Science.gov

Sample records for plates alternative method

  1. Extraction of gadolinium from high flux isotope reactor control plates. [Alternative method

    SciTech Connect

    Kohring, M.W.

    1987-04-01

    Gadolinium-153 is an important radioisotope used in the diagnosis of various bone disorders. Recent medical and technical developments in the detection and cure of osteoporosis, a bone disease affecting an estimated 50 million people, have greatly increased the demand for this isotope. The Oak Ridge National Laboratory (ORNL) has produced /sup 153/Gd since 1980 primarily through the irradiation of a natural europium-oxide powder followed by the chemical separation of the gadolinium fraction from the europium material. Due to the higher demand for /sup 153/Gd, an alternative production method to supplement this process has been investigated. This process involves the extraction of gadolinium from the europium-bearing region of highly radioactive, spent control plates used at the High Flux Isotope Reactor (HFIR) with a subsequent re-irradiation of the extracted material for the production of the /sup 153/Gd. Based on the results of experimental and calculational analyses, up to 25 grams of valuable gadolinium (greater than or equal to60% enriched in /sup 152/Gd) resides in the europium-bearing region of the HFIR control components of which 70% is recoverable. At a specific activity yield of 40 curies of /sup 153/Gd for each gram of gadolinium re-irradiated, 700 one-curie sources can be produced from each control plate assayed.

  2. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  3. Alternative to Ph. Eur. pour-plate method for detection of microbial contamination in non-sterile pharmaceutical preparations.

    PubMed

    Palicz, A; Paul, A; Hofmann, A; Denzel, K

    2016-01-01

    The current European Pharmacopoeia (Ph. Eur.) texts for Interferon (IFN)-alfa-2 include a nonspecific photometric protein assay using albumin as calibrator and a highly variable cell-based assay for the potency determination of the protective effects. A request was expressed by the Official Medicines Control Laboratories (OMCLs) for improved methods for the batch control of recombinant interferon alfa-2 bulk and market surveillance testing of finished products, including those formulated with Human Serum Albumin (HSA). A HPLC method was developed at the Medical Products Agency (MPA, Sweden) for the testing of IFN-alfa-2 products. An initial collaborative study run under the Biological Standardisation Programme (BSP; study code BSP039) revealed the need for minor changes to improve linearity of the calibration curves, assay reproducibility and robustness. The goal of the collaborative study, coded BSP071, was to transfer and further validate this improved HPLC method. Ten laboratories participated in the study. Four marketed IFN-alfa-2 preparations (one containing HSA) together with the Ph. Eur. Chemical Reference Substance (CRS) for IFN-alfa-2a and IFN-alfa-2b, and in-house reference standards from two manufacturers were used for the quantitative assay. The modified method was successfully transferred to all laboratories despite local variation in equipment. The resolution between the main and the oxidised forms of IFN-alfa-2 was improved compared to the results from the BSP039 study. The improved method even allowed partial resolution of an extra peak after the principal peak. Symmetry of the main IFN peak was acceptable for all samples in all laboratories. Calibration curves established with the Ph. Eur. IFN-alfa-2a and IFN-alfa-2b CRSs showed excellent linearity with intercepts close to the origin and coefficients of determination greater than 0.9995. Assay repeatability, intermediate precision and reproducibility varied with the tested sample within acceptable

  4. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  5. Balser plate stabilization: an alternate therapy for traumatic sternoclavicular instability.

    PubMed

    Franck, Wolfgang M; Jannasch, Olof; Siassi, Michael; Hennig, Friedrich F

    2003-01-01

    Traumatic instability of the sternoclavicular joint is a rare condition. It can be treated by surgical cerclage fixation, which necessitates postoperative immobilization, an approach preventing early postoperative functional rehabilitation. Balser plate stabilization is a therapeutic alternative that does not require extended periods of immobilization. From January 1, 1996, to December 31, 2000, a total of 10 trauma patients with unstable sternoclavicular joints (Allman grade III) requiring surgical management were treated with Balser plate stabilization to allow early physiotherapy. The population included 7 patients with anterior dislocations, 2 with posterior dislocations, and 1 with medial epiphysiolysis in addition to posterior dislocation. Implants were removed from 9 patients after 3 months and 1 patient after 2 months. One year or longer after the procedure, 9 of 10 patients were available for follow-up; 1 patient had moved. The results achieved with this alternative treatment are excellent. There were no cases of redislocation. The only surgical complication was a seroma that required surgical drainage. One patient had arthrosis develop. Outcome was assessed with Constant (range, 84-100; mean, 90.2 +/- 6.6) and DASH (disabilities of the arm, shoulder, and hand) (range, 4.1-16.6; mean, 8.4 +/- 1.4) scores. For the rare case of sternoclavicular joint dislocation requiring open surgical reduction and stabilization, the Balser plate technique is reliable, permits early movement, has good postoperative results, and compares favorably with alternative methods. PMID:12851582

  6. Aluminum transfer method for plating plastics

    NASA Technical Reports Server (NTRS)

    Goodrich, W. D.; Stalmach, C. J., Jr.

    1977-01-01

    Electroless plating technique produces plate of uniform thickness. Hardness and abrasion resistance can be increased further by heat treatment. Method results in seamless coating over many materials, has low thermal conductivity, and is relatively inexpensive compared to conventional methods.

  7. Consecutive plate acoustic suppressor apparatus and methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony (Inventor)

    1992-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  8. Consecutive Plate Acoustic Suppressor Apparatus and Methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony L. (Inventor)

    1993-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  9. HVOF thermal spraying: An alternative to hard chrome plating

    SciTech Connect

    Bolles, D.C.

    1995-10-01

    In recent years pressure to find alternatives to chromium electroplating has accelerated dramatically. While it is not likely that the process will be banned completely, the trend points to severe limitations. Industries must now look closely at their applications, and actively consider alternatives to hard chrome plaint. One of the most viable alternatives in thermal spraying. Recent advances in high-velocity oxygen fuel (HVOF) technology offer an environmentally safer, cleaner and less-expensive alternative to chromium plating. It has been shown here that HVOF coatings can be used as chromium plating alternatives for many different applications. The HVOF process offers several advantages over chromium plaint including thicker coating capability, no part size restrictions and no hazardous waste products. A number of HVOF coatings have had excellent results in laboratory and field testing, and can be considered as effective replacements for hard chrome. The choice for a suitable replacement can only be made after careful assessment of the conditions associated with the application in question.

  10. Spiral Plate Method for Bacterial Determination

    PubMed Central

    Gilchrist, J. E.; Campbell, J. E.; Donnelly, C. B.; Peeler, J. T.; Delaney, J. M.

    1973-01-01

    A method is described for determining the number of bacteria in a solution by the use of a machine which deposits a known volume of sample on a rotating agar plate in an ever decreasing amount in the form of an Archimedes spiral. After the sample is incubated, different colony densities are apparent on the surface of the plate. A modified counting grid is described which relates area of the plate of volume of sample. By counting an appropriate area of the plate, the number of bacteria in the sample is estimated. This method was compared to the pour plate procedure with the use of pure and mixed cultures in water and milk. The results did not demonstrate a significant difference in variance between duplicates at the α = 0.01 level when concentrations of 600 to 12 × 105 bacteria per ml were used, but the spiral plate method gave counts that were higher than counts obtained by the pour plate method. The time and materials required for this method are substantially less than those required for the conventional aerobic pour plate procedure. Images PMID:4632851

  11. Method for plating with metal oxides

    DOEpatents

    Silver, G.L.; Martin, F.S.

    1994-08-23

    A method is disclosed of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate. 1 fig.

  12. Method for plating with metal oxides

    DOEpatents

    Silver, Gary L.; Martin, Frank S.

    1994-08-23

    A method of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate.

  13. Effusion plate using additive manufacturing methods

    DOEpatents

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  14. [Alternative treatment methods in ENT].

    PubMed

    Friese, K H

    1997-08-01

    In this review, the most important complementary und alternative therapies are discussed, focusing particularly on their use in otorhinolaryngology. These therapies include balneology, Kneipp therapy, microbiological therapy, fasting, excretion therapy, different oxygen therapies, hydro-colon therapy, urine therapy, own-blood therapy, Bach therapy, orthomolecular therapy, order therapy, environmental medicine, phytotherapy, homeopathy, complex homeopathy, anthroposophy, neural therapy, electroaccupuncture according to Voll and similar therapies, nasal reflex therapy, reflex-zone massage, manual therapy, massage, lymph drainage, aroma therapy, thermotherapy, bioresonance, kinesiology, hopi candles, and dietetics. Some of these methods and regimens can be recommended, but others should be rejected. In universities, these methods are only represented to a minor extend, but are more accepted by otorhinolaryngologists in practice. This paper provides a guide to which alternative therapies are sensible and possible in otorhinolaryngology. The aim is to stimulate interest in these methods. It is necessary to discuss these alternative methods reasonably and credibly with patients. PMID:9378666

  15. An Alternative Estimate of the Motion of the Capricorn Plate

    NASA Astrophysics Data System (ADS)

    Burris, S. G.; Gordon, R. G.

    2013-12-01

    Diffuse plate boundaries cover ~15% of Earth's surface and can exceed 1000 km in across-strike width. Deforming oceanic lithosphere in the equatorial Indian Ocean accommodates the motion between the India and Capricorn plates and serves as their mutual diffuse plate boundary. This deforming lithosphere lies between the Central Indian Ridge to the west and the Sumatra trench to the east; the plates diverge to the west of ≈74°E and converge to the east of it. Many data have shown that the pole of rotation between the India and Capricorn plates lies within this diffuse plate boundary [1,2]. Surprisingly, however, the recently estimated angular velocity in the MORVEL global set of angular velocities [3] places this pole of rotation north of prior poles by several degrees, and north of the diffuse plate boundary. The motion between the India and Capricorn plates can only be estimated indirectly by differencing the motion of the India plate relative to the Somalia plate, on the one hand, and the motion of the Capricorn plate relative to Somalia plate, on the other. While the MORVEL India-Somalia angular velocity is similar to prior estimates, the MORVEL Capricorn-Somalia pole of rotation lies northwest of its predecessors. The difference is not caused by new transform azimuth data incorporated into MORVEL or by the new application of a correction to spreading rates for outward displacement. Instead the difference appears to be caused by a few anomalous spreading rates near the northern end of the Capricorn-Somalia plate boundary along the Central Indian Ridge. Rejecting these data leads to consistency with prior results. Implications for the motion of the Capricorn plate relative to Australia will be discussed. [1] DeMets, C., R. G. Gordon, and J.-Y. Royer, 2005. Motion between the Indian, Capricorn, and Somalian plates since 20 Ma: implications for the timing and magnitude of distributed deformation in the equatorial Indian ocean, Geophys. J. Int., 161, 445-468. [2

  16. Anterior plating as a surgical alternative in the treatment of humeral shaft non-union.

    PubMed

    Livani, Bruno; Belangero, William; Medina, Giovanna; Pimenta, Ciro; Zogaib, Rodrigo; Mongon, Mauricio

    2010-10-01

    This study included 15 patients with humeral shaft fractures who had no clinical, radiological or bone scan signs of healing after eight months. The patients were followed for a mean of 35.8 months. No patient was lost to follow-up. Anterior plating of humeral shaft nonunion via an anterior approach was performed using a straight plate and compression for well-vascularised non-unions and wave plating with a tricortical graft for poorly vascularised non-unions. All non-unions healed within 6-18 weeks (mean, nine weeks) without local complication. One patient had a mild decrease in elbow and shoulder range of motion. No neurovascular injury was observed. Anterior plating is a simple, safe and effective treatment for humeral shaft non-union. As this approach avoids the need for radial nerve visualisation and extensive soft-tissue dissection, and the healing time is similar to that of other methods, we suggest this treatment as an alternative option. PMID:19730860

  17. Anterior plating as a surgical alternative in the treatment of humeral shaft non-union

    PubMed Central

    Belangero, William; Medina, Giovanna; Pimenta, Ciro; Zogaib, Rodrigo; Mongon, Mauricio

    2009-01-01

    This study included 15 patients with humeral shaft fractures who had no clinical, radiological or bone scan signs of healing after eight months. The patients were followed for a mean of 35.8 months. No patient was lost to follow-up. Anterior plating of humeral shaft nonunion via an anterior approach was performed using a straight plate and compression for well-vascularised non-unions and wave plating with a tricortical graft for poorly vascularised non-unions. All non-unions healed within 6–18 weeks (mean, nine weeks) without local complication. One patient had a mild decrease in elbow and shoulder range of motion. No neurovascular injury was observed. Anterior plating is a simple, safe and effective treatment for humeral shaft non-union. As this approach avoids the need for radial nerve visualisation and extensive soft-tissue dissection, and the healing time is similar to that of other methods, we suggest this treatment as an alternative option. PMID:19730860

  18. Microporous microchannel plates and method of manufacturing same

    DOEpatents

    Beetz, Jr., Charles P.; Boerstler, Robert W.; Steinbeck, John; Winn, David R.

    2000-01-01

    A microchannel plate and method of manufacturing same is provided. The microchannel plate includes a plate consisting of an anodized material and a plurality of channels which are formed during the anodization of the material and extend between the two sides of the plate. Electrodes are also disposed on each side of the plate for generating an electrical field within the channels. Preferably, the material is alumina and the channels are activated such that the channel walls are conductive and highly secondary emissive.

  19. Buccal plate augmentation: a new alternative to socket preservation.

    PubMed

    Caiazzo, Alfonso; Brugnami, Federico; Mehra, Pushkar

    2010-10-01

    Alveolar ridge resorption occurs after tooth extraction and has the potential to either complicate implant placement or impair the final esthetic result. Techniques to preserve natural bone and soft tissue contours are of great interest to clinicians and patients because even subtle postextraction buccal plate resorption may have significant clinical effects, particularly in the esthetic zone. Buccal plate augmentation (BPA) is a novel approach for ridge preservation aiming to avoid recession of the facial wall of the socket without interfering with the natural healing mechanism of the extraction socket. It consists of placement of bone graft material over an intact buccal plate, underneath the soft tissues in a surgically created pouch with an aim to maintain or augment the soft tissue esthetics of the region. PMID:20863942

  20. Apparatus and method for controlling plating uniformity

    DOEpatents

    Hachman Jr., John T.; Kelly, James J.; West, Alan C.

    2004-10-12

    The use of an insulating shield for improving the current distribution in an electrochemical plating bath is disclosed. Numerical analysis is used to evaluate the influence of shield shape and position on plating uniformity. Simulation results are compared to experimental data for nickel deposition from a nickel--sulfamate bath. The shield is shown to improve the average current density at a plating surface.

  1. Complementary and Alternative Methods and Cancer

    MedlinePlus

    ... My Saved Articles » My ACS » Complementary and Alternative Methods and Cancer Download Printable Version [PDF] » ( En español ) ... with cancer here. What are complementary and alternative methods? How are complementary methods used to manage cancer? ...

  2. Method of assembling a plate-fin heat exchanger

    SciTech Connect

    Kopczynski, J.F.

    1986-07-22

    A method is described of assembling a plate-fin heat exchanger comprising the steps of providing like substantially straight elongate plate fins with spaced holes therein, bowing the plate-fins to increase their stability and accumulating the plate fins in a stacked contiguous relationship to provide a bundle, providing elongated substantially parallel tubes spaced from each other substantially the same distance as the spaced holes and oriented substantially perpendicularly to the stacked plate fins, and mounting the plate fins in the stacked contiguous relationship onto the elongated substantially parallel tubes by inserting the substantially parallel tubes into the spaced holes, transferring the bundle of bowed plate-fins into a carriage, and transferring the bundle of plate-fins from the carriage onto the elongated substantially parallel tubes.

  3. A comparison of ultrasonic and X-ray methods for imaging the growth plate.

    PubMed

    Han, S M; Kim, S H

    2005-07-01

    The purpose of this study was to assess a systematic and scientific method for measuring children's growth development, in which the accuracy of the existing diagnostic method has not yet been concretely examined. The most popular method for diagnosis of children's growth is to analyse the opening degree of the growth plate in each joint by an X-ray image. However, the X-ray method has some disadvantages; it is impossible to measure the diagnosis of growth periodically and repeatedly due to the radiation problem. Hence, this study introduced a profile analysis and the algorithm of analysing the image of the growth plate using the broadband ultrasound attenuation (BUA) of calcaneus, to verify the possibility of using an alternative ultrasonic method harmless to the human body. The images of the growth plate in the proximal tibiae, phalanges, and calcanei of 269 children (7-16 years old) were obtained using X-ray. The image of the growth plate in the calcanei was also obtained from these children using ultrasound. The results showed that the time of the opening degree of the growth plate in each joint was almost consistent between X-ray and ultrasonic images. Also, the images of the growth plate measured using X-ray and ultrasound showed a high correlation. Therefore, it is expected that the algorithm of ultrasonic profile analysis introduced in this study can replace the existing X-ray method to measure the growth plate correctly. PMID:16050219

  4. Alternate Methods of Teaching Psychopharmacology

    ERIC Educational Resources Information Center

    Zisook, Sidney; Benjamin, Sheldon; Balon, Richard; Glick, Ira; Louie, Alan; Moutier, Christine; Moyer, Trenton; Santos, Cynthia; Servis, Mark

    2005-01-01

    Objective: This article reviews methods used to teach psychopharmacology to psychiatry residents that utilize principles of adult learning, enlist active participation of residents, and provide faculty with skills to seek, analyze, and use new information over the course of their careers. Methods: The pros and cons of five "nonlecture" methods of…

  5. Conductivity fuel cell collector plate and method of fabrication

    DOEpatents

    Braun, James C.

    2002-01-01

    An improved method of manufacturing a PEM fuel cell collector plate is disclosed. During molding a highly conductive polymer composite is formed having a relatively high polymer concentration along its external surfaces. After molding the polymer rich layer is removed from the land areas by machining, grinding or similar process. This layer removal results in increased overall conductivity of the molded collector plate. The polymer rich surface remains in the collector plate channels, providing increased mechanical strength and other benefits to the channels. The improved method also permits greater mold cavity thickness providing a number of advantages during the molding process.

  6. A method for making an alkaline battery electrode plate

    NASA Technical Reports Server (NTRS)

    Chida, K.; Ezaki, T.

    1983-01-01

    A method is described for making an alkaline battery electrode plate where the desired active substances are filled into a nickel foam substrate. In this substrate an electrolytic oxidation reduction occurs in an alkaline solution containing lithium hydroxide.

  7. Alternative Asbestos Control Method (AACM), Washington

    EPA Science Inventory

    This presentation describes the status to date of the Alternative Asbestos Control Method research, which is intended as a possible alternative technology for use in the demolition of buildings that contain asbestos and are covered under the regulatory requirements of the Asbesto...

  8. An Examination of Alternative Instructional Methods

    ERIC Educational Resources Information Center

    Brewer, Peggy D.

    2004-01-01

    Demographic shifts, advances in technology, and changing student perceptions and expectations have influenced the development of alternative means and methods for offering and delivering traditional college courses. This study reports student perceptions of four alternatives at one university where students were asked to rate course offerings…

  9. Methods for Characterization of Alternative RNA Splicing

    PubMed Central

    Harvey, Samuel E.; Cheng, Chonghui

    2016-01-01

    Quantification of alternative splicing to detect the abundance of differentially spliced isoforms of a gene in total RNA can be accomplished via RT-PCR using both quantitative real-time and semi-quantitative PCR methods. These methods require careful PCR primer design to ensure specific detection of particular splice isoforms. We also describe analysis of alternative splicing using a splicing “minigene” in mammalian cell tissue culture to facilitate investigation of the regulation of alternative splicing of a particular exon of interest. PMID:26721495

  10. A new method of making 164Dy metal plate targets

    NASA Astrophysics Data System (ADS)

    Sugai, Isao; Kato, Hajime

    1986-04-01

    164Dy metal plate targets of high purity for measurements of the electron neutrino mass were made successfully. The starting material 164DyF 3 was reduced to metal by the Ca reduction method with rf induction heating. The reduced metal was pressed with a hot-press device in argon gas atmosphere and rolled into plates of 35 mm × 10 mm in area by a new method of packing. The thicknesses were in the range from 150 to 230 mg/cm 2. The present method was also found suitable to make thin Dy targets of the order of 1 mg/cm 2 in thickness

  11. Method to reduce damage to backing plate

    DOEpatents

    Perry, Michael D.; Banks, Paul S.; Stuart, Brent C.

    2001-01-01

    The present invention is a method for penetrating a workpiece using an ultra-short pulse laser beam without causing damage to subsequent surfaces facing the laser. Several embodiments are shown which place holes in fuel injectors without damaging the back surface of the sack in which the fuel is ejected. In one embodiment, pulses from an ultra short pulse laser remove about 10 nm to 1000 nm of material per pulse. In one embodiment, a plasma source is attached to the fuel injector and initiated by common methods such as microwave energy. In another embodiment of the invention, the sack void is filled with a solid. In one other embodiment, a high viscosity liquid is placed within the sack. In general, high-viscosity liquids preferably used in this invention should have a high damage threshold and have a diffusing property.

  12. OVERVIEW ON ALTERNATIVE ASBESTOS CONTROL METHOD RESEARCH

    EPA Science Inventory

    The alternative asbestos control method (AACM) is an experimental approach to building demolition. Unlike the NESHAP method, the AACM allows some regulated asbestos-containing material to remain in the building and a surfactant-water solution is used to suppress asbestos fibers ...

  13. A modified agar plate method for detection of Strongyloides stercoralis.

    PubMed

    Koga, K; Kasuya, S; Khamboonruang, C; Sukhavat, K; Ieda, M; Takatsuka, N; Kita, K; Ohtomo, H

    1991-10-01

    The agar plate method is a new technique with high detection rates for coprological diagnosis of human strongyloidiasis. This report details modifications of the technique and establishes a standardized procedure. We recommend that all plates should be carefully observed using a microscope because macroscopic observation can lead to false negative results. It is also advisable to pour formalin solution directly into microscopically positive dishes to collect worms by sedimentation. This procedure enables one to observe worms otherwise hidden. Sealing dishes with adhesive tape prevents larvae from crawling out of the dishes, eliminating any possibility in the reduction of detection rates, and greatly improves the safety conditions for the technician performing the procedure. We consider the agar plate method to be superior to the filter paper method in detecting Strongyloides, and we believe that it will eventually become the technique of choice. PMID:1951861

  14. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus

    PubMed Central

    Cold, Emma R.; Freyria, Nastasia J.; Martínez Martínez, Joaquín; Fernández Robledo, José A.

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham’s F12–5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham’s F12–5% FBS– 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham’s F12–5% FBS– 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications. PMID:27149378

  15. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus.

    PubMed

    Cold, Emma R; Freyria, Nastasia J; Martínez Martínez, Joaquín; Fernández Robledo, José A

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham's F12-5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham's F12-5% FBS- 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham's F12-5% FBS- 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications. PMID:27149378

  16. Method for conducting electroless metal-plating processes

    DOEpatents

    Petit, George S.; Wright, Ralph R.

    1978-01-01

    This invention is an improved method for conducting electroless metal-plating processes in a metal tank which is exposed to the plating bath. The invention solves a problem commonly encountered in such processes: how to determine when it is advisable to shutdown the process in order to clean and/or re-passivate the tank. The new method comprises contacting the bath with a current-conducting, non-catalytic probe and, during plating operations, monitoring the gradually changing difference in electropotential between the probe and tank. It has been found that the value of this voltage is indicative of the extent to which nickel-bearing decomposition products accumulate on the tank. By utilizing the voltage to determine when shutdown for cleaning is advisable, the operator can avoid premature shutdown and at the same time avoid prolonging operations to the point that spontaneous decomposition occurs.

  17. Inverse methods-based estimation of plate coupling in a plate motion model governed by mantle flow

    NASA Astrophysics Data System (ADS)

    Ratnaswamy, V.; Stadler, G.; Gurnis, M.

    2013-12-01

    Plate motion is primarily controlled by buoyancy (slab pull) which occurs at convergent plate margins where oceanic plates undergo deformation near the seismogenic zone. Yielding within subducting plates, lateral variations in viscosity, and the strength of seismic coupling between plate margins likely have an important control on plate motion. Here, we wish to infer the inter-plate coupling for different subduction zones, and develop a method for inferring it as a PDE-constrained optimization problem, where the cost functional is the misfit in plate velocities and is constrained by the nonlinear Stokes equation. The inverse models have well resolved slabs, plates, and plate margins in addition to a power law rheology with yielding in the upper mantle. Additionally, a Newton method is used to solve the nonlinear Stokes equation with viscosity bounds. We infer plate boundary strength using an inexact Gauss-Newton method with line search for backtracking. Each inverse model is applied to two simple 2-D scenarios (each with three subduction zones), one with back-arc spreading and one without. For each case we examine the sensitivity of the inversion to the amount of surface velocity used: 1) full surface velocity data and 2) surface velocity data simplified using a single scalar average (2-D equivalent to an Euler pole) for each plate. We can recover plate boundary strength in each case, even in the presence of highly nonlinear flow with extreme variations in viscosity. Additionally, we ascribe an uncertainty in each plate's velocity and perform an uncertainty quantification (UQ) through the Hessian of the misfit in plate velocities. We find that as plate boundaries become strongly coupled, the uncertainty in the inferred plate boundary strength decreases. For very weak, uncoupled subduction zones, the uncertainty of inferred plate margin strength increases since there is little sensitivity between plate margin strength and plate velocity. This result is significant

  18. 76 FR 21673 - Alternative Efficiency Determination Methods and Alternate Rating Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-18

    ...-substantiation of an AEDM or ARM as a result of a change in standard or test procedure. 76 FR 12492 (March 7...; ] DEPARTMENT OF ENERGY 10 CFR Part 431 RIN 1904-AC46 Alternative Efficiency Determination Methods and Alternate Rating Methods AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy....

  19. Alternative Methods of Determining Teacher Salaries.

    ERIC Educational Resources Information Center

    Whitworth, Fred E.; O'Neil, Roy J.

    This publication consists of two papers that examine different topics related to collective bargaining for school personnel and alternative methods of determining teachers' and principals' salaries. The papers were originally prepared to serve as a basis for discussion at a 1976 meeting sponsored by the Canadian School Trustees' Association for…

  20. Alternative Therapies and Methods of Learning

    ERIC Educational Resources Information Center

    Warren, Jennifer

    2008-01-01

    When her daughter was almost two years old, the author realized that she had never crawled. Reluctant to depend on someone else to lead her daughter's therapies and learning, she began to search for alternative developmental therapy approaches and learning methods that would allow her to become more informed and take a more active role. She found…

  1. Self-calibration method of two-dimensional grid plate

    NASA Astrophysics Data System (ADS)

    Ding, Guoqing; Chen, Xin; Wang, Lihua; Lei, Lihua; Li, Yuan

    2011-12-01

    A two-dimensional grid plate can offer an X-Y position standard where grids are aligned orthogonal to each other. It is important to ensure the positional accuracy of the grid plate when the grid plate is used to calibrate planar movement systems, such as vision measuring machines and scanning probe microscopes. Existing algorithms for self-calibration employ the discrete Fourier transform, which is complicated and has poor noise suppression capability. We have developed an algorithm that can achieve exact self-calibration for a two-dimensional grid plate using the least squares method when there is no random noise. In the presence of random noise, the algorithm still presents an excellent capability for noise suppression. As an extension of the classic three-location measurement, the algorithm can be applied to four- or five-location measurements, which reduce measurement uncertainties. The error propagation characteristic of the random errors has been investigated in the case of different measurement strategies. According to the simulation results, the mean error propagation ratios are less than 1 when the array size of the grid plate is less than 32×32. Finally, the influence of the scale errors of the planar movement system is discussed.

  2. Methods of localization of Lamb wave sources on thin plates

    NASA Astrophysics Data System (ADS)

    Turkaya, Semih; Toussaint, Renaud; Kvalheim Eriksen, Fredrik; Daniel, Guillaume; Grude Flekkøy, Eirik; Jørgen Måløy, Knut

    2015-04-01

    Signal localization techniques are ubiquitous in both industry and academic communities. We propose a new localization method on plates which is based on energy amplitude attenuation and inverted source amplitude comparison. This inversion is tested on synthetic data using Lamb wave propagation direct model and on experimental dataset (recorded with 4 Brüel & Kjær Type 4374 miniature piezoelectric shock accelerometers (1-26 kHz frequency range)). We compare the performance of the technique to the classical source localization algorithms, arrival time localization, time reversal localization, localization based on energy amplitude. Furthermore, we measure and compare the accuracy of these techniques as function of sampling rate, dynamic range, geometry, Signal to Noise Ratio, and we show that this very versatile technique works better than classical ones over the sampling rates 100kHz - 1MHz. Experimental phase consists of a glass plate having dimensions of 80cmx40cm with a thickness of 1cm. Generated signals due to a wooden hammer hit or a steel ball hit are captured by sensors placed on the plate on different locations with the mentioned sensors. Numerical simulations are done using dispersive far field approximation of plate waves. Signals are generated using a hertzian loading over the plate. Using imaginary sources outside the plate boundaries the effect of reflections is also included. This proposed method, can be modified to be implemented on 3d environments, monitor industrial activities (e.g boreholes drilling/production activities) or natural brittle systems (e.g earthquakes, volcanoes, avalanches).

  3. Grid base plate for an electrode plate for a storage battery and method of manufacture thereof

    SciTech Connect

    Sano, I.; Suzuki, Y.

    1981-06-02

    A grid base plate and its method of manufacture is described. The method is comprised of intermittently conveying a thin elongated metallic sheet longitudinally in one direction through successive first, second and third stations, the sheet being stopped in each of the stations between successive conveying steps. In the first station , the sheet is bent to form a peripheral upwardly projecting portion in a frame region surrounding an inner grid region. In the second station, a plurality of openings are punched in the grid region and in the third station, the sheet is punched along an outer peripheral edge surface to separate the base plate from the sheet. The upwardly projecting portion forms a space with the grid region which is filled with an active material of a thickness determined by the height of the upwardly projecting portion. The upwardly projecting portion has an outer bend region with an end surface constituting a peripheral edge of the frame which faces laterally outwards and is disposed vertically. The outer bend region has a lower surface disposed in the same horizontal plane as a lower surface of an inner region in the vicinity of the juncture of the projecting portion and the grid region. Thereby, when the base plate is placed on a horizontal planar surface, the peripheral frame region will rest on the horizontal surface along two lines of contact respectively at the bottom of the edge surface and at the lower surface at the juncture of the frame region and the grid region.

  4. An alternative method on quadratic programming problems

    NASA Astrophysics Data System (ADS)

    Dasril, Y.; Mohd, I. B.; Mustaffa, I.; Aminuddin, MMM.

    2015-05-01

    In this paper we proposed an alternative approach to find the optimum solution of quadratic programming problems (QPP) in its original form without additional information such as slack variable, surplus variable or artificial variable as done in other favourite methods. This approached is based on the violated constraints by the unconstrained optimum. The optimal solution of QPP obtained by searching from initial point to another point alongside of feasible region.

  5. Synthesis of bimetallic nanoshells by an improved electroless plating method.

    PubMed

    Liu, J B; Dong, W; Zhan, P; Wang, S Z; Zhang, J H; Wang, Z L

    2005-03-01

    In the Letter, we demonstrate an improved electroless plating method for the synthesis of bimetallic shell particles. The procedure involves a combination of surface reaction, seeding growth, and removal of supporting cores. We modified ammonical AgNO3 in ethanol with a controlled amount of HCHO in the seeding process and a uniform and relatively dense coverage of silver nanoparticle seeds on colloid cores was achieved. Following the second kind of metal plating, we extended this method to prepare continuous bimetallic core-shell and hollow particles with a submicrometer diameter. The morphologies of the bimetallic Cu/Ag and Pt/Ag particles were studied with transmission electron microscopy and scanning electron microscopy, and their crystallinity and chemical composition were confirmed by X-ray diffraction. The prepared materials may be of applied value in areas such as catalysis, optics, and plasmonics. PMID:15723456

  6. Linear transformation method to control flexural waves in thin plates.

    PubMed

    Liu, Yongquan; Ma, Zhaoyang; Su, Xianyue

    2016-08-01

    In this paper, the linear transformation method (LTM) to control flexural waves propagating in thin plates is presented. Unlike earlier studies, only a small number of homogeneous materials with no requirement of in-plane forces or pre-stress are needed, which tremendously simplifies the implementation of devices for flexural waves. An invisibility cloak with homogeneous materials is studied to confirm the validity of the present approach, and to show its imperfection due to impedance mismatch at interfaces. Required materials can be further simplified as layered isotropic materials using the effective medium theory. Finally, the LTM can be extended to the case of flexural waves propagating in anisotropic thin plates. The present method opens a promising avenue toward the realization of advanced structured shields and other devices. PMID:27586744

  7. Simplified 48-hour IMVic test: an agar plate method.

    PubMed

    Powers, E M; Latt, T G

    1977-09-01

    An agar plate method was developed for the performance of the IMVic (indole, methyl red, Voges-Proskauer, and citrate) tests in lieu of the conventional tubed liquid media. By modifying the composition of the media and adding agar, a single "X"-compartmented petri dish was prepared containing all four IMVic test media. Ease of performance and simplification of the test were achieved by inoculating all four media simultaneously from a single colony (single inoculum) on eosin-methylene blue agar. Tests with 87 cultures, representing 7 genera in the family Enterobacteriaceae, were completed with typical (correct) IMVic patterns for all cultures within 48 h. Parallel tests with conventional media showed that the agar plate method was superior, more sensitive, faster, and simpler to perform, and less time was required to identify Escherichia coli by 72 h. PMID:334074

  8. Purification of Carbon Nanotubes: Alternative Methods

    NASA Technical Reports Server (NTRS)

    Files, Bradley; Scott, Carl; Gorelik, Olga; Nikolaev, Pasha; Hulse, Lou; Arepalli, Sivaram

    2000-01-01

    Traditional carbon nanotube purification process involves nitric acid refluxing and cross flow filtration using surfactant TritonX. This is believed to result in damage to nanotubes and surfactant residue on nanotube surface. Alternative purification procedures involving solvent extraction, thermal zone refining and nitric acid refiuxing are used in the current study. The effect of duration and type of solvent to dissolve impurities including fullerenes and P ACs (polyaromatic compounds) are monitored by nuclear magnetic reasonance, high performance liquid chromatography, and thermogravimetric analysis. Thermal zone refining yielded sample areas rich in nanotubes as seen by scanning electric microscopy. Refluxing in boiling nitric acid seem to improve the nanotube content. Different procedural steps are needed to purify samples produced by laser process compared to arc process. These alternative methods of nanotube purification will be presented along with results from supporting analytical techniques.

  9. Stiffened plate bending analysis by the boundary element method

    NASA Astrophysics Data System (ADS)

    Fernandes, G. R.; Venturini, W. S.

    In this work, the plate bending formulation of the boundary element method (BEM) based on the Kirchhoff's hypothesis, is extended to the analysis of stiffened elements usually present in building floor structures. Particular integral representations are derived to take directly into account the interactions between the beams forming grid and surface elements. Equilibrium and compatibility conditions are automatically imposed by the integral equations, which treat this composite structure as a single body. Two possible procedures are shown for dealing with plate domain stiffened by beams. In the first, the beam element is considered as a stiffer region requiring therefore the discretization of two internal lines with two unknowns per node. In the second scheme, the number of degrees of freedom along the interface is reduced by two by assuming that the cross-section motion is defined by three independent components only.

  10. Alternative Test Methods for Electronic Parts

    NASA Technical Reports Server (NTRS)

    Plante, Jeannette

    2004-01-01

    It is common practice within NASA to test electronic parts at the manufacturing lot level to demonstrate, statistically, that parts from the lot tested will not fail in service using generic application conditions. The test methods and the generic application conditions used have been developed over the years through cooperation between NASA, DoD, and industry in order to establish a common set of standard practices. These common practices, found in MIL-STD-883, MIL-STD-750, military part specifications, EEE-INST-002, and other guidelines are preferred because they are considered to be effective and repeatable and their results are usually straightforward to interpret. These practices can sometimes be unavailable to some NASA projects due to special application conditions that must be addressed, such as schedule constraints, cost constraints, logistical constraints, or advances in the technology that make the historical standards an inappropriate choice for establishing part performance and reliability. Alternate methods have begun to emerge and to be used by NASA programs to test parts individually or as part of a system, especially when standard lot tests cannot be applied. Four alternate screening methods will be discussed in this paper: Highly accelerated life test (HALT), forward voltage drop tests for evaluating wire-bond integrity, burn-in options during or after highly accelerated stress test (HAST), and board-level qualification.

  11. Overview On Alternative Asbestos Control Method Research: Alternative Methods To Demolition

    EPA Science Inventory

    The Alternative Asbestos Control Method (AACM) is an experimental approach to building demolition. Unlike the NESHAP method, the AACM allows some regulated asbestos-containing material to remain in the building and a surfactant-water solution is used to suppress asbestos fibers ...

  12. 77 FR 31756 - Energy Conservation Program: Alternative Efficiency Determination Methods and Alternative Rating...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    ... Methods and Alternative Rating Methods: Public Meeting AGENCY: Office of Energy Efficiency and Renewable... proposed modifications to the regulations authorizing the use of alternative methods of determining energy... alternative methods of determining energy efficiency or energy consumption of various consumer products...

  13. Two Alternative Methods for Height Transformation

    NASA Astrophysics Data System (ADS)

    Kollo, Karin

    2008-03-01

    Geodesists have always been dealing with coordinate transformations. There exist various kinds of transformations, like three-dimensional (spatial datum) transformations, two-dimensional (horizontal datum) transformations and one-dimensional (eg, height) transformations. In this article we discuss height transformations. Height data is usually obtained by levelling. The problematic side of levelling is that this technique is very labour intensive and costly. Nowadays as well GPS measurements can be used, which are much faster and cheaper, but in order to use GPS measurements for height determination, we need a precise geoid model to transform GPS heights to heights above sea level. In this article two different approaches to this transformation are presented. At first, the affine transformation is discussed. The method is by nature linear, and employs the barycentric coordinates of the point, the height of which is going to be computed. Secondly, the method of fuzzy modelling is used. By these methods, the transformation surface is determined and the heights of desired points can be determined. As the input data, height information from the precise levelling campaign in Estonia is used. The computed values are tested against height information, gathered from the reference geoid model. The objectives of this research are acquiring insight into using alternative methods for height transformation as well as to statistically characterise the suitability of the proposed methods.

  14. Thermal diffusivity of nonflat plates using the flash method

    SciTech Connect

    Salazar, Agustin; Fuente, Raquel; Apinaniz, Estibaliz; Mendioroz, Arantza

    2011-01-15

    The flash method is the standard technique to measure the thermal diffusivity of solid samples. It consists of heating the front surface of an opaque sample by a brief light pulse and detecting the temperature evolution at its rear surface. The thermal diffusivity is obtained by measuring the time corresponding to the half maximum of the temperature rise, which only depends on the sample thickness and thermal diffusivity through a simple formula. Up to now, the flash method has been restricted to flat samples. In this work, we extend the flash method to measure the thermal diffusivity of nonflat samples. In particular, we focus on plates with cylindrical and spherical shapes. The theoretical model indicates that the same expression for flat samples can also be applied to cylindrical and spherical plates, except for extremely curved samples. Accordingly, a curvature limit for the application of the expression for flat samples is established. Flash measurements on lead foils of cylindrical shape confirm the validity of the model.

  15. An Alternative Method to Project Wind Patterns

    NASA Astrophysics Data System (ADS)

    Fadillioglu, Cagla; Kiyisuren, I. Cagatay; Collu, Kamil; Turp, M. Tufan; Kurnaz, M. Levent; Ozturk, Tugba

    2016-04-01

    Wind energy is one of the major clean and sustainable energy sources. Beside its various advantages, wind energy has a downside that its performance cannot be projected very accurately in the long-term. In this study, we offer an alternative method which can be used to determine the best location to install a wind turbine in a large area aiming maximum energy performance in the long run. For this purpose, a regional climate model (i.e. RegCM4.4) is combined with a software called Winds on Critical Streamline Surfaces (WOCSS) in order to identify wind patterns for any domains even in a changing climate. As a special case, Çanakkale region is examined due to the terrain profile having both coastal and mountainous features. WOCSS program was run twice for each month in the sample years in a double nested fashion, using the provisional RegCM4.4 wind data between years 2020 and 2040. Modified version of WOCSS provides terrain following flow surfaces and by processing those data, it makes a wind profile output for certain heights specified by the user. The computational time of WOCSS is also in reasonable range. Considering the lack of alternative methods for long-term wind performance projection, the model used in this study is a very good way for obtaining quick indications for wind performance taking the impact of the terrain effects into account. This research has been supported by Boǧaziçi University Research Fund Grant Number 10421.

  16. Alternative method of removing otoliths from sturgeon

    USGS Publications Warehouse

    Chalupnicki, Marc A.; Dittman, Dawn E.

    2016-01-01

    Extracting the otoliths (ear bones) from fish that have very thick skulls can be difficult and very time consuming. The common practice of making a transverse vertical incision on the top of the skull with a hand or electrical saw may damage the otolith if not performed correctly. Sturgeons (Acipenseridae) are one family in particular that have a very large and thick skull. A new laboratory method entering the brain cavity from the ventral side of the fish to expose the otoliths was easier than other otolith extraction methods found in the literature. Methods reviewed in the literature are designed for the field and are more efficient at processing large quantities of fish quickly. However, this new technique was designed to be more suited for a laboratory setting when time is not pressing and successful extraction from each specimen is critical. The success of finding and removing otoliths using this technique is very high and does not compromise the structure in any manner. This alternative technique is applicable to other similar fish species for extracting the otoliths.

  17. Alternative Method of Removing Otoliths from Sturgeon.

    PubMed

    Chalupnicki, Marc A; Dittman, Dawn E

    2016-01-01

    Extracting the otoliths (ear bones) from fish that have very thick skulls can be difficult and very time consuming. The common practice of making a transverse vertical incision on the top of the skull with a hand or electrical saw may damage the otolith if not performed correctly. Sturgeons (Acipenseridae) are one family in particular that have a very large and thick skull. A new laboratory method entering the brain cavity from the ventral side of the fish to expose the otoliths was easier than other otolith extraction methods found in the literature. Methods reviewed in the literature are designed for the field and are more efficient at processing large quantities of fish quickly. However, this new technique was designed to be more suited for a laboratory setting when time is not pressing and successful extraction from each specimen is critical. The success of finding and removing otoliths using this technique is very high and does not compromise the structure in any manner. This alternative technique is applicable to other similar fish species for extracting the otoliths. PMID:27403646

  18. 29 CFR 4211.23 - Approval of alternative method.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Approval of alternative method. 4211.23 Section 4211.23... Subject to PBGC Approval § 4211.23 Approval of alternative method. (a) General. The PBGC shall approve an alternative allocation method or modification to an allocation method if the PBGC determines that adoption...

  19. 29 CFR 4211.23 - Approval of alternative method.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Approval of alternative method. 4211.23 Section 4211.23... Subject to PBGC Approval § 4211.23 Approval of alternative method. (a) General. The PBGC shall approve an alternative allocation method or modification to an allocation method if the PBGC determines that adoption...

  20. 29 CFR 4211.23 - Approval of alternative method.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Approval of alternative method. 4211.23 Section 4211.23... Subject to PBGC Approval § 4211.23 Approval of alternative method. (a) General. The PBGC shall approve an alternative allocation method or modification to an allocation method if the PBGC determines that adoption...

  1. 29 CFR 4211.23 - Approval of alternative method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Approval of alternative method. 4211.23 Section 4211.23... Subject to PBGC Approval § 4211.23 Approval of alternative method. (a) General. The PBGC shall approve an alternative allocation method or modification to an allocation method if the PBGC determines that adoption...

  2. Practical method for diffusion welding of steel plate in air.

    NASA Technical Reports Server (NTRS)

    Moore, T. J.; Holko, K. H.

    1972-01-01

    Description of a simple and easily applied method of diffusion welding steel plate in air which does not require a vacuum furnace or hot press. The novel feature of the proposed welding method is that diffusion welds are made in air with deadweight loading. In addition, the use of an autogenous (self-generated) surface-cleaning principle (termed 'auto-vac cleaning') to reduce the effects of surface oxides that normally hinder diffusion welding is examined. A series of nine butt joints were diffusion welded in thick sections of AISI 1020 steel plate. Diffusion welds were attempted at three welding temperatures (1200, 1090, and 980 C) using a deadweight pressure of 34,500 N/sq m (5 psi) and a two-hour hold time at temperature. Auto-vac cleaning operations prior to welding were also studied for the same three temperatures. Results indicate that sound welds were produced at the two higher temperatures when the joints were previously fusion seal welded completely around the periphery. Also, auto-vac cleaning at 1200 C for 2-1/2 hours prior to diffusion welding was highly beneficial, particularly when subsequent welding was accomplished at 1090 C.

  3. Recommendations for Developing Alternative Test Methods for Developmental Neurotoxicity

    EPA Science Inventory

    There is great interest in developing alternative methods for developmental neurotoxicity testing (DNT) that are cost-efficient, use fewer animals and are based on current scientific knowledge of the developing nervous system. Alternative methods will require demonstration of the...

