Science.gov

Sample records for pneumatic irradiation rabbit

  1. Automated pneumatic transfer irradiation system for delayed neutron counting

    SciTech Connect

    Heifer, Paul G.; Millard, Hugh T. Jr.; Zermane, Albert J

    1982-07-01

    The Geological Survey TRIGA Reactor has been used for uranium and thorium neutron activation analysis by delayed neutron counting for the past eleven years. As the requirements for analysis increased the original General Atomic pneumatic system was upgraded in several stages. By 1979 we had reached the practical limits of safe through-put for that system and a new pneumatic transfer system was built. A single large Roots type blower is used to drive four individual transfer tubes simultaneously (two termini in the core and two outside the reflector). A microprocessor controls the operation and is paced by a minicomputer, which is also used to collect and reduce the counting data. Two irradiations and counting cycles are performed on each sample, one in the core, a Cd-lined terminus for thorium, and one in the reflector mounted terminus for uranium. Video displays at both the reactor console and the pneumatic system operating station indicate the status of the system and the locations of the samples at all times. This highly automated system is capable of 1,200 irradiations for delayed neutron counting in a 10 hour day, and, in addition, incorporates programmable versatility for other irradiation-counting experiments, and provides a high degree of reactor and radiological safety with only remote operator attention. (author)

  2. Pneumatics.

    ERIC Educational Resources Information Center

    Engelbrecht, Nancy; And Others

    This unit on pneumatics, for use in postsecondary programs, is organized in eight sections. Each section consists of information sheets with line drawings and multiple-choice questions for each topic in the sections. Answers are provided at the back of the book. The following topics are covered: (1) introduction--pressure, principles of gases,…

  3. Acute microwave irradiation and cataract formation in rabbits and monkeys.

    PubMed

    Kramar, P; Harris, C; Emery, A F; Guy, A W

    1978-09-01

    Rabbits and monkeys were irradiated in the near field of a cavity-backed 2450 MHz resonant slot radiator, to determine the cataractogenic threshold. Rabbits developed cataracts at incident "apparent" power densities of 180 mW/cm2 (E2/120 pi, where E=rms/electric field strength). Monkeys sustained facial burns, but no lens damage, even at incident "apparent" power densities of 500 mW/cm2. These results were substantiated by computer thermal models. PMID:108401

  4. Phase separation of X-irradiated lenses of rabbit

    SciTech Connect

    Clark, J.I.; Giblin, F.J.; Reddy, V.N.; Benedek, G.B.

    1982-02-01

    The phase separation temperature (Tcat) was studied as a function of time (age) after the administration of a single dose of radiation (2000 rad), which induces cataract in the rabbit lens. In the normal unirradiated lens, Tcat decreases linearly with age at a rate (DTcat/dt) approximately 2.2 degrees/week. In the irradiated lens, Tcat initially decreases with age much less than the normal lens, then rises sharply with age at the time of the appearance of opacity in the living rabbit eye. We suggest that the phase separation temperature may serve as a sensitive and early indicator of cataractogenic processes in the lens.

  5. Late degeneration in rabbit tissues after irradiation by heavy ions

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Keng, P. C.; Lee, A. C.; Su, C. M.; Bergtold, D. S.

    1980-01-01

    Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

  6. Disposal rabbit

    DOEpatents

    Lewis, L.C.; Trammell, D.R.

    1983-10-12

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  7. Disposable rabbit

    DOEpatents

    Lewis, Leroy C.; Trammell, David R.

    1986-01-01

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  8. Gamma-Irradiated Sterile Cornea for Use in Corneal Transplants in a Rabbit Model

    PubMed Central

    Yoshida, Junko; Heflin, Thomas; Zambrano, Andrea; Pan, Qing; Meng, Huan; Wang, Jiangxia; Stark, Walter J.; Daoud, Yassine J.

    2015-01-01

    Purpose: Gamma irradiated corneas in which the donor keratocytes and endothelial cells are eliminated are effective as corneal lamellar and glaucoma patch grafts. In addition, gamma irradiation causes collagen cross inking, which stiffens collagen fibrils. This study evaluated gamma irradiated corneas for use in corneal transplantations in a rabbit model comparing graft clarity, corneal neovascularization, and edema. Methods: Penetrating keratoplasty was performed on rabbits using four types of corneal grafts: Fresh cornea with endothelium, gamma irradiated cornea, cryopreserved cornea, and fresh cornea without endothelium. Slit lamp examination was performed at postoperative week (POW) one, two, and four. Corneal clarity, edema, and vascularization were graded. Confocal microscopy and histopathological evaluation were performed. A P < 0.05 was statistically significant. Results: For all postoperative examinations, the corneal clarity and edema were statistically significantly better in eyes that received fresh cornea with endothelium compared to the other three groups (P < 0.05). At POW 1, gamma irradiated cornea scored better than the cryopreserved and fresh cornea without endothelium groups in clarity (0.9 vs. 1.5 and 2.6, respectively), and edema (0.6 vs. 0.8 and 2.0, respectively). The gamma irradiated corneas, cryopreserved corneas and the fresh corneas without endothelium, developed haze and edema after POW 2. Gamma irradiated cornea remained statistically significantly clearer than cryopreserved and fresh cornea without endothelium during the observation period (P < 0.05). Histopathology indicated an absence of keratocytes in gamma irradiated cornea. Conclusion: Gamma irradiated corneas remained clearer and thinner than the cryopreserved cornea and fresh cornea without endothelium. However, this outcome is transient. Gamma irradiated corneas are useful for lamellar and patch grafts, but cannot be used for penetrating keratoplasty. PMID:26180475

  9. Kinetics of (/sup 14/C-5) 8-methoxypsoralen uptake by UVA irradiated and non-irradiated rabbit eye tissues

    SciTech Connect

    Malinin, G.I.; Glew, W.B.; Roberts, W.P.; Nigra, T.P.

    1981-05-01

    Total 8-methoxypsoralen (8-MOP) in intact and UVA irradiated rabbit eye tissues and its unaltered fraction in aqueous and eye lenses were determined over the 24 hours after i.v. injection of (/sup 14/C-5) and carrier 8-MOP at the concentration of 50 microCi and 5 mg/kg. No 8-MOP was detected at the end of 24 hours in intact and irradiated aqueous, vitreous and retina in contrast to one hour when the respective levels were congruent to 220, greater than 0 and congruent to 160 ng/g. Eye-plasma drug concentration ratios were less than 0.5 initially, but increased thereafter. While the average lens 8-MOP levels of congruent to 140 ng/g remained unchanged for 24 hours, no unaltered drug was detected beyond eight hours. Measurable amounts of label at the end of 24 hours also persisted in the cornea, iris, sclera and conjunctiva.

  10. The hematologic effects of low intensity 650 nm laser irradiation on hypercholesterolemia rabbits

    PubMed Central

    Wang, Hong; Deng, Juan; Tu, Wenjun; Zhang, Lin; Chen, Hongli; Wu, Xiaoguang; Li, Yingxin; Sha, Hong

    2016-01-01

    Purpose: To test the hematologic effects of low intensity 650 nm laser irradiation on hypercholesterolemia rabbits. Methods: Ten male big-eared rabbits were selected from hypercholesterolemia animal model-making and divided into model group and laser treatment groups. Five normal rabbits were selected as control group. Auricle root irradiation of 650 nm laser 100 mW in 30 min were applied on treatment group twice a day, treatment of 6 days in one week, 20 weeks course of treatment. Changes in blood lipid, microcirculation, rheological properties, and aggregation morphology of erythrocytes were observed every two weeks. Histopathological examination were performed in the end of experiments. Results: After 20 weeks’ treatment, triglyceride (TG), cholesterol (CHO), high density lipoprotein (HDL) and low density lipoprotein (LDL) of serum in hypercholesterolemia groups showed less changes in the first 4 weeks, butdifferent decreasing trends were shownin the next 16 weeks’ therapy. Erythrocytes aggregation of model groups showed rouleau state, while red blood cells in control group showed fine homodisperse, erythrocytes in treatment group performed better dispersion than model groups. Erythrocyte deformation index (DI) and blood flow value showed a statistic improvement in treatment group than control and model group (P<0.01). Value of DI in treatment group decreased after 18 weeks than values before therapy (P<0.01). Varying degrees of Aorta plaque formation was observed for individual difference in model and treatment groups, while no plaque was found in control group. Conclusions: Low energy laser improve microcirculation, rheological properties and blood lipid that might be related with erythrocytes aggregation and deformability. PMID:27347336

  11. Effect of helium-neon and infrared laser irradiation on wound healing in rabbits

    SciTech Connect

    Braverman, B.; McCarthy, R.J.; Ivankovich, A.D.; Forde, D.E.; Overfield, M.; Bapna, M.S.

    1989-01-01

    We examined the biostimulating effects of helium-neon laser radiation (HeNe; 632.8 nm), pulsed infrared laser radiation (IR; 904 nm), and the two combined on skin wound healing in New Zealand white rabbits. Seventy-two rabbits received either (1) no exposure, (2) 1.65 J/cm2 HeNe, (3) 8.25 J/cm2 pulsed IR, or (4) both HeNe and IR together to one of two dorsal full-thickness skin wounds, daily, for 21 days. Wound areas were measured photographically at periodic intervals. Tissue samples were analyzed for tensile strength, and histology was done to measure epidermal thickness and cross-sectional collagen area. Significant differences were found in the tensile strength of all laser-treated groups (both the irradiated and nonirradiated lesion) compared to group 1. No differences were found in the rate of wound healing or collagen area. Epidermal growth was greater in the HeNe-lased area compared to unexposed tissue, but the difference was not significant. Thus, laser irradiation at 632.8 nm and 904 nm alone or in combination increased tensile strength during wound healing and may have released tissue factors into the systemic circulation that increased tensile strength on the opposite side as well.

  12. Elemental analysis of Egyptian crude oils by INAA using rabbit irradiation system at ETRR-2 reactor.

    PubMed

    El-Khayatt, A M

    2010-12-01

    Instrumental neutron activation analysis (INAA) using rabbit irradiation system at ETRR-2 reactor was utilized to analyze some elements namely Na, Mg, Al, Cl, V, Mn, In, and Br in four different crude petroleum samples from different oil fields in the Suez-Gulf region of Egypt. The INAA was performed by four different standardization methods. Namely absolute, single comparator based on effective cross section concept, single comparator based on k(0,Au) factors, and that based on k(0,ic) factors defined versus any suitable internal comparator method. A FORTRAN computer program was written to calculate the extracted concentrations by these methods. A reasonable agreement between the obtained results was noticed. PMID:20692177

  13. Effects of low-energy He-Ne laser irradiation on posttraumatic degeneration of adult rabbit optic nerve

    SciTech Connect

    Schwartz, M.; Doron, A.; Erlich, M.; Lavie, V.; Benbasat, S.; Belkin, M.; Rochkind, S.

    1987-01-01

    Axons of the mammalian peripheral and central nervous systems degenerate after nerve injury. We have recently found that He-Ne laser irradiation may prevent some of the consequences of the injury in peripheral nerves of mammals. In the present study, the efficacy of the laser in treating injured neurons of the mammalian CNS was tested. Optic nerves of adult rabbits were exposed daily for 8-14 days to He-Ne laser irradiation (14 min, 15 mW) through the overlying muscles and skin. As a result of this treatment, the injured nerves maintained their histological integrity, which is invariably lost in injured mammalian CNS neurons.

  14. A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

    SciTech Connect

    Cai Jing; Mata, Jaime F.; Orton, Matthew D.; Hagspiel, Klaus D.; Mugler, John P.; Larner, James M.; Sheng Ke; Read, Paul W.

    2009-04-01

    Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

  15. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  16. Differential analysis of D-{beta}-Asp-containing proteins found in normal and infrared irradiated rabbit lens

    SciTech Connect

    Takata, Takumi; Shimo-Oka, Tadashi; Kojima, Masami; Miki, Kunio; Fujii, Noriko . E-mail: nfujii@HL.rri.kyoto-u.ac.jp

    2006-05-26

    Although proteins are generally composed of L-{alpha}-amino acids, D-{beta}-aspartic acid (Asp)-containing proteins have been reported in various elderly tissues. Our previous study detected several D-{beta}-Asp-containing proteins in a rabbit lens derived from epithelial cell line by Western blot analysis of a 2D-gel using a polyclonal antibody that is highly specific for D-{beta}-Asp-containing proteins. The identity of each spot was subsequently determined by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and the Ms-Fit online database searching algorithm. In this study, we discovered novel D-{beta}-Asp-containing proteins from rabbit lens. The results indicate that {beta}-crystallin A3, {beta}-crystallin A4, {beta}-crystallin B1, {beta}-crystallin B2, {beta}-crystallin B3, {gamma}-crystallin C, {gamma}-crystallin D, and {lambda}-crystallin in rabbit lens contain D-{beta}-Asp residues. Furthermore, the occurrence of D-{beta}-Asp residues increases with infrared ray (IR) irradiation. Additionally, some D-{beta}-Asp-containing proteins only appear after IR irradiation. One such protein is the {alpha}-enolase, which shows homology to {tau}-crystallin.

  17. Investigation of carbohydrate and protein metabolism in the digestive organs of the rabbit under the combined influence of vibration, acceleration and irradiation

    NASA Technical Reports Server (NTRS)

    Yuy, R. I.

    1975-01-01

    During spaceflight, the organism is subjected to the influence of various extremal factors such as acceleration, vibration, irradiation, etc. The study of the influence of these factors on metabolism, especially carbohydrate and protein metabolism, in young rabbits is of great significance in simulation experiments. Dynamic factors and irradiation, depending on dose and duration, lead to reduced RNA and protein metabolism.

  18. Effects of low-intensity laser irradiation on the apoptosis of rabbit vascular smooth muscle cells in culture

    NASA Astrophysics Data System (ADS)

    Li, S. D.; Chen, P.; Zhang, C. P.; Wen, J. X.; Liang, J.; Kang, H. X.; Gao, R. L.; Fu, X. B.

    2011-11-01

    Restenosis is a major complication after coronary intervention therapy. Excessive proliferation of vascular smooth muscle cells (VSMCs) and a decline in their apoptosis, which eventually leads to excessive neointimal thickening in coronary arteries, are the main causes of restenosis. Induction of the apoptosis of VSMCs and inhibition of excessive proliferation of VSMCs are therefore crucial for the prevention of restenosis, and low-intensity laser irradiation of coronary arteries may play a promising role in keeping this in balance. In this study, we used in vitro cultured rabbit VSMCs to investigate the effects of low-intensity laser irradiation at a wavelength of 532 nm on the apoptosis of VSMCs via morphological observation and molecular biology. The results showed that apoptotic bodies and obvious intranuclear apoptosis-positive particles formed within VSMCs 24 h after laser irradiation, suggesting that low-intensity laser irradiation at certain doses can inhibit the proliferation of VSMCs by promoting their apoptosis. This experiment provides evidences for further animal experiments and clinical trials on prevention and treatment of restenosis by intracoronary low-intensity laser irradiation at a wavelength of 532 nm.

  19. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  20. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  1. The effect of topical dexamethasone and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit

    SciTech Connect

    Miller, M.H.; Grierson, I.; Unger, W.G.; Hitchings, R.A. )

    1990-01-01

    We studied the effect of topical dexamethasone (1%) and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit. Intraocular pressure and gross facility of aqueous outflow following surgery were not influenced by either treatment, although blebs persisted longer in the irradiated eyes. Steroids reduced clinically observable inflammation as well as the number of inflammatory cells identifiable by microscopy. Fibroblast production temporarily slowed, and ultrastructural examination demonstrated lipid-filled vacuoles and dilated mitochondria in these eyes. Also, the scar was thinner at 24 days. Beta irradiation delayed wound healing and the scar was thinner in the early postoperative stages, but the light microscopic appearance of the scar was unaltered at 59 days. Inflammation was more pronounced initially, with abundant fibrin in the wound. Recovery of the conjunctival epithelium was delayed. The delay in fibroblast recruitment and wound contraction, the thinner scar tissue, and the increased survival of the bleb are all factors that suggest that beta irradiation may be a useful adjunct to glaucoma surgery.

