Science.gov

Sample records for pneumatic irradiation rabbit

  1. Automated pneumatic transfer irradiation system for delayed neutron counting

    SciTech Connect

    Heifer, Paul G.; Millard, Hugh T. Jr.; Zermane, Albert J

    1982-07-01

    The Geological Survey TRIGA Reactor has been used for uranium and thorium neutron activation analysis by delayed neutron counting for the past eleven years. As the requirements for analysis increased the original General Atomic pneumatic system was upgraded in several stages. By 1979 we had reached the practical limits of safe through-put for that system and a new pneumatic transfer system was built. A single large Roots type blower is used to drive four individual transfer tubes simultaneously (two termini in the core and two outside the reflector). A microprocessor controls the operation and is paced by a minicomputer, which is also used to collect and reduce the counting data. Two irradiations and counting cycles are performed on each sample, one in the core, a Cd-lined terminus for thorium, and one in the reflector mounted terminus for uranium. Video displays at both the reactor console and the pneumatic system operating station indicate the status of the system and the locations of the samples at all times. This highly automated system is capable of 1,200 irradiations for delayed neutron counting in a 10 hour day, and, in addition, incorporates programmable versatility for other irradiation-counting experiments, and provides a high degree of reactor and radiological safety with only remote operator attention. (author)

  2. Pneumatics.

    ERIC Educational Resources Information Center

    Engelbrecht, Nancy; And Others

    This unit on pneumatics, for use in postsecondary programs, is organized in eight sections. Each section consists of information sheets with line drawings and multiple-choice questions for each topic in the sections. Answers are provided at the back of the book. The following topics are covered: (1) introduction--pressure, principles of gases,…

  3. Acute microwave irradiation and cataract formation in rabbits and monkeys.

    PubMed

    Kramar, P; Harris, C; Emery, A F; Guy, A W

    1978-09-01

    Rabbits and monkeys were irradiated in the near field of a cavity-backed 2450 MHz resonant slot radiator, to determine the cataractogenic threshold. Rabbits developed cataracts at incident "apparent" power densities of 180 mW/cm2 (E2/120 pi, where E=rms/electric field strength). Monkeys sustained facial burns, but no lens damage, even at incident "apparent" power densities of 500 mW/cm2. These results were substantiated by computer thermal models. PMID:108401

  4. Phase separation of X-irradiated lenses of rabbit

    SciTech Connect

    Clark, J.I.; Giblin, F.J.; Reddy, V.N.; Benedek, G.B.

    1982-02-01

    The phase separation temperature (Tcat) was studied as a function of time (age) after the administration of a single dose of radiation (2000 rad), which induces cataract in the rabbit lens. In the normal unirradiated lens, Tcat decreases linearly with age at a rate (DTcat/dt) approximately 2.2 degrees/week. In the irradiated lens, Tcat initially decreases with age much less than the normal lens, then rises sharply with age at the time of the appearance of opacity in the living rabbit eye. We suggest that the phase separation temperature may serve as a sensitive and early indicator of cataractogenic processes in the lens.

  5. Late degeneration in rabbit tissues after irradiation by heavy ions

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Keng, P. C.; Lee, A. C.; Su, C. M.; Bergtold, D. S.

    1980-01-01

    Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

  6. Disposal rabbit

    DOEpatents

    Lewis, L.C.; Trammell, D.R.

    1983-10-12

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  7. Disposable rabbit

    DOEpatents

    Lewis, Leroy C.; Trammell, David R.

    1986-01-01

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  8. Gamma-Irradiated Sterile Cornea for Use in Corneal Transplants in a Rabbit Model

    PubMed Central

    Yoshida, Junko; Heflin, Thomas; Zambrano, Andrea; Pan, Qing; Meng, Huan; Wang, Jiangxia; Stark, Walter J.; Daoud, Yassine J.

    2015-01-01

    Purpose: Gamma irradiated corneas in which the donor keratocytes and endothelial cells are eliminated are effective as corneal lamellar and glaucoma patch grafts. In addition, gamma irradiation causes collagen cross inking, which stiffens collagen fibrils. This study evaluated gamma irradiated corneas for use in corneal transplantations in a rabbit model comparing graft clarity, corneal neovascularization, and edema. Methods: Penetrating keratoplasty was performed on rabbits using four types of corneal grafts: Fresh cornea with endothelium, gamma irradiated cornea, cryopreserved cornea, and fresh cornea without endothelium. Slit lamp examination was performed at postoperative week (POW) one, two, and four. Corneal clarity, edema, and vascularization were graded. Confocal microscopy and histopathological evaluation were performed. A P < 0.05 was statistically significant. Results: For all postoperative examinations, the corneal clarity and edema were statistically significantly better in eyes that received fresh cornea with endothelium compared to the other three groups (P < 0.05). At POW 1, gamma irradiated cornea scored better than the cryopreserved and fresh cornea without endothelium groups in clarity (0.9 vs. 1.5 and 2.6, respectively), and edema (0.6 vs. 0.8 and 2.0, respectively). The gamma irradiated corneas, cryopreserved corneas and the fresh corneas without endothelium, developed haze and edema after POW 2. Gamma irradiated cornea remained statistically significantly clearer than cryopreserved and fresh cornea without endothelium during the observation period (P < 0.05). Histopathology indicated an absence of keratocytes in gamma irradiated cornea. Conclusion: Gamma irradiated corneas remained clearer and thinner than the cryopreserved cornea and fresh cornea without endothelium. However, this outcome is transient. Gamma irradiated corneas are useful for lamellar and patch grafts, but cannot be used for penetrating keratoplasty. PMID:26180475

  9. Kinetics of (/sup 14/C-5) 8-methoxypsoralen uptake by UVA irradiated and non-irradiated rabbit eye tissues

    SciTech Connect

    Malinin, G.I.; Glew, W.B.; Roberts, W.P.; Nigra, T.P.

    1981-05-01

    Total 8-methoxypsoralen (8-MOP) in intact and UVA irradiated rabbit eye tissues and its unaltered fraction in aqueous and eye lenses were determined over the 24 hours after i.v. injection of (/sup 14/C-5) and carrier 8-MOP at the concentration of 50 microCi and 5 mg/kg. No 8-MOP was detected at the end of 24 hours in intact and irradiated aqueous, vitreous and retina in contrast to one hour when the respective levels were congruent to 220, greater than 0 and congruent to 160 ng/g. Eye-plasma drug concentration ratios were less than 0.5 initially, but increased thereafter. While the average lens 8-MOP levels of congruent to 140 ng/g remained unchanged for 24 hours, no unaltered drug was detected beyond eight hours. Measurable amounts of label at the end of 24 hours also persisted in the cornea, iris, sclera and conjunctiva.

  10. The hematologic effects of low intensity 650 nm laser irradiation on hypercholesterolemia rabbits

    PubMed Central

    Wang, Hong; Deng, Juan; Tu, Wenjun; Zhang, Lin; Chen, Hongli; Wu, Xiaoguang; Li, Yingxin; Sha, Hong

    2016-01-01

    Purpose: To test the hematologic effects of low intensity 650 nm laser irradiation on hypercholesterolemia rabbits. Methods: Ten male big-eared rabbits were selected from hypercholesterolemia animal model-making and divided into model group and laser treatment groups. Five normal rabbits were selected as control group. Auricle root irradiation of 650 nm laser 100 mW in 30 min were applied on treatment group twice a day, treatment of 6 days in one week, 20 weeks course of treatment. Changes in blood lipid, microcirculation, rheological properties, and aggregation morphology of erythrocytes were observed every two weeks. Histopathological examination were performed in the end of experiments. Results: After 20 weeks’ treatment, triglyceride (TG), cholesterol (CHO), high density lipoprotein (HDL) and low density lipoprotein (LDL) of serum in hypercholesterolemia groups showed less changes in the first 4 weeks, butdifferent decreasing trends were shownin the next 16 weeks’ therapy. Erythrocytes aggregation of model groups showed rouleau state, while red blood cells in control group showed fine homodisperse, erythrocytes in treatment group performed better dispersion than model groups. Erythrocyte deformation index (DI) and blood flow value showed a statistic improvement in treatment group than control and model group (P<0.01). Value of DI in treatment group decreased after 18 weeks than values before therapy (P<0.01). Varying degrees of Aorta plaque formation was observed for individual difference in model and treatment groups, while no plaque was found in control group. Conclusions: Low energy laser improve microcirculation, rheological properties and blood lipid that might be related with erythrocytes aggregation and deformability. PMID:27347336

  11. Effect of helium-neon and infrared laser irradiation on wound healing in rabbits

    SciTech Connect

    Braverman, B.; McCarthy, R.J.; Ivankovich, A.D.; Forde, D.E.; Overfield, M.; Bapna, M.S.

    1989-01-01

    We examined the biostimulating effects of helium-neon laser radiation (HeNe; 632.8 nm), pulsed infrared laser radiation (IR; 904 nm), and the two combined on skin wound healing in New Zealand white rabbits. Seventy-two rabbits received either (1) no exposure, (2) 1.65 J/cm2 HeNe, (3) 8.25 J/cm2 pulsed IR, or (4) both HeNe and IR together to one of two dorsal full-thickness skin wounds, daily, for 21 days. Wound areas were measured photographically at periodic intervals. Tissue samples were analyzed for tensile strength, and histology was done to measure epidermal thickness and cross-sectional collagen area. Significant differences were found in the tensile strength of all laser-treated groups (both the irradiated and nonirradiated lesion) compared to group 1. No differences were found in the rate of wound healing or collagen area. Epidermal growth was greater in the HeNe-lased area compared to unexposed tissue, but the difference was not significant. Thus, laser irradiation at 632.8 nm and 904 nm alone or in combination increased tensile strength during wound healing and may have released tissue factors into the systemic circulation that increased tensile strength on the opposite side as well.

  12. Elemental analysis of Egyptian crude oils by INAA using rabbit irradiation system at ETRR-2 reactor.

    PubMed

    El-Khayatt, A M

    2010-12-01

    Instrumental neutron activation analysis (INAA) using rabbit irradiation system at ETRR-2 reactor was utilized to analyze some elements namely Na, Mg, Al, Cl, V, Mn, In, and Br in four different crude petroleum samples from different oil fields in the Suez-Gulf region of Egypt. The INAA was performed by four different standardization methods. Namely absolute, single comparator based on effective cross section concept, single comparator based on k(0,Au) factors, and that based on k(0,ic) factors defined versus any suitable internal comparator method. A FORTRAN computer program was written to calculate the extracted concentrations by these methods. A reasonable agreement between the obtained results was noticed. PMID:20692177

  13. Effects of low-energy He-Ne laser irradiation on posttraumatic degeneration of adult rabbit optic nerve

    SciTech Connect

    Schwartz, M.; Doron, A.; Erlich, M.; Lavie, V.; Benbasat, S.; Belkin, M.; Rochkind, S.