  4. Maggot Debridement: An Alternative Method for Debridement

    PubMed Central

    Gottrup, Finn; Jørgensen, Bo

    2011-01-01

    Debridement is an essential component to promote healing in a problem wound. Several techniques are available including maggot debridement therapy (MDT). Objective: To describe the efficacy of MDT for treating problem wound especially diabetic foot ulcers. Methods: The topic is elucidated from different points of view: the mode of action, when to use, use in a practice, clinical results, and discussing the problem of creating evidence for the clinical effect. Results: Literature and own results demonstrate that MDT is a safe method with few side effects. Maggot debridement therapy is as good as or better than conventional often surgical debridement, is more selective than surgical debridement, decreases time to healing and stay of patients in the ward, and may decrease the risk of major amputations. However, the evidence of these effects of MDT on the highest level is presently lacking. A detailed description of how to use MDT in practice is provided including a visual demonstration in a video. Conclusion: In spite of lacking clinical evidence, MDT clinical experience strongly suggests that this technique is effective and safe. It can be used for most types of problem wounds, but our indication is primarily diabetic foot ulcers, because of its selectivity for debriding necrotic dead tissue. It may be a valuable alternative surgical/sharp debridement. PMID:21776326

  5. Alternative Energy Sources in Seismic Methods

    NASA Astrophysics Data System (ADS)

    Tün, Muammer; Pekkan, Emrah; Mutlu, Sunay; Ecevitoğlu, Berkan

    2015-04-01

    When the suitability of a settlement area is investigated, soil-amplification, liquefaction and fault-related hazards should be defined, and the associated risks should be clarified. For this reason, soil engineering parameters and subsurface geological structure of a new settlement area should be investigated. Especially, faults covered with quaternary alluvium; thicknesses, shear-wave velocities and geometry of subsurface sediments could lead to a soil amplification during an earthquake. Likewise, changes in shear-wave velocities along the basin are also very important. Geophysical methods can be used to determine the local soil properties. In this study, use of alternative seismic energy sources when implementing seismic reflection, seismic refraction and MASW methods in the residential areas of Eskisehir/Turkey, were discussed. Our home developed seismic energy source, EAPSG (Electrically-Fired-PS-Gun), capable to shoot 2x24 magnum shotgun cartridges at once to generate P and S waves; and our home developed WD-500 (500 kg Weight Drop) seismic energy source, mounted on a truck, were developed under a scientific research project of Anadolu University. We were able to reach up to penetration depths of 1200 m for EAPSG, and 800 m for WD-500 in our seismic reflection surveys. WD-500 seismic energy source was also used to perform MASW surveys, using 24-channel, 10 m apart, 4.5 Hz vertical geophone configuration. We were able to reach 100 m of penetration depth in MASW surveys.

  6. Alternating direction method for balanced image restoration.

    PubMed

    Xie, Shoulie; Rahardja, Susanto

    2012-11-01

    This paper presents an efficient algorithm for solving a balanced regularization problem in the frame-based image restoration. The balanced regularization is usually formulated as a minimization problem, involving an l(2) data-fidelity term, an l(1) regularizer on sparsity of frame coefficients, and a penalty on distance of sparse frame coefficients to the range of the frame operator. In image restoration, the balanced regularization approach bridges the synthesis-based and analysis-based approaches, and balances the fidelity, sparsity, and smoothness of the solution. Our proposed algorithm for solving the balanced optimal problem is based on a variable splitting strategy and the classical alternating direction method. This paper shows that the proposed algorithm is fast and efficient in solving the standard image restoration with balanced regularization. More precisely, a regularized version of the Hessian matrix of the l(2) data-fidelity term is involved, and by exploiting the related fast tight Parseval frame and the special structures of the observation matrices, the regularized Hessian matrix can perform quite efficiently for the frame-based standard image restoration applications, such as circular deconvolution in image deblurring and missing samples in image inpainting. Numerical simulations illustrate the efficiency of our proposed algorithm in the frame-based image restoration with balanced regularization. PMID:22752137

  7. Method for Reduction of Silver Biocide Plating on Metal Surfaces

    NASA Technical Reports Server (NTRS)

    Steele, John; Nalette, Timothy; Beringer, Durwood

    2013-01-01

    Silver ions in aqueous solutions (0.05 to 1 ppm) are used for microbial control in water systems. The silver ions remain in solution when stored in plastic containers, but the concentration rapidly decreases to non-biocidal levels when stored in metal containers. The silver deposits onto the surface and is reduced to non-biocidal silver metal when it contacts less noble metal surfaces, including stainless steel, titanium, and nickel-based alloys. Five methods of treatment of contact metal surfaces to deter silver deposition and reduction are proposed: (1) High-temperature oxidation of the metal surface; (2) High-concentration silver solution pre-treatment; (3) Silver plating; (4) Teflon coat by vapor deposition (titanium only); and (5) A combination of methods (1) and (2), which proved to be the best method for the nickel-based alloy application. The mechanism associated with surface treatments (1), (2), and (5) is thought to be the development of a less active oxide layer that deters ionic silver deposition. Mechanism (3) is an attempt to develop an equilibrium ionic silver concentration via dissolution of metallic silver. Mechanism (4) provides a non-reactive barrier to deter ionic silver plating. Development testing has shown that ionic silver in aqueous solution was maintained at essentially the same level of addition (0.4 ppm) for up to 15 months with method (5) (a combination of methods (1) and (2)), before the test was discontinued for nickel-based alloys. Method (1) resulted in the maintenance of a biocidal level (approximately 0.05 ppm) for up to 10 months before that test was discontinued for nickel-based alloys. Methods (1) and (2) used separately were able to maintain ionic silver in aqueous solution at essentially the same level of addition (0.4 ppm) for up to 10 months before the test was discontinued for stainless steel alloys. Method (3) was only utilized for titanium alloys, and was successful at maintaining ionic silver in aqueous solution at

  8. Models of convection-driven tectonic plates - A comparison of methods and results

    NASA Technical Reports Server (NTRS)

    King, Scott D.; Gable, Carl W.; Weinstein, Stuart A.

    1992-01-01

    Recent numerical studies of convection in the earth's mantle have included various features of plate tectonics. This paper describes three methods of modeling plates: through material properties, through force balance, and through a thin power-law sheet approximation. The results obtained are compared using each method on a series of simple calculations. From these results, scaling relations between the different parameterizations are developed. While each method produces different degrees of deformation within the surface plate, the surface heat flux and average plate velocity agree to within a few percent. The main results are not dependent upon the plate modeling method and herefore are representative of the physical system modeled.

  9. Method of evaluating thermal diffusivity near lossy boundaries as an alternative to the Parker method

    NASA Astrophysics Data System (ADS)

    Ringermacher, Harry I.

    2013-04-01

    We describe an analysis of a flash thermographic method to measure thermal diffusivity that is particularly insensitive to heat loss mechanisms near thermal boundaries. This approach is an alternative to the "Parker method" which requires that a plate-like region subject to a uniform energy flux must reach a maximum constant temperature in order to obtain an accurate measurement of thermal diffusivity at the half-temperature point in time. The present approach relies on evaluating another unique point, the inflection point, of the same back-side thermal response curve as Parker's or, from the front side, using a contrast versus time curve in the sample region of interest. This inflection point occurs so early in the response history that little heat loss, for example, near heat-sink boundaries or surface convection, is expressed. Since the method is insensitive to the achieved temperature, it is also insensitive to surface emissivity variations.

  10. Alternative methods for the design of jet engine control systems

    NASA Technical Reports Server (NTRS)

    Sain, M. K.; Leake, R. J.; Basso, R.; Gejji, R.; Maloney, A.; Seshadri, V.

    1976-01-01

    Various alternatives to linear quadratic design methods for jet engine control systems are discussed. The main alternatives are classified into two broad categories: nonlinear global mathematical programming methods and linear local multivariable frequency domain methods. Specific studies within these categories include model reduction, the eigenvalue locus method, the inverse Nyquist method, polynomial design, dynamic programming, and conjugate gradient approaches.

  11. Methods for generating hydroelectric power development alternatives

    SciTech Connect

    Chang, Shoou-yuh; Liaw, Shu-liang; Sale, M.J.; Railsback, S.F.

    1989-01-01

    Hydropower development on large rivers can result in a number of environmental impacts, including potential reductions in dissolved oxygen (DO) concentrations. This study presents a methodology for generating different hydropower development alternatives for evaluation. This methodology employs a Streeter-Phelps model to simulate DO, and the Bounded Implicit Enumeration algorithm to solve an optimization model formulated to maximize hydroelectric energy production subject to acceptable DO limits. The upper Ohio River basin was used to illustrate the use and characteristics of the methodology. The results indicate that several alternatives which meet the specified DO constraints can be generated efficiently, meeting both power and environmental objectives. 17 refs., 2 figs., 1 tab.

  12. Electrodeposited Zinc-Nickel as an Alternative to Cadmium Plating for Aerospace Application

    NASA Technical Reports Server (NTRS)

    Mcmillan, V. C.

    1991-01-01

    Corrosion evaluation studies were conducted on 4130 alloy steel samples coated with electrodeposited zinc-nickel and samples coated with electrodeposited cadmium. The zinc nickel was deposited by the selection electrochemical metallizing process. These coated samples were exposed to a 5-percent salt fog environment at 35 plus or minus 2 C for a period ranging from 96 to 240 hours. An evaluation of the effect of dichromate coatings on the performance of each plating was conducted. The protection afforded by platings with a dichromate seal was compared to platings without the seal. During the later stages of testing, deposit adhesion and the potential for hydrogen entrapment were also evaluated.

  13. Inverse methods for modeling non-rigid plate kinematics: Application to mesozoic plate reconstructions of the Central Atlantic

    NASA Astrophysics Data System (ADS)

    Kneller, Erik A.; Johnson, Christopher A.; Karner, Garry D.; Einhorn, Jesse; Queffelec, Thomas A.

    2012-12-01

    Published plate reconstructions commonly show significant differences in initial plate configuration and syn-extensional opening directions. The variability of published models is primarily due to the difficulty associated with restoring crustal stretching history. Here we present an inverse non-rigid kinematic method that inverts plate motion and present day crustal thickness to approximate the history of bulk lateral strain and crustal thinning associated with lithospheric stretching. The kinematic link between plate motion and bulk crustal thickness that is used with this method is based on insights obtained from geodynamic models. We implement this approach in open source kinematic modeling software and apply it to test new Early Mesozoic plate kinematic models of the Central Atlantic. This application shows that the patterns of stretching inferred from the syn-rift basins of the Newark Supergroup can be explained if (1) syn-rift Euler pole flow lines were parallel to the Grand Banks transform margin and (2) initial formation of the East Coast Margin Igneous Province was coincident with the formation of the Central Atlantic Magmatic Province. These syn-rift to breakup models of the Central Atlantic lead to better constrained models of early seafloor spreading that show full spreading velocities in the ultraslow regime and within the transition from ultraslow to slow spreading regimes.

  14. Perforated plates for cryogenic regenerators and method of fabrication

    DOEpatents

    Hendricks, J.B.

    1994-03-29

    Perforated plates having very small holes with a uniform diameter throughout the plate thickness are prepared by a [open quotes]wire drawing[close quotes] process in which a billet of sacrificial metal is disposed in an extrusion can of the plate metal, and the can is extruded and restacked repeatedly, converting the billet to a wire of the desired hole diameter. At final size, the rod is then sliced into wafers, and the wires are removed by selective etching. This process is useful for plate metals of interest for high performance regenerator applications, in particular, copper, niobium, molybdenum, erbium, and other rare earth metals. Er[sub 3]Ni, which has uniquely favorable thermophysical properties for such applications, may be incorporated in regions of the plates by providing extrusion cans containing erbium and nickel metals in a stacked array with extrusion cans of the plate metal, which may be copper. The array is heated to convert the erbium and nickel metals to Er[sub 3]Ni. Perforated plates having two sizes of perforations, one of which is small enough for storage of helium, are also disclosed. 10 figures.

  15. Perforated plates for cryogenic regenerators and method of fabrication

    DOEpatents

    Hendricks, John B.

    1994-01-01

    Perforated plates (10) having very small holes (14) with a uniform diameter throughout the plate thickness are prepared by a "wire drawing" process in which a billet of sacrificial metal is disposed in an extrusion can of the plate metal, and the can is extruded and restacked repeatedly, converting the billet to a wire of the desired hole diameter. At final size, the rod is then sliced into wafers, and the wires are removed by selective etching. This process is useful for plate metals of interest for high performance regenerator applications, in particular, copper, niobium, molybdenum, erbium, and other rare earth metals. Er.sub.3 Ni, which has uniquely favorable thermophysical properties for such applications, may be incorporated in regions of the plates by providing extrusion cans (20) containing erbium and nickel metals in a stacked array (53) with extrusion cans of the plate metal, which may be copper. The array is heated to convert the erbium and nickel metals to Er.sub.3 Ni. Perforated plates having two sizes of perforations (38, 42), one of which is small enough for storage of helium, are also disclosed.

  16. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, E.T.

    1997-03-11

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorus acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution. 1 fig.

  17. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, Erhard T.

    1997-01-01

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorous acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution.

  18. 27 CFR 26.331 - Alternate methods or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... into the United States from Puerto Rico or the Virgin Islands who desires to use an alternate method or procedure in lieu of a method or procedure prescribed by this part shall file application, in triplicate... use such alternate method or procedure, a separate application shall be submitted for each....

  19. 49 CFR 218.79 - Alternative methods of protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Alternative methods of protection. 218.79 Section....79 Alternative methods of protection. Instead of providing protection for occupied camp cars in accordance with § 218.75 or § 218.77, the following methods of protection may be used: (a) When occupied...

  20. 49 CFR 218.29 - Alternate methods of protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Alternate methods of protection. 218.29 Section....29 Alternate methods of protection. Instead of providing blue signal protection for workers in accordance with § 218.27, the following methods for blue signal protection may be used: (a) When workers...

  1. Method and apparatus for enhancing microchannel plate data

    DOEpatents

    Thoe, Robert S.

    1987-01-01

    A method and apparatus for determining centroid channel locations is disclosed for use in a system activated by one or more multichannel plates (16,18) and including a linear diode array (24) providing channels of information 1, 2, . . . , n, . . . , N containing signal amplitudes A.sub.n. A source of analog A.sub.n signals (40), and a source of digital clock signals n (48), are provided. Non-zero A.sub.n values are detected in a discriminator (42). A digital signal representing p, the value of n immediately preceding that whereat A.sub.n takes its first non-zero value, is generated in a scaler (50). The analog A.sub.n signals are converted to digital in an analog to digital converter (44). The digital A.sub.n signals are added to produce a digital .SIGMA.A.sub.n signal in a full adder (46). Digital 1, 2, . . . , m signals representing the number of non-zero A.sub.n are produced by a discriminator pulse counter (52). Digital signals representing 1 A.sub.p+ 1, 2 A.sub.p+2, . . . , m A.sub.p+m are produced by pairwise multiplication in multiplier (54). These signals are added in multiplier summer (56) to produce a digital .SIGMA.nA.sub.n -p.SIGMA.A.sub.n signal. This signal is divided by the digital .SIGMA.A.sub.n signal in divider (58) to provide a digital (.SIGMA.nA.sub.n /.SIGMA.A.sub.n) -p signal. Finally, this last signal is added to the digital p signal in an offset summer (60) to provide .SIGMA.nA.sub.n /.SIGMA.A.sub.n, the centroid channel locations.

  2. Method and apparatus for enhancing microchannel plate data

    DOEpatents

    Thoe, R.S.

    1983-10-24

    A method and apparatus for determining centroid channel locations are disclosed for use in a system activated by one or more multichannel plates and including a linear diode array providing channels of information 1, 2, ...,n, ..., N containing signal amplitudes A/sub n/. A source of analog A/sub n/ signals, and a source of digital clock signals n, are provided. Non-zero A/sub n/ values are detected in a discriminator. A digital signal representing p, the value of n immediately preceding that whereat A/sub n/ takes its first non-zero value, is generated in a scaler. The analog A/sub n/ signals are converted to digital in an analog to digital converter. The digital A/sub n/ signals are added to produce a digital ..sigma..A/sub n/ signal in a full adder. Digital 1, 2, ..., m signals representing the number of non-zero A/sub n/ are produced by a discriminator pulse counter. Digital signals representing 1 A/sub p+1/, 2 A/sub p+2/, ..., m A/sub p+m/ are produced by pairwise multiplication in multiplier. These signal are added in multiplier summer to produce a digital ..sigma..nA/sub n/ - p..sigma..A/sub n/ signal. This signal is divided by the digital ..sigma..A/sub n/ signal in divider to provide a digital (..sigma..nA/sub n//..sigma..A/sub n/) -p signal. Finally, this last signal is added to the digital p signal in an offset summer to provide ..sigma..nA/sub n//..sigma..A/sub n/, the centroid channel locations.

  3. 7 CFR 3565.455 - Alternative disposition methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Alternative disposition methods. 3565.455 Section 3565.455 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE....455 Alternative disposition methods. The Agency, in its sole discretion, may choose to obtain...

  4. 27 CFR 72.61 - Alternative methods of sale.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2014-04-01 2014-04-01 false Alternative methods of sale. 72.61 Section 72.61 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... PROPERTY Administrative Sale or Disposition of Personal Property § 72.61 Alternative methods of sale....

  5. 49 CFR 218.79 - Alternative methods of protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Alternative methods of protection. 218.79 Section 218.79 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD....79 Alternative methods of protection. Instead of providing protection for occupied camp cars...

  6. 27 CFR 72.61 - Alternative methods of sale.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2013-04-01 2013-04-01 false Alternative methods of sale. 72.61 Section 72.61 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... PROPERTY Administrative Sale or Disposition of Personal Property § 72.61 Alternative methods of sale....

  7. 49 CFR 218.79 - Alternative methods of protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Alternative methods of protection. 218.79 Section 218.79 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD....79 Alternative methods of protection. Instead of providing protection for occupied camp cars...

  8. 26 CFR 403.55 - Alternative methods of sale.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 18 2011-04-01 2011-04-01 false Alternative methods of sale. 403.55 Section 403.55 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND... Alternative methods of sale. When personal property forfeited administratively is to be sold, the...

  9. 49 CFR 218.79 - Alternative methods of protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Alternative methods of protection. 218.79 Section 218.79 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD....79 Alternative methods of protection. Instead of providing protection for occupied camp cars...

  10. 49 CFR 218.79 - Alternative methods of protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Alternative methods of protection. 218.79 Section 218.79 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD....79 Alternative methods of protection. Instead of providing protection for occupied camp cars...

  11. 7 CFR 3565.455 - Alternative disposition methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Alternative disposition methods. 3565.455 Section 3565.455 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE....455 Alternative disposition methods. The Agency, in its sole discretion, may choose to obtain...

  12. 7 CFR 3565.455 - Alternative disposition methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Alternative disposition methods. 3565.455 Section 3565.455 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE....455 Alternative disposition methods. The Agency, in its sole discretion, may choose to obtain...

  13. 26 CFR 403.55 - Alternative methods of sale.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 18 2013-04-01 2013-04-01 false Alternative methods of sale. 403.55 Section 403.55 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND... Alternative methods of sale. When personal property forfeited administratively is to be sold, the...

  14. 27 CFR 72.61 - Alternative methods of sale.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2012-04-01 2011-04-01 true Alternative methods of sale. 72.61 Section 72.61 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Administrative Sale or Disposition of Personal Property § 72.61 Alternative methods of sale. (a) Sale by...

  15. 27 CFR 72.61 - Alternative methods of sale.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Alternative methods of sale. 72.61 Section 72.61 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... PROPERTY Administrative Sale or Disposition of Personal Property § 72.61 Alternative methods of sale....

  16. 7 CFR 3565.455 - Alternative disposition methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Alternative disposition methods. 3565.455 Section 3565.455 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE....455 Alternative disposition methods. The Agency, in its sole discretion, may choose to obtain...

  17. 77 FR 43827 - International Workshop on Alternative Methods for Leptospira

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-26

    ...The NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM) announces an ``International Workshop on Alternative Methods for Leptospira Vaccine Potency Testing: State of the Science and the Way Forward.'' This workshop, the second in a series of specialized vaccine workshops, will review recent advances and innovations in science and technology that can be......

  18. 27 CFR 27.221 - Alternate methods or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Miscellaneous Provisions § 27.221 Alternate methods or procedures. (a) Application. An importer who desires to... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods...

  19. Alternate Conceptions of Preservice Elementary Teachers: The Itakura Method

    ERIC Educational Resources Information Center

    Isabelle, Aaron D.; de Groot, Cornelis

    2008-01-01

    In this study, we determined the effectiveness of the inquiry-based Itakura method for mediating alternate conceptions of preservice elementary teachers (N = 38) in an integrated mathematics, science, and technology methods course. We investigated alternate conceptions in the expansion of solids due to heating. There was a significant increase in…

  20. Fuel cell collector plate and method of fabrication

    DOEpatents

    Braun, James C.; Zabriskie, Jr., John E.; Neutzler, Jay K.; Fuchs, Michel; Gustafson, Robert C.

    2001-01-01

    An improved molding composition is provided for compression molding or injection molding a current collector plate for a polymer electrolyte membrane fuel cell. The molding composition is comprised of a polymer resin combined with a low surface area, highly-conductive carbon and/or graphite powder filler. The low viscosity of the thermoplastic resin combined with the reduced filler particle surface area provide a moldable composition which can be fabricated into a current collector plate having improved current collecting capacity vis-a-vis comparable fluoropolymer molding compositions.

  1. Irradiated homologous tarsal plate banking: a new alternative in eyelid reconstruction. Part II. Human data

    SciTech Connect

    Jordan, D.R.; Tse, D.T.; Anderson, R.L.; Hansen, S.O. )

    1990-01-01

    Reconstruction of full thickness eyelid defects requires the correction of both posterior lamella (tarsus, conjunctiva) and anterior lamella (skin, muscle). Irradiated homologous tarsal plate provides a structured framework for the lid reconstruction, and is incorporated nicely into the normal lid anatomy.

  2. Alternative Inspection Methods for Single Shell Tanks

    SciTech Connect

    Peters, Timothy J.; Alzheimer, James M.; Hurley, David E.

    2010-01-19

    This document was prepared to provide evaluations and recommendations regarding nondestructive evaluation methods that might be used to determine cracks and bowing in the ceiling of waste storage tanks on the Hanford site. The goal was to determine cracks as small as 1/16 in. wide in the ceiling, and bowing as small as 0.25 in. This report describes digital video camera methods that can be used to detect a crack in the ceiling of the dome, and methods for determining the surface topography of the ceiling in the waste storage tanks to detect localized movements in the surface. A literature search, combined with laboratory testing, comprised this study.

  3. Method for in-situ nondestructive measurement of Young's modulus of plate structures

    NASA Technical Reports Server (NTRS)

    Huang, Jerry Qixin (Inventor); Perez, Robert J. (Inventor); DeLangis, Leo M. (Inventor)

    2003-01-01

    A method for determining stiffness of a composite laminate plate entails disposing a device for generating an acoustical pulse against a surface of the plate and disposing a detecting device against the same surface spaced a known distance from the pulse-generating device, and using the pulse-generating device to emit a pulse so as to create an extensional wave in the plate. The detecting device is used to determine a time of flight of the wave over the known distance, and the wave velocity is calculated. A Young's modulus of the plate is determined based on the wave velocity. Methods for both anisotropic and quasi-isotropic laminates are disclosed.

  4. Alternate cleaning methods for LCCAs. Final report

    SciTech Connect

    Adams, B.E.

    1993-04-01

    The purpose of this project was to evaluate DI water followed by isopropyl alcohol (IPA) cleaning and no cleaning of leadless chip carriers (LCCs). Both environmentally safe methods were to be tested against the current chlorofluorocarbon (CFC) material cleaning baseline. Several experiments were run to compare production and electrical yields of LCCs cleaned by all three methods. The critical process steps most affected by cleaning were wire bonding, sealing, particle induced noise detection (PIND), moisture content, and electrical. Yields for the experimental lots cleaned by CFC, DI water plus IPA, and no cleaning were 56%, 72%, and 75%, respectively. The overall results indicated that vapor degreasing/ultrasonic cleaning in CFCs could be replaced by the aqueous method. No cleaning could also be considered if an effective dry method of particle removal could be developed.

  5. Alternative methods to determine headwater benefits

    SciTech Connect

    Bao, Y.S.; Perlack, R.D.; Sale, M.J.

    1997-11-10

    In 1992, the Federal Energy Regulatory Commission (FERC) began using a Flow Duration Analysis (FDA) methodology to assess headwater benefits in river basins where use of the Headwater Benefits Energy Gains (HWBEG) model may not result in significant improvements in modeling accuracy. The purpose of this study is to validate the accuracy and appropriateness of the FDA method for determining energy gains in less complex basins. This report presents the results of Oak Ridge National Laboratory`s (ORNL`s) validation of the FDA method. The validation is based on a comparison of energy gains using the FDA method with energy gains calculated using the MWBEG model. Comparisons of energy gains are made on a daily and monthly basis for a complex river basin (the Alabama River Basin) and a basin that is considered relatively simple hydrologically (the Stanislaus River Basin). In addition to validating the FDA method, ORNL was asked to suggest refinements and improvements to the FDA method. Refinements and improvements to the FDA method were carried out using the James River Basin as a test case.

  6. Computed radiography imaging plates and associated methods of manufacture

    DOEpatents

    Henry, Nathaniel F.; Moses, Alex K.

    2015-08-18

    Computed radiography imaging plates incorporating an intensifying material that is coupled to or intermixed with the phosphor layer, allowing electrons and/or low energy x-rays to impart their energy on the phosphor layer, while decreasing internal scattering and increasing resolution. The radiation needed to perform radiography can also be reduced as a result.

  7. Evaluation of Alternate Surface Passivation Methods (U)

    SciTech Connect

    Clark, E

    2005-05-31

    Stainless steel containers were assembled from parts passivated by four commercial vendors using three passivation methods. The performance of these containers in storing hydrogen isotope mixtures was evaluated by monitoring the composition of initially 50% H{sub 2} 50% D{sub 2} gas with time using mass spectroscopy. Commercial passivation by electropolishing appears to result in surfaces that do not catalyze hydrogen isotope exchange. This method of surface passivation shows promise for tritium service, and should be studied further and considered for use. On the other hand, nitric acid passivation and citric acid passivation may not result in surfaces that do not catalyze the isotope exchange reaction H{sub 2} + D{sub 2} {yields} 2HD. These methods should not be considered to replace the proprietary passivation processes of the two current vendors used at the Savannah River Site Tritium Facility.

  8. Method of obtaining intensified image from developed photographic films and plates

    NASA Technical Reports Server (NTRS)

    Askins, B. S. (Inventor)

    1978-01-01

    A method is explained of obtaining intensified images from silver images on developed photographic films and plates. The steps involve converting silver of the developed film or plate to a radioactive compound by treatment with an aqueous alkaline solution of an organo-S35 compound; placing the treated film or plate in direct contact with a receiver film which is then exposed by radiation from the activated film; and developing and fixing the resulting intensified image on the receiver film.

  9. PID techniques: Alternatives to RICH methods

    NASA Astrophysics Data System (ADS)

    Va'vra, J.

    2011-05-01

    In this review article we discuss the recent progress in PID techniques other than the RICH methods. In particular we mention the recent progress in the Transition Radiation Detector (TRD), d E/d x cluster counting, and Time of Flight (TOF) techniques. Invited talk at RICH 2010, May 5, Cassis, France

  10. Creating Alternative Methods for Educational Evaluation.

    ERIC Educational Resources Information Center

    Smith, Nick L.

    1981-01-01

    A project supported by the National Institute of Education is adapting evaluation procedures from such areas as philosophy, geography, operations research, journalism, film criticism, and other areas. The need for such methods is reviewed, as is the context in which they function, and their contributions to evaluation methodology. (Author/GK)

  11. ALTERNATIVE IONIZATION METHODS FOR PARTICLE MASS SPECTROMETRY

    EPA Science Inventory

    The objective of this project is to enhance the capabilities of a real-time airborne particle mass spectrometer by implementing matrix-independent methods for sample ionization. The enhancements should result in improved sensitivity for trace substances and, more importantly, per...

  12. 3He alternative technologies: 1. Application of neutron image plate detector for powder diffractometry

    NASA Astrophysics Data System (ADS)

    Shaikh, A. M.; Krishna, P. S. R.; Shinde, A. B.

    2012-06-01

    Neutron image plate was used for recording powder diffraction pattern from a polycrystalline Fe rod, mounted on the High Q Diffractometer at Dhruva reactor and using neutron beam of λ = 0.783 Å and Φ = 3 × 105 n/cm2/sec. The Bragg peaks were sharp and well resolved. The overall resolution (Δ2θ/2θ) value was found be ˜0.025.

  13. {sup 3}He alternative technologies: 1. Application of neutron image plate detector for powder diffractometry

    SciTech Connect

    Shaikh, A. M.; Krishna, P. S. R.; Shinde, A. B.

    2012-06-05

    Neutron image plate was used for recording powder diffraction pattern from a polycrystalline Fe rod, mounted on the High Q Diffractometer at Dhruva reactor and using neutron beam of {lambda}= 0.783 A and {Phi}= 3 x 10{sup 5} n/cm{sup 2}/sec. The Bragg peaks were sharp and well resolved. The overall resolution ({Delta}2{theta}/2{theta}) value was found be {approx}0.025.

  14. Coupling equivalent plate and finite element formulations in multiple-method structural analyses

    NASA Technical Reports Server (NTRS)

    Giles, Gary L.; Norwood, Keith

    1994-01-01

    A coupled multiple-method analysis procedure for use late in conceptual design or early in preliminary design of aircraft structures is described. Using this method, aircraft wing structures are represented with equivalent plate models, and structural details such as engine/pylon structure, landing gear, or a 'stick' model of a fuselage are represented with beam finite element models. These two analysis methods are implemented in an integrated multiple-method formulation that involves the assembly and solution of a combined set of linear equations. The corresponding solution vector contains coefficients of the polynomials that describe the deflection of the wing and also the components of translations and rotations at the joints of the beam members. Two alternative approaches for coupling the methods are investigated; one using transition finite elements and the other using Lagrange multipliers. The coupled formulation is applied to the static analysis and vibration analysis of a conceptual design model of a fighter aircraft. The results from the coupled method are compared with corresponding results from an analysis in which the entire model is composed of finite elements.

  15. Alternative haplotype construction methods for genomic evaluation.

    PubMed

    Jónás, Dávid; Ducrocq, Vincent; Fouilloux, Marie-Noëlle; Croiseau, Pascal

    2016-06-01

    Genomic evaluation methods today use single nucleotide polymorphism (SNP) as genomic markers to trace quantitative trait loci (QTL). Today most genomic prediction procedures use biallelic SNP markers. However, SNP can be combined into short, multiallelic haplotypes that can improve genomic prediction due to higher linkage disequilibrium between the haplotypes and the linked QTL. The aim of this study was to develop a method to identify the haplotypes, which can be expected to be superior in genomic evaluation, as compared with either SNP or other haplotypes of the same size. We first identified the SNP (termed as QTL-SNP) from the bovine 50K SNP chip that had the largest effect on the analyzed trait. It was assumed that these SNP were not the causative mutations and they merely indicated the approximate location of the QTL. Haplotypes of 3, 4, or 5 SNP were selected from short genomic windows surrounding these markers to capture the effect of the QTL. Two methods described in this paper aim at selecting the most optimal haplotype for genomic evaluation. They assumed that if an allele has a high frequency, its allele effect can be accurately predicted. These methods were tested in a classical validation study using a dairy cattle population of 2,235 bulls with genotypes from the bovine 50K SNP chip and daughter yield deviations (DYD) on 5 dairy cattle production traits. Combining the SNP into haplotypes was beneficial with all tested haplotypes, leading to an average increase of 2% in terms of correlations between DYD and genomic breeding value estimates compared with the analysis when the same SNP were used individually. Compared with haplotypes built by merging the QTL-SNP with its flanking SNP, the haplotypes selected with the proposed criteria carried less under- and over-represented alleles: the proportion of alleles with frequencies <1 or >40% decreased, on average, by 17.4 and 43.4%, respectively. The correlations between DYD and genomic breeding value

  16. ALTERNATIVE ASBESTOS CONTROL METHOD (AACM) RESEARCH - BALTIMORE, MD

    EPA Science Inventory

    This presentation describes the status to date of the Alternative Asbestos Control Method research, which is intended as a possible alternative technology for use in the demolition of buildings that contain asbestos and are covered under the regulatory requirements of the Asbesto...

  17. Satellite Seminars: An Alternative Method for Extension Educators?

    ERIC Educational Resources Information Center

    Kiernan, N. E.; And Others

    1995-01-01

    Satellite seminars in grain and forage crop production and pest management were conducted for a large, geographically dispersed audience of farmers and agribusiness persons to test the feasibility of an alternative delivery method in extension. Results of a formative evaluation revealed it is feasible to create an alternative model. (LZ)

  18. Particle response to shock waves in solids: dynamic witness plate/PIV method for detonations

    NASA Astrophysics Data System (ADS)

    Murphy, Michael J.; Adrian, Ronald J.

    2007-08-01

    Studies using transparent, polymeric witness plates consisting of polydimethlysiloxane (PDMS) have been conducted to measure the output of exploding bridge wire (EBW) detonators and exploding foil initiators (EFI). Polymeric witness plates are utilized to alleviate particle response issues that arise in gaseous flow fields containing shock waves and to allow measurements of shock-induced material velocities to be made using particle image velocimetry (PIV). Quantitative comparisons of velocity profiles across the shock waves in air and in PDMS demonstrate the improved response achieved by the dynamic witness plate method. Schlieren photographs complement the analysis through direct visualization of detonator-induced shock waves in the witness plates.

  19. Alternative methods for characterization of extracellular vesicles.

    PubMed

    Momen-Heravi, Fatemeh; Balaj, Leonora; Alian, Sara; Tigges, John; Toxavidis, Vasilis; Ericsson, Maria; Distel, Robert J; Ivanov, Alexander R; Skog, Johan; Kuo, Winston Patrick

    2012-01-01

    Extracellular vesicles (ECVs) are nano-sized vesicles released by all cells in vitro as well as in vivo. Their role has been implicated mainly in cell-cell communication, but also in disease biomarkers and more recently in gene delivery. They represent a snapshot of the cell status at the moment of release and carry bioreactive macromolecules such as nucleic acids, proteins, and lipids. A major limitation in this emerging new field is the availability/awareness of techniques to isolate and properly characterize ECVs. The lack of gold standards makes comparing different studies very difficult and may potentially hinder some ECVs-specific evidence. Characterization of ECVs has also recently seen many advances with the use of Nanoparticle Tracking Analysis, flow cytometry, cryo-electron microscopy instruments, and proteomic technologies. In this review, we discuss the latest developments in translational technologies involving characterization methods including the facts in their support and the challenges they face. PMID:22973237

  20. Alternative Methods for Characterization of Extracellular Vesicles

    PubMed Central

    Momen-Heravi, Fatemeh; Balaj, Leonora; Alian, Sara; Tigges, John; Toxavidis, Vasilis; Ericsson, Maria; Distel, Robert J.; Ivanov, Alexander R.; Skog, Johan; Kuo, Winston Patrick

    2012-01-01

    Extracellular vesicles (ECVs) are nano-sized vesicles released by all cells in vitro as well as in vivo. Their role has been implicated mainly in cell–cell communication, but also in disease biomarkers and more recently in gene delivery. They represent a snapshot of the cell status at the moment of release and carry bioreactive macromolecules such as nucleic acids, proteins, and lipids. A major limitation in this emerging new field is the availability/awareness of techniques to isolate and properly characterize ECVs. The lack of gold standards makes comparing different studies very difficult and may potentially hinder some ECVs-specific evidence. Characterization of ECVs has also recently seen many advances with the use of Nanoparticle Tracking Analysis, flow cytometry, cryo-electron microscopy instruments, and proteomic technologies. In this review, we discuss the latest developments in translational technologies involving characterization methods including the facts in their support and the challenges they face. PMID:22973237

  1. An Alternative Method for Multiplication of Rhotrices. Classroom Notes

    ERIC Educational Resources Information Center

    Sani, B.

    2004-01-01

    In this article, an alternative multiplication method for rhotrices is proposed. The method establishes some relationships between rhotrices and matrices. This article has discussed a modified multiplication method for rhotrices. The method has a direct relationship with matrix multiplication, and so rhotrices under this multiplication procedure…

  2. Characterisation of structure-borne sound source using reception plate method.

    PubMed

    Putra, A; Saari, N F; Bakri, H; Ramlan, R; Dan, R M

    2013-01-01

    A laboratory-based experiment procedure of reception plate method for structure-borne sound source characterisation is reported in this paper. The method uses the assumption that the input power from the source installed on the plate is equal to the power dissipated by the plate. In this experiment, rectangular plates having high and low mobility relative to that of the source were used as the reception plates and a small electric fan motor was acting as the structure-borne source. The data representing the source characteristics, namely, the free velocity and the source mobility, were obtained and compared with those from direct measurement. Assumptions and constraints employing this method are discussed. PMID:24324380

  3. Alternative methods of conservative treatment of idiopathic scoliosis.

    PubMed

    Zarzycka, Maja; Rozek, Karina; Zarzycki, Michał

    2009-01-01

    Scoliosis is a deformity of the spine known since Hippocrates times. The value of certain methods of conservative treatment remains controversial. Some of them have only a psychological value both for the physician and his or her caregivers. Based on current literature and the Scoliosis Research Society Report of Alternative Methods of Treatment of Idiopathic Scoliosis, we describe the effectiveness of various alternative methods, such as exercise, Dobosiewicz technique, Karski method, SEAS 02, acupuncture, Alexander technique, aromatherapy, ayurveda, ASCO treatment, biofeedback, chiropractic, Yoga, Feldenkrais method, Pilates method, massage therapy, rolfing, magnet therapy, surface electrical stimulation, PNF, Copes system, and bracing. PMID:19920282

  4. PID techniques: Alternatives to RICH Methods

    SciTech Connect

    Vavra, J.; /SLAC

    2011-03-01

    In this review article we discuss the recent progress in PID techniques other than the RICH methods. In particular we mention the recent progress in the Transition Radiation Detector (TRD), dE/dx cluster counting, and Time Of Flight (TOF) techniques. The TRD technique is mature and has been tried in many hadron colliders. It needs space though, about 20cm of detector radial space for every factor of 10 in the {pi}/e rejection power, and this tends to make such detectors large. Although the cluster counting technique is an old idea, it was never tried in a real physics experiment. Recently, there are efforts to revive it for the SuperB experiment using He-based gases and waveform digitizing electronics. A factor of almost 2 improvement, compared to the classical dE/dx performance, is possible in principle. However, the complexity of the data analysis will be substantial. The TOF technique is well established, but introduction of new fast MCP-PMT and G-APD detectors creates new possibilities. It seems that resolutions below 20-30ps may be possible at some point in the future with relatively small systems, and perhaps this could be pushed down to 10-15ps with very small systems, assuming that one can solve many systematic issues. However, the cost, rate limitation, aging and cross-talk in multi-anode devices at high BW are problems. There are several groups working on these issues, so progress is likely. Table 6 summarizes the author's opinion of pros and cons of various detectors presented in this paper based on their operational capabilities. We refer the reader to Ref.40 for discussion of other more general limits from the PID point of view.

  5. A quantitative method for evaluating alternatives. [aid to decision making

    NASA Technical Reports Server (NTRS)

    Forthofer, M. J.

    1981-01-01

    When faced with choosing between alternatives, people tend to use a number of criteria (often subjective, rather than objective) to decide which is the best alternative for them given their unique situation. The subjectivity inherent in the decision-making process can be reduced by the definition and use of a quantitative method for evaluating alternatives. This type of method can help decision makers achieve degree of uniformity and completeness in the evaluation process, as well as an increased sensitivity to the factors involved. Additional side-effects are better documentation and visibility of the rationale behind the resulting decisions. General guidelines for defining a quantitative method are presented and a particular method (called 'hierarchical weighted average') is defined and applied to the evaluation of design alternatives for a hypothetical computer system capability.

  6. Chemical plating method of preparing radiation source material

    DOEpatents

    Smith, P.K.; Huntoon, R.T.; Mosley, W.C. Jr.

    1973-12-11

    A uniform dispersion of a radioisotope within a noble metal matrix is provided by chemically plating a noble metal coating onto particles including a dissociable compound of the mdioisotope. A suspension of the dissociable compound in a chemically reductive solution is prepared and noble metal cations added to produce the noble metal coatings. The coated particles are filtered, dried and heated to calcine the dissociable compound to a refractory powder. The powder can be encapsulated in measured portions or consolidated and shaped into an elongated form for easy apportionnnent as radiation source material. (Official Gazette)

  7. A Modified Alternating Direction Method for Variational Inequality Problems

    SciTech Connect

    Han, D.

    2002-07-01

    The alternating direction method is an attractive method for solving large-scale variational inequality problems whenever the subproblems can be solved efficiently. However, the subproblems are still variational inequality problems, which are as structurally difficult to solve as the original one. To overcome this disadvantage, in this paper we propose a new alternating direction method for solving a class of nonlinear monotone variational inequality problems. In each iteration the method just makes an orthogonal projection to a simple set and some function evaluations. We report some preliminary computational results to illustrate the efficiency of the method.

  8. Screening for antimicrobial resistance in fecal samples by the replica plating method.

    PubMed Central

    Osterblad, M; Leistevuo, T; Huovinen, P

    1995-01-01

    Replica plating can be used for the detection of antibiotic resistance in normal flora. We have evaluated this application of the replica plating method by comparing it with a five-colony method. The replica plating method uses a single plate for each antibiotic, with a concentration just above that for borderline resistance. By the five-colony method, five colonies per sample were picked, chosen to represent all different colony morphologies present, and MICs were determined by a standard agar dilution method. The gram-negative, aerobic floras of 131 fecal samples were screened for resistance to ampicillin, cefuroxime, nalidixic acid, trimethoprim, sulfamethoxazole, and tetracycline by both methods. The rate of resistance detection by the two methods did not differ statistically for any of the antibiotics tested. The breakpoint concentrations used for the replica plates in the study gave results similar to those produced by the agar dilution method and the breakpoint values of the National Committee for Clinical Laboratory Standards and can thus be recommended. As the only currently used resistance detection method, replica plating facilitates an exact determination of the percentage of resistant colonies/total number of colonies (between 1 and 100%) in a sample. This revealed an uneven distribution, with only 23% of the samples having resistance frequencies in the range of 10 to 85%; usually, the resistant flora either was a small minority or was very dominant in samples with resistance. This phenomenon was present for all of the antibiotics. PMID:8586690

  9. 77 FR 32038 - Energy Conservation Program: Alternative Efficiency Determination Methods and Alternative Rating...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... the Federal Register on April 18, 2011. 76 FR 21673. The RFI requested suggestions, comments, and... ;dct=FR%252BPR%252BN%252BO%252BSR%252BPS;rpp=25;po=0;D=EER E-2011-BT-TP-0024. Table II.1--Stakeholders... Efficiency Determination Methods and Alternative Rating Methods AGENCY: Office of Energy Efficiency...

  10. The hp-MITC finite element method for the Reissner-Mindlin plate problem

    NASA Astrophysics Data System (ADS)

    Ainsworth, Mark; Pinchedez, Katia

    2002-11-01

    The popular MITC finite elements used for the approximation of the Reissner-Mindlin plate are extended to the case where elements of non-uniform degree p distribution are used on locally refined meshes. Such an extension is of particular interest to the hp-version and hp-adaptive finite element methods. A priori error bounds are provided showing that the method is locking-free. The analysis is based on new approximation theoretic results for non-uniform Brezzi-Douglas-Fortin-Marini spaces, and extends the results obtained in the case of uniform order approximation on globally quasi-uniform meshes presented by Stenberg and Suri (SIAM J. Numer. Anal. 34 (1997) 544). Numerical examples illustrating the theoretical results and comparing the performance with alternative standard Galerkin approaches are presented for two new benchmark problems with known analytic solution, including the case where the shear stress exhibits a boundary layer. The new method is observed to be locking-free and able to provide exponential rates of convergence even in the presence of boundary layers.

  11. Low-complexity computation of plate eigenmodes with Vekua approximations and the method of particular solutions

    NASA Astrophysics Data System (ADS)

    Chardon, Gilles; Daudet, Laurent

    2013-11-01

    This paper extends the method of particular solutions (MPS) to the computation of eigenfrequencies and eigenmodes of thin plates, in the framework of the Kirchhoff-Love plate theory. Specific approximation schemes are developed, with plane waves (MPS-PW) or Fourier-Bessel functions (MPS-FB). This framework also requires a suitable formulation of the boundary conditions. Numerical tests, on two plates with various boundary conditions, demonstrate that the proposed approach provides competitive results with standard numerical schemes such as the finite element method, at reduced complexity, and with large flexibility in the implementation choices.

  12. An F1 Schmidt satellite camera and the methods of plate measurement and reduction

    NASA Technical Reports Server (NTRS)

    Hewitt, J.

