant legs compared to the non-dominant side, for the injured players (p = 0.042). Different tibial slope measures in dominant and non-dominant legs might be the result of different loading and/or adaptation patterns in soccer.

  18. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  19. Computer assisted alignment of opening wedge high tibial osteotomy provides limited improvement of radiographic outcomes compared to flouroscopic alignment.

    PubMed

    Stanley, Jeremy C; Robinson, Kerian G; Devitt, Brian M; Richmond, Anneka K; Webster, Kate E; Whitehead, Timothy S; Feller, Julian A

    2016-03-01

    There are numerous methods available to assist surgeons in the accurate correction of varus alignment during medial opening wedge high tibial osteotomy (MOWHTO). Preoperative planning performed with radiographs or more recently intraoperative computer navigation software has been used. The aim of the study was to compare the accuracy of computer navigated versus non-navigated techniques to correct varus alignment of the knee. The preoperative and postoperative radiographs of 117 knees that underwent MOWHTO were investigated to assess radiographic limb alignment 12-months postoperatively. The desired correction was defined as a weight bearing line (Mikulicz point {MP}) 58% of the width of the tibial plateau from the medial tibial margin. Sixty-five knees were corrected using a conventional technique and 52 knees were corrected using computer navigation. The mean MP percentage was 59% in the navigated group, compared with 56% in the fluoroscopic group (p=0.183). 51.9% of the navigation knees were corrected to within five percent of the desired correction, in contrast to 38.5% of the fluoroscopically corrected knees (p=0.15). 71.2% of the navigated knees were corrected to within 10% of the desired correction, compared with 63.1% of the fluoroscopically corrected knees (p=0.36). Large preoperative deformities were more accurately corrected with navigation assistance (57% vs 49%, p=0.049). No statistically significant difference was found in the radiographic correction of varus alignment twelve months postoperatively between navigated and fluoroscopic techniques of MOWHTO. However, a subgroup analysis demonstrated that larger preoperative varus deformities may be more accurately corrected using computer navigation. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  1. All-Polyethylene Tibial Components: An Analysis of Long-Term Outcomes and Infection.

    PubMed

    Houdek, Matthew T; Wagner, Eric R; Wyles, Cody C; Watts, Chad D; Cass, Joseph R; Trousdale, Robert T

    2016-07-01

    There is debate regarding tibial component modularity and composition in total knee arthroplasty (TKA). Biomechanical studies have suggested improved stress distribution in metal-backed tibias; however, these results have not translated clinically. The purpose of this study was to analyze the outcomes of all-polyethylene components and to compare the results to those with metal-backed components. We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970-2013). There were 28,224 (88%) metal-backed and 3715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to gender, age and body mass index (BMI). Mean follow-up was 7 years. The mean survival for all primary TKAs at the 5-, 10-, 20- and 30-year time points was 95%, 89%, 73%, and 57%, respectively. All-polyethylene tibial components were found to have a significantly improved (P < .0001) survivorship when compared with their metal-backed counterparts. All-polyethylene tibial components were also found to have a significantly lower rate of infection, instability, tibial component loosening, and periprosthetic fracture. The all-polyethylene group had improved survival rates in all age groups, except in patients 85 years old or greater, where there was no significant difference. All-polyethylene tibial components had improved survival for all BMI groups except in the morbidly obese (BMI ≥ 40) where there was no significant difference. All-polyethylene tibial components had significantly improved implant survival, reduced rates of postoperative infection, fracture, and tibial component loosening. All polyethylene should be considered for most of the patients, regardless of age and BMI. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  3. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    NASA Astrophysics Data System (ADS)

    Teeter, Matthew G.; Seslija, Petar; Milner, Jaques S.; Nikolov, Hristo N.; Yuan, Xunhua; Naudie, Douglas D. R.; Holdsworth, David W.

    2013-05-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements.

  4. Total knee replacement-cementless tibial fixation with screws: 10-year results.

    PubMed

    Ersan, Önder; Öztürk, Alper; Çatma, Mehmet Faruk; Ünlü, Serhan; Akdoğan, Mutlu; Ateş, Yalım

    2017-12-01

    The aim of this study was to evaluate the long term clinical and radiological results of cementless total knee replacement. A total of 51 knees of 49 patients (33 female and 16 male; mean age: 61.6 years (range, 29-66 years)) who underwent TKR surgery with a posterior stabilized hydroxyapatite coated knee implant were included in this study. All of the tibial components were fixed with screws. The HSS scores were examined preoperatively and at the final follow-up. Radiological assessment was performed with Knee Society evaluating and scoring system. Kaplan-Meier survival analysis was performed to rule out the survival of the tibial component. The mean HSS scores were 45.8 (range 38-60) and 88.1 (range 61-93), preoperatively and at the final follow-up respectively. Complete radiological assessment was performed for 48 knees. Lucent lines at the tibial component were observed in 4 patients; one of these patients underwent a revision surgery due to the loosening of the tibial component. The 10-year survival rate of a tibial component was 98%. Cementless total knee replacement has satisfactory long term clinical results. Primary fixation of the tibial component with screws provides adequate stability even in elderly patients with good bone quality. Level IV, Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  5. Modified arthroscopic suture fixation of a displaced tibial eminence fracture.

    PubMed

    Lehman, Ronald A; Murphy, Kevin P; Machen, M Shaun; Kuklo, Timothy R

    2003-02-01

    This study describes a new arthroscopic method using a whip-stitch technique for treating a displaced type III tibial eminence fracture. A 12-year-old girl who sustained a displaced type III tibial eminence fracture was treated with arthroscopic fixation using the Arthrosew disposable suture device (Surgical Dynamics, Norwalk, CT) to place a whip stitch into the anterior cruciate ligament (ACL). The Arthrex ACL guide (Arthrex, Naples, FL) was used to reduce the avulsed tibial spine fragment. Sutures were then passed through the tibial tunnel and secured over a bony bridge with the knee in 20 degrees of flexion. At 9 months, the patient has a full range of motion with normal Lachman and anterior drawer testing, and she has returned to competitive basketball. Radiographs show complete fracture healing. KT-1000 and isokinetic testing at 9-month follow-up show only minimal side-to-side differences. The Arthrosew device provides a significant advantage in the treatment of type III and IV fractures of the tibial eminence by obtaining arthroscopic fixation within the substance of the ACL, thus obviating arthrotomy and hardware placement. This technique also restores the proper length and tension to the ACL, and provides a simplified, reproducible method of treatment for this injury.

  6. A plane of high-velocity galaxies across the Local Group

    NASA Astrophysics Data System (ADS)

    Banik, Indranil; Zhao, Hongsheng

    2018-01-01

    We recently showed that several Local Group (LG) galaxies have much higher radial velocities (RVs) than predicted by a 3D dynamical model of the standard cosmological paradigm. Here, we show that six of these seven galaxies define a thin plane with root mean square thickness of only 101 kpc despite a widest extent of nearly 3 Mpc, much larger than the conventional virial radius of the Milky Way (MW) or M31. This plane passes within ∼70 kpc of the MW-M31 barycentre and is oriented so the MW-M31 line is inclined by 16° to it. We develop a toy model to constrain the scenario whereby a past MW-M31 flyby in Modified Newtonian Dynamics (MOND) forms tidal dwarf galaxies that settle into the recently discovered planes of satellites around the MW and M31. The scenario is viable only for a particular MW-M31 orbital plane. This roughly coincides with the plane of LG dwarfs with anomalously high RVs. Using a restricted N-body simulation of the LG in MOND, we show how the once fast-moving MW and M31 gravitationally slingshot test particles outwards at high speeds. The most distant such particles preferentially lie within the MW-M31 orbital plane, probably because the particles ending up with the highest RVs are those flung out almost parallel to the motion of the perturber. This suggests a dynamical reason for our finding of a similar trend in the real LG, something not easily explained as a chance alignment of galaxies with an isotropic or mildly flattened distribution (probability = 0.0015).

  7. Effect of tibial plateau leveling on stability of the canine cranial cruciate-deficient stifle joint: an in vitro study.

    PubMed

    Reif, Ullrich; Hulse, Donald A; Hauptman, Joe G

    2002-01-01

    To evaluate the effect of tibial plateau leveling on joint motion in canine stifle joints in which the cranial cruciate ligament (CCL) had been severed. In vitro cadaver study. Six canine cadaver hind legs. Radiographs of the stifle joints were made to evaluate the tibial plateau angle with respect to the long axis of the tibia. The specimens were mounted in a custom-made testing device to measure cranio-caudal translation of the tibia with respect to the femur. An axial load was applied to the tibia, and its position was recorded in the normal stifle, after transection of the CCL, and after tibial plateau leveling. Further, the amount of caudal tibial thrust was measured in the tibial plateau leveled specimen while series of eight linearly increasing axial tibial loads were applied. Transection of the CCL resulted in cranial tibial translation when axial tibial load was applied. After tibial plateau leveling, axial loading resulted in caudal translation of the tibia. Increasing axial tibial load caused a linear increase in caudal tibial thrust in all tibial plateau-leveled specimens. After tibial plateau leveling, axial tibial load generates caudal tibial thrust, which increases if additional axial load is applied. Tibial plateau leveling osteotomy may prevent cranial translation during weight bearing in dogs with CCL rupture by converting axial load into caudal tibial thrust. The amount of caudal tibial thrust seems to be proportional to the amount of weight bearing. Copyright 2002 by The American College of Veterinary Surgeons

  8. Predictors of failure and success of tibial interventions for critical limb ischemia.

    PubMed

    Fernandez, Nathan; McEnaney, Ryan; Marone, Luke K; Rhee, Robert Y; Leers, Steven; Makaroun, Michel; Chaer, Rabih A

    2010-10-01

    . In patients with tissue loss, 41% achieved complete closure (mean time to healing, 10.7 ± 7.4 months), and 39% exhibited partial wound healing (mean follow up, 4.4 ± 4.8 months) at last follow up. Diabetes, smoking, statin therapy, and revascularization of > 1 tibial vessel had no impact on limb salvage or wound healing. Re-intervention rate was 50% at 1 year. TAEI is an effective treatment for CLI with acceptable limb salvage and wound healing rates, but requires a high rate of reintervention. Patients with renal failure, pedal disease, or isolated peroneal runoff have poor outcomes with TAEI and should be considered for surgical bypass. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  9. Measurement of bone adjacent to tibial shaft fracture.

    PubMed

    Findlay, S C; Eastell, R; Ingle, B M

    2002-12-01

    Delayed union and non-union are common complications after fracture of the tibial shaft. Response of the surrounding bone as a fracture heals could be monitored using techniques currently used in the study of osteoporosis. The aims of our study were to: (1) evaluate the decrement in bone measurements made close to the fracture using dual-energy X-ray absorptiometry (DXA), quantitative ultrasound (QUS) and peripheral quantitative computed tomography (pQCT); (2) compare values for fractured versus non-fractured leg to determine the duration of decrement in bone measurements; and (3) calculate short-term precision in DXA, QUS and pQCT in order to calculate the ratio of decrement to precision (response ratio, RR) to determine the optimal test for monitoring changes after tibial fracture. The biggest decrement in bone measurements at the ipsilateral limb of 28 patients with tibial shaft fracture was observed at the pQCT tibial trabecular sites (distal = 19%, p<0.0001; proximal 5% = 21%, p<0.001; proximal 10% = 28%, p<0.001) and the ultradistal tibia/fibula measured by DXA (19%, p<0.0001). When comparing Z-scores, the magnitude of decrements at the ipsilateral limb was bigger for variables measured directly at the tibia, both proximal and distal to the fracture. The magnitude of the decrement in ultradistal tibia/fibula BMD decreased as the time since fracture increased ( r = 0.55). When response ratios are considered, pQCT measurements at the distal tibia (RR 6-8) and proximal 5% and 10% trabecular sites (RR 5 and 9 respectively) were found to be the most sensitive to change. Therefore, pQCT of the trabecular regions of either the proximal or distal tibia should prove the most sensitive measurement for monitoring changes in bone adjacent to a tibial shaft fracture.

  10. Ground reaction forces and bone parameters in females with tibial stress fracture.

    PubMed

    Bennell, Kim; Crossley, Kay; Jayarajan, Jyotsna; Walton, Elizabeth; Warden, Stuart; Kiss, Z Stephen; Wrigley, Tim

    2004-03-01

    Tibial stress fracture is a common overuse running injury that results from the interplay of repetitive mechanical loading and bone strength. This research project aimed to determine whether female runners with a history of tibial stress fracture (TSF) differ in ground reaction force (GRF) parameters during running, regional bone density, and tibial bone geometry from those who have never sustained a stress fracture (NSF). Thirty-six female running athletes (13 TSF; 23 NSF) ranging in age from 18 to 44 yr were recruited for this cross-sectional study. The groups were well matched for demographic, training, and menstrual parameters. A force platform measured selected GRF parameters (peak and time to peak for vertical impact and active forces, and horizontal braking and propulsive forces) during overground running at 4.0 m.s.(-1). Lumbar spine, proximal femur, and distal tibial bone mineral density were assessed by dual energy x-ray absorptiometry. Tibial bone geometry (cross-sectional dimensions and areas, and second moments of area) was calculated from a computerized tomography scan at the junction of the middle and distal thirds. There were no significant differences between the groups for any of the GRF, bone density, or tibial bone geometric parameters (P > 0.05). Both TSF and NSF subjects had bone density levels that were average or above average compared with a young adult reference range. Factor analysis followed by discriminant function analysis did not find any combinations of variables that differentiated between TSF and NSF groups. These findings do not support a role for GRF, bone density, or tibial bone geometry in the development of tibial stress fractures, suggesting that other risk factors were more important in this cohort of female runners.

  11. Medial tibial stress syndrome: a critical review.

    PubMed

    Moen, Maarten H; Tol, Johannes L; Weir, Adam; Steunebrink, Miriam; De Winter, Theodorus C

    2009-01-01

    Medial tibial stress syndrome (MTSS) is one of the most common leg injuries in athletes and soldiers. The incidence of MTSS is reported as being between 4% and 35% in military personnel and athletes. The name given to this condition refers to pain on the posteromedial tibial border during exercise, with pain on palpation of the tibia over a length of at least 5 cm. Histological studies fail to provide evidence that MTSS is caused by periostitis as a result of traction. It is caused by bony resorption that outpaces bone formation of the tibial cortex. Evidence for this overloaded adaptation of the cortex is found in several studies describing MTSS findings on bone scan, magnetic resonance imaging (MRI), high-resolution computed tomography (CT) scan and dual energy x-ray absorptiometry. The diagnosis is made based on physical examination, although only one study has been conducted on this subject. Additional imaging such as bone, CT and MRI scans has been well studied but is of limited value. The prevalence of abnormal findings in asymptomatic subjects means that results should be interpreted with caution. Excessive pronation of the foot while standing and female sex were found to be intrinsic risk factors in multiple prospective studies. Other intrinsic risk factors found in single prospective studies are higher body mass index, greater internal and external ranges of hip motion, and calf girth. Previous history of MTSS was shown to be an extrinsic risk factor. The treatment of MTSS has been examined in three randomized controlled studies. In these studies rest is equal to any intervention. The use of neoprene or semi-rigid orthotics may help prevent MTSS, as evidenced by two large prospective studies.

  12. Comparison of long-term results between osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis.

    PubMed

    Charoenrook, Victor; Michael, Ralph; de la Paz, Maria Fideliz; Temprano, José; Barraquer, Rafael I

    2018-04-01

    To compare the anatomical and the functional results between osteo-odonto-keratoprosthesis (OOKP) and keratoprosthesis using tibial bone autograft (Tibial bone KPro). We reviewed the charts of 258 patients; 145 had OOKP whereas 113 had Tibial bone KPro implanted. Functional success was defined as best corrected visual acuity ≥0.05 on decimal scale and anatomical success as retention of the keratoprosthesis lamina. Kaplan-Meier survival curves were calculated for anatomical and functional survival as well as to estimate the probability of post-op complications. The anatomical survival for both KPro groups was not significantly different and was estimated as 67% for OOKP and 54% for Tibial bone KPro at 10 years after surgery. There was also no difference found after subdividing for primary diagnosis groups such as chemical injury, thermal burn, trachoma and all autoimmune cases combined. Estimated functional survival at 10 years post-surgery was 49% for OOKP and 25% for Tibial bone KPro, which was significantly different. The probability of patients with Tibial bone KPro developing one or more post-operative complications at 10 years after surgery (65%) was significantly higher than those with OOKP (40%). Mucous membrane necrosis and retroprosthetic membrane formation were more common in Tibial bone KPro than OOKP. Both types of autologous biological KPro, OOKP and Tibial bone KPro, had statistically similar rate of keratoprosthesis extrusion. Although functional success rate was significantly higher in OOKP, it may have been influenced by a better visual potential in the patients in this group. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Tibial Acceleration and Spatiotemporal Mechanics in Distance Runners During Reduced-Body-Weight Conditions.

    PubMed

    Moran, Matthew F; Rickert, Brendan J; Greer, Beau K

    2017-05-01

    Treadmills that unload runners via a differential air-pressure (DAP) bladder (eg, AlterG Anti-Gravity Treadmill) are commonly used to reduce effective body weight (BW) in a clinical setting. However, the relationship between the level of unloading and tibial stress is currently unknown. To determine the relationship between tibial impact acceleration and level of BW unloading during running. Cross-sectional. University motion-analysis laboratory. 15 distance runners (9 male, 6 female; 20.4 ± 2.4 y, 60.1 ± 12.6 kg). Peak tibial acceleration and peak-to-peak tibial acceleration were measured via a uniaxial accelerometer attached to the tibia during a 37-min continuous treadmill run that simulated reduced-BW conditions via a DAP bladder. The trial began with a 10-min run at 100% BW followed by nine 3-min stages where BW was systematically reduced from 95% to 60% in 5% increments. There was no significant relationship between level of BW and either peak tibial acceleration or peak-to-peak tibial acceleration (P > .05). Both heart rate and step rate were significantly reduced with each 5% reduction in BW level (P < .01). Although ground-reaction forces are reduced when running in reduced-BW conditions on a DAP treadmill, tibial shock magnitudes are unchanged as an alteration in spatiotemporal running mechanics (eg, reduced step rate) and may nullify the unloading effect.

  14. The Effect of Tibial Plateau Levelling Osteotomy on Stifle Extensor Mechanism Load: A Canine Ex Vivo Study.

    PubMed

    Drew, Jarrod O; Glyde, Mark R; Hosgood, Giselle L; Hayes, Alex J

    2018-02-01

     To evaluate the effect of tibial plateau levelling osteotomy on stifle extensor mechanism load in an ex vivo cruciate-intact canine cadaveric model.   Ex vivo mechanical testing study.  Cadaveric canine pelvic limbs ( n  = 6).  A 21-mm tibial radial osteotomy was performed on pelvic limbs ( n  = 6) prior to being mounted into a load-bearing limb press. The proximal tibial segment was incrementally rotated until the anatomical tibial plateau angle had been rotated to at least 1°. The proportional change in stifle extensor mechanism load between the anatomical tibial plateau angle and the neutralized (∼6.5 degrees) and over-rotated (∼1°) tibial plateau angle was analysed using a one-sample t -test against a null hypothesis of no change. A p -value ≤0.05 was considered significant.  There was no significant change in the stifle extensor mechanism load from the anatomical tibial plateau angle (308 N [261-355 N]) to the neutralized tibial plateau angle (313 N [254-372 N]; p =.81), or from the anatomical tibial plateau angle to the over-rotated tibial plateau angle (303 N [254-352 N; p  = 0.67).  Tibial plateau levelling osteotomy does not significantly alter stifle extensor mechanism load at either a neutralized or over-rotated tibial plateau angle in our cruciate-intact model. Schattauer GmbH Stuttgart.

  15. Reliability of tunnel angle in ACL reconstruction: two-dimensional versus three-dimensional guide technique.

    PubMed

    Leiter, Jeff R S; de Korompay, Nevin; Macdonald, Lindsey; McRae, Sheila; Froese, Warren; Macdonald, Peter B

    2011-08-01

    To compare the reliability of tibial tunnel position and angle produced with a standard ACL guide (two-dimensional guide) or Howell 65° Guide (three-dimensional guide) in the coronal and sagittal planes. In the sagittal plane, the dependent variables were the angle of the tibial tunnel relative to the tibial plateau and the position of the tibial tunnel with respect to the most posterior aspect of the tibia. In the coronal plane, the dependent variables were the angle of the tunnel with respect to the medial joint line of the tibia and the medial and lateral placement of the tibial tunnel relative to the most medial aspect of the tibia. The position and angle of the tibial tunnel in the coronal and sagittal planes were determined from anteroposterior and lateral radiographs, respectively, taken 2-6 months postoperatively. The two-dimensional and three-dimensional guide groups included 28 and 24 sets of radiographs, respectively. Tibial tunnel position was identified, and tunnel angle measurements were completed. Multiple investigators measured the position and angle of the tunnel 3 times, at least 7 days apart. The angle of the tibial tunnel in the coronal plane using a two-dimensional guide (61.3 ± 4.8°) was more horizontal (P < 0.05) than tunnels drilled with a three-dimensional guide (64.7 ± 6.2°). The position of the tibial tunnel in the sagittal plane was more anterior (P < 0.05) in the two-dimensional (41.6 ± 2.5%) guide group compared to the three-dimensional guide group (43.3 ± 2.9%). The Howell Tibial Guide allows for reliable placement of the tibial tunnel in the coronal plane at an angle of 65°. Tibial tunnels were within the anatomical footprint of the ACL with either technique. Future studies should investigate the effects of tibial tunnel angle on knee function and patient quality of life. Case-control retrospective comparative study, Level III.

  16. Tibial component alignment and risk of loosening in unicompartmental knee arthroplasty: a radiographic and radiostereometric study.

    PubMed

    Barbadoro, P; Ensini, A; Leardini, A; d'Amato, M; Feliciangeli, A; Timoncini, A; Amadei, F; Belvedere, C; Giannini, S

    2014-12-01

    Unicompartmental knee arthroplasty (UKA) has shown a higher rate of revision compared with total knee arthroplasty. The success of UKA depends on prosthesis component alignment, fixation and soft tissue integrity. The tibial cut is the crucial surgical step. The hypothesis of the present study is that tibial component malalignment is correlated with its risk of loosening in UKA. This study was performed in twenty-three patients undergoing primary cemented unicompartmental knee arthroplasties. Translations and rotations of the tibial component and the maximum total point motion (MTPM) were measured using radiostereometric analysis at 3, 6, 12 and 24 months. Standard radiological evaluations were also performed immediately before and after surgery. Varus/valgus and posterior slope of the tibial component and tibial-femoral axes were correlated with radiostereometric micro-motion. A survival analysis was also performed at an average of 5.9 years by contacting patients by phone. Varus alignment of the tibial component was significantly correlated with MTPM, anterior tibial sinking, varus rotation and anterior and medial translations from radiostereometry. The posterior slope of the tibial component was correlated with external rotation. The survival rate at an average of 5.9 years was 89%. The two patients who underwent revision presented a tibial component varus angle of 10° for both. There is correlation between varus orientation of the tibial component and MTPM from radiostereometry in unicompartmental knee arthroplasties. Particularly, a misalignment in varus larger than 5° could lead to risk of loosening the tibial component. Prognostic studies-retrospective study, Level II.

  17. Influence of the posterior tibial slope on the flexion gap in total knee arthroplasty.

    PubMed

    Okazaki, Ken; Tashiro, Yasutaka; Mizu-uchi, Hideki; Hamai, Satoshi; Doi, Toshio; Iwamoto, Yukihide

    2014-08-01

    Adjusting the joint gap length to be equal in both extension and flexion is an important issue in total knee arthroplasty (TKA). It is generally acknowledged that posterior tibial slope affects the flexion gap; however, the extent to which changes in the tibial slope angle directly affect the flexion gap remains unclear. This study aimed to clarify the influence of tibial slope changes on the flexion gap in cruciate-retaining (CR) or posterior-stabilizing (PS) TKA. The flexion gap was measured using a tensor device with the femoral trial component in 20 cases each of CR- and PS-TKA. A wedge plate with a 5° inclination was placed on the tibial cut surface by switching its front-back direction to increase or decrease the tibial slope by 5°. The flexion gap after changing the tibial slope was compared to that of the neutral slope measured with a flat plate that had the same thickness as that of the wedge plate center. When the tibial slope decreased or increased by 5°, the flexion gap decreased or increased by 1.9 ± 0.6mm or 1.8 ± 0.4mm, respectively, with CR-TKA and 1.2 ± 0.4mm or 1.1 ± 0.3mm, respectively, with PS-TKA. The influence of changing the tibial slope by 5° on the flexion gap was approximately 2mm with CR-TKA and 1mm with PS-TKA. This information is useful when considering the effect of manipulating the tibial slope on the flexion gap when performing CR- or PS-TKA. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Do running speed and shoe cushioning influence impact loading and tibial shock in basketball players?

    PubMed Central

    Liebenberg, Jacobus; Woo, Jeonghyun; Park, Sang-Kyoon; Yoon, Suk-Hoon; Cheung, Roy Tsz-Hei; Ryu, Jiseon

    2018-01-01

    Background Tibial stress fracture (TSF) is a common injury in basketball players. This condition has been associated with high tibial shock and impact loading, which can be affected by running speed, footwear condition, and footstrike pattern. However, these relationships were established in runners but not in basketball players, with very little research done on impact loading and speed. Hence, this study compared tibial shock, impact loading, and foot strike pattern in basketball players running at different speeds with different shoe cushioning properties/performances. Methods Eighteen male collegiate basketball players performed straight running trials with different shoe cushioning (regular-, better-, and best-cushioning) and running speed conditions (3.0 m/s vs. 6.0 m/s) on a flat instrumented runway. Tri-axial accelerometer, force plate and motion capture system were used to determine tibial accelerations, vertical ground reaction forces and footstrike patterns in each condition, respectively. Comfort perception was indicated on a 150 mm Visual Analogue Scale. A 2 (speed) × 3 (footwear) repeated measures ANOVA was used to examine the main effects of shoe cushioning and running speeds. Results Greater tibial shock (P < 0.001; η2 = 0.80) and impact loading (P < 0.001; η2 = 0.73–0.87) were experienced at faster running speeds. Interestingly, shoes with regular-cushioning or best-cushioning resulted in greater tibial shock (P = 0.03; η2 = 0.39) and impact loading (P = 0.03; η2 = 0.38–0.68) than shoes with better-cushioning. Basketball players continued using a rearfoot strike during running, regardless of running speed and footwear cushioning conditions (P > 0.14; η2 = 0.13). Discussion There may be an optimal band of shoe cushioning for better protection against TSF. These findings may provide insights to formulate rehabilitation protocols for basketball players who are recovering from TSF. PMID:29770274

  19. Pseudoaneurysm of the Anterior Tibial Artery following Ankle Arthroscopy in a Soccer Player.

    PubMed

    Tonogai, Ichiro; Matsuura, Tetsuya; Iwame, Toshiyuki; Wada, Keizo; Takasago, Tomoya; Goto, Tomohiro; Hamada, Daisuke; Kawatani, Yohei; Fujimoto, Eiki; Kitagawa, Tetsuya; Takao, Shyoichiro; Iwamoto, Seiji; Yamanaka, Moriaki; Harada, Masafumi; Sairyo, Koichi

    2017-01-01

    Ankle arthroscopy carries a lower risk of vascular complications when standard anterolateral and anteromedial portals are used. However, the thickness of the fat pad at the anterior ankle affords little protection for the thin-walled anterior tibial artery, rendering it susceptible to indirect damage during procedures performed on the anterior ankle joint. To our knowledge, only 11 cases of pseudoaneurysm involving the anterior tibial artery after ankle arthroscopy have been described in the literature. Here we reported a rare case of a 19-year-old soccer player who presented with pseudoaneurysm of the anterior tibial artery following ankle arthroscopy using an ankle distraction method and underwent anastomosis for the anterior tibial artery injury. Excessive distraction of the ankle puts the neurovascular structures at greater risk for iatrogenic injury of the anterior tibial artery during ankle arthroscopy. Surgeons should look carefully for postoperative ankle swelling and pain after ankle arthroscopy.

  20. Pseudoaneurysm of the Anterior Tibial Artery following Ankle Arthroscopy in a Soccer Player

    PubMed Central

    Iwame, Toshiyuki; Hamada, Daisuke; Fujimoto, Eiki; Kitagawa, Tetsuya; Takao, Shyoichiro; Iwamoto, Seiji; Yamanaka, Moriaki; Harada, Masafumi

    2017-01-01

    Ankle arthroscopy carries a lower risk of vascular complications when standard anterolateral and anteromedial portals are used. However, the thickness of the fat pad at the anterior ankle affords little protection for the thin-walled anterior tibial artery, rendering it susceptible to indirect damage during procedures performed on the anterior ankle joint. To our knowledge, only 11 cases of pseudoaneurysm involving the anterior tibial artery after ankle arthroscopy have been described in the literature. Here we reported a rare case of a 19-year-old soccer player who presented with pseudoaneurysm of the anterior tibial artery following ankle arthroscopy using an ankle distraction method and underwent anastomosis for the anterior tibial artery injury. Excessive distraction of the ankle puts the neurovascular structures at greater risk for iatrogenic injury of the anterior tibial artery during ankle arthroscopy. Surgeons should look carefully for postoperative ankle swelling and pain after ankle arthroscopy. PMID:28607785

  1. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope.

    PubMed

    Shen, Yi; Li, Xiaomiao; Fu, Xiaodong; Wang, Weili

    2015-11-01

    Posterior tibial slope that is created during proximal tibial resection in total knee arthroplasty has emerged as an important factor in the mechanics of the knee joint and the surgical outcome. But the ideal degree of posterior tibial slope for recovery of the knee joint function and preventions of complications remains controversial and should vary in different racial groups. The objective of this paper is to investigate the effects of posterior tibial slope on contact stresses in the tibial polyethylene component of total knee prostheses. Three-dimensional finite element analysis was used to calculate contact stresses in tibial polyethylene component of total knee prostheses subjected to a compressive load. The 3D finite element model of total knee prosthesis was constructed from the images produced by 3D scanning technology. Stresses in tibial polyethylene component were calculated with four different posterior tibial slopes (0°, 3°, 6° and 9°). The 3D finite element model of total knee prosthesis we presented was well validated. We found that the stress distribution in the polythene as evaluated by the distributions of the von Mises stress, the maximum principle stress, the minimum principle stress and the Cpress were more uniform with 3° and 6° posterior tibial slopes than with 0° and 9° posterior tibial slopes. Moreover, the peaks of the above stresses and trends of changes with increasing degree of knee flexion were more ideal with 3° and 6° posterior slopes. The results suggested that the tibial component inclination might be favourable to 7°-10° so far as the stress distribution is concerned. The range of the tibial component inclination also can decrease the wear of polyethylene. Chinese posterior tibial slope is bigger than in the West, and the current domestic use of prostheses is imported from the West, so their demands to tilt back bone cutting can lead to shorten the service life of prostheses; this experiment result is of important

  2. The Tibial Slope in Patients With Achondroplasia: Its Characterization and Possible Role in Genu Recurvatum Development.

    PubMed

    Brooks, Jaysson T; Bernholt, David L; Tran, Kevin V; Ain, Michael C

    2016-06-01

    Genu recurvatum, a posterior resting position of the knee, is a common lower extremity deformity in patients with achondroplasia and has been thought to be secondary to ligamentous laxity. To the best of our knowledge, the role of the tibial slope has not been investigated, and no studies describe the tibial slope in patients with achondroplasia. Our goals were to characterize the tibial slope in children and adults with achondroplasia, explore its possible role in the development of genu recurvatum, and compare the tibial slope in patients with achondroplasia to that in the general population. We reviewed 252 lateral knee radiographs of 130 patients with achondroplasia seen at our clinic from November 2007 through September 2013. Patients were excluded if they had previous lower extremity surgery or radiographs with extreme rotation. We analyzed patient demographics and, on all radiographs, the tibial slope. We then compared the mean tibial slope to norms in the literature. Tibial slopes >90 degrees had an anterior tibial slope and received a positive prefix. Statistical analysis included intraclass and interclass reliability, Pearson correlation coefficient, and the Student t tests (significance, P<0.05). The overall mean tibial slope for the 252 knees was +1.32±7 degrees, which was significantly more anterior than the normal slopes reported in the literature for adults (7.2 to 10.7 degrees, P=0.0001) and children (10 to 11 degrees, P=0.0001). The Pearson correlation coefficient for mean tibial slope and age showed negative correlations of -0.4011 and -0.4335 for left and right knees, respectively. This anterior tibial slope produces proximal and posterior vector force components, which may shift the knee posteriorly in weightbearing. The mean tibial slope is significantly more anterior in patients with achondroplasia than in the general population; however, this difference diminishes as patients' age. An anterior tibial slope may predispose to a more posterior

  3. Total knee arthroplasty in patients with a prior fracture of the tibial plateau.

    PubMed

    Weiss, Nicholas G; Parvizi, Javad; Trousdale, Robert T; Bryce, Rex D; Lewallen, David G

    2003-02-01

    A fracture of the tibial plateau may predispose the knee to the development of posttraumatic arthritis. Malunion, intra-articular chondro-osseous defects, limb malalignment, retained internal fixation devices, and poor surrounding soft tissues may in turn compromise the outcome of total knee arthroplasty. The aim of our study was to evaluate the results of total knee arthroplasty in patients with a previous fracture of the tibial plateau. The results of sixty-two condylar total knee arthroplasties performed with cement, from 1988 to 1999, in sixty-two patients with a previous fracture of the tibial plateau were reviewed. The fracture of the tibial plateau had been treated by open reduction and internal fixation in thirty-eight knees, external fixation in one knee, and nonoperatively in twenty-three knees. There were forty women and twenty-two men with an average age of sixty-three years at the time of the arthroplasty. Knee Society scores were recorded preoperatively and at the time of follow-up, at an average of 4.7 years, and complications were noted. No patient was lost to follow-up. The mean Knee Society scores improved significantly (p < 0.0001), from 43.9 points for pain and 52 points for function preoperatively to 82.9 and 84 points, respectively, at the time of the latest follow-up. There were thirteen reoperations, which included manipulation with the patient under anesthesia (five knees), wound revision (three knees), and component revision (five knees). There were six intraoperative complications (10%). A postoperative complication occurred in sixteen knees (26%). The vast majority of patients treated with total knee arthroplasty after a previous fracture of the tibial plateau have substantial improvement in function and relief of pain. However, these patients are at increased risk for perioperative complications, as evidenced by the high reoperation rate of 21% in this study.

  4. Effects of diabetic peripheral neuropathy on gait in vascular trans-tibial amputees.

    PubMed

    Nakajima, Hiroshi; Yamamoto, Sumiko; Katsuhira, Junji

    2018-07-01

    Patients with diabetes often develop diabetic peripheral neuropathy, which is a distal symmetric polyneuropathy, so foot function on the non-amputated side is expected to affect gait in vascular trans-tibial amputees. However, there is little information on the kinematics and kinetics of gait or the effects of diabetic peripheral neuropathy in vascular trans-tibial amputees. This study aimed to clarify these effects, including the biomechanics of the ankle on the non-amputated side. Participants were 10 vascular trans-tibial amputees with diabetic peripheral neuropathy (group V) and 8 traumatic trans-tibial amputees (group T). Each subject's gait was analyzed at a self-selected speed using a three-dimensional motion analyzer and force plates. Ankle plantarflexion angle, heel elevation angle, and peak and impulse of anterior ground reaction force were smaller on the non-amputated side during pre-swing in group V than in group T. Center of gravity during pre-swing on the non-amputated side was lower in group V than in group T. Hip extension torque during loading response on the prosthetic side was greater in group V than in group T. These findings suggest that the biomechanical function of the ankle on the non-amputated side during pre-swing is poorer in vascular trans-tibial amputees with DPN than in traumatic trans-tibial amputees; the height of the center of gravity could not be maintained during this phase in vascular trans-tibial amputees with diabetic peripheral neuropathy. The hip joint on the prosthetic side compensated for this diminished function at the ankle during loading response. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Avulsion of the tibial tuberosity in a litter of greyhound puppies.

    PubMed

    Skelly, C M; McAllister, H; Donnelly, W J

    1997-10-01

    Avulsion of the tibial tuberosity was diagnosed in six of seven greyhound littermates aged five and a half months. The puppies showed hindlimb lameness of varying severity. Radiological assessment of affected stifle joints revealed partial or complete avulsion of the tibial tuberosities. In four puppies the lesions were bilateral. Euthanasia of the two most severely affected puppies was performed; the changes observed on histopathological examination of their cranioproximal tibiae suggested that the underlying lesion was that of osteochondrosis. A hereditary predisposition in greyhounds to osteochondrosis of the physis between the apophysis and the cranioproximal tibial diaphysis is postulated.

  6. Automated Measurement of Patient-Specific Tibial Slopes from MRI

    PubMed Central

    Amerinatanzi, Amirhesam; Summers, Rodney K.; Ahmadi, Kaveh; Goel, Vijay K.; Hewett, Timothy E.; Nyman, Edward

    2017-01-01

    Background: Multi-planar proximal tibial slopes may be associated with increased likelihood of osteoarthritis and anterior cruciate ligament injury, due in part to their role in checking the anterior-posterior stability of the knee. Established methods suffer repeatability limitations and lack computational efficiency for intuitive clinical adoption. The aims of this study were to develop a novel automated approach and to compare the repeatability and computational efficiency of the approach against previously established methods. Methods: Tibial slope geometries were obtained via MRI and measured using an automated Matlab-based approach. Data were compared for repeatability and evaluated for computational efficiency. Results: Mean lateral tibial slope (LTS) for females (7.2°) was greater than for males (1.66°). Mean LTS in the lateral concavity zone was greater for females (7.8° for females, 4.2° for males). Mean medial tibial slope (MTS) for females was greater (9.3° vs. 4.6°). Along the medial concavity zone, female subjects demonstrated greater MTS. Conclusion: The automated method was more repeatable and computationally efficient than previously identified methods and may aid in the clinical assessment of knee injury risk, inform surgical planning, and implant design efforts. PMID:28952547

  7. Comparison of tibial shaft ski fractures in children and adults.

    PubMed

    Hamada, Tomo; Matsumoto, Kazu; Ishimaru, Daichi; Sumi, Hiroshi; Shimizu, Katsuji

    2014-09-01

    To examine whether child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures. Descriptive epidemiological study. Prospectively analyzed the epidemiologic factors, injury types, and injury mechanisms at Sumi Memorial Hospital. This study analyzed information obtained from 276 patients with tibial fractures sustained during skiing between 2004 and 2012. We focused on 174 ski-related tibial shaft fractures with respect to the following factors: age, gender, laterality of fracture, skill level, mechanism of fracture (fall vs collision), scene of injury (steepness of slope), snow condition, and weather. Fracture pattern was graded according to Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification and mechanical direction [external (ER) or internal rotation (IR)]. Tibial shaft fractures were the most common in both children (89.3%) and adults (47.4%). There were no significant differences in gender, side of fracture, mechanism of fracture, snow condition, or weather between children and adults. Skill levels were significantly lower in children than in adults (P < 0.0001). Type A fractures were more dominant in children (73 cases, 72.3%) than in adults (39 cases, 53.4%). There was significantly more ER in children than in adults (P < 0.0001). Among children, female patients had significantly more IR than ER; in contrast, among adults, women were injured by ER. We found significant differences in some of these parameters, suggesting that child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures.

  8. Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.

    PubMed

    Burchard, Rene; Katerla, Denise; Hammer, Marina; Pahlkötter, Anke; Soost, Christian; Dietrich, Gerhard; Ohrndorf, Arne; Richter, Wolfgang; Lengsfeld, Markus; Christ, Hans-Jürgen; Graw, Jan Adriaan; Fritzen, Claus-Peter

    2018-02-01

    Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant. Therefore, the stability of two different intramedullary nails, a short implant used in humeral fractures and a long device used in tibial fractures for stabilization in valgus HTOs, was investigated as an alternative fixation technique. The plate fixator was defined as reference standard. Nine synthetic tibia models were standardly osteotomized and stabilized by one of the fixation devices. Axial compression was realized using a special testing machine and two protocols were performed: a multi-step fatigue test and a load-to-failure test. Overall motion, medial, and lateral displacements were documented. Fractures always occurred at the lateral cortex. Axial cyclic loading up to 800 N was tolerated by all implants without failure. The tibia nail provided highest fatigue strength under the load-to-failure conditions. The results suggest that intramedullary nailing might be used as an alternative concept in HTO.

  9. Long-term complications following tibial plateau levelling osteotomy in small dogs with tibial plateau angles > 30°.

    PubMed

    Knight, Rebekah; Danielski, Alan

    2018-04-21

    Tibial plateau levelling osteotomy (TPLO) is commonly performed for surgical management of cranial cruciate ligament (CCL) disease. It has been suggested that small dogs may have steeper tibial plateau angles (TPAs) than large dogs, which has been associated with increased complication rates after TPLO. A retrospective study was performed to assess the rate and nature of long-term complications following TPLO in small dogs with TPAs>30°. Medical records were reviewed for dogs with TPAs>30° treated for CCL rupture by TPLO with a 2.0 mm plate over a five-year period. Radiographs were assessed to determine TPA, postoperative tibial tuberosity width and to identify any complication. Up-to-date medical records were obtained from the referring veterinary surgeon and any complications in the year after surgery were recorded. The effects of different variables on complication rate were assessed using logistic regression analysis. Minor complications were reported in 22.7 per cent of cases. This is similar to or lower than previously reported complication rates for osteotomy techniques in small dogs and dogs with steep TPAs. A smaller postoperative TPA was the only variable significantly associated with an increased complication rate. No major complications were identified. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. What Components Comprise the Measurement of the Tibial Tuberosity-Trochlear Groove Distance in a Patellar Dislocation Population?

    PubMed

    Tensho, Keiji; Akaoka, Yusuke; Shimodaira, Hiroki; Takanashi, Seiji; Ikegami, Shota; Kato, Hiroyuki; Saito, Naoto

    2015-09-02

    The tibial tuberosity-trochlear groove distance is used as an indicator for medial tibial tubercle transfer; however, to our knowledge, no studies have verified whether this distance is strongly affected by tubercle lateralization at the proximal part of the tibia. We hypothesized that the tibial tuberosity-trochlear groove distance is mainly affected by tibial tubercle lateralization at the proximal part of the tibia. Forty-four patients with a history of patellar dislocation and forty-four age and sex-matched controls were analyzed with use of computed tomography. The tibial tuberosity-trochlear groove distance, tibial tubercle lateralization, trochlear groove medialization, and knee rotation were measured and were compared between the patellar dislocation group and the control group. The association between the tibial tuberosity-trochlear groove distance and three other parameters was calculated with use of the Pearson correlation coefficient and partial correlation analysis. There were significant differences in the tibial tuberosity-trochlear groove distance (p < 0.001) and knee rotation (p < 0.001), but there was no difference in the tibial tubercle lateralization (p = 0.13) and trochlear groove medialization (p = 0.08) between the patellar dislocation group and the control group. The tibial tuberosity-trochlear groove distance had no linear correlation with tubercle lateralization (r = 0.21) or groove medialization (r = -0.15); however, knee rotation had a good positive correlation in the patellar dislocation group (r = 0.62). After adjusting for the remaining parameters, knee rotation strongly correlated with the tibial tuberosity-trochlear groove distance (r = 0.69, p < 0.001), whereas tubercle lateralization showed moderate significant correlations in the patellar dislocation group (r = 0.42; p = 0.005). Because the tibial tuberosity-trochlear groove distance is affected more by knee rotation than by tubercle malposition, its use as an indicator for

  11. Standing balance in people with trans-tibial amputation due to vascular causes: A literature review.

    PubMed

    Seth, Mayank; Lamberg, Eric

    2017-08-01

    Balance is an important variable to consider during the rehabilitation process of individuals with trans-tibial amputation. Limited evidence exists on the balance abilities of people with trans-tibial amputation due to vascular causes. The purpose of this article is to review literature and determine if standing balance is diminished in people with trans-tibial amputation due to vascular causes. Literature review. Data were obtained from PubMed, Google Scholar, OandP.org , CINHAL, and Science Direct. Studies were selected only if they included standing balance assessment of people with unilateral trans-tibial amputation due to vascular causes. The review yielded seven articles that met the inclusion criteria. The general test methodology required participants to stand still on force platforms, with feet together, while center of pressure or postural sway was recorded. According to the findings of this review, individuals with trans-tibial amputees due to vascular causes have diminished balance abilities. Limited evidence suggests their balance might be further diminished as compared to individuals with trans-tibial amputation due to trauma. Although the evidence is limited, because of the underlying pathology and presence of comorbidities in individuals with trans-tibial amputation due to vascular causes, one cannot ignore these findings, as even a minor injury from a fall may develop into a non-healing ulcer and affect their health and well-being more severely than individuals with trans-tibial amputation due to trauma. Clinical relevance Individuals with trans-tibial amputation due to vascular causes have diminished balance abilities compared to healthy individuals and individuals with trans-tibial amputation due to trauma. This difference should be considered when designing and fabricating prostheses. Prosthetists and rehabilitation clinicians should consider designing amputation cause-specific rehabilitation interventions, focussing on balance and other

  12. Segmental transports for posttraumatic lower extremity bone defects: are femoral bone transports safer than tibial?

    PubMed

    Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Ettinger, Max; Jagodzinski, Michael; Hankemeier, Stefan

    2011-02-01

    The long-term outcomes following femoral and tibial segment transports are not well documented. Purpose of the study is to compare the complication rates and life quality scores of femoral and tibial transports in order to find what are the complication rates of femoral and tibial monorail bone transports and if they are different? We retrospectively analyzed the medical records of 8 femoral and 14 tibial consecutive segment transports performed with the monorail technique between 2001 and 2008 in our institution. Mean follow-up was 5.1 ± 2.1 years with a minimum follow-up of 2 years. Aetiology of the defects was posttraumatic in all cases. Four femoral (50%) and nine tibial (64%) fractures were open. The Short Form-36 (SF-36) health survey was used to compare the life quality after femoral and tibial bone transports. The Mann-Whiney U test, Fisher exact test, and the Student's two tailed t-test were used for statistical analysis. P ≤ 0.05 was considered to be statistically significant. The tibial transport was associated with higher rates of severe complications and additional procedures (1.5 ± 0.9 vs. 3.4 ± 2.7, p = 0.048). Three patients of the tibial group were amputated because of recurrent infections and one developed a complete regenerate insufficiency that was treated with partial diaphyseal tibial replacement. Contrary to that none of patients of the femoral group developed a complete regenerate insufficiency or was amputated. Tibial bone transports have a higher rate of complete and incomplete regenerate insufficiency and can more often end in an amputation. The authors suggest systematic weekly controls of the CRP value and of the callus formation in patients with posttraumatic tibia bone transports. Further comparative studies comparing the results of bone transports with and without intramedullary implants are necessary.

  13. Physeal growth arrest after tibial lengthening in achondroplasia: 23 children followed to skeletal maturity.

    PubMed

    Song, Sang-Heon; Agashe, Mandar Vikas; Huh, Young-Jae; Hwang, Soon-Young; Song, Hae-Ryong

    2012-06-01

    Bilateral tibial lengthening has become one of the standard treatments for upper segment-lower segment disproportion and to improve quality of life in achondroplasia. We determined the effect of tibial lengthening on the tibial physis and compared tibial growth that occurred at the physis with that in non-operated patients with achondroplasia. We performed a retrospective analysis of serial radiographs until skeletal maturity in 23 achondroplasia patients who underwent bilateral tibial lengthening before skeletal maturity (lengthening group L) and 12 achondroplasia patients of similar height and age who did not undergo tibial lengthening (control group C). The mean amount of lengthening of tibia in group L was 9.2 cm (lengthening percentage: 60%) and the mean age at the time of lengthening was 8.2 years. The mean duration of follow-up was 9.8 years. Skeletal maturity (fusion of physis) occurred at 15.2 years in group L and at 16.0 years in group C. The actual length of tibia (without distraction) at skeletal maturity was 238 mm in group L and 277 mm in group C (p = 0.03). The mean growth rates showed a decrease in group L relative to group C from about 2 years after surgery. Physeal closure was most pronounced on the anterolateral proximal tibial physis, with relative preservation of the distal physis. Our findings indicate that physeal growth rate can be disturbed after tibial lengthening in achondroplasia, and a close watch should be kept for such an occurrence-especially when lengthening of more than 50% is attempted.

  14. Chronic shin splints. Classification and management of medial tibial stress syndrome.

    PubMed

    Detmer, D E

    1986-01-01

    A clinical classification and treatment programme has been developed for chronic medial tibial stress syndrome. Medial tibial stress syndrome has been reported to be either tibial stress fracture or microfracture, tibial periostitis, or distal deep posterior chronic compartment syndrome. Three chronic types exist and may coexist: Type I (tibial microfracture, bone stress reaction or cortical fracture); type II (periostalgia from chronic avulsion of the periosteum at the periosteal-fascial junction); and type III (chronic compartment syndrome syndrome). Type I disease is treated nonoperatively. Operations for resistant types II and III medial tibial stress syndrome were performed in 41 patients. Bilaterality was common (type II, 50% type III, 88%). Seven had coexistent type II/III; one had type I/II. Preoperative symptoms averaged 24 months in type II, 6 months in type III, and 33 months in types II/III. Mean age was 22 years (15 to 51). Resting compartment pressures were normal in type II (mean 12 mm Hg) and elevated in type III and type II/III (mean 23 mm Hg). Type II and type II/III patients received fasciotomy plus periosteal cauterisation. Type III patients had fasciotomy only. All procedures were performed on an outpatient basis using local anaesthesia. Follow up was complete and averaged 6 months (2 to 14 months). Improved performance was as follows: type II, 93%, type III, 100%; type II/III, 86%. Complete cures were as follows: type II, 78%; type III, 75%; and type II/III, 57%. This experience suggests that with precise diagnosis and treatment involving minimal risk and cost the athlete has a reasonable chance of return to full activity.

  15. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  16. Pathomorphism of spiral tibial fractures in computed tomography imaging.

    PubMed

    Guzik, Grzegorz

    2011-01-01

    Spiral fractures of the tibia are virtually homogeneous with regard to their pathomorphism. The differences that are seen concern the level of fracture of the fibula, and, to a lesser extent, the level of fracture of the tibia, the length of fracture cleft, and limb shortening following the trauma. While conventional radiographs provide sufficient information about the pathomorphism of fractures, computed tomography can be useful in demonstrating the spatial arrangement of bone fragments and topography of soft tissues surrounding the fracture site. Multiple cross-sectional computed tomography views of spiral fractures of the tibia show the details of the alignment of bone chips at the fracture site, axis of the tibial fracture cleft, and topography of soft tissues that are not visible on standard radiographs. A model of a spiral tibial fracture reveals periosteal stretching with increasing spiral and longitudinal displacement. The cleft in tibial fractures has a spiral shape and its line is invariable. Every spiral fracture of both crural bones results in extensive damage to the periosteum and may damage bellies of the long flexor muscle of toes, flexor hallucis longus as well as the posterior tibial muscle. Computed tomography images of spiral fractures of the tibia show details of damage that are otherwise invisible on standard radiographs. Moreover, CT images provide useful information about the spatial location of the bone chips as well as possible threats to soft tissues that surround the fracture site. Every spiral fracture of the tibia is associated with disruption of the periosteum. 1. Computed tomography images of spiral fractures of the tibia show details of damage otherwise invisible on standard radiographs, 2. The sharp end of the distal tibial chip can damage the tibialis posterior muscle, long flexor muscles of the toes and the flexor hallucis longus, 3. Every spiral fracture of the tibia is associated with disruption of the periosteum.

  17. Sequential avulsions of the tibial tubercle in an adolescent basketball player.

    PubMed

    Huang, Ying Chieh; Chao, Ying-Hao; Lien, Fang-Chieh

    2010-05-01

    Tibial tubercle avulsion is an uncommon fracture in physically active adolescents. Sequential avulsion of tibial tubercles is extremely rare. We reported a healthy, active 15-year-old boy who suffered from left tibial tubercle avulsion fracture during a basketball game. He received open reduction and internal fixation with two smooth Kirschner wires and a cannulated screw, with every effort to reduce the plate injury. Long-leg splint was used for protection followed by programmed rehabilitation. He recovered uneventfully and returned to his previous level of activity soon. Another avulsion fracture happened at the right tibial tubercle 3.5 months later when he was playing the basketball. From the encouragement of previous successful treatment, we provided him open reduction and fixation with two small-caliber screws. He recovered uneventfully and returned to his previous level of activity soon. No genu recurvatum or other deformity was happening in our case at the end of 2-year follow-up. No evidence of Osgood-Schlatter disease or osteogenesis imperfecta was found. Sequential avulsion fractures of tibial tubercles are rare. Good functional recovery can often be obtained like our case if we treat it well. To a physically active adolescent, we should never overstate the risk of sequential avulsion of the other leg to postpone the return to an active, functional life.

  18. High-quality nonpolar a-plane GaN epitaxial films grown on r-plane sapphire substrates by the combination of pulsed laser deposition and metal–organic chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Yang, Weijia; Zhang, Zichen; Wang, Wenliang; Zheng, Yulin; Wang, Haiyan; Li, Guoqiang

    2018-05-01

    High-quality a-plane GaN epitaxial films have been grown on r-plane sapphire substrates by the combination of pulsed laser deposition (PLD) and metal–organic chemical vapor deposition (MOCVD). PLD is employed to epitaxial growth of a-plane GaN templates on r-plane sapphire substrates, and then MOCVD is used. The nonpolar a-plane GaN epitaxial films with relatively small thickness (2.9 µm) show high quality, with the full-width at half-maximum values of GaN(11\\bar{2}0) along [1\\bar{1}00] direction and GaN(10\\bar{1}1) of 0.11 and 0.30°, and a root-mean-square surface roughness of 1.7 nm. This result is equivalent to the quality of the films grown by MOCVD with a thickness of 10 µm. This work provides a new and effective approach for achieving high-quality nonpolar a-plane GaN epitaxial films on r-plane sapphire substrates.

