Sample records for pneumatic capsule pipeline

  1. Capsule injection system for a hydraulic capsule pipelining system

    DOEpatents

    Liu, Henry

    1982-01-01

    An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

  2. Aerodynamics of electrically driven freight pipeline system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundgren, T.S.; Zhao, Y.

    2000-06-01

    This paper examines the aerodynamic characteristics of a freight pipeline system in which freight capsules are individually propelled by electrical motors. The fundamental difference between this system and the more extensively studied pneumatic capsule pipeline is the different role played by aerodynamic forces. In a driven system the propelled capsules are resisted by aerodynamic forces and, in reaction, pump air through the tube. In contrast, in a pneumatically propelled system external blowers pump air through the tubes, and this provides the thrust for the capsules. An incompressible transient analysis is developed to study the aerodynamics of multiple capsules in amore » cross-linked two-bore pipeline. An aerodynamic friction coefficient is used as a cost parameter to compare the effects of capsule blockage and headway and to assess the merits of adits and vents. The authors conclude that optimum efficiency for off-design operation is obtained with long platoons of capsules in vented or adit connected tubes.« less

  3. Freight pipelines: Current status and anticipated future use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-07-01

    This report is issued by the Task Committee on Freight Pipelines, Pipeline Division, ASCE. Freight pipelines of various types (including slurry pipeline, pneumatic pipeline, and capsule pipeline) have been used throughout the world for over a century for transporting solid and sometimes even package products. Recent advancements in pipeline technology, aided by advanced computer control systems and trenchless technologies, have greatly facilitated the transportation of solids by pipelines. Today, in many situations, freight pipelines are not only the most economical and practical means for transporting solids, they are also the most reliable, safest and most environmentally friendly transportation mode. Increasedmore » use of underground pipelines to transport freight is anticipated in the future, especially as the technology continues to improve and surface transportation modes such as highways become more congested. This paper describes the state of the art and expected future uses of various types of freight pipelines. Obstacles hindering the development and use of the most advanced freight pipeline systems, such as the pneumatic capsule pipeline for interstate transport of freight, are discussed.« less

  4. Ultrahigh speed en face OCT capsule for endoscopic imaging

    PubMed Central

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.

    2015-01-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001

  5. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    PubMed

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  6. Experimental Verification of Pneumatic Transport System for the Rapid Excavation of Tunnels: Part 1. Installation of Test Facility

    DOT National Transportation Integrated Search

    1978-03-01

    This report deals with the selection of a test site, the design of a test installation, equipment selection, the installation and start-up of a pneumatic pipeline system for the transportation of tunnel muck. A review of prior pneumatic applications ...

  7. Field demonstration of two pneumatic backfilling technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyni, R.C.; Burnett, M.; Philbin, D.

    1995-12-31

    This US Bureau of Mines (USBM) report summarizes a field demonstration of pneumatic backfilling technologies conducted at the abandoned Hillside Coal and Iron Slope in Vandling, PA. Researchers demonstrated two pneumatic backfilling technologies recently developed under the USBM`s Abandoned Mine Reclamation Research Program, the Pneumatic Pipefeeder and the High-Efficiency Ejector. Both systems had previously been evaluated at the USBM`s subsidence abatement investigation laboratory near Fairchance, PA. The objective of the demonstration was to fill 100% of the abandoned tunnel with backfill stone to prevent further subsidence. The pneumatic Pipefeeder was used for 21 days, at a rate of 63 tomore » 124 t/d (69 to 136 st/d), to fill 88% of the tunnel. The High-Efficiency Ejector was used for 2 days, at a rate of 125 to 132 T/d (138 to 146 st/d) to fill the remaining 12% of the tunnel. The backfill placed by both systems was tightly compacted. The major problem encountered was wear on the polyethylene pipeline from the abrasion of the high-velocity backfill. The use of heavier steel pipe minimized the problem. A cost analysis for the entire project is given.« less

  8. Experimental Verification of a Pneumatic Transport System for the Rapid Evacuation of Tunnels, Part II - Test Program

    DOT National Transportation Integrated Search

    1978-12-01

    This study is the final phase of a muck pipeline program begun in 1973. The objective of the study was to evaluate a pneumatic pipeline system for muck haulage from a tunnel excavated by a tunnel boring machine. The system was comprised of a muck pre...

  9. Development of the prototype pneumatic transfer system for ITER neutron activation system.

    PubMed

    Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  10. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  11. Numerical investigation of influence on heat transfer characteristics to pneumatically conveyed dense phase flow by selecting models and boundary conditions

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Liu, Q.; Li, Y.

    2012-03-01

    Solids moving with a gas stream in a pipeline can be found in many industrial processes, such as power generation, chemical, pharmaceutical, food and commodity transfer processes. A mass flow rate of the solids is important characteristic that is often required to be measured (and controlled) to achieve efficient utilization of energy and raw materials in pneumatic conveying systems. The methods of measuring the mass flow rate of solids in a pneumatic pipeline can be divided into direct and indirect (inferential) measurements. A thermal solids' mass flow-meter, in principle, should ideally provide a direct measurement of solids flow rate, regardless of inhomogeneities in solids' distribution and environmental impacts. One key issue in developing a thermal solids' mass flow-meter is to characterize the heat transfer between the hot pipe wall and the gas-solids dense phase flow. The Eulerian continuum modeling with gas-solid two phases is the most common method for pneumatic transport. To model a gas-solid dense phase flow passing through a heated region, the gas phase is described as a continuous phase and the particles as the second phase. This study aims to describe the heat transfer characteristics between the hot wall and the gas-solids dense phase flow in pneumatic pipelines by modeling a turbulence gas-solid plug passing through the heated region which involves several actual and crucial issues: selections of interphase exchange coefficient, near-wall region functions and different wall surface temperatures. A sensitivity analysis was discussed to identify the influence on the heat transfer characteristics by selecting different interphase exchange coefficient models and different boundary conditions. Simulation results suggest that sensitivity analysis in the choice of models is very significant. The simulation results appear to show that a combination of choosing the Syamlal-O'Brien interphase exchange coefficient model and the standard k-ɛ model along with

  12. Microfluidic Pneumatic Logic Circuits and Digital Pneumatic Microprocessors for Integrated Microfluidic Systems

    PubMed Central

    Rhee, Minsoung

    2010-01-01

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprecessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner. PMID:19823730

  13. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    PubMed

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  14. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  15. Craniocervical Pneumatization

    PubMed Central

    Quigley, Alan James; Shannon, Helen

    2013-01-01

    Craniocervical bony pneumatization is a rare finding, with limited numbers of cases reported in the literature. It is thought to be linked to Eustachian tube dysfunction and a ball valve mechanism, and has a link with recurrent Valsalva maneuvers. We report a case of pneumatization of the occiput, atlas (C1) and axis (C2) in a patient with extensive ENT (Ear, Nose and Throat) surgical history who presented following a fall. Plain film, CT and MRI images are presented. PMID:24421950

  16. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  17. Design Optimization of Innovative High-Level Waste Pipeline Unplugging Technologies - 13341

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pribanic, T.; Awwad, A.; Varona, J.

    2013-07-01

    Florida International University (FIU) is currently working on the development and optimization of two innovative pipeline unplugging methods: the asynchronous pulsing system (APS) and the peristaltic crawler system (PCS). Experiments were conducted on the APS to determine how air in the pipeline influences the system's performance as well as determine the effectiveness of air mitigation techniques in a pipeline. The results obtained during the experimental phase of the project, including data from pipeline pressure pulse tests along with air bubble compression tests are presented. Single-cycle pulse amplification caused by a fast-acting cylinder piston pump in 21.8, 30.5, and 43.6 mmore » pipelines were evaluated. Experiments were conducted on fully flooded pipelines as well as pipelines that contained various amounts of air to evaluate the system's performance when air is present in the pipeline. Also presented are details of the improvements implemented to the third generation crawler system (PCS). The improvements include the redesign of the rims of the unit to accommodate a camera system that provides visual feedback of the conditions inside the pipeline. Visual feedback allows the crawler to be used as a pipeline unplugging and inspection tool. Tests conducted previously demonstrated a significant reduction of the crawler speed with increasing length of tether. Current improvements include the positioning of a pneumatic valve manifold system that is located in close proximity to the crawler, rendering tether length independent of crawler speed. Additional improvements to increase the crawler's speed were also investigated and presented. Descriptions of the test beds, which were designed to emulate possible scenarios present on the Department of Energy (DOE) pipelines, are presented. Finally, conclusions and recommendations for the systems are provided. (authors)« less

  18. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...

  19. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...

  20. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  1. Sliding pressure control valve for pneumatic hammer drill

    DOEpatents

    Polsky, Yarom [Albuquerque, NM

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  2. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  3. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  4. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  5. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  6. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  7. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  8. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  9. A Study of Gas Economizing Pneumatic Cylinder

    NASA Astrophysics Data System (ADS)

    Li, T. C.; Wu, H. W.; Kuo, M. J.

    2006-10-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.

  10. Comparative coal transportation costs: an economic and engineering analysis of truck, belt, rail, barge and coal slurry and pneumatic pipelines. Volume 3. Coal slurry pipelines. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rieber, M.; Soo, S.L.

    1977-08-01

    A coal slurry pipeline system requires that the coal go through a number of processing stages before it is used by the power plant. Once mined, the coal is delivered to a preparation plant where it is pulverized to sizes between 18 and 325 mesh and then suspended in about an equal weight of water. This 50-50 slurry mixture has a consistency approximating toothpaste. It is pushed through the pipeline via electric pumping stations 70 to 100 miles apart. Flow velocity through the line must be maintained within a narrow range. For example, if a 3.5 mph design is usedmore » at 5 mph, the system must be able to withstand double the horsepower, peak pressure, and wear. Minimum flowrate must be maintained to avoid particle settling and plugging. However, in general, once a pipeline system has been designed, because of economic considerations on the one hand and design limits on the other, flowrate is rather inflexible. Pipelines that have a slowly moving throughput and a water carrier may be subject to freezing in northern areas during periods of severe cold. One of the problems associated with slurry pipeline analyses is the lack of operating experience.« less

  11. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  12. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  13. Inexpensive Dramatic Pneumatic Lift

    NASA Astrophysics Data System (ADS)

    Morse, Robert A.

    2017-09-01

    Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article describes the construction and use of an inexpensive hand-held pneumatic lift to demonstrate the same principle.

  14. Continued Development and Improvement of Pneumatic Heavy Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in themore » first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type

  15. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  16. Capsule endoscopy

    MedlinePlus

    Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...

  17. [Modern pneumatic weapons and injuries they cause].

    PubMed

    Kozachenko, I N

    2013-01-01

    The data on the history of development and further improvement of pneumatic weapons are presented with special reference to specific features of different types and varieties of these weapons, cartridges for them, and the sphere of their application. Investigations into peculiarities of damages caused by high-capacity pneumatic weapons to the objects of forensic medical expertise affected from different distances are reviewed. Results of forensic medical expertise and clinical studies on the structure of body injuries inflicted by gunshots from pneumatic weapons to the human body are discussed. The author emphasizes the necessity of developing up-to-date terminology and classification of gunshot injuries caused by shooting from pneumatic weapons.

  18. Influence of capsule shell composition on the performance indicators of hypromellose capsule in comparison to hard gelatin capsules.

    PubMed

    Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani

    2015-01-01

    The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.

  19. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  20. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  1. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  2. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  3. Pneumatics.

    ERIC Educational Resources Information Center

    Engelbrecht, Nancy; And Others

    This unit on pneumatics, for use in postsecondary programs, is organized in eight sections. Each section consists of information sheets with line drawings and multiple-choice questions for each topic in the sections. Answers are provided at the back of the book. The following topics are covered: (1) introduction--pressure, principles of gases,…

  4. Key issues in theoretical and functional pneumatic design

    NASA Astrophysics Data System (ADS)

    Xu, Z. G.; Yang, D. Y.; Liu, W. M.; Liu, T. T.

    2017-10-01

    This paper studies the energy release of the pneumatic engine in different thermodynamic processes, the isothermal process is the highest power output process, while adiabatic process is the lowest energy output process, and the energy release of the pneumatic engine is a multi-state thermodynamic process between them. Therefore heat exchanging should be increased between the pneumatic engine and the outer space, the gas expansion process in the cylinder should be as close as possible to the isothermal process. Heat exchange should be increased between the cylinder and the external spaces. Secondly, the fin structure is studied to increase the heat exchanging between the cylinder body and the outside space. The upper part has fin structures and the lower cylinder has no fin structure, this structure improved the working efficiency of pneumatic engine. Finally the cam and the hydraulic bottle of pneumatic engines are designed. Simulation and theoretical calculation are used to the analysis of the whole structure, which lay the foundation for the manufacturing and design of the pneumatic engines.

  5. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  6. Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Feldman, Jason; Svehla, Danielle

    2003-01-01

    Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric

  7. Variable camber wing based on pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Yin, Weilong; Liu, Libo; Chen, Yijin; Leng, Jinsong

    2009-07-01

    As a novel bionic actuator, pneumatic artificial muscle has high power to weight ratio. In this paper, a variable camber wing with the pneumatic artificial muscle is developed. Firstly, the experimental setup to measure the static output force of pneumatic artificial muscle is designed. The relationship between the static output force and the air pressure is investigated. Experimental result shows the static output force of pneumatic artificial muscle decreases nonlinearly with increasing contraction ratio. Secondly, the finite element model of the variable camber wing is developed. Numerical results show that the tip displacement of the trailing-edge increases linearly with increasing external load and limited with the maximum static output force of pneumatic artificial muscles. Finally, the variable camber wing model is manufactured to validate the variable camber concept. Experimental result shows that the wing camber increases with increasing air pressure and that it compare very well with the FEM result.

  8. [Morphine self-administration by rats using a pneumatic syringe].

    PubMed

    Akiyama, Y; Takayama, S

    1988-06-01

    An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.

  9. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule

    PubMed Central

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases. PMID:26600772

  10. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule.

    PubMed

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases.

  11. Design Improvements and Analysis of Innovative High-Level Waste Pipeline Unplugging Technologies - 12171

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pribanic, Tomas; Awwad, Amer; Crespo, Jairo

    2012-07-01

    Transferring high-level waste (HLW) between storage tanks or to treatment facilities is a common practice performed at the Department of Energy (DoE) sites. Changes in the chemical and/or physical properties of the HLW slurry during the transfer process may lead to the formation of blockages inside the pipelines resulting in schedule delays and increased costs. To improve DoE's capabilities in the event of a pipeline plugging incident, FIU has continued to develop two novel unplugging technologies: an asynchronous pulsing system and a peristaltic crawler. The asynchronous pulsing system uses a hydraulic pulse generator to create pressure disturbances at two oppositemore » inlet locations of the pipeline to dislodge blockages by attacking the plug from both sides remotely. The peristaltic crawler is a pneumatic/hydraulic operated crawler that propels itself by a sequence of pressurization/depressurization of cavities (inner tubes). The crawler includes a frontal attachment that has a hydraulically powered unplugging tool. In this paper, details of the asynchronous pulsing system's ability to unplug a pipeline on a small-scale test-bed and results from the experimental testing of the second generation peristaltic crawler are provided. The paper concludes with future improvements for the third generation crawler and a recommended path forward for the asynchronous pulsing testing. (authors)« less

  12. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Pneumatic de-icer boot system. 23.1416...

  13. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pneumatic de-icer boot system. 23.1416...

  14. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Pneumatic de-icer boot system. 23.1416...

  15. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...

  16. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...

  17. Rigidified pneumatic composites

    NASA Astrophysics Data System (ADS)

    van Dessel, Steven

    2000-10-01

    The overall objective of the research presented in this dissertation was to address global issues of adequate housing for all and the need for more sustainable human settlement. In order to address these, the emerging technology of rigidified pneumatic composites was investigated. Rigidified pneumatic composites (RPC) are defined as thin flexible membrane structures that are pneumatically deployed. After deployment, these structures harden due to chemical or physical change of the membrane. Because of this change, these structures do no longer require pneumatic pressure to maintain their shape. For the first time, a systematic listing of the various means available to develop polymeric materials useful in RPC technology is presented. With the aim to reduce the cost of RPC structures, a new material was proposed, developed, and evaluated. This material involved the formation of a semi-interpenetrating polymer network based on poly vinyl chloride and an acrylate based reactive plasticizer. The economical and environmental performances of RPC structures using this new material were assessed by means of a case study. In this study, the performance of RPC technology was compared with that of a typical wood light frame structure in the application of a small single-family house. The study indicated that the cost of ownership in present day value for the RPC structure was approximately 33% less than the cost of a comparable wood light frame structure. The study also indicated that significant environmental benefits exist with the use of RPC structures. It was found that the RPC structure used significantly less resources compared to the wood light frame structure. About 3.5 times less materials coming from non-renewable fossil resources, about 2.5 times less materials coming from trees, and about 19 times less materials coming from inorganic resources was used in the RPC structure relative to the wood light frame structure. The study concluded with pointing out various

  18. Treatments for pediatric achalasia: Heller myotomy or pneumatic dilatation?

    PubMed

    Jung, C; Michaud, L; Mougenot, J-F; Lamblin, M-D; Philippe-Chomette, P; Cargill, G; Bonnevalle, M; Boige, N; Bellaïche, M; Viala, J; Hugot, J-P; Gottrand, F; Cezard, J-P

    2010-03-01

    The treatment of achalasia consists of reducing distal esophageal obstruction by either Heller myotomy surgery or endoscopic pneumatic dilatation. The aim of the present study was to evaluate the short- and middle-term results of these procedures in children. For technical reasons, children under six years old (n=8) were treated by surgery only, whereas patients over six years old (n=14) were treated by either Heller myotomy or pneumatic dilatation. Of the children aged under six years, 75% were symptom-free at six months and 83% at 24 months of follow-up. Of the patients aged over six years, complete remission was achieved by Heller myotomy in 44.5% vs. 55.5% by pneumatic dilatation after six months, and in 40% vs. 65%, respectively, after 24 months. Both pneumatic dilatation and Heller myotomy showed significant rates of failure. These results suggest that pneumatic dilatation may be considered a primary treatment in children over six years old. Also, where necessary, Heller myotomy and pneumatic dilatation may be used as complementary treatments.

  19. Method of sections in analytical calculations of pneumatic tires

    NASA Astrophysics Data System (ADS)

    Tarasov, V. N.; Boyarkina, I. V.

    2018-01-01

    Analytical calculations in the pneumatic tire theory are more preferable in comparison with experimental methods. The method of section of a pneumatic tire shell allows to obtain equations of intensities of internal forces in carcass elements and bead rings. Analytical dependencies of intensity of distributed forces have been obtained in tire equator points, on side walls (poles) and pneumatic tire bead rings. Along with planes in the capacity of secant surfaces cylindrical surfaces are used for the first time together with secant planes. The tire capacity equation has been obtained using the method of section, by means of which a contact body is cut off from the tire carcass along the contact perimeter by the surface which is normal to the bearing surface. It has been established that the Laplace equation for the solution of tasks of this class of pneumatic tires contains two unknown values that requires the generation of additional equations. The developed computational schemes of pneumatic tire sections and new equations allow to accelerate the pneumatic tire structure improvement process during engineering.

  20. Development of pneumatic actuator with low-wave reflection characteristics

    NASA Astrophysics Data System (ADS)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  1. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. To the left are several pneumatic panels. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  2. The effect of pneumatic dilation in management of postfundoplication dysphagia.

    PubMed

    Sunjaya, D; Podboy, A; Blackmon, S H; Katzka, D; Halland, M

    2017-06-01

    Fundoplication surgery is a commonly performed procedure for gastro-esophageal reflux disease or hiatal hernia repair. Up to 10% of patients develop persistent postoperative dysphagia after surgery. Data on the effectiveness of pneumatic dilation for treatment are limited. The aim of this study was to evaluate clinical outcomes and identify clinical factors associated with successful response to pneumatic dilation among patients with persistent postfundoplication dysphagia (PPFD). We retrospectively evaluated patients who had undergone pneumatic dilation for PPFD between 1999 and 2016. Patients with dysphagia or achalasia prior to fundoplication were excluded. Demographic information, surgical history, severity of dysphagia, and clinical outcomes were collected. Data pertaining to esophagram, manometry, endoscopy, and pneumatic dilation were also collected. We identified 38 patients (82% female, 95% Caucasian, and median age 59 years) with PPFD who completed pneumatic dilation. The median postfundoplication dysphagia score was 2. Eleven patients had abnormal peristalsis on manometry. Seventeen patients reported response (seven complete) with an average decrease of 1 in their dysphagia score. Fifteen patients underwent reoperation due to PPFD. Hiatal hernia repair was the only factor that predicts a higher response rate to pneumatic dilation. Only one patient in our study developed complication (pneumoperitoneum) from pneumatic dilation. We found that pneumatic dilation to be a safe treatment option for PPFD with moderate efficacy. Patients who developed PPFD after a hiatal hernia repair may gain the greatest benefit after pneumatic dilation. We were not able to identify additional clinical, radiological, endoscopic, or manometric parameters that were predictive of response. © 2017 John Wiley & Sons Ltd.

  3. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 117; Retreaded pneumatic tires. 571... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope. This standard specifies performance, labeling, and certification requirements for retreaded pneumatic...

  4. First Approach of Pneumatic Anthropomorphic Hand

    DTIC Science & Technology

    2001-10-25

    1 o f 3 FIRST APPROACH OF PNEUMATIC ANTHROPOMORPHIC HAND Jiménez, Omar; Leija, Lorenzo; Muñoz, Roberto Centro de Investigación y de Estudios...weight and minimum consumption, minimum control and natural appearance. Keywords- Anthropomorphic, hand, Pneumatic system, Prosthesis 1 . INTRODUCTION...The projects have been guided through an specific line of development. The project MARCUS[ 1 ] includes easiness as the most important aspect what

  5. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  6. High-pressure portable pneumatic drive unit.

    PubMed

    Hete, B F; Savage, M; Batur, C; Smith, W A; Golding, L A; Nosé, Y

    1989-12-01

    The left ventricular assist device (LVAD) of the Cleveland Clinic Foundation (CCF) is a single-chamber assist pump, driven by a high-pressure pneumatic cylinder. A low-cost, portable driver that will allow cardiac care patients, with a high-pressure pneumatic ventricle assist, more freedom of movement has been developed. The compact and light-weight configuration can provide periods of 2 h of freedom from a fixed position driver and does not use exotic technology.

  7. Retained Capsule Endoscope.

    PubMed

    Aihole, Jayalaxmi S; Vishnumurthy, G S; Babu, M Narendra

    2016-11-15

    Capsule endoscopy was invented to visualize the entire small intestine in a non- invasive manner in adults. 1 y, 9 mo-old boy presented with generalized edema for last 3 months. His routine investigations, including the upper gastrointestinal endoscopy, colonoscopy, and contrast enhanced computed tomography scan (CECT) were normal. In view of clinical suspicion of protein losing enteropathy, we planned capsule endoscopy. The capsule was not passed even after 3 weeks. Laparoscopy revealed impacted capsule in a dilated intestinal loop proximal to an ileal stricuture. Capsule endoscopy should be used judiciously in children.

  8. Modular "plug-and-play" capsules for multi-capsule environment in the gastrointestinal tract.

    PubMed

    Phee, S J; Ting, E K; Lin, L; Huynh, V A; Kencana, A P; Wong, K J; Tan, S L

    2009-01-01

    The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.

  9. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic tests (replaces 137.5). 56.97-35 Section 56.97-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General Requirements. When a pneumatic test is performed, it...

  10. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...

  11. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...

  12. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...

  13. Pneumatic fracturing of low permeability media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  14. Analysis of fine coal pneumatic systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying sizemore » consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.« less

  15. Assessment of Pneumatic Controller Emission Measurements ...

    EPA Pesticide Factsheets

    Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co

  16. A new pneumatic suspension system with independent stiffness and ride height tuning capabilities

    NASA Astrophysics Data System (ADS)

    Yin, Zhihong; Khajepour, Amir; Cao, Dongpu; Ebrahimi, Babak; Guo, Konghui

    2012-12-01

    This paper introduces a new pneumatic spring for vehicle suspension systems, allowing independent tuning of stiffness and ride height according to different vehicle operating conditions and driver preferences. The proposed pneumatic spring comprises a double-acting pneumatic cylinder, two accumulators and a tuning subsystem. This paper presents a detailed description of the pneumatic spring and its working principle. The mathematical model is established based on principles of thermo and fluid dynamics. An experimental setup has been designed and fabricated for testing and evaluating the proposed pneumatic spring. The analytical and experimental results confirm the capability of the new pneumatic spring system for independent tuning of stiffness and ride height. The mathematical model is verified and the capabilities of the pneumatic spring are further proved. It is concluded that this new pneumatic spring provides a more flexible suspension design alternative for meeting various conflicting suspension requirements for ride comfort and performance.

  17. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4370 Pneumatic cranial...

  18. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4370 Pneumatic cranial...

  19. TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review

    NASA Astrophysics Data System (ADS)

    De Volder, Michaël; Reynaerts, Dominiek

    2010-04-01

    The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.

  20. Soft pneumatic grippers embedded with stretchable electroadhesion

    NASA Astrophysics Data System (ADS)

    Guo, J.; Elgeneidy, K.; Xiang, C.; Lohse, N.; Justham, L.; Rossiter, J.

    2018-05-01

    Current soft pneumatic grippers cannot robustly grasp flat materials and flexible objects on curved surfaces without distorting them. Current electroadhesive grippers, on the other hand, are difficult to actively deform to complex shapes to pick up free-form surfaces or objects. An easy-to-implement PneuEA gripper is proposed by the integration of an electroadhesive gripper and a two-fingered soft pneumatic gripper. The electroadhesive gripper was fabricated by segmenting a soft conductive silicon sheet into a two-part electrode design and embedding it in a soft dielectric elastomer. The two-fingered soft pneumatic gripper was manufactured using a standard soft lithography approach. This novel integration has combined the benefits of both the electroadhesive and soft pneumatic grippers. As a result, the proposed PneuEA gripper was not only able to pick-and-place flat and flexible materials such as a porous cloth but also delicate objects such as a light bulb. By combining two soft touch sensors with the electroadhesive, an intelligent and shape-adaptive PneuEA material handling system has been developed. This work is expected to widen the applications of both soft gripper and electroadhesion technologies.

  1. Hemolysis associated with pneumatic tube system transport for blood samples

    PubMed Central

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830

  2. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  3. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  4. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  5. A high resolution pneumatic stepping actuator for harsh reactor environments

    NASA Astrophysics Data System (ADS)

    Tippetts, Thomas B.; Evans, Paul S.; Riffle, George K.

    1993-01-01

    A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball et al. (1991).

  6. Posterior capsule opacification.

    PubMed

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  7. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  8. Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.

    PubMed

    Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A

    2008-07-01

    Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.

  9. Cranial base morphology and temporal bone pneumatization in Asian Homo erectus.

    PubMed

    Balzeau, Antoine; Grimaud-Hervé, Dominique

    2006-10-01

    The external morphological features of the temporal bone are used frequently to determine taxonomic affinities of fossils of the genus Homo. Temporal bone pneumatization has been widely studied in great apes and in early hominids. However, this feature is rarely examined in the later hominids, particularly in Asian Homo erectus. We provide a comparative morphological and quantitative analysis of Asian Homo erectus from the sites of Ngandong, Sambungmacan, and Zhoukoudian, and of Neandertals and anatomically modern Homo sapiens in order to discuss causes and modalities of temporal bone pneumatization during hominid evolution. The evolution of temporal bone pneumatization in the genus Homo is more complex than previously described. Indeed, the Zhoukoudian fossils have a unique pattern of temporal bone pneumatization, whereas Ngandong and Sambungmacan fossils, as well as the Neandertals, more closely resemble the modern human pattern. Moreover, these Chinese fossils are characterized by a wide midvault and a relatively narrow occipital bone. Our results support the point of view that cell development does not play an active role in determining cranial base morphology. Instead, pneumatization is related to available space and to temporal bone morphology, and its development is related to correlated morphology and the relative disposition of the bones and cerebral lobes. Because variation in pneumatization is extensive within the same species, the phyletic implications of pneumatization are limited in the taxa considered here.

  10. A method of transmissibility design for dual-chamber pneumatic vibration isolator

    NASA Astrophysics Data System (ADS)

    Lee, Jeung-Hoon; Kim, Kwang-Joon

    2009-06-01

    Dual-chamber pneumatic vibration isolators have a wide range of applications for vibration isolation of vibration-sensitive equipment. Recent advances in precision machine tools and instruments such as medical devices and those related to nano-technology require better isolation performance, which can be efficiently achieved by precise modeling- and design- of the isolation system. This paper discusses an efficient transmissibility design method of a pneumatic vibration isolator wherein a complex stiffness model of a dual-chamber pneumatic spring developed in our previous study is employed. Three design parameters, the volume ratio between the two pneumatic chambers, the geometry of the capillary tube connecting the two pneumatic chambers, and, finally, the stiffness of the diaphragm employed for prevention of air leakage, were found to be important factors in transmissibility design. Based on a design technique that maximizes damping of the dual-chamber pneumatic spring, trade-offs among the resonance frequency of transmissibility, peak transmissibility, and transmissibility in high frequency range were found, which were not ever stated in previous researches. Furthermore, this paper discusses the negative role of the diaphragm in transmissibility design. The design method proposed in this paper is illustrated through experimental measurements.

  11. Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring.

    PubMed

    Fu, Xian Peng; Bu, Tian Zhao; Xi, Feng Ben; Cheng, Ting Hai; Zhang, Chi; Wang, Zhong Lin

    2017-09-20

    Pneumatic monitoring sensors have great demands for power supply in cylinder systems. Here, we present an embedded sliding triboelectric nanogenerator (TENG) in air cylinder as active sensors for position and velocity monitoring. The embedded TENG is composed of a circular poly(tetrafluoroethylene) polymer and a triangular copper electrode. The working mechanism as triboelectric active sensors and electric output performance are systematically investigated. By integrating into the pneumatic system, the embedded triboelectric active sensors have been used for real-time air pressure/flow monitoring and energy storage. Air pressures are measured from 0.04 to 0.12 MPa at a step of 0.02 MPa with a sensitivity of 49.235 V/MPa, as well as airflow from 50 to 250 L/min at a step of 50 L/min with a sensitivity of 0.002 μA·min/L. This work has first demonstrated triboelectric active sensors for pneumatic monitoring and may promote the development of TENG in intelligent pneumatic system.

  12. Use of pneumatic lithotripsy for managing difficult CBD calculi.

    PubMed

    Farooq Qadri, Syed Javid; Khan, Muneer; Khan, Naveed

    2011-01-01

    About 7-12% of patients who harbor gallbladder calculi concomitant common bile duct (CBD) calculi are present. The treatment of gallbladder calculi has standardized in the form of laparoscopic cholecystectomy but management of CBD calculi is still evolving. Endoscopic removal of CBD calculi <2 cm in diameter is successful in 90-100% of cases but patients harboring stones >2 cm in diameter high failure rates can be seen. Traditionally, laparoscopically one can achieve success rate comparable to endoscopic surgery but large and impacted calculi may cause failures. If one uses pneumatic lithotripsy during laparoscopic management of CBD calculi one can achieve 100% stone clearance irrespective of size, degree of hardness and impaction. This study evaluates the feasibility of using pneumatic lithotripsy for CBD calculi. To our knowledge this is the 1st reported series of using pneumatic lithotripsy for CBD calculi. From June 2002 to June 2010 96 laparoscopic CBD explorations (LCBDE) were done for CBD calculi. Patients having choledocholithiasis with CBD diameter of >10 mm were taken for LCBDE while in patients with CBD diameter of <10 mm were referred for endoscopic clearance. Additionally ERCP failure cases were also subjected to LCBDE. Rigid nephroscope was used for LCBDE and usually calculi were removed by forceps only. In patients having large, hard &/or impacted calculi pneumatic lithotripsy were used for fragmentation. Out of the 96 patients in 12 (12.5%) cases pneumatic lithotripsy was used for stone fragmentation. Out of these 12 cases 5 (41.6%) were ERCP failure cases. At a mean hospital stay of 2.5 days 100% stone clearance was achieved in all cases with no perioperative complication. The present study shows how successfully pneumatic lithotripsy can be used to fragment large, hard &/or impacted CBD calculi. Pneumatic lithotripsy being user friendly easily available can reliably fragment CBD calculi in one session. Copyright © 2010 Surgical Associates

  13. Pediatric capsule endoscopy: review of the small bowel and patency capsules.

    PubMed

    Cohen, Stanley A; Ephrath, Hagit; Lewis, Jeffery D; Klevens, Alan; Bergwerk, Ari; Liu, Steven; Patel, Dinesh; Reed-Knight, Bonney; Stallworth, Angela; Wakhisi, Tamara; Gold, Benjamin D

    2012-03-01

    Because capsule endoscopy (CE) avoids ionizing radiation, deep sedation, and general anesthesia, CE may be valuable in pediatrics. We report a single pediatric center's experience with the use and safety of CE. In a retrospective review of consecutive CE studies, 284 CE studies were performed in 277 patients with a mean age of 15 (±3.7) years during a 5-year period. The youngest to swallow the capsule was 4.6 years old. Twenty capsules were placed. Overall, 245 (86%) patients underwent CE for suspected (184, 65%) or confirmed (61, 21%) Crohn disease (CD); 27 (9.5%) anemia or gastrointestinal bleeding; 6 (2%) polyposis; and 4 (1.4%) celiac disease. Positive findings were observed in 205 (72%) of the studies, with 152 (54%) having small bowel findings. Of these, 72 (47%) were diagnostic. Gastric (95, 33%) and colonic (31, 11%) abnormalities were also identified. Five CE studies (1.8%) resulted in retention of the capsule in nonsurgical patients. A patency capsule before CE in 23 patients allowed 19 CE to proceed with only 1 retained capsule. In 65 (21%) patients, the video capsule did not enter the colon before the video's end. Of these, 36 (65%) had significant findings, including 27 (49%) documenting small bowel (SB) CD. CE is useful to diagnose SB disease in children. Even in a study population with a high prevalence of confirmed and suspected CD, the risk of retention remains small. The patency capsule may lessen that risk. CE may identify gastric or colonic disease even when SB lesions are not present.