    1971-01-01

    The f1 Hewitt camera is a field flattened Schmidt system of 60cm aperture. The salient features of this equipment are briefly described. Details of the methods of plate measurement are then given. The plate reduction is carried out in two stages. The plate is first calibrated using the photogrammetric method. The formulae usually quoted have been extended to take account of the large distortion introduced by the field flattening lens. In the second stage, the satellite measurements are reduced to satellite positions corrected for refraction, aberration, and when necessary, phase.

  13. Isolation Method (direct plating or enrichment) does not affect Antimicrobial Susceptibility of Campylobacter from Chicken Carcasses

    Technology Transfer Automated Retrieval System (TEKTRAN)

    To determine if Campylobacter isolation method influenced antimicrobial susceptibility results, the minimum inhibitory concentrations (MIC) of nine antimicrobials were compared for 291 pairs of Campylobacter isolates recovered from chicken carcass rinse samples using direct plating and an enrichment...

  14. Theoretical-experimental method of determining the drag coefficient of a harmonically oscillating thin plate

    NASA Astrophysics Data System (ADS)

    Egorov, A. G.; Kamalutdinov, A. M.; Paimushin, V. N.; Firsov, V. A.

    2016-03-01

    A method for determining the drag coefficient of a thin plate harmonically oscillating in a viscous incompressible fluid is proposed. The method is based on measuring the amplitude of deflections of cantilever-fixed thin plates exhibiting damping flexural oscillations with a frequency corresponding to the first mode and on solving an inverse problem of calculating the drag coefficient on the basis of the experimentally found logarithmic decrement of beam oscillations.

  15. Orbiter Cold Plate Intergranular Corrosion: Development of NDE Standards and Assessment of NDE Methods

    NASA Technical Reports Server (NTRS)

    Smith, Stephen W.; Winfree, William P.; Piascik, Robert S.

    2002-01-01

    During pre-servicing of a space shuttle (orbiter vehicle, OV-102), helium leak detection of an avionics cold plate identified a leak located in the face sheet oriented towards the support shelf. Subsequent destructive examination of the leaking cold plate revealed that intergranular corrosion had penetrated the 0.017-inch thick aluminum (AA6061) face sheet. The intergranular attack (IGA) was likely caused by an aggressive crevice environment created by condensation of water vapor between the cold plate and support shelf. Face sheet susceptibility to IGA is a result of the brazing process used in the fabrication of the cold plates. Cold plate components were brazed at 1000 F followed by a slow cooling process to avoid distortion of the bonded cold plate. The slow cool process caused excessive grain boundary precipitation resulting in a material that is susceptible to IGA. The objectives of this work are as follows: (1) Develop first-of-a-kind nondestructive evaluation (NDE) standards that contain IGA identical to that found in the orbiter cold plates; and (2) Assess advanced NDE techniques for corrosion detection and recommend methods for cold plate examination. This report documents the results of work performed at Langley Research Center to fulfill these objectives.

  16. Irradiated homologous tarsal plate banking: A new alternative in eyelid reconstruction. Part I. Technique and animal research

    SciTech Connect

    Jordan, D.R.; Tse, D.T.; Anderson, R.L.; Hansen, S.O. )

    1990-01-01

    Reconstruction of full thickness eyelid defects requires the correction of both posterior lamella (tarsus, conjunctiva) and anterior lamella (skin, muscle). Tarsal substitutes including banked sclera, nasal cartilage, ear cartilage, and periosteum can be beneficial for posterior lamellar repair, while anterior lamellar replacement, including skin grafts, pedicle flaps, advancement flaps, etc., is important to cover the posterior reconstructed portion. At times, due to extensive tissue loss, the eyelid reconstruction can be particularly challenging. We have found an alternative posterior lamellar reconstructive technique utilizing irradiated homologous tarsal plate that can be particularly useful in selected cases of severe tissue loss. The experimental surgical procedure in monkeys and the histological fate of the implanted tarsus is described in Part I, and followed in Part II by our experience with this tissue in six human patients.

  17. Validation of an alternative microbiological method for tissue products.

    PubMed

    Suessner, Susanne; Hennerbichler, Simone; Schreiberhuber, Stefanie; Stuebl, Doris; Gabriel, Christian

    2014-06-01

    According to the European Pharmacopoeia sterility testing of products includes an incubation time of 14 days in thioglycollate medium and soya-bean casein medium. In this case a large period of time is needed for product testing. So we designed a study to evaluate an alternative method for sterility testing. The aim of this study was to reduce the incubation time for the routinely produced products in our tissue bank (cornea and amnion grafts) by obtaining the same detection limit, accurateness and recovery rates as the reference method described in the European Pharmacopoeia. The study included two steps of validation. Primary validation compared the reference method with the alternative method. Therefore eight bacterial and two fungi test strains were tested at their preferred milieu. A geometric dilution series from 10 to 0.625 colony forming unit per 10 ml culture media was used. Subsequent to the evaluation the second part of the study started including the validation of the fertility of the culture media and the parallel testing of the two methods by investigating products. For this purpose two product batches were tested in three independent runs. Concerning the validation we could not find any aberration between the alternative and the reference method. In addition, the recovery rate of each microorganism was between 83.33 and 100 %. The alternative method showed non-inferiority regarding accuracy to the reference method. Due to this study we reduced the sterility testing for cornea and amniotic grafts to 9 days. PMID:24810914

  18. 49 CFR 218.29 - Alternate methods of protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Blue Signal Protection of Workers § 218.29 Alternate methods of protection. Instead of providing blue signal protection for workers in accordance with § 218.27, the following methods for blue signal protection may be used: (a) When workers...

  19. Overview On Alternative Asbestos Control Method Research - St. Louis, MO

    EPA Science Inventory

    The alternative asbestos control method (AACM) is an experimental approach to building demolition. Unlike the NESHAP method, the AACM allows some regulated asbestos-containing material to remain in the building and a surfactant-water solution is used to suppress asbestos fibers ...

  20. Overview On Alternative Asbestos Control Method Research - Wisconsin Dells

    EPA Science Inventory

    The alternative asbestos control method (AACM) is an experimental approach to building demolition. Unlike the NESHAP method, the AACM allows some regulated asbestos containing material to remain in the building and a surfactant-water solution is used to suppress asbestos fibers ...

  1. Overview On Alternative Asbestos Control Method Research - Nashville, TN

    EPA Science Inventory

    The alternative asbestos control method (AACM) is an experimental approach to building demolition. Unlike the NESHAP method, the AACM allows some regulated asbestos-containing material to remain in the building and a surfactant-water solution is used to suppress asbestos fibers ...

  2. 27 CFR 24.22 - Alternate method or procedure.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate method or procedure. 24.22 Section 24.22 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... purpose of, and consistent with the effect intended by, the specifically prescribed method or...

  3. Method and apparatus for actively controlling a micro-scale flexural plate wave device

    DOEpatents

    Dohner, Jeffrey L.

    2001-01-01

    An actively controlled flexural plate wave device provides a micro-scale pump. A method of actively controlling a flexural plate wave device produces traveling waves in the device by coordinating the interaction of a magnetic field with actively controlled currents. An actively-controlled flexural plate wave device can be placed in a fluid channel and adapted for use as a micro-scale fluid pump to cool or drive micro-scale systems, for example, micro-chips, micro-electrical-mechanical devices, micro-fluid circuits, or micro-scale chemical analysis devices.

  4. Quantitative thin layer chromatography for the analysis of skin surface lipids. A time-saving method using a new TLC plate.

    PubMed

    Weissmann, A

    1979-07-30

    Recently a new thin layer chromatography plate (Whatman LK 6D) became available which is extremely easy to handle and permits highly reproducible qualitative and quantitative analysis. This plate proved to be of great value for the investigation of skin surface lipids. The use of a fatty acid methyl ester as an internal standard makes it unnecessary to employ additional gravimetrical or photometrical methods for quanitative lipid analysis. The method presented in this paper is simpler and requires much less time than alternative procedures and allows a large number of lipid samples to be processed simultaneously. PMID:475450

  5. Alternating method applied to edge and surface crack problems.

    NASA Technical Reports Server (NTRS)

    Hartranft, R. J.; Sih, G. C.

    1973-01-01

    The alternating method, which intimately combines analytical results with numerical calculations, as applied to edge crack problems in two dimensions and surface crack problems in three dimensions, is treated. The case of a crack perpendicular to the edge of a semiinfinite material is considered. One of the crack geometries that has received continual interest in fracture mechanics is that of a semielliptical crack whose major axis lies on a stress free surface. In order to demonstrate the sensitivity of the solution to the influence of the free surface the semicircular crack problem is again treated by the alternating method.

  6. Experimental method for laser-driven flyer plates for 1-D shocks

    SciTech Connect

    Paisley, D. L.; Luo, S. N.; Swift, D. C.; Loomis, E.; Johnson, R.; Greenfield, S.; Peralta, P.; Koskelo, A.; Tonks, D.

    2007-12-12

    One-dimensional shocks can be generated by impacting flyer plates accelerated to terminal velocities by a confined laser-ablated plasma. Over the past few years, we have developed this capability with our facility-size laser, TRIDENT, capable of {>=}500 Joules at multi-microsecond pulse lengths to accelerate 1-D flyer plates, 8-mm diameter by 0.1-2 mm thick. Plates have been accelerated to terminal velocities of 100 to {>=}500 m/s, with full recovery of the flyer and target for post mortem metallography. By properly tailoring the laser temporal and spatial profile, the expanding confined plasma accelerates the plate away from the transparent sapphire substrate, and decouples the laser parameters from shock pressure profile resulting from the plate impact on a target. Since the flyer plate is in free flight on impact with the target, minimal collateral damage occurs to either. The experimental method to launch these plates to terminal velocity, ancillary diagnostics, and representative experimental data is presented.

  7. An Alternative Surgical Method for Treatment of Osteoid Osteoma

    PubMed Central

    Gökalp, Mehmet Ata; Gözen, Abdurrahim; Ünsal, Seyyid Şerif; Önder, Haci; Güner, Savaş

    2016-01-01

    Background An osteoid osteoma is a benign bone tumor that tends to be <1 cm in size. The tumor is characterized by night-time pain that may be relieved by aspirin or other non-steroidal anti-inflammatory drugs. Osteoid osteoma can be treated with various conservative and surgical methods, but these have some risks and difficulties. The purpose of the present study was to present an alternative treatment method for osteoid osteoma and the results we obtained. Material/Methods In the period from 2010 to 2014, 10 patients with osteoid osteoma underwent nidus excision by using a safe alternative method in an operating room (OR) with no computed tomography (CT). The localization of the tumor was determined by use of a CT-guided Kirschner wire in the radiology unit, then, in the OR the surgical intervention was performed without removing the Kirschner wire. Results Following the alternative intervention, all the patients were completely relieved of pain. In the follow-up, no recurrence or complication occurred. Conclusions The presented alternative method for treating osteoid osteoma is an efficient and practical procedure for surgeons working in clinics that lack specialized equipment. PMID:26898923

  8. Prediction of skin sensitizers using alternative methods to animal experimentation.

    PubMed

    Johansson, Henrik; Lindstedt, Malin

    2014-07-01

    Regulatory frameworks within the European Union demand that chemical substances are investigated for their ability to induce sensitization, an adverse health effect caused by the human immune system in response to chemical exposure. A recent ban on the use of animal tests within the cosmetics industry has led to an urgent need for alternative animal-free test methods that can be used for assessment of chemical sensitizers. To date, no such alternative assay has yet completed formal validation. However, a number of assays are in development and the understanding of the biological mechanisms of chemical sensitization has greatly increased during the last decade. In this MiniReview, we aim to summarize and give our view on the recent progress of method development for alternative assessment of chemical sensitizers. We propose that integrated testing strategies should comprise complementary assays, providing measurements of a wide range of mechanistic events, to perform well-educated risk assessments based on weight of evidence. PMID:24548737

  9. Alternative method of retesting UF{sub 6} cylinders

    SciTech Connect

    Christ, R.

    1991-12-31

    The paper describes an alternative method to perform the periodic inspection of UF{sub 6} cylinders. The hydraulic test is replaced by ultrasonic checking of wall thickness and by magnetic particle testing of all the weld seams. Information about the legal background, the air leak test and the qualification of inspectors is also given.

  10. 27 CFR 41.26 - Alternate methods or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Alternate methods or procedures. 41.26 Section 41.26 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO IMPORTATION OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO General §...

  11. 27 CFR 40.45 - Alternate methods or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Alternate methods or procedures. 40.45 Section 40.45 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED...

  12. 27 CFR 40.385 - Alternate methods or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Alternate methods or procedures. 40.385 Section 40.385 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED...

  13. 27 CFR 17.3 - Alternate methods or procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Alternate methods or procedures. 17.3 Section 17.3 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DRAWBACK ON TAXPAID DISTILLED SPIRITS USED IN MANUFACTURING NONBEVERAGE PRODUCTS General Provisions §...

  14. 27 CFR 18.13 - Alternate methods or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures. 18.13 Section 18.13 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE...

  15. 27 CFR 18.13 - Alternate methods or procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Alternate methods or procedures. 18.13 Section 18.13 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE...

  16. 27 CFR 26.331 - Alternate methods or procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Alternate methods or procedures. 26.331 Section 26.331 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Miscellaneous Provisions § 26.331...

  17. 27 CFR 19.665 - Alternate methods or procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or procedures. 19.665 Section 19.665 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL DISTILLED SPIRITS PLANTS Distilled Spirits for Fuel...

  18. 27 CFR 19.903 - Alternate methods or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures. 19.903 Section 19.903 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Distilled Spirits For Fuel Use §...

  19. Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K. (Inventor); Braff, William A. (Inventor)

    2013-01-01

    An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

  20. Approximate natural vibration analysis of rectangular plates with openings using assumed mode method

    NASA Astrophysics Data System (ADS)

    Cho, Dae Seung; Vladimir, Nikola; Choi, Tae MuK

    2013-09-01

    Natural vibration analysis of plates with openings of different shape represents an important issue in naval architecture and ocean engineering applications. In this paper, a procedure for vibration analysis of plates with openings and arbitrary edge constraints is presented. It is based on the assumed mode method, where natural frequencies and modes are determined by solving an eigenvalue problem of a multi-degree-of-freedom system matrix equation derived by using Lagrange's equations of motion. The presented solution represents an extension of a procedure for natural vibration analysis of rectangular plates without openings, which has been recently presented in the literature. The effect of an opening is taken into account in an intuitive way, i.e. by subtracting its energy from the total plate energy without opening. Illustrative numerical examples include dynamic analysis of rectangular plates with rectangular, elliptic, circular as well as oval openings with various plate thicknesses and different combinations of boundary conditions. The results are compared with those obtained by the finite element method (FEM) as well as those available in the relevant literature, and very good agreement is achieved.

  1. Development of target allocation methods for LAMOST focal plate

    NASA Astrophysics Data System (ADS)

    Yuan, Hailong; Zhang, Haotong; Zhang, Yanxia; Lei, Yajuan; Dong, Yiqiao

    2014-01-01

    We first introduce the primary target allocation requirements and restrictions for the parallel control multiple fiber system, which is used in the LAMOST spectroscopic survey. The fiber positioner anti-collision model is imported. Then several target allocation methods and features are discussed in detail, including a network flow algorithm, high priority for fiber unit holding less target number, target allocation algorithm for groups, target allocation method for add-ons and target reallocation. Their virtues and weaknesses are analyzed for various kinds of scientific research situations. Furthermore an optimization concept using the Simulate Anneal Arithmetic (SAA) is developed to improve the fiber utilizing efficiency.

  2. Practical method of diffusion-welding steel plate in air

    NASA Technical Reports Server (NTRS)

    Holko, K. H.; Moore, T. J.

    1971-01-01

    Method is ideal for critical service requirements where parent metal properties are equaled in notch toughness, stress rupture and other characteristics. Welding technique variations may be used on a variety of materials, such as carbon steels, alloy steels, stainless steels, ceramics, and reactive and refractory materials.

  3. Numerical design method for thermally loaded plate-cylinder intersections

    SciTech Connect

    Baldur, R.; Laberge, C.A.; Lapointe, D. )

    1988-11-01

    This paper is an extension of work on stresses in corner radii described by the authors previously. Whereas the original study concerned itself with pressure effects only and the second reference gave the initial version of the work dealing with the thermal effects, this report gives more recent results concerning specifically thermal loads. As before, the results are limited to inside corner radii between cylinders and flat heat closures. Similarly, the analysis is based on a systematic series of finite element calculations with the significant parameters covering the field of useful design boundaries. The results are condensed into a rapid method for the determination of peak stresses needed for performing fatigue analysis in pressure vessels subjected to a significant, variable thermal load. The paper takes into account the influence of the film coefficient, temporal temperature variations, and material properties. A set of coefficients provides a convenient method of stress evaluation suitable for design purposes.

  4. Method of forming aperture plate for electron microscope

    NASA Technical Reports Server (NTRS)

    Heinemann, K. (Inventor)

    1974-01-01

    An electron microscope is described with an electron source a condenser lens having either a circular aperture for focusing a solid cone of electrons onto a specimen or an annular aperture for focusing a hollow cone of electrons onto the specimen. It also has objective lens with an annular objective aperture, for focusing electrons passing through the specimen onto an image plane. A method of making the annular objective aperture using electron imaging, electrolytic deposition and ion etching techniques is included.

  5. An approximate method for sonic fatigue analysis of plates and shells

    NASA Astrophysics Data System (ADS)

    Blevins, R. D.

    1989-02-01

    Approximate analytical methods are developed for determining the response of plate and shell structures to coherent sound fields. The methods are based on separating the spatial and temporal aspects of the problem and then developing approximations for both. Direct comparison is made with experimental data.

  6. Phase Velocity Method for Guided Wave Measurements in Composite Plates

    NASA Astrophysics Data System (ADS)

    Moreno, E.; Galarza, N.; Rubio, B.; Otero, J. A.

    Carbon Fiber Reinforced Polymer is a well-recognized material for aeronautic applications. Its plane structure has been widely used where anisotropic characteristics should be evaluated with flaw detection. A phase velocity method of ultrasonic guided waves based on a pitch-catch configuration is presented for this purpose. Both shear vertical (SV) and shear horizontal (SH) have been studied. For SV (Lamb waves) the measurements were done at different frequencies in order to evaluate the geometrical dispersion and elastic constants. The results for SV are discussed with an orthotropic elastic model. Finally experiments with lamination flaws are presented.

  7. Free vascularized fibular grafts for femoral head osteonecrosis: alternative technique utilizing a buttress plate for graft fixation.

    PubMed

    Woodhouse, Andrew G; Drake, Matthew L; Lee, Gwo Chin; Levin, L Scott; Tintle, Scott M

    2015-01-01

    Core decompression with free vascularized fibular grafting is an effective hip preservation treatment for osteonecrosis of the femoral head. This procedure has traditionally utilized a single Kirschner wire to secure the fibular strut within the femoral neck. While this method has proven effective, migration of the Kirschner wire remains the most common recipient site complication. Additionally the presence of the Kirschner wire traversing the intramedullary canal can also complicate future hip arthroplasty. Therefore, this article describes a simple graft fixation technique utilizing a buttress plate that obviates migration problems. Ten patients are presented with at least 6 months of follow-up who have been treated with this technique without complications. This fixation method is simple and eliminates a major potential complication and allows for easier conversion to total hip arthroplasty. PMID:25988699

  8. 3-D vibration analysis of annular sector plates using the Chebyshev-Ritz method

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Lo, S. H.; Cheung, Y. K.

    2009-02-01

    The three-dimensional free vibration of annular sector plates with various boundary conditions is studied by means of the Chebyshev-Ritz method. The analysis is based on the three-dimensional small strain linear elasticity theory. The product of Chebyshev polynomials satisfying the necessary boundary conditions is selected as admissible functions in such a way that the governing eigenvalue equation can be conveniently derived through an optimization process by the Ritz method. The boundary functions guarantee the satisfaction of the geometric boundary conditions of the plates and the Chebyshev polynomials provide the robustness for numerical calculation. The present study provides a full vibration spectrum for the thick annular sector plates, which cannot be given by the two-dimensional (2-D) theories such as the Mindlin theory. Comprehensive numerical results with high accuracy are systematically produced, which can be used as benchmark to evaluate other numerical methods. The effect of radius ratio, thickness ratio and sector angle on natural frequencies of the plates with a sector angle from 120° to 360° is discussed in detail. The three-dimensional vibration solutions for plates with a re-entrant sector angle (larger than 180°) and shallow helicoidal shells (sector angle larger than 360°) with a small helix angle are presented for the first time.

  9. An analytical method of free vibration for laminated plates including various boundary conditions

    NASA Astrophysics Data System (ADS)

    Xia, Chuanyou; Wen, Lizhou

    1991-10-01

    It is shown that, by introducing the displacement function Phi(x, y, t), the system of original differential equations developed by Whitney and Pagano (1970) for the first-order shear deformation theory of symmetric cross-ply laminated plates can be transformed into a single differential equation of the displacement function. On the basis of this differential equation an exact solution is given to the problem of free vibration of symmetric cross-ply laminated plates including various boundary conditions. It is shown that the natural frequencies obtained by the present analytical method are lower than those of results obtained using approximate methods.

  10. Alternative to the Palatini method: A new variational principle

    SciTech Connect

    Goenner, Hubert

    2010-06-15

    A variational principle is suggested within Riemannian geometry, in which an auxiliary metric and the Levi Civita connection are varied independently. The auxiliary metric plays the role of a Lagrange multiplier and introduces nonminimal coupling of matter to the curvature scalar. The field equations are 2nd order PDEs and easier to handle than those following from the so-called Palatini method. Moreover, in contrast to the latter method, no gradients of the matter variables appear. In cosmological modeling, the physics resulting from the alternative variational principle will differ from the modeling using the standard Palatini method.

  11. An extended field method solution for a pulse loaded thin plate

    NASA Technical Reports Server (NTRS)

    Donaldson, B. K.; Starkey, N. B.

    1980-01-01

    This paper deals with a new extension of a weighted residual method of analysis called the extended field method. The extended field method is applied for the first time to the problem of the transient vibration of a uniformly thin elastic plate. Numerical results have been obtained which validate the analysis procedure and show better solution convergence than is obtainable by standard methods of analysis for the same number of degrees of freedom. Further studies are necessary to obtain still better convergence.

  12. An alternate method to springback compensation for sheet metal forming.

    PubMed

    Siswanto, Waluyo Adi; Anggono, Agus Dwi; Omar, Badrul; Jusoff, Kamaruzaman

    2014-01-01

    The aim of this work is to improve the accuracy of cold stamping product by accommodating springback. This is a numerical approach to improve the accuracy of springback analysis and die compensation process combining the displacement adjustment (DA) method and the spring forward (SF) algorithm. This alternate hybrid method (HM) is conducted by firstly employing DA method followed by the SF method instead of either DA or SF method individually. The springback shape and the target part are used to optimize the die surfaces compensating springback. The hybrid method (HM) algorithm has been coded in Fortran and tested in two- and three-dimensional models. By implementing the HM, the springback error can be decreased and the dimensional deviation falls in the predefined tolerance range. PMID:25165738

  13. An Alternate Method to Springback Compensation for Sheet Metal Forming

    PubMed Central

    Omar, Badrul; Jusoff, Kamaruzaman

    2014-01-01

    The aim of this work is to improve the accuracy of cold stamping product by accommodating springback. This is a numerical approach to improve the accuracy of springback analysis and die compensation process combining the displacement adjustment (DA) method and the spring forward (SF) algorithm. This alternate hybrid method (HM) is conducted by firstly employing DA method followed by the SF method instead of either DA or SF method individually. The springback shape and the target part are used to optimize the die surfaces compensating springback. The hybrid method (HM) algorithm has been coded in Fortran and tested in two- and three-dimensional models. By implementing the HM, the springback error can be decreased and the dimensional deviation falls in the predefined tolerance range. PMID:25165738

  14. Alternative Processing Methods for Ultra High Temperature Ceramics

    NASA Technical Reports Server (NTRS)

    Gusman, Michael; Beckman, Sarah; Gasch, Matthew; Ellerby, Don; Lau, Kai-Hung; Sanjurjo, Angel; Johnson, Sylvia M.; Venkatapathy, Ethiras (Technical Monitor)

    2002-01-01

    Ultra High Temperature Ceramics (UHTCs) are being developed for possible use in a number of structural applications including hypersonic vehicles, engines, plasma arc electrodes and high temperature shielding. Alternative methods of processing Ultra High Temperature Ceramics (UHTCs) will be discussed. Techniques that may improve oxidation resistance, strength, and reduce the processing temperature of the UHTCs will be presented. Hot-pressed UHTCs made using either milled/uncoated powders or non-milled coated powders will be compared.

  15. Schwarz alternating methods for anisotropic problems with prolate spheroid boundaries.

    PubMed

    Dai, Zhenlong; Du, Qikui; Liu, Baoqing

    2016-01-01

    The Schwarz alternating algorithm, which is based on natural boundary element method, is constructed for solving the exterior anisotropic problem in the three-dimension domain. The anisotropic problem is transformed into harmonic problem by using the coordinate transformation. Correspondingly, the algorithm is also changed. Continually, we analysis the convergence and the error estimate of the algorithm. Meanwhile, we give the contraction factor for the convergence. Finally, some numerical examples are computed to show the efficiency of this algorithm. PMID:27625977

  16. An alternative method for cultivation of Lawsonia intracellularis.

    PubMed

    Vannucci, Fabio A; Wattanaphansak, Suphot; Gebhart, Connie J

    2012-03-01

    An alternative method for the cultivation of Lawsonia intracellularis, an obligate intracellular bacterium and the causative agent of proliferative enteropathy, was developed using an Original Space Bag inflated with a mixture of gas containing 10% hydrogen, 10% carbon dioxide, and 80% nitrogen. The flexibility of this protocol allows the testing of various environmental conditions for static cultivation of this bacterium and the development of diagnostic techniques. PMID:22219308

  17. A variable-order laminated plate theory based on the variational-asymptotical method

    NASA Technical Reports Server (NTRS)

    Lee, Bok W.; Sutyrin, Vladislav G.; Hodges, Dewey H.

    1993-01-01

    The variational-asymptotical method is a mathematical technique by which the three-dimensional analysis of laminated plate deformation can be split into a linear, one-dimensional, through-the-thickness analysis and a nonlinear, two-dimensional, plate analysis. The elastic constants used in the plate analysis are obtained from the through-the-thickness analysis, along with approximate, closed-form three-dimensional distributions of displacement, strain, and stress. In this paper, a theory based on this technique is developed which is capable of approximating three-dimensional elasticity to any accuracy desired. The asymptotical method allows for the approximation of the through-the-thickness behavior in terms of the eigenfunctions of a certain Sturm-Liouville problem associated with the thickness coordinate. These eigenfunctions contain all the necessary information about the nonhomogeneities along the thickness coordinate of the plate and thus possess the appropriate discontinuities in the derivatives of displacement. The theory is presented in this paper along with numerical results for the eigenfunctions of various laminated plates.

  18. SLCA/IP power alternative screening method (SPASM)

    SciTech Connect

    Palmer, S.C. |; Ancrile, J.D.

    1995-03-01

    This report describes the SLCA/IP Power Alternative Screening Method (SPASM), which was used to screen 784 possible combinations of electric power marketing alternatives and dam operational scenarios to provide a representative range for analysis in the Western Area Power Administration Salt Lake City Area Integrated Projects (SLCA/IP) Electric Power Marketing Environmental Impact Statement (EIS). Each combination consists of one energy and capacity commitment level and one operational scenario for each of the hydroelectric facilities at Glen Canyon Dam, Flaming Gorge Dam, and the Aspinall Unit. The total annual cost to the SLCA/IP firm power customers of each of the 784 combinations is estimated and included in a relative frequency distribution. A relative frequency distribution is also generated for each marketing alternative. The number of combinations is reduced to 12 by taking the mean value and endpoint value for each of four marketing alternatives. Some minor deviations from this procedure, which are made for political purposes, are explained. 9 figs., 14 tabs.

  19. Validating the plate mapping method: Comparing drawn foods and actual foods of university students in a cafeteria.

    PubMed

    Sharp, David E

    2016-05-01

    To examine effects of plate size on meals, I developed a method I label plate mapping. To validate plate mapping, a quasi-experimental between participants study was conducted that asked university students to accurately draw their lunch meal. Participants were randomized into groups where they were asked either pre-consumption or post-consumption to draw their lunch on either a 9″ or 11″ paper plate. Coding plate drawings for total meal size revealed that students drew bigger meals on larger plates and participant meal size drawings were more accurate when the plate provided was the same size as the meal plate used. Gender moderated meal size drawings, with women generally drawing meals that were more highly correlated and similarly sized to actual meals when compared to the drawings of men. Overall, the size of plate drawings was highly correlated with the size of actual foods, which provides support for the validity of the method of plate mapping. These findings suggest that plate mapping can be applied to estimate meal size and assess sensitivity to plate size. Gaining a better understanding of the mechanisms and processes that influence food consumption habits can help increase awareness of these cues for both academics as well as for consumers of food and benefit short- and long-term health goals. PMID:26896836

  20. IDENTIFICATION OF SALMONELLA-POSITIVE FECAL SAMPLES USING A 96-WELL MICROCULTURE PLATE TECHNIQUE (RX METHOD)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional Salmonella isolation involves multiple sample transfers to culture media performed by an experienced microbiologist. The modified semi-solid RV and XLT (RX) Plate method, a modification of the RX tube format designed by Gailey et al. (2004), consolidates pre-enrichment (buffered pepton...

  1. Enumeration of Salmonella from Poultry Carcass Rinses via Direct Plating Methods

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Direct plating methods for the estimation of Salmonella load in poultry carcass rinses were evaluated. Twenty broiler carcasses were collected weekly for three weeks from each of three sites (pre-inside outside bird wash [Pre-IOBW], Pre-chill and Post-chill) in a poultry abattoir resulting in 60 ca...

  2. Voltage oxide removal for plating: A new method of electroplating oxide coated metals in situ

    SciTech Connect

    Gutfeld, R. J. von; West, A. C.

    2007-03-15

    A novel in situ method for electroplating oxide coated metals is described. Termed VORP, for voltage oxide removal for plating, the process utilizes a voltage pulse {approx}20-200 V, {approx}2 ms in duration, applied between working and counterelectrodes while both are immersed in a copper electrolyte. The pulse is almost immediately followed by galvanostatic plate-up. Adherent copper deposits up to {approx}4 {mu}m in height on stainless steel 316 coupons have been obtained. Temperature testing up to 260 deg. C in air does not affect the copper adhesion. A preliminary model for oxide removal is proposed utilizing concepts of dielectric breakdown.

  3. Method for preparing surfaces of metal composites having a brittle phase for plating. [Patent application

    DOEpatents

    Coates, C.W.; Wilson, T.J.

    1982-05-19

    The present invention is directed to a method for preparing surfaces of two-phase metal composites having relatively brittle and malleable components for plating with corrosion-resistant material. In practice of the present invention, the surfaces of the composite are etched to remove a major portion or fraction of the brittle component. The etched surface is then peened with particulates for breaking the brittle component from the surfaces and for spreading or smearing the malleable component over the surfaces. The peened surface is then chemically cleaned of residual traces of the brittle component to which the corrosion-resistant material may be plated thereon in an adherent manner.

  4. Measurement of transitional boundary layer on a flat plate using a computational Preston tube method

    NASA Astrophysics Data System (ADS)

    Jeon, W. P.; Kang, S. H.

    1995-11-01

    The development of the transitional boundary layers on a flat plate in uniform and non-uniform incoming flows was experimentally investigated. The mean velocity profiles and the wall shear stresses on a flat plate were measured in the wakes which were generated by circular cylinders and a flat plate ahead of the test plate. A computational Preston tube method (CPM) originally proposed by Nitsche et al. (1983) was adopted and refined to measure the skin friction coefficients in the transitional boundary layer. The CPM was verified as a useful tool to measure the skin-friction over the transitional boundary layer with reasonable accuracy. As the turbulence level in the wakes increased, the starting and ending points of the transition moved progressively upstream. For the same turbulence intensities, the transition was delayed with increase of the length scale. The skin-friction coefficients at the downstream stations in the wake flow were considerably and consistently smaller than the values in the equilibrium turbulent boundary layer of the uniform flow. The transition length for the cases of the plate-wake were shorter than those for the cases of the cylinder-wake as well as the uniform flow.

  5. Increasing photoactivity of titanium dioxide immobilized on glass plate with optimization of heat attachment method parameters.

    PubMed

    Behnajady, Mohammad A; Modirshahla, Nasser; Mirzamohammady, Maryam; Vahid, Behrouz; Behnajady, Bahram

    2008-12-30

    In the present work the optimization of heat attachment method for increasing photoactivity of immobilized TiO2 on glass plate was investigated. Results show that sonication time, TiO2 suspension dosage, immobilization temperature, solvent type and immobilization replications are very effective on the photoactivity of immobilized TiO2 on glass plate on the removal of C.I. Acid Red 88 (AR88) and optimizing these parameters increases the photoactivity of immobilized catalyst. In other step, the effect of operational parameters such as light intensity and initial concentration of AR88 on the removal of AR88 was investigated with four times immobilized TiO2 on glass plate. Results show that removal rate decreases with increasing initial concentration of AR88 but increases with increasing UV-light intensity. PMID:18440135

  6. Second-order two-scale method for bending behaviors of composite plate with periodic configuration

    NASA Astrophysics Data System (ADS)

    Zhu, Guoqing; Cui, Junzhi

    2010-06-01

    In this paper, the second-order two-scale analysis method for bending behaviors of the plate made from composites with 3-D periodic configuration is presented by means of construction way. It can capture the microscopic 3-D mechanics behaviors caused from 3-D micro-structures. First, directly starting from the 3-D elastic plate model of composite materials with 3-D periodic configuration, three cell models are defined, and correspondingly the three classes of cell functions only defined on 3 normalized cells are constructed. And then, the effective homogenization parameters of composites are calculated from those local functions, it leads to a 2-D homogenized laminar plate problem. Next, to solve it the homogenization solution is obtained. Finally, the second-order two-scale solution is constructed from the micro-cell functions and the homogenization solution.

  7. Second-Order Two-Scale Method for Bending Behaviors of Composite Plate with Periodic Configuration

    NASA Astrophysics Data System (ADS)

    Zhu, Guoqing; Cui, Junzhi

    2010-05-01

    In this paper, the second-order two-scale analysis method for bending behaviors of the plate made from composites with 3-D periodic configuration is presented by means of construction way. It can capture the microscopic 3-D mechanics behaviors caused from 3-D micro-structures. First, directly starting from the 3-D elastic plate model of composite materials with 3-D periodic configuration, three cell models are defined, and correspondingly the three classes of cell functions only defined on 3 normalized cells are constructed. And then, the effective homogenization parameters of composites are calculated from those local functions, it leads to a 2-D homogenized laminar plate problem. Next, to solve it the homogenization solution is obtained. Finally, the second-order two-scale solution is constructed from the micro-cell functions and the homogenization solution.

  8. Characterization of nano-sized SiC@Ni composite fabricated by electroless plating method.

    PubMed

    Xu, Zhan; Chen, Yigang

    2013-02-01

    A nano-sized SiC@Ni composite was prepared by simple electroless plating method. Nickel can be reduced by Na2H2PO2 under the catalysis of Pd to despite onto the surface of SiC nanoparticles. The composite structure was characterized by means of TEM images, XRD and the components were analyzed using EDS. The coating layer on the SiC particles was several nanometers thick and mainly in a form of fine Ni crystalline grain and amorphous Ni-P alloy. By increasing the concentration of Na2H2PO2 in the plating bath, the uniformity of the coating layer can be improved obviously. Both of the magnetism and crystallinity of Ni coatings depends on the P content in the coating which can be decreased by increasing the pH values of plating solutions. The SiC@Ni particles exhibited soft magnetic characteristics. PMID:23646660

  9. Identification of spatially correlated excitations on a bending plate using the Virtual Fields Method

    NASA Astrophysics Data System (ADS)

    Berry, Alain; Robin, Olivier

    2016-08-01

    This paper aims at identifying the autospectral density and spatial correlation functions of random excitations acting on the surface of a thin plate, from its measured vibration response. The general framework is the Virtual Fields Method (VFM), which was previously applied by the authors to the identification of deterministic excitations on plates. In the present paper, the VFM framework is extended to the case of spatially correlated excitations. It is shown that extraction of the loading power spectral density requires measuring power spectral density functions of transverse displacements and bending curvatures, which can be typically derived from contactless Laser Doppler Vibrometry measurements. The paper details the implementation of the VFM for random excitations, presents numerical simulations and experimental results for diffuse acoustic field excitation of a plate.

  10. Plate measurement techniques and reduction methods used by the West German satellite observers, and resulting consequences for the observation

    NASA Technical Reports Server (NTRS)

    Deker, H.

    1971-01-01

    The West German tracking stations are equipped with ballistic cameras. Plate measurement and plate reduction must therefore follow photogrammetric methods. Approximately 100 star positions and 200 satellite positions are measured on each plate. The mathematical model for spatial rotation of the bundle of rays is extended by including terms for distortion and internal orientation of the camera as well as by providing terms for refraction which are computed for the measured coordinates of the star positions on the plate. From the measuring accuracy of the plate coordinates it follows that the timing accuracy for the exposures has to be about one millisecond, in order to obtain a homogeneous system.

  11. 48 CFR 32.503-9 - Liquidation rates-alternate method.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-alternate method. 32.503-9 Section 32.503-9 Federal Acquisition Regulations System FEDERAL ACQUISITION... Liquidation rates—alternate method. (a) The liquidation rate determined under 32.503-8 shall apply throughout... the alternate method in this 32.503-9. The objective of the alternate liquidation rate method is...

  12. Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.

    PubMed

    Olsson, O

    2000-10-01

    In allowing compression along the femoral shaft (uniaxial dynamization) and optional compression along the femoral neck (biaxial dynamization), the Medoff sliding plate (MSP) represents a new principle in the fixation of trochanteric hip fractures. The Twin hook with 2 apical hooks was designed as an alternative to the lag screw. In 3 prospective consecutive case series and 1 prospective randomized study together comprising 342 trochanteric fractures, these alternative techniques were investigated. 3 postoperative fixation failures occurred in the unstable intertrochanteric fractures treated with biaxial dynamization with the MSP (n = 194), and 5 in those treated with the sliding hip screw (n = 62) (p = 0.04). A mean femoral shortening of 15 mm with the MSP and 11 mm with the sliding hip screw was found (p = 0.03). More medialization of the femoral shaft occurred with the sliding hip screw (26%) than with the MSP (12%) in patients with marked femoral shortening (p = 0.03). 3 postoperative fixation failures occurred in subtrochanteric fractures treated with uniaxial dynamization (n = 29) and 2 in those treated with biaxial dynamization (n = 19). Medialization of the femoral shaft occurred in 9 of the 19 biaxially dynamized fractures. The Twin hook was used in 50 patients and appeared to provide similar fixation stability as the lag screw. Biomechanical tests confirmed improved stress transmission over the fracture area with the MSP compared to the sliding hip screw in intertrochanteric fractures, and similar fixation stability with the MSP and the Intramedullary Hip Screw in subtrochanteric fractures. In axial and torsional loading, the Twin hook demonstrated gradually increasing resistance to migration. With the lag screw, the peak load was higher, but after migration with failure of the support by the threads, the loads were similar. Biaxial dynamization with the MSP appears to control fracture impaction effectively and minimizes the rate of postoperative fixation

  13. Dynamic buckling analysis of delaminated composite plates using semi-analytical finite strip method

    NASA Astrophysics Data System (ADS)

    Ovesy, H. R.; Totounferoush, A.; Ghannadpour, S. A. M.

    2015-05-01

    The delamination phenomena can become of paramount importance when the design of the composite plates is concerned. In the current study, the effect of through-the-width delamination on dynamic buckling behavior of a composite plate is studied by implementing semi-analytical finite strip method. In this method, the energy and work integrations are computed analytically due to the implementation of trigonometric functions. Moreover, the method can lead to converged results with comparatively small number of degrees of freedom. These features have made the method quite efficient. To account for delamination effects, displacement field is enriched by adding appropriate terms. Also, the penetration of the delamination surfaces is prevented by incorporating an appropriate contact scheme into the time response analysis. Some selected results are validated against those available in the literature.

  14. Alternative methods for the replacement of eye irritation testing.

    PubMed

    Lotz, Christian; Schmid, Freia F; Rossi, Angela; Kurdyn, Szymon; Kampik, Daniel; De Wever, Bart; Walles, Heike; Groeber, Florian K

    2016-01-01

    In the last decades significant regulatory attempts were made to replace, refine and reduce animal testing to assess the risk of consumer products for the human eye. As the original in vivo Draize eye test has been criticized for limited predictivity, costs and ethical issues, several animal-free test methods have been developed to categorize substances according to the global harmonized system (GHS) for eye irritation.This review summarizes the progress of alternative test methods for the assessment of eye irritation. Based on the corneal anatomy and the current knowledge of the mechanisms causing eye irritation, different ex vivo and in vitro methods will be presented and discussed in regard of possible limitations and their status of regulatory acceptance. In addition to established in vitro models, this review will also highlight emerging, full thickness cornea models that might be applicable to predict all GHS categories. PMID:26626125

  15. Alternate Methods to Experimentally Investigate Shock Initiation Properties of Explosives

    NASA Astrophysics Data System (ADS)

    Svingala, Forrest; Lee, Richard; Sutherland, Gerrit; Samuels, Philip

    2015-06-01

    Reactive flow models are desired for many new explosives early in the formulation development stage. Traditionally, these models are parameterized by carefully-controlled 1-D shock experiments, including gas-gun testing with embedded gauges and wedge testing with explosive plane wave lenses (PWL). These experiments are easy to interpret, due to their 1-D nature, but are generally expensive to perform, and cannot be performed at all explosive test facilities. We investigate alternative methods to probe shock-initiation behavior of new explosives using widely-available pentolite gap test donors and simple time-of-arrival type diagnostics. These methods can be performed at a low cost at virtually any explosives testing facility, which allows experimental data to parameterize reactive flow models to be collected much earlier in the development of an explosive formulation. However, the fundamentally 2-D nature of these tests may increase the modeling burden in parameterizing these models, and reduce general applicability. Several variations of the so-called modified gap test were investigated and evaluated for suitability as an alternative to established 1-D gas gun and PWL techniques. At least partial agreement with 1-D test methods was observed for the explosives tested, and future work is planned to scope the applicability and limitations of these experimental techniques.

  16. Alternative sewerage solution: Condominial method and its application

    NASA Astrophysics Data System (ADS)

    Türker, Umut

    In this study, the fundamental of the theory of condominial sewer design is discussed through a readily available computer program and the theory is used to bring out the effect of pipe diameter and sewer gradient on design calculations through alternative solutions. It is proved that the roughness of the pipe is effective on the size, lifetime, and cost-saving property of the condominial sewer system, whereas the pipe diameter is not a vital parameter for the same criteria. Any expansion on the pipe roughness increased the gradient of flow and thus enlarged the excavation area hence; undermine the cost-saving property of the condominial method.

  17. Evaluation of the 3M Petrifilm Enterobacteriaceae Count plate method for the enumeration of Enterobacteriaceae in foods.

    PubMed

    Silbernagel, Karen M; Lindberg, Kathryn G

    2002-09-01

    Results of the 3M Petrifilm Enterobacteriaceae Count (EB) plate method were compared with those of the standard violet red bile glucose agar (VRBG) method for the detection and enumeration of Enterobacteriaceae. Studies involving 107 bacterial strains demonstrated that the Petrifilm EB plate method is as sensitive as and more selective than the VRBG method. Sixty of the 62 pure Enterobacteriaceae cultures were recovered by both methods. In addition, 38 of the 45 non-Enterobacteriaceae organisms did not grow on the Petrifilm EB plate, while 28 of the 45 non-Enterobacteriaceae organisms did not grow on the VRBG plate. Colony counts from 174 naturally contaminated and 120 artificially inoculated dairy and nondairy food samples showed that the Petrifilm EB plate method performed as well as or better than the standard VRBG method for the enumeration of Enterobacteriaceae. PMID:12233857

  18. Experimental measurements on transverse vibration characteristics of piezoceramic rectangular plates by optical methods

    NASA Astrophysics Data System (ADS)

    Ma, Chien-Ching; Lin, Hsien-Yang

    2005-09-01

    This study provides two non-contact optical techniques to investigate the transverse vibration characteristics of piezoceramic rectangular plates in resonance. These methods, including the amplitude-fluctuation electronic speckle pattern interferometry (AF-ESPI) and laser Doppler vibrometer (LDV), are full-field measurement for AF-ESPI and point-wise displacement measurement for LDV, respectively. The edges of these piezoceramic rectangular plates may either be fixed or free. Both resonant frequencies and mode shapes of vibrating piezoceramic plates can be obtained simultaneously by AF-ESPI. Excellent quality of the interferometric fringe patterns for the mode shapes is obtained. In the LDV system, a built-in dynamic signal analyzer (DSA) composed of DSA software and a plug-in waveform generator board can provide the piezoceramic plates with the swept-sine excitation signal, whose gain at corresponding frequencies is analyzed by the DSA software. The peaks appeared in the frequency response curve are resonant frequencies. In addition to these optical methods, the numerical computation based on the finite element analysis is used to verify the experimental results. Good agreements of the mode shapes and resonant frequencies are obtained for experimental and numerical results.