  19. All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes.

    PubMed

    Tang, Fan; Zhou, Yong; Zhang, Wenli; Min, Li; Shi, Rui; Luo, Yi; Duan, Hong; Tu, Chongqi

    2017-04-04

    Whether all-polyethylene tibial (APT) components are beneficial to patients who received distal femur limb-salvage surgery lacks high-quality clinical follow-up and mechanical evidence. This study aimed to investigate the biomechanics of the distal femur reconstructed with APT tumor knee prostheses using finite element (FE) analysis based on our previous, promising clinical outcome. Three-dimensional FE models that use APT and metal-backed tibial (MBT) prostheses to reconstruct distal femoral bone defects were developed and input into the Abaqus FEA software version 6.10.1. Mesh refinement tests and gait simulation with a single foot both in the upright and 15°-flexion positions with mechanical loading were conducted. Stress distribution analysis was compared between APT and MBT at the two static positions. For both prosthesis types, the stress was concentrated on the junction of the stem and shaft, and the maximum stress in the femoral axis base was more than 100 Mpa. The stress on the tibial surface was relatively distributed, which was 1-19 MPa. The stress on the tibial bone-cement layer of the APT prosthesis was approximately 20 times higher than that on the MBT prosthesis in the same region. The stress on the proximal tibial cancellous bone and cortical bone of the APT prosthesis was 3-5 times greater than that of the MBT prosthesis, and it was more distributed. Although the stress of bone-cement around the APT component is relatively high, the stress was better distributed at the polyethylene-cement-bone interface in APT than in MBT prosthesis, which effectively protects the proximal tibia in distal femur tumor knee prosthesis replacement. These results should be considered when selecting the appropriate tibial component for a patient, especially under the foreseeable conditions of osteoporosis.

  20. Treatment of large posttraumatic tibial bone defects using the Ilizarov method: a subjective outcome assessment.

    PubMed

    Krappinger, Dietmar; Irenberger, Alexander; Zegg, Michael; Huber, Burkhart

    2013-06-01

    The treatment of large posttraumatic tibial bone defects using the Ilizarov method was shown to be successful in several studies. These studies, however, typically focus on the radiological and functional outcome using objective parameters only. The aim of the present study was therefore to assess the objective and subjective outcome of a consecutive series of patients with large posttraumatic tibial bone defects using the Ilizarov method. Additionally, it was our goal to assess the physical and mental stress for the patients and their relatives during the long treatment period and the general health status at final follow-up. A consecutive series of 15 patients with posttraumatic tibial bone defects of >30 mm after sustaining open tibial fractures and failure of internal fixation was included. The objective outcome was assessed at final follow-up using Paley's criteria. For the assessment of the subjective outcome, all patients were asked to evaluate their satisfaction with the function of the lower leg, the cosmetic appearance and overall outcome as well. The physical and mental stress of the treatment for the patients and the nearest relative of patients were assessed at the time of frame removal using a custom-made questionnaire. The SF-36 was used to evaluate the general health status at final follow-up. Solid bone union with stable soft tissue coverage and eradication of infection was achieved in all patients despite a high complication rate. The functional outcome at final follow-up was excellent or good in all patients. The patients' satisfaction with the overall outcome and the function of the lower extremity was high as well. The fear of amputation and complications was the major subjective burden for both the patients and their relatives. The long external fixation time is another relevant issue. The Ilizarov method is a safe option for the treatment of large posttraumatic tibial bone defects after failure of internal fixation despite the high

  1. The Lateral Meniscus as a Guide to Anatomical Tibial Tunnel Placement During Anterior Cruciate Ligament Reconstruction.

    PubMed

    Kassam, A M; Tillotson, L; Schranz, P J; Mandalia, V I

    2015-01-01

    The aim of the study is to show, on an MRI scan, that the posterior border of the anterior horn of the lateral meniscus (AHLM) could guide tibial tunnel position in the sagittal plane and provide anatomical graft position. One hundred MRI scans were analysed with normal cruciate ligaments and no evidence of meniscal injury. We measured the distance between the posterior border of the AHLM and the midpoint of the ACL by superimposing sagittal images. The mean distance between the posterior border of the AHLM and the ACL midpoint was -0.1mm (i.e. 0.1mm posterior to the ACL midpoint). The range was 5mm to -4.6mm. The median value was 0.0mm. 95% confidence interval was from -0.5 to 0.3mm. A normal, parametric distribution was observed and Intra- and inter-observer variability showed significant correlation (p<0.05) using Pearsons Correlation test (intra-observer) and Interclass correlation (inter-observer). Using the posterior border of the AHLM is a reproducible and anatomical marker for the midpoint of the ACL footprint in the majority of cases. It can be used intra-operatively as a guide for tibial tunnel insertion and graft placement allowing anatomical reconstruction. There will inevitably be some anatomical variation. Pre-operative MRI assessment of the relationship between AHLM and ACL footprint is advised to improve surgical planning. Level 4.

  2. Flat midsubstance of the anterior cruciate ligament with tibial "C"-shaped insertion site.

    PubMed

    Siebold, Rainer; Schuhmacher, Peter; Fernandez, Francis; Śmigielski, Robert; Fink, Christian; Brehmer, Axel; Kirsch, Joachim

    2015-11-01

    This anatomical cadaver study was performed to investigate the flat appearance of the midsubstance shape of the anterior cruciate ligament (ACL) and its tibial "C"-shaped insertion site. The ACL midsubstance and the tibial ACL insertion were dissected in 20 cadaveric knees (n = 6 fresh frozen and n = 14 paraffined). Magnifying spectacles were used for all dissections. Morphometric measurements were performed using callipers and on digital photographs. In all specimens, the midsubstance of the ACL was flat with a mean width of 9.9 mm, thickness of 3.9 mm and cross-sectional area of 38.7 mm(2). The "direct" "C"-shaped tibial insertion runs from along the medial tibial spine to the anterior aspect of the lateral meniscus. The mean width (length) of the "C" was 12.6 mm, its thickness 3.3 mm and area 31.4 mm(2). The centre of the "C" was the bony insertion of the anterior root of the lateral meniscus overlayed by fat and crossed by the ACL. No posterolateral (PL) inserting ACL fibres were found. Together with the larger "indirect" part (area 79.6 mm(2)), the "direct" one formed a "duck-foot"-shaped footprint. The tibial ACL midsubstance and tibial "C"-shaped insertion are flat and are resembling a "ribbon". The centre of the "C" is the bony insertion of the anterior root of the lateral meniscus. There are no central or PL inserting ACL fibres. Anatomical ACL reconstruction may therefore require a flat graft and a "C"-shaped tibial footprint reconstruction with an anteromedial bone tunnel for single bundle and an additional posteromedial bone tunnel for double bundle.

  3. Medial tibial pain. A prospective study of its cause among military recruits.

    PubMed

    Milgrom, C; Giladi, M; Stein, M; Kashtan, H; Margulies, J; Chisin, R; Steinberg, R; Swissa, A; Aharonson, Z

    1986-12-01

    In a prospective study of 295 infantry recruits during 14 weeks of basic training, 41% had medial tibial pain. Routine scintigraphic evaluation in cases of medial tibial bone pain showed that 63% had abnormalities. A stress fracture was found in 46%. Only two patients had periostitis. None had ischemic medial compartment syndrome. Physical examination could not differentiate between cases with medial tibial bone pain secondary to stress fractures and those with scintigraphically normal tibias. When both pain and swelling were localized in the middle one-third of the tibia, the lesion most likely proved to be a stress fracture.

  4. [Mobility of a polyethylene tibial insert in a mobile total knee prosthesis].

    PubMed

    Castel, E; Roger, B; Camproux, A; Saillant, G

    1999-03-01

    We have studied the mobility of a mobile tibial implant in total knee arthroplasty (TKA) by a radiographical evaluation. We analyzed mobility of the polyethylene tibial insert of 15 "G2S" TKA implanted for one year or more. We established a dynamic radiographical evaluation. We used 3 weight-bearing radiographs: AP in extension and two lateral (one in extension and one at 90 degrees of flexion), two AP with femoral internal and external rotation, 2 strict lateral X-rays in neutral rotation in antero-posterior replacement with a 25 kilograms strength Telos, and 2 AP in varus and valgus with Telos. Wilcoxon's test and Fisher's exact test were used for statistical evaluation. Our study demonstrated preservation of the polyethylene mobility in tibial TKA implant in all movements: in rotation, in antero-posterior translation with Telos, and even in antero-posterior translation during physiological condition with flexion-extension weight-bearing radiographs. Statistical tests were very significant. We noticed that flexion induced anterior translation of tibial polyethylene when PCL was preserved. This study answered to our question whether mobility of TKA tibial implant persists after implantation. This mobility should reduce loosening forces to the tibia and stress in the polyethylene component. Now we have to determine the amplitude of mobility required to reach this objective.

  5. Frontal plane stability following UKA in a biomechanical study.

    PubMed

    Heyse, Thomas J; Tucker, Scott M; Rajak, Yogesh; Kia, Mohammad; Lipman, Joseph D; Imhauser, Carl W; Westrich, Geoffrey H

    2015-06-01

    Function and kinematics following unicondylar knee arthroplasty (UKA) have been reported to be close to the native knee. Gait, stair climbing and activities of daily living expose the knee joint to a combination of varus and valgus moments. Replacement of the medial compartment via UKA is likely to change the physiologic knee stability and its ability to respond to varus and valgus moments. It was hypothesized that UKA implantation would stiffen the knee and decrease range of motion in the frontal plane. Six fresh frozen cadaver knees were prepared and mounted in a six-degrees-of-freedom robot. An axial load of 200 N was applied with the knee in 15°, 45° and 90° of flexion. Varus and valgus moments were added, respectively, before and after implantation of medial UKA. Tests were than redone with a thicker polyethylene inlay to simulate overstuffing of the medial compartment. Range of motion in the frontal plane and the tibial response to moments were recorded via the industrial robot. The range of motion in the frontal plane was decreased with both, balanced and overstuffed UKA and shifted towards valgus. When exposed to valgus moments, knees following UKA were stiffer in comparison with the native knee. The effect was even more pronounced with medial overstuffing. In UKA, the compressive anatomy is replaced by much stiffer components. This lack of medial compression and relative overstuffing leads to a tighter medial collateral ligament. This drives the trend towards a stiffer joint as documented by a decrease in frontal plane range of motion. Overstuffing should strictly be avoided when performing UKA.

  6. Tibial and fibular nerves evaluation using intraoperative electromyography in rats.

    PubMed

    Nepomuceno, André Coelho; Politani, Elisa Landucci; Silva, Eduardo Guandelini da; Salomone, Raquel; Longo, Marco Vinicius Losso; Salles, Alessandra Grassi; Faria, José Carlos Marques de; Gemperli, Rolf

    2016-08-01

    To evaluate a new model of intraoperative electromyographic (EMG) assessment of the tibial and fibular nerves, and its respectives motor units in rats. Eight Wistar rats underwent intraoperative EMG on both hind limbs at two different moments: week 0 and week 12. Supramaximal electrical stimulation applied on sciatic nerve, and compound muscle action potential recorded on the gastrocnemius muscle (GM) and the extensor digitorum longus muscle (EDLM) through electrodes at specifics points. Motor function assessment was performaced through Walking Track Test. Exposing the muscles and nerves for examination did not alter tibial (p=0.918) or fibular (p=0.877) function between the evaluation moments. Electromyography of the GM, innervated by the tibial nerve, revealed similar amplitude (p=0.069) and latency (p=0.256) at week 0 and at 12 weeks, creating a standard of normality. Meanwhile, electromyography of the EDLM, innervated by the fibular nerve, showed significant differences between the amplitudes (p=0.003) and latencies (p=0.021) at the two different moments of observation. Intraoperative electromyography determined and quantified gastrocnemius muscle motor unit integrity, innervated by tibial nerve. Although this study was not useful to, objectively, assess extensor digitorum longus muscle motor unit, innervated by fibular nerve.

  7. Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

    NASA Technical Reports Server (NTRS)

    Giveona, Amir; Shaklan, Stuart; Kern, Brian; Noecker, Charley; Kendrick, Steve; Wallace, Kent

    2012-01-01

    In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

  8. Management of tibial fractures using a circular external fixator in two calves.

    PubMed

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  9. Tibial rotational osteotomy for idiopathic torsion. A comparison of the proximal and distal osteotomy levels.

    PubMed

    Krengel, W F; Staheli, L T

    1992-10-01

    A retrospective analysis was done of 52 rotational tibial osteotomies (RTOs) performed on 35 patients with severe idiopathic tibial torsion. Thirty-nine osteotomies were performed at the proximal or midtibial level. Thirteen were performed at the distal tibial level with a technique previously described by one of the authors. Serious complications occurred in five (13%) of the proximal and in none of the distal RTOs. For severe and persisting idiopathic tibial torsion, the authors recommend correction by RTO at the distal level. Proximal level osteotomy is indicated only when a varus or valgus deformity required concurrent correction.

  10. Global rotation has high sensitivity in ACL lesions within stress MRI.

    PubMed

    Espregueira-Mendes, João; Andrade, Renato; Leal, Ana; Pereira, Hélder; Skaf, Abdala; Rodrigues-Gomes, Sérgio; Oliveira, J Miguel; Reis, Rui L; Pereira, Rogério

    2017-10-01

    This study aims to objectively compare side-to-side differences of P-A laxity alone and coupled with rotatory laxity within magnetic resonance imaging, in patients with total anterior cruciate ligament (ACL) rupture. This prospective study enrolled sixty-one patients with signs and symptoms of unilateral total anterior cruciate ligament rupture, which were referred to magnetic resonance evaluation with simultaneous instrumented laxity measurements. Sixteen of those patients were randomly selected to also have the contralateral healthy knee laxity profile tested. Images were acquired for the medial and lateral tibial plateaus without pressure, with postero-anterior translation, and postero-anterior translation coupled with maximum internal and external rotation, respectively. All parameters measured were significantly different between healthy and injured knees (P < 0.05), with exception of lateral plateau without stress. The difference between injured and healthy knees for medial and lateral tibial plateaus anterior displacement (P < 0.05) and rotation (P < 0.001) was statistically significant. It was found a significant correlation between the global rotation of the lateral tibial plateau (lateral plateau with internal + external rotation) with pivot-shift, and between the anterior global translation of both tibial plateaus (medial + lateral tibial plateau) with Lachman. The anterior global translation of both tibial plateaus was the most specific test with a cut-off point of 11.1 mm (93.8 %), and the global rotation of the lateral tibial plateau was the most sensitive test with a correspondent cut-off point of 15.1 mm (92.9 %). Objective laxity quantification of ACL-injured knees showed increased sagittal laxity, and simultaneously in sagittal and transversal planes, when compared to their healthy contralateral knee. Moreover, when measuring instability from anterior cruciate ligament ruptures, the anterior global translation of both tibial plateaus

  11. Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty.

    PubMed

    Hernigou, Philippe; Deschamps, Gerard

    2004-03-01

    Laboratory studies have suggested that the sagittal displacements permitted by a knee replacement are influenced by the posterior slope of the tibial implant. The effect of the posterior slope of the tibial implant on the outcome of unicompartmental arthroplasty is not well known. The purpose of the present study was to assess the effect of the posterior slope on the long-term outcome of unicompartmental arthroplasty in knees with intact and deficient anterior cruciate ligaments. We retrospectively reviewed the results of ninety-nine unicompartmental arthroplasties after a mean duration of follow-up of sixteen years. At the time of the arthroplasty, the anterior cruciate ligament was considered to be normal in fifty knees, damaged in thirty-one, and absent in eighteen. At the most recent follow-up, we measured the posterior tibial slope and the anterior tibial translation on standing lateral radiographs. The anteroposterior stability of seventy-seven knees that had not been revised by the time of the most recent follow-up was evaluated clinically. In the group of seventy-seven knees that had not been revised by the time of the most recent follow-up, there was a significant linear relationship between anterior tibial translation (mean, 3.7 mm) and posterior tibial slope (mean, 4.3 degrees ) (p < 0.01). The mean posterior slope of the tibial implant was significantly less in the group of seventy-seven knees without loosening of the implant than it was in the group of seventeen knees with loosening of the implant (p < 0.05). Five ruptures of the anterior cruciate ligament occurred in knees in which the ligament had been considered to be normal at the time of implantation; the posterior tibial slope in these five knees was > or = 13 degrees. Clinical evaluation revealed normal or nearly normal anteroposterior stability at the time of the most recent follow-up in all sixty-six unrevised knees in which the anterior cruciate ligament had been present at the time of

  12. Immediate effects of modified landing pattern on a probabilistic tibial stress fracture model in runners.

    PubMed

    Chen, T L; An, W W; Chan, Z Y S; Au, I P H; Zhang, Z H; Cheung, R T H

    2016-03-01

    Tibial stress fracture is a common injury in runners. This condition has been associated with increased impact loading. Since vertical loading rates are related to the landing pattern, many heelstrike runners attempt to modify their footfalls for a lower risk of tibial stress fracture. Such effect of modified landing pattern remains unknown. This study examined the immediate effects of landing pattern modification on the probability of tibial stress fracture. Fourteen experienced heelstrike runners ran on an instrumented treadmill and they were given augmented feedback for landing pattern switch. We measured their running kinematics and kinetics during different landing patterns. Ankle joint contact force and peak tibial strains were estimated using computational models. We used an established mathematical model to determine the effect of landing pattern on stress fracture probability. Heelstrike runners experienced greater impact loading immediately after landing pattern switch (P<0.004). There was an increase in the longitudinal ankle joint contact force when they landed with forefoot (P=0.003). However, there was no significant difference in both peak tibial strains and the risk of tibial stress fracture in runners with different landing patterns (P>0.986). Immediate transitioning of the landing pattern in heelstrike runners may not offer timely protection against tibial stress fracture, despite a reduction of impact loading. Long-term effects of landing pattern switch remains unknown. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. How does tibial cartilage volume relate to symptoms in subjects with knee osteoarthritis?

    PubMed Central

    Wluka, A; Wolfe, R; Stuckey, S; Cicuttini, F

    2004-01-01

    Background: No consistent relationship between the severity of symptoms of knee osteoarthritis (OA) and radiographic change has been demonstrated. Objectives: To determine the relationship between symptoms of knee OA and tibial cartilage volume, whether pain predicts loss of cartilage in knee OA, and whether change in cartilage volume over time relates to change in symptoms over the same period. Method: 132 subjects with symptomatic, early (mild to moderate) knee OA were studied. At baseline and 2 years later, participants had MRI scans of their knee and completed questionnaires quantifying symptoms of knee OA (knee-specific WOMAC: pain, stiffness, function) and general physical and mental health (SF-36). Tibial cartilage volume was determined from the MRI images. Results: Complete data were available for 117 (89%) subjects. A weak association was found between tibial cartilage volume and symptoms at baseline. The severity of the symptoms of knee OA at baseline did not predict subsequent tibial cartilage loss. However, weak associations were seen between worsening of symptoms of OA and increased cartilage loss: pain (rs = 0.28, p = 0.002), stiffness (rs = 0.17, p = 0.07), and deterioration in function (rs = 0.21, p = 0.02). Conclusion: Tibial cartilage volume is weakly associated with symptoms in knee OA. There is a weak association between loss of tibial cartilage and worsening of symptoms. This suggests that although cartilage is not a major determinant of symptoms in knee OA, it does relate to symptoms. PMID:14962960

  14. Effect of ACL Transection on Internal Tibial Rotation in an in Vitro Simulated Pivot Landing

    PubMed Central

    Oh, Youkeun K.; Kreinbrink, Jennifer L.; Ashton-Miller, James A.; Wojtys, Edward M.

    2011-01-01

    Background: The amount of resistance provided by the ACL (anterior cruciate ligament) to axial tibial rotation remains controversial. The goal of this study was to test the primary hypotheses that ACL transection would not significantly affect tibial rotation under the large impulsive loads associated with a simulated pivot landing but would increase anterior tibial translation. Methods: Twelve cadaveric knees (mean age of donors [and standard deviation] at the time of death, 65.0 ± 10.5 years) were mounted in a custom testing apparatus to simulate a single-leg pivot landing. A compound impulsive load was applied to the distal part of the tibia with compression (∼800 N), flexion moment (∼40 N-m), and axial tibial torque (∼17 N-m) in the presence of five trans-knee muscle forces. A differential variable reluctance transducer mounted on the anteromedial aspect of the ACL measured relative strain. With the knee initially in 15° of flexion, and after five combined compression and flexion moment (baseline) loading trials, six trials were conducted with the addition of either internal or external tibial torque (internal or external loading), and then six baseline trials were performed. The ACL was then sectioned, six baseline trials were repeated, and then six trials of either the internal or the external loading condition, whichever had initially resulted in the larger relative ACL strain, were carried out. Tibiofemoral kinematics were measured optoelectronically. The results were analyzed with a nonparametric Wilcoxon signed-rank test. Results: Following ACL transection, the increase in the normalized internal tibial rotation was significant but small (0.7°/N-m ± 0.3°/N-m to 0.8°/N-m ± 0.3°/N-m, p = 0.012), while anterior tibial translation increased significantly (3.8 ± 2.9 to 7.0 ± 2.9 mm, p = 0.017). Conclusions: ACL transection leads to a small increase in internal tibial rotation, equivalent to a 13% decrease in the dynamic rotational resistance

  15. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures.

    PubMed

    Houben, I B; Raaben, M; Van Basten Batenburg, M; Blokhuis, T J

    2018-04-09

    The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16-89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p < 0.001). Correlation analysis yielded four possible confounders: infection requiring surgical intervention, fracture type, fasciotomy and open fractures. Logistic regression identified IWB as an independent predictor for impaired healing with an odds ratio of 1.13 per week delay (95% CI 1.03-1.25). Delay in initial weight bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. 3b.

  16. Canine stifle joint biomechanics associated with tibial plateau leveling osteotomy predicted by use of a computer model.

    PubMed

    Brown, Nathan P; Bertocci, Gina E; Marcellin-Little, Denis J

    2014-07-01

    To evaluate effects of tibial plateau leveling osteotomy (TPLO) on canine stifle joint biomechanics in a cranial cruciate ligament (CrCL)-deficient stifle joint by use of a 3-D computer model simulating the stance phase of gait and to compare biomechanics in TPLO-managed, CrCL-intact, and CrCL-deficient stifle joints. Computer simulations of the pelvic limb of a Golden Retriever. A previously developed computer model of the canine pelvic limb was used to simulate TPLO stabilization to achieve a tibial plateau angle (TPA) of 5° (baseline value) in a CrCL-deficient stifle joint. Sensitivity analysis was conducted for tibial fragment rotation of 13° to -3°. Ligament loads, relative tibial translation, and relative tibial rotation were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. TPLO with a 5° TPA converted cranial tibial translation to caudal tibial translation and increased loads placed on the remaining stifle joint ligaments, compared with results for a CrCL-intact stifle joint. Lateral collateral ligament load was similar, medial collateral ligament load increased, and caudal cruciate ligament load decreased after TPLO, compared with loads for a CrCL-deficient stifle joint. Relative tibial rotation after TPLO was similar to that of a CrCL-deficient stifle joint. Stifle joint biomechanics were affected by TPLO fragment rotation. In the model, stifle joint biomechanics were partially improved after TPLO, compared with CrCL-deficient stifle joint biomechanics, but TPLO did not fully restore CrCL-intact stifle joint biomechanics. Overrotation of the tibial fragment negatively influenced stifle joint biomechanics by increasing caudal tibial translation.

  17. Intraoperative study on anthropometry and gender differences of the proximal tibial plateau at the arthroplasty resection surface.

    PubMed

    Yang, Bo; Yu, Jiakuo; Gong, Xi; Chen, Lianxu; Wang, Yongjian; Wang, Jian; Wang, Haijun; Zhang, Jiying

    2014-01-01

    The tibial plateau is asymmetric with a larger medial plateau. We observed from clinical practice that the shape of the tibial plateau does not always present a larger medial plateau. Tibial plateau also showed other shapes. The purpose of this study was to analyze the anthropometric data of the proximal tibia in a large group of Chinese patients undergoing total knee arthroplasty and to investigate the morphology of the resected proximal tibial surface and its gender differences. A total of 822 knees (164 males, 658 females) from the Chinese population were measured intraoperatively for medial anteroposterior (MAP) and lateral anteroposterior (LAP) dimensions of the resected proximal tibial surface. The difference of MAP and LAP (DML) was also calculated as MAP minus LAP. We then classified the data into three groups based on the DML (<-2, -2 to 2, and >2 mm) to analyze the morphology of the proximal tibia and its distribution between male and female. The shape of proximal tibial plateau was of three types: larger medial plateau type, symmetric type, and larger lateral plateau type. There were significant differences between males and females in relation to the shape distribution of the proximal tibial plateau (P < 0.05). Most of the proximal tibial plateau was asymmetric, with 517 of 822 (62.9%) tibia having a DML >2 mm and 120 of 822 (14.6%) tibia having a DML<-2 mm. Only 185 of 822 (22.5%) tibia had a DML between -2 and 2 mm. The results of this study can be used as a guideline to design tibial components with different DMLs to better match the different anthropometry of the resected tibial surface.

  18. Multiple Osteochondral Allograft Transplantation with Concomitant Tibial Tubercle Osteotomy for Multifocal Chondral Disease of the Knee.

    PubMed

    Cotter, Eric J; Waterman, Brian R; Kelly, Mick P; Wang, Kevin C; Frank, Rachel M; Cole, Brian J

    2017-08-01

    Symptomatic patellofemoral chondral lesions are a challenging clinical entity, as these defects may result from persistent lateral patellar maltracking or repetitive microtrauma. Anteromedializing tibial tubercle osteotomy has been shown to be an effective strategy for primary and adjunctive treatment of focal or diffuse patellofemoral disease to improve the biomechanical loading environment. Similarly, osteochondral allograft transplantation has proven efficacy in physiologically young, high-demand patients with condylar or patellofemoral lesions, particularly without early arthritic progression. The authors present the surgical management of a young athlete with symptomatic tricompartmental focal chondral defects with fresh osteochondral allograft transplantation and anteromedializing tibial tubercle osteotomy.

  19. Comparison of the primary stability of different tibial baseplate concepts to retain both cruciate ligaments during total knee arthroplasty.

    PubMed

    Nowakowski, Andrej M; Stangel, Melanie; Grupp, Thomas M; Valderrabano, Victor

    2013-10-01

    A novel tibial baseplate design (Transversal Support Tibial Plateau) as a new treatment concept for bi-cruciate retaining total knee arthroplasty is evaluated for mechanical stability and compared to other tibial baseplate designs. This concept should provide better primary stability and thus, less subsidence, than implantation of two separate unicondylar tibial baseplates. Different baseplates were implanted into synthetic bone specimens (Sawbones® Pacific Research Laboratories, Inc., Washington, USA), all uncemented. Using a standardized experimental setup, subsidence was achieved, enabling comparison of the models regarding primary stability. Overall implant subsidence was significantly increased for the two separate unicondylar tibial baseplates versus the new Transversal Support Tibial Plateau concept, which showed comparable levels to a conventional tibial baseplate. Reduced subsidence results in better primary stability. Linking of two separate baseplates appears to provide increased primary stability in terms of bony fixation, comparable to that of a conventional single tibial baseplate. © 2013. Published by Elsevier Ltd. All rights reserved.

  20. The medial tibial stress syndrome. A cause of shin splints.

    PubMed

    Mubarak, S J; Gould, R N; Lee, Y F; Schmidt, D A; Hargens, A R

    1982-01-01

    The medial tibial stress syndrome is a symptom complex seen in athletes who complain of exercise-induced pain along the distal posterior-medial aspect of the tibia. Intramuscular pressures within the posterior compartments of the leg were measured in 12 patients with this disorder. These pressures were not elevated and therefore this syndrome is a not a compartment syndrome. Available information suggests that the medial tibial stress syndrome most likely represents a periostitis at this location of the leg.

  1. Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Bonatti, Hugo; Sabri, Saher

    2011-04-15

    Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

  2. Case report: comprehensive management of medial tibial stress syndrome

    PubMed Central

    Krenner, Bernard John

    2002-01-01

    Abstract Activity or exercise-induced leg pain is a common complication among competitive and “weekend warrior” athletes. Shin splints is a term that has been used to describe all lower leg pain as a result of activity. There are many different causes of “shin splints,” one of which is medial tibial stress syndrome, and the treating clinician must be aware of potentially serious causes of activity related leg pain. Restoring proper biomechanics to the entire kinetic chain and rehabilitation of the injured area should be the primary aim of treatment to optimize shock absorption. The role inflammation plays in medial tibial stress syndrome is controversial, but in this case, seemed to be a causative factor as symptomatology was dramatically decreased with the addition of proteolytic enzymes. Medial tibial stress syndrome can be quite difficult to treat and keeping athletes away from activities that will slow healing or aggravate the condition can be challenging. “Active” rest is the best way in which to allow proper healing while allowing the athlete to maintain their fitness. PMID:19674573

  3. High operating temperature interband cascade focal plane arrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Z.-B.; Godoy, S. E.; Kim, H. S.

    2014-08-04

    In this paper, we report the initial demonstration of mid-infrared interband cascade (IC) photodetector focal plane arrays with multiple-stage/junction design. The merits of IC photodetectors include low noise and efficient photocarrier extraction, even for zero-bias operation. By adopting enhanced electron barrier design and a total absorber thickness of 0.7 μm, the 5-stage IC detectors show very low dark current (1.10 × 10{sup −7} A/cm{sup 2} at −5 mV and 150 K). Even with un-optimized fabrication and standard commercial (mis-matched) read-out circuit technology, infrared images are obtained by the 320 × 256 IC focal plane array up to 180 K with f/2.3 optics. The minimum noise equivalent temperature differencemore » of 28 mK is obtained at 120 K. These initial results indicate great potential of IC photodetectors, particularly for high operating temperature applications.« less

  4. Bracing can partially limit tibial rotation during stressful activities after anterior crucial ligament reconstruction with a hamstring graft.

    PubMed

    Giotis, D; Paschos, N K; Zampeli, F; Pappas, E; Mitsionis, G; Georgoulis, A D

    2016-09-01

    Hamstring graft has substantial differences with BPTB graft regarding initial mechanical strength, healing sequence, and vascularization, which may imply that a different approach during rehabilitation period is required. The purpose of this study was to investigate the influence of knee bracing on tibial rotation in ACL-reconstructed patients with a hamstring autograft during high loading activities. The hypothesis was that there would be a decrease in tibial rotation in the ACL-reconstructed braced knee as compared to the unbraced knee. Twenty male patients having undergone unilateral ACL reconstruction with a semitendinosus/gracilis autograft were assessed. Kinematic data were collected with an eight-camera optoelectronic system during two stressful tasks: (1) descending from a stair and subsequent pivoting; and (2) landing from a platform and subsequent pivoting. In each patient, three different experimental conditions were evaluated: (A) wearing a prophylactic brace (braced condition); (B) wearing a patellofemoral brace (sleeved condition); (C) without brace (unbraced condition). The intact knee without brace served as a control. Tibial rotation was significantly lower in the intact knee compared to all three conditions of the ACL-reconstructed knee (P≤0.01 for both tasks). Presence of a brace or sleeve resulted in lower tibial rotation than in the unbraced condition (p=0.003 for descending/pivot and P=0.0004 for landing/pivot). The braced condition resulted in lower rotation than the sleeved condition for descending/pivoting (P=0.031) while no differences were found for landing/pivoting (P=0.230). Knee bracing limited the excessive tibial rotation during pivoting under high loading activities in ACL-reconstructed knees with a hamstring graft. This partial restoration of normal kinematics may have a potential beneficial effect in patients recovering from ACL reconstruction with a hamstring autograft. Level III, case-control therapeutic study. Copyright

  5. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    PubMed

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In

  6. Absolute S- and P-plane polarization efficiencies for high frequency holographic gratings in the VUV

    NASA Technical Reports Server (NTRS)

    Caruso, A. J.; Woodgate, B. E.; Mount, G. H.

    1981-01-01

    High frequency plane gratings (3500 and 3600 gr/mm) have been holographically ruled and blazed for the VUV spectral region. All gratings were coated with 70 nm Al + 25 nm MgF2. Absolute unpolarized and S- and P-plane polarization efficiencies have been measured for the first and second orders in the 120- to 450-nm spectral region at 18.5 and 30 deg angles of deviation. For deep grooves, anomalous features are more pronounced for the P-plane polarization efficiency than for the S-plane polarization efficiency. Holographic gratings can be tailored to produce high polarization or low polarization in the VUV. For comparison, efficiencies and polarization of the best conventional high frequency gratings were also determined. Measurements show that scattered light is significantly lower for holographic gratings in the VUV when compared with the conventional gratings.

  7. Metallic few-layered VS2 ultrathin nanosheets: high two-dimensional conductivity for in-plane supercapacitors.

    PubMed

    Feng, Jun; Sun, Xu; Wu, Changzheng; Peng, Lele; Lin, Chenwen; Hu, Shuanglin; Yang, Jinlong; Xie, Yi

    2011-11-09

    With the rapid development of portable electronics, such as e-paper and other flexible devices, practical power sources with ultrathin geometries become an important prerequisite, in which supercapacitors with in-plane configurations are recently emerging as a favorable and competitive candidate. As is known, electrode materials with two-dimensional (2D) permeable channels, high-conductivity structural scaffolds, and high specific surface areas are the indispensible requirements for the development of in-plane supercapacitors with superior performance, while it is difficult for the presently available inorganic materials to make the best in all aspects. In this sense, vanadium disulfide (VS(2)) presents an ideal material platform due to its synergic properties of metallic nature and exfoliative characteristic brought by the conducting S-V-S layers stacked up by weak van der Waals interlayer interactions, offering great potential as high-performance in-plane supercapacitor electrodes. Herein, we developed a unique ammonia-assisted strategy to exfoliate bulk VS(2) flakes into ultrathin VS(2) nanosheets stacked with less than five S-V-S single layers, representing a brand new two-dimensional material having metallic behavior aside from graphene. Moreover, highly conductive VS(2) thin films were successfully assembled for constructing the electrodes of in-plane supercapacitors. As is expected, a specific capacitance of 4760 μF/cm(2) was realized here in a 150 nm in-plane configuration, of which no obvious degradation was observed even after 1000 charge/discharge cycles, offering as a new in-plane supercapacitor with high performance based on quasi-two-dimensional materials.

  8. Ceramic hemi-unicondylar arthroplasty in an adolescent patient with idiopathic tibial chondrolysis.

    PubMed

    Dombroski, Derek; Garino, Jonathan; Lee, Gwo-Chin

    2009-06-01

    Despite recent advances in cartilage regeneration and restoration procedures, isolated, large, full-thickness cartilage lesions in young patients continue to pose significant challenges to patients and orthopedic surgeons. Treatment options for this difficult problem have traditionally included arthrodesis, osteotomy, osteochondral allograft, and prosthetic reconstruction. We present a case of an adolescent patient with isolated idiopathic lateral tibial chondrolysis treated with a custom ceramic hemi-unicondylar hemiarthroplasty. Preoperatively, a 3-dimensional computed tomography scan of the patient's knee was obtained to begin manufacturing a conforming custom ceramic insert that would articulate between the tibial base plate and the patient's native lateral femoral cartilage. Through a lateral parapatellar approach, the tibial preparation was carried out using the Zimmer M/G unicompartmental knee system (Warsaw, Indiana), and the tibial base plate was cemented into position in the standard fashion. A custom, conforming, prefabricated ceramic insert (CeramTec, Memphis, Tennessee) was then inserted onto the tibial base plate. At 5-year follow-up, this salvage procedure was successful in relieving pain and restoring function in this young patient. There were no signs of implant loosening or lysis. Magnetic resonance imaging of the knee at last follow-up revealed that the cartilage thickness of the patient's lateral femoral condyle remained unchanged. Unicondylar hemiarthroplasty performed in patients with large unipolar lesions in the knee can provide durable and reliable pain relief. Ceramic is a viable material that can be considered for articulation with native cartilage.

  9. Effect of tibial tuberosity advancement on femorotibial contact mechanics and stifle kinematics.

    PubMed

    Kim, Stanley E; Pozzi, Antonio; Banks, Scott A; Conrad, Bryan P; Lewis, Daniel D

    2009-01-01

    Objective- To evaluate the effects of tibial tuberosity advancement (TTA) on femorotibial contact mechanics and 3-dimensional kinematics in cranial cruciate ligament (CrCL)-deficient stifles of dogs. Study Design- In vitro biomechanical study. Animals- Unpaired pelvic limbs from 8 dogs, weighing 28-35 kg. Methods- Digital pressure sensors placed subjacent to the menisci were used to measure femorotibial contact force, contact area, peak and mean contact pressure, and peak pressure location with the limb under an axial load of 30% body weight and a stifle angle of 135 degrees . Three-dimensional static poses of the stifle were obtained using a Microscribe digitizing arm. Each specimen was tested under normal, CrCL-deficient, and TTA-treated conditions. Repeated measures analysis of variance with a Tukey post hoc test (P<.05) was used for statistical comparison. Results- Significant disturbances to all measured contact mechanic parameters were evident after CrCL transection, which corresponded to marked cranial tibial subluxation and internal tibial rotation in the CrCL-deficient stifle. No significant differences in any contact mechanic and kinematic parameters were detected between normal and TTA-treated stifles. Conclusion- TTA eliminates craniocaudal stifle instability during simulated weight-bearing and concurrently restores femorotibial contact mechanics to normal. Clinical Relevance- TTA may mitigate the progression of stifle osteoarthritis in dogs afflicted with CrCL insufficiency by eliminating cranial tibial thrust while preserving the normal orientation of the proximal tibial articulating surface.

  10. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    PubMed

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  11. The Lymphatic Response to Injury with Soft-Tissue Reconstruction in High-Energy Open Tibial Fractures of the Lower Extremity.

    PubMed

    van Zanten, Malou C; Mistry, Raakhi M; Suami, Hiroo; Campbell-Lloyd, Andrew; Finkemeyer, James P; Piller, Neil B; Caplash, Yugesh

    2017-02-01

    Severe compound tibial fractures are associated with extensive soft-tissue damage, resulting in disruption of lymphatic pathways that leave the patient at risk of developing chronic lymphedema. There are limited data on lymphatic response following lower limb trauma. Indocyanine green fluorescence lymphography is a novel, real-time imaging technique for superficial lymphatic mapping. The authors used this technique to image the superficial lymphatic vessels of the lower limbs in patients with severe compound tibial fracture. Baseline demographics and clinical and operative details were recorded in a prospective cohort of 17 patients who had undergone bone and soft-tissue reconstruction after severe compound tibial fracture between 2009 and 2014. Normal lymphatic images were obtained from the patients' noninjured limbs as a control. In this way, the authors investigated any changes to the normal anatomy of the lymphatic system in the affected limbs. Of the 17 patients, eight had free muscle flaps with split-thickness skin grafting, one had a free fasciocutaneous flap, one had a full-thickness skin graft, six had local fasciocutaneous flaps, and one had a pedicled gastrocnemius flap. None of the free flaps demonstrated any functional lymphatic vessels; the fasciocutaneous flaps and the skin graft demonstrated impaired lymphatic vessel function and dermal backflow pattern similar to that in lymphedema. Local flaps demonstrated lymphatic blockage at the scar edge. Severe compound fractures and the associated soft-tissue injury can result in significant lymphatic disruption and an increased risk for the development of chronic lymphedema.

  12. Association between foot type and tibial stress injuries: a systematic review.

    PubMed

    Barnes, A; Wheat, J; Milner, C

    2008-02-01

    To systematically review published articles investigating the association between structural foot characteristics and tibial stress injuries, and to suggest possible future avenues of research in this area. Literature was identified, selected and appraised in accordance with the methods of a systematic review. Articles potentially relevant to the research question were identified by searching the following electronic databases: Amed, Cinahl, Index to UK theses, Medline, PubMed, Scopus, Sports discus and Web of science. Duplicates were removed and, based on the title and abstract, the full text of relevant studies were retrieved. Two reviewers independently assessed papers; this formed the basis for the inclusion of the most appropriate trials. From the 479 articles originally identified, nine were deemed appropriate for inclusion in the review. In general, specific data relating to this relationship was limited. Outcomes of the nine investigations were difficult to compare due to differing methods used across studies. Results have proved conflicting, with limited evidence found to implicate any specific foot type as a potential risk factor for tibial stress injuries. No definitive conclusions can be drawn relating foot structure or function to an increased risk of tibial stress injuries. Extremes of foot types are likely to pose an increased risk of tibial stress injuries compared to normal arched feet.

  13. Higher Rate of Revision in PFC Sigma Primary Total Knee Arthroplasty With Mismatch of Femoro-Tibial Component Sizes.

    PubMed

    Young, Simon W; Clarke, Henry D; Graves, Stephen E; Liu, Yen-Liang; de Steiger, Richard N

    2015-05-01

    Total knee arthroplasty (TKA) systems permit a degree of femoro-tibial component size mismatch. The effect of mismatched components on revision rates has not been evaluated in a large study. We reviewed 21,906 fixed-bearing PFC Sigma primary TKAs using the Australian Orthopaedic Association National Joint Replacement Registry, dividing patients into three groups: no femoro-tibial size mismatch, tibial component size > femoral component size, and femoral component > tibial component. Revision rates were higher when the femoral size was greater than the tibia, compared to both equal size (HR = 1.20 (1.00, 1.45), P = 0.047) and to tibial size greater than femoral (HR = 1.60 (1.08, 2.37), P = 0.019). Potential mechanisms to explain these findings include edge loading of polyethylene and increased tibial component stresses. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Symptomatic venous thromboembolism following circular frame treatment for tibial fractures.

    PubMed

    Vollans, S; Chaturvedi, A; Sivasankaran, K; Madhu, T; Hadland, Y; Allgar, V; Sharma, H K

    2015-01-01

    Venous thromboembolism (VTE) is a significant cause of morbidity and mortality following tibial fractures. The risk is as high as 77% without prophylaxis and around 10% with prophylaxis. Within the current literature there are no figures reported specifically for those individuals treated with circular frames. Our aim was to evaluate the VTE incidence within a single surgeon series and to evaluate potential risk factors. We retrospectively reviewed our consecutive single surgeon series of 177 patients admitted to a major trauma unit with tibial fractures. All patients received standardised care, including chemical thromboprophylaxis within 24h of injury until independent mobility was achieved. We comprehensively reviewed our prospective database and medical records looking at demographics and potential risk factors. Seven patients (4.0% ± 2.87%) developed symptomatic VTE during the course of frame treatment; three deep vein thrombosis (DVTs) and four pulmonary embolisms (PEs). Those with a VTE event had significantly increased body mass index (BMI) (p = 0.01) when compared to those without symptomatic VTE. No differences (p > 0.05) were observed between the groups in age, gender, smoking status, fracture type (anatomical allocation or open/closed), delay to frame treatment, weight bearing status post-frame, inpatient stay or total duration of frame treatment. This study suggests that increased BMI is a statistically significant risk factor for VTE, as reported in current literature. In addition, we calculated the true risk of VTE following circular frame treatment for tibial fracture in our series is from 1.13% to 6.87%, which is at least comparable to other forms of treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Effect of Tibial Posterior Slope on Knee Kinematics, Quadriceps Force, and Patellofemoral Contact Force After Posterior-Stabilized Total Knee Arthroplasty.

    PubMed

    Okamoto, Shigetoshi; Mizu-uchi, Hideki; Okazaki, Ken; Hamai, Satoshi; Nakahara, Hiroyuki; Iwamoto, Yukihide

    2015-08-01

    We used a musculoskeletal model validated with in vivo data to evaluate the effect of tibial posterior slope on knee kinematics, quadriceps force, and patellofemoral contact force after posterior-stabilized total knee arthroplasty. The maximum quadriceps force and patellofemoral contact force decreased with increasing posterior slope. Anterior sliding of the tibial component and anterior impingement of the anterior aspect of the tibial post were observed with tibial posterior slopes of at least 5° and 10°, respectively. Increased tibial posterior slope contributes to improved exercise efficiency during knee extension, however excessive tibial posterior slope should be avoided to prevent knee instability. Based on our computer simulation we recommend tibial posterior slopes of less than 5° in posterior-stabilized total knee arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. [Investigation of tibial bones of the rats exposed on board "Spacelab-2":histomorphometric analysis

    NASA Technical Reports Server (NTRS)

    Durnova, G. N.; Kaplanskii, A. S.; Morey-Holton, E. R.; Vorobeva, V. N.

    1996-01-01

    Proximal metaphyses of tibial bones from the Sprague-Dowly rats exposed in US dedicated space life sciences laboratory SLS-2 for 13-14 days and sacrificed on day 13 in microgravity and within 5 hours and 14 days following recovery were the subject of histological, histochemical, and histomorphometric analyses. After the 13-day flight of SLS-2 the rats showed initial signs of osteopenia in the spongy tissue of tibial bones, secondary spongiosis affected first. Resorption of the secondary spongiosis was consequent to enhanced resorption and inhibition of osteogenesis. In rats sacrificed within 5 hours of recovery manifestations of tibial osteopenia were more evident than in rats sacrificed during the flight. Spaceflight-induced changes in tibial spongiosis were reverse by character the amount of spongy bone was fully compensated and following 14 days of readaptation to the terrestrial gravity.

  17. High accuracy in knee alignment and implant placement in unicompartmental medial knee replacement when using patient-specific instrumentation.

    PubMed

    Volpi, P; Prospero, E; Bait, C; Cervellin, M; Quaglia, A; Redaelli, A; Denti, M

    2015-05-01

    The influence of patient-specific instrumentations on the accuracy of unicompartmental medial knee replacement remains unclear. The goal of this study was to examine the ability of patient-specific instrumentation to accurately reproduce postoperatively what the surgeon had planned preoperatively. Twenty consecutive patients (20 knees) who suffered from isolated unicompartmental medial osteoarthritis of the knee and underwent medial knee replacement using newly introduced magnetic resonance imaging-based patient-specific instrumentation were assessed. This assessment recorded the following parameters: (1) the planned and the postoperative mechanical axis acquired through long-leg AP view radiographies; (2) the planned and the postoperative tibial slope acquired by means of standard AP and lateral view radiographies; and (3) the postoperative fit of the implanted components to the bone in coronal and sagittal planes. The hypothesis of the study was that there was no statistically significant difference between postoperative results and preoperatively planned values. The study showed that (1) the difference between the postoperative mechanical axis (mean 1.9° varus ± 1.2° SD) and the planned mechanical axis (mean 1.8° varus ± 1.2° SD) was not statistically significant; (2) the difference between the postoperative tibial slope (mean 5.2° ± 0.6° SD) and the planned tibial slope (mean 5.4° ± 0.6° SD) was statistically significant (p = 0.008); and (3) the postoperative component fit to bone in the coronal and sagittal planes was accurate in all cases; nevertheless, in one knee, all components were implanted one size smaller than preoperatively planned. Moreover, in two additional cases, one size thinner and one size thicker of the polyethylene insert were used. This study suggests that overall patient-specific instrumentation was highly accurate in reproducing postoperatively what the surgeon had planned preoperatively in terms of mechanical axis, tibial

  18. Acute changes in foot strike pattern and cadence affect running parameters associated with tibial stress fractures.

    PubMed

    Yong, Jennifer R; Silder, Amy; Montgomery, Kate L; Fredericson, Michael; Delp, Scott L

    2018-05-18

    Tibial stress fractures are a common and debilitating injury that occur in distance runners. Runners may be able to decrease tibial stress fracture risk by adopting a running pattern that reduces biomechanical parameters associated with a history of tibial stress fracture. The purpose of this study was to test the hypothesis that converting to a forefoot striking pattern or increasing cadence without focusing on changing foot strike type would reduce injury risk parameters in recreational runners. Running kinematics, ground reaction forces and tibial accelerations were recorded from seventeen healthy, habitual rearfoot striking runners while running in their natural running pattern and after two acute retraining conditions: (1) converting to forefoot striking without focusing on cadence and (2) increasing cadence without focusing on foot strike. We found that converting to forefoot striking decreased two risk factors for tibial stress fracture: average and peak loading rates. Increasing cadence decreased one risk factor: peak hip adduction angle. Our results demonstrate that acute adaptation to forefoot striking reduces different injury risk parameters than acute adaptation to increased cadence and suggest that both modifications may reduce the risk of tibial stress fractures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Is a synthetic augmentation in medial open wedge high tibial osteotomies superior to no augmentation in terms of bone-healing?

    PubMed

    Ferner, Felix; Dickschas, Joerg; Ostertag, Helmut; Poske, Ulrich; Schwitulla, Judith; Harrer, Joerg; Strecker, Wolf

    2016-01-01

    Medial open-wedge high tibial osteotomy (MOWHTO) is an established method to treat unicompartimental osteoarthritis of the knee joint. However, augmentation of the created tibial gap after osteotomy is controversially discussed. We performed a prospective investigation of 49 consecutive cases of MOWHTO at our department. Patients were divided into two groups: group A consisted of 19 patients while group B consisted of 30 patients. In group A, the augmentation of the opening gap after osteotomy was filled with a synthetic bone graft, whereas group B received no augmentation. As an indicator for bone healing we investigated the non-union rate in our study population and compared the non-union-rate between the two groups. The non-union rate was 28% in group A (five of 19 patients had to undergo revision) which received synthetic augmentation, while it was 3.3% in group B (one of 30 patients had to undergo revision) which received no augmentation. The difference between the groups was statistically significant (p-value 0.027). With regard to bone healing after MOWHTO, synthetic augmentation was not superior to no augmentation in terms of non-union rates after surgery. In fact, we registered a significantly higher rate of non-union after augmentation with synthetic bone graft. III. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Association of physical activity and physical performance with tibial cartilage volume and bone area in young adults.

    PubMed

    Antony, Benny; Venn, Alison; Cicuttini, Flavia; March, Lyn; Blizzard, Leigh; Dwyer, Terence; Cross, Marita; Jones, Graeme; Ding, Changhai

    2015-10-26

    Physical activity has been recommended to patients with knee osteoarthritis for improving their symptoms. However, it is still controversial if physical activity has effects on joint structures including cartilage volume. The aim of this study was to describe the associations between physical activity and performance measured 5 years prior and tibial cartilage volume and bone area in young adults. Subjects broadly representative of the Australian population (n = 328, aged 31-41 years, female 47.3 %) were selected from the Childhood Determinants of Adult Health study. They underwent T1-weighted fat-suppressed magnetic resonance imaging (MRI) scans of their knees. Tibial bone area and cartilage volume were measured from MRI. Physical activity (measured using long international physical activity questionnaire (IPAQ)) and performance measures (long jump, leg muscle strength, physical work capacity (PWC170)) were measured 5 years prior. In multivariable analyses, total physical activity (min/week) (β: 0.30 mm(3), 95 % CI: 0.13,0.47), vigorous (β: 0.54 mm(3), 95 % CI: 0.13,0.94), moderate (β: 0.34 mm(3), 95 % CI: 0.01,0.67), walking (β: 0.40 mm(3), 95 % CI: 0.07,0.72) and IPAQ category (β: 182.9 mm(3), 95 % CI: 51.8,314.0) were positively associated with total tibial cartilage volume but not tibial bone area. PWC170, long jump and leg muscle strength were positively and significantly associated with both total tibial cartilage volume and total tibial bone area; and the associations with tibial cartilage volume decreased in magnitude but remained significant for PWC170 and long jump after further adjustment for tibial bone area. While tibial bone area is affected only by physical performance, total tibial cartilage volume can be influenced by both physical activity and performance in younger adults. The clinical significance suggests a beneficial effect for cartilage but the bone area association was restricted to performance suggesting other factors

  1. The Impact of Imaging Modality on the Measurement of Coronal Plane Alignment After Total Knee Arthroplasty.

    PubMed

    Nam, Denis; Vajapey, Sravya; Nunley, Ryan M; Barrack, Robert L

    2016-10-01

    The optimal coronal alignment after total knee arthroplasty (TKA) has become an area of increased debate. Sources of variability among investigations include the radiographic technique used for both preoperative surgical planning and postoperative alignment assessments. This study's purpose was to assess the impact of the imaging modality used on the measurement of coronal plane alignment after TKA. A consecutive series of patients undergoing TKA using the same cruciate-retaining prosthesis were included for analysis. Postoperatively, all patients received both a rotationally controlled, scout computed tomography scan and a hip-knee-ankle (HKA) image using the EOS Imaging system (EOS Inc., Paris, France). Two, independent observers measured the HKA angle, and femoral and tibial component alignment from each image. After classifying overall and component alignment as neutral, varus, or valgus, 40.6% (65 of 160) of knees had a discordant alignment classification for HKA, 28.1% (45 of 160) for femoral component alignment, and 26.9% (43 of 160) for tibial component alignment between their computed tomography and EOS images. Overall, 24.4% (39 of 160) of patients had a HKA difference of ≥3° between the 2 images, whereas 18.8% (30 of 160) and 20.0% (32 of 160) of patients had a femoral and tibial component alignment difference of ≥2°, respectively. Significant differences are present when comparing 2 measurement techniques of mechanical alignment after TKA. The impact of imaging modality on postoperative assessments must be accounted for and be consistent when comparing the results of different investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Effect of cranial cruciate ligament deficiency, tibial plateau leveling osteotomy, and tibial tuberosity advancement on contact mechanics and alignment of the stifle in flexion.