  14. Design and Dynamic Model of a Frog-inspired Swimming Robot Powered by Pneumatic Muscles

    NASA Astrophysics Data System (ADS)

    Fan, Ji-Zhuang; Zhang, Wei; Kong, Peng-Cheng; Cai, He-Gao; Liu, Gang-Feng

    2017-09-01

    Pneumatic muscles with similar characteristics to biological muscles have been widely used in robots, and thus are promising drivers for frog inspired robots. However, the application and nonlinearity of the pneumatic system limit the advance. On the basis of the swimming mechanism of the frog, a frog-inspired robot based on pneumatic muscles is developed. To realize the independent tasks by the robot, a pneumatic system with internal chambers, micro air pump, and valves is implemented. The micro pump is used to maintain the pressure difference between the source and exhaust chambers. The pneumatic muscles are controlled by high-speed switch valves which can reduce the robot cost, volume, and mass. A dynamic model of the pneumatic system is established for the simulation to estimate the system, including the chamber, muscle, and pneumatic circuit models. The robot design is verified by the robot swimming experiments and the dynamic model is verified through the experiments and simulations of the pneumatic system. The simulation results are compared to analyze the functions of the source pressure, internal volume of the muscle, and circuit flow rate which is proved the main factor that limits the response of muscle pressure. The proposed research provides the application of the pneumatic muscles in the frog inspired robot and the pneumatic model to study muscle controller.

  15. A Pneumatic Tactile Sensor for Co-Operative Robots

    PubMed Central

    He, Rui; Yu, Jianjun; Zuo, Guoyu

    2017-01-01

    Tactile sensors of comprehensive functions are urgently needed for the advanced robot to co-exist and co-operate with human beings. Pneumatic tactile sensors based on air bladder possess some noticeable advantages for human-robot interaction application. In this paper, we construct a pneumatic tactile sensor and apply it on the fingertip of robot hand to realize the sensing of force, vibration and slippage via the change of the pressure of the air bladder, and we utilize the sensor to perceive the object’s features such as softness and roughness. The pneumatic tactile sensor has good linearity, repeatability and low hysteresis and both its size and sensing range can be customized by using different material as well as different thicknesses of the air bladder. It is also simple and cheap to fabricate. Therefore, the pneumatic tactile sensor is suitable for the application of co-operative robots and can be widely utilized to improve the performance of service robots. We can apply it to the fingertip of the robot to endow the robotic hand with the ability to co-operate with humans and handle the fragile objects because of the inherent compliance of the air bladder. PMID:29125565

  16. Pneumatic wrench retains or discharges nuts or bolts as desired

    NASA Technical Reports Server (NTRS)

    Bouille, J. R.

    1966-01-01

    Pneumatic wrench grips, screws or unscrews, and discharges a nut or bolt as desired. The device consists of a standard pneumatic wrench modified with a special hex bolt head socket assembly and a diaphragm air cylinder.

  17. Integration of Pneumatic Technology in Powered Mobility Devices

    PubMed Central

    Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G.; Schneider, Urs

    2017-01-01

    Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs. PMID:29339888

  18. Integration of Pneumatic Technology in Powered Mobility Devices.

    PubMed

    Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G; Schneider, Urs; Cooper, Rory A

    2017-01-01

    Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs.

  19. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  20. Biocompatible Capsules and Methods of Making

    NASA Technical Reports Server (NTRS)

    Loftus, David J. (Inventor)

    2017-01-01

    Embodiments of the invention include capsules for containing medical implants and delivery systems for release of active biological substances into a host body. Delivery systems comprise a capsule comprising an interior enclosed by walls, and a source of active biological substances enclosed within the capsule interior, wherein the active biological substances are free to diffuse across the capsule walls. The capsule walls comprise a continuous mesh of biocompatible fibers and a seal region where two capsule walls overlap. The interior of the capsule is substantially isolated from the medium surrounding the capsule, except for diffusion of at least one species of molecule between the capsule interior and the ambient medium, and prevents cell migration into or out of the capsule. Methods for preparing and using the capsules and delivery systems are provided.

  1. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    PubMed

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  2. Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems

    DOEpatents

    Tice, Joshua D.; Bassett, Thomas A.; Desai, Amit V.; Apblett, Christopher A.; Kenis, Paul J. A.

    2016-09-20

    An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.

  3. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  4. 77 FR 70543 - Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    .... PHMSA-2009-0203] Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline..., and safety policies for natural gas pipelines and for hazardous liquid pipelines. Both committees were...: Notice of advisory committee meeting. SUMMARY: This notice announces a public meeting of the Gas Pipeline...

  5. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  6. Precharged Pneumatic Soft Actuators and Their Applications to Untethered Soft Robots.

    PubMed

    Li, Yunquan; Chen, Yonghua; Ren, Tao; Li, Yingtian; Choi, Shiu Hong

    2018-06-20

    The past decade has witnessed tremendous progress in soft robotics. Unlike most pneumatic-based methods, we present a new approach to soft robot design based on precharged pneumatics (PCP). We propose a PCP soft bending actuator, which is actuated by precharged air pressure and retracted by inextensible tendons. By pulling or releasing the tendons, the air pressure in the soft actuator is modulated, and hence, its bending angle. The tendons serve in a way similar to pressure-regulating valves that are used in typical pneumatic systems. The linear motion of tendons is transduced into complex motion via the prepressurized bent soft actuator. Furthermore, since a PCP actuator does not need any gas supply, complicated pneumatic control systems used in traditional soft robotics are eliminated. This facilitates the development of compact untethered autonomous soft robots for various applications. Both theoretical modeling and experimental validation have been conducted on a sample PCP soft actuator design. A fully untethered autonomous quadrupedal soft robot and a soft gripper have been developed to demonstrate the superiority of the proposed approach over traditional pneumatic-driven soft robots.

  7. Changes in biomechanical properties of glenohumeral joint capsules with adhesive capsulitis by repeated capsule-preserving hydraulic distensions with saline solution and corticosteroid.

    PubMed

    Koh, Eun S; Chung, Sun G; Kim, Tae Uk; Kim, Hee Chan

    2012-12-01

    To investigate whether capsule-preserving hydraulic distension with saline solution and corticosteroid for adhesive capsulitis induces biomechanical alterations in glenohumeral joint capsules along with clinical improvements. A case series. University outpatient clinic of physical medicine and rehabilitation. Eighteen patients with unilateral adhesive capsulitis. INTERVENTION AND MAIN OUTCOME MEASUREMENTS: Three hydraulic distensions with saline solution and corticosteroid were performed with 1-month intervals. To avoid rupturing capsules, all distensions were monitored by using real-time pressure-volume curves. Stiffness, maximal volume capacity, and pressure at the maximal volume capacity of the capsule were measured at each intervention. Clinical parameters, such as pain and range of motion, were recorded before, 3 days after, and 1 month after each distension. Stiffness decreased (47.6 ± 27.1 mm Hg/mL to 31.7 ± 18.4 mm Hg/mL to 24.2 ± 14.0 mm Hg/mL, mean SD) and maximal volume capacity increased (18.8 ± 7.3 mL to 20.5 ± 7.5 mL to 24.2 ± 7.0 mL, mean SD) significantly (P = .001 for both) at each repeated hydraulic distension. Pressure at the maximal volume capacity tended to decrease, but the decrements were not statistically significant (P = .662). The clinical parameters were significantly improved throughout and 1 month after the 3 repeat procedures (P < .05 for all). Capsule-preserving hydraulic distension changed the biomechanical properties of the glenohumeral joint capsule, lessening the stiffness and enlarging the volume capacity. These alterations were accompanied by improved range of motion and relief of pain. Repeated capsule-preserving hydraulic distension with saline solution and corticosteroid would be useful to treat adhesive capsulitis and to evaluate the treatment results. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  8. 78 FR 70623 - Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2009-0203] Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory Committee AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. [[Page...

  9. Throttle pneumatic impact mechanism equipped with afterburner idle-stroke chamber

    NASA Astrophysics Data System (ADS)

    Dedov, Alexey; Frantseva, Eleanor; Dmitriev, Mikhail

    2017-01-01

    Pneumatic impact mechanisms are widely used in construction, mining and other economic sectors of a country. Such mechanisms are a base for a wide range of machines of various types and dimensions from hand-held tools to mounted piling hammers with impact energy up to 10 000 J. This paper is aimed at creation of pneumatic impact mechanism with the improved characteristics, including operation, energy use, weight and size which is especially important in space-limited working conditions. The research methods include development of computer mathematical model that can solve equations system and test a prototype model at the experimental stand. As a result of conducted research the pneumatic impact mechanism with the improved characteristics was developed. An engineering method for calculating throttle pneumatic impact mechanisms with a preset value of impact energy from 1 to 20 000 was investigated. This method allows creating percussive machines of a wide range of application.

  10. Analytical Solution to the Pneumatic Transient Rod System at ACRR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fehr, Brandon Michael

    2016-01-08

    The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validatedmore » against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.« less

  11. Mercury Capsule Separation Tests

    NASA Image and Video Library

    1960-04-01

    Mercury capsule separation from Redstone booster in the Altitude Wind Tunnel (AWT): NASA Lewis conducted full-scale separation tests of the posigrade rockets that were fired after the Redstone rockets burned out. The researchers studied the effect of the posigrade rockets firing on the Redstone booster and retrograde package. This film shows the Mercury capsule being mounted to the Redstone missile model in the Altitude Wind Tunnel. The capsule's engines are fired and it horizontally separates from the Atlas. After firing the capsule swings from an overhead crane.

  12. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...

  13. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...

  14. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...

  15. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...

  16. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...

  17. Pneumatic Compression, But Not Exercise, Can Avoid Intradialytic Hypotension: A Randomized Trial.

    PubMed

    Álvares, Valeria R C; Ramos, Camila D; Pereira, Benedito J; Pinto, Ana Lucia; Moysés, Rosa M A; Gualano, Bruno; Elias, Rosilene M

    2017-01-01

    Conventional hemodialysis (HD) is associated with dialysis-induced hypotension (DIH) and ineffective phosphate removal. As the main source of extracellular fluid removed during HD are the legs, we sought to reduce DIH and increase phosphate removal by using cycling and pneumatic compression, which would potentially provide higher venous return, preserving central blood flow and also offering more phosphate to the dialyzer. We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60 min; and pneumatic compression during the first 60 min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and direct quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) ≥20 mm Hg. There was no difference in the ultrafiltration rate (p = 0.628), delta weight (p = 0.415), delta of total, intra and extracellular body water among the control, cycling, and pneumatic compression (p = 0.209, p = 0.348, and p = 0.467 respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling, and pneumatic compression respectively (-4.7 [-17.2, 8.2], -4.7 [-20.5, -0.2], and -2.3 [-8.1, 9.0] mm Hg; p = 0.021). DIH occurred in 43, 38, and 24% of patients in control, cycling, and pneumatic compression respectively (p = 0.014). Phosphate removal did not increase in any intervention (p = 0.486). Higher phosphate removal was dependent on ultrafiltration, pre dialysis serum phosphate, and higher parathyroid hormone. Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit there was no effect on fluid parameters. Neither exercise nor pneumatic compression increased phosphate removal. © 2017 S. Karger AG, Basel.

  18. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Delaplaine, R. W.; Greenleaf, J. E.

    1979-01-01

    Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

  19. Engineering fluorescent poly(dopamine) capsules.

    PubMed

    Chen, Xi; Yan, Yan; Müllner, Markus; van Koeverden, Martin P; Noi, Ka Fung; Zhu, Wei; Caruso, Frank

    2014-03-18

    The recent development of poly(dopamine) (PDA) capsules provides new opportunities for their application in biology and medicine. To advance the biomedical application of PDA capsules, strategies that enable the preparation of fluorescently labeled PDA (F-PDA) capsules are required, as this will allow evaluation of their cellular interactions using a range of fluorescence-based techniques. Herein, we report a facile approach for the fabrication of F-PDA capsules via the polymerization of dopamine (DA) on sacrificial templates in the presence of hydrogen peroxide (H2O2). F-PDA capsules with well-defined sizes are prepared by templating different organic and inorganic particles. The resulting F-PDA capsules show negligible cytotoxicity in HeLa cells after incubation for 48 h. We also demonstrate visualization of the F-PDA capsules following internalization by HeLa cells using conventional fluorescence microscopy, en route toward detailed investigations on their biological interactions.

  20. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...

  1. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...

  2. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...

  3. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...

  4. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...

  5. Development of Pneumatic Robot Hand and Construction of Master-Slave System

    NASA Astrophysics Data System (ADS)

    Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori

    Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.

  6. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the top level of the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  7. The Lens Capsule

    PubMed Central

    Danysh, Brian P.; Duncan, Melinda K.

    2009-01-01

    The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892

  8. Magneto-responsive alginate capsules.

    PubMed

    Degen, Patrick; Zwar, Elena; Schulz, Imke; Rehage, Heinz

    2015-05-20

    Upon incorporation of magnetic nanoparticles (mNPs) into gels, composite materials called ferrogels are obtained. These magneto-responsive systems have a wide range of potential applications including switches and sensors as well as drug delivery systems. In this article, we focus on the properties of calcium alginate capsules, which are widely used as carrier systems in medicine and technology. We studied the incorporation of different kinds of mNPs in matrix capsules and in the core and the shell of hollow particles. We found out that not all particle-alginate or particle-CaCl2 solution combinations were suitable for a successful capsule preparation on grounds of a destabilization of the nanoparticles or the polymer. For those systems allowing the preparation of switchable beads or capsules, we systematically studied the size and microscopic structure of the capsules, their magnetic behavior and mechanical resistance.

  9. Oxygen Fugacity in Large Metal Capsules

    NASA Astrophysics Data System (ADS)

    Faul, U.; Cline, C. J., II; Jackson, I.; Berry, A.

    2016-12-01

    During experiments with iron bearing silicates, equilibration between metal capsules and sample interior depends on diffusion of Fe if the capsule composition is not initially in equilibrium with the sample composition. For example, placing Pt or Ni capsules in contact with Fe-bearing olivine leads to Fe-loss from the olivine. In a fully equilibrated system the Fe contents of coexisting metal capsule and olivine reflect the oxygen fugacity (fO2) of the system. Experiments were conducted with olivine encapsulated or wrapped in four different metals (Fe, Ni70Fe30, Ni and Pt) to determine the fO2 in the cm-sized samples used for deformation and seismic property experiments. Small Pt particles mixed with olivine powder were used as fO2 sensors in the interior of the capsules. The results show an ordering of the fO2 in the interior that is consistent with the enclosing metals, i.e. the fO2 is lowest in a Fe capsule and highest in a Pt capsule. However, fO2 values in the more oxidizing metal capsules are substantially below their respective metal-oxide buffers. For example, solgel olivine encapsulated in Ni has an oxygen fugacity that is more than three orders of magnitude below Ni-NiO at 1200C and 0.3 GPa. The fO2 in a capsule interior is therefore to some extent self-buffering and only moderately influenced by the composition of the capsule. While the Pt particles in the interior are equilibrated, Fe gradients from the interior up to the Pt and Ni sample-capsule interfaces show that Fe loss into the capsules is diffusion limited. The fO2 at the interface also has implications for the water retention in unbuffered capsules. We infer that relatively high fO2 and hence fH2O observed adjacent to Pt capsules enables retention of water in these capsules, but the fO2 adjacent to Ni capsules is too low and water is lost.

  10. Does the Degree of the Mastoid Pneumatization Affect the Side of Bell Palsy?

    PubMed

    Güneş, Selçuk; Çelik, Mustafa; Çolak, Ceylan; Olgun, Burak

    2018-02-26

    The aim is to investigate the impact of degree of mastoid pneumatization on the affected side of Bell palsy (BP). Retrospective study in tertiary academic hospital. In total, 52 patients who were diagnosed with as BP were included in the study. Each patient was staged using House-Brackmann (HB) staging system. All patients underwent temporal bone computed tomography imaging. House-Brackmann scores, side of the BP, and mastoid pneumatization of all of patients were evaluated in the present study. Regarding the degree of the mastoid pneumatization, there were no significant differences between the affected side and the unaffected side (P = 0.439). The degree of the mastoid pneumatization of the affected side and the unaffected side did not differ between males and females (P = 0.918 for the affected side, P = 0.765 for the unaffected side, respectively). A negative correlation between the age and mastoid pneumatization of each side was found (P = 0.001, P = 0.025, respectively). There was no significant correlation between HB score and the degree of the mastoid pneumatization of each side (P = 0.789, P = 0.703). As a conclusion, the degree of the mastoid pneumatization is not one of the risk factors for BP. Further randomized studies with larger numbers of patients are needed to confirm these findings.

  11. Inexpensive Dramatic Pneumatic Lift

    ERIC Educational Resources Information Center

    Morse, Robert A.

    2017-01-01

    Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article…

  12. High-Torque, Lightweight, Pneumatically Driven Wrench For Small Spaces

    NASA Technical Reports Server (NTRS)

    Miller, Thomas W.

    1995-01-01

    Pneumatically driven wrench provides torque up to 3,000 lb. per ft. in small space. Designed to reach into 2.6 x 2.75 x 6 in. pocket. Weighs approximately 25 lbs. Includes reversible pneumatic motor (electric motor could be used instead) and slip clutch. Also includes device indicating total angle through which wrench turned bolt or nut. This feature used for turn-of-the-nut tightening method.

  13. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure.

    PubMed

    Won, Jungeun; Monroy, Guillermo L; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C; Novak, Michael A; Porter, Ryan G; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A

    2018-02-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch's t- test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM.

  14. Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.

    PubMed

    Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung

    2009-08-01

    The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.

  15. Polydopamine-coated capsules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  16. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  17. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    NASA Technical Reports Server (NTRS)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  18. Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.

    PubMed

    Canby-Hagino, E D; Caballero, R D; Harmon, W J

    1999-12-01

    Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.

  19. Pneumatic Regolith Transfer Systems for In Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack

    2010-01-01

    This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.

  20. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure

    PubMed Central

    Won, Jungeun; Monroy, Guillermo L.; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C.; Novak, Michael A.; Porter, Ryan G.; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A.

    2018-01-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch’s t-test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM. PMID:29552381

  1. 76 FR 70953 - Pipeline Safety: Safety of Gas Transmission Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 [Docket ID PHMSA-2011-0023] RIN 2137-AE72 Pipeline Safety: Safety of Gas Transmission Pipelines AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Advance notice of...

  2. Ethical aspects of capsule endoscopy.

    PubMed

    Niv, Yaron

    2008-01-01

    Capsule endoscopy is the most recent innovation in gastrointestinal endoscopy. The capsule contains a video camera that photographs the bowel for 8 h after the capsule has been orally ingested and transmits the images for interpretation to a computerized workstation. Ethical considerations of the use of capsule endoscopy should cover the following main issues: justification of the procedure, its potential benefits and harm, and patient autonomy. Capsule endoscopy has several advantages over traditional endoscopy. The procedure is painless, does not require sedation, is easy to perform and for the first time enables exploration of the entire small bowel at high magnification. However, the clinician cannot control its passive advance along the bowel. In addition, the examination may be incomplete, as the capsule reaches the cecum in only 80% of cases. This paper discusses the problems related to the new endoscopic procedure, the diagnostic yield in comparison with other procedures, proper indications for the procedure, outcome and complications. Copyright 2008 S. Karger AG, Basel.

  3. Polyelectrolyte capsules preloaded with interconnected alginate matrix: An effective capsule system for encapsulation and release of macromolecules.

    PubMed

    Sundaramurthy, Anandhakumar; Sundramoorthy, Ashok K

    2018-02-01

    In recent years, the design of stimuli-responsive hollow polymeric capsules is of tremendous interest for the scientific community because of the broad application of these capsules in the biomedical field. The use of weak polyelectrolytes as layer components for capsule fabrication is especially interesting as it results in hollow capsules that show unique release characteristics under physiological conditions. In this work, a methodology to prepare sub-micron sized alginate doped calcium carbonate (CaCO 3 ) particles through controlled precipitation in the presence of alginate is reported. Hollow capsules obtained by Layer-by-Layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) are showing an interconnected alginate matrix in the interior of the capsules. Investigations showed that the presence of alginate matrix enhances the encapsulation of cationic molecules (e.g. doxorubicin hydrochloride) manifold by charge controlled attraction mechanism. Capsule permeability investigated by confocal laser scanning microscopy revealed that the transformation from an open state to closed state is accompanied by an intermediate state where capsules are neither open nor closed. Furthermore, time dependent study indicated that the encapsulation process is linear as a function of time. The cell viability experiments demonstrated excellent biocompatibility of hollow capsules with mouse embryonic fibroblast cells. Anticancer investigations showed that DOX loaded capsules have significant anti-proliferative characteristics against HeLa cells. Such capsules have high potential for use as drug carrier for cationic drugs in cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles

    PubMed Central

    Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake

    2005-01-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019

  5. Liquid-metal dip seal with pneumatic spring

    DOEpatents

    Poindexter, Allan M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.

  6. Influence of Isoinertial-Pneumatic Mixed Resistances on Force-Velocity Relationship.

    PubMed

    Avrillon, Simon; Jidovtseff, Boris; Hug, François; Guilhem, Gaël

    2017-03-01

    Muscle strengthening is commonly based on the use of isoinertial loading, whereas variable resistances such as pneumatic loading may be implemented to optimize training stimulus. The purpose of the current study was to determine the effect of the ratio between pneumatic and isoinertial resistance on the force-velocity relationship during ballistic movements. A total of 15 participants performed 2 concentric repetitions of ballistic bench-press movements with intention to throw the bar at 30%, 45%, 60%, 75%, and 90% of the maximal concentric repetition with 5 resistance ratios including 100%, 75%, 50%, 25%, or 0% of pneumatic resistance, the additional load being isoinertial. Force-, velocity-, and power-time patterns were assessed and averaged over the concentric phase to determine the force-velocity and power-velocity relationships for each resistance ratio. Each 25% increase in the pneumatic part in the resistance ratio elicited higher movement velocity (+0.11 ± 0.03 m/s from 0% to 80% of the concentric phase) associated with lower force levels (-43.6 ± 15.2 N). Increased isoinertial part in the resistance ratio resulted in higher velocity toward the end of the movement (+0.23 ± 0.01 m/s from 90% to 100%). The findings show that the resistance ratio could be modulated to develop the acceleration phase and force toward the end of the concentric phase (pneumatic-oriented resistance). Inversely, isoinertial-oriented resistance should be used to develop maximal force and maximal power. Resistance modality could, therefore, be considered an innovative variable to modulate the training stimulus according to athletic purposes.

  7. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  8. Antibody immobilization using pneumatic spray: comparison with the avidin-biotin bridge immobilization method.

    PubMed

    Figueroa, Jhon; Magaña, Sonia; Lim, Daniel V; Schlaf, Rudy

    2012-12-14

    The formation of a thin antibody film on a glass surface using pneumatic spray was investigated as a potential immobilization technique for capturing pathogenic targets. Goat-Escherichia coli O157:H7 IgG films were made by pneumatic spray and compared against the avidin-biotin bridge immobilized films by assaying with green fluorescent protein (GFP) transformed E. coli O157:H7 cells and fluorescent reporter antibodies. Functionality, stability, and immobilization of the films were tested. The pneumatic spray films had lower fluorescence intensity values than the avidin-biotin bridge films but resulted in similar detection for E. coli O157:H7 at 10(5)-10(7)cells/ml sample concentrations with no detection of non-E. coli O157:H7 strains. Both methods also resulted in similar percent capture efficiencies. The results demonstrated that immobilization of antibody via pneumatic spray did not render the antibody non-functional and produced stable antibody films. The amount of time necessary for immobilization of the antibody was reduced significantly from 24h for the avidin-biotin bridge to 7 min using the pneumatic spray technique, with additional benefits of greatly reduced use of materials and chemicals. The pneumatic spray technique promises to be an alternative for the immobilization of antibodies on glass slides for capturing pathogenic targets and use in biosensor type devices. Copyright © 2012. Published by Elsevier B.V.

  9. Patency© and agile© capsules

    PubMed Central

    Caunedo-Álvarez, Ángel; Romero-Vazquez, Javier; Herrerias-Gutierrez, Juan M

    2008-01-01

    Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency© capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency© capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile© capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture. PMID:18785278

  10. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    NASA Astrophysics Data System (ADS)

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  11. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide.

    PubMed

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  12. Rolling resistance forces in pneumatic tires

    DOT National Transportation Integrated Search

    1976-01-31

    An analysis is presented for the influence of test drum curvature on stress levels and resulting rolling resistance forces in pneumatic tires. The influence of test method on the measurement of rolling loss is also considered, and expressions are der...

  13. 76 FR 73570 - Pipeline Safety: Miscellaneous Changes to Pipeline Safety Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-29

    ... pipeline facilities to facilitate the removal of liquids and other materials from the gas stream. These... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Parts... Changes to Pipeline Safety Regulations AGENCY: Pipeline and Hazardous Materials Safety Administration...

  14. Implementing AORN recommended practices for care of patients undergoing pneumatic tourniquet-assisted procedures.

    PubMed

    Hicks, Rodney W; Denholm, Bonnie

    2013-10-01

    Perioperative nurses are likely to encounter the use of pneumatic tourniquets in a variety of operative and invasive extremity procedures. Use of a pneumatic tourniquet offers an opportunity to obtain a near-bloodless surgical field; however, the use of tourniquets is not without risk. Unfavorable outcomes include pain, thrombotic events, nerve compression injuries, and disruption of skin integrity. Perioperative nurses should be familiar with the indications, contraindications, and changes in physiology associated with pneumatic tourniquet use. The revised AORN "Recommended practices for care of patients undergoing pneumatic tourniquet-assisted procedures" is focused on the perioperative nurse's role in patient care and provides guidance for developing, implementing, and evaluating practices that promote patient safety and improve the likelihood of positive outcomes. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  15. Magnetically guided capsule endoscopy.

    PubMed

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  16. Frictional properties of lubrication greases with the addition of nickel nanoparticles in pneumatic cylinder

    NASA Astrophysics Data System (ADS)

    Chang, Ho; Lan, Chou-Wei; Guo, Jia-Bin

    2011-12-01

    This paper studies the influence of addition of 100 nm diameter nickel nano-particles on the friction properties of synthetic grease (Li base, VG100) in pneumatic cylinder. The friction force test of pneumatic cylinder equipment measures the frictional force between seal and cylinder bore in pneumatic cylinders. The lubricants with addition of nickel nano-particles were used for lubricating the contact interface between seal and cylinder bore. The friction force test equipment employ a load cell force sensor to measure the friction force between seals and cylinder bores. Results obtained from experimental tests are compared to determine the friction force between seals and cylinder bore in pneumatic cylinders. The study leads to the conclusion that the addition of nickel nano-particles to synthetic grease results in a decrease in friction force between seals and cylinder bores in pneumatic cylinder. This tribological behavior is closely related to the deposition of nano-particles on the rubbing surfaces

  17. Research on precise pneumatic-electric displacement sensor with large measurement range

    NASA Astrophysics Data System (ADS)

    Yin, Zhehao; Yuan, Yibao; Liu, Baoshuai

    2017-10-01

    This research mainly focuses on precise pneumatic-electric displacement sensor which has large measurement range. Under the high precision, measurement range can be expanded so that the need of high precision as well as large range can be satisfied in the field of machining inspection technology. This research was started by the analysis of pneumatic-measuring theory. Then, an gas circuit measuring system which is based on differential pressure was designed. This designed system can reach two aims: Firstly, to convert displacement signal into gas signal; Secondly, to reduce the measurement error which caused by pressure and environmental turbulence. Furthermore, in consideration of the high requirement for linearity, sensitivity and stability, the project studied the pneumatic-electric transducer which puts the SCX series pressure sensor as a key part. The main purpose of this pneumatic-electric transducer is to convert gas signal to suitable electrical signal. Lastly, a broken line subsection linearization circuit was designed, which can nonlinear correct the output characteristic curve so as to enlarge the linear measurement range. The final result could be briefly described like this: under the condition that measuring error is less than 1μm, measurement range could be extended to approximately 200μm which is much higher than the measurement range of traditional pneumatic measuring instrument. Meanwhile, it can reach higher exchangeability and stability in order to become more suitable to engineering application.

  18. PipelineDog: a simple and flexible graphic pipeline construction and maintenance tool.

    PubMed

    Zhou, Anbo; Zhang, Yeting; Sun, Yazhou; Xing, Jinchuan

    2018-05-01

    Analysis pipelines are an essential part of bioinformatics research, and ad hoc pipelines are frequently created by researchers for prototyping and proof-of-concept purposes. However, most existing pipeline management system or workflow engines are too complex for rapid prototyping or learning the pipeline concept. A lightweight, user-friendly and flexible solution is thus desirable. In this study, we developed a new pipeline construction and maintenance tool, PipelineDog. This is a web-based integrated development environment with a modern web graphical user interface. It offers cross-platform compatibility, project management capabilities, code formatting and error checking functions and an online repository. It uses an easy-to-read/write script system that encourages code reuse. With the online repository, it also encourages sharing of pipelines, which enhances analysis reproducibility and accountability. For most users, PipelineDog requires no software installation. Overall, this web application provides a way to rapidly create and easily manage pipelines. PipelineDog web app is freely available at http://web.pipeline.dog. The command line version is available at http://www.npmjs.com/package/pipelinedog and online repository at http://repo.pipeline.dog. ysun@kean.edu or xing@biology.rutgers.edu or ysun@diagnoa.com. Supplementary data are available at Bioinformatics online.

  19. Powered glove with electro-pneumatic actuation unit for the disabled

    NASA Astrophysics Data System (ADS)

    Kawakami, Kosuke; Kumano, Shinichi; Moromugi, Shunji; Ishimatsu, Takakazu

    2007-12-01

    Authors have been developing a powered glove for people suffering from paralysis on their fingers to support their daily activity. Small air cylinders are used as actuators for this glove. Pneumatically-driven system has high advantages in case soft actuation is preferable. However, there are some problems to be solved in the pneumatically-driven system if the system is supposed to be used in our daily life. Huge air compressor is needed and solenoid valves emit loud sound for example. These problems are hurdles to commercialize the powered glove. To solve these problems authors have developed a new actuation unit by integrating an electric cylinder and an air cylinder. This actuation unit has advantages of both the electric actuation and the pneumatic actuation. Its advanced grip control ability has demonstrated through several experiments. The experimental results are reported in this paper.

  20. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  1. United States petroleum pipelines: An empirical analysis of pipeline sizing

    NASA Astrophysics Data System (ADS)

    Coburn, L. L.

    1980-12-01

    The undersizing theory hypothesizes that integrated oil companies have a strong economic incentive to size the petroleum pipelines they own and ship over in a way that means that some of the demand must utilize higher cost alternatives. The DOJ theory posits that excess or monopoly profits are earned due to the natural monopoly characteristics of petroleum pipelines and the existence of market power in some pipelines at either the upstream or downstream market. The theory holds that independent petroleum pipelines owned by companies not otherwise affiliated with the petroleum industry (independent pipelines) do not have these incentives and all the efficiencies of pipeline transportation are passed to the ultimate consumer. Integrated oil companies on the other hand, keep these cost efficiencies for themselves in the form of excess profits.

  2. Evaluation of a pneumatic Martian soil sampler concept

    NASA Technical Reports Server (NTRS)

    Schaefer, John L.; Neathery, James K.; Stencel, John M.

    1994-01-01

    The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

  3. Stennis time capsule

    NASA Image and Video Library

    2011-10-15

    Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary.