  19. Buckling analysis of moderately thick rectangular plates using coupled displacement field method

    NASA Astrophysics Data System (ADS)

    Meera Saheb, K.; Aruna, K.

    2015-12-01

    A simple and efficient coupled displacement field method is developed to study the buckling load parameters of the moderately thick rectangular plates. This method has been successfully applied to study the same for the Timoshenko beams. A single term trigonometric admissible displacement field is assumed for one of the variables, say, the total rotations (in both X, Y directions). Making use of the coupling equations, the spatial variation for the remaining lateral displacement field is derived in terms of the total rotations. The coupled displacement field method makes the energy formulation to contains half the number of unknown independent coefficients, in the case of a rectangular plate, contrary to the conventional Rayleigh-Ritz method. The expressions for the non-dimensional buckling load parameters of the moderately thick rectangular plates with all the edges simply supported are derived. The numerical values of these parameters obtained using the coupled displacement field method match very well with open literature demonstrating the effectiveness of the coupled displacement field method.

  20. Waves on Thin Plates: A New (Energy Based) Method on Localization

    NASA Astrophysics Data System (ADS)

    Turkaya, Semih; Toussaint, Renaud; Kvalheim Eriksen, Fredrik; Lengliné, Olivier; Daniel, Guillaume; Grude Flekkøy, Eirik; Jørgen Måløy, Knut

    2016-04-01

    Noisy acoustic signal localization is a difficult problem having a wide range of application. We propose a new localization method applicable for thin plates which is based on energy amplitude attenuation and inversed source amplitude comparison. This inversion is tested on synthetic data using a direct model of Lamb wave propagation and on experimental dataset (recorded with 4 Brüel & Kjær Type 4374 miniature piezoelectric shock accelerometers, 1 - 26 kHz frequency range). We compare the performance of this technique with classical source localization algorithms, arrival time localization, time reversal localization, localization based on energy amplitude. The experimental setup consist of a glass / plexiglass plate having dimensions of 80 cm x 40 cm x 1 cm equipped with four accelerometers and an acquisition card. Signals are generated using a steel, glass or polyamide ball (having different sizes) quasi perpendicular hit (from a height of 2-3 cm) on the plate. Signals are captured by sensors placed on the plate on different locations. We measure and compare the accuracy of these techniques as function of sampling rate, dynamic range, array geometry, signal to noise ratio and computational time. We show that this new technique, which is very versatile, works better than conventional techniques over a range of sampling rates 8 kHz - 1 MHz. It is possible to have a decent resolution (3cm mean error) using a very cheap equipment set. The numerical simulations allow us to track the contributions of different error sources in different methods. The effect of the reflections is also included in our simulation by using the imaginary sources outside the plate boundaries. This proposed method can easily be extended for applications in three dimensional environments, to monitor industrial activities (e.g boreholes drilling/production activities) or natural brittle systems (e.g earthquakes, volcanoes, avalanches).

  1. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies

    PubMed Central

    Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491

  2. Method and apparatus for acoustic plate mode liquid-solid phase transition detection

    DOEpatents

    Blair, Dianna S.; Freye, Gregory C.; Hughes, Robert C.; Martin, Stephen J.; Ricco, Antonio J.

    1993-01-01

    A method and apparatus for sensing a liquid-solid phase transition event is provided which comprises an acoustic plate mode detecting element placed in contact with a liquid or solid material which generates a high-frequency acoustic wave that is attenuated to an extent based on the physical state of the material is contact with the detecting element. The attenuation caused by the material in contact with the acoustic plate mode detecting element is used to determine the physical state of the material being detected. The method and device are particularly suited for detecting conditions such as the icing and deicing of wings of an aircraft. In another aspect of the present invention, a method is provided wherein the adhesion of a solid material to the detecting element can be measured using the apparatus of the invention.

  3. Outcome modelling strategies in epidemiology: traditional methods and basic alternatives.

    PubMed

    Greenland, Sander; Daniel, Rhian; Pearce, Neil

    2016-04-01

    Controlling for too many potential confounders can lead to or aggravate problems of data sparsity or multicollinearity, particularly when the number of covariates is large in relation to the study size. As a result, methods to reduce the number of modelled covariates are often deployed. We review several traditional modelling strategies, including stepwise regression and the 'change-in-estimate' (CIE) approach to deciding which potential confounders to include in an outcome-regression model for estimating effects of a targeted exposure. We discuss their shortcomings, and then provide some basic alternatives and refinements that do not require special macros or programming. Throughout, we assume the main goal is to derive the most accurate effect estimates obtainable from the data and commercial software. Allowing that most users must stay within standard software packages, this goal can be roughly approximated using basic methods to assess, and thereby minimize, mean squared error (MSE). PMID:27097747

  4. Outcome modelling strategies in epidemiology: traditional methods and basic alternatives

    PubMed Central

    Greenland, Sander; Daniel, Rhian; Pearce, Neil

    2016-01-01

    Controlling for too many potential confounders can lead to or aggravate problems of data sparsity or multicollinearity, particularly when the number of covariates is large in relation to the study size. As a result, methods to reduce the number of modelled covariates are often deployed. We review several traditional modelling strategies, including stepwise regression and the ‘change-in-estimate’ (CIE) approach to deciding which potential confounders to include in an outcome-regression model for estimating effects of a targeted exposure. We discuss their shortcomings, and then provide some basic alternatives and refinements that do not require special macros or programming. Throughout, we assume the main goal is to derive the most accurate effect estimates obtainable from the data and commercial software. Allowing that most users must stay within standard software packages, this goal can be roughly approximated using basic methods to assess, and thereby minimize, mean squared error (MSE). PMID:27097747

  5. Alternative methods of reproduction. Effects on the child.

    PubMed

    Sokoloff, B Z

    1987-01-01

    Artificial donor insemination (DI), surrogate parenting, in vitro fertilization, and embryo transfer are alternative methods of reproduction being utilized with increasing frequency. Technological developments are being studied in detail. Because of the secrecy inherent in the families involved, there has been little written describing the emotional and psychological well-being of the participants. Significant factors, such as unlimited pregnancies per donor, lack of recordkeeping of the genetic background of each insemination, need for psychological counseling of the parents, the impact of the "family secret" of the pregnancy, and the well-being of the offspring, have not been adequately addressed. There has been little effort to make use of our experience in adoption in relation to many of these same areas. No medical guidelines or legislation exist. The inherent problems associated with these parenting methods and practices are discussed along with recommendations for improvement. PMID:3791832

  6. ALTERNATIVE METHOD FOR RIVER TRAINING WORKS: BANDAL-LIKE STRUCTURES

    NASA Astrophysics Data System (ADS)

    Teraguchi, Hiroshi; Nakagawa, Hajime; Kawaike, Kenji; Baba, Yasuyuki; Zhang, Hao

    In this paper, the applicability of bandal-like structures as an alternative method for traditional river training structures like groins is investigated. This structure is usually used in Indian Sub-Continents for riverbank protection and improvement of navigation conditions in alluvial rivers. The mechanism behind the utilization of this type of structure which affects the flow patterns and sediment transport process was studied through experimental measurements and numerical simulations. During the calculations, the water flow is computed by solving the Reynolds-averaged Navier-Stokes equations in 3D domain. The k model is used for the turbulence closure and the numerical simulation is conducted on the unstructured meshes with the finite volume method. The main characteristics of the sediment erosion/deposition process around the bandal-like structures are clarified. The promising use of bandal-like structures is demonstrated through the comparisons with conventional structures as impermeable groins.

  7. Feasibility study on welding and cutting methods for thick plate in fusion reactor

    SciTech Connect

    Osaki, T.; Nakayama, Y.; Kobayashi, T.

    1995-12-31

    Application of tungsten-arc inert-gas (TIG) welding with narrow gap has been considered as a hopeful joint method to suppress post welding deformation for thick plates. The authors studied some parameters to predict the post-welding deformation for the narrow gap shape of TIG welding. As for cutting methods, the water jet method was applied for weld joints in this study. Reweld tests by using the TIG welding method were successfully performed under the condition of cutting surface as it was. Results of tensile tests for reweld joints showed no reduction in strength. This reveals a good prospect of providing reweld groove surface without any machining on site.

  8. Heteroepitaxial growth of LiNbO 3 single crystal films by ion plating method

    NASA Astrophysics Data System (ADS)

    Matsunaga, H.; Ohno, H.; Okamoto, Y.; Nakajima, Y.

    1990-01-01

    Lithium niobate (LiNbO 3) thin films were deposited on several different substrates such as glass (Corning 7059), α-Al 2O 3 (R- and Z-plate), MgO(111) and ZnO(001) by an ion plating method. The crystallinity and compositional fluctuation of the deposited films have been examined by X-ray diffraction, RHEED and SIMS. Consequently, it has been confirmed that the heteroepitaxial growth of LiNbO 3 occurs on the above crystalline substrates, despite large lattice mismatches (≈8.2%). The orientation relationships between the epitaxial layers and the substrates are as follows: (1) (012)LiNbO 3⌈(012)α-Al 2O 3(R-plate), [100]LiNbO 3⌈[100]α-Al 2O 3; (2) (001)LiNbO 3⌈(001)α-Al 2O 3(Z-plate), [100]LiNbO 3⌈[100]α-Al 2O 3; (3) (001)LiNbO 3⌈(111)MgO,[110]LiNbO 3⌈[ overline211]MgO; (4) (001)LiNbO 3⌈(001)ZnO, [110]LiNbO 3⌈[210]ZnO, respectively.

  9. Three-beam interferogram analysis method for surface flatness testing of glass plates and wedges

    NASA Astrophysics Data System (ADS)

    Sunderland, Zofia; Patorski, Krzysztof

    2015-09-01

    When testing transparent plates with high quality flat surfaces and a small angle between them the three-beam interference phenomenon is observed. Since the reference beam and the object beams reflected from both the front and back surface of a sample are detected, the recorded intensity distribution may be regarded as a sum of three fringe patterns. Images of that type cannot be succesfully analyzed with standard interferogram analysis methods. They contain, however, useful information on the tested plate surface flatness and its optical thickness variations. Several methods were elaborated to decode the plate parameters. Our technique represents a competitive solution which allows for retrieval of phase components of the three-beam interferogram. It requires recording two images: a three-beam interferogram and the two-beam one with the reference beam blocked. Mutually subtracting these images leads to the intensity distribution which, under some assumptions, provides access to the two component fringe sets which encode surfaces flatness. At various stages of processing we take advantage of nonlinear operations as well as single-frame interferogram analysis methods. Two-dimensional continuous wavelet transform (2D CWT) is used to separate a particular fringe family from the overall interferogram intensity distribution as well as to estimate the phase distribution from a pattern. We distinguish two processing paths depending on the relative density of fringe sets which is connected with geometry of a sample and optical setup. The proposed method is tested on simulated data.

  10. Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

    NASA Technical Reports Server (NTRS)

    Yu, Lingyu; Tian, Zhenhua; Leckey, Cara A. C.

    2015-01-01

    Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

  11. Damage localization in a glass fiber reinforced composite plate via the surface interpolation method

    NASA Astrophysics Data System (ADS)

    Limongelli, M. P.; Carvelli, V.

    2015-07-01

    This work deals with the application to composite plates of the surface interpolation method (SIM) for damage localization. The procedure, which is a generalization to the two-dimensional case of the previously published Interpolation Damage Detection Method (IDDM), locates reductions of stiffness in two-dimensional structures such as plates. The method is based on the damage sensitive of a spline function accuracy in fitting the operational displacement shapes, relies on the so-called Gibbs’ phenomenon for splines. This phenomenon occurs when a spline function interpolates discontinuous functions and consists in sharp oscillations and overshoots (values higher than those of the function to be interpolated) near a discontinuous point. The operational deformed shapes are recovered from frequency response functions (FRF's) measured at different locations of the structure during vibrations. The accuracy of the spline interpolation is measured by an error function defined as the difference between the measured and interpolated operational deformed shapes. At a certain location an increase (statistically meaningful) of the interpolation error, with respect to a reference configuration, points out a localized variation of the operational shapes thus revealing the existence of damage. The accuracy of the surface interpolation method is experimentally assessed by impact hammer tests on glass fiber/vinylester composite plates progressively damaged and using finite element numerical modelling.

  12. An Asymptotic-Numerical Method for Large-Amplitude Free Vibrations of Thin Elastic Plates

    NASA Astrophysics Data System (ADS)

    Azrar, L.; Benamar, R.; Potier-Ferry, M.

    1999-03-01

    An Asymptotic-Numerical Method has been developed for large amplitude free vibrations of thin elastic plates. It is based on the perturbation method and the finite element method. This method eliminates the major difficulties of the classical perturbation methods, namely the complexity of the right hand sides and the limitation of the validity of the solution obtained. The applicability of this method to non-linear vibrations of plates is clearly presented. Based on the Von Karman theory and the harmonic balance method, a cubic non-linear operational formulation has been obtained. By using the mixed stress-displacement Hellinger-Reissner principle, a quadratic formulation is given. The displacement and frequency are expanded into power series with respect to a control parameter. The non-linear governing equation is then transformed into a sequence of linear problems having the same stiffness matrix, which can be solved by a classical FEM. Needing one matrix inversion, a large number of terms of the series can be easily computed with a small computation time. The non-linear mode and frequency are then obtained up to the radius of convergence. Taking the starting point in the zone of validity, the method is reapplied in order to determine a further part of the non-linear solution. Iteration of this method leads to a powerful incremental method. In order to increase the validity of the perturbed solution, another technique, called Padé approximants, is shrewdly incorporated. The solutions obtained by these two concepts coincide perfectly in a very large part of the backbone curve. Comprehensive numerical tests for non-linear free vibrations of circular, square, rectangular and annular plates with various boundary conditions are reported and discussed.

  13. Method for measuring retardation of infrared wave-plate by modulated-polarized visible light

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Song, Feijun

    2012-11-01

    A new method for precisely measuring the optical phase retardation of wave-plates in the infrared spectral region is presented by using modulated-polarized visible light. An electro-optic modulator is used to accurately determine the zero point by the frequency-doubled signal of the Modulated-polarized light. A Babinet-Soleil compensator is employed to make the phase delay compensation. Based on this method, an instrument is set up to measure the retardations of the infrared wave-plates with visible region laser. Measurement results with high accuracy and sound repetition are obtained by simple calculation. Its measurement precision is less than and repetitive precision is within 0.3%.

  14. Developments in variational methods for high performance plate and shell elements

    NASA Technical Reports Server (NTRS)

    Felippa, Carlos A.; Militello, Carmelo

    1991-01-01

    High performance elements are simple finite elements constructed to deliver engineering accuracy with coarse arbitrary grids. This is part of a series on the variational foundations of high-performance elements, with emphasis on plate and shell elements constructed with the free formulation (FF) and assumed natural strain (ANS) methods. Parameterized variational principles are studied that provide a common foundation for the FF and ANS methods, as well as for a combination of both. From this unified formulation a variant of the ANS formulation, called the assumed natural deviatoric strain (ANDES) formulation, emerges as an important special case. The first ANDES element, a high-performance 9 degrees of freedom triangular Kirchhoff plate bending element, is briefly described to illustrate the use of the new formulation.

  15. Probabilistic fracture investigation of symmetric angle ply laminated composite plates using displacement correlation method

    NASA Astrophysics Data System (ADS)

    Lal, Achchhe; Palekar Shailesh, P.

    2016-01-01

    The second order statistics of mixed mode stress intensity factors (MSIF) of single edge V-notched angle ply laminated composite plate subjected to uniaxial tensile load with uncertinity in the system properties using displacement correlation method (DCM) is evaluated. The random system properties such as material properties, crack opening and crack length are modelled as combined uncorrelated and correlated random system variables. A C0 finite element method (FEM) based on higher order shear deformation plate theory (HSDT) is used for basic formulation. The Taylor series based first order perturbation technique (FOPT), second order perturbation technique (SOPT) are used and direct Monte Carlo simulation (MCS) is performed to evaluate the statistics (mean and coefficient of variance) of the mixed mode SIFs. The present work signifies the accurate analysis of frature behaviour by influence of different random variables and fibre orientations on the fracture behaviour in angle ply laminates.

  16. Determination of Rock Mass Modulus Using the Plate Loading Method at Yucca Mountain, Nevada

    SciTech Connect

    Finley, R.E.; George, J.T.; Riggins, M.

    1999-08-02

    A suite of plate loading tests has recently been conducted by Sandia National Laboratories at the Exploratory Studies Facility at Yucca Mountain, Nevada. Fielding of these in situ tests as well as other approaches undertaken for the determination of rock mass modulus are described. The various methodologies are evaluated and their data compared. Calculation by existing empirical methods and numerical modeling are compared to each other as well as to field data.

  17. Effective microwell plate-based screening method for microbes producing cellulase and xylanase and its application.

    PubMed

    Kim, Jennifer Jooyoun; Kwon, Young-Kyung; Kim, Ji Hyung; Heo, Soo-Jin; Lee, Youngdeuk; Lee, Su-Jin; Shim, Won-Bo; Jung, Won-Kyo; Hyun, Jung-Ho; Kwon, Kae Kyoung; Kang, Do-Hyung; Oh, Chulhong

    2014-11-28

    Cellulase and xylanase are main hydrolysis enzymes for the degradation of cellulosic and hemicellulosic biomass, respectively. In this study, our aim was to develop and test the efficacy of a rapid, high-throughput method to screen hydrolytic-enzyme-producing microbes. To accomplish this, we modified the 3,5-dinitrosalicylic acid (DNS) method for microwell plate-based screening. Targeted microbial samples were initially cultured on agar plates with both cellulose and xylan as substrates. Then, isolated colonies were subcultured in broth media containing yeast extract and either cellulose or xylan. The supernatants of the culture broth were tested with our modified DNS screening method in a 96-microwell plate, with a 200 μl total reaction volume. In addition, the stability and reliability of glucose and xylose standards, which were used to determine the enzymatic activity, were studied at 100°C for different time intervals in a dry oven. It was concluded that the minimum incubation time required for stable color development of the standard solution is 20 min. With this technique, we successfully screened 21 and 31 cellulase- and xylanase-producing strains, respectively, in a single experimental trial. Among the identified strains, 19 showed both cellulose and xylan hydrolyzing activities. These microbes can be applied to bioethanol production from cellulosic and hemicellulosic biomass. PMID:25085570

  18. Understanding Alternative Education: A Mixed Methods Examination of Student Experiences

    ERIC Educational Resources Information Center

    Glassett Farrelly, Susan

    2013-01-01

    Alternative schools operate today as a hidden, parallel educational system, providing a separate and often unequal education to many at-risk students, with little to no accountability. The number of alternative schools, and enrollment in alternative schools, is increasing, due in part to excessive use of zero tolerance policies. Students of color,…

  19. An alternate high yielding purification method for Clitoria ternatea lectin.

    PubMed

    Naeem, Aabgeena; Ahmad, Ejaz; Khan, Rizwan Hasan

    2007-10-01

    In our previous publication we had reported the purification and characterization of Clitoria ternatea agglutinin from its seeds on fetuin CL agarose affinity column, designated CTA [A. Naeem, S. Haque, R.H. Khan. Protein J., 2007]. Since CTA binds beta-d-galactosides, this lectin can be used as valuable tool for glycobiology studies in biomedical and cancer research. So an attempt was made for a high yielding alternative purification method employing the use of asialofetuin CL agarose column for the above-mentioned lectin, designated CTL. The fetuin affinity purified agglutinin was found similar to asialofetuin affinity purified lectin in SDS pattern, HPLC and N-terminal sequence. The content of lectin was found to be 30mg/30g dry weight of pulse. The yield was 2.8% as compared to 0.3% obtained on fetuin column. The number of tryptophan and tyrosine estimated was four and six per subunit. PMID:17590430

  20. ALTERNATIVE FIELD METHODS TO TREAT MERCURY IN SOIL

    SciTech Connect

    Ernest F. Stine Jr; Steven T. Downey

    2002-08-14

    U.S. Department of Energy (DOE) used large quantities of mercury in the uranium separating process from the 1950s until the late 1980s in support of national defense. Some of this mercury, as well as other hazardous metals and radionuclides, found its way into, and under, several buildings, soil and subsurface soils and into some of the surface waters. Several of these areas may pose potential health or environmental risks and must be dealt with under current environmental regulations. DOE's National Energy Technology Laboratory (NETL) awarded a contract ''Alternative Field Methods to Treat Mercury in Soil'' to IT Group, Knoxville TN (IT) and its subcontractor NFS, Erwin, TN to identify remedial methods to clean up mercury-contaminated high-clay content soils using proven treatment chemistries. The sites of interest were the Y-12 National Security Complex located in Oak Ridge, Tennessee, the David Witherspoon properties located in Knoxville, Tennessee, and at other similarly contaminated sites. The primary laboratory-scale contract objectives were (1) to safely retrieve and test samples of contaminated soil in an approved laboratory and (2) to determine an acceptable treatment method to ensure that the mercury does not leach from the soil above regulatory levels. The leaching requirements were to meet the TC (0.2 mg/l) and UTS (0.025 mg/l) TCLP criteria. In-situ treatments were preferred to control potential mercury vapors emissions and liquid mercury spills associated with ex-situ treatments. All laboratory work was conducted in IT's and NFS laboratories. Mercury contaminated nonradioactive soil from under the Alpha 2 building in the Y-12 complex was used. This soils contained insufficient levels of leachable mercury and resulted in TCLP mercury concentrations that were similar to the applicable LDR limits. The soil was spiked at multiple levels with metallic (up to 6000 mg/l) and soluble mercury compounds (up to 500 mg/kg) to simulate expected ranges of mercury

  1. An alternative numerical method for the stationary pulsar magnetosphere

    NASA Astrophysics Data System (ADS)

    Takamori, Yohsuke; Okawa, Hirotada; Takamoto, Makoto; Suwa, Yudai

    2014-02-01

    Stationary pulsar magnetospheres in the force-free system are governed by the pulsar equation. In 1999, Contopoulos, Kazanas, and Fendt (hereafter CKF) numerically solved the pulsar equation and obtained a pulsar magnetosphere model called the CKF solution that has both closed and open magnetic field lines. The CKF solution is a successful solution, but it contains a poloidal current sheet that flows along the last open field line. This current sheet is artificially added to make the current system closed. In this paper, we suggest an alternative method to solve the pulsar equation and construct pulsar magnetosphere models without a current sheet. In our method, the pulsar equation is decomposed into Ampère's law and the force-free condition. We numerically solve these equations simultaneously with a fixed poloidal current. As a result, we obtain a pulsar magnetosphere model without a current sheet, which is similar to the CKF solution near the neutron star and has a jet-like structure at a distance along the pole. In addition, we discuss physical properties of the model and find that the force-free condition breaks down in a vicinity of the light cylinder due to dissipation that is included implicitly in the numerical method.

  2. An Alternate Approach to Alternating Sums: A Method to DIE for

    ERIC Educational Resources Information Center

    Benjamin, Arthur T.; Quinn, Jennifer J.

    2008-01-01

    Positive sums count. Alternating sums match. Alternating sums of binomial coefficients, Fibonacci numbers, and other combinatorial quantities are analyzed using sign-reversing involutions. In particular, we describe the quantity being considered, match positive and negative terms through an Involution, and count the Exceptions to the matching rule…

  3. Method for preparing surfaces of metal composites having a brittle phase for plating

    DOEpatents

    Coates, Cameron W.; Wilson, Thomas J.

    1984-01-01

    The present invention is directed to a method for preparing surfaces of two-phase metal composites having relatively brittle and malleable components for plating with corrosion-resistant material. In practice of the present invention, the surfaces of the composites are etched to remove a major portion or fraction of the brittle component. The etched surface is then peened with particulates for breaking the brittle component from the surfaces and for spreading or smearing the malleable component over the surfaces. The peened surface is then chemically cleaned of residual traces of the brittle component so as to provide a surface of essentially the malleable component to which the corrosion-resistant material may be plated thereon in an adherent manner.

  4. Micro-Macro Analysis of Viscoelastic Unidirectional Laminated Composite Plates Using DR Method

    NASA Astrophysics Data System (ADS)

    Falahatgar, Seyed Reza; Salehi, Manouchehr; Aghdam, Mohammad Mohammadi

    2010-10-01

    The Dynamic Relaxation (DR) technique together with finite difference discritization is used to study the bending behavior of Mindlin composite plate including geometric nonlinearity. The overall behavior of the unidirectional composite is obtained from a three-dimensional (3D) micromechanical model, in any combination of normal and shear loading conditions, based on the assumptions of Simplified Unit Cell Method (SUCM). The composite system consists of nonlinear viscoelastic matrix reinforced by transversely isotropic elastic fibers. A recursive formulation for the hereditary integral of the Schapery viscoelastic constitutive equation in multiaxial stress state is used to model the nonlinear viscoelastic matrix material in the material level. The creep tests data is used for verification of the predicted response of the current approach. Under uniform lateral pressure, the laminated plate deformation with clamped and hinged edged constraints is predicted for various time steps.

  5. ALTERNATIVE FIELD METHODS TO TREAT MERCURY IN SOIL

    SciTech Connect

    Ernie F. Stine

    2002-08-14

    The Department of Energy (DOE) currently has mercury (Hg) contaminated materials and soils at the various sites. Figure 1-1 (from http://www.ct.ornl.gov/stcg.hg/) shows the estimated distribution of mercury contaminated waste at the various DOE sites. Oak Ridge and Idaho sites have the largest deposits of contaminated materials. The majorities of these contaminated materials are soils, sludges, debris, and waste waters. This project concerns treatment of mercury contaminated soils. The technology is applicable to many DOE sites, in-particular, the Y-12 National Security Complex in Oak Ridge Tennessee and Idaho National Engineering and Environmental Laboratory (INEEL). These sites have the majority of the soils and sediments contaminated with mercury. The soils may also be contaminated with other hazardous metals and radionuclides. At the Y12 plant, the baseline treatment method for mercury contaminated soil is low temperature thermal desorption (LTTD), followed by on-site landfill disposal. LTTD is relatively expensive (estimated cost of treatment which exclude disposal cost for the collect mercury is greater than $740/per cubic yard [cy] at Y-12), does not treat any of the metal or radionuclides. DOE is seeking a less costly alternative to the baseline technology. As described in the solicitation (DE-RA-01NT41030), this project initially focused on evaluating cost-effective in-situ alternatives to stabilize or remove the mercury (Hg) contamination from high-clay content soil. It was believed that ex-situ treatment of soil contaminated with significant quantities of free-liquid mercury might pose challenges during excavation and handling. Such challenges may include controlling potential mercury vapors and containing liquid mercury beads. As described below, the focus of this project was expanded to include consideration of ex-situ treatment after award of the contract to International Technology Corporation (IT). After award of the contract, IT became part of Shaw

  6. Combining sources in stable isotope mixing models: alternative methods.

    PubMed

    Phillips, Donald L; Newsome, Seth D; Gregg, Jillian W

    2005-08-01

    Stable isotope mixing models are often used to quantify source contributions to a mixture. Examples include pollution source identification; trophic web studies; analysis of water sources for soils, plants; or water bodies, and many others. A common problem is having too many sources to allow a unique solution. We discuss two alternative procedures for addressing this problem. One option is a priori to combine sources with similar signatures so the number of sources is small enough to provide a unique solution. Aggregation should be considered only when isotopic signatures of clustered sources are not significantly different, and sources are related so the combined source group has some functional significance. For example, in a food web analysis, lumping several species within a trophic guild allows more interpretable results than lumping disparate food sources, even if they have similar isotopic signatures. One result of combining mixing model sources is increased uncertainty of the combined end-member isotopic signatures and consequently the source contribution estimates; this effect can be quantified using the IsoError model (http://www.epa.gov/wed/pages/models/isotopes/isoerror1_04.htm). As an alternative to lumping sources before a mixing analysis, the IsoSource mixing model (http://www.epa.gov/wed/pages/models/isosource/isosource.htm) can be used to find all feasible solutions of source contributions consistent with isotopic mass balance. While ranges of feasible contributions for each individual source can often be quite broad, contributions from functionally related groups of sources can be summed a posteriori, producing a range of solutions for the aggregate source that may be considerably narrower. A paleo-human dietary analysis example illustrates this method, which involves a terrestrial meat food source, a combination of three terrestrial plant foods, and a combination of three marine foods. In this case, a posteriori aggregation of sources allowed

  7. 77 FR 40358 - Meeting of the Scientific Advisory Committee on Alternative Toxicological Methods (SACATM)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-09

    ... HUMAN SERVICES Meeting of the Scientific Advisory Committee on Alternative Toxicological Methods (SACATM..., revised, and alternative safety testing methods with regulatory applicability and promotes the scientific..., provides scientific and operational support for ICCVAM-related activities, and conducts...

  8. Error compensation of thin plate-shape part with prebending method in face milling

    NASA Astrophysics Data System (ADS)

    Yi, Wei; Jiang, Zhaoliang; Shao, Weixian; Han, Xiangcheng; Liu, Wenping

    2015-01-01

    Low weight and good toughness thin plate parts are widely used in modern industry, but its flexibility seriously impacts the machinability. Plenty of studies focus on the influence of machine tool and cutting tool on the machining errors. However, few researches focus on compensating machining errors through the fixture. In order to improve the machining accuracy of thin plate-shape part in face milling, this paper presents a novel method for compensating the surface errors by prebending the workpiece during the milling process. First, a machining error prediction model using finite element method is formulated, which simplifies the contacts between the workpiece and fixture with spring constraints. Milling forces calculated by the micro-unit cutting force model are loaded on the error prediction model to predict the machining error. The error prediction results are substituted into the given formulas to obtain the prebending clamping forces and clamping positions. Consequently, the workpiece is prebent in terms of the calculated clamping forces and positions during the face milling operation to reduce the machining error. Finally, simulation and experimental tests are carried out to validate the correctness and efficiency of the proposed error compensation method. The experimental measured flatness results show that the flatness improves by approximately 30 percent through this error compensation method. The proposed method not only predicts the machining errors in face milling thin plate-shape parts but also reduces the machining errors by taking full advantage of the workpiece prebending caused by fixture, meanwhile, it provides a novel idea and theoretical basis for reducing milling errors and improving the milling accuracy.

  9. 3M Petrifilm enterobacteriaceae count plate method for enumeration of enterobacteriaceae in selected foods: collaborative study.

    PubMed

    Silbernagel, Karen M; Lindberg, Kathryn G

    2003-01-01

    The practice of detecting and enumerating all oxidase-negative, glucose-fermenting-Gram-negative rods (i.e., the family Enterobacteriaceae) is used to indicate unsanitary or inadequate food processing conditions. The objective of this interlaboratory collaborative study was to evaluate and compare the methods described in Standard Methods for the Examination of Dairy Products (SMEDP) and the Compendium of Methods for the Microbiological Examination of Foods (Compendium) with a commercial product, the 3M Petrifilm Enterobacteriaceae Count Plate, for the recovery of Enterobacteriaceae in foods. Six foods--cheddar cheese, milk, flour, frozen prepared meals, frozen broccoli, and nut pieces--were analyzed for Enterobacteriaceae by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test portions consisting of a control test portion and 3 levels of inoculated test portion, each in duplicate. Each test portion was tested by the Petrifilm Enterobacteriaceae Count Plate method as well as the SMEDP or Compendium methods. The precision estimates (repeatability or within-laboratory variation, and reproducibility or between-laboratory variation) were calculated with standard statistical techniques. PMID:14509441

  10. Damage localisation in plate like-structures using the two-dimensional polynomial annihilation edge detection method

    NASA Astrophysics Data System (ADS)

    Surace, C.; Saxena, R.; Gherlone, M.; Darwich, H.

    2014-10-01

    The topic of non-destructively detecting localised damage in plates is addressed in this article. Since the presence of a crack or a delamination causes a discontinuity in the mode shape first derivatives, a numerical method for detecting discontinuities in smooth piecewise functions and their derivatives, based on a polynomial-annihilation technique is presented. The method, already proposed for beam-type structures, has been extended to enable the detection and localisation of damage in plate-like structures for which only post-damage mode shapes are available. Applying finite element analysis, the mode shapes of an isotropic plate with a saw-cut and a multi-layered composite plate with a delamination have been calculated and the performance of the approach evaluated for increasing amounts of noise. Encouraging results indicate that further development of the technique for non-destructive testing of plate-like structures would be highly worthwhile.

  11. Apparatus and method for explosive bonding to edge of flyer plate

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J. (Inventor); Kushnick, Anne C. (Inventor)

    1991-01-01

    The invention is an apparatus and a process for the explosive joining of a flyer plate and a base plate. The apparatus consists of a flyer plate positioned over a base plate. The flyer plate has a notch containing a filler material in intimate contact with the flyer plate. An adhesive means holds a ribbon explosive partially overlapping the notch in the flyer plate. A detonating means initiates the ribbon explosive that drives the flyer plate to accomplish a high velocity, angular collision between the mating surfaces. This collision creates surface melts and effacing bonding, resulting in electron sharing linkups between the plates. An unbonded tab fractures at a base of the notch leaving a bond to an edge of the attached flyer plate.

  12. 78 FR 68076 - Request for Information on Alternative Skin Sensitization Test Methods and Testing Strategies and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-13

    ...The Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) is developing a U.S. plan for the evaluation of alternative skin sensitization test methods and testing strategies. The National Toxicology Program (NTP) Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM) requests information that ICCVAM might use to develop this plan and......

  13. Phototoxicity: Its Mechanism and Animal Alternative Test Methods.

    PubMed

    Kim, Kyuri; Park, Hyeonji; Lim, Kyung-Min

    2015-06-01

    The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential. PMID:26191378

  14. Phototoxicity: Its Mechanism and Animal Alternative Test Methods

    PubMed Central

    Park, Hyeonji; Lim, Kyung-Min

    2015-01-01

    The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential. PMID:26191378

  15. Comparison of Diverse Differential Plating Methods to Enrich Bovine Spermatogonial Cells.

    PubMed

    Giassetti, M I; Goissis, M D; de Barros, Fro; Bruno, A H; Assumpção, Meoa; Visintin, J A

    2016-02-01

    Spermatogonial stem cells (SSC) have important applications in domestic animal reproduction and advanced biotechnologies. Because differential plating is one of the most common methods used for SSC enrichment, the goal of this study was to compare three differential plating methods for the enrichment of bovine SSC. To achieve this goal, testicular parenchyma from pre-pubertal calves was minced and single cells were obtained after two enzymatic digestions. We compared three coating methods for differential plating: laminin (20 ng/ml), BSA (0.05 mg/ml) and PBS. Cells were incubated at 37°C, 5% CO2 in air for 15 min onto laminin-coated dishes or 2 h onto BSA- or PBS-coated dishes. Cell viability was assessed by trypan blue exclusion method. Recovered cells were analysed for the expression of SSC molecular markers by quantitative RT-PCR (GFRA1, CXCR4, ITGA6, THY1) and flow cytometry (GFRA1, CXCR4 and ITGA6). Cells at time 0, adherent cells on laminin and non-adherent cells from BSA and PBS groups had the same cell viability (p = 0.0655). GFRA1, CXCR4 and THY1 relative gene expression was higher (p = 0.0402, p = 0.0007, p = 0.0117, respectively) for non-adherent cells selected in PBS group. Flow cytometry analysis revealed that the presence of GFRA-positive (GFRA+) cells was higher in non-adherent cells from BSA and PBS groups (p < 0.001). However, laminin-adherent cells had higher number of ITGA6+ cells (p < 0.001) and lower presence of CXCR4+ cells (p = 0.0012). In conclusion, differential plating is an effective method for the enrichment of bovine undifferentiated spermatogonia and higher expression of SSC markers is obtained without laminin or BSA coating. PMID:26576932

  16. An alternative calibration method for counting P-32 reactor monitors

    SciTech Connect

    Quirk, T.J.; Vehar, D.W.

    2011-07-01

    Radioactivation of sulfur is a common technique used to measure fast neutron fluences in test and research reactors. Elemental sulfur can be pressed into pellets and used as monitors. The {sup 32}S(n, p) {sup 32}P reaction has a practical threshold of about 3 MeV and its cross section and associated uncertainties are well characterized [1]. The product {sup 32P} emits a beta particle with a maximum energy of 1710 keV [2]. This energetic beta particle allows pellets to be counted intact. ASTM Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32 (E265) [3] details a method of calibration for counting systems and subsequent analysis of results. This method requires irradiation of sulfur monitors in a fast-neutron field whose spectrum and intensity are well known. The resultant decay-corrected count rate is then correlated to the known fast neutron fluence. The Radiation Metrology Laboratory (RML) at Sandia has traditionally performed calibration irradiations of sulfur pellets using the {sup 252}Cf spontaneous fission neutron source at the National Inst. of Standards and Technology (NIST) [4] as a transfer standard. However, decay has reduced the intensity of NIST's source; thus lowering the practical upper limits of available fluence. As of May 2010, neutron emission rates have decayed to approximately 3 e8 n/s. In practice, this degradation of capabilities precludes calibrations at the highest fluence levels produced at test reactors and limits the useful range of count rates that can be measured. Furthermore, the reduced availability of replacement {sup 252}Cf threatens the long-term viability of the NIST {sup 252}Cf facility for sulfur pellet calibrations. In lieu of correlating count rate to neutron fluence in a reference field the total quantity of {sup 32}P produced in a pellet can be determined by absolute counting methods. This offers an attractive alternative to extended {sup 252}Cf exposures because it

  17. Extended layerwise method for laminated composite plates with multiple delaminations and transverse cracks

    NASA Astrophysics Data System (ADS)

    Li, D. H.; Zhang, X.; Sze, K. Y.; Liu, Y.

    2016-07-01

    In this paper, the extended layerwise method (XLWM), which was developed for laminated composite beams with multiple delaminations and transverse cracks (Li et al. in Int J Numer Methods Eng 101:407-434, 2015), is extended to laminated composite plates. The strong and weak discontinuous functions along the thickness direction are adopted to simulate multiple delaminations and interlaminar interfaces, respectively, whilst transverse cracks are modeled by the extended finite element method (XFEM). The interaction integral method and maximum circumferential tensile criterion are used to calculate the stress intensity factor (SIF) and crack growth angle, respectively. The XLWM for laminated composite plates can accurately predicts the displacement and stress fields near the crack tips and delamination fronts. The thickness distribution of SIF and thus the crack growth angles in different layers can be obtained. These information cannot be predicted by using other existing shell elements enriched by XFEM. Several numerical examples are studied to demonstrate the capabilities of the XLWM in static response analyses, SIF calculations and crack growth predictions.

  18. The European Partnership for Alternative Approaches to Animal Testing (EPAA): Promoting Alternative Methods in Europe and Beyond

    PubMed Central

    Cozigou, Gwenole; Crozier, Jonathan; Hendriksen, Coenraad; Manou, Irene; Ramirez-Hernandez, Tzutzuy; Weissenhorn, Renate

    2015-01-01

    Here in we introduce the European Partnership for Alternative Approaches to Animal Testing (EPAA) and its activities, which are focused on international cooperation toward alternative methods. The EPAA is one of the leading organizations in Europe for the promotion of alternative approaches to animal testing. Its innovative public–private partnership structure enables a consensus-driven dialogue across 7 industry sectors to facilitate interaction between regulators and regulated stakeholders. Through a brief description of EPAA's activities and organizational structure, we first articulate the value of this collaboration; we then focus on 2 key projects driven by EPAA. The first project aims to address research gaps on stem cells for safety testing, whereas the second project strives for an approach toward demonstration of consistency in vaccine batch release testing. We highlight the growing need for harmonization of international acceptance and implementation of alternative approaches and for increased international collaboration to foster progress on nonanimal alternatives. PMID:25836968

  19. The European Partnership for Alternative Approaches to Animal Testing (EPAA): promoting alternative methods in Europe and beyond.

    PubMed

    Cozigou, Gwenole; Crozier, Jonathan; Hendriksen, Coenraad; Manou, Irene; Ramirez-Hernandez, Tzutzuy; Weissenhorn, Renate

    2015-03-01

    Here in we introduce the European Partnership for Alternative Approaches to Animal Testing (EPAA) and its activities, which are focused on international cooperation toward alternative methods. The EPAA is one of the leading organizations in Europe for the promotion of alternative approaches to animal testing. Its innovative public-private partnership structure enables a consensus-driven dialogue across 7 industry sectors to facilitate interaction between regulators and regulated stakeholders. Through a brief description of EPAA's activities and organizational structure, we first articulate the value of this collaboration; we then focus on 2 key projects driven by EPAA. The first project aims to address research gaps on stem cells for safety testing, whereas the second project strives for an approach toward demonstration of consistency in vaccine batch release testing. We highlight the growing need for harmonization of international acceptance and implementation of alternative approaches and for increased international collaboration to foster progress on nonanimal alternatives. PMID:25836968

  20. Alternative method for VIIRS Moon in space view process

    NASA Astrophysics Data System (ADS)

    Anderson, Samuel; Chiang, Kwofu V.; Xiong, Xiaoxiong

    2013-09-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) is a radiometric sensing instrument currently operating onboard the Suomi National Polar-orbiting Partnership (S-NPP) spacecraft. It provides high spatial-resolution images of the emitted and reflected radiation from the Earth and its atmosphere in 22 spectral bands (16 moderate resolution bands M1-M16, 5 imaging bands I1-I5, and 1 day/night pan band DNB) spanning the visible and infrared wavelengths from 412 nm to 12 μm. Just prior to each scan it makes of the Earth, the VIIRS instrument makes a measurement of deep space to serve as a background reference. These space view (SV) measurements form a crucial input to the VIIRS calibration process and are a major determinant of its accuracy. On occasion, the orientation of the Suomi NPP spacecraft coincides with the position of the moon in such a fashion that the SV measurements include light from the moon, rendering the SV measurements unusable for calibration. This paper investigates improvements to the existing baseline SV data processing algorithm of the Sensor Data Record (SDR) processing software. The proposed method makes use of a Moon-in-SV detection algorithm that identifies moon-contaminated SV data on a scan-by-scan basis. Use of this algorithm minimizes the number of SV scans that are rejected initially, so that subsequent substitution processes are always able to find alternative substitute SV scans in the near vicinity of detected moon-contaminated scans.

  1. Alternate Methods in Refining the SLS Nozzle Plug Loads

    NASA Technical Reports Server (NTRS)

    Burbank, Scott; Allen, Andrew

    2013-01-01

    Numerical analysis has shown that the SLS nozzle environmental barrier (nozzle plug) design is inadequate for the prelaunch condition, which consists of two dominant loads: 1) the main engines startup pressure and 2) an environmentally induced pressure. Efforts to reduce load conservatisms included a dynamic analysis which showed a 31% higher safety factor compared to the standard static analysis. The environmental load is typically approached with a deterministic method using the worst possible combinations of pressures and temperatures. An alternate probabilistic approach, utilizing the distributions of pressures and temperatures, resulted in a 54% reduction in the environmental pressure load. A Monte Carlo simulation of environmental load that used five years of historical pressure and temperature data supported the results of the probabilistic analysis, indicating the probabilistic load is reflective of a 3-sigma condition (1 in 370 probability). Utilizing the probabilistic load analysis eliminated excessive conservatisms and will prevent a future overdesign of the nozzle plug. Employing a similar probabilistic approach to other design and analysis activities can result in realistic yet adequately conservative solutions.

  2. Alternative processing methods for tungsten-base composite materials

    SciTech Connect

    Ohriner, E.K.; Sikka, V.K.

    1995-12-31

    Tungsten composite materials contain large amounts of tungsten distributed in a continuous matrix phase. Current commercial materials include the tungsten-nickel-iron with cobalt replacing some or all of the iron, and also tungsten-copper materials. Typically, these are fabricated by liquid-phase sintering of blended powders. Liquid-phase sintering offers the advantages of low processing costs, established technology, and generally attractive mechanical properties. However, liquid-phase sintering is restricted to a very limited number of matrix alloying elements and a limited range of tungsten and alloying compositions. In the past few years, there has been interest in a wider range of matrix materials that offer the potential for superior composite properties. These must be processed by solid-state processes and at sufficiently low temperatures to avoid undesired reactions between the tungsten and the matrix phase. These processes, in order of decreasing process temperature requirements, include hot-isostatic pressing (HIPing), hot extrusion, and dynamic compaction. The HIPing and hot extrusion processes have also been used to improve mechanical properties of conventional liquid-phase-sintered materials. Results of laboratory-scale investigations of solid-state consolidation of a variety of matrix materials, including titanium, hafnium, nickel aluminide, and steels are reviewed. The potential advantages and disadvantages of each of the possible alternative consolidation processes are identified. Postconsolidation processing to control microstructure and macrostructure is discussed, including novel methods of controlling microstructure alignment.