    1987-01-01

    Axons of the mammalian peripheral and central nervous systems degenerate after nerve injury. We have recently found that He-Ne laser irradiation may prevent some of the consequences of the injury in peripheral nerves of mammals. In the present study, the efficacy of the laser in treating injured neurons of the mammalian CNS was tested. Optic nerves of adult rabbits were exposed daily for 8-14 days to He-Ne laser irradiation (14 min, 15 mW) through the overlying muscles and skin. As a result of this treatment, the injured nerves maintained their histological integrity, which is invariably lost in injured mammalian CNS neurons.

  14. A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

    SciTech Connect

    Cai Jing; Mata, Jaime F.; Orton, Matthew D.; Hagspiel, Klaus D.; Mugler, John P.; Larner, James M.; Sheng Ke; Read, Paul W.

    2009-04-01

    Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

  15. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  16. Differential analysis of D-{beta}-Asp-containing proteins found in normal and infrared irradiated rabbit lens

    SciTech Connect

    Takata, Takumi; Shimo-Oka, Tadashi; Kojima, Masami; Miki, Kunio; Fujii, Noriko . E-mail: nfujii@HL.rri.kyoto-u.ac.jp

    2006-05-26

    Although proteins are generally composed of L-{alpha}-amino acids, D-{beta}-aspartic acid (Asp)-containing proteins have been reported in various elderly tissues. Our previous study detected several D-{beta}-Asp-containing proteins in a rabbit lens derived from epithelial cell line by Western blot analysis of a 2D-gel using a polyclonal antibody that is highly specific for D-{beta}-Asp-containing proteins. The identity of each spot was subsequently determined by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and the Ms-Fit online database searching algorithm. In this study, we discovered novel D-{beta}-Asp-containing proteins from rabbit lens. The results indicate that {beta}-crystallin A3, {beta}-crystallin A4, {beta}-crystallin B1, {beta}-crystallin B2, {beta}-crystallin B3, {gamma}-crystallin C, {gamma}-crystallin D, and {lambda}-crystallin in rabbit lens contain D-{beta}-Asp residues. Furthermore, the occurrence of D-{beta}-Asp residues increases with infrared ray (IR) irradiation. Additionally, some D-{beta}-Asp-containing proteins only appear after IR irradiation. One such protein is the {alpha}-enolase, which shows homology to {tau}-crystallin.

  17. Investigation of carbohydrate and protein metabolism in the digestive organs of the rabbit under the combined influence of vibration, acceleration and irradiation

    NASA Technical Reports Server (NTRS)

    Yuy, R. I.

    1975-01-01

    During spaceflight, the organism is subjected to the influence of various extremal factors such as acceleration, vibration, irradiation, etc. The study of the influence of these factors on metabolism, especially carbohydrate and protein metabolism, in young rabbits is of great significance in simulation experiments. Dynamic factors and irradiation, depending on dose and duration, lead to reduced RNA and protein metabolism.

  18. Effects of low-intensity laser irradiation on the apoptosis of rabbit vascular smooth muscle cells in culture

    NASA Astrophysics Data System (ADS)

    Li, S. D.; Chen, P.; Zhang, C. P.; Wen, J. X.; Liang, J.; Kang, H. X.; Gao, R. L.; Fu, X. B.

    2011-11-01

    Restenosis is a major complication after coronary intervention therapy. Excessive proliferation of vascular smooth muscle cells (VSMCs) and a decline in their apoptosis, which eventually leads to excessive neointimal thickening in coronary arteries, are the main causes of restenosis. Induction of the apoptosis of VSMCs and inhibition of excessive proliferation of VSMCs are therefore crucial for the prevention of restenosis, and low-intensity laser irradiation of coronary arteries may play a promising role in keeping this in balance. In this study, we used in vitro cultured rabbit VSMCs to investigate the effects of low-intensity laser irradiation at a wavelength of 532 nm on the apoptosis of VSMCs via morphological observation and molecular biology. The results showed that apoptotic bodies and obvious intranuclear apoptosis-positive particles formed within VSMCs 24 h after laser irradiation, suggesting that low-intensity laser irradiation at certain doses can inhibit the proliferation of VSMCs by promoting their apoptosis. This experiment provides evidences for further animal experiments and clinical trials on prevention and treatment of restenosis by intracoronary low-intensity laser irradiation at a wavelength of 532 nm.

  19. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  20. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  1. The effect of topical dexamethasone and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit

    SciTech Connect

    Miller, M.H.; Grierson, I.; Unger, W.G.; Hitchings, R.A. )

    1990-01-01

    We studied the effect of topical dexamethasone (1%) and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit. Intraocular pressure and gross facility of aqueous outflow following surgery were not influenced by either treatment, although blebs persisted longer in the irradiated eyes. Steroids reduced clinically observable inflammation as well as the number of inflammatory cells identifiable by microscopy. Fibroblast production temporarily slowed, and ultrastructural examination demonstrated lipid-filled vacuoles and dilated mitochondria in these eyes. Also, the scar was thinner at 24 days. Beta irradiation delayed wound healing and the scar was thinner in the early postoperative stages, but the light microscopic appearance of the scar was unaltered at 59 days. Inflammation was more pronounced initially, with abundant fibrin in the wound. Recovery of the conjunctival epithelium was delayed. The delay in fibroblast recruitment and wound contraction, the thinner scar tissue, and the increased survival of the bleb are all factors that suggest that beta irradiation may be a useful adjunct to glaucoma surgery.

  2. Pneumatically erected rigid habitat

    NASA Technical Reports Server (NTRS)

    Salles, Bradley

    1992-01-01

    The pneumatically erected rigid habitat concept consists of a structure based on an overexpanded metal bellows. The basic concept incorporates the advantages of both inflatable and rigid structures. The design and erection detail are presented with viewgraphs.

  3. High resolution scanning electron microscopy of rabbit corneal endothelium to show effects of UV-visible irradiation in the presence of chlorpromazine

    SciTech Connect

    Lea, P.J.; Hollenberg, M.J.; Menon, I.A.; Temkin, R.J.; Persad, S.D.; Basu, P.K. )

    1989-01-01

    The ultrastructure of rabbit cornea endothelial cells was examined by scanning electron microscopy (SEM) in freeze-cleaved corneas using a Hitachi S-570 scanning electron microscope in the high resolution mode (HRSEM). In order to study phototoxic effects in vitro, rabbit corneas (experimental) were cultured as organ culture in the presence of 5 micrograms/ml chlorpromazine (CPZ) and irradiated. For comparison, control 1 corneas were not irradiated but incubated in the dark without CPZ in the medium; control 2 corneas were also kept in the dark but in the presence of CPZ; control 3 corneas were irradiated with no CPZ in the medium. Cellular damage was not seen in the three types of control corneas, but in the experimental corneas the endothelial cells showed extensive disruption of the cell membrane and some deterioration of the intracellular components. Our study confirmed that HRSEM is a satisfactory new technique for visualizing damage of the intracellular organelles of corneal endothelium.

  4. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    SciTech Connect

    Kawase, Takatsugu; Kunieda, Etsuo Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  5. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  6. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  7. Improvement of thermal effects to rabbit atherosclerotic aortas by macro pulse irradiation of a quantum cascade laser in the 5.7 μm wavelength range

    NASA Astrophysics Data System (ADS)

    Hashimura, Keisuke; Ishii, Katsunori; Awazu, Kunio

    2015-03-01

    Atherosclerotic plaques mainly consist of cholesteryl esters. Cholesteryl esters have an absorption peak at the wavelength of 5.75 μm originated from C=O stretching vibration mode of ester bond. Our group achieved making cutting difference between atherosclerotic lesions and normal vessels using a quantum cascade laser (QCL) in the 5.7 μm wavelength range. QCLs are relatively new types of semiconductor lasers that can emit mid-infrared range. They are sufficiently compact and have recently achieved their high-power emission. However, large thermal damage was observed because the QCL worked as a quasi-continuous wave laser due to its short pulse interval. To realize less invasive ablation by the QCL, reducing thermal effects to normal vessels is needed. In this study, we tried improving the thermal effects by changing the pulse structure. First, irradiation effects to rabbit atherosclerotic aortas by macro pulse irradiation (irradiation of pulses at intervals) and conventional continuous pulse irradiation were compared. The macro pulse width and the macro pulse interval were set to 0.54 and 12 ms, respectively, because the thermal relaxation time of rabbit normal and atherosclerotic aortas in the oscillation wavelength was 0.54-12 ms. As a result, ablation depth became longer and coagulation width became shorter by the macro pulse irradiation. In addition, cutting difference between rabbit normal and atherosclerotic aortas was observed by the macro pulse irradiation. Therefore, the macro pulse irradiation achieved the improvement of thermal effects by the QCL in the 5.7 μm wavelength range. The QCL has the potential of realizing less-invasive laser angioplasty.

  8. Pneumatic sample-transfer system for use with the Lawrence Livermore National Laboratory rotating target neutron source (RTNS-I)

    SciTech Connect

    Williams, R.E.

    1981-07-01

    A pneumatic sample-transfer system is needed to be able to rapidly retrieve samples irradiated with 14-MeV neutrons at the Rotating Target Neutron Source (RTNS-I). The rabbit system, already in place for many years, has been refurbished with modern system components controlled by an LSI-11 minicomputer. Samples can now be counted three seconds after an irradiation. There are many uses for this expanded 14-MeV neutron activation capability. Several fission products difficult to isolate from mixed fission fragments can be produced instead through (n,p) or (n,..cap alpha..) reactions with stable isotopes. Mass-separated samples of Nd, Mo, and Se, for example, can be irradiated to produce Pr, Nb, and As radionuclides sufficient for decay scheme studies. The system may also be used for multielement fast-neutron activation analysis because the neutron flux is greater than 2 x 10/sup 11/ n/cm/sup 2/-sec. Single element analyses of Si and O are also possible. Finally, measurements of fast-neutron cross sections producing short-lived activation products can be performed with this system. A description of the rabbit system and instructions for its use are presented in this report.

  9. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  10. Ultraviolet-irradiated vaccinia virus recombinants, exposing HIV-envelope on their outer membrane, induce antibodies against this antigen in rabbits.

    PubMed

    Loewinger, M; Katz, E

    2002-01-01

    The construction and isolation of recombinants of vaccinia virus (IHD-J strain), bearing on their outer membrane a chimeric protein consisting of the cytoplasmic and transmembrane domains of vaccinia B5R protein and the external domain of HIV envelope, has been previously described by us. The present study aimed to investigate the potential use of such recombinants as a vaccine, following inactivation of their infectivity by ultraviolet (UV) irradiation. The minimal dose of UV irradiation, required for the complete inactivation of the infectivity of these recombinants, was determined. Injections of rabbits with the irradiated noninfectious recombinant viruses successfully induced specific antibodies against the HIV envelope antigen, in addition to those against the poxvirus. PMID:12479396

  11. The influence of intravenous laser irradiation of blood on some metabolic and functional parameters in intact rabbits and experimental cerebral ischaemia

    NASA Astrophysics Data System (ADS)

    Nechipurenko, N.; Vasilevskaya, L.; Musienko, J.; Maslova, G.