  4. Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles

    NASA Astrophysics Data System (ADS)

    Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel

    2018-03-01

    The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles

  5. Enema reduction of intussusception: the success rate of hydrostatic and pneumatic reduction.

    PubMed

    Khorana, Jiraporn; Singhavejsakul, Jesda; Ukarapol, Nuthapong; Laohapensang, Mongkol; Wakhanrittee, Junsujee; Patumanond, Jayanton

    2015-01-01

    Intussusception is a common surgical emergency in infants and children. The incidence of intussusception is from one to four per 2,000 infants and children. If there is no peritonitis, perforation sign on abdominal radiographic studies, and nonresponsive shock, nonoperative reduction by pneumatic or hydrostatic enema can be performed. The purpose of this study was to compare the success rates of both the methods. Two institutional retrospective cohort studies were performed. All intussusception patients (ICD-10 code K56.1) who had visited Chiang Mai University Hospital and Siriraj Hospital from January 2006 to December 2012 were included in the study. The data were obtained by chart reviews and electronic databases, which included demographic data, symptoms, signs, and investigations. The patients were grouped according to the method of reduction followed into pneumatic reduction and hydrostatic reduction groups with the outcome being the success of the reduction technique. One hundred and seventy episodes of intussusception occurring in the patients of Chiang Mai University Hospital and Siriraj Hospital were included in this study. The success rate of pneumatic reduction was 61% and that of hydrostatic reduction was 44% (P=0.036). Multivariable analysis and adjusting of the factors by propensity scores were performed; the success rate of pneumatic reduction was 1.48 times more than that of hydrostatic reduction (P=0.036, 95% confidence interval [CI] =1.03-2.13). Both pneumatic and hydrostatic reduction can be performed safely according to the experience of the radiologist or pediatric surgeon and hospital setting. This study showed that pneumatic reduction had a higher success rate than hydrostatic reduction.

  6. 75 FR 13342 - Pipeline Safety: Workshop on Distribution Pipeline Construction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-19

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID... natural gas distribution construction. Natural gas distribution pipelines are subject to a unique subset... distribution pipeline construction practices. This workshop will focus solely on natural gas distribution...

  7. The qualitative assessment of pneumatic actuators operation in terms of vibration criteria

    NASA Astrophysics Data System (ADS)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.

  8. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy.

    PubMed

    Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N

    2008-05-01

    Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.

  9. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  10. 75 FR 63774 - Pipeline Safety: Safety of On-Shore Hazardous Liquid Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-18

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... Pipelines AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), Department of... Gas Pipeline Safety Act of 1968, Public Law 90-481, delegated to DOT the authority to develop...

  11. 77 FR 61825 - Pipeline Safety: Notice of Public Meeting on Pipeline Data

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-11

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID... program performance measures for gas distribution, gas transmission, and hazardous liquids pipelines. The... distribution pipelines (49 CFR 192.1007(e)), gas transmission pipelines (49 CFR 192.945) and hazardous liquids...

  12. 76 FR 303 - Pipeline Safety: Safety of On-Shore Hazardous Liquid Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-04

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part 195 [Docket ID PHMSA-2010-0229] RIN 2137-AE66 Pipeline Safety: Safety of On-Shore Hazardous Liquid Pipelines AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice of...

  13. A randomized trial of pneumatic reduction versus hydrostatic reduction for intussusception in pediatric patients.

    PubMed

    Xie, Xiaolong; Wu, Yang; Wang, Qi; Zhao, Yiyang; Chen, Guobin; Xiang, Bo

    2017-08-08

    Data of randomly controlled trials comparing the hydrostatic and pneumatic reduction for intussusception in pediatric patients as initial therapy are lacking. The aim of this study was to conduct a randomly controlled trial to compare the effectiveness and safety of the hydrostatic and pneumatic reduction techniques. All intussusception patients who visited West China Hospital of Sichuan University from January 2014 to December 2015 were enrolled in this study in which they underwent pneumatic reduction or hydrostatic reduction. Patients were randomized into ultrasound-guided hydrostatic or X-ray-guided pneumatic reduction group. The data collected includes demographic data, symptoms, signs, and investigations. The primary outcome of the study was the success rate of reduction. And the secondary outcomes of the study were the rates of intestinal perforations and recurrence. A total of 124 children with intussusception who had met the inclusion criteria were enrolled. The overall success rate of this study was 90.32%. Univariable analysis showed that the success rate of hydrostatic reduction with normal saline (96.77%) was significantly higher than that of pneumatic reduction with air (83.87%) (p=0.015). Perforation after reduction was found in only one of the pneumatic reduction group. The recurrence rate of intussusception in the hydrostatic reduction group was 4.84% compared with 3.23% of pneumatic reduction group. Our study found that ultrasound-guided hydrostatic reduction is a simple, safe and effective nonoperative treatment for pediatric patients suffering from intussusceptions, and should be firstly adopted in the treatment of qualified patients. Therapeutic study TYPE OF STUDY: Prospective study. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Development and Applications of Pipeline Steel in Long-Distance Gas Pipeline of China

    NASA Astrophysics Data System (ADS)

    Chunyong, Huo; Yang, Li; Lingkang, Ji

    In past decades, with widely utilizing of Microalloying and Thermal Mechanical Control Processing (TMCP) technology, the good matching of strength, toughness, plasticity and weldability on pipeline steel has been reached so that oil and gas pipeline has been greatly developed in China to meet the demand of strong domestic consumption of energy. In this paper, development history of pipeline steel and gas pipeline in china is briefly reviewed. The microstructure characteristic and mechanical performance of pipeline steel used in some representative gas pipelines of china built in different stage are summarized. Through the analysis on the evolution of pipeline service environment, some prospective development trend of application of pipeline steel in China is also presented.

  15. Dielectric elastomer actuators used for pneumatic valve technology

    NASA Astrophysics Data System (ADS)

    Giousouf, Metin; Kovacs, Gabor

    2013-10-01

    Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications.

  16. Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.

    1990-01-01

    Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

  17. Gathering pipeline methane emissions in Fayetteville shale pipelines and scoping guidelines for future pipeline measurement campaigns

    DOE PAGES

    Zimmerle, Daniel J.; Pickering, Cody K.; Bell, Clay S.; ...

    2017-11-24

    Gathering pipelines, which transport gas from well pads to downstream processing, are a sector of the natural gas supply chain for which little measured methane emissions data are available. This study performed leak detection and measurement on 96 km of gathering pipeline and the associated 56 pigging facilities and 39 block valves. The study found one underground leak accounting for 83% (4.0 kg CH 4/hr) of total measured emissions. Methane emissions for the 4684 km of gathering pipeline in the study area were estimated at 402 kg CH 4/hr [95 to 1065 kg CH 4/hr, 95% CI], or 1% [0.2%more » to 2.6%] of all methane emissions measured during a prior aircraft study of the same area. Emissions estimated by this study fall within the uncertainty range of emissions estimated using emission factors from EPA's 2015 Greenhouse Inventory and study activity estimates. While EPA's current inventory is based upon emission factors from distribution mains measured in the 1990s, this study indicates that using emission factors from more recent distribution studies could significantly underestimate emissions from gathering pipelines. To guide broader studies of pipeline emissions, we also estimate the fraction of the pipeline length within a basin that must be measured to constrain uncertainty of pipeline emissions estimates to within 1% of total basin emissions. The study provides both substantial insight into the mix of emission sources and guidance for future gathering pipeline studies, but since measurements were made in a single basin, the results are not sufficiently representative to provide methane emission factors at the regional or national level.« less

  18. Gathering pipeline methane emissions in Fayetteville shale pipelines and scoping guidelines for future pipeline measurement campaigns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimmerle, Daniel J.; Pickering, Cody K.; Bell, Clay S.

    Gathering pipelines, which transport gas from well pads to downstream processing, are a sector of the natural gas supply chain for which little measured methane emissions data are available. This study performed leak detection and measurement on 96 km of gathering pipeline and the associated 56 pigging facilities and 39 block valves. The study found one underground leak accounting for 83% (4.0 kg CH 4/hr) of total measured emissions. Methane emissions for the 4684 km of gathering pipeline in the study area were estimated at 402 kg CH 4/hr [95 to 1065 kg CH 4/hr, 95% CI], or 1% [0.2%more » to 2.6%] of all methane emissions measured during a prior aircraft study of the same area. Emissions estimated by this study fall within the uncertainty range of emissions estimated using emission factors from EPA's 2015 Greenhouse Inventory and study activity estimates. While EPA's current inventory is based upon emission factors from distribution mains measured in the 1990s, this study indicates that using emission factors from more recent distribution studies could significantly underestimate emissions from gathering pipelines. To guide broader studies of pipeline emissions, we also estimate the fraction of the pipeline length within a basin that must be measured to constrain uncertainty of pipeline emissions estimates to within 1% of total basin emissions. The study provides both substantial insight into the mix of emission sources and guidance for future gathering pipeline studies, but since measurements were made in a single basin, the results are not sufficiently representative to provide methane emission factors at the regional or national level.« less

  19. Capsule Escape Tests - Wallops Island

    NASA Image and Video Library

    1959-05-14

    Caption: Off the pad abort shot at Wallops using Langley PARD designed full scale capsule with Recruit rocket and extended skirt main parachute. Shows sequential images of launch and capsule splashdown.

  20. Contraception with subdermal ST-1435 capsules: side-effects, endocrine profiles and liver function related to different lengths of capsules.

    PubMed

    Kurunmäki, H; Toivonen, J; Lähteenmäki, P; Luukkainen, T

    1985-03-01

    One Silastic capsule of 15 mm, 20 mm or 30 mm length was inserted subcutaneously into the ventral aspect of the left forearm or upper arm of 28 healthy women during menstrual bleeding or not later than on the seventh day of the menstrual cycle. A new capsule of the same length was inserted after six months and both capsules were removed twelve months after the first insertion. Side-effects, including changes in body weight, blood pressure, menstrual bleeding and liver function test results, were registered. Blood samples were taken from selected subjects twice a week during the 1st, 2nd, 3rd, 6th, 7th and 12th month of use. Plasma concentrations of ST-1435 were measured by radioimmunoassay and the effects of treatment on pituitary and ovarian function were determined by assaying plasma concentrations of LH, FSH, estradiol and progesterone. There were no differences in hormonal side-effects between subjects who had a 30 mm capsule or subjects who had 20 mm or 15 mm capsules, but subjects who had 20 or 15 mm capsules had significantly longer bleeding or spotting periods in comparison with subjects who had a 30 mm capsule. There were no changes in blood pressure, body weight or liver function test results in comparison with pre-insertion values. The plasma level of ST-1435 was not significantly higher during the use of 30 mm capsules than during the use of 20 or 15 mm capsules. During the use of the shorter ST-1435 capsules, plasma estradiol elevation and slightly suppressed FSH were seen, while the use of longer capsules resulted in a slight suppression of LH. Progesterone concentrations during monitored cycles indicated anovulation. No pregnancies occurred during the study period of one year. The continuation rate at one year was 71% in the 30 mm capsule group and 57% in the 20 and 15 mm capsule groups taken together.

  1. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  2. Design of a Soft Robot with Multiple Motion Patterns Using Soft Pneumatic Actuators

    NASA Astrophysics Data System (ADS)

    Miao, Yu; Dong, Wei; Du, Zhijiang

    2017-11-01

    Soft robots are made of soft materials and have good flexibility and infinite degrees of freedom in theory. These properties enable soft robots to work in narrow space and adapt to external environment. In this paper, a 2-DOF soft pneumatic actuator is introduced, with two chambers symmetrically distributed on both sides and a jamming cylinder along the axis. Fibers are used to constrain the expansion of the soft actuator. Experiments are carried out to test the performance of the soft actuator, including bending and elongation characteristics. A soft robot is designed and fabricated by connecting four soft pneumatic actuators to a 3D-printed board. The soft robotic system is then established. The pneumatic circuit is built by pumps and solenoid valves. The control system is based on the control board Arduino Mega 2560. Relay modules are used to control valves and pressure sensors are used to measure pressure in the pneumatic circuit. Experiments are conducted to test the performance of the proposed soft robot.

  3. A pneumatic cylinder driving polyhedron mobile mechanism

    NASA Astrophysics Data System (ADS)

    Ding, Wan; Kim, Sung-Chan; Yao, Yan-An

    2012-03-01

    A novel pneumatic cylinder driving polyhedron mobile mechanism is proposed in this paper. The mechanism is comprised of 5 tetrahedrons which includes a pneumatic cylinder in each edge. It locomotes by rolling and the rolling principle refers to the center of mass (CM) of the mechanism moved out of the supporting area and let it tip over through the controlling of the motion sequence of these cylinders. Firstly, the mathematical model is built to analysis the relation between the configuration and the CM of the mechanism. Then, a binary control strategy is developed to simplify and improve the control of this mobile mechanism. After that, dynamic simulation is performed to testify the analytical validity and feasibility of the rolling gaits. At last, a prototype is fabricated to achieve the rolling successfully to demonstrate the proposed concept.

  4. Pneumatics. Student's Manual [and] Instructor's Guide.

    ERIC Educational Resources Information Center

    Notgrass, Troy

    The student's manual in this two-part instructional kit is designed to help the following types of students learn introductory technical material related to pneumatics: (1) groups of trade and industrial students with a variety of vocational objectives and (2) homogeneous groups in which the learning levels of individual students vary…

  5. A reduced-order model-based study on the effect of intermittent pneumatic compression of limbs on the cardiovascular system.

    PubMed

    Maffiodo, Daniela; De Nisco, Giuseppe; Gallo, Diego; Audenino, Alberto; Morbiducci, Umberto; Ferraresi, Carlo

    2016-04-01

    This work investigates the effect that the application of intermittent pneumatic compression to lower limbs has on the cardiovascular system. Intermittent pneumatic compression can be applied to subjects with reduced or null mobility and can be useful for therapeutic purposes in sports recovery, deep vein thrombosis prevention and lymphedema drainage. However, intermittent pneumatic compression performance and the effectiveness are often difficult to predict. This study presents a reduced-order numerical model of the interaction between the cardiovascular system and the intermittent pneumatic compression device. The effect that different intermittent pneumatic compression operating conditions have on the overall circulation is investigated. Our findings confirm (1) that an overall positive effect on hemodynamics can be obtained by properly applying the intermittent pneumatic compression device and (2) that using intermittent pneumatic compression for cardiocirculatory recovery is feasible in subjects affected by lower limb disease. © IMechE 2016.

  6. 77 FR 34123 - Pipeline Safety: Public Meeting on Integrity Management of Gas Distribution Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-08

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2012-0100] Pipeline Safety: Public Meeting on Integrity Management of Gas Distribution Pipelines AGENCY: Office of Pipeline Safety, Pipeline and Hazardous Materials Safety Administration, DOT. ACTION...

  7. ALMA Pipeline: Current Status

    NASA Astrophysics Data System (ADS)

    Shinnaga, H.; Humphreys, E.; Indebetouw, R.; Villard, E.; Kern, J.; Davis, L.; Miura, R. E.; Nakazato, T.; Sugimoto, K.; Kosugi, G.; Akiyama, E.; Muders, D.; Wyrowski, F.; Williams, S.; Lightfoot, J.; Kent, B.; Momjian, E.; Hunter, T.; ALMA Pipeline Team

    2015-12-01

    The ALMA Pipeline is the automated data reduction tool that runs on ALMA data. Current version of the ALMA pipeline produces science quality data products for standard interferometric observing modes up to calibration process. The ALMA Pipeline is comprised of (1) heuristics in the form of Python scripts that select the best processing parameters, and (2) contexts that are given for book-keeping purpose of data processes. The ALMA Pipeline produces a "weblog" that showcases detailed plots for users to judge how each step of calibration processes are treated. The ALMA Interferometric Pipeline was conditionally accepted in March 2014 by processing Cycle 0 and Cycle 1 data sets. From Cycle 2, ALMA Pipeline is used for ALMA data reduction and quality assurance for the projects whose observing modes are supported by the ALMA Pipeline. Pipeline tasks are available based on CASA version 4.2.2, and the first public pipeline release called CASA 4.2.2-pipe has been available since October 2014. One can reduce ALMA data both by CASA tasks as well as by pipeline tasks by using CASA version 4.2.2-pipe.

  8. First order capsules comparative arrangements

    NASA Technical Reports Server (NTRS)

    1963-01-01

    Pen and ink views of comparative arragements of several capsules including the existing 'Big Joe' design, the compromise 'Big Joe' design, and the 'Little Joe'. All capsule designs are labeled and include dimensions.

  9. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    PubMed

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  10. Nanocomposite capsules with directional, pulsed nanoparticle release.

    PubMed

    Udoh, Christiana E; Cabral, João T; Garbin, Valeria

    2017-12-01

    The precise spatiotemporal delivery of nanoparticles from polymeric capsules is required for applications ranging from medicine to materials science. These capsules derive key performance aspects from their overall shape and dimensions, porosity, and internal microstructure. To this effect, microfluidics provide an exceptional platform for emulsification and subsequent capsule formation. However, facile and robust approaches for nanocomposite capsule fabrication, exhibiting triggered nanoparticle release, remain elusive because of the complex coupling of polymer-nanoparticle phase behavior, diffusion, phase inversion, and directional solidification. We investigate a model system of polyelectrolyte sodium poly(styrene sulfonate) and 22-nm colloidal silica and demonstrate a robust capsule morphology diagram, achieving a range of internal morphologies, including nucleated and bicontinuous microstructures, as well as isotropic and non-isotropic external shapes. Upon dissolution in water, we find that capsules formed with either neat polymers or neat nanoparticles dissolve rapidly and isotropically, whereas bicontinuous, hierarchical, composite capsules dissolve via directional pulses of nanoparticle clusters without disrupting the scaffold, with time scales tunable from seconds to hours. The versatility, facile assembly, and response of these nanocomposite capsules thus show great promise in precision delivery.

  11. Rod-based Fabrication of Customizable Soft Robotic Pneumatic Gripper Devices for Delicate Tissue Manipulation.

    PubMed

    Low, Jin-Huat; Yeow, Chen-Hua

    2016-08-02

    Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage.

  12. Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber

    NASA Astrophysics Data System (ADS)

    Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan

    2013-12-01

    This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston-cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed.

  13. Gelatin capsule in stomach (image)

    MedlinePlus

    ... detect the presence of intestinal parasites. A weighted gelatin capsule attached to a string is swallowed and left in place. After about 4 hours, the gelatin capsule is pulled out of the stomach by ...

  14. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... surgical drill. 874.4250 Section 874.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH....4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose, and throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that...

  15. Thermoregulation of Capsule Production by Streptococcus pyogenes

    PubMed Central

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  16. Big Joe Capsule Assembly Activities

    NASA Image and Video Library

    1959-08-01

    Big Joe Capsule Assembly Activities in 1959 at NASA Glenn Research Center (formerly NASA Lewis). Big Joe was an Atlas missile that successfully launched a boilerplate model of the Mercury capsule on September 9, 1959.

  17. The effects of hematoma on implant capsules.

    PubMed

    Caffee, H H

    1986-02-01

    Hematoma surrounding an implant is one of the many factors that have been suggested as possible causes for scar capsule contracture. In this study, experiments were designed to determine the influence of hematoma on the incidence and severity of capsule contracture in rabbits. Two implants were placed in each animal, 1 with a surrounding hematoma and 1 control. Capsules were evaluated subjectively and compared objectively with measurements of deformability, surface area, and capsule thickness. No differences were found with any of the objective criteria, which suggests that hematoma may not be a noteworthy cause of implant capsule contracture.

  18. Active Control of a Pneumatic Isolation System,

    DTIC Science & Technology

    A pneumatically isolated test platform has been modified to provide active control to the local gravity vector. A combination of sensors , including... tiltmeters , angular accelerometers, seismometers, and a gyrocompass measure total platform motion between 0 and 100 Hz. Electrical-to-pressure

  19. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetjuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  20. 75 FR 5244 - Pipeline Safety: Integrity Management Program for Gas Distribution Pipelines; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-02

    ... Management Program for Gas Distribution Pipelines; Correction AGENCY: Pipeline and Hazardous Materials Safety... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... Regulations to require operators of gas distribution pipelines to develop and implement integrity management...

  1. Stennis time capsule

    NASA Image and Video Library

    2011-10-15

    Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary. NASA publicly announced plans to build the rocket engine test site Oct. 25, 1961.

  2. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    PubMed

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  3. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  4. Small intestinal model for electrically propelled capsule endoscopy

    PubMed Central

    2011-01-01

    The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD) velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule. PMID:22177218

  5. Contraindications for video capsule endoscopy

    PubMed Central

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn’s disease, clinical signs of obstruction, prior radiation or surgical small bowel resection, a preceding test with the self-dissolving patency capsule can override this contraindication. Endoscopic placement of the capsule should be considered in patients with swallowing disorders to avoid aspiration. Esophageal or gastric motility disorders may require endoscopic capsule transport or application of prokinetics if the real-time viewer proofs delayed transit. In pregnant women, VCE should be restricted to urgent cases where diagnosis cannot be postponed after delivery, as data on safety are missing. There is theoretical and clinical evidence that patients with implanted cardiac devices such as a pacemaker, cardioverters or left heart assist devices, can safely undergo VCE in spite of still existing contraindication by manufacturers. Children from the age of 2 years have safely undergone VCE. Although video capsules are not proven safe with magnetic resonance imaging (MRI), first single cases of patients incidentally undergoing MRI with an incorporated capsule have been reported, showing susceptibility artifacts but no signs of clinical harm. PMID:28018097

  6. Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.

    1998-01-01

    In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored

  7. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...

  8. Basic ammonothermal GaN growth in molybdenum capsules

    NASA Astrophysics Data System (ADS)

    Pimputkar, S.; Speck, J. S.; Nakamura, S.

    2016-12-01

    Single crystal, bulk gallium nitride (GaN) crystals were grown using the basic ammonothermal method in a high purity growth environment created using a non-hermetically sealed molybdenum (Mo) capsule and compared to growths performed in a similarly designed silver (Ag) capsule and capsule-free René 41 autoclave. Secondary ion mass spectrometry (SIMS) analysis revealed transition metal free (<1×1017 cm-3) GaN crystals. Anomalously low oxygen concentrations ((2-6)×1018 cm-3) were measured in a {0001} seeded crystal boule grown using a Mo capsule, despite higher source material oxygen concentrations ((1-5)×1019 cm-3) suggesting that molybdenum (or molybdenum nitrides) may act to getter oxygen under certain conditions. Total system pressure profiles from growth runs in a Mo capsule system were comparable to those without a capsule, with pressures peaking within 2 days and slowly decaying due to hydrogen diffusional losses. Measured Mo capsule GaN growth rates were comparable to un-optimized growth rates in capsule-free systems and appreciably slower than in Ag-capsule systems. Crystal quality replicated that of the GaN seed crystals for all capsule conditions, with high quality growth occurring on the (0001) Ga-face. Optical absorption and impurity concentration characterization suggests reduced concentrations of hydrogenated gallium vacancies (VGa-Hx).

  9. Design and analysis of non-pneumatic tyre

    NASA Astrophysics Data System (ADS)

    Mohan, Aravind; Johny, C. Ajith; Tamilarasu, A.; Pradeep Bhasker, J.; Ravi, K.

    2017-11-01

    Non-Pneumatic Tyre (NPT) as the name suggests is a type of tyre that doesn't use air to support the load. Even though tyres made out of solid rubber exists, they don't have enough compliance and will not provide a supple ride if used in normal vehicles. The NPT discussed here consists of mainly three parts. A rigid hub, Deformable spokes that support vertical load, Reinforced shear band and tread made out of rubber which comes into contact with the surface. The properties of NPT like contact pressure, rolling resistance and load carrying capacity can be varied by altering the dimensions or materials used to manufacture NPT. Several researches are being carried out all over the globe to make NPT an alternative to the conventional pneumatic tyre. This paper consolidates an overview of the research works that were carried out to develop and improve NPT.

  10. Pneumatic load compensating or controlling system

    NASA Technical Reports Server (NTRS)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  11. Initial experimental evaluation of wireless capsule endoscopes in the bladder: implications for capsule cystoscopy.

    PubMed

    Gettman, Matthew T; Swain, Paul

    2009-05-01

    Cystoscopy remains one of the most important diagnostic procedures for the lower urinary tract. Wireless capsule endoscopy was introduced in the 1990s but use to date is limited to gastroenterology. We evaluated the feasibility in the pig model of using wireless capsule endoscopes (WCEs) for cystoscopy. Experimental evaluation of capsule cystoscopy was performed in a 50-kg farm pig. The capsule was deployed into the bladder through a custom access sheath. Images were continuously transmitted at a rate of four frames per second to a laptop computer and processed using proprietary software. Manipulation of the WCE within the bladder was performed using a set protocol. The animal was then euthanized and gross inspection was performed. We measured the ability to deploy and manipulate the capsule within the bladder. Feasibility of capturing and retrieving images in real time was also assessed. The WCE was efficiently deployed and manipulated within the bladder passively and with the use of external magnets. The entire bladder mucosa was visualized. Real-time image transmission and capture were successful. No complications were seen during capsule cystoscopy. Minor urethral bleeding was observed after the experiment, likely related to placement of the access sheath required for deployment of the WCE. Limitations are that the evaluation of WCE was performed in the pig model, in only one female animal, using a nonsurvival approach. Furthermore, the study was not designed to differentiate normal from abnormal mucosal findings and focused solely on inspection of the bladder. This report suggests that cystoscopy with a WCE is feasible. With this device, all aspects of the bladder mucosa could be visualized, and ongoing technologic and procedural developments are warranted for this new approach.

  12. Anterior capsule relaxing incisions with neodymium:YAG laser for patients at high-risk for anterior capsule contraction.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hirata, Akira; Hayashi, Hideyuki

    2011-01-01

    To examine the effect of anterior capsule relaxing incisions created with a neodymium:YAG (Nd:YAG) laser on prevention of anterior capsule contraction after cataract surgery in high-risk patients. Hayashi Eye Hospital, Fukuoka, Japan. Randomized masked clinical trials. Patients at high risk for anterior capsule contraction had anterior capsule relaxing incisions in either eye 3 days postoperatively. The anterior capsule opening was measured using a Scheimpflug videophotography system (EAS-1000) immediately and 1, 3, and 6 months after capsulotomy, and the percentage reduction in area was calculated. The degree of intraocular lens (IOL) decentration and tilt, posterior capsule opacification (PCO), and other complications were also assessed. Of the 84 patients included, 30 had primary angle closure, 28 had pseudoexfoliation, and 26 had diabetic retinopathy. There was no significant difference in the mean opening area between fellow eyes at baseline. In patients with primary angle closure, the area was significantly greater and the percentage reduction in area was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0428). In patients with pseudoexfoliation or diabetic retinopathy, the percentage reduction was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0493), although there was no significant difference in area. No significant difference was found in IOL decentration or tilt, PCO, or incidence of other complications. Neodymium:YAG laser anterior capsule relaxing incisions in the early period after cataract surgery were effective in preventing anterior capsule contraction in high-risk patients and had no adverse effects. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Development of a pneumatic tensioning device for gap measurement during total knee arthroplasty.

    PubMed

    Kwak, Dai-Soon; Kong, Chae-Gwan; Han, Seung-Ho; Kim, Dong-Hyun; In, Yong

    2012-09-01

    Despite the importance of soft tissue balancing during total knee arthroplasty (TKA), all estimating techniques are dependent on a surgeon's manual distraction force or subjective feeling based on experience. We developed a new device for dynamic gap balancing, which can offer constant load to the gap between the femur and tibia, using pneumatic pressure during range of motion. To determine the amount of distraction force for the new device, 3 experienced surgeons' manual distraction force was measured using a conventional spreader. A new device called the consistent load pneumatic tensor was developed on the basis of the biomechanical tests. Reliability testing for the new device was performed using 5 cadaveric knees by the same surgeons. Intraclass correlation coefficients (ICCs) were calculated. The distraction force applied to the new pneumatic tensioning device was determined to be 150 N. The interobserver reliability was very good for the newly tested spreader device with ICCs between 0.828 and 0.881. The new pneumatic tensioning device can enable us to properly evaluate the soft tissue balance throughout the range of motion during TKA with acceptable reproducibility.

  14. Endoscopic Pneumatic Dilation for Esophageal Achalasia.

    PubMed

    Markar, Sheraz; Zaninotto, Giovanni

    2018-04-01

    Pneumatic dilation is a well-established treatment modality that has withstood the test of time. Prospective and randomized trials have shown that in expert hands, it provides results similar to a laparoscopic Heller myotomy with fundoplication. In addition, it should be considered the primary form of treatment in patients who experience recurrence of symptoms after a surgical myotomy.

  15. Improved third generation peristaltic crawler for removal of high-level waste plugs in United States department of energy Hanford site pipelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vazquez, Gabriela; Pribanic, Tomas

    2013-07-01

    There are approximately 56 million gallons (212 km{sup 3}) of high level waste (HLW) at the U.S. Department of Energy (DOE) Hanford Site. It is scheduled that by the year 2040, the HLW is to be completely transferred to secure double-shell tanks (DST) from the leaking single-tanks (SST) via transfer pipeline system. Blockages have formed inside the pipes during transport because of the variety in composition and characteristics of the waste. These full and partial plugs delay waste transfers and require manual intervention to repair, therefore are extremely expensive, consuming millions of dollars and further threatening the environment. To successfullymore » continue the transfer of waste through the pipelines, DOE site engineers are in need of a technology that can accurately locate the blockages and unplug the pipelines. In this study, the proposed solution to remediate blockages formed in pipelines is the use of a peristaltic crawler: a pneumatically/hydraulically operated device that propels itself in a worm-like motion through sequential fluctuations of pressure in its air cavities. The crawler is also equipped with a high-pressure water nozzle used to clear blockages inside the pipelines. The crawler is now in its third generation. Previous generations showed limitations in its durability, speed, and maneuverability. Latest improvements include an automation of sequence that prevents kickback, a front-mounted inspection camera for visual feedback, and a thinner wall outer bellow for improved maneuverability. Different experimental tests were conducted to evaluate the improvements of crawler relative to its predecessors using a pipeline test-bed assembly. Anchor force tests, unplugging tests, and fatigue testing for both the bellow and rubber rims have yet to be conducted and thus results are not presented in this research. Experiments tested bellow force and response, cornering maneuverability, and straight line navigational speed. The design concept and

  16. Reinforcing effects of caffeine in coffee and capsules.

    PubMed

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.

  17. Reinforcing effects of caffeine in coffee and capsules.

    PubMed Central

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-01-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839

  18. Sensor capsule for diagnosis of gastric disorders

    NASA Technical Reports Server (NTRS)

    Holen, J. T.

    1972-01-01

    Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.

  19. Capsule endoscopy: no longer limited to the small bowel.

    PubMed

    Niv, Yaron

    2010-03-01

    Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.

  20. 78 FR 41991 - Pipeline Safety: Potential for Damage to Pipeline Facilities Caused by Flooding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-12

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No...: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice; Issuance of Advisory... Gas and Hazardous Liquid Pipeline Systems. Subject: Potential for Damage to Pipeline Facilities Caused...

  1. Structure and Composition of the Bacillus anthracis Capsule

    PubMed Central

    Avakyan, A. A.; Katz, L. N.; Levina, K. N.; Pavlova, I. B.

    1965-01-01

    Avakyan, A. A. (Academy of Medical Sciences, Moscow, USSR), L. N. Katz, K. N. Levina, and I. B. Pavlova. Structure and composition of the Bacillus anthracis capsule. J. Bacteriol. 90:1082–1095. 1965.—Observations by various methods of light microscopy (phase contrast, dark-field, and fluorescence) revealed the complex structure of the Bacillus anthracis capsule, which changes regularly during the growth cycle of the culture. Special cytological methods of staining the capsule made it possible to study its fine structure, which is not revealed by negative staining with India ink. For example, the capsule shows a membranelike outline, fine transverse lines, and interruptions and transverse septa traversing the entire capsule. By using cytochemical methods, it was found that the capsule has a stratified structure and that the various layers of the capsule differ as to the value of the isoelectric point, metachromatic ability, sensitivity to various enzymes, and, consequently, chemical composition. It was thus shown that the membranelike outline of the capsule consists of peptides and neutral mucopolysaccharides. The middle part of the capsule consists of a complex of substances of both polysaccharide and protein nature, and the inner part consists of acid mucopolysaccharides. Observation of the capsular forms of B. anthracis by means of an electron microscope revealed differences in the osmiophilia and submicroscopic structure of the membranelike outline and the middle and inner parts of the capsule. Immunochemical studies conducted by the fluorescent-antibody method revealed localization of antigens in different parts of the capsule, and made it possible to differentiate the capsular antigens according to their serum-staining ability and according of their relations to enzymes, i.e., their chemical composition. This paper concerns the possibility of studying the fine structure of bacterial capsules in fixed preparations, and the differences and similarities of

  2. 78 FR 41496 - Pipeline Safety: Meetings of the Gas and Liquid Pipeline Advisory Committees

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2013-0156] Pipeline Safety: Meetings of the Gas and Liquid Pipeline Advisory Committees AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice of advisory committee...

  3. A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.

    PubMed

    Ahmadi, Farzaneh; Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.