  3. Five factor model prototype matching scores: convergence within alternative methods.

    PubMed

    Samuel, Douglas B; Edmundson, Maryanne; Widiger, Thomas A

    2011-10-01

    The Five Factor Model of Personality (FFM) has been proposed as a potential alternative to the current DSM-IV-TR model, which conceptualizes personality disorders (PDs) as categorical constructs. While an extensive literature has pointed out the flaws of the diagnostic categories, they are quite familiar to clinicians and there may still be instances when identifying these constructs for clinical purposes, such as for rapidly communicating information about a patient, is warranted. From the perspective of the FFM, the PDs represent specific constellations of personality traits and research has demonstrated that the PDs can be recovered by assessing the degree to which an FFM profile matches the FFM description of a prototypic PD case. The current study builds upon that research by assessing the convergent and discriminant validity of prototype scores and DSM-IV PD measures using self-report, informant report, semi-structured interview, and clinician descriptions. The results suggest that the prototype matching scores are largely valid across these methods for all PDs, with perhaps the exception of obsessive-compulsive. These findings are related to previous research and the clinical implications of these findings are discussed. PMID:22023296

  4. Various methods for extracting forces on a moving plate using Time-Resolved Particle Image Velocimetry (TR-PIV)

    NASA Astrophysics Data System (ADS)

    Rival, D.; Schoenweitz, D.; Tropea, C.

    2009-11-01

    It is often very challenging or even impossible to measure the forces directly on swimming or flying animals. For this reason traditional control-volume methods are used to estimate the unsteady forces on the body in question. TR-PIV systems allow for the measurement of the full spatial and temporal velocity field in the control volume as well as along the bounding control surfaces. The corresponding pressure field can be integrated from the complete velocity-field data set. However, the measurement of the velocity field in the proximity of the body’s surface is at times cumbersome due to shadows and reflections. An alternate control-volume formulationfootnotetextJ. Z. Wu, Z.-L. Pan and X.-Y. Lu, ``Unsteady fluid-dynamic force solely in terms of control-surface integral,” Phys. of Fluids 17, 098102 (2005) eliminates the need for velocity measurements in the proximity of the body. This method has been tested and compared to the traditional control-volume technique for a generic pitching and plunging flat plate in a hover chamber. The advantages and disadvantages of these methods are discussed in the context of their measurement accuracy.

  5. An alternative method for determining GPS receiver phase biases

    NASA Astrophysics Data System (ADS)

    Kersten, Tobias; Schön, Steffen

    2015-04-01

    Precise Point Positioning (PPP) is used in a broad variety of applications to determine very economically high precision parameters for positioning, navigation and timing. In comparison to traditional differential approaches, PPP with undifferenced phase measurements is highly attractive, since the effort on the user side can be reduced to minimum, e.g. due to an unnecessary reference station. The quality of obtained position solutions is comparable to those obtained from a differential approach. One of the most important limiting factor is the long integration time to determine (float) ambiguities. Furthermore, it is critical to consider adequately all occurring error sources. In this context, receiver phase biases are one of the limiting factors and very complex to model. At least they are highly correlated with the ambiguities during the estimation process, (Laurichesse et al. 2009). This contribution presents an alternative method to estimate carrier phase biases of different GPS/GNSS receivers and signals w.r.t. a reference receiver. Receiver phase biases are estimated on a zero baseline and in combination with a very stable and precise clock (H-Maser) using single differences. The presented method will be discussed in detail. This includes a critical look to the estimability of bias values for several GPS/GNSS receivers as well as a discussion on the stability and universality of these bias values. Finally relative phase biases are quantified and it will be discussed how GPS/GNSS observation equations have to be extended, to take these bias values correctly into account. References: Laurichesse D., Mercier F., Berthias J.P., Broca P., Cerri L. (2009): Integer ambiguity resolution on undifferenced GPS phase measurements and its application to PPP and satellite precise orbit determination, In: NAVIGATION, Journal of the Institute of Navigation, Volume 56, Number 2, pages: 135 - 149

  6. Numerical Manifold Method for the Forced Vibration of Thin Plates during Bending

    PubMed Central

    Jun, Ding; Song, Chen; Wei-Bin, Wen; Shao-Ming, Luo; Xia, Huang

    2014-01-01

    A novel numerical manifold method was derived from the cubic B-spline basis function. The new interpolation function is characterized by high-order coordination at the boundary of a manifold element. The linear elastic-dynamic equation used to solve the bending vibration of thin plates was derived according to the principle of minimum instantaneous potential energy. The method for the initialization of the dynamic equation and its solution process were provided. Moreover, the analysis showed that the calculated stiffness matrix exhibited favorable performance. Numerical results showed that the generalized degrees of freedom were significantly fewer and that the calculation accuracy was higher for the manifold method than for the conventional finite element method. PMID:24883403

  7. Polarization characterization of PZT disks and of embedded PZT plates by thermal wave methods

    SciTech Connect

    Eydam, Agnes Suchaneck, Gunnar Gerlach, Gerald; Esslinger, Sophia; Schönecker, Andreas; Neumeister, Peter

    2014-11-05

    In this work, the thermal wave method was applied to characterize PZT disks and embedded PZT plates with regard to the polarization magnitude and spatial homogeneity. The samples were exposed to periodic heating by means of a laser beam and the pyroelectric response was determined. Thermal relaxation times (single time constants or distributions of time constants) describe the heat losses of the PZT samples to the environment. The resulting pyroelectric current spectrum was fitted to the superposition of thermal relaxation processes. The pyroelectric coefficient gives insight in the polarization distribution. For PZT disks, the polarization distribution in the surface region showed a characteristic decrease towards the electrodes.

  8. A simple method of chromium coating using a ferrotype plate for scanning electron microscopy.

    PubMed

    Mitsushima, A; Inoué, T

    1993-12-01

    A simple method of chromium coating was developed. A chromium ferrotype plate for drying photoprints was used as a target of a planar magnetron ion-sputter coater. As a result, a high quality chromium film was obtained on dried specimens at room temperature without cooling. The grain size, measuring 1-2 nm in diameter, was small enough for observations of ultrastructures such as F1 particles on the inner mitochondrial membrane. In routine studies under x 100,000, however, chromium coating was not recommended because of its low emission of secondary electrons. PMID:8176338

  9. Method of producing exfoliated graphite composite compositions for fuel cell flow field plates

    DOEpatents

    Zhamu, Aruna; Shi, Jinjun; Guo, Jiusheng; Jang, Bor Z

    2014-04-08

    A method of producing an electrically conductive composite composition, which is particularly useful for fuel cell bipolar plate applications. The method comprises: (a) providing a supply of expandable graphite powder; (b) providing a supply of a non-expandable powder component comprising a binder or matrix material; (c) blending the expandable graphite with the non-expandable powder component to form a powder mixture wherein the non-expandable powder component is in the amount of between 3% and 60% by weight based on the total weight of the powder mixture; (d) exposing the powder mixture to a temperature sufficient for exfoliating the expandable graphite to obtain a compressible mixture comprising expanded graphite worms and the non-expandable component; (e) compressing the compressible mixture at a pressure within the range of from about 5 psi to about 50,000 psi in predetermined directions into predetermined forms of cohered graphite composite compact; and (f) treating the so-formed cohered graphite composite to activate the binder or matrix material thereby promoting adhesion within the compact to produce the desired composite composition. Preferably, the non-expandable powder component further comprises an isotropy-promoting agent such as non-expandable graphite particles. Further preferably, step (e) comprises compressing the mixture in at least two directions. The method leads to composite plates with exceptionally high thickness-direction electrical conductivity.

  10. Fabrication of Alternating-Phase Fed Single-Layer Slotted Waveguide Arrays Using Plastic Materials with Metal-Plating

    NASA Astrophysics Data System (ADS)

    Zhang, Miao; Hirokawa, Jiro; Ando, Makoto

    Lightweight single-layer slotted waveguide array antennas are fabricated using plastic materials with metal-plating. A plastic material that has good heat-radiation properties is investigated. Three types of antennas are fabricated by milling, using ABS resin, heat-radiating plastic, and aluminum alloy. In measurements, all three types of antennas are confirmed to have almost the same VSWR and gain in the 25GHz frequency band.

  11. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.

    PubMed

    Petruševska, Marija; Urleb, Uroš; Peternel, Luka

    2013-11-01

    The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors. PMID:24056092

  12. Ice-Cap: a method for growing Arabidopsis and tomato plants in 96-well plates for high-throughput genotyping.

    PubMed

    Su, Shih-Heng; Clark, Katie A; Gibbs, Nicole M; Bush, Susan M; Krysan, Patrick J

    2011-01-01

    It is becoming common for plant scientists to develop projects that require the genotyping of large numbers of plants. The first step in any genotyping project is to collect a tissue sample from each individual plant. The traditional approach to this task is to sample plants one-at-a-time. If one wishes to genotype hundreds or thousands of individuals, however, using this strategy results in a significant bottleneck in the genotyping pipeline. The Ice-Cap method that we describe here provides a high-throughput solution to this challenge by allowing one scientist to collect tissue from several thousand seedlings in a single day (1,2). This level of throughput is made possible by the fact that tissue is harvested from plants 96-at-a-time, rather than one-at-a-time. The Ice-Cap method provides an integrated platform for performing seedling growth, tissue harvest, and DNA extraction. The basis for Ice-Cap is the growth of seedlings in a stacked pair of 96-well plates. The wells of the upper plate contain plugs of agar growth media on which individual seedlings germinate. The roots grow down through the agar media, exit the upper plate through a hole, and pass into a lower plate containing water. To harvest tissue for DNA extraction, the water in the lower plate containing root tissue is rapidly frozen while the seedlings in the upper plate remain at room temperature. The upper plate is then peeled away from the lower plate, yielding one plate with 96 root tissue samples frozen in ice and one plate with 96 viable seedlings. The technique is named "Ice-Cap" because it uses ice to capture the root tissue. The 96-well plate containing the seedlings can then wrapped in foil and transferred to low temperature. This process suspends further growth of the seedlings, but does not affect their viability. Once genotype analysis has been completed, seedlings with the desired genotype can be transferred from the 96-well plate to soil for further propagation. We have demonstrated

  13. [Alternative endourologic methods for treatment of urethral stricture].

    PubMed

    Niesel, T; Moore, R G; Hofmann, R; Kavoussi, L R

    1998-01-01

    Advances in endoscopic instrumentation and techniques offer new alternatives for safe and effective treatment of urethral strictures. Visual internal urethrotomy, the standard treatment modality, is associated with new scar formation with stricture recurrence. This experience has led to the investigation of alternative techniques which would avoid or ameliorate this result. This article reviews the current literature and discusses these newer approaches, including balloon dilatation, laser urethrotomy, endoscopic urethroplasty, "cut to the light" and "core through" procedures, and urethral wallstent implantation. PMID:9540185

  14. Vectorization and parallelization of the finite strip method for dynamic Mindlin plate problems

    NASA Technical Reports Server (NTRS)

    Chen, Hsin-Chu; He, Ai-Fang

    1993-01-01

    The finite strip method is a semi-analytical finite element process which allows for a discrete analysis of certain types of physical problems by discretizing the domain of the problem into finite strips. This method decomposes a single large problem into m smaller independent subproblems when m harmonic functions are employed, thus yielding natural parallelism at a very high level. In this paper we address vectorization and parallelization strategies for the dynamic analysis of simply-supported Mindlin plate bending problems and show how to prevent potential conflicts in memory access during the assemblage process. The vector and parallel implementations of this method and the performance results of a test problem under scalar, vector, and vector-concurrent execution modes on the Alliant FX/80 are also presented.

  15. HETEROTROPHIC PLATE COUNT BACTERIA IN POTABLE WATER: MONITORING METHODS AND APPLICATION

    EPA Science Inventory

    The heterotrophic plate count (HPC), formerly known as the standard plate count, is a useful tool for enumerating bacteria in potable water. his chapter briefly reviews the development of the heterotrophic bacterial plate count for use in water quality measurements in the United ...

  16. Is biofilm removal properly assessed? Comparison of different quantification methods in a 96-well plate system.

    PubMed

    Stiefel, Philipp; Rosenberg, Urs; Schneider, Jana; Mauerhofer, Stefan; Maniura-Weber, Katharina; Ren, Qun

    2016-05-01

    Various methods have been reported to quantify total biofilm or different components of biofilm; however, these methods are often confusedly used, leading to discrepancies and misleading results. In this study, different methods for quantification of biofilm, including those for total biomass, total amount of bacterial cells, viable cell number, and amount of extracellular polymeric substances, were systematically compared in microtiter plates. To evaluate which method is suitable for assessment of biofilm removal and for bacterial killing, biofilm samples were treated with various cleaners possessing removing and/or killing capacities. It was found that most of the methods tested in this study in general exhibited high reproducibility and repeatability. Crystal Violet staining was a simple but reliable method for total biomass quantification. Total bacteria cell numbers could be reliably quantified by the fluorescent DNA-binding dye Acridine Orange. Viable cells could be quantified by either an ATP-based assay or a proliferation assay. Both of these viability methods showed a broad detection range and led to precise measurement. For quantification of proteins in the biofilm, staining with fluorescein isothiocyanate was most suitable. Furthermore, it was revealed that a combination of different methods is required to determine if a cleaner kills or removes biofilm. PMID:26923144

  17. Method for sputtering with low frequency alternating current

    DOEpatents

    Timberlake, John R.

    1996-01-01

    Low frequency alternating current sputtering is provided by connecting a low frequency alternating current source to a high voltage transformer having outer taps and a center tap for stepping up the voltage of the alternating current. The center tap of the transformer is connected to a vacuum vessel containing argon or helium gas. Target electrodes, in close proximity to each other, and containing material with which the substrates will be coated, are connected to the outer taps of the transformer. With an applied potential, the gas will ionize and sputtering from the target electrodes onto the substrate will then result. The target electrodes can be copper or boron, and the substrate can be stainless steel, aluminum, or titanium. Copper coatings produced are used in place of nickel and/or copper striking.

  18. Method for sputtering with low frequency alternating current

    DOEpatents

    Timberlake, J.R.

    1996-04-30

    Low frequency alternating current sputtering is provided by connecting a low frequency alternating current source to a high voltage transformer having outer taps and a center tap for stepping up the voltage of the alternating current. The center tap of the transformer is connected to a vacuum vessel containing argon or helium gas. Target electrodes, in close proximity to each other, and containing material with which the substrates will be coated, are connected to the outer taps of the transformer. With an applied potential, the gas will ionize and sputtering from the target electrodes onto the substrate will then result. The target electrodes can be copper or boron, and the substrate can be stainless steel, aluminum, or titanium. Copper coatings produced are used in place of nickel and/or copper striking. 6 figs.

  19. A Novel Diagnosis Method for a Hall Plates-Based Rotary Encoder with a Magnetic Concentrator

    PubMed Central

    Meng, Bumin; Wang, Yaonan; Sun, Wei; Yuan, Xiaofang

    2014-01-01

    In the last few years, rotary encoders based on two-dimensional complementary metal oxide semiconductors (CMOS) Hall plates with a magnetic concentrator have been developed to measure contactless absolute angle. There are various error factors influencing the measuring accuracy, which are difficult to locate after the assembly of encoder. In this paper, a model-based rapid diagnosis method is presented. Based on an analysis of the error mechanism, an error model is built to compare minimum residual angle error and to quantify the error factors. Additionally, a modified particle swarm optimization (PSO) algorithm is used to reduce the calculated amount. The simulation and experimental results show that this diagnosis method is feasible to quantify the causes of the error and to reduce iteration significantly. PMID:25090417

  20. A novel diagnosis method for a Hall plates-based rotary encoder with a magnetic concentrator.

    PubMed

    Meng, Bumin; Wang, Yaonan; Sun, Wei; Yuan, Xiaofang

    2014-01-01

    In the last few years, rotary encoders based on two-dimensional complementary metal oxide semiconductors (CMOS) Hall plates with a magnetic concentrator have been developed to measure contactless absolute angle. There are various error factors influencing the measuring accuracy, which are difficult to locate after the assembly of encoder. In this paper, a model-based rapid diagnosis method is presented. Based on an analysis of the error mechanism, an error model is built to compare minimum residual angle error and to quantify the error factors. Additionally, a modified particle swarm optimization (PSO) algorithm is used to reduce the calculated amount. The simulation and experimental results show that this diagnosis method is feasible to quantify the causes of the error and to reduce iteration significantly. PMID:25090417

  1. A dual reciprocity boundary element solution method for the free vibration analysis of fluid-coupled Kirchhoff plates

    NASA Astrophysics Data System (ADS)

    Uğurlu, B.

    2015-03-01

    A boundary element solution method is proposed for linear vibration analysis of fluid-coupled thin plates. The method is based on replacing the associated biharmonic operator with two successive harmonic operators, leading to a coupled system of boundary integral equations with simpler properties: the fundamental solution has an elementary form, and complicated singularity removal techniques can be avoided. The fluid flow due to the plate motion is taken as a potential field, and its effect on the plate dynamics is incorporated into the analysis by invoking another boundary integral solution, described over the fluid-plate interface. The body terms in the plate boundary integral equations are considered by the dual reciprocity boundary element formulation. Three different radial basis functions are employed as interpolation functions, alone and augmented with polynomial and sine expansions, to represent the body terms. The performance of the method is investigated from several perspectives by adopting plates with different shapes and/or boundary conditions; excellent approximations are obtained in general: the convergence behavior is consistent, both dry and wet frequency parameters are predicted accurately, and the mode shapes are captured even with rough models. In some of the studied problems, however, deviated results are obtained for specific modes. Furthermore, it is observed that the performance of the method depends on the implemented DRM functions, and combining radial basis functions with global expansions does not yield noticeable improvements.

  2. Alternative modeling methods for plasma-based Rf ion sources

    NASA Astrophysics Data System (ADS)

    Veitzer, Seth A.; Kundrapu, Madhusudhan; Stoltz, Peter H.; Beckwith, Kristian R. C.

    2016-02-01

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H- source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H- ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models

  3. Alternative modeling methods for plasma-based Rf ion sources.

    PubMed

    Veitzer, Seth A; Kundrapu, Madhusudhan; Stoltz, Peter H; Beckwith, Kristian R C

    2016-02-01

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H(-) source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H(-) ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD

  4. Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods

    PubMed Central

    Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo

    2015-01-01

    The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r2 > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model. PMID:26539483

  5. Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods.

    PubMed

    Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo

    2015-01-01

    The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r(2) > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model. PMID:26539483

  6. A negative-norm least squares method for Reissner-Mindlin plates

    NASA Astrophysics Data System (ADS)

    Bramble, J. H.; Sun, T.

    1998-07-01

    In this paper a least squares method, using the minus one norm developed by Bramble, Lazarov, and Pasciak, is introduced to approximate the solution of the Reissner-Mindlin plate problem with small parameter t, the thickness of the plate. The reformulation of Brezzi and Fortin is employed to prevent locking. Taking advantage of the least squares approach, we use only continuous finite elements for all the unknowns. In particular, we may use continuous linear finite elements. The difficulty of satisfying the inf-sup condition is overcome by the introduction of a stabilization term into the least squares bilinear form, which is very cheap computationally. It is proved that the error of the discrete solution is optimal with respect to regularity and uniform with respect to the parameter t. Apart from the simplicity of the elements, the stability theorem gives a natural block diagonal preconditioner of the resulting least squares system. For each diagonal block, one only needs a preconditioner for a second order elliptic problem.

  7. Geospatial methods for monitoring alternative control technology sites

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Monitoring alternative feedlot runoff control technology effectiveness, especially vegetative treatment systems (VTS), is of interest to both cattlemen and regulatory agencies. Producers have constructed VTS in several mid-western states under an agreement with the Iowa Cattlemen Association and the...

  8. Alternatives in Medical Education: Non-Animal Methods.

    ERIC Educational Resources Information Center

    Carlson, Peggy, Ed.

    The technology explosion in medical education has led to the use of computer models, videotapes, interactive videos, and state-of-the-art simulators in medical training. This booklet describes alternatives to using animals in medical education. Although it is mainly intended to describe products applicable to medical school courses, high-quality,…

  9. Methods and formulas for calculating the strength of plate and shell constructions as used in airplane design

    NASA Technical Reports Server (NTRS)

    Heck, O S; Ebner, H

    1936-01-01

    This report is a compilation of previously published articles on formulas and methods of calculation for the determination of the strength and stability of plate and shell construction as employed in airplane design. In particular, it treats the problem of isotropic, orthotopic, and stiffened rectangular plates, thin curved panels, and circular cylinders under various loading conditions. The purpose of appending the pertinent literature references following the subjects discussed was to facilitate a comprehensive study of the treated problems.

  10. An Empirical Method for Fast Prediction of Rarefied Flow Field around a Vertical Plate

    NASA Astrophysics Data System (ADS)

    He, Tao; Wang, Jiang-Feng

    2016-06-01

    Numerical study is conducted to investigate the effects of free-stream Knudsen (Kn) number on rarefied flow field around a vertical plate employing an unstructured DSMC method, and an empirical method for fast prediction of flow-field structure at different Kn numbers in a given inflow velocity is proposed. First, the flow at a velocity 7500m/s is simulated using a perfect-gas model with free-stream Kn changing from 0.035 to 13.36. The flow-field characteristics in these cases with varying Kn numbers are analyzed and a linear-expansion phenomenon as a function of the square of Kn is discovered. An empirical method is proposed for fast flow-field prediction at different Kn based on the least-square-fitting method. Further, the effects of chemical reactions on flow field are investigated to verify the applicability of the empirical method in the real gas conditions. Three of the cases in perfect-gas flow are simulated again by introducing five-species air chemical module. The flow properties with and without chemical reactions are compared. In the end, the variation of chemical-reaction flow field as a function of Kn is analyzed and it is shown that the empirical method are also suitable when considering chemical reactions.

  11. Experimental comparison and validation of hot-ball method with guarded hot plate method on polyurethane foams

    NASA Astrophysics Data System (ADS)

    Hudec, Ján; Glorieux, Christ; Dieška, Peter; Kubičár, Ľudovít

    2016-07-01

    The Hot-ball method is an innovative transient method for measuring thermophysical properties. The principle is based on heating of a small ball, incorporated in measured medium, by constant heating power and simultaneous measuring of the ball's temperature response since the heating was initiated. The shape of the temperature response depends on thermophysical properties of the medium, where the sensor is placed. This method is patented by Institute of Physics, SAS, where the method and sensors based on this method are being developed. At the beginning of the development of sensors for this method we were oriented on monitoring applications, where relative precision is much more important than accuracy. Meanwhile, the quality of sensors was improved good enough to be used for a new application - absolute measuring of thermophysical parameters of low thermally conductive materials. This paper describes experimental verification and validation of measurement by hot-ball method. Thanks to cooperation with Laboratory of Soft Matter and Biophysics of Catholic University of Leuven in Belgium, established Guarded Hot Plate method was used as a reference. Details about measuring setups, description of the experiments and results of the comparison are presented.

  12. Fourier series methods for cracks in polygonal plates and shells of revolution

    NASA Astrophysics Data System (ADS)

    Kwok, Frankie Man Wai

    The objective of the study is to develop efficient numerical methods of solving fracture mechanics problems. In addition to computational efficiency, these methods must require minimal user set-up times. A final criterion is the avoidance of special crack-tip elements to capture the singular behavior. The first part of the study focuses on cracked polygonal plates under anti-plane loading. The basis of this work is the Fourier series method, which transforms a problem with a complicated geometry into a summation of half-plane problems. Through this method, the problem takes the form of a matrix equation, solution of which gives the out-of-plane displacement at any point in the plate. With this solution, the J-integral is found to be an accurate and efficient method of obtaining the stress intensity factor. A number of examples are given to illustrate the versatility of this Fourier series method. The second part of the study continues onward to shells of revolution with circumferential through cracks. The shell problem is formulated as a state vector equation. With an asymptotic-numeric procedure, the edge stiffness matrix for each Fourier circumferential harmonic is obtained. The next step involves constructing the expansion and contraction matrices, which relate the Fourier harmonics of the crack domain to those of the whole circumferential domain. By combining the edge stiffness matrices with the expansion and contraction matrices, a matrix equation is formed. Solution of this equation yields the crack-face displacements satisfying the traction free condition in the crack domain. Numerous examples are presented, which include cracks at the middle sections or fixed ends of cylindrical shells under tensile, bending, or torsional loads. With the above methods, various fracture mechanics parameters can be obtained. These include the crack driving force, the stress intensity factor, the crack opening displacement and area. For the anti-plane problem, stress intensity

  13. 48 CFR 6302.30 - Alternative dispute resolution methods (Rule 30).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION BOARD OF CONTRACT APPEALS RULES OF PROCEDURE 6302.30 Alternative dispute resolution methods (Rule... Alternative Dispute Resolution (ADR): Settlement Judges and Mini-Trials. These procedures are designed to... 48 Federal Acquisition Regulations System 7 2011-10-01 2011-10-01 false Alternative...

  14. 48 CFR 6302.30 - Alternative dispute resolution methods (Rule 30).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION BOARD OF CONTRACT APPEALS RULES OF PROCEDURE 6302.30 Alternative dispute resolution methods (Rule... Alternative Dispute Resolution (ADR): Settlement Judges and Mini-Trials. These procedures are designed to... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Alternative...

  15. Alternative Methods for Field Corrections in Helical Solenoids

    SciTech Connect

    Lopes, M. L.; Krave, S. T.; Tompkins, J. C.; Yonehara, K.; Flanagan, G.; Kahn, S. A.; Melconian, K.

    2015-05-01

    Helical cooling channels have been proposed for highly efficient 6D muon cooling. Helical solenoids produce solenoidal, helical dipole, and helical gradient field components. Previous studies explored the geometric tunability limits on these main field components. In this paper we present two alternative correction schemes, tilting the solenoids and the addition of helical lines, to reduce the required strength of the anti-solenoid and add an additional tuning knob.

  16. Single Transducer Ultrasonic Imaging Method that Eliminates the Effect of Plate Thickness Variation in the Image

    NASA Technical Reports Server (NTRS)

    Roth, Don J.

    1996-01-01

    This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.

  17. Direct Evaluation of the Figure of Merit of Thermoelectric Devices by Guarded Hot Plate Method

    NASA Astrophysics Data System (ADS)

    Kwon, Su Yong; Kim, Yong-Gyoo; Lee, Sanghyun; Kim, Jong Chul

    2013-03-01

    An apparatus for the evaluation of the figure of merit (ZT) of thermoelectric devices has been developed and ZT values have been estimated for a thermoelectric device. The most challenging problem in ZT value evaluation in this apparatus was measuring the thermal conductivity of the devices precisely. We have solved the problem by introducing a primary thermal conductivity measurement technique, a guarded hot plate method, which makes it possible to obtain directly and simultaneously four physical parameters related to the ZT, namely the thermal conductivity, electrical conductivity, Seebeck coefficient, and absolute temperature. The ZT evaluation was performed by a single scan of the temperature difference between the top and bottom surfaces of the device. We also addressed the thermoelectric properties and the power generation efficiency of a commercial thermoelectric device. The evaluation uncertainty of the ZT value was assessed to secure reliability of the apparatus and was found to be 3.59%.

  18. Piezoelectrically forced vibrations of electroded doubly rotated quartz plates by state space method

    NASA Technical Reports Server (NTRS)

    Chander, R.

    1990-01-01

    The purpose of this investigation is to develop an analytical method to study the vibration characteristics of piezoelectrically forced quartz plates. The procedure can be summarized as follows. The three dimensional governing equations of piezoelectricity, the constitutive equations and the strain-displacement relationships are used in deriving the final equations. For this purpose, a state vector consisting of stresses and displacements are chosen and the above equations are manipulated to obtain the projection of the derivative of the state vector with respect to the thickness coordinate on to the state vector itself. The solution to the state vector at any plane is then easily obtained in a closed form in terms of the state vector quantities at a reference plane. To simplify the analysis, simple thickness mode and plane strain approximations are used.

  19. A study of turbulent flow between parallel plates by a statistical method

    NASA Technical Reports Server (NTRS)

    Srinivasan, R.; Giddens, D. P.; Bangert, L. H.; Wu, J. C.

    1976-01-01

    Turbulent Couette flow between parallel plates was studied from a statistical mechanics approach utilizing a model equation, similar to the Boltzmann equation of kinetic theory, which was proposed by Lundgren from the velocity distribution of fluid elements. Solutions to this equation are obtained numerically, employing the discrete ordinate method and finite differences. Two types of boundary conditions on the distribution function are considered, and the results of the calculations are compared to available experimental data. The research establishes that Lundgren's equation provides a very good description of turbulence for the flow situation considered and that it offers an analytical tool for further study of more complex turbulent flows. The present work also indicates that modelling of the boundary conditions is an area where further study is required.

  20. A New XRD Method to Quantify Plate and Lath Martensites of Hardened Medium-Carbon Steel

    NASA Astrophysics Data System (ADS)

    Luo, Quanshun

    2016-06-01

    This paper introduces a new technique to separately measure the volume fraction and tetragonal ratio of co-existing lath and plate martensites in ultrahigh strength steel, and to calculate their different carbon contents. First, the two martensites are assumed to have body-centered tetragonal lattice structures of different tetragonal ratios. X-ray diffraction is then applied to obtain the overlapping {200} diffraction peak, which is subsequently separated as four sub-peaks using a self-made multiple Gaussian peak-fitting method to allow the measurement of the individual lattice parameters c and a. Finally, a modified equation is applied to calculate the carbon contents from the obtained tetragonal ratios. The new technique is then applied to investigate the effect of subsequent tempering on the decarbonization of the as-quenched martensites.

  1. A New XRD Method to Quantify Plate and Lath Martensites of Hardened Medium-Carbon Steel

    NASA Astrophysics Data System (ADS)

    Luo, Quanshun

    2016-04-01

    This paper introduces a new technique to separately measure the volume fraction and tetragonal ratio of co-existing lath and plate martensites in ultrahigh strength steel, and to calculate their different carbon contents. First, the two martensites are assumed to have body-centered tetragonal lattice structures of different tetragonal ratios. X-ray diffraction is then applied to obtain the overlapping {200} diffraction peak, which is subsequently separated as four sub-peaks using a self-made multiple Gaussian peak-fitting method to allow the measurement of the individual lattice parameters c and a. Finally, a modified equation is applied to calculate the carbon contents from the obtained tetragonal ratios. The new technique is then applied to investigate the effect of subsequent tempering on the decarbonization of the as-quenched martensites.

  2. A semi-analytical method to evaluate the dynamic response of functionally graded plates subjected to underwater shock

    NASA Astrophysics Data System (ADS)

    Liang, Xu; Wang, Zhenyu; Wang, Lizhong; Izzuddin, Bassam A.; Liu, Guohua

    2015-02-01

    Functionally graded (FG) plates are of current interest and are widely used in a variety of applications including deep sea exploration and naval/marine and coastal engineering, despite the fact that there has, to date, been little research undertaken on the subject. In order to remedy the situation, an analytical method to investigate the elastic dynamic responses of FG plates to underwater shock is proposed here, their material properties varying by the same exponential law along the thickness direction. Taylor's one dimensional fluid solid interaction (FSI) model is extended to fit a three dimensional model suitable for FG plates. The extended FSI model and Laplace transform are integrated into the state space method, with the transient solution in the time domain being obtained by using the numerical inversion of the Laplace transform. The solutions of the total forces acting throughout the front and back faces in the time domain are derived for the first time. The present method is validated by comparing it with the results of other methods and experiments found in the relevant literature. The influence of the boundary conditions at the backside of the plate and FG parameters on front and back side pressures, cavitations, displacements, stresses and total forces acting throughout the faces are then investigated, with the time progression of the cavitation areas of air-backed plates and water-backed plates being investigated in detail. The method proposed in this paper may prove useful for the future three-dimensional assessment of the response of FG structures when FSI effects are taken into consideration. It is hoped that the results will lead to a full understanding of the mechanism of the interaction between fluid and an FG plate, and that they can be used as benchmark solutions in further research.

  3. Variable-node plate and shell elements with assumed natural strain and smoothed integration methods for nonmatching meshes

    NASA Astrophysics Data System (ADS)

    Sohn, Dongwoo; Im, Seyoung

    2013-06-01

    In this paper, novel finite elements that include an arbitrary number of additional nodes on each edge of a quadrilateral element are proposed to achieve compatible connection of neighboring nonmatching meshes in plate and shell analyses. The elements, termed variable-node plate elements, are based on two-dimensional variable-node elements with point interpolation and on the Mindlin-Reissner plate theory. Subsequently the flat shell elements, termed variable-node shell elements, are formulated by further extending the plate elements. To eliminate a transverse shear locking phenomenon, the assumed natural strain method is used for plate and shell analyses. Since the variable-node plate and shell elements allow an arbitrary number of additional nodes and overcome locking problems, they make it possible to connect two nonmatching meshes and to provide accurate solutions in local mesh refinement. In addition, the curvature and strain smoothing methods through smoothed integration are adopted to improve the element performance. Several numerical examples are presented to demonstrate the effectiveness of the elements in terms of the accuracy and efficiency of the analyses.

  4. 76 FR 23323 - Meeting of the Scientific Advisory Committee on Alternative Toxicological Methods (SACATM)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-26

    ... HUMAN SERVICES Meeting of the Scientific Advisory Committee on Alternative Toxicological Methods (SACATM... Activation Test Method for Endocrine Disruptor Chemical Screening Federal Agency Research, Development... the scientific validation and regulatory acceptance of toxicological and safety testing methods...

  5. 49 CFR Appendix B to Part 178 - Alternative Leakproofness Test Methods

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Alternative Leakproofness Test Methods B Appendix... FOR PACKAGINGS Pt. 178, App. B Appendix B to Part 178—Alternative Leakproofness Test Methods In addition to the method prescribed in § 178.604 of this subchapter, the following leakproofness test...

  6. An Alternative Field Method for Screening Soybean Genotypes for Resistance to Heterodera glycines

    PubMed Central

    Arantes, N. E.; Mauro, A. O.; Tihohood, D.

    1998-01-01

    The soybean cyst nematode (Heterodera glycines) has become an increasingly severe problem in soybean production areas in Brazil. The development and use of resistant cultivars is the most efficient method of minimizing losses due to this pathogen. Our objective was to test the efficiency of an alternative method for screening soybean genotypes for resistance to H. glycines in field plots. The alternative method was compared to the standard method of sowing the test genotypes in fields found to be infested during the previous crop season. In the alternative method, the test genotypes are sown in the furrow following the uprooting of 45-day-old infected plants. The alternative method resulted in twice the cyst population and fewer escapes, and more consistent results than the standard method. The major advantage of the alternative method is that it permits screening in a more homogeneous distribution of H. glycines in the soil. PMID:19274244

  7. Enumeration of total coliforms and E. coli in foods by the SimPlate coliform and E. coli color indicator method and conventional culture methods: collaborative study.

    PubMed

    Feldsine, Philip T; Lienau, Andrew H; Roa, Nerie H; Green, Shannon T

    2005-01-01

    The relative effectiveness of the SimPlate Coliform and E. coli Color Indicator (CEc-CI) method was compared to the AOAC 3-tube Most Probable Number (MPN) methods for enumerating and confirming coliforms and Escherichia coli in foods (966.23 and 966.24). In this study, test portions were prepared and analyzed according to the conditions stated in both the AOAC methods and SimPlate directions for use. Six food types were artificially contaminated with coliform bacteria and E. coli: frozen burritos, frozen broccoli, fluid pasteurized milk, whole almond nut meats, cheese, and powdered cake mix. Method comparisons were conducted. Overall, the SimPlate method demonstrated <0.3 log difference for total coliform and E. coli counts compared to the AOAC reference methods for the majority of food types and levels analyzed. In all cases, the repeatability and reproducibility of the SimPlate CEc-CI method were not different from those of the reference methods and in certain cases, were statistically better than those of the AOAC 3-tube MPN methods. These results indicate that the SimPlate CEc-CI method and the reference culture methods are comparable for enumeration of both total coliforms and E. coli in foods. PMID:16385981

  8. Quasi-simultaneous interaction method for solving 2D boundary layer flows over plates and airfoils

    NASA Astrophysics Data System (ADS)

    Bijleveld, H. A.; Veldman, A. E. P.

    2012-11-01

    This paper studies unsteady 2D boundary layer flows over dented plates and a NACA 0012 airfoil. An inviscid flow is assumed to exist outside the boundary layer and is solved iteratively with the boundary layer flow together with the interaction method until a matching solution is achieved. Hereto a quasi-simultaneous interaction method is applied, in which the integral boundary layer equations are solved together with an interaction-law equation. The interaction-law equation is an approximation of the external flow and based on thin-airfoil theory. It is an algebraic relation between the velocity and displacement thickness. The interaction-law equation ensures that the eigenvalues of the system of equations do not have a sign change and that no singularities occur. Three numerical schemes are used to solve the boundary layer flow with the interaction method. These are: a standard scheme, a splitting method and a characteristics solver. All schemes use a finite difference discretization. The three schemes yield comparable results for the simulations carried out. The standard scheme is deviating most from the splitting and characteristics solvers. The results show that the eigenvalues remain positive, even in separation. As expected, the addition of the interaction-law equation prevents a sign change of the eigenvalues. The quasi-simultaneous interaction scheme is applicable to the three numerical schemes tested.

  9. Methods and Piezoelectric Imbedded Sensors for Damage Detection in Composite Plates Under Ambient and Cryogenic Conditions

    NASA Technical Reports Server (NTRS)

    Engberg, Robert; Ooi, Teng K.

    2004-01-01

    New methods for structural health monitoring are being assessed, especially in high-performance, extreme environment, safety-critical applications. One such application is for composite cryogenic fuel tanks. The work presented here attempts to characterize and investigate the feasibility of using imbedded piezoelectric sensors to detect cracks and delaminations under cryogenic and ambient conditions. A variety of damage detection methods and different Sensors are employed in the different composite plate samples to aid in determining an optimal algorithm, sensor placement strategy, and type of imbedded sensor to use. Variations of frequency, impedance measurements, and pulse echoing techniques of the sensors are employed and compared. Statistical and analytic techniques are then used to determine which method is most desirable for a specific type of damage. These results are furthermore compared with previous work using externally mounted sensors. Results and optimized methods from this work can then be incorporated into a larger composite structure to validate and assess its structural health. This could prove to be important in the development and qualification of any 2" generation reusable launch vehicle using composites as a structural element.

  10. Robust scatter correction method for cone-beam CT using an interlacing-slit plate

    NASA Astrophysics Data System (ADS)

    Huang, Kui-Dong; Xu, Zhe; Zhang, Ding-Hua; Zhang, Hua; Shi, Wen-Long

    2016-06-01

    Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter correction method for CBCT using an interlacing-slit plate (ISP) is carried out for convenient practice. Firstly, a Gaussian filtering method is proposed to compensate the missing data of the inner scatter image, and simultaneously avoid too-large values of calculated inner scatter and smooth the inner scatter field. Secondly, an interlacing-slit scan without detector gain correction is carried out to enhance the practicality and convenience of the scatter correction method. Finally, a denoising step for scatter-corrected projection images is added in the process flow to control the noise amplification The experimental results show that the improved method can not only make the scatter correction more robust and convenient, but also achieve a good quality of scatter-corrected slice images. Supported by National Science and Technology Major Project of the Ministry of Industry and Information Technology of China (2012ZX04007021), Aeronautical Science Fund of China (2014ZE53059), and Fundamental Research Funds for Central Universities of China (3102014KYJD022)

  11. Free vibration analysis of plate assemblies using the dynamic stiffness method based on the higher order shear deformation theory

    NASA Astrophysics Data System (ADS)

    Kolarevic, Nevenka; Marjanović, Miroslav; Nefovska-Danilovic, Marija; Petronijevic, Mira

    2016-03-01

    This paper deals with the free vibration analysis of isotropic plate assemblies using the dynamic stiffness method (DSM) based on the Reddy's higher-order shear deformation theory (HSDT). Using the proposed method, the isotropic rectangular plate assemblies of non-uniform thickness and material properties can be analyzed. The proposed model does not have any restrictions regarding the boundary conditions or the frequency limitations. It enables free vibration analysis of both thin and thick plates, making it advantageous in comparison with the conventional finite element method (FEM) regarding the computational cost and the accuracy of the results. Three coupled Euler-Lagrange equations of motion based on the HSDT have been transformed into two uncoupled equations of motion introducing a boundary layer function. The dynamic stiffness matrix for a completely free rectangular plate element has been derived using the superposition and the projection method. The proposed numerical model has been applied in the free vibration analysis of rectangular plate assemblies. Along with the convergence study, the results for natural frequencies have been validated against the existing data from the literature, the previous results from the authors as well as the results obtained by using the finite element software Abaqus. Excellent agreement has been obtained. Finally, a variety of new results is provided as a benchmark for future investigations.

  12. An Alternative Empirical Formula for Positive Corona Discharge I-V Characteristics in Point-to-Plate Electrode Geometry

    NASA Astrophysics Data System (ADS)

    A. Azooz, A.; Sabah, I. Waysi

    2014-03-01

    Experimental data are presented for a study on the dependence of the I-V characteristics of the corona discharge on pressure and electrode spacing using point-to-plane electrode configuration. These experimental data are obtained by a fast, automatic computer data-acquisition system. The data are used to suggest an alternative dimensionally self-consistent empirical equation for the parameterization of the I-V curves. The formula eliminates the need for any prior assumptions concerning the inception voltage, as is customary in this type of work.

  13. Are allogenic or xenogenic screws and plates a reasonable alternative to alloplastic material for osteosynthesis--a histomorphological analysis in a dynamic system.

    PubMed

    Jacobsen, C; Obwegeser, J A

    2010-12-01

    Despite invention of titanium and resorbable screws and plates, still, one of the main challenges in bone fixation is the search for an ideal osteosynthetic material. Biomechanical properties, biocompatibility, and also cost effectiveness and clinical practicability are factors for the selection of a particular material. A promising alternative seems to be screws and plates made of bone. Recently, xenogenic bone pins and screws have been invented for use in joint surgery. In this study, screws made of allogenic sheep and xenogenic human bone were analyzed in a vital and dynamic sheep-model and compared to conventional titanium screws over a standard period of bone healing of 56 days with a constant applied extrusion force. Biomechanical analysis and histomorphological evaluation were performed. After 56 days of insertion xenogenic screws made of human bone showed significantly larger distance of extrusion of on average 173.8 μm compared to allogenic screws made of sheep bone of on average 27.8 and 29.95 μm of the titanium control group. Severe resorption processes with connective tissue interposition were found in the histomorphological analysis of the xenogenic screws in contrast to new bone formation and centripetal vascularization of the allogenic bone screw, as well as in processes of incorporation of the titanium control group. The study showed allogenic cortical bone screws as a substantial alternative to titanium screws with good biomechanical properties. In contrast to other reports a different result was shown for the xenogenic bone screws. They showed insufficient holding strength with confirmative histomorphological signs of degradation and insufficient osseointegration. Before common clinical use of xenogenic osteosynthetic material, further evaluation should be performed. PMID:20813368

  14. AN INTERCOMPARISON CF THE INTEGRATING PLATE AND THE LASER TRANSMISSION METHODS FOR DETERMINATION OF AEROSOL ABSORPTION COEFFICIENTS

    SciTech Connect

    Sadler, M.; Charlson, R.J.; Rosen, H.; Novakov, T.

    1980-07-01

    The absorption coefficients determined by the integrating plate method and the laser transmission method are found to be comparable and highly correlated. Furthermore, a high correlation is found between these absorption coefficients and the carbon content of the aerosol in urbanized regions.

  15. An Alternative Method To Measure MIS Faculty Teaching Performance.

    ERIC Educational Resources Information Center

    Simon, Judith C.; Soliman, Khalid S.

    2003-01-01

    Developed a method of measuring a professor's performance using student evaluations in the field of information systems by measuring differences in student perceptions and knowledge. Findings for 328 students show the usefulness of this method in assessing teacher performance. (SLD)

  16. Influence of the ARC patterning method and annealing on the contact adhesion of Ni/Cu-plated solar cells

    NASA Astrophysics Data System (ADS)

    Baik, Jong Wook; Lee, Sang Hee; Lee, Doo Won; Lee, Soo Hong

    2016-05-01

    Ni/Cu two-step plating is a promising metallization technique because low contact resistance and improved contact adhesion can be achieved after the Ni annealing process. Also, narrow fingers, which are required for high-efficiency solar cells, can be formed by plating. However, the reliability of contact adhesion is still considered one obstacle to industrializing solar cells with plated metal contacts. In this experiment, the influence of ARC opening methods on plated contact adhesion was investigated because the roughnesses of the Si surfaces produced by using pico-second laser ablation and photolithography may be different. Also, the annealing process was conducted before and after plating Cu/Ag metal stacks. The sequence of the annealing can be significant for efficient production because plating is a wet process while annealing is a dry process. The contact adhesion was measured by using a peel-off test. The test was conducted on a 1.5-mm-wide by a 60 ~ 70- mm-long bus bar area. A 3.2-N/mm adhesion force was recorded as a highest average value along the bus bar.

  17. [Effective method for decontaminating radioactive X-ray detectors (imaging plates)].