  2. Pneumatically erected rigid habitat

    NASA Technical Reports Server (NTRS)

    Salles, Bradley

    1992-01-01

    The pneumatically erected rigid habitat concept consists of a structure based on an overexpanded metal bellows. The basic concept incorporates the advantages of both inflatable and rigid structures. The design and erection detail are presented with viewgraphs.

  3. High resolution scanning electron microscopy of rabbit corneal endothelium to show effects of UV-visible irradiation in the presence of chlorpromazine

    SciTech Connect

    Lea, P.J.; Hollenberg, M.J.; Menon, I.A.; Temkin, R.J.; Persad, S.D.; Basu, P.K. )

    1989-01-01

    The ultrastructure of rabbit cornea endothelial cells was examined by scanning electron microscopy (SEM) in freeze-cleaved corneas using a Hitachi S-570 scanning electron microscope in the high resolution mode (HRSEM). In order to study phototoxic effects in vitro, rabbit corneas (experimental) were cultured as organ culture in the presence of 5 micrograms/ml chlorpromazine (CPZ) and irradiated. For comparison, control 1 corneas were not irradiated but incubated in the dark without CPZ in the medium; control 2 corneas were also kept in the dark but in the presence of CPZ; control 3 corneas were irradiated with no CPZ in the medium. Cellular damage was not seen in the three types of control corneas, but in the experimental corneas the endothelial cells showed extensive disruption of the cell membrane and some deterioration of the intracellular components. Our study confirmed that HRSEM is a satisfactory new technique for visualizing damage of the intracellular organelles of corneal endothelium.

  4. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    SciTech Connect

    Kawase, Takatsugu; Kunieda, Etsuo Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  5. Improvement of thermal effects to rabbit atherosclerotic aortas by macro pulse irradiation of a quantum cascade laser in the 5.7 μm wavelength range

    NASA Astrophysics Data System (ADS)

    Hashimura, Keisuke; Ishii, Katsunori; Awazu, Kunio

    2015-03-01

    Atherosclerotic plaques mainly consist of cholesteryl esters. Cholesteryl esters have an absorption peak at the wavelength of 5.75 μm originated from C=O stretching vibration mode of ester bond. Our group achieved making cutting difference between atherosclerotic lesions and normal vessels using a quantum cascade laser (QCL) in the 5.7 μm wavelength range. QCLs are relatively new types of semiconductor lasers that can emit mid-infrared range. They are sufficiently compact and have recently achieved their high-power emission. However, large thermal damage was observed because the QCL worked as a quasi-continuous wave laser due to its short pulse interval. To realize less invasive ablation by the QCL, reducing thermal effects to normal vessels is needed. In this study, we tried improving the thermal effects by changing the pulse structure. First, irradiation effects to rabbit atherosclerotic aortas by macro pulse irradiation (irradiation of pulses at intervals) and conventional continuous pulse irradiation were compared. The macro pulse width and the macro pulse interval were set to 0.54 and 12 ms, respectively, because the thermal relaxation time of rabbit normal and atherosclerotic aortas in the oscillation wavelength was 0.54-12 ms. As a result, ablation depth became longer and coagulation width became shorter by the macro pulse irradiation. In addition, cutting difference between rabbit normal and atherosclerotic aortas was observed by the macro pulse irradiation. Therefore, the macro pulse irradiation achieved the improvement of thermal effects by the QCL in the 5.7 μm wavelength range. The QCL has the potential of realizing less-invasive laser angioplasty.

  6. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  7. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  8. Pneumatic sample-transfer system for use with the Lawrence Livermore National Laboratory rotating target neutron source (RTNS-I)

    SciTech Connect

    Williams, R.E.

    1981-07-01

    A pneumatic sample-transfer system is needed to be able to rapidly retrieve samples irradiated with 14-MeV neutrons at the Rotating Target Neutron Source (RTNS-I). The rabbit system, already in place for many years, has been refurbished with modern system components controlled by an LSI-11 minicomputer. Samples can now be counted three seconds after an irradiation. There are many uses for this expanded 14-MeV neutron activation capability. Several fission products difficult to isolate from mixed fission fragments can be produced instead through (n,p) or (n,..cap alpha..) reactions with stable isotopes. Mass-separated samples of Nd, Mo, and Se, for example, can be irradiated to produce Pr, Nb, and As radionuclides sufficient for decay scheme studies. The system may also be used for multielement fast-neutron activation analysis because the neutron flux is greater than 2 x 10/sup 11/ n/cm/sup 2/-sec. Single element analyses of Si and O are also possible. Finally, measurements of fast-neutron cross sections producing short-lived activation products can be performed with this system. A description of the rabbit system and instructions for its use are presented in this report.

  9. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  10. Ultraviolet-irradiated vaccinia virus recombinants, exposing HIV-envelope on their outer membrane, induce antibodies against this antigen in rabbits.

    PubMed

    Loewinger, M; Katz, E

    2002-01-01

    The construction and isolation of recombinants of vaccinia virus (IHD-J strain), bearing on their outer membrane a chimeric protein consisting of the cytoplasmic and transmembrane domains of vaccinia B5R protein and the external domain of HIV envelope, has been previously described by us. The present study aimed to investigate the potential use of such recombinants as a vaccine, following inactivation of their infectivity by ultraviolet (UV) irradiation. The minimal dose of UV irradiation, required for the complete inactivation of the infectivity of these recombinants, was determined. Injections of rabbits with the irradiated noninfectious recombinant viruses successfully induced specific antibodies against the HIV envelope antigen, in addition to those against the poxvirus. PMID:12479396

  11. The influence of intravenous laser irradiation of blood on some metabolic and functional parameters in intact rabbits and experimental cerebral ischaemia

    NASA Astrophysics Data System (ADS)

    Nechipurenko, N.; Vasilevskaya, L.; Musienko, J.; Maslova, G.

    2007-07-01

    It has been studied the intravenous laser irradiation of blood (ILIB) influence with helium-neon laser (HNL) of 630 nm wavelength on some of lipid peroxidation (LPO) and antioxidant system (AOS) findings, aside-base status (ABS) and blood oxygen transport (BOT), state of dermal microhaemodynamics (MGD) in the intact rabbits and after modeling of local ischemia of brain (LIB). Depending on conditions of organism functioning (norm or brain ischaemia) ILIB has resulted in stimulating or normalizing effects on the whole metabolic and microhaemocirculation processes which had been studied during our investigation. It is discussed the mechanisms of pathogenetic directivity of ILIB influence in cerebral ischaemia

  12. Pneumatization of the sphenoid sinus.

    PubMed

    Terra, E R; Guedes, F R; Manzi, F R; Bóscolo, F N

    2006-01-01

    This paper describes a case of pneumatization of the sphenoid sinus in the pterygoid process and greater wing of the sphenoid bone, observed on a panoramic radiograph. Conventional radiographs and computerized tomography in axial and coronal sections confirmed the presence of the pneumatization of these structures. PMID:16421265

  13. Pneumatic Pellet-Transporting System

    NASA Technical Reports Server (NTRS)

    Wood, George; Pugsley, Robert A.

    1992-01-01

    Pneumatic system transports food pellets to confined animals. Flow of air into venturi assembly entrains round pellets, drawing them from reservoir into venturi for transport by airflow. Pneumatic pellet-transporting system includes venturi assembly, which creates flow of air that draws pellets into system.

  14. The complication of pneumatic retinopexy.

    PubMed Central

    Hilton, G F; Tornambe, P E; Brinton, D A; Flood, T P; Green, S; Grizzard, W S; Hammer, M E; Leff, S R; Mascuilli, L; Morgan, C M

    1990-01-01

    There have been 26 published series with a total of 1274 detachments operated with pneumatic retinopexy. Eighty percent were reattached with a single procedure and 98% with reoperations. New breaks occurred in 13% and PVR in 4%. The complications published in 101 papers on pneumatic retinopexy in the last 5 years are analyzed as to frequency, prevention, management, and results. PMID:2095021

  15. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays.

    PubMed

    el-Mofty, M M; Sakr, S A; Younis, M W

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin. PMID:2794550

  16. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays

    SciTech Connect

    el-Mofty, M.M.; Sakr, S.A.; Younis, M.W. )

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin.

  17. Mucosal injury and. gamma. -irradiation produce persistent gastric ulcers in the rabbit. Evaluation of antiulcer drug binding to experimental ulcer sites

    SciTech Connect

    Yokel, R.A.; Dickey, K.M. )

    1991-05-01

    A method producing persistent gastric ulcers in the rhesus monkey by combined mucosal injury and {gamma}-irradiation was modified and evaluated in the rabbit. {gamma}-Irradiation (800-1000 cGy) immediately after removal of 2-mm-diameter sections of antral mucosa resulted in ulcer craters 5-7 days later. Ulcer sites were characterized by loss of the mucosa, muscularis mucosa, and much of the submucosa. The exposed submucosa was coated with fibrin and necrotic debris infiltrated with heterophils, the rabbit equivalent of neutrophils. These ulcers strongly resemble human chronic gastric ulcers. Binding of Carafate (sucralfate; Marion Laboratories, Inc., Kansas City, MO) and Maalox (magnesia-alumina oral suspension; Wm. H. Rorer, Inc., Ft. Washington, PA) to ulcer and nearby nonulcer sites in the antrum was assessed 1 hour after drug dosing. Drug binding was determined by aluminum quantitation of stomach wall punch biopsies at necropsy. Both drugs significantly increased aluminum bound to the stomach wall compared with vehicle treatment. Significantly more antiulcer drug was bound to ulcer sites than to nearby nonulcer sites only after sucralfate administration. This model of persistent gastric ulcer should be useful to further study gastric ulcer pathogenesis and treatment.

  18. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A mechanized technique to seal abandoned mines has been used successfully to close 13 openings at Duquesne Light Co.'s mined-out Warwick No. 2 mine, near Greensboro, Pa. The mechanized system, which uses a pneumatic stower and crushed limestone, closed the entries more economically and in less time than it would have taken to install traditional concrete block stopping and clay plug seals, according to John C. Draper. Draper, a mining engineer with Duquesne Light's coal department, was in charge of installing the Warwick seals in a Bureau of Mines-sponsored field test on the pneumatic sealing technique. The lowest estimated cost for installing conventional stopping and plug closures for the 13 Warwick openings was $225,000, says Draper, while the openings were closed using the mechanized system for $245,000. Draper says the newer stopping cost more in the instance because work was stopped often to gather information for the experiment. The experimental closures were installed in 38 days. The job would have taken at least 149 days if traditional closures were being installed, Draper say. To install a traditional concrete block/clay plug closure, the mine opening must be cleaned thoroughly and the roof must be supported for some 3 ft from the outside. Then a solid wall or stopping must be built 25 ft from the surface and the entry must be packed with clay to the surface. Much of this job requires workers to remain underground. In pneumatic stowing, 1 1/2-in. crushed limestone with fines is conveyed through a pipeline and into the mine opening under low air pressure. Watertight seals can be installed by blowing about 10 ft of rock into the opening against the top to act as roof support. Safety posts are installed and about 10 or 15 ft of mine entry is cleaned. About 2 in. of raw cement or bentonite is placed on the floor and limestone mixed with dry cement or bentonite is blown into the opening.

  19. PNEUMATIC PUMPING TEST FOR SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. etermination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. ressure propaga...

  20. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  1. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  2. The Anti-calcification Effect of Dithiobispropionimidate, Carbodiimide and Ultraviolet Irradiation Cross-linking Compared to Glutaraldehyde in Rabbit Implantation Models

    PubMed Central

    Park, Samina; Kim, Soo Hwan; Lim, Hong-Gook; Lim, Cheong

    2013-01-01

    Background Glutaraldehyde (GA) is a widely used cross-linking agent for improving mechanical properties and resistance to enzymatic degradation of collagenous tissue, but it has several drawbacks such as calcification and cytotoxicity. The aim of this study was to find the alternative effective cross-linking methods to GA. Materials and Methods Bovine pericardium was processed with GA with ethanol+octanol and glycine detoxification, and polyethylene glycol (PG) space filler, dimethyl 3,3'-dithiobispropionimidate (DTBP), 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) treatment, and the physical fixation of ultraviolet irradiation were done. The biologic material properties of variously treated pericardial tissues were assessed by biochemical, mechanical and histological tests. Treated pericardial tissues were also implanted subcutaneously or intramuscularly into the rabbit for 10 weeks to assess the xenoreactive antibody response of immunoglobulin G and M, their anti-calcification effect. Results The biochemical and mechanical properties of EDC fixed pericardial tissues were comparable to the GA fixed tissue. The cytotoxicity was lowest in space filler treated GA fixed group. In rabbit subcutaneous or intramuscular implantation models, decellularization, space filler, EDC treatment group showed significantly lower calcium content than GA only and DTBP treatment group (p<0.05, analysis of variance). The titer of anti Galα1-3Galβ1-4GlcNAc-R antibodies did not change in the postimplantation serial enzyme-linked immunosorbent assay. Hematoxylin and eosin and von Kossa staining showed that decellularization, space filler, EDC, and ultraviolet treatment had less inflammatory cell infiltration and calcium deposits. Conclusion The decellularization process, PG filler, and EDC treatments are good alternative cross-linking methods compared to GA only fixation and primary amine of DTBP treatment for cardiovascular xenograft preservation in terms of the collagen cross

  3. Pneumatic Spoiler Controls Airfoil Lift

    NASA Technical Reports Server (NTRS)

    Hunter, D.; Krauss, T.

    1991-01-01

    Air ejection from leading edge of airfoil used for controlled decrease of lift. Pneumatic-spoiler principle developed for equalizing lift on helicopter rotor blades. Also used to enhance aerodynamic control of short-fuselage or rudderless aircraft such as "flying-wing" airplanes. Leading-edge injection increases maneuverability of such high-performance fixed-wing aircraft as fighters.

  4. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  5. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  6. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    NASA Astrophysics Data System (ADS)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  7. Sliding pressure control valve for pneumatic hammer drill

    SciTech Connect

    Polsky, Yarom

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  8. Automatic irradiation control by an optical feedback technique for selective retina treatment (SRT) in a rabbit model

    NASA Astrophysics Data System (ADS)

    Seifert, Eric; Roh, Young-Jung; Fritz, Andreas; Park, Young Gun; Kang, Seungbum; Theisen-Kunde, Dirk; Brinkmann, Ralf

    2013-06-01

    Selective Retina Therapy (SRT) targets the Retinal Pigment Epithelium (RPE) without effecting neighboring layers as the photoreceptors or the choroid. SRT related RPE defects are ophthalmoscopically invisible. Owing to this invisibility and the variation of the threshold radiant exposure for RPE damage the treating physician does not know whether the treatment was successful or not. Thus measurement techniques enabling a correct dosing are a demanded element in SRT devices. The acquired signal can be used for monitoring or automatic irradiation control. Existing monitoring techniques are based on the detection of micro-bubbles. These bubbles are the origin of RPE cell damage for pulse durations in the ns and μs time regime 5μs. The detection can be performed by optical or acoustical approaches. Monitoring based on an acoustical approach has already been used to study the beneficial effects of SRT on diabetic macula edema and central serous retinopathy. We have developed a first real time feedback technique able to detect micro-bubble induced characteristics in the backscattered laser light fast enough to cease the laser irradiation within a burst. Therefore the laser energy within a burst of at most 30 pulses is increased linearly with every pulse. The laser irradiation is ceased as soon as micro-bubbles are detected. With this automatic approach it was possible to observe invisible lesions, an intact photoreceptor layer and a reconstruction of the RPE within one week.