  4. A New Family of Capsule Polymerases Generates Teichoic Acid-Like Capsule Polymers in Gram-Negative Pathogens.

    PubMed

    Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm

    2018-05-29

    Group 2 capsule polymers represent crucial virulence factors of Gram-negative pathogenic bacteria. They are synthesized by enzymes called capsule polymerases. In this report, we describe a new family of polymerases that combine glycosyltransferase and hexose- and polyol-phosphate transferase activity to generate complex poly(oligosaccharide phosphate) and poly(glycosylpolyol phosphate) polymers, the latter of which display similarity to wall teichoic acid (WTA), a cell wall component of Gram-positive bacteria. Using modeling and multiple-sequence alignment, we showed homology between the predicted polymerase domains and WTA type I biosynthesis enzymes, creating a link between Gram-negative and Gram-positive cell wall biosynthesis processes. The polymerases of the new family are highly abundant and found in a variety of capsule-expressing pathogens such as Neisseria meningitidis , Actinobacillus pleuropneumoniae , Haemophilus influenzae , Bibersteinia trehalosi , and Escherichia coli with both human and animal hosts. Five representative candidates were purified, their activities were confirmed using nuclear magnetic resonance (NMR) spectroscopy, and their predicted folds were validated by site-directed mutagenesis. IMPORTANCE Bacterial capsules play an important role in the interaction between a pathogen and the immune system of its host. During the last decade, capsule polymerases have become attractive tools for the production of capsule polymers applied as antigens in glycoconjugate vaccine formulations. Conventional production of glycoconjugate vaccines requires the cultivation of the pathogen and thus the highest biosafety standards, leading to tremendous costs. With regard to animal husbandry, where vaccines could avoid the extensive use of antibiotics, conventional production is not sufficiently cost-effective. In contrast, enzymatic synthesis of capsule polymers is pathogen-free and fast, offers high stereo- and regioselectivity, and works with high efficacy

  5. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...

  6. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...

  7. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 6 2014-10-01 2014-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...

  8. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...

  9. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  10. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  11. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  12. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  13. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  14. Oxygen fugacity and piston cylinder capsule assemblies

    NASA Astrophysics Data System (ADS)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  15. Laboratory-based ROTEM(®) analysis: implementing pneumatic tube transport and real-time graphic transmission.

    PubMed

    Colucci, G; Giabbani, E; Barizzi, G; Urwyler, N; Alberio, L

    2011-08-01

    ROTEM(®) is considered a helpful point-of-care device to monitor blood coagulation. Centrally performed analysis is desirable but rapid transport of blood samples and real-time transmission of graphic results are an important prerequisite. The effect of sample transport through a pneumatic tube system on ROTEM(®) results is unknown. The aims of the present work were (i) to determine the influence of blood sample transport through a pneumatic tube system on ROTEM(®) parameters compared to manual transportation, and (ii) to verify whether graphic results can be transmitted on line via virtual network computing using local area network to the physician in charge of the patient. Single centre study with 30 normal volunteers. Two whole blood samples were transferred to the central haematology laboratory by either normal transport or pneumatic delivery. EXTEM, INTEM, FIBTEM and APTEM were analysed in parallel with two ROTEM(®) devices and compared. Connection between central laboratory, emergency and operating rooms was established using local area network. All collected ROTEM(®) parameters were within normal limits. No statistically significant differences between normal transport and pneumatic delivery were observed. Real-time transmission of the original ROTEM(®) curves using local area network is feasible and easy to establish. At our institution, transport of blood samples by pneumatic delivery does not influence ROTEM(®) parameters. Blood samples can be analysed centrally, and results transmitted live via virtual network computing to emergency or operating rooms. Prior to analyse blood samples centrally, the type of sample transport should be tested to exclude in vitro blood activation by local pneumatic transport system. © 2011 Blackwell Publishing Ltd.

  16. Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.

    PubMed

    Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly

    2013-01-01

    The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.

  17. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-pneumatic tire assembly incorporates a wheel, supports the tire, and attaches, either integrally or... directly or through a wheel or wheel center member, the vertical load and tractive forces from the roadway... assembly means a non-pneumatic tire, alone or in combination with a wheel or wheel center member, which can...

  18. Vortex rings from Sphagnum moss capsules

    NASA Astrophysics Data System (ADS)

    Whitaker, Dwight; Strassman, Sam; Cha, Jung; Chang, Emily; Guo, Xinyi; Edwards, Joan

    2010-11-01

    The capsules of Sphagnum moss use vortex rings to disperse spores to suitable habitats many kilometers away. Vortex rings are created by the sudden release of pressurized air when the capsule ruptures, and are an efficient way to carry the small spores with low terminal velocities to heights where they can be carried by turbulent wind currents. We will present our computational model of these explosions, which are carried out using a 2-D large eddy simulation (LES) on FLUENT. Our simulations can reproduce the observed motion of the spore clouds observed from moss capsules with high-speed videos, and we will discuss the roles of bursting pressure, cap mass, and capsule morphology on the formation and quality of vortex rings created by this plant.

  19. Polyelectrolyte multilayer capsules as vehicles with tunable permeability.

    PubMed

    Antipov, Alexei A; Sukhorukov, Gleb B

    2004-11-29

    This review is devoted to a novel type of polymer micro- and nanocapsules. The shell of the capsule is fabricated by alternate adsorption of oppositely charged polyelectrolytes (PEs) onto the surface of colloidal particles. Cores of different nature (organic or inorganic) with size varied from 0.1 to 10 mum can be used for templating such PE capsules. The shell thickness can be tuned in nanometer range by assembling of defined number of PE layers. The permeability of capsules depends on the pH, ionic strength, solvent, polymer composition, and shell thickness; it can be controlled and varied over wide range of substances regarding their molecular weight and charge. Including functional polymers into capsule wall, such as weak PEs or thermosensitive polymers, makes the capsule permeability sensitive to correspondent external stimuli. Permeability of the capsules is of essential interest in diverse areas related to exploitation of systems with controlled and sustained release properties. The envisaged applications of such capsules/vesicles cover biotechnology, medicine, catalysis, food industry, etc.

  20. Cell cycle constraints on capsulation and bacteriophage susceptibility.

    PubMed

    Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H

    2014-11-25

    Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity.

  1. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  2. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  3. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  4. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  5. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  6. Discussion on a Potential DJ Basin Pneumatic Controller ...

    EPA Pesticide Factsheets

    ORD NRMRL and Region 8 collaborators are conducting emission measurements and method development studies on pneumatic controllers (PCs) in the Uintah Basin, Utah (and potentially in Colorado), in cooperation with Oil and Natural gas (ONG) operators. ONG operations use PCs for production process control and safety functions. PCs emit gas to the atmosphere as they operate and sometimes they malfunction and emit more than they are supposed to. Because of the very large number of PCs in use, these devices contribute significantly to greenhouse gas (GHG) and volatile organic compound (VOC) emissions. There is considerable uncertainty in levels of real-world PC emissions and measurement methods for PCs are somewhat underdeveloped. In collaboration with EPA R8, the State of Colorado, (and industry participants in Step 2), ORD NRMRL is evaluating a potential follow-on research effort to the Uinta Basin Pneumatic Controller (PC) Study. The Uinta PC Study is described in a recent APPCD Research Highlight (attached )with results summarized in “Assessment of Uinta Basin Oil and Natural Gas Well Pad Pneumatic Controller Emissions”, E. Thoma et al., Journal of Environmental Protection, 8, 394-415, (2017). doi: 10.4236/jep.2017.84029; at (http://www.scirp.org/Journal/PaperInformation.aspx?PaperID=75669). This RAP research was funded by an EPA R8 RARE and ACE Task EM 1.2 (next gen. emissions measurements). For both technical and programmatic reasons, we seek to

  7. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system.

    PubMed

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-01

    Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. 76 FR 29333 - Pipeline Safety: Meetings of the Technical Pipeline Safety Standards Committee and the Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-20

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... Technical Hazardous Liquid Pipeline Safety Standards Committee AGENCY: Pipeline and Hazardous Materials... for natural gas pipelines and for hazardous liquid pipelines. Both committees were established under...

  9. Biomimetic/Bioinspired Design of Enzyme@capsule Nano/Microsystems.

    PubMed

    Shi, J; Jiang, Y; Zhang, S; Yang, D; Jiang, Z

    2016-01-01

    Enzyme@capsule nano/microsystems, which refer to the enzyme-immobilized capsules, have received tremendous interest owing to the combination of the high catalytic activities of encapsulated enzymes and the hierarchical structure of the capsule. The preparation of capsules and simultaneous encapsulation of enzymes is recognized as the core process for the rational design and construction of enzyme@capsule nano/microsystems. The strategy used has three major steps: (a) generation of the templates, (b) surface coating on the templates, and (c) removal of the templates, and it has been proven to be effective and versatile for the construction of enzyme@capsule nano/microsystems. Several conventional methods, including layer-by-layer assembly of polyelectrolytes, liquid crystalline templating method, etc., were used to design and construct enzyme@capsule nano/microsystems, but these have two major drawbacks. One is the low mechanical stability of the systems and the second is the harsh conditions used in the construction process. Learning from nature, several biomimetic/bioinspired methods such as biomineralization, biomimetic/bioinspired adhesion, and their combination have been exploited for the construction of enzyme@capsule nano/microsystems. In this chapter, we will present a general protocol for the construction of enzyme@capsule nano/microsystems using the latter approach. Some suggestions for improved design, construction, and characterization will also be presented with detailed procedures for specific examples. © 2016 Elsevier Inc. All rights reserved.

  10. 76 FR 43743 - Pipeline Safety: Meetings of the Technical Pipeline Safety Standards Committee and the Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-21

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2011-0127] Pipeline Safety: Meetings of the Technical Pipeline Safety Standards Committee and the Technical Hazardous Liquid Pipeline Safety Standards Committee AGENCY: Pipeline and Hazardous Materials...

  11. [Pneumatic dilation in the treatment of achalasia].

    PubMed

    Ruiz Cuesta, Patricia; Hervás Molina, Antonio José; Jurado García, Juan; Pleguezuelo Navarro, María; García Sánchez, Valle; Casáis Juanena, Luis L; Gálvez Calderón, Carmen; Naranjo Rodríguez, Antonio

    2013-10-01

    Pneumatic dilation and surgical myotomy are currently the procedures of choice to treat achalasia. The selection of one or other treatment depends on the experience of each center and patient preferences. To review the experience of pneumatic dilation in patients with achalasia in our center. We included all patients with a clinical, endoscopic and manometric diagnosis compatible with achalasia who underwent pneumatic dilation in a 19-year period. All dilations were routinely performed with a Rigiflex(®) balloon, usually at pressures of 250, 250 and 300mm Hg in three inflations of one minute, each separated by one minute. The success of the dilation was assessed on the basis of the patient's symptoms, the number of sessions, the need for surgery, and the presence of complications. A total of 171 patients were included, 53.2% men and 46.8% women, with a mean age of 51.53±17.78 years (16-87 years), from June 1993 to October 2012. A 35-mm balloon was used in 157 patients, a 30-mm balloon in 9 patients and a 40-mm balloon in 7 patients. A single dilation session was required in 108 patients, two sessions were required in 56 patients, with a mean time between the first and second sessions of 25.23±43.25 months (1-215 months), and 3 sessions were required in 7 patients with a mean time between the second and third sessions of 6.86±5.33 months (1-15 months). Outcome after dilation was successful in 81% of the patients. Of the 140 responders, 121 had complete response (complete disappearance of symptoms without recurrence) and 19 partial response (initial disappearance of symptoms with subsequent reappearance). Surgery (Heller myotomy) was required in 15.8% of the patients. Perforation occurred in 4 of the 171 patients as a complication of the technique; these perforations were satisfactorily resolved, two by conservative treatment and two by surgery. There was no mortality associated with the technique or its complications. In our series, pneumatic dilation had a

  12. 77 FR 16471 - Pipeline Safety: Implementation of the National Registry of Pipeline and Liquefied Natural Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-21

    ... Registry of Pipeline and Liquefied Natural Gas Operators AGENCY: Pipeline and Hazardous Materials Safety... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Parts... Register (75 FR 72878) titled: ``Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting...

  13. 3D Printed Programmable Release Capsules.

    PubMed

    Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C

    2015-08-12

    The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients.

  14. A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset

    PubMed Central

    Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech. PMID:29466455

  15. Characteristics of patients with a retained wireless capsule endoscope (WCE) necessitating laparotomy for removal of the capsule.

    PubMed

    Purdy, Martin; Heikkinen, Markku; Juvonen, Petri; Voutilainen, Markku; Eskelinen, Matti

    2011-01-01

    A capsule endoscope is a wireless miniature camera used to take images of the small bowel mucosa. Retention of the wireless capsule endoscope (WCE), defined as at least two weeks' retention or an obstruction demanding removal by laparotomy, is the main and practically only complication of the procedure. The aim of this study was to evaluate the characteristics of patients with a retained WCE necessitating laparotomy for removal of the capsule or capsule fragments. The medical records of 555 patients who had undergone the WCE procedure over a 7-year period (2002-2008) were reviewed. The indications for the WCE procedure were, obscure gastrointestinal bleeding, Crohn's disease, abdominal pain and suspicion of malignancy. A retained WCE requiring operative treatment was found in 10 cases (in nine patients, twice in one patient). The WCE retention frequency of 1.8% (10/555) equalled that in the literature. The retention rate of WCE capsules is low and routine examination of the small bowel with MRI or CT is not necessary before WCE. These examinations were enable to predict WCE retention according to our results.

  16. Capsules made from prefabricated thin films

    NASA Astrophysics Data System (ADS)

    Amstad, Esther

    2018-02-01

    Capsules are composed of a core, typically a liquid containing active substances, and a surrounding shell. They are used to delay the degradation of active ingredients, protect them from reacting or interacting with substances contained in the surrounding shell, or to prevent premature consumption of encapsulants (1, 2). The performance of capsules is often determined by their permeability toward encapsulants and stability against rupture; these parameters can be adjusted with the composition, structure, and thickness of the shell (3, 4). Mechanically robust capsules with a minimal permeability even toward low molecular weight substances often have rather thick shells (5). On page 775 of this issue, Kumar et al. (6) report an elegant process to fabricate capsules with very thin, rigid shells that display a low permeability even toward small encapsulants.

  17. Treatment of ureteric calculi--use of Holmium: YAG laser lithotripsy versus pneumatic lithoclast.

    PubMed

    Tipu, Salman Ahmed; Malik, Hammad Afzal; Mohhayuddin, Nazim; Sultan, Gauhar; Hussain, Manzoor; Hashmi, Altaf; Naqvi, Syed Ali Anwar; Rizvi, Syed Adibul Hasan

    2007-09-01

    To compare the efficacy of Holmium: YAG laser and pneumatic lithoclast in treating ureteric calculi. The study included total of 100 patients divided into two equal groups of laser lithotripsy (LL) and pneumatic lithoclast (PL). Study was conducted between September 2006 and February 2007. Inclusion criteria were patients with a ureteric stone of size 1-2 cm and negative urine culture. An x-ray KUB was mandatory. IVU and CT pyelogram were also done when required. Procedures were done under general anaesthesia after a single dose of pre-operative antibiotic. A 7.5 Fr semi rigid ureteroscope was used for ureteroscopy in all cases. Holmium: YAG laser with 365 microm wide probe was employed in laser group and frequency was set between 5 and 10 Hz at a power of 10 to 15 W. Swiss lithoclast with single or multiple fire technique was used accordingly in PL group. Postoperatively patients underwent radiography and helical CT as required at 4th week of follow up to asses stone clearance. The mean patient age in LL and PL group was 38 +/- 10 and 40 +/- 10 years respectively. The male to female ratio and stone size were similar between the groups. Stone migration up in pelvicalyceal system occurred in two patients of LL group while in eight patients of PL group. JJ Stent was placed in 5(10%) patients in laser group where as 13 (26%) patients required it in pneumatic lithoclast group. Stone free rate at 4 weeks was 92% in laser group as compared to 82% in pneumatic lithoclast group. Hospital stay was more than 24 hours in 2 patients of laser group as compared to 5 patients of pneumatic lithoclast group. Complication rate was 4% in LL group whereas it was 14% in PL group. Holmium: YAG laser lithotripsy is a superior technology compared to pneumatic lithoclast in terms of rate of stone clearance and complications, especially in upper ureteric stones.

  18. Pneumatic Variable Series Elastic Actuator.

    PubMed

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  19. Pneumatic Variable Series Elastic Actuator

    PubMed Central

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-01-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on–off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator. PMID:27354755

  20. Pneumatic versus laser ureteroscopic lithotripsy: a comparison of initial outcomes and cost.

    PubMed

    Demir, Aslan; Karadağ, Mert Ali; Ceçen, Kurşat; Uslu, Mehmet; Arslan, Omer Erkam

    2014-11-01

    To audit the cost of laser versus pneumatic semirigid ureteroscopic lithotripsy and to analyze their relative initial outcomes and cost. Hundred and eighty-seven patients who underwent semirigid ureteroscopic lithotripsy were analyzed retrospectively in terms of age and sex of the patients; location and size of the stones; the type of probe and ancillary equipment such as guide wire, basket catheter, JJ stent requirements; irrigation amount; operation time; the cost of the anesthesia and further treatments such as a JJ stent removal operation and shock wave lithotripsy requirements and their costs. Two groups were formed based on this type of lithotripters, pneumatic and laser lithotripsy. Operation times (min.) in terms of the stone size, for stones <100 and >100 mm(2) were 20.75 ± 10.78 and 25.82 ± 14.23, respectively (p = 0.007). Operation times for the pneumatic and laser groups were 33.05 ± 11.36 and 15.25 ± 6.14, respectively (p < 0.05).The stone-free rates for pneumatic and laser groups were 89.6 % (n = 69) and 98.2 % (n = 108), respectively (p = 0.01). The mean cost of the operations for each of the study groups was 261.5 ± 66.13 and 311.7 ± 51.97 US$, respectively (p = 0.001). The mean cost in terms of the stone size, for stones <100 and >100 mm(2), was 272.86 ± 53.05 and 323.71 ± 66.88 US$, respectively (p = 0.01). It seems that usage of laser lithotripsy (LL) in patients with ureteral stones is more effective than pneumatic lithotripsy (PL) in terms of operation time and SF rate. On the other hand, the mean cost of LL seems to be more expensive than PL. Urologists should think these parameters before the choice of these two treatment modalities. The higher the effectiveness, the greater the cost.

  1. 75 FR 45591 - Pipeline Safety: Notice of Technical Pipeline Safety Advisory Committee Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-03

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... Committee Meetings AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION... safety standards, risk assessments, and safety policies for natural gas pipelines and for hazardous...

  2. [Evaluation of nopal capsules in diabetes mellitus].

    PubMed

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P < 0.01 glucose and cholesterol, P = NS triglycerides). In healthy individuals glycemia did not change with nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  3. Triggering vacuum capillaries for pneumatic pumping and metering liquids in point-of-care immunoassays.

    PubMed

    Weng, Kuo-Yao; Chou, Nien-Jen; Cheng, Jya-Wei

    2008-07-01

    An innovative vacuum capillary pneumatic actuation concept that can be used for point-of-care testing has been investigated. The vacuum glass capillaries are encapsulated within a laminated pouch and incorporated into the fluidic card. Vacuum glass capillaries broken by external force such as finger pressure, generate the pneumatic forces to induce liquid flow in the fluidic system. The sizes of vacuum capillary play a vital role in the pumping and metering functions of the system. The luteinizing hormone (LH) chromatographic immunoassay performances in the fluidic cards show consistency comparable to that obtained by manual micropipetting. The vacuum capillary pneumatic actuation will be applied in other complex handling step bioassays and lab-on-a-chip devices.

  4. Emerging Issues and Future Developments in Capsule Endoscopy

    PubMed Central

    Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro

    2015-01-01

    Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the scope of the procedure. This review outlines clinical standards of the technology as well as recent advances in CE research. Clinical capsule applications are discussed with respect to each portion of the gastrointestinal tract. Promising research efforts are presented with an emphasis on enabling active capsule locomotion. The presented studies suggest, in particular, that the most viable solution for active capsule manipulation is actuation of a capsule via exterior permanent magnet held by a robot. Developing capsule procedures adhering to current healthcare standards, such as enabling a tool channel or irrigation in a therapeutic device, is a vital phase in the adaptation of CE in the clinical setting. PMID:26028956

  5. Cell cycle constraints on capsulation and bacteriophage susceptibility

    PubMed Central

    Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H

    2014-01-01

    Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity. DOI: http://dx.doi.org/10.7554/eLife.03587.001 PMID:25421297

  6. Distortion Of Pressure Signals In Pneumatic Tubes

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William

    1993-01-01

    NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.

  7. Pneumatic binary encoder replaces multiple solenoid system

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Pneumatic binary encoder replaces solenoid system in the pilot stage of a digital actuator. The encoder operates in flip-flop manner to valve gas at either high or low pressures. By rotating the disk in a pinion-to-encoding gear ratio, six to eight adder circuits may be operated from single encoder.

  8. Multinode reconfigurable pipeline computer

    NASA Technical Reports Server (NTRS)

    Nosenchuck, Daniel M. (Inventor); Littman, Michael G. (Inventor)

    1989-01-01

    A multinode parallel-processing computer is made up of a plurality of innerconnected, large capacity nodes each including a reconfigurable pipeline of functional units such as Integer Arithmetic Logic Processors, Floating Point Arithmetic Processors, Special Purpose Processors, etc. The reconfigurable pipeline of each node is connected to a multiplane memory by a Memory-ALU switch NETwork (MASNET). The reconfigurable pipeline includes three (3) basic substructures formed from functional units which have been found to be sufficient to perform the bulk of all calculations. The MASNET controls the flow of signals from the memory planes to the reconfigurable pipeline and vice versa. the nodes are connectable together by an internode data router (hyperspace router) so as to form a hypercube configuration. The capability of the nodes to conditionally configure the pipeline at each tick of the clock, without requiring a pipeline flush, permits many powerful algorithms to be implemented directly.

  9. Capsule endoscopy—A mechatronics perspective

    NASA Astrophysics Data System (ADS)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  10. Experimental measurement on movement of spiral-type capsule endoscope

    PubMed Central

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability. PMID:26848279

  11. Experimental measurement on movement of spiral-type capsule endoscope.

    PubMed

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability.

  12. Fabrication of capsule assemblies, phase 3

    NASA Technical Reports Server (NTRS)

    Keeton, A. R.; Stemann, L. G.

    1973-01-01

    Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.

  13. Stopping mechanism for capsule endoscope using electrical stimulus.

    PubMed

    Woo, Sang Hyo; Kim, Tae Wan; Cho, Jin Ho

    2010-01-01

    An ingestible capsule, which has the ability to stop at certain locations in the small intestine, was designed and implemented to monitor intestinal diseases. The proposed capsule can contract the small intestine by using electrical stimuli; this contraction causes the capsule to stop when the maximum static frictional force (MSFF) is larger than the force of natural peristalsis. In vitro experiments were carried out to verify the feasibility of the capsule, and the results showed that the capsule was successfully stopped in the small intestine. Various electrodes and electrical stimulus parameters were determined on the basis of the MSFF. A moderate increment of the MSFF (12.7 +/- 4.6 gf at 5 V, 10 Hz, and 5 ms) and the maximum increment of the MSFF (56.5 +/- 9.77 gf at 20 V, 10 Hz, and 5 ms) were obtained, and it is sufficient force to stop the capsule.

  14. Identification of a functional capsule locus in Streptococcus mitis.

    PubMed

    Rukke, H V; Hegna, I K; Petersen, F C

    2012-04-01

    The polysaccharide capsule of Streptococcus pneumoniae is a hallmark for virulence in humans. In its close relative Streptococcus mitis, a common human commensal, analysis of the sequenced genomes of six strains revealed the presence of a putative capsule locus in four of them. We constructed an isogenic S. mitis mutant from the type strain that lacked the 19 open reading frames in the capsule locus (Δcps mutant), using a deletion strategy similar to previous capsule functional studies in S. pneumoniae. Transmission electron microscopy and atomic force microscopy revealed a capsule-like structure in the S. mitis type strain that was absent or reduced in the Δcps mutant. Since S. mitis are predominant oral colonizers of tooth surfaces, we addressed the relevance of the capsule locus for the S. mitis overall surface properties, autoaggregation and biofilm formation. The capsule deletion resulted in a mutant with approximately two-fold increase in hydrophobicity. Binding to the Stains-all cationic dye was reduced by 40%, suggesting a reduction in the overall negative surface charge of the mutant. The mutant exhibited also increased autoaggregation in coaggregation buffer, and up to six-fold increase in biofilm levels. The results suggested that the capsule locus is associated with production of a capsule-like structure in S. mitis and indicated that the S. mitis capsule-like structure may confer surface attributes similar to those associated with the capsule in S. pneumoniae. © 2011 John Wiley & Sons A/S.

  15. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  16. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  17. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  18. Production, deformation and mechanical investigation of magnetic alginate capsules

    NASA Astrophysics Data System (ADS)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  19. Pipeline repair development in support of the Oman to India gas pipeline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abadie, W.; Carlson, W.

    1995-12-01

    This paper provides a summary of development which has been conducted to date for the ultra deep, diverless pipeline repair system for the proposed Oman to India Gas Pipeline. The work has addressed critical development areas involving testing and/or prototype development of tools and procedures required to perform a diverless pipeline repair in water depths of up to 3,525 m.

  20. RANGE INCREASER FOR PNEUMATIC GAUGES

    DOEpatents

    Fowler, A.H.; Seaborn, G.B. Jr.

    1960-09-27

    An improved pneumatic gage is offered in which the linear range has been increased without excessive air consumption. This has been accomplished by providing an expansible antechamber connected to the nozzle of the gage so that the position of the nozzle with respect to the workpiece is varied automatically by variation in pressure within the antechamber. This arrangement ensures that the nozzle-to-workpiece clearance is maintained within certain limits, thus obtaining a linear relation of air flow to nozzle-to-workpiece clearance over a wider range.

  1. Pain and paraesthesia produced by silicone ring and pneumatic tourniquets.

    PubMed

    Mohan, A; Baskaradas, A; Solan, M; Magnussen, P

    2011-03-01

    Twenty volunteers were recruited to compare a novel, silicone ring tourniquet (the Hemaclear® tourniquet) with a pneumatic tourniquet. After application of the tourniquets, the pain and paraesthesia experienced by the participants was scored at 1 minute, 5 minutes, and 10 minutes. This was repeated with the tourniquets on the forearm. On the upper arm, the silicone ring tourniquet was associated with a significantly lower pain score than the pneumatic tourniquet. The incidence of paraesthesia was also lower with the silicone ring tourniquet. When applied to the forearm, there was no statistically significant difference in pain scores between the two types of tourniquets. However the incidence of paraesthesia was again lower with the silicone ring tourniquet.

  2. Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.

    PubMed

    Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi

    2014-08-07

    Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.

  3. Gettering capsule for removing oxygen from liquid lithium systems

    NASA Technical Reports Server (NTRS)

    Tower, L. K.; Breitwieser, R.

    1973-01-01

    Capsule consisting of tantalum shell lined with tantalum screen and partially filled with lithium and pieces of yttrium is immersed in hot lithium stream. Oxygen is removed from stream by being absorbed by gettering capsule. Oxygen passes through capsule wall and into lithium inside capsule where it reacts with yttrium to form Y2O3.

  4. 49 CFR 195.210 - Pipeline location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Pipeline location. 195.210 Section 195.210 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.210 Pipeline location. (a) Pipeline right-of-way must be selected to avoid, as...

  5. Innovation-Prototype. Making hydraulic and/or pneumatic plates using 3D printing technology

    NASA Astrophysics Data System (ADS)

    Alexa, V.; Rațiu, S. A.; Kiss, I.; Cioată, V. G.; Rackov, M.

    2018-01-01

    Start 3D printing allows hydraulic and/or pneumatic plates to be obtained from a single technological process without requiring further post-production operations. 3D printing with innovative materials in a rich colour range has several advantages such as: time-saving, cost is the same for any type of plate and its reported just to volume, fast and impossible realization of hydraulic and/or pneumatic links compared to traditional and high accuracy technologies.

  6. Motion of an elastic capsule in a square microfluidic channel.

    PubMed

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  7. Motion of an elastic capsule in a square microfluidic channel

    PubMed Central

    Kuriakose, S.; Dimitrakopoulos, P.

    2013-01-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e. small, moderate and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to, and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross-section in the upstream portion of large capsules is non-axisymmetric (i.e. square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a−2 for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux−u~h~a−2

  8. 3D Molding of Veneers by Mechanical and Pneumatic Methods

    PubMed Central

    Gaff, Milan; Gašparík, Miroslav

    2017-01-01

    This paper deals with the influence of selected methods (mechanical and pneumatic) as well as various factors (wood species, moisture content, veneer shape, punch diameter, laminating foil thickness, holding method, plasticizing) on 3D molding of veneers. 3D molding was evaluated on the basis of maximum deflection of birch and beech veneers. Cracks and warping edges were also evaluated in selected groups of mechanical molding. Mechanical methods tested veneers with various treatments (steaming, water and ammonia plasticizing and lamination). The pneumatic method was based on veneer shaping using air pressure. The results indicate that birch veneers are more suitable for 3D molding. The differences between the mechanical and pneumatic methods were not considerable. The most suitable method for mechanical 3D molding was the veneer lamination by polyethylene foils with thicknesses of 80 and 125 μm, inasmuch as these achieved better results than veneer plasticized by steam. The occurrence of cracks was more frequent in beech veneers, whereas, edge warping occurred at similar rates for both wood species and depends rather on holding method during 3D molding. Use of the ammonia solution is more suitable and there occurs no marked increase in moisture as happens when soaking in water. PMID:28772684

  9. Manually Operatable On-Chip Bistable Pneumatic Microstructures for Microfluidic Manipulations

    PubMed Central

    Chen, A.; Pan, T.

    2014-01-01

    Bistable microvalves are of particular interest because of their distinct nature requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries for microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integratability and small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPM) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly comprised of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), which users have direct control through finger pressing to switch between bistable vacuum state (VS) or atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that process blood samples to identify the distinct blood types (A/B/O) on chip. PMID:25007840

  10. Manually operatable on-chip bistable pneumatic microstructures for microfluidic manipulations.

    PubMed

    Chen, Arnold; Pan, Tingrui

    2014-09-07

    Bistable microvalves are of particular interest because of their distinct nature of requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries since microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integrability and a small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPMs) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly composed of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), of which users have direct control through finger pressing to switch either to the bistable vacuum state (VS) or the atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that processes blood samples to identify the distinct blood types (A/B/O) on-chip.

  11. 77 FR 2126 - Pipeline Safety: Implementation of the National Registry of Pipeline and Liquefied Natural Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-13

    ... Natural Gas Operators AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No...: ``Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting Requirements.'' The final rule...

  12. [The classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons].

    PubMed

    Kozachenko, I N

    2016-01-01

    The classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons remains to be developed. The objective of the present work was to elaborate the classification of the injuries caused by gunshots from the pneumatic weapons based on the analysis of 98 expert and acts of forensic medical expertises (surveys) of living subjects (n=76) and corpses (n=22) affected by gunshots from the pneumatic weapons. These materials were collected from the bureaus of forensic medical expertise in different regions of the Ukraine during the period from 2006 till 2015. In addition, scientific publications concerned with the problem of interest were used along with the relevant explanatory and terminological dictionaries. The terminology and the conceptual framework proposed by the author in the earlier papers provided a basis for the development of the first standard classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons categorized into 15 groups. It is believed that this classification will lay the foundation for the common approach of forensic medical experts to the examination and analysis of the data on the gunshots from the pneumatic weapons used to be found on the bodies of living subjects and the corpses. Moreover, it may be useful for the clinicians in their diagnostic and therapeutic practices and for the legal practitioners engaged in the quality assessment of the results of forensic medical expertises. It is recommended to present information about the gunshots from the pneumatic weapons in the accounting documents in a separate line.

  13. Light weight escape capsule for fighter aircraft

    NASA Technical Reports Server (NTRS)

    Robert, James A.

    1988-01-01

    Emergency crew escape capabilities have been less than adequate for fighter aircraft since before WW II. From the over-the-side bailout of those days through the current ejection seat with a rocket catapult, escaping from a disabled aircraft has been risky at best. Current efforts are underway toward developing a high-tech, smart ejection seat that will give fighter pilots more room to live in the sky, but an escape capsule is needed to meet current and future fighter envelopes. Escape capsules have a bad reputation due to past examples of high weight, poor performance and great complexity. However, the advantages available demand that a capsule be developed. This capsule concept will minimize the inherent disavantages and incorporate the benefits while integrating all aspects of crew station design. The resulting design is appropriate for a crew station of the year 2010 and includes improved combat acceleration protection, chemical or biological combat capability, improved aircraft to escape system interaction, and the highest level of escape performance achievable. The capsule is compact, which can allow a reduced aircraft size and weighs only 1200 lb. The escape system weight penalty is only 120 lb higher than that for the next ejection seat and the capsule has a corresponding increase in performance.

  14. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    NASA Astrophysics Data System (ADS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  15. Polar tent for reduced perturbation of NIF ignition capsules

    NASA Astrophysics Data System (ADS)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  16. 75 FR 72877 - Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... liquid pipelines, and liquefied natural gas (LNG) facilities. These revisions will enhance PHMSA's... of natural gas pipelines, hazardous liquid pipelines, and LNG facilities. Specifically, PHMSA... commodity transported, and type of commodity transported. 8. Modify hazardous liquid operator telephonic...

  17. 78 FR 42889 - Pipeline Safety: Reminder of Requirements for Utility LP-Gas and LPG Pipeline Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-18

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 [Docket No. PHMSA-2013-0097] Pipeline Safety: Reminder of Requirements for Utility LP-Gas and LPG Pipeline Systems AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION...

  18. Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System

    NASA Astrophysics Data System (ADS)

    Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren

    2017-11-01

    The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.