    2007-07-01

    It has been studied the intravenous laser irradiation of blood (ILIB) influence with helium-neon laser (HNL) of 630 nm wavelength on some of lipid peroxidation (LPO) and antioxidant system (AOS) findings, aside-base status (ABS) and blood oxygen transport (BOT), state of dermal microhaemodynamics (MGD) in the intact rabbits and after modeling of local ischemia of brain (LIB). Depending on conditions of organism functioning (norm or brain ischaemia) ILIB has resulted in stimulating or normalizing effects on the whole metabolic and microhaemocirculation processes which had been studied during our investigation. It is discussed the mechanisms of pathogenetic directivity of ILIB influence in cerebral ischaemia

  12. The complication of pneumatic retinopexy.

    PubMed Central

    Hilton, G F; Tornambe, P E; Brinton, D A; Flood, T P; Green, S; Grizzard, W S; Hammer, M E; Leff, S R; Mascuilli, L; Morgan, C M

    1990-01-01

    There have been 26 published series with a total of 1274 detachments operated with pneumatic retinopexy. Eighty percent were reattached with a single procedure and 98% with reoperations. New breaks occurred in 13% and PVR in 4%. The complications published in 101 papers on pneumatic retinopexy in the last 5 years are analyzed as to frequency, prevention, management, and results. PMID:2095021

  13. Pneumatic Pellet-Transporting System

    NASA Technical Reports Server (NTRS)

    Wood, George; Pugsley, Robert A.

    1992-01-01

    Pneumatic system transports food pellets to confined animals. Flow of air into venturi assembly entrains round pellets, drawing them from reservoir into venturi for transport by airflow. Pneumatic pellet-transporting system includes venturi assembly, which creates flow of air that draws pellets into system.

  14. Pneumatization of the sphenoid sinus.

    PubMed

    Terra, E R; Guedes, F R; Manzi, F R; Bóscolo, F N

    2006-01-01

    This paper describes a case of pneumatization of the sphenoid sinus in the pterygoid process and greater wing of the sphenoid bone, observed on a panoramic radiograph. Conventional radiographs and computerized tomography in axial and coronal sections confirmed the presence of the pneumatization of these structures. PMID:16421265

  15. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays

    SciTech Connect

    el-Mofty, M.M.; Sakr, S.A.; Younis, M.W. )

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin.

  16. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays.

    PubMed

    el-Mofty, M M; Sakr, S A; Younis, M W

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin. PMID:2794550

  17. Mucosal injury and. gamma. -irradiation produce persistent gastric ulcers in the rabbit. Evaluation of antiulcer drug binding to experimental ulcer sites

    SciTech Connect

    Yokel, R.A.; Dickey, K.M. )

    1991-05-01

    A method producing persistent gastric ulcers in the rhesus monkey by combined mucosal injury and {gamma}-irradiation was modified and evaluated in the rabbit. {gamma}-Irradiation (800-1000 cGy) immediately after removal of 2-mm-diameter sections of antral mucosa resulted in ulcer craters 5-7 days later. Ulcer sites were characterized by loss of the mucosa, muscularis mucosa, and much of the submucosa. The exposed submucosa was coated with fibrin and necrotic debris infiltrated with heterophils, the rabbit equivalent of neutrophils. These ulcers strongly resemble human chronic gastric ulcers. Binding of Carafate (sucralfate; Marion Laboratories, Inc., Kansas City, MO) and Maalox (magnesia-alumina oral suspension; Wm. H. Rorer, Inc., Ft. Washington, PA) to ulcer and nearby nonulcer sites in the antrum was assessed 1 hour after drug dosing. Drug binding was determined by aluminum quantitation of stomach wall punch biopsies at necropsy. Both drugs significantly increased aluminum bound to the stomach wall compared with vehicle treatment. Significantly more antiulcer drug was bound to ulcer sites than to nearby nonulcer sites only after sucralfate administration. This model of persistent gastric ulcer should be useful to further study gastric ulcer pathogenesis and treatment.

  18. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A mechanized technique to seal abandoned mines has been used successfully to close 13 openings at Duquesne Light Co.'s mined-out Warwick No. 2 mine, near Greensboro, Pa. The mechanized system, which uses a pneumatic stower and crushed limestone, closed the entries more economically and in less time than it would have taken to install traditional concrete block stopping and clay plug seals, according to John C. Draper. Draper, a mining engineer with Duquesne Light's coal department, was in charge of installing the Warwick seals in a Bureau of Mines-sponsored field test on the pneumatic sealing technique. The lowest estimated cost for installing conventional stopping and plug closures for the 13 Warwick openings was $225,000, says Draper, while the openings were closed using the mechanized system for $245,000. Draper says the newer stopping cost more in the instance because work was stopped often to gather information for the experiment. The experimental closures were installed in 38 days. The job would have taken at least 149 days if traditional closures were being installed, Draper say. To install a traditional concrete block/clay plug closure, the mine opening must be cleaned thoroughly and the roof must be supported for some 3 ft from the outside. Then a solid wall or stopping must be built 25 ft from the surface and the entry must be packed with clay to the surface. Much of this job requires workers to remain underground. In pneumatic stowing, 1 1/2-in. crushed limestone with fines is conveyed through a pipeline and into the mine opening under low air pressure. Watertight seals can be installed by blowing about 10 ft of rock into the opening against the top to act as roof support. Safety posts are installed and about 10 or 15 ft of mine entry is cleaned. About 2 in. of raw cement or bentonite is placed on the floor and limestone mixed with dry cement or bentonite is blown into the opening.

  19. PNEUMATIC PUMPING TEST FOR SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. etermination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. ressure propaga...

  20. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  1. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  2. The Anti-calcification Effect of Dithiobispropionimidate, Carbodiimide and Ultraviolet Irradiation Cross-linking Compared to Glutaraldehyde in Rabbit Implantation Models

    PubMed Central

    Park, Samina; Kim, Soo Hwan; Lim, Hong-Gook; Lim, Cheong

    2013-01-01

    Background Glutaraldehyde (GA) is a widely used cross-linking agent for improving mechanical properties and resistance to enzymatic degradation of collagenous tissue, but it has several drawbacks such as calcification and cytotoxicity. The aim of this study was to find the alternative effective cross-linking methods to GA. Materials and Methods Bovine pericardium was processed with GA with ethanol+octanol and glycine detoxification, and polyethylene glycol (PG) space filler, dimethyl 3,3'-dithiobispropionimidate (DTBP), 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) treatment, and the physical fixation of ultraviolet irradiation were done. The biologic material properties of variously treated pericardial tissues were assessed by biochemical, mechanical and histological tests. Treated pericardial tissues were also implanted subcutaneously or intramuscularly into the rabbit for 10 weeks to assess the xenoreactive antibody response of immunoglobulin G and M, their anti-calcification effect. Results The biochemical and mechanical properties of EDC fixed pericardial tissues were comparable to the GA fixed tissue. The cytotoxicity was lowest in space filler treated GA fixed group. In rabbit subcutaneous or intramuscular implantation models, decellularization, space filler, EDC treatment group showed significantly lower calcium content than GA only and DTBP treatment group (p<0.05, analysis of variance). The titer of anti Galα1-3Galβ1-4GlcNAc-R antibodies did not change in the postimplantation serial enzyme-linked immunosorbent assay. Hematoxylin and eosin and von Kossa staining showed that decellularization, space filler, EDC, and ultraviolet treatment had less inflammatory cell infiltration and calcium deposits. Conclusion The decellularization process, PG filler, and EDC treatments are good alternative cross-linking methods compared to GA only fixation and primary amine of DTBP treatment for cardiovascular xenograft preservation in terms of the collagen cross

  3. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  4. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  5. Pneumatic Spoiler Controls Airfoil Lift

    NASA Technical Reports Server (NTRS)

    Hunter, D.; Krauss, T.

    1991-01-01

    Air ejection from leading edge of airfoil used for controlled decrease of lift. Pneumatic-spoiler principle developed for equalizing lift on helicopter rotor blades. Also used to enhance aerodynamic control of short-fuselage or rudderless aircraft such as "flying-wing" airplanes. Leading-edge injection increases maneuverability of such high-performance fixed-wing aircraft as fighters.

  6. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    NASA Astrophysics Data System (ADS)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  7. Sliding pressure control valve for pneumatic hammer drill

    SciTech Connect

    Polsky, Yarom

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  8. Automatic irradiation control by an optical feedback technique for selective retina treatment (SRT) in a rabbit model

    NASA Astrophysics Data System (ADS)

    Seifert, Eric; Roh, Young-Jung; Fritz, Andreas; Park, Young Gun; Kang, Seungbum; Theisen-Kunde, Dirk; Brinkmann, Ralf

    2013-06-01

    Selective Retina Therapy (SRT) targets the Retinal Pigment Epithelium (RPE) without effecting neighboring layers as the photoreceptors or the choroid. SRT related RPE defects are ophthalmoscopically invisible. Owing to this invisibility and the variation of the threshold radiant exposure for RPE damage the treating physician does not know whether the treatment was successful or not. Thus measurement techniques enabling a correct dosing are a demanded element in SRT devices. The acquired signal can be used for monitoring or automatic irradiation control. Existing monitoring techniques are based on the detection of micro-bubbles. These bubbles are the origin of RPE cell damage for pulse durations in the ns and μs time regime 5μs. The detection can be performed by optical or acoustical approaches. Monitoring based on an acoustical approach has already been used to study the beneficial effects of SRT on diabetic macula edema and central serous retinopathy. We have developed a first real time feedback technique able to detect micro-bubble induced characteristics in the backscattered laser light fast enough to cease the laser irradiation within a burst. Therefore the laser energy within a burst of at most 30 pulses is increased linearly with every pulse. The laser irradiation is ceased as soon as micro-bubbles are detected. With this automatic approach it was possible to observe invisible lesions, an intact photoreceptor layer and a reconstruction of the RPE within one week.

  9. Pneumatic actuator with hydraulic control

    NASA Astrophysics Data System (ADS)

    Everett, Hobart R., Jr.

    1992-11-01

    The present invention provides a pneumatically powered actuator having hydraulic control for both locking and controlling the velocity of an output rod without any sponginess. The invention includes a double-acting pneumatic actuator having a bore, a piston slidably engaged within the bore, and a control rod connected to the piston. The double-acting pneumatic actuator is mounted to a frame. A first double-acting hydraulic actuator having a bore, a piston slidably engaged within the bore, and a follower rod mounted to the piston is mounted to the frame such that the follower rod is fixedly connected to the control rod. The maximum translation of the piston within the bore of the first double-acting hydraulic actuator provides a volumetric displacement V1. The present invention also includes a second double-acting hydraulic actuator having a bore, a piston slidably engaged within the bore, and an output rod mounted to the piston. The maximum translation of the piston within the bore of the second double-acting hydraulic actuator provides a volumetric displacement V2, where V2=V1. A pair of fluid ports in each of the first and second double-acting hydraulic cylinders are operably connected by fluid conduits, one of which includes a valve circuit which may be used to control the velocity of the output rod or to lock the output rod in a static position by regulating the flow of hydraulic fluid between the double-acting cylinders.