    PubMed

    Kim, Stanley E; Pozzi, Antonio; Banks, Scott A; Conrad, Bryan P; Lewis, Daniel D

    2010-04-01

    To assess contact mechanics and 3-dimensional (3-D) joint alignment in cranial cruciate ligament (CCL)-deficient stifles before and after tibial plateau leveling osteotomy (TPLO) and tibial tuberosity advancement (TTA) with the stifle in 90 degrees of flexion. In vitro biomechanical study. Cadaveric pelvic limb pairs (n=8) from dogs weighing 28-35 kg. Contralateral limbs were assigned to receive TPLO or TTA. Digital pressure sensors were used to measure femorotibial contact area, peak and mean contact pressure, and peak pressure location with the limb under a load of 30% body weight and stifle flexion angle of 90 degrees . 3-D poses were obtained using a Microscribe digitizer. Specimens were tested under normal, CCL deficient, and treatment conditions. Significant disturbances in alignment were not observed after CCL transection, although medial contact area was 10% smaller than normal (P=.003). There were no significant differences in contact mechanics or alignment between normal and TTA conditions; TPLO induced 6 degrees varus angulation (P<.001), 26% decrease in lateral peak pressure (P=.027), and 18% increase in medial mean pressure (P=.008) when compared with normal. Cranial tibial subluxation is nominal in CCL-deficient stifles loaded in flexion. Stifle alignment and contact mechanics are not altered by TTA, whereas TPLO causes mild varus and a subsequent increase in medial compartment loading. Cranial tibial subluxation of CCL-deficient stifles may not occur during postures that load the stifle in flexion. The significance of minor changes in loading patterns after TPLO is unknown.

  3. [Surgical treatment of tibial nonunion after wounding by high velocity missile and external fixators: a case report].

    PubMed

    Golubović, Ivan; Vukašinović, Zoran; Stojiljković, Predrag; Golubović, Zoran; Stojiljković, Danilo; Radovanović, Zoran; Ilić, Nenad; Najman, Stevo; Višnjić, Aleksandar; Arsić, Stojanka

    2012-01-01

    The missiles of modern firearms can cause severe fractures of the extremity. High velocity missile fractures of the tibia are characterized by massive tissue destruction and primary contamination with polymorphic bacteria. Treatment of these fractures is often complicated by delayed healing, poor position healing, nonhealing and bone tissue infection. We present the management of tibial nonunion after wounding by high velocity missile and primary treatment by external fixation in a 25-year-old patient. The patient was primarily treated with external fixation and reconstructive operations of the soft tissue without union of the fracture. Seven months after injury we placed a compression-distraction external fixator type Mitkovic and started with compression and distraction in the fracture focus after osteotomy of the fibula and autospongioplasty. We recorded satisfactory fracture healing and good functional outcome. Contamination and devitalization of the soft-tissue envelope increase the risk of infection and nonunion in fractures after wounding by high velocity missile. The use of the compression-distraction external fixator type Mitkovic may be an effective method in nonunions of the tibia after this kind of injury.

  4. High contrast imaging through adaptive transmittance control in the focal plane

    NASA Astrophysics Data System (ADS)

    Dhadwal, Harbans S.; Rastegar, Jahangir; Feng, Dake

    2016-05-01

    High contrast imaging, in the presence of a bright background, is a challenging problem encountered in diverse applications ranging from the daily chore of driving into a sun-drenched scene to in vivo use of biomedical imaging in various types of keyhole surgeries. Imaging in the presence of bright sources saturates the vision system, resulting in loss of scene fidelity, corresponding to low image contrast and reduced resolution. The problem is exacerbated in retro-reflective imaging systems where the light sources illuminating the object are unavoidably strong, typically masking the object features. This manuscript presents a novel theoretical framework, based on nonlinear analysis and adaptive focal plane transmittance, to selectively remove object domain sources of background light from the image plane, resulting in local and global increases in image contrast. The background signal can either be of a global specular nature, giving rise to parallel illumination from the entire object surface or can be represented by a mosaic of randomly orientated, small specular surfaces. The latter is more representative of real world practical imaging systems. Thus, the background signal comprises of groups of oblique rays corresponding to distributions of the mosaic surfaces. Through the imaging system, light from group of like surfaces, converges to a localized spot in the focal plane of the lens and then diverges to cast a localized bright spot in the image plane. Thus, transmittance of a spatial light modulator, positioned in the focal plane, can be adaptively controlled to block a particular source of background light. Consequently, the image plane intensity is entirely due to the object features. Experimental image data is presented to verify the efficacy of the methodology.

  5. The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

    PubMed

    Shi, Xiaojun; Shen, Bin; Kang, Pengde; Yang, Jing; Zhou, Zongke; Pei, Fuxing

    2013-12-01

    To evaluate and quantify the effect of the tibial slope on the postoperative maximal knee flexion and stability in the posterior-stabilized total knee arthroplasty (TKA). Fifty-six patients (65 knees) who had undergone TKA with the posterior-stabilized prostheses were divided into the following 3 groups according to the measured tibial slopes: Group 1: ≤4°, Group 2: 4°-7° and Group 3: >7°. The preoperative range of the motion, the change in the posterior condylar offset, the elevation of the joint line, the postoperative tibiofemoral angle and the preoperative and postoperative Hospital for Special Surgery (HSS) scores were recorded. The tibial anteroposterior translation was measured using the Kneelax 3 Arthrometer at both the 30° and the 90° flexion angles. The mean values of the postoperative maximal knee flexion were 101° (SD 5), 106° (SD 5) and 113° (SD 9) in Groups 1, 2 and 3, respectively. A significant difference was found in the postoperative maximal flexion between the 3 groups (P < 0.001). However, no significant differences were found between the 3 groups in the postoperative HSS scores, the changes in the posterior condylar offset, the elevation of the joint line or the tibial anteroposterior translation at either the 30° or the 90° flexion angles. A 1° increase in the tibial slope resulted in a 1.8° flexion increment (r = 1.8, R (2) = 0.463, P < 0.001). An increase in the posterior tibial slope can significantly increase the postoperative maximal knee flexion. The tibial slope with an appropriate flexion and extension gap balance during the operation does not affect the joint stability.

  6. Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report.

    PubMed

    Ozdemir, Guzelali; Azboy, Ibrahim; Yilmaz, Baris

    2016-01-01

    Periprosthetic fractures around the knee after total knee arthroplasty can be seen in the femur, tibia and patella. The tibial fractures are rare cases. Our case with bilateral tibial stress fracture developed after total knee arthroplasty (TKA) is the first of its kind in the literature. 75-year-old male patient with bilateral knee osteoarthritis had not benefited from conservative treatment methods previously applied. Left TKA was applied. In the second month postoperatively, periprosthetic tibial fracture was identified and osteosynthesis was implemented with locked tibia proximal plate-screw. Bone union in 12 weeks was observed in his follow-ups. After 15 months of his first operation, TKA was applied to the right knee. Postoperatively in the second month, as in the first operation, periprosthetic tibial fracture was detected. Osteosynthesis with locking plate-screw was applied and union in 12 weeks was observed in his follow-up. He was seen mobilized independently and without support in the last control of the case made in the 24th month after the second operation. The number of TKA applications is expected to increase in the future. The incidence of periprosthetic fractures should also be expected to increase in these cases. Periprosthetic tibial fractures after TKA are rarely seen. The treatment of periprosthetic fractures around the knee after TKA can be difficult. In the case of persistent pain in the upper end of the tibia after the surgery, stress fracture should be considered. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Larger medial femoral to tibial condylar dimension may trigger posterior root tear of medial meniscus.

    PubMed

    Chung, Jun Young; Song, Hyung Keun; Jung, Myung Kuk; Oh, Hyeong Tak; Kim, Joon Ho; Yoon, Ji-Sang; Min, Byoung-Hyun

    2016-05-01

    The major meniscal functions are load bearing, load distribution, and shock absorption by increasing the tibiofemoral joint (TFJ) contact area and dissipating axial loads by conversion into hoop stresses. The increased hoop strain stretches the meniscus in outward direction towards radius, causing extrusion, which is associated with the root tear and resultant degenerative osteoarthritis. Since the larger contact area of medial TFJ may increase the hoop stresses, we hypothesized that the larger medial femoral to tibial condylar dimension would contribute to the development of medial meniscus posterior root tear (MMPRT). Thus, the purpose of the study was to assess the relationship between MMPRT and medial femoral to tibial condylar dimension. A case-control study was conducted to compare medial femoral to tibial condylar dimensions of patients with complete MMPRT (n = 59) with those of demography-matched controls (n = 59) during the period from 2010 to 2013. In each patient, MRIs were reviewed and several parameters were measured including articulation width of medial femoral condyle (MFC) at 0°, 30°, 60°, and 90°, medial tibial condyle (MTC) width, degree of meniscal extrusion, and medial femoral to tibial condylar width ratio (MFC/MTC) at 0°, 30°, 60°, and 90°, respectively. Demographic and radiographic data were assessed. A larger medial femoral to tibial condylar dimension was associated with MMPRT at 0° and 30° knee angles. Patients with MFC/MTC greater than 0.9 at 0° also showed about 2.5-fold increase in the chance of MMPRT. Those with meniscal extrusion greater than 3 mm also had about 17.1 times greater chance for the presence of MMPRT accordingly. A larger medial femoral to tibial condylar dimension may be considered as one of the regional contributors to the outbreak of MMPRT, and medial femoral to tibial condylar width ratio greater than 0.9 at 0° knee angle may be considered as a significant risk factor for MMPRT. III.

  8. Posterior tibial nerve stimulation vs parasacral transcutaneous neuromodulation for overactive bladder in children.

    PubMed

    Barroso, Ubirajara; Viterbo, Walter; Bittencourt, Joana; Farias, Tiago; Lordêlo, Patrícia

    2013-08-01

    Parasacral transcutaneous electrical nerve stimulation and posterior tibial nerve stimulation have emerged as effective methods to treat overactive bladder in children. However, to our knowledge no study has compared the 2 methods. We evaluated the results of parasacral transcutaneous electrical nerve stimulation and posterior tibial nerve stimulation in children with overactive bladder. We prospectively studied children with overactive bladder without dysfunctional voiding. Success of treatment was evaluated by visual analogue scale and dysfunctional voiding symptom score, and by level of improvement of each specific symptom. Parasacral transcutaneous electrical nerve stimulation was performed 3 times weekly and posterior tibial nerve stimulation was performed once weekly. A total of 22 consecutive patients were treated with posterior tibial nerve stimulation and 37 with parasacral transcutaneous electrical nerve stimulation. There was no difference between the 2 groups regarding demographic characteristics or types of symptoms. Concerning the evaluation by visual analogue scale, complete resolution of symptoms was seen in 70% of the group undergoing parasacral transcutaneous electrical nerve stimulation and in 9% of the group undergoing posterior tibial nerve stimulation (p = 0.02). When the groups were compared, there was no statistically significant difference (p = 0.55). The frequency of persistence of urgency and diurnal urinary incontinence was nearly double in the group undergoing posterior tibial nerve stimulation. However, this difference was not statistically significant. We found that parasacral transcutaneous electrical nerve stimulation is more effective in resolving overactive bladder symptoms, which matches parental perception. However, there were no statistically significant differences in the evaluation by dysfunctional voiding symptom score, or in complete resolution of urgency or diurnal incontinence. Copyright © 2013 American Urological

  9. An Improved Tibial Force Sensor to Compute Contact Forces and Contact Locations In Vitro After Total Knee Arthroplasty.

    PubMed

    Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2017-04-01

    Contact force imbalance and contact kinematics (i.e., motion of the contact location in each compartment during flexion) of the tibiofemoral joint are both important predictors of a patient's outcome following total knee arthroplasty (TKA). Previous tibial force sensors have limitations in that they either did not determine contact forces and contact locations independently in the medial and lateral compartments or only did so within restricted areas of the tibial insert, which prevented them from thoroughly evaluating contact force imbalance and contact kinematics in vitro. Accordingly, the primary objective of this study was to present the design and verification of an improved tibial force sensor which overcomes these limitations. The improved tibial force sensor consists of a modified tibial baseplate which houses independent medial and lateral arrays of three custom tension-compression transducers each. This sensor is interchangeable with a standard tibial component because it accommodates tibial articular surface inserts with a range of sizes and thicknesses. This sensor was verified by applying known loads at known locations over the entire surface of the tibial insert to determine the errors in the computed contact force and contact location in each compartment. The root-mean-square errors (RMSEs) in contact force are ≤ 6.1 N which is 1.4% of the 450 N full-scale output. The RMSEs in contact location are ≤ 1.6 mm. This improved tibial force sensor overcomes the limitations of the previous sensors and therefore should be useful for in vitro evaluation of new alignment goals, new surgical techniques, and new component designs in TKA.

  10. Ipsilateral intact fibula as a predictor of tibial plafond fracture pattern and severity.

    PubMed

    Luk, Pamela C; Charlton, Timothy P; Lee, Jackson; Thordarson, David B

    2013-10-01

    The objective of this study was to determine whether there is a difference in fracture pattern and severity of comminution between tibial plafond fractures with and without associated fibular fractures using computed tomography (CT). We hypothesized that the presence of an intact fibula was predictive of increased tibial plafond fracture severity. This was a case control, radiographic review performed at a single level I university trauma center. Between November 2007 and July 2011, 104 patients with 107 operatively treated tibial pilon fractures and preoperative CT scans were identified: 70 patients with 71 tibial plafond fractures had associated fibular fractures, and 34 patients with 36 tibial plafond fractures had intact fibulas. Four criteria were compared between the 2 groups: AO/OTA classification of distal tibia fractures, Topliss coronal and sagittal fracture pattern classification, plafond region of greatest comminution, and degree of proximal extension of fracture line. The intact fibula group had greater percentages of AO/OTA classification B2 type (5.5 vs 0, P = .046) and B3 type (52.8 vs 28.2, P = .013). Conversely, the percentage of AO/OTA classification C3 type was greater in the fractured fibula group (53.5 vs 30.6, P = .025). Evaluation using the Topliss sagittal and coronal classifications revealed no difference between the 2 groups (P = .226). Central and lateral regions of the plafond were the most common areas of comminution in fractured fibula pilons (32% and 31%, respectively). The lateral region of the plafond was the most common area of comminution in intact fibula pilon fractures (42%). There was no statistically significant difference (P = .71) in degree of proximal extension of fracture line between the 2 groups. Tibial plafond fractures with intact fibulas were more commonly associated with AO/OTA classification B-type patterns, whereas those with fractured fibulas were more commonly associated with C-type patterns. An intact fibula

  11. Comparison between Closing-Wedge and Opening-Wedge High Tibial Osteotomy in Patients with Medial Knee Osteoarthritis: A Systematic Review and Meta-analysis.

    PubMed

    Sun, Hao; Zhou, Lin; Li, Fengsheng; Duan, Jun

    2017-02-01

    Young active patients with medial knee osteoarthritis (OA) combined with varus leg alignment can be treated with high tibial osteotomy (HTO) to stop the progression of OA and avoid or postpone total knee arthroplasty (TKA). Closing-wedge osteotomy (CWO) and opening-wedge osteotomy (OWO) are the most commonly used osteotomy techniques. The purpose of this study was to compare the clinical and radiologic outcomes and complications between OWO and CWO. We retrospectively evaluated 23 studies including 17 clinical trials from published databases from their inception to May 2015. We evaluated the clinical outcomes including operation time, visual analog scale (VAS), maximal flexion, and hospital for special surgery knee (HSS) score. The radiologic outcomes included patellar height measured by posterior tibial slope angle, hip-knee-ankle (HKA) angle, femorotibial (FT) axis, and limb length. Complications recorded included the incidence of deep vein thrombosis (DVT), common peroneal nerve injury, opposite cortical fracture, etc. There were no differences in most of the clinical outcomes except the operation time. OWO increased the posterior slope angle and limb length, decreased the patellar height, and provided higher accuracy of correction. CWO led to a higher incidence of opposite cortical fracture. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Posterior tibial vein aneurysm presenting as tarsal tunnel syndrome.

    PubMed

    Ayad, Micheal; Whisenhunt, Anumeha; Hong, EnYaw; Heller, Josh; Salvatore, Dawn; Abai, Babak; DiMuzio, Paul J

    2015-06-01

    Tarsal tunnel syndrome is a compressive neuropathy of the posterior tibial nerve within the tarsal tunnel. Its etiology varies, including space occupying lesions, trauma, inflammation, anatomic deformity, iatrogenic injury, and idiopathic and systemic causes. Herein, we describe a 46-year-old man who presented with left foot pain. Work up revealed a venous aneurysm impinging on the posterior tibial nerve. Following resection of the aneurysm and lysis of the nerve, his symptoms were alleviated. Review of the literature reveals an association between venous disease and tarsal tunnel syndrome; however, this report represents the first case of venous aneurysm causing symptomatic compression of the nerve. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. A New Multiaxial High-Cycle Fatigue Criterion Based on the Critical Plane for Ductile and Brittle Materials

    NASA Astrophysics Data System (ADS)

    Wang, Cong; Shang, De-Guang; Wang, Xiao-Wei

    2015-02-01

    An improved high-cycle multiaxial fatigue criterion based on the critical plane was proposed in this paper. The critical plane was defined as the plane of maximum shear stress (MSS) in the proposed multiaxial fatigue criterion, which is different from the traditional critical plane based on the MSS amplitude. The proposed criterion was extended as a fatigue life prediction model that can be applicable for ductile and brittle materials. The fatigue life prediction model based on the proposed high-cycle multiaxial fatigue criterion was validated with experimental results obtained from the test of 7075-T651 aluminum alloy and some references.

  14. Gait retraining and incidence of medial tibial stress syndrome in army recruits.

    PubMed

    Sharma, Jagannath; Weston, Matthew; Batterham, Alan M; Spears, Iain R

    2014-09-01

    Gait retraining, comprising biofeedback and/or an exercise intervention, might reduce the risk of musculoskeletal conditions. The purpose was to examine the effect of a gait-retraining program on medial tibial stress syndrome incidence during a 26-wk basic military training regimen. A total of 450 British Army recruits volunteered. On the basis of a baseline plantar pressure variable (mean foot balance during the first 10% of stance), participants classified as at risk of developing medial tibial stress syndrome (n = 166) were randomly allocated to an intervention (n = 83) or control (n = 83) group. The intervention involved supervised gait retraining, including exercises to increase neuromuscular control and flexibility (three sessions per week) and biofeedback enabling internalization of the foot balance variable (one session per week). Both groups continued with the usual military training regimen. Diagnoses of medial tibial stress syndrome over the 26-wk regimen were made by physicians blinded to the group assignment. Data were modeled in a survival analysis using Cox regression, adjusting for baseline foot balance and time to peak heel rotation. The intervention was associated with a substantially reduced instantaneous relative risk of medial tibial stress syndrome versus control, with an adjusted HR of 0.25 (95% confidence interval, 0.05-0.53). The number needed to treat to observe one additional injury-free recruit in intervention versus control at 20 wk was 14 (11 to 23) participants. Baseline foot balance was a nonspecific predictor of injury, with an HR per 2 SD increment of 5.2 (1.6 to 53.6). The intervention was effective in reducing incidence of medial tibial stress syndrome in an at-risk military sample.

  15. Biomechanical analysis of posteromedial tibial plateau split fracture fixation.

    PubMed

    Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang

    2011-01-01

    The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Delayed presentation is no barrier to satisfactory outcome in the management of open tibial fractures.

    PubMed

    Ashford, Robert U; Mehta, Janak A; Cripps, Robin

    2004-04-01

    The management of open tibial fractures is a challenge to all orthopaedic trauma surgeons. The major goals are fracture union, uncomplicated soft tissue healing and return to pre-injury level of function. The geographical isolation and vastness of the Northern Territory of Australia complicates the management of these injuries by adding a significant delay to treatment. Forty-five patients sustained 48 open tibial fractures over the 30-month period of the study. Twelve received primary surgical treatment within 6h of injury but 33 were treated more than 6h after injury. The mean time to treatment in this latter group was 12h 15min (median 9h 45min, range 6-37h). The majority of injuries were high energy, with 23 patients having multiple injuries and 29 fractures (60%) being classified as AO C3 with 35 (73%) having Gustilo III soft tissue injuries. There was a mean time to union of 7.5 months and an overall complication rate of 42.2%. Thirteen patients (29%) required additional (late) surgical procedures subsequent to definitive fracture and soft tissue management. The zone of injury infection rate was 12.5%. The high incidence of open tibial fractures places a large financial burden on the state. However, despite the absence of a plastic surgical service and delays in presentation, satisfactory outcomes can be obtained by the application of the established surgical principles of thorough debridement, soft tissue management and fracture stabilisation.

  17. Section modulus is the optimum geometric predictor for stress fractures and medial tibial stress syndrome in both male and female athletes.

    PubMed

    Franklyn, Melanie; Oakes, Barry; Field, Bruce; Wells, Peter; Morgan, David

    2008-06-01

    Various tibial dimensions and geometric parameters have been linked to stress fractures in athletes and military recruits, but many mechanical parameters have still not been investigated. Sedentary people, athletes with medial tibial stress syndrome, and athletes with stress fractures have smaller tibial geometric dimensions and parameters than do uninjured athletes. Cohort study; Level of evidence, 3. Using a total of 88 subjects, male and female patients with either a tibial stress fracture or medial tibial stress syndrome were compared with both uninjured aerobically active controls and uninjured sedentary controls. Tibial scout radiographs and cross-sectional computed tomography images of all subjects were scanned at the junction of the midthird and distal third of the tibia. Tibial dimensions were measured directly from the films; other parameters were calculated numerically. Uninjured exercising men have a greater tibial cortical cross-sectional area than do their sedentary and injured counterparts, resulting in a greater value of some other cross-sectional geometric parameters, particularly the section modulus. However, for women, the cross-sectional areas are either not different or only marginally different, and there are few tibial dimensions or geometric parameters that distinguish the uninjured exercisers from the sedentary and injured subjects. In women, the main difference between the groups was the distribution of cortical bone about the centroid as a result of the different values of section modulus. Last, medial tibial stress syndrome subjects had smaller tibial cross-sectional dimensions than did their uninjured exercising counterparts, suggesting that medial tibial stress syndrome is not just a soft-tissue injury but also a bony injury. The results show that in men, the cross-sectional area and the section modulus are the key parameters in the tibia to distinguish exercise and injury status, whereas for women, it is the section modulus only.

  18. Tibial anatomy in normal small breed dogs including anisometry of various extracapsular stabilizing suture attachment sites.

    PubMed

    Witte, P G

    2015-01-01

    To investigate proximal tibial anatomy and its influence on anisometry of extracapsular stabilizing sutures in small dog breeds. Mediolateral radiographs of the femora, stifles, and tibiae of 12 small breed dogs were acquired with the stifles positioned at various angles. Measurements taken included tibial plateau angle (TPA), diaphyseal: proximal tibial angle (DPA), patellar tendon angle (PTA), Z-angle, relative tibial tuberosity width (rTTW), and the distance between six combinations of two femoral and three tibial extra-capsular stabilizing suture (ECS) attachment sites. Theoretical strain through stifle range-of-motion was recorded. The TPA (32° ± 5.8°), DPA (10.2° ± 7.3°), PTA (103.7° ± 6.2°), and Z-angle (70.4° ± 9.0°) were positively correlated with one another (R >0.7), but none were correlated with rTTW (0.93 ± 0.10). The F2-T1 combination of ECS attachment sites had lowest strain for nine stifles. The shortest attachment site separation was at a stifle flexion of 50° for nine stifles. Proximal tibial anatomy measurements could not predict optimal attachment site combination, optimal stifle angle for suture placement, or ECS strain. There is individual variation in the optimal attachment site combination and stifle angle for suture placement, which may influence consistency of outcomes with ECS.

  19. Foot and ankle kinematics in patients with posterior tibial tendon dysfunction.

    PubMed

    Ness, Mary Ellen; Long, Jason; Marks, Richard; Harris, Gerald

    2008-02-01

    The purpose of this study is to provide a quantitative characterization of gait in patients with posterior tibial tendon dysfunction (PTTD), including temporal-spatial and kinematic parameters, and to compare these results to those of a Normal population. Our hypothesis was that segmental foot kinematics were significantly different in multiple segments across multiple planes. A 15 camera motion analysis system and weight-bearing radiographs were employed to evaluate 3D foot and ankle motion in a population of 34 patients with PTTD (30 females, 4 males) and 25 normal subjects (12 females, 13 males). The four-segment Milwaukee Foot Model (MFM) with radiographic indexing was used to analyze foot and ankle motion and provided kinematic data in the sagittal, coronal and transverse planes as well as temporal-spatial information. The temporal-spatial parameters revealed statistically significant deviations in all four metrics for the PTTD population. Stride length, cadence and walking speed were all significantly diminished, while stance duration was significantly prolonged (p<0.0125). Significant kinematic differences were noted between the groups (p<0.002), including: (1) diminished dorsiflexion and increased eversion of the hindfoot; (2) decreased plantarflexion of the forefoot, as well as abduction shift and loss of the varus thrust in the forefoot; and (3) decreased range of motion (ROM) with diminished dorsiflexion of the hallux. The study provides an impetus for improved orthotic and bracing designs to aid in the care of distal foot segments during the treatment of PTTD. It also provides the basis for future evaluation of surgical efficacy. The course of this investigation may ultimately lead to improved treatment planning methods, including orthotic and operative interventions.

  20. ACL Roof Impingement Revisited: Does the Independent Femoral Drilling Technique Avoid Roof Impingement With Anteriorly Placed Tibial Tunnels?

    PubMed

    Tanksley, John A; Werner, Brian C; Conte, Evan J; Lustenberger, David P; Burrus, M Tyrrell; Brockmeier, Stephen F; Gwathmey, F Winston; Miller, Mark D

    2017-05-01

    Anatomic femoral tunnel placement for single-bundle anterior cruciate ligament (ACL) reconstruction is now well accepted. The ideal location for the tibial tunnel has not been studied extensively, although some biomechanical and clinical studies suggest that placement of the tibial tunnel in the anterior part of the ACL tibial attachment site may be desirable. However, the concern for intercondylar roof impingement has tempered enthusiasm for anterior tibial tunnel placement. To compare the potential for intercondylar roof impingement of ACL grafts with anteriorly positioned tibial tunnels after either transtibial (TT) or independent femoral (IF) tunnel drilling. Controlled laboratory study. Twelve fresh-frozen cadaver knees were randomized to either a TT or IF drilling technique. Tibial guide pins were drilled in the anterior third of the native ACL tibial attachment site after debridement. All efforts were made to drill the femoral tunnel anatomically in the center of the attachment site, and the surrogate ACL graft was visualized using 3-dimensional computed tomography. Reformatting was used to evaluate for roof impingement. Tunnel dimensions, knee flexion angles, and intra-articular sagittal graft angles were also measured. The Impingement Review Index (IRI) was used to evaluate for graft impingement. Two grafts (2/6, 33.3%) in the TT group impinged upon the intercondylar roof and demonstrated angular deformity (IRI type 1). No grafts in the IF group impinged, although 2 of 6 (66.7%) IF grafts touched the roof without deformation (IRI type 2). The presence or absence of impingement was not statistically significant. The mean sagittal tibial tunnel guide pin position prior to drilling was 27.6% of the sagittal diameter of the tibia (range, 22%-33.9%). However, computed tomography performed postdrilling detected substantial posterior enlargement in 2 TT specimens. A significant difference in the sagittal graft angle was noted between the 2 groups. TT grafts were

  1. Comparison of Clinical Results and Injury Risk of Posterior Tibial Cortex Between Attune and Press Fit Condylar Sigma Knee Systems.

    PubMed

    Song, Sang Jun; Park, Cheol Hee; Liang, Hu; Kang, Se Gu; Park, Jong Jun; Bae, Dae Kyung

    2018-02-01

    We compared clinical and radiographic results after total knee arthroplasty (TKA) using Attune and Press Fit Condylar Sigma, and investigated whether use of the current prosthesis increased injury risk to the tibial cortex in Asian patients. We also assessed whether a preoperative posterior tibial slope angle (PSA) is associated with the injury when using the current prosthesis. The 300 TKAs with Attune (group A) were compared to the 300 TKAs with Press Fit Condylar Sigma (group B). Demographics were not different, except follow-up periods (24.8 vs 33.3 months, P < .001). The Western Ontario and McMaster Universities Index and range of motion were compared. A minimum distance between tibial component stem and posterior tibial cortex (mDSC) was compared. The correlation between preoperative PSA and mDSC was analyzed in group A. The postoperative Western Ontario and McMaster Universities Index and range of motion of group A were better than those of group B (17.7 vs 18.8, P = .004; 131.4° vs 129.0°, P = .008). The mDSC was shorter in group A (6.3 vs 7.0 mm, P < .001), which made up a higher proportion of the high-risk group for posterior tibial cortical injury with an mDSC of <4 mm (20.0% vs 10.7%, P = .002). A negative correlation was found between the preoperative PSA and mDSC in group A (r = -0.205, P < .001). The TKA using the current prosthesis provided more satisfactory results than the TKA using the previous prosthesis. However, the injury risk to the posterior tibial cortex increased in the knees with a large PSA when using the current prosthesis for Asian patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. [The geometry of the keel determines the behaviour of the tibial tray against torsional forces in total knee replacement].

    PubMed

    García David, S; Cortijo Martínez, J A; Navarro Bermúdez, I; Maculé, F; Hinarejos, P; Puig-Verdié, L; Monllau, J C; Hernández Hermoso, J A

    2014-01-01

    The keel design of the tibial tray is essential for the transmission of the majority of the forces to the peripheral bone structures, which have better mechanical proprieties, thus reducing the risk of loosening. The aim of the present study was to compare the behaviour of different tibial tray designs submitted to torsional forces. Four different tibial components were modelled. The 3-D reconstruction was made using the Mimics software. The solid elements were generated by SolidWorks. The finite elements study was done by Unigraphics. A torsional force of 6 Nm. applied to the lateral aspects of each tibial tray was simulated. The GENUTECH® tibial tray, with peripheral trabecular bone support, showed a lower displacement and less transmitted tensions under torsional forces. The results suggest that a tibial tray with more peripheral support behaves mechanically better than the other studied designs. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  3. Does lateral versus medial exposure influence total knee tibial component final external rotation? A CT based study.

    PubMed

    Passeron, D; Gaudot, F; Boisrenoult, P; Fallet, L; Beaufils, P

    2009-10-01

    A previous study demonstrated that performing a total knee arthroplasty through a lateral approach including anterior tibial tuberosity (ATT) osteotomy (refixed in its original position) presented numerous advantages: correcting the preoperative patella lateral tilt and improving postoperative patella tracking. We hypothesized that these improvements in patella centering were, at least in part, due to an increased external rotation of the tibial component. Postoperative scannographic studies were, therefore, undertaken to measure tibial component rotation and analyze the results according the medial and lateral exposure used. Rotational positioning of the tibial component is influenced by the lateral or medial approach selected at surgery. Forty-five CAT scans, performed according to the protocol criteria of the French Hip and Knee Society (SFHG), were studied 3 months postoperatively: 15 knees operated through the lateral approach and 30 knees operated through a standard medial approach. The total knee utilized in all these cases was a posteriorly stabilized, fixed-bearing, design. We measured first the angle formed between the perpendicular to the transverse axis of the tibial component and the axis joining the ATT to the center of the knee; second we also measured the coronal distance between the center of the component and the anterior tibial tuberosity (ATT). In the group using the medial approach, the lateral position of the ATT was 7 + or - 3mm with a rotation angle of 18 degrees . In the group using the lateral approach these measurements were respectively 1 + or - 4mm and 2 degrees (p<0.0001). External rotation of the tibial component is substantially increased by the lateral approach compared to the medial approach. Better exposure of the lateral tibial plateau is probably responsible of this difference. This increased external rotation improves postoperative patella tracking. Prospective; comparative; non-randomized study; level 3. 2009 Elsevier Masson

  4. Reconstruction of bilateral tibial aplasia and split hand-foot syndrome in a father and daughter.

    PubMed

    Al Kaissi, Ali; Ganger, Rudolf; Klaushofer, Klaus; Grill, Franz

    2014-01-01

    Tibial aplasia is of heterogeneous aetiology, the majority of reports are sporadic. We describe the reconstruction procedures in two subjects - a daughter and father manifested autosomal dominant (AD) inheritance of the bilateral tibial aplasia and split hand-foot syndrome. Reconstruction of these patients required multiple surgical procedures and orthoprosthesis was mandatory. The main goal of treatment was to achieve walking. Stabilization of the ankle joint by fibular-talar-chondrodesis on both sides, followed by bilateral Brown-procedure at the knee joint level has been applied accordingly. The outcome was with improved function of the deformed limbs and walking was achieved with simultaneous designation of orthotic fitting. This is the first study encompassing the diagnosis and management of a father and daughter with bilateral tibial aplasia associated with variable split hand/foot deformity without foot ablation. Our patients showed the typical AD pattern of inheritance of split-hand/foot and tibial aplasia.

  5. Fractography and oxidative analysis of gamma inert sterilized posterior-stabilized tibial insert post fractures: report of two cases.

    PubMed

    Ansari, Farzana; Chang, Jennifer; Huddleston, James; Van Citters, Douglas; Ries, Michael; Pruitt, Lisa

    2013-12-01

    Highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) has shown success in reducing wear in hip arthroplasty but there remains skepticism about its use in Total Knee Replacement (TKR) inserts that are known to experience fatigue loading and higher local cyclic contact stresses. Two Legacy Posterior-Stabilized (LPS) Zimmer NexGen tibial implants sterilized by gamma irradiation in an inert environment with posts that fractured in vivo were analyzed. Failure mechanisms were determined using optical and scanning electron microscopy along with oxidative analysis via Fourier Transform Infra-Red (FTIR) spectroscopy. Micrographs of one retrieval revealed fatigue crack initiation on opposite sides of the post and quasi-brittle micromechanisms of crack propagation. FTIR of this retrieval revealed no oxidation. The fracture surface image of the second retrieval indicated a brittle fracture process and FTIR revealed oxidation in the explant. These two cases suggest that crosslinking of UHMWPE as a manufacturing process or sterilization method in conjunction with designs that incorporate high stress concentrations, such as the tibial post, may reduce material strength. Moreover, free radicals generated from ionizing radiation can render the polymer susceptible to oxidative embrittlement. Our findings suggest that tibial post fractures may be the results of in vivo oxidation and low level crosslinking. These and previous reports of fractured crosslinked UHMWPE devices implores caution when used with high stress concentrations, particularly when considering the potential for in vivo oxidation in TKR. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Return to Sport After Tibial Shaft Fractures

    PubMed Central

    Robertson, Greg A. J.; Wood, Alexander M.

    2015-01-01

    Context: Acute tibial shaft fractures represent one of the most severe injuries in sports. Return rates and return-to-sport times after these injuries are limited, particularly with regard to the outcomes of different treatment methods. Objective: To determine the current evidence for the treatment of and return to sport after tibial shaft fractures. Data Sources: OVID/MEDLINE (PubMed), EMBASE, CINAHL, Cochrane Collaboration Database, Web of Science, PEDro, SPORTDiscus, Scopus, and Google Scholar were all searched for articles published from 1988 to 2014. Study Selection: Inclusion criteria comprised studies of level 1 to 4 evidence, written in the English language, that reported on the management and outcome of tibial shaft fractures and included data on either return-to-sport rate or time. Studies that failed to report on sporting outcomes, those of level 5 evidence, and those in non–English language were excluded. Study Design: Systematic review. Level of Evidence: Level 4. Data Extraction: The search used combinations of the terms tibial, tibia, acute, fracture, athletes, sports, nonoperative, conservative, operative, and return to sport. Two authors independently reviewed the selected articles and created separate data sets, which were subsequently combined for final analysis. Results: A total of 16 studies (10 retrospective, 3 prospective, 3 randomized controlled trials) were included (n = 889 patients). Seventy-six percent (672/889) of the patients were men, with a mean age of 27.7 years. Surgical management was assessed in 14 studies, and nonsurgical management was assessed in 8 studies. Return to sport ranged from 12 to 54 weeks after surgical intervention and from 28 to 182 weeks after nonsurgical management (mean difference, 69.5 weeks; 95% CI, –83.36 to −55.64; P < 0.01). Fractures treated surgically had a return-to-sport rate of 92%, whereas those treated nonsurgically had a return rate of 67% (risk ratio, 1.37; 95% CI, 1.20 to 1.57; P < 0

  7. Study of the anatomy of the tibial nerve and its branches in the distal medial leg.

    PubMed

    Torres, André Leal Gonçalves; Ferreira, Marcus Castro

    2012-01-01

    Determine, through dissection in fresh cadavers, the topographic anatomy of the tibial nerve and its branches at the ankle, in relation to the tarsal tunnel. Bilateral dissections were performed on 26 fresh cadavers and the locations of the tibial nerve bifurcation and its branches were measured in millimeters. For the calcaneal branches, the amount and their respective nerves of origin were also analyzed. The tibial nerve bifurcation occurred under the tunnel in 88% of the cases and proximally in 12%. As for the calcaneal branches, the medial presented with one (58%), two (34%) and three (8%) branches, with the most common source occurring in the tibial nerve (90%) and the lower with a single branch per leg and lateral plantar nerve as the most common origin (70%). Level of Evidence, V Expert opinion .

  8. Fast 3D registration of multimodality tibial images with significant structural mismatch

    NASA Astrophysics Data System (ADS)

    Rajapakse, C. S.; Wald, M. J.; Magland, J.; Zhang, X. H.; Liu, X. S.; Guo, X. E.; Wehrli, F. W.

    2009-02-01

    Recently, micro-magnetic resonance imaging (μMRI) in conjunction with micro-finite element analysis has shown great potential in estimating mechanical properties - stiffness and elastic moduli - of bone in patients at risk of osteoporosis. Due to limited spatial resolution and signal-to-noise ratio achievable in vivo, the validity of estimated properties is often established by comparison to those derived from high-resolution micro-CT (μCT) images of cadaveric specimens. For accurate comparison of mechanical parameters derived from μMR and μCT images, analyzed 3D volumes have to be closely matched. The alignment of the micro structure (and the cortex) is often hampered by the fundamental differences of μMR and μCT images and variations in marrow content and cortical bone thickness. Here we present an intensity cross-correlation based registration algorithm coupled with segmentation for registering 3D tibial specimen images acquired by μMRI and μCT in the context of finite-element modeling to assess the bone's mechanical constants. The algorithm first generates three translational and three rotational parameters required to align segmented μMR and CT images from sub regions with high micro-structural similarities. These transformation parameters are then used to register the grayscale μMR and μCT images, which include both the cortex and trabecular bone. The intensity crosscorrelation maximization based registration algorithm described here is suitable for 3D rigid-body image registration applications where through-plane rotations are known to be relatively small. The close alignment of the resulting images is demonstrated quantitatively based on a voxel-overlap measure and qualitatively using visual inspection of the micro structure.

  9. The effects of sectioning the spring ligament on rearfoot stability and posterior tibial tendon efficiency.

    PubMed

    Jennings, Meagan M; Christensen, Jeffery C

    2008-01-01

    Posterior tibial tendon insufficiency has been implicated as a cause of adult acquired flatfoot. Multiple theories are debated as to whether or not a flatfoot deformity develops secondary to insufficiency of the posterior tibial tendon or of the ligamentous structures such as the spring ligament complex. This cadaveric study was undertaken in an attempt to determine the effect that sectioning the spring ligament complex has on foot stability, and whether engagement of the posterior tibial tendon would be able to compensate for the loss of the spring ligament complex. A 3-dimensional kinematic system and a custom-loading frame were used to quantify rotation about the talus, navicular, and calcaneus in 5 cadaveric specimens, before and after sectioning the spring ligament complex, while incremental tension was applied to the posterior tibial tendon. This study demonstrated that sectioning the spring ligament complex created instability in the foot for which the posterior tibial tendon was unable to compensate. Sectioning the spring ligament complex also produced significant changes in talar, navicular, and calcaneal rotations. During simulated midstance, the navicular plantarflexed, adducted, and everted; the talar head plantarflexed, adducted, and inverted; and the calcaneus plantarflexed, abducted, and everted, after sectioning the spring ligament complex. The results of this study indicate that the spring ligament complex is the major stabilizer of the arch during midstance and that the posterior tibial tendon is incapable of fully accommodating for its insufficiency, suggesting that the spring ligament complex should be evaluated and, if indicated, repaired in flatfoot reconstruction. 5.

  10. Survivorship comparison of all-polyethylene and metal-backed tibial components in cruciate-substituting total knee arthroplasty--Chinese experience.

    PubMed

    Shen, Bin; Yang, Jing; Zhou, Zongke; Kang, Pengde; Wang, Liao; Pei, Fuxing

    2009-10-01

    Considering its cost saving, the all-polyethylene tibial component is of potential interest in developing countries like China. But to our knowledge, a survivorship comparison of all-polyethylene and metal-backed tibial components in posterior cruciate ligament-substituting total knee arthroplasty (PS-TKA) has not been studied in China previously. Using survivorship analysis, we have studied the midterm outcome of 34 cemented PS-TKA using an all-polyethylene tibial component and of 34 cemented PS-TKA using a metal-backed tibial component which has an identical articular surface with all-polyethylene tibial components. All operations were performed by the same group of surgeons; 58 patients underwent a unilateral operation and five patients a bilateral operation. These patients had a mean follow-up of 5.9 years (range: 5-7 years); three patients were lost to follow-up and one was revised for infection. No significant difference between the two groups was reported regarding HSS scores, ROM, clinical and radiographic parameters measured and survival rates. Although the Asian lifestyle includes more squatting and bending of the knee, the results of this series of TKA using all-polyethylene tibial components in Chinese people are comparable to the satisfactory results of other reported all-polyethylene series whose patients are mainly Western people. Considering its cost saving and excellent clinical result, the all-polyethylene tibial component is of potential interest in developing countries.

  11. A novel approach: high resolution inspection with wafer plane defect detection

    NASA Astrophysics Data System (ADS)

    Hess, Carl; Wihl, Mark; Shi, Rui-fang; Xiong, Yalin; Pang, Song

    2008-05-01

    High Resolution reticle inspection is well-established as a proven, effective, and efficient means of detecting yield-limiting mask defects as well as defects which are not immediately yield-limiting yet can enable manufacturing process improvements. Historically, RAPID products have enabled detection of both classes of these defects. The newly-developed Wafer Plane Inspection (WPI) detector technology meets the needs of some advanced mask manufacturers to identify the lithographically-significant defects while ignoring the other non-lithographically-significant defects. Wafer Plane Inspection accomplishes this goal by performing defect detection based on a modeled image of how the mask features would actually print in the photoresist. This has the effect of reducing sensitivity to non-printing defects while enabling higher sensitivity focused in high MEEF areas where small reticle defects still yield significant printing defects on wafers. WPI is a new inspection mode that has been developed by KLA-Tencor and is currently under test with multiple customers. It employs the same transmitted and reflected-light high-resolution images as the industry-standard high-resolution inspections, but with much more sophisticated processing involved. A rigorous mask pattern recovery algorithm is used to convert the transmitted and reflected light images into a modeled representation of the reticle. Lithographic modeling of the scanner is then used to generate an aerial image of the mask. This is followed by resist modeling to determine the exposure of the photoresist. The defect detectors are then applied on this photoresist plane so that only printing defects are detected. Note that no hardware modifications to the inspection system are required to enable this detector. The same tool will be able to perform both our standard High Resolution inspections and the Wafer Plane Inspection detector. This approach has several important features. The ability to ignore non

  12. Effect of tibial plateau leveling osteotomy on femorotibial contact mechanics and stifle kinematics.

    PubMed

    Kim, Stanley E; Pozzi, Antonio; Banks, Scott A; Conrad, Bryan P; Lewis, Daniel D

    2009-01-01

    To evaluate the effects of tibial plateau leveling osteotomy (TPLO) on femorotibial contact mechanics and 3-dimensional (3D) kinematics in cranial cruciate ligament (CrCL)-deficient stifles of dogs. In vitro biomechanical study. Unpaired pelvic limbs from 8 dogs, weighing 28-35 kg. Digital pressure sensors placed subjacent to the menisci were used to measure femorotibial contact force, contact area, peak and mean contact pressure, and peak pressure location with the limb under an axial load of 30% body weight and a stifle angle of 135 degrees. Three-dimensional static poses of the stifle were obtained using a Microscribe digitizing arm. Each specimen was tested under normal, CrCL-deficient, and TPLO-treated conditions. Repeated measures analysis of variance with a Tukey post hoc test (P<.05) was used for statistical comparison. Significant disturbances to all measured contact mechanical variables were evident after CrCL transection, which corresponded to marked cranial tibial subluxation and increased internal tibial rotation in the CrCL-deficient stifle. No significant differences in 3D femorotibial alignment were observed between normal and TPLO-treated stifles; however, femorotibial contact area remained significantly smaller and peak contact pressures in both medial and lateral stifle compartments were positioned more caudally on the tibial plateau, when compared with normal. Whereas TPLO eliminates craniocaudal stifle instability during simulated weight bearing, the procedure fails to concurrently restore femorotibial contact mechanics to normal. Progression of stifle osteoarthritis in dogs treated with TPLO may be partly the result of abnormal stifle contact mechanics induced by altering the orientation of the proximal tibial articulating surface.

  13. Empty substrate integrated waveguide technology for E plane high-frequency and high-performance circuits

    NASA Astrophysics Data System (ADS)

    Belenguer, Angel; Cano, Juan Luis; Esteban, Héctor; Artal, Eduardo; Boria, Vicente E.

    2017-01-01

    Substrate integrated circuits (SIC) have attracted much attention in the last years because of their great potential of low cost, easy manufacturing, integration in a circuit board, and higher-quality factor than planar circuits. A first suite of SIC where the waves propagate through dielectric have been first developed, based on the well-known substrate integrated waveguide (SIW) and related technological implementations. One step further has been made with a new suite of empty substrate integrated waveguides, where the waves propagate through air, thus reducing the associated losses. This is the case of the empty substrate integrated waveguide (ESIW) or the air-filled substrate integrated waveguide (air-filled SIW). However, all these SIC are H plane structures, so classical H plane solutions in rectangular waveguides have already been mapped to most of these new SIC. In this paper a novel E plane empty substrate integrated waveguide (ESIW-E) is presented. This structure allows to easily map classical E plane solutions in rectangular waveguide to this new substrate integrated solution. It is similar to the ESIW, although more layers are needed to build the structure. A wideband transition (covering the frequency range between 33 GHz and 50 GHz) from microstrip to ESIW-E is designed and manufactured. Measurements are successfully compared with simulation, proving the validity of this new SIC. A broadband high-frequency phase shifter (for operation from 35 GHz to 47 GHz) is successfully implemented in ESIW-E, thus proving the good performance of this new SIC in a practical application.

  14. Tibial plateau fracture after primary anatomic double-bundle anterior cruciate ligament reconstruction: a case report.

    PubMed

    Gobbi, Alberto; Mahajan, Vivek; Karnatzikos, Georgios

    2011-05-01

    Tibial plateau fracture after primary anatomic double-bundle anterior cruciate ligament (ACL) reconstruction is rare. To our knowledge, this is the first case report of a tibial plateau fracture after primary anatomic double-bundle ACL reconstruction. In our patient the tibial plateau fracture occurred after a torsional injury to the involved extremity. The fracture occurred 4.5 years after the ACL reconstruction. The fracture was intra-articular Schatzker type IV and had a significant displacement. The patient was treated operatively by open reduction-internal fixation. He recovered well. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Negative pressure wound therapy for Gustilo Anderson grade IIIb open tibial fractures.

    PubMed

    Park, Chul Hyun; Shon, Oog Jin; Kim, Gi Beom

    2016-09-01

    Traditionally, Gustilo Anderson grade IIIb open tibial fractures have been treated by initial wide wound debridement, stabilization of fracture with external fixation, and delayed wound closure. The purpose of this study is to evaluate the clinical and radiological results of staged treatment using negative pressure wound therapy (NPWT) for Gustilo Anderson grade IIIb open tibial fractures. 15 patients with Gustilo Anderson grade IIIb open tibial fractures, treated using staged protocol by a single surgeon between January 2007 and December 2011 were reviewed in this retrospective study. The clinical results were assessed using a Puno scoring system for severe open fractures of the tibia at the last followup. The range of motion (ROM) of the knee and ankle joints and postoperative complication were evaluated at the last followup. The radiographic results were assessed using time to bone union, coronal and sagittal angulations and a shortening at the last followup. The mean score of Puno scoring system was 87.4 (range 67-94). The mean ROM of the knee and ankle joints was 121.3° (range 90°-130°) and 37.7° (range 15°-50°), respectively. Bone union developed in all patients and the mean time to union was 25.3 weeks (range 16-42 weeks). The mean coronal angulation was 2.1° (range 0-4°) and sagittal was 2.7° (range 1-4°). The mean shortening was 4.1 mm (range 0-8 mm). Three patients had partial flap necrosis and 1 patient had total flap necrosis. There was no superficial and deep wound infection. Staged treatment using NPWT decreased the risks of infection and requirement of flap surgeries in Gustilo Anderson grade IIIb open tibial fractures. Therefore, staged treatment using NPWT could be a useful treatment option for Gustilo Anderson grade IIIb open tibial fractures.

  16. Quantitative Comparison of the Microscopic Anatomy of the Human ACL Femoral and Tibial Entheses

    PubMed Central

    Beaulieu, Mélanie L.; Carey, Grace E.; Schlecht, Stephen H.; Wojtys, Edward M.; Ashton-Miller, James A.

    2015-01-01

    The femoral enthesis of the human anterior cruciate ligament (ACL) is known to be more susceptible to injury than the tibial enthesis. To determine whether anatomic differences might help explain this difference, we quantified the microscopic appearance of both entheses in 15 unembalmed knee specimens using light microscopy, toluidine blue stain and image analysis. The amount of calcified fibrocartilage and uncalcified fibrocartilage, and the ligament entheseal attachment angle were then compared between the femoral and tibial entheses via linear mixed-effects models. The results showed marked differences in anatomy between the two entheses. The femoral enthesis exhibited a 3.9-fold more acute ligament attachment angle than the tibial enthesis (p < 0.001), a 43% greater calcified fibrocartilage tissue area (p < 0.001), and a 226% greater uncalcified fibrocartilage depth (p < 0.001), with the latter differences being particularly pronounced in the central region. We conclude that the ACL femoral enthesis has more fibrocartilage and a more acute ligament attachment angle than the tibial enthesis, which provides insight into why it is more vulnerable to failure. PMID:26134706

  17. Discrepancy of alignment in different weight bearing conditions before and after high tibial osteotomy.

    PubMed

    Wang, Joon Ho; Shin, Jung Min; Kim, Hyun Ho; Kang, Seung-Hoon; Lee, Byung Hoon

    2017-01-01

    To evaluate the differences in the amount of varus malalignment and valgus (over) correction in relation to three different weight bearing conditions from whole leg AP radiographs (single-limb (SL) stance, double-limb (DL) stance, supine position (S)) before and after high tibial osteotomy (HTO), and to evaluate which alignment parameters affect the changes for patients in three different weight bearing conditions. A total of 40 consecutive patients (43 knees) with varus osteoarthritis underwent navigation assisted open wedge HTO. Mechanical axis angle (MA) was measured before and after surgery from hip-to-ankle radiographs taken with patients in three different weight bearing conditions. To find significant factors that affect the alignment differences, several variables including patient demographics, soft tissue laxity, pelvic obliquity, and ground mechanical axis deviation of tibia (calculated by the angle between two lines, tibial anatomical axis and weight-bearing line) were evaluated. Pre-operatively, mean MA measured on SL stance radiographs was significantly more varus than on DL stance (10.1° ± 2.4° and 8.0° ± 2.6°, respectively, p < 0.001), which was significantly more varus than on supine position (6.6° ± 2.6°, p < 0.001). Meanwhile, in patients with post-operatively valgus corrected knee, MA did not show the same pattern of change as with pre-operative varus knee. Mean MA measured on DL stance radiographs was more valgus than in supine position (-3.0 o  ± 2.4 o and -2.6 o  ± 3.1 o , p = 0.455), while mean MA on SL stance radiographs (-2.0 o  ± 2.1 o ) was significantly less valgus than on DL stance (p = 0.002). The ground mechanical axis deviation of tibia showed a significant correlation with MA difference between SL and DL stance radiographs before (β = -0.341, p = 0.045) and after surgery (β = -0.536, p = 0.001). In pre-operative varus knee, the mean MA on SL stance was changed to

  18. [Combined closing-wedge high tibial osteotomy with arthroscopy for varus knee and medial compartment osteoarthritis: clinical results at a minimum follow-up for five years].

    PubMed

    Liu, Jin-Song; Li, Zhi-Yao

    2013-09-01

    To study the results of closing-wedge high tibial osteotomy and arthroscopy for the treatment of medial compartment osteoarthritis of the knee. From October 2005 to June 2007, 25 patients met with our inclusion criteria. All the patients with medial compartment knee osteoarthritis were treated with arthroscopy and closing-wedge high tibial osteotomy. There were 11 males and 14 females,with a mean age of 53 years old. The pre-operative HSS knee score was 67.6 +/- 2.8, FTA was (185.54 +/- 1.11) degrees, and aLPTA was (96.54 +/- 0.52) degrees in average. The patients were followed up and evaluated according to HSS knee score. The efficacy of the osteotomy was evaluated by FTA and aLPTA. All surgeries were successful without serious complication. All the patients were followed up, and the duration ranged from 5 to 7 years. The HSS was 85.5 +/- 3.7 at the 1st year and 80.3 +/- 5.4 at the latest follow-up. There was significant difference between every two scores of before operation and the two after operation (t = -33.135, P = 0.000; t = -13.215, P = 0.000). The FTA was (173.65 +/- 0.92) degrees at the 1st year and (174.34 +/- 0.53) degrees at the latest follow-up. There was significant difference between every two angles of before operation and after operation (t = 28.739, P = 0.000; t = 2.331, P = 0.048). The aLPTA was (87.32 +/- 0.33) degrees at the 1st year and (87.67 +/- 2.82) degrees at the latest follow-up. There was significant difference between every two angles of before operation and after operation (t = 37.264, P = 0.000; t = 2.469, P = 0.039). Indication is important and good surgical technique is critical for good clinical outcome. A detailed plan before operation is essential for the operation. Arthroscopy is helpful for treating the intra-articular pathology. The osteoarthritis is still in progress but in a slow mode. The combined method of arthroscopy and closing-wedge high tibial osteotomy is a reliable way for medial compartment osteoarthritis of the

  19. Effect of open wedge high tibial osteotomy on the lateral tibiofemoral compartment in sheep. Part III: analysis of the microstructure of the subchondral bone and correlations with the articular cartilage and meniscus.