  19. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-09-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  20. Method and system for pipeline communication

    DOEpatents

    Richardson,; John, G [Idaho Falls, ID

    2008-01-29

    A pipeline communication system and method includes a pipeline having a surface extending along at least a portion of the length of the pipeline. A conductive bus is formed to and extends along a portion of the surface of the pipeline. The conductive bus includes a first conductive trace and a second conductive trace with the first and second conductive traces being adapted to conformally couple with a pipeline at the surface extending along at least a portion of the length of the pipeline. A transmitter for sending information along the conductive bus on the pipeline is coupled thereto and a receiver for receiving the information from the conductive bus on the pipeline is also couple to the conductive bus.

  1. General route for the assembly of functional inorganic capsules.

    PubMed

    Akartuna, Ilke; Tervoort, Elena; Studart, André R; Gauckler, Ludwig J

    2009-11-03

    Semipermeable, hollow capsules are attractive materials for the encapsulation and delivery of active agents in food processing, pharmaceutical and agricultural industries, and biomedicine. These capsules can be produced by forming a solid shell of close packed colloidal particles, typically polymeric particles, at the surface of emulsion droplets. However, current methods to prepare such capsules may involve multistep chemical procedures to tailor the surface chemistry of particles or are limited to particles that exhibit inherently the right hydrophobic-hydrophilic balance to adsorb around emulsion droplets. In this work, we describe a general and simple method to fabricate semipermeable, inorganic capsules from emulsion droplets stabilized by a wide variety of colloidal metal oxide particles. The assembly of particles at the oil-water interface is induced by the in situ hydrophobization of the particle surface through the adsorption of short amphiphilic molecules. The adsorption of particles at the interface leads to stable capsules comprising a single layer of particles in the outer shell. Such capsules can be used in the wet state or can be further processed into dry capsules. The permeability of the capsules can be modified by filling the interstices between the shell particles with polymeric or inorganic species. Functional capsules with biocompatible, bioresorbable, heat-resistant, chemical-resistant, and magnetic properties were prepared using alumina, silica, iron oxide, or tricalcium phosphate as particles in the shell.

  2. 21 CFR 520.260 - n-Butyl chloride capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules. (a)(1) Specifications. n-Butyl chloride capsules, veterinary contain 272 milligrams or 816 milligrams...

  3. IRRADIATION-CAPSULE STUDY OF URANIUM MONOCARBIDE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, R.B.; Stahl, D.; Stang, J.H.

    1960-03-01

    Small cylindrical specimens of enriched UC were irradiated to evaluate usefulness as a high-temperature fuel for stationary power reactors. Detailed thermal and nuclear analyses were made to arrive at an appropriate capsule design on the basis of target specimen center-line temperature ( approximately 1500 deg F), specimen surface temperature (1100 deg F), specimen composition (U--5 wt.% C), and acapsule o.d. of 1.125 in. Temperature data from thermocouples inside the capsule indicated that five of the six capsules irradiated operated at close to the design conditions. Irradiation periods for individual capsules were varied to give burnups ranging from 1,000 to 20,000more » Mwd/t of U. Preliminary evidence indicates that this range of burnups was achieved. By using temperature and heat-flux data from the actual irradiations to estimate effective in-pile specimen thermal conductivities, it was found that the conductivity did not appear to vary during the exposures. (auth)« less

  4. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    NASA Technical Reports Server (NTRS)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  5. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...

  6. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...

  7. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...

  8. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...

  9. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...

  10. [Improvement of Digital Capsule Endoscopy System and Image Interpolation].

    PubMed

    Zhao, Shaopeng; Yan, Guozheng; Liu, Gang; Kuang, Shuai

    2016-01-01

    Traditional capsule image collects and transmits analog image, with weak anti-interference ability, low frame rate, low resolution. This paper presents a new digital image capsule, which collects and transmits digital image, with frame rate up to 30 frames/sec and pixels resolution of 400 x 400. The image is compressed in the capsule, and is transmitted to the outside of the capsule for decompression and interpolation. A new type of interpolation algorithm is proposed, which is based on the relationship between the image planes, to obtain higher quality colour images. capsule endoscopy, digital image, SCCB protocol, image interpolation

  11. Ground reaction force comparison of bilateral symmetry with pneumatic resistance squat device and free weights - biomed 2009.

    PubMed

    Paulus, David C; Schilling, Brian K

    2009-01-01

    The unloading of spaceflight leads to bone and muscle atrophy, and a pneumatic resistance squat exercise countermeasure has the potential to provide optimized controllable resistance in a lightweight and compact configuration. However each end of the barbell in the proposed device is connected to a separate resistance cylinder which could lead to bilaterally asymmetric loading. Therefore, the purpose of the study is to compare the unilateral ground reaction forces (GRF) of the new squat device compared to free weights. Four previously trained men (mean +/- SD; age = 20+/-2 years, body mass = 99+/-18 kg) performed three sets of three repetitions of maximal exertion squat exercises with pneumatically controlled constant resistance and free weights each with a resistance level set to half of the body weight of each subject. Unilateral GRF data for each lifting modality at the negative to positive transition of the squat exercise was measured with a force plate under each foot. The pneumatic resistance GRF (N; mean +/- SD) was 749+/-114 on the left leg and 786+/-123 on the right leg and the free weight GRF was 786+/-114 left and 861+/-111 right resulting in a 5% difference between left and right GRF with pneumatics and 9% difference with free weights. The correlation coefficient between left and right GRF was 0.92 with pneumatics and 0.80 with free weights. Because the pneumatic device elicited more bilaterally symmetric GRF than traditional free weights, the separate resistance cylinders are an acceptable design configuration.

  12. Video capsule endoscopy: Perspectives of a revolutionary technique

    PubMed Central

    Bouchard, Simon; Ibrahim, Mostafa; Van Gossum, Andre

    2014-01-01

    Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding and is also indicated in some patients with Crohn’s disease, celiac disease, and polyposis syndrome. A video capsule has also been designed for visualizing the esophagus in order to detect Barrett’s esophagus or esophageal varices. Different capsules are now available and differ with regard to dimensions, image acquisition rate, battery life, field of view, and possible optical enhancements. More recently, the use of VCE has been extended to exploring the colon. Within the last 5 years, tremendous developments have been made toward increasing the capabilities of the colon capsule. Although colon capsule cannot be proposed as a first-line colorectal cancer screening procedure, colon capsule may be used in patients with incomplete colonoscopy or in patients who are unwilling to undergo colonoscopy. In the near future, new technological developments will improve the diagnostic yield of VCE and broaden its therapeutic capabilities. PMID:25516644

  13. 76 FR 75894 - Information Collection Activities: Pipelines and Pipeline Rights-of-Way; Submitted for Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-05

    ... pipelines `` * * * for the transportation of oil, natural gas, sulphur, or other minerals, or under such...) Submit repair report 3 1008(f) Submit report of pipeline failure analysis...... 30 1008(g) Submit plan of.... BSEE-2011-0002; OMB Control Number 1010-0050] Information Collection Activities: Pipelines and Pipeline...

  14. 77 FR 16052 - Information Collection Activities: Pipelines and Pipeline Rights-of-Way; Submitted for Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-19

    ... submerged lands of the OCS for pipelines ``* * * for the transportation of oil, natural gas, sulphur, or... ensure that the pipeline, as constructed, will provide for safe transportation of oil and gas and other...-0002; OMB Control Number 1014-0016] Information Collection Activities: Pipelines and Pipeline Rights...

  15. Hydrocarbons pipeline transportation risk assessment

    NASA Astrophysics Data System (ADS)

    Zanin, A. V.; Milke, A. A.; Kvasov, I. N.

    2018-04-01

    The pipeline transportation applying risks assessment issue in the arctic conditions is addressed in the paper. Pipeline quality characteristics in the given environment has been assessed. To achieve the stated objective, the pipelines mathematical model was designed and visualized by using the software product SOLIDWORKS. When developing the mathematical model the obtained results made possible to define the pipeline optimal characteristics for designing on the Arctic sea bottom. In the course of conducting the research the pipe avalanche collapse risks were examined, internal longitudinal and circular loads acting on the pipeline were analyzed, as well as the water impact hydrodynamic force was taken into consideration. The conducted calculation can contribute to the pipeline transport further development under the harsh climate conditions of the Russian Federation Arctic shelf territory.

  16. A multicenter, prospective, randomized comparison of a novel signal transmission capsule endoscope to an existing capsule endoscope.

    PubMed

    Choi, Eric H; Mergener, Klaus; Semrad, Carol; Fisher, Laurel; Cave, David R; Dodig, Milan; Burke, Carol; Leighton, Jonathan A; Kastenberg, David; Simpson, Peter; Sul, James; Bhattacharya, Kanishka; Charles, Roger; Gerson, Lauren; Weber, Luke; Eisen, Glenn; Reidel, Warren; Vargo, John J; Wakim-Fleming, Jamile; Lo, Simon K

    2013-08-01

    MiroCam, a capsule endoscope, uses a novel transmission technology, electric-field propagation, which uses the human body as a conduction medium for data transmission. To compare the ability of the MiroCam (MC) and PillCam (PC) to identify sources of obscure GI bleeding (OGIB). Prospective, multicenter, comparative study. Six academic hospitals. A total of 105 patients with OGIB. Patients ingested both the MC and PC capsules sequentially in a randomized fashion. Concordance of rates in identifying a source of OGIB, operational times, and rates of complete small-bowel examination. Data analysis resulted in 43 (48%) "abnormal" cases identifying a source of OGIB by either capsule. Twenty-four cases (55.8%) were positive by both capsules. There was negative agreement in 46 of 58 cases (79.3%). The κ index was 0.547 (χ(2) = 1.32; P = .36). In 12 cases, MC positively identified a source that was not seen on PC, whereas in 7 cases, PC positively identified a source that was not seen on MC. MC had a 5.6% higher rate of detecting small-bowel lesions (P = .54). MC captured images at 3 frames per second for 11.1 hours, and PC captured images at 2 frames per second for 7.8 hours (P < .0001). Complete small-bowel examination was achieved in 93.3% for MC and 84.3% for PC (P = .10). Readers were not blinded to the particular capsule they were reading. A positive diagnostic finding for OGIB was identified by either capsule in 48% of cases. The concordance rate between the 2 capsules was comparable to that of prior studies in identifying sources of small-bowel bleeding. The longer operational time of the MC may result in higher rates of complete small-bowel examination, which may, in turn, translate into a higher rate of detecting small-bowel lesions. ( NCT00878982.). Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. Pipeline surveillance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1976-03-01

    Each week, pilots of Michigan Wisconsin Pipe Line Co.'s aerial patrol fly over the entire 12,000 mi of the company's pipeline system to discover possible gas leaks and prevent accidental encroachment of pipeline right-of-way. (Leaks are uncommon, but as many as 10 potential trespassing incidents can occur along a route in a week.) Following the pipeline is facilitated by the warmth emitted by the line which affects the plant life directly above it. Gas leaks may be indicated by a patch of brown vegetation or by sediment brought to water surfaces by escaping gas bubbles. The 1- and 2-engine patrolmore » planes, which receive special permission from federal authorities to fly at low altitudes, undergo 100-h safety checks and frequent overhauls.« less

  18. Commanding Constellations (Pipeline Architecture)

    NASA Technical Reports Server (NTRS)

    Ray, Tim; Condron, Jeff

    2003-01-01

    Providing ground command software for constellations of spacecraft is a challenging problem. Reliable command delivery requires a feedback loop; for a constellation there will likely be an independent feedback loop for each constellation member. Each command must be sent via the proper Ground Station, which may change from one contact to the next (and may be different for different members). Dynamic configuration of the ground command software is usually required (e.g. directives to configure each member's feedback loop and assign the appropriate Ground Station). For testing purposes, there must be a way to insert command data at any level in the protocol stack. The Pipeline architecture described in this paper can support all these capabilities with a sequence of software modules (the pipeline), and a single self-identifying message format (for all types of command data and configuration directives). The Pipeline architecture is quite simple, yet it can solve some complex problems. The resulting solutions are conceptually simple, and therefore, reliable. They are also modular, and therefore, easy to distribute and extend. We first used the Pipeline architecture to design a CCSDS (Consultative Committee for Space Data Systems) Ground Telecommand system (to command one spacecraft at a time with a fixed Ground Station interface). This pipeline was later extended to include gateways to any of several Ground Stations. The resulting pipeline was then extended to handle a small constellation of spacecraft. The use of the Pipeline architecture allowed us to easily handle the increasing complexity. This paper will describe the Pipeline architecture, show how it was used to solve each of the above commanding situations, and how it can easily be extended to handle larger constellations.

  19. Analysis of Fission Products on the AGR-1 Capsule Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed tomore » determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.« less

  20. Capsule endoscope localization based on computer vision technique.

    PubMed

    Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H

    2009-01-01

    To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.

  1. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle.

    PubMed

    Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.

  2. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle

    PubMed Central

    Kim, Hyung Jin; Seo, Yeong Ho

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3–5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3–5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more. PMID:29216189

  3. Evacuation of coal from hoppers/silos with low pressure pneumatic blasting systems

    NASA Technical Reports Server (NTRS)

    Fischer, J. S.

    1977-01-01

    The need for an efficient, economical, effective and quiet device for moving coal and other difficult bulk solids was recognized. Thus came the advent of the low pressure pneumatic blasting system - a very efficient means of using a small amount of plant air (up to 125 PSI) to eliminate the most troublesome material hang-ups in storage containers. This simple device has one moving part and uses approximately 3% of the air consumed by a pneumatic vibrator on the same job. The principle of operation is very simple: air stored in the unit's reservoir is expelled directly into the material via a patented quick release valve. The number, size, and placement of the blaster units on the storage vessel is determined by a series of tests to ascertain flowability of the problem material. These tests in conjunction with the hopper or silo configuration determine specification of a low pressure pneumatic blasting system. This concept has often proven effective in solving flow problems when all other means have failed.

  4. Performance evaluation of wireless communications through capsule endoscope.

    PubMed

    Takizawa, Kenichi; Aoyagi, Takahiro; Hamaguchi, Kiyoshi; Kohno, Ryuji

    2009-01-01

    This paper presents a performance evaluation of wireless communications applicable into a capsule endoscope. A numerical model to describe the received signal strength (RSS) radiated from a capsule-sized signal generator is derived through measurements in which a liquid phantom that has equivalent electrical constants is used. By introducing this model and taking into account the characteristics of its direction pattern of the capsule and propagation distance between the implanted capsule and on-body antenna, a cumulative distribution function (CDF) of the received SNR is evaluated. Then, simulation results related to the error ratio in the wireless channel are obtained. These results show that the frequencies of 611 MHz or lesser would be useful for the capsule endoscope applications from the view point of error rate performance. Further, we show that the use of antenna diversity brings additional gain to this application.

  5. Electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and graphical user interface platform for aviation industries training purposes

    NASA Astrophysics Data System (ADS)

    Burhan, I.; Azman, A. A.; Othman, R.

    2016-10-01

    An electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and Visual Basic (VB) platform is fabricated as a supporting tool to existing teaching and learning process, and to achieve the objectives and learning outcomes towards enhancing the student's knowledge and hands-on skill, especially in electro pneumatic devices. The existing learning process for electro pneumatic courses conducted in the classroom does not emphasize on simulation and complex practical aspects. VB is used as the platform for graphical user interface (GUI) while PIC as the interface circuit between the GUI and hardware of electro pneumatic apparatus. Fabrication of electro pneumatic trainer interfacing between PIC and VB has been designed and improved by involving multiple types of electro pneumatic apparatus such as linear drive, air motor, semi rotary motor, double acting cylinder and single acting cylinder. Newly fabricated electro pneumatic trainer microcontroller interface can be programmed and re-programmed for numerous combination of tasks. Based on the survey to 175 student participants, 97% of the respondents agreed that the newly fabricated trainer is user friendly, safe and attractive, and 96.8% of the respondents strongly agreed that there is improvement in knowledge development and also hands-on skill in their learning process. Furthermore, the Lab Practical Evaluation record has indicated that the respondents have improved their academic performance (hands-on skills) by an average of 23.5%.

  6. Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.

    PubMed

    Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar

    2013-08-27

    Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to

  7. A wireless narrowband imaging chip for capsule endoscope.

    PubMed

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.

  8. Positron radiography of ignition-relevant ICF capsules

    DOE PAGES

    Williams, G. J.; Chen, Hui; Field, J. E.; ...

    2017-12-11

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less

  9. Positron radiography of ignition-relevant ICF capsules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, G. J.; Chen, Hui; Field, J. E.

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less

  10. Positron radiography of ignition-relevant ICF capsules

    NASA Astrophysics Data System (ADS)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  11. Main Pipelines Corrosion Monitoring Device

    NASA Astrophysics Data System (ADS)

    Anatoliy, Bazhenov; Galina, Bondareva; Natalia, Grivennaya; Sergey, Malygin; Mikhail, Goryainov

    2017-01-01

    The aim of the article is to substantiate the technical solution for the problem of monitoring corrosion changes in oil and gas pipelines with use (using) of an electromagnetic NDT method. Pipeline wall thinning under operating conditions can lead to perforations and leakage of the product to be transported outside the pipeline. In most cases there is danger for human life and environment. Monitoring of corrosion changes in pipeline inner wall under operating conditions is complicated because pipelines are mainly made of structural steels with conductive and magnetic properties that complicate test signal passage through the entire thickness of the object under study. The technical solution of this problem lies in monitoring of the internal corrosion changes in pipes under operating conditions in order to increase safety of pipelines by automated prediction of achieving the threshold pre-crash values due to corrosion.

  12. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where...

  13. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where...

  14. Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for calculus in bladder diverticula

    PubMed Central

    GU, SI-PING; YOU, ZHI-YUAN; HUANG, YUNTENG; LU, YI-JIN; HE, CAOHUI; CAI, XIAO-DONG; ZHOU, XIAO-MING

    2013-01-01

    The aim of this study was to investigate the effectiveness of minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for treating calculus in bladder diverticula. Percutaneous cystostomy with ureteroscopic pneumatic lithotripsy was performed on six elderly male patients with calculi in bladder diverticula, who could not be treated with transurethral ureteroscopic lithotripsy. The stones were successfully removed from all patients, with no complications such as bladder perforation, rupture, urethritis or cystitis. The surgery time was 15–60 min, with an average time of 32 min. Postoperative ultrasound or X-ray examination showed no stone residues and the bladder stoma healed well. No recurrent stones were detected in the follow-up of 3–24 months (average, 16 months). Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy is a safe, efficient and easy treatment for calculus in bladder diverticula. This method provides a new clinical approach for lithotripsy and we suggest that it is worthy of wider use. PMID:23837044

  15. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed Central

    Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.

    2016-01-01

    Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719

  16. The X-shooter pipeline

    NASA Astrophysics Data System (ADS)

    Goldoni, P.

    2011-03-01

    The X-shooter data reduction pipeline is an integral part of the X-shooter project, it allows the production of reduced data in physical quantities from the raw data produced by the instrument. The pipeline is based on the data reduction library developed by the X-shooter consortium with contributions from France, The Netherlands and ESO and it uses the Common Pipeline Library (CPL) developed at ESO. The pipeline has been developed for two main functions. The first function is to monitor the operation of the instrument through the reduction of the acquired data, both at Paranal, for a quick-look control, and in Garching, for a more thorough evaluation. The second function is to allow an optimized data reduction for a scientific user. In the following I will first outline the main steps of data reduction with the pipeline then I will briefly show two examples of optimization of the results for science reduction.

  17. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric plethysmographs. 870.2780 Section 870.2780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices...

  18. A Rare Cause of Headache: Pneumatized Nasal Septum Osteoma.

    PubMed

    Erdoğan, Osman; Ismi, Onur; Tezer, Mesut Sabri

    2017-11-01

    Paranasal sinus osteomas are among the rare causes of headache and they are most commonly seen in the frontal and ethmoid sinuses. In this report, we presented the first case of pneumatized nasal septum osteoma causing headache, successfully treated with endoscopic transnasal approach.

  19. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric plethysmographs. 870.2780 Section 870.2780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices...

  20. Capsule-odometer: a concept to improve accurate lesion localisation.

    PubMed

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  1. Wireless communication link for capsule endoscope at 600 MHz.

    PubMed

    Khaleghi, A; Balasingham, I

    2015-01-01

    Simulation of a wireless communication link for a capsule endoscopy is presented for monitoring of small intestine in humans. The realized communication link includes the transmitting capsule antenna, the outside body receiving antenna and the model of the human body. The capsule antenna is designed for operating at the frequency band of 600 MHz with an impedance bandwidth of 10 MHz and omnidirectional radiation pattern. The quality of the communication link is improved by using directive antenna outside body inside matching layer for electromagnetic wave tuning to the body. The outside body antenna has circular polarization that guaranteeing the communication link for different orientations of the capsule inside intestine. It is shown that the path loss for the capsule in 60 mm from the abdomen surface varies between 37-47 dB in relation to the antenna orientation. This link can establish high data rate wireless communications for capsule endoscopy.

  2. Primate lens capsule elasticity assessed using Atomic Force Microscopy

    PubMed Central

    Ziebarth, Noël M.; Arrieta, Esdras; Feuer, William J.; Moy, Vincent T.; Manns, Fabrice; Parel, Jean-Marie

    2011-01-01

    The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9–8.0 years), 8 hamadryas baboon (2.8–10.1 years), and 18 human lenses (33–79 years). Anterior capsule specimens were obtained by performing a 5mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for five minutes, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young’s modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young’s modulus of elasticity was 20.1–131kPa for the human lens capsule, 9.19–117kPa for the cynomolgus lens capsule, and 13.1–62.4kPa for the baboon lens capsule. Young’s modulus increased significantly with age in humans (p=0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness. PMID:21420953

  3. Closeup View - Sigma "7" Capsule - Recovery Ship

    NASA Image and Video Library

    1962-10-03

    S62-06175 (3 Oct. 1962) --- Closeup view of the Mercury-Atlas 8 (MA-8) Sigma 7 capsule being lowered to recovery ship's deck. Navy personnel remove the floatation device before opening the capsule. Photo credit: NASA

  4. About U.S. Natural Gas Pipelines

    EIA Publications

    2007-01-01

    This information product provides the interested reader with a broad and non-technical overview of how the U.S. natural gas pipeline network operates, along with some insights into the many individual pipeline systems that make up the network. While the focus of the presentation is the transportation of natural gas over the interstate and intrastate pipeline systems, information on subjects related to pipeline development, such as system design and pipeline expansion, are also included.

  5. Development of X-Y servo pneumatic-piezoelectric hybrid actuators for position control with high response, large stroke and nanometer accuracy.

    PubMed

    Chiang, Mao-Hsiung

    2010-01-01

    This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally.

  6. Development of X-Y Servo Pneumatic-Piezoelectric Hybrid Actuators for Position Control with High Response, Large Stroke and Nanometer Accuracy

    PubMed Central

    Chiang, Mao-Hsiung

    2010-01-01

    This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally. PMID:22319266

  7. Capsule endoscopy: Current practice and future directions

    PubMed Central

    Hale, Melissa F; Sidhu, Reena; McAlindon, Mark E

    2014-01-01

    Capsule endoscopy (CE) has transformed investigation of the small bowel providing a non-invasive, well tolerated means of accurately visualising the distal duodenum, jejunum and ileum. Since the introduction of small bowel CE thirteen years ago a high volume of literature on indications, diagnostic yields and safety profile has been presented. Inclusion in national and international guidelines has placed small bowel capsule endoscopy at the forefront of investigation into suspected diseases of the small bowel. Most commonly, small bowel CE is used in patients with suspected bleeding or to identify evidence of active Crohn’s disease (CD) (in patients with or without a prior history of CD). Typically, CE is undertaken after upper and lower gastrointestinal flexible endoscopy has failed to identify a diagnosis. Small bowel radiology or a patency capsule test should be considered prior to CE in those at high risk of strictures (such as patients known to have CD or presenting with obstructive symptoms) to reduce the risk of capsule retention. CE also has a role in patients with coeliac disease, suspected small bowel tumours and other small bowel disorders. Since the advent of small bowel CE, dedicated oesophageal and colon capsule endoscopes have expanded the fields of application to include the investigation of upper and lower gastrointestinal disorders. Oesophageal CE may be used to diagnose oesophagitis, Barrett’s oesophagus and varices but reliability in identifying gastroduodenal pathology is unknown and it does not have biopsy capability. Colon CE provides an alternative to conventional colonoscopy for symptomatic patients, while a possible role in colorectal cancer screening is a fascinating prospect. Current research is already addressing the possibility of controlling capsule movement and developing capsules which allow tissue sampling and the administration of therapy. PMID:24976712

  8. Inadvertent trypan blue posterior capsule staining during cataract surgery.

    PubMed

    Burkholder, Bryn M; Srikumaran, Divya; Nanji, Afshan; Lee, Bryan; Weinberg, Robert S

    2013-04-01

    To report 5 cases of inadvertent posterior capsule staining with trypan blue during phacoemulsification. Retrospective, observational case series. Five cases of posterior capsule staining with trypan blue were identified from cataract surgeries performed at an academic institution. All 5 eyes underwent phacoemulsification with use of iris retractors. The surgical videos from each case were reviewed to better understand the mechanisms and risk factors for posterior capsule staining with trypan blue and techniques to avoid this complication. No eyes had clinical evidence of zonular pathology during their preoperative examination. Only 1 patient reported a possible childhood history of trauma to both eyes. One eye had uveitis, requiring posterior synechialysis. All 5 cases involved the use of iris retractors. No other intraoperative complications occurred, and the intraocular lens was successfully placed in the capsular bag in all cases. All eyes had resolution of posterior capsule staining by postoperative day 8. Inadvertent posterior capsule staining with trypan blue can occur in eyes that appear structurally normal. The use of iris retractors may facilitate posterior capsule staining by allowing the posterior flow of trypan blue under the iris and through the zonules to the posterior capsule. Surgeons should consider techniques to minimize the risk of posterior capsule staining, particularly in cases involving the use of iris retractors. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Tests of cryogenic pigs for use in liquefied gas pipelines

    NASA Astrophysics Data System (ADS)

    Hipple, D. L.; Oneal, W. C.

    1982-09-01

    Pipeline pigs are a key element in the design of a proposed spill test facility whose purpose is to evaluate the hazards of large spills of liquefied gaseous fuels (LGFs). A long pipe runs from the LGF storage tanks to the spill point; to produce a rapid spill, the pipe is filled with LGF and a pig will be pneumatically driven through the pipe to force out the LGF quickly and cleanly. Several pig designs were tested in a 6 inch diameter, 420 foot long pipe to evaluate their performance at liquid-nitrogen temperature and compare it with their performance at ambient temperature. For each test, the pig was placed in one end of the pipe and either water or liquid nitrogen was put into the pipe in front of the pig. Then pressurized drive gas, either nitrogen or helium, was admitted to the pipe behind the pig to push the pig and the fluid ahead of it out the exit nozzle. For some tests, the drive gas supply was shut off when the pig was part way through the pipe as a method of velocity control; in these cases, the pressurized gas trapped behind the pig continued to expand until it pushed the pig the remaining distance out of the pipe.

  10. Aspiration of capsule endoscope and successful bronchoscopic extraction.

    PubMed

    Girdhar, Ankur; Usman, Faisal; Bajwa, Abubakr

    2012-10-01

    Capsule endoscopy is a novel tool for the diagnosis of small intestinal disorders. Recently, a new complication of the procedure in the form of the capsule's aspiration into the lungs has been reported. The aspiration of capsule endoscope can lead to a variety of complications including respiratory failure. A low threshold to suspect this complication and urgent bronchoscopic extraction in appropriate patients can prevent serious sequelae.

  11. Alaska oil pipeline in retrospect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, D.R.

    Caribou have not adjusted as well as moose to the presence of the trans-Alaska pipeline. Research has shown that caribou have altered their movements and patterns and range use in relation to the pipeline corridor. Cows with calves show pronounced avoidance of the pipeline, road, and oil field. Traffic and human activity appear more directly responsible for avoidance behavior than does that physical presence of the pipeline, road, and facilities. Animals along the haul road are especially vulnerable to poaching because of the open terrain and the fact that many become tame during the peak of construction activity. Poaching, especiallymore » of furbearers, has increased as pipeline-related traffic has decreased.« less

  12. Bronchial Aspiration of Capsule Endoscope.

    PubMed

    Buscot, Matthieu; Leroy, Sylvie; Pradelli, Johanna; Chaabane, Nouha; Hebuterne, Xavier; Marquette, Charles-Hugo; Filippi, Jerôme

    2017-01-01

    Capsule endoscope aspiration is an increasingly reported complication, potentially responsible for respiratory distress and asphyxia. This adverse event is primarily managed by rigid bronchoscopy when spontaneous expulsion does not occur. This complication is all the more detrimental to patients as it can delay or jeopardize further digestive exploration. We report direct repositioning of the capsule in the stomach at the same time as bronchoscopy, thus making second-line gastrointestinal endoscopy needless. © 2017 S. Karger AG, Basel.

  13. The ALMA Science Pipeline: Current Status

    NASA Astrophysics Data System (ADS)

    Humphreys, Elizabeth; Miura, Rie; Brogan, Crystal L.; Hibbard, John; Hunter, Todd R.; Indebetouw, Remy

    2016-09-01

    The ALMA Science Pipeline is being developed for the automated calibration and imaging of ALMA interferometric and single-dish data. The calibration Pipeline for interferometric data was accepted for use by ALMA Science Operations in 2014, and for single-dish data end-to-end processing in 2015. However, work is ongoing to expand the use cases for which the Pipeline can be used e.g. for higher frequency and lower signal-to-noise datasets, and for new observing modes. A current focus includes the commissioning of science target imaging for interferometric data. For the Single Dish Pipeline, the line finding algorithm used in baseline subtraction and baseline flagging heuristics have been greately improved since the prototype used for data from the previous cycle. These algorithms, unique to the Pipeline, produce better results than standard manual processing in many cases. In this poster, we report on the current status of the Pipeline capabilities, present initial results from the Imaging Pipeline, and the smart line finding and flagging algorithm used in the Single Dish Pipeline. The Pipeline is released as part of CASA (the Common Astronomy Software Applications package).

  14. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... http://dms.dot.gov . General information about the PHMSA Office of Pipeline Safety (OPS) can be... of leak detection by tracking product movement is essential to an understanding of line balance... pipelines, the line balance technique for leak detection can often be performed with manual calculations...

  15. Therapeutic Application of Phage Capsule Depolymerases against K1, K5, and K30 Capsulated E. coli in Mice.

    PubMed

    Lin, Han; Paff, Matthew L; Molineux, Ian J; Bull, James J

    2017-01-01

    Capsule depolymerase enzymes offer a promising class of new antibiotics. In vivo studies are encouraging but it is unclear how well this type of phage product will generalize in therapeutics, or whether different depolymerases against the same capsule function similarly. Here, in vivo efficacy was tested using cloned bacteriophage depolymerases against Escherichia coli strains with three different capsule types: K1, K5, and K30. When treating infections with the cognate capsule type in a mouse thigh model, the previously studied K1E depolymerase rescued poorly, whereas K1F, K1H, K5, and K30 depolymerases rescued well. K30 gp41 was identified as the catalytically active protein. In contrast to the in vivo studies, K1E enzyme actively degraded K1 capsule polysaccharide in vitro and sensitized K1 bacteria to serum killing. The only in vitro correlate of poor K1E performance in vivo was that the purified enzyme did not form the expected trimer. K1E appeared as an 18-mer which might limit its in vivo distribution. Overall, depolymerases were easily identified, cloned from phage genomes, and as purified proteins they proved generally effective.

  16. Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields

    NASA Astrophysics Data System (ADS)

    Wischnewski, Christian; Kierfeld, Jan

    2018-04-01

    We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.

  17. 77 FR 6857 - Pipeline Safety: Notice of Public Meetings on Improving Pipeline Leak Detection System...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-09

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID... installed to lessen the volume of natural gas and hazardous liquid released during catastrophic pipeline... p.m. Panel 3: Considerations for Natural Gas Pipeline Leak Detection Systems 3:30 p.m. Break 3:45 p...

  18. Pneumatic preloaded scanning science launch latch system

    NASA Technical Reports Server (NTRS)

    Kievit, J. C.

    1979-01-01

    A relatively simple system using a preloaded pneumatic piston latch with a pyrotechnic valve release was developed. The system was the only candidate that met all the imposed requirements utilizing reliable state-of-art components. The development of the latch system from its first use on Mariner '69 Mars Flyby Spacecraft through its most recent use on the Voyager Spacecraft that will fly to Jupiter and Saturn is reviewed.