  10. Electric versus hydraulics versus pneumatics

    SciTech Connect

    Not Available

    1985-01-01

    This book presents a collection of papers from a conference which considered the advantages and disadvantages of electric, hydraulic and pneumatic drives and actuators. The volume follows on the success of the 1983 conference on electric and hydraulic drives. Topics considered include fork lift trucks - an ideal application for regenerative transmissions; a hybrid-electric power system with hydrostatic transmission; electrics and hydraulics on roadheader machinery; hydraulic, electrical, pneumatic control - which way to go. an electrically-powered servo to drive the two axes of a missile launching platform - pros and cons when compared with the traditional hydraulic solution; the encapsulation of a novel intrinsically safe displacement transducer; mobile cryogenic pumping systems; automation of a wood-turning machine, hydraulic or electric. The choice of a servo motor for a specific application; developments in the design and control of pneumatic linear actuators; compressed air purification for instrumentation in the high technology industries; trends in prime mover choice for powered hand tools; and choosing the drive system for the right application.

  11. Pneumatic well casing pressure regulating system

    SciTech Connect

    Flohr, M.C.

    1987-10-20

    A pneumatic well casing pressure regulating system is described comprising: a hydraulically actuated choke for relieving well casing pressure; a continually running source of pneumatic pressure pulses; first means for applying pulses of hydraulic fluid corresponding to the pneumatic pressure pulses to the choke for opening the choke one step for each pulse of hydraulic fluid when actual casing pressure is higher than a desired casing pressure; and second means for applying pulses of hydraulic fluid corresponding to the pneumatic pressure pulses to the choke for closing the choke one step for each pulse of hydraulic fluid when actual casing pressure is less than a desired casing pressure.

  12. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  13. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  14. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  15. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  16. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  17. RANGE INCREASER FOR PNEUMATIC GAUGES

    DOEpatents

    Fowler, A.H.; Seaborn, G.B. Jr.

    1960-09-27

    An improved pneumatic gage is offered in which the linear range has been increased without excessive air consumption. This has been accomplished by providing an expansible antechamber connected to the nozzle of the gage so that the position of the nozzle with respect to the workpiece is varied automatically by variation in pressure within the antechamber. This arrangement ensures that the nozzle-to-workpiece clearance is maintained within certain limits, thus obtaining a linear relation of air flow to nozzle-to-workpiece clearance over a wider range.

  18. Pneumatically tunable optofluidic dye laser

    NASA Astrophysics Data System (ADS)

    Song, Wuzhou; Psaltis, Demetri

    2010-02-01

    We presented a tunable optofluidic dye laser with integrated elastomeric air-gap etalon controlled by air pressure. The chip was fabricated with polydimethylsiloxane (PDMS) via replica molding. It comprises a liquid waveguide and microscale air-gap mirrors providing the feedback. The lasing wavelength is chosen by the interference between two parallel PDMS-air interfaces inside the internal tunable air-gap etalon, of which pneumatic tuning can be realized by inflating the air-gap etalon with compressed air. This dye laser exhibits a pumping threshold of 1.6 μJ/pulse, a lasing linewidth of 3 nm, and a tuning range of 14 nm.

  19. Experimental Plan for EDF Energy Creep Rabbit Graphite Irradiations- Rev. 2 (replaces Rev. 0 ORNL/TM/2013/49).

    SciTech Connect

    Burchell, Timothy D

    2014-07-01

    The experimental results obtained here will assist in the development and validation of future models of irradiation induced creep of graphite by providing the following data: Inert creep stain data from low to lifetime AGR fluence Inert creep-property data (especially CTE) from low to lifetime AGR fluence Effect of oxidation on creep modulus (by indirect comparison with experiment 1 and direct comparison with experiment 3 NB. Experiment 1 and 3 are not covered here) Data to develop a mechanistic understanding, including oAppropriate creep modulus (including pinning and high dose effects on structure) oInvestigation of CTE-creep strain behavior under inert conditions oInformation on the effect of applied stress/creep strain on crystallite orientation (requires XRD) oEffect of creep strain on micro-porosity (requires tomography & microscopy) This document describes the experimental work planned to meet the requirements of project technical specification [1] and EDF Energy requests for additional Pre-IE work. The PIE work is described in detail in this revision (Section 8 and 9).

  20. Pneumatic conveying of pulverized solvent refined coal

    DOEpatents

    Lennon, Dennis R.

    1984-11-06

    A method for pneumatically conveying solvent refined coal to a burner under conditions of dilute phase pneumatic flow so as to prevent saltation of the solvent refined coal in the transport line by maintaining the transport fluid velocity above approximately 95 ft/sec.

  1. Note: A fast pneumatic sample-shuttle with attenuated shocks

    SciTech Connect

    Biancalana, Valerio; Dancheva, Yordanka; Stiaccini, Leonardo

    2014-03-15

    We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

  2. Caudal Pneumaticity and Pneumatic Hiatuses in the Sauropod Dinosaurs Giraffatitan and Apatosaurus

    PubMed Central

    Wedel, Mathew J.; Taylor, Michael P.

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula—those that leave few or no skeletal traces—in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy. PMID:24205162

  3. Pneumatic transfer of solids into wells

    SciTech Connect

    Sweatman, R. E.; Freeman, E. R.; Gottschling, J.; Simon, J.

    1985-04-23

    A method for pneumatically transferring particulate solid materials into an earth formation penetrated by a well bore is shown. A gas is flowed into the well bore to establish the desired injection rate and pressure. A particulate solid material is then added to the established gas flow passing into the well bore by flowing a gas containing an entrained particulate solid material into the established gas flow to thereby transfer the solid particulate material pneumatically into the well bore.

  4. Pneumatic fracturing of low permeability media

    SciTech Connect

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  5. Promising pneumatic punchers for borehole drilling

    SciTech Connect

    A.A. Lipin

    2005-03-15

    The state of borehole drilling by downhole pneumatic punchers and their potential use in open and underground mining as well as in exploration for reliable sampling are analyzed. Performance specification is presented for the new-generation pneumatic punchers equipped with a pin tool, effectively operating at a compressed-air pressure of 0.5-0.7 MPa, and with an additional extended exhaust from the power stroke chamber during working cycle.

  6. Carbon Nanotube Amperometric Chips with Pneumatic Micropumps

    NASA Astrophysics Data System (ADS)

    Tsujita, Yuichi; Maehashi, Kenzo; Matsumoto, Kazuhiko; Chikae, Miyuki; Torai, Soichiro; Takamura, Yuzuru; Tamiya, Eiichi

    2008-04-01

    We fabricated carbon nanotube (CNT) amperometric chips with pneumatic micropumps by the combination of amperometric biosensors based on CNT-arrayed electrodes and microchannels with pneumatic micropumps made of poly(dimethylsiloxane). On the chip, phosphate buffer solution and potassium ferricyanide, K3[Fe(CN)6], were introduced into the CNT electrodes using each pneumatic micropump and electrochemically measured by differential pulse voltammetry. The results indicate that our chip can automatically exchange reagents on the CNT electrodes and clearly detect molecules. Moreover, by modifying the CNT electrodes with enzyme glucose oxidase, glucose molecules could be detected using our chips by cyclic voltammetry and chronoamperometry. We conclude that microfluidic chips with CNT-arrayed electrodes are a promising candidate for the development of hand-held electrochemical biosensors.

  7. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  8. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  9. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  10. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  11. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  12. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  13. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  14. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  15. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  16. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  17. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  18. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  19. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  20. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  1. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  2. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  3. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  4. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  5. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  6. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  7. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  8. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  9. Pneumatics. Student's Manual [and] Instructor's Guide.

    ERIC Educational Resources Information Center

    Notgrass, Troy

    The student's manual in this two-part instructional kit is designed to help the following types of students learn introductory technical material related to pneumatics: (1) groups of trade and industrial students with a variety of vocational objectives and (2) homogeneous groups in which the learning levels of individual students vary…

  10. Management of achalasia: surgery or pneumatic dilation.

    PubMed

    Richter, Joel E; Boeckxstaens, Guy E

    2011-06-01

    Achalasia is an esophageal motility disorder of unknown cause, characterised by aperistalsis of the esophageal body and impaired lower esophageal sphincter relaxation. Patients present at all ages, primarily with dysphagia for solids/liquids and bland regurgitation. The diagnosis is suggested by barium esophagram or endoscopy and confirmed by esophageal manometry. Achalasia cannot be cured. Instead, our goal is to relieve symptoms, improve esophageal emptying and prevent the development of megaesophagus. The most successful therapies are pneumatic dilation and surgical myotomy. The advantages of pneumatic dilation include an outpatient procedure, minimal pain, return to work the next day, mild if any GERD, and can be performed in any age group and even during pregnancy. Pneumatic dilation does not hinder future myotomy, and all cost analyses find it less expensive than Heller myotomy. Laparoscopic myotomy with a partial fundoplication has the advantage of being a single procedure, dysphagia relief is longer at the cost of more troubling heartburn, and a myotomy may be more effective treatment in adolescents and younger adults, especially men. Over a two year horizon, the clinical success of pneumatic dilation and laparoscopic myotomy are comparable in a recent large European randomised trial. The prognosis for achalasia patients to return to near-normal swallowing and good quality of life are excellent, but few are "cured" with a single treatment and intermittent "touch up" procedures may be required. PMID:21303915

  11. Analysis of fine coal pneumatic systems

    SciTech Connect

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying size consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.

  12. Field demonstration of two pneumatic backfilling technologies

    SciTech Connect

    Dyni, R.C.; Burnett, M.; Philbin, D.

    1995-12-31

    This US Bureau of Mines (USBM) report summarizes a field demonstration of pneumatic backfilling technologies conducted at the abandoned Hillside Coal and Iron Slope in Vandling, PA. Researchers demonstrated two pneumatic backfilling technologies recently developed under the USBM`s Abandoned Mine Reclamation Research Program, the Pneumatic Pipefeeder and the High-Efficiency Ejector. Both systems had previously been evaluated at the USBM`s subsidence abatement investigation laboratory near Fairchance, PA. The objective of the demonstration was to fill 100% of the abandoned tunnel with backfill stone to prevent further subsidence. The pneumatic Pipefeeder was used for 21 days, at a rate of 63 to 124 t/d (69 to 136 st/d), to fill 88% of the tunnel. The High-Efficiency Ejector was used for 2 days, at a rate of 125 to 132 T/d (138 to 146 st/d) to fill the remaining 12% of the tunnel. The backfill placed by both systems was tightly compacted. The major problem encountered was wear on the polyethylene pipeline from the abrasion of the high-velocity backfill. The use of heavier steel pipe minimized the problem. A cost analysis for the entire project is given.

  13. PNEUMATIC FRACTIONATOR FOR CLEANING GINNED LINT

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. Spawned from discussions at a Cotton Incorporated Lint Cleaning Summit and building on 1970s research at the Southwestern Cotton Ginning Research Laboratory, an e...