    PubMed

    Ziegler, Raphaela; Goebel, Lars; Seidel, Roland; Cucchiarini, Magali; Pape, Dietrich; Madry, Henning

    2015-09-01

    First, to evaluate whether medial open wedge high tibial osteotomy (HTO) induces alterations of the microstructure of the lateral tibial subchondral bone plate of sheep. Second, to test the hypothesis that specific correlations exist between topographical structural alterations of the subchondral bone, the cartilage and the lateral meniscus. Three experimental groups received biplanar osteotomies of the right proximal tibiae: (a) closing wedge HTO (4.5° of tibial varus), (b) opening wedge HTO (4.5° tibial valgus; standard correction) and (c) opening wedge HTO (9.5° of valgus; overcorrection), each of which was compared to the non-osteotomised contralateral proximal tibiae. After 6 months, subchondral bone structure indices were measured by computed tomography. Correlations between the subchondral bone, the articular cartilage and the lateral meniscus were determined. Increased loading by valgus overcorrection led to an enlarged specific bone surface (BS/BV) in the subarticular spongiosa compared with unloading by varisation. The subchondral bone plate was 3.9-fold thicker in the central region of the lateral tibial plateau than in the submeniscal periphery. Its thickness in the central region significantly correlated with the thickness of the articular cartilage. In the submeniscal region, such correlation did not exist. In general, a higher degree of osteoarthritis (OA) correlated with alterations of the subchondral bone plate microstructure. OA of the submeniscal articular cartilage also correlated with worse matrix staining of the lateral meniscus. Osteoarthritis changes are associated with alterations of the subchondral bone plate microstructure. Specific topographical relationships exist in the central region between the articular cartilage and subchondral bone plate thickness, and in the submeniscal periphery between and the articular cartilage and lateral meniscus. From a clinical perspective, the combined follow-up data from this and the previous two

  20. A Case of Nonunion Avulsion Fracture of the Anterior Tibial Eminence

    PubMed Central

    Atsumi, Satoru; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2016-01-01

    Avulsion fracture of the anterior tibial eminence is an uncommon injury. If bone union does not occur, knee extension will be limited by impingement of the avulsed fragment and knee instability will be induced by dysfunction of the anterior cruciate ligament (ACL). This report describes a 55-year-old woman who experienced an avulsion fracture of the right anterior tibial eminence during recreational skiing. Sixteen months later, she presented at our hospital with limitation of right knee extension. Plain radiography showed nonunion of the avulsion fracture region, and arthroscopy showed that the avulsed fragment impinged the femoral intercondylar notch during knee extension. The anterior region of the bony fragment was debrided arthroscopically until the knee could be extended completely. There was no subsequent instability, and the patient was able to climb a mountain 6 months after surgery. These findings indicate that arthroscopic debridement of an avulsed fragment for nonunion of an avulsion fracture of the anterior tibial eminence is a minimally invasive and effective treatment for middle-aged and elderly patients with a low level of sports activity. PMID:27119035

  1. CO (3 - 2) High-resolution Survey of the Galactic Plane: R1

    NASA Astrophysics Data System (ADS)

    Dempsey, J. T.; Thomas, H. S.; Currie, M. J.

    2013-11-01

    We present the first release (R1) of data from the CO High-Resolution Survey (COHRS), which maps a strip of the inner Galactic plane in 12CO (J = 3 → 2). The data are taken using the Heterodyne Array Receiver Programme on the James Clerk Maxwell Telescope (JCMT) in Hawaii, which has a 14 arcsec angular resolution at this frequency. When complete, this survey will cover |b| <= 0.°5 between 10° < l < 65°. This first release covers |b| <= 0.°5 between 10.°25 < l < 17.°5 and 50.°25 < l < 55.°25, and |b| <= 0.°25 between 17.°5 < l < 50.°25. The data are smoothed to a velocity resolution of 1 km s-1, a spatial resolution of 16 arcsec and achieve a mean rms of ~1 K. COHRS data are available to the community online at http://dx.doi.org/10.11570/13.0002. In this paper we describe the data acquisition and reduction techniques used and present integrated intensity images and longitude-velocity maps. We also discuss the noise characteristics of the data. The high resolution is a powerful tool for morphological studies of bubbles and filaments while the velocity information shows the spiral arms and outflows. These data are intended to complement both existing and upcoming surveys, e.g., the Bolocam Galactic Plane Survey (BGPS), ATLASGAL, the Herschel Galactic Plane Survey (Hi-GAL) and the JCMT Galactic Plane Survey with SCUBA-2 (JPS).

  2. Study of the anatomy of the tibial nerve and its branches in the distal medial leg

    PubMed Central

    Torres, André Leal Gonçalves; Ferreira, Marcus Castro

    2012-01-01

    Objective Determine, through dissection in fresh cadavers, the topographic anatomy of the tibial nerve and its branches at the ankle, in relation to the tarsal tunnel. Methods Bilateral dissections were performed on 26 fresh cadavers and the locations of the tibial nerve bifurcation and its branches were measured in millimeters. For the calcaneal branches, the amount and their respective nerves of origin were also analyzed. Results The tibial nerve bifurcation occurred under the tunnel in 88% of the cases and proximally in 12%. As for the calcaneal branches, the medial presented with one (58%), two (34%) and three (8%) branches, with the most common source occurring in the tibial nerve (90%) and the lower with a single branch per leg and lateral plantar nerve as the most common origin (70%). Level of Evidence, V Expert opinion. PMID:24453596

  3. Quadriceps force and anterior tibial force occur obviously later than vertical ground reaction force: a simulation study.

    PubMed

    Ueno, Ryo; Ishida, Tomoya; Yamanaka, Masanori; Taniguchi, Shohei; Ikuta, Ryohei; Samukawa, Mina; Saito, Hiroshi; Tohyama, Harukazu

    2017-11-18

    Although it is well known that quadriceps force generates anterior tibial force, it has been unclear whether quadriceps force causes great anterior tibial force during the early phase of a landing task. The purpose of the present study was to examine whether the quadriceps force induced great anterior tibial force during the early phase of a landing task. Fourteen young, healthy, female subjects performed a single-leg landing task. Muscle force and anterior tibial force were estimated from motion capture data and synchronized force data from the force plate. One-way repeated measures analysis of variance and the post hoc Bonferroni test were conducted to compare the peak time of the vertical ground reaction force, quadriceps force and anterior tibial force during the single-leg landing. In addition, we examined the contribution of vertical and posterior ground reaction force, knee flexion angle and moment to peak quadriceps force using multiple linear regression. The peak times of the estimated quadriceps force (96.0 ± 23.0 ms) and anterior tibial force (111.9 ± 18.9 ms) were significantly later than that of the vertical ground reaction force (63.5 ± 6.8 ms) during the single-leg landing. The peak quadriceps force was positively correlated with the peak anterior tibial force (R = 0.953, P < 0.001). Multiple linear regression analysis showed that the peak knee flexion moment contributed significantly to the peak quadriceps force (R 2  = 0.778, P < 0.001). The peak times of the quadriceps force and the anterior tibial force were obviously later than that of the vertical ground reaction force for the female athletes during successful single-leg landings. Studies have reported that the peak time of the vertical ground reaction force was close to the time of anterior cruciate ligament (ACL) disruption in ACL injury cases. It is possible that early contraction of the quadriceps during landing might induce ACL disruption as a result of

  4. In Vivo Tibial Fit and Rotational Analysis of a Customized, Patient-Specific TKA versus Off-the-Shelf TKA.

    PubMed

    Schroeder, Lennart; Martin, Gregory

    2018-05-25

    In total knee arthroplasty (TKA), surgeons often face the decision of maximizing tibial component fit and achieving correct rotational alignment at the same time. Customized implants (CIMs) address this difficulty by aiming to replicate the anatomical joint structure, utilizing data from patient-specific knee geometry during the manufacturing. We intraoperatively compared component fit in four tibial zones of a CIM to that of three different off-the-shelf (OTS) TKA designs in 44 knees. Additionally, we assessed the rotational alignment of the tibia using computed tomography (CT)-based computer aided design model analysis. Overall the CIM device showed significantly better component fit than the OTS TKAs. While 18% of OTS designs presented an implant overhang of 3 mm or more, none of the CIM components did ( p  < 0.05). There was a larger percentage of CIMs seen with optimal fit (≤1 mm implant overhang to ≤1 mm tibial bone undercoverage) than in OTS TKAs. Also, OTS implants showed significantly more component underhang of ≥3 mm than the CIM design (37 vs. 18%). The rotational analysis revealed that 45% of the OTS tibial components showed a rotational deviation of more than 5 degrees and 4% of more than 10 degrees to a tibial rotational axis described by Cobb et al. No deviation was seen for the CIM, as the device is designed along this axis. Using the medial one-third of the tibial tubercle as the rotational landmark, 95% of the OTS trays demonstrated a rotational deviation of more than 5 degrees and 73% of more than 10 degrees compared with 73% of CIM tibial trays with more than 5 degrees and 27% with more than 10 degrees. Based on our findings, we believe that the CIM TKA provides both better rotational alignment and tibial fit without causing overhang of the tibial tray than the three examined OTS implants. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Foot and ankle function after tibial overlengthening.

    PubMed

    Emara, Khaled M; Diab, Ramy Ahmed; El Ghazali, Sherif; Farouk, Amr; El Kersh, Mohamed Ahmed

    2014-01-01

    Lengthening the tibia more than 25% of its original length can be indicated for proximal femoral deficiency, poliomyelitis, or femoral infected nonunion. Such lengthening of the tibia can adversely affect the ankle or foot shape and function. The present study aimed to assess the effect of tibial lengthening of more than 25% of its original length on the foot and ankle shape and function compared with the preoperative condition. This was a retrospective study of 13 children with severe proximal focal femoral deficiency, Aitken classification type D, who had undergone limb lengthening from June 2000 to June 2008 using Ilizarov external fixators. The techniques used in tibial lengthening included lengthening without intramedullary rodding and lengthening over a nail. The foot assessment was done preoperatively, at fixator removal, and then annually for 3 years, documenting the range of motion and deformity of the ankle and subtalar joints and big toe and the navicular height, calcaneal pitch angle, and talo-first metatarsal angle. At fixator removal, all cases showed equinocavovarus deformity, with decreased ankle, subtalar, and big toe motion. The mean American Orthopedic Foot and Ankle Society score was significantly reduced. During follow-up, the range of motion, foot deformity, and American Orthopedic Foot and Ankle Society score improved, reaching nearly to the preoperative condition by 2 years of follow-up. The results of our study have shown that tibial overlengthening has an adverse effect on foot and ankle function. This effect was reversible in the patients included in the present study. Lengthening of more than 25% can be safely done after careful discussion with the patients and their families about the probable effects of lengthening on foot and ankle function. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Survivorship comparison of all-polyethylene and metal-backed tibial components in cruciate-substituting total knee arthroplasty—Chinese experience

    PubMed Central

    Shen, Bin; Yang, Jing; Zhou, Zongke; Kang, Pengde; Wang, Liao

    2008-01-01

    Considering its cost saving, the all-polyethylene tibial component is of potential interest in developing countries like China. But to our knowledge, a survivorship comparison of all-polyethylene and metal-backed tibial components in posterior cruciate ligament-substituting total knee arthroplasty (PS-TKA) has not been studied in China previously. Using survivorship analysis, we have studied the midterm outcome of 34 cemented PS-TKA using an all-polyethylene tibial component and of 34 cemented PS-TKA using a metal-backed tibial component which has an identical articular surface with all-polyethylene tibial components. All operations were performed by the same group of surgeons; 58 patients underwent a unilateral operation and five patients a bilateral operation. These patients had a mean follow-up of 5.9 years (range: 5–7 years); three patients were lost to follow-up and one was revised for infection. No significant difference between the two groups was reported regarding HSS scores, ROM, clinical and radiographic parameters measured and survival rates. Although the Asian lifestyle includes more squatting and bending of the knee, the results of this series of TKA using all-polyethylene tibial components in Chinese people are comparable to the satisfactory results of other reported all-polyethylene series whose patients are mainly Western people. Considering its cost saving and excellent clinical result, the all-polyethylene tibial component is of potential interest in developing countries. PMID:18688613

  7. Open wedge high tibial osteotomies: Calcium-phosphate ceramic spacer versus autologous bonegraft.

    PubMed

    Gouin, F; Yaouanc, F; Waast, D; Melchior, B; Delecrin, J; Passuti, N

    2010-10-01

    Valgus tibial osteotomy (VTO) is a well-known procedure for the treatment of medial compartment femoro-tibial osteoarthritis. Good and very good results have been reported with calcium phosphate wedges, which avoid the inconveniences of autologous grafts use. The hypothesis of this study is that with equivalent results in the treatment of osteoarthritis of the knee, the use of calcium phosphate wedges (BMCaPh) to fill the bone defect created by osteotomy would result in fewer specific complications and less pain associated with autologous grafts (AUTO) harvesting. This prospective, controlled, randomised study included one arm that received a macroporous, biphasic calcium phosphate wedge (BMCaPh group) and one arm that received an autologous tricortical graft (AUTO group) for filling. The same plate with locked screws was used for fixation in all cases. All patients underwent at least two years of clinical and radiographic post-operative follow-up. Forty patients were included. Loss of correction occurred in six of the twenty-two patients in the BMCaPh group (27%), resulting in three early surgical revisions, compared to one loss of correction in the AUTO group. Lateral cortical hinge tears were a risk factor for loss of correction for the entire cohort and in the BMCaPh group. (relative risk 13.3 [1.9-92]. Moreover, union took significantly longer and pain lasted significantly longer in the BMCaPh group, although results were comparable at 6 months. A significant number of undesirable events (loss of correction) occurred in this study, limiting the number of included patients. Nevertheless, the results show that although there was no difference in the two groups for overall complications, number of revisions all causes combined, or clinical results, filling with BMCaPh was less tolerated and increased the risk of loss of correction when local mechanical conditions of the knee were unfavourable (lateral cortical hinge tears). Moreover, although it is not possible

  8. The effect of retained intramedullary nails on tibial bone mineral density.

    PubMed

    Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A

    2008-07-01

    Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.

  9. Metrology to quantify wear and creep of polyethylene tibial knee inserts.

    PubMed

    Muratoglu, Orhun K; Perinchief, Rebecca S; Bragdon, Charles R; O'Connor, Daniel O; Konrad, Reto; Harris, William H

    2003-05-01

    Assessment of damage on articular surfaces of ultrahigh molecular weight polyethylene tibial knee inserts primarily has been limited to qualitative methods, such as visual observation and classification of features such as pitting, delamination, and subsurface cracking. Semiquantitative methods also have been proposed to determine the linear penetration and volume of the scar that forms on articular surfaces of tibial knee inserts. The current authors report a new metrologic method that uses a coordinate measuring machine to quantify the dimensions of this scar. The articular surface of the insert is digitized with the coordinate measuring machine before and after regular intervals of testing on a knee simulator. The volume and linear penetration of the scar are calculated by mathematically taking the difference between the digitized surface maps of the worn and unworn articular surfaces. Three conventional polyethylene tibial knee inserts of a posterior cruciate-sparing design were subjected to five million cycles of normal gait on a displacement-driven knee wear simulator in bovine serum. A metrologic method was used to calculate creep and wear contributions to the scar formation on each tibial plateau. Weight loss of the inserts was determined gravimetrically with the appropriate correction for fluid absorption. The total average wear volume was 43 +/- 9 and 41 +/- 4 mm3 measured by the metrologic and gravimetric methods, respectively. The wear rate averaged 8.3 +/- 0.9 and 8.5 +/- 1.6 mm3 per million cycles measured by the metrologic and gravimetric methods, respectively. These comparisons reflected strong agreement between the metrologic and gravimetric methods.

  10. Surgical treatment of refractory tibial stress fractures in elite dancers: a case series.

    PubMed

    Miyamoto, Ryan G; Dhotar, Herman S; Rose, Donald J; Egol, Kenneth

    2009-06-01

    Treatment of tibial stress fractures in elite dancers is centered on rest and activity modification. Surgical intervention in refractory cases has important implications affecting the dancers' careers. Refractory tibial stress fractures in dancers can be treated successfully with drilling and bone grafting or intramedullary nailing. Case series; Level of evidence, 4. Between 1992 and 2006, 1757 dancers were evaluated at a dance medicine clinic; 24 dancers (1.4%) had 31 tibial stress fractures. Of that subset, 7 (29.2%) elite dancers with 8 tibial stress fractures were treated operatively with either intramedullary nailing or drilling and bone grafting. Six of the patients were followed up closely until they were able to return to dance. One patient was available only for follow-up phone interview. Data concerning their preoperative treatment regimens, operative procedures, clinical union, radiographic union, and time until return to dance were recorded and analyzed. The mean age of the surgical patients at the time of stress fracture was 22.6 years. The mean duration of preoperative symptoms before surgical intervention was 25.8 months. Four of the dancers were male and 3 were female. All had failed nonoperative treatment regimens. Five patients (5 tibias) underwent drilling and bone grafting of the lesion, and 2 patients (3 tibias) with completed fractures or multiple refractory stress fractures underwent intramedullary nailing. Clinical union was achieved at a mean of 6 weeks and radiographic union at 5.1 months. Return to full dance activity was at an average of 6.5 months postoperatively. Surgical intervention for tibial stress fractures in dancers who have not responded to nonoperative management allowed for resolution of symptoms and return to dancing with minimal morbidity.

  11. Biomechanical Factors in Tibial Stress Fracture

    DTIC Science & Technology

    2001-08-01

    Relationship between Loading Rates and Tibial Accelerometry in Forefoot Strike Runners. Presented at the Annual American Society of Biomechanics Mtg...of the APTA, Seattle, WA, 2/99. McClay, IS, Williams, DS, and Manal, KT. Lower Extremity Mechanics of Runners with a Converted Forefoot Strike ...Management, Inc, 1998-1999 The Effect of Different Orthotic Devices on Lower Extremity Mechanics of Rearfoot and Forefoot Strikers, $3,500. Foot Management

  12. Comparison of bone healing and outcomes between allogenous bone chip and hydroxyapatite chip grafts in open wedge high tibial osteotomy.

    PubMed

    Lee, O-Sung; Lee, Kyung Jae; Lee, Yong Seuk

    2017-11-03

    Allogenous bone chips and hydroxyapatite (HA) chips have been known as good options for filling an inevitable void after open wedge high tibial osteotomy (OWHTO). However, there are concerns regarding bone healing after the use of these grafts. The purpose of this study was to compare the bone healing represented by the osteoconductivity and absorbability between allogenous bone chips and HA chips in OWHTO. The outcomes of bone healing of 53 patients who received an allogenous bone chip graft and 41 patients who received an HA chip graft were retrospectively evaluated, and the results were compared between the two groups. Osteoconductivity and absorbability were serially evaluated for the assessment of bone healing at 6 weeks, 3 months, 6 months, and 1 year postoperatively. The osteoconductivity of the allogenous bone chips was greater than that of the HA chips at 6 weeks postoperatively (p < 0.05). However, there were no statistically significant differences from 3 months to 1 year postoperatively. The absorbability showed no statistically significant differences 6 weeks and 3 months after OWHTO; however, the allogenous bone chip group showed a greater absorbability at 6 months and 1 year postoperatively (42.8 ± 14.2 vs. 34.6 ± 13.8, p = 0.006 at 6 months postoperatively; 54.6 ± 14.4 vs. 43.0 ± 14.0, p < 0.001 at 1 year postoperatively). However, the two graft materials showed similar results of HKA angle, WBL ratio, posterior tibial slope.

  13. A New Selective Area Lateral Epitaxy Approach for Depositing a-Plane GaN over r-Plane Sapphire

    NASA Astrophysics Data System (ADS)

    Chen, Changqing; Zhang, Jianping; Yang, Jinwei; Adivarahan, Vinod; Rai, Shiva; Wu, Shuai; Wang, Hongmei; Sun, Wenhong; Su, Ming; Gong, Zheng; Kuokstis, Edmundas; Gaevski, Mikhail; Khan, Muhammad Asif

    2003-07-01

    We report a new epitaxy procedure for growing extremely low defect density a-plane GaN films over r-plane sapphire. By combining selective area growth through a SiO2 mask opening to produce high height to width aspect ratio a-plane GaN pillars and lateral epitaxy from their c-plane facets, we obtained fully coalesced a-plane GaN films. The excellent structural, optical and electrical characteristics of these selective area lateral epitaxy (SALE) deposited films make them ideal for high efficiency III-N electronic and optoelectronic devices.

  14. The role of fixation and bone quality on the mechanical stability of tibial knee components.

    PubMed

    Lee, R W; Volz, R G; Sheridan, D C

    1991-12-01

    Tibial component loosening remains one of the major causes of failure of cemented and noncemented total knee arthroplasties. In this study, the authors identified the role of implant design, method of fixation, and bone density as it related to implant stability. The physical properties of "good" and "bad" bone were simulated using a "good" and "bad" foam model of the proximal tibia, fabricated in the laboratory from DARO RF-100 foam. A generic tibial component permitting various fixation designs was implanted into "good" and "bad" variable density foam tibial models in both cemented and noncemented modes. The mechanical stability of the implants was determined using a Materials Testing Machine by the application of an eccentrically applied cyclic load. The micromotion (subsidence and lift-off) of the tibial implants was recorded using two Linear Variable Differential Transformers. Statistically significant differences in implant stability were recorded as a function of fixation method. The most rigid implant fixation was achieved using four peripherally placed, 6.5-mm cancellous screws. The addition of a central stem added stability only in the case of "poor" quality foam. The mechanical stability of noncemented implants related directly to the density of the foam. Implant stability was greatly enhanced in "poor" quality foam by the use of cement. The method of implant fixation and bone density are critical determinants to tibial implant stability.

  15. Tibial rotation under combined in vivo loading after single- and double-bundle anterior cruciate ligament reconstruction.

    PubMed

    Tsarouhas, Alexander; Iosifidis, Michael; Spyropoulos, Giannis; Kotzamitelos, Dimitrios; Tsatalas, Themistoklis; Giakas, Giannis

    2011-12-01

    To evaluate in vivo the differences in tibial rotation between single- and double-bundle anterior cruciate ligament (ACL)-reconstructed knees under combined loading conditions. An 8-camera optoelectronic system and a force plate were used to collect kinematic and kinetic data from 14 patients with double-bundle ACL reconstruction, 14 patients with single-bundle reconstruction, 12 ACL-deficient subjects, and 12 healthy control individuals while performing 2 tasks. The first included walking, 60° pivoting, and stair ascending, and the second included stair descending, 60° pivoting, and walking. The 2 variables evaluated were the maximum range of internal-external tibial rotation and the maximum knee rotational moment. Tibial rotation angles were not significantly different across the 4 groups (P = .331 and P = .851, respectively) or when side-to-side differences were compared within groups (P = .216 and P = .371, respectively) for the ascending and descending maneuvers, nor were rotational moments among the 4 groups (P = .418 and P = .290, respectively). Similarly, for the descending maneuver, the rotational moments were not significantly different between sides (P = .192). However, for the ascending maneuver, rotational moments of the affected sides were significantly lower by 20.5% and 18.7% compared with their intact counterparts in the single-bundle (P = .015) and double-bundle (P = .05) groups, respectively. High-intensity activities combining stair ascending or descending with pivoting produce similar tibial rotation in single- and double-bundle ACL-reconstructed patients. During such maneuvers, the reconstructed knee may be subjected to significantly lower rotational loads compared with the intact knee. Level III, retrospective comparative study. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. High-speed light field camera and frequency division multiplexing for fast multi-plane velocity measurements.

    PubMed

    Fischer, Andreas; Kupsch, Christian; Gürtler, Johannes; Czarske, Jürgen

    2015-09-21

    Non-intrusive fast 3d measurements of volumetric velocity fields are necessary for understanding complex flows. Using high-speed cameras and spectroscopic measurement principles, where the Doppler frequency of scattered light is evaluated within the illuminated plane, each pixel allows one measurement and, thus, planar measurements with high data rates are possible. While scanning is one standard technique to add the third dimension, the volumetric data is not acquired simultaneously. In order to overcome this drawback, a high-speed light field camera is proposed for obtaining volumetric data with each single frame. The high-speed light field camera approach is applied to a Doppler global velocimeter with sinusoidal laser frequency modulation. As a result, a frequency multiplexing technique is required in addition to the plenoptic refocusing for eliminating the crosstalk between the measurement planes. However, the plenoptic refocusing is still necessary in order to achieve a large refocusing range for a high numerical aperture that minimizes the measurement uncertainty. Finally, two spatially separated measurement planes with 25×25 pixels each are simultaneously acquired with a measurement rate of 0.5 kHz with a single high-speed camera.

  17. Combined CT-based and image-free navigation systems in TKA reduces postoperative outliers of rotational alignment of the tibial component.

    PubMed

    Mitsuhashi, Shota; Akamatsu, Yasushi; Kobayashi, Hideo; Kusayama, Yoshihiro; Kumagai, Ken; Saito, Tomoyuki

    2018-02-01

    Rotational malpositioning of the tibial component can lead to poor functional outcome in TKA. Although various surgical techniques have been proposed, precise rotational placement of the tibial component was difficult to accomplish even with the use of a navigation system. The purpose of this study is to assess whether combined CT-based and image-free navigation systems replicate accurately the rotational alignment of tibial component that was preoperatively planned on CT, compared with the conventional method. We compared the number of outliers for rotational alignment of the tibial component using combined CT-based and image-free navigation systems (navigated group) with those of conventional method (conventional group). Seventy-two TKAs were performed between May 2012 and December 2014. In the navigated group, the anteroposterior axis was prepared using CT-based navigation system and the tibial component was positioned under control of the navigation. In the conventional group, the tibial component was placed with reference to the Akagi line that was determined visually. Fisher's exact probability test was performed to evaluate the results. There was a significant difference between the two groups with regard to the number of outliers: 3 outliers in the navigated group compared with 12 outliers in the conventional group (P < 0.01). We concluded that combined CT-based and image-free navigation systems decreased the number of rotational outliers of tibial component, and was helpful for the replication of the accurate rotational alignment of the tibial component that was preoperatively planned.

  18. Quantitative comparison of the microscopic anatomy of the human ACL femoral and tibial entheses.

    PubMed

    Beaulieu, Mélanie L; Carey, Grace E; Schlecht, Stephen H; Wojtys, Edward M; Ashton-Miller, James A

    2015-12-01

    The femoral enthesis of the human anterior cruciate ligament (ACL) is known to be more susceptible to injury than the tibial enthesis. To determine whether anatomic differences might help explain this difference, we quantified the microscopic appearance of both entheses in 15 unembalmed knee specimens using light microscopy, toluidine blue stain and image analysis. The amount of calcified fibrocartilage and uncalcified fibrocartilage, and the ligament entheseal attachment angle were then compared between the femoral and tibial entheses via linear mixed-effects models. The results showed marked differences in anatomy between the two entheses. The femoral enthesis exhibited a 3.9-fold more acute ligament attachment angle than the tibial enthesis (p<0.001), a 43% greater calcified fibrocartilage tissue area (p<0.001), and a 226% greater uncalcified fibrocartilage depth (p<0.001), with the latter differences being particularly pronounced in the central region. We conclude that the ACL femoral enthesis has more fibrocartilage and a more acute ligament attachment angle than the tibial enthesis, which provides insight into why it is more vulnerable to failure. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. Severe lateral tibial bowing with short stature in two siblings--a provisionally novel syndrome.

    PubMed

    Zitano, Lia; Loder, Randall T; Cohen, Mervyn D; Weaver, David D

    2012-09-01

    In this report, we describe two siblings with short stature and severe lateral tibial bowing. In the younger sibling, the bowing was bilateral, while in the older sib, it was unilateral. However, both showed bilateral abnormalities of the distal tibial epiphyses and growth plates. Pseudoarthrosis of the left distal tibial metaphysis and subsequent spontaneous resolution of the abnormality occurred in the younger sibling. The fibulas of both children were of normal diameter and were straight, except for the distal ends. Surgery has almost completely corrected the lower leg bowing in both patients. The type of tibial bowing seen in these children can be associated with a number of syndromes, such as neurofibromatosis type I, Weismann-Netter syndrome, and a variety of environmental caused disorders, such as vitamin D deficient rickets. However, the severity of the bowing present in our patients and the absence of other clinical features differentiates this condition from those reported in the literature. We posit that the condition in the children presented here represents an as yet undescribed syndrome, which is likely to be of genetic origin. Copyright © 2012 Wiley Periodicals, Inc.

  20. Tibial nerve stimulation to inhibit the micturition reflex by an implantable wireless driver microstimulator in cats

    PubMed Central

    Li, Xing; Liao, Li-Min; Chen, Guo-Qing; Wang, Zhao-Xia; Lu, Tian-Ji; Deng, Han; Loeb, Gerald-E

    2016-01-01

    Abstract Background: Traditional tibial nerve stimulation (TNS) has been used to treat overactive bladder syndrome (OAB), but there are some shortcomings. Thus, a novel alternative is needed for the treatment of OAB. The study investigated the effects of a new type of tibial nerve microstimulator on the micturition reflex in cats. Methods: An implantable wireless driver microstimulator was implanted around the tibial nerve in 9 α-chloralose anesthetized cats. Cystometry was performed by infusing 0.9% normal saline (NS) or 0.25% acetic acid (AA) through a urethral catheter. Multiple cystometrograms were performed before, during, and after TNS to determine the inhibitory effect of the microstimulator on the micturition reflex. Results: TNS at 2 threshold (T) intensity significantly increased the bladder capacity (BC) during NS infusion. Bladder overactivity was irritated by the intravesical infusion of 0.25% AA, which significantly reduced the BC compared with the NS infusion. TNS at 2 T intensity suppressed AA-induced bladder overactivity and significantly increased the BC compared with the AA control. Conclusion: The implantable wireless driver tibial nerve microstimulator appears to be effective in inhibiting the micturition reflex during physiologic and pathologic conditions. The implantable wireless driver tibial nerve microstimulator could be used to treat OAB. PMID:27537576

  1. Thermoelastic stress analysis to validate tibial fixation technique in total ankle prostheses - a pilot study.

    PubMed

    Ficklscherer, Andreas; Wegener, Bernd; Niethammer, Thomas; Pietschmann, Matthias F; Müller, Peter E; Jansson, Volkmar; Trouillier, Hans-Heinrich

    2013-03-01

    Recent literature has shown a persistently high rate of aseptic loosening of the tibial component in total ankle prostheses. We analyzed the interface between the tibial bone and tibial component with a thermoelastic stress analysis to demonstrate load transmission onto the distal tibia. In this regard, we used two established ankle prostheses, which were implanted in two human cadaveric and in two third-generation composite tibia bones (Sawbones®, Sweden). Subsequently, the bones were attached to a hydropulser and a sinusoidal load of 700 N was applied. Both prostheses had an inhomogeneous load transmission onto the distal tibia. Instead of distributing load equally to the subarticular bone, forces were focused around the bolting stem, accumulating as stress maxima with forces up to 90 MPa. Furthermore, we were able to demonstrate load transmission into the metaphysis of the bone. As demonstrated in this study, anchoring systems with stems used in all established total ankle prostheses lead to an inhomogeneous load transmission onto the distal tibia, and furthermore, to a distribution of load into the weaker metaphyseal bone. For these reasons, we favor a prosthetic design with minimal bone resection and without any stem or stem-like anchoring system, which facilitates a homogeneous load transmission onto the distal tibia. Thermoelastic stress analysis proved to be a fast and easy-to-perform method to visualize load transmission.

  2. Rupture of the anterior tibial tendon: three clinical cases, anatomical study, and literature review.

    PubMed

    Anagnostakos, Konstantinos; Bachelier, Felix; Fürst, Oliver Alexander; Kelm, Jens

    2006-05-01

    We report three cases of anterior tibial tendon ruptures and the results of an anatomical study in regard to the tendon's insertion site and a literature review. Three patients were referred to our hospital with anterior tibial tendon ruptures. In the anatomical study, 53 feet were dissected, looking in particular for variants of the bony insertion of the tendon. Two patients had surgical treatment (one primary repair and one semimembranosus tendon graft) and one conservative treatment. After a mean followup of 14 weeks all patients had satisfactory outcomes. In the anatomical study, we noted three different insertion sites: in 36 feet the tendon inserted into the medial side of the cuneiform and the base of the first metatarsal bone and in 13 feet only into the medial side of the cuneiform bone. In the remaining four feet the tendon inserted into the cuneiform and the first metatarsal bone, but an additional tendon was noted taking its origin from the anterior tibial tendon near its insertion into the medial cuneiform and attaching to the proximal part of the first metatarsal. According to literature, surgical repair is the treatment of choice for acute ruptures and for patients with high activity levels. For chronic ruptures and patients with low demands, conservative management may lead to an equally good outcome. Knowledge of the anatomy in this region may be helpful for diagnosis and for the interpretation of intraoperative findings and choosing the most appropriate surgical procedure.

  3. The risk of sacrificing the PCL in cruciate retaining total knee arthroplasty and the relationship to the sagittal inclination of the tibial plateau.

    PubMed

    Sessa, Pasquale; Fioravanti, Giulio; Giannicola, Giuseppe; Cinotti, Gianluca

    2015-01-01

    In cruciate retaining total knee arthroplasty (TKA), a partial avulsion of PCL may occur when en-bloc tibial osteotomy is performed. We evaluated the effects of a tibial cut performed with different degrees of posterior slope on PCL insertion and whether the results are affected by the sagittal inclination of the patient's tibial plateau. We selected 83 MRIs of knees showing mild or no degenerative changes. The effects of a simulated tibial cut performed with a posterior slope of 0°, 3°, 5° and parallel to the patient's tibial plateau inclination on PCL insertion in the proximal tibia were investigated. The results were correlated with the degree of posterior inclination of the tibial plateau. Every angle we used for the tibial cut caused a PCL avulsion greater than 50%. The percentage of PCL avulsion significantly increased with increasing the posterior slope of the tibial cut. Patients with sagittal tibial plateau inclination <5° showed greater PCL avulsion than those with sagittal inclination >8°. Most of the PCL insertion is likely to be sacrificed when resection of the proximal tibia is performed en-block. The risk of PCL avulsion is reduced in patients showing a marked posterior inclination of the tibial plateau, but even in this group of patients a surgical technique aimed at sparing most of the PCL insertion is necessary. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Do Tibial Plateau Fractures Worsen Outcomes of Knee Ligament Injuries? A Matched Cohort Analysis

    PubMed Central

    Cinque, Mark E.; Godin, Jonathan A.; Moatshe, Gilbert; Chahla, Jorge; Kruckeberg, Bradley M.; Pogorzelski, Jonas; LaPrade, Robert F.

    2017-01-01

    Background: Tibial plateau fractures account for a small portion of all fractures; however, these fractures can pose a surgical challenge when occurring concomitantly with ligament injuries. Purpose/Hypothesis: The purpose of this study was to compare 2-year outcomes of soft tissue reconstruction with or without a concomitant tibial plateau fracture and open reduction internal fixation. We hypothesized that patients with a concomitant tibial plateau fracture at the time of soft tissue surgery would have inferior outcomes compared with patients without an associated tibial plateau fracture. Study Design: Cohort study; Level of evidence, 3. Methods: Forty patients were included in this study: 8 in the fracture group and 32 in the matched control group. Inclusion criteria for the fracture group included patients who were at least 18 years old at the time of surgery and sustained a tibial plateau fracture and a concomitant injury of the anterior cruciate ligament, posterior cruciate ligament, medial collateral ligament, or fibular collateral ligament in isolation or any combination of cruciate or collateral ligaments and who subsequently underwent isolated or combined ligament reconstruction. Patients were excluded if they underwent prior ipsilateral knee surgery, sustained additional bony injuries, or sustained an isolated extra-articular ligament injury at the time of injury. Each patient with a fracture was matched with 4 patients from a control group who had no evidence of a tibial plateau fracture but underwent the same soft tissue reconstruction procedure. Results: Patients in the fracture group improved significantly from preoperatively to postoperatively with respect to Short Form–12 (P < .05) and Western Ontario and McMaster Universities Osteoarthritis Index total scores (P < .05). The Lysholm (P = .075) and Tegner scores (P = .086) also improved, although this was not statistically significant. Patients in the control group improved significantly from

  5. Achilles lengthening/posterior tibial tenotomy with immediate weightbearing for patients with significant comorbidities.

    PubMed

    Redfern, John C; Thordarson, David B

    2008-03-01

    Fixed equinovarus deformities can be challenging to treat especially in medically debilitated patients. The purpose of this study was to evaluate Achilles lengthening with posterior tibial tenotomy and immediate weightbearing in this difficult group of patients. Thirteen extremities in 10 patients underwent Achilles lengthening and posterior tibial tenotomy for fixed equinovarus deformities with significant medical comorbidities. Pre- and postoperative ambulatory status and deformities were noted. Average age at the time of surgery was 65 with an average duration of deformity 6.3 years. The average equinus corrected from 26 degrees to 1.2 degrees and the average varus deformity improved from -8.5 degrees to 2.7 degrees. All patients except one who was wheelchair-bound had a significant improvement in ambulatory status. Achilles lengthening with posterior tibial tenotomy allowed for immediate postoperative weightbearing with improvement in deformity and ambulatory status in this complicated patient group.

  6. Chronic exertional compartment syndrome with medial tibial stress syndrome in twins.

    PubMed

    Banerjee, Purnajyoti; McLean, Christopher

    2011-06-14

    Chronic exertional compartment syndrome and medial tibial stress syndrome are uncommon conditions that affect long-distance runners or players involved in team sports that require extensive running. We report 2 cases of bilateral chronic exertional compartment syndrome, with medial tibial stress syndrome in identical twins diagnosed with the use of a Kodiag monitor (B. Braun Medical, Sheffield, United Kingdom) fulfilling the modified diagnostic criteria for chronic exertional compartment syndrome as described by Pedowitz et al, which includes: (1) pre-exercise compartment pressure level >15 mm Hg; (2) 1 minute post-exercise pressure >30 mm Hg; and (3) 5 minutes post-exercise pressure >20 mm Hg in the presence of clinical features. Both patients were treated with bilateral anterior fasciotomies through minimal incision and deep posterior fasciotomies with tibial periosteal stripping performed through longer anteromedial incisions under direct vision followed by intensive physiotherapy resulting in complete symptomatic recovery. The etiology of chronic exertional compartment syndrome is not fully understood, but it is postulated abnormal increases in intramuscular pressure during exercise impair local perfusion, causing ischemic muscle pain. No familial predisposition has been reported to date. However, some authors have found that no significant difference exists in the relative perfusion, in patients, diagnosed with chronic exertional compartment syndrome. Magnetic resonance images of affected compartments have indicated that the pain is not due to ischemia, but rather from a disproportionate oxygen supply versus demand. We believe this is the first report of chronic exertional compartment syndrome with medial tibial stress syndrome in twins, raising the question of whether there is a genetic predisposition to the causation of these conditions. Copyright 2011, SLACK Incorporated.

  7. Tibial slope correction combined with second revision ACL produces good knee stability and prevents graft rupture.

    PubMed

    Dejour, David; Saffarini, Mo; Demey, Guillaume; Baverel, Laurent

    2015-10-01

    Revision ACL reconstruction requires careful analysis of failure causes particularly in cases of two previous graft ruptures. Intrinsic factors as excessive tibial slope or narrow femoral notch increase failure risks but are rarely addressed in revision surgery. The authors report outcomes, at minimum follow-up of 2 years, for second revision ACL reconstructions combined with tibial deflexion osteotomy for correction of excessive slope (>12°). Nine patients that underwent second revision ACL reconstruction combined with tibial deflexion osteotomy were retrospectively studied. The mean age was 30.3 ± 4.4 years (median 28; range 26-37), and mean follow-up was 4.0 ± 2.0 years (median 3.6; range 2.0-7.6). Autografts were harvested from the quadriceps tendon (n = 8) or hamstrings (n = 1), and tibial osteotomy was done by anterior closing wedge, without detachment of the patellar tendon, to obtain a slope of 3° to 5°. All patients had fused osteotomies, stable knees, and there were no intraoperative or postoperative complications. The mean posterior tibial slope decreased from 13.2° ± 2.6° (median 13°; range 12°-18°) preoperatively to 4.4° ± 2.3° (median 4°; range 2°-8°) postoperatively. The mean Lysholm score was 73.8 ± 5.8 (median 74; range 65-82), and the IKDC-SKF was 71.6 ± 6.1 (median 72.8; range 62.2-78.5). The satisfactory results of second revision ACL reconstruction combined with tibial deflexion osteotomy at minimum follow-up of 2 years suggest that tibia slope correction protects reconstructed ACL from fatigue failure in this study. The authors stress the importance of careful analysis failure causes prior to revision ACL reconstruction, and recommend correction of tibial slope if it exceeds 12°, to reduce the risks of graft retear. III.

  8. Evaluating Stiffness of Fibreglass and Thermoplastic Splint Materials and Inter-fragmentary Motion in a Canine Tibial Fracture Model.

    PubMed

    Wagoner, Amanda L; Allen, Matthew J; Zindl, Claudia; Litsky, Alan; Orsher, Robert; Ben-Amotz, Ron

    2018-04-16

     Various materials are used to construct splints for mid-diaphyseal tibial fracture stabilization. The objective of this study was to compare construct stiffness and inter-fragmentary bone motion when fibreglass (FG) or thermoplastic (TP) splints are applied to either the lateral or cranial aspect of the tibia in a mid-diaphyseal fracture model.  A coaptation bandage was applied to eight cadaveric canine pelvic limbs, with a custom-formed splint made of either FG or TP material applied to either the lateral or cranial aspect of the osteotomized tibia. Four-point bending tests were performed to evaluate construct stiffness and inter-fragmentary motion in both frontal and sagittal planes.  For a given material, FG or TP, construct stiffness was not affected by splint location. Construct stiffness was significantly greater with cranial FG splints than with cranial TP splints ( p  < 0.05), but this difference was not significant when comparing splints applied laterally ( p  = 0.15). Inter-fragmentary motions in the sagittal and frontal planes were similar across splint types for cranial splints, but for lateral splints there was a 64% reduction in frontal plane motion when FG was used as the splint material ( p  = 0.03).  FG produces a stiffer construct, but the difference is not reflected in a reduction in inter-fragmentary motion. For lateral splints, FG splints are associated with reduced inter-fragmentary motion as compared with TP and may therefore have slight superiority for this application. Schattauer GmbH Stuttgart.

  9. High-Q, in-plane modes of nanomechanical resonators operated in air

    NASA Astrophysics Data System (ADS)

    Waggoner, Philip S.; Tan, Christine P.; Bellan, Leon; Craighead, Harold G.

    2009-05-01

    Nanomechanical resonators have traditionally been limited to use in vacuum due to low quality factors that come as a result of viscous damping effects in air or liquid. We have fabricated arrays of 90 nm thick trampoline-shaped resonators, studied their resonant frequency spectrum as a function of pressure, and found that some high frequency modes exhibit quality factors over 2000 at atmospheric pressure. We have excited the in-plane resonances of these devices, verified their identities both experimentally and with finite element modeling, and demonstrated their advantageous characteristics for ambient sensing. Even after deposition of a relatively thick polymer layer, the in-plane resonant modes still boast quality factors on the order of 2000. These results show promise for the use of nanomechanical resonant sensors in real-time atmospheric sensing applications.

  10. Location of the tibial tunnel aperture affects extrusion of the lateral meniscus following reconstruction of the anterior cruciate ligament.

    PubMed

    Kodama, Yuya; Furumatsu, Takayuki; Miyazawa, Shinichi; Fujii, Masataka; Tanaka, Takaaki; Inoue, Hiroto; Ozaki, Toshifumi

    2017-08-01

    The anterior root of the lateral meniscus provides functional stability to the meniscus. In this study, we evaluated the relationship between the position of the tibial tunnel and extrusion of the lateral meniscus after anterior cruciate ligament reconstruction, where extrusion provides a proxy measure of injury to the anterior root. The relationship between extrusion and tibial tunnel location was retrospectively evaluated from computed tomography and magnetic resonance images of 26 reconstructed knees, contributed by 25 patients aged 17-31 years. A measurement grid was used to localize the position of the tibial tunnel based on anatomical landmarks identified from the three-dimensional reconstruction of axial computed tomography images of the tibial plateaus. The reference point-to-tibial tunnel distance (mm) was defined as the distance from the midpoint of the lateral edge of the grid to the posterolateral aspect of the tunnel aperture. The optimal cutoff of this distance to minimize post-operative extrusion was identified using receiver operating curve analysis. Extrusion of the lateral meniscus was positively correlated to the reference point-to-tibial tunnel distance (r 2  = 0.64; p < 0.001), with a cutoff distance of 5 mm having a sensitivity to extrusion of 83% and specificity of 93%. The mean extrusion for a distance >5 mm was 0.40 ± 0.43 mm, compared to 1.40 ± 0.51 mm for a distance ≤5 mm (p < 0.001). Therefore, a posterolateral location of the tibial tunnel aperture within the footprint of the anterior cruciate ligament decreases the reference point-to-tibial tunnel distance and increases extrusion of the lateral meniscus post-reconstruction. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1625-1633, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Analysis of Outcomes for High Tibial Osteotomies Performed With Cartilage Restoration Techniques.

    PubMed

    Kahlenberg, Cynthia A; Nwachukwu, Benedict U; Hamid, Kamran S; Steinhaus, Michael E; Williams, Riley J

    2017-02-01

    To evaluate reported medium- to long-term outcomes after high tibial osteotomy (HTO) with associated cartilage restoration procedures. A review of the MEDLINE database was performed. The inclusion criteria were English language, clinical outcome study with HTO as the primary procedure, use of a form of cartilage repair included, and the mean follow-up period of at least 2 years. Each identified study was reviewed for study design, patient demographics, type of procedures performed, clinical outcomes, progression to total knee arthroplasty, and complications. Eight hundred and twenty-seven patients (839 knees) were included. The most common cartilage preservation technique used in conjunction with HTO was microfracture (4 studies; 22.2%). The mean Lyscholm scores, reported in 50% of the studies, ranged from 40 to 65.7 preoperatively and improved to a range of 67 to 94.6 postoperatively. Four studies (22.2%) used a visual analog scale for evaluation of pain and all had a mean visual analog scale of less than 3 postoperatively. Among studies evaluating conversion to arthroplasty, the rate of conversion was 6.8% and the range of mean number of years from HTO to conversion was 4.9 to 13.0. The overall reported complication rate was 10.3%. HTO with cartilage restoration procedures provides reliable improvement in functional status in the medium- to long-term period after surgery and has potential to delay or avoid the need for knee arthroplasty surgery. Level IV, systematic review of Level I to IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Point-to-plane and plane-to-plane electrostatic charge injection atomization for insulating liquids

    NASA Astrophysics Data System (ADS)

    Malkawi, Ghazi

    An electrostatic charge injection atomizer was fabricated and used to introduce and study the electrostatic charge injection atomization methods for highly viscous vegetable oils and high conductivity low viscosity aviation fuel, JP8. The total, spray and leakage currents and spray breakup characteristics for these liquids were investigated and compared with Diesel fuel data. Jet breakup and spray atomization mechanism showed differences for vegetable oils and lower viscosity hydrocarbon fuels. For vegetable oils, a bending/spinning instability phenomenon was observed similar to the phenomenon found in liquid jets of high viscosity polymer solutions. The spray tip lengths and cone angles were presented qualitatively and quantitatively and correlated with the appropriate empirical formulas. The different stages of the breakup mechanisms for such oils, as a function of specific charges and flow rates, were discussed. In order to make this method of atomization more suitable for practical use in high flow rate applications, a blunt face electrode (plane-to-plane) was used as the charge emitter in place of a single pointed electrode (point-to-plane). This allowed the use of a multi-orifice emitter that maintained a specific charge with the flow rate increase which could not be achieved with the needle electrode. The effect of the nozzle geometry, liquid physical properties and applied bulk flow on the spray charge, total charge, maximum critical spray specific charge and electrical efficiency compared with the needle point-to-plane atomizer results was presented. Our investigation revealed that the electrical efficiency of the atomizer is dominated by the charge forced convection rate rather than charge transport by ion motilities and liquid motion by the electric field. As a result of the electric coulomb forces between the electrified jets, the multi-orifice atomizer provided a unique means of dispersing the fuel in a hollow cone with wide angles making the new

  13. Patellofemoral Osteoarthritis Progression and Alignment Changes after Open-Wedge High Tibial Osteotomy Do Not Affect Clinical Outcomes at Mid-term Follow-up.

    PubMed

    Goshima, Kenichi; Sawaguchi, Takeshi; Shigemoto, Kenji; Iwai, Shintaro; Nakanishi, Akira; Ueoka, Ken

    2017-10-01

    To evaluate the clinical and radiological outcomes of open-wedge high tibial osteotomy (OWHTO) with respect to the patellofemoral joint and to assess whether patellofemoral osteoarthritis (OA) progression and alignment changes after OWHTO affect clinical outcomes. Inclusion criteria were consecutive patients who underwent OWHTO from March 2005 to September 2013. Exclusion criteria were loss to follow-up within 2 years and absence of second-look arthroscopy findings at the time of plate removal. The clinical parameters, including anterior knee pain while climbing stairs, Japanese Orthopedic Association score, and Oxford Knee Score, were evaluated. Radiological outcomes, including weight-bearing line ratio, modified Blackburne-Peel ratio, posterior tibial slope, tilting angle, lateral shift ratio, and patellofemoral OA (Kellgren-Lawrence grade), were evaluated preoperatively and at the final follow-up. Cartilage status (International Cartilage Repair Society grade) was evaluated at the initial HTO and at plate removal. Fifty-three patients (60 knees) were included in this study. The mean follow-up was 58.2 ± 22.4 months. Two knees (3%) presented with mild anterior knee pain after OWHTO. The mean Japanese Orthopedic Association score (66.9 ± 11.2 to 91.2 ± 9.7) significantly improved (P < .001), and the mean Oxford Knee Score at the final follow-up was 42.0 ± 5.3. The mean modified Blackburne-Peel ratio (0.9 ± 0.1 to 0.7 ± 0.1, P < .001) and tilting angle (6.8 ± 3.7 to 5.6 ± 3.4, P = .033) significantly decreased after OWHTO, whereas no significant changes in posterior tibial slope (P = .511) and lateral shift ratio (P = .522) were observed. Radiologically, patellofemoral OA had progressed in 15 knees (27%), and arthroscopically patellofemoral cartilage degeneration had progressed in 27 knees (45%). However, there was no significant correlation between changes in patellofemoral alignment and clinical outcomes. Changes in patellofemoral alignment and

  14. Posterior tibial slope and femoral sizing affect posterior cruciate ligament tension in posterior cruciate-retaining total knee arthroplasty.

    PubMed

    Kuriyama, Shinichi; Ishikawa, Masahiro; Nakamura, Shinichiro; Furu, Moritoshi; Ito, Hiromu; Matsuda, Shuichi

    2015-08-01

    During cruciate-retaining total knee arthroplasty, surgeons sometimes encounter increased tension of the posterior cruciate ligament. This study investigated the effects of femoral size, posterior tibial slope, and rotational alignment of the femoral and tibial components on forces at the posterior cruciate ligament in cruciate-retaining total knee arthroplasty using a musculoskeletal computer simulation. Forces at the posterior cruciate ligament were assessed with the standard femoral component, as well as with 2-mm upsizing and 2-mm downsizing in the anterior-posterior dimension. These forces were also determined with posterior tibial slope angles of 5°, 7°, and 9°, and lastly, were measured in 5° increments when the femoral (tibial) components were positioned from 5° (15°) of internal rotation to 5° (15°) of external rotation. Forces at the posterior cruciate ligament increased by up to 718N with the standard procedure during squatting. The 2-mm downsizing of the femoral component decreased the force at the posterior cruciate ligament by up to 47%. The 2° increment in posterior tibial slope decreased the force at the posterior cruciate ligament by up to 41%. In addition, posterior cruciate ligament tension increased by 11% during internal rotation of the femoral component, and increased by 18% during external rotation of the tibial component. These findings suggest that accurate sizing and bone preparation are very important to maintain posterior cruciate ligament forces in cruciate-retaining total knee arthroplasty. Care should also be taken regarding malrotation of the femoral and tibial components because this increases posterior cruciate ligament tension. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Baseline Vitamin D Status is Predictive of Longitudinal Change in Tibial BMD in Knee Osteoarthritis (OA)

    USDA-ARS?s Scientific Manuscript database

    With its lack of effective treatment and high prevalence, the public health impact of OA is substantial. Peri-articular bone in OA can be evaluated with the medial:lateral tibial BMD ratio (M:L BMD) obtained from dual x-ray absorptiometry (DXA). Higher M:L BMD is associated with medial OA features...