  19. Development of three-layered rumen escapable capsules for cattle

    PubMed Central

    SEYAMA, Tomohiro; HIRAYASU, Hirofumi; YAMAWAKI, Kenji; ADACHI, Takuhiko; SUGIMOTO, Takayuki; KASAI, Koji

    2016-01-01

    A new rumen escapable tool is presented for cattle in prospect of developing medical treatment or supplementing trace elements for disease prevention. This tool consists of a three-layered capsule that dissolves in the lower digestive tract, but not in the rumen. The capsule was manufactured by capsule-forming techniques through the use of liquid surface tension. This method does not involve high-temperature treatment, so the capsule can contain not only lipophilic substances but also hydrophilic or heat-sensitive substances. Furthermore, the capsule has a specific gravity of 1.3 and diameter of 6.0 mm, which were previously shown to be appropriate to avoid rumination. The objective of this study was to confirm the effectiveness of the capsule pertinent to rumen escaping. In order to validate rumen escape, capsules containing 30 g of water-soluble vitamin (thiamine hydrochloride) per head were administered to four lactating cows assigned in a crossover trial. In the group administered encapsulated thiamine hydrochloride, blood thiamine levels increased from 12.4 ± 1.03 ng/ml before administration to 54.8 ± 2.21 ng/ml at 6 hr following administration, whereas the level remained at 13.3 ± 2.05 ng/ml in the control group administered via aqueous solution. This indicates that the three-layered capsules passed through the rumen and dissolved in the lower digestive tract, thus functioning as a rumen escapable tool. PMID:27546371

  20. Safety and efficacy of transurethral pneumatic lithotripsy for bladder calculi in children.

    PubMed

    Khosa, Ali Sher; Hussain, Muhammad; Hussain, Manzoor

    2012-12-01

    To determine the safety and efficacy of transurethral pneumatic lithotripsy for bladder calculi in children. The study included 100 children up to 15 years of age undergoing pneumatic cystolithoclast for bladder stones. The descriptive study was conducted from September 2006 to February 2007 at the Sindh Institute of Urology and Transplantation, Karachi. The inclusion criteria was children up to 15 years of age with a bladder stone of up to 3cm, pre-operative negative urine culture, no coagulopathy and fit for general anaesthesia. An X-ray and ultrasound of Kidney and Urinary Bladder (KUB) was mandatory. The procedure was done under general anaesthesia with a single dose of pre-operative antibiotic. A mini-scope of 4FR or a semi-rigid ureteroscope of 7/8.5 FR with pneumatic wolf lithoclast was used for the fragmentation of stones. Duration of procedure, any per-operative and post-operative complications and the duration of hospital stay were recorded. Post-operatively, the patient underwent ultrasound Kidney and Urinary Bladder at the first follow-up to assess stone clearance after one week. Mean patients age was 4.95 +/- 3.3 years. The male-to-female ratio was 11.5: 1 The mean hospital stay was 9.2 +/- 2.5 hours. The mean operating time was 25 (10 -65) minutes. Ten (10%) patients developed minor complications out of which 5 (5%) developed haematuria and 4 (4%) developed difficulty in passing urine. One (1%) of the patients developed post-operative retention of urine. All the patients were stone-free after the procedure. The transurethral pneumatic lithoclast is very effective and safe in children with bladder stones up to 3cm.

  1. Unusual Internal Astigmatism Due to Severe Capsule Contraction Syndrome.

    PubMed

    Zéboulon, Pierre; Gatinel, Damien

    2018-01-01

    To describe a case of severe capsule contraction syndrome causing significant astigmatism due to intraocular lens (IOL) folding. Case report. Capsule fibrosis and contraction resulted in bending of the hydrophilic IOL along its long axis. Anterior Nd:YAG capsulotomy resolved the situation and restored the patient's visual acuity. Hydrophilic IOLs are more susceptible to capsule contraction due to the increased flexibility of highly hydrated materials. They should be avoided in patients at risk of capsule contraction to prevent ocular complications. [J Refract Surg. 2018;34(1):65-67.]. Copyright 2018, SLACK Incorporated.

  2. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  3. Development of a compact portable driver for a pneumatic ventricular assist device.

    PubMed

    Nishinaka, Tomohiro; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Ohnishi, Hiroyuki; Homma, Akihiko; Shioya, Kyoko; Mizuno, Toshihide; Tsukiya, Tomonori; Mushika, Sadahiko; Hashiguchi, Yasuhiro; Suzuki, Akira; Kitamura, Soichiro

    2007-01-01

    The Toyobo-National Cardiovascular Center pneumatic ventricular assist device (Toyobo-NCVC VAD) is widely used in Japan; however, the current pneumatic drivers have some drawbacks, including their large size, heavy weight, and high power consumption. These issues cause difficulty with mobility and contribute to an unsatisfactory quality of life for patients. Because it is urgently necessary to improve patients' safety and quality of life, we have developed a compact, low-noise, portable VAD driver by utilizing an electrohydraulic actuator consisting of a brushless DC motor and a regenerative pump. This unit can be actuated for as long as 2 h with two rechargeable lightweight batteries as well as with external AC power. It is compact in size (33 x 25 x 43 cm) and light in weight (13 kg), and the unit is carried on a mobile wheeled cart. In vitro testing with a Toyobo-NCVC VAD demonstrated a sufficient pumping capacity of up to 8 l/min. We conclude that this newly-developed compact portable driver can provide a better quality of life and improved safety for patients using protracted pneumatic VAD support.

  4. Albumin/asparaginase capsules prepared by ultrasound to retain ammonia.

    PubMed

    Tinoco, Ana; Ribeiro, Artur; Oliveira, César; Parpot, Pier; Gomes, Andreia; Cavaco-Paulo, Artur

    2016-11-01

    Asparaginase reduces the levels of asparagine in blood, which is an essential amino acid for the proliferation of lymphoblastic malign cells. Asparaginase converts asparagine into aspartic acid and ammonia. The accumulation of ammonia in the bloodstream leads to hyperammonemia, described as one of the most significant side effects of asparaginase therapy. Therefore, there is a need for asparaginase formulations with the potential to reduce hyperammonemia. We incorporated 2 % of therapeutic enzyme in albumin-based capsules. The presence of asparaginase in the interface of bovine serum albumin (BSA) capsules showed the ability to hydrolyze the asparagine and retain the forming ammonia at the surface of the capsules. The incorporation of Poloxamer 407 in the capsule formulation further increased the ratio aspartic acid/ammonia from 1.92 to 2.46 (and 1.10 from the free enzyme), decreasing the levels of free ammonia. This capacity to retain ammonia can be due to electrostatic interactions and retention of ammonia at the surface of the capsules. The developed BSA/asparaginase capsules did not cause significant cytotoxic effect on mouse leukemic macrophage cell line RAW 264.7. The new BSA/asparaginase capsules could potentially be used in the treatment of acute lymphoblastic leukemia preventing hyperammonemia associated with acute lymphoblastic leukemia (ALL) treatment with asparaginase.

  5. Closed Loop Control of a Tethered Magnetic Capsule Endoscope

    PubMed Central

    Taddese, Addisu Z.; Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro

    2017-01-01

    Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy. PMID:28286886

  6. Closed Loop Control of a Tethered Magnetic Capsule Endoscope.

    PubMed

    Taddese, Addisu Z; Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2016-06-01

    Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy.

  7. Soft, Rotating Pneumatic Actuator.

    PubMed

    Ainla, Alar; Verma, Mohit S; Yang, Dian; Whitesides, George M

    2017-09-01

    This article describes a soft pneumatic actuator that generates cyclical motion. The actuator consists of several (three, four, or five) chambers (arranged around the circumference of a circle surrounding a central rod) that can be actuated independently using negative pressure (or partial vacuum). Sequential actuation of the four-chamber device using reduced pressure moves the central rod cyclically in an approximately square path. We characterize the trajectory of the actuator and the force exerted by it, as we vary the material used for fabrication, the number of chambers, and the size of the actuator. We demonstrate two applications of this actuator: to deliver fluid while stirring (by replacing the central rod with a needle) and for locomotion that mimics a reptilian gait (by combining four actuators together).

  8. Analysing intracellular deformation of polymer capsules using structured illumination microscopy

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Cui, Jiwei; Sun, Huanli; Müllner, Markus; Yan, Yan; Noi, Ka Fung; Ping, Yuan; Caruso, Frank

    2016-06-01

    Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties.Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces

  9. The capsule of the fungal pathogen Cryptococcus neoformans

    PubMed Central

    Zaragoza, Oscar; Rodrigues, Marcio L.; De Jesus, Magdia; Frases, Susana; Dadachova, Ekaterina; Casadevall, Arturo

    2009-01-01

    The capsule of the fungal pathogen Cryptococcus neoformans has been studied extensively in recent decades, and a large body of information is now available to the scientific community. Well-known aspects of the capsule include its structure, antigenic properties and its function as a virulence factor. The capsule is composed primarily of two polysaccharides, glucuronoxylomannan (GXM) and galactoxylomannan (GalXM), in addition to a smaller proportion of mannoproteins (MP). Most of the studies on the composition of the capsule have focused on GXM, which comprises more than 90% of the capsule's polysaccharide mass. It is GalXM, however, that is of particular scientific interest because of its immunological properties. The molecular structure of these polysaccharides is very complex and has not yet been fully elucidated. Both GXM and GalXM are high molecular mass polymers with the mass of GXM equaling roughly 10 times that of GalXM. Recent findings suggest, however, that the actual Mw might be different to what it has traditionally been thought to be. In addition to their structural roles in the polysaccharide capsule, these molecules have been associated with many deleterious effects on the immune response. Capsular components are therefore considered key virulence determinants in Cryptococcus neoformans, which has motivated their use in vaccines and made them targets for monoclonal antibody treatments. In this review we will provide an update on the current knowledge of the C. neoformans capsule, covering aspects related to its structure, synthesis, and particularly, its role as a virulence factor. PMID:19426855

  10. Tag gas capsule with magnetic piercing device

    DOEpatents

    Nelson, Ira V.

    1976-06-22

    An apparatus for introducing a tag (i.e., identifying) gas into a tubular nuclear fuel element. A sealed capsule containing the tag gas is placed in the plenum in the fuel tube between the fuel and the end cap. A ferromagnetic punch having a penetrating point is slidably mounted in the plenum. By external electro-magnets, the punch may be caused to penetrate a thin rupturable end wall of the capsule and release the tag gas into the fuel element. Preferably the punch is slidably mounted within the capsule, which is in turn loaded as a sealed unit into the fuel element.

  11. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  12. 23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  13. Alternative method for enteric coating of HPMC capsules resulting in ready-to-use enteric-coated capsules.

    PubMed

    Huyghebaert, Nathalie; Vermeire, An; Remon, Jean Paul

    2004-04-01

    The aim of this study was to develop an alternative method for enteric coating of HPMC capsules that avoids the sealing step before coating, resulting in ready-to-use enteric-coated capsules for the use in retail or hospital pharmacy or R&D sections of pharmaceutical industry and for the production of enteric-coated heat and moisture sensitive biomaterials. HPMC caps and bodies 00 (Vcaps, Capsugel) were coated separately in a fluid bed apparatus prior to filling (GPCG-1, Glatt) with Eudragit L30D-55 or Eudragit FS 30 D (Röhm), Aqoat AS-HF (Shin-Etsu) and Sureteric (Colorcon), using an optimised coating process. The coated bodies were filled and closed with the coated caps without encountering problems of coating damage. The release in 0.1N HCl after 2h from capsules coated with Eudragit L30D-55, Eudragit FS 30 D, Aqoat AS-HF and Sureteric was 0.6+/-.03, 0.6+/-0.3, 1.2+/-0.2 and 7.3+/-1.9%, respectively. The alternative method was reproducible and offered a way to overcome the time-consuming and expensive sealing step required using the conventional coating procedure. The obtained enteric-coated HPMC capsules can be stored (un)-filled for at least 6 months without loosing enteric properties.

  14. MACULAR HOLE FORMATION FOLLOWED BY SPONTANEOUS CLOSURE AFTER PNEUMATIC RETINOPEXY IN A PATIENT WITH DIABETIC MACULAR EDEMA.

    PubMed

    Cohen, Michael N; Baumal, Caroline R

    2018-05-10

    To report early formation and spontaneous closure of a full-thickness macular hole that developed after successful pneumatic retinopexy in a patient who had been undergoing treatment for diabetic macular edema. Case report of a 68-year-old man with bilateral nonproliferative diabetic retinopathy who was currently undergoing anti-vascular endothelial growth factor treatment for bilateral diabetic macular edema. On presentation, visual acuity was 20/200 in the left eye, and examination revealed a bullous, macula-off retinal detachment with a single horseshoe tear at 12 o'clock in the left eye. Pneumatic retinopexy was performed followed by laser augmentation 3 days later. Three weeks postoperatively, he returned with visual acuity of 20/50 and a full-thickness macular hole in the left eye. Although he elected for initial observation, he returned 2 weeks later with visual acuity of 20/50 in both eyes and a retinal detachment with a single break at 10 o'clock in the right eye. The macular hole in the left eye had spontaneously resolved. Pneumatic retinopexy was performed to the right eye. Over 1 year after bilateral pneumatic retinopexy, his retina remains without recurrence of a macular hole in the left eye. In the early postoperative period after pneumatic retinopexy to repair a retinal detachment, a macular hole can form and spontaneously close.

  15. Capsule Shimming Developments for National Ignition Facility (NIF) Hohlraum Asymmetry Experiments

    DOE PAGES

    Rice, Neal G.; Vu, M.; Kong, C.; ...

    2017-12-20

    Capsule drive in National Ignition Facility (NIF) indirect drive implosions is generated by x-ray illumination from cylindrical hohlraums. The cylindrical hohlraum geometry is axially symmetric but not spherically symmetric causing capsule-fuel drive asymmetries. We hypothesize that fabricating capsules asymmetric in wall thickness (shimmed) may compensate for drive asymmetries and improve implosion symmetry. Simulations suggest that for high compression implosions Legendre mode P 4 hohlraum flux asymmetries are the most detrimental to implosion performance. General Atomics has developed a diamond turning method to form a GDP capsule outer surface to a Legendre mode P 4 profile. The P 4 shape requiresmore » full capsule surface coverage. Thus, in order to avoid tool-lathe interference flipping the capsule part way through the machining process is required. This flipping process risks misalignment of the capsule causing a vertical step feature on the capsule surface. Recent trials have proven this step feature height can be minimized to ~0.25 µm.« less

  16. Scaling effects in spiral capsule robots.

    PubMed

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  17. Mechanical characterization of capsule properties using abrupt-step channels

    NASA Astrophysics Data System (ADS)

    Salsac, Anne-Virginie; Le Goff, Anne; Kaoui, Badr; Barthè-Biesel, Dominique; Biomechanics; Bioengineering Lab Team

    2017-11-01

    Capsules consisting of a liquid droplet enclosed by a thin polymerized membrane are commonly encountered in nature (cells) or in industrial process (pharmaceutical, cosmetic or food products). The mechanical properties of the capsule wall are essential to guarantee the particle integrity and release of the internal contents when and where necessary. The difficulty is to assess the mechanical properties of the thin membrane. We will show how abrupt-step channels can be used to identify the membrane viscoelastic properties and point of rupture. This can be achieved by using a channel presenting a step change in cross-section and inverting the direction of the flow of the capsule suspension within the tube. To deduce information on the viscoelasticity, we will exploit the relaxation of the capsules as they flow through the expansion. To study membrane rupture, we will instead invert the channel, block the capsules at the neck of the constriction and determine the pressure difference needed for breakup. All the experiments will be conducted on initially spherical capsules with a thin cross-linked protein membrane for a proof of concept.

  18. 77 FR 45417 - Pipeline Safety: Inspection and Protection of Pipeline Facilities After Railway Accidents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-31

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... Accidents AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. [[Page 45418

  19. Anterior capsule tear after laser iridotomy complicating phacoemulsification

    PubMed Central

    Vivien Cherng Hui, Yip; Sanjay, Srinivasan; Benjamin Chong-Ming, Chang

    2011-01-01

    A 70-year-old Indian lady had a history of bilateral laser peripheral iridotomy (LPI) for primary angle closure. Subsequently she developed cataract in both the eyes. Right eye cataract surgery was complicated by an anterior capsule rupture, which was discovered intra-operatively at the site of the LPI. Trypan blue was used to stain the anterior capsule to delineate the anterior capsule defect. An attempt at continuous curvilinear capsulorhexis was unsuccessful, and the anterior capsulotomy was completed with scissors. To the best of our knowledge the surgical management of cataract in the presence of anterior capsule rupture as a result of LPI has not been reported. Awareness of this potential complication of LPI will aid in planning for successful phacoemulsification cataract surgery. PMID:23960943

  20. Antioxidant functionalized polymer capsules to prevent oxidative stress.

    PubMed

    Larrañaga, Aitor; Isa, Isma Liza Mohd; Patil, Vaibhav; Thamboo, Sagana; Lomora, Mihai; Fernández-Yague, Marc A; Sarasua, Jose-Ramon; Palivan, Cornelia G; Pandit, Abhay

    2018-02-01

    Polymeric capsules exhibit significant potential for therapeutic applications as microreactors, where the bio-chemical reactions of interest are efficiently performed in a spatial and time defined manner due to the encapsulation of an active biomolecule (e.g., enzyme) and control over the transfer of reagents and products through the capsular membrane. In this work, catalase loaded polymer capsules functionalized with an external layer of tannic acid (TA) are fabricated via a layer-by-layer approach using calcium carbonate as a sacrificial template. The capsules functionalised with TA exhibit a higher scavenging capacity for hydrogen peroxide and hydroxyl radicals, suggesting that the external layer of TA shows intrinsic antioxidant properties, and represents a valid strategy to increase the overall antioxidant potential of the developed capsules. Additionally, the hydrogen peroxide scavenging capacity of the capsules is enhanced in the presence of the encapsulated catalase. The capsules prevent oxidative stress in an in vitro inflammation model of degenerative disc disease. Moreover, the expression of matrix metalloproteinase-3 (MMP-3), and disintegrin and metalloproteinase with thrombospondin motif-5 (ADAMTS-5), which represents the major proteolytic enzymes in intervertebral disc, are attenuated in the presence of the polymer capsules. This platform technology exhibits potential to reduce oxidative stress, a key modulator in the pathology of a broad range of inflammatory diseases. Oxidative stress damages important cell structures leading to cellular apoptosis and senescence, for numerous disease pathologies including cancer, neurodegeneration or osteoarthritis. Thus, the development of biomaterials-based systems to control oxidative stress has gained an increasing interest. Herein, polymer capsules loaded with catalase and functionalized with an external layer of tannic acid are fabricated, which can efficiently scavenge important reactive oxygen species (i

  1. Series Pneumatic Artificial Muscles (sPAMs) and Application to a Soft Continuum Robot.

    PubMed

    Greer, Joseph D; Morimoto, Tania K; Okamura, Allison M; Hawkes, Elliot W

    2017-01-01

    We describe a new series pneumatic artificial muscle (sPAM) and its application as an actuator for a soft continuum robot. The robot consists of three sPAMs arranged radially round a tubular pneumatic backbone. Analogous to tendons, the sPAMs exert a tension force on the robot's pneumatic backbone, causing bending that is approximately constant curvature. Unlike a traditional tendon driven continuum robot, the robot is entirely soft and contains no hard components, making it safer for human interaction. Models of both the sPAM and soft continuum robot kinematics are presented and experimentally verified. We found a mean position accuracy of 5.5 cm for predicting the end-effector position of a 42 cm long robot with the kinematic model. Finally, closed-loop control is demonstrated using an eye-in-hand visual servo control law which provides a simple interface for operation by a human. The soft continuum robot with closed-loop control was found to have a step-response rise time and settling time of less than two seconds.

  2. Series Pneumatic Artificial Muscles (sPAMs) and Application to a Soft Continuum Robot

    PubMed Central

    Greer, Joseph D.; Morimoto, Tania K.; Okamura, Allison M.; Hawkes, Elliot W.

    2017-01-01

    We describe a new series pneumatic artificial muscle (sPAM) and its application as an actuator for a soft continuum robot. The robot consists of three sPAMs arranged radially round a tubular pneumatic backbone. Analogous to tendons, the sPAMs exert a tension force on the robot’s pneumatic backbone, causing bending that is approximately constant curvature. Unlike a traditional tendon driven continuum robot, the robot is entirely soft and contains no hard components, making it safer for human interaction. Models of both the sPAM and soft continuum robot kinematics are presented and experimentally verified. We found a mean position accuracy of 5.5 cm for predicting the end-effector position of a 42 cm long robot with the kinematic model. Finally, closed-loop control is demonstrated using an eye-in-hand visual servo control law which provides a simple interface for operation by a human. The soft continuum robot with closed-loop control was found to have a step-response rise time and settling time of less than two seconds. PMID:29379672

  3. Flake-shell capsules: adjustable inorganic structures.

    PubMed

    Ji, Qingmin; Guo, Chunyan; Yu, Xiaoyan; Ochs, Christopher J; Hill, Jonathan P; Caruso, Frank; Nakazawa, Hiromoto; Ariga, Katsuhiko

    2012-08-06

    Structure-adjustable capsules are fabricated from inorganic components by using a self-template dissolution-regrowth mechanism to give flake-shell silica microcapsules. The capsules shrink under thermal stimulus and their structures can be adjusted by treatment at different pH values. Tuning of shell pore diameters leads to tailored drug release over prolonged periods. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. 76 FR 28326 - Pipeline Safety: National Pipeline Mapping System Data Submissions and Submission Dates for Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR 191... Reports AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Issuance of... Pipeline and Hazardous Materials Safety Administration (PHMSA) published a final rule on November 26, 2010...

  5. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    PubMed

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Improvement in Capsule Abort Performance Using Supersonic Aerodynamic Interaction by Fences

    NASA Astrophysics Data System (ADS)

    Koyama, Hiroto; Wang, Yunpeng; Ozawa, Hiroshi; Doi, Katsunori; Nakamura, Yoshiaki

    The space transportation system will need advanced abort systems to secure crew against serious accidents. Here this study deals with the capsule-type space transportation systems with a Launch Abort System (LAS). This system is composed of a conic capsule as a Launch Abort Vehicle (LAV) and a cylindrical rocket as a Service Module (SM), and the capsule is moved away from the rocket by supersonic aerodynamic interactions in an emergency. We propose a method to improve the performance of the LAV by installing fences at the edges of surfaces on the rocket and capsule sides. Their effects were investigated by experimental measurements and numerical simulations. Experimental results show that the fences on the rocket and capsule surfaces increase the aerodynamic thrust force on the capsule by 70% in a certain clearance between the capsule and rocket. Computational results show the detailed flow fields where the centripetal flow near the surface on the rocket side is induced by the fence on the rocket side and the centrifugal flow near the surface on the capsule side is blocked by the fence on the capsule side. These results can confirm favorable effects of the fences on the performance of the LAS.

  7. Engineering multifunctional capsules through the assembly of metal-phenolic networks.

    PubMed

    Guo, Junling; Ping, Yuan; Ejima, Hirotaka; Alt, Karen; Meissner, Mirko; Richardson, Joseph J; Yan, Yan; Peter, Karlheinz; von Elverfeldt, Dominik; Hagemeyer, Christoph E; Caruso, Frank

    2014-05-26

    Metal-organic coordination materials are of widespread interest because of the coupled benefits of inorganic and organic building blocks. These materials can be assembled into hollow capsules with a range of properties, which include selective permeability, enhanced mechanical/thermal stability, and stimuli-responsiveness. Previous studies have primarily focused on the assembly aspects of metal-coordination capsules; however, the engineering of metal-specific functionality for capsule design has not been explored. A library of functional metal-phenolic network (MPN) capsules prepared from a phenolic ligand (tannic acid) and a range of metals is reported. The properties of the MPN capsules are determined by the coordinated metals, allowing for control over film thickness, disassembly characteristics, and fluorescence behavior. Furthermore, the functional properties of the MPN capsules were tailored for drug delivery, positron emission tomography (PET), magnetic resonance imaging (MRI), and catalysis. The ability to incorporate multiple metals into MPN capsules demonstrates that a diverse range of functional materials can be generated. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Bioequivalence of a methylphenidate hydrochloride extended-release preparation: comparison of an intact capsule and an opened capsule sprinkled on applesauce.

    PubMed

    Fischer, R; Schütz, H; Grossmann, M; Leis, H J; Ammer, R

    2006-03-01

    To assess bioequivalence between an intact capsule and the content of a capsule sprinkled on applesauce. Medikinet retard 20 mg capsules were obtained from Medice (Iserlohn, Germany). This was a single-center, completely randomized, open, 2-period, 2-sequence, balanced crossover study with a washout period of 1 week between administrations, in 12 healthy male and female subjects, aged 18-45 years. Blood samples were collected over 24 hours and methylphenidate plasma concentration-time data were used to calculate pharmacokinetic parameters for both administrations. The main parameters were (confirmatory) AUC0-tz (extent of BA), Cmax, tmax (rate of BA) and (descriptively) AUC0-infinity and t1/2. Equivalence was concluded if the 90% confidence interval (CI) for the ratio between test and reference was 0.80-1.25 (AUC0-tz). All 12 dosed subjects finished both treatment periods and were included in pharmacokinetic and safety analyses. 90% geometric confidence intervals for AUC0-tz and Cmax data were well within accepted bioequivalence limits. The study has shown that both treatment modes lead to similar pattern of absorption and elimination following single-dose administration in the fed state. The test treatment (content of capsule sprinkled over 15 ml applesauce) is bioequivalent to the reference treatment (intact capsule) in terms of extent and rate of absorption. Data collected from this study demonstrate that Medikinet retard capsules can be opened and the content sprinkled on a tablespoon of applesauce without influencing the rate and extent of bioavailability.

  9. 76 FR 31584 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Extension of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ...-the-Road Tires From the People's Republic of China: Extension of Preliminary Results of Antidumping... for the preliminary results of the administrative review of certain new pneumatic off-the-road tires... on certain new pneumatic off-the-road tires from the PRC. See Initiation of Antidumping and...

  10. Spectral measurements of asymmetrically irradiated capsule backlighters

    DOE PAGES

    Keiter, P. A.; Drake, R. P.

    2016-09-09

    Capsule backlighters provide a quasi-continuum x-ray spectrum over a wide range of photon energies. Ideally one irradiates the capsule backlighter symmetrically, however, in complex experimental geometries, this is not always possible. In recent experiments we irradiated capsule backlighters asymmetrically and measured the x-ray spectrum from multiple directions. We will present time-integrated spectra over the photon energy range of ~2-13 keV and time-resolved spectra over the photon energy range of ~2-3 keV. Lastly, we will compare the spectra from different lines of sight to determine if the laser asymmetry results in an angular dependence in the x-ray emission.

  11. Lateral instability of high temperature pipelines, the 20-in. Sleipner Vest pipeline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saevik, S.; Levold, E.; Johnsen, O.K.

    1996-12-01

    The present paper addresses methods to control snaking behavior of high temperature pipelines resting on a flat sea bed. A case study is presented based on the detail engineering of the 12.5 km long 20 inch gas pipeline connecting the Sleipner Vest wellhead platform to the Sleipner T processing platform in the North Sea. The study includes screening and evaluation of alternative expansion control methods, ending up with a recommended method. The methodology and philosophy, used as basis to ensure sufficient structural strength throughout the lifetime of the pipeline, are thereafter presented. The results show that in order to findmore » the optimum technical solution to control snaking behavior, many aspects need to be considered such as process requirements, allowable strain, hydrodynamic stability, vertical profile, pipelay installation and trawlboard loading. It is concluded that by proper consideration of all the above aspects, the high temperature pipeline can be designed to obtain sufficient safety level.« less

  12. State diagram for adhesion dynamics of deformable capsules under shear flow.

    PubMed

    Luo, Zheng Yuan; Bai, Bo Feng

    2016-08-17

    Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca < 0.0075), whole-capsule deformation confers the capsule a flattened bottom in contact with the functionalized surface, which hence promotes the rolling-to-firm-adhesion transition. It is consistent with the observations from previous studies that cell deformation promotes the adhesion of cells lying in the rolling regime. However, it is surprising to find that, at relatively high capillary numbers (e.g. 0.0075 < Ca < 0.0175), the effect of capsule deformability on its adhesion dynamics is far more complex than just promoting adhesion. High deformability of capsules makes their bottom take a concave shape with no adhesion bond formation in the middle. The appearance of this specific capsule shape inhibits the transitions of both rolling-to-firm-adhesion and detachment-to-rolling, and it means that capsule deformation no longer promotes the capsule adhesion. Besides, it is interesting to note that, when the capillary number exceeds a critical value (e.g. Ca = 0.0175), the rolling state no longer appears, since capsules exhibit large deviation from the spherical shape.

  13. Hydraulic anisotropy characterization of pneumatic-fractured sediments using azimuthal self potential gradient

    USGS Publications Warehouse

    Wishart, D.N.; Slater, L.D.; Schnell, D.L.; Herman, G.C.

    2009-01-01

    The pneumatic fracturing technique is used to enhance the permeability and porosity of tight unconsolidated soils (e.g. clays), thereby improving the effectiveness of remediation treatments. Azimuthal self potential gradient (ASPG) surveys were performed on a compacted, unconsolidated clay block in order to evaluate their potential to delineate contaminant migration pathways in a mechanically-induced fracture network. Azimuthal resistivity (ARS) measurements were also made for comparative purposes. Following similar procedures to those used in the field, compressed kaolinite sediments were pneumatically fractured and the resulting fracture geometry characterized from strike analysis of visible fractures combined with strike data from optical borehole televiewer (BHTV) imaging. We subsequently injected a simulated treatment (electrolyte/dye) into the fractures. Both ASPG and ARS data exhibit anisotropic geoelectric signatures resulting from the fracturing. Self potentials observed during injection of electrolyte are consistent with electrokinetic theory and previous laboratory results on a fracture block model. Visual (polar plot) analysis and linear regression of cross plots show ASPG lobes are correlated with azimuths of high fracture strike density, evidence that the ASPG anisotropy is a proxy measure of hydraulic anisotropy created by the pneumatic fracturing. However, ARS data are uncorrelated with fracture strike maxima and resistivity anisotropy is probably dominated by enhanced surface conduction along azimuths of weak 'starter paths' formed from pulverization of the clay and increases in interfacial surface area. We find the magnitude of electrokinetic SP scales with the applied N2 gas pressure gradient (??PN2) for any particular hydraulically-active fracture set and that the positive lobe of the ASPG anomaly indicates the flow direction within the fracture network. These findings demonstrate the use of ASPG in characterizing the effectiveness of (1

  14. Magnetized HDC ignition capsules for yield enhancement and implosion magnetohydrodynamics

    NASA Astrophysics Data System (ADS)

    Zimmerman, G.; Ho, D.; Perkins, J.; Logan, G.; Hawkins, S.; Rhodes, M.

    2014-10-01

    Imposing a magnetic field on capsules can turn capsules that fail, because of low 1-D margin, into igniting capsules that give yield in the MegaJoule range. The imposed magnetic field can be amplified by up to O(103) as it is being compressed by the imploding shell, e.g. if the initial field is 50 T, then the field in the hot spot of the assembled configuration can reach >104 T. (We are currently designing hardware that can provide a field in the 50 T range inside NIF hohlraums.) With this highly compressed field strength, the gyro radius of alpha particles becomes smaller than the hot spot size. Consequently, the heating of the hot spot becomes more efficient. The imposed field can also prevent hot electrons in the holhraum from reaching the capsule. We choose capsules with high-density carbon (HDC) ablators for this study. HDC capsules have good 1-D performance and also have short pulses (10 ns or less), allowing the use of low gas-filled or near-vacuum hohlraums which provide high coupling efficiency. We describe a 2-D simulation of a 3-shock HDC capsule. We will show detailed magnetohydrodynamic evolution of the implosion. HDC capsules with 2-shock pulses have low margin because of their high adiabat, and it is difficult to achieve ignition in realistic 2-D simulations. The improvement in performance for 2-shock magnetized capsules will be presented. This work was supported by LLNL Laboratory Directed Research and Development LDRD 14-ER-028 under Contract DE-AC52-07NA27344.

  15. The Hyper Suprime-Cam software pipeline

    NASA Astrophysics Data System (ADS)

    Bosch, James; Armstrong, Robert; Bickerton, Steven; Furusawa, Hisanori; Ikeda, Hiroyuki; Koike, Michitaro; Lupton, Robert; Mineo, Sogo; Price, Paul; Takata, Tadafumi; Tanaka, Masayuki; Yasuda, Naoki; AlSayyad, Yusra; Becker, Andrew C.; Coulton, William; Coupon, Jean; Garmilla, Jose; Huang, Song; Krughoff, K. Simon; Lang, Dustin; Leauthaud, Alexie; Lim, Kian-Tat; Lust, Nate B.; MacArthur, Lauren A.; Mandelbaum, Rachel; Miyatake, Hironao; Miyazaki, Satoshi; Murata, Ryoma; More, Surhud; Okura, Yuki; Owen, Russell; Swinbank, John D.; Strauss, Michael A.; Yamada, Yoshihiko; Yamanoi, Hitomi

    2018-01-01

    In this paper, we describe the optical imaging data processing pipeline developed for the Subaru Telescope's Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope's Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrending and image characterizations.

  16. 77 FR 4996 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ...-the-Road Tires From the People's Republic of China: Rescission of Countervailing Duty Administrative... countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People's Republic of..., Office 6, ``Administrative Review of the Countervailing Duty Order on Certain New Pneumatic Off-the-road...

  17. 75 FR 46917 - New Pneumatic Off-the-Road Tires from the People's Republic of China: Notice of Partial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-04

    ... DEPARTMENT OF COMMERCE International Trade Administration (A-570-912) New Pneumatic Off-the-Road.... EFFECTIVE DATE: August 4, 2010. FOR FURTHER INFORMATION CONTACT: Andrea Staebler Berton or Raquel Silva, AD... review of the antidumping duty order on new pneumatic off-the-road tires (``OTR tires'') from the People...