  14. Evaluating a device for pneumatic lint cleaning

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Research exploring innovative techniques to clean ginned lint while reducing short fiber and neps has led to evaluations of a pneumatic fractionator. This device is typically used to determine foreign matter content of seed cotton at the USDA cotton ginning research laboratories. No modifications we...

  15. Pneumatic boot for helicopter rotor deicing

    NASA Technical Reports Server (NTRS)

    Blaha, B. J.; Evanich, P. L.

    1981-01-01

    Pneumatic deicer boots for helicopter rotor blades were tested. The tests were conducted in the 6 by 9 ft icing research tunnel on a stationary section of a UH-IH helicopter main rotor blade. The boots were effective in removing ice and in reducing aerodynamic drag due to ice.

  16. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    PubMed

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L; Benson, Roger B J; Choiniere, Jonah; Davidson, Amy; Norell, Mark A

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  17. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  18. Pneumatic hammer in aerostatic thrust bearings with single orifice compensation

    NASA Astrophysics Data System (ADS)

    Kong, Zhongke; Tao, Jizhong

    2013-01-01

    In dealing with the phenomenon of the pneumatic hammer in aerostatic thrust bearings, the vibrant model of the one-single freedom system has been established to study the pneumatic hammer from the point of sympathetic vibration. It is found that the bearings show a tendency to result in the pneumatic hammer with the increase of air supply pressure, and the occurrence probability of the pneumatic hammer will be reduced when the gas film thickness is maintained within a certain range. Meanwhile, the existence of the pneumatic hammer, which is caused by sympathetic vibration, is experimentally verified, and it is found that gas bearings undergo certain disturbance, which causes the system to produce micro breadth vibration. Accordingly, the micro breadth vibration causes the gas film and thrust face to form flow/structure coupled to excite the pneumatic hammer. Therefore, it provides another path to study the pneumatic hammer and is of academic value.

  19. Morphologic findings in the rabbit retina following irradiation with the free-running neodymium-YAG laser. Disruption of Bruch's membrane and its effect on the scarring process in the retina and choroid

    SciTech Connect

    van der Zypen, E.; Fankhauser, F.; Raess, K.; England, C.

    1986-07-01

    The scarring process induced within the retina and choroid of pigmented rabbits' eyes following irradiation with the neodymium-YAG laser (working in the free-running mode) was examined at the ultrastructural level. Scarring of the sensory retina proceeded rapidly and was well advanced two weeks after irradiation, whereas in the choroid, signs of repair were apparent only after six weeks. This difference in the rate of repair between the two tissues has a bearing on the scarring pattern in the retinochoroid as a whole. The severity of damage to the elastic component of Bruch's membrane also has important consequences in relation to the repair processes in the retina and choroid. Microfractures within this layer, while enabling migrating cells of various kinds to penetrate into the inner collagenous zone, did not prevent complete regeneration of the retinal pigment epithelium (RPE). In instances of greater rupture, however, RPE regeneration was found to stop at the border of the break, and the discontinuity produced within Bruch's membrane and the RPE allowed the glial scar to expand into the choroid. In this region, new formation of vessels was not found.

  20. Milestone M3FT-15OR0203112. Build redesigned HFIR rabbit capsules and make ready for insertion for irradiation in HFIR

    SciTech Connect

    Howard, Richard H; McDuffee, Joel Lee; Okuniewski, Maria A.

    2015-09-01

    This report details the fabrication and delivery of two Fuel Cycle Research and Development irradiation capsules (FCRP20 and FCRP03), with associated quality assurance documentation, to the High Flux Isotope Reactor. The capsules and documentation were delivered by September 30, 2015, thus meeting the deadline for milestone M3FT-15OR0203112. These irradiation experiments irradiate metal parallelepiped specimens that may consist of various compositions including uranium metal, steel, etc. This document contains a copy of the completed capsule fabrication request sheets, which detail all constituent components, pertinent drawings, etc., along with a detailed summary of the capsule assembly process performed by the Thermal Hydraulics and Irradiation Engineering Group (THIEG) in the Reactor and Nuclear Systems Division. A complete fabrication package record is maintained by THIEG and is available upon request.

  1. Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Feldman, Jason; Svehla, Danielle

    2003-01-01

    Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric

  2. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  3. Viral infections of rabbits.

    PubMed

    Kerr, Peter J; Donnelly, Thomas M

    2013-05-01

    Viral diseases of rabbits have been used historically to study oncogenesis (e.g. rabbit fibroma virus, cottontail rabbit papillomavirus) and biologically to control feral rabbit populations (e.g. myxoma virus). However, clinicians seeing pet rabbits in North America infrequently encounter viral diseases although myxomatosis may be seen occasionally. The situation is different in Europe and Australia, where myxomatosis and rabbit hemorrhagic disease are endemic. Advances in epidemiology and virology have led to detection of other lapine viruses that are now recognized as agents of emerging infectious diseases. Rabbit caliciviruses, related to rabbit hemorrhagic disease, are generally avirulent, but lethal variants are being identified in Europe and North America. Enteric viruses including lapine rotavirus, rabbit enteric coronavirus and rabbit astrovirus are being acknowledged as contributors to the multifactorial enteritis complex of juvenile rabbits. Three avirulent leporid herpesviruses are found in domestic rabbits. A fourth highly pathogenic virus designated leporid herpesvirus 4 has been described in Canada and Alaska. This review considers viruses affecting rabbits by their clinical significance. Viruses of major and minor clinical significance are described, and viruses of laboratory significance are mentioned. PMID:23642871

  4. MANUAL DEGATING OPERATIONS PERFORMED BY SLEDGEHAMMERS AND PNEUMATIC WEDGE SEPARATORS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MANUAL DEGATING OPERATIONS PERFORMED BY SLEDGE-HAMMERS AND PNEUMATIC WEDGE SEPARATORS. - Southern Ductile Casting Company, Shaking, Degating & Sand Systems, 2217 Carolina Avenue, Bessemer, Jefferson County, AL

  5. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug was administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls, All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p less than 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p less than 0.05) and pericardial effusion (p less than 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p less than 0.05) or IB (p less than 0.01) and in the untreated, unirradiated rabbits (p less than 0.01). Early administration of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusion, and improved survival in this experimental model of radiation-induced heart disease.

  6. Pneumatic transport of coal by steam

    SciTech Connect

    Ekmann, J.M.; Wildman, D.J.; Mathur, M.P.; Klinzing, G.E.

    1985-01-01

    Steam has been suggested as the transport gas in power plant facilities where the availability high pressure steam already exists. The transport of coal pneumatically by the use of steam to a loading ratio of 10 has been studied experimentally in a 0.0107 meter diameter pipe. Analysis of the energy losses in transport of the steam-coal mixture has been carried out using a model based on thermodynamic and fluid mechanics principles. Good agreement between the data and model has been obtained.

  7. Pneumatic transport of coal by steam

    SciTech Connect

    Wildman, D.J.; Mathur, M.P.; Ekmann, J.M.; Klinzing, G.E.

    1984-01-01

    Steam has been suggested as the transport gas in power plant facilities where the availability of high pressure steam already exists. The transport of coal pneumatically by the use of steam to a loading ratio of 10 has been studied experimentally in a 3/8'' pipe. Analysis of the energy losses in transport of the steam-coal mixture has been carried out using a model based on thermodynamic and fluid mechanics principles. Good agreement between the data and model has been obtained. 4 references, 2 figures.

  8. Pneumatic Artificial Muscle Actuation and Modeling

    NASA Astrophysics Data System (ADS)

    Leephakpreeda, Thananchai; Wickramatunge, Kanchana C.

    2009-10-01

    A Pneumatic Artificial Muscle (PAM) yields a natural muscle-like actuator with a high force to weight ratio, a soft and flexible structure, and adaptable compliance for a humanoid robot, rehabilitation and prosthetic appliances to the disabled, etc. To obtain optimum design and usage, the mechanical behavior of the PAM need to be understood. In this study, observations of experimental results reveal an empirical model for relations of physical variables, contraction and air pressure within the PAM, as compared to mechanical characteristics, such as stiffness or/and pulling forces of the PAM available now in market.

  9. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  10. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  11. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  12. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  13. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  14. Evaluating a pneumatic fractionator for cleaning ginned lint

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. An experiment was conducted to evaluate the pneumatic fractionator as a lint cleaning device. No modifications were made to the standard device, except that air p...

  15. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  16. Anatomical Factors Influencing Pneumatization of the Petrous Apex

    PubMed Central

    Kim, Min-Ju; Lee, Seunghun; Choi, Hana

    2015-01-01

    Objectives Aim of the present study was to define the relationship between petrous apex pneumatization and the nearby major anatomical landmarks using temporal bone computed tomography (CT) images. Methods This retrospective, Institutional Review Board-approved study analyzed CT images of 84 patients that showed normal findings bilaterally. Pneumatization of the petrous apex was classified using two methods. Eight parameters were as follows: angle between the posterior cranial fossa and internal auditory canal, Morimitsu classification of anterior epitympanic space, distance between the carotid canal and jugular bulb, distance between the cochlear modiolus and carotid canal, distance between the tympanic segment and jugular bulb, high jugular bulb, distance between the vertical segment and jugular bulb, and distance between the lateral semicircular canals and middle cranial fossa. Results There was a significant difference in Morimitsu classification of the anterior epitympanic space between the two classification methods. Poorly pneumatic upper petrous apices were distributed uniformly in three types of Morimitsu classification, but more pneumatic upper petrous apices were found more often in anterior type. Lower petrous apex was well pneumatized regardless of the types of anterior epitympanic space, but the largest amount of pneumatization was found more frequently in the anterior type of anterior epitympanic space. Conclusion This study showed that there was no reliable anatomic marker to estimate petrous apex pneumatization and suggests that the pneumatization of the petrous apex may be an independent process from other part of the temporal bone, and may not be influenced by the nearby major anatomical structures in the temporal bone. In this study, the anterior type of anterior epitympanic space was found to be closely related to more well-pneumatized petrous apices, which implies that the anterior saccule of the saccus medius may be the main factor

  17. Scaling of pneumatic digital logic circuits.

    PubMed

    Duncan, Philip N; Ahrar, Siavash; Hui, Elliot E

    2015-03-01

    The scaling of integrated circuits to smaller dimensions is critical for achieving increased system complexity and speed. Digital logic circuits composed of pneumatic microfluidic components have to this point been limited to a circuit density of 2-4 gates cm(-2), constraining the complexity of the digital systems that can be achieved. We explored the use of precision machining techniques to reduce the size of pneumatic valves and resistors, and to achieve more accurate and efficient placement of ports and vias. In this way, we attained an order of magnitude increase in circuit density, reaching as high as 36 gates cm(-2). A 12-bit binary counter circuit composed of 96 gates was realized in an area of 360 mm(2). The reduction in size also brought an order of magnitude increase in speed. The frequency of a 13-stage ring oscillator increased from 2.6 Hz to 22.1 Hz, and the maximum clock frequency of a binary counter increased from 1/3 Hz to 6 Hz. PMID:25591784

  18. Transforming insect electromyograms into pneumatic muscle control

    NASA Astrophysics Data System (ADS)

    Rutter, Brandon; Mu, Laiyong; Ritzmann, Roy; Quinn, Roger

    2006-05-01

    Robots can serve as hardware models for testing biological hypotheses. Both for this reason and to improve the state of the art of robotics, we strive to incorporate biological principles of insect locomotion into robotic designs. Previous research has resulted in a line of robots with leg designs based on walking and climbing movements of the cockroach Blaberus discoidalis. The current version, Robot V, uses muscle-like Braided Pneumatic Actuators (BPAs). In this paper, we use recorded electromyograms (EMGs) to drive robot joint motion. A muscle activation model was developed that transforms EMGs recorded from behaving cockroaches into appropriate commands for the robot. The transform is implemented by multiplying the EMG by an input gain thus generating an input pressure signal, which is used to drive a one-way closed loop pressure controller. The actuator then can be modeled as a capacitance with input rectification. The actuator exhaust valve is given a leak rate, making the transform a leaky integrator for air pressure, which drives the output force of the actuator. We find parameters of this transform by minimizing the difference between the robot motion produced and that observed in the cockroach. Although we have not reproduced full-amplitude cockroach motion using this robot, results from evaluation on reduced-amplitude cockroach angle data strongly suggest that braided pneumatic actuators can be used as part of a physical model of a biological system.