  16. High brightness nonpolar a-plane (11-20) GaN light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Jung, Sukkoo; Chang, Younghak; Bang, Kyu-Hyun; Kim, Hyung-Gu; Choi, Yoon-Ho; Hwang, Sung-Min; Baik, Kwang Hyeon

    2012-02-01

    We report on high brightness nonpolar a-plane InGaN/GaN LEDs using patterned lateral overgrowth (PLOG) epitaxy. High crystal-quality and smooth surfaces for a-plane GaN (a-GaN) films were achieved using PLOG with an array of hexagonal SiO2 patterns. The XRC FWHMs of as-grown PLOG a-GaN films were found to be 414 and 317 arcsec (450 and 455 arcsec for planar a-GaN films) along the c-axis and m-axis directions, respectively. Plan-view CL clearly reveals the periodic hexagonal patterns with higher band edge emission intensity, implying that the luminescence properties of a-GaN films lying above the SiO2 mask are improved. The light output powers of a-InGaN/GaN PLOG LEDs were measured to be 7.5 mW and 20 mW at drive currents of 20 mA and 100 mA, respectively. A negligible blue-shift was observed in the peak emission wavelength with increasing drive current up to 100 mA, indicating that there are no strong internal fields in nonpolar a-InGaN/GaN LEDs. We believe that nonpolar a-plane InGaN/GaN LEDs hold promise for efficient nitride emitters if the growth conditions are further optimized.

  17. Arthroscopic pullout repair of a complete radial tear of the tibial attachment site of the medial meniscus posterior horn.

    PubMed

    Kim, Young-Mo; Rhee, Kwang-Jin; Lee, June-Kyu; Hwang, Deuk-Soo; Yang, Jun-Young; Kim, Sung-Jae

    2006-07-01

    We developed an effective arthroscopic pullout technique for repairing complete radial tears of the tibial attachment site of the medial meniscus posterior horn (MMPH). In our technique, the torn meniscus is reattached to the tibial plateau immediately medial or anteromedial to the posterior cruciate ligament (PCL) using two No. 2 Ethibond sutures (Ethicon, Somerville, NJ). After a complete radial tear of the tibial attachment site of the MMPH and its reparability were confirmed, using a Caspari suture loaded with a suture shuttle, one No. 2 Ethibond suture is placed through the meniscus, through the red-red zone, 3 to 5 mm medial to the torn edge of the MMPH, and the other is passed through the meniscocapsular junction 3 to 5 mm medial to the torn edge of the meniscus. Then, a tibial tunnel, 5-mm in diameter, is made from the anteromedial aspect of the proximal tibia to the previously prepared tibial plateau, immediately medial or anteromedial to the PCL, and the two No. 2 Ethibond sutures are pulled out through the tibial tunnel and then fixed to the proximal tibia using a 3.5-mm cortical screw and washer. Firm reattachment of the torn meniscus was confirmed arthroscopically.

  18. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.

    PubMed

    Khan, Irfanullah; Javed, Shahzad; Khan, Gauhar Nawaz; Aziz, Amer

    2013-03-01

    To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Case series. Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function.

  19. Effectiveness of various isometric exercises at improving bone strength in cortical regions prone to distal tibial stress fractures.

    PubMed

    Florio, C S

    2018-06-01

    A computational model was used to compare the local bone strengthening effectiveness of various isometric exercises that may reduce the likelihood of distal tibial stress fractures. The developed model predicts local endosteal and periosteal cortical accretion and resorption based on relative local and global measures of the tibial stress state and its surface variation. Using a multisegment 3-dimensional leg model, tibia shape adaptations due to 33 combinations of hip, knee, and ankle joint angles and the direction of a single or sequential series of generated isometric resultant forces were predicted. The maximum stress at a common fracture-prone region in each optimized geometry was compared under likely stress fracture-inducing midstance jogging conditions. No direct correlations were found between stress reductions over an initially uniform circular hollow cylindrical geometry under these critical design conditions and the exercise-based sets of active muscles, joint angles, or individual muscle force and local stress magnitudes. Additionally, typically favorable increases in cross-sectional geometric measures did not guarantee stress decreases at these locations. Instead, tibial stress distributions under the exercise conditions best predicted strengthening ability. Exercises producing larger anterior distal stresses created optimized tibia shapes that better resisted the high midstance jogging bending stresses. Bent leg configurations generating anteriorly directed or inferiorly directed resultant forces created favorable adaptations. None of the studied loads produced by a straight leg was significantly advantageous. These predictions and the insight gained can provide preliminary guidance in the screening and development of targeted bone strengthening techniques for those susceptible to distal tibial stress fractures. Copyright © 2018 John Wiley & Sons, Ltd.

  20. Total Knee Arthroplasty for Osteoarthritis Secondary to Fracture of the Tibial Plateau. A Prospective Matched Cohort Study.

    PubMed

    Lizaur-Utrilla, Alejandro; Collados-Maestre, Isabel; Miralles-Muñoz, Francisco A; Lopez-Prats, Fernando A

    2015-08-01

    A prospective matched cohort study was performed to compare outcomes of total knee arthroplasties (TKA) between 29 patients with posttraumatic osteoarthritis (POA) after a fracture of tibial plateau and 58 patients underwent routine TKA. Mean follow-up was 6.7 years. There were no significant differences in KSS, WOMAC, SF12 scores or range of motion. In the control group there were no complications. In the posttraumatic group, complications occurred in 4 patients (13.7%) (P=0.010) including partial patellar tendon detachment, superficial infection, skin necrosis, and knee stiffness. Only this last patient required revision for manipulation under anesthesia. Also, there was a revision for tibial aseptic loosening in each group. TKA is an effective treatment for POA after tibial plateau fracture. We recommend the prior removal of hardware, as well as tibial tubercle osteotomy when necessary. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.

    PubMed

    Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo

    2017-06-01

    High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the

  2. Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation.

    PubMed

    Tsukeoka, Tadashi; Tsuneizumi, Yoshikazu; Yoshino, Kensuke; Suzuki, Mashiko

    2018-05-01

    The aim of this study was to determine factors that contribute to bone cutting errors of conventional instrumentation for tibial resection in total knee arthroplasty (TKA) as assessed by an image-free navigation system. The hypothesis is that preoperative varus alignment is a significant contributory factor to tibial bone cutting errors. This was a prospective study of a consecutive series of 72 TKAs. The amount of the tibial first-cut errors with reference to the planned cutting plane in both coronal and sagittal planes was measured by an image-free computer navigation system. Multiple regression models were developed with the amount of tibial cutting error in the coronal and sagittal planes as dependent variables and sex, age, disease, height, body mass index, preoperative alignment, patellar height (Insall-Salvati ratio) and preoperative flexion angle as independent variables. Multiple regression analysis showed that sex (male gender) (R = 0.25 p = 0.047) and preoperative varus alignment (R = 0.42, p = 0.001) were positively associated with varus tibial cutting errors in the coronal plane. In the sagittal plane, none of the independent variables was significant. When performing TKA in varus deformity, careful confirmation of the bone cutting surface should be performed to avoid varus alignment. The results of this study suggest technical considerations that can help a surgeon achieve more accurate component placement. IV.

  3. Radiologic assessment of femoral and tibial tunnel placement based on anatomic landmarks in arthroscopic single bundle anterior cruciate ligament reconstruction.

    PubMed

    Nema, Sandeep Kumar; Balaji, Gopisankar; Akkilagunta, Sujiv; Menon, Jagdish; Poduval, Murali; Patro, Dilip

    2017-01-01

    Accurate tibial and femoral tunnel placement has a significant effect on outcomes after anterior cruciate ligament reconstruction (ACLR). Postoperative radiographs provide a reliable and valid way for the assessment of anatomical tunnel placement after ACLR. The aim of this study was to examine the radiographic location of tibial and femoral tunnels in patients who underwent arthroscopic ACLR using anatomic landmarks. Patients who underwent arthroscopic ACLR from January 2014 to March 2016 were included in this retrospective cohort study. 45 patients who underwent arthroscopic ACLR, postoperative radiographs were studied. Femoral and tibial tunnel positions on sagittal and coronal radiographic views, graft impingement, and femoral roof angle were measured. Radiological parameters were summarized as mean ± standard deviation and proportions as applicable. Interobserver agreement was measured using intraclass correlation coefficient. The position of the tibial tunnel was found to be at an average of 35.1% ± 7.4% posterior from the anterior edge of the tibia. The femoral tunnel was found at an average of 30% ± 1% anterior to the posterior femoral cortex along the Blumensaat's line. Radiographic impingement was found in 34% of the patients. The roof angle averaged 34.3° ± 4.3°. The position of the tibial tunnel was found at an average of 44.16% ± 3.98% from the medial edge of the tibial plateau. The coronal tibial tunnel angle averaged 67.5° ± 8.9°. The coronal angle of the femoral tunnel averaged 41.9° ± 8.5°. The femoral and tibial tunnel placements correlated well with anatomic landmarks except for radiographic impingement which was present in 34% of the patients.

  4. The plane strain shear fracture of the advanced high strength steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Li, E-mail: li.sun@gm.com

    2013-12-16

    The “shear fracture” which occurs at the high-curvature die radii in the sheet metal forming has been reported to remarkably limit the application of the advanced high strength steels (AHSS) in the automobile industry. However, this unusual fracture behavior generally cannot be predicted by the traditional forming limit diagram (FLD). In this research, a new experimental system was developed in order to simulate the shear fracture, especially at the plane strain state which is the most common state in the auto-industry and difficult to achieve in the lab due to sample size. Furthermore, the system has the capability to operatemore » in a strain rate range from quasi-static state to the industrial forming state. One kinds of AHSS, Quenching-Partitioning (QP) steels have been performed in this test and the results show that the limiting fracture strain is related to the bending ratio and strain rate. The experimental data support that deformation-induced heating is an important cause of “shear fracture” phenomena for AHSS: a deformation-induced quasi-heating caused by smaller bending ratio and high strain rate produce a smaller limiting plane strain and lead a “shear fracture” in the component.« less

  5. Comparison of suprapatellar and infrapatellar intramedullary nailing for tibial shaft fractures: a systematic review and meta-analysis.

    PubMed

    Yang, Liqing; Sun, Yuefeng; Li, Ge

    2018-06-14

    Optimal surgical approach for tibial shaft fractures remains controversial. We perform a meta-analysis from randomized controlled trials (RCTs) to compare the clinical efficacy and prognosis between infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. PubMed, OVID, Embase, ScienceDirect, and Web of Science were searched up to December 2017 for comparative RCTs involving infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. Primary outcomes were blood loss, visual analog scale (VAS) score, range of motion, Lysholm knee scores, and fluoroscopy times. Secondary outcomes were length of hospital stay and postoperative complications. We assessed statistical heterogeneity for each outcome with the use of a standard χ 2 test and the I 2 statistic. The meta-analysis was undertaken using Stata 14.0. Four RCTs involving 293 participants were included in our study. The present meta-analysis indicated that there were significant differences between infrapatellar and suprapatellar intramedullary nail regarding the total blood loss, VAS scores, Lysholm knee scores, and fluoroscopy times. Suprapatellar intramedullary nailing could significantly reduce total blood loss, postoperative knee pain, and fluoroscopy times compared to infrapatellar approach. Additionally, it was associated with an improved Lysholm knee scores. High-quality RCTs were still required for further investigation.

  6. Tibial Slope Strongly Influences Knee Stability After Posterior Cruciate Ligament Reconstruction: A Prospective 5- to 15-Year Follow-up.

    PubMed

    Gwinner, Clemens; Weiler, Andreas; Roider, Manoussos; Schaefer, Frederik M; Jung, Tobias M

    2017-02-01

    The reported failure rate after posterior cruciate ligament (PCL) reconstruction remains high. Previous studies have shown that the tibial slope (TS) influences sagittal plane laxity. Consequently, alterations of TS might have an effect on postoperative knee stability after PCL reconstruction. We hypothesized that flattening of TS is associated with increased posterior laxity after PCL reconstruction. Cohort study; Level of evidence 3. This study consisted of 48 patients who underwent PCL reconstruction in a single-surgeon series. Eight patients underwent an isolated PCL reconstruction, 27 patients underwent an additional posterolateral corner reconstruction, and 13 patients underwent a combined reconstruction of the PCL, anterior cruciate ligament, and posterolateral corner. Three blinded observers measured TS and the side-to-side difference (SSD) of posterior tibial translation (PTT) before and after PCL reconstruction using standardized stress radiographs. The minimum follow-up was 5 years. At a mean follow-up of 103 months (range, 65-187), the mean SSD of PTT was significantly reduced (10.9 ± 2.9 vs 4.9 ± 4.3 mm; P < .0001). The mean TS was 8.0° ± 3.7° (range, 1°-14.3°) for the operated knee and 7.9° ± 3.2° (range, 2°-15.3°) for the contralateral knee. There was a statistically significant correlation between TS and PTT ( r = -0.77 and R 2 = 0.59; P < .0001). In addition, there was a significant correlation between TS and the postoperative reduction of PTT ( r = 0.74 and R 2 = 0.55; P < .0001). Subgrouping according to the number of operated ligaments showed no significant differences regarding TS or the mean reduction of PTT. Flattening of TS is associated with a significantly higher remaining PTT as well as a lower reduction of PTT. Notably, these results are irrespective of sex and number of ligaments addressed. Thus, isolated soft tissue procedures in PCL deficiency may only incompletely address posterior knee instability in patients with

  7. Spatial-temporal three-dimensional ultrasound plane-by-plane active cavitation mapping for high-intensity focused ultrasound in free field and pulsatile flow.

    PubMed

    Ding, Ting; Hu, Hong; Bai, Chen; Guo, Shifang; Yang, Miao; Wang, Supin; Wan, Mingxi

    2016-07-01

    Cavitation plays important roles in almost all high-intensity focused ultrasound (HIFU) applications. However, current two-dimensional (2D) cavitation mapping could only provide cavitation activity in one plane. This study proposed a three-dimensional (3D) ultrasound plane-by-plane active cavitation mapping (3D-UPACM) for HIFU in free field and pulsatile flow. The acquisition of channel-domain raw radio-frequency (RF) data in 3D space was performed by sequential plane-by-plane 2D ultrafast active cavitation mapping. Between two adjacent unit locations, there was a waiting time to make cavitation nuclei distribution of the liquid back to the original state. The 3D cavitation map equivalent to the one detected at one time and over the entire volume could be reconstructed by Marching Cube algorithm. Minimum variance (MV) adaptive beamforming was combined with coherence factor (CF) weighting (MVCF) or compressive sensing (CS) method (MVCS) to process the raw RF data for improved beamforming or more rapid data processing. The feasibility of 3D-UPACM was demonstrated in tap-water and a phantom vessel with pulsatile flow. The time interval between temporal evolutions of cavitation bubble cloud could be several microseconds. MVCF beamformer had a signal-to-noise ratio (SNR) at 14.17dB higher, lateral and axial resolution at 2.88times and 1.88times, respectively, which were compared with those of B-mode active cavitation mapping. MVCS beamformer had only 14.94% time penalty of that of MVCF beamformer. This 3D-UPACM technique employs the linear array of a current ultrasound diagnosis system rather than a 2D array transducer to decrease the cost of the instrument. Moreover, although the application is limited by the requirement for a gassy fluid medium or a constant supply of new cavitation nuclei that allows replenishment of nuclei between HIFU exposures, this technique may exhibit a useful tool in 3D cavitation mapping for HIFU with high speed, precision and resolution

  8. Does a conservative tibial cut in conventional total knee arthroplasty violate the deep medial collateral ligament?

    PubMed

    Maes, Michael; Luyckx, Thomas; Bellemans, Johan

    2014-11-01

    Based on the anatomy of the deep medial collateral ligament (MCL), it was hypothesized that at least part of its cross-sectional insertion area is jeopardized while performing a standard tibial cut in conventional total knee arthroplasty (TKA). The aim of this study was to determine whether it is anatomically possible to preserve the tibial deep MCL insertion during conventional TKA. Thirty-three unpaired cadaveric knee specimens were used for this study. Knees with severe varus/valgus deformity or damage to the medial structures of the knee were excluded. In the first part of the study, the dimensions of the tibial insertion of the deep MCL and its relationship to the joint line were recorded. Next, the cross-sectional area of the deep MCL insertion was determined using calibrated digital photographic analysis. In the second part, the effect of a standard 9-mm 3° sloped tibial cut on the structural integrity of the deep MCL cross-sectional insertion area was determined using conventional instrumentation. The proximal border of the deep MCL insertion site on the tibia was located on average 4.7 ± 1.2 mm distally to the joint line. After performing a standard 9-mm 3° sloped tibial cut, on average 54% of the deep MCL insertion area was resected. In 29% of the cases, the deep MCL insertion area was completely excised. The deep MCL cannot routinely be preserved in conventional TKA. The deep MCL insertion is at risk and may be jeopardized in case of a tibial cut 9 mm below the native joint line. As the deep MCL is a distinct medial stabilizer and plays an important role in rotational stability, this may have implications in future designs of both unicondylar and total knee arthroplasty, but further research is necessary.

  9. Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing.

    PubMed

    Galbraith, John G; Daly, Charles J; Harty, James A; Dailey, Hannah L

    2016-10-01

    For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. In-plane and out-of-plane motions of the human tympanic membrane

    PubMed Central

    Khaleghi, Morteza; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J.

    2016-01-01

    Computer-controlled digital holographic techniques are developed and used to measure shape and four-dimensional nano-scale displacements of the surface of the tympanic membrane (TM) in cadaveric human ears in response to tonal sounds. The combination of these measurements (shape and sound-induced motions) allows the calculation of the out-of-plane (perpendicular to the surface) and in-plane (tangential) motion components at over 1 000 000 points on the TM surface with a high-degree of accuracy and sensitivity. A general conclusion is that the in-plane motion components are 10–20 dB smaller than the out-of-plane motions. These conditions are most often compromised with higher-frequency sound stimuli where the overall displacements are smaller, or the spatial density of holographic fringes is higher, both of which increase the uncertainty of the measurements. The results are consistent with the TM acting as a Kirchhoff–Love's thin shell dominated by out-of-plane motion with little in-plane motion, at least with stimulus frequencies up to 8 kHz. PMID:26827009

  11. Management of Open Tibial Shaft Fractures: Does the Timing of Surgery Affect Outcomes?

    PubMed

    Duyos, Oscar A; Beaton-Comulada, David; Davila-Parrilla, Ariel; Perez-Lopez, Jose Carlos; Ortiz, Krystal; Foy-Parrilla, Christian; Lopez-Gonzalez, Francisco

    2017-03-01

    Open tibial shaft fractures require emergent care. Treatment with intravenous antibiotics and fracture débridement within 6 to 24 hours is recommended. Few studies have examined outcomes when surgical treatment is performed >24 hours after occurrence of the fracture. This retrospective study included 227 patients aged ≥18 years with isolated open tibial shaft fractures in whom the time to initial débridement was >24 hours. The statistical analysis was based on time from injury to surgical débridement, Gustilo-Anderson classification, method of fixation, union status, and infection status. Fractures débrided within 24 to 48 hours and 48 to 96 hours after injury did not show a statistically significant difference in terms of infection rates (P = 0.984). External fixation showed significantly greater infection rates (P = 0.044) and nonunion rates (P = 0.001) compared with intramedullary nailing. Open tibial shaft fractures should be débrided within 24 hours after injury. Our data indicate that after the 24-hour period and up to 4 days, the risk of infection remains relatively constant independent of the time to débridement. Patients treated with external fixation had more complications than did patients treated with other methods of fixation. Primary reamed intramedullary nailing appears to be a reasonable option for the management of Gustilo-Anderson types 1 and 2 open tibial shaft fractures. Level III retrospective study.

  12. Out-of-plane chiral domain wall spin-structures in ultrathin in-plane magnets

    DOE PAGES

    Chen, Gong; Kang, Sang Pyo; Ophus, Colin; ...

    2017-05-19

    Chiral spin textures in ultrathin films, such as skyrmions or chiral domain walls, are believed to offer large performance advantages in the development of novel spintronics technologies. While in-plane magnetized films have been studied extensively as media for current- and field-driven domain wall dynamics with applications in memory or logic devices, the stabilization of chiral spin textures in in-plane magnetized films has remained rare. Here we report a phase of spin structures in an in-plane magnetized ultrathin film system where out-of-plane spin orientations within domain walls are stable. Moreover, while domain walls in in-plane films are generally expected to bemore » non-chiral, we show that right-handed spin rotations are strongly favoured in this system, due to the presence of the interfacial Dzyaloshinskii-Moriya interaction. These results constitute a platform to explore unconventional spin dynamics and topological phenomena that may enable high-performance in-plane spin-orbitronics devices.« less

  13. Radiologic assessment of femoral and tibial tunnel placement based on anatomic landmarks in arthroscopic single bundle anterior cruciate ligament reconstruction

    PubMed Central

    Nema, Sandeep Kumar; Balaji, Gopisankar; Akkilagunta, Sujiv; Menon, Jagdish; Poduval, Murali; Patro, Dilip

    2017-01-01

    Background: Accurate tibial and femoral tunnel placement has a significant effect on outcomes after anterior cruciate ligament reconstruction (ACLR). Postoperative radiographs provide a reliable and valid way for the assessment of anatomical tunnel placement after ACLR. The aim of this study was to examine the radiographic location of tibial and femoral tunnels in patients who underwent arthroscopic ACLR using anatomic landmarks. Patients who underwent arthroscopic ACLR from January 2014 to March 2016 were included in this retrospective cohort study. Materials and Methods: 45 patients who underwent arthroscopic ACLR, postoperative radiographs were studied. Femoral and tibial tunnel positions on sagittal and coronal radiographic views, graft impingement, and femoral roof angle were measured. Radiological parameters were summarized as mean ± standard deviation and proportions as applicable. Interobserver agreement was measured using intraclass correlation coefficient. Results: The position of the tibial tunnel was found to be at an average of 35.1% ± 7.4% posterior from the anterior edge of the tibia. The femoral tunnel was found at an average of 30% ± 1% anterior to the posterior femoral cortex along the Blumensaat's line. Radiographic impingement was found in 34% of the patients. The roof angle averaged 34.3° ± 4.3°. The position of the tibial tunnel was found at an average of 44.16% ± 3.98% from the medial edge of the tibial plateau. The coronal tibial tunnel angle averaged 67.5° ± 8.9°. The coronal angle of the femoral tunnel averaged 41.9° ± 8.5°. Conclusions: The femoral and tibial tunnel placements correlated well with anatomic landmarks except for radiographic impingement which was present in 34% of the patients. PMID:28566780

  14. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    PubMed

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  15. Highly precise acoustic calibration method of ring-shaped ultrasound transducer array for plane-wave-based ultrasound tomography

    NASA Astrophysics Data System (ADS)

    Terada, Takahide; Yamanaka, Kazuhiro; Suzuki, Atsuro; Tsubota, Yushi; Wu, Wenjing; Kawabata, Ken-ichi

    2017-07-01

    Ultrasound computed tomography (USCT) is promising for a non-invasive, painless, operator-independent and quantitative system for breast-cancer screening. Assembly error, production tolerance, and aging-degradation variations of the hardwire components, particularly of plane-wave-based USCT systems, may hamper cost effectiveness, precise imaging, and robust operation. The plane wave is transmitted from a ring-shaped transducer array for receiving the signal at a high signal-to-noise-ratio and fast aperture synthesis. There are four signal-delay components: response delays in the transmitters and receivers and propagation delays depending on the positions of the transducer elements and their directivity. We developed a highly precise calibration method for calibrating these delay components and evaluated it with our prototype plane-wave-based USCT system. Our calibration method was found to be effective in reducing delay errors. Gaps and curves were eliminated from the plane wave, and echo images of wires were sharpened in the entire imaging area.

  16. Fixator-assisted medial tibial plateau elevation to treat severe Blount's disease: outcomes at maturity.

    PubMed

    Fitoussi, F; Ilharreborde, B; Lefevre, Y; Souchet, P; Presedo, A; Mazda, K; Penneçot, G F

    2011-04-01

    Severe forms of Blount's disease may be associated with medial tibial plateau (MTP) depression. Management should then take account of joint congruence, laxity, limb axis, torsional abnomality, leg length discrepancy (LLD) and eventual recurrence history. Eight knees (six patients) were managed in a single step comprising MTP elevation osteotomy, lateral epiphysiodesis and proximal tibia osteotomy to correct varus and rotational deformity. Fixation was achieved using an Ilizarov external fixator. Mean age was 10.5 years. Mean hip-knee-ankle (HKA) angle was 151°; distal femoral varus, 94°; metaphyseal-diaphyseal angle (MDA), 27°; and angle of depression of the medial tibial plateau (ADMTP), 42°. Predicted residual proximal tibial growth was 2.6 cm. At a mean 48 months' follow-up, results were good in six cases, medium in one and poor (due to incomplete lateral epiphysiodesis) in one. Mean lateral tibial torsion was 9° and final LLD 11 mm. Weight-bearing was resumed at 2 months, and the fixator was removed at 5.5 months postoperatively. At end of follow-up, mean HKA angle was 179.6°, MDA 7.3° and ADMTP 5.4°. This technically demanding procedure gave satisfactory results in terms of axes and congruence; longer term assessment remains needed. Level IV. Retrospective study. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  17. Medial tibial stress syndrome in high school cross-country runners: incidence and risk factors.

    PubMed

    Plisky, Melody S; Rauh, Mitchell J; Heiderscheit, Bryan; Underwood, Frank B; Tank, Robert T

    2007-02-01

    Prospective cohort. To determine (1) the cumulative seasonal incidence and overall injury rate of medial tibial stress syndrome (MTSS) and (2) risk factors for MTSS with a primary focus on the relationship between navicular drop values and MTSS in high school cross-country runners. MTSS is a common injury among runners. However, few studies have reported the injury rate and risk factors for MTSS among adolescent runners. Data collected included measurement of bilateral navicular drop and foot length, and a baseline questionnaire regarding the runner's height, body mass, previous running injury, running experience, and orthotic or tape use. Runners were followed during the season to determine athletic exposures (AEs) and occurrence of MTSS. The overall injury rate for MTSS was 2.8/1000 AEs. Although not statistically different, girls had a higher rate (4.3/1000 AEs) than boys (1.7/1000 AEs) (P = .11). Logistic regression modeling indicated that only gender and body mass index (BMI) were significantly associated with the occurrence of MTSS. However, when controlled for orthotic use, only BMI was associated with risk of MTSS. No significant associations were found between MTSS and navicular drop or foot length. Our findings suggest that navicular drop may not be an appropriate measure to identify runners who may develop MTSS during a cross-country season; thus, additional studies are needed to identify appropriate preseason screening tools.

  18. Surgical treatment of a proximal diaphyseal tibial deformity associated with partial caudal and cranial cruciate ligament deficiency and patella baja.

    PubMed

    Vincenti, S; Knell, S; Pozzi, A

    2017-04-01

    Caudal cruciate ligament injury can be a complication following tibial plateau leveling osteotomy (TPLO) (Slocum und Slocum, 1993) especially if the post-operative Tibial Plateau Angle (TPA) is less than 5 degree. We describe a case of negative TPA associated with partial cranial and caudal ligament rupture treated with a center of rotation of angulation (CORA) based cranial tibial opening wedge osteotomy and tibial tuberosity transposition. A 13 kg, mixed breed dog was presented for right pelvic limb lameness. Radiographically a bilateral patella baja and a malformed tibia tuberosity along with a bilateral TPA of -8 degree were detected. Arthroscopically a partial rupture of the cranial and caudal cruciate ligaments were found. A cranial tibial opening wedge osteotomy of 23 degree and a fibular ostectomy were performed. The osteotomy was fixed with a 8 holes ALPS 9 (KYON, Switzerland) and a 3-holes 2.0mm UniLock plate (Synthes, Switzerland). Then a proximal tibial tuberosity transposition of 10mm was performed and fixed with a pin and tension band construct. The postoperative TPA was 15 degree. The radiographic controls at 6, 10 weeks, 6 months and 1 year after surgery revealed an unchanged position of the implants and progressive healing of the osteotomies. At the 6 and 12 months recheck evaluation the dog had no evidence of lameness or stifle pain and radiographs revealed complete healing of the osteotomy site and no implant failure. The diaphyseal CORA based osteotomy allowed accurate correction of a proximal tibial deformity associated with negative TPA.

  19. High Sensitivity Long-Wavelength Infrared QWIP Focal Plane Array Based Instrument for Remote Sensing of Icy Satellites

    NASA Technical Reports Server (NTRS)

    Gunapala, S.; Bandara, S.; Ivanov, A.

    2003-01-01

    GaAs based Quantum Well Infrared Photodetector (QWIP) technology has shown remarkable success in advancing low cost, highly uniform, high-operability, large format multi-color focal plane arrays. QWIPs afford greater flexibility than the usual extrinsically doped semiconductor IR detectors. The wavelength of the peak response and cutoff can be continuously tailored over a range wide enough to enable light detection at any wavelength range between 6 and 20 micron. The spectral band-width of these detectors can be tuned from narrow (Deltalambda/lambda is approximately 10%) to wide (Deltalambda/lambda is approximately 40%) allowing various applications. Furthermore, QWIPs offer low cost per pixel and highly uniform large format focal plane arrays due to mature GaAs/AlGaAs growth and processing technologies. The other advantages of GaAs/AlGaAs based QWIPS are higher yield, lower l/f noise and radiation hardness (1.5 Mrad). In this presentation, we will discuss our recent demonstrations of 640x512 pixel narrow-band, broad-band, multi-band focal plane arrays, and the current status of the development of 1024x1024 pixel long-wavelength infrared QWIP focal plane arrays.

  20. Lateralization of the Tibial Tubercle in Recurrent Patellar Dislocation: Verification Using Multiple Methods to Evaluate the Tibial Tubercle.

    PubMed

    Tensho, Keiji; Shimodaira, Hiroki; Akaoka, Yusuke; Koyama, Suguru; Hatanaka, Daisuke; Ikegami, Shota; Kato, Hiroyuki; Saito, Naoto

    2018-05-02

    The tibial tubercle deviation associated with recurrent patellar dislocation (RPD) has not been studied sufficiently. New methods of evaluation were used to verify the extent of tubercle deviation in a group with patellar dislocation compared with that in a control group, the frequency of patients who demonstrated a cutoff value indicating that tubercle transfer was warranted on the basis of the control group distribution, and the validity of these methods of evaluation for diagnosing RPD. Sixty-six patients with a history of patellar dislocation (single in 19 [SPD group] and recurrent in 47 [RPD group]) and 66 age and sex-matched controls were analyzed with the use of computed tomography (CT). The tibial tubercle-posterior cruciate ligament (TT-PCL) distance, TT-PCL ratio, and tibial tubercle lateralization (TTL) in the SPD and RPD groups were compared with those in the control group. Cutoff values to warrant 10 mm of transfer were based on either the minimum or -2SD (2 standard deviations below the mean) value in the control group, and the prevalences of patients in the RPD group with measurements above these cutoff values were calculated. The area under the curve (AUC) in receiver operating characteristic (ROC) curve analysis was used to assess the effectiveness of the measurements as predictors of RPD. The mean TT-PCL distance, TT-PCL ratio, and TTL were all significantly greater in the RPD group than in the control group. The numbers of patients in the RPD group who satisfied the cutoff criteria when they were based on the minimum TT-PCL distance, TT-PCL ratio, and TTL in the control group were 11 (23%), 7 (15%), and 6 (13%), respectively. When the cutoff values were based on the -2SD values in the control group, the numbers of patients were 8 (17%), 6 (13%), and 0, respectively. The AUC of the ROC curve for TT-PCL distance, TT-PCL ratio, and TTL was 0.66, 0.72, and 0.72, respectively. The extent of TTL in the RPD group was not substantial, and the percentages

  1. Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture.

    PubMed

    Zhang, Wei; Luo, Cong-Feng; Putnis, Sven; Sun, Hui; Zeng, Zhi-Min; Zeng, Bing-Fang

    2012-03-01

    The posterolateral shearing tibial plateau fracture is uncommon in the literature, however with the increased usage of computer tomography (CT), the incidence of these fractures is no longer as low as previously thought. Few studies have concentrated on this fracture, least of all using a biomechanical model. The purpose of this study was to compare and analyse the biomechanical characteristics of four different types of internal fixation to stabilise the posterolateral shearing tibial plateau fracture. Forty synthetic tibiae (Synbone, right) simulated the posterolateral shearing fracture models and these were randomly assigned into four groups; Group A was fixed with two anterolateral lag screws, Group B with an anteromedial Limited Contact Dynamic Compression Plate (LC-DCP), Group C with a lateral locking plate, and Group D with a posterolateral buttress plate. Vertical displacement of the posterolateral fragment was measured using three different strengths of axial loading force, and finally loaded until fixation failure. It was concluded that the posterolateral buttress plate is biomechanically the strongest fixation method for the posterolateral shearing tibial plateau fracture. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. VAST PLANES OF SATELLITES IN A HIGH-RESOLUTION SIMULATION OF THE LOCAL GROUP: COMPARISON TO ANDROMEDA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillet, N.; Ocvirk, P.; Aubert, D.

    2015-02-10

    We search for vast planes of satellites (VPoS) in a high-resolution simulation of the Local Group performed by the CLUES project, which improves significantly the resolution of previous similar studies. We use a simple method for detecting planar configurations of satellites, and validate it on the known plane of M31. We implement a range of prescriptions for modeling the satellite populations, roughly reproducing the variety of recipes used in the literature, and investigate the occurrence and properties of planar structures in these populations. The structure of the simulated satellite systems is strongly non-random and contains planes of satellites, predominantly co-rotating,more » with, in some cases, sizes comparable to the plane observed in M31 by Ibata et al. However, the latter is slightly richer in satellites, slightly thinner, and has stronger co-rotation, which makes it stand out as overall more exceptional than the simulated planes, when compared to a random population. Although the simulated planes we find are generally dominated by one real structure forming its backbone, they are also partly fortuitous and are thus not kinematically coherent structures as a whole. Provided that the simulated and observed planes of satellites are indeed of the same nature, our results suggest that the VPoS of M31 is not a coherent disk and that one-third to one-half of its satellites must have large proper motions perpendicular to the plane.« less

  3. Differences in Medial and Lateral Posterior Tibial Slope: An Osteological Review of 1090 Tibiae Comparing Age, Sex, and Race.

    PubMed

    Weinberg, Douglas S; Williamson, Drew F K; Gebhart, Jeremy J; Knapik, Derrick M; Voos, James E

    2017-01-01

    Injuries to the anterior cruciate ligament (ACL) are common, and a number of knee morphological variables have been identified as risk factors for an ACL injury, including the posterior tibial slope (TS). However, limited data exist regarding innate population differences in the TS. To (1) establish normative values for the medial and lateral posterior TS; (2) determine what differences exist between ages, sexes, and races; and (3) determine how internal or external tibial rotation (as occurs during sagittal knee motion) influences the stereotactic perception of the TS. Cross-sectional study; Level of evidence, 3. A total of 545 cadaveric specimens (1090 tibiae) were obtained from the Hamann-Todd osteological collection. Specimens were leveled in the coronal, sagittal, and axial planes using a digital laser. Virtual representations of each bone were created with a 3-dimensional digitizer apparatus. The TS of the medial and lateral tibial plateaus were measured using techniques adapted from previous radiographic protocols. Medial and lateral TS were then again measured on 200 tibiae that were internally and externally rotated by 10° (axially). The mean (±SD) medial TS was 6.9° ± 3.7° posterior, which was greater than the mean lateral TS of 4.7° ± 3.6° posterior ( P < .001). Neither the medial nor lateral TS changed with age. Women had a greater mean TS compared with men on both the medial (7.5° ± 3.8° vs 6.8° ± 3.7°, respectively; P = .03) and lateral (5.2° ± 3.5° vs 4.6° ± 3.5°, respectively; P = .04) sides. Black specimens had a greater mean medial TS (8.7° ± 3.6° vs 5.8° ± 3.3°, respectively; P < .001) and lateral TS (5.9° ± 3.3° vs 3.8° ± 3.5°, respectively; P < .001) compared with white specimens. Axial rotation was shown to increase the perception of the medial and lateral TS ( P < .001). The medial TS was shown to be greater than the lateral TS. Important sex- and race-based differences exist in the TS. This study also

  4. Arthroscopic evaluation of soft tissue injuries in tibial plateau fractures: retrospective analysis of 98 cases.

    PubMed

    Abdel-Hamid, Mohamed Zaki; Chang, Chung-Hsun; Chan, Yi-Sheng; Lo, Yang-Pin; Huang, Jau-Wen; Hsu, Kuo-Yao; Wang, Ching-Jen

    2006-06-01

    This investigation arthroscopically assesses the frequency of soft tissue injury in tibial plateau fracture according to the severity of fracture patterns. We hypothesized that use of arthroscopy to evaluate soft tissue injury in tibial plateau fractures would reveal a greater number of associated injuries than have previously been reported. From March 1996 to December 2003, 98 patients with closed tibial plateau fractures were treated with arthroscopically assisted reduction and osteosynthesis, with precise diagnosis and management of associated soft tissue injuries. Arthroscopic findings for associated soft tissue injuries were recorded, and the relationship between fracture type and soft tissue injury was then analyzed. The frequency of associated soft tissue injury in this series was 71% (70 of 98). The menisci were injured in 57% of subjects (56 in 98), the anterior cruciate ligament (ACL) in 25% (24 of 98), the posterior cruciate ligament (PCL) in 5% (5 of 98), the lateral collateral ligament (LCL) in 3% (3 of 98), the medial collateral ligament (MCL) in 3% (3 of 98), and the peroneal nerve in 1% (1 of 98); none of the 98 patients exhibited injury to the arteries. No significant association was noted between fracture type and incidence of meniscus, PCL, LCL, MCL, artery, and nerve injury. However, significantly higher injury rates for the ACL were observed in type IV and VI fractures. Soft tissue injury was associated with all types of tibial plateau fracture. Menisci (peripheral tear) and ACL (bony avulsion) were the most commonly injured sites. A variety of soft tissue injuries are common with tibial plateau fracture; these can be diagnosed with the use of an arthroscope. Level III, diagnostic study.

  5. Long-term anabolic effects of prostaglandin-E2 on tibial diaphyseal bone in male rats

    NASA Technical Reports Server (NTRS)

    Jee, Webster S. S.; Ke, Hua Zhu; Li, Xiao Jian

    1991-01-01

    The effects of long-term prostaglandin E2 (PGE2) on tibial diaphyseal bone were studied in 7-month-old male Sprague-Dawley rats given daily subcutaneous injections of 0, 1, 3 and 6 mg PGE2/kg/day for 60, 120 and 180 days. The tibial shaft was measured by single photon absorptiometry and dynamic histomorphometric analyses were performed on double-fluorescent labeled undecalcified tibial diaphyseal bone samples. Exogenous PGE2 administration produced the following transient changes in a dose-response manner between zero and 60 days: (1) increased bone width and mineral density; (2) increased total tissue and total bone areas; (3) decreased marrow area; (4) increased periosteal and corticoendosteal lamellar bone formation; (5) activated corticoendosteal lamellar and woven trabecular bone formation; and (6) activated intracortical bone remodeling. A new steady-state of increased tibial diaphyseal bone mass and elevated bone activities were observed from day 60 onward. The elevated bone mass level attained after 60 days of PGE2 treatment was maintained at 120 and 180 days. These observations indicate that the powerful anabolic effects of PGE2 will increase both periosteal and corticoendosteal bone mass and sustain the transient increase in bone mass with continuous daily administration of PGE2.

  6. Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years.

    PubMed

    Carlsson, Ake; Björkman, Anders; Besjakov, Jack; Onsten, Ingemar

    2005-06-01

    The question whether the tibial component of a total knee arthroplasty should be fixed to bone with or without bone cement has not yet been definitely answered. We studied movements between the tibial component and bone by radiostereometry (RSA) in total knee replacement (TKR) for 3 different types of fixation: cemented fixation (C-F), uncemented porous fixation (UC-F) and uncemented porous hydroxyapatite fixation (UCHA-F). 116 patients with osteoarthrosis, who had 146 TKRs, were included in 2 randomized series. The first series included 86 unilateral TKRs stratified into 1 of the 3 types of fixation. The second series included 30 patients who had simultaneous bilateral TKR surgery, and who were stratified into 3 subgroups of pairwise comparisons of the 3 types of fixation. After 5 years 2 knees had been revised, neither of which were due to loosening. 1 UCHA-F knee in the unilateral series showed a large and continuous migration and a poor clinical result, and is a pending failure. The C-F knees rotated and migrated less than UC-F and UCHA-F knees over 5 years. UCHA-F migrated less than UC-F after 1 year. Cementing of the tibial component offers more stable bone-implant contact for 5 years compared to uncemented fixation. When using uncemented components, however, there is evidence that augmenting a porous surface with hydroxyapatite may mean less motion between implant and bone after the initial postoperative year.

  7. [Tibiotalocalcaneal arthrodesis using a retrograde nail locked in the sagittal plane].

    PubMed

    Veselý, R; Procházka, V; Visna, P; Valentová, J; Savolt, J

    2008-04-01

    To evaluate our experience with the use of a retrograde nail locked in the sagittal plane for tibiotalocalcaneal arthrodesis indicated in severe post-traumatic arthritis of the ankle. Twenty patients, 16 men and four women at an average age of 58.7 years (range, 23 to 72) were evaluated. All patients had severe post-traumatic changes in the talocrural and talocalcaneal joints. Five patients also had an equinus deformity. In two patients arthrodesis followed the treatment of purulent arthritis of the talocrural joint. A local fasciocutaneous flap was used for soft tissue reconstruction in three patients. All patients were operated on using the standard surgical technique. METHODS With the patient in a supine position, reamed by hand with the use of a driving rod, a straight retrograde AAN Orthofix nail was inserted through the heel bone and talus into the distal tibia and locked in these bones in the sagittal plane. No complications such as injury to the neurovascular plexus or pseudoarthrosis were recorded. Four patients showed a reaction to the proximal locking screw on the proximal tibial surface, which was treated by earlier screw removal under topical anaesthesia. Due to infectious complications, the nail had to be removed prematurely in one patient. The average Foot Function Index was 12 points (range, 10 to 15) and the average ankle-hindfoot score was 67.6 points (range, 59 to 84). Thirteen patients (65 %) were not limited in their daily activities or recreational sports, six (30 %) experienced pain in sports but not daily activities and one patient (5 %) reported pain even when walking. All fusions healed in the correct position within 18 weeks. Tibiotalocalcaneal arthrodesis is not a frequent surgical procedure in either trauma surgery or orthopaedics. For this complicated procedure, rather than intramedullary nails, internal fixation with screws or plates or external fixation are preferred. The high rate of bony healing can be explained by maintenance of

  8. Etiologic factors in the development of medial tibial stress syndrome: a review of the literature.

    PubMed

    Tweed, Jo L; Avil, Steven J; Campbell, Jackie A; Barnes, Mike R

    2008-01-01

    Medial tibial stress syndrome is a type of exercise-induced leg pain that is common in recreational and competitive athletes. Although various studies have attempted to find the exact pathogenesis of this common condition, it remains unknown. Various theories in literature from 1976 to 2006 were reviewed using key words. Until recently, inflammation of the periosteum due to excessive traction was thought to be the most likely cause of medial tibial stress syndrome. This periostitis has been hypothesized by some authors to be caused by the tearing away of the muscle fibers at the muscle-bone interface, although there are several suggestions as to which, if any, muscle is responsible. Recent studies have supported the view that medial tibial stress syndrome is not an inflammatory process of the periosteum but instead a stress reaction of bone that has become painful.

  9. Clinical and radiographic outcomes of medial open-wedge high tibial osteotomy with Anthony-K plate: prospective minimum five year follow-up data.

    PubMed

    Altay, Mehmet Akif; Ertürk, Cemil; Altay, Nuray; Mercan, Ahmet Şükrü; Sipahioğlu, Serkan; Kalender, Ali Murat; Işıkan, Uğur Erdem

    2016-07-01

    The purpose of this study was to prospectively evaluate the clinical and radiographic outcomes, and complication rates, after a minimum of five years of follow-up after medial open wedge high tibial osteotomy (MOWHTO) using an Anthony-K plate. MOWHTO was performed on 35 knees of 34 consecutive patients. A visual analogue scale (VAS), and Western Ontario and McMaster University Osteoarthritis (WOMAC) and Lysholm scores, were used in clinical evaluation. Upon radiographic assessment, alignment was expressed as the femorotibial angle (FTA). The posterior tibial slope (PTS) and the Insall-Salvati Index (ISI) were also measured. VAS, WOMAC, and Lysholm scores improved significantly upon follow-up (p < 0.001 for all). The overall mean FTA was 4.68 ± 4.39° varus pre-operatively; at the last post-operative follow-up, the value was 8.43 ± 2.02° valgus. The mean correction angle was 13.1 ± 2.7°. A significant increase in PTS was evident (p < 0.01), as was a significant decrease in the ISI (p < 0.01). The overall complication rate was 8.6 %. The Anthony-K plate affords accurate correction, initially stabilises the osteotomy after surgery, and maintains such stability until the osteotomy gap is completely healed, without correction loss. The plate survival rate was 97.2 % after a minimum of five years of follow-up. The plate increased the PTS, as do other medial osteotomy fixation plates.

  10. ß-TCP bone substitutes in tibial plateau depression fractures.

    PubMed

    Rolvien, Tim; Barvencik, Florian; Klatte, Till Orla; Busse, Björn; Hahn, Michael; Rueger, Johannes Maria; Rupprecht, Martin

    2017-10-01

    The use of beta-tricalciumphospate (ß-TCP, Cerasorb®) ceramics as an alternative for autologous bone-grafting has been outlined previously, however with no study focusing on both clinical and histological outcomes of ß-TCP application in patients with multi-fragment tibial plateau fractures. The aim of this study was to analyze the long-term results of ß-TCP in patients with tibial plateau fractures. 52 patients were included in this study. All patients underwent open surgery with ß-TCP block or granulate application. After a mean follow-up of 36months (14-64months), the patients were reviewed. Radiography and computed-tomography were performed, while the Rasmussen score was obtained for clinical outcome. Furthermore, seven patients underwent biopsy during hardware removal, which was subsequently analyzed by histology and backscattered electron microscopy (BSEM). An excellent reduction with two millimeters or less of residual incongruity was achieved in 83% of the patients. At follow-up, no further changes occurred and no nonunions were observed. Functional outcome was good to excellent in 82%. Four patients underwent revision surgery due to reasons unrelated to the bone substitute material. Histologic analyses indicated that new bone was built around the ß-TCP-grafts, however a complete resorption of ß-TCP was not observed. ß-TCP combined with internal fixation represents an effective and safe treatment of tibial plateau depression fractures with good functional recovery. While its osteoconductivity seems to be successful, the biological degradation and replacement of ß-TCP is less pronounced in humans than previous animal studies have indicated. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. An information-theoretic approach to designing the plane spacing for multifocal plane microscopy

    PubMed Central

    Tahmasbi, Amir; Ram, Sripad; Chao, Jerry; Abraham, Anish V.; Ward, E. Sally; Ober, Raimund J.

    2015-01-01

    Multifocal plane microscopy (MUM) is a 3D imaging modality which enables the localization and tracking of single molecules at high spatial and temporal resolution by simultaneously imaging distinct focal planes within the sample. MUM overcomes the depth discrimination problem of conventional microscopy and allows high accuracy localization of a single molecule in 3D along the z-axis. An important question in the design of MUM experiments concerns the appropriate number of focal planes and their spacings to achieve the best possible 3D localization accuracy along the z-axis. Ideally, it is desired to obtain a 3D localization accuracy that is uniform over a large depth and has small numerical values, which guarantee that the single molecule is continuously detectable. Here, we address this concern by developing a plane spacing design strategy based on the Fisher information. In particular, we analyze the Fisher information matrix for the 3D localization problem along the z-axis and propose spacing scenarios termed the strong coupling and the weak coupling spacings, which provide appropriate 3D localization accuracies. Using these spacing scenarios, we investigate the detectability of the single molecule along the z-axis and study the effect of changing the number of focal planes on the 3D localization accuracy. We further review a software module we recently introduced, the MUMDesignTool, that helps to design the plane spacings for a MUM setup. PMID:26113764

  12. [Effects of posterior tibial slope on non-contact anterior cruciate ligament rupture and stability of anterior cruciate ligament rupture knee].

    PubMed

    Yue, De-bo; E, Sen; Wang, Bai-liang; Wang, Wei-guo; Guo, Wan-shou; Zhang, Qi-dong

    2013-05-07

    To retrospectively explore the correlation between anterior cruciate ligament (ACL)-ruptured knees, stability of ACL-rupture knee and posterior tibial slope (PTS). From January 2008 to October 2012, 150 knees with ACL rupture underwent arthroscopic surgery for ACL reconstruction. A control group was established for subjects undergoing arthroscopic surgery without ACL rupture during the same period. PTS was measured on a digitalized lateral radiograph. Lachman and mechanized pivot shift tests were performed for assessing the stability of knee. There was significant difference (P = 0.007) in PTS angle between the patients with ACL rupture (9.5 ± 2.2 degrees) and the control group (6.6 ± 1.8 degrees). Only among females, increased slope of tibial plateau had effect on the Lachman test. There was a higher positive rate of pivot shift test in patients of increased posterior slope in the ACL rupture group. Increased posterior tibial slope (>6.6) appears to contribute to non-contact ACL injuries in females. And the changes of tibial slope have no effect upon the Lachman test. However, large changes in tibial slope affect pivot shift.

  13. Atypical presentation of popliteal artery entrapment syndrome: involvement of the anterior tibial artery.

    PubMed

    Bou, Steven; Day, Carly

    2014-11-01

    Popliteal artery entrapment syndrome (PAES) is a rare condition that should be suspected in a young patient with exertional lower extremity pain. We report the case of an 18-year-old female volleyball player with bilateral exertional lower extremity pain who had been previously diagnosed with tendinitis and periostitis. Diagnostic studies showed entrapment of the left popliteal artery and the left anterior tibial artery. To our knowledge, there has only been 1 previous report of anterior tibial artery involvement in PAES. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  14. Effects of directly autotransplanted tibial bone marrow aspirates on bone regeneration and osseointegration of dental implants.

    PubMed

    Payer, Michael; Lohberger, Birgit; Strunk, Dirk; Reich, Karoline M; Acham, Stephan; Jakse, Norbert

    2014-04-01

    Aim of the pilot trial was to evaluate applicability and effects of directly autotransplanted tibial bone marrow (BM) aspirates on the incorporation of porous bovine bone mineral in a sinus lift model and on the osseointegration of dental implants. Six edentulous patients with bilaterally severely resorbed maxillae requiring sinus augmentation and implant treatment were included. During surgery, tibial BM was harvested and added to bone substitute material (Bio-Oss(®) ) at the randomly selected test site. At control sites, augmentation was performed with Bio-Oss(®) alone. The cellular content of each BM aspirate was checked for multipotency and surface antigen expression as quality control. Histomorphometric analysis of biopsies from the augmented sites after 3 and 6 months (during implantation) was used to evaluate effects on bone regeneration. Osseointegration of implants was evaluated with Periotest(®) and radiographic means. Multipotent cellular content in tibial BM aspirates was comparable to that in punctures from the iliac crest. No significant difference in amount of new bone formation and the integration of bone substitute particles was detected histomorphometrically. Periotest(®) values and radiographs showed successful osseointegration of inserted implants at all sites. Directly autotransplanted tibial BM aspirates did not show beneficial regenerative effects in the small study population (N = 6) of the present pilot trial. However, the proximal tibia proved to be a potential donor site for small quantities of BM. Future trials should clarify whether concentration of tibial BM aspirates could effect higher regenerative potency. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Incidence of complications associated with tibial tuberosity advancement in Boxer dogs.

    PubMed

    de Lima Dantas, Brigite; Sul, Rui; Parkin, Tim; Calvo, Ignacio

    2016-01-01

    To retrospectively review and describe the incidence of complications associated with tibial tuberosity advancement (TTA) surgical procedures in a group of Boxer dogs (n = 36 stifles) and compare the data with a non-Boxer control population (n = 271 stifles). Retrospective analysis of medical records to identify all dogs that underwent TTA surgery due to cranial cruciate ligament disease. These records were categorized into two groups: Boxer dogs and non-Boxer dogs (controls - all other breeds). Of the 307 stifles included, 69 complications were reported in 58 joints. The complication rate differed significantly for Boxer dogs (16/36 stifles) and non-Boxer dogs (42/271 stifles), corresponding to an odds ratio of 5.8 (confidence interval: 1.96-17.02; p-value <0.001). Boxer dogs were more likely to undergo revision surgery and to develop multiple complications. The incidence of tibial tuberosity fractures requiring surgical repair (2/36 versus 1/271) and incisional infections requiring antibiotic treatment (three in each group) was significantly higher in the Boxer group. Boxer dogs had more major and multiple complications after TTA surgery than the control non-Boxer group; these complications included higher rates of revision surgery, tibial tuberosity fractures requiring stabilization, and infection related complications. The pertinence and value of breed-specific recommendations for cranial cruciate ligament disease appears to be a subject worthy of further investigation.

  16. Os tibiale externum or sesamoid in the tendon of tibialis posterior.

    PubMed

    Bareither, D J; Muehleman, C M; Feldman, N J

    1995-01-01

    From a total of 165 foot and lower leg cadaveric specimens, 38 specimens were selected by palpation of the region of the tuberosity of the navicular for the possible presence of an accessory bone. Specimens were radiographed and dissected to reveal the presence of an accessory bone and its relationship to the tibialis posterior tendon. Nineteen of the specimens exhibited hypertrophy of the tibialis posterior tendon and 19 specimens exhibited an accessory bone. Specimens exhibiting an accessory bone were divided into two categories. In one group, the accessory bone was located in the tibialis posterior tendon prior to its division and was separated from the tuberosity by at least 3 mm. In the other group, the accessory bone was located in the main segment of the tibialis posterior tendon, connected to the tuberosity of the navicular by fibrous tissue, and, in some cases, exhibited a central cavity between the accessory bone and tuberosity. The accessory bone of specimens in the first group was considered to be a sesamoid in the tibialis posterior tendon and the accessory bone in the second group was an ossicle considered to be the os tibiale externum. Linking the os tibiale externum to the tibiale component of the primitive tetrapod foot rather than to the prehallux component eliminates the use of the term "prehallux" as an alternative name for this ossicle.