    PubMed

    Nishihara, Sadamitsu; Hayashi, Hiroaki

    2011-01-01

    Several hospitals have been observing black spots in medical images, and the radioisotopes (RIs) that cause the spots needs to be removed from the X-ray receptors. Our purpose is to show a flowchart for finding out under which conditions an imaging plate (IP) and other parts (for example, the cassette) are contaminated by RIs and to propose an effective method to remove them. The procedure follows. (1) Is RI activity low? (2) Are the surfaces of other parts contaminated? (3) Is the surface of the IP contaminated? (4) Are the insides of the other parts contaminated? To remove the adhered RIs, we applied a wipe test method using a wet type of chemical wiper. A certain hospital that observed black spots experimented with this method. As a result, the contaminated condition of the X-ray receptor was identified. In addition, we were able to remove the RIs from the IP. Therefore, our procedure is very effective for decontaminating adhered RIs from receptors. PMID:21869545

  18. An Alternative Method to the Classical Partial Fraction Decomposition

    ERIC Educational Resources Information Center

    Cherif, Chokri

    2007-01-01

    PreCalculus students can use the Completing the Square Method to solve quadratic equations without the need to memorize the quadratic formula since this method naturally leads them to that formula. Calculus students, when studying integration, use various standard methods to compute integrals depending on the type of function to be integrated.…

  19. Alternative and efficient extraction methods for marine-derived compounds.

    PubMed

    Grosso, Clara; Valentão, Patrícia; Ferreres, Federico; Andrade, Paula B

    2015-05-01

    Marine ecosystems cover more than 70% of the globe's surface. These habitats are occupied by a great diversity of marine organisms that produce highly structural diverse metabolites as a defense mechanism. In the last decades, these metabolites have been extracted and isolated in order to test them in different bioassays and assess their potential to fight human diseases. Since traditional extraction techniques are both solvent- and time-consuming, this review emphasizes alternative extraction techniques, such as supercritical fluid extraction, pressurized solvent extraction, microwave-assisted extraction, ultrasound-assisted extraction, pulsed electric field-assisted extraction, enzyme-assisted extraction, and extraction with switchable solvents and ionic liquids, applied in the search for marine compounds. Only studies published in the 21st century are considered. PMID:26006714

  20. An alternating minimization method for blind deconvolution from Poisson data

    NASA Astrophysics Data System (ADS)

    Prato, Marco; La Camera, Andrea; Bonettini, Silvia

    2014-10-01

    Blind deconvolution is a particularly challenging inverse problem since information on both the desired target and the acquisition system have to be inferred from the measured data. When the collected data are affected by Poisson noise, this problem is typically addressed by the minimization of the Kullback-Leibler divergence, in which the unknowns are sought in particular feasible sets depending on the a priori information provided by the specific application. If these sets are separated, then the resulting constrained minimization problem can be addressed with an inexact alternating strategy. In this paper we apply this optimization tool to the problem of reconstructing astronomical images from adaptive optics systems, and we show that the proposed approach succeeds in providing very good results in the blind deconvolution of nondense stellar clusters.

  1. Alternative and Efficient Extraction Methods for Marine-Derived Compounds

    PubMed Central

    Grosso, Clara; Valentão, Patrícia; Ferreres, Federico; Andrade, Paula B.

    2015-01-01

    Marine ecosystems cover more than 70% of the globe’s surface. These habitats are occupied by a great diversity of marine organisms that produce highly structural diverse metabolites as a defense mechanism. In the last decades, these metabolites have been extracted and isolated in order to test them in different bioassays and assess their potential to fight human diseases. Since traditional extraction techniques are both solvent- and time-consuming, this review emphasizes alternative extraction techniques, such as supercritical fluid extraction, pressurized solvent extraction, microwave-assisted extraction, ultrasound-assisted extraction, pulsed electric field-assisted extraction, enzyme-assisted extraction, and extraction with switchable solvents and ionic liquids, applied in the search for marine compounds. Only studies published in the 21st century are considered. PMID:26006714

  2. Enumeration of total yeasts and molds in foods by the SimPlate Yeast and Mold-Color Indicator method and conventional culture methods: collaborative study.

    PubMed

    Feldsine, Philip T; Lienau, Andrew H; Leung, Stephanie C; Mui, Linda A

    2003-01-01

    The relative effectiveness of the SimPlate Yeast and Mold-Color Indicator method (Y&M-CI) was compared to the U.S. Food and Drug Administration's (FDA) Bacteriological Analytical Manual (BAM) method and the proposed International Organization for Standardization (ISO) method, ISO/CD 21527, for enumerating yeasts and molds in foods. Test portions were prepared and incubated according to the conditions stated in both the BAM and ISO methods. Six food types were analyzed: frozen corn dogs, nut meats, frozen fruits, cake mix, cereal, and fresh cheese. Nut meats, frozen fruits, and fresh cheese were naturally contaminated. All other foods were artificially contaminated with either a yeast or mold. Seventeen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery between the SimPlate method and the 2 corresponding reference methods. Moreover, mean log counts between the 2 reference methods were also very similar. The repeatability (Sr) and reproducibility (SR) standard deviations were comparable between the 3 method comparisons. These results indicate that the BAM method and the SimPlate method are equivalent for enumerating yeast and mold populations in foods. Similarly, the SimPlate method is comparable to the proposed ISO method when test portions are prepared and incubated as defined in the proposed ISO method. PMID:12723916

  3. Methods for testing Zernike phase plates and a report on silicon-based phase plates with reduced charging and improved ageing characteristics

    PubMed Central

    Marko, Michael; Meng, Xing; Hsieh, Chyongere; Roussie, James; Striemer, Christopher

    2013-01-01

    Imaging with Zernike phase plates is increasingly being used in cryo-TEM tomography and cryo-EM single-particle applications. However, rapid ageing of the phase plates, together with the cost and effort in producing them, present serious obstacles to widespread adoption. We are experimenting with phase plates based on silicon chips that have thin windows; such phase plates could be mass-produced and made available at moderate cost. The windows are coated with conductive layers to reduce charging, and this considerably extends the useful life of the phase plates compared to traditional pure-carbon phase plates. However, a compromise must be reached between robustness and transmission through the phase-plate film. Details are given on testing phase-plate performance by means of imaging an amorphous thin film and evaluating the power spectra of the images. PMID:23994351

  4. Alternative Methods of the Thermospheric Atomic Oxygen Density Determination

    NASA Technical Reports Server (NTRS)

    Bennett. Adam C.; Omidvar, Kazem; Einaudi, Franco (Technical Monitor)

    2000-01-01

    Atomic oxygen density in the upper thermosphere (approximately 300 km) can be calculated using ground based incoherent scatter radar and Fabry-Perot interferometer measurements. Burnside et al. [1991] was the first to try this method, but Buonsanto et al. provided an extensive treatment of the method in 1997. This paper further examines the method using 46 nights of data collected over six years and the latest information on the oxygen collision frequency. The method is compared with the MSIS-86 atomic oxygen prediction values, which are based upon in situ rocket born and satellite measurements from the 70's to the mid-80's In general, the method supports the MSIS-86 model, but indicates several areas of discrepancy. Furthermore, no direct correlation is found between the geomagnetic conditions and the difference between the method and MSIS-86 predictions.

  5. Alternative Method for the Thermospheric Atomic Oxygen Density Determination

    NASA Technical Reports Server (NTRS)

    Bennett, A. C.; Omidvar, K.; Atlas, Robert (Technical Monitor)

    2001-01-01

    Atomic oxygen density in the upper thermosphere (approximately 300 km) can be calculated using ground based incoherent scatter radar and Fabry-Perot interferometer measurements. Burnside et al. was the first to try this method, but Buonsanto et al. provided an extensive treatment of the method in 1997. This paper further examines the method using 46 nights of data collected over six years and the latest information on the oxygen collision frequency. The method is compared with the MSIS (Mass Spectrometer Incoherent Scatter)-86 atomic oxygen prediction values, which are based upon in situ rocket born and satellite measurements from the 70s to the mid-80s. In general, the method supports the MSIS-86 model, but indicates several areas of discrepancy. Furthermore, no direct correlation is found between the geomagnetic conditions and the difference between the method and MSIS-86 predictions.

  6. Multidimensional Programming Methods for Energy Facility Siting: Alternative Approaches

    NASA Technical Reports Server (NTRS)

    Solomon, B. D.; Haynes, K. E.

    1982-01-01

    The use of multidimensional optimization methods in solving power plant siting problems, which are characterized by several conflicting, noncommensurable objectives is addressed. After a discussion of data requirements and exclusionary site screening methods for bounding the decision space, classes of multiobjective and goal programming models are discussed in the context of finite site selection. Advantages and limitations of these approaches are highlighted and the linkage of multidimensional methods with the subjective, behavioral components of the power plant siting process is emphasized.

  7. 46 CFR 50.20-30 - Alternative materials or methods of construction.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Alternative materials or methods of construction. 50.20-30 Section 50.20-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Plan Submittal and Approval § 50.20-30 Alternative materials or methods of construction. (a) When new or...

  8. 46 CFR 50.20-30 - Alternative materials or methods of construction.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Alternative materials or methods of construction. 50.20-30 Section 50.20-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Plan Submittal and Approval § 50.20-30 Alternative materials or methods of construction. (a) When new or...

  9. 30 CFR 250.1504 - May I use alternative training methods?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and Production Safety Training § 250.1504 May I use alternative training methods? You may use... 30 Mineral Resources 2 2012-07-01 2012-07-01 false May I use alternative training methods? 250.1504 Section 250.1504 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT...

  10. 30 CFR 250.1504 - May I use alternative training methods?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and Production Safety Training § 250.1504 May I use alternative training methods? You may use... 30 Mineral Resources 2 2014-07-01 2014-07-01 false May I use alternative training methods? 250.1504 Section 250.1504 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT...

  11. 30 CFR 250.1504 - May I use alternative training methods?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and Production Safety Training § 250.1504 May I use alternative training methods? You may use... 30 Mineral Resources 2 2013-07-01 2013-07-01 false May I use alternative training methods? 250.1504 Section 250.1504 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT...

  12. ECVAM's approach to intellectual property rights in the validation of alternative methods.

    PubMed

    Linge, Jens P; Hartung, Thomas

    2007-08-01

    In this article, we discuss how intellectual property rights affect the validation of alternative methods at ECVAM. We point out recent cases and summarise relevant EU and OECD documents. Finally, we discuss guidelines for dealing with intellectual property rights during the validation of alternative methods at ECVAM. PMID:17850189

  13. 40 CFR 211.206-3-211.206-10 - Alternative test methods. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Alternative test methods. 211.206-3-211.206-10 Section 211.206-3-211.206-10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...-10 Alternative test methods....

  14. 40 CFR 211.206-3-211.206-10 - Alternative test methods. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Alternative test methods. 211.206-3-211.206-10 Section 211.206-3-211.206-10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...-10 Alternative test methods....

  15. 40 CFR 211.206-3-211.206-10 - Alternative test methods. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Alternative test methods. 211.206-3-211.206-10 Section 211.206-3-211.206-10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...-10 Alternative test methods....

  16. 27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or...

  17. 27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or...

  18. 27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or...

  19. 27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and... OF TAX-FREE ALCOHOL Administrative Provisions Authorities § 22.22 Alternate methods or...

  20. 46 CFR 50.20-30 - Alternative materials or methods of construction.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Alternative materials or methods of construction. 50.20-30 Section 50.20-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Plan Submittal and Approval § 50.20-30 Alternative materials or methods of construction. (a) When new or...

  1. 46 CFR 50.20-30 - Alternative materials or methods of construction.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Alternative materials or methods of construction. 50.20-30 Section 50.20-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Plan Submittal and Approval § 50.20-30 Alternative materials or methods of construction. (a) When new or...

  2. 30 CFR 250.1504 - May I use alternative training methods?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false May I use alternative training methods? 250.1504 Section 250.1504 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT... Control and Production Safety Training § 250.1504 May I use alternative training methods? You may...

  3. 27 CFR 19.666 - Application for and use of an alternate method or procedure.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Application for and use of an alternate method or procedure. 19.666 Section 19.666 Alcohol, Tobacco Products and Firearms... Distilled Spirits for Fuel Use General § 19.666 Application for and use of an alternate method or...

  4. 78 FR 11174 - Recent Postings of Broadly Applicable Alternative Test Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-15

    ... alternative test methods are outlined at 72 FR 4257 (January 30, 2007). We will continue to announce approvals... published at 72 FR 4257 (January 30, 2007) and found on the EPA's Web site at www.epa.gov/ttn/emc/approalt... AGENCY Recent Postings of Broadly Applicable Alternative Test Methods AGENCY: Environmental...

  5. 46 CFR 50.20-30 - Alternative materials or methods of construction.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Alternative materials or methods of construction. 50.20-30 Section 50.20-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Plan Submittal and Approval § 50.20-30 Alternative materials or methods of construction. (a) When new or...

  6. 76 FR 50221 - International Workshop on Alternative Methods for Human and Veterinary Rabies Vaccine Testing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ..., industry, and academia to review the current state of the science and validation status of methods and... Validation of Alternative Methods (ICCVAM), and its international partners identified rabies vaccines as one of the three highest priorities for future research, development, and validation of alternative...

  7. 27 CFR 19.666 - Application for and use of an alternate method or procedure.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Application for and use of an alternate method or procedure. 19.666 Section 19.666 Alcohol, Tobacco Products and Firearms... Distilled Spirits for Fuel Use General § 19.666 Application for and use of an alternate method or...

  8. 27 CFR 19.666 - Application for and use of an alternate method or procedure.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Application for and use of an alternate method or procedure. 19.666 Section 19.666 Alcohol, Tobacco Products and Firearms... Distilled Spirits for Fuel Use General § 19.666 Application for and use of an alternate method or...

  9. 27 CFR 19.666 - Application for and use of an alternate method or procedure.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Application for and use of an alternate method or procedure. 19.666 Section 19.666 Alcohol, Tobacco Products and Firearms... Distilled Spirits for Fuel Use General § 19.666 Application for and use of an alternate method or...

  10. 10 CFR 429.70 - Alternative methods for determining energy efficiency or energy use.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Alternative methods for determining energy efficiency or....70 Alternative methods for determining energy efficiency or energy use. (a) General. A manufacturer... determined the energy efficiency of the basic model, either from testing the basic model or from applying...

  11. 10 CFR 429.70 - Alternative methods for determining energy efficiency or energy use.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Alternative methods for determining energy efficiency or....70 Alternative methods for determining energy efficiency or energy use. Link to an amendment... such equipment in commerce unless the manufacturer has determined the energy efficiency of the...

  12. 10 CFR 429.70 - Alternative methods for determining energy efficiency or energy use.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Alternative methods for determining energy efficiency or....70 Alternative methods for determining energy efficiency or energy use. (a) General. A manufacturer... determined the energy efficiency of the basic model, either from testing the basic model or from applying...

  13. Effectiveness of Alternative Extension Methods through Radio Broadcasting in West Africa

    ERIC Educational Resources Information Center

    Moussa, Bokar; Otoo, Miriam; Fulton, Joan; Lowenberg-DeBoer, James

    2011-01-01

    There is an urgent need to quantify which extension methods are most effective in Africa. The objective of this study was to determine the impact of alternative extension methods on adoption of the triple bagging cowpea storage technology in Niger and Burkina Faso. This study was designed as a quasi-experiment with two alternative extension…

  14. Agar Plate Method for Detection and Enumeration of Alkylbenzenesulfonate-Degrading Microorganisms

    PubMed Central

    Ohwada, Kouichi

    1975-01-01

    A simple method for detection and enumeration of alkylbenzenesulfonate (ABS)-degrading microorganisms by using agar plates was developed and used in microbiological studies of coastal marine and polluted river waters. The method depends upon the color responses of neutral red in alkaline medium. Neutral red changes from pink, when it enters into ABS micelles, to yellow, when the ABS is degraded, and does not form micelles. When neutral red-tris(hydroxymethyl)-aminomethane buffer solution and then cationic surfactant solution were sprayed onto the agar surface of ABS-nutrient agar cultures, transparent haloes appeared around the colonies of ABS-degrading microorganisms against a pink background. Viable counts of ABS-degrading bacteria isolated from both seawater and freshwater environments were considerably higher in polluted waters than in less polluted areas. Viable counts of ABS-degrading bacteria averaged 1.5 × 105/ml in samples from the surface water of polluted Tokyo Bay and 3.0 × 104/ml in samples from the surface water of polluted Tamagawa River but were fewer in number in samples from less polluted waters. Images PMID:234155

  15. A rapid direct telomerase assay method using 96-well streptavidin plates.

    PubMed

    Francis, Rawle; Friedman, Simon H

    2002-05-01

    We have developed a high-throughput direct assay methodfor the assay of telomerase activity that improves on previous direct telomerase assays in two ways that allow larger numbers of samples to be conveniently processed: (i) 96-well streptavidin coated plates are used to bind and wash biotinylated primer extension products from the telomerase assay, as opposed to tubes containing streptavidin-coated magnetic beads; and (ii) storage phosphor-imagery is used instead of film autoradiography to detect telomerase products after being washed and released from the streptavidin-derivatized matrix. This method improves on previous direct assay methods using magnetic beads by allowing larger numbers of samples to be conveniently assayed. Also, the total activity of the radiolabeled nucleotides used in this procedure is significantly lower than that used in standard direct telomerase assays, lowering costs and exposure to radioactivity. We have validated the assay by repeating, in triplicate, the IC50 determination of rivanol, our previously identified telomerase inhibitor. PMID:12019789

  16. Evaluating an alternative method for rapid urinary creatinine determination

    EPA Science Inventory

    Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...

  17. Methods for the evaluation of alternative disaster warning systems

    NASA Technical Reports Server (NTRS)

    Agnew, C. E.; Anderson, R. J., Jr.; Lanen, W. N.

    1977-01-01

    For each of the methods identified, a theoretical basis is provided and an illustrative example is described. The example includes sufficient realism and detail to enable an analyst to conduct an evaluation of other systems. The methods discussed in the study include equal capability cost analysis, consumers' surplus, and statistical decision theory.

  18. Evaluation of alternative methods for estimating reference evapotranspiration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Evapotranspiration is an important component in water-balance and irrigation scheduling models. While the FAO-56 Penman-Monteith method has become the de facto standard for estimating reference evapotranspiration (ETo), it is a complex method requiring several weather parameters. Required weather ...

  19. Alternative Methods to Treat Nausea and Vomiting from Cancer Chemotherapy.

    PubMed

    Sheikhi, Mohammad Ali; Ebadi, Ahmad; Talaeizadeh, Abdolhassan; Rahmani, Hossein

    2015-01-01

    Chemotherapy Induced Nausea and Vomiting (CINV) is among the most intensive side effects and critical concerns for patients with cancer. Most of these patients experience nausea and vomiting after chemotherapy. Sometimes, this is so annoying that it may prevent them from continuing the therapy. With the recent advances, a variety of therapeutic methods are innovated and applied to control CINV. Among them, the main methods include medicinal therapy, relaxation, and herbal therapy. Yet, using dexamethasone together with massage therapy and ginger is identified as the most effective method. PMID:26634155

  20. Alternative Methods to Treat Nausea and Vomiting from Cancer Chemotherapy

    PubMed Central

    Sheikhi, Mohammad Ali; Ebadi, Ahmad; Talaeizadeh, Abdolhassan; Rahmani, Hossein

    2015-01-01

    Chemotherapy Induced Nausea and Vomiting (CINV) is among the most intensive side effects and critical concerns for patients with cancer. Most of these patients experience nausea and vomiting after chemotherapy. Sometimes, this is so annoying that it may prevent them from continuing the therapy. With the recent advances, a variety of therapeutic methods are innovated and applied to control CINV. Among them, the main methods include medicinal therapy, relaxation, and herbal therapy. Yet, using dexamethasone together with massage therapy and ginger is identified as the most effective method. PMID:26634155

  1. An alternative method to screen for pepper spray residue.

    PubMed

    Gillis, Trevor D; Kubic, Thomas A; De Forest, Peter R

    2003-01-01

    A method was developed to screen for pepper spray residue using instruments and methods other than those techniques commonly employed to analyze chemical residue (i.e.. gas chromatography mass spectrometry-GCMS or liquid chromatography mass spectrometry-LCMS). The method employed gas chromatography (GC), thin layer chromatography (TLC), and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) to screen for dried pepper spray stains. Pepper sprays from nine different manufacturers were investigated. Capsaicin and dihydrocapsaicin were identified and unique IR reflectance spectra are presented. An additional five compounds were presumptively found. Results showed that a particular stain could be characterized as a pepper-based stain. PMID:12570209

  2. Alternate cleaning methods for LCCAs. [LCC (Leadless Chip Carriers)

    SciTech Connect

    Adams, B.E.

    1993-04-01

    The purpose of this project was to evaluate DI water followed by isopropyl alcohol (IPA) cleaning and no cleaning of leadless chip carriers (LCCs). Both environmentally safe methods were to be tested against the current chlorofluorocarbon (CFC) material cleaning baseline. Several experiments were run to compare production and electrical yields of LCCs cleaned by all three methods. The critical process steps most affected by cleaning were wire bonding, sealing, particle induced noise detection (PIND), moisture content, and electrical. Yields for the experimental lots cleaned by CFC, DI water plus IPA, and no cleaning were 56%, 72%, and 75%, respectively. The overall results indicated that vapor degreasing/ultrasonic cleaning in CFCs could be replaced by the aqueous method. No cleaning could also be considered if an effective dry method of particle removal could be developed.

  3. Alternate methods for high level pyrotechnic shock simulation

    NASA Astrophysics Data System (ADS)

    Gray, Phillip J., Sr.

    Two effective methods to recreate a realistic pyrotechnic shock are presented. The first method employs a resonant beam and is used for SRS levels of 12,000 G or more. The test unit is at one end of the beam and a hammer strikes the opposite end causing a shock to be transmitted to the other end of the fixture. The second method is based on a standard shaker system with a resonant beam to amplify the input signal. The engineer defines the duration of the shock signal induced to the vibration amplifier using the GenRad 2514 controller. The shock signal is then input via the shaker to the resonant beam, which amplifies the signal to produce the desired response at the end of the fixture. The shock response spectrum stays within a +/-6 dB tolerance with levels as high as 3000 G peak. These methods are repeatable, reliable, cost-effective, and consistent with a real pyroevent.

  4. "Tectonic Petrameter," An Alternative Method to Teaching the Geologic Time Scale

    NASA Astrophysics Data System (ADS)

    Posner, E. S.

    2011-12-01

    I have over a decade of experience as a performance poet and am now a graduate student in the geosciences. I have created a performance poem / play script, "Tectonic Petrameter," as an alternative method of teaching the geologic time scale. "The Archean came next and it was a blast. Tectonic plates were smaller and they moved pretty fast. In an enthusiastic flash of ash, volcanic islands smashed together." The use of rhyme and rhythm presents a different and interdisciplinary approach to teaching Earth history that appeals to a wide range of learning styles and makes science fun, while clearly describing important concepts in geology and events in Earth history. "Now it's time to get down with the Coal Swamp Stomp! Tap your feet to the beat of the formation of peat like a plant plantation soaking up the bright heat." "Tectonic Petrameter" by itself is an illustrated spoken-word poem that leads audiences from all levels of scientific background on an excitingly educational journey through geologic time. I will perform my 10-minute memorized poem and present results from my ongoing study to assess the effectiveness of "Tectonic Petrameter" as a teaching tool in K-12 and introductory undergraduate classroom curricula. I propose that using "Tectonic Petrameter" as a performance piece and theatrical play script in K-12 and introductory undergraduate classrooms, as well as in broader community venues, may be an avenue for breaking down barriers related to teaching about Earth's long and complex history. Digital copies of "Tectonic Petrameter" will be made available to interested parties.

  5. Feasibility and acceptability of alternate methods of postnatal data collection.

    PubMed

    McCormack, Lacey A; Friedrich, Christa; Fahrenwald, Nancy; Specker, Bonny

    2014-05-01

    This study was done in preparation for the launch of the National Children's Study (NCS) main study. The goal of this study was to examine the feasibility (completion rates and completeness of data), acceptability, staff time and cost-effectiveness of three methods of data collection for the postnatal 3- and 9-month questionnaires completed as part of NCS protocol. Eligible NCS participants who were scheduled to complete a postnatal questionnaire at three and nine months were randomly assigned to receive either: (a) telephone data collection (b) web-based data collection, or (c) self-administered (mailed) questionnaires. Event completion rates and satisfaction across the three data collection methods were compared and the influence of socio-demographic factors on completion rates and satisfaction rates was examined. Cost data were compared to data for completion and satisfaction for each of the delivery methods. Completion rates and satisfaction did not differ significantly by method, but completeness of data did, with odds of data completeness higher among web than phone (p < 0.001) or mail (p < 0.001). Costs were highest for the phone, followed by mail and web methods (p < 0.001). No significant differences in participant time (i.e. burden) across the three data collection methods were seen. Mail and phone data collection were the least complete of the three methods and were the most expensive. Mailed data collection was neither complete nor exceptionally economical. Web-based data collection was the least costly and provided the most complete data. Participants without web access could complete the questionnaire over the phone. PMID:23793486

  6. Volumetric topological analysis: a novel method for trabecular bone characterization on the continuum between plates and rods

    NASA Astrophysics Data System (ADS)

    Saha, Punam K.; Xu, Yan; Liang, Guoyuan; Duan, Hong

    2009-02-01

    Trabecular bone (TB) is a complex quasi-random network of interconnected struts and plates. TB constantly remodels to adapt dynamically to the stresses to which it is subjected (Wolff's Law). In osteoporosis, this dynamic equilibrium between bone formation and resorption is perturbed, leading to bone loss and structural deterioration, both increasing fracture risk. Bone's mechanical competence can only be partly explained by variations in bone mineral density, which led to the notion of bone structural quality. Previously, we developed digital topological analysis or DTA which classifies plates, rods, profiles, edges and junctions in a TB skeletal representation. Although the method has become quite popular, a major limitation is that DTA produces hard classifications only, failing to distinguish between narrow and wide plates. Here, we present a new method called volumetric topological analysis or VTA for quantification of regional topology in complex quasi-random TB networks. At each TB voxel, the method uniquely classifies the topology on the continuum between perfect plates and rods. Therefore, the method is capable of detecting early alterations of trabeculae from plates to rods according to the known etiology of osteoporotic bone loss. Here, novel ideas of geodesic distance transform, geodesic scale and feature propagation have been introduced and combined with DTA and fuzzy distance transform methods conceiving the new VTA technology. The method has been applied to MDCT and μCT images of a cadaveric distal tibia specimen and the results have been quantitatively evaluated. Specifically, intra- and inter-modality reproducibility of the method has been examined and the results are found very promising.

  7. Evaluation of Alternate Stainless Steel Surface Passivation Methods

    SciTech Connect

    Clark, Elliot A.

    2005-05-31

    Stainless steel containers were assembled from parts passivated by four commercial vendors using three passivation methods. The performance of these containers in storing hydrogen isotope mixtures was evaluated by monitoring the composition of initially 50% H{sub 2} 50% D{sub 2} gas with time using mass spectroscopy. Commercial passivation by electropolishing appears to result in surfaces that do not catalyze hydrogen isotope exchange. This method of surface passivation shows promise for tritium service, and should be studied further and considered for use. On the other hand, nitric acid passivation and citric acid passivation may not result in surfaces that do not catalyze the isotope exchange reaction H{sub 2} + D{sub 2} {yields} 2HD. These methods should not be considered to replace the proprietary passivation processes of the two current vendors used at the Savannah River Site Tritium Facility.

  8. An alternative simple method in laryngoscope blade decontamination.

    PubMed

    Orhan, Mehmet Emin; Saygun, Onur; Güzeldemir, M Erdal

    2002-06-01

    The cleaning and disinfection of laryngoscope blades is controversial. The aim of this study is to investigate the efficacy of two different chemical disinfectant agents and tap water where the laryngoscope blades were contaminated by different microorganisms and try to create a simple, effective and easy decontamination method. The results of our study demonstrate that the decontamination of the laryngoscope blades, which are cleansed with tap water, is not a reliable approach. In conclusion, mechanical cleaning of blades with water and the immersion in 2% glutaraldehyde or 10% polyvinyl pyrrolidine iodine for 10 minutes is an effective method for decontamination of laryngoscope blades. PMID:12138517

  9. A simple method for classification of antibiotics using ion exchange resins added to agar plates.

    PubMed

    Yoshida, K; Kondo, F

    1994-01-01

    Using two different ion-exchange resins (Dowex 50W-X4 as cation and Dowex 1-X4 as anion) added directly to assay plates seeded with Bacillus subtilis or Micrococcus luteus, the size of the inhibitory zone produced by 36 antimicrobial agents around a disc or cup was characterized into various types, such as acidic, basic or amphoteric. An increase of the inhibition zone following addition of 15% Dowex 50W-X4 was evident in penicillins except for ampicillin and penicillin-G, and polyethers. Aminoglycosides, macrolides and colistin, lincomycin, and sulphonamides on assay medium treated with Dowex 1-X4 showed a similar effect on the inhibition zone. Tetracyclines, virginiamycin, oxolinic acid and furazoridone revealed no effects on the inhibition zone with either of the resins. These antibiotics could be divided into various groups on the basis of their chemical structure. This simple and rapid method may be useful for routine laboratory testing of residual antibiotics in meat. PMID:8152391

  10. Micro-computed tomography: an alternative method for shark ageing.

    PubMed

    Geraghty, P T; Jones, A S; Stewart, J; Macbeth, W G

    2012-04-01

    Micro-computed tomography (microCT) produced 3D reconstructions of shark Carcharhinus brevipinna vertebrae that could be virtually sectioned along any desired plane, and upon which growth bands were readily visible. When compared to manual sectioning, it proved to be a valid and repeatable means of ageing and offers several distinct advantages over other ageing methods. PMID:22497384

  11. Evaluation of Alternative Difference-in-Differences Methods

    ERIC Educational Resources Information Center

    Yu, Bing

    2013-01-01

    Difference-in-differences (DID) strategies are particularly useful for evaluating policy effects in natural experiments in which, for example, a policy affects some schools and students but not others. However, the standard DID method may produce biased estimation of the policy effect if the confounding effect of concurrent events varies by…

  12. FMEA, the alternative process hazard method. [Failure Mode Effects Analysis

    SciTech Connect

    Goyal, R.K. )

    1993-05-01

    Failure mode effects analysis (FMEA) is an old reliability/assurance tool finding its way into the HPI. Not popular yet, this hazard technique has some viable applications that can improve hazard assessment data. Notably, FMEA studies can identify possible areas for improvement that may have not been discovered using other methods. Also, FMEA is not as labor intensive and costly as other process hazard analysis (PHA) methods. PSHA 1910.119 set in place an informational structure whose main purpose is the reduction of potential accidents and minimizing risks in the event of an accident. Consequently, HPI operators must evaluate their process systems and identify potential major hazards, such as fires, explosions and accidental release of toxic/hazardous chemicals, and protect their facilities, employees, the public and the environment. But, which PHA method(s) apply to a particular plant or process still remains a difficult question. This paper describes what FMEA is; types of FMEA; how to conduct a FMEA study; comparison with HAZOP (hazard and operability study); computer software; applicability of FMEA; and examples of its use.

  13. Geospatial methods for monitoring alternative control technology sites

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Soils data can be used to establish nutrient distribution at a selected site; however, soil sampling is labor intensive, costly, and selection of sampling sites may be difficult. This study was conducted to determine if methods developed for the management of saline soils can be applied to a vegetat...

  14. 40 CFR 35.6315 - Alternative methods for obtaining property.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... document a cost comparison analysis to determine which of these methods of obtaining equipment is the most... comparison analysis to EPA for approval. The recipient must obtain the equipment through the most cost..., the recipient may hire the services of a contractor. (ii) The recipient must obtain award...

  15. 40 CFR 35.6315 - Alternative methods for obtaining property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... document a cost comparison analysis to determine which of these methods of obtaining equipment is the most... comparison analysis to EPA for approval. The recipient must obtain the equipment through the most cost..., the recipient may hire the services of a contractor. (ii) The recipient must obtain award...

  16. The alternative methods for disinfection of E. coli

    NASA Astrophysics Data System (ADS)

    Yetim, Tuba; Görmez, Arzu; Gürkök, Sümeyra

    2016-04-01

    Recently, advanced oxidation processes have gained significant interest for bacterial inactivation. In the present study, the efficacy of sonolysis, photocatalysis and sonophotocatalysis was evaluated for disinfection of Escherichia coli O157:H7 strain. Sonophotocatalysis proved to be the most effective disinfection methods by generating greater amount of •OHradical.

  17. A refined higher-order theory and its finite element method for thick laminated plates

    NASA Astrophysics Data System (ADS)

    Fu, Xiaohua; Chen, Haoran; Wang, Zhenming

    1992-04-01

    An improved higher-order theory developed to enhance the accuracy of the shear deformation theory of thick laminated plates is presented. The Legendre polynomials are introduced in the approximate displacement distributions across the plate thickness, and an FEM is suggested from the original equations. The accuracy of the present theory is examined by applying it to bending problems of laminate plates solved by Pagano. The results are compared with 3D elasticity solutions, the second order shear deformation theory, and some other higher-order shear deformation theory solutions. The present theory shows the deflections and stress more accurately than that obtained from previous works in the structural analysis of laminated plates with a small span with respect to thickness.

  18. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    NASA Astrophysics Data System (ADS)

    Wang, Ming-Qiu; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-07-01

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via Nsbnd Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni-P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni-P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  19. Vibration analysis of a thick plate with an interior cut-out by a finite element method

    NASA Astrophysics Data System (ADS)

    Chang, C.-N.; Chiang, F.-K.

    1988-09-01

    Plates with interior openings are often used in industrial design such as machines, bridges, aircraft etc. Many advantages can be obtained by this design, such as reduced weight, easy access for maintenance and an easy assembling process. However, When interior holes are cut from a plate structure, the mechanical behavior of the structure is changed. To avoid induced acoustic noise and/or mechanical failure due to mechanical resonance, vibration problems of such plate structures must be studied. The work reported here is a study of the vibration of a plate with an interior cut-out by a finite element method. Hamilton's variational principal and potential theory are used to derive the governing equations for a Mindlin plate. A quadratic element of eight nodes is used. Selective-reduced integration is used for integration of the stiffness matrix. The locking phenomenon is avoided by this particular integration technique. Eigenvalues and eigenvectors are calculated by subspace iteration. Computations are significantly reduced by this numerical technique. Results are compared with Nagaya's work, and good agreements are obtained.

  20. Finite element method for the rising and the slip of column-plate base for usual connections

    NASA Astrophysics Data System (ADS)

    Hamizi, M.; Aider, H. Ait; Alliche, A.; Hannachi, N. E.

    2010-06-01

    In the present paper, a finite element approach calculating the rising and the relative slip of steel base plate connections is proposed. Two types of connections are studied, the first consists on a base plate welded to the column end and attached to the reinforced concrete foundation by two anchor bolts. These bolts are placed on the major axis of the I shaped section used as column, one anchor bolt on each side of the web. In the second configuration, the connection includes a plate base and four anchor bolts placed out side the flanges of the I shaped section or hallow form. To take in account the real behaviour of this connection, a model by finite elements which considers count geometrical and material no linearties of the contact and cracking in the concrete foundation. To study the rising of the base plate, an approach treating problems of contact-friction between the base plate and the foundation is developed. This approach is based on a unilateral contact law in which a Coulomb friction is added. The numerical resolution is ensured by the increased Lagrangien method. For the behaviour of the concrete foundation, the developed model is based of a compressive elastoplastic model. The heights rising-rotations and the heights rising- slip displacements curves are plotted.

  1. An Alternative Method Of Specifying Shock Test Criteria

    NASA Technical Reports Server (NTRS)

    Ferebee, R. C.; Clayton, J.; Alldredge, D.; Irvine, T.

    2008-01-01

    Shock testing of aerospace vehicle hardware has presented many challenges over the years due to the high magnitude and short duration of the specifications. Recently, component structural failures have occurred during testing that have not manifested themselves on over 200 Space Shuttle solid rocket booster (SRB) flights (two boosters per flight). It is suspected that the method of specifying shock test criteria may be leaving important information out of the test process. The traditional test criteria specification, the shock response spectrum, can be duplicated by any number of waveforms that may not resemble the actual flight test recorded time history. One method of overcoming this limitation is described herein, which may prove useful for qualifying hardware for the upcoming Constellation Program.

  2. Comparison of Two Alternative Methods for Tracking Toe Trajectory

    NASA Technical Reports Server (NTRS)

    Miller, Chris; Peters, Brian; Brady, Rachel; Mulavara, Ajitkumar; Warren, Liz; Feiveson, Al; Bloomberg, Jacob

    2007-01-01

    Toe trajectory during the swing phase of locomotion has been identified as a precise motor control task (Karst, et al., 1999). The standard method for tracking toe trajectory is to place a marker on the superior aspect of the distal end of the 2nd toe itself (Karst, et al., 1999; Winter, 1992). However, others have based their toe trajectory results either on a marker positioned on the lateral aspect of the 5th metatarsal head (Dingwell, et al., 1999; Osaki, et al., 2007), or on a virtual toe marker computed at the anterior tip of the second toe based on the positions of other real foot markers (Miller, et al., 2006). While these methods for tracking the toe may seem similar, their results may not be directly comparable. The purpose of this study was to compute toe trajectory parameters using a 5th metatarsal marker and a virtual toe marker, and compare their results with those of the standard toe marker.

  3. An alternate method for designing dipole magnet ends

    SciTech Connect

    Pope, W.L.; Green, M.A.; Peters, C.; Caspi, S.; Taylor, C.E.

    1988-08-01

    Small bore superconducting dipole magnets, such as those for the SSC, often have problems in the ends. These problems can often be alleviated by spreading out the end windings so that the conductor sees less deformation. This paper presents a new procedure for designing dipole magnet ends which can be applied to magnets with either cylindrical or conical bulged ends to have integrated field multipoles which meet the constraints imposed by the SSC lattice. The method described here permits one to couple existing multiparameter optimization routines (i.e., MINUIT with suitable independent parameter constraints) with a computer code DIPEND, which describes the multiples, so that one can meet any reasonable objective (i.e., minimizing integrated sextupole and decapole). This paper will describe how the computer method was used to analyze the bulged conical ends for an SSC dipole. 6 refs, 6 figs, 2 tabs.

  4. Alternative method for monitoring an in-line CD SEM

    NASA Astrophysics Data System (ADS)

    Herrera, Pedro P.; Dick, Susan A.; Allgair, John A.

    1997-07-01

    Semiconductor manufacturers must ensure that their in-line critical dimension scanning electron microscopes (CD-SEMs) are providing precise and reliable data on a daily basis. As with other process equipment, tool stability and production worthiness is determined by a daily qualification procedure that involves measuring a reference, etched wafer's linewidth and comparing those results to a set target mean. However, repeated exposure to a SEM creates an unacceptable increase in the measured feature's CD. This increase can be disruptive to tool qualification, requires the introduction of new reference wafers, and ultimately limits the tool's availability to production. A new method for daily qualification using a rotating daily job scheme has been developed and employed for monitoring multiple systems at Motorola MOS-13/APRDL. This new procedure allows for better statistical process control, increase the reference wafer's useful life, and provides an easier method of monitoring the tool throughout its lifetime.

  5. The construction of airfoil pressure models by the plate method: Achievements, current research, technology development and potential applications

    NASA Technical Reports Server (NTRS)

    Lawing, P. L.

    1985-01-01

    A method of constructing airfoils by inscribing pressure channels on the face of opposing plates, bonding them together to form one plate with integral channels, and contour machining this plate to form an airfoil model is described. The research and development program to develop the bonding technology is described as well as the construction and testing of an airfoil model. Sample aerodynamic data sets are presented and discussed. Also, work currently under way to produce thin airfoils with camber is presented. Samples of the aft section of a 6 percent airfoil with complete pressure instrumentation including the trailing edge are pictured and described. This technique is particularly useful in fabricating models for transonic cryogenic testing, but it should find application in a wide ange of model construction projects, as well as the fabrication of fuel injectors, space hardware, and other applications requiring advanced bonding technology and intricate fluid passages.

  6. Comparison of polymerase chain reaction methods and plating for analysis of enriched cultures of Listeria monocytogenes when using the ISO11290-1 method.

    PubMed

    Dalmasso, Marion; Bolocan, Andrei Sorin; Hernandez, Marta; Kapetanakou, Anastasia E; Kuchta, Tomáš; Manios, Stavros G; Melero, Beatriz; Minarovičová, Jana; Muhterem, Meryem; Nicolau, Anca Ioana; Rovira, Jordi; Skandamis, Panagiotis N; Stessl, Beatrix; Wagner, Martin; Jordan, Kieran; Rodríguez-Lázaro, David

    2014-03-01

    Analysis for Listeria monocytogenes by ISO11290-1 is time-consuming, entailing two enrichment steps and subsequent plating on agar plates, taking five days without isolate confirmation. The aim of this study was to determine if a polymerase chain reaction (PCR) assay could be used for analysis of the first and second enrichment broths, saving four or two days, respectively. In a comprehensive approach involving six European laboratories, PCR and traditional plating of both enrichment broths from the ISO11290-1 method were compared for the detection of L. monocytogenes in 872 food, raw material and processing environment samples from 13 different dairy and meat food chains. After the first and second enrichments, total DNA was extracted from the enriched cultures and analysed for the presence of L. monocytogenes DNA by PCR. DNA extraction by chaotropic solid-phase extraction (spin column-based silica) combined with real-time PCR (RTi-PCR) was required as it was shown that crude DNA extraction applying sonication lysis and boiling followed by traditional gel-based PCR resulted in fewer positive results than plating. The RTi-PCR results were compared to plating, as defined by the ISO11290-1 method. For first and second enrichments, 90% of the samples gave the same results by RTi-PCR and plating, whatever the RTi-PCR method used. For the samples that gave different results, plating was significantly more accurate for detection of positive samples than RTi-PCR from the first enrichment, but RTi-PCR detected a greater number of positive samples than plating from the second enrichment, regardless of the RTi-PCR method used. RTi-PCR was more accurate for non-food contact surface and food contact surface samples than for food and raw material samples especially from the first enrichment, probably because of sample matrix interference. Even though RTi-PCR analysis of the first enrichment showed less positive results than plating, in outbreak scenarios where a rapid result is

  7. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  8. X-Ray Spectroscopic Analysis of Boron-Nitride Clusters Deposited by Ion-Plating Method

    NASA Astrophysics Data System (ADS)

    Kohzuki, H.; Motoyama, M.; Kaneyoshi, T.; Kowada, Y.; Kawai, J.; Adachi, H.

    Cubic boron-nitride (c-BN) films were deposited on a silicon substrate by varying the deposition time, using a reactive ion-plating method. In order to investigate the growth mechanism of c-BN films, these c-BN films were characterized by x-ray emission spectra of boron (B K x-ray emission spectra), infrared absorption spectra, selected area diffraction patterns, and TEM microstructures. It was found that the BN film with sp2 bonding formed initially on the substrate and subsequently c-BN film formed. The c-BN film was composed of fine crystallites with a size of about 10 nm and with random orientation. In the case of the B K x-ray emission spectrum from the BN film with sp2 bonding, the intensity of the satellite peak at the short-wavelength side was extremely stronger than that of sp2-bonded BN-like turbostratic or hexagonal BN. As a result of calculation of the B K x-ray emission spectrum of BN using the discrete variational Hartree-Fock-Slater (DV-Xα) method, it was found that the satellite peak intensity increased with formation of the fine BN cluster having two-coordinated boron (which has a dangling bond) and with decreasing size of the cluster. Therefore, it is considered that the BN film with sp2 bonding was composed of the very fine BN cluster having two-coordinated borons, and became the precursor of c-BN film at the interface between the substrate and c-BN film.

  9. Alternative lithographic methods for variable aspect ratio vias

    NASA Astrophysics Data System (ADS)

    Schepis, Anthony R.

    The foundation of semiconductor industry has historically been driven by scaling. Device size reduction is enabled by increased pattern density, enhancing functionality and effectively reducing cost per chip. Aggressive reductions in memory cell size have resulted in systems with diminishing area between parallel bit/word lines. This affords an even greater challenge in the patterning of contact level features that are inherently difficult to resolve because of their relatively small area, a product of their two domain critical dimension image. To accommodate these trends there has been a shift toward the implementation of elliptical contact features. This empowers designers to maximize the use of free space between bit/word lines and gate stacks while preserving contact area; effectively reducing the minor via axis dimension while maintaining a patternable threshold in increasingly dense circuitry. It is therefore critical to provide methods that enhance the resolving capacity of varying aspect ratio vias for implementation in electronic design systems. This work separately investigates two unique, non-traditional lithographic techniques in the integration of an optical vortex mask as well as a polymer assembly system as means to augment ellipticity while facilitating contact feature scaling. This document affords a fundamental overview of imaging theory, details previous literature as to the technological trends enabling the resolving of contact features and demonstrates simulated & empirical evidence that the described methods have great potential to extend the resolution of variable aspect ratio vias using lithographic technologies.

  10. 77 FR 17457 - Work Group on Alternative Test Methods for Commercial Measuring Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-26

    ... National Institute of Standards and Technology Work Group on Alternative Test Methods for Commercial...-type volumetric field standards and associated test procedures) widely used by weights and measures officials and service companies to test commercial measuring devices as well as proposed alternatives...