  9. Pneumatic actuator with hydraulic control

    NASA Astrophysics Data System (ADS)

    Everett, Hobart R., Jr.

    1992-11-01

    The present invention provides a pneumatically powered actuator having hydraulic control for both locking and controlling the velocity of an output rod without any sponginess. The invention includes a double-acting pneumatic actuator having a bore, a piston slidably engaged within the bore, and a control rod connected to the piston. The double-acting pneumatic actuator is mounted to a frame. A first double-acting hydraulic actuator having a bore, a piston slidably engaged within the bore, and a follower rod mounted to the piston is mounted to the frame such that the follower rod is fixedly connected to the control rod. The maximum translation of the piston within the bore of the first double-acting hydraulic actuator provides a volumetric displacement V1. The present invention also includes a second double-acting hydraulic actuator having a bore, a piston slidably engaged within the bore, and an output rod mounted to the piston. The maximum translation of the piston within the bore of the second double-acting hydraulic actuator provides a volumetric displacement V2, where V2=V1. A pair of fluid ports in each of the first and second double-acting hydraulic cylinders are operably connected by fluid conduits, one of which includes a valve circuit which may be used to control the velocity of the output rod or to lock the output rod in a static position by regulating the flow of hydraulic fluid between the double-acting cylinders.

  10. Electric versus hydraulics versus pneumatics

    SciTech Connect

    Not Available

    1985-01-01

    This book presents a collection of papers from a conference which considered the advantages and disadvantages of electric, hydraulic and pneumatic drives and actuators. The volume follows on the success of the 1983 conference on electric and hydraulic drives. Topics considered include fork lift trucks - an ideal application for regenerative transmissions; a hybrid-electric power system with hydrostatic transmission; electrics and hydraulics on roadheader machinery; hydraulic, electrical, pneumatic control - which way to go. an electrically-powered servo to drive the two axes of a missile launching platform - pros and cons when compared with the traditional hydraulic solution; the encapsulation of a novel intrinsically safe displacement transducer; mobile cryogenic pumping systems; automation of a wood-turning machine, hydraulic or electric. The choice of a servo motor for a specific application; developments in the design and control of pneumatic linear actuators; compressed air purification for instrumentation in the high technology industries; trends in prime mover choice for powered hand tools; and choosing the drive system for the right application.

  11. Pneumatic well casing pressure regulating system

    SciTech Connect

    Flohr, M.C.

    1987-10-20

    A pneumatic well casing pressure regulating system is described comprising: a hydraulically actuated choke for relieving well casing pressure; a continually running source of pneumatic pressure pulses; first means for applying pulses of hydraulic fluid corresponding to the pneumatic pressure pulses to the choke for opening the choke one step for each pulse of hydraulic fluid when actual casing pressure is higher than a desired casing pressure; and second means for applying pulses of hydraulic fluid corresponding to the pneumatic pressure pulses to the choke for closing the choke one step for each pulse of hydraulic fluid when actual casing pressure is less than a desired casing pressure.

  12. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  13. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  14. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  15. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  16. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  17. Experimental Plan for EDF Energy Creep Rabbit Graphite Irradiations- Rev. 2 (replaces Rev. 0 ORNL/TM/2013/49).

    SciTech Connect

    Burchell, Timothy D

    2014-07-01

    The experimental results obtained here will assist in the development and validation of future models of irradiation induced creep of graphite by providing the following data: Inert creep stain data from low to lifetime AGR fluence Inert creep-property data (especially CTE) from low to lifetime AGR fluence Effect of oxidation on creep modulus (by indirect comparison with experiment 1 and direct comparison with experiment 3 NB. Experiment 1 and 3 are not covered here) Data to develop a mechanistic understanding, including oAppropriate creep modulus (including pinning and high dose effects on structure) oInvestigation of CTE-creep strain behavior under inert conditions oInformation on the effect of applied stress/creep strain on crystallite orientation (requires XRD) oEffect of creep strain on micro-porosity (requires tomography & microscopy) This document describes the experimental work planned to meet the requirements of project technical specification [1] and EDF Energy requests for additional Pre-IE work. The PIE work is described in detail in this revision (Section 8 and 9).

  18. RANGE INCREASER FOR PNEUMATIC GAUGES

    DOEpatents

    Fowler, A.H.; Seaborn, G.B. Jr.

    1960-09-27

    An improved pneumatic gage is offered in which the linear range has been increased without excessive air consumption. This has been accomplished by providing an expansible antechamber connected to the nozzle of the gage so that the position of the nozzle with respect to the workpiece is varied automatically by variation in pressure within the antechamber. This arrangement ensures that the nozzle-to-workpiece clearance is maintained within certain limits, thus obtaining a linear relation of air flow to nozzle-to-workpiece clearance over a wider range.

  19. Pneumatically tunable optofluidic dye laser

    NASA Astrophysics Data System (ADS)

    Song, Wuzhou; Psaltis, Demetri

    2010-02-01

    We presented a tunable optofluidic dye laser with integrated elastomeric air-gap etalon controlled by air pressure. The chip was fabricated with polydimethylsiloxane (PDMS) via replica molding. It comprises a liquid waveguide and microscale air-gap mirrors providing the feedback. The lasing wavelength is chosen by the interference between two parallel PDMS-air interfaces inside the internal tunable air-gap etalon, of which pneumatic tuning can be realized by inflating the air-gap etalon with compressed air. This dye laser exhibits a pumping threshold of 1.6 μJ/pulse, a lasing linewidth of 3 nm, and a tuning range of 14 nm.

  20. Pneumatic conveying of pulverized solvent refined coal

    DOEpatents

    Lennon, Dennis R.

    1984-11-06

    A method for pneumatically conveying solvent refined coal to a burner under conditions of dilute phase pneumatic flow so as to prevent saltation of the solvent refined coal in the transport line by maintaining the transport fluid velocity above approximately 95 ft/sec.

  1. Note: A fast pneumatic sample-shuttle with attenuated shocks

    SciTech Connect

    Biancalana, Valerio; Dancheva, Yordanka; Stiaccini, Leonardo

    2014-03-15

    We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

  2. Caudal Pneumaticity and Pneumatic Hiatuses in the Sauropod Dinosaurs Giraffatitan and Apatosaurus

    PubMed Central

    Wedel, Mathew J.; Taylor, Michael P.

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula—those that leave few or no skeletal traces—in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy. PMID:24205162

  3. Pneumatic transfer of solids into wells

    SciTech Connect

    Sweatman, R. E.; Freeman, E. R.; Gottschling, J.; Simon, J.

    1985-04-23

    A method for pneumatically transferring particulate solid materials into an earth formation penetrated by a well bore is shown. A gas is flowed into the well bore to establish the desired injection rate and pressure. A particulate solid material is then added to the established gas flow passing into the well bore by flowing a gas containing an entrained particulate solid material into the established gas flow to thereby transfer the solid particulate material pneumatically into the well bore.

  4. Pneumatic fracturing of low permeability media

    SciTech Connect

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  5. Promising pneumatic punchers for borehole drilling

    SciTech Connect

    A.A. Lipin

    2005-03-15

    The state of borehole drilling by downhole pneumatic punchers and their potential use in open and underground mining as well as in exploration for reliable sampling are analyzed. Performance specification is presented for the new-generation pneumatic punchers equipped with a pin tool, effectively operating at a compressed-air pressure of 0.5-0.7 MPa, and with an additional extended exhaust from the power stroke chamber during working cycle.

  6. Carbon Nanotube Amperometric Chips with Pneumatic Micropumps

    NASA Astrophysics Data System (ADS)

    Tsujita, Yuichi; Maehashi, Kenzo; Matsumoto, Kazuhiko; Chikae, Miyuki; Torai, Soichiro; Takamura, Yuzuru; Tamiya, Eiichi

    2008-04-01

    We fabricated carbon nanotube (CNT) amperometric chips with pneumatic micropumps by the combination of amperometric biosensors based on CNT-arrayed electrodes and microchannels with pneumatic micropumps made of poly(dimethylsiloxane). On the chip, phosphate buffer solution and potassium ferricyanide, K3[Fe(CN)6], were introduced into the CNT electrodes using each pneumatic micropump and electrochemically measured by differential pulse voltammetry. The results indicate that our chip can automatically exchange reagents on the CNT electrodes and clearly detect molecules. Moreover, by modifying the CNT electrodes with enzyme glucose oxidase, glucose molecules could be detected using our chips by cyclic voltammetry and chronoamperometry. We conclude that microfluidic chips with CNT-arrayed electrodes are a promising candidate for the development of hand-held electrochemical biosensors.

  7. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  8. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  9. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  10. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  11. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  12. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  13. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  14. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  15. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  16. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  17. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  18. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  19. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  20. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  1. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  2. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  3. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  4. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  5. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  6. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  7. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  8. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  9. Pneumatic boot for helicopter rotor deicing

    NASA Technical Reports Server (NTRS)

    Blaha, B. J.; Evanich, P. L.

    1981-01-01

    Pneumatic deicer boots for helicopter rotor blades were tested. The tests were conducted in the 6 by 9 ft icing research tunnel on a stationary section of a UH-IH helicopter main rotor blade. The boots were effective in removing ice and in reducing aerodynamic drag due to ice.

  10. Pneumatics. Student's Manual [and] Instructor's Guide.

    ERIC Educational Resources Information Center

    Notgrass, Troy

    The student's manual in this two-part instructional kit is designed to help the following types of students learn introductory technical material related to pneumatics: (1) groups of trade and industrial students with a variety of vocational objectives and (2) homogeneous groups in which the learning levels of individual students vary…

  11. Management of achalasia: surgery or pneumatic dilation.

    PubMed

    Richter, Joel E; Boeckxstaens, Guy E

    2011-06-01

    Achalasia is an esophageal motility disorder of unknown cause, characterised by aperistalsis of the esophageal body and impaired lower esophageal sphincter relaxation. Patients present at all ages, primarily with dysphagia for solids/liquids and bland regurgitation. The diagnosis is suggested by barium esophagram or endoscopy and confirmed by esophageal manometry. Achalasia cannot be cured. Instead, our goal is to relieve symptoms, improve esophageal emptying and prevent the development of megaesophagus. The most successful therapies are pneumatic dilation and surgical myotomy. The advantages of pneumatic dilation include an outpatient procedure, minimal pain, return to work the next day, mild if any GERD, and can be performed in any age group and even during pregnancy. Pneumatic dilation does not hinder future myotomy, and all cost analyses find it less expensive than Heller myotomy. Laparoscopic myotomy with a partial fundoplication has the advantage of being a single procedure, dysphagia relief is longer at the cost of more troubling heartburn, and a myotomy may be more effective treatment in adolescents and younger adults, especially men. Over a two year horizon, the clinical success of pneumatic dilation and laparoscopic myotomy are comparable in a recent large European randomised trial. The prognosis for achalasia patients to return to near-normal swallowing and good quality of life are excellent, but few are "cured" with a single treatment and intermittent "touch up" procedures may be required. PMID:21303915

  12. Analysis of fine coal pneumatic systems

    SciTech Connect

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying size consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.

  13. Field demonstration of two pneumatic backfilling technologies

    SciTech Connect

    Dyni, R.C.; Burnett, M.; Philbin, D.

    1995-12-31

    This US Bureau of Mines (USBM) report summarizes a field demonstration of pneumatic backfilling technologies conducted at the abandoned Hillside Coal and Iron Slope in Vandling, PA. Researchers demonstrated two pneumatic backfilling technologies recently developed under the USBM`s Abandoned Mine Reclamation Research Program, the Pneumatic Pipefeeder and the High-Efficiency Ejector. Both systems had previously been evaluated at the USBM`s subsidence abatement investigation laboratory near Fairchance, PA. The objective of the demonstration was to fill 100% of the abandoned tunnel with backfill stone to prevent further subsidence. The pneumatic Pipefeeder was used for 21 days, at a rate of 63 to 124 t/d (69 to 136 st/d), to fill 88% of the tunnel. The High-Efficiency Ejector was used for 2 days, at a rate of 125 to 132 T/d (138 to 146 st/d) to fill the remaining 12% of the tunnel. The backfill placed by both systems was tightly compacted. The major problem encountered was wear on the polyethylene pipeline from the abrasion of the high-velocity backfill. The use of heavier steel pipe minimized the problem. A cost analysis for the entire project is given.

  14. PNEUMATIC FRACTIONATOR FOR CLEANING GINNED LINT

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. Spawned from discussions at a Cotton Incorporated Lint Cleaning Summit and building on 1970s research at the Southwestern Cotton Ginning Research Laboratory, an e...

  15. Evaluating a device for pneumatic lint cleaning

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Research exploring innovative techniques to clean ginned lint while reducing short fiber and neps has led to evaluations of a pneumatic fractionator. This device is typically used to determine foreign matter content of seed cotton at the USDA cotton ginning research laboratories. No modifications we...

  16. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    PubMed

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L; Benson, Roger B J; Choiniere, Jonah; Davidson, Amy; Norell, Mark A

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  17. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  18. Pneumatic hammer in aerostatic thrust bearings with single orifice compensation

    NASA Astrophysics Data System (ADS)

    Kong, Zhongke; Tao, Jizhong

    2013-01-01

    In dealing with the phenomenon of the pneumatic hammer in aerostatic thrust bearings, the vibrant model of the one-single freedom system has been established to study the pneumatic hammer from the point of sympathetic vibration. It is found that the bearings show a tendency to result in the pneumatic hammer with the increase of air supply pressure, and the occurrence probability of the pneumatic hammer will be reduced when the gas film thickness is maintained within a certain range. Meanwhile, the existence of the pneumatic hammer, which is caused by sympathetic vibration, is experimentally verified, and it is found that gas bearings undergo certain disturbance, which causes the system to produce micro breadth vibration. Accordingly, the micro breadth vibration causes the gas film and thrust face to form flow/structure coupled to excite the pneumatic hammer. Therefore, it provides another path to study the pneumatic hammer and is of academic value.

  19. Morphologic findings in the rabbit retina following irradiation with the free-running neodymium-YAG laser. Disruption of Bruch's membrane and its effect on the scarring process in the retina and choroid

    SciTech Connect

    van der Zypen, E.; Fankhauser, F.; Raess, K.; England, C.

    1986-07-01

    The scarring process induced within the retina and choroid of pigmented rabbits' eyes following irradiation with the neodymium-YAG laser (working in the free-running mode) was examined at the ultrastructural level. Scarring of the sensory retina proceeded rapidly and was well advanced two weeks after irradiation, whereas in the choroid, signs of repair were apparent only after six weeks. This difference in the rate of repair between the two tissues has a bearing on the scarring pattern in the retinochoroid as a whole. The severity of damage to the elastic component of Bruch's membrane also has important consequences in relation to the repair processes in the retina and choroid. Microfractures within this layer, while enabling migrating cells of various kinds to penetrate into the inner collagenous zone, did not prevent complete regeneration of the retinal pigment epithelium (RPE). In instances of greater rupture, however, RPE regeneration was found to stop at the border of the break, and the discontinuity produced within Bruch's membrane and the RPE allowed the glial scar to expand into the choroid. In this region, new formation of vessels was not found.

  20. Milestone M3FT-15OR0203112. Build redesigned HFIR rabbit capsules and make ready for insertion for irradiation in HFIR

    SciTech Connect

    Howard, Richard H; McDuffee, Joel Lee; Okuniewski, Maria A.