  17. EMG and tibial shock upon the first attempt at barefoot running.

    PubMed

    Olin, Evan D; Gutierrez, Gregory M

    2013-04-01

    As a potential means to decrease their risk of injury, many runners are transitioning into barefoot running. Habitually shod runners tend to heel-strike (SHS), landing on their heel first, while barefoot runners tend to mid-foot or toe-strike (BTS), landing flat-footed or on the ball of their foot before bringing down the rest of the foot including the heel. This study compared muscle activity, tibial shock, and knee flexion angle in subjects between shod and barefoot conditions. Eighteen habitually SHS recreational runners ran for 3 separate 7-minute trials, including SHS, barefoot heel-strike (BHS), and BTS conditions. EMG, tibial shock, and knee flexion angle were monitored using bipolar surface electrodes, an accelerometer, and an electrogoniometer, respectively. A one-way MANOVA for repeated measures was conducted and several significant changes were noted between SHS and BTS, including significant increases in average EMG of the medial gastrocnemius (p=.05), average and peak tibial shock (p<.01), and the minimum knee flexion angle (p<.01). Based on our data, the initial change in mechanics may have detrimental effects on the runner. While it has been argued that BTS running may ultimately be less injurious, these data indicate that habitually SHS runners who choose to transition into a BTS technique must undertake the process cautiously. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Characterization of nonpolar a-plane GaN epi-layers grown on high-density patterned r-plane sapphire substrates

    NASA Astrophysics Data System (ADS)

    Jinno, Daiki; Otsuki, Shunya; Sugimori, Shogo; Daicho, Hisayoshi; Iwaya, Motoaki; Takeuchi, Tetsuya; Kamiyama, Satoshi; Akasaki, Isamu

    2018-02-01

    To reduce the number of threading dislocations (TDs) in nonpolar a-plane GaN (a-GaN) epi-layers grown on flat r-plane sapphire substrates (r-FSS), we investigated the effects on the crystalline quality of the a-GaN epi-layers of high-density patterned r-plane sapphire substrates (r-HPSS), the patterns of which were placed at intervals of several hundred nanometers. Two types of r-HPSS, the patterns of which had diameters and heights on the order of several hundred nanometers (r-NHPSS) or several micrometers (r-MHPSS), were prepared with conventional r-FSS. The effect of these r-HPSS on the a-GaN epi-layers was demonstrated by evaluating the surface morphology and the crystalline quality of the epi-layers. The surfaces of the a-GaN epi-layer grown on r-FSS and r-NHPSS were pit-free and mirror-like, whereas the surface of the a-GaN epi-layer grown on r-MHPSS was very rough due to the large, irregular GaN islands that grew on the patterns, mainly at the initial growth stage. The crystalline quality of the a-GaN epi-layer grown on r-NHPSS was better than that of the a-GaN epi-layer grown on r-FSS. We confirmed that there were fewer TDs in the a-GaN epi-layer grown on r-NHPSS than there were in the a-GaN epi-layer grown on r-FSS. The TDs propagating to the surface in a-GaN epi-layer grown on r-NHPSS were mainly generated on the flat sapphire regions between the patterns. Interestingly, it was also found that the TDs that propagated to the surface concentrated with a periodic pitch along the c-axis direction. The TD densities of a-GaN epi-layers grown on r-FSS and r-NHPSS were estimated to be approximately 5.0 × 1010 and 1.5 × 109 cm-2, respectively. This knowledge will contribute to the further development of a-GaN epi-layers for high-performance devices.

  19. Room-temperature optically pumped laser emission from a-plane GaN with high optical gain characteristics

    NASA Astrophysics Data System (ADS)

    Kuokstis, E.; Chen, C. Q.; Yang, J. W.; Shatalov, M.; Gaevski, M. E.; Adivarahan, V.; Khan, M. Asif

    2004-04-01

    Photoluminescence (PL) and optical gain (OG) spectra of a-plane GaN layers have been analyzed over a wide range of excitation intensities. The samples were fully coalesced layers grown by metalorganic chemical vapor deposition over r-plane sapphire substrates using epitaxial layer overgrowth (ELOG) and selective area lateral epitaxy (SALE) procedures. ELOG and SALE a-plane samples showed a strong stimulated emission line in backscattering-geometry PL spectra along with extremely high OG coefficient values (in SALE samples more than 2000 cm-1). Structures prepared with natural cleaved facet cavities based on these films were used to demonstrate optically pumped room-temperature lasing.

  20. Risk factors for tibial implant malpositioning in total knee arthrosplasty-consecutive series of one thousand, four hundred and seventeen cases.

    PubMed

    Gaillard, Romain; Cerciello, Simone; Lustig, Sebastien; Servien, Elvire; Neyret, Philippe

    2017-04-01

    Total knee arthroplasty (TKA) malalignment may result in pain and limited range of motion. The present study assessed the influence of different surgeon's and patient's related factors on the post-operative tibial tray coronal alignment. The charts and the x-rays of a continuous prospective series of 1417 TKAs operated upon between 1987 and 2015 were retrospectively reviewed. The long-leg AP views were performed at two months post-op and the tibial mechanical angle of the tibial tray was measured. Three groups were defined: varus (≤87° n = 167), valgus (≥93° n = 55) and well alignment (88° to 92° n = 1195). The influence of several pre-operative and peri-operative factors was investigated: surgeon handedness and experience (junior or senior), previous tibial osteotomies, Ahlbäck stage of osteoarthritits, pre-operative alignment, height and weight, age at surgery, approach (medial, lateral or tibial tubercle osteotomy), generation of implants, tray fixation, size of the tray and stem lenght. Univariate then multivariate analysis were performed to find out any correlation. Multivariate analysis showed a strong correlation between varus alignment of the tibial tray and pre-operative varus of the lower limb (p = 0.037), increased BMI (p = 0.016) and operated side opposite to the dominant surgeon's arm (p = 0.006). In a similar way a strong correlation was found between valgus alignment and pre-operative valgus of the limb (p = 0.026). Poor alignment of the tibial tray after TKA was associated with pre-operative malalignment of the lower limb, increased BMI and an index knee which was opposite to surgeon's dominant arm.

  1. Moore I postero-medial articular tibial fracture in alpine skiers: Surgical management and return to sports activity.

    PubMed

    Morin, Vincent; Pailhé, Régis; Sharma, Akash; Rouchy, René-Christopher; Cognault, Jérémy; Rubens-Duval, Brice; Saragaglia, Dominique

    2016-06-01

    Over the past 10 years, like many authors, we observed an increasing number of Moore I tibial plateau fractures related to alpine skiing for which the surgeon may face difficult choices regarding surgical approach and fixation means. Some authors have recently been suggesting a posterior approach associated to open reduction and osteosynthesis by a buttress plate. But in our knowledge there is no specific study on sports activity recovery after Moore I tibial fractures. The aim of this work was to assess sports activities and clinical outcomes after surgically treated Moore I tibial plateau fractures in an athletic population of skiers. We conducted a prospective case series between 2012 and 2014. This included fifteen patients aged 39.6±7 years whom presented with a Moore I tibial plateau fracture during a skiing accident. 12 cases (80%) presented with an associated tibial spine fracture. Treatment consisted of a standard antero-medial approach, with a medial para patellar arthrotomy to allow direct visualisation of articular reduction and spinal fixation. Two or three 6.5mm long cancellous bone screws were placed antero-posteriorly so as to ensure perfect compression of the fracture site. Radiological and functional results were assessed by an independent observer (Lysholm-Tegner, UCLA, KOOS scores) at the longest follow-up. Mean follow-up was 18.2±6 months (12-28). An immediate postoperative anatomical reduction was achieved in all cases and remained stable in time. At last follow-up Lysholm mean score was 85±14 points (59-100), UCLA score was 7.3±1.6 (4-10) and Tegner score was 4.6±1.3 (3-6). Mean KOOS score was 77±15 (54-97). 87% of patients had resumed their skiing activity and 93% were satisfied or very satisfied from their post-operative surgical outcome. We observed no pseudarthrosis or secondary varus displacement. In our series 87% of patients had resumed back to their sporting activities. Surgical management of Moore I tibial plateau fractures by

  2. MRI analysis of tibial PCL attachment in a large population of adult patients: reference data for anatomic PCL reconstruction.

    PubMed

    Teng, Yuanjun; Guo, Laiwei; Wu, Meng; Xu, Tianen; Zhao, Lianggong; Jiang, Jin; Sheng, Xiaoyun; Xu, Lihu; Zhang, Bo; Ding, Ning; Xia, Yayi

    2016-09-05

    Consistent reference data used for anatomic posterior cruciate ligament (PCL) reconstruction is not well defined. Quantitative guidelines defining the location of PCL attachment would aid in performing anatomic PCL reconstruction. The purpose was to characterize anatomic parameters of the PCL tibial attachment based on magnetic resonance imaging (MRI) in a large population of adult knees. The PCL tibial attachment site was examined in 736 adult knees with an intact PCL using 3.0-T proton density-weighted sagittal MRI. The outcomes measured were the anterior-posterior diameter (APD) of the tibial plateau; angle between the tibial plateau and the posterior tibial 'shelf' (the slope where the PCL tibial attachment site was) (PTS); length of the PTS; proximal, central, and distal PCL attachment positions as well as the width of the PCL attachment site; and vertical dimension of the PCL attachment site inferior from the tibial plateau. The average APD of the tibia plateau was 33.6 ± 3.5 mm, yielding significant differences between males (35.5 ± 3.0 mm) and females (31.6 ± 2.7 mm), P <.05, and there was a significantly decreasing trend with increasing age in males (P <.05). Mean angle between the tibial plateau and the PTS was 122.4° ± 8.1°, and subgroup analysis showed that the young group had a differently smaller angle (120.9° ± 7.5°) than the middle-aged (123.7° ± 8.2°) and the old (123.4° ± 7.7°) in males population, while there were no significant differences between sexes (P >.05). The proximal, central positions and width of the PCL attachment site were 13.4 ± 3.0 mm, 17.8 ± 3.0 mm and 9.6 ± 2.4 mm along the PTS, with significant differences between males and females (P <.05), and accounted for 60.0 % ± 9.1 %, 80.0 % ± 4.6 % and 43.3 % ± 9.7 % of the PTS respectively, with no significant differences between sexes and among age groups (all P >.05). This study provides reference

  3. In vivo tibial stiffness is maintained by whole bone morphology and cross-sectional geometry in growing female mice

    PubMed Central

    Main, Russell P.; Lynch, Maureen E.; van der Meulen, Marjolein C.H.

    2010-01-01

    Whole bone morphology, cortical geometry, and tissue material properties modulate skeletal stresses and strains that in turn influence skeletal physiology and remodeling. Understanding how bone stiffness, the relationship between applied load and tissue strain, is regulated by developmental changes in bone structure and tissue material properties is important in implementing biophysical strategies for promoting healthy bone growth and preventing bone loss. The goal of this study was to relate developmental patterns of in vivo whole bone stiffness to whole bone morphology, cross-sectional geometry, and tissue properties using a mouse axial loading model. We measured in vivo tibial stiffness in three age groups (6wks, 10wks, 16wks old) of female C57Bl/6 mice during cyclic tibial compression. Tibial stiffness was then related to cortical geometry, longitudinal bone curvature, and tissue mineral density using microcomputed tomography (microCT). Tibial stiffness and the stresses induced by axial compression were generally maintained from 6 to 16wks of age. Growth-related increases in cortical cross-sectional geometry and longitudinal bone curvature had counteracting effects on induced bone stresses and, therefore, maintained tibial stiffness similarly with growth. Tissue mineral density increased slightly from 6 to 16wks of age, and although the effects of this increase on tibial stiffness were not directly measured, its role in the modulation of whole bone stiffness was likely minor over the age range examined. Thus, whole bone morphology, as characterized by longitudinal curvature, along with cortical geometry, plays an important role in modulating bone stiffness during development and should be considered when evaluating and designing in vivo loading studies and biophysical skeletal therapies. PMID:20673665

  4. Open Tibial Inlay PCL Reconstruction: Surgical Technique and Clinical Outcomes.

    PubMed

    Vellios, Evan E; Jones, Kristofer J; McAllister, David R

    2018-06-01

    To review the current literature on clinical outcomes following open tibial inlay posterior cruciate ligament (PCL) reconstruction and provide the reader with a detailed description of the author's preferred surgical technique. Despite earlier biomechanical studies which demonstrated superiority of the PCL inlay technique when compared to transtibial techniques, recent longitudinal cohort studies have shown no significant differences in clinical or functional outcomes at 10-year follow-up. Furthermore, no significant clinical differences have been shown between graft types used and/or single- versus double-bundle reconstruction methods. The optimal treatment for the PCL-deficient knee remains unclear. Open tibial inlay PCL reconstruction is safe, reproducible, and avoids the "killer turn" that may potentially lead to graft weakening and failure seen in transtibial reconstruction methods. No significant differences in subjective outcomes or clinical laxity have been shown between single-bundle versus double-bundle reconstruction methods.

  5. The Effect of Arch Drop on Tibial Rotation and Tibiofemoral Contact Stress in Postpartum Women.

    PubMed

    Rabe, Kaitlin; Segal, Neil A; Waheed, Saphia; Anderson, Donald D

    2018-04-26

    Women are at greater risk for knee osteoarthritis and numerous other lower limb musculoskeletal disorders. Arch drop during pregnancy and the resultant excessive pronation of the feet may alter loading patterns and contribute to the greater prevalence of knee osteoarthritis in women. To determine the effect of arch drop on tibial rotation and tibiofemoral contact stress. Interventional study with internal control. Biomechanics laboratory. Eleven postpartum women (age 33.4 ± 5.3 years, body mass 76.1 ± 13.5 kg) who had lost arch height with pregnancy in a previous study. Subjects underwent standing computed tomography (SCT) with their knees in a 20° fixed-flexed position with and without semirigid arch supports to reconstitute prepregnancy arch height. Magnetic resonance imaging of the knee was acquired at a flexion angle equivalent to that of SCT. Bone and cartilage were manually segmented on the magnetic resonance images and segmented surfaces were registered to the 3-dimensional SCT image sets for the arch-supported and -unsupported conditions. These models were used to measure changes in tibial rotation, as well as to estimate contact stress in the medial and lateral tibiofemoral compartments, using computational methods. Change in tibial rotation and tibiofemoral contact stress with arch drop. Arch drop resulted in a mean tibial internal rotation of 0.75 ± 1.33° (P < .05). Changes in mean or peak contact stress were not detected. Arch drop causes internal tibial rotation, resulting in a shift in the tibiofemoral articulation. An associated increase in contact stress was not detected. Internal rotation of the tibia increases stress on the anterior cruciate ligament and menisci, potentially explaining the greater prevalence of knee disorders in postpartum women. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  6. Pair-Wise, Deformable Mirror, Image Plane-Based Diversity Electric Field Estimation for High Contrast Coronagraphy

    NASA Technical Reports Server (NTRS)

    Give'on, Amir; Kern, Brian D.; Shaklan, Stuart

    2011-01-01

    In this paper we describe the complex electric field reconstruction from image plane intensity measurements for high contrast coronagraphic imaging. A deformable mirror (DM) surface is modied with pairs of complementary shapes to create diversity in the image plane of the science camera where the intensity of the light is measured. Along with the Electric Field Conjugation correction algorithm, this estimation method has been used in various high contrast imaging testbeds to achieve the best contrasts to date both in narrow and in broad band light. We present the basic methodology of estimation in easy to follow list of steps, present results from HCIT and raise several open quations we are confronted with using this method.

  7. Tibial Bowing and Pseudarthrosis in Neurofibromatosis Type 1

    DTIC Science & Technology

    2015-01-01

    controlling for age and sex was used. However, there were no statistically significant differences between NF1 individuals with and without tibial...Dinorah Friedmann-Morvinski (The Salk Institute) presented a different model of glioblastoma in which tumors were induced from fully differentiated...a driver of Schwann cell tumorigenesis. Induction ofWnt signaling was sufficient to induce a transformed phenotype in human Schwann cells, while

  8. [Stability, bone healing and loss of correction after valgus realignment of the tibial head. A roentgen stereometry analysis].

    PubMed

    Pape, D; Adam, F; Rupp, S; Seil, R; Kohn, D

    2004-02-01

    In high tibial closing-wedge osteotomies (HTO), closure of an osteotomy gap after resection of a bony wedge can be associated with a fissure of the medial cortex of the tibial head (MCT). The effect of a broken MCT on the recurrence of varus deformity is disputed. In this study, serial roentgen stereometric analysis (RSA) was used to determine the fixation stability of a rigid internal "L" plate after HTO. Full weight lower limb radiographs were used to determine the sagittal alignment in patients with varying degrees of varus malalignment and correction over time. Forty-two patients with varus gonarthrosis stage I-III (Ahlback) were treated with HTO and internal fixation with an L-shaped rigid plate. Patients were followed by serial RSA, conventional radiographs, and clinical evaluation (Hospital of Special Surgery score) over a 12-month period. In 19 of 42 successive patients, an average wedge size of 6.9 degrees was resected leaving the MCT intact (group 1). In 23 of 42 of patients, the MCT was unintentionally fissured during surgery when an average 10.3 degrees -wedge was resected (group 2). In group 2, RSA revealed a fivefold increase in lateral displacement of the distal tibial segment within 3 weeks after HTO. Twelve weeks after HTO, translations between tibial segments were below the accuracy of the RSA setup in the majority of patients. Group 1 patients demonstrated a higher initial fixation stability, less occurrence of varus deformity, and a higher HSS score compared to patients with larger wedge sizes and frequent fracture of the MCT (group 2). Before bone healing is achieved, the integrity of the MCT plays a crucial role for the clinical and radiological outcome after HTO.

  9. Knee joint distraction compared with high tibial osteotomy: a randomized controlled trial.

    PubMed

    van der Woude, J A D; Wiegant, K; van Heerwaarden, R J; Spruijt, S; van Roermund, P M; Custers, R J H; Mastbergen, S C; Lafeber, F P J G

    2017-03-01

    Both, knee joint distraction as a relatively new approach and valgus-producing opening-wedge high tibial osteotomy (HTO), are knee-preserving treatments for knee osteoarthritis (OA). The efficacy of knee joint distraction compared to HTO has not been reported. Sixty-nine patients with medial knee joint OA with a varus axis deviation of <10° were randomized to either knee joint distraction (n = 23) or HTO (n = 46). Questionnaires were assessed at baseline and 3, 6, and 12 months. Joint space width (JSW) as a surrogate measure for cartilage thickness was determined on standardized semi-flexed radiographs at baseline and 1-year follow-up. All patient-reported outcome measures (PROMS) improved significantly over 1 year (at 1 year p < 0.02) in both groups. At 1 year, the HTO group showed slightly greater improvement in 4 of the 16 PROMS (p < 0.05). The minimum medial compartment JSW increased 0.8 ± 1.0 mm in the knee joint distraction group (p = 0.001) and 0.4 ± 0.5 mm in the HTO group (p < 0.001), with minimum JSW improvement in favour of knee joint distraction (p = 0.05). The lateral compartment showed a small increase in the knee joint distraction group and a small decrease in the HTO group, leading to a significant increase in mean JSW for knee joint distraction only (p < 0.02). Cartilaginous repair activity, as indicated by JSW, and clinical outcome improvement occurred with both, knee joint distraction and HTO. These findings suggest that knee joint distraction may be an alternative therapy for medial compartmental OA with a limited mechanical leg malalignment. Randomized controlled trial, Level I.

  10. Return to Work and Sport Following High Tibial Osteotomy: A Systematic Review.

    PubMed

    Ekhtiari, Seper; Haldane, Chloe E; de Sa, Darren; Simunovic, Nicole; Musahl, Volker; Ayeni, Olufemi R

    2016-09-21

    The purpose of this study was to examine (1) timelines for return to sport and work following high tibial osteotomy (HTO), and (2) whether patients return to sport and work at levels similar to preoperative levels. A systematic search was conducted across 3 databases (MEDLINE, Embase, and PubMed). Two reviewers independently screened the results for relevant articles. Data regarding patient demographics, indications, surgical technique, return to work and sport, and complication and failure rates were abstracted from eligible studies. Nineteen studies were included, involving 1,189 patients (64% male, 21% female, 15% unspecified) and 1,224 knees. Mean age was 46.2 years (range, 16 to 80 years). Opening-wedge HTO was most commonly used, followed by closing-wedge HTO and hemicallotasis. Mean follow-up was 65.4 months (range, 8 to 253 months). Overall, 87.2% of patients returned to sport postoperatively, and 78.6% returned at an equal or greater level. Among competitive athletes, 54% returned to competition. Overall, 84.5% of patients returned to work postoperatively, and 65.5% returned at an equal or greater level. Approximately 90% of patients who returned to work or sport did so within 1 year. The complication rate was 5.8%, with infection being the most common complication; 7.0% of patients progressed to a total knee arthroplasty at a mean of 6.7 years (range, 0.8 to 15 years) following HTO. The majority of patients undergoing HTO return to sport and work, and most return within 1 year of the operation. Most patients return to sport at a level equal to or greater than the preoperative level. Approximately two-thirds of patients return to an equal or greater level of physical work. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  11. Epidemiology of metatarsal stress fractures versus tibial and femoral stress fractures during elite training.

    PubMed

    Finestone, Aharon; Milgrom, Charles; Wolf, Omer; Petrov, Kaloyan; Evans, Rachel; Moran, Daniel

    2011-01-01

    The training of elite infantry recruits takes a year or more. Stress fractures are known to be endemic in their basic training and the clinical presentation of tibial, femoral, and metatarsal stress fractures are different. Stress fracture incidence during the subsequent progressively more demanding training is not known. The study hypothesis was that after an adaptation period, the incidence of stress fractures during the course of 1 year of elite infantry training would fall in spite of the increasingly demanding training. Seventy-six male elite infantry recruits were followed for the development of stress fractures during a progressively more difficult training program composed of basic training (1 to 14 weeks), advanced training (14 to 26 weeks), and unit training (26 to 52 weeks). Subjects were reviewed regularly and those with clinical suspicion of stress fracture were assessed using bone scan and X-rays. The incidence of stress fractures was 20% during basic training, 14% during advanced training and 23% during unit training. There was a statistically significant difference in the incidence of tibial and femoral stress fractures versus metatarsal stress fractures before and after the completion of phase II training at week 26 (p=0.0001). Seventy-eight percent of the stress fractures during phases I and II training were either tibial or femoral, while 91% of the stress fractures in phase III training were metatarsal. Prior participation in ball sports (p=0.02) and greater tibial length (p=0.05) were protective factors for stress fracture. The study hypothesis that after a period of soldier adaptation, the incidence of stress fractures would decrease in spite of the increasingly demanding elite infantry training was found to be true for tibial and femoral fractures after 6 months of training but not for metatarsal stress fractures. Further studies are required to understand the mechanism of this difference but physicians and others treating stress fractures

  12. Hindfoot Valgus following Interlocking Nail Treatment for Tibial Diaphysis Fractures: Can the Fibula Be Neglected?

    PubMed Central

    Uzun, Metin; Kara, Adnan; Adaş, Müjdat; Karslioğlu, Bülent; Bülbül, Murat; Beksaç, Burak

    2014-01-01

    Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated fibular fractures, except the distal one-third level, were included in this study. All tibial shaft fractures were anatomically reduced and fixed with interlocking intramedullary nails. Fibular fractures were managed conservatively. Hindfoot alignment was assessed clinically. Tibia and fibular lengths were compared to contralateral measurements using radiographs. Functional results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Foot and Ankle Disability Index Score (FADI). Results. Anatomic union, defined as equal length in operative and contralateral tibias, was achieved in 60 fractures (100%). Fibular shortening was identified in 42 fractures (68%). Mean fibular shortening was 1.2 cm (range, 0.5–2 cm). Clinical exams showed increased hindfoot valgus in 42 fractures (68%). The mean KOOS was 88.4, and the mean FADI score was 90. Conclusion. Fibular fractures in the middle or proximal one-third may need to be stabilized at the time of tibial intramedullary nail fixation to prevent development of hindfoot valgus due to fibular shortening. PMID:25544899

  13. Management of open tibial fractures – a regional experience

    PubMed Central

    Townley, WA; Nguyen, DQA; Rooker, JC; Dickson, JK; Goroszeniuk, DZ; Khan, MS; Camp, D

    2010-01-01

    INTRODUCTION The treatment of soft-tissue injuries associated with tibial diaphyseal fractures presents a clinical challenge that is best managed by a combined plastic and orthopaedic surgery approach. The current study was undertaken to assess early treatment outcomes and burden of service provision across five regional plastic surgery units in the South-West of England. SUBJECTS AND METHODS We conducted a prospective 6-month audit of open tibial diaphyseal fracture management in five plastic surgery units (Bristol, Exeter, Plymouth, Salisbury, Swansea) with a collective catchment of 9.2 million people. Detailed data were collected on patient demographics, injury pattern, surgical management and outcome followed to discharge. RESULTS The study group consisted of 55 patients (40 male, 15 female). Twenty-two patients presented directly to the emergency department at the specialist hospital (primary group), 33 patients were initially managed at a local hospital (tertiary group). The mean time from injury to soft tissue cover was significantly less (P < 0.001) in the primary group (3.6 ± 0.8 days) than the tertiary group (10.8 ± 2.2 days), principally due to a delay in referral in the latter group (5.4 ±1.7 days). Cover was achieved with 39 flaps (19 free, 20 local), eight split skin grafts. Nine wounds closed directly or by secondary intention. There were 11 early complications (20%) including one flap failure and four infections. The overall mean length of stay was 17.5 ± 2.8 days. CONCLUSIONS Multidisciplinary management of severe open tibial diaphyseal may not be feasible at presentation of injury depending on local hospital specialist services available. Our results highlight the need for robust assessment, triage and senior orthopaedic review in the early post-injury phase. However, broader improvements in the management of lower limb trauma will additionally require further development of combined specialist trauma centres. PMID:21047449

  14. Medial tibial pain: a dynamic contrast-enhanced MRI study.

    PubMed

    Mattila, K T; Komu, M E; Dahlström, S; Koskinen, S K; Heikkilä, J

    1999-09-01

    The purpose of this study was to compare the sensitivity of different magnetic resonance imaging (MRI) sequences to depict periosteal edema in patients with medial tibial pain. Additionally, we evaluated the ability of dynamic contrast-enhanced imaging (DCES) to depict possible temporal alterations in muscular perfusion within compartments of the leg. Fifteen patients with medial tibial pain were examined with MRI. T1-, T2-weighted, proton density axial images and dynamic and static phase post-contrast images were compared in ability to depict periosteal edema. STIR was used in seven cases to depict bone marrow edema. Images were analyzed to detect signs of compartment edema. Region-of-interest measurements in compartments were performed during DCES and compared with controls. In detecting periosteal edema, post-contrast T1-weighted images were better than spin echo T2-weighted and proton density images or STIR images, but STIR depicted the bone marrow edema best. DCES best demonstrated the gradually enhancing periostitis. Four subjects with severe periosteal edema had visually detectable pathologic enhancement during DCES in the deep posterior compartment of the leg. Percentage enhancement in the deep posterior compartment of the leg was greater in patients than in controls. The fast enhancement phase in the deep posterior compartment began slightly slower in patients than in controls, but it continued longer. We believe that periosteal edema in bone stress reaction can cause impairment of venous flow in the deep posterior compartment. MRI can depict both these conditions. In patients with medial tibial pain, MR imaging protocol should include axial STIR images (to depict bone pathology) with T1-weighted axial pre and post-contrast images, and dynamic contrast enhanced imaging to show periosteal edema and abnormal contrast enhancement within a compartment.

  15. Materials, devices, techniques, and applications for Z-plane focal plane array technology II; Proceedings of the Meeting, San Diego, CA, July 12, 13, 1990

    NASA Astrophysics Data System (ADS)

    Carson, John C.

    1990-11-01

    Various papers on materials, devices, techniques, and applications for X-plane focal plane array technology are presented. Individual topics addressed include: application of Z-plane technology to the remote sensing of the earth from GEO, applications of smart neuromorphic focal planes, image-processing of Z-plane technology, neural network Z-plane implementation with very high interconnection rates, using a small IR surveillance satellite for tactical applications, establishing requirements for homing applications, Z-plane technology. Also discussed are: on-array spike suppression signal processing, algorithms for on-focal-plane gamma circumvention and time-delay integration, current HYMOSS Z-technology, packaging of electrons for on- and off-FPA signal processing, space/performance qualification of tape automated bonded devices, automation in tape automated bonding, high-speed/high-volume radiometric testing of Z-technology focal planes, 128-layer HYMOSS-module fabrication issues, automation of IRFPA production processes.

  16. Intramedullary nailing in the treatment of aseptic tibial nonunion.

    PubMed

    Megas, P; Panagiotopoulos, E; Skriviliotakis, S; Lambiris, E

    2001-04-01

    Fifty patients suffering from aseptic tibial nonunion underwent reamed intramedullary nailing (I.N.) and were retrospectively reviewed. Thirty-six patients were initially treated with external fixation, six with plate and screws, one with a static I.N., and seven with plaster of Paris. Eighteen of the fractures were initially open (A: 5, B: 6, and C: 7 according to the Gustilo classification). In 34 cases a closed procedure was performed, whereas in sixteen, an opening at the nonunion site was unavoidable either to remove metalwork or realign the fragments. Following failed external fixation, secondary I.N. was performed at least 10 days after removal of the device. Bone grafts from the iliac crest were used in three cases, and a fibular osteotomy was performed in 33. Patients were followed up for an average of 2.5 years after nailing, ranging from 10 months to 7 years. A solid union was achieved in all patients within a period of 6 months. One patient developed late infection, which settled after nail removal and one patient developed impending compartment syndrome which was detected on the first post-operative day and was treated with a fasciotomy. Transient peroneal nerve palsy occurred in one patient and this recovered in 3 months, whereas in nine patients a clinically acceptable deformity was noticed. In conclusion, we believe that reamed intramedullary nailing is a highly effective treatment for aseptic tibial nonunions. Early and late complications are rare and bone graft is rarely needed. The method allows early weight bearing even before solid union occurs, short hospitalisation time and early return to work without external support.

  17. Navigated total knee arthroplasty: is it error-free?

    PubMed

    Chua, Kerk Hsiang Zackary; Chen, Yongsheng; Lingaraj, Krishna

    2014-03-01

    The aim of this study was to determine whether errors do occur in navigated total knee arthroplasty (TKAs) and to study whether errors in bone resection or implantation contribute to these errors. A series of 20 TKAs was studied using computer navigation. The coronal and sagittal alignments of the femoral and tibial cutting guides, the coronal and sagittal alignments of the final tibial implant and the coronal alignment of the final femoral implant were compared with that of the respective bone resections. To determine the post-implantation mechanical alignment of the limb, the coronal alignment of the femoral and tibial implants was combined. The median deviation between the femoral cutting guide and bone resection was 0° (range -0.5° to +0.5°) in the coronal plane and 1.0° (range -2.0° to +1.0°) in the sagittal plane. The median deviation between the tibial cutting guide and bone resection was 0.5° (range -1.0° to +1.5°) in the coronal plane and 1.0° (range -1.0° to +3.5°) in the sagittal plane. The median deviation between the femoral bone resection and the final implant was 0.25° (range -2.0° to 3.0°) in the coronal plane. The median deviation between the tibial bone resection and the final implant was 0.75° (range -3.0° to +1.5°) in the coronal plane and 1.75° (range -4.0° to +2.0°) in the sagittal plane. The median post-implantation mechanical alignment of the limb was 0.25° (range -3.0° to +2.0°). When navigation is used only to guide the positioning of the cutting jig, errors may arise in the manual, non-navigated steps of the procedure. Our study showed increased cutting errors in the sagittal plane for both the femur and the tibia, and following implantation, the greatest error was seen in the sagittal alignment of the tibial component. Computer navigation should be used not only to guide the positioning of the cutting jig, but also to check the bone resection and implant position during TKA. IV.

  18. Effect of axial tibial torque direction on ACL relative strain and strain rate in an in vitro simulated pivot landing.

    PubMed

    Oh, Youkeun K; Kreinbrink, Jennifer L; Wojtys, Edward M; Ashton-Miller, James A

    2012-04-01

    Anterior cruciate ligament (ACL) injuries most frequently occur under the large loads associated with a unipedal jump landing involving a cutting or pivoting maneuver. We tested the hypotheses that internal tibial torque would increase the anteromedial (AM) bundle ACL relative strain and strain rate more than would the corresponding external tibial torque under the large impulsive loads associated with such landing maneuvers. Twelve cadaveric female knees [mean (SD) age: 65.0 (10.5) years] were tested. Pretensioned quadriceps, hamstring, and gastrocnemius muscle-tendon unit forces maintained an initial knee flexion angle of 15°. A compound impulsive test load (compression, flexion moment, and internal or external tibial torque) was applied to the distal tibia while recording the 3D knee loads and tibofemoral kinematics. AM-ACL relative strain was measured using a 3 mm DVRT. In this repeated measures experiment, the Wilcoxon signed-rank test was used to test the null hypotheses with p < 0.05 considered significant. The mean (±SD) peak AM-ACL relative strains were 5.4 ± 3.7% and 3.1 ± 2.8% under internal and external tibial torque, respectively. The corresponding mean (± SD) peak AM-ACL strain rates reached 254.4 ± 160.1%/s and 179.4 ± 109.9%/s, respectively. The hypotheses were supported in that the normalized mean peak AM-ACL relative strain and strain rate were 70 and 42% greater under internal than under external tibial torque, respectively (p = 0.023, p = 0.041). We conclude that internal tibial torque is a potent stressor of the ACL because it induces a considerably (70%) larger peak strain in the AM-ACL than does a corresponding external tibial torque. Copyright © 2011 Orthopaedic Research Society.

  19. Ketorolac Administered in the Recovery Room for Acute Pain Management Does Not Affect Healing Rates of Femoral and Tibial Fractures.

    PubMed

    Donohue, David; Sanders, Drew; Serrano-Riera, Rafa; Jordan, Charles; Gaskins, Roger; Sanders, Roy; Sagi, H Claude

    2016-09-01

    To determine whether ketorolac administered in the immediate perioperative period affects the rate of nonunion in femoral and tibial shaft fractures. Retrospective comparative study. Single Institution, Academic Level 1 Trauma Center. Three hundred and thirteen skeletally mature patients with 137 femoral shaft (OTA 32) and 191 tibial shaft (OTA 42) fractures treated with intramedullary rod fixation. Eighty patients with 33 femoral shaft and 52 tibial shaft fractures were administered ketorolac within the first 24 hours after surgery (group 1-study group). Two-hundred thirty-three patients with 104 femoral shaft and 139 tibial shaft fractures were not (group 2-control group). Rate of reoperation for repair of a nonunion and time to union. Average time to union of the femur was 147 days for group 1 and 159 days for group 2 (P = 0.57). Average time to union of the tibia was 175 days for group 1 and 175 days for group 2 (P = 0.57). There were 3 femoral nonunions (9%) in group 1 and eleven femoral nonunions (11.6%) in group 2 (P = 1.00). There were 3 tibial nonunions (5.8%) in group 1 and 17 tibial nonunions (12.2%) in group 2 (P = 0.29). The average dose of ketorolac for patients who healed their fracture was 85 mg, whereas it was 50 mg for those who did not (P = 0.27). All patients with a nonunion in the study group were current smokers. Ketorolac administered in the first 24 hours after fracture repair for acute pain management does not seem to have a negative impact on time to healing or incidence of nonunion for femoral or tibial shaft fractures. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  20. EFFECT OF AXIAL TIBIAL TORQUE DIRECTION ON ACL RELATIVE STRAIN AND STRAIN RATE IN AN IN VITRO SIMULATED PIVOT LANDING

    PubMed Central

    Oh, Youkeun K.; Kreinbrink, Jennifer L.; Wojtys, Edward M.; Ashton-Miller, James A.

    2011-01-01

    Anterior cruciate ligament (ACL) injuries most frequently occur under the large loads associated with a unipedal jump landing involving a cutting or pivoting maneuver. We tested the hypotheses that internal tibial torque would increase the anteromedial (AM) bundle ACL relative strain and strain rate more than would the corresponding external tibial torque under the large impulsive loads associated with such landing maneuvers. Twelve cadaveric female knees [mean (SD) age: 65.0 (10.5) years] were tested. Pretensioned quadriceps, hamstring and gastrocnemius muscle-tendon unit forces maintained an initial knee flexion angle of 15°. A compound impulsive test load (compression, flexion moment and internal or external tibial torque) was applied to the distal tibia while recording the 3-D knee loads and tibofemoral kinematics. AM-ACL relative strain was measured using a 3mm DVRT. In this repeated measures experiment, the Wilcoxon Signed-Rank test was used to test the null hypotheses with p<0.05 considered significant. The mean (± SD) peak AM-ACL relative strains were 5.4±3.7 % and 3.1±2.8 % under internal and external tibial torque, respectively. The corresponding mean (± SD) peak AM-ACL strain rates reached 254.4±160.1 %/sec and 179.4±109.9 %/sec, respectively. The hypotheses were supported in that the normalized mean peak AM-ACL relative strain and strain rate were 70% and 42% greater under internal than external tibial torque, respectively (p=0.023, p=0.041). We conclude that internal tibial torque is a potent stressor of the ACL because it induces a considerably (70%) larger peak strain in the AM-ACL than does a corresponding external tibial torque. PMID:22025178

  1. High-order integral equation methods for problems of scattering by bumps and cavities on half-planes.

    PubMed

    Pérez-Arancibia, Carlos; Bruno, Oscar P

    2014-08-01

    This paper presents high-order integral equation methods for the evaluation of electromagnetic wave scattering by dielectric bumps and dielectric cavities on perfectly conducting or dielectric half-planes. In detail, the algorithms introduced in this paper apply to eight classical scattering problems, namely, scattering by a dielectric bump on a perfectly conducting or a dielectric half-plane, and scattering by a filled, overfilled, or void dielectric cavity on a perfectly conducting or a dielectric half-plane. In all cases field representations based on single-layer potentials for appropriately chosen Green functions are used. The numerical far fields and near fields exhibit excellent convergence as discretizations are refined-even at and around points where singular fields and infinite currents exist.

  2. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    PubMed

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  3. Regional fibrocartilage variations in human anterior cruciate ligament tibial insertion: a histological three-dimensional reconstruction.

    PubMed

    Dai, Can; Guo, Lin; Yang, Liu; Wu, Yi; Gou, Jingyue; Li, Bangchun

    2015-02-01

    We studied anterior cruciate ligament (ACL) tibial insertion architecture in humans and investigated regional differences that could suggest unequal force transmission from ligament to bone. ACL tibial insertions were processed histologically. With Photoshop software, digital images taken from the histological slides were collaged, contour lines were drawn, and different gray values were filled based on the structure. The data were exported to Amira software for three-dimensional reconstruction. The uncalcified fibrocartilage (UF) layer was divided into three regions: lateral, medial and posterior according to the architecture. The UF zone was significantly thicker laterally than medially or posteriorly (p < 0.05). Similarly, the calcified fibrocartilage (CF) thickness was significantly greater in the lateral part of the enthesis compared to the medial and posterior parts (p < 0.05). The UF quantity (more UF laterally) corresponding to the CF quantity (more CF laterally) at the ACL tibial insertion provides further evidence suggesting that the load transferred from the ACL to the tibia was greater laterally than medially and posteriorly.

  4. Tibial dyschondroplasia associated proteomic changes in chicken growth plate cartilage

    USDA-ARS?s Scientific Manuscript database

    Tibial dyschondroplasia (TD) is a poultry leg problem that affects the proximal growth plate of tibia preventing its transition to bone. To understand the disease-induced proteomic changes we compared the protein extracts of cartilage from normal and TD- affected growth plates. TD was induced by fe...

  5. Treatment of open tibial fracture with bone defect caused by high velocity missiles: a case report.

    PubMed

    Golubović, Zoran; Vukajinović, Zoran; Stojiljković, Predrag; Golubović, Ivan; Visnjić, Aleksandar; Radovanović, Zoran; Najman, Stevo

    2013-01-01

    Tibia fracture caused by high velocity missiles is mostly comminuted and followed by bone defect which makes their healing process extremely difficult and prone to numerous complications. A 34-year-old male was wounded at close range by a semi-automatic gun missile. He was wounded in the distal area of the left tibia and suffered a massive defect of the bone and soft tissue. After the primary treatment of the wound, the fracture was stabilized with an external fixator type Mitkovic, with convergent orientation of the pins. The wound in the medial region of the tibia was closed with the secondary stitch, whereas the wound in the lateral area was closed with the skin transplant after Thiersch. Due to massive bone defect in the area of the rifle-missile wound six months after injury, a medical team placed a reconstructive external skeletal fixator type Mitkovic and performed corticotomy in the proximal metaphyseal area of the tibia. By the method of bone transport (distractive osteogenesis), the bone defect of the tibia was replaced. After the fracture healing seven months from the secondary surgery, the fixator was removed and the patient was referred to physical therapy. Surgical treatment of wounds, external fixation, performing necessary debridement, adequate antibiotic treatment and soft and bone tissue reconstruction are essential in achieving good results in patients with the open tibial fracture with bone defect caused by high velocity missiles. Reconstruction of bone defect can be successfully treated by reconstructive external fixator Mitkovic.

  6. The effect of muscle fatigue on in vivo tibial strains.

    PubMed

    Milgrom, Charles; Radeva-Petrova, Denitsa R; Finestone, Aharon; Nyska, Meir; Mendelson, Stephen; Benjuya, Nisim; Simkin, Ariel; Burr, David

    2007-01-01

    Stress fracture is a common musculoskeletal problem affecting athletes and soldiers. Repetitive high bone strains and strain rates are considered to be its etiology. The strain level necessary to cause fatigue failure of bone ex vivo is higher than the strains recorded in humans during vigorous physical activity. We hypothesized that during fatiguing exercises, bone strains may increase and reach levels exceeding those measured in the non-fatigued state. To test this hypothesis, we measured in vivo tibial strains, the maximum gastrocnemius isokinetic torque and ground reaction forces in four subjects before and after two fatiguing levels of exercise: a 2km run and a 30km desert march. Strains were measured using strain-gauged staples inserted percutaneously in the medial aspect of their mid-tibial diaphysis. There was a decrease in the peak gastrocnemius isokinetic torque of all four subjects' post-march as compared to pre-run (p=0.0001), indicating the presence of gastrocnemius muscle fatigue. Tension strains increased 26% post-run (p=0.002, 95 % confidence interval (CI) and 29% post-march (p=0.0002, 95% CI) as compared to the pre-run phase. Tension strain rates increased 13% post-run (p=0.001, 95% CI) and 11% post-march (p=0.009, 95% CI) and the compression strain rates increased 9% post-run (p=0.0004, 95% CI) and 17% post-march (p=0.0001, 95% CI). The fatigue state increases bone strains well above those recorded in rested individuals and may be a major factor in the stress fracture etiology.

  7. A new aiming guide can create the tibial tunnel at favorable position in transtibial pullout repair for the medial meniscus posterior root tear.

    PubMed

    Furumatsu, T; Kodama, Y; Fujii, M; Tanaka, T; Hino, T; Kamatsuki, Y; Yamada, K; Miyazawa, S; Ozaki, T

    2017-05-01

    Injuries to the medial meniscus (MM) posterior root lead to accelerated cartilage degeneration of the knee. An anatomic placement of the MM posterior root attachment is considered to be critical in transtibial pullout repair of the medial meniscus posterior root tear (MMPRT). However, tibial tunnel creation at the anatomic attachment of the MM posterior root is technically difficult using a conventional aiming device. The aim of this study was to compare two aiming guides. We hypothesized that a newly-developed guide, specifically designed, creates the tibial tunnel at an adequate position rather than a conventional device. Twenty-six patients underwent transtibial pullout repairs. Tibial tunnel creation was performed using the Multi-use guide (8 cases) or the PRT guide that had a narrow twisting/curving shape (18 cases). Three-dimensional computed tomography images of the tibial surface were evaluated using the Tsukada's measurement method postoperatively. Expected anatomic center of the MM posterior root attachment and tibial tunnel center were evaluated using the percentage-based posterolateral location on the tibial surface. Percentage distance between anatomic center and tunnel center was calculated. Anatomic center of the MM posterior root footprint located at a position of 78.5% posterior and 39.4% lateral. Both tunnels were anteromedial but tibial tunnel center located at a more favorable position in the PRT group: percentage distance was significantly smaller in the PRT guide group (8.7%) than in the Multi-use guide group (13.1%). The PRT guide may have great advantage to achieve a more anatomic location of the tibial tunnel in MMPRT pullout repair. III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Tibial Plateau Fractures in Elderly Patients

    PubMed Central

    Vemulapalli, Krishna C.; Gary, Joshua L.; Donegan, Derek J.

    2016-01-01

    Tibial plateau fractures are common in the elderly population following a low-energy mechanism. Initial evaluation includes an assessment of the soft tissues and surrounding ligaments. Most fractures involve articular depression leading to joint incongruity. Treatment of these fractures may be complicated by osteoporosis, osteoarthritis, and medical comorbidities. Optimal reconstruction should restore the mechanical axis, provide a stable construct for mobilization, and reestablish articular congruity. This is accomplished through a variety of internal or external fixation techniques or with acute arthroplasty. Regardless of the treatment modality, particular focus on preservation and maintenance of the soft tissue envelope is paramount. PMID:27551570

  9. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis.

    PubMed

    Metcalfe, David; Hickson, Craig J; McKee, Lesley; Griffin, Xavier L

    2015-12-01

    It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures.

  10. Tibial nerve stimulation for overactive bladder syndrome unresponsive to medical therapy.

    PubMed

    Ridout, A E; Yoong, W

    2010-02-01

    Overactive bladder syndrome is defined as a symptom syndrome which includes urinary urgency, with or without urge incontinence, usually accompanied by frequency (>8 micturitions/24 h) and nocturia. Conservative treatment usually comprises behavioural techniques, bladder retraining, pelvic floor re-education and pharmacotherapy but up to 30% of patients will remain refractory to treatment. Although second-line treatment options such as sacral nerve stimulation and intravesical botulinum A injections are valuable additions to the therapeutic arsenal, they are relatively invasive and can have serious side-effects. Inhibition of detrusor activity by peripheral neuromodulation of the posterior tibial nerve was first described in 1983, with recent authors further confirming a 60-80% positive response rate. This review was undertaken to examine published literature on percutaneous tibial nerve stimulation and to discuss outcome measures, maintenance therapy and prognostic factors of this technique.

  11. Increases in tibial force imbalance but not changes in tibiofemoral laxities are caused by varus-valgus malalignment of the femoral component in kinematically aligned TKA.

    PubMed

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-01-29

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by 2° and 4° of varus-valgus (V-V) malalignment of the femoral component in kinematically aligned total knee arthroplasty (TKA) and use the results to detemine sensitivities to errors in making the distal femoral resections. Because V-V malalignment would introduce the greatest changes in the alignment of the articular surfaces at 0° flexion, the hypotheses were that the greatest increases in tibial force imbalance would occur at 0° flexion, that primarily V-V laxity would significantly change at this flexion angle, and that the tibial force imbalance would increase and laxities would change in proportion to the degree of V-V malalignment. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced V-V malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured during passive knee flexion-extension between 0° to 120° using a custom tibial force sensor. Eight laxities were measured from 0° to 120° flexion using a six degree-of-freedom load application system. With the tibial component kinematically aligned, the increase in the tibial force imbalance from that of the reference component at 0° of flexion was sensitive to the degree of V-V malalignment of the femoral component. Sensitivities were 54 N/deg (medial tibial force increasing > lateral tibial force) (p < 0.0024) and 44 N/deg (lateral tibial force increasing > medial tibial force) (p < 0.0077) for varus and valgus malalignments, respectively. Varus

  12. Risk of total knee arthroplasty after operatively treated tibial plateau fracture: a matched-population-based cohort study.

    PubMed

    Wasserstein, David; Henry, Patrick; Paterson, J Michael; Kreder, Hans J; Jenkinson, Richard

    2014-01-15

    The aims of operative treatment of displaced tibial plateau fractures are to stabilize the injured knee to restore optimal function and to minimize the risk of posttraumatic arthritis and the eventual need for total knee arthroplasty. The purpose of our study was to define the rate of subsequent total knee arthroplasty after tibial plateau fractures in a large cohort and to compare that rate with the rate in the general population. All patients sixteen years of age or older who had undergone surgical treatment of a tibial plateau fracture from 1996 to 2009 in the province of Ontario, Canada, were identified from administrative health databases with use of surgeon fee codes. Each member of the tibial plateau fracture cohort was matched to four individuals from the general population according to age, sex, income, and urban/rural residence. The rates of total knee arthroplasty at two, five, and ten years were compared by using time-to-event analysis. A separate Cox proportional hazards model was used to explore the influence of patient, provider, and surgical factors on the time to total knee arthroplasty. We identified 8426 patients (48.5% female; median age, 48.9 years) who had undergone fixation of a tibial plateau fracture and matched them to 33,698 controls. The two, five, and ten-year rates of total knee arthroplasty in the plateau fracture and control cohorts were 0.32% versus 0.29%, 5.3% versus 0.82%, and 7.3% versus 1.8%, respectively (p < 0.0001). After adjustment for comorbidity, plateau fracture surgery was found to significantly increase the likelihood of total knee arthroplasty (hazard ratio [HR], 5.29 [95% confidence interval, 4.58, 6.11]; p < 0.0001). Higher rates of total knee arthroplasty were also associated with increasing age (HR, 1.03 [1.03, 1.04] per year over the age of forty-eight; p < 0.0001), bicondylar fracture (HR, 1.53 [1.26, 1.84]; p < 0.0001), and greater comorbidity (HR, 2.17 [1.70, 2.77]; p < 0.001). Ten years after tibial plateau

  13. Internal-external malalignment of the femoral component in kinematically aligned total knee arthroplasty increases tibial force imbalance but does not change laxities of the tibiofemoral joint.

    PubMed

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-06-01

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by  2° and 4° of internal-external (I-E) malalignment of the femoral component in kinematically aligned total knee arthroplasty. Because I-E malalignment would introduce the greatest changes to the articular surfaces near 90° of flexion, the hypotheses were that the tibial force imbalance would be significantly increased near 90° flexion and that primarily varus-valgus laxity would be affected near 90° flexion. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced I-E malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured from 0° to 120° flexion using a custom tibial force sensor. Bidirectional laxities in four degrees of freedom were measured from 0° to 120° flexion using a custom load application system. Tibial force imbalance increased the greatest at 60° flexion where a regression analysis against the degree of I-E malalignment yielded sensitivities (i.e. slopes) of 30 N/° (medial tibial force > lateral tibial force) and 10 N/° (lateral tibial force > medial tibial force) for internal and external malalignments, respectively. Valgus laxity increased significantly with the 4° external component with the greatest increase of 1.5° occurring at 90° flexion (p < 0.0001). With the tibial component correctly aligned, I-E malalignment of the femoral component caused significant increases in tibial force imbalance. Minimizing I-E malalignment lowers the increase in the tibial force imbalance. By keeping

  14. Clinical, radiological and histological evaluation of biphasic calcium phosphate bioceramic wedges filling medial high tibial valgisation osteotomies.

    PubMed

    Rouvillain, J L; Lavallé, F; Pascal-Mousselard, H; Catonné, Y; Daculsi, G

    2009-10-01

    We report clinical, radiological and histological findings following high tibial valgisation osteotomy (HTVO) using micro-macroporous biphasic calcium phosphate wedges fixed with a plate and locking screws. From 1999 to 2002, 43 knees were operated on and studied prospectively. All underwent clinical and radiological follow-up at days 1, 90, and 365 to evaluate consolidation and bone substitute interfaces. Additionally, biopsies were taken for histology at least 1 year after implantation from 10 patients who requested plate removal. Radiologically, consolidation was observed in 98% of cases. At 1 year, correction was unchanged in 95% of cases. Histological analysis revealed considerable MBCP resorption and bone ingrowth, both into the pores and replacing the bioceramic material. Polarised light microscopy confirmed normal bony architecture with trabecular and/or dense lamellar bone growth at the expense of the wedge implants. X-ray and micro-CT scan revealed a well organised and mineralised structure in the newly-formed bone. This study shows that using MBCP wedges in combination with orientable locking screws and a plate is a simple, safe and fast surgical technique for HTVO. The is the first study to examine the results by histological analysis, which confirmed good outcomes.

  15. Asymmetry in gait pattern following bicondylar tibial plateau fractures-A prospective one-year cohort study.

    PubMed

    Elsoe, Rasmus; Larsen, Peter

    2017-07-01

    Despite the high number of studies evaluating outcomes following tibial plateau fractures, the literature lacks studies including the objective assessment of gait pattern. The purpose of the present study was to evaluate asymmetry in gait patterns at 12 months after frame removal following ring fixation of a tibial plateau fracture. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns 12 months after frame removal measured with a pressure-sensitive mat. The mat registers footprints and present gait speed, cadence, as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. Twenty-three patients were included with a mean age of 54.4 years (32-78 years). Patients presented with a shorter step-length of the injured leg compared to the non-injured leg (asymmetry of 11.3%). Analysis of single-support showed shorter support time of the injured leg compared to the non-injured leg (asymmetry of 8.7%). Moreover, analysis of swing-time showed increased swing-time of the injured leg (asymmetry of 8.9%). Compared to a healthy reference population, increased asymmetry in all gait patterns was observed. The association between asymmetry and health-related quality of life (HRQOL) showed moderate associations (single-support: R=0.50, P=0.03; step-length: R=0.43, P=0.07; swing-time: R=0.46, P=0.05). Compared to a healthy reference population, gait asymmetry is common 12 months after frame removal in patients treated with external ring fixation following a tibial plateau fracture of the tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Appropriate hinge position for prevention of unstable lateral hinge fracture in open wedge high tibial osteotomy.