  19. Continued Development and Improvement of Pneumatic Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in the first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel

  20. Cysticercosis in laboratory rabbits.

    PubMed

    Owiny, J R

    2001-03-01

    There are no data on the current incidence of Taenia pisiformis in laboratory rabbits. Two cases of cysticercosis most likely due to T. pisiformis in laboratory rabbits (intermediate host) are presented. Both rabbits had no contact with dogs (final host); their caretakers did not work with dogs, and these caretakers changed into facility scrubs and wore gloves when working with the rabbits. Rabbit 1 may have been infected after being fed hay at our facility. In light of the life cycle of the parasite and the history of rabbit 2, it potentially could have been infected prior to arrival at our facility. There have been only three cases of tapeworm cysts in rabbits in our facility (average daily census, 250) during the last 10 years (incidence, < 1%). This report indicates that although cysticercosis is rare in laboratory rabbits, one should always be aware of such incidental findings. Although it may not produce overt illness in the rabbit, hepatic migration could adversely affect the outcome of some experimental procedures PMID:11300689

  1. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  2. Asymmetric pneumatization of the petrous apex.

    PubMed

    Roland, P S; Meyerhoff, W L; Judge, L O; Mickey, B E

    1990-07-01

    Three patients with high-intensity MR signals from one petrous apex, but nonpathologic fine-cut computed tomography are reported. In two of the three patients, normal bone marrow within the petrous apex on one side is believed to have generated the high-intensity signal. In one of the three patients, the etiology of the MR image remains obscure, but may represent the earliest stages of petrous cholesterol granuloma or mucocele. We have reviewed 500 head CT scans performed for non-otologic reasons, in an attempt to establish the frequency of this finding. The literature on MR and CT imaging of the petrous apex and asymmetric pneumatization of the petrous apex is reviewed. PMID:2117735

  3. Pneumatic grading applied to sugarcane products

    SciTech Connect

    Roka A., G.A.; Boisan C., M.A.; Frolov, V.F.

    1988-09-10

    There are secondary products from processing sugar cane, consisting of light particles having irregular elongated forms and falling into various size fractions: bagasso up to 5 mm, bagassilo 5-0.3 mm, and meole < 0.3 mm. These contain water, since they are obtained in the early stages of making cane sugar. Much of the bagasso and bagassilo is burned in situ in steam boilers at the sugar plants. Also, the various fractions are used in making paper, wood-straw board, and as ingredients for fodder and fertilizers, in addition to raw material in furfural production. These uses require grading and drying. In pneumatic grading, one uses the outgoing combustion products from the steam boilers at the plants and at the same time provides drying. Experiments were conducted in order to perform design calculations on grading these products.

  4. Optimizing pneumatic conveying of biomass materials

    NASA Astrophysics Data System (ADS)

    DiCianni, Matthew Edward Michael

    2011-12-01

    Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.

  5. Astroviruses in Rabbits

    PubMed Central

    Moschidou, Paschalina; Pinto, Pierfrancesco; Catella, Cristiana; Desario, Constantina; Larocca, Vittorio; Circella, Elena; Bànyai, Krisztian; Lavazza, Antonio; Magistrali, Chiara; Decaro, Nicola; Buonavoglia, Canio

    2011-01-01

    By screening rabbits with enterocolitis or enteritis complex and asymptomatic rabbits, we identified a novel astrovirus. The virus was distantly related (19.3%–23.7% aa identity) in the capsid precursor to other mammalian astroviruses within the Mamastrovirus genus. By using real-time reverse transcription PCR, with specific primers and probes and targeting a conserved stretch in open reading frame 1b, we found rabbit astrovirus in 10 (43%) of 23 samples from animals with enteric disease and in 25 (18%) of 139 samples from asymptomatic animals in Italy during 2005–2008. The mean and median titers in the positive animals were 102× and 103× greater, respectively, in the symptomatic animals than in the asymptomatic animals. These findings support the idea that rabbit astroviruses should be included in the diagnostic algorithm of rabbit enteric disease and animal experiments to increase information obtained about their epidemiology and potential pathogenic role. PMID:22172457

  6. 23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  7. PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR AREA TO REMOVE ANY EXCESS OR LOOSE SAND. - Stockham Pipe & Fittings Company, Ductile Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  8. A PNEUMATIC CONVEYING TEST RIG FOR MUNICIPAL SOLID WASTE FRACTIONS

    EPA Science Inventory

    This report analyzes the material properties and system parameters relevant to the pneumatic conveying of municipal solid waste and its processed fractions. Comparisons are made with the conveying of conventional industrial feedstocks, and a rationale for sizing and specification...

  9. Detail, north end of console and pneumatic tube message port, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, north end of console and pneumatic tube message port, also showing mirror to reflect view of communications switchboard - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  10. 14 CFR 25.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the maximum normal operating pressure. (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and proof pressure...

  11. Dynamic behavior of valves with pneumatic chamber for reciprocating compressors

    NASA Astrophysics Data System (ADS)

    Kato, M.; Kurohashi, M.; Aoshima, M.

    1993-10-01

    This paper describes the dynamic behavior of valves with pneumatic chambers for reciprocating compressors. These are known as 'damped valves' and are capable of reducing the impact on the valve seat and valve stopper. The characteristics of the dynamic behavior of the damped valves were clarified by calculating newly derived governing equations of valve dynamics. From the calculated results, it becomes apparent that the volume of the pneumatic chambers and the clearance between the pneumatic chamber and the valve have a large influence on the impact speed of the valves. Furthermore, the valves tend to close later for a higher compressor speed to oscillate at a larger amplitude for a lower density of gas such as hydrogen. These tendencies show that the selection of the specification of damped valves is very important. The stiffness of the valve spring and the lift of the valve also affect valve behavior as with valves without pneumatic chambers.

  12. 118. TUBING AT BACK SIDE OF PNEUMATIC SUPPLY PANEL IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    118. TUBING AT BACK SIDE OF PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  14. Inline evenflow material distributor for pneumatic material feed systems

    DOEpatents

    Thiry, Michael J.

    2007-02-20

    An apparatus for reducing clogs in a pneumatic material feed line, such as employed in abrasive waterjet machining systems, by providing an evenflow feed of material therethrough. The apparatus preferably includes a hollow housing defining a housing volume and having an inlet capable of connecting to an upstream portion of the pneumatic material feed line, an outlet capable of connecting to a downstream portion of the pneumatic material feed line, and an air vent located between the inlet and outlet for venting excess air pressure out from the housing volume. A diverter, i.e. an impingement object, is located at the inlet and in a path of incoming material from the upstream portion of the pneumatic material feed line, to break up clumps of ambient moisture-ridden material impinging on the diverter. And one or more filter screens is also preferably located in the housing volume to further break up clumps and provide filtering.

  15. Dry ice plug for hydraulic and pneumatic pipe flushing

    NASA Technical Reports Server (NTRS)

    Francino, L.; Rauch, S.

    1972-01-01

    Development of technique to clear blockages in hydraulic and pneumatic pipes is discussed. Technique consists of using dry ice plug to separate sensitive components from flushing fluid. Diagram of equipment and principles of operation are presented.

  16. Safety aspects of pneumatic transport. Information Circular/1985

    SciTech Connect

    Bowers, E.T.

    1985-01-01

    The work reported here deals with the safety aspects of pneumatic transport of underground coal, as well as the hazards inherent in more conventional haulage systems. Included are three designs for different applications of pneumatic haulage: off-loading a continuous-mining machine on a room-and-pillar section, vertical hoisting through a 1,200-ft shaft, and off-loading a tunnel-boring machine driving a 2,000-ft tunnel.

  17. High-Torque, Lightweight, Pneumatically Driven Wrench For Small Spaces

    NASA Technical Reports Server (NTRS)

    Miller, Thomas W.

    1995-01-01

    Pneumatically driven wrench provides torque up to 3,000 lb. per ft. in small space. Designed to reach into 2.6 x 2.75 x 6 in. pocket. Weighs approximately 25 lbs. Includes reversible pneumatic motor (electric motor could be used instead) and slip clutch. Also includes device indicating total angle through which wrench turned bolt or nut. This feature used for turn-of-the-nut tightening method.

  18. Evaluation of neutron flux parameters in irradiation sites of research reactor using the Westcott-formalism for the k0 neutron activation analysis method

    NASA Astrophysics Data System (ADS)

    Kasban, H.; Hamid, Ashraf

    2015-12-01

    Instrumental Neutron Activation Analysis using k0 (k0-INAA) method has been used to determine a number of elements in sediment samples collected from El-Manzala Lake in Egypt. k0-INAA according to Westcott's formalism has been implemented using the complete irradiation kit of the fast pneumatic rabbit and some selected manually loaded irradiation sites for short and long irradiation at Egypt Second Research Reactor (ETRR-2). Zr-Au and Co sets as neutron flux monitors are used to determine the neutron flux parameters (f and α) in each irradiation sites. Two reference materials IAEA Soil-7 samples have been inserted and implemented for data validation and an internal monostandard multi monitor used (k0 based IM-NAA). It was given a good agreement between the experimental analyzed values and that obtained of the certified values. The major and trace elements in the sediment samples have been evaluated with the use of Co as an internal and Au as an external monostandard comparators. The concentrations of the elements (Cr, Mn and Zn) in the sediment samples of the present work are discussed regarding to those obtained from other sites.

  19. Development of pneumatic actuator with low-wave reflection characteristics

    NASA Astrophysics Data System (ADS)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  20. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  1. A New Type of Motor: Pneumatic Step Motor.

    PubMed

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2007-02-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  2. Hepatitis E Virus in Farmed Rabbits, Wild Rabbits and Petting Farm Rabbits in the Netherlands.