    2015-09-01

    This report details the fabrication and delivery of two Fuel Cycle Research and Development irradiation capsules (FCRP20 and FCRP03), with associated quality assurance documentation, to the High Flux Isotope Reactor. The capsules and documentation were delivered by September 30, 2015, thus meeting the deadline for milestone M3FT-15OR0203112. These irradiation experiments irradiate metal parallelepiped specimens that may consist of various compositions including uranium metal, steel, etc. This document contains a copy of the completed capsule fabrication request sheets, which detail all constituent components, pertinent drawings, etc., along with a detailed summary of the capsule assembly process performed by the Thermal Hydraulics and Irradiation Engineering Group (THIEG) in the Reactor and Nuclear Systems Division. A complete fabrication package record is maintained by THIEG and is available upon request.

  1. Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Feldman, Jason; Svehla, Danielle

    2003-01-01

    Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric

  2. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  3. Viral infections of rabbits.

    PubMed

    Kerr, Peter J; Donnelly, Thomas M

    2013-05-01

    Viral diseases of rabbits have been used historically to study oncogenesis (e.g. rabbit fibroma virus, cottontail rabbit papillomavirus) and biologically to control feral rabbit populations (e.g. myxoma virus). However, clinicians seeing pet rabbits in North America infrequently encounter viral diseases although myxomatosis may be seen occasionally. The situation is different in Europe and Australia, where myxomatosis and rabbit hemorrhagic disease are endemic. Advances in epidemiology and virology have led to detection of other lapine viruses that are now recognized as agents of emerging infectious diseases. Rabbit caliciviruses, related to rabbit hemorrhagic disease, are generally avirulent, but lethal variants are being identified in Europe and North America. Enteric viruses including lapine rotavirus, rabbit enteric coronavirus and rabbit astrovirus are being acknowledged as contributors to the multifactorial enteritis complex of juvenile rabbits. Three avirulent leporid herpesviruses are found in domestic rabbits. A fourth highly pathogenic virus designated leporid herpesvirus 4 has been described in Canada and Alaska. This review considers viruses affecting rabbits by their clinical significance. Viruses of major and minor clinical significance are described, and viruses of laboratory significance are mentioned. PMID:23642871

  4. MANUAL DEGATING OPERATIONS PERFORMED BY SLEDGEHAMMERS AND PNEUMATIC WEDGE SEPARATORS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MANUAL DEGATING OPERATIONS PERFORMED BY SLEDGE-HAMMERS AND PNEUMATIC WEDGE SEPARATORS. - Southern Ductile Casting Company, Shaking, Degating & Sand Systems, 2217 Carolina Avenue, Bessemer, Jefferson County, AL

  5. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug was administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls, All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p less than 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p less than 0.05) and pericardial effusion (p less than 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p less than 0.05) or IB (p less than 0.01) and in the untreated, unirradiated rabbits (p less than 0.01). Early administration of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusion, and improved survival in this experimental model of radiation-induced heart disease.

  6. Pneumatic transport of coal by steam

    SciTech Connect

    Ekmann, J.M.; Wildman, D.J.; Mathur, M.P.; Klinzing, G.E.

    1985-01-01

    Steam has been suggested as the transport gas in power plant facilities where the availability high pressure steam already exists. The transport of coal pneumatically by the use of steam to a loading ratio of 10 has been studied experimentally in a 0.0107 meter diameter pipe. Analysis of the energy losses in transport of the steam-coal mixture has been carried out using a model based on thermodynamic and fluid mechanics principles. Good agreement between the data and model has been obtained.

  7. Pneumatic transport of coal by steam

    SciTech Connect

    Wildman, D.J.; Mathur, M.P.; Ekmann, J.M.; Klinzing, G.E.

    1984-01-01

    Steam has been suggested as the transport gas in power plant facilities where the availability of high pressure steam already exists. The transport of coal pneumatically by the use of steam to a loading ratio of 10 has been studied experimentally in a 3/8'' pipe. Analysis of the energy losses in transport of the steam-coal mixture has been carried out using a model based on thermodynamic and fluid mechanics principles. Good agreement between the data and model has been obtained. 4 references, 2 figures.

  8. Pneumatic Artificial Muscle Actuation and Modeling

    NASA Astrophysics Data System (ADS)

    Leephakpreeda, Thananchai; Wickramatunge, Kanchana C.

    2009-10-01

    A Pneumatic Artificial Muscle (PAM) yields a natural muscle-like actuator with a high force to weight ratio, a soft and flexible structure, and adaptable compliance for a humanoid robot, rehabilitation and prosthetic appliances to the disabled, etc. To obtain optimum design and usage, the mechanical behavior of the PAM need to be understood. In this study, observations of experimental results reveal an empirical model for relations of physical variables, contraction and air pressure within the PAM, as compared to mechanical characteristics, such as stiffness or/and pulling forces of the PAM available now in market.

  9. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  10. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  11. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  12. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  13. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  14. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  15. Evaluating a pneumatic fractionator for cleaning ginned lint

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. An experiment was conducted to evaluate the pneumatic fractionator as a lint cleaning device. No modifications were made to the standard device, except that air p...

  16. Anatomical Factors Influencing Pneumatization of the Petrous Apex

    PubMed Central

    Kim, Min-Ju; Lee, Seunghun; Choi, Hana

    2015-01-01

    Objectives Aim of the present study was to define the relationship between petrous apex pneumatization and the nearby major anatomical landmarks using temporal bone computed tomography (CT) images. Methods This retrospective, Institutional Review Board-approved study analyzed CT images of 84 patients that showed normal findings bilaterally. Pneumatization of the petrous apex was classified using two methods. Eight parameters were as follows: angle between the posterior cranial fossa and internal auditory canal, Morimitsu classification of anterior epitympanic space, distance between the carotid canal and jugular bulb, distance between the cochlear modiolus and carotid canal, distance between the tympanic segment and jugular bulb, high jugular bulb, distance between the vertical segment and jugular bulb, and distance between the lateral semicircular canals and middle cranial fossa. Results There was a significant difference in Morimitsu classification of the anterior epitympanic space between the two classification methods. Poorly pneumatic upper petrous apices were distributed uniformly in three types of Morimitsu classification, but more pneumatic upper petrous apices were found more often in anterior type. Lower petrous apex was well pneumatized regardless of the types of anterior epitympanic space, but the largest amount of pneumatization was found more frequently in the anterior type of anterior epitympanic space. Conclusion This study showed that there was no reliable anatomic marker to estimate petrous apex pneumatization and suggests that the pneumatization of the petrous apex may be an independent process from other part of the temporal bone, and may not be influenced by the nearby major anatomical structures in the temporal bone. In this study, the anterior type of anterior epitympanic space was found to be closely related to more well-pneumatized petrous apices, which implies that the anterior saccule of the saccus medius may be the main factor

  17. Scaling of pneumatic digital logic circuits.

    PubMed

    Duncan, Philip N; Ahrar, Siavash; Hui, Elliot E

    2015-03-01

    The scaling of integrated circuits to smaller dimensions is critical for achieving increased system complexity and speed. Digital logic circuits composed of pneumatic microfluidic components have to this point been limited to a circuit density of 2-4 gates cm(-2), constraining the complexity of the digital systems that can be achieved. We explored the use of precision machining techniques to reduce the size of pneumatic valves and resistors, and to achieve more accurate and efficient placement of ports and vias. In this way, we attained an order of magnitude increase in circuit density, reaching as high as 36 gates cm(-2). A 12-bit binary counter circuit composed of 96 gates was realized in an area of 360 mm(2). The reduction in size also brought an order of magnitude increase in speed. The frequency of a 13-stage ring oscillator increased from 2.6 Hz to 22.1 Hz, and the maximum clock frequency of a binary counter increased from 1/3 Hz to 6 Hz. PMID:25591784

  18. Transforming insect electromyograms into pneumatic muscle control

    NASA Astrophysics Data System (ADS)

    Rutter, Brandon; Mu, Laiyong; Ritzmann, Roy; Quinn, Roger

    2006-05-01

    Robots can serve as hardware models for testing biological hypotheses. Both for this reason and to improve the state of the art of robotics, we strive to incorporate biological principles of insect locomotion into robotic designs. Previous research has resulted in a line of robots with leg designs based on walking and climbing movements of the cockroach Blaberus discoidalis. The current version, Robot V, uses muscle-like Braided Pneumatic Actuators (BPAs). In this paper, we use recorded electromyograms (EMGs) to drive robot joint motion. A muscle activation model was developed that transforms EMGs recorded from behaving cockroaches into appropriate commands for the robot. The transform is implemented by multiplying the EMG by an input gain thus generating an input pressure signal, which is used to drive a one-way closed loop pressure controller. The actuator then can be modeled as a capacitance with input rectification. The actuator exhaust valve is given a leak rate, making the transform a leaky integrator for air pressure, which drives the output force of the actuator. We find parameters of this transform by minimizing the difference between the robot motion produced and that observed in the cockroach. Although we have not reproduced full-amplitude cockroach motion using this robot, results from evaluation on reduced-amplitude cockroach angle data strongly suggest that braided pneumatic actuators can be used as part of a physical model of a biological system.

  19. Continued Development and Improvement of Pneumatic Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in the first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel

  20. Cysticercosis in laboratory rabbits.

    PubMed

    Owiny, J R

    2001-03-01

    There are no data on the current incidence of Taenia pisiformis in laboratory rabbits. Two cases of cysticercosis most likely due to T. pisiformis in laboratory rabbits (intermediate host) are presented. Both rabbits had no contact with dogs (final host); their caretakers did not work with dogs, and these caretakers changed into facility scrubs and wore gloves when working with the rabbits. Rabbit 1 may have been infected after being fed hay at our facility. In light of the life cycle of the parasite and the history of rabbit 2, it potentially could have been infected prior to arrival at our facility. There have been only three cases of tapeworm cysts in rabbits in our facility (average daily census, 250) during the last 10 years (incidence, < 1%). This report indicates that although cysticercosis is rare in laboratory rabbits, one should always be aware of such incidental findings. Although it may not produce overt illness in the rabbit, hepatic migration could adversely affect the outcome of some experimental procedures PMID:11300689

  1. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  2. Pneumatic grading applied to sugarcane products

    SciTech Connect

    Roka A., G.A.; Boisan C., M.A.; Frolov, V.F.

    1988-09-10

    There are secondary products from processing sugar cane, consisting of light particles having irregular elongated forms and falling into various size fractions: bagasso up to 5 mm, bagassilo 5-0.3 mm, and meole < 0.3 mm. These contain water, since they are obtained in the early stages of making cane sugar. Much of the bagasso and bagassilo is burned in situ in steam boilers at the sugar plants. Also, the various fractions are used in making paper, wood-straw board, and as ingredients for fodder and fertilizers, in addition to raw material in furfural production. These uses require grading and drying. In pneumatic grading, one uses the outgoing combustion products from the steam boilers at the plants and at the same time provides drying. Experiments were conducted in order to perform design calculations on grading these products.

  3. Asymmetric pneumatization of the petrous apex.

    PubMed

    Roland, P S; Meyerhoff, W L; Judge, L O; Mickey, B E

    1990-07-01

    Three patients with high-intensity MR signals from one petrous apex, but nonpathologic fine-cut computed tomography are reported. In two of the three patients, normal bone marrow within the petrous apex on one side is believed to have generated the high-intensity signal. In one of the three patients, the etiology of the MR image remains obscure, but may represent the earliest stages of petrous cholesterol granuloma or mucocele. We have reviewed 500 head CT scans performed for non-otologic reasons, in an attempt to establish the frequency of this finding. The literature on MR and CT imaging of the petrous apex and asymmetric pneumatization of the petrous apex is reviewed. PMID:2117735

  4. Optimizing pneumatic conveying of biomass materials

    NASA Astrophysics Data System (ADS)

    DiCianni, Matthew Edward Michael

    2011-12-01

    Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.

  5. Astroviruses in Rabbits

    PubMed Central

    Moschidou, Paschalina; Pinto, Pierfrancesco; Catella, Cristiana; Desario, Constantina; Larocca, Vittorio; Circella, Elena; Bànyai, Krisztian; Lavazza, Antonio; Magistrali, Chiara; Decaro, Nicola; Buonavoglia, Canio

    2011-01-01

    By screening rabbits with enterocolitis or enteritis complex and asymptomatic rabbits, we identified a novel astrovirus. The virus was distantly related (19.3%–23.7% aa identity) in the capsid precursor to other mammalian astroviruses within the Mamastrovirus genus. By using real-time reverse transcription PCR, with specific primers and probes and targeting a conserved stretch in open reading frame 1b, we found rabbit astrovirus in 10 (43%) of 23 samples from animals with enteric disease and in 25 (18%) of 139 samples from asymptomatic animals in Italy during 2005–2008. The mean and median titers in the positive animals were 102× and 103× greater, respectively, in the symptomatic animals than in the asymptomatic animals. These findings support the idea that rabbit astroviruses should be included in the diagnostic algorithm of rabbit enteric disease and animal experiments to increase information obtained about their epidemiology and potential pathogenic role. PMID:22172457

  6. A PNEUMATIC CONVEYING TEST RIG FOR MUNICIPAL SOLID WASTE FRACTIONS

    EPA Science Inventory

    This report analyzes the material properties and system parameters relevant to the pneumatic conveying of municipal solid waste and its processed fractions. Comparisons are made with the conveying of conventional industrial feedstocks, and a rationale for sizing and specification...

  7. Detail, north end of console and pneumatic tube message port, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, north end of console and pneumatic tube message port, also showing mirror to reflect view of communications switchboard - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  8. 14 CFR 25.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the maximum normal operating pressure. (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and proof pressure...

  9. Inline evenflow material distributor for pneumatic material feed systems

    DOEpatents

    Thiry, Michael J.

    2007-02-20

    An apparatus for reducing clogs in a pneumatic material feed line, such as employed in abrasive waterjet machining systems, by providing an evenflow feed of material therethrough. The apparatus preferably includes a hollow housing defining a housing volume and having an inlet capable of connecting to an upstream portion of the pneumatic material feed line, an outlet capable of connecting to a downstream portion of the pneumatic material feed line, and an air vent located between the inlet and outlet for venting excess air pressure out from the housing volume. A diverter, i.e. an impingement object, is located at the inlet and in a path of incoming material from the upstream portion of the pneumatic material feed line, to break up clumps of ambient moisture-ridden material impinging on the diverter. And one or more filter screens is also preferably located in the housing volume to further break up clumps and provide filtering.

  10. 23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  11. PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR AREA TO REMOVE ANY EXCESS OR LOOSE SAND. - Stockham Pipe & Fittings Company, Ductile Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  12. Dynamic behavior of valves with pneumatic chamber for reciprocating compressors

    NASA Astrophysics Data System (ADS)

    Kato, M.; Kurohashi, M.; Aoshima, M.

    1993-10-01

    This paper describes the dynamic behavior of valves with pneumatic chambers for reciprocating compressors. These are known as 'damped valves' and are capable of reducing the impact on the valve seat and valve stopper. The characteristics of the dynamic behavior of the damped valves were clarified by calculating newly derived governing equations of valve dynamics. From the calculated results, it becomes apparent that the volume of the pneumatic chambers and the clearance between the pneumatic chamber and the valve have a large influence on the impact speed of the valves. Furthermore, the valves tend to close later for a higher compressor speed to oscillate at a larger amplitude for a lower density of gas such as hydrogen. These tendencies show that the selection of the specification of damped valves is very important. The stiffness of the valve spring and the lift of the valve also affect valve behavior as with valves without pneumatic chambers.

  13. 118. TUBING AT BACK SIDE OF PNEUMATIC SUPPLY PANEL IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    118. TUBING AT BACK SIDE OF PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  15. Dry ice plug for hydraulic and pneumatic pipe flushing

    NASA Technical Reports Server (NTRS)

    Francino, L.; Rauch, S.