    PubMed

    Nakamura, R; Komatsu, N; Fujita, K; Kuroda, K; Takahashi, M; Omi, R; Katsuki, Y; Tsuchiya, H

    2017-10-01

    Open wedge high tibial osteotomy (OWHTO) for medial-compartment osteoarthritis of the knee can be complicated by intra-operative lateral hinge fracture (LHF). We aimed to establish the relationship between hinge position and fracture types, and suggest an appropriate hinge position to reduce the risk of this complication. Consecutive patients undergoing OWHTO were evaluated on coronal multiplanar reconstruction CT images. Hinge positions were divided into five zones in our new classification, by their relationship to the proximal tibiofibular joint (PTFJ). Fractures were classified into types I, II, and III according to the Takeuchi classification. Among 111 patients undergoing OWHTOs, 22 sustained lateral hinge fractures. Of the 89 patients without fractures, 70 had hinges in the zone within the PTFJ and lateral to the medial margin of the PTFJ (zone WL), just above the PTFJ. Among the five zones, the relative risk of unstable fracture was significantly lower in zone WL (relative risk 0.24, confidence interval 0.17 to 0.34). Zone WL appears to offer the safest position for the placement of the osteotomy hinge when trying to avoid a fracture at the osteotomy site. Cite this article: Bone Joint J 2017;99B10:1313-18. ©2017 The British Editorial Society of Bone & Joint Surgery.

  17. Tibial plateau fracture after anterior cruciate ligament reconstruction: Role of the interference screw resorption in the stress riser effect.

    PubMed

    Thaunat, Mathieu; Nourissat, Geoffroy; Gaudin, Pascal; Beaufils, Philippe

    2006-06-01

    We report a case of tibial plateau fracture after previous anterior cruciate ligament (ACL) reconstruction using patellar tendon autograft and bioabsorbable screws 4 years previously. The fracture occurred through the tibial tunnel. The interference screw had undergone complete resorption and the tunnel widening had increased. The resorption of the interference screw did not simultaneously promote and foster the growth of surrounding bone tissue. Therefore, the area of reactive tissue left by the screw resorption in an enlarged bone tunnel may lead to vulnerability of the tibial plateau. Stress risers would occur following ACL reconstruction if either resorption is not complete or bony integration is not complete.

  18. [Minimally invasive percutaneous plate osteosynthesis versus open reduction and internal fixation for distal tibial fractures in adults: a meta-analysis].

    PubMed

    Zhang, Qing-xi; Gao, Fu-qiang; Sun, Wei; Wang, Yun-ting; Yang, Yu-run; Li, Zirong

    2015-08-01

    To perform a meta-analysis on clinical outcomes of minimally invasive percutaneous plate osteosynthesis (MIPPO) or open reduction and internal fixation (ORIF) for distal tibial fractures in adults. Pubmed database (from 1968 to March 2014), Cochrane library and CNKI database (from 1998 to March 2014) were searched. Case-control study on minimally invasive percutaneous plate osteosynthesis (MIPPO) or open reduction and internal fixation (ORIF) for distal tibial fractures in adults were chosen,and postoperative infection, operative time, blood loss, fracture nonunion rate, delayed union,fracture malunion rate were seen as evaluation index for meta analysis. The system review was performed using the method recommended by the Cochrane Collaboration. Totally 5 studies (366 patients) were enrolled. Meta-analysis showed that there were significant meaning in postoperative infection between MIPPO and ORIF [OR = 0.23,95% CI (0.06,0.92), P = 0.04]; fracture nonunion rate in MIPPO was lower than in ORIF group [OR = 0.16, 95% CI (0.03,0.76), P = 0.02]; operative time in MIPPO was shorter than in ORIF group, and had significant difference [MD = -14.42, 95% CI (-27.79, -1.05), P < 0.05]; blood loss in MIPPO was less than in ORIF group [MD= -87.17,95%CI (-99.20, -75.15), P < 0.05]; there was no obviously meaning in delayed union between two groups. For distal tibial fractures in adults, MIPPO has, advantages of short operative time, less blood loss, lower incidence of infection and fracture non-uniom, but with high fracture malunion rate. MIPPO for distal tibial fractures in adults is better than ORIF, and the best treatment should choose according to patient's condition.

  19. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    PubMed

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted

  20. Technique tip: use of anterior cruciate ligament jig for hindfoot fusion by calcanio-talo-tibial nail.

    PubMed

    Haque, Syed; Sarkar, Jay

    2012-08-01

    The use of intramedullary nail fixation for tibio-talo-calcaneal fusion is gaining popularity. There is chance of failure of procedure following faulty operative technique specially alignment. The article describes a useful application of tibial tunnel jig in inserting the calcanio-talo-tibial guide wire. There is precision of few millimeters in the exit point of guide wire on talus. The authors believe that this helps in better positioning of nail and hence better alignment and better operative outcome.

  1. Popliteal versus tibial retrograde access for subintimal arterial flossing with antegrade-retrograde intervention (SAFARI) technique.

    PubMed

    Hua, W R; Yi, M Q; Min, T L; Feng, S N; Xuan, L Z; Xing, J

    2013-08-01

    This study aimed to ascertain differences in benefit and effectiveness of popliteal versus tibial retrograde access in subintimal arterial flossing with the antegrade-retrograde intervention (SAFARI) technique. This was a retrospective study of SAFARI-assisted stenting for long chronic total occlusion (CTO) of TASC C and D superficial femoral lesions. 38 cases had superficial femoral artery lesions (23 TASC C and 15 TASC D). All 38 cases underwent SAFARI-assisted stenting. The ipsilateral popliteal artery was retrogradely punctured in 17 patients. A distal posterior tibial (PT) or dorsalis pedis (DP) artery was retrogradely punctured in 21 patients, and 16 of them were punctured after open surgical exposure. SAFARI technical success was achieved in all cases. There was no significant difference in 1-year primary patency (75% vs. 78.9%, p = .86), secondary patency (81.2% vs. 84.2%, p = .91) and access complications (p = 1.00) between popliteal and tibial retrograde access. There was statistical difference in operation time between popliteal (140.1 ± 28.4 min) and tibial retrograde access with PT/DP punctures after surgical vessel exposure (120.4 ± 23.0 min, p = .04). The SAFARI technique is a safe and feasible option for patients with infrainguinal CTO (TASC II C and D). The PT or DP as the retrograde access after surgical vessel exposure is a good choice when using the SAFARI technique. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. National Aerospace Plane Engine Seals: High Temperature Seal Performance Evaluation

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.

    1991-01-01

    The key to the successful development of the single stage to orbit National Aerospace Plane (NASP) is the successful development of combined cycle ramjet/scramjet engines that can propel the vehicle to 17,000 mph to reach low Earth orbit. To achieve engine performance over this speed range, movable engine panels are used to tailor engine flow that require low leakage, high temperature seals around their perimeter. NASA-Lewis is developing a family of new high temperature seals to form effective barriers against leakage of extremely hot (greater than 2000 F), high pressure (up to 100 psi) flow path gases containing hydrogen and oxygen. Preventing backside leakage of these explosive gas mixtures is paramount in preventing the potential loss of the engine or the entire vehicle. Seal technology development accomplishments are described in the three main areas of concept development, test, and evaluation and analytical development.

  3. Evaluation of cranial tibial and extensor carpi radialis reflexes before and after anesthetic block in cats.

    PubMed

    Tudury, Eduardo Alberto; de Figueiredo, Marcella Luiz; Fernandes, Thaiza Helena Tavares; Araújo, Bruno Martins; Bonelli, Marília de Albuquerque; Diogo, Camila Cardoso; Silva, Amanda Camilo; Santos, Cássia Regina Oliveira; Rocha, Nadyne Lorrayne Farias Cardoso

    2017-02-01

    Objectives This study aimed to test the extensor carpi radialis and cranial tibial reflexes in cats before and after anesthetic block of the brachial and lumbosacral plexus, respectively, to determine whether they depend on a myotatic reflex arc. Methods Fifty-five cats with a normal neurologic examination that were referred for elective gonadectomy were divided into group 1 (29 cats) for testing the extensor carpi radialis reflex, and group 2 (26 cats) for testing the cranial tibial reflex. In group 1, the extensor carpi radialis reflex was tested after anesthetic induction and 15 mins after brachial plexus block with lidocaine. In group 2, the cranial tibial, withdrawal and patellar reflexes were elicited in 52 hindlimbs and retested 15 mins after epidural anesthesia. Results In group 1, before the anesthetic block, 55.17% of the cats had a decreased and 44.83% had a normal extensor carpi radialis reflex. After the block, 68.96% showed a decreased and 27.59% a normal reflex. No cat had an increased or absent reflex before anesthetic block. In group 2, prior to the anesthetic block, 15.38% of the cats had a decreased cranial tibial reflex and 84.62% had a normal response, whereas after the block it was decreased in 26.92% and normal in 73.08% of the cats. None of the cats had an increased or absent reflex. Regarding the presence of both reflexes before and after anesthetic block, there was no significant difference at 1% ( P = 0.013). Conclusions and relevance The extensor carpi radialis and cranial tibial reflexes in cats are not strictly myotatic reflexes, as they are independent of the reflex arc, and may be idiomuscular responses. Therefore, they are not reliable for neurologic examination in this species.

  4. Landing strategies focusing on the control of tibial rotation in the initial contact period of one-leg forward hops.

    PubMed

    Chen, W-L; Chen, Y-T; Huang, S-Y; Yang, C-Y; Wu, C-D; Chang, C-W

    2017-08-01

    Anterior cruciate ligament (ACL) reconstruction (ACLR) surgeries successfully restore anterior tibial translation but not tibial rotation. This study aimed to explore landing strategies focusing on the control of tibial rotation at landing when the ACL is most vulnerable. Three groups of male subjects (50 ACLRs, 26 basketball players, and 31 controls) participated in one-leg forward hop tests for determining the tibial rotatory landing strategies adopted during the initial landing phase. The differences in knee kinematics and muscle activities between internal and external tibial rotatory (ITR, ETR) landing strategies were examined. A higher proportion of basketball players (34.6%) were found to adopt ITR strategies (controls: 6.5%), exhibiting significantly greater hopping distance and knee strength. After adjusting for hopping distance, subjects adopting ITR strategies were found to hop faster with straighter knees at foot contact and with greater ITR and less knee adduction angular displacement during the initial landing phase. However, significantly greater angular displacement in knee flexion, greater medial hamstring activities, and greater co-contraction index of hamstrings and medial knee muscles were also found during initial landing. Our results support the importance of the recruitments of medial hamstrings or the local co-contraction in assisting the rotatory control of the knee during initial landing for avoiding ACL injuries. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Significant RF-EMF and thermal levels observed in a computational model of a person with a tibial plate for grounded 40 MHz exposure.

    PubMed

    McIntosh, Robert L; Iskra, Steve; Anderson, Vitas

    2014-05-01

    Using numerical modeling, a worst-case scenario is considered when a person with a metallic implant is exposed to a radiofrequency (RF) electromagnetic field (EMF). An adult male standing on a conductive ground plane was exposed to a 40 MHz vertically polarized plane wave field, close to whole-body resonance where maximal induced current flows are expected in the legs. A metal plate (50-300 mm long) was attached to the tibia in the left leg. The findings from this study re-emphasize the need to ensure compliance with limb current reference levels for exposures near whole-body resonance, and not just rely on compliance with ambient electric (E) and magnetic (H) field reference levels. Moreover, we emphasize this recommendation for someone with a tibial plate, as failure to comply may result in significant tissue damage (increases in the localized temperature of 5-10 °C were suggested by the modeling for an incident E-field of 61.4 V/m root mean square (rms)). It was determined that the occupational reference level for limb current (100 mA rms), as stipulated in the 1998 guidelines of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), is satisfied if the plane wave incident E-field levels are no more than 29.8 V/m rms without an implant and 23.4 V/m rms for the model with a 300 mm implant. © 2014 Wiley Periodicals, Inc.

  6. Trampoline fracture of the proximal tibial metaphysis in children may not progress into valgus: a report of seven cases and a brief review.

    PubMed

    Kakel, R

    2012-06-01

    Fracture of the proximal tibial metaphysis in children is a rare injury but notorious for carrying the risk of subsequent valgus deformity of the tibia. Trampoline-caused fracture of the proximal tibial metaphysis in children may not progress into valgus. We followed up six children who collectively sustained seven fractures of the proximal tibial metaphysis while trampolining with other heavier and/or older children. Initial and follow-up x-rays were reviewed by an orthopaedic surgeons and two radiologists. None of the patients developed valgus deformity with follow-up. Trampoline is associated with a specific type of injury to the proximal tibia when children are trampolining with other heavier children even without falling off the trampoline. This fracture is linear and complete, often non-displaced. Unlike "other" proximal tibial metaphyseal fractures, trampoline-associated proximal tibial metaphysical fracture in children is not associated with a risk of subsequent valgus deformity. Level 4. case series. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  7. Anatomy, function, and pathophysiology of the posterior tibial tendon.

    PubMed

    Smith, C F

    1999-07-01

    The posterior tibial tendon is vital for the structure and function of the foot and ankle. Dysfunction of the tendon can be debilitating and devastating. In recent years, much attention had been directed toward the diagnosis and treatment of PTTD. To properly diagnose and devise an appropriate treatment regimen, the anatomy, function, and pathophysiology associated with PTTD need to be thoroughly understood.

  8. Leg Muscle Usage on Tibial Elasticity During Running

    DTIC Science & Technology

    2005-01-01

    relative risk of forefoot versus heel- strike running. In summary, there is no evidence in the literature that either study arm is at more risk than...tested in TSF, or even studied in runners. These basic validation studies will determine if modulators of tibial stress, .such as heel- strike mechanics...the other for acute injuries, although it was agreed that forefoot runners will be periodically evaluated for injuries to the Achilles tendon. After

  9. Multiple Tibial Insufficiency Fractures in the Same Tibia

    PubMed Central

    Defoort, Saartje; Mertens, Peter

    2011-01-01

    Stress fractures were first described by Briethaupt in 1855. Since then, there have been many discussions in the literature concerning stress fractures, which have been described in both weight-bearing and non-weight-bearing bones. Currently, the tibia is the most frequent location, but multiple stress fractures in the same tibia are rare. This paper presents an unusual case of a 60-year-old woman with multiple tibial stress fractures of spontaneous onset. PMID:23569673

  10. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    PubMed

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  11. Off-plane x-ray reflection grating fabrication

    NASA Astrophysics Data System (ADS)

    Peterson, Thomas J.; DeRoo, Casey T.; Marlowe, Hannah; McEntaffer, Randall L.; Miles, Drew M.; Tutt, James H.; Schultz, Ted B.

    2015-09-01

    Off-plane X-ray diffraction gratings with precision groove profiles at the submicron scale will be used in next generation X-ray spectrometers. Such gratings will be used on a current NASA suborbital rocket mission, the Off-plane Grating Rocket Experiment (OGRE), and have application for future grating missions. The fabrication of these gratings does not come without challenges. High performance off-plane gratings must be fabricated with precise radial grating patterns, optically at surfaces, and specific facet angles. Such gratings can be made using a series of common micro-fabrication techniques. The resulting process is highly customizable, making it useful for a variety of different mission architectures. In this paper, we detail the fabrication method used to produce high performance off-plane gratings and report the results of a preliminary qualification test of a grating fabricated in this manner. The grating was tested in the off-plane `Littrow' configuration, for which the grating is most efficient for a given diffraction order, and found to achieve 42% relative efficiency in the blaze order with respect to all diffracted light.

  12. Few-layered MnO2/SWCNT hybrid in-plane supercapacitor with high energy density

    NASA Astrophysics Data System (ADS)

    Dutta, Shibsankar; Pal, Shreyasi; De, Sukanta

    2018-05-01

    In this present work we have synthesized few layered MnO2 nanosheets by mixed solvent exfoliation process for the application as electrode material of in-plane supercapacitor. The Structure and surface morphology of the as prepared samples are characterized by Raman, Transmission electron microscopy and Scanning electron microscopy. The patterns of the hybrids were directly fabricated by (50: 50 wt %) mixture of MnO2 and SWCNT dispersions with the help of a customized mask, and directly transferred onto a flexible PET substrate. Remarkably, the prepared in-plane supercapacitors deliver high energy density of 2.62mWh/cm2. Furthermore, our supercapacitors shows exceptional flexibility and stable performance under bending conditions

  13. Aetiology and mechanisms of injury in medial tibial stress syndrome: Current and future developments

    PubMed Central

    Franklyn, Melanie; Oakes, Barry

    2015-01-01

    Medial tibial stress syndrome (MTSS) is a debilitating overuse injury of the tibia sustained by individuals who perform recurrent impact exercise such as athletes and military recruits. Characterised by diffuse tibial anteromedial or posteromedial surface subcutaneous periostitis, in most cases it is also an injury involving underlying cortical bone microtrauma, although it is not clear if the soft tissue or cortical bone reaction occurs first. Nuclear bone scans and magnetic resonance imaging (MRI) can both be used for the diagnosis of MTSS, but the patient’s history and clinical symptoms need to be considered in conjunction with the imaging findings for a correct interpretation of the results, as both imaging modalities have demonstrated positive findings in the absence of injury. However, MRI is rapidly becoming the preferred imaging modality for the diagnosis of bone stress injuries. It can also be used for the early diagnosis of MTSS, as the developing periosteal oedema can be identified. Retrospective studies have demonstrated that MTSS patients have lower bone mineral density (BMD) at the injury site than exercising controls, and preliminary data indicates the BMD is lower in MTSS subjects than tibial stress fracture (TSF) subjects. The values of a number of tibial geometric parameters such as cross-sectional area and section modulus are also lower in MTSS subjects than exercising controls, but not as low as the values in TSF subjects. Thus, the balance between BMD and cortical bone geometry may predict an individual's likelihood of developing MTSS. However, prospective longitudinal studies are needed to determine how these factors alter during the development of the injury and to find the detailed structural cause, which is still unknown. Finite element analysis has recently been used to examine the mechanisms involved in tibial stress injuries and offer a promising future tool to understand the mechanisms involved in MTSS. Contemporary accurate diagnosis

  14. Aetiology and mechanisms of injury in medial tibial stress syndrome: Current and future developments.

    PubMed

    Franklyn, Melanie; Oakes, Barry

    2015-09-18

    Medial tibial stress syndrome (MTSS) is a debilitating overuse injury of the tibia sustained by individuals who perform recurrent impact exercise such as athletes and military recruits. Characterised by diffuse tibial anteromedial or posteromedial surface subcutaneous periostitis, in most cases it is also an injury involving underlying cortical bone microtrauma, although it is not clear if the soft tissue or cortical bone reaction occurs first. Nuclear bone scans and magnetic resonance imaging (MRI) can both be used for the diagnosis of MTSS, but the patient's history and clinical symptoms need to be considered in conjunction with the imaging findings for a correct interpretation of the results, as both imaging modalities have demonstrated positive findings in the absence of injury. However, MRI is rapidly becoming the preferred imaging modality for the diagnosis of bone stress injuries. It can also be used for the early diagnosis of MTSS, as the developing periosteal oedema can be identified. Retrospective studies have demonstrated that MTSS patients have lower bone mineral density (BMD) at the injury site than exercising controls, and preliminary data indicates the BMD is lower in MTSS subjects than tibial stress fracture (TSF) subjects. The values of a number of tibial geometric parameters such as cross-sectional area and section modulus are also lower in MTSS subjects than exercising controls, but not as low as the values in TSF subjects. Thus, the balance between BMD and cortical bone geometry may predict an individual's likelihood of developing MTSS. However, prospective longitudinal studies are needed to determine how these factors alter during the development of the injury and to find the detailed structural cause, which is still unknown. Finite element analysis has recently been used to examine the mechanisms involved in tibial stress injuries and offer a promising future tool to understand the mechanisms involved in MTSS. Contemporary accurate diagnosis

  15. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  16. Which Surgical Treatment for Open Tibial Shaft Fractures Results in the Fewest Reoperations? A Network Meta-analysis.

    PubMed

    Foote, Clary J; Guyatt, Gordon H; Vignesh, K Nithin; Mundi, Raman; Chaudhry, Harman; Heels-Ansdell, Diane; Thabane, Lehana; Tornetta, Paul; Bhandari, Mohit

    2015-07-01

    shaft fractures. Moderate confidence evidence showed that unreamed nailing may reduce the likelihood of reoperation compared with external fixation (network odds ratio [OR], 0.38; 95% CI, 0.23-0.62; p < 0.05), although not necessarily compared with reamed nailing (direct OR, 0.74; 95% CI, 0.45-1.24; p = 0.25). Only low- or very low-quality evidence informed the primary outcome for other treatment comparisons, such as those involving internal plate fixation, Ilizarov external fixation, and Ender nailing. Method ranking based on reoperation data showed that unreamed nailing had the highest probability of being the best treatment, followed by reamed nailing, external fixation, and plate fixation. CIs around pooled estimates of malunion and infection risk were very wide, and therefore no conclusive results could be made based on these data. Current evidence suggests that intramedullary nailing may be superior to other fixation strategies for open tibial shaft fractures. Use of unreamed nails over reamed nails also may be advantageous in the setting of open fractures, but this remains to be confirmed. Unfortunately, these conclusions are based on trials that have had high risk of bias and poor precision. Larger and higher-quality head-to-head randomized controlled trials are required to confirm these conclusions and better inform clinical decision-making. Level I, therapeutic study.

  17. [Closing wedge osteotomy of the tibial head in treatment of single compartment arthrosis].

    PubMed

    Jakob, R P; Jacobi, M

    2004-02-01

    Closing wedge high tibial osteotomy is an efficient method for the treatment of medial osteoarthritis of the knee. Prerequisites of successful surgery are proper indication and planning as well as the understanding of biomechanics and pathophysiology. The technique of osteotomy to choose (opening or closing wedge) depends on the type of malalignment and on additional pathologies. The surgical technique demands high precision to realize the planned correction and to avoid complications. Implants with angular stability provide advantages compared to traditional implants. Correct indication and surgical technique results in a desirable follow-up, which often lasts for at least 10 years. The effect on the prognosis of the young patient with cartilage damage is still unclear.

  18. Three-dimensional knee motion before and after high tibial osteotomy for medial knee osteoarthritis.

    PubMed

    Takemae, Takashi; Omori, Go; Nishino, Katsutoshi; Terajima, Kazuhiro; Koga, Yoshio; Endo, Naoto

    2006-11-01

    High tibial osteotomy (HTO) is an established surgical option for treating medial knee osteoarthritis. HTO moves the mechanical load on the knee joint from the medial compartment to the lateral compartment by changing the leg alignment, but the effects of the operation remain unclear. The purpose of this study was to evaluate the change in three-dimensional knee motion before and after HTO, focusing on lateral thrust and screw home movement, and to investigate the relationship between the change in knee motion and the clinical results. A series of 19 patients with medial knee osteoarthritis who had undergone HTO were evaluated. We performed a clinical assessment, radiological evaluation, and motion analysis at 2.4 years postoperatively. The clinical assessment was performed using the Japanese Orthopaedic Association knee score. The score was significantly improved in all patients after operation. Motion analysis revealed that lateral thrust, which was observed in 18 of the 20 knees before operation, was reduced to 7 knees after operation. Regarding active terminal extension of the knee, three patterns of rotational movement were observed before operation: screw home movement (external rotation), reverse screw home movement (internal rotation), and no rotation. By contrast, after operation, only reverse screw home movement and no rotation were observed; the screw home movement disappeared in all patients. In the knees with reverse screw home movement after operation, the preoperative score was significantly lower than those in the knees with no rotation after operation. Kinetically, HTO was useful for suppressing lateral thrust in medial knee osteoarthritis, although the rotational movement of the knee joint was unchanged.

  19. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?

    PubMed

    Sangeux, Morgan; Mahy, Jessica; Graham, H Kerr

    2014-01-01

    Informed clinical decision making for femoral and/or tibial de-rotation osteotomies requires accurate measurement of patient function through gait analysis and anatomy through physical examination of bony torsions. Validity of gait analysis has been extensively studied; however, controversy remains regarding the accuracy of physical examination measurements of femoral and tibial torsion. Comparison between CT-scans and physical examination measurements of femoral neck anteversion (FNA) and external tibial torsion (ETT) were retrospectively obtained for 98 (FNA) and 64 (ETT) patients who attended a tertiary hospital for instrumented gait analysis between 2007 and 2010. The physical examination methods studied for femoral neck anteversion were the trochanteric prominence angle test (TPAT) and the maximum hip rotation arc midpoint (Arc midpoint) and for external tibial torsion the transmalleolar axis (TMA). Results showed that all physical examination measurements statistically differed to the CT-scans (bias(standard deviation): -2(14) for TPAT, -10(12) for Arc midpoint and -16(9) for TMA). Bland and Altman plots showed that method disagreements increased with increasing bony torsions in all cases but notably for TPAT. Regression analysis showed that only TMA and CT-scan measurement of external tibial torsion demonstrated good (R(2)=57%) correlation. Correlations for both TPAT (R(2)=14%) and Arc midpoint (R(2)=39%) with CT-scan measurements of FNA were limited. We conclude that physical examination should be considered as screening techniques rather than definitive measurement methods for FNA and ETT. Further research is required to develop more accurate measurement methods to accompany instrumented gait analysis. Copyright © 2013. Published by Elsevier B.V.

  20. Significant effect of the posterior tibial slope and medial/lateral ligament balance on knee flexion in total knee arthroplasty.

    PubMed

    Fujimoto, Eisaku; Sasashige, Yoshiaki; Masuda, Yasuji; Hisatome, Takashi; Eguchi, Akio; Masuda, Tetsuo; Sawa, Mikiya; Nagata, Yoshinori

    2013-12-01

    The intra-operative femorotibial joint gap and ligament balance, the predictors affecting these gaps and their balances, as well as the postoperative knee flexion, were examined. These factors were assessed radiographically after a posterior cruciate-retaining total knee arthroplasty (TKA). The posterior condylar offset and posterior tibial slope have been reported as the most important intra-operative factors affecting cruciate-retaining-type TKAs. The joint gap and balance have not been investigated in assessments of the posterior condylar offset and the posterior tibial slope. The femorotibial gap and medial/lateral ligament balance were measured with an offset-type tensor. The femorotibial gaps were measured at 0°, 45°, 90° and 135° of knee flexion, and various gap changes were calculated at 0°-90° and 0°-135°. Cruciate-retaining-type arthroplasties were performed in 98 knees with varus osteoarthritis. The 0°-90° femorotibial gap change was strongly affected by the posterior condylar offset value (postoperative posterior condylar offset subtracted by the preoperative posterior condylar offset). The 0°-135° femorotibial gap change was significantly correlated with the posterior tibial slope and the 135° medial/lateral ligament balance. The postoperative flexion angle was positively correlated with the preoperative flexion angle, γ angle and the posterior tibial slope. Multiple-regression analysis demonstrated that the preoperative flexion angle, γ angle, posterior tibial slope and 90° medial/lateral ligament balance were significant independent factors for the postoperative knee flexion angle. The flexion angle change (postoperative flexion angle subtracted by the preoperative flexion angle) was also strongly correlated with the preoperative flexion angle, posterior tibial slope and 90° medial/lateral ligament balance. The postoperative flexion angle is affected by multiple factors, especially in cruciate-retaining-type TKAs. However, it is

  1. Study on mechanical properties of steel honeycomb panel three-point bending specimen under in-plane and out-plane transverse dynamic impact load

    NASA Astrophysics Data System (ADS)

    Zou, Guangping; Chang, Zhongliang; Xia, Xingyou; Zhang, Xueyi

    2010-03-01

    The metal honeycomb material has high strength and high stiffness, as a high-performance sandwich panel, it is an ideal lightweight structural material, and widely used in aviation, aerospace, shipbuilding and other fields. In this paper, the improved SHPB instrument is used for testing the in-plane and out-plane mechanical properties of the steel honeycomb panel three-point bending specimen, and also compare the results with the static in-plane and out-plane three-point bending experiments results which is tested by the INSTRON 4505 electronic universal testing machine, and then study the mechanical properties of the steel honeycomb panel three-point bending specimen under transverse dynamic impact load. From the results it can be see that, for the out-plane three point bending experiment, L direction mechanical properties is better than the W direction, and the honeycomb core play an important role during the specimen deformation, while for the in-plane three point bending experiment, the honeycomb core mechanical role is not distinctness.

  2. Effect of tibial positioning on the diagnosis of posterolateral rotatory instability in the posterior cruciate ligament-deficient knee.

    PubMed

    Strauss, Eric J; Ishak, Charbel; Inzerillo, Christopher; Walsh, Michael; Yildirim, Gokce; Walker, Peter; Jazrawi, Laith; Rosen, Jeffrey

    2007-08-01

    To determine whether positioning of the tibia affects the degree of tibial external rotation seen during a dial test in the posterior cruciate ligament (PCL)-posterolateral corner (PLC)-deficient knee. Laboratory investigation. Biomechanics laboratory. An anterior force applied to the tibia in the combined PCL-PLC-deficient knee will yield increased tibial external rotation during a dial test. The degree of tibial external rotation was measured with 5 Nm of external rotation torque applied to the tibia at both 30 degrees and 90 degrees of knee flexion. Before the torque was applied, an anterior force, a posterior force, or neutral (normal, reduced control) force was applied to the tibia. External rotation measurements were repeated after sequential sectioning of the PCL, the posterolateral structures and the fibular collateral ligament (FCL). Baseline testing of the intact specimens demonstrated a mean external rotation of 18.6 degrees with the knee flexed to 30 degrees (range 16.1-21.0 degrees ), and a mean external rotation of 17.3 degrees with the knee flexed to 90 degrees (range 13.8-20.0 degrees ). Sequential sectioning of the PCL, popliteus and popliteofibular ligament, and the FCL led to a significant increase in tibial external rotation compared with the intact knee for all testing scenarios. After sectioning of the popliteus and popliteofibular ligament, the application of an anterior force during testing led to a mean tibial external rotation that was 5 degrees greater than during testing in the neutral position and 7.5 degrees greater than during testing with a posterior force. In the PCL, popliteus/popliteofibular ligament and FCL-deficient knee, external rotation was 9 degrees and 12 degrees greater with the application of an anterior force during testing compared with neutral positioning and the application of a posterior force, respectively. An anterior force applied to the tibia during the dial test in a combined PCL-PLC-injured knee increased the

  3. Neurofibromin Deficiency-Associated Transcriptional Dysregulation Suggests a Novel Therapy for Tibial Pseudoarthrosis in NF1

    PubMed Central

    Paria, Nandina; Cho, Tae-Joon; Choi, In Ho; Kamiya, Nobuhiro; Kayembe, Kay; Mao, Rong; Margraf, Rebecca L.; Obermosser, Gerlinde; Oxendine, Ila; Sant, David W.; Song, Mi Hyun; Stevenson, David A.; Viskochil, David H.; Wise, Carol A.; Kim, Harry K.W.; Rios, Jonathan J

    2014-01-01

    Neurofibromatosis type 1 (NF1) is an autosomal dominant disease caused by mutations in NF1. Among the earliest manifestations is tibial pseudoarthrosis and persistent nonunion after fracture. To further understand the pathogenesis of pseudoarthrosis and the underlying bone remodeling defect, pseudoarthrosis tissue and cells cultured from surgically resected pseudoarthrosis tissue from NF1 individuals were analyzed using whole-exome and whole-transcriptome sequencing as well as genomewide microarray analysis. Genomewide analysis identified multiple genetic mechanisms resulting in somatic bi-allelic NF1 inactivation; no other genes with recurring somatic mutations were identified. Gene expression profiling identified dysregulated pathways associated with neurofibromin deficiency, including phosphoinosital-3-kinase (PI3K) and mitogen-activated protein kinase (MAPK) signaling pathways. Unlike aggressive NF1-associated malignancies, tibial pseudoarthrosis tissue does not harbor a high frequency of somatic mutations in oncogenes or other tumor-suppressor genes, such as p53. However, gene expression profiling indicates pseudoarthrosis tissue has a tumor-promoting transcriptional pattern, despite lacking tumorigenic somatic mutations. Significant over-expression of specific cancer-associated genes in pseudoarthrosis highlights a potential for receptor tyrosine kinase inhibitors to target neurofibromin-deficient pseudoarthrosis and promote proper bone remodeling and fracture healing. PMID:24932921

  4. Tibial avulsion fracture of the posterior root of the medial meniscus in a skeletally-immature child - a case report.

    PubMed

    Matava, Matthew J; Kim, Young-Mo

    2011-01-01

    It has been theorized that a traumatic tibial avulsion fracture of the posterior root of the medial meniscus (MM) is the cause of the so-called meniscus ossicle (MO). We report the delayed appearance of a tibial avulsion fracture of the posterior root of the MM after a valgus, twisting injury in a 12-year-old boy with open physes. Magnetic resonance imaging (MRI) scans performed 3 days after the injury did not demonstrate a definitive tibial avulsion fracture of the posterior root of the MM; whereas, a repeat MRI for 3 months post-injury did. Medial extrusion of the MM was also noted on the 3 month MRI. Arthroscopic reattachment of the avulsed posterior root of the MM using a trans-physeal nonabsorbable suture tied over a proximal tibia staple was performed. Follow-up MRI at 6 months postoperatively demonstrated healing of the tibial avulsion fracture of the posterior root of the MM in an anatomic position. The patient had a complete resolution of symptoms and there was no angular deformity or limb-length discrepancy at 2 years postoperatively. To our knowledge, this is the first report describing a tibial avulsion fracture of the posterior root of the MM in a skeletally-immature patient successfully treated by a trans-physeal arthroscopic suture. This case also illustrates the development of the MO of the posterior root of the MM. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Prevention of arthrofibrosis after arthroscopic screw fixation of tibial spine fracture in children and adolescents.

    PubMed

    Parikh, Shital N; Myer, David; Eismann, Emily A

    2014-01-01

    Arthrofibrosis is a major complication of tibial spine fracture treatment in children, potentially resulting in knee pain, quadriceps weakness, altered gait, decreased function, inability to return to sports, and long-term osteoarthritis. Thus, prevention rather than treatment of arthrofibrosis is desirable. The purpose of this study was to evaluate an aggressive postoperative rehabilitation and early intervention approach to prevent permanent arthrofibrosis after tibial spine fracture treatment and to compare epiphyseal and transphyseal screws for fixation. A consecutive series of 24 patients younger than age 18 with displaced type II and III tibial spine fractures who underwent arthroscopic reduction and screw fixation between 2006 and 2011 were retrospectively reviewed. Final range of motion was compared between patients with epiphyseal (n=12) and transphyseal (n=9) screws. One-third (4 of 12) of patients with epiphyseal screws underwent arthroscopic debridement and screw removal approximately 3 months postoperatively; 3 patients lacked 5° to 15° of extension, 1 experienced pain with extension, and 1 had radiographic evidence of screw pullout, loss of reduction, and resultant malunion. In the transphyseal screw group, 3 patients had 10° loss of extension, and all corrected after arthroscopic debridement and screw removal. The two groups did not significantly differ in time to hardware removal or return to sports or final range of motion. No growth disturbances were identified in patients after transphyseal screw removal. An aggressive approach of postoperative rehabilitation and early intervention after arthroscopic reduction and screw fixation of tibial spine fractures in children was successful in preventing permanent arthrofibrosis.

  6. Rare case of tibial hemimelia, preaxial polydactyly, and club foot

    PubMed Central

    Granite, Guinevere; Herzenberg, John E; Wade, Ronald

    2016-01-01

    A seven-month old female presented with left tibial hemimelia (or congenital tibial aplasia; Weber type VIIb, Jones et al type 1a), seven-toed preaxial polydactyly, and severe club foot (congenital talipes equinovarus). Definitive amputation surgery disarticulated the lower limb at the knee. This case report describes the anatomical findings of a systematic post-amputation examination of the lower limb’s superficial dissection, X-rays, and computed tomography (CT) scans. From the X-rays and CT scans, we found curved and overlapping preaxial supernumerary toes, hypoplastic first metatarsal, lack of middle and distal phalanges in one supernumerary toe, three tarsal bones, hypoplastic middle phalanx and no distal phalanx for fourth toe, and no middle or distal phalanges for fifth toe. The fibula articulated with the anteromedial calcaneus and the tibia was completely absent. We identified numerous muscles and nerves in the superficial dissection that are described in the results section of the case report. Due to the rarity of this combination of anatomical findings, descriptions of such cases are very infrequent in the literature. PMID:28035313

  7. Rare case of tibial hemimelia, preaxial polydactyly, and club foot.

    PubMed

    Granite, Guinevere; Herzenberg, John E; Wade, Ronald

    2016-12-16

    A seven-month old female presented with left tibial hemimelia (or congenital tibial aplasia; Weber type VIIb, Jones et al type 1a), seven-toed preaxial polydactyly, and severe club foot (congenital talipes equinovarus). Definitive amputation surgery disarticulated the lower limb at the knee. This case report describes the anatomical findings of a systematic post-amputation examination of the lower limb's superficial dissection, X-rays, and computed tomography (CT) scans. From the X-rays and CT scans, we found curved and overlapping preaxial supernumerary toes, hypoplastic first metatarsal, lack of middle and distal phalanges in one supernumerary toe, three tarsal bones, hypoplastic middle phalanx and no distal phalanx for fourth toe, and no middle or distal phalanges for fifth toe. The fibula articulated with the anteromedial calcaneus and the tibia was completely absent. We identified numerous muscles and nerves in the superficial dissection that are described in the results section of the case report. Due to the rarity of this combination of anatomical findings, descriptions of such cases are very infrequent in the literature.

  8. Economics of All-Polyethylene Versus Metal-Backed Tibial Prosthesis Designs.

    PubMed

    Chambers, Monique C; El-Othmani, Mouhanad M; Sayeed, Zain; Anoushiravani, Afshin; Schnur, Anne-Kathrin; Mihalko, William M; Saleh, Khaled J

    2016-05-01

    With the large number of total knee arthroplasties being performed and expectations that these numbers will be on the rise over the coming decades, efforts to provide cost-efficient care are of greater interest. The preferred design of knee arthroplasty implants has changed over time, with the original all-polyethylene tibial (APT) design being replaced by metal-backed tibial (MBT) components, as well as more recent considerations of newer APT designs. Modern APT components have been shown to have similar or superior outcomes than MBT components. Despite their limitations, APT components can be used to reduce the economic burden to the provider, medical institution, and health care system as a whole. There is a paucity of evidence-based literature directly comparing the cost associated with APT and MBT components. The purpose of this report is to review the literature to assess the available data regarding direct and indirect costs of both designs so that orthopedic surgeons can account for economic differences in everyday practice. [Orthopedics. 2016; 39(3):S61-S66.]. Copyright 2016, SLACK Incorporated.

  9. Low power, highly linear output buffer. [for infrared focal plane arrays

    NASA Technical Reports Server (NTRS)

    Foley, D.; Butler, N.; Stobie, J.

    1992-01-01

    A class AB CMOS output buffer has been designed for use on an IR focal plane array. Given the requirements for power dissipation and load capacitance a class A output, such as a source follower, would be unsuitable. The approach taken uses a class AB amplifier configured as a charge integrator. Thus it converts a charge packet in the focal plane multiplexer to a voltage which is then the output of the focal plane. With a quiescent current of 18 micro-a and a load capacitance of 100 pf, the amplifier has an open loop unity gain bandwidth of 900 khz. Integral nonlinearity is better than .03 percent over 5.5 volts when run with VDD-VSS = 6v.

  10. Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The 'fix and shift' technique.

    PubMed

    Ramasamy, P R

    2017-01-01

    Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

  11. Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound.

    PubMed

    Leung, Kwok-Sui; Lee, Wing-Sze; Tsui, Hon-For; Liu, Paul Po-Lung; Cheung, Wing-Hoi

    2004-03-01

    A clinical study was conducted to investigate the effect of low-intensity pulsed ultrasound (US) stimulation (LIPUS) on the healing of complex tibial fractures. Thirty complex tibial fractures were randomly assigned to the treatment with LIPUS (n = 16) or by a dummy machine (sham-exposed: n = 14). The fractures were immobilized by either internal or external fixations according to the clinical indications. LIPUS was given 20 min/day for 90 days. Fracture healing was monitored by clinical, radiological, densitometric and biochemical assessments. The LIPUS-treated group showed statistically significantly better healing, as demonstrated by all assessments. Complications were minimal in the LIPUS group. There were two cases of delayed union, with one in each group. There were two cases of infection in the control group. The delayed-union cases were subsequently treated by LIPUS and the infection cases were treated with standard protocol. Fracture healing in these patients was again treated by LIPUS.

  12. Defining the Lower Limit of a "Critical Bone Defect" in Open Diaphyseal Tibial Fractures.

    PubMed

    Haines, Nikkole M; Lack, William D; Seymour, Rachel B; Bosse, Michael J

    2016-05-01

    To determine healing outcomes of open diaphyseal tibial shaft fractures treated with reamed intramedullary nailing (IMN) with a bone gap of 10-50 mm on ≥50% of the cortical circumference and to better define a "critical bone defect" based on healing outcome. Retrospective cohort study. Forty patients, age 18-65, with open diaphyseal tibial fractures with a bone gap of 10-50 mm on ≥50% of the circumference as measured on standard anteroposterior and lateral postoperative radiographs treated with IMN. IMN of an open diaphyseal tibial fracture with a bone gap. Level-1 trauma center. Healing outcomes, union or nonunion. Forty patients were analyzed. Twenty-one (52.5%) went on to nonunion and nineteen (47.5%) achieved union. Radiographic apparent bone gap (RABG) and infection were the only 2 covariates predicting nonunion outcome (P = 0.046 for infection). The RABG was determined by measuring the bone gap on each cortex and averaging over 4 cortices. Fractures achieving union had a RABG of 12 ± 1 mm versus 20 ± 2 mm in those going on to nonunion (P < 0.01). This remained significant when patients with infection were removed. Receiver operator characteristic analysis demonstrated that RABG was predictive of outcome (area under the curve of 0.79). A RABG of 25 mm was the statistically optimal threshold for prediction of healing outcome. Patients with open diaphyseal tibial fractures treated with IMN and a <25 mm RABG have a reasonable probability of achieving union without additional intervention, whereas those with larger gaps have a higher probability of nonunion. Research investigating interventions for RABGs should use a predictive threshold for defining a critical bone defect that is associated with greater than 50% risk of nonunion without supplementary treatment. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. [Balloon osteoplasty as reduction technique in the treatment of tibial head fractures].

    PubMed

    Freude, T; Kraus, T M; Sandmann, G H

    2015-10-01

    Tibial plateau fractures requiring surgery are severe injuries of the lower extremities. Depending on the fracture pattern, the age of the patient, the range of activity and the bone quality there is a broad variation in adequate treatment.  This article reports on an innovative treatment concept to address split depression fractures (Schatzker type II) and depression fractures (Schatzker type III) of the tibial head using the balloon osteoplasty technique for fracture reduction. Using the balloon technique achieves a precise and safe fracture reduction. This internal osteoplasty combines a minimal invasive percutaneous approach with a gently rise of the depressed area and the associated protection of the stratum regenerativum below the articular cartilage surface. This article lights up the surgical procedure using the balloon technique in tibia depression fractures. Using the balloon technique a precise and safe fracture reduction can be achieved. This internal osteoplasty combines a minimally invasive percutaneous approach with a gentle raising of the depressed area and the associated protection of the regenerative layer below the articular cartilage surface. Fracture reduction by use of a tamper results in high peak forces over small areas, whereas by using the balloon the forces are distributed over a larger area causing less secondary stress to the cartilage tissue. This less invasive approach might help to achieve a better long-term outcome with decreased secondary osteoarthritis due to the precise and chondroprotective reduction technique.

  14. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    PubMed

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  15. High frequency coaxial pulse tube cryocoolers for cooling infrared focal plane arrays

    NASA Astrophysics Data System (ADS)

    Dang, Haizheng

    2010-11-01

    A survey is made about the development of high frequency coaxial PTCs. The coolers cover from 30 K to 200 K and the cooling power levels from hundreds of milliwatts to 10's W. Tests suggest that they have the potential to provide appropriate cooling for HgCdTe-based infrared focal plane arrays from near visible down to very long wave infrared region. The paper also discusses the efforts to realize space qualified cryocooler technologies.

  16. Flow-Through Free Fibula Osteocutaneous Flap in Reconstruction of Tibial Bone, Soft Tissue, and Main Artery Segmental Defects.

    PubMed

    Li, Zonghuan; Yu, Aixi; Qi, Baiwen; Pan, Zhenyu; Ding, Junhui

    2017-08-01

    The aim of this report was to present the use of flow-through free fibula osteocutaneous flap for the repair of complex tibial bone, soft tissue, and main artery segmental defects. Five patients with bone, soft tissue, and segmental anterior tibial artery defects were included. The lengths of injured tibial bones ranged from 4 to 7 cm. The sizes of impaired soft tissues were between 9 × 4 and 15 × 6 cm. The lengths of defect of anterior tibial artery segments ranged from 6 to 10 cm. Two patients had distal limb perfusion problems. Flow-through free fibula osteocutaneous flap was performed for all 5 patients. Patients were followed for 12 to 18 months. All wounds healed after 1-stage operation, and all flow-through flaps survived. The distal perfusion after vascular repair was normal in all patients. Superficial necrosis of flap edge was noted in 1 case. After the local debridement and partial thickness skin graft, the flap healed uneventfully, and the surgical operation did not increase injury to the donor site. Satisfactory bone union was achieved in all patients in 2 to 4 months postoperation. Enlargement of fibula graft was observed during follow-up from 12 to 18 months. The functions of adjacent joints were recovered, and all patients were able to walk normally. Flow-through free fibula osteocutaneous flap was shown to be an effective and efficient technique for repairing composite tibial bone, soft tissue, and main artery segmental defects. This 1-stage operation should be useful in clinical practice for the treatment of complex bone, soft tissue, and vessel defects.

  17. Pristine Basal- and Edge-Plane-Oriented Molybdenite MoS2 Exhibiting Highly Anisotropic Properties.

    PubMed

    Tan, Shu Min; Ambrosi, Adriano; Sofer, Zdenĕk; Huber, Štěpán; Sedmidubský, David; Pumera, Martin

    2015-05-04

    The layered structure of molybdenum disulfide (MoS2 ) is structurally similar to that of graphite, with individual sheets strongly covalently bonded within but held together through weak van der Waals interactions. This results in two distinct surfaces of MoS2 : basal and edge planes. The edge plane was theoretically predicted to be more electroactive than the basal plane, but evidence from direct experimental comparison is elusive. Herein, the first study comparing the two surfaces of MoS2 by using macroscopic crystals is presented. A careful investigation of the electrochemical properties of macroscopic MoS2 pristine crystals with precise control over the exposure of one plane surface, that is, basal plane or edge plane, was performed. These crystals were characterized thoroughly by AFM, Raman spectroscopy, X-ray photoelectron spectroscopy, voltammetry, digital simulation, and DFT calculations. In the Raman spectra, the basal and edge planes show anisotropy in the preferred excitation of E2g and A1g phonon modes, respectively. The edge plane exhibits a much larger heterogeneous electron transfer rate constant k(0) of 4.96×10(-5) and 1.1×10(-3)  cm s(-1) for [Fe(CN)6 ](3-/4-) and [Ru(NH3 )6 ](3+/2+) redox probes, respectively, compared to the basal plane, which yielded k(0) tending towards zero for [Fe(CN)6 ](3-/4-) and about 9.3×10(-4)  cm s(-1) for [Ru(NH3 )6 ](3+/2+) . The industrially important hydrogen evolution reaction follows the trend observed for [Fe(CN)6 ](3-/4-) in that the basal plane is basically inactive. The experimental comparison of the edge and basal planes of MoS2 crystals is supported by DFT calculations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Magneto-transport Characterization of Thin Film In-plane and Cross-plane Conductivity

    NASA Astrophysics Data System (ADS)

    Tang, Yang; Grayson, Matthew

    Thin films with highly anisotropic in-plane and cross-plane conductivities are widely used in devices, such as infrared emitters and detectors, and the proper magneto-transport characterization in both directions can reveal information about the doping density, impurities, carrier life times and band structure. This work introduces a novel method for deducing the complete anisotropic electrical conductivity tensor of such an anisotropic resistive layer atop a highly conducting bottom contact, which is a standard part of the device structure. Three strip-line contacts separated by a length scale comparable to the film thickness are applied atop the resistive thin film layer of interest, with the highly conducting back-plane as a back-contact. The potential distribution in the device is modeled, using both scaling and conformal transformation to minimize the calculated volume. As a proof of concept, triple strip-line devices for GaAs and GaAs/AlGaAs superlattice thin films are fabricated. To achieve narrow strip-line contacts with sub-micron scale widths, non-annealed Ni/Au contacts form ohmic contacts to a patterned n+-GaAs cap layer atop the anisotropic thin films. Preliminary experimental data will be presented as a validation of this method. Acknowledgment: Funded by AFOSR FA9550-15-1-0377 and AFOSR FA9550-15-1-0247.

  19. Tibial Inlay Press-fit Fixation Versus Interference Screw in Posterior Cruciate Ligament Reconstruction.

    PubMed

    Ettinger, Max; Büermann, Sarah; Calliess, Tilman; Omar, Mohamed; Krettek, Christian; Hurschler, Christof; Jagodzinski, Michael; Petri, Maximilian

    2013-01-01

    Reconstruction of the posterior cruciate ligament (PCL) by a tibial press-fit fixation of the patellar tendon with an accessory bone plug is a promising approach because no foreign materials are required. Until today, there is no data about the biomechanical properties of such press-fit fixations. The aim of this study was to compare the biomechanical qualities of a bone plug tibial inlay technique with the commonly applied interference screw of patellar tendon PCL grafts. Twenty patellar tendons including a bone block were harvested from ten human cadavers. The grafts were implanted into twenty legs of adult German country pigs. In group P, the grafts were attached in a press-fit technique with accessory bone plug. In group S, the grafts were fixed with an interference screw. Each group consisted of 10 specimens. The constructs were biomechanically analyzed in cyclic loading between 60 and 250 N for 500 cycles recording elongation. Finally, ultimate failure load and failure mode were analyzed. Ultimate failure load was 598.6±36.3 N in group P and 653.7±39.8 N in group S (not significant, P>0.05). Elongation during cyclic loading between the 1(st) and the 20(th) cycle was 3.4±0.9 mm for group P and 3.1±1 mm for group S. Between the 20(th) and the 500(th) cycle, elongation was 4.2±2.3 mm in group P and 2.5±0.9 mm in group S (not significant, P>0.05). This is the first study investigating the biomechanical properties of tibial press-fit fixation of the patellar tendon with accessory bone plug in posterior cruciate ligament reconstruction. The implant-free tibial inlay technique shows equal biomechanical characteristics compared to an interference screw fixation. Further in vivo studies are desirable to compare the biological behavior and clinical relevance of this fixation device.

  20. Utility of cement injection to stabilize split-depression tibial plateau fracture by minimally invasive methods: A finite element analysis.

    PubMed

    Belaid, D; Vendeuvre, T; Bouchoucha, A; Brémand, F; Brèque, C; Rigoard, P; Germaneau, A

    2018-05-08

    Treatment for fractures of the tibial plateau is in most cases carried out by stable fixation in order to allow early mobilization. Minimally invasive technologies such as tibioplasty or stabilization by locking plate, bone augmentation and cement filling (CF) have recently been used to treat this type of fracture. The aim of this paper was to determine the mechanical behavior of the tibial plateau by numerically modeling and by quantifying the mechanical effects on the tibia mechanical properties from injury healing. A personalized Finite Element (FE) model of the tibial plateau from a clinical case has been developed to analyze stress distribution in the tibial plateau stabilized by balloon osteoplasty and to determine the influence of the cement injected. Stress analysis was performed for different stages after surgery. Just after surgery, the maximum von Mises stresses obtained for the fractured tibia treated with and without CF were 134.9 MPa and 289.9 MPa respectively on the plate. Stress distribution showed an increase of values in the trabecular bone in the treated model with locking plate and CF and stress reduction in the cortical bone in the model treated with locking plate only. The computed results of stresses or displacements of the fractured models show that the cement filling of the tibial depression fracture may increase implant stability, and decrease the loss of depression reduction, while the presence of the cement in the healed model renders the load distribution uniform. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation

    PubMed Central

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-01-01

    Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890

  2. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    PubMed

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P < 0.05). The incision length in trial group was significantly shorter than that in control group (P < 0.05). Difference was not significant in operation time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for

  3. Frontal plane landing mechanics in high-arched compared with low-arched female athletes.

    PubMed

    Powell, Douglas W; Hanson, Nicholas J; Long, Benjamin; Williams, D S Blaise

    2012-09-01

    To examine ground reaction forces (GRFs); frontal plane hip, knee, and ankle joint angles; and moments in high-arched (HA) and low-arched (LA) athletes during landing. Experimental study. Controlled research laboratory. Twenty healthy female recreational athletes (10 HA and 10 LA). Athletes performed 5 barefoot drop landings from a height of 30 cm. Frontal plane ankle, knee, and hip joint angles (in degrees) at initial contact, peak vertical GRF, and peak knee flexion; peak ankle, knee, and hip joint moments in the frontal plane. Vertical GRF profiles were similar between HA and LA athletes (P = 0.78). The HA athletes exhibited significantly smaller peak ankle inversion angles than the LA athletes (P = 0.01) at initial contact. At peak vertical GRF, HA athletes had significantly greater peak knee (P = 0.01) and hip abduction angles than LA athletes (P = 0.02). There were no significant differences between HA and LA athletes in peak joint moments (hip: P = 0.68; knee: P = 0.71; ankle: P = 0.15). These findings demonstrate that foot type is associated with altered landing mechanics, which may underlie lower extremity injuries. The ankle-driven strategy previously reported in female athletes suggests that foot function may have a greater relationship with lower extremity injury than that in male athletes. Future research should address the interaction of foot type and gender during landing tasks.