  18. Identification of the duodenal papilla by colon capsule endoscope.

    PubMed

    Karagiannis, S; Dücker, C; Dautel, P; Strubenhoff, J; Faiss, S

    2010-07-01

    The sensitivity of small-bowel capsule endoscopy in visualizing a single finding present in everyone, the duodenal papilla, is limited. In this retrospective case series study we evaluated whether the duodenal papilla can be better visualized by a capsule endoscope equipped with cameras on both ends. The recordings of 45 colonic capsule endoscopies (PillCam Colon) performed in a single tertiary center were re-evaluated seeking for the duodenal papilla. The two-hour sleeping period of the colon capsule endoscopy system led to the imaging of duodenum in 10 / 45 patients. The duodenal papilla was identified in 6 / 10 (60 %) patients while the number of frames where the papilla was clearly visualized ranged from 2 - 9. Consequently, a small-bowel capsule endoscope containing two cameras could better identify the duodenal papilla and theoretically other obscure areas of the small bowel, expanding its diagnostic accuracy.

  19. Laundry detergent capsules and pediatric poisoning.

    PubMed

    Bonney, Asha G; Mazor, Suzan; Goldman, Ran D

    2013-12-01

    A 4-year-old girl was brought into the emergency department vomiting after having had ingested a laundry detergent capsule (LDC) from under the sink at her house. What is the risk of LDC poisoning? What can be done to treat these children? Laundry detergent capsules are relatively new to supermarket shelves in North America, and there has been an emergence of case reports in the literature describing LDC poisoning, which is worse than poisoning from other laundry detergents. Very little is known about the mechanisms causing these severe reactions, which include airway compromise and esophageal perforation, but the attractive appearance of these capsules and easy access at home has governments and health officials concerned about an increase in poisoning. No residual problems have been associated with these cases to date; however, further research is needed to assess long-term effects.

  20. The Influence of Shaping Air Pressure of Pneumatic Spray Gun

    NASA Astrophysics Data System (ADS)

    Chen, Wenzhuo; Chen, Yan; Pan, Haiwei; Zhang, Weiming; Li, Bo

    2018-02-01

    The shaping air pressure is a very important parameter in the application of pneumatic spray gun, and studying its influence on spray flow field and film thickness distribution has practical values. In this paper, Euler-Lagrangian method is adopted to describe the two-phase spray flow of pneumatic painting process, and the air flow fields, spray patterns and dynamic film thickness distributions were obtained with the help of the computational fluid dynamics code—ANSYS Fluent. Results show that with the increase of the shaping air pressure, the air phase flow field spreads in the plane perpendicular to the shaping air hole plane, the spray pattern becomes narrower and flatter, and the width of the dynamic film increases with the reduced maximum value of the film thickness. But the film thickness distribution seems to change little with the shaping air pressure decreasing from 0.6bar to 0.9bar.

  1. 78 FR 53190 - Pipeline Safety: Notice to Operators of Hazardous Liquid and Natural Gas Pipelines of a Recall on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2013-0185] Pipeline Safety: Notice to Operators of Hazardous Liquid and Natural Gas Pipelines of a Recall on Leak Repair Clamps Due to Defective Seal AGENCY: Pipeline and Hazardous Materials Safety...

  2. DDBJ read annotation pipeline: a cloud computing-based pipeline for high-throughput analysis of next-generation sequencing data.

    PubMed

    Nagasaki, Hideki; Mochizuki, Takako; Kodama, Yuichi; Saruhashi, Satoshi; Morizaki, Shota; Sugawara, Hideaki; Ohyanagi, Hajime; Kurata, Nori; Okubo, Kousaku; Takagi, Toshihisa; Kaminuma, Eli; Nakamura, Yasukazu

    2013-08-01

    High-performance next-generation sequencing (NGS) technologies are advancing genomics and molecular biological research. However, the immense amount of sequence data requires computational skills and suitable hardware resources that are a challenge to molecular biologists. The DNA Data Bank of Japan (DDBJ) of the National Institute of Genetics (NIG) has initiated a cloud computing-based analytical pipeline, the DDBJ Read Annotation Pipeline (DDBJ Pipeline), for a high-throughput annotation of NGS reads. The DDBJ Pipeline offers a user-friendly graphical web interface and processes massive NGS datasets using decentralized processing by NIG supercomputers currently free of charge. The proposed pipeline consists of two analysis components: basic analysis for reference genome mapping and de novo assembly and subsequent high-level analysis of structural and functional annotations. Users may smoothly switch between the two components in the pipeline, facilitating web-based operations on a supercomputer for high-throughput data analysis. Moreover, public NGS reads of the DDBJ Sequence Read Archive located on the same supercomputer can be imported into the pipeline through the input of only an accession number. This proposed pipeline will facilitate research by utilizing unified analytical workflows applied to the NGS data. The DDBJ Pipeline is accessible at http://p.ddbj.nig.ac.jp/.

  3. DDBJ Read Annotation Pipeline: A Cloud Computing-Based Pipeline for High-Throughput Analysis of Next-Generation Sequencing Data

    PubMed Central

    Nagasaki, Hideki; Mochizuki, Takako; Kodama, Yuichi; Saruhashi, Satoshi; Morizaki, Shota; Sugawara, Hideaki; Ohyanagi, Hajime; Kurata, Nori; Okubo, Kousaku; Takagi, Toshihisa; Kaminuma, Eli; Nakamura, Yasukazu

    2013-01-01

    High-performance next-generation sequencing (NGS) technologies are advancing genomics and molecular biological research. However, the immense amount of sequence data requires computational skills and suitable hardware resources that are a challenge to molecular biologists. The DNA Data Bank of Japan (DDBJ) of the National Institute of Genetics (NIG) has initiated a cloud computing-based analytical pipeline, the DDBJ Read Annotation Pipeline (DDBJ Pipeline), for a high-throughput annotation of NGS reads. The DDBJ Pipeline offers a user-friendly graphical web interface and processes massive NGS datasets using decentralized processing by NIG supercomputers currently free of charge. The proposed pipeline consists of two analysis components: basic analysis for reference genome mapping and de novo assembly and subsequent high-level analysis of structural and functional annotations. Users may smoothly switch between the two components in the pipeline, facilitating web-based operations on a supercomputer for high-throughput data analysis. Moreover, public NGS reads of the DDBJ Sequence Read Archive located on the same supercomputer can be imported into the pipeline through the input of only an accession number. This proposed pipeline will facilitate research by utilizing unified analytical workflows applied to the NGS data. The DDBJ Pipeline is accessible at http://p.ddbj.nig.ac.jp/. PMID:23657089

  4. 77 FR 19414 - Pipeline Safety: Public Comment on Leak and Valve Studies Mandated by the Pipeline Safety...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID... Safety, Regulatory Certainty, and Job Creation Act of 2011 AGENCY: Pipeline and Hazardous Materials... Transportation (DOT), Pipeline and Hazardous Materials Safety Administration (PHMSA) is providing an important...

  5. Lens capsule structure assessed with atomic force microscopy

    PubMed Central

    Sueiras, Vivian M.; Moy, Vincent T.

    2015-01-01

    Purpose To image the ultrastructure of the anterior lens capsule at the nanoscale level using atomic force microscopy (AFM). Methods Experiments were performed on anterior lens capsules maintained in their in situ location surrounding the lens from six human cadavers (donor age range: 44–88 years), four cynomolgus monkeys (Macaca fascicularis age range: 4.83–8.92 years), and seven pigs (<6 months). Hydration of all samples was maintained using Dulbecco’s Modified Eagle Medium (DMEM). Whole lenses were removed from the eye and placed anterior side up in agarose gel before gel hardening where only the posterior half of the lens was contained within the gel. After the gel hardened, the Petri dish was filled with DMEM until the point where the intact lens was fully submerged. AFM was used to image the anterior lens surface in contact mode. An integrated analysis program was used to calculate the interfibrillar spacing, fiber diameter, and surface roughness of the samples. Results The AFM images depict a highly ordered fibrous structure at the surface of the lens capsule in all three species. The interfibrillar spacing for the porcine, cynomolgus monkey, and human lens capsules was 0.68±0.25, 1.80±0.39, and 1.08±0.25 μm, respectively. In the primate, interfibrillar spacing significantly decreased linearly as a function of age. The fiber diameters ranged from 50 to 950 nm. Comparison of the root mean square (RMS) and average deviation demonstrate that the surface of the porcine lens capsule is the smoothest, and that the human and cynomolgus monkey capsules are significantly rougher. Conclusions AFM was successful in providing high-resolution images of the nanostructure of the lens capsule samples. Species-dependent differences were observed in the overall structure and surface roughness. PMID:25814829

  6. Capsule endoscopy in the diagnosis of Crohn's disease.

    PubMed

    Niv, Yaron

    2013-01-01

    Crohn's disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn's disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn's disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn's disease. Recently, we have developed and validated the Capsule Endoscopy Crohn's Disease Activity Index (also known as the Niv score) for Crohn's disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn's ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn's disease.

  7. Forces associated with pneumatic power screwdriver operation: statics and dynamics.

    PubMed

    Lin, Jia-Hua; Radwin, Robert G; Fronczak, Frank J; Richard, Terry G

    2003-10-10

    The statics and dynamics of pneumatic power screwdriver operation were investigated in the context of predicting forces acting against the human operator. A static force model is described in the paper, based on tool geometry, mass, orientation in space, feed force, torque build up, and stall torque. Three common power hand tool shapes are considered, including pistol grip, right angle, and in-line. The static model estimates handle force needed to support a power nutrunner when it acts against the tightened fastener with a constant torque. A system of equations for static force and moment equilibrium conditions are established, and the resultant handle force (resolved in orthogonal directions) is calculated in matrix form. A dynamic model is formulated to describe pneumatic motor torque build-up characteristics dependent on threaded fastener joint hardness. Six pneumatic tools were tested to validate the deterministic model. The average torque prediction error was 6.6% (SD = 5.4%) and the average handle force prediction error was 6.7% (SD = 6.4%) for a medium-soft threaded fastener joint. The average torque prediction error was 5.2% (SD = 5.3%) and the average handle force prediction error was 3.6% (SD = 3.2%) for a hard threaded fastener joint. Use of these equations for estimating handle forces based on passive mechanical elements representing the human operator is also described. These models together should be useful for considering tool handle force in the selection and design of power screwdrivers, particularly for minimizing handle forces in the prevention of injuries and work related musculoskeletal disorders.

  8. Role of capsule endoscopy in inflammatory bowel disease.

    PubMed

    Kopylov, Uri; Seidman, Ernest G

    2014-02-07

    Videocapsule endoscopy (VCE) has revolutionized our ability to visualize the small bowel mucosa. This modality is a valuable tool for the diagnosis of obscure small bowel Crohn's disease (CD), and can also be used for monitoring of disease activity in patients with established small-bowel CD, detection of complications such as obscure bleeding and neoplasms, evaluation of response to anti-inflammatory treatment and postoperative recurrence following small bowel resection. VCE could also be an important tool in the management of patients with unclassified inflammatory bowel disease, potentially resulting in reclassification of these patients as having CD. Reports on postoperative monitoring and evaluation of patients with ileal pouch-anal anastomosis who have developed pouchitis have recenty been published. Monitoring of colonic inflammatory activity in patients with ulcerative colitis using the recently developed colonic capsule has also been reported. Capsule endoscopy is associated with an excellent safety profile. Although retention risk is increased in patients with small bowel CD, this risk can be significanty decreased by a routine utilization of a dissolvable patency capsule preceding the ingestion of the diagnostic capsule. This paper contains an overview of the current and future clinical applications of capsule endoscopy in inflammatory bowel disease.

  9. 78 FR 33059 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ...-the-Road Tires From the People's Republic of China: Rescission of Antidumping Duty Administrative... order on certain new pneumatic off-the-road tires from the People's Republic of China (``PRC'') for the... antidumping duty order on certain new pneumatic off-the-road tires, with respect to the above-named companies...

  10. 76 FR 7816 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ...-the-Road Tires From the People's Republic of China: Rescission of Countervailing Duty Administrative... countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People's Republic of... withdrawal of its request for review. See Certain New Pneumatic Off-the-Road Tires From the People's Republic...

  11. Rotary Actuators Based on Pneumatically Driven Elastomeric Structures.

    PubMed

    Gong, Xiangyu; Yang, Ke; Xie, Jingjin; Wang, Yanjun; Kulkarni, Parth; Hobbs, Alexander S; Mazzeo, Aaron D

    2016-09-01

    Unique elastomeric rotary actuators based on pneumatically driven peristaltic motion are demonstrated. Using silicone-based wheels, these motors enable a new class of soft locomotion not found in nature, which is capable of withstanding impact, traversing irregular terrain, and operating in water. For soft robotics, this work marks progress toward providing torque without bending actuators. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Ultrasound capsule endoscopy: sounding out the future

    PubMed Central

    Stewart, Fraser; Lay, Holly; Cummins, Gerard; Newton, Ian P.; Desmulliez, Marc P. Y.; Steele, Robert J. C.; Näthke, Inke; Cochran, Sandy

    2017-01-01

    Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently. PMID:28567381

  13. U.S. pipeline industry enters new era

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnsen, M.R.

    1999-11-01

    The largest construction project in North America this year and next--the Alliance Pipeline--marks some advances for the US pipeline industry. With the Alliance Pipeline system (Alliance), mechanized welding and ultrasonic testing are making their debuts in the US as primary mainline construction techniques. Particularly in Canada and Europe, mechanized welding technology has been used for both onshore and offshore pipeline construction for at least 15 years. However, it has never before been used to build a cross-country pipeline in the US, although it has been tested on short segments. This time, however, an accelerated construction schedule, among other reasons, necessitatedmore » the use of mechanized gas metal arc welding (GMAW). The $3-billion pipeline will delivery natural gas from northwestern British Columbia and northeastern Alberta in Canada to a hub near Chicago, Ill., where it will connect to the North American pipeline grid. Once the pipeline is completed and buried, crews will return the topsoil. Corn and other crops will reclaim the land. While the casual passerby probably won't know the Alliance pipeline is there, it may have a far-reaching effect on the way mainline pipelines are built in the US. For even though mechanized welding and ultrasonic testing are being used for the first time in the United States on this project, some US workers had already gained experience with the technology on projects elsewhere. And work on this pipeline has certainly developed a much larger pool of experienced workers for industry to draw from. The Alliance project could well signal the start of a new era in US pipeline construction.« less

  14. Unsteady Pressures on a Generic Capsule Shape

    NASA Technical Reports Server (NTRS)

    Burnside, Nathan; Ross, James C.

    2015-01-01

    While developing the aerodynamic database for the Orion spacecraft, the low-speed flight regime (transonic and below) proved to be the most difficult to predict and measure accurately. The flow over the capsule heat shield in descent flight was particularly troublesome for both computational and experimental efforts due to its unsteady nature and uncertainty about the boundary layer state. The data described here were acquired as part of a study to improve the understanding of the overall flow around a generic capsule. The unsteady pressure measurements acquired on a generic capsule shape are presented along with a discussion about the effects of various flight conditions and heat-shield surface roughness on the resulting pressure fluctuations.

  15. Pneumatic Distension of Ventricular Mural Architecture Validated Histologically.

    PubMed

    Burg, M C; Lunkenheimer, P; Niederer, P; Brune, C; Redmann, K; Smerup, M; Spiegel, U; Becker, F; Maintz, D; Heindel, W; Anderson, R H

    2016-11-01

    Purpose: There are ongoing arguments as to how cardiomyocytes are aggregated together within the ventricular walls. We used pneumatic distension through the coronary arteries to exaggerate the gaps between the aggregated cardiomyocytes, analyzing the pattern revealed using computed tomography, and validating our findings by histology. Methods: We distended 10 porcine hearts, arresting 4 in diastole by infusion of cardioplegic solutions, and 4 in systole by injection of barium chloride. Mural architecture was revealed by computed tomography, measuring also the angulations of the long chains of cardiomyocytes. We prepared the remaining 2 hearts for histology by perfusion with formaldehyde. Results: Increasing pressures of pneumatic distension elongated the ventricular walls, but produced insignificant changes in mural thickness. The distension exaggerated the spaces between the aggregated cardiomyocytes, compartmenting the walls into epicardial, central, and endocardial regions, with a feathered arrangement of transitions between them. Marked variation was noted in the thicknesses of the parts in the different ventricular segments, with no visible anatomical boundaries between them. Measurements of angulations revealed intruding and extruding populations of cardiomyocytes that deviated from a surface-parallel alignment. Scrolling through the stacks of tomographic images revealed marked spiraling of the aggregated cardiomyocytes when traced from base to apex. Conclusion: Our findings call into question the current assumption that cardiomyocytes are uniformly aggregated together in a tangential fashion. There is marked heterogeneity in the architecture of the different ventricular segments, with the aggregated units never extending in a fully transmural fashion. Key Points: • Pneumographic computed tomography reveals an organized structure of the ventricular walls.• Aggregated cardiomyocytes form a structured continuum, with marked regional heterogeneity

  16. A locomotion mechanism with external magnetic guidance for active capsule endoscope.

    PubMed

    Wang, Xiaona; Meng, Max Q H; Chen, Xijun

    2010-01-01

    Gastrointestinal (GI) disorder is one of the most common diseases in human body. The swallowable wireless capsule endoscopy has been proved to be a convenient, painless and effective way to examine the whole GI tract. However, lack of motion control makes the movement of the capsule substantially random, resulting in missing diagnosis. In this paper, a locomotion mechanism is developed for the next-generation active capsule endoscope. An internal actuator integrated on-board the capsule is designed to provide driving force and improve the dexterity. A small permanent magnet enclosed inside the capsule interacts with an external magnetic field to control the capsule's orientation and offer extra driving force. This mechanism avoids sophisticated and bulky control system and reduces power consumption inside the capsule. Ex-vivo experimental results showed that it can make a controllable movement inside the porcine large intestine. The mechanism also has the potential to be a platform for further development, such as devices of operations, spraying medicine, biopsy etc.

  17. Additional Development and Systems Analyses of Pneumatic Technology for High Speed Civil Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Willie, F. Scott; Lee, Warren J.

    1999-01-01

    In the Task I portion of this NASA research grant, configuration development and experimental investigations have been conducted on a series of pneumatic high-lift and control surface devices applied to a generic High Speed Civil Transport (HSCT) model configuration to determine their potential for improved aerodynamic performance, plus stability and control of higher performance aircraft. These investigations were intended to optimize pneumatic lift and drag performance; provide adequate control and longitudinal stability; reduce separation flowfields at high angle of attack; increase takeoff/climbout lift-to-drag ratios; and reduce system complexity and weight. Experimental aerodynamic evaluations were performed on a semi-span HSCT generic model with improved fuselage fineness ratio and with interchangeable plain flaps, blown flaps, pneumatic Circulation Control Wing (CCW) high-lift configurations, plain and blown canards, a novel Circulation Control (CC) cylinder blown canard, and a clean cruise wing for reference. Conventional tail power was also investigated for longitudinal trim capability. Also evaluated was unsteady pulsed blowing of the wing high-lift system to determine if reduced pulsed mass flow rates and blowing requirements could be made to yield the same lift as that resulting from steady-state blowing. Depending on the pulsing frequency applied, reduced mass flow rates were indeed found able to provide lift augmentation at lesser blowing values than for the steady conditions. Significant improvements in the aerodynamic characteristics leading to improved performance and stability/control were identified, and the various components were compared to evaluate the pneumatic potential of each. Aerodynamic results were provided to the Georgia Tech Aerospace System Design Lab. to conduct the companion system analyses and feasibility study (Task 2) of theses concepts applied to an operational advanced HSCT aircraft. Results and conclusions from these

  18. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    USDA-ARS?s Scientific Manuscript database

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  19. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    USDA-ARS?s Scientific Manuscript database

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  20. Pneumatic vacuum tube message center, basement room 23, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  1. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  2. The Hyper Suprime-Cam software pipeline

    DOE PAGES

    Bosch, James; Armstrong, Robert; Bickerton, Steven; ...

    2017-10-12

    Here in this article, we describe the optical imaging data processing pipeline developed for the Subaru Telescope’s Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope’s Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrendingmore » and image characterizations.« less

  3. The Hyper Suprime-Cam software pipeline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosch, James; Armstrong, Robert; Bickerton, Steven

    Here in this article, we describe the optical imaging data processing pipeline developed for the Subaru Telescope’s Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope’s Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrendingmore » and image characterizations.« less

  4. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    PubMed

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  5. Investigation of albumin-derived perfluorocarbon-based capsules by holographic optical trapping

    PubMed Central

    Köhler, Jannis; Ruschke, Jegor; Ferenz, Katja Bettina; Esen, Cemal; Kirsch, Michael; Ostendorf, Andreas

    2018-01-01

    Albumin-derived perfluorocarbon-based capsules are promising as artificial oxygen carriers with high solubility. However, these capsules have to be studied further to allow initial human clinical tests. The aim of this paper is to provide and characterize a holographic optical tweezer to enable contactless trapping and moving of individual capsules in an environment that mimics physiological (in vivo) conditions most effectively in order to learn more about the artificial oxygen carrier behavior in blood plasma without recourse to animal experiments. Therefore, the motion behavior of capsules in a ring shaped or vortex beam is analyzed and optimized on account of determination of the optical forces in radial and axial direction. In addition, due to the customization and generation of dynamic phase holograms, the optical tweezer is used for first investigations on the aggregation behavior of the capsules and a statistical evaluation of the bonding in dependency of different capsule sizes is performed. The results show that the optical tweezer is sufficient for studying individual perfluorocarbon-based capsules and provide information about the interaction of these capsules for future use as artificial oxygen carriers. PMID:29552409

  6. Pneumatic pressure wave generator provides economical, simple testing of pressure transducers

    NASA Technical Reports Server (NTRS)

    Gaal, A. E.; Weldon, T. P.

    1967-01-01

    Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.

  7. Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval.

    PubMed

    Van Weyenberg, Stijn J B; Van Turenhout, Sietze T; Bouma, Gerd; Van Waesberghe, Jan Hein T M; Van der Peet, Donald L; Mulder, Chris J J; Jacobs, Maarten A J M

    2010-03-01

    Capsule retention in the small bowel is a known complication of small-bowel video capsule endoscopy. Surgery is the most frequently used method of capsule retrieval. To determine the incidence and causes of capsule retention and to describe double-balloon endoscopy (DBE) as the primary technique used for capsule retrieval. Retrospective analysis of all video capsule studies was performed at our center, and evaluation of the outcome of DBE was the first method used to retrieve entrapped video capsules. Tertiary referral center. A total of 904 patients who underwent small-bowel video capsule endoscopy. Capsule retrieval by DBE. The number of patients in whom capsule retention occurred and the number of patients in whom an entrapped capsule could be retrieved by using DBE. Capsule retention occurred in 8 patients (incidence 0.88%; 95% CI, 0.41%-1.80%) and caused acute small-bowel obstruction in 6 patients. All retained capsules were successfully removed during DBE. Five patients underwent elective surgery to treat the underlying cause of capsule retention. One patient required emergency surgery because of multiple small-bowel perforations. Retrospective design. In our series, the incidence of capsule retention was low. DBE is a reliable method for removing retained capsules and might prevent unnecessary surgery. If surgery is required, preoperative capsule retrieval allows preoperative diagnosis, adequate staging in case of malignancy, and optimal surgical planning. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  8. An instrumented object for hand exercise and assessment using a pneumatic pressure sensor

    NASA Astrophysics Data System (ADS)

    Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.

    2018-05-01

    Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.

  9. A durability study of a paracorporeal pulsatile electro-mechanical pneumatic biventricular assist device.

    PubMed

    Choi, Hyuk; Lee, Heung-Man; Nam, Kyoung Won; Choi, Jaesoon; Lee, Jung-Joo; Kim, Ho Chul; Song, Seung Joon; Ahn, Chi Bum; Son, Ho Sung; Lim, Choon Hak; Son, Kuk Hui; Park, Yong Doo; Jeong, Gi Seok; Sun, Kyung

    2011-06-01

    In 2002, the paracorporeal pulsatile electro-mechanical pneumatic ventricular assist device (VAD) began to be developed by the Korea Artificial Organ Center at Korea University under a Health & Medical Technology Research and Development program which finished in 2008. In vitro durability testing was conducted on the paracorporeal pulsatile pneumatic VAD to determine device durability and to evaluate device failures. The 1- and 2-year reliability of the paracorporeal pulsatile pneumatic VAD was shown to be 91.2% and 54.9%, respectively, with an 80% confidence level. Failure modes were analyzed using fault tree analysis, with customized software continuously acquiring data during the test period. After this period, 21 in vivo animal tests were done, with 14 cases of left atrium to left ventricle (LV) inflow cannulation (36Fr)/outflow grafting to descending aorta, and seven cases of apex cannulation of LV to descending aorta (12 mm). The longest postoperative day (182 days) in Korea was recently recorded in in vivo animal testing (bovine, 90 kg, male, 3.5-4.0 L/min flow rate, and 55 bpm). © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. A Novel Real-Time Path Servo Control of a Hardware-in-the-Loop for a Large-Stroke Asymmetric Rod-Less Pneumatic System under Variable Loads.

    PubMed

    Lin, Hao-Ting

    2017-06-04

    This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally.

  11. A Novel Real-Time Path Servo Control of a Hardware-in-the-Loop for a Large-Stroke Asymmetric Rod-Less Pneumatic System under Variable Loads

    PubMed Central

    Lin, Hao-Ting

    2017-01-01

    This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally. PMID:28587220

  12. Design of illumination system in ring field capsule endoscope

    NASA Astrophysics Data System (ADS)

    Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi

    2011-03-01

    This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.

  13. Laundry detergent capsules and pediatric poisoning

    PubMed Central

    Bonney, Asha G.; Mazor, Suzan; Goldman, Ran D.

    2013-01-01

    Abstract Question A 4-year-old girl was brought into the emergency department vomiting after having had ingested a laundry detergent capsule (LDC) from under the sink at her house. What is the risk of LDC poisoning? What can be done to treat these children? Answer Laundry detergent capsules are relatively new to supermarket shelves in North America, and there has been an emergence of case reports in the literature describing LDC poisoning, which is worse than poisoning from other laundry detergents. Very little is known about the mechanisms causing these severe reactions, which include airway compromise and esophageal perforation, but the attractive appearance of these capsules and easy access at home has governments and health officials concerned about an increase in poisoning. No residual problems have been associated with these cases to date; however, further research is needed to assess long-term effects. PMID:24336541

  14. Pipelining in a changing competitive environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, E.G.; Wishart, D.M.

    1996-12-31

    The changing competitive environment for the pipeline industry presents a broad spectrum of new challenges and opportunities: international cooperation; globalization of opportunities, organizations and competition; and integrated systems approach to system configuration, financing, contracting strategy, materials sourcing, and operations; cutting edge and emerging technologies; adherence to high standards of environmental protection; an emphasis on safety; innovative approaches to project financing; and advances in technology and programs to maintain the long term, cost effective integrity of operating pipeline systems. These challenges and opportunities are partially a result of the increasingly competitive nature of pipeline development and the public`s intolerance to incidentsmore » of pipeline failure. A creative systems approach to these challenges is often the key to the project moving ahead. This usually encompasses collaboration among users of the pipeline, pipeline owners and operators, international engineering and construction companies, equipment and materials suppliers, in-country engineers and constructors, international lending agencies and financial institutions.« less

  15. A review of drug delivery systems for capsule endoscopy.

    PubMed

    Munoz, Fredy; Alici, Gursel; Li, Weihua

    2014-05-01

    The development of a highly controllable drug delivery system (DDS) for capsule endoscopy has become an important field of research due to its promising applications in therapeutic treatment of diseases in the gastrointestinal (GI) tract and drug absorption studies. Several factors need to be considered to establish the minimum requirements for a functional DDS. Environmental factors of the GI tract and also pharmaceutical factors can help determine the requirements to be met by a DDS in an endoscopic capsule. In order to minimize the influence of such factors on the performance of an effective DDS, at least two mechanisms should be incorporated into a capsule endoscope: an anchoring mechanism to control the capsule position and a drug release mechanism to control variables such as the drug release rate, number of doses and amount of drug released. The implementation of such remotely actuated mechanisms is challenging due to several constraints, including the limited space available in a swallowable capsule endoscope and the delicate and complex environment within the GI tract. This paper presents a comprehensive overview of existing DDS. A comparison of such DDS for capsule endoscopy based on the minimum DDS requirements is presented and future work is also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Magnetically Actuated Soft Capsule With the Multimodal Drug Release Function

    PubMed Central

    Yim, Sehyuk; Goyal, Kartik; Sitti, Metin

    2014-01-01

    In this paper, we present a magnetically actuated multimodal drug release mechanism using a tetherless soft capsule endoscope for the treatment of gastric disease. Because the designed capsule has a drug chamber between both magnetic heads, if it is compressed by the external magnetic field, the capsule could release a drug in a specific position locally. The capsule is designed to release a drug in two modes according to the situation. In the first mode, a small amount of drug is continuously released by a series of pulse type magnetic field (0.01–0.03 T). The experimental results show that the drug release can be controlled by the frequency of the external magnetic pulse. In the second mode, about 800 mm3 of drug is released by the external magnetic field of 0.07 T, which induces a stronger magnetic attraction than the critical force for capsule’s collapsing. As a result, a polymeric coating is formed around the capsule. The coated area is dependent on the drug viscosity. This paper presents simulations and various experiments to evaluate the magnetically actuated multimodal drug release capability. The proposed soft capsules could be used as minimally invasive tetherless medical devices with therapeutic capability for the next generation capsule endoscopy. PMID:25378896

  17. Pneumatic processes in the temporal bone of chimpanzee (Pan troglodytes) and gorilla (Gorilla gorilla).

    PubMed

    Sherwood, R J

    1999-08-01

    The ontogeny of human temporal bone pneumatization has been well studied from both comparative and clinical perspectives. While a difference in the extent of air cell distribution has been noted in our closest living relatives, chimpanzees and gorillas, the processes responsible have been relatively unexplored. To examine these processes, a large, age-graded series of hominoid skulls was radiographed and the progress of pneumatization recorded. Additionally, a subsample of 30 chimpanzees and 12 gorillas was subjected to high-resolution CT scanning. Neonatal specimens show a well-developed mastoid antrum, as well as a capacious hypotympanum extending into the petrous apex. In African apes, as in humans, the mastoid antrum serves as the focus for air cell expansion into the mastoid and immediately adjacent areas. In chimpanzees and gorillas, however, a pronounced lateral structure, described as the squamous antrum, serves as the focus of pneumatization for anterior structures such as the squamous and zygomatic. The diminution of this structure in Homo sapiens explains the difference in air cell distribution in these regions. Copyright 1999 Wiley-Liss, Inc.

  18. Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.

    PubMed

    Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio

    2011-08-02

    Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.

  19. The Very Large Array Data Processing Pipeline

    NASA Astrophysics Data System (ADS)

    Kent, Brian R.; Masters, Joseph S.; Chandler, Claire J.; Davis, Lindsey E.; Kern, Jeffrey S.; Ott, Juergen; Schinzel, Frank K.; Medlin, Drew; Muders, Dirk; Williams, Stewart; Geers, Vincent C.; Momjian, Emmanuel; Butler, Bryan J.; Nakazato, Takeshi; Sugimoto, Kanako

    2018-01-01

    We present the VLA Pipeline, software that is part of the larger pipeline processing framework used for the Karl G. Jansky Very Large Array (VLA), and Atacama Large Millimeter/sub-millimeter Array (ALMA) for both interferometric and single dish observations.Through a collection of base code jointly used by the VLA and ALMA, the pipeline builds a hierarchy of classes to execute individual atomic pipeline tasks within the Common Astronomy Software Applications (CASA) package. Each pipeline task contains heuristics designed by the team to actively decide the best processing path and execution parameters for calibration and imaging. The pipeline code is developed and written in Python and uses a "context" structure for tracking the heuristic decisions and processing results. The pipeline "weblog" acts as the user interface in verifying the quality assurance of each calibration and imaging stage. The majority of VLA scheduling blocks above 1 GHz are now processed with the standard continuum recipe of the pipeline and offer a calibrated measurement set as a basic data product to observatory users. In addition, the pipeline is used for processing data from the VLA Sky Survey (VLASS), a seven year community-driven endeavor started in September 2017 to survey the entire sky down to a declination of -40 degrees at S-band (2-4 GHz). This 5500 hour next-generation large radio survey will explore the time and spectral domains, relying on pipeline processing to generate calibrated measurement sets, polarimetry, and imaging data products that are available to the astronomical community with no proprietary period. Here we present an overview of the pipeline design philosophy, heuristics, and calibration and imaging results produced by the pipeline. Future development will include the testing of spectral line recipes, low signal-to-noise heuristics, and serving as a testing platform for science ready data products.The pipeline is developed as part of the CASA software package by an

  20. Description and Nomenclature of Neisseria meningitidis Capsule Locus

    PubMed Central

    Claus, Heike; Jiang, Ying; Bennett, Julia S.; Bratcher, Holly B.; Jolley, Keith A.; Corton, Craig; Care, Rory; Poolman, Jan T.; Zollinger, Wendell D.; Frasch, Carl E.; Stephens, David S.; Feavers, Ian; Frosch, Matthias; Parkhill, Julian; Vogel, Ulrich; Quail, Michael A.; Bentley, Stephen D.; Maiden, Martin C.J.