    1972-01-01

    Development of technique to clear blockages in hydraulic and pneumatic pipes is discussed. Technique consists of using dry ice plug to separate sensitive components from flushing fluid. Diagram of equipment and principles of operation are presented.

  16. Evaluation of neutron flux parameters in irradiation sites of research reactor using the Westcott-formalism for the k0 neutron activation analysis method

    NASA Astrophysics Data System (ADS)

    Kasban, H.; Hamid, Ashraf

    2015-12-01

    Instrumental Neutron Activation Analysis using k0 (k0-INAA) method has been used to determine a number of elements in sediment samples collected from El-Manzala Lake in Egypt. k0-INAA according to Westcott's formalism has been implemented using the complete irradiation kit of the fast pneumatic rabbit and some selected manually loaded irradiation sites for short and long irradiation at Egypt Second Research Reactor (ETRR-2). Zr-Au and Co sets as neutron flux monitors are used to determine the neutron flux parameters (f and α) in each irradiation sites. Two reference materials IAEA Soil-7 samples have been inserted and implemented for data validation and an internal monostandard multi monitor used (k0 based IM-NAA). It was given a good agreement between the experimental analyzed values and that obtained of the certified values. The major and trace elements in the sediment samples have been evaluated with the use of Co as an internal and Au as an external monostandard comparators. The concentrations of the elements (Cr, Mn and Zn) in the sediment samples of the present work are discussed regarding to those obtained from other sites.

  17. Safety aspects of pneumatic transport. Information Circular/1985

    SciTech Connect

    Bowers, E.T.

    1985-01-01

    The work reported here deals with the safety aspects of pneumatic transport of underground coal, as well as the hazards inherent in more conventional haulage systems. Included are three designs for different applications of pneumatic haulage: off-loading a continuous-mining machine on a room-and-pillar section, vertical hoisting through a 1,200-ft shaft, and off-loading a tunnel-boring machine driving a 2,000-ft tunnel.

  18. High-Torque, Lightweight, Pneumatically Driven Wrench For Small Spaces

    NASA Technical Reports Server (NTRS)

    Miller, Thomas W.

    1995-01-01

    Pneumatically driven wrench provides torque up to 3,000 lb. per ft. in small space. Designed to reach into 2.6 x 2.75 x 6 in. pocket. Weighs approximately 25 lbs. Includes reversible pneumatic motor (electric motor could be used instead) and slip clutch. Also includes device indicating total angle through which wrench turned bolt or nut. This feature used for turn-of-the-nut tightening method.

  19. Development of pneumatic actuator with low-wave reflection characteristics

    NASA Astrophysics Data System (ADS)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  20. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  1. A New Type of Motor: Pneumatic Step Motor.

    PubMed

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2007-02-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  2. Hepatitis E Virus in Farmed Rabbits, Wild Rabbits and Petting Farm Rabbits in the Netherlands.

    PubMed

    Burt, Sara A; Veltman, Jorg; Hakze-van der Honing, Renate; Schmitt, Heike; van der Poel, Wim H M

    2016-09-01

    Rabbits have been suggested as a zoonotic source of Hepatitis E virus. Phylogenetic analysis of HEV isolates from farmed, wild and pet rabbits in the Netherlands (23, 0, and 60 % respectively) showed them to be grouped amongst published rabbit HEV sequences and distinct from most human isolates. Dutch rabbits are unlikely to be a zoonotic source. PMID:27147250

  3. Oil well rabbit

    SciTech Connect

    Yerian, H.W.

    1983-10-18

    A well rabbit is described which has a high gas seal capacity as well as resistance to wear and structural failure. The rabbit comprises a one-piece elongated generally cylindrical body having external circumferential gas-sealing grooves spaced along its length and a set of helically oriented slots at its lower end. The circumferential grooves, which work collectively in the manner of a labyrinth seal, are undercut in a way to deflect escaping gas streams and promote turbulence to enhance their gas-sealing capability. The undercut profile and relative spacing of the grooves leaves a large surface area between the grooves for distributing radial forces and thereby decreasing the wear rate of the rabbit. The helically oriented slots convert energy of upward escaping gas into rotational energy in the rabbit. (3 claims.

  4. Novel bocaparvoviruses in rabbits.

    PubMed

    Lanave, G; Martella, V; Farkas, S L; Marton, S; Fehér, E; Bodnar, L; Lavazza, A; Decaro, N; Buonavoglia, C; Bányai, K

    2015-11-01

    Bocaparvovirus is a newly established genus within the family Parvoviridae and has been identified as a possible cause of enteric, respiratory, reproductive/neonatal and neurological disease in humans and several animal species. In this study, metagenomic analysis was used to identify and characterise a novel bocaparvovirus in the faeces of rabbits with enteric disease. To assess the prevalence of the novel virus, rectal swabs and faecal samples obtained from rabbits with and without diarrhoea were screened with a specific PCR assay. The complete genome sequence of the novel parvovirus was reconstructed. The virus was distantly related to other bocaparvoviruses; the three ORFs shared 53%, 53% and 50% nucleotide identity, respectively, to homologous genes of porcine bocaparvoviruses. The virus was detected in 8/29 (28%) and 16/95 (17%) samples of rabbits with and without diarrhoea, respectively. Sequencing of the capsid protein fragment targeted by the diagnostic PCR identified two distinct bocaparvovirus populations/sub-types, with 91.7-94.5% nucleotide identity to each other. Including these novel parvoviruses in diagnostic algorithms of rabbit diseases might help inform their potential pathogenic role and impact on rabbit production and the virological profiles of laboratory rabbits. PMID:26383859

  5. Viral diseases of the rabbit.

    PubMed

    Krogstad, Aric P; Simpson, Janet E; Korte, Scott W

    2005-01-01

    Viral disease in the rabbit is encountered infrequently by the clinical practitioner; however, several viral diseases were reported to occur in this species. Viral diseases that are described in the rabbit primarily may affect the integument, gastrointestinal tract or, central nervous system or maybe multi-systemic in nature. Rabbit viral diseases range from oral papillomatosis, with benign clinical signs, to rabbit hemorrhagic disease and myxomatosis, which may result in significant clinical disease and mortality. The wild rabbit may serve as a reservoir for disease transmission for many of these viral agents. In general, treatment of viral disease in the rabbit is supportive in nature. PMID:15585192

  6. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    SciTech Connect

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  7. Salivary Stone Pneumatic Lithotripsy in a Live Porcine Model.

    PubMed

    Walvekar, Rohan R; Hoffman, Henry T; Kolenda, Jack; Hernandez, Stephen

    2016-06-01

    The purpose of this study is to evaluate the efficacy of endoscopic fragmentation and removal of artificial calculi in a live porcine model employing intracorporeal pneumatic lithotripsy. In this experimental study, 7 submandibular ducts were accessed and artificial calculi placed. A salivary pneumatic lithotripter probe was inserted through an interventional sialendoscope to fragment the calculi. A salivary duct catheter was then used to flush stone fragments, followed by endoscopy to assess complete fragmentation and ductal trauma. Ultimately, 7 artificial stones (3-10 mm, 4F/5F) were successfully fragmented without causing significant endoluminal trauma. Number of pulses for adequate stone fragmentation averaged 20 (range, 5-31). In all cases, stone fragments were successfully flushed out with the salivary duct catheter. Postprocedure endoscopy confirmed ductal integrity in all 7 ducts. While more studies are needed, this preliminary animal model demonstrates efficacy of endoscopic pneumatic lithotripsy for the management of sialolithiasis. PMID:27048662

  8. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  9. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  10. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  11. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  12. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  13. Evaluation of a pneumatic Martian soil sampler concept

    NASA Technical Reports Server (NTRS)

    Schaefer, John L.; Neathery, James K.; Stencel, John M.

    1994-01-01

    The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

  14. Photodynamic therapy on normal rabbit mandible

    NASA Astrophysics Data System (ADS)

    Fan, Kathleen F.; Hopper, Colin; Speight, Paul M.; Davies, Claire; Bown, Stephen G.

    1995-03-01

    Photodynamic therapy has been proposed as an intra-operative adjunct to surgical resection of tumors invading bone. To assess this, we studied the effects of PDT in normal bone. Forty- four rabbits were sensitized with Photofrin 3 mg/kg, 5-aminolaevulinic acid (ALA) 400 mg/kg, or meso-tetrahydroxyphenylchlorin (mTHPC) 0.3 mg/kg. A mandibular incisor was removed and the socket irradiated with a cylindrical diffusion fiber (630 nm Photofrin and ALA, 650 nm mTHPC, 100 J per treatment). Irradiation was given 1 or 48 hours after Photofrin, 72 hours after mTHPC, whilst 2 doses were given 2.5 and 4 hours after the first fractionated dose of ALA. The socket of the ipsilateral maxillary incisor was used as a nonirradiated control to assess healing without PDT. Other controls assessed healing after irradiation of unsensitized animals. Rabbits were killed 3, 10, and 21 days after treatment. Tooth socket healing appeared to be the same in all groups of animals with evidence of woven bone formation by 10 days. We conclude that PDT is unlikely to have any effect on healing in normal bone, which makes it suitable for treating tumors invading bone.

  15. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  17. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... paraplegics walk. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the Food... distribution before May 28, 1976. Any other rigid pneumatic structure orthosis shall have an approved PMA or...

  18. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... paraplegics walk. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the Food... distribution before May 28, 1976. Any other rigid pneumatic structure orthosis shall have an approved PMA or...

  19. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  20. 7 CFR 3201.86 - Pneumatic equipment lubricants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Pneumatic equipment lubricants. 3201.86 Section 3201.86 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF PROCUREMENT AND PROPERTY MANAGEMENT, DEPARTMENT OF AGRICULTURE GUIDELINES FOR DESIGNATING BIOBASED PRODUCTS FOR FEDERAL PROCUREMENT Designated Items § 3201.86...

  1. 14 CFR 23.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... elements must be burst pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the maximum normal operating pressure. (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and proof pressure tested to 1.5 times, the maximum normal operating pressure. (c) An analysis, or...

  2. Assessing a pneumatic fractionator as a lint cleaning device

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A study assessed a pneumatic fractionator as a lint cleaning device for ginned lint. Results from a test that used two line pressures and three fractionation times showed that higher line pressure and longer fractionation time produced fiber that was shorter in staple length, contained more neps, a...

  3. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  4. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  5. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  6. The Pneumatic Common: Learning in, with and from the Air

    ERIC Educational Resources Information Center

    Ford, Derek R.

    2015-01-01

    Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…

  7. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  8. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  9. Note: Pneumatically modulated liquid delivery with feedback control

    NASA Astrophysics Data System (ADS)

    Field, C. R.; Terray, A. V.; Lubrano, A. L.; Rogers, D. A.; Hart, S. J.; Rose-Pehrsson, S. L.

    2012-07-01

    We present the design and characterization of a pneumatically driven liquid delivery system using an embedded microcontroller with feedback control capable of maintaining a stable, constant flow rate over several hours of operation. Flow rates with relative standard deviations less than 1% were achieved and compared to a typical laboratory syringe pump.

  10. Pneumatic vacuum tube message center, basement room 23, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  11. Pneumatic Power Drive Wheel and related assembly for Turntable, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic Power Drive Wheel and related assembly for Turntable, with scale. Not in use August 1994. Turntable rotated with engine and tender on balance by two persons, one on either side at ground level - East Broad Top Railroad & Coal Company, Roundhouse, State Route 994, West of U.S. Route 522, Rockhill Furnace, Huntingdon County, PA

  12. Adaptive backstepping slide mode control of pneumatic position servo system

    NASA Astrophysics Data System (ADS)

    Ren, Haipeng; Fan, Juntao

    2016-06-01

    With the price decreasing of the pneumatic proportional valve and the high performance micro controller, the simple structure and high tracking performance pneumatic servo system demonstrates more application potential in many fields. However, most existing control methods with high tracking performance need to know the model information and to use pressure sensor. This limits the application of the pneumatic servo system. An adaptive backstepping slide mode control method is proposed for pneumatic position servo system. The proposed method designs adaptive slide mode controller using backstepping design technique. The controller parameter adaptive law is derived from Lyapunov analysis to guarantee the stability of the system. A theorem is testified to show that the state of closed-loop system is uniformly bounded, and the closed-loop system is stable. The advantages of the proposed method include that system dynamic model parameters are not required for the controller design, uncertain parameters bounds are not need, and the bulk and expensive pressure sensor is not needed as well. Experimental results show that the designed controller can achieve better tracking performance, as compared with some existing methods.

  13. The Cutaneous Rabbit Revisited

    ERIC Educational Resources Information Center

    Flach, Rudiger; Haggard, Patrick

    2006-01-01

    In the cutaneous rabbit effect (CRE), a tactile event (so-called attractee tap) is mislocalized toward an adjacent attractor tap. The effect depends on the time interval between the taps. The authors delivered sequences of taps to the forearm and asked participants to report the location of one of the taps. The authors replicated the original CRE…

  14. Pneumatic fractures in Confined Granular Media

    NASA Astrophysics Data System (ADS)

    Eriksen, Fredrik K.; Toussaint, Renaud; Jørgen Måløy, Knut; Grude Flekkøy, Eirik; Turkaya, Semih

    2016-04-01

    We will present our ongoing study of the patterns formed when air flows into a dry, non-cohesive porous medium confined in a horizontal Hele-Shaw cell. This is an optically transparent system consisting of two glass plates separated by 0.5 to 1 mm, containing a packing of dry 80 micron beads in between. The cell is rectangular and has an air-permeable boundary (blocking beads) at one short edge, while the other three edges are completely sealed. The granular medium is loosely packed against the semi-permeable boundary and fills about 80 % of the cell volume. This leaves an empty region at the sealed side, where an inlet allows us to set and maintain the air at a constant overpressure (0.1 - 2 bar). For the air trapped inside the cell to relax its overpressure it has to move through the deformable granular medium. Depending on the applied overpressure and initial density of the medium, we observe a range of different behaviors such as seepage through the pore-network with or without an initial compaction of the solid, formation of low density bubbles with rearrangement of particles, granular fingering/fracturing, and erosion inside formed channels/fractures. The experiments are recorded with a high-speed camera at a framerate of 1000 images/s and a resolution of 1024x1024 pixels. We use various image processing techniques to characterize the evolution of the air invasion patterns and the deformations in the surrounding material. The experiments are similar to deformation processes in porous media which are driven by pore fluid overpressure, such as mud volcanoes and hydraulic or pneumatic (gas-induced) fracturing, and the motivation is to increase the understanding of such processes by optical observations. In addition, this setup is an experimental version of the numerical models analyzed by Niebling et al. [1,2], and is useful for comparison with their results. In a directly related project [3], acoustic emissions from the cell plate are recorded during

  15. a Study of the Systematics of Low-Lying Levels in Nuclei in the Mass Region A=80 with a NIM Controlled Rabbit System.

    NASA Astrophysics Data System (ADS)

    Fry, Leolan Harold, Jr.