    PubMed

    Burt, Sara A; Veltman, Jorg; Hakze-van der Honing, Renate; Schmitt, Heike; van der Poel, Wim H M

    2016-09-01

    Rabbits have been suggested as a zoonotic source of Hepatitis E virus. Phylogenetic analysis of HEV isolates from farmed, wild and pet rabbits in the Netherlands (23, 0, and 60 % respectively) showed them to be grouped amongst published rabbit HEV sequences and distinct from most human isolates. Dutch rabbits are unlikely to be a zoonotic source. PMID:27147250

  3. Oil well rabbit

    SciTech Connect

    Yerian, H.W.

    1983-10-18

    A well rabbit is described which has a high gas seal capacity as well as resistance to wear and structural failure. The rabbit comprises a one-piece elongated generally cylindrical body having external circumferential gas-sealing grooves spaced along its length and a set of helically oriented slots at its lower end. The circumferential grooves, which work collectively in the manner of a labyrinth seal, are undercut in a way to deflect escaping gas streams and promote turbulence to enhance their gas-sealing capability. The undercut profile and relative spacing of the grooves leaves a large surface area between the grooves for distributing radial forces and thereby decreasing the wear rate of the rabbit. The helically oriented slots convert energy of upward escaping gas into rotational energy in the rabbit. (3 claims.

  4. Novel bocaparvoviruses in rabbits.

    PubMed

    Lanave, G; Martella, V; Farkas, S L; Marton, S; Fehér, E; Bodnar, L; Lavazza, A; Decaro, N; Buonavoglia, C; Bányai, K

    2015-11-01

    Bocaparvovirus is a newly established genus within the family Parvoviridae and has been identified as a possible cause of enteric, respiratory, reproductive/neonatal and neurological disease in humans and several animal species. In this study, metagenomic analysis was used to identify and characterise a novel bocaparvovirus in the faeces of rabbits with enteric disease. To assess the prevalence of the novel virus, rectal swabs and faecal samples obtained from rabbits with and without diarrhoea were screened with a specific PCR assay. The complete genome sequence of the novel parvovirus was reconstructed. The virus was distantly related to other bocaparvoviruses; the three ORFs shared 53%, 53% and 50% nucleotide identity, respectively, to homologous genes of porcine bocaparvoviruses. The virus was detected in 8/29 (28%) and 16/95 (17%) samples of rabbits with and without diarrhoea, respectively. Sequencing of the capsid protein fragment targeted by the diagnostic PCR identified two distinct bocaparvovirus populations/sub-types, with 91.7-94.5% nucleotide identity to each other. Including these novel parvoviruses in diagnostic algorithms of rabbit diseases might help inform their potential pathogenic role and impact on rabbit production and the virological profiles of laboratory rabbits. PMID:26383859

  5. Viral diseases of the rabbit.

    PubMed

    Krogstad, Aric P; Simpson, Janet E; Korte, Scott W

    2005-01-01

    Viral disease in the rabbit is encountered infrequently by the clinical practitioner; however, several viral diseases were reported to occur in this species. Viral diseases that are described in the rabbit primarily may affect the integument, gastrointestinal tract or, central nervous system or maybe multi-systemic in nature. Rabbit viral diseases range from oral papillomatosis, with benign clinical signs, to rabbit hemorrhagic disease and myxomatosis, which may result in significant clinical disease and mortality. The wild rabbit may serve as a reservoir for disease transmission for many of these viral agents. In general, treatment of viral disease in the rabbit is supportive in nature. PMID:15585192

  6. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    SciTech Connect

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  7. Salivary Stone Pneumatic Lithotripsy in a Live Porcine Model.

    PubMed

    Walvekar, Rohan R; Hoffman, Henry T; Kolenda, Jack; Hernandez, Stephen

    2016-06-01

    The purpose of this study is to evaluate the efficacy of endoscopic fragmentation and removal of artificial calculi in a live porcine model employing intracorporeal pneumatic lithotripsy. In this experimental study, 7 submandibular ducts were accessed and artificial calculi placed. A salivary pneumatic lithotripter probe was inserted through an interventional sialendoscope to fragment the calculi. A salivary duct catheter was then used to flush stone fragments, followed by endoscopy to assess complete fragmentation and ductal trauma. Ultimately, 7 artificial stones (3-10 mm, 4F/5F) were successfully fragmented without causing significant endoluminal trauma. Number of pulses for adequate stone fragmentation averaged 20 (range, 5-31). In all cases, stone fragments were successfully flushed out with the salivary duct catheter. Postprocedure endoscopy confirmed ductal integrity in all 7 ducts. While more studies are needed, this preliminary animal model demonstrates efficacy of endoscopic pneumatic lithotripsy for the management of sialolithiasis. PMID:27048662

  8. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  9. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  10. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  11. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... tubing; (2) Beams or girders extending below the ceiling or other obstructions do not detract from...

  12. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  13. Evaluation of a pneumatic Martian soil sampler concept

    NASA Technical Reports Server (NTRS)

    Schaefer, John L.; Neathery, James K.; Stencel, John M.

    1994-01-01

    The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

  14. Photodynamic therapy on normal rabbit mandible

    NASA Astrophysics Data System (ADS)

    Fan, Kathleen F.; Hopper, Colin; Speight, Paul M.; Davies, Claire; Bown, Stephen G.

    1995-03-01

    Photodynamic therapy has been proposed as an intra-operative adjunct to surgical resection of tumors invading bone. To assess this, we studied the effects of PDT in normal bone. Forty- four rabbits were sensitized with Photofrin 3 mg/kg, 5-aminolaevulinic acid (ALA) 400 mg/kg, or meso-tetrahydroxyphenylchlorin (mTHPC) 0.3 mg/kg. A mandibular incisor was removed and the socket irradiated with a cylindrical diffusion fiber (630 nm Photofrin and ALA, 650 nm mTHPC, 100 J per treatment). Irradiation was given 1 or 48 hours after Photofrin, 72 hours after mTHPC, whilst 2 doses were given 2.5 and 4 hours after the first fractionated dose of ALA. The socket of the ipsilateral maxillary incisor was used as a nonirradiated control to assess healing without PDT. Other controls assessed healing after irradiation of unsensitized animals. Rabbits were killed 3, 10, and 21 days after treatment. Tooth socket healing appeared to be the same in all groups of animals with evidence of woven bone formation by 10 days. We conclude that PDT is unlikely to have any effect on healing in normal bone, which makes it suitable for treating tumors invading bone.

  15. Assessing a pneumatic fractionator as a lint cleaning device

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A study assessed a pneumatic fractionator as a lint cleaning device for ginned lint. Results from a test that used two line pressures and three fractionation times showed that higher line pressure and longer fractionation time produced fiber that was shorter in staple length, contained more neps, a...

  16. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  17. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  18. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  19. The Pneumatic Common: Learning in, with and from the Air

    ERIC Educational Resources Information Center

    Ford, Derek R.

    2015-01-01

    Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…

  20. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  1. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  2. Note: Pneumatically modulated liquid delivery with feedback control

    NASA Astrophysics Data System (ADS)

    Field, C. R.; Terray, A. V.; Lubrano, A. L.; Rogers, D. A.; Hart, S. J.; Rose-Pehrsson, S. L.

    2012-07-01

    We present the design and characterization of a pneumatically driven liquid delivery system using an embedded microcontroller with feedback control capable of maintaining a stable, constant flow rate over several hours of operation. Flow rates with relative standard deviations less than 1% were achieved and compared to a typical laboratory syringe pump.

  3. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... paraplegics walk. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the Food... distribution before May 28, 1976. Any other rigid pneumatic structure orthosis shall have an approved PMA or...

  4. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... paraplegics walk. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the Food... distribution before May 28, 1976. Any other rigid pneumatic structure orthosis shall have an approved PMA or...

  5. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  6. 7 CFR 3201.86 - Pneumatic equipment lubricants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Pneumatic equipment lubricants. 3201.86 Section 3201.86 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF PROCUREMENT AND PROPERTY MANAGEMENT, DEPARTMENT OF AGRICULTURE GUIDELINES FOR DESIGNATING BIOBASED PRODUCTS FOR FEDERAL PROCUREMENT Designated Items § 3201.86...

  7. 14 CFR 23.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... elements must be burst pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the maximum normal operating pressure. (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and proof pressure tested to 1.5 times, the maximum normal operating pressure. (c) An analysis, or...

  8. Pneumatic Power Drive Wheel and related assembly for Turntable, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic Power Drive Wheel and related assembly for Turntable, with scale. Not in use August 1994. Turntable rotated with engine and tender on balance by two persons, one on either side at ground level - East Broad Top Railroad & Coal Company, Roundhouse, State Route 994, West of U.S. Route 522, Rockhill Furnace, Huntingdon County, PA

  9. Adaptive backstepping slide mode control of pneumatic position servo system

    NASA Astrophysics Data System (ADS)

    Ren, Haipeng; Fan, Juntao

    2016-06-01

    With the price decreasing of the pneumatic proportional valve and the high performance micro controller, the simple structure and high tracking performance pneumatic servo system demonstrates more application potential in many fields. However, most existing control methods with high tracking performance need to know the model information and to use pressure sensor. This limits the application of the pneumatic servo system. An adaptive backstepping slide mode control method is proposed for pneumatic position servo system. The proposed method designs adaptive slide mode controller using backstepping design technique. The controller parameter adaptive law is derived from Lyapunov analysis to guarantee the stability of the system. A theorem is testified to show that the state of closed-loop system is uniformly bounded, and the closed-loop system is stable. The advantages of the proposed method include that system dynamic model parameters are not required for the controller design, uncertain parameters bounds are not need, and the bulk and expensive pressure sensor is not needed as well. Experimental results show that the designed controller can achieve better tracking performance, as compared with some existing methods.