    2013-01-01

    Pathogenic Neisseria meningitidis isolates contain a polysaccharide capsule that is the main virulence determinant for this bacterium. Thirteen capsular polysaccharides have been described, and nuclear magnetic resonance spectroscopy has enabled determination of the structure of capsular polysaccharides responsible for serogroup specificity. Molecular mechanisms involved in N. meningitidis capsule biosynthesis have also been identified, and genes involved in this process and in cell surface translocation are clustered at a single chromosomal locus termed cps. The use of multiple names for some of the genes involved in capsule synthesis, combined with the need for rapid diagnosis of serogroups commonly associated with invasive meningococcal disease, prompted a requirement for a consistent approach to the nomenclature of capsule genes. In this report, a comprehensive description of all N. meningitidis serogroups is provided, along with a proposed nomenclature, which was presented at the 2012 XVIIIth International Pathogenic Neisseria Conference. PMID:23628376

  1. Improved coal-slurry pipeline

    NASA Technical Reports Server (NTRS)

    Dowler, W. L.

    1979-01-01

    High strength steel pipeline carries hot mixture of powdered coal and coal derived oil to electric-power-generating station. Slurry is processed along way to remove sulfur, ash, and nitrogen and to recycle part of oil. System eliminates hazards and limitations associated with anticipated coal/water-slurry pipelines.

  2. drPACS: A Simple UNIX Execution Pipeline

    NASA Astrophysics Data System (ADS)

    Teuben, P.

    2011-07-01

    We describe a very simple yet flexible and effective pipeliner for UNIX commands. It creates a Makefile to define a set of serially dependent commands. The commands in the pipeline share a common set of parameters by which they can communicate. Commands must follow a simple convention to retrieve and store parameters. Pipeline parameters can optionally be made persistent across multiple runs of the pipeline. Tools were added to simplify running a large series of pipelines, which can then also be run in parallel.

  3. Genetic algorithm based active vibration control for a moving flexible smart beam driven by a pneumatic rod cylinder

    NASA Astrophysics Data System (ADS)

    Qiu, Zhi-cheng; Shi, Ming-li; Wang, Bin; Xie, Zhuo-wei

    2012-05-01

    A rod cylinder based pneumatic driving scheme is proposed to suppress the vibration of a flexible smart beam. Pulse code modulation (PCM) method is employed to control the motion of the cylinder's piston rod for simultaneous positioning and vibration suppression. Firstly, the system dynamics model is derived using Hamilton principle. Its standard state-space representation is obtained for characteristic analysis, controller design, and simulation. Secondly, a genetic algorithm (GA) is applied to optimize and tune the control gain parameters adaptively based on the specific performance index. Numerical simulations are performed on the pneumatic driving elastic beam system, using the established model and controller with tuned gains by GA optimization process. Finally, an experimental setup for the flexible beam driven by a pneumatic rod cylinder is constructed. Experiments for suppressing vibrations of the flexible beam are conducted. Theoretical analysis, numerical simulation and experimental results demonstrate that the proposed pneumatic drive scheme and the adopted control algorithms are feasible. The large amplitude vibration of the first bending mode can be suppressed effectively.

  4. Apparatus, system, and method for providing fabric-elastomer composites as pneumatic actuators

    DOEpatents

    Martinez, Ramses V.; Whitesides, George M.

    2017-10-25

    Soft pneumatic actuators based on composites consisting of elastomers with embedded sheet or fiber structures (e.g., paper or fabric) that are flexible but not extensible are described. On pneumatic inflation, these actuators move anisotropically, based on the motions accessible by their composite structures. They are inexpensive, simple to fabricate, light in weight, and easy to actuate. This class of structure is versatile: the same principles of design lead to actuators that respond to pressurization with a wide range of motions (bending, extension, contraction, twisting, and others). Paper, when used to introduce anisotropy into elastomers, can be readily folded into three-dimensional structures following the principles of origami; these folded structures increase the stiffness and anisotropy of the elastomeric actuators, while keeping them light in weight.

  5. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  6. Residual mercury content and leaching of mercury and silver from used amalgam capsules.

    PubMed

    Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R

    2002-06-01

    The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.

  7. A comparative study on liquid core formulation on the diameter on the alginate capsules

    NASA Astrophysics Data System (ADS)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  8. [Exploring the clinical characters of Shugan Jieyu capsule through text mining].

    PubMed

    Pu, Zheng-Ping; Xia, Jiang-Ming; Xie, Wei; He, Jin-Cai

    2017-09-01

    The study was main to explore the clinical characters of Shugan Jieyu capsule through text mining. The data sets of Shugan Jieyu capsule were downloaded from CMCC database by the method of literature retrieved from May 2009 to Jan 2016. Rules of Chinese medical patterns, diseases, symptoms and combination treatment were mined out by data slicing algorithm, and they were demonstrated in frequency tables and two dimension based network. Then totally 190 literature were recruited. The outcomess suggested that SC was most frequently correlated with liver Qi stagnation. Primary depression, depression due to brain disease, concomitant depression followed by physical diseases, concomitant depression followed by schizophrenia and functional dyspepsia were main diseases treated by Shugan Jieyu capsule. Symptoms like low mood, psychic anxiety, somatic anxiety and dysfunction of automatic nerve were mainy relieved bv Shugan Jieyu capsule.For combination treatment. Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. The research suggested that syndrome types and mining results of Shugan Jieyu capsule were almost the same as its instructions. Syndrome of malnutrition of heart spirit was the potential Chinese medical pattern of Shugan Jieyu capsule. Primary comorbid anxiety and depression, concomitant comorbid anxiety and depression followed by physical diseases, and postpartum depression were potential diseases treated by Shugan Jieyu capsule.For combination treatment, Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. Copyright© by the Chinese Pharmaceutical Association.

  9. The double capsules in macro-textured breast implants.

    PubMed

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Acoustic system for communication in pipelines

    DOEpatents

    Martin, II, Louis Peter; Cooper, John F [Oakland, CA

    2008-09-09

    A system for communication in a pipe, or pipeline, or network of pipes containing a fluid. The system includes an encoding and transmitting sub-system connected to the pipe, or pipeline, or network of pipes that transmits a signal in the frequency range of 3-100 kHz into the pipe, or pipeline, or network of pipes containing a fluid, and a receiver and processor sub-system connected to the pipe, or pipeline, or network of pipes containing a fluid that receives said signal and uses said signal for a desired application.

  11. Versatile Loading of Diverse Cargo into Functional Polymer Capsules.

    PubMed

    Richardson, Joseph J; Maina, James W; Ejima, Hirotaka; Hu, Ming; Guo, Junling; Choy, Mei Y; Gunawan, Sylvia T; Lybaert, Lien; Hagemeyer, Christoph E; De Geest, Bruno G; Caruso, Frank

    2015-02-01

    Polymer microcapsules are of particular interest for applications including self-healing coatings, catalysis, bioreactions, sensing, and drug delivery. The primary way that polymer capsules can exhibit functionality relevant to these diverse fields is through the incorporation of functional cargo in the capsule cavity or wall. Diverse functional and therapeutic cargo can be loaded into polymer capsules with ease using polymer-stabilized calcium carbonate (CaCO 3 ) particles. A variety of examples are demonstrated, including 15 types of cargo, yielding a toolbox with effectively 500+ variations. This process uses no harsh reagents and can take less than 30 min to prepare, load, coat, and form the hollow capsules. For these reasons, it is expected that the technique will play a crucial role across scientific studies in numerous fields.

  12. Deformation of an elastic capsule in a uniform electric field

    NASA Astrophysics Data System (ADS)

    Karyappa, Rahul B.; Deshmukh, Shivraj. D.; Thaokar, Rochish. M.

    2014-12-01

    The deformation of a thin elastic capsule subjected to a uniform electric field is investigated in the Stokes flow regime. The electrohydrodynamic flow is analyzed using a perfect conductor and a perfect dielectric model for the capsule and the fluid phase, respectively. A theoretical analysis is carried out using an asymptotic expansion in the electric capillary number (Ca) (a ratio of the electric stress to the elastic tension) in the small deformation limit using the finite deformation Hooke's law. The analysis is used to determine the elasticity of polysiloxane capsules suspended in oil, the deformation of which is obtained using videography. The boundary element method is implemented to seek numerical solutions to the hydrodynamic, elastic, and electrostatics equations. The finite deformation Hooke's law, the Mooney-Rivlin, and Skalak's model for elasticity are employed. The effect of electric capillary number, unstressed geometry, and the type of membrane material on the deformation of a capsule is presented in the high Ca number limit using numerical simulation. Capsules synthesized with higher monomer concentration displayed electric stress induced wrinkling process at high electric field strengths. Burst of a capsule is characterized by poration of the polymer membrane, which could be symmetric or asymmetric at the two poles, depending upon the value of the capillary number. The results should be useful in understanding the response of elastic capsules such as red blood cells and polymerized membranes, to an electric field, in applications such as electrodeformation and electroporation. It also provides a theoretical framework for a possible way of determining the elastic parameters of a capsule.

  13. Magnetic pipeline for coal and oil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knolle, E.

    1998-07-01

    A 1994 analysis of the recorded costs of the Alaska oil pipeline, in a paper entitled Maglev Crude Oil Pipeline, (NASA CP-3247 pp. 671--684) concluded that, had the Knolle Magnetrans pipeline technology been available and used, some $10 million per day in transportation costs could have been saved over the 20 years of the Alaska oil pipeline's existence. This over 800 mile long pipeline requires about 500 horsepower per mile in pumping power, which together with the cost of the pipeline's capital investment consumes about one-third of the energy value of the pumped oil. This does not include the costmore » of getting the oil out of the ground. The reason maglev technology performs superior to conventional pipelines is because by magnetically levitating the oil into contact-free suspense, there is no drag-causing adhesion. In addition, by using permanent magnets in repulsion, suspension is achieved without using energy. Also, the pumped oil's adhesion to the inside of pipes limits its speed. In the case of the Alaska pipeline the speed is limited to about 7 miles per hour, which, with its 48-inch pipe diameter and 1200 psi pressure, pumps about 2 million barrels per day. The maglev system, as developed by Knolle Magnetrans, would transport oil in magnetically suspended sealed containers and, thus free of adhesion, at speeds 10 to 20 times faster. Furthermore, the diameter of the levitated containers can be made smaller with the same capacity, which makes the construction of the maglev system light and inexpensive. There are similar advantages when using maglev technology to transport coal. Also, a maglev system has advantages over railroads in mountainous regions where coal is primarily mined. A maglev pipeline can travel, all-year and all weather, in a straight line to the end-user, whereas railroads have difficult circuitous routes. In contrast, a maglev pipeline can climb over steep hills without much difficulty.« less

  14. Comprehensive investigation into historical pipeline construction costs and engineering economic analysis of Alaska in-state gas pipeline

    NASA Astrophysics Data System (ADS)

    Rui, Zhenhua

    This study analyzes historical cost data of 412 pipelines and 220 compressor stations. On the basis of this analysis, the study also evaluates the feasibility of an Alaska in-state gas pipeline using Monte Carlo simulation techniques. Analysis of pipeline construction costs shows that component costs, shares of cost components, and learning rates for material and labor costs vary by diameter, length, volume, year, and location. Overall average learning rates for pipeline material and labor costs are 6.1% and 12.4%, respectively. Overall average cost shares for pipeline material, labor, miscellaneous, and right of way (ROW) are 31%, 40%, 23%, and 7%, respectively. Regression models are developed to estimate pipeline component costs for different lengths, cross-sectional areas, and locations. An analysis of inaccuracy in pipeline cost estimation demonstrates that the cost estimation of pipeline cost components is biased except for in the case of total costs. Overall overrun rates for pipeline material, labor, miscellaneous, ROW, and total costs are 4.9%, 22.4%, -0.9%, 9.1%, and 6.5%, respectively, and project size, capacity, diameter, location, and year of completion have different degrees of impacts on cost overruns of pipeline cost components. Analysis of compressor station costs shows that component costs, shares of cost components, and learning rates for material and labor costs vary in terms of capacity, year, and location. Average learning rates for compressor station material and labor costs are 12.1% and 7.48%, respectively. Overall average cost shares of material, labor, miscellaneous, and ROW are 50.6%, 27.2%, 21.5%, and 0.8%, respectively. Regression models are developed to estimate compressor station component costs in different capacities and locations. An investigation into inaccuracies in compressor station cost estimation demonstrates that the cost estimation for compressor stations is biased except for in the case of material costs. Overall average

  15. Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding.

    PubMed

    Redondo-Cerezo, Eduardo; Sánchez-Capilla, Antonio Damián; De La Torre-Rubio, Paloma; De Teresa, Javier

    2014-11-14

    Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.

  16. Method of forming capsules containing a precise amount of material

    DOEpatents

    Grossman, Mark W.; George, William A.; Maya, Jakob

    1986-01-01

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations therealong and thus enable separation of the tube into said capsules.

  17. Method of forming capsules containing a precise amount of material

    DOEpatents

    Grossman, M.W.; George, W.A.; Maya, J.

    1986-06-24

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations there along and thus enable separation of the tube into said capsules. 7 figs.

  18. Supercooling Water in Cylindrical Capsules

    NASA Astrophysics Data System (ADS)

    Guzman, J. J. Milón; Braga, S. L.

    2005-11-01

    An experimental apparatus was developed to investigate the supercooling phenomenon of water inside cylindrical capsules used for a cold storage process. The coolant is a water-alcohol mixture controlled by a constant temperature bath (CTB). Temperatures varying with time are measured inside and outside the capsule. Cylinders with an internal diameter and thickness of 45 and 1.5 mm, respectively, were made from four different materials: acrylic, PVC, brass, and aluminum. The supercooling period of the water and the nucleation temperature were investigated for different coolant temperatures. The supercooling and nucleation probabilities are shown as a function of the coolant temperature for the four different materials.

  19. Power training using pneumatic machines vs. plate-loaded machines to improve muscle power in older adults.

    PubMed

    Balachandran, Anoop T; Gandia, Kristine; Jacobs, Kevin A; Streiner, David L; Eltoukhy, Moataz; Signorile, Joseph F

    2017-11-01

    Power training has been shown to be more effective than conventional resistance training for improving physical function in older adults; however, most trials have used pneumatic machines during training. Considering that the general public typically has access to plate-loaded machines, the effectiveness and safety of power training using plate-loaded machines compared to pneumatic machines is an important consideration. The purpose of this investigation was to compare the effects of high-velocity training using pneumatic machines (Pn) versus standard plate-loaded machines (PL). Independently-living older adults, 60years or older were randomized into two groups: pneumatic machine (Pn, n=19) and plate-loaded machine (PL, n=17). After 12weeks of high-velocity training twice per week, groups were analyzed using an intention-to-treat approach. Primary outcomes were lower body power measured using a linear transducer and upper body power using medicine ball throw. Secondary outcomes included lower and upper body muscle muscle strength, the Physical Performance Battery (PPB), gallon jug test, the timed up-and-go test, and self-reported function using the Patient Reported Outcomes Measurement Information System (PROMIS) and an online video questionnaire. Outcome assessors were blinded to group membership. Lower body power significantly improved in both groups (Pn: 19%, PL: 31%), with no significant difference between the groups (Cohen's d=0.4, 95% CI (-1.1, 0.3)). Upper body power significantly improved only in the PL group, but showed no significant difference between the groups (Pn: 3%, PL: 6%). For balance, there was a significant difference between the groups favoring the Pn group (d=0.7, 95% CI (0.1, 1.4)); however, there were no statistically significant differences between groups for PPB, gallon jug transfer, muscle muscle strength, timed up-and-go or self-reported function. No serious adverse events were reported in either of the groups. Pneumatic and plate

  20. Active multilayered capsules for in vivo bone formation

    PubMed Central

    Facca, S.; Cortez, C.; Mendoza-Palomares, C.; Messadeq, N.; Dierich, A.; Johnston, A. P. R.; Mainard, D.; Voegel, J.-C.; Caruso, F.; Benkirane-Jessel, N.

    2010-01-01

    Interest in the development of new sources of transplantable materials for the treatment of injury or disease has led to the convergence of tissue engineering with stem cell technology. Bone and joint disorders are expected to benefit from this new technology because of the low self-regenerating capacity of bone matrix secreting cells. Herein, the differentiation of stem cells to bone cells using active multilayered capsules is presented. The capsules are composed of poly-L-glutamic acid and poly-L-lysine with active growth factors embedded into the multilayered film. The bone induction from these active capsules incubated with embryonic stem cells was demonstrated in vitro. Herein, we report the unique demonstration of a multilayered capsule-based delivery system for inducing bone formation in vivo. This strategy is an alternative approach for in vivo bone formation. Strategies using simple chemistry to control complex biological processes would be particularly powerful, as they make production of therapeutic materials simpler and more easily controlled. PMID:20160118

  1. Video-based measurements for wireless capsule endoscope tracking

    NASA Astrophysics Data System (ADS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  2. Dust drift reduction effect of an air conveyor kit (dual-pipe deflector) mounted on different maize pneumatic drills.

    PubMed

    Manzone, Marco; Balsari, Paolo; Marucco, Paolo; Tamagnone, Mario

    2017-03-01

    All maize drills produce a fine dust due to the seed coating abrasions that occur inside the seeding element. The air stream generated by the fan of pneumatic drills - necessary to create a depression in the sowing element of the machine and to guarantee correct seed deposition - can blow away the solid particles detached from the seeds. In order to reduce this phenomenon, a coated maize seeds company (Syngenta®) has set up an ad hoc dual-pipe deflector kit that easily fits different pneumatic drills (also old drills). In this study, the efficiency of this kit and the influence of different drill types on the kit's performance in reducing environmental pollution were evaluated using three different pneumatic seed drill models. The research showed that a dual-pipe deflector installed on a drill in standard configuration did not change the seeder performance, and by using this kit on pneumatic drills, irrespective of their design, it is possible to reduce by up to 69% the amount of dust drift in comparison with the conventional machine set-up. The dual-pipe deflector, under the conditions employed in the present experiments, showed good performance with all types of maize pneumatic drill used. Irrespective of the seeder model on which it is mounted, it is able to obtain similar results, indicating its high operational versatility. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  3. Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.

    PubMed

    Mapara, Sanyat S; Patravale, Vandana B

    2017-09-10

    The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been

  4. Phenotypic Heterogeneity in Expression of the K1 Polysaccharide Capsule of Uropathogenic Escherichia coli and Downregulation of the Capsule Genes during Growth in Urine.

    PubMed

    King, Jane E; Aal Owaif, Hasan A; Jia, Jia; Roberts, Ian S

    2015-07-01

    Uropathogenic Escherichia coli (UPEC) is the major causative agent of uncomplicated urinary tract infections (UTI). The K1 capsule on the surface of UPEC strains is a key virulence factor, and its expression may be important in the onset and progression of UTI. In order to understand capsule expression in more detail, we analyzed its expression in the UPEC strain UTI89 during growth in rich medium (LB medium) and urine and during infection of a bladder epithelial cell line. Comparison of capsule gene transcription using a chromosomal gfp reporter fusion showed a significant reduction in transcription during growth in urine compared to that during growth in LB medium. When examined at the single-cell level, following growth in both media, capsule gene expression appears to be heterogeneous, with two distinct green fluorescent protein (GFP)-expressing populations. Using anti-K1 antibody, we showed that this heterogeneity in gene expression results in two populations of encapsulated and unencapsulated cells. We demonstrated that the capsule hinders attachment to and invasion of epithelial cells and that the unencapsulated cells within the population preferentially adhere to and invade bladder epithelial cells. We found that once internalized, UTI89 starts to produce capsule to aid in its intracellular survival and spread. We propose that this observed phenotypic diversity in capsule expression is a fitness strategy used by the bacterium to deal with the constantly changing environment of the urinary tract. Copyright © 2015 King et al.

  5. Antiobesity effects of Undaria lipid capsules prepared with scallop phospholipids.

    PubMed

    Okada, Tomoko; Mizuno, Yasuyuki; Sibayama, Shinichi; Hosokawa, Masashi; Miyashita, Kazuo

    2011-01-01

    Based on previous research findings, a capsule was developed containing n-3 polyunsaturated fatty acid rich scallop phospholipids (PLs) with an incorporation of brown seaweed (Undaria pinnatifida) lipids (ULs) containing fucoxanthin. The antiobesity effects of the capsules were evaluated with an animal model using 3-wk-old male KK-A(y) mice. Each group received different combinations of lipid (UL, PL, UL + PL, or UL + PL capsule) either incorporated into the diet or into drinking water. Animals were sacrificed after a 4-wk experimental feeding period, and adipose tissues and organs were dissected and weighed. Blood samples were obtained to determine plasma lipid profiles. Uncoupling protein 1 (UCP1) mRNA expression levels were determined by real-time polymerase chain reaction analysis, and UCP1 expression was determined by western blotting analysis. Treatment with either UL alone or UL + PL (capsule) through drinking water resulted in a significant reduction in body weight, compared to the control group. The total white adipose tissue weight of mice fed the UL + PL capsule in drinking water was significantly reduced. Both UCP1 and UCP1 mRNA expression in epididymal fat from mice fed the capsule were significantly higher than in the control group. These results suggest that incorporation of UL into scallop-derived PL by means of capsulation may lead to an additive increase in the antiobesity properties of these bioactive lipids.

  6. 75 FR 22742 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of New Shipper...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-912] New Pneumatic Off-the-Road... the initiation of a new shipper review of the antidumping duty order on new pneumatic off-the-road... Off-the-Road Tires from the People's Republic of China: Initiation of New Shipper Review, 74 FR 56575...

  7. MarsVac: Pneumatic Sampling System for Planetary Exploration

    NASA Astrophysics Data System (ADS)

    Zacny, K.; Mungas, G.; Chu, P.; Craft, J.; Davis, K.

    2008-12-01

    We are proposing a Mars Sample Return scheme whereby a sample of regolith is acquired directly into a Mars Ascent Vehicle using a pneumatic system. Unlike prior developments that used suction to collect fines, the proposed system uses positive pressure to move the regolith. We envisage 3 pneumatic tubes to be embedded inside the 3 legs of the lander. Upon landing, the legs will burry themselves into the regolith and the tubes will fill up with regolith. With one puff of gas, the regolith can be lifted into a sampling chamber onboard of the Mars Ascent Vehicle. An additional chamber can be opened to acquire atmospheric gas and dust. The entire MSR will require 1) an actuator to open/close sampling chamber and 2) a valve to open gas cylinder. In the most recent study related to lunar excavation and funded under the NASA SBIR program we have shown that it is possible lift over 3000 grams of soil with only 1 gram of gas at 1atm. Tests conducted under Mars atmospheric pressure conditions (5 torr). In September of 2008, we will be performing tests at 1/6thg (Moon) and 1/3g (Mars) to determine mass lifting efficiencies in reduced gravities.

  8. Comparisons of sediment losses from a newly constructed cross-country natural gas pipeline and an existing in-road pipeline

    Treesearch

    Pamela J. Edwards; Bridget M. Harrison; Daniel J. Holz; Karl W.J. Williard; Jon E. Schoonover

    2014-01-01

    Sediment loads were measured for about one year from natural gas pipelines in two studies in north central West Virginia. One study involved a 1-year-old pipeline buried within the bed of a 25-year-old skid road, and the other involved a newly constructed cross-country pipeline. Both pipelines were the same diameter and were installed using similar trenching and...

  9. 77 FR 27279 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-09

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... collections relate to the pipeline integrity management requirements for gas transmission pipeline operators... Management in High Consequence Areas Gas Transmission Pipeline Operators. OMB Control Number: 2137-0610...

  10. 75 FR 53733 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-01

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2010-0246] Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous... liquefied natural gas, hazardous liquid, and gas transmission pipeline systems operated by a company. The...

  11. 77 FR 46155 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-02

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... collections relate to the pipeline integrity management requirements for gas transmission pipeline operators... Management in High Consequence Areas Gas Transmission Pipeline Operators. OMB Control Number: 2137-0610...

  12. Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin

    PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complicationsmore » were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.« less

  13. Water Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    1958-01-01

    Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

  14. Water-Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    McGehee, John R.; Hathaway, Melvin E.; Vaughan, Victor L., Jr.

    1959-01-01

    Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

  15. 78 FR 46560 - Pipeline Safety: Class Location Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-01

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... class location requirements for gas transmission pipelines. Section 5 of the Pipeline Safety, Regulatory... and, with respect to gas transmission pipeline facilities, whether applying IMP requirements to...

  16. 77 FR 15453 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-15

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... information collection titled, ``Gas Pipeline Safety Program Certification and Hazardous Liquid Pipeline... collection request that PHMSA will be submitting to OMB for renewal titled, ``Gas Pipeline Safety Program...

  17. 77 FR 51848 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-27

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... Program for Gas Distribution Pipelines. DATES: Interested persons are invited to submit comments on or.... These regulations require operators of hazardous liquid pipelines and gas pipelines to develop and...

  18. 77 FR 26822 - Pipeline Safety: Verification of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2012-0068] Pipeline Safety: Verification of Records AGENCY: Pipeline and Hazardous Materials... issuing an Advisory Bulletin to remind operators of gas and hazardous liquid pipeline facilities to verify...

  19. 77 FR 74275 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-13

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No.... These regulations require operators of hazardous liquid pipelines and gas pipelines to develop and... control room. Affected Public: Operators of both natural gas and hazardous liquid pipeline systems. Annual...

  20. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    NASA Astrophysics Data System (ADS)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  1. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis

    PubMed Central

    Palimaka, S; Blackhouse, Gord; Goeree, Ron

    2015-01-01

    Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion

  2. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Nancy Porter

    2003-05-01

    The two broad categories of deposited weld metal repair and fiber-reinforced composite repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repairs and for fiber-reinforced composite repair. To date, all of the experimental work pertaining to the evaluation of potential repair methods has focused on fiber-reinforced composite repairs. Hydrostatic testing was also conducted on four pipeline sections with simulated corrosion damage: twomore » with composite liners and two without.« less

  3. Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.

    PubMed

    Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane

    2015-02-15

    Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Position control of an electro-pneumatic system based on PWM technique and FLC.

    PubMed

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Development of a 3D parallel mechanism robot arm with three vertical-axial pneumatic actuators combined with a stereo vision system.

    PubMed

    Chiang, Mao-Hsiung; Lin, Hao-Ting

    2011-01-01

    This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot's end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H(∞) tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to

  6. Development of a 3D Parallel Mechanism Robot Arm with Three Vertical-Axial Pneumatic Actuators Combined with a Stereo Vision System

    PubMed Central

    Chiang, Mao-Hsiung; Lin, Hao-Ting

    2011-01-01

    This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot’s end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H∞ tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to

  7. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.

    PubMed

    Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.

  8. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans

    PubMed Central

    Rathore, Sudarshan S.; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg2+ ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg2+ and Ca2+. Our results on gene expression suggest that, Mg2+ does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg2+ ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans. PMID:27014245

  9. Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.

    PubMed

    KuKanich, Butch; Warner, Matt; Hahn, Kevin

    2017-02-01

    OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.

  10. Pipeline monitoring with unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    Kochetkova, L. I.

    2018-05-01

    Pipeline leakage during transportation of combustible substances leads to explosion and fire thus causing death of people and destruction of production and accommodation facilities. Continuous pipeline monitoring allows identifying leaks in due time and quickly taking measures for their elimination. The paper describes the solution of identification of pipeline leakage using unmanned aerial vehicles. It is recommended to apply the spectral analysis with input RGB signal to identify pipeline damages. The application of multi-zone digital images allows defining potential spill of oil hydrocarbons as well as possible soil pollution. The method of multi-temporal digital images within the visible region makes it possible to define changes in soil morphology for its subsequent analysis. The given solution is cost efficient and reliable thus allowing reducing timing and labor resources in comparison with other methods of pipeline monitoring.

  11. Capsule endoscopy: in search of the ideal image.

    PubMed

    Enns, Robert

    2008-01-01

    Capsule studies can be reviewed by varying rates and speeds; however, the presence of significant debris is frustrating to the reviewer much like the excessive stool that tends to hinder the progress of a colonoscopist. Numerous studies have been published in regards to the advantages of an ideal preparation in the setting of capsule endoscopy. This most recent study by Wei et al. is another study that has demonstrated that a colonic preparation, in this situation, combined with simethicone given just prior to the capsule study results in improved visibility of the mucosa. In theory, this will lead to an improved diagnostic ability to limit excessive reading duration.

  12. 75 FR 73160 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-29

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No...-Related Conditions on Gas, Hazardous Liquid, and Carbon Dioxide Pipelines and Liquefied Natural Gas... Pipelines and Liquefied Natural Gas Facilities.'' The Pipeline Safety Laws (49 U.S.C. 60132) require each...

  13. LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  14. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    PubMed

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  15. Ultrasonic technique for inspection of GPHS capsule girth weld integrity

    NASA Astrophysics Data System (ADS)

    Placr, Arnost

    1993-05-01

    An innovative nondestructive examination (NDE) technique for the inspection of integrity of General Purpose Heat Source (GPHS) capsule girth welds was developed employing a Lamb wave as the mode of the sound propagation. Reliability of the Lamb wave technique was tested on GPHS capsules using plutonium pallet simulators. All ten capsules, which were previously rejected, passed ultrasonic (UT) inspection using the Lamb wave technique.

  16. The history of time for capsule endoscopy.

    PubMed

    Adler, Samuel N

    2017-05-01

    Capsule endoscopy was conceived by inventive minds of good people. In the beginning there was a will to do something for medicine. The idea fomented after a discourse between the talented engineer with his physician friend. It took years to develop the concept. Then excellent engineers created de novo the necessary components to turn the capsule into a viable reality. The story is a tribute to human ingenuity.

  17. Landslide and Land Subsidence Hazards to Pipelines

    USGS Publications Warehouse

    Baum, Rex L.; Galloway, Devin L.; Harp, Edwin L.

    2008-01-01

    Landslides and land subsidence pose serious hazards to pipelines throughout the world. Many existing pipeline corridors and more and more new pipelines cross terrain that is affected by either landslides, land subsidence, or both. Consequently the pipeline industry recognizes a need for increased awareness of methods for identifying and evaluating landslide and subsidence hazard for pipeline corridors. This report was prepared in cooperation with the U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration, and Pipeline Research Council International through a cooperative research and development agreement (CRADA) with DGH Consulting, Inc., to address the need for up-to-date information about current methods to identify and assess these hazards. Chapters in this report (1) describe methods for evaluating landslide hazard on a regional basis, (2) describe the various types of land subsidence hazard in the United States and available methods for identifying and quantifying subsidence, and (3) summarize current methods for investigating individual landslides. In addition to the descriptions, this report provides information about the relative costs, limitations and reliability of various methods.

  18. Solid State Stability of Extemporaneously Prepared Levothyroxine Aliquots and Capsules.

    PubMed

    Fortner, Jeff; Salton, Jason; Carlson, Christie; Wheeler, Rich; Cote, Brianna; Rao, Deepa

    2015-01-01

    The purpose of this research was to collect, analyze, and compare stability data for levothyroxine (T4) powder in the anhydrous and pentahydrate form when prepared as an aliquot and in capsules. Two different compounding pharmacies, Central Iowa Compounding and Gateway Medical Pharmacy, used different forms of T4 and aliquot formulations, which were studied to determine the beyond-use date at ±5% or ±10% of labeled strength. T4 was extracted from aliquot and capsule formulations and assessed using reverse-phase high- performance liquid chromatography validated to differentiate between the degraded and original forms of T4. The results indicate that T4 1:100 aliquot formulation prepared with silica gel or Avicel as filler are stable for 120 days at ±10% labeled potency, but at ±5% labeled potency, the silica gel and Avicel aliquot formulations are stable for 45 and 30 days, respectively. The silica gel capsules prepared from fresh aliquot were stable for 120 days at ±10% labeled potency and 90 days at ±5% labeled potency, while the Avicel capsules prepared from fresh aliquot were stable for 180 days at both ±10% and ±5% labeled potency. Avicel capsules prepared from old aliquot (120 days) and fresh aliquot (1 day) were also compared for stability. The old aliquot Avicel capsules were stable for 14 days at ±5% labeled potency and 150 days at ±10% labeled potency, while new aliquot Avicel capsules were stable for 180 days at both ±10% and ±5% labeled potency. Based on our data, there can be significant variation in the beyond-use dates assigned to T4 capsules based on the diluents used for aliquots, the final capsule formulations, and the potency standards applied. These results also indicate that pharmacists must exercise caution when using older aliquots and may have to assign shorter beyond-use dates.

  19. Safety of capsule endoscopy using human body communication in patients with cardiac devices.

    PubMed

    Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young

    2012-06-01

    The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

  20. 77 FR 10476 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Second...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    ...-the-Road Tires From the People's Republic of China: Notice of Second Extension of Time Limit for the... duty order on certain new pneumatic off-the-road tires (``off-the-road tires'') from the People's... on off- the-road tires from the PRC. See Certain New Pneumatic Off-the-Road Tires from the People's...