  4. Atrophic, aseptic, tibial nonunion: how effective is modified Judet's osteoperiosteal decortication technique and buttress plating?

    PubMed

    Binod, Bijukachhe; Nagmani, Singh; Bigyan, Bhandari; Rakesh, John; Prashant, Adhikari

    2016-08-01

    Tibial nonunion is the most common nonunion encountered by the orthopedic surgeon. Repeated surgeries, cost, increased duration of hospital stay, disability, pain all contribute to the increased morbidity. Many methods have been used to treat nonunion of tibia with variable results and none of them are 100 % successful. Our objective was to determine the effectiveness of modification of Judet's decortication technique and buttress plating, without bone graft, in the treatment of aseptic, atrophic tibial nonunion. Also, to find the correlation between time of achieving union and time since injury to decortication. Ours is a retrospective study conducted at a Level I trauma center. A total of 35 cases of atrophic tibial nonunion, irrespective of the cause, was treated by modifying Judet's osteoperiosteal decortication and plating during the time period January 2006 to July 2013. Demographic data, range of motion, time of achieving union and clinico-radiological evaluation for union of fracture were included as main outcome measurements. Union was achieved in all cases with a mean duration of 8.34 months. Pain and stiffness of joints were not reported in any case on long-term follow-up and the patients had satisfactory range of motion. Implant removal was done in three cases after fracture union. Treatment of atrophic tibial nonunion is challenging and management of each nonunion has to be customized based on the biological and mechanical characteristics of the nonunion. Plating with osteoperiosteal decortication is an effective and simple technique, which in our hands has shown to result in 100 % union rates without the need of additional bone healing augmentation procedures like bone grafting. Level II.

  5. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    PubMed

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. 3D printed alendronate-releasing poly(caprolactone) porous scaffolds enhance osteogenic differentiation and bone formation in rat tibial defects.

    PubMed

    Kim, Sung Eun; Yun, Young-Pil; Shim, Kyu-Sik; Kim, Hak-Jun; Park, Kyeongsoon; Song, Hae-Ryong

    2016-09-29

    The aim of this study was to evaluate the in vitro osteogenic effects and in vivo new bone formation of three-dimensional (3D) printed alendronate (Aln)-releasing poly(caprolactone) (PCL) (Aln/PCL) scaffolds in rat tibial defect models. 3D printed Aln/PCL scaffolds were fabricated via layer-by-layer deposition. The fabricated Aln/PCL scaffolds had high porosity and an interconnected pore structure and showed sustained Aln release. In vitro studies showed that MG-63 cells seeded on the Aln/PCL scaffolds displayed increased alkaline phosphatase (ALP) activity and calcium content in a dose-dependent manner when compared with cell cultures in PCL scaffolds. In addition, in vivo animal studies and histologic evaluation showed that Aln/PCL scaffolds implanted in a rat tibial defect model markedly increased new bone formation and mineralized bone tissues in a dose-dependent manner compared to PCL-only scaffolds. Our results show that 3D printed Aln/PCL scaffolds are promising templates for bone tissue engineering applications.

  7. Reliable landmarks for precise topographical analyses of pathological structural changes of the ovine tibial plateau in 2-D and 3-D subspaces.

    PubMed

    Oláh, Tamás; Reinhard, Jan; Gao, Liang; Goebel, Lars K H; Madry, Henning

    2018-01-08

    Selecting identical topographical locations to analyse pathological structural changes of the osteochondral unit in translational models remains difficult. The specific aim of the study was to provide objectively defined reference points on the ovine tibial plateau based on 2-D sections of micro-CT images useful for reproducible sample harvesting and as standardized landmarks for landmark-based 3-D image registration. We propose 5 reference points, 11 reference lines and 12 subregions that are detectable macroscopically and on 2-D micro-CT sections. Their value was confirmed applying landmark-based rigid and affine 3-D registration methods. Intra- and interobserver comparison showed high reliabilities, and constant positions (standard errors < 1%). Spatial patterns of the thicknesses of the articular cartilage and subchondral bone plate were revealed by measurements in 96 individual points of the tibial plateau. As a case study, pathological phenomena 6 months following OA induction in vivo such as osteophytes and areas of OA development were mapped to the individual subregions. These new reference points and subregions are directly identifiable on tibial plateau specimens or macroscopic images, enabling a precise topographical location of pathological structural changes of the osteochondral unit in both 2-D and 3-D subspaces in a region-appropriate fashion relevant for translational investigations.

  8. Correlation between hindfoot joint three-dimensional kinematics and the changes of the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot.

    PubMed

    Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin

    2015-02-01

    The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site.

    PubMed

    Hirschmann, Michael T; Mathis, Dominic; Rasch, Helmut; Amsler, Felix; Friederich, Niklaus F; Arnold, Markus P

    2013-02-01

    SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. A consecutive series of knees (n=66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL

  10. Patient reported health related quality of life early outcomes at 12 months after surgically managed tibial plafond fracture.

    PubMed

    Bonato, Luke J; Edwards, Elton R; Gosling, Cameron McR; Hau, Raphael; Hofstee, Dirk Jan; Shuen, Alex; Gabbe, Belinda J

    2017-04-01

    Tibial plafond fractures represent a small but complex subset of fractures of the lower limb. The aim of this study was to describe the health related quality of life, pain and return to work outcomes 12 months following surgically managed tibial plafond fracture. The Victorian Orthopaedic Trauma Outcomes Registry (VOTOR) database was used to identify patients with tibial plafond fractures. All patients captured by VOTOR with a tibial plafond fracture between September 2003 and July 2009, were identified consecutively and comprised the initial cohort. The radiographs of all identified patients were classified using the AO/OTA fracture classification. A review of the included patient's medical records was performed. Data were collected on the injury event, management and complications. Outcomes at 12 months were prospectively collected by telephone interview and included return to work, a numerical rating scale for assessment of pain and the Short Form 12 (SF-12). There were 98 unilateral tibial plafond fractures; 91 fractures were managed operatively, 4 non-operatively and 3 underwent amputation. The 91 operatively managed patients were the focus of this study. A two-stage management approach, involving temporary external fixation, followed by definitive open reduction and internal fixation, was the most common operative treatment. The follow-up rate at 12 months was 70%. 57% had returned to work by 12 months post-injury, the median (IQR) pain score was 2 (0-5) and 27% reported moderate to severe persistent pain. Mean PCS-12 scores were significantly lower than Australian norms (p=0.99), 38.2 for males and 37.5 for females. The presence of persistent pain, loss of physical health and a low return to work rate highlights the profound impact of tibial plafond fractures on patients' lives. Although this study looked at the early 12 month results, it is expected these outcomes will continue to improve over time. Further studies, with larger patient numbers, must focus

  11. Functional outcome of tibial fracture with acute compartment syndrome and correlation to deep posterior compartment pressure.

    PubMed

    Goyal, Saumitra; Naik, Monappa A; Tripathy, Sujit Kumar; Rao, Sharath K

    2017-05-18

    To measure single baseline deep posterior compartment pressure in tibial fracture complicated by acute compartment syndrome (ACS) and to correlate it with functional outcome. Thirty-two tibial fractures with ACS were evaluated clinically and the deep posterior compartment pressure was measured. Urgent fasciotomy was needed in 30 patients. Definite surgical fixation was performed either primarily or once fasciotomy wound was healthy. The patients were followed up at 3 mo, 6 mo and one year. At one year, the functional outcome [lower extremity functional scale (LEFS)] and complications were assessed. Three limbs were amputated. In remaining 29 patients, the average times for clinical and radiological union were 25.2 ± 10.9 wk (10 to 54 wk) and 23.8 ± 9.2 wk (12 to 52 wk) respectively. Nine patients had delayed union and 2 had nonunion who needed bone grafting to augment healing. Most common complaint at follow up was ankle stiffness (76%) that caused difficulty in walking, running and squatting. Of 21 patients who had paralysis at diagnosis, 13 (62%) did not recover and additional five patients developed paralysis at follow-up. On LEFS evaluation, there were 14 patients (48.3%) with severe disability, 10 patients (34.5%) with moderate disability and 5 patients (17.2%) with minimal disability. The mean pressures in patients with minimal disability, moderate disability and severe disability were 37.8, 48.4 and 58.79 mmHg respectively ( P < 0.001). ACS in tibial fractures causes severe functional disability in majority of patients. These patients are prone for delayed union and nonunion; however, long term disability is mainly because of severe soft tissue contracture. Intra-compartmental pressure (ICP) correlates with functional disability; patients with relatively high ICP are prone for poor functional outcome.

  12. Impingement of the Mobile Bearing on the Lateral Wall of the Tibial Tray in Unicompartmental Knee Arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Shirakawa, Nobuyuki; Tanaka, Sakae

    2016-07-01

    Tilting of the mobile bearing relative to the tibial tray in the flexion position may result from the implantation of femoral components more laterally relative to tibial components during unicompartmental knee arthroplasty (UKA) using the Oxford Knee. The purpose of the present study was to compare femoral component positions after UKA using the phase 3 device and a novel device. We further evaluated the placement of the femoral components with the new device in the flexion position to determine the association with short-term prognosis. The location of femoral and tibial components in the flexion position of 38 knees implanted using the phase 3 device and 49 knees using a novel device was assessed at 1 year postoperatively using radiography of the proximal tibia and distal femur in the flexion position. The femoral component was implanted more laterally using the new device than using the phase 3 device in the flexion position (P = .012), which caused the impingement of the mobile bearing against the lateral wall of the tibial tray. After UKA using the new device, 10% of patients exhibited the tilting phenomenon of the mobile bearing because of the lateral implantation of the femoral implant. To prevent implantation of the femoral component too laterally using the new device during UKA, knee surgeons should set the drill guide more medially such that the center of the drill is aligned with the middle of the medial femoral condyle. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Solid-state curved focal plane arrays

    NASA Technical Reports Server (NTRS)

    Jones, Todd (Inventor); Nikzad, Shouleh (Inventor); Hoenk, Michael (Inventor)

    2010-01-01

    The present invention relates to curved focal plane arrays. More specifically, the present invention relates to a system and method for making solid-state curved focal plane arrays from standard and high-purity devices that may be matched to a given optical system. There are two ways to make a curved focal plane arrays starting with the fully fabricated device. One way, is to thin the device and conform it to a curvature. A second way, is to back-illuminate a thick device without making a thinned membrane. The thick device is a special class of devices; for example devices fabricated with high purity silicon. One surface of the device (the non VLSI fabricated surface, also referred to as the back surface) can be polished to form a curved surface.

  14. Evaluating the suitability of highly cross-linked and remelted materials for use in posterior stabilized knees.

    PubMed

    Huot, J Caitlin; Van Citters, Douglas W; Currier, John H; Currier, Barbara H; Mayor, Michael B; Collier, John P

    2010-11-01

    Posterior stabilized (PS) knee designs are a popular choice for cruciate sacrificing knee arthroplasty procedures. The introduction of PS inserts fabricated from highly cross-linked and remelted Ultra High Molecular Weight Polyethylene (UHMWPE) has recently generated concern as these materials have been shown to possess reduced mechanical properties. This study investigated whether highly cross-linked and remelted UHMWPE material (referred to as XRP) can be expected to perform similarly to historical gamma-air polyethylene, which has suffered few reported incidences of tibial post failure. Never-implanted gamma-air PS tibial inserts shelf-aged 14 years were examined and compared to XRP materials. Evaluation of oxidation levels, impact toughness, and fatigue strength demonstrated never-implanted gamma-air PS tibial inserts to possess nonuniform mechanical properties. Despite severe oxidation along the exterior of gamma-air tibial posts, comparatively low oxidation levels at the center of the tibial posts corresponded to sufficiently high mechanical properties. XRP material (75 kGy) showed superior impact toughness over shelf aged gamma-air material; however, tibial post fatigue testing demonstrated XRP material (100 kGy) to be less resistant to fatigue failure than historical gamma-air material. Results from this study indicate that XRP materials (100 kGy) may demonstrate an inferior resistance to tibial post failure than historical polyethylene. © 2010 Wiley Periodicals, Inc.

  15. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    PubMed

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  16. Total knee replacement with tibial tubercle osteotomy in rheumatoid patients with stiff knee.

    PubMed

    Eid, Ahmed Salem; Nassar, Wael Ahmed Mohamed; Fayyad, Tamer Abdelmeguid Mohamed

    2016-11-01

    Total knee arthroplasty (TKA) is a well-proven modality that can provide pain relief and restore mobility for rheumatoid arthritis (RA) patients with advanced joint destruction. Patellar ligament avulsion, especially in presence of poor bone quality and knee stiffness, is one of the special considerations that must be addressed in this unique population of patients. This study aimed to determine the functional results in a series of rheumatoid patients with stiff knee and end-stage joint destruction who underwent tibial tubercle osteotomy during TKA. Twenty-three knees in 20 patients (16 women; four men) at a mean age of 54 years with end-stage arthritis and knee stiffness due to RA were operated upon for TKA using tibial tubercle osteotomy as a step during the operation. Patients were reviewed clinically and radiographically with a minimum follow-up of two years. Complications were noted. Hospital for Special Surgery (HSS) score was recorded pre-operatively and at six and 12 months postoperatively. Union occurred at the osteotomy site in 21 of 23 cases. One case had deep venous thrombosis (DVT). There was no infection or periprosthetic fracture, and at last follow-up, no patient required revision. HSS score improved from 46 (15-60) pre-operatively to 85 (71-96) post-operatively. Tibial tubercle osteotomy during TKA in patients with RA and stiff knee is technically demanding yet proved to be effective in improving post-operative range of movement and minimising the complication of patellar ligament avulsion.

  17. Low-energy fracture of posterolateral tibial plateau: treatment by a posterolateral prone approach.

    PubMed

    Yu, Guang-Rong; Xia, Jiang; Zhou, Jia-Qian; Yang, Yun-Feng

    2012-05-01

    Most of the posterolateral tibial plateau fractures are caused by low-energy injury. The posterior fracture fragment could not be exposed and reduced well through traditional approaches. The aim of this study was to review the results of surgical treatment of this kind of fracture using posterolateral approach with patient in prone position. The low-energy posterolateral fracture is defined as the main part of articular depression or split fragment limited within the posterior half of the lateral column. Direct reduction and buttress plate fixation through the posterolateral prone approach was applied in all the patients. In our series, 15 of 132 (11.4%) patients with tibial plateau fractures were identified as low-energy posterolateral fractures. The clinical outcomes were available in 14 of the 15 patients through phone interviews and chart reviews. Mean follow-up was 35.1 months (range: 24-48 months). All the patients had anatomic or good reductions (≤ 2 mm step/gap). Average range of motion was 0.7 degrees to 123.2 degrees (5-110 degrees to 0-140 degrees). The complications were limited to one superficial wound infection, two slight flexion contractures, and five implants removal. The average modified hospital for special surgery knee score was 93.4 (range: 86-100). The posterolateral prone approach provides excellent visualization, which can facilitate the reduction and posterior buttress plate fixation for low-energy posterolateral tibial plateau fractures and shows encouraging results. V, therapeutic study.

  18. [Treatment of Schatzker IV tibial plateau fractures with arthroscopy combined with MIPPO technique].

    PubMed

    Li, Jian-Wen; Ye, Feng; Bi, Da-Wei; Zheng, Xiao-Dong; Chen, Jian-Liang

    2018-02-25

    To discusses the clinical effects of arthroscopy combined with minimally invasive percutaneous plate osteosynthesis(MIPPO) technology in treating Schatzker IV tibial plateau fractures. From January 2012 to January 2016, 19 patients with Schatzker type IV tibial plateau fractures were treated with arthroscopy combined with minimally invasive technique including 12 males and 7 females with an average age of 46.5 years old ranging from 19 to 78 years old. Patients were suffering knee pain, swelling, flexion and extension limited, and other symptoms preoperative. Patients were followed up and assessed by Rasmussen knee function score. No infection, traumatic arthritis, and knee joint valgus occurred after operation. Nineteen cases were followed up for 12 to 24 months with an average of 18.6 months. Fracture healing time was 3 to 5 months with an average of 3.8 months. The knee pain and limited mobility improved significantly. The range of autonomic movement of joints was from 90 to 136 degrees. According to Rasmussen functional score criteria, the total score was 27.00±2.49, the result was excellent in 16 cases, good in 2 cases, fair in 1 case. Arthroscopic treatment for Schatzker type IV tibial plateau fractures combined with MIPPO can simultaneously treat internal structural injuries such as meniscus and other knee joints, with less trauma, fewer complications, and faster joint function recovery, but we must strictly grasp surgical indications and avoid expanding injuries. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  19. Relationship between tibial spine size and the occurrence of osteochondritis dissecans: an argument in favour of the impingement theory.

    PubMed

    Cavaignac, Etienne; Perroncel, Geoffroy; Thépaut, Mathias; Vial, Julie; Accadbled, Franck; De Gauzy, Jérôme Sales

    2017-08-01

    Pathophysiology of osteochondritis dissecans (OCD) of the medial femoral condyle remains uncertain. Specifically, the relationship between the size of the anterior tibial spine (ATS) and the presence of OCD has not been explored. The purpose of this study was to evaluate the relationship between ATS size and the occurrence of OCD. Seventy-nine children between 8 and 17 years of age were included in two groups: OCD (n = 37) and control (n = 42). The groups were matched in terms of age, gender, BMI and weight. Two independent observers performed an MRI analysis of the size of the tibial spine and intercondylar notch relative to the size of the respective epiphyses. For this study, the "S ratio" was calculated by dividing the height of the tibial spine by the height of the tibial epiphysis. The "N ratio" was calculated by dividing the height of the notch by the height of the femoral epiphysis. These two ratios for both groups were compared using Student's t test. The mean value of the S ratio in the OCD group was 0.39 ± 0.06; the mean value of the S ratio in the control group was 0.32 ± 0.03 (P = 0.004). The mean value of the N ratio in the OCD group was 0.70 ± 0.08; the mean value of the N ratio in the control group was 0.70 ± 0.07 (n.s.). This study's findings confirm our hypothesis that patients with OCD have a more prominent tibial spine than in patients without OCD. IV.

  20. 2. VIEW SOUTH, INCLINE PLANE CAR, INCLINE PLANE TRACK, UPPER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW SOUTH, INCLINE PLANE CAR, INCLINE PLANE TRACK, UPPER STATION. - Monongahela Incline Plane, Connecting North side of Grandview Avenue at Wyoming Street with West Carson Street near Smithfield Street, Pittsburgh, Allegheny County, PA

  1. Individual risk factors for deep infection and compromised fracture healing after intramedullary nailing of tibial shaft fractures: a single centre experience of 480 patients.

    PubMed

    Metsemakers, W-J; Handojo, K; Reynders, P; Sermon, A; Vanderschot, P; Nijs, S

    2015-04-01

    Despite modern advances in the treatment of tibial shaft fractures, complications including nonunion, malunion, and infection remain relatively frequent. A better understanding of these injuries and its complications could lead to prevention rather than treatment strategies. A retrospective study was performed to identify risk factors for deep infection and compromised fracture healing after intramedullary nailing (IMN) of tibial shaft fractures. Between January 2000 and January 2012, 480 consecutive patients with 486 tibial shaft fractures were enrolled in the study. Statistical analysis was performed to determine predictors of deep infection and compromised fracture healing. Compromised fracture healing was subdivided in delayed union and nonunion. The following independent variables were selected for analysis: age, sex, smoking, obesity, diabetes, American Society of Anaesthesiologists (ASA) classification, polytrauma, fracture type, open fractures, Gustilo type, primary external fixation (EF), time to nailing (TTN) and reaming. As primary statistical evaluation we performed a univariate analysis, followed by a multiple logistic regression model. Univariate regression analysis revealed similar risk factors for delayed union and nonunion, including fracture type, open fractures and Gustilo type. Factors affecting the occurrence of deep infection in this model were primary EF, a prolonged TTN, open fractures and Gustilo type. Multiple logistic regression analysis revealed polytrauma as the single risk factor for nonunion. With respect to delayed union, no risk factors could be identified. In the same statistical model, deep infection was correlated with primary EF. The purpose of this study was to evaluate risk factors of poor outcome after IMN of tibial shaft fractures. The univariate regression analysis showed that the nature of complications after tibial shaft nailing could be multifactorial. This was not confirmed in a multiple logistic regression model, which

  2. [Biphasic ceramic wedge and plate fixation with locked adjustable screws for open wedge tibial osteotomy].

    PubMed

    Lavallé, F; Pascal-Mousselard, H; Rouvillain, J L; Ribeyre, D; Delattre, O; Catonné, Y

    2004-10-01

    The aim of this radiological study was to evaluate the use of a biphasic ceramic wedge combined with plate fixation with locked adjustable screws for open wedge tibial osteotomy. Twenty-six consecutive patients (27 knees) underwent surgery between December 1999 and March 2002 to establish a normal lower-limb axis. The series included 6 women and 20 men, mean age 50 years (16 right knees and 11 left knees). Partial weight-bearing with crutches was allowed on day 1. A standard radiological assessment was performed on day 1, 90, and 360 (plain AP and lateral stance films of the knee). A pangonogram was performed before surgery and at day 360. Presence of a lateral metaphyseal space, development of peripheral cortical bridges, and osteointegration of the bone substitute-bone interface were evaluated used to assess bone healing. The medial tibial angle between the line tangent to the tibial plateau and the anatomic axis of the tibia (beta) was evaluated to assess preservation of postoperative correction. The HKA angle was determined. Three patients were lost to follow-up and 23 patients (24 knees) were retained for analysis. At last follow-up, presence of peripheral cortical bridges and complete filling of the lateral metaphyseal space demonstrated bone healing in all patients. Good quality osteointegration was achieved since 21 knees did not present an interface between the bone substitute and native bone (homogeneous transition zone). The beta angle was unchanged for 23 knees. A normal axis was observed in patients (16 knees) postoperatively. Use of a biphasic ceramic wedge in combination with plate fixation with locked adjustable screws is a reliable option for open wedge tibial osteotomy. The bone substitute fills the gap well. Tolerance and integration are optimal. Bone healing is achieved. Plate fixation with protected weight bearing appears to be a solid assembly, maintaining these corrections.

  3. Can tibial plateau fractures be reduced and stabilised through an angiosome-sparing antero-lateral approach?

    PubMed

    Solomon, Lucian B; Boopalan, P R J V C; Chakrabarty, Adhiraj; Callary, Stuart A

    2014-04-01

    Tibial plateau fractures (TPFs) are an independent, non-modifiable risk factor for surgical site infections (SSIs). Current antero-lateral approaches to the knee dissect through the anterior tibial angiosome (ATA), which may contribute to a higher rate of SSIs. The aim of this study was to develop an angiosome-sparing antero-lateral approach to allow reduction and fixation of lateral TPFs and to investigate its feasibility in a consecutive cohort. Twenty cadaveric knees were dissected to define the position of the vessels supplying the ATA from the lateral tibial condyle to the skin perforators. Based on these results, an angiosome-sparing surgical approach to treat lateral TPFs was developed. Fifteen consecutive patients were subsequently treated through this approach. Clinical outcomes included assessment of SSI and Lysholm score. Fracture healing and stability were assessed using the Rasmussen score and radiostereometric analysis (RSA). At the latest follow-up between 1 and 4 years, there was no report of SSI. Nine patients (60%) had good or excellent Lysholm scores. The mean Rasmussen score at final follow-up was 17 (median 18, range 14-18) with 10 patients (66%) graded as excellent. Fracture fragment migration measured using RSA was below 2mm in all cases. This study has demonstrated that an angiosome-sparing antero-lateral approach to the lateral tibial plateau is feasible. Adequate stability of these fracture types was achieved by positioning a buttress plate away from the bone and superficial to the regional fascial layer as an 'internal-external fixator'. The angiosome-sparing approach developed was able to be used in a prospective cohort and the clinical results to date are encouraging. Future clinical studies need to investigate the potential benefits of this surgical approach when compared with the previously described antero-lateral approaches. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  4. Early tension loss in an anterior cruciate ligament graft. A cadaver study of four tibial fixation devices.

    PubMed

    Grover, Dustin M; Howell, Stephen M; Hull, Maury L

    2005-02-01

    The tensile force applied to an anterior cruciate ligament graft determines the maximal anterior translation; however, it is unknown whether the tensile force is transferred to the intra-articular portion of the graft and whether the intra-articular tension and maximal anterior translation are maintained shortly after ligament reconstruction. Ten cadaveric knees were reconstructed with a double-looped tendon graft. The graft was looped through a femoral fixation transducer that measured the resultant force on the proximal end of the graft. A pneumatic cylinder applied a tensile force of 110 N to the graft exiting the tibial tunnel with the knee in full extension. The graft was fixed sequentially with four tibial fixation devices (a spiked metal washer, double staples, a bioabsorbable interference screw, and a WasherLoc). Three cyclic loading treatments designed to conservatively load the graft and its fixation were applied. The combined loss in intra-articular graft tension from friction, insertion of the tibial fixation device, and three cyclic loading treatments was 50% for the spiked washer (p = 0.0004), 100% for the double staples (p < 0.0001), 64% for the interference screw (p = 0.0001), and 56% for the WasherLoc (p < 0.0001). The tension loss caused an increase in the maximal anterior translation from that of the intact knee of 2.0 mm for the spiked washer (p = 0.005), 7.8 mm for the double staples (p < 0.0001), 2.7 mm for the interference screw (p = 0.001), and 2.1 mm for the WasherLoc (p < 0.0001). The tensile force applied to a soft-tissue anterior cruciate ligament graft is not transferred intra-articularly and is not maintained during graft fixation. The loss in tension is caused by friction in the tibial tunnel and wrapping the graft around the shank of the screw of the spiked washer, insertion of the tibial fixation device, and cyclical loading of the knee. The amount of tension loss is sufficient to increase the maximal anterior translation.

  5. Rap system of stress stimulation can promote bone union after lower tibial bone fracture: a clinical research.

    PubMed

    Yao, Jian-fei; Shen, Jia-zuo; Li, Da-kun; Lin, Da-sheng; Li, Lin; Li, Qiang; Qi, Peng; Lian, Ke-jian; Ding, Zhen-qi

    2012-01-01

    Lower tibial bone fracture may easily cause bone delayed union or nonunion because of lacking of dynamic mechanical load. Research Group would design a new instrument as Rap System of Stress Stimulation (RSSS) to provide dynamic mechanical load which would promote lower tibial bone union postoperatively. This clinical research was conducted from January 2008 to December 2010, 92 patients(male 61/female 31, age 16-70 years, mean 36.3 years) who suffered lower tibial bone closed fracture were given intramedullary nail fixation and randomly averagely separated into experimental group and control group(according to the successively order when patients went for the admission procedure). Then researchers analysed the clinical healing time, full weight bearing time, VAS (Visual Analogue Scales) score and callus growth score of Lane-Sandhu in 3,6,12 months postoperatively. The delayed union and nonunion rates were compared at 6 and 12 months separately. All the 92 patients had been followed up (mean 14 months). Clinical bone healing time in experimental group was 88.78±8.80 days but control group was 107.91±9.03 days. Full weight bearing time in experimental group was 94.07±9.81 days but control group was 113.24±13.37 days respectively (P<0.05). The delayed union rate in 6 months was 4.3% in experimental group but 10.9% in control group(P<0.05). The nonunion rate in 12 months was 6.5% in experimental group but 19.6% in control group(P<0.05). In 3, 6, 12 months postoperatively, VAS score and Lane-Sandhu score in experimental group had more significantly difference than them in control group. RSSS can intermittently provide dynamic mechanical load and stimulate callus formation, promote lower tibial bone union, reduce bone delayed union or nonunion rate. It is an adjuvant therapy for promoting bone union after lower tibial bone fracture.

  6. [APPLICATION OF V-Y ADVANCED SENSE-REMAINED POSTERIOR TIBIAL ARTERY PERFORATOR FLAP IN REPAIRING WOUND AROUND ANKLE].

    PubMed

    Tang, Xiujun; Wang, Bo; Wei, Zairong; Wang, Dali; Han, Wenjie; Zhang, Wenduo; Li, Shujun

    2015-12-01

    OBJECTIVE To explore the feasibility and effectiveness of V-Y advanced sense-remained posterior tibial artery perforator flap in repairing wound around the ankle. METHODS Between March 2012 and January 2015, 11 patients with wounds around the ankle were treated by V-Y advanced sense-remained posterior tibial artery perforator flap. There were 6 males and 5 females with a median age of 37 years (range, 21-56 years). The causes were traffic accident injury in 3 cases, thermal injury in 2 cases, burn in 2 cases, iatrogenic wounds in 2 cases, and local contusion in 2 cases. The disease duration ranged from 1 to 3 weeks (mean, 2 weeks). Injury was located at the medial malleolus in 4 cases, at the lateral malleolus in 3 cases, and at the heel in 4 cases. All had exposure of bone, tendon, or plate. The defect area ranged from 4 cmx2 cm to 5 cmx3 cm; the area of the flap ranged from 11 cmx4 cm to 15 cmx6 cm. Necrosis of distal flap occurred in 1 case after operation; re-operation to amputate the posterior tibial artery was given and the wound was repaired by proximal skin graft. Light necrosis of distal end was observed in 2 cases, and wound healed at 3 weeks after dressing. And other flaps successfully survived, and primary healing of wounds were obtained. The patients were followed up 6-24 months (mean, 11 months). The flaps were good in color, texture, and appearance. The ankle joint had normal activity. At last follow-up, 10 cases restored fine sense, and 1 case restored protective feeling with posterior tibial artery advanced flap after amputation. V-Y advanced sense-remained posterior tibial artery perforator flap has the advantages of reliable blood supply, simple operation, good appearance, and sensory recovery. Therefore, it is an ideal method to repair wound around the ankle.

  7. [Revision of Schatzker type Ⅵ tibial plateau fracture failure focus on the recovery of lower limb alignment].

    PubMed

    Cong, R J; Liu, J F; Jiang, Y; Dilixiati, Duolikun; Hou, X D; Zheng, L P

    2018-03-01

    Objective: To explore the influence of the lower extremity abnormal alignment and the joint surface, and to explore the surgical skills. Methods: Twenty-two cases of tibial plateau Schatzker Ⅵ fracture internal fixation failure revision from January 2012 to January 2017 in Department of Orthopedics, Shanghai 10(th) Hospital.One year follow-up after initial surgery to make sure of failure.Three-dimensional CT scan, radiography, infection index, gait analysis, knee joint ROM, femur tibia angle, tibial plateau tibial shaft angle and posterior slope if tibial plateau were observed. The medial approach and bi-planer osteotoma were used.Autogenous iliac bone graft, postoperative fast recovery channel were used.Follow-up point included preoperative and postoperative 7 days, 6 weeks, 3 months, and 6 months.Obvervational index included double lower limbs radiography, knee society score(KSS), complications such as infection, skin necrosis, joint main passive activity, double lower limbs alignment the last follow-up SF-36 scale.Rate was compared by χ(2) test, measurement data using paired sample t test.Correlation was analyzed by Pearson correlation regression testing. Results: Twenty-two patients received follow-up.KSS, more than 21 cases were benign, with good gait.One case was poor, with claudication gait.Not skin necrosis, no deep infection cases, 1 case get blisters 2 days postoperatively, and disappear after 5 days with detumescence and cold therapy.Whether restoring force line affect the KSS significantly(χ(2)=22.000, P =0.000). Knee joint ROM, SF-36 score, KSS and lower limb alignment were improved significantly. In different individual the articular surface and anatomical angle recovered greatly but the posterior slope angle was quite difference which has no correlation with KSS and SF-36 scale( P >0.01). Conclusions: Revision of Schatzker type Ⅵ tibial plateau fracture failure should focus on the recovery of lower limb alignment.moderate overcorrect bone

  8. Functional and Radiological Outcome of Schatzker type V and VI Tibial Plateau Fracture Treatment with Dual Plates with Minimum 3 years follow-up: A Prospective Study

    PubMed Central

    Suri, Harpreet Singh; Gangrade, Kewal

    2016-01-01

    Introduction High energy intra-articular fractures involving the tibial plateau causes various problems related to management like wound dehiscence, severe comminution leading to malalignment and delayed complications like varus collapse, implant failure and arthritis of knee joint. Aim This study was done to determine functional, radiological outcome and the complications of Schatzker V and VI tibial plateau fractures treated with bipillar plating with dual plates with a regular follow-up of atleast 3 years. Materials and Methods Total 34 cases of tibial plateau fracture type V and VI treated with dual plating were studied from January 2011 to December 2013 in KIMS Hospital were followed for minimum of 3 years. The patients were operated through an anterolateral approach for lateral plate and a medial column plate was put through a minimally invasive medial approach or an open posteromedial approach. Results Total 34 patients were evaluated postoperatively thoroughly for functional outcome using The Knee Society Score and radiological outcomes by Modified Rasmussen Assessment criteria which showed 29 patients (85.29%) had excellent and 5 patients (14.71%) had good objective knee society score. 24 patients (70.59%) had excellent, 8 patients (23.53%) had good and 1patient (2.94%) were each of poor and fair functional knee society score. Eleven patients (32.35%) had excellent, 21patients (61.76%) had good and 2 patients (5.88%) had fair radiological outcome. Conclusion We conclude that open reduction and internal fixation of high-energy tibial plateau fractures with dual plates via 2 incisions gives excellent to good functional outcome with minimal soft tissue complications. Thus, a minimally invasive approach should be used which helps in preventing soft tissue problems and helps in early wound healing. Fixation done by bipillar plating is important for early mobilization of knee joint. Early mobilization leads to better range of movements and thereby better

  9. Tibial coverage, meniscus position, size and damage in knees discordant for joint space narrowing – data from the Osteoarthritis Initiative

    PubMed Central

    Bloecker, K.; Guermazi, A.; Wirth, W.; Benichou, O.; Kwoh, C.K.; Hunter, D.J.; Englund, M.; Resch, H.; Eckstein, F.

    2013-01-01

    SUMMARY Introduction Meniscal extrusion is thought to be associated with less meniscus coverage of the tibial surface, but the association of radiographic disease stage with quantitative measures of tibial plateau coverage is unknown. We therefore compared quantitative and semi-quantitative measures of meniscus position and morphology in individuals with bilateral painful knees discordant on medial joint space narrowing (mJSN). Methods A sample of 60 participants from the first half (2,678 cases) of the Osteoarthritis Initiative cohort fulfilled the inclusion criteria: bilateral frequent pain, Osteoarthritis Research Society International (OARSI) mJSN grades 1–3 in one, no-JSN in the contra-lateral (CL), and no lateral JSN in either knee (43 unilateral mJSN1; 17 mJSN2/3; 22 men, 38 women, body mass index (BMI) 31.3 ± 3.9 kg/m2). Segmentation and three-dimensional quantitative analysis of the tibial plateau and meniscus, and semi-quantitative evaluation of meniscus damage (magnetic resonance imaging (MRI) osteoarthritis knee score – MOAKS) was performed using coronal 3T MR images (MPR DESSwe and intermediate-weighted turbo spin echo (IW-TSE) images). CL knees were compared using paired t-tests (between-knee, within-person design). Results Medial tibial plateau coverage was 36 ± 9% in mJSN1 vs 45 ± 8% in CL no-JSN knees, and was 31 ± 9% in mJSN2/3 vs 46 ± 6% in no-JSN knees (both P < 0.001). mJSN knees showed greater meniscus extrusion and damage (MOAKS), but no significant difference in meniscus volume. No significant differences in lateral tibial coverage, lateral meniscus morphology or position were observed. Conclusions Knees with medial JSN showed substantially less medial tibial plateau coverage by the meniscus. We suggest that the less meniscal coverage, i.e., less mechanical protection may be a reason for greater rates of cartilage loss observed in JSN knees. PMID:23220556

  10. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    PubMed

    Mui, Leonora W; Engelsohn, Eliyahu; Umans, Hilary

    2007-02-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury.

  11. Spontaneous patella fracture associated with anterior tibial tubercle pseudarthrosis in a revised knee replacement following knee Arthrodesis

    PubMed Central

    2013-01-01

    Background Conversion of a knee arthrodesis to a Total Knee Arthroplasty is an uncommon procedure. Revision Total Knee Arthroplasty in this setting presents the surgeon with a number of challenges including the management of the extensor mechanism and patella. Case presentation We describe a unique case of a 69 years old Caucasian man who underwent a revision Total Knee Arthroplasty using a tibial tubercle osteotomy after a previous conversion of a knee arthrodesis without patella resurfacing. Unfortunately 9 months following surgery a tibial tubercle pseudarthrosis and spontaneous patella fracture occurred. Both were managed with open reduction and internal fixation. At 30 months follow-up the tibial tubercle osteotomy had completely consolidated while the patella fracture was still evident but with no signs of further displacement. The patient was completely satisfied with the outcome and had a painless range of knee flexion between 0-95°. Conclusions We believe that patients undergoing this type of surgery require careful counseling regarding the risk of complications both during and after surgery despite strong evidence supporting improved functional outcomes. PMID:24195600

  12. Atherectomy offers no benefits over balloon angioplasty in tibial interventions for critical limb ischemia.

    PubMed

    Todd, Kevin E; Ahanchi, Sadaf S; Maurer, Christian A; Kim, Jung H; Chipman, Candice R; Panneton, Jean M

    2013-10-01

    Endovascular adjuncts, like atherectomy, were developed to improve outcomes of endovascular arterial interventions. The true impact of atherectomy on endovascular outcomes remains to be determined, and little data exist on the influence of atherectomy on tibial interventions. Our study compares early and late outcomes of tibial intervention with angioplasty vs atherectomy-assisted interventions. We completed a retrospective review of all tibial interventions between 2008 and 2010. Outcomes were analyzed using single and multivariate analysis, Cox regression, and Kaplan-Meier curves. Primary outcomes were primary, primary assisted, and secondary patency rates, as well as limb salvage and survival rates. Over a 2-year period, 480 tibial interventions were completed for 421 patients. Eighty-seven percent (n = 418) of interventions were performed for critical limb ischemia (CLI) and 13% (n = 62) for claudication. The CLI cohort of 418 interventions was analyzed. These patients had a mean age of 71 years with a mean follow-up time of 16 ± 15 months (range, 0-59 months). Of the 418 interventions, 339 underwent percutaneous transluminal angioplasty (PTA): 333 PTA alone, six PTA + stent. The remaining 79 interventions received atherectomy: 33 laser, 13 directional, and 33 orbital either alone or in conjunction with PTA (11 atherectomy only, 68 atherectomy + PTA). The groups did not differ significantly in terms of demographics, risk factors, or technical success. The atherectomy group had more TASC B lesions (54% vs 38%; P = .013), while the PTA-alone group had more TASC D lesions (25% vs 13%; P = .004). TASC A and C lesions did not differ significantly between the groups. No significant differences existed with respect to the early (30-day) outcomes of loss of patency (11% vs 13%; P = .699), complications (8% vs 13%; P = .292), or major amputation (17% vs 13%; P = .344) in the PTA-alone group vs the atherectomy-assisted group. Kaplan-Meier analysis revealed no difference

  13. Delayed Anterior Cruciate Ligament Reconstruction in Young Patients With Previous Anterior Tibial Spine Fractures.

    PubMed

    Mitchell, Justin J; Mayo, Meredith H; Axibal, Derek P; Kasch, Anthony R; Fader, Ryan R; Chadayammuri, Vivek; Terhune, E Bailey; Georgopoulos, Gaia; Rhodes, Jason T; Vidal, Armando F

    2016-08-01

    Avulsion fractures of the anterior tibial spine in young athletes are injuries similar to anterior cruciate ligament (ACL) injuries in adults. Sparse data exist on the association between anterior tibial spine fractures (ATSFs) and later ligamentous laxity or injuries leading to ACL reconstruction. To better delineate the incidence of delayed instability or ACL ruptures requiring delayed ACL reconstruction in young patients with prior fractures of the tibial eminence. Case series; Level of evidence, 4. We identified 101 patients between January 1993 and January 2012 who sustained an ATSF and who met inclusion criteria for this study. All patients had been followed for at least 2 years after the initial injury and were included for analysis after completion of a questionnaire via direct contact, mail, and/or telephone. If patients underwent further surgical intervention and/or underwent later ACL reconstruction, clinical records and operative reports pertaining to these secondary interventions were obtained and reviewed. Differences between categorical variables were assessed using the Fisher exact test. The association between time to revision ACL surgery and fracture type was assessed by Kaplan-Meier plots. The association between need for revision ACL surgery and age, sex, and mechanism of surgery was assessed using logistic regression. Nineteen percent of all patients evaluated underwent delayed ACL reconstruction after a previous tibial spine fracture on the ipsilateral side. While there were a higher proportion of ACL reconstructions in type II fractures, there was not a statistically significant difference in the number of patients within each fracture group who went on to undergo later surgery (P = .29). Further, there was not a significant association between fracture type, sex, or mechanism of injury as it related to the progression to later ACL reconstruction. However, there was a significant association between age at the time of injury and progression

  14. Engineering in-plane silicon nanowire springs for highly stretchable electronics

    NASA Astrophysics Data System (ADS)

    Xue, Zhaoguo; Dong, Taige; Zhu, Zhimin; Zhao, Yaolong; Sun, Ying; Yu, Linwei

    2018-01-01

    Crystalline silicon (c-Si) is unambiguously the most important semiconductor that underpins the development of modern microelectronics and optoelectronics, though the rigid and brittle nature of bulk c-Si makes it difficult to implement directly for stretchable applications. Fortunately, the one-dimensional (1D) geometry, or the line-shape, of Si nanowire (SiNW) can be engineered into elastic springs, which indicates an exciting opportunity to fabricate highly stretchable 1D c-Si channels. The implementation of such line-shape-engineering strategy demands both a tiny diameter of the SiNWs, in order to accommodate the strains under large stretching, and a precise growth location, orientation and path control to facilitate device integration. In this review, we will first introduce the recent progresses of an in-plane self-assembly growth of SiNW springs, via a new in-plane solid-liquid-solid (IPSLS) mechanism, where mono-like but elastic SiNW springs are produced by surface-running metal droplets that absorb amorphous Si thin film as precursor. Then, the critical growth control and engineering parameters, the mechanical properties of the SiNW springs and the prospects of developing c-Si based stretchable electronics, will be addressed. This efficient line-shape-engineering strategy of SiNW springs, accomplished via a low temperature batch-manufacturing, holds a strong promise to extend the legend of modern Si technology into the emerging stretchable electronic applications, where the high carrier mobility, excellent stability and established doping and passivation controls of c-Si can be well inherited. Project supported by the National Basic Research 973 Program (No. 2014CB921101), the National Natural Science Foundation of China (No. 61674075), the National Key Research and Development Program of China (No. 2017YFA0205003), the Jiangsu Excellent Young Scholar Program (No. BK20160020), the Scientific and Technological Support Program in Jiangsu Province (No. BE

  15. Allografts with autogenous platelet-rich plasma for tibial defect reconstruction: a rabbit study.

    PubMed

    Nather, Aziz; Wong, Keng Lin; David, Vikram; Pereira, Barry P

    2012-12-01

    To evaluate the effect of autogenous platelet-rich plasma (PRP) for fresh-frozen allografts in tibial defect reconstruction in rabbits. 40 adult New Zealand white rabbits underwent tibial defect reconstruction with autografts (n=12), allografts without PRP (n=12), or allografts with PRP (n=12) and were observed for 12, 16, and 24 weeks (4 for each period). Tibias of the remaining 4 rabbits were used as donor allografts, and the remaining allografts were procured from recipient rabbits. A 1.5- cm cortical segment of the tibia was osteotomised, and then fixed with a 9-hole mini-compression plate and 2 cerclage wires. Allografts were stripped off the periosteum and soft tissues and medullary contents, and then stored in a freezer at -80 ºC. All allografts were deep frozen for at least 4 weeks before transplantation. 7 ml of whole blood was drawn to prepare 1 ml of PRP. The PRP was then mixed with 1.0 ml of human thrombin to form a platelet gel. The PRP gel was then packed into the medullary canal of the allograft and applied on the cortical surface before tibial defect reconstruction. Rabbits were sacrificed at 12, 16, and 24 weeks. The specimens were assessed for bone union at host-graft junctions and for bone resorption, new bone formation, callus encasement, and viable osteocyte counts. There were 4 specimens in each group at each observation period. Osteoid bridging the gap at host-graft junctions was noted in all specimens in the autograft and allograft-with-PRP groups at week 12 and in the allograft-without-PRP group at week 24. Bone union in allografts without PRP was delayed. All indices for biological incorporation (resorption index, new bone formation index, callus encasement index, and viable osteocyte count) were significantly greater in the autograft than allograft-without-PRP groups, except for the resorption index at week 24, whereas the differences were not significant between the autograft and allograft-with-PRP groups. The differences between the 2

  16. Sports activity after surgical treatment of intra-articular tibial plateau fractures in skiers.

    PubMed

    Loibl, Markus; Bäumlein, Martin; Massen, Felix; Gueorguiev, Boyko; Glaab, Richard; Perren, Thomas; Rillmann, Paavo; Ryf, Christian; Naal, Florian D

    2013-06-01

    Tibial plateau fractures occur frequently while participating in winter sports, but there is no information on whether skiers can resume sports and recreational activities after internal fixation of these fractures. Skiers can resume low-impact sports activity after internal fixation of tibial plateau fractures. Case series; Level of evidence, 4. A total of 103 patients were surveyed by postal questionnaires to determine their sports activities at a mean of 7.8 ± 1.8 years after internal fixation of intra-articular tibial plateau fractures. The survey also included the Lysholm score, the Tegner activity scale, and a visual analog scale (VAS) for pain. At the time of the survey, 88% of the patients were engaged in sports activities (rate of return to sports, 88%), and 53% continued to participate in downhill skiing. The median number of different activities declined from 5 (range, 1-17) preoperatively to 4 (range, 0-11) postoperatively (P < .01). Sports frequency and duration per week did not change: 3 (range, 1-7) preoperatively versus 3 (range, 0-7) postoperatively (P = .275) and 4 hours (range, 1-16 hours) preoperatively versus 3.5 hours (range, 0-15 hours) postoperatively (P = .217), respectively. Median values of all outcome scores declined: Lysholm score, 100 (range, 85-100) preoperatively versus 94.5 (range, 37-100) postoperatively (P < .01); VAS, 0 (range, 0-7) preoperatively versus 1 (range, 0-8) postoperatively (P < .01). Median Tegner activity scale scores declined in all age groups except for patients aged 51 to 60 years. The ability to participate in sports at the time of follow-up compared with the ability before the accident was rated as "similar" by 57 patients (62.0%) and as "worse" by 35 patients (38.0%). The more severe fracture types, B3 and C3 according to the AO classification system, were associated with poorer outcomes related to return to sports and functional scores. A large percentage of skiers with surgically treated intra

  17. Asymmetry in gait pattern following tibial shaft fractures - a prospective one-year follow-up study of 49 patients.

    PubMed

    Larsen, Peter; Laessoe, Uffe; Rasmussen, Sten; Graven-Nielsen, Thomas; Berre Eriksen, Christian; Elsoe, Rasmus

    2017-01-01

    Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12 months post-operatively following intramedullary nailing of a tibial shaft fracture are different compared with a healthy reference population. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns at 6 and 12 months post-operatively measured with a 6-metre-long pressure-sensitive mat. The mat registers footprints and present gait speed, cadence as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. 49 patients were included with a mean age of 43.1 years (18-79 years). Forty-three patients completed the 12-month follow-up (88%). Gait speed and cadence were significantly increased between the 6- and 12-month follow-up (P<0.001). At 6-month follow-up, patients showed considerable asymmetry in the injured leg compared with the non-injured leg: single-support time 12.8% shorter, swing-time 12.8% longer, step-length 11.9% shorter, and rotation of the foot increased by 32.3%. At the 12-month follow-up, gait asymmetry become almost normalized compared to a healthy reference group. In patients treated by intramedullary nailing following a tibial shaft fracture, gait asymmetry accompanied with slower speed and cadence are common during the first 6 months and become normalized compared with a healthy reference population between 6 and 12 months post-operatively. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. In-plane and out-of-plane defectivity in thin films of lamellar block copolymers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahadevapuram, Nikhila; Mitra, Indranil; Bozhchenko, Alona

    2015-10-29

    We investigate the ordering of poly(styrene-b-methyl methacrylate) (PS-PMMA) lamellar copolymers (periodicity L 0 = 46 nm) confined between a free surface and brushed poly(styrene-r-methyl methacrylate) silicon substrate. The processing temperature was selected to eliminate wetting layers at the top and bottom interfaces, producing approximately neutral boundaries that stabilize perpendicular domain orientations. The PS-PMMA film thickness (t = 0.5L 0–2.5L 0) and brush grafting density (Σ = 0.2–0.6 nm –2) were systematically varied to examine their impacts on in-plane and out-of-plane ordering. Samples were characterized with a combination of high-resolution microscopy, X-ray reflectivity, and grazing-incidence small-angle X-ray scattering. In-plane order atmore » the top of the film (quantified through calculation of orientational correlation lengths) improved with t n, where the exponent n increased from 0.75 to 1 as Σ decreased from 0.6 to 0.2 nm –2. Out-of-plane defects such as tilted domains were detected in all films, and the distribution of domain tilt angles was nearly independent of t and Σ. These studies demonstrate that defectivity in perpendicular lamellar phases is three-dimensional, comprised of in-plane topological defects and out-of-plane domain tilt, with little or no correlation between these two types of disorder. As a result, strong interactions between the block copolymer and underlying substrate may trap both kinds of thermally generated defects.« less

  19. Outcome of limb reconstruction system in open tibial diaphyseal fractures.

    PubMed

    Ajmera, Anand; Verma, Ankit; Agrawal, Mukul; Jain, Saurabh; Mukherjee, Arunangshu

    2015-01-01

    Management of open tibial diaphyseal fractures with bone loss is a matter of debate. The treatment options range from external fixators, nailing, ring fixators or grafting with or without plastic reconstruction. All the procedures have their own set of complications, like acute docking problems, shortening, difficulty in soft tissue management, chronic infection, increased morbidity, multiple surgeries, longer hospital stay, mal union, nonunion and higher patient dissatisfaction. We evaluated the outcome of the limb reconstruction system (LRS) in the treatment of open fractures of tibial diaphysis with bone loss as a definative mode of treatment to achieve union, as well as limb lengthening, simultaneously. Thirty open fractures of tibial diaphysis with bone loss of at least 4 cm or more with a mean age 32.5 years were treated by using the LRS after debridement. Distraction osteogenesis at rate of 1 mm/day was done away from the fracture site to maintain the limb length. On the approximation of fracture ends, the dynamized LRS was left for further 15-20 weeks and patient was mobilized with weight bearing to achieve union. Functional assessment was done by Association for the Study and Application of the Methods of Illizarov (ASAMI) criteria. Mean followup period was 15 months. The mean bone loss was 5.5 cm (range 4-9 cm). The mean duration of bone transport was 13 weeks (range 8-30 weeks) with a mean time for LRS in place was 44 weeks (range 24-51 weeks). The mean implant index was 56.4 days/cm. Mean union time was 52 weeks (range 31-60 weeks) with mean union index of 74.5 days/cm. Bony results as per the ASAMI scoring were excellent in 76% (19/25), good in 12% (3/25) and fair in 4% (1/25) with union in all except 2 patients, which showed poor results (8%) with only 2 patients having leg length discrepancy more than 2.5 cm. Functional results were excellent in 84% (21/25), good in 8% (2/25), fair in 8% (2/25). Pin tract infection was seen in 5 cases, out of which 4

  20. Changes in tibial bone microarchitecture in female recruits in response to 8 weeks of U.S. Army Basic Combat Training.

    PubMed

    Hughes, Julie M; Gaffney-Stomberg, Erin; Guerriere, Katelyn I; Taylor, Kathryn M; Popp, Kristin L; Xu, Chun; Unnikrishnan, Ginu; Staab, Jeffery S; Matheny, Ronald W; McClung, James P; Reifman, Jaques; Bouxsein, Mary L

    2018-08-01

    U.S. Army Basic Combat Training (BCT) is a physically-demanding program at the start of military service. Whereas animal studies have shown that increased mechanical loading rapidly alters bone structure, there is limited evidence of changes in bone density and structure in humans exposed to a brief period of unaccustomed physical activity. We aimed to characterize changes in tibial bone density and microarchitecture and serum-based biochemical markers of bone metabolism in female recruits as a result of 8 weeks of BCT. We collected high-resolution peripheral quantitative computed tomographic images of the distal tibial metaphysis and diaphysis (4% and 30% of tibia length from the distal growth plate, respectively) and serum markers of bone metabolism before and after BCT. Linear mixed models were used to estimate the mean difference for each outcome from pre- to post-BCT, while controlling for race/ethnicity, age, and body mass index. 91 female BCT recruits volunteered and completed this observational study (age = 21.5 ± 3.3 yrs). At the distal tibial metaphysis, cortical thickness, trabecular thickness, trabecular number, bone volume/total volume, and total and trabecular volumetric bone density (vBMD) increased significantly by 1-2% (all p < 0.05) over the BCT period, whereas trabecular separation, cortical tissue mineral density (TMD), and cortical vBMD decreased significantly by 0.3-1.0% (all p < 0.05). At the tibial diaphysis, cortical vBMD and cortical TMD decreased significantly (both -0.7%, p < 0.001). Bone strength, estimated by micro finite element analysis, increased by 2.5% and 0.7% at the distal tibial metaphysis and diaphysis, respectively (both p < 0.05). Among the biochemical markers of bone metabolism, sclerostin decreased (-5.7%), whereas bone alkaline phosphatase, C-telopeptide cross-links of type 1 collagen, tartrate-resistance acid phosphatase, and 25(OH)D increased by 10-28% (all p < 0.05). BCT leads to