  10. Pneumatic vacuum tube message center, basement room 23, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  11. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  12. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. The Cutaneous Rabbit Revisited

    ERIC Educational Resources Information Center

    Flach, Rudiger; Haggard, Patrick

    2006-01-01

    In the cutaneous rabbit effect (CRE), a tactile event (so-called attractee tap) is mislocalized toward an adjacent attractor tap. The effect depends on the time interval between the taps. The authors delivered sequences of taps to the forearm and asked participants to report the location of one of the taps. The authors replicated the original CRE…

  14. Pneumatic fractures in Confined Granular Media

    NASA Astrophysics Data System (ADS)

    Eriksen, Fredrik K.; Toussaint, Renaud; Jørgen Måløy, Knut; Grude Flekkøy, Eirik; Turkaya, Semih

    2016-04-01

    We will present our ongoing study of the patterns formed when air flows into a dry, non-cohesive porous medium confined in a horizontal Hele-Shaw cell. This is an optically transparent system consisting of two glass plates separated by 0.5 to 1 mm, containing a packing of dry 80 micron beads in between. The cell is rectangular and has an air-permeable boundary (blocking beads) at one short edge, while the other three edges are completely sealed. The granular medium is loosely packed against the semi-permeable boundary and fills about 80 % of the cell volume. This leaves an empty region at the sealed side, where an inlet allows us to set and maintain the air at a constant overpressure (0.1 - 2 bar). For the air trapped inside the cell to relax its overpressure it has to move through the deformable granular medium. Depending on the applied overpressure and initial density of the medium, we observe a range of different behaviors such as seepage through the pore-network with or without an initial compaction of the solid, formation of low density bubbles with rearrangement of particles, granular fingering/fracturing, and erosion inside formed channels/fractures. The experiments are recorded with a high-speed camera at a framerate of 1000 images/s and a resolution of 1024x1024 pixels. We use various image processing techniques to characterize the evolution of the air invasion patterns and the deformations in the surrounding material. The experiments are similar to deformation processes in porous media which are driven by pore fluid overpressure, such as mud volcanoes and hydraulic or pneumatic (gas-induced) fracturing, and the motivation is to increase the understanding of such processes by optical observations. In addition, this setup is an experimental version of the numerical models analyzed by Niebling et al. [1,2], and is useful for comparison with their results. In a directly related project [3], acoustic emissions from the cell plate are recorded during

  15. a Study of the Systematics of Low-Lying Levels in Nuclei in the Mass Region A=80 with a NIM Controlled Rabbit System.

    NASA Astrophysics Data System (ADS)

    Fry, Leolan Harold, Jr.

    Heavy ion reactions were used to produce nuclei away from beta stability in the mass region A(TURNEQ)80. The irradiated targets were transported to an isolated detector site using a rapid target transfer (Rabbit) system to aid in the study of weak products produced in these reactions and to protect the Ge(Li) detectors used in the experiments. The "Rabbit" system constructed for this purpose was a pneumatic type and was controlled by a NIM controller. The NIM controller, a unique feature of this system, was constructed with TTL and CMOS circuits and works in conjunction with a leaky integrator and a UNIVAC 6130 computer. The "Rabbit" system was used in lifetime, gamma-gamma coincidence measurements and beta-gamma coincidence measurements. Lifetime measurements were used to study the decay of ('79)Sr produced in the reaction ('54)Fe + ('28)Si at 90 MeV (lab). The lifetime of the ground state of ('79)Sr was measured and a positron feeding to the 39.3-keV level in ('79)Rb was established. Lifetime measurements were also used to study the decay of ('81m)Rb, which is produced in the reaction ('68)Zn + ('16)O at 56 MeV (lab). A positron feeding from the isomeric level in ('81)Rb to the 49.6 -keV level in ('81)Kr was established. In addition, lifetime measurements were used to help identify gamma rays produced in the reactions ('68)Zn + ('16)O and ('70)Ge + ('16)O at 56 MeV (lab). The reaction ('68)Zn + ('16)O was also studied with the gamma-gamma coincidence technique. Extensive level schemes were constructed and new levels were established for the decays of ('81)Rb and ('81)Sr. The beta-gamma coincidence technique was used in the study of the reaction ('70)Ge + ('16)O to investigate the ground state and isomeric levels of ('83)Y and ('84)Y. The order and relative separation of these levels were tentatively established for ('83)Y. The Q-value and J('(pi)) of the ground state were established and tentative J('(pi)) assignments were made for the isomeric levels in ('84)Y

  16. Rabbit care and husbandry.

    PubMed

    Bradley, Teresa

    2004-05-01

    This article provides information for the veterinary staff to be better prepared to care for the special needs of rabbit patients as they are presented in increased frequency for veterinary care. Housing, nutrition,restraint, and recognizing illness are covered in detail. Descriptions of techniques for blood collection, oral medication administration, and injection sites are included. Preventive care recommendations for examinations from first visit to geriatric visits are outlined as well as indications for spaying and neutering. Also provided are lists that will aid the veterinary staff in providing instructions when the appointment is made, recommendations for boarding, surgical, and anesthetic considerations and clinical signs that are associated with pain in rabbits. PMID:15145392

  17. Rabbits killing birds revisited.

    PubMed

    Zhang, Jimin; Fan, Meng; Kuang, Yang

    2006-09-01

    We formulate and study a three-species population model consisting of an endemic prey (bird), an alien prey (rabbit) and an alien predator (cat). Our model overcomes several model construction problems in existing models. Moreover, our model generates richer, more reasonable and realistic dynamics. We explore the possible control strategies to save or restore the bird by controlling or eliminating the rabbit or the cat when the bird is endangered. We confirm the existence of the hyperpredation phenomenon, which is a big potential threat to most endemic prey. Specifically, we show that, in an endemic prey-alien prey-alien predator system, eradication of introduced predators such as the cat alone is not always the best solution to protect endemic insular prey since predator control may fail to protect the indigenous prey when the control of the introduced prey is not carried out simultaneously. PMID:16529776

  18. Electromyographic changes in postmeniscectomy patients. Role of the pneumatic tourniquet.

    PubMed

    Weingarden, S I; Louis, D L; Waylonis, G W

    1979-03-23

    Delayed rehabilitation in postmeniscectomy patients may be due to a slowly resolving axonal compression syndrome secondary to the use of the pneumatic tourniquet. Twenty-five patients who underwent meniscectomy were examined to determine whether the pneumatic tourniquet used during the procedure caused a neurological dificit detectable by electromyography (EMG). Of these, 18 had postsurgical EMG changes that eventually resolved. Analysis of the data suggests a relationship between the occurrence of EMG abnormalities, the duration of the tourniquet inflation during surgery, and patient's recovery time. Quadricep muscle weakness after knee surgery has generally been attributed to disuse atrophy. In an attempt to prevent this problem, patients participate in a quadriceps exercise program, if possible, before surgery, with continuation after surgery. The persistence of weakness has been believed to be secondary to inadequate exercise. PMID:581679

  19. Pneumatic protection applied to an airbag for para-gliders

    NASA Astrophysics Data System (ADS)

    Raievski, V.; Valladas, G.

    1998-02-01

    We present a theory of pneumatic protection based on the laws of thermodynamics, elasticity and fluid mechanics. A general pneumatic protection system is made up of several communicating compartments, the differences in pressure of the compartments generating a transfer of mass and energy between them. The transfer offers interesting possibilities to improve the performance of the system. An example of this type of protection in aerial sport is the airbag for para-gliders, it is used in this paper to illustrate the theory. As the pressure in the airbag depends uniquely on its volume, the geometric model in the theory can be simplified. Experiments carried out with crash-test dummies equipped with sensors have confirmed the theoretical predictions.

  20. Performance characterization of pneumatic single pellet injection system

    SciTech Connect

    Schuresko, D.D.; Milora, S.L.; Hogan, J.T.; Foster, C.A.; Combs, S.K.

    1982-01-01

    The Oak Ridge National Laboratory single-shot pellet injector, which has been used in plasma fueling experiments on ISX and PDX, has been upgraded and extensively instrumented in order to study the gas dynamics of pneumatic pellet injection. An improved pellet transport line was developed which utilizes a 0.3-cm-diam by 100-cm-long guide tube. Pellet gun performance was characterized by measurements of breech and muzzle dynamic pressures and by pellet velocity and mass determinations. Velocities up to 1.4 km/s were achieved for intact hydrogen pellets using hydrogen propellant at 5-MPa breech pressure. These data have been compared with new pellet acceleration calculations which include the effects of propellant friction, heat transfer, time-dependent boundary conditions, and finite gun geometry. These results provide a basis for the extrapolation of present-day pneumatic injection system performance to velocities in excess of 2 km/s.

  1. Development of pneumatic thrust-deflecting powered-lift systems

    NASA Technical Reports Server (NTRS)

    Englar, R. J.; Nichols, J. H., Jr.; Harris, M. J.; Eppel, J. C.; Shovlin, M. D.

    1986-01-01

    Improvements introduced into the Circulation Control Wing/Upper Surface Blowing (CCW/USB) STOL concept (Harris et al., 1982) are described along with results of the full-scale static ground tests and model-scale wind tunnel investigations. Tests performed on the full-scale pneumatic thrust-deflecting system installed on the NASA QSRA aircraft have demonstrated that, relative to the original baseline configuration, a doubling of incremental thrust deflection due to blowing resulted from improvements that increased the blowing span and momentum, as well as from variations in blowing slot height and geometry of the trailing edge. A CCW/Over the Wing model has been built and tested, which was shown to be equivalent to the CCW/USB system in terms of pneumatic thrust deflection and lift generation, while resolving the problem of cruise thrust loss due to exhaust scrubbing on the wing upper surface.

  2. Liquid-metal dip seal with pneumatic spring

    DOEpatents

    Poindexter, Allan M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.

  3. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  4. Nonlinear Vibrational Behaviour of an Elasto-Pneumatic Training Tool

    NASA Astrophysics Data System (ADS)

    Körner, Claudia; Hetzler, Hartmut; Seemann, Wolfgang

    This paper deals with the nonlinear vibrational response of a stepping-board with nonlinear elasto-pneumatic force elements. Experimental investigations often show too high vertical ground reaction forces (VGRF) between the test persons and the training tool during exercises. The goal of this contribution is to identify the main factors of the dynamical behaviour and thus the biomechanical impact on humans of this training tool. Therefore this paper presents a mechanical model in order to investigate the interaction between the nonlinear behaviour of the board and the athlete. The multiphysical modelling consists of the linear-elastic structural stiffness part and the nonlinear part due to the pneumatic components. This leads to a nonlinear ordinary differential equation.

  5. Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy

    PubMed Central

    Zhang, Lin; Zhou, Yiwu

    2015-01-01

    Abstract Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before. We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output. This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism. PMID:26222867

  6. Evaluation of the pneumatic tube system for transportation of packed red cell units

    PubMed Central

    Dhar, Supriya; Basu, Sabita; Chakraborty, Subhosmito; Sinha, Subir

    2015-01-01

    Background: Pneumatic tube system (PTS) is commonly used in hospital settings to transport blood samples to diagnostic laboratories. At our blood center, we receive blood requisitions via the PTS, but units are carried to the ward by human courier. Recently we considered using the PTS for transporting blood units. Since, there are reports of hemolysis in blood samples sent through the PTS, we evaluated this system for transporting red cell units. Aims: The aim was to assess the effect of PTS transport on the quality of packed red cell units. Materials and Methods: A total of 50 red blood cells units (RBC), (25 non-irradiated and 25 irradiated) were subjected to transportation through the PTS. The control arm in the study was age-matched RBC units not subjected to PTS transport. Each RBC unit was evaluated for hemoglobin (Hb), lactate dehydrogenase, potassium and plasma hemoglobin (Hb). The paired t-test was used to compare these parameters, and the P value was calculated. Results and Conclusion: The percentage of hemolysis after transportation through PTS was below the recommended guidelines. Delivery of the blood unit to the wrong station, bags lying unattended at the destination were few of the problems that had to be addressed. To conclude, though the PTS is a safe means of transporting blood products with reduction in the turn-around-time, it must be validated before use. PMID:26420944

  7. Electric versus pneumatic power in hand prostheses for children.

    PubMed

    