    Heavy ion reactions were used to produce nuclei away from beta stability in the mass region A(TURNEQ)80. The irradiated targets were transported to an isolated detector site using a rapid target transfer (Rabbit) system to aid in the study of weak products produced in these reactions and to protect the Ge(Li) detectors used in the experiments. The "Rabbit" system constructed for this purpose was a pneumatic type and was controlled by a NIM controller. The NIM controller, a unique feature of this system, was constructed with TTL and CMOS circuits and works in conjunction with a leaky integrator and a UNIVAC 6130 computer. The "Rabbit" system was used in lifetime, gamma-gamma coincidence measurements and beta-gamma coincidence measurements. Lifetime measurements were used to study the decay of ('79)Sr produced in the reaction ('54)Fe + ('28)Si at 90 MeV (lab). The lifetime of the ground state of ('79)Sr was measured and a positron feeding to the 39.3-keV level in ('79)Rb was established. Lifetime measurements were also used to study the decay of ('81m)Rb, which is produced in the reaction ('68)Zn + ('16)O at 56 MeV (lab). A positron feeding from the isomeric level in ('81)Rb to the 49.6 -keV level in ('81)Kr was established. In addition, lifetime measurements were used to help identify gamma rays produced in the reactions ('68)Zn + ('16)O and ('70)Ge + ('16)O at 56 MeV (lab). The reaction ('68)Zn + ('16)O was also studied with the gamma-gamma coincidence technique. Extensive level schemes were constructed and new levels were established for the decays of ('81)Rb and ('81)Sr. The beta-gamma coincidence technique was used in the study of the reaction ('70)Ge + ('16)O to investigate the ground state and isomeric levels of ('83)Y and ('84)Y. The order and relative separation of these levels were tentatively established for ('83)Y. The Q-value and J('(pi)) of the ground state were established and tentative J('(pi)) assignments were made for the isomeric levels in ('84)Y

  16. Rabbits killing birds revisited.

    PubMed

    Zhang, Jimin; Fan, Meng; Kuang, Yang

    2006-09-01

    We formulate and study a three-species population model consisting of an endemic prey (bird), an alien prey (rabbit) and an alien predator (cat). Our model overcomes several model construction problems in existing models. Moreover, our model generates richer, more reasonable and realistic dynamics. We explore the possible control strategies to save or restore the bird by controlling or eliminating the rabbit or the cat when the bird is endangered. We confirm the existence of the hyperpredation phenomenon, which is a big potential threat to most endemic prey. Specifically, we show that, in an endemic prey-alien prey-alien predator system, eradication of introduced predators such as the cat alone is not always the best solution to protect endemic insular prey since predator control may fail to protect the indigenous prey when the control of the introduced prey is not carried out simultaneously. PMID:16529776

  17. Rabbit care and husbandry.

    PubMed

    Bradley, Teresa

    2004-05-01

    This article provides information for the veterinary staff to be better prepared to care for the special needs of rabbit patients as they are presented in increased frequency for veterinary care. Housing, nutrition,restraint, and recognizing illness are covered in detail. Descriptions of techniques for blood collection, oral medication administration, and injection sites are included. Preventive care recommendations for examinations from first visit to geriatric visits are outlined as well as indications for spaying and neutering. Also provided are lists that will aid the veterinary staff in providing instructions when the appointment is made, recommendations for boarding, surgical, and anesthetic considerations and clinical signs that are associated with pain in rabbits. PMID:15145392

  18. Pneumatic protection applied to an airbag for para-gliders

    NASA Astrophysics Data System (ADS)

    Raievski, V.; Valladas, G.

    1998-02-01

    We present a theory of pneumatic protection based on the laws of thermodynamics, elasticity and fluid mechanics. A general pneumatic protection system is made up of several communicating compartments, the differences in pressure of the compartments generating a transfer of mass and energy between them. The transfer offers interesting possibilities to improve the performance of the system. An example of this type of protection in aerial sport is the airbag for para-gliders, it is used in this paper to illustrate the theory. As the pressure in the airbag depends uniquely on its volume, the geometric model in the theory can be simplified. Experiments carried out with crash-test dummies equipped with sensors have confirmed the theoretical predictions.

  19. Performance characterization of pneumatic single pellet injection system

    SciTech Connect

    Schuresko, D.D.; Milora, S.L.; Hogan, J.T.; Foster, C.A.; Combs, S.K.

    1982-01-01

    The Oak Ridge National Laboratory single-shot pellet injector, which has been used in plasma fueling experiments on ISX and PDX, has been upgraded and extensively instrumented in order to study the gas dynamics of pneumatic pellet injection. An improved pellet transport line was developed which utilizes a 0.3-cm-diam by 100-cm-long guide tube. Pellet gun performance was characterized by measurements of breech and muzzle dynamic pressures and by pellet velocity and mass determinations. Velocities up to 1.4 km/s were achieved for intact hydrogen pellets using hydrogen propellant at 5-MPa breech pressure. These data have been compared with new pellet acceleration calculations which include the effects of propellant friction, heat transfer, time-dependent boundary conditions, and finite gun geometry. These results provide a basis for the extrapolation of present-day pneumatic injection system performance to velocities in excess of 2 km/s.

  20. Development of pneumatic thrust-deflecting powered-lift systems

    NASA Technical Reports Server (NTRS)

    Englar, R. J.; Nichols, J. H., Jr.; Harris, M. J.; Eppel, J. C.; Shovlin, M. D.

    1986-01-01

    Improvements introduced into the Circulation Control Wing/Upper Surface Blowing (CCW/USB) STOL concept (Harris et al., 1982) are described along with results of the full-scale static ground tests and model-scale wind tunnel investigations. Tests performed on the full-scale pneumatic thrust-deflecting system installed on the NASA QSRA aircraft have demonstrated that, relative to the original baseline configuration, a doubling of incremental thrust deflection due to blowing resulted from improvements that increased the blowing span and momentum, as well as from variations in blowing slot height and geometry of the trailing edge. A CCW/Over the Wing model has been built and tested, which was shown to be equivalent to the CCW/USB system in terms of pneumatic thrust deflection and lift generation, while resolving the problem of cruise thrust loss due to exhaust scrubbing on the wing upper surface.

  1. Liquid-metal dip seal with pneumatic spring

    DOEpatents

    Poindexter, Allan M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.

  2. Electromyographic changes in postmeniscectomy patients. Role of the pneumatic tourniquet.

    PubMed

    Weingarden, S I; Louis, D L; Waylonis, G W

    1979-03-23

    Delayed rehabilitation in postmeniscectomy patients may be due to a slowly resolving axonal compression syndrome secondary to the use of the pneumatic tourniquet. Twenty-five patients who underwent meniscectomy were examined to determine whether the pneumatic tourniquet used during the procedure caused a neurological dificit detectable by electromyography (EMG). Of these, 18 had postsurgical EMG changes that eventually resolved. Analysis of the data suggests a relationship between the occurrence of EMG abnormalities, the duration of the tourniquet inflation during surgery, and patient's recovery time. Quadricep muscle weakness after knee surgery has generally been attributed to disuse atrophy. In an attempt to prevent this problem, patients participate in a quadriceps exercise program, if possible, before surgery, with continuation after surgery. The persistence of weakness has been believed to be secondary to inadequate exercise. PMID:581679

  3. Nonlinear Vibrational Behaviour of an Elasto-Pneumatic Training Tool

    NASA Astrophysics Data System (ADS)

    Körner, Claudia; Hetzler, Hartmut; Seemann, Wolfgang

    This paper deals with the nonlinear vibrational response of a stepping-board with nonlinear elasto-pneumatic force elements. Experimental investigations often show too high vertical ground reaction forces (VGRF) between the test persons and the training tool during exercises. The goal of this contribution is to identify the main factors of the dynamical behaviour and thus the biomechanical impact on humans of this training tool. Therefore this paper presents a mechanical model in order to investigate the interaction between the nonlinear behaviour of the board and the athlete. The multiphysical modelling consists of the linear-elastic structural stiffness part and the nonlinear part due to the pneumatic components. This leads to a nonlinear ordinary differential equation.

  4. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  5. Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy

    PubMed Central

    Zhang, Lin; Zhou, Yiwu

    2015-01-01

    Abstract Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before. We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output. This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism. PMID:26222867

  6. Evaluation of the pneumatic tube system for transportation of packed red cell units

    PubMed Central

    Dhar, Supriya; Basu, Sabita; Chakraborty, Subhosmito; Sinha, Subir

    2015-01-01

    Background: Pneumatic tube system (PTS) is commonly used in hospital settings to transport blood samples to diagnostic laboratories. At our blood center, we receive blood requisitions via the PTS, but units are carried to the ward by human courier. Recently we considered using the PTS for transporting blood units. Since, there are reports of hemolysis in blood samples sent through the PTS, we evaluated this system for transporting red cell units. Aims: The aim was to assess the effect of PTS transport on the quality of packed red cell units. Materials and Methods: A total of 50 red blood cells units (RBC), (25 non-irradiated and 25 irradiated) were subjected to transportation through the PTS. The control arm in the study was age-matched RBC units not subjected to PTS transport. Each RBC unit was evaluated for hemoglobin (Hb), lactate dehydrogenase, potassium and plasma hemoglobin (Hb). The paired t-test was used to compare these parameters, and the P value was calculated. Results and Conclusion: The percentage of hemolysis after transportation through PTS was below the recommended guidelines. Delivery of the blood unit to the wrong station, bags lying unattended at the destination were few of the problems that had to be addressed. To conclude, though the PTS is a safe means of transporting blood products with reduction in the turn-around-time, it must be validated before use. PMID:26420944

  7. Biodegradable fixation of rabbit osteotomies.

    PubMed

    Vainionpää, S; Vihtonen, K; Mero, M; Pätiälä, H; Rokkanen, P; Kilpikari, J; Törmälä, P

    1986-06-01

    Osteotomies of the tibial diaphysis were operatively fixed with biodegradable implants in 44 rabbits. Polyglycolic acid (PGA)/polylactic acid (PLA) copolymer implants reinforced with 7 per cent carbon fibre and overlaid with gold were used in 24 rabbits. Poly-beta-hydroxy butyric acid (PHBA) with carbon fibre reinforcement and gold surfacing were used in 20 rabbits. No external support was used. Unsatisfactory results were achieved with the PGA/PLA copolymer implants. Better results were achieved in 15 out of 20 rabbits whose osteotomies were fixed with carbon fibre-reinforced PHBA implants. PMID:3739665

  8. Comprehensive integration of homogeneous bioassays via centrifugo-pneumatic cascading.

    PubMed

    Godino, Neus; Gorkin, Robert; Linares, Ana V; Burger, Robert; Ducrée, Jens

    2013-02-21

    This work for the first time presents the full integration and automation concept for a range of bioassays leveraged by cascading a centrifugo-pneumatic valving scheme to sequentially move several liquids through shared channel segments for multi-step sample preparation into the detection zone. This novel centrifugo-pneumatic liquid handling significantly simplifies system manufacture by obviating the need for complex surface functionalization procedures or hybrid material integration, as it is common in conventional valving methods such as capillary burst valves or sacrificial valves. Based on the centrifugo-pneumatic valving scheme, this work presents a toolkit of operational elements implementing liquid loading/transfer, metering, mixing and sedimentation in a microstructured polymer disc. As a proof of concept for the broad class of homogeneous bioassays, the full integration and automation of a colorimetric nitrate/nitrite test for the detection of clinically relevant nitric oxide (NO) in whole blood is implemented. First, 40 μL of plasma is extracted from a 100 μL sample of human blood, incubated for one hour with the enzymatic mixture (60 μL), and finally reacted with 100 μL of colorimetric (Greiss) reagents. Following just a single loading phase at the beginning of the process, all of these steps are automated through the centrifugo-pneumatic cascade with a high level of flow control and synchronization. Our system shows good correlation with controls up to 50 μM of nitrate, which adequately covers the healthy human range (4 to 45.3 μM). PMID:23250328

  9. A pneumatic sample changer for gamma-ray spectroscopy

    USGS Publications Warehouse

    Massoni, C.J.; Fones, R.V.; Simon, F.O.

    1973-01-01

    A gravity-feed, pneumatic-ejection sample changer has been developed. The changer is suitable for both flat and well-type detectors and permits the continuous use of gamma-ray spectroscopy equipment 24 h a day, 7 days a week. The electronic circuitry has a fail-safe feature which stops the operation of the changer if a malfunction occurs. ?? 1973 The American Institute of Physics.

  10. Electric versus pneumatic power in hand prostheses for children.

    PubMed

    Plettenburg, D H

    1989-01-01

    Most externally powered hand prostheses for children with a unilateral congenital below-elbow amputation are myoelectrically controlled. All of them are electrically powered. Despite the success of fitting children with this kind of prostheses, there are some disadvantages: prosthetic weight is high, operating speed is low, the system is vulnerable and its size prohibits fitting it to patients with a long fore-arm stump. It will be shown that pneumatic power can overcome most of these disadvantages. PMID:2733004

  11. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  12. Characterization of sprays for thermo-stabilized pneumatic nebulizer.

    PubMed

    Ochowiak, M; Doligalski, M; Broniarz-Press, L; Matuszak, M; Gościniak, A

    2016-03-31

    The research presents the nebulizer spray chamber temperature controller responsible for controlling temperature of aerosol produced as a result of nebulizing process. The motivation to make an attempt to improve modern pneumatic devices was the shortage of this kind of apparatuses on the market allowing the production of thermos aerosol. A designed temperature controlling system for pneumatic nebulizers aims at increasing and stabilizing temperature of produced aerosols and increasing aerosol therapy safety. The system is intended for producing aerosol in the process of pneumatic nebulization with the temperature similar to that of the human body. Experiments that were carried out confirmed good performance of the device. It was proved that with the increase of temperature the amount of big droplets fall and the entire spectrum of the droplet diameter moves towards smaller droplet diameter values. Reduction of liquid viscosity related to the increase of temperature leads to the reduction of droplet diameter and, as a result, the reduction of the Sauter mean diameter value. PMID:26825254

  13. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  14. Design, modeling and fabrication of a constant flow pneumatic micropump

    NASA Astrophysics Data System (ADS)

    Inman, Walker; Domansky, Karel; Serdy, James; Owens, Bryan; Trumper, David; Griffith, Linda G.

    2007-05-01

    This paper characterizes a bi-directional pneumatic diaphragm micropump and presents a model for performance of an integrated fluidic capacitor. The fluidic capacitor is used to convert pulsatile flow into a nearly continuous flow stream. The pump was fabricated in acrylic using a CNC mill. The stroke volume of the pump is ~1 µL. The pump is self-priming, bubble tolerant and insensitive to changes in head pressure and pneumatic pressure within its operating range. The pump achieves a maximum flow rate of 5 mL min-1 against zero head pressure. With pneumatic pressure set to 40 kPa, the pump can provide flow at 2.6 mL min-1 against a head pressure of 25 kPa. A nonlinear model for the capacitor was developed and compared with experimental results. The ratio of the time constant of the capacitor to the cycle time of the pump is shown to be an accurate indicator of capacitor performance and a useful design tool.

  15. Evaluation of unsaturated zone air permeability through pneumatic tests

    USGS Publications Warehouse

    Baehr, Arthur L.; Hult, Marc F.

    1991-01-01

    Predicting the steady state distribution of air pressure in the unsaturated zone resulting from a pneumatic test provides a method for determining air-phase permeability. This technique is analogous to the inverse problem of well hydraulics; however, air flow is more complicated than ground water flow because of air compressibility, the Klinkenberg effect, variations in air density and viscosity that result from temperature fluctuations in the unsaturated zone and the possibility of inducing water movement during the pneumatic test. An analysis of these complicating factors reveals that, when induced water movement can be neglected, a linear version of the airflow equation can provide an appropriate approximation for the purpose of determining air-phase permeability. Two analytical solutions for steady state, two-dimensional, axisymmetric airflow to a single well partially screened in the unsaturated zone are developed. One solution applies where there is a stratum of relatively low air permeability, separating the stratum in which the well is completed, from the atmosphere. The other solution applies where there is no separating stratum between the domain and atmosphere. In both situations the water table forms the lower horizontal boundary. Applications of both solutions to determine air permeability from data collected during pneumatic tests are presented.