  11. The cervical cap. An alternate barrier contraceptive method.

    PubMed

    Gilbirds, W M; Jonas, H S

    1982-04-01

    The cervical cap is examined as an acceptable addition to barrier method technology. Attention is directed to its history, methodology, contradindications and side effects, effectiveness, and areas of current research. Invention of the modern cervical cap occurred in the mid-1800s. Finch reports that the 1st cervical cap was described in 1838 by Frederick Adolphe Wilde, a German gynecologist. He called it a Cautchuk Pessarium, and each cap was custom made from a wax impression of the woman's cervix. No matter who is credited with the invention of the cap, it remained a widely used method of contraception for the next century although principally employed in Europe. Currently, cervical caps are widely used in England and Central Europe. Use of the cap in the U.S. has been limited by the small amount of data on its demonstrated effectiveness as well as most clinican's belief that the method is too complicated for the "average woman." There are 2 primary types of cervical caps: firm and soft rubber. For the cap to be effective, it must be fitted by trained medical personnel. For maximum effectiveness, it is essential that the cervical cap user master the techniques of self insertion and removal. Most sources recommend that prior to insertion, the cap be approximately 1/3 filled with spermicidal cream or jelly. Whether or not a spermicide is used, the woman assumes a semi-reclining or squatting position. Removal of the cap is facilitated by inserting the index and middle fingers into the vagina and tiling the rim of the cap away from the cervix, thus breaking the suction. The cap can then be easily removed via the inserted fingers. The following conditions contraindicate the use of the cervical cap: cervical erosion or laceration; cervical malformation; Nabothian cysts; inflammation of the adnexa or inability of the woman to place and remove the cap correctly. The only reported side effect of the cap is the presence of a malodorous secretion if the cap is left in place

  12. Alternative methods for the visualization of climate data

    NASA Astrophysics Data System (ADS)

    Nocke, Thomas

    2014-05-01

    The field of climate and climate impact research produces a wide range of heterogeneous data sets to be analyzed and presented. Visualization research - on the other hand - has produced a large number of new visualization techniques and tools in the last decades. However, in typical climate research processes, the number of actually applied visualizations is strongly restricted by the tools at hand and to the most well-known techniques. To bridge this gap, we have tested several state-of-the-art techniques from the fields of information visualization, scientific visualization and statistical visualization to determine their potential within the climate research field. This PICO presentation provides examples from this research, presenting and explaining non-standard visualization methods for climate time series, for spatial scalar / vector climate data and for ensemble climate data.

  13. Fluorescence And Alternative Methods In Urine Drug Testing

    NASA Astrophysics Data System (ADS)

    Jain, Naresh C.

    1988-04-01

    Drug abuse has become-one of the most compelling realities _ ot contemporary society. It has penetrated every segment ot our population: trom schools to sports and trom organized crime to board rooms . Drugs in tie w9rkplace allegedly cost government agencies and business millions ot dollars each year in increased absenteeism,. poor work performance, thefts,accidents andwastedtime. The President's Commission on Organized Crime and the federal government are in tavor ot urine drug testing. In fact many employers are now resorting to urine drug testing on current and prospective employees. This presep.tation discusses different laboratory methods used in urine drug.testing, including immunoassays, fluorescence polarization, thin layer chromatography, high pressure liquid chromatography, gas chromatography and gas-chromatography-mass spectrometry.

  14. Selective deposition on electrodes of chip component by electroless plating method

    NASA Astrophysics Data System (ADS)

    Yamamoto, Akihiro; Watanabe, Nobuaki; Arakawa, Tomiyuki; Gotou, Miku; Nakada, Tatsunosuke; Fukui, Kenta; Hashimoto, Akira; Koiwa, Ichiro

    2014-05-01

    The selective electroless deposition on metallic electrodes of a micro-passive-chip component was investigated. We performed three pretreatments: (a) alkaline degreasing, (b) acid activation, and (c) catalytic activation by the double alternate-dipping method consisting of two steps, i.e., sensitization (SnCl2) and activation (PdCl2). Catalytic conditions such as the concentration of PdCl2, activation time, and number of activation times were optimized to achieve the selectivity of electroless deposition. The mechanism of the selectivity of electroless deposition was investigated by X-ray photoelectron spectroscopy measurements. Tetravalent Sn and metallic Pd are observed on the inner electrode of the sample. On the other hand, metallic Sn and tetravalent Pd are mainly observed in certain areas except the inner electrode areas. These results indicate that the sensitization is performed well in the inner electrode region because Pd must be in a metallic state to validate its catalytic activity.

  15. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution. PMID:24260173

  16. Application of the HHT Method to the Non-contact Thickness Measurement of an Axially Moving Thin Plate

    NASA Astrophysics Data System (ADS)

    Wu, Yangfang; Lu, Qianqian; Xia, Chunlin; Ding, Fan

    2016-06-01

    Non-contact thickness measuring systems can be found in a wide spectrum of technologies. In this paper, Hilbert-Huang transform method is used to analyze the real time signals of a measuring system which includes two round conveyor strings carrying a thin plate, a solar wafer as a sample under test. The vibrations of moving strings and the plate, which are sensitive to moving speed and initial tension in the string, are introduced briefly; the relevant analyses should be helpful for the system design. Using EMD-based time-domain filtering and complementary method, thickness variations and error bands are estimated for different cases. The results show that HHT method as an adaptive time-frequency method, should be potential in measurement engineering applications.

  17. Alternative to the traditional discount method of wholesaler purchasing.

    PubMed

    Lee, G F; Bair, J N; Piz, J W

    1982-07-01

    A program of purchasing drugs from wholesalers at the wholesaler's exact invoice cost plus a percentage is described and compared with the traditional method of average wholesale price (AWP) less a discount. The comparison was conducted by the pharmacy department of a 310-bed, teaching hospital that awarded a one-year contract to a wholesaler offering its items at the exact cost plus a pre-established percentage. Data collected from monthly wholesaler computer printouts gave the following information on each product: (1) list price per item, (2) actual cost to pharmacy per item, (3) percentage discount from AWP, and (4) quantity ordered. The net percentage discount from AWP for 12 months was calculated and compared to the former (traditional) discount rate. The net discount from AWP was 15.6% for purchases made by the hospital during the first 12 months of the program. When compared with the smaller discount the hospital traditionally received, the new program saved the hospital $5758 on annual purchases of $136,419. The actual dollar savings to an institution that changes from a traditional discount program to a cost-plus-percentage program depends on: (1) the negotiated percentage added to wholesaler cost, (2) the discount from AWP that the institution was previously receiving, and (3) the volume of wholesale purchases. PMID:7114064

  18. Identification of Impact Location in a Plate Based on Elastodynamics and Higher Order Time Frequency Method

    NASA Astrophysics Data System (ADS)

    Lee, S. K.; Kim, S. J.

    In a nuclear power plant, impact force due to loose part is related to the structural damage in the plant. In general, the steam generator of the nuclear power plant is structured by thick plate. The paper presents a novel approach to locate an impact load in a thick plate. The approach is based on the analysis of the acoustic waveforms measured by a sensor array located on the plate surface. For accurate estimation of the location of the impact source, the time differences in the arrival times of the waves at the sensors and their propagation velocities are determined. The dispersion curves for multi modes of Lamb wave are calculated by using exact plate theory and SDPT. It is difficult to measure directly the group velocity for Lamb mode of acoustic waveform in the thick plate because they are dispersive wave. However, most of the energy in the wave is carried by the flexural waves (A0 mode), the group velocity of this mode is extracted using the CHOTF technique for estimating the impact source location. The estimates are shown to be in excellent agreement with the actual locations and it is applied to the damage analysis due to the loose part in a nuclear power plant.

  19. An alternate and reversible method for flight restraint of cranes.

    PubMed

    Zhang, Sen Lin; Yang, Shu Hui; Li, Bing; Xu, Yan Chun; Ma, Jian Hua; Xu, Jian Feng; Zhang, Xian Guang

    2011-01-01

    Flight restraint is important for zoos, safaris, and breeding centers for large birds. Currently used techniques for flight restraint include both surgical and non-surgical approaches. Surgical approaches usually cause permanent change to or removal of tendon, patagial membrane, or wing bones, and can cause pain and inflammation. Non-surgical approaches such as clipping or trimming feathers often alter the bird's appearance, and can damage growing blood feathers in fledglings or cause joint stiffness. We observed microstructure of primary feathers of the red-crowned crane (Grus japonensis) and found that the width of barbs is a determinative factor influencing vane stiffness and geometric parameters. We hypothesized that partial longitudinal excision of barbs on the ventral surface of the primary feathers would reduce the stiffness of the vane and render the feathers unable to support the crane's body weight during flight. Furthermore, we hypothesized that this modification of barbs would also change the aerodynamic performance of feathers such that they could not generate sufficient lift and thrust during flapping to enable the bird to fly. We tested this hypothesis on a red-crowned crane that had normal flight capability by excising the ventral margin of barbs on all 10 primaries on the left wing. The bird was unable to take off until the modified feathers were replaced by new ones. Removal of barbs proved to be a simple, non-invasive, low-cost and reversible method for flight restraint. It is potentially applicable to other large birds with similar structural characteristics of primary feathers. PMID:21538502

  20. 27 CFR 46.261 - Purpose of an alternate method or procedure.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures §...

  1. 27 CFR 46.261 - Purpose of an alternate method or procedure.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures §...

  2. 27 CFR 46.261 - Purpose of an alternate method or procedure.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures §...

  3. 27 CFR 46.261 - Purpose of an alternate method or procedure.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures §...

  4. 78 FR 45253 - National Toxicology Program Scientific Advisory Committee on Alternative Toxicological Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-26

    ... HUMAN SERVICES National Institutes of Health National Toxicology Program Scientific Advisory Committee... notice announces a meeting of the Scientific Advisory Committee on Alternative Toxicological Methods... and promotes the scientific validation and regulatory acceptance of toxicological and...

  5. Evaluation Standards for the Assessment of Alternative Testing Methods: An Application.

    ERIC Educational Resources Information Center

    Nevo, David; Shohamy, Elana

    1986-01-01

    This study tested the validity and applicability of the Standards for Evaluation of Education Programs, Projects and Materials (Joint Committee, 1981) by applying them to four alternative methods of testing oral proficiency in English as a Foreign Language. (BS)

  6. 76 FR 9777 - Recent Postings of Broadly Applicable Alternative Test Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ...This notice announces the broadly applicable alternative test method approval decisions that EPA has made under and in support of New Source Performance Standards (NSPS) and the National Emission Standards for Hazardous Air Pollutants (NESHAP) in...

  7. A Rapid Microtiter Plate Method To Measure Carbon Dioxide Evolved from Carbon Substrate Amendments so as To Determine the Physiological Profiles of Soil Microbial Communities by Using Whole Soil

    PubMed Central

    Campbell, Colin D.; Chapman, Stephen J.; Cameron, Clare M.; Davidson, Mitchell S.; Potts, Jacqueline M.

    2003-01-01

    Sole-carbon-source tests (Biolog), designed to identify bacteria, have become very popular for metabolically fingerprinting soil microbial communities, despite disadvantages associated with the use of carbon source profiles that primarily select for fast-growing bacteria. In this paper we describe the use of an alternative method that combines the advantages of the Biolog community-level physiological profile (CLPP) method, in which microtiter-based detection plates are used, with the ability to measure carbon dioxide evolution from whole soil. This method facilitates measurement over short periods of time (4 to 6 h) and does not require the extraction and culturing of organisms. Deep-well microtiter plates are used as test wells into which soil is placed. The apparatus to fill the deep-well plates and interface it with a second removable detection plate is described. Two detection systems, a simple colorimetric reaction in absorbent alkali and scintillation counting with radioactive carbon sources, are described. The methods were compared to the Biolog-CLPP system by using soils under different vegetation types and soil treated with wastewater sludge. We aimed to test the hypothesis that using whole soil would have specific advantages over using extracts in that more immediate responses to substrates could be obtained that would reflect activity rather than growth. The whole-soil method was more rapid and gave earlier detection of C source use. Also, the metabolic fingerprints obtained could discriminate between sludge treatments. PMID:12788767

  8. The Continuized Log-Linear Method: An Alternative to the Kernel Method of Continuization in Test Equating

    ERIC Educational Resources Information Center

    Wang, Tianyou

    2008-01-01

    Von Davier, Holland, and Thayer (2004) laid out a five-step framework of test equating that can be applied to various data collection designs and equating methods. In the continuization step, they presented an adjusted Gaussian kernel method that preserves the first two moments. This article proposes an alternative continuization method that…

  9. Methods for the evaluation of alternative disaster warning systems. Executive summary

    NASA Technical Reports Server (NTRS)

    Agnew, C. E.; Anderson, R. J., Jr.; Lanen, W. N.

    1977-01-01

    Methods for estimating the economic costs and benefits of the transmission-reception and reception-action segments of a disaster warning system (DWS) are described. Methods were identified for the evaluation of the transmission and reception portions of alternative disaster warning systems. Example analyses using the methods identified were performed.

  10. School's IN for Summer: An Alternative Field Experience for Elementary Science Methods Students

    ERIC Educational Resources Information Center

    Hanuscin, Deborah L.; Musikul, Kusalin

    2007-01-01

    Field experiences are critical to teacher learning and enhance the effectiveness of methods courses; however, when methods courses are offered in the summer, traditional school-based field experiences are not possible. This article describes an alternative campus-based experience created as part of an elementary science methods course. The Summer…

  11. Alternative Methods for Validating Admissions and Course Placement Criteria. AIR 1995 Annual Forum Paper.

    ERIC Educational Resources Information Center

    Noble, Julie; Sawyer, Richard

    Correlational methods are compared to an alternative method based on decision theory and logistic regression for providing validity evidence for college admissions and course placement criteria. The advantages and limitations of both methods are examined. The correlation coefficient measures the strength of the linear statistical relationship…

  12. Experimental modal analysis of an aluminum rectangular plate by use of the slope-assisted BOTDA method

    NASA Astrophysics Data System (ADS)

    Minardo, A.; Coscetta, A.; Pirozzi, S.; Bernini, R.; Zeni, L.

    2013-12-01

    We report an experimental modal analysis of an aluminum rectangular plate (50 cm×30 cm×0.3 cm), carried out by use of a Brillouin optical time-domain analysis (BOTDA) sensor operating in the slope-assisted configuration, i.e. at a fixed pump-probe frequency shift. Strain measurements were acquired along an optical fiber attached to the structure, at a maximum acquisition rate of 250 Hz, a spatial resolution of 30 cm and a sampling distance of 5 cm in both x- and y-directions. A sequence of dynamic tests, aimed to evaluate the resonant frequencies and strain modal shapes of the structure, were performed on the plate for various boundary conditions (plate clamped with four, three or two bolts). Comparison with finite element method (FEM) analysis and dynamic strain measurements with strain gauges shows that Brillouin based distributed sensors can be usefully employed to perform the modal analysis of a vibrating structure, even if the spatial resolution is comparable with the plate dimensions.

  13. A practical method to follow the evolution of electrochemically active areas during plate formation processes in lead acid batteries

    NASA Astrophysics Data System (ADS)

    D'Alkaine, C. V.; de Andrade, J.; Impinnisi, P. R.

    A new method to follow the evolution of the plates of a battery during the formation processes is proposed and developed. The developed methodology can be used not only in research but also in the factory laboratories due to its simplicity. To exemplify the methodology, results for formation processes of tubular plates are presented using as precursor PbO or Pb 3O 4. The methodology gives access to the evolution, during its formation process, of the portions of the active material available for the discharge processes, the so called electrochemically active area. At the same time, the proposed technique permits the determination of the whole amount of PbO 2 during formation. Through the results it is pointed out what experimental conditions must be used during the application of the method and examples are given of the kinds of interpretation that can be made. Finally, information is presented which was deduced from the results presented.

  14. Comparison of soil moisture retention characteristics obtained by the extended evaporation method and the pressure plate/sand box apparatus

    NASA Astrophysics Data System (ADS)

    Öztürk, Hasan S.; Durner, Wolfgang; Haghverdi, Amir; Walter, Birgit

    2013-04-01

    The water retention curve (WRC) characterizes the capacity of soil to hold water at specified soil matric potentials. It is a key property in any soil hydrologic application. To determine water retention data accurately and in turn use them to draw the whole curve by optimizing parameters of a proper soil hydraulic equation, it is of crucial importance to choose a suitable measurement procedure. For many years, the sand box-pressure plate apparatus are widely accepted as a reference laboratory procedure. To overcome shortcomings of the pressure plate, the evaporation method was introduced, besides many others. The method is not dependent on hydrostatic equilibrium conditions, thus allowing much quicker measurements, and yields the WRC in very high resolution. The method furthermore enables to quantify the unsaturated hydraulic conductivity function. We investigated a set of 40 fine-textured soils with both methods. The samples were packed from aggregated, dried and sieved material. Eight (-5, -10, -33, -100, -400, -700,-1000 and -1500kPa) water retention data points were obtained from sand box-pressure plate apparatus. Evaporation measurements were performed with the commercial apparatus HYPROP by UMS GmbH, Munich, applying the extended method, which yields water retention data in the range from 0 to -500kPa. We found that the sand box-pressure plate method lead to immediate drainage of water, whereas in HYPROP water started to drain only after reaching an air-entry point of pF 1.2-1.3. Accordingly, HYPROP gave higher water contents until pF 2, compared to the sand box/pressure plate apparatus, but from this point on both curves begin to be close and around the field capacity (pF 2.5) they overlap. Both methods show that the textural pore system starts to drain much later, around pF 3.5. We hypothesize that the reason for the different drainage behaviour of the interaggrate pore system lies in the saturation procedure. For HYPROP, samples were saturated under

  15. Aiding alternatives assessment with an uncertainty-tolerant hazard scoring method.

    PubMed

    Faludi, Jeremy; Hoang, Tina; Gorman, Patrick; Mulvihill, Martin

    2016-11-01

    This research developed a single-score system to simplify and clarify decision-making in chemical alternatives assessment, accounting for uncertainty. Today, assessing alternatives to hazardous constituent chemicals is a difficult task-rather than comparing alternatives by a single definitive score, many independent toxicological variables must be considered at once, and data gaps are rampant. Thus, most hazard assessments are only comprehensible to toxicologists, but business leaders and politicians need simple scores to make decisions. In addition, they must balance hazard against other considerations, such as product functionality, and they must be aware of the high degrees of uncertainty in chemical hazard data. This research proposes a transparent, reproducible method to translate eighteen hazard endpoints into a simple numeric score with quantified uncertainty, alongside a similar product functionality score, to aid decisions between alternative products. The scoring method uses Clean Production Action's GreenScreen as a guide, but with a different method of score aggregation. It provides finer differentiation between scores than GreenScreen's four-point scale, and it displays uncertainty quantitatively in the final score. Displaying uncertainty also illustrates which alternatives are early in product development versus well-defined commercial products. This paper tested the proposed assessment method through a case study in the building industry, assessing alternatives to spray polyurethane foam insulation containing methylene diphenyl diisocyanate (MDI). The new hazard scoring method successfully identified trade-offs between different alternatives, showing finer resolution than GreenScreen Benchmarking. Sensitivity analysis showed that different weighting schemes in hazard scores had almost no effect on alternatives ranking, compared to uncertainty from data gaps. PMID:27454102

  16. Static analysis of the hull plate using the finite element method

    NASA Astrophysics Data System (ADS)

    Ion, A.

    2015-11-01

    This paper aims at presenting the static analysis for two levels of a container ship's construction as follows: the first level is at the girder / hull plate and the second level is conducted at the entire strength hull of the vessel. This article will describe the work for the static analysis of a hull plate. We shall use the software package ANSYS Mechanical 14.5. The program is run on a computer with four Intel Xeon X5260 CPU processors at 3.33 GHz, 32 GB memory installed. In terms of software, the shared memory parallel version of ANSYS refers to running ANSYS across multiple cores on a SMP system. The distributed memory parallel version of ANSYS (Distributed ANSYS) refers to running ANSYS across multiple processors on SMP systems or DMP systems.

  17. An equilibrium method for prediction of transverse shear stresses in a thick laminated plate

    NASA Technical Reports Server (NTRS)

    Chaudhuri, R. Z.

    1986-01-01

    First two equations of equilibrium are utilized to compute the transverse shear stress variation through thickness of a thick laminated plate after in-plane stresses have been computed using an assumed quadratic displacement triangular element based on transverse inextensibility and layerwise constant shear angle theory (LCST). Centroid of the triangle is the point of exceptional accuracy for transverse shear stresses. Numerical results indicate close agreement with elasticity theory. An interesting comparison between the present theory and that based on assumed stress hybrid finite element approach suggests that the latter does not satisfy the condition of free normal traction at the edge. Comparison with numerical results obtained by using constant shear angle theory suggests that LCST is close to the elasticity solution while the CST is closer to classical (CLT) solution. It is also demonstrated that the reduced integration gives faster convergence when the present theory is applied to a thin plate.

  18. Measuring and scanning methods in astrometric processing of the photographic plates

    NASA Astrophysics Data System (ADS)

    Bocsa, Gheorghe; Tsvetkov, Milcho

    2008-09-01

    This paper is dedicated to the first comparative study concerning position determinations of selected small bodies in the solar system observed with the Bucharest Observatory equatorial PRIN-MERTZ refractor (d = 0.38m, f = 6.0m) by means of the Carl-Zeiss ASCORECORD measurements and the processing of 5 photographic plates dating from 1971, digitized with the EPSON 1640XL flatbed scanner of the Sofia. The calculations were done with PC computer, with the same program for both cases using a double precision accuracy on the way to compare manual measurements and data processing using the digitized plates. The scan resolution used was 1600 dpi-14 bit grayscale up to 3.6 densities. With this scale 1 pix = 15.875 microns we had the extended field of 15184×15219 pix. The format of the scans was FITS using the standard twain driver for EPSON 1640XL and software developed by S. Mottola.

  19. Gel microbead cultivation with a subenrichment procedure can yield better bacterial cultivability from a seawater sample than standard plating method

    NASA Astrophysics Data System (ADS)

    Ji, Shiqi; Zhao, Rui; Yin, Qi; Zhao, Yuan; Liu, Chenguang; Xiao, Tian; Zhang, Xiaohua

    2012-03-01

    A gel microbead (GMD) cultivation method was employed to cultivate microorganisms from an amphioxus breeding zone in Qingdao, P. R. China. The culture results were compared with those by standard plating method. In the GMD-based method, the microcolony-forming GMDs were sorted by fluorescence-activated cell sorting (FACS). To further get pure cultures, a subsequent enrichment culture and a streaking purification procedure were conducted on marine R2A medium. Eighty bacterial strains isolated by the GMD-based method were randomly selected for sequencing. These isolates belonged to Alphaproteobacteria (33%), Gammaproteobacteria (44%), Bacteroidetes (11%), Actinobacteria (5%), Firmicutes (5%), Epsilonproteobacteria (1%), and Verrucomicrobia (1%), the last two groups being usually difficult to culture. The 16S rRNA gene sequences revealed a diverse community with 91.1%-100% of the bacterial rRNAs similarities. Thirteen strains were sharing 16S rRNA gene sequence which was less than 97% similar to any other rRNA genes currently deposited in TYP16S database. Seventy isolates derived from the standard plating method fell into 4 different taxonomic groups: Alphaproteobacteria (9%), Gammaproteobacteria (81%), Bacteroidetes (7%) and Firmicutes (3%) with a 16S rRNA gene sequence similarities between 95.8%-100%, in which only 3 strains were sharing 16S rRNA gene sequence of less than 97%. The results indicated that the GMD-based method with subenrichment culture yielded more taxonomic groups and more novel microbial strains, including members of previously rarely cultured groups, when compared with the standard plating method, and that this method markedly improved the bacterial cultivability.

  20. A fictitious domain method for fluid/solid interaction applied to the plate folding over the 660 Km depth boundary.

    NASA Astrophysics Data System (ADS)

    Cerpa, Nestor; Hassani, Riad; Gerbault, Muriel

    2014-05-01

    A large variety of geodynamical problems involve a mechanical system where a competent body is embedded in a more deformable medium, and hence they can be viewed as belonging to the field of solid/fluid interaction.The lithosphere/asthenosphere interaction in subduction zones is among those kind of problems which are generally difficult to tackle numerically since the immersed (solid) body can be geometrically complex and the surrounding (fluid) medium can thus undergo large deformation. Our work presents a new numerical approach for the study of subduction zones. The lithosphere is modeled as a Maxwell viscoelastic body sinking in the viscous asthenosphere. Both domains are discretized by the Finite Element Method (FEM) and we use a staggered coupling method. The interaction is provided by a non-matching interface method called the Fictitious Domain Method (FDM). We have validated this method with some 2-D benchmarks and examples. Through this numerical coupling method we aim at studying the effect of mantle viscosity on the cyclicity of slab folding on the 660 km depth discontinuity approximated as an impenetrable barrier. Depending on the kinematics condition imposed to the overriding and subducting plates, analog and numerical models have previously shown that cyclicity occurs. The viscosity of the asthenosphere (taken as an isoviscous or a double viscosity-layer fluid) impacts on folding cyclicity and consequently on the slab's dip as well as the stress regime of the overriding plate. In particular, applying far-field plate velocities corresponding to those of the South-American and Nazca plates at present, (4.3 cm/yr and 2.9 cm/yr respectively), we obtain periodic slab folding which is consistent with magmatism and sedimentalogical records. These data report cycles in orogenic growth of the order of 30-40 Myrs, a period that we reproduce when the mantle viscosity ranges in between 3 and 5 x 1020 Pa.s. Moreover, we reproduce episodic development of horizontal

  1. Study of alternate methods of disposal of propellants and gases at KSC

    NASA Technical Reports Server (NTRS)

    Moore, W. I.

    1970-01-01

    A comprehensive study was conducted at KSC launch support facilities to determine the nature and extent of potential hazards from propellant and gas releases to the environment. The results of the study, alternate methods for reducing or eliminating the hazards, and recommendations pertaining to these alternatives are presented. The operational modes of the propellant or hazardous gas systems considered include: system charging, system standby, system operation, and post-test operations. The results are outlined on an area-by-area basis.

  2. A method for measuring skin friction drag on a flat plate in contaminated gas flows

    NASA Technical Reports Server (NTRS)

    Oetting, R. B.; Patterson, G. K.

    1984-01-01

    A technique for measuring friction drag in turbulent gas and gas/particle flows over flat plates is presented, and preliminary results are reported. A 0.25-in.-thick 72 x 6-in. Al plate is suspended by six horizontal support air bearings and four vertical alignment air bearings between fixed dummy plates and leading-edge and trailing-edge fairings in the 32-in.-high 48-in.-wide 11-ft-long test section of a closed-circuit atmospheric wind tunnel operating at 50-150 ft/sec. Particles of Fe and Al oxides of diameter 20-150 microns and density up to 0.3 lb particles per lb air are injected via a 6 x 0.167-in. nozzle; turbulence is induced by a roughened section of the leading-edge fairing; and friction drag is measured using a load-cell pressure transducer. Sample results are shown in a graph, demonstrating good agreement with theoretical drag calculations.

  3. Alternative Structures and Methods in Teacher Education. Report of a Technical Working Group (Kathmandu, Nepal, October 21-30, 1975).

    ERIC Educational Resources Information Center

    Philippines Univ., Quezon City. Asian Inst. for Teacher Educators.

    The technical working group meeting on alternative structures and methods in teacher education met to: 1) examine case studies prepared on alternative structures and methods in teacher education and other relevant materials; 2) prepare models of alternative structures and methods in teacher training; and 3) make suggestions on field-testing of…

  4. 29 CFR 2520.104-44 - Limited exemption and alternative method of compliance for annual reporting by unfunded plans and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Limited exemption and alternative method of compliance for... Limited exemption and alternative method of compliance for annual reporting by unfunded plans and by...) of this section. (2) Under the authority of section 110 of the Act, an alternative method...

  5. 29 CFR 2520.104-44 - Limited exemption and alternative method of compliance for annual reporting by unfunded plans and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Limited exemption and alternative method of compliance for... Limited exemption and alternative method of compliance for annual reporting by unfunded plans and by...) of this section. (2) Under the authority of section 110 of the Act, an alternative method...

  6. 29 CFR 2520.104-44 - Limited exemption and alternative method of compliance for annual reporting by unfunded plans and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Limited exemption and alternative method of compliance for... Limited exemption and alternative method of compliance for annual reporting by unfunded plans and by...) of this section. (2) Under the authority of section 110 of the Act, an alternative method...

  7. 29 CFR 2520.104-44 - Limited exemption and alternative method of compliance for annual reporting by unfunded plans and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Limited exemption and alternative method of compliance for... Limited exemption and alternative method of compliance for annual reporting by unfunded plans and by...) of this section. (2) Under the authority of section 110 of the Act, an alternative method...

  8. 29 CFR 2520.104-44 - Limited exemption and alternative method of compliance for annual reporting by unfunded plans and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Limited exemption and alternative method of compliance for... Limited exemption and alternative method of compliance for annual reporting by unfunded plans and by...) of this section. (2) Under the authority of section 110 of the Act, an alternative method...

  9. An approximate semi-analytical method for prediction of interlaminar shear stresses in an arbitrarily laminated thick plate

    NASA Technical Reports Server (NTRS)

    Chaudhuri, Reaz A.; Seide, Paul

    1987-01-01

    An approximate semianalytical method for determination of interlaminar shear stress distribution through the thickness of an arbitrarily laminated thick plate has been presented. The method is based on the assumptions of transverse inextensibility and layerwise constant shear angle theory (LCST) and utilizes an assumed quadratic displacement potential energy based finite element method (FEM). Centroid of the triangular surface has been proved from a rigorous mathematical point of view (Aubin-Nitsche theory), to be the point of exceptional accuracy for the interlaminar shear stresses. Numerical results indicate close agreement with the available three-dimensional elasticity theory solutions. A comparison between the present theory and that due to an assumed stress hybrid FEM suggest that the (normal) traction-free-edge condition is not satisfied in the latter approach. Furthermore, the present paper is the first to present the results for interlaminar shear stresses in a two-layer thick square plate of balanced unsymmetric angle-ply construction. A comparison with the recently proposed Equilibrium Method (EM) indicates the superiority of the present method, because the latter assures faster convergence as well as simultaneous vanishing of the transverse shear stresses on both of the exposed surfaces of the laminate. Superiority of the present method over the EM, in the case of a symmetric laminate, is limited to faster convergence alone. It has also been demonstrated that the combination of the present method and the reduced (quadratic order) numerical integration scheme yields convergence of the interlaminar shear stresses almost as rapidly as that of the nodal displacements, in the case of a thin plate.

  10. A correlation method to predict the surface pressure distribution on an infinite plate from which a jet is issuing. [effects of a lifting jet

    NASA Technical Reports Server (NTRS)

    Perkins, S. C., Jr.; Menhall, M. R.

    1978-01-01

    A correlation method to predict pressures induced on an infinite plate by a jet issuing from the plate into a subsonic free stream was developed. The complete method consists of an analytical method which models the blockage and entrainment properties of the jet and a correlation which accounts for the effects of separation. The method was developed for jet velocity ratios up to ten and for radial distances up to five diameters from the jet. Correlation curves and data comparisons are presented for jets issuing normally from a flat plate with velocity ratios one to twelve. Also, a list of references which deal with jets in a crossflow is presented.

  11. A Web-based Alternative Non-animal Method Database for Safety Cosmetic Evaluations.

    PubMed

    Kim, Seung Won; Kim, Bae-Hwan

    2016-07-01

    Animal testing was used traditionally in the cosmetics industry to confirm product safety, but has begun to be banned; alternative methods to replace animal experiments are either in development, or are being validated, worldwide. Research data related to test substances are critical for developing novel alternative tests. Moreover, safety information on cosmetic materials has neither been collected in a database nor shared among researchers. Therefore, it is imperative to build and share a database of safety information on toxicological mechanisms and pathways collected through in vivo, in vitro, and in silico methods. We developed the CAMSEC database (named after the research team; the Consortium of Alternative Methods for Safety Evaluation of Cosmetics) to fulfill this purpose. On the same website, our aim is to provide updates on current alternative research methods in Korea. The database will not be used directly to conduct safety evaluations, but researchers or regulatory individuals can use it to facilitate their work in formulating safety evaluations for cosmetic materials. We hope this database will help establish new alternative research methods to conduct efficient safety evaluations of cosmetic materials. PMID:27437094

  12. A Web-based Alternative Non-animal Method Database for Safety Cosmetic Evaluations

    PubMed Central

    Kim, Seung Won; Kim, Bae-Hwan

    2016-01-01

    Animal testing was used traditionally in the cosmetics industry to confirm product safety, but has begun to be banned; alternative methods to replace animal experiments are either in development, or are being validated, worldwide. Research data related to test substances are critical for developing novel alternative tests. Moreover, safety information on cosmetic materials has neither been collected in a database nor shared among researchers. Therefore, it is imperative to build and share a database of safety information on toxicological mechanisms and pathways collected through in vivo, in vitro, and in silico methods. We developed the CAMSEC database (named after the research team; the Consortium of Alternative Methods for Safety Evaluation of Cosmetics) to fulfill this purpose. On the same website, our aim is to provide updates on current alternative research methods in Korea. The database will not be used directly to conduct safety evaluations, but researchers or regulatory individuals can use it to facilitate their work in formulating safety evaluations for cosmetic materials. We hope this database will help establish new alternative research methods to conduct efficient safety evaluations of cosmetic materials. PMID:27437094

  13. Recommendations for Developing Alternative Test Methods for Screening and Prioritization of Chemicals for Developmental Neurotoxicity

    EPA Science Inventory

    Developmental neurotoxicity testing (DNT) is perceived by many stakeholders to be an area in critical need of alternative methods to current animal testing protocols and gUidelines. An immediate goal is to develop test methods that are capable of screening large numbers of chemic...

  14. An Alternative Method to Gauss-Jordan Elimination: Minimizing Fraction Arithmetic

    ERIC Educational Resources Information Center

    Smith, Luke; Powell, Joan

    2011-01-01

    When solving systems of equations by using matrices, many teachers present a Gauss-Jordan elimination approach to row reducing matrices that can involve painfully tedious operations with fractions (which I will call the traditional method). In this essay, I present an alternative method to row reduce matrices that does not introduce additional…

  15. A Static Method as an Alternative to Gel Chromatography: An Experiment for the Undergraduate Biochemistry Laboratory

    ERIC Educational Resources Information Center

    Burum, Alex D.; Splittgerber, Allan G.

    2008-01-01

    This article describes a static method as an alternative to gel chromatography, which may be used as an undergraduate laboratory experiment. In this method, a constant mass of Sephadex gel is swollen in a series of protein solutions. UV-vis spectrophotometry is used to find a partition coefficient, KD, that indicates the fraction of the interior…

  16. 27 CFR 46.261 - Purpose of an alternate method or procedure.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for Sale on April 1, 2009 Alternate Methods Or Procedures § 46.261... method or procedure. 46.261 Section 46.261 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO...

  17. Overview On Alternate Asbestos Control Method Research And NESHAP Comparison - Nashville, TN

    EPA Science Inventory

    The alternative asbestos control method (AACM) is an experimental approach to building demolition. Unlike the NESHAP method, the AACM allows some regulated asbestos containing material to remain in the building and a surfactant-water solution is used to suppress asbestos fibers ...

  18. Paper microzone plates.

    PubMed

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader. PMID:19572563

  19. Electrohydrodynamic flow in a wire-plate non-thermal plasma reactor measured by 3D PIV method

    NASA Astrophysics Data System (ADS)

    Podlinski, J.; Niewulis, A.; Mizeraczyk, J.

    2009-08-01

    This work was aimed at measurements of the electrohydrodynamic (EHD) secondary flow in a non-thermal plasma reactor using three-dimensional particle image velocimetry (3D PIV) method. The wide-type non-thermal plasma reactor used in this work was an acrylic box with a wire discharge electrode and two plate collecting electrodes. The positive DC voltage was applied to the wire electrode through a 10 MΩ resistor. The collecting electrodes were grounded. The voltage applied to the wire electrode was 28 kV. Air flow seeded with a cigarette smoke was blown along the reactor duct with an average velocity of 0.6 m/s. The 3D PIV velocity fields measurements were carried out in four parallel planes stretched along the reactor duct, perpendicularly to the wire electrode and plate electrodes. The measured flow velocity fields illustrate complex nature of the EHD induced secondary flow in the non-thermal plasma reactor.

  20. Experience of the Indirect Neutron Radiography Method Based on the X-ray Imaging Plate at CARR

    NASA Astrophysics Data System (ADS)

    Wei, Guohai; Han, Songbai; Wang, Hongli; He, Linfeng; Wang, Yu; Wu, Meimei; Liu, Yuntao; Chen, Dongfeng

    Indirect neutron radiography (INR) experiments by X-ray imaging plate were carried out at the China Advanced Research Reactor (CARR). The key experiment parameters were optimized, especially the exposure time of the neutron converter andimaging plate. The optimized total exposure time is 37.25 min, it is two-fifths of the timebased on the film method under the same experimental conditions. The qualitative and quantitativeinspections were tested with dummy nuclear fuel rods and a water temperaturesensor ofa motor vehicle. The spring in the sensor and the defects of the dummy fuel rod's pellets can be qualitatively detected. The thickness of the tape at one position on the cladding of the dummy nuclear fuel rodwas quantitatively calculated to be 9.57 layers with the relative error of ±4.3%.

  1. An optimal open/closed-loop control method with application to a pre-stressed thin duralumin plate

    NASA Astrophysics Data System (ADS)

    Nadimpalli, Sruthi Raju

    The excessive vibrations of a pre-stressed duralumin plate, suppressed by a combination of open-loop and closed-loop controls, also known as open/closed-loop control, is studied in this thesis. The two primary steps involved in this process are: Step (I) with an assumption that the closed-loop control law is proportional, obtain the optimal open-loop control by direct minimization of the performance measure consisting of energy at terminal time and a penalty on open-loop control force via calculus of variations. If the performance measure also involves a penalty on closed-loop control effort then a Fourier based method is utilized. Step (II) the energy at terminal time is minimized numerically to obtain optimal values of feedback gains. The optimal closed-loop control gains obtained are used to describe the displacement and the velocity of open-loop, closed-loop and open/closed-loop controlled duralumin plate.

  2. Application of He's homotopy perturbation method to boundary layer flow and convection heat transfer over a flat plate

    NASA Astrophysics Data System (ADS)

    Esmaeilpour, M.; Ganji, D. D.

    2007-12-01

    In this Letter, the problem of forced convection over a horizontal flat plate is presented and the homotopy perturbation method (HPM) is employed to compute an approximation to the solution of the system of nonlinear differential equations governing on the problem. It has been attempted to show the capabilities and wide-range applications of the homotopy perturbation method in comparison with the previous ones in solving heat transfer problems. The obtained solutions, in comparison with the exact solutions admit a remarkable accuracy. A clear conclusion can be drawn from the numerical results that the HPM provides highly accurate numerical solutions for nonlinear differential equations.

  3. Alternative methods of accounting for underreporting and overreporting when measuring dietary intake-obesity relations.

    PubMed

    Mendez, Michelle A; Popkin, Barry M; Buckland, Genevieve; Schroder, Helmut; Amiano, Pilar; Barricarte, Aurelio; Huerta, José-María; Quirós, José R; Sánchez, María-José; González, Carlos A

    2011-02-15

    Misreporting characterized by the reporting of implausible energy intakes may undermine the valid estimation of diet-disease relations, but the methods to best identify and account for misreporting are unknown. The present study compared how alternate approaches affected associations between selected dietary factors and body mass index (BMI) by using data from the European Prospective Investigation Into Cancer and Nutrition-Spain. A total of 24,332 women and 15,061 men 29-65 years of age recruited from 1992 to 1996 for whom measured height and weight and validated diet history data were available were included. Misreporters were identified on the basis of disparities between reported energy intakes and estimated requirements calculated using the original Goldberg method and 2 alternatives: one that substituted basal metabolic rate equations that are more valid at higher BMIs and another that used doubly labeled water-predicted total energy expenditure equations. Compared with results obtained using the original method, underreporting was considerably lower and overreporting higher with alternative methods, which were highly concordant. Accounting for misreporters with all methods yielded diet-BMI relations that were more consistent with expectations; alternative methods often strengthened associations. For example, among women, multivariable-adjusted differences in BMI for the highest versus lowest vegetable intake tertile (β = 0.37 (standard error, 0.07)) were neutral after adjusting with the original method (β = 0.01 (standard error, 07)) and negative using the predicted total energy expenditure method with stringent cutoffs (β = -0.15 (standard error, 0.07)). Alternative methods may yield more valid associations between diet and obesity-related outcomes. PMID:21242302

  4. Measurement of condensible particulate matter: A review of alternatives to EPA Method 202. Final report

    SciTech Connect

    McDannel, M.D.

    1998-09-01

    Condensible particulate matter (CPM) consists of species which are emitted from a source in the vapor phase at stack gas temperatures but condense into a liquid or solid aerosol at ambient temperatures. The US EPA method for measuring CPM (Reference Method 202) is subject to false positive biases because of conversion of non-particulate species into CPM in the test sampling train. These biases are significant for coal- and oil-fired boilers, and can often be larger than actual particulate emissions and/or emission limits. In response to these issues, the Electric Power Research Institute (EPRI) retained Fossil Energy Research Corporation (FERCo) to conduct a study to evaluate Method 202 and develop and test alternatives to the method which would eliminate the bias. The program included three phases: (1) a review of technical and regulatory issues related to CPM measurements, (2) evaluation of a variety of possible modifications and alternatives to Method 202, and (3) full scale field testing of two alternatives, the use of reduced filtration temperature with correction for sulfuric acid pseudoparticulate, and use of isopropanol rather than water impingers to collect CPM. This State of the Art Report presents a summary of the current state of CPM measurement from technical and regulatory perspectives, the results of the bench scale and full scale evaluation programs, and recommendations for further field evaluation and for gaining EPA approval of an alternative method that eliminates the positive bias.

  5. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral...-1 Approved methods of grounding of equipment receiving power from ungrounded alternating current... receiving power from ungrounded alternating current power systems, the following methods of grounding...

  6. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral...-1 Approved methods of grounding of equipment receiving power from ungrounded alternating current... receiving power from ungrounded alternating current power systems, the following methods of grounding...

  7. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral...-1 Approved methods of grounding of equipment receiving power from ungrounded alternating current... receiving power from ungrounded alternating current power systems, the following methods of grounding...

  8. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral...-1 Approved methods of grounding of equipment receiving power from ungrounded alternating current... receiving power from ungrounded alternating current power systems, the following methods of grounding...

  9. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral...-1 Approved methods of grounding of equipment receiving power from ungrounded alternating current... receiving power from ungrounded alternating current power systems, the following methods of grounding...

  10. Update from the Japanese Center for the Validation of Alternative Methods (JaCVAM).

    PubMed

    Kojima, Hajime

    2013-12-01

    The Japanese Center for the Validation of Alternative Methods (JaCVAM) was established in 2005 to promote the use of alternatives to animal testing in regulatory studies, thereby replacing, reducing, or refining the use of animals, according to the Three Rs principles. JaCVAM assesses the utility, limitations and suitability for use in regulatory studies, of test methods needed to determine the safety of chemicals and other materials. JaCVAM also organises and performs validation studies of new test methods, when necessary. In addition, JaCVAM co-operates and collaborates with similar organisations in related fields, both in Japan and internationally, which also enables JaCVAM to provide input during the establishment of guidelines for new alternative experimental methods. These activities help facilitate application and approval processes for the manufacture and sale of pharmaceuticals, chemicals, pesticides, and other products, as well as for revisions to standards for cosmetic products. In this manner, JaCVAM plays a leadership role in the introduction of new alternative experimental methods for regulatory acceptance in Japan. PMID:24512226

  11. An alternative method using microwave power saturate in fingernail/electron paramagnetic resonance dosimetry.

    PubMed

    Choi, Hoon; Park, Byeongryong; Choi, Muhyun; Lee, Byungil; Lee, Cheol Eui

    2014-06-01

    An alternative method for fingernail/electron paramagnetic resonance (EPR) dosimetry valid at low doses (0-3 Gy) is suggested in this paper. The method consisted of two steps. The first step involved dehydrating fingernail clippings to remove their water content by heating them at 70 °C for 72 h. As the water content in the fingernails decreased, the variability of the EPR signals improved. The second step involved measuring and fitting the EPR signals at successive microwave power levels. A newly derived value known as 'curvature', which was based on the conventional peak-to-peak amplitudes of the EPR signals, was applied for the dosimetry. This method could be used as an alternative method in cases of low-radiation exposure doses (<3 Gy) or where use of the conventional dosimetry method is not proper for a fingernail sample. PMID:24876339

  12. Attributed Goal-Oriented Analysis Method for Selecting Alternatives of Software Requirements

    NASA Astrophysics Data System (ADS)

    Yamamoto, Kazuma; Saeki, Motoshi

    During software requirements analysis, developers and stakeholders have many alternatives of requirements to be achieved and should make decisions to select an alternative out of them. There are two significant points to be considered for supporting these decision making processes in requirements analysis; 1) dependencies among alternatives and 2) evaluation based on multi-criteria and their trade-off. This paper proposes the technique to address the above two issues by using an extended version of goal-oriented analysis. In goal-oriented analysis, elicited goals and their dependencies are represented with an AND-OR acyclic directed graph. We use this technique to model the dependencies of the alternatives. Furthermore we associate attribute values and their propagation rules with nodes and edges in a goal graph in order to evaluate the alternatives with them. The attributes and their calculation rules greatly depend on the characteristics of a development project. Thus, in our approach, we select and use the attributes and their rules that can be appropriate for the project. TOPSIS method is adopted to show alternatives and their resulting attribute values.