  16. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  17. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    NASA Technical Reports Server (NTRS)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  18. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia

    PubMed Central

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-01-01

    Abstract Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6–120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients’ clinical symptom scores were calculated before and at 6 to 36 months, 37 to 60 months, and >60 months after therapy. The influence of the patients’ age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36 months after therapy, 21 cases for 37 to 60 months, and 5 cases for >60 months, and the patients’ symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36 months remission rate was 85.7% (30/35), the 37 to 60 months rate was 61.9% (13/21), and the >60 months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations

  19. [Is pneumatic sample transport system also a carrier for microorganisms?].

    PubMed

    Alpat, Saygin Nayman; Ozgüneş, Ilhan; Aybey, Aşkin Derya; Ertem, Osman Turgut; Akşit, Filiz

    2009-07-01

    The purpose of this study was to evaluate the possible infection and contamination risk of the pneumatic system used in our hospital and to establish essential infection control measures. The study was conducted in a quaternary health care center with 1.000 bed capacity. A total of 614 specimens were taken 2 times weekly from the pneumatic transport system and its carriers at 22 wards, 5 intensive care units, 3 laboratories, 2 blood taking units, and pharmacy. Samples were also obtained from the fingertips of 33 subjects using the system, before and after contact with the carriers. A questionnaire that consisted of 8 questions was applied to 224 subjects who worked in those units, evaluating the degree of compliance to the obligations for the cleaning of the pneumatic system and carriers and their approach in case of visible pollution at the system. Bacterial growth was observed in 15.2% (45/296) of samples in the 1st week and 7.6% (18/238) of the samples in the 2nd week, making a total of 11.8% (63/534) bacterial growth. No growth was detected from the areas where the carriers were placed. Of these 69.8% were coagulase negative staphylococci, 11.1% diphteroids, 7.9% Acinetobacter Iwoffii, 4.8% Staphylococcus aureus, 4.8% Bacillus spp. and 1.6% Enterococcus durans. Acinetobacter baumannii and Aspergillus were detected at two fingertip samples taken before the contact with carriers, while again A. baumannii and Enterobacter cloacae were detected at the samples following contact. Moreover, 31.3% of the subjects noted that they cleaned the carriers only if any visible contamination was present. In addition, 14.3% reported that they have encountered broken or spilled up material in the system for more than 5 times, 10.3% reported that they followed the instructions in case of presence of infected material inside the carriers, 23.7% reported that they always washed their hands after any contact with the carriers, 9.8% noted that they always used gloves during contact

  20. Formulation of a minimum variance deconvolution technique for compensation of pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1990-01-01

    Increasingly, aircraft system designs require that aerodynamic parameters derived from pneumatic measurements be employed as control-system feedbacks. Such high frequency pressure measurements' accuracy is compromised by pressure distortion due to frictional attenuation and pneumatic resonance within the sensing system. A pneumatic distortion model is here formulated and reduced to a low-order state-variable model which retains most of the full model's dynamic characteristics. This reduced-order model is coupled with standard results from minimum variance estimation theory to develop an algorithm to compensate for pneumatic-distortion effects.

  1. Pathogenicity of rotavirus in rabbits.

    PubMed Central

    Thouless, M E; DiGiacomo, R F; Deeb, B J; Howard, H

    1988-01-01

    The role of rotavirus in diarrheal disease of rabbits was investigated, and a model for human rotavirus infection was established. Orogastric inoculation of 8- and 12-week-old New Zealand White rabbits with a rabbit strain of rotavirus (L:ALA:84) resulted in fecal shedding of virus for 6 to 8 days from 2 to 5 days after inoculation. Most rabbits exhibited diarrhea, coincident with the onset of viral shedding, which persisted for 2 to 4 days. Diarrhea was characterized by soft or fluid stools and fecal staining of the perineum. Inoculation of 3-week-old rabbits resulted in a briefer period of viral shedding and diarrhea of a milder nature. Histopathologic examination during the period of viral shedding revealed a mild, nonsuppurative enteritis. Inoculated rabbits exhibited antibodies in serum to rotavirus by enzyme-linked immunosorbent assay. Sham-inoculated or uninoculated rabbits maintained in the same cage or the same room with inoculated rabbits acquired rotavirus infection. The mild diarrheal disease which resulted with a rotavirus isolate from severe field cases suggests that cofactors were involved. Images PMID:2838507

  2. Neuromuscular lesions in restrained rabbits.

    PubMed

    Mendlowski, B

    1975-01-01

    Ten of 16 rabbits restrained 6 h daily for 35 days developed focal to diffuse degeneration of the sciatic nerves. Very small necrotic areas also were found in the skeletal muscles of seven of 16 rabbits, but the muscle lesions did not correlate with the nerve changes. PMID:180647

  3. Pulmonary pneumaticity in the postcranial skeleton of extant aves: a case study examining Anseriformes.

    PubMed

    O'Connor, Patrick M

    2004-08-01

    Anseriform birds were surveyed to examine how the degree of postcranial pneumaticity varies in a behaviorally and size-diverse clade of living birds. This study attempts to extricate the relative effects of phylogeny, body size, and behavioral specializations (e.g., diving, soaring) that have been postulated to influence the extent of postcranial skeletal pneumaticity. One hundred anseriform species were examined as the focal study group. Methods included latex injection of the pulmonary apparatus followed by gross dissection or direct examination of osteological specimens. The Pneumaticity Index (PI) is introduced as a means of quantifying and comparing postcranial pneumaticity in a number of species simultaneously. Phylogenetically independent contrasts (PICs) were used to examine the relationship between body size and the degree of postcranial pneumaticity throughout the clade. There is a high degree of similarity (i.e., clade-specificity) within most anseriform subgroups. As a whole, Anseriformes demonstrate no significant relationship between relative pneumaticity and body size, as indicated by regression analysis of body mass on PI. It is apparent, however, that many clades of diving ducks do exhibit lower PIs than their nondiving relatives. By exclusion of diving taxa from analyses, a significant positive slope is observed and the hypothesis of relatively higher pneumaticity in larger-bodied birds is only weakly supported. However, low correlations indicate that factors other than body size account for much of the variation observed in relative pneumaticity. Pneumaticity profiles were mapped onto existing phylogenetic hypotheses. A reduction in the degree of postcranial pneumaticity occurred independently in at least three anseriform subclades specialized for diving. Finally, enigmatic pneumatic features located in distal forelimb elements of screamers (Anhimidae) result from invasion of bone by a network of subcutaneous air sac diverticula spreading

  4. Gait Using Pneumatic Brace for End-Stage Knee Osteoarthritis.

    PubMed

    Kapadia, Bhaveen H; Cherian, Jeffrey Jai; Starr, Roland; Chughtai, Morad; Mont, Michael A; Harwin, Steven F; Bhave, Anil

    2016-04-01

    More than 20 million individuals in the United States are affected by knee osteoarthritis (OA), which can lead to altered biomechanics and excessive joint loading. The use of an unloader pneumatic brace with extension assist has been proposed as a nonoperative treatment modality that may improve gait mechanics and correct knee malalignment. We assessed the following parameters in patients who have knee OA treated with and without a brace: (1) changes in temporospatial parameters in gait; (2) knee range of motion, knee extension at heel strike, and foot placement; (3) knee joint moments and impulse; and (4) changes in dynamic stiffness and rate of change of knee flexion during midstance to terminal stance. This 2:1 prospective, randomized, single-blinded trial evaluated 36 patients (24 brace and 12 matching). OA knee patients were randomized to receive either a pneumatic unloader brace or a standard nonoperative treatment regimen as the matching cohort for a 3-month period. They underwent evaluation of gait parameters using a three-dimensional gait analysis system at their initial appointment and at 3 months follow-up. All the testing, pre- and postbracing were performed without wearing the brace to examine for retained effects. Treatment with the brace led to significant improvements versus standard treatment in various gait parameters. Patients in the brace group had improvements in walking speed, knee extension at heel strike, total range of motion, knee joint forces, and rate of knee flexion from midstance to terminal stance when compared with the matching cohort. Knee OA patients who used a pneumatic unloader brace for 3 months for at least 3 hours per day had significant improvements various gait parameters when compared with a standard nonoperative therapy cohort. Braced patients demonstrated gait-modifying affects when not wearing the brace. These results are encouraging and suggest that this device represents a promising treatment modality for knee OA that

  5. Forces associated with pneumatic power screwdriver operation: statics and dynamics.

    PubMed

    Lin, Jia-Hua; Radwin, Robert G; Fronczak, Frank J; Richard, Terry G

    2003-10-10

    The statics and dynamics of pneumatic power screwdriver operation were investigated in the context of predicting forces acting against the human operator. A static force model is described in the paper, based on tool geometry, mass, orientation in space, feed force, torque build up, and stall torque. Three common power hand tool shapes are considered, including pistol grip, right angle, and in-line. The static model estimates handle force needed to support a power nutrunner when it acts against the tightened fastener with a constant torque. A system of equations for static force and moment equilibrium conditions are established, and the resultant handle force (resolved in orthogonal directions) is calculated in matrix form. A dynamic model is formulated to describe pneumatic motor torque build-up characteristics dependent on threaded fastener joint hardness. Six pneumatic tools were tested to validate the deterministic model. The average torque prediction error was 6.6% (SD = 5.4%) and the average handle force prediction error was 6.7% (SD = 6.4%) for a medium-soft threaded fastener joint. The average torque prediction error was 5.2% (SD = 5.3%) and the average handle force prediction error was 3.6% (SD = 3.2%) for a hard threaded fastener joint. Use of these equations for estimating handle forces based on passive mechanical elements representing the human operator is also described. These models together should be useful for considering tool handle force in the selection and design of power screwdrivers, particularly for minimizing handle forces in the prevention of injuries and work related musculoskeletal disorders. PMID:12933078

  6. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    SciTech Connect

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao; Jambovane, Sachin R.; Kelly, Ryan T.

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

  7. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  8. Model free control for differential pneumatic pistons: experimental comparison

    NASA Astrophysics Data System (ADS)

    Weist, Jens; Arteaga, Marco A.; de la Cruz, Leonardo R.; Hebisch, Holger

    2011-01-01

    PID controllers are widely used in industry. While this may be appropriate for many systems, eventually a more complex or reliable algorithm has to be designed to improve performance. Common praxis is to take advantage either of physical properties (e.g. passivity) or of a mathematical model. For this last case it may prove to be hard to get an accurate description of the system dynamics. In this article we experimentally analyse the behaviour of pneumatic actuators by employing control algorithms available in the literature with little or no model information at all, including an adaptation of a robot control law which is shown to work very well for the test bed.

  9. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... car tires to meet safety criteria similar to those for new pneumatic passenger car tires....

  10. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be accomplished... allowable working pressure of the vessel to permit examination. (e) Pressure vessels pneumatically tested... testing of welded pressure vessels shall be permitted only for those units which are so designed...

  11. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be accomplished... allowable working pressure of the vessel to permit examination. (e) Pressure vessels pneumatically tested... testing of welded pressure vessels shall be permitted only for those units which are so designed...

  12. A quantitative method for the evaluation of three-dimensional structure of temporal bone pneumatization.

    PubMed

    Hill, Cheryl A; Richtsmeier, Joan T

    2008-10-01

    Temporal bone pneumatization has been included in lists of characters used in phylogenetic analyses of human evolution. While studies suggest that the extent of pneumatization has decreased over the course of human evolution, little is known about the processes underlying these changes or their significance. In short, reasons for the observed reduction and the potential reorganization within pneumatized spaces are unknown. Technological limitations have limited previous analyses of pneumatization in extant and fossil species to qualitative observations of the extent of temporal bone pneumatization. In this paper, we introduce a novel application of quantitative methods developed for the study of trabecular bone to the analysis of pneumatized spaces of the temporal bone. This method utilizes high-resolution X-ray computed tomography (HRXCT) images and quantitative software to estimate three-dimensional parameters (bone volume fractions, anisotropy, and trabecular thickness) of bone structure within defined units of pneumatized spaces. We apply this approach in an analysis of temporal bones of diverse but related primate species, Gorilla gorilla, Pan troglodytes, Homo sapiens, and Papio hamadryas anubis, to illustrate the potential of these methods. In demonstrating the utility of these methods, we show that there are interspecific differences in the bone structure of pneumatized spaces, perhaps reflecting changes in the localized growth dynamics, location of muscle attachments, encephalization, or basicranial flexion. PMID:18715622

  13. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials...

  14. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials...

  15. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials...

  16. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials...

  17. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  18. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  19. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  20. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  1. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  2. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... design temperature (see UG-21 of section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01-1)). In no case shall the pneumatic test pressure exceed one and one... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be...

  3. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... design temperature (see UG-21 of section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01-1)). In no case shall the pneumatic test pressure exceed one and one... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be...

  4. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... design temperature (see UG-21 of section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01-1)). In no case shall the pneumatic test pressure exceed one and one... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be...

  5. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... intended function under any normal system operating temperature or pressure, and (c) Means to indicate to... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection...

  6. Intracranial volume in craniosynostotic rabbits.

    PubMed

    Mooney, M P; Burrows, A M; Wigginton, W; Singhal, V K; Losken, H W; Smith, T D; Dechant, J; Towbin, A; Cooper, G M; Towbin, R; Siegel, M I

    1998-05-01

    Although craniosynostosis alters brain growth direction resulting in compensatory changes in the neurocranium, it has been suggested that such compensations occur with little reduction in intracranial volume (ICV). This hypothesis was tested in a rabbit model with nonsyndromic, familial coronal suture synostosis. Cross-sectional three-dimensional computed tomographic head scans were obtained from 79 rabbits (25 normal, 28 with delayed-onset synostosis, and 26 with early-onset synostosis) at 25, 42, and 126 days of age. Intracranial contents were reconstructed and indirect ICV was calculated. Results revealed that by 25 days of age the intracranial contents from early-onset synostosed rabbit skulls showed rostral (anterior) constrictions and a "beaten copper" morphology in the parietal and temporal regions compared with the other two groups. These deformities increased in severity with age. Quantitatively, ICV was significantly reduced (P < 0.05) by 7% in rabbits with early-onset synostosis compared with both control rabbits and rabbits with delayed-onset synostosis at 25 days of age. By 126 days of age, ICV in rabbits with synostosis was significantly reduced (p < 0.05) by 11% in early-onset synostosis and by 8% in delayed-onset synostosis compared with normal rabbits. Results suggest that in rabbits with uncorrected craniosynostosis, compensatory changes in the neurocranium were not adequate to allow normal expansion of the neurocapsular matrix. Further research is needed to determine if ICV reduction is correlated with cerebral atrophy or cerebral spinal fluid (i.e., ventricular or subarachnoid) space compression in this model. PMID:9693554

  7. Frictional properties of lubrication greases with the addition of nickel nanoparticles in pneumatic cylinder

    NASA Astrophysics Data System (ADS)

    Chang, Ho; Lan, Chou-Wei; Guo, Jia-Bin

    2011-12-01

    This paper studies the influence of addition of 100 nm diameter nickel nano-particles on the friction properties of synthetic grease (Li base, VG100) in pneumatic cylinder. The friction force test of pneumatic cylinder equipment measures the frictional force between seal and cylinder bore in pneumatic cylinders. The lubricants with addition of nickel nano-particles were used for lubricating the contact interface between seal and cylinder bore. The friction force test equipment employ a load cell force sensor to measure the friction force between seals and cylinder bores. Results obtained from experimental tests are compared to determine the friction force between seals and cylinder bore in pneumatic cylinders. The study leads to the conclusion that the addition of nickel nano-particles to synthetic grease results in a decrease in friction force between seals and cylinder bores in pneumatic cylinder. This tribological behavior is closely related to the deposition of nano-particles on the rubbing surfaces

  8. The pneumatization patterns of the roof of the parapharyngeal space in CBCT

    PubMed Central

    Andrei, Felicia; Motoc, Andrei Gheorghe Marius; Jianu, Adelina Maria; Rusu, Mugurel Constantin; Loreto, Carla

    2012-01-01

    Introduction The rhinopharynx and the parapharyngeal space (PPS) are complex anatomical territories located beneath the skull base. Thorough knowledge of the complex anatomy of the PPS is essential in treatment of pathologies such as parapharyngeal abscesses. The roof of the PPS is overlooked in anatomy. It was hypothesized that the pneumatization pattern of the PPS roof is individually variable, as determined by the variable pneumatization patterns of the sphenoid and temporal bones. The study was aimed at assessing the anatomy of the PPS roof in CBCT. Methods The present study was performed retrospectively on a group of 35 subjects (37.1% males) evaluated by CBCT for various dental procedures. Results The mean age of the group was 37.9 (SD: 14.2, range: 18 to 61). The major bony landmarks of the PPS roof were: the petrous apex with the carotid canal, the jugular foramen, the foramen lacerum, the sphenopetrosal fissure or suture, and the root of the pterygoid process. Variable patterns of pneumatization were determined by the petrous apex air cells and the pterygoalar recess of the sphenoidal sinus. As related to the individually pattern of pneumatization, the following types of the PPS roof were defined: (i) type 1 – not pneumatized PPS roof; (ii) type 2 – sphenoidal but not petrosal pneumatization of the PPS roof; (iii) type 3 – petrosal but not sphenoidal pneumatization of the PPS roof; (iv) type 4 – sphenoidal and petrosal pneumatizations of the PPS roof. Discussion Although on the left side the degree of pneumatization was higher than on the right side, no statistical differences were recorded (p > 0.05). The pattern of pneumatizations in the PPS roof should be assessed when PPS involvement in otitis or sinusitis is considered. PMID:24432276

  9. Energy spectra of the pneumatically positioned neutron sources at LLNL's Hazards control standards and calibration facility

    SciTech Connect

    Thorngate, J.H.

    1987-06-15

    The Hazards Control Department of Lawrence Livermore National Laboratory maintains a Standards and Calibration Laboratory that includes three neutron sources (two /sup 252/Cf and one /sup 238/PuBe that can be positioned pneumatically for irradiations. Ten moderators exist to modify the neutron energy spectra produced by these sources. The thicknesses and materials of these moderators are: 25-cm water; 5-, 10-, 15-, and 25-cm heavy water; 20-cm aluminum; and 2-, 5-, 10-, and 15-cm polyethylene. We used a multisphere spectrometer to measure the neutron spectra at 2 m from both the PuBe source and the smaller Cf source, with the sources bare, and in all of the moderators. These data were reduced in 25 energy groups ranging from 0.25 eV to 16 MeV. Except for the 15-m polyethylene moderator, we also made measurements using a liquid-scintillator fast-neutron spectrometer. These data were reduced in 0.1-MeV increments from 0.5 to 12.5 MeV. Spectra from the measurements and from independent calculations are presented in tabular and graphic form. Dosimetric values, calculated from both the measured and calculated spectra, are also presented.

  10. Development of an Air Pneumatic Suspension System for Transtibial Prostheses

    PubMed Central

    Pirouzi, Gholamhossein; Osman, Noor Azuan Abu; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Wan Abas, Wan A. B.

    2014-01-01

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded. PMID:25207872

  11. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-01

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices. PMID:24145429

  12. Pneumatic oscillator circuits for timing and control of integrated microfluidics

    PubMed Central

    Duncan, Philip N.; Nguyen, Transon V.; Hui, Elliot E.

    2013-01-01

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices. PMID:24145429

  13. Prognostics for Ground Support Systems: Case Study on Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Goebel, Kai

    2011-01-01

    Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.

  14. Performance analysis and experiment validation of a pneumatic vibration isolator

    NASA Astrophysics Data System (ADS)

    Yang, Yuanyuan; Tan, Jiubin; Wang, Lei; Zhou, Tong

    2015-02-01

    A performance analysis and experiment validation of a pneumatic vibration isolator (PVI) that applied in the wafer stage of lithography is proposed in this work. The wafer stage of lithography is a dual-stage actuator system, including a long-stroke stage (LS) and a short-stroke stage (SS). In order to achieve the nanometer level positioning the isolator is designed to reduce the transmission of LS excitations to SS. In addition, considering the SS with six degrees of freedom and required to keep a strict constant temperature environment, the isolator need to have two functions, including the decoupling for vertical to horizontal and gravity compensation. In this isolator, a biaxial hinge was designed to decouple vertical rotation freedom, and a gas bearing was designed to decouple horizontal motion. The stiffness and damping of the pneumatic vibration isolator were analyzed. Besides, an analysis of the natural frequency and vibration transmissibility of the isolator is presented. In the end, the results show that vibration transmission is reduced significantly by the isolator and natural frequency can be lower than 0.6 Hz. This means that experimental results accord with the prediction model.

  15. Empirical modeling of dynamic behaviors of pneumatic artificial muscle actuators.

    PubMed

    Wickramatunge, Kanchana Crishan; Leephakpreeda, Thananchai

    2013-11-01

    Pneumatic Artificial Muscle (PAM) actuators yield muscle-like mechanical actuation with high force to weight ratio, soft and flexible structure, and adaptable compliance for rehabilitation and prosthetic appliances to the disabled as well as humanoid robots or machines. The present study is to develop empirical models of the PAM actuators, that is, a PAM coupled with pneumatic control valves, in order to describe their dynamic behaviors for practical control design and usage. Empirical modeling is an efficient approach to computer-based modeling with observations of real behaviors. Different characteristics of dynamic behaviors of each PAM actuator are due not only to the structures of the PAM actuators themselves, but also to the variations of their material properties in manufacturing processes. To overcome the difficulties, the proposed empirical models are experimentally derived from real physical behaviors of the PAM actuators, which are being implemented. In case studies, the simulated results with good agreement to experimental results, show that the proposed methodology can be applied to describe the dynamic behaviors of the real PAM actuators. PMID:23871151

  16. The cottontail rabbits of Virginia

    USGS Publications Warehouse

    Llewellyn, L.M.; Handley, C.O.

    1945-01-01

    Five races of cottontail rabbits belonging to three species occur in Virginia. One of them, the Mearns cottontail (Sylvilagus floridanus mearnsi), is reported here for the first time. It occurs in six southwestern counties of the state, while the eastern cottontail (S. f. mallurus) occurs in the remainder of the state with the exception of Smith and Fishermans islands off the eastern coast of Cape Charles, where it is replaced by Hitchens cottontail (S. f. hitchensi). The New England cottontail (S. transitionalis) is found on the higher mountain peaks, above 3000 feet, and the swamp rabbit (S. palustris) occurs in the Dismal Swamp region of southeastern Virginia.....The height of the breeding season for the eastern cottontail in Virginia is March and April, but breeding continues through the entire year except in December and January. The average litter size based on embryo counts was 4.7. The sex ratio of 234 specimens from all parts of the state, taken mostly in the December to February period, was 53 males to 47 females. That of a group of 145 rabbits live-trapped at Blacksburg during February and Marchwas 58 males to 42 females. The figures show that males are more active than females during the winter months, and therefore are more easily taken then....In transplanting cottontails from one section of the state to another, it is recommended that only cottontails of the same race as those originally present in the region being restocked be released there....Tularemia is not a common disease among rabbits in Virginia, but the rabbit ticks are often carriers of the disease and may transmit it to rabbits. Rabbit ticks are also found to be carriers of Rocky Mountain fever and American Q. fever. After the ticks drop off the rabbits to hibernate in the ground, which is likely to occur during mid-winter in Virginia, there is relatively little danger of humans contracting tularemia by contact with rabbits. Present laws in Virginia which prohibit rabbit hunting until the

  17. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved. PMID:26726680

  18. Induction and prevention of virus-associated malignant lymphoma by serial transmission of EBV-related virus from cynomolgus by blood transfusion in rabbits.

    PubMed

    Koirala, Tirtha Raj; Hayashi, Kazuhiko; Jin, Zaishun; Onoda, Sachiyo; Tanaka, Takehiro; Oda, Wakako; Ichimura, Koichi; Ohara, Nobuya; Oka, Takashi; Yamada, Masao; Yoshino, Tadashi

    2004-04-01

    Epstein-Barr virus (EBV)-related herpesvirus (Si-IIA-EBV) was serially transmitted for 3 passages from rabbit to rabbit of the opposite sex by blood transfusion, which subsequently induced virus-associated rabbit lymphomas. The virus could be transmitted by transfusion with 15-20 ml of whole blood (7/7) or irradiated blood (1/6) from the EBV-related virus-infected rabbits, but there was no transmission with transfusion of cell-free plasma (0/6) from the infected rabbits. Passive anti-EBV-VCA IgG (x 20 approximately x 10) titers decreased during the first 1-2 weeks in the transfused rabbits. The virus-transmitted rabbits showed a gradual increase in antibody titers ranging from peak titers of x 640 to x 2560 after 3 weeks of transfusion. The recipient origin of malignant lymphoma that developed in the first rabbit transfused by infected blood was confirmed by chromosomal analysis. This rabbit model thus shows that EBV-related herpesvirus is serially transmissible by blood transfusion and that transmission can not be completely prevented by irradiation of blood, but removal of blood cells is the best way to prevent transmission of EBV-related virus. Therefore, this animal model provides a convenient in vivo system for studies of the prevention and therapy of transfusion-related transmission of EBV and EBV-associated lymphoproliferative diseases in immunocompromised human beings. PMID:15255507

  19. Rabbit model of rotavirus infection.

    PubMed Central

    Conner, M E; Estes, M K; Graham, D Y

    1988-01-01

    A new small animal model was developed to study parameters of rotavirus infections, including the active immune response. Seronegative New Zealand White rabbits (neonatal to 4 months old) were inoculated orally with cultivatable rabbit rotavirus strains Ala, C11, and R2 and with the heterologous simian strain SA11. The course of infection was evaluated by clinical findings, virus isolation (plaque assay and enzyme-linked immunosorbent assay), and serologic response. All four strains of virus were capable of infecting rabbits as determined by isolation of infectious virus from intestinal contents or fecal samples, by seroconversion, or by a combination of these methods. The responses differed depending on the virus strain used for inoculation. Rabbits remained susceptible to primary infection to at least 16 weeks of age (upper limit examined). Virus excretion in intestinal contents was detected from 6 h to 7 days postinoculation. RNA electropherotypes of inocula and viruses isolated from rabbits were the same in all samples tested. Transmission of Ala virus and R2 virus but not SA11 virus from inoculated animals to uninoculated controls also occurred. In a challenge experiment with Ala virus, 74- and 90-day-old rabbits were rechallenged with Ala 5 weeks after a primary infection with Ala. Virus was excreted in feces from 2 to 8 days after the primary infection but was not excreted after challenge. These results indicate that the rabbit provides an ideal model to investigate both the primary and secondary active immune responses to rotavirus infections and to evaluate candidate vaccines. Images PMID:2833612

  20. Irradiation effect of polarization direction and intensity of semiconductor laser on injured peripheral nerve

    NASA Astrophysics Data System (ADS)

    Guo-Xin, Xiong; Lei-lei, Xiong

    2016-08-01

    To investigate the irradiation effect of polarization direction and the intensity of a semiconductor laser on the injured peripheral nerve in rabbits, the model of the injured common peroneal nerve was established, the L5,6 spinal segments of the rabbits were irradiated, a uniform rotating polarizer was placed at the laser output which made the polarization direction and intensity of the output laser change according to the 80 Hz cosine law. The experimental results show that irradiating the spinal segment of injured nerves in rabbits with this changeable semiconductor laser can significantly promote the regeneration of injured peripheral nerves and the function recovery.

  1. The qualitative assessment of pneumatic actuators operation in terms of vibration criteria

    NASA Astrophysics Data System (ADS)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.

  2. Preliminary measurements on heat balance in pneumatic tires

    NASA Technical Reports Server (NTRS)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  3. The role of particle collisions in pneumatic transport

    NASA Technical Reports Server (NTRS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-01-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  4. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  5. Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels

    NASA Astrophysics Data System (ADS)

    Wang, Chih-Hao; Lee, Gwo-Bin

    2006-02-01

    This study presents a novel pneumatic micropump featuring a serpentine-shape (S-shape) microchannel. Fluid is driven through the device by the hydrodynamic pressure generated by the peristaltic action of membranes located at the intersections of the fluidic microchannel and the S-shape microchannel. The pneumatic micropump is fabricated in PDMS (polydimethylsiloxane) using MEMS (micro-electro-mechanical-systems)-based techniques. The micropump provides an improved pumping rate and is controlled using a single electromagnetic valve (EMV) switch. The experimental results reveal that the pumping rate can be increased by increasing the operational frequency of the EMV, the pressure of the externally supplied compressed air or the number of membranes. As the compressed air travels along the S-shape microchannel, it causes the membranes to deflect. The time-phased deflection of successive membranes along the microchannel length generates a peristaltic effect which drives the fluid along the microfluidic channel. The maximum attainable pumping rate is influenced by the time interval between the deflections of adjacent membranes, and is therefore affected by the geometric characteristics of the serpentine microchannel. The back pressure of the serpentine-shape micropump is measured at a fixed peak frequency to prove its ability to overcome the fluidic resistance. The optimum operating conditions and geometric parameters of the micropump are verified experimentally. It is found that the maximum pumping rate is 7.43 µl min-1 and is provided by a micropump with seven membranes actuated by 20 psi air pressure and 9 Hz operational frequency. The preliminary results of the current paper were presented at the 2005 IEEE International Conference on Robotics and Biomimetics (IEEE ROBIO 2005), Hong Kong SAR, 29 June-03 July 2005.

  6. Differential Fault Analysis of Rabbit

    NASA Astrophysics Data System (ADS)

    Kircanski, Aleksandar; Youssef, Amr M.

    Rabbit is a high speed scalable stream cipher with 128-bit key and a 64-bit initialization vector. It has passed all three stages of the ECRYPT stream cipher project and is a member of eSTREAM software portfolio. In this paper, we present a practical fault analysis attack on Rabbit. The fault model in which we analyze the cipher is the one in which the attacker is assumed to be able to fault a random bit of the internal state of the cipher but cannot control the exact location of injected faults. Our attack requires around 128 - 256 faults, precomputed table of size 241.6 bytes and recovers the complete internal state of Rabbit in about 238 steps.

  7. Teratology studies in the rabbit.

    PubMed

    Allais, Linda; Reynaud, Lucie

    2013-01-01

    The rabbit is generally the non-rodent species or second species after the rat recommended by the regulatory authorities and is part of the package of regulatory reproductive studies for the detection of potential embryotoxic and/or teratogenic effects of pharmaceuticals, chemicals, food additives, and other compounds, including vaccines (see Chapters 1-7).Its availability, practicality in housing and in mating as well as its large size makes the rabbit the preferred choice as a non-rodent species. The study protocols are essentially similar to those established for the rat (Chapter 9), with some particularities. The study designs are well defined in guidelines and are relatively standardized between testing laboratories across the world.As for the rat, large litter sizes and extensive background data in the rabbit are valuable criteria for an optimal assessment of in utero development of the embryo or fetus and for the detection of potential external or internal fetal malformations. PMID:23138902

  8. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  9. European Rabbits as Reservoir for Coxiella burnetii

    PubMed Central

    González-Barrio, David; Maio, Elisa; Vieira-Pinto, Madalena

    2015-01-01

    We studied the role of European rabbits (Oryctolagus cuniculus) as a reservoir for Coxiella burnetii in the Iberian region. High individual and population seroprevalences observed in wild and farmed rabbits, evidence of systemic infections, and vaginal shedding support the reservoir role of the European rabbit for C. burnetii. PMID:25988670

  10. Costs and benefits of pneumatic collection in three specific New York City cases

    SciTech Connect

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-15

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of