  13. An ultrasonic method for determination of elastic moduli, density, attenuation and thickness of a polymer coating on a stiff plate.

    PubMed

    Lavrentyev, A I; Rokhlin, S I

    2001-04-01

    An ultrasonic method proposed by us for determination of the complete set of acoustical and geometrical properties of a thin isotropic layer between semispaces (J. Acoust. Soc. Am. 102 (1997) 3467) is extended to determination of the properties of a coating on a thin plate. The method allows simultaneous determination of the coating thickness, density, elastic moduli and attenuation (longitudinal and shear) from normal and oblique incidence reflection (transmission) frequency spectra. Reflection (transmission) from the coated plate is represented as a function of six nondimensional parameters of the coating which are determined from two experimentally measured spectra: one at normal and one at oblique incidence. The introduction of the set of nondimensional parameters allows one to transform the reconstruction process from one search in a six-dimensional space to two searches in three-dimensional spaces (one search for normal incidence and one for oblique). Thickness, density, and longitudinal and shear elastic moduli of the coating are calculated from the nondimensional parameters determined. The sensitivity of the method to individual properties and its stability against experimental noise are studied and the inversion algorithm is accordingly optimized. An example of the method and experimental measurement for comparison is given for a polypropylene coating on a steel foil. PMID:11350002

  14. An Evaluation Method for the Suppression of Pathogenic Fusarium oxysporum by Soil Microorganisms Using the Dilution Plate Technique

    PubMed Central

    Mitsuboshi, Masahiro; Kioka, Yuuzou; Noguchi, Katsunori; Asakawa, Susumu

    2016-01-01

    Soil-borne diseases caused by pathogenic microorganisms are one of the main factors responsible for the decline in crop yields in farmlands. Pathogenic Fusarium oxysporum causes serious damage to various crops, and, thus, a feasible diagnostic method for soil-borne diseases is required. We herein examined a simple method to evaluate the suppressiveness of soil microorganisms against a pathogen by co-cultivating indigenous soil microorganisms and a pathogenic fungus (F. oxysporum f. sp. spinaciae). We inoculated F. oxysporum onto the center of agar medium plates mixed with a dilution series of a suspension of organic fertilizers or soil. After an approximately one-week cultivation, the growth degree of F. oxysporum was estimated based on the size of the colonies that formed on the plates. The growth degree of F. oxysporum significantly differed among the organic fertilizers tested, indicating the usefulness of the method for evaluating suppressiveness by organic fertilizers. Differences in the growth degrees of F. oxysporum were associated with the incidence of disease in spinach on soil treated with organic fertilizers and inoculated with a pathogenic F. oxysporum strain. These results suggested that this method provides some useful information on the suppressiveness of organic fertilizers and soil against Fusarium wilt. PMID:27558588

  15. Alternative conceptions of introductory geoscience students and a method to decrease them

    NASA Astrophysics Data System (ADS)

    Kortz, Karen Melissa

    College students often leave introductory geoscience courses with alternative conceptions, and these alternative conceptions are a barrier to their grasp of geological conceptions. This dissertation clarifies the problem and suggests pedagogical strategies for correcting it. It is an integration of research on students' conceptions of geoscience topics with the application of that knowledge to the development of materials to change these conceptions to be more scientifically accurate. This research identifies and documents alternative conceptions students have in several key geoscience topics and the consequences of these alternative conception in terms of preventing understanding. After documenting the alternative conceptions, I investigate their sources. In addition, I develop ways in which the alternative conceptions can be addressed in classrooms in terms of non-traditional teaching techniques, and I assess the success of these methods. Chapter 1 addresses alternative conceptions in general introductory geoscience topics. I use known student alternative conceptions to develop a series of interactive materials to help reduce students' alternative conceptions. After their development, I assess the efficacy of these materials, and my research indicates that they are successful in helping students better learn the geoscience concepts. Chapter 2 deals with a particularly difficult topic for students---that of phylogenetic systematics. Students have an intuitive way of categorizing organisms, and this categorization is different from the system used by experts within the field. My investigation indicates the conceptual change required of students to fully understand the topic leads to great difficulties with learning. Drawing upon results of the research in Chapter 1, I developed and assessed interactive materials to help students better understand phylogenetic systematics. Using the insight gained from Chapters 1 and 2, Chapters 3 and 4 further examine students

  16. Fracture Toughness of Thin Plates by the Double-Torsion Test Method

    NASA Technical Reports Server (NTRS)

    Salem, Jonathan A.; Radovic, Miladin; Lara-Curzio, Edgar; Nelson, George

    2006-01-01

    Double torsion testing can produce fracture toughness values without crack length measurement that are comparable to those measured via standardized techniques such as the chevron-notch, surface-crack-in-flexure and precracked beam if the appropriate geometry is employed, and the material does not exhibit increasing crack growth resistance. Results to date indicate that 8 < W/d < 80 and L/W > 2 are required if crack length is not considered in stress intensity calculations. At L/W = 2, the normalized crack length should be 0.35 < a/L < 0.65; whereas for L/W = 3, 0.2 < a/L < 0.75 is acceptable. In addition, the load-points need to roll to reduce friction. For an alumina exhibiting increasing crack growth resistance, values corresponding to the plateau of the R-curve were measured. For very thin plates (W/d > 80) nonlinear effects were encountered.

  17. Alternating Renewal Process Models for Behavioral Observation: Simulation Methods, Software, and Validity Illustrations

    ERIC Educational Resources Information Center

    Pustejovsky, James E.; Runyon, Christopher

    2014-01-01

    Direct observation recording procedures produce reductive summary measurements of an underlying stream of behavior. Previous methodological studies of these recording procedures have employed simulation methods for generating random behavior streams, many of which amount to special cases of a statistical model known as the alternating renewal…

  18. 40 CFR 211.206-3-211.206-10 - Alternative test methods. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Alternative test methods. 211.206-3-211.206-10 Section 211.206-3-211.206-10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices §§...

  19. 40 CFR 211.206-3-211.206-10 - Alternative test methods. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Alternative test methods. 211.206-3-211.206-10 Section 211.206-3-211.206-10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices §§...

  20. 30 CFR 250.1504 - May I use alternative training methods?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false May I use alternative training methods? 250.1504 Section 250.1504 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Well Control and...

  1. 75 FR 7593 - Recent Postings of Broadly Applicable Alternative Test Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-22

    ... 72 FR 4257 (January 30, 2007) and found on the EPA's Web site at http://www.epa.gov/ttn/emc/approalt... alternative test methods are outlined at 72 FR 4257 (January 30, 2007). EPA will continue to announce... Determination of Metal CFR part 63, subpart hydrochloric acid in Emissions from EEE, National the digestate...

  2. Accelerating the Use of Weblogs as an Alternative Method to Deliver Case-Based Learning

    ERIC Educational Resources Information Center

    Chen, Charlie; Wu, Jiinpo; Yang, Samuel C.

    2008-01-01

    Weblog technology is an alternative medium to deliver the case-based method of learning business concepts. The social nature of this technology can potentially promote active learning and enhance analytical ability of students. The present research investigates the primary factors contributing to the adoption of Weblog technology by students to…

  3. 48 CFR 48.104-4 - Sharing alternative-no-cost settlement method.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Sharing alternative-no-cost settlement method. 48.104-4 Section 48.104-4 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT VALUE ENGINEERING Policies and Procedures 48.104-4...

  4. 48 CFR 48.104-4 - Sharing alternative-no-cost settlement method.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Sharing alternative-no-cost settlement method. 48.104-4 Section 48.104-4 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT VALUE ENGINEERING Policies and Procedures 48.104-4...

  5. 48 CFR 48.104-4 - Sharing alternative-no-cost settlement method.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Sharing alternative-no-cost settlement method. 48.104-4 Section 48.104-4 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT VALUE ENGINEERING Policies and Procedures 48.104-4...

  6. 48 CFR 48.104-4 - Sharing alternative-no-cost settlement method.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Sharing alternative-no-cost settlement method. 48.104-4 Section 48.104-4 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT VALUE ENGINEERING Policies and Procedures 48.104-4...

  7. 29 CFR 2520.104-4 - Alternative method of compliance for certain successor pension plans.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pension plans. 2520.104-4 Section 2520.104-4 Labor Regulations Relating to Labor (Continued) EMPLOYEE... certain successor pension plans. (a) General. Under the authority of section 110 of the Act, this section sets forth an alternative method of compliance for certain successor pension plans in which...

  8. 29 CFR 2520.104-4 - Alternative method of compliance for certain successor pension plans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pension plans. 2520.104-4 Section 2520.104-4 Labor Regulations Relating to Labor (Continued) EMPLOYEE... certain successor pension plans. (a) General. Under the authority of section 110 of the Act, this section sets forth an alternative method of compliance for certain successor pension plans in which...

  9. 30 CFR 553.32 - Are there alternative methods to demonstrate OSFR?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Director's sole discretion and is not subject to administrative appeal under 30 CFR part 590 or 43 CFR part... 30 Mineral Resources 2 2013-07-01 2013-07-01 false Are there alternative methods to demonstrate OSFR? 553.32 Section 553.32 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF...

  10. 30 CFR 253.32 - Are there alternative methods to demonstrate OSFR?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... appeal under 30 CFR part 290 or 43 CFR part 4. ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Are there alternative methods to demonstrate OSFR? 253.32 Section 253.32 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION,...

  11. 30 CFR 553.32 - Are there alternative methods to demonstrate OSFR?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Director's sole discretion and is not subject to administrative appeal under 30 CFR part 590 or 43 CFR part... 30 Mineral Resources 2 2014-07-01 2014-07-01 false Are there alternative methods to demonstrate OSFR? 553.32 Section 553.32 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF...

  12. 30 CFR 553.32 - Are there alternative methods to demonstrate OSFR?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Director's sole discretion and is not subject to administrative appeal under 30 CFR part 590 or 43 CFR part... 30 Mineral Resources 2 2012-07-01 2012-07-01 false Are there alternative methods to demonstrate OSFR? 553.32 Section 553.32 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF...

  13. Alternative Assessment Methods Based on Categorizations, Supporting Technologies, and a Model for Betterment

    ERIC Educational Resources Information Center

    Ben-Jacob, Marion G.; Ben-Jacob, Tyler E.

    2014-01-01

    This paper explores alternative assessment methods from the perspective of categorizations. It addresses the technologies that support assessment. It discusses initial, formative, and summative assessment, as well as objective and subjective assessment, and formal and informal assessment. It approaches each category of assessment from the…

  14. 29 CFR 4010.12 - Alternative method of compliance for certain sponsors of multiple employer plans.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Alternative method of compliance for certain sponsors of multiple employer plans. 4010.12 Section 4010.12 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION CERTAIN REPORTING AND DISCLOSURE REQUIREMENTS ANNUAL FINANCIAL AND...

  15. 29 CFR 4010.12 - Alternative method of compliance for certain sponsors of multiple employer plans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Alternative method of compliance for certain sponsors of multiple employer plans. 4010.12 Section 4010.12 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION CERTAIN REPORTING AND DISCLOSURE REQUIREMENTS ANNUAL FINANCIAL AND...

  16. 29 CFR 4010.12 - Alternative method of compliance for certain sponsors of multiple employer plans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Alternative method of compliance for certain sponsors of multiple employer plans. 4010.12 Section 4010.12 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION CERTAIN REPORTING AND DISCLOSURE REQUIREMENTS ANNUAL FINANCIAL AND...

  17. 29 CFR 4010.12 - Alternative method of compliance for certain sponsors of multiple employer plans.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Alternative method of compliance for certain sponsors of multiple employer plans. 4010.12 Section 4010.12 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION CERTAIN REPORTING AND DISCLOSURE REQUIREMENTS ANNUAL FINANCIAL AND...

  18. 77 FR 8865 - Recent Postings of Broadly Applicable Alternative Test Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-15

    ... 72 FR 4257 (January 30, 2007) and found on the EPA's Web site at www.epa.gov/ttn/emc/approalt.html... outlined at 72 FR 4257 (January 30, 2007). We will continue to announce approvals for broadly applicable... AGENCY Recent Postings of Broadly Applicable Alternative Test Methods AGENCY: Environmental...

  19. Communicative Approach: An Alternative Method Used in Improving Students' Academic Reading Achievement

    ERIC Educational Resources Information Center

    Irmawati, Noer Doddy

    2012-01-01

    Academic reading is a difficult subject to be mastered. It is needed because most of books or references are written in English. The emphasis is on academic reading which becomes a compulsory subject that must be taught and understood in Faculty of Letters UAD Yogyakarta. Communicative approach is used and applied as an alternative method in the…

  20. Report to the Congress on alternative methods for the Strategic Petroleum Reserve

    SciTech Connect

    Not Available

    1990-02-01

    The purpose of this study is to fulfill the requirements of Public Law No. 101-46, approved June 30, 1989. The study describes and evaluates alternative methods for financing the future expansion of the Strategic petroleum Reserve (SPR), both to the current target level of 750 million barrels and to potential future levels of up to one billion barrels.

  1. Table or Circles: A Comparison of Two Methods for Choosing among Career Alternatives

    ERIC Educational Resources Information Center

    Amit, Adi; Gati, Itamar

    2013-01-01

    A sample of 182 young adults about to choose their college major were randomly assigned to 2 guidance methods aimed at facilitating choosing among promising career alternatives: Table-for-Choice and Circles-for-Choice. Table-for-Choice was perceived as more effective, but individuals' confidence in their choice was higher in the Circles-for-Choice…

  2. 77 FR 11536 - Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-27

    ... FR 45254). In accordance with the ICCVAM Authorization Act of 2000 (42 U.S.C. 285l-3), agencies have... comment in May 2008 (73 FR 29136). The Scientific Advisory Committee on Alternative Toxicological Methods... 2008 meeting (73 FR 25754). ICCVAM considered the panel's report, comments from SACATM, and...

  3. 27 CFR 478.22 - Alternate methods or procedures; emergency variations from requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Alternate methods or procedures; emergency variations from requirements. 478.22 Section 478.22 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS...

  4. 27 CFR 20.22 - Alternate methods or procedures; and emergency variations from requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures; and emergency variations from requirements. 20.22 Section 20.22 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND...

  5. 27 CFR 555.22 - Alternate methods or procedures; emergency variations from requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Alternate methods or procedures; emergency variations from requirements. 555.22 Section 555.22 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE EXPLOSIVES COMMERCE...

  6. 27 CFR 22.22 - Alternate methods or procedures; and emergency variations from requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures; and emergency variations from requirements. 22.22 Section 22.22 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND...

  7. 27 CFR 479.26 - Alternate methods or procedures; emergency variations from requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Alternate methods or procedures; emergency variations from requirements. 479.26 Section 479.26 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS...

  8. 27 CFR 28.20 - Alternate methods or procedures; and emergency variations from requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alternate methods or procedures; and emergency variations from requirements. 28.20 Section 28.20 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS EXPORTATION...

  9. Component mode synthesis and large deflection vibration of complex structures. Volume 2: Single-mode large deflection vibrations of beams and plates using finite element method

    NASA Technical Reports Server (NTRS)

    Mei, Chuh

    1987-01-01

    A finite element method is presented for the large amplitude vibrations of complex structures that can be modelled with beam and rectangular plate elements subjected to harmonic excitation. Both inplane deformation and inertia are considered in the formulation. Derivation of the harmonic force and nonlinear stiffness matrices for a beam and a rectangular plate element are presented. Solution procedures and convergence characteristics of the finite element method are described. Nonlinear response to uniform and concentrated harmonic loadings and improved nonlinear free vibration results are presented for beams and rectangular plates of various boundary conditions.

  10. 40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... validated according to the procedures in Sections 5.1 and 5.3 of Test Method 301, 40 CFR part 63, appendix A... Method 25D of 40 CFR part 60, appendix A. 2.1. Sampling and Analysis 2.1.1. For each waste matrix... 40 Protection of Environment 14 2011-07-01 2011-07-01 false Alternative Validation Procedure...

  11. An evaluation of alternative cleaning methods for removing an organic contaminant from a stainless steel part

    SciTech Connect

    Boyd, J.L.

    1996-08-01

    As of December 1995, the manufacture of Freon, along with many other chlorofluorocarbons (CFCs), was prohibited by the Clean Air Act of 1990 (CAA). The ban of CFC solvents has forced manufacturers across the country to search for alternative metal cleaning techniques. The objective of this study was to develop a thorough, scientific based approach for resolving one specific manufacturer`s problem of removing organic contamination from a stainless steel part. This objective was accomplished with an approach that involved: (1) defining the problem, (2) identifying the process constraints, (3) researching alternate cleaning methods, (4) researching applicable government regulations, (5) performing a scientific evaluation and (6) drawing conclusions.

  12. An alternative method for modeling the size distribution of top wealth

    NASA Astrophysics Data System (ADS)

    Wang, Yuanjun; You, Shibing

    2016-09-01

    The Pareto distribution has been widely applied in modeling the distribution of wealth, as well as top incomes, cities and firms. However, recent evidence has shown that the Pareto distribution is not consistent with many situations in which it was previously considered applicable. We propose an alternative method for estimating the upper tail distribution of wealth and suggest a new Lorenz curve for building models to provide such estimates. Applying our new models to the Forbes World's Billionaire Lists, we show that they significantly outperform the Pareto Lorenz curve as well as some other popular alternatives.

  13. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  14. Use of Biosensors as Alternatives to Current Regulatory Methods for Marine Biotoxins

    PubMed Central

    Vilariño, Natalia; Fonfría, Eva S.; Louzao, M. Carmen; Botana, Luis M.

    2009-01-01

    Marine toxins are currently monitored by means of a bioassay that requires the use of many mice, which poses a technical and ethical problem in many countries. With the exception of domoic acid, there is a legal requirement for the presence of other toxins (yessotoxin, saxitoxin and analogs, okadaic acid and analogs, pectenotoxins and azaspiracids) in seafood to be controlled by bioassay, but other toxins, such as palytoxin, cyclic imines, ciguatera and tetrodotoxin are potentially present in European food and there are no legal requirements or technical approaches available to identify their presence. The need for alternative methods to the bioassay is clearly important, and biosensors have become in recent years a feasible alternative to animal sacrifice. This review will discuss the advantages and disadvantages of using biosensors as alternatives to animal assays for marine toxins, with particular focus on surface plasmon resonance (SPR) technology. PMID:22291571

  15. A novel computational method for the identification of plant alternative splice sites.

    PubMed

    Cui, Ying; Han, Jiuqiang; Zhong, Dexing; Liu, Ruiling

    2013-02-01

    Alternative splicing (AS) increases protein diversity by generating multiple transcript isoforms from a single gene in higher eukaryotes. Up to 48% of plant genes exhibit alternative splicing, which has proven to be involved in some important plant functions such as the stress response. A hybrid feature extraction approach which combing the position weight matrix (PWM) with the increment of diversity (ID) was proposed to represent the base conservative level (BCL) near splice sites and the similarity level of two datasets, respectively. Using the extracted features, the support vector machine (SVM) was applied to classify alternative and constitutive splice sites. By the proposed algorithm, 80.8% of donor sites and 85.4% of acceptor sites were correctly classified. It is anticipated that the novel computational method is promising for the identification of AS sites in plants. PMID:23313482

  16. An evaluation of alternate production methods for Pu-238 general purpose heat source pellets

    SciTech Connect

    Mark Borland; Steve Frank

    2009-06-01

    For the past half century, the National Aeronautics and Space Administration (NASA) has used Radioisotope Thermoelectric Generators (RTG) to power deep space satellites. Fabricating heat sources for RTGs, specifically General Purpose Heat Sources (GPHSs), has remained essentially unchanged since their development in the 1970s. Meanwhile, 30 years of technological advancements have been made in the applicable fields of chemistry, manufacturing and control systems. This paper evaluates alternative processes that could be used to produce Pu 238 fueled heat sources. Specifically, this paper discusses the production of the plutonium-oxide granules, which are the input stream to the ceramic pressing and sintering processes. Alternate chemical processes are compared to current methods to determine if alternative fabrication processes could reduce the hazards, especially the production of respirable fines, while producing an equivalent GPHS product.

  17. Method for exploiting bias in factor analysis using constrained alternating least squares algorithms

    DOEpatents

    Keenan, Michael R.

    2008-12-30

    Bias plays an important role in factor analysis and is often implicitly made use of, for example, to constrain solutions to factors that conform to physical reality. However, when components are collinear, a large range of solutions may exist that satisfy the basic constraints and fit the data equally well. In such cases, the introduction of mathematical bias through the application of constraints may select solutions that are less than optimal. The biased alternating least squares algorithm of the present invention can offset mathematical bias introduced by constraints in the standard alternating least squares analysis to achieve factor solutions that are most consistent with physical reality. In addition, these methods can be used to explicitly exploit bias to provide alternative views and provide additional insights into spectral data sets.

  18. Comprehensive exon array data processing method for quantitative analysis of alternative spliced variants

    PubMed Central

    Chen, Ping; Lepikhova, Tatiana; Hu, Yizhou; Monni, Outi; Hautaniemi, Sampsa

    2011-01-01

    Alternative splicing of pre-mRNA generates protein diversity. Dysfunction of splicing machinery and expression of specific transcripts has been linked to cancer progression and drug response. Exon microarray technology enables genome-wide quantification of expression levels of the majority of exons and facilitates the discovery of alternative splicing events. Analysis of exon array data is more challenging than the analysis of gene expression data and there is a need for reliable quantification of exons and alternatively spliced variants. We introduce a novel, computationally efficient methodology, Multiple Exon Array Preprocessing (MEAP), for exon array data pre-processing, analysis and visualization. We compared MEAP with existing pre-processing methods, and validation of six exons and two alternatively spliced variants with qPCR corroborated MEAP expression estimates. Analysis of exon array data from head and neck squamous cell carcinoma (HNSCC) cell lines revealed several transcripts associated with 11q13 amplification, which is related with decreased survival and metastasis in HNSCC patients. Our results demonstrate that MEAP produces reliable expression values at exon, alternatively spliced variant and gene levels, which allows generating novel experimentally testable predictions. PMID:21745820

  19. Alternative methods for dispoal of low-level radioactive wastes. Task 1. Description of methods and assessment of criteria. [Alternative methods are belowground vaults, aboveground vaults; earth mounded concrete bunkers, mined cavities, augered holes

    SciTech Connect

    Bennett, R.D.; Miller, W.O.; Warriner, J.B.; Malone, P.G.; McAneny, C.C.

    1984-04-01

    The study reported herein contains the results of Task 1 of a four-task study entitled Criteria for Evaluating Engineered Facilities. The overall objective of this study is to ensure that the criteria needed to evaluate five alternative low-level radioactive waste (LLW) disposal methods are available to the Nuclear Regulatory Commission (NRC) and the Agreement States. The alternative methods considered are belowground vaults, aboveground vaults, earth mounded concrete bunkers, mined cavities, and augered holes. Each of these alternatives is either being used by other countries for low-level radioactive waste (LLW) disposal or is being considered by other countries or US agencies. In this report the performance requirements are listed, each alternative is described, the experience gained with its use is discussed, and the performance capabilities of each method are addressed. Next, the existing 10 CFR Part 61 Subpart D criteria with respect to paragraphs 61.50 through 61.53, pertaining to site suitability, design, operations and closure, and monitoring are assessed for applicability to evaluation of each alternative. Preliminary conclusions and recommendations are offered on each method's suitability as an LLW disposal alternative, the applicability of the criteria, and the need for supplemental or modified criteria.

  20. Simulative method for determining the optimal operating conditions for a cooling plate for lithium-ion battery cell modules

    NASA Astrophysics Data System (ADS)

    Smith, Joshua; Hinterberger, Michael; Hable, Peter; Koehler, Juergen

    2014-12-01

    Extended battery system lifetime and reduced costs are essential to the success of electric vehicles. An effective thermal management strategy is one method of enhancing system lifetime increasing vehicle range. Vehicle-typical space restrictions favor the minimization of battery thermal management system (BTMS) size and weight, making their production and subsequent vehicle integration extremely difficult and complex. Due to these space requirements, a cooling plate as part of a water-glycerol cooling circuit is commonly implemented. This paper presents a computational fluid dynamics (CFD) model and multi-objective analysis technique for determining the thermal effect of coolant flow rate and inlet temperature in a cooling plate-at a range of vehicle operating conditions-on a battery system, thereby providing a dynamic input for one-dimensional models. Traditionally, one-dimensional vehicular thermal management system models assume a static heat input from components such as a battery system: as a result, the components are designed for a set coolant input (flow rate and inlet temperature). Such a design method is insufficient for dynamic thermal management models and control strategies, thereby compromising system efficiency. The presented approach allows for optimal BMTS design and integration in the vehicular coolant circuit.

  1. Consensus methods: review of original methods and their main alternatives used in public health

    PubMed Central

    Bourrée, Fanny; Michel, Philippe; Salmi, Louis Rachid

    2008-01-01

    Summary Background Consensus-based studies are increasingly used as decision-making methods, for they have lower production cost than other methods (observation, experimentation, modelling) and provide results more rapidly. The objective of this paper is to describe the principles and methods of the four main methods, Delphi, nominal group, consensus development conference and RAND/UCLA, their use as it appears in peer-reviewed publications and validation studies published in the healthcare literature. Methods A bibliographic search was performed in Pubmed/MEDLINE, Banque de Données Santé Publique (BDSP), The Cochrane Library, Pascal and Francis. Keywords, headings and qualifiers corresponding to a list of terms and expressions related to the consensus methods were searched in the thesauri, and used in the literature search. A search with the same terms and expressions was performed on Internet using the website Google Scholar. Results All methods, precisely described in the literature, are based on common basic principles such as definition of subject, selection of experts, and direct or remote interaction processes. They sometimes use quantitative assessment for ranking items. Numerous variants of these methods have been described. Few validation studies have been implemented. Not implementing these basic principles and failing to describe the methods used to reach the consensus were both frequent reasons contributing to raise suspicion regarding the validity of consensus methods. Conclusion When it is applied to a new domain with important consequences in terms of decision making, a consensus method should be first validated. PMID:19013039

  2. Identifying alternative linkages among philosophy, theory and method in nursing science.

    PubMed

    Kim, H S

    1993-05-01

    The major concerns expressed in the literature regarding the development and expansion of nursing science stem from questions related to 'what sorts of science' and 'which scientific methods' are appropriate for nursing. While there is a sector of nursing's scientific community that advocates a unified approach to philosophy and method, a growing sentiment for the position of philosophical and methodological pluralism is apparent. This paper addresses the nature of scientific pluralism by presenting a framework for alternative linkages possible among the philosophy, theory and method appropriate for nursing science. The nature of nursing knowledge that is produced within the discipline will thus depend on various forms of alternative linkages adopted by nursing scientists in addressing nursing's scientific questions. In turn, such pluralism presents problems of choice to nurses in practice with respect to knowledge utilization. PMID:8514936

  3. Parents’ attitude toward multiple vaccinations at a single visit with alternative delivery methods

    PubMed Central

    Kaaijk, Patricia; Kleijne, Deborah E; Knol, Mirjam J; Harmsen, Irene A; Ophorst, Olga JAE; Rots, Nynke Y

    2014-01-01

    Last decades, the number of routine childhood vaccinations has increased considerably, which consequently has led to multiple vaccine injections per consultation. Implementation of additional vaccines will probably lead to more than 2 vaccine injections per consult, which might be a barrier for parents to vaccinate their child. A decrease in vaccination coverage, however, increases the risk of disease outbreaks. Less stressful alternative methods for vaccine delivery might lead to an increased acceptance of multiple childhood vaccinations by parents. The present questionnaire study was set up to explore the maximum number of vaccine injections per visit that is acceptable for parents, as well as to gauge parents’ attitude toward alternative needle-free methods for vaccine delivery. For this purpose, the parents’ opinion toward a jet injector, a patch, a microneedle system, and nasal spray device as methods for vaccine delivery was assessed. The majority of the 1154 participating parents indicated that 3 vaccine injections per visit was perceived as too much. Most participants had a positive attitude with respect to the jet injector and the patch as alternative vaccine delivery method, whereas the microneedle device and an intranasal spray device were not perceived as better than the conventional syringe by the parents. Parents indicated that both the jet injector and the patch might increase their acceptance of giving their children more than 2 vaccinations at the same time. This should encourage vaccine developers and manufacturers to put efforts in developing these delivery methods for their vaccines. PMID:25424960

  4. A Pressure Plate-Based Method for the Automatic Assessment of Foot Strike Patterns During Running.

    PubMed

    Santuz, Alessandro; Ekizos, Antonis; Arampatzis, Adamantios

    2016-05-01

    The foot strike pattern (FSP, description of how the foot touches the ground at impact) is recognized to be a predictor of both performance and injury risk. The objective of the current investigation was to validate an original foot strike pattern assessment technique based on the numerical analysis of foot pressure distribution. We analyzed the strike patterns during running of 145 healthy men and women (85 male, 60 female). The participants ran on a treadmill with integrated pressure plate at three different speeds: preferred (shod and barefoot 2.8 ± 0.4 m/s), faster (shod 3.5 ± 0.6 m/s) and slower (shod 2.3 ± 0.3 m/s). A custom-designed algorithm allowed the automatic footprint recognition and FSP evaluation. Incomplete footprints were simultaneously identified and corrected from the software itself. The widely used technique of analyzing high-speed video recordings was checked for its reliability and has been used to validate the numerical technique. The automatic numerical approach showed a good conformity with the reference video-based technique (ICC = 0.93, p < 0.01). The great improvement in data throughput and the increased completeness of results allow the use of this software as a powerful feedback tool in a simple experimental setup. PMID:26471786

  5. Simple method for the analysis of food dyes on reversed-phase thin-layer plates.

    PubMed

    Oka, H; Ikai, Y; Kawamura, N; Yamada, M; Inoue, H; Ohno, T; Inagaki, K; Kuno, A; Yamamoto, N

    1987-12-18

    A technique for the determination of food dyes using reversed-phase thin-layer chromatography on octadecyl-modified silica is described. A solvent system containing 5.0% aqueous sodium sulphate solution enables good separation of the food dyes. Their separation is dependent on the pH of the solvent system, good separation among all dyes being obtained between pH 6.0 and 7.0. The determination of thirteen dyes can be achieved by a combination of methanol-acetonitrile-5.0% aqueous sodium sulphate solution (3:3:10) (solvent system A) and methanol-methyl ethyl ketone-5.0% aqueous sodium sulphate solution (1:1:1) (solvent system B). Solvent system A was used for the determination of Tartrazine, Amaranth, Indigo Carmine, New Coccine, Sunset Yellow FCF, Allura Red AC, Fast Green FCF and Brilliant Blue FCF and for the screening of Acid Red (R-106), Eosin (R-103), Erythrosin (R-3), Rose Bengale (R-105) and Phloxine (R-104). When the spots of R-3, R-103, R-104, R-105 and R-106 appear on the plate, their determination can be achieved by using solvent system B. Each calibration graph was linear between 0.2 and 1.0 micrograms. PMID:3443633

  6. Testing alternative ground water models using cross-validation and other methods

    USGS Publications Warehouse

    Foglia, L.; Mehl, S.W.; Hill, M.C.; Perona, P.; Burlando, P.

    2007-01-01

    Many methods can be used to test alternative ground water models. Of concern in this work are methods able to (1) rank alternative models (also called model discrimination) and (2) identify observations important to parameter estimates and predictions (equivalent to the purpose served by some types of sensitivity analysis). Some of the measures investigated are computationally efficient; others are computationally demanding. The latter are generally needed to account for model nonlinearity. The efficient model discrimination methods investigated include the information criteria: the corrected Akaike information criterion, Bayesian information criterion, and generalized cross-validation. The efficient sensitivity analysis measures used are dimensionless scaled sensitivity (DSS), composite scaled sensitivity, and parameter correlation coefficient (PCC); the other statistics are DFBETAS, Cook's D, and observation-prediction statistic. Acronyms are explained in the introduction. Cross-validation (CV) is a computationally intensive nonlinear method that is used for both model discrimination and sensitivity analysis. The methods are tested using up to five alternative parsimoniously constructed models of the ground water system of the Maggia Valley in southern Switzerland. The alternative models differ in their representation of hydraulic conductivity. A new method for graphically representing CV and sensitivity analysis results for complex models is presented and used to evaluate the utility of the efficient statistics. The results indicate that for model selection, the information criteria produce similar results at much smaller computational cost than CV. For identifying important observations, the only obviously inferior linear measure is DSS; the poor performance was expected because DSS does not include the effects of parameter correlation and PCC reveals large parameter correlations. ?? 2007 National Ground Water Association.

  7. Alternative methods for the use of non-human primates in biomedical research.

    PubMed

    Burm, Saskia M; Prins, Jan-Bas; Langermans, Jan; Bajramovic, Jeffrey J

    2014-01-01

    The experimental use of non-human primates (NHP) in Europe is tightly regulated and is only permitted when there are no alternatives available. As a result, NHP are most often used in late, pre-clinical phases of biomedical research. Although the impetus for scientists, politicians and the general public to replace, reduce and refine NHP in biomedical research is strong, the development of 3Rs technology for NHP poses specific challenges. In February 2014 a workshop on "Alternative methods for the use of NHP in biomedical research" was organized within the international exchange program of EUPRIM-Net II, a European infrastructure initiative that links biomedical primate research centers. The workshop included lectures by key scientists in the field of alternatives as well as by experts from governmental and non-governmental organizations. Furthermore, parallel sessions were organized to stimulate discussion on the challenges of advancing the use of alternative methods for NHP. Subgroups voted on four statements and together composed a list with opportunities and priorities. This report summarizes the presentations that were held, the content of the discussion sessions and concludes with recommendations on 3Rs development for NHP specifically. These include technical, conceptual as well as political topics. PMID:25058455

  8. [PHYSICAL AND MATHEMATICAL GROUNDS LANDFORMS BASIS PLATE DENTURES WHEN APPLYING THE COMPLEX METHOD OF PREVENTION OF PROSTHETIC STOMATITIS].

    PubMed

    Zverkhanovsky, A

    2016-06-01

    Objective - to develop the form of the drug reservoir to hold the vegetable oils under the basis of the prosthesis. The research was conducted on the Bench PMMA samples. The comparison group consisted of smooth plate PMMA. Two study groups were PMMA plates with grooves on one side of a square with sides of 2 mm and depth of channel - 1 mm. The third group consisted of the experimental plate with diamond-shaped notches with the same parameters. The lowest value of the stress in the plate having a rhombic grid, they are 54% less than in the smooth plate and 37% less than in the plate with a square lattice (the best strength characteristics in a rhombic plate with grille). Equivalent move from the plate with a rhombic lattice is less than an order of magnitude than that of a smooth plate and by 5.8% more than at the plate with a square lattice, which indicates good performance design plasticity with rhombic grid. Basis with the rhombic lattice on the surface has the best record on the stress-strain state in comparison with other models considered (smooth plate with a square lattice plate). PMID:27441532

  9. Comparison of methods of immobilization to enzyme-linked immunosorbent assay plates for the detection of sugar chains.

    PubMed

    Satoh, A; Fukui, E; Yoshino, S; Shinoda, M; Kojima, K; Matsumoto, I

    1999-11-15

    The immobilization of carbohydrates for solid-phase assays, including enzyme-linked immunosorbent assay (ELISA), is difficult because they are hydrophilic. We developed four new methods for the immobilization of oligosaccharides. ELISA plates were first coated with methyl vinyl ether-maleic anhydride copolymer (MMAC) and an excess of active anhydride groups was introduced. They were subsequently reacted, in four different ways, to bind oligosaccharides. In method 1, the anhydride groups were reacted with hydrazide groups, in the presence of adipic acid dihydrazide, and then coupled to the reducing ends of sugar chains by reductive amination. In method 2, the anhydride groups were reacted with p-aminophenyl glycoside obtained by reduction with p-nitrophenyl glycoside. In method 3, the anhydride groups were reacted with 1, 6-hexamethylenediamine. Aminooxy groups were coupled to the amino groups introduced and then aminooxyacetic acid with carbodiimide and ligated to oligosaccharides by oxime formation. In method 4, stereospecifically aminated oligosaccharides reacted with the anhydride groups. We compared, in solid-phase assays systems, the ability of lectins to detect oligosaccharides immobilized with either one of these four new methods or one of the two methods previously described. Detection of sugars with lectins is useful because, in most cases, they recognize sugars stereospecifically. The immobilization method should therefore be carefully selected to avoid changing the configuration and substitution in C-1. PMID:10552909

  10. A simple separation method with a microfluidic channel based on alternating current potential modulation.

    PubMed

    Noh, Hui-Bog; Chandra, Pranjal; Kim, You-Jeong; Shim, Yoon-Bo

    2012-11-20

    A simple separation and detection system based on an electrochemical potential modulated microchannel (EPMM) device was developed for the first time. The application of alternating current (AC) potential to the microfluidic separation channel walls, which were composed of screen printed carbon electrodes, resulted in the oscillation and fluctuation of analytes and in the formation of a perfect flat flow front. These events resulted in an increase in the effective concentration and in the fine separation of samples. The performance of the EPMM device was examined through the analysis of endocrine disruptors (EDs) and heavy metal ions (HMIs) as model compounds. The analytical parameters that affected the separation and detection of EDs and HMIs were studied in terms of AC amplitude, AC frequency, flow rate, buffer concentration, pH, detection potential, and temperature. The separation efficiency was evaluated through measurements of the theoretical plate number (N), the retention time, and the half-peak width. Linear calibration plots for the detection of EDs and HMIs were obtained between 0.15 and 250.0 nM (detection limit 86.4 ± 2.9 pM) and between 0.01 and 10.0 nM (detection limit 9.5 ± 0.3 pM), respectively. The new device was successfully demonstrated with authentic and real samples. PMID:23075295

  11. Data analysis for surface plate calibration

    SciTech Connect

    Burton, R.N.

    1997-08-01

    A surface plate is used to establish a reference plane used for making precision dimensional measurements. Ideally, the surface should be perfectly flat. Since it is impossible to create a perfectly flat surface, surface plate are calibrated to determine how much they deviate from a perfectly flat surface. Once a surface plate is calibrated, the user can determine if the plate is flat enough for use in a particular application. The currently accepted method of data analysis for surface plate calibration, the Moody method, does not give optimum results because of the arbitrary way in which the reference plane is chosen. The exact solution, wherein the reference plane is located in the optimum position, has been worked out and is given in a step by step procedure along with all of the necessary equations. The amount of calculation involved in a typical example proved to be prohibitive even for a computer, so an alternate solution using a least squares criterion for locating the reference plane was developed. Results were comparable with those from Moody`s method with values being smaller or greater depending on the shape of the plate.

  12. Perspectives and strategies of alternative methods used in the risk assessment of personal care products.

    PubMed

    Quantin, P; Thélu, A; Catoire, S; Ficheux, H

    2015-11-01

    Risk assessment for personal care products requires the use of alternative methods since animal testing is now totally banned. Some of these methods are effective and have been validated by the "European Union Reference Laboratory for alternatives to animal testing"; but there is still a need for development and implementation of methods for specific endpoints. In this review, we have focused on dermal risk assessment because it is the prime route of absorption and main target organ for personal care products. Within this field, various areas must be assessed: irritation, sensitisation and toxicokinetic. Personal care product behaviour after use by the consumer and potential effects on the environment are also discussed. The purpose of this review is to show evolution and the prospects of alternative methods for safety dermal assessment. Assessment strategies must be adapted to the different chemical classes of substances studied but also to the way in which they are used. Finally, experimental and theoretical technical parameters that may impact on measured effects have been identified and discussed. PMID:26184446

  13. Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening.

    PubMed

    Mata, Gardênia Márcia Silva Campos; Martins, Evandro; Machado, Solimar Gonçalves; Pinto, Maximiliano Soares; de Carvalho, Antônio Fernandes; Vanetti, Maria Cristina Dantas

    2016-01-01

    The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional method: Lateral Flow System™, in cheeses produced on laboratory scale using raw milk collected from different farms and inoculated with Listeria innocua; and VIDAS(®)-LMO, in cheese samples collected from different manufacturers in Serro, Minas Gerais, Brazil. These samples were also characterized in terms of lactic acid bacteria, coliforms and physical-chemical analysis. In the inoculated samples, L. innocua was detected by Lateral Flow System™ method with 33% false-negative and 68% accuracy results. L. innocua was only detected in the inoculated samples by the conventional method at 60-days of cheese ripening. L. monocytogenes was not detected by the conventional and the VIDAS(®)-LMO methods in cheese samples collected from different manufacturers, which impairs evaluating the performance of this alternative method. We concluded that the conventional method provided a better recovery of L. innocua throughout cheese ripening, being able to detect L. innocua at 60-day, aging period which is required by the current legislation. PMID:27268116

  14. An alternative method for cardioplegia delivery during totally endoscopic robotic surgery.

    PubMed

    Guden, Mustafa; Korkmaz, Askin A; Sagbas, Ertan; Sanisoglu, Ilhan; Akpinar, Belhhan

    2009-01-01

    The optimal technique for myocardial protection and cardioplegia delivery during totally endoscopic robotic surgery is still under evolution. Cardioplegia delivery with endovascular clamping of the aorta is a common method used for this purpose but has several disadvantages and may lead to serious complications. Here we describe an alternative cardioplegia delivery method during totally endoscopic atrial septal defect closure and mitral valve repair. The method using a transthoracic aortic clamp and an antegrade cardioplegia cannula without any thoracotomy seems to be a safe and reproducible technique, which may enhance myocardial protection and prevent some of the complications of the endoclamp technique during robotically assisted cardiac surgery. PMID:19732223

  15. Alternative exact method for random walks on finite and periodic lattices with traps

    NASA Astrophysics Data System (ADS)

    Soler, Jose M.

    1982-07-01

    An alternative general method for random walks in finite or periodic lattices with traps is presented. The method gives, in a straightforward manner and in very little computing time, the exact probability that a random walker, starting from a given site, will undergo n steps before trapping. Another version gives the probability that the walker is at any other given position after n steps. The expected walk lengths calculated for simple lattices agree exactly with those given by a previous exact method by Walsh and Kozak.

  16. Alternative methods for determination of composition and porosity in abradable materials

    SciTech Connect

    Matejicek, Jiri . E-mail: jmatejic@ipp.cas.cz; Kolman, Blahoslav; Dubsky, Jiri; Neufuss, Karel; Hopkins, Noel; Zwick, Jochen

    2006-07-15

    Materials properties and performance are governed by their composition and structure. These are commonly characterized using materialography and image analysis. However, in abradable materials, obtaining a reliable and representative sample (polished section) for this widespread technique is complicated by their abradable nature and heterogeneity. Therefore, alternative methods are also considered in this paper. They are namely X-ray diffraction and electron probe microanalysis to determine the composition, and mercury intrusion porosimetry, Archimedean porosimetry and helium pycnometry to determine the porosity. These methods, including materialography, were applied on representative abradable materials produced by plasma spraying; their results are compared and the advantages and drawbacks of each method are discussed.

  17. An extension of A-stability to alternating direction implicit methods

    NASA Technical Reports Server (NTRS)

    Warming, R. F.; Beam, R. M.

    1978-01-01

    An alternating direction implicit (ADI) scheme was constructed by the method of approximate factorization. An A-stable linear multistep method (LMM) was used to integrate a model two-dimensional hyperbolic-parabolic partial differential equation. Sufficient conditions for the A-stability of the LMM were determined by applying the theory of positive real functions to reduce the stability analysis of the partial differential equations to a simple algebraic test. A linear test equation for partial differential equations is defined and then used to analyze the stability of approximate factorization schemes. An ADI method for the three-dimensional heat equation is also presented.

  18. Plate-like SrFe12O19 particles prepared by modified sol-gel method

    NASA Astrophysics Data System (ADS)

    Sapoletova, Nina A.; Kushnir, Sergey E.; Li, Yong Hui; An, Sung Yong; Seo, Jung-wook; Hur, Kang Heon

    2015-09-01

    M-type strontium hexaferrite powders were synthesized by the modified sol-gel method with calcination in NaCl matrix in a temperature range 790-850 °C for 1 h. X-ray diffraction analysis shows the formation of pure M-type strontium hexaferrite phase. The SrFe12O19 particles have a plate-like shape with a mean diameter 130-185 nm and a thickness 45-55 nm. The prepared powders show a saturation magnetization 70-72 emu/g and a coercive force 6.0-6.4 kOe. The suggested synthesis method combines simplicity, using of low calcination temperatures and allows to synthesize pure strontium hexaferrite powders with excellent hard magnetic properties.

  19. Application of laser ranging and VLBI data to a study of plate tectonic driving forces. [finite element method

    NASA Technical Reports Server (NTRS)

    Solomon, S. C.

    1980-01-01

    The measurability of changes in plate driving or resistive forces associated with plate boundary earthquakes by laser rangefinding or VLBI is considered with emphasis on those aspects of plate forces that can be characterized by such measurements. Topics covered include: (1) analytic solutions for two dimensional stress diffusion in a plate following earthquake faulting on a finite fault; (2) two dimensional finite-element solutions for the global state of stress at the Earth's surface for possible plate driving forces; and (3) finite-element solutions for three dimensional stress diffusion in a viscoelastic Earth following earthquake faulting.

  20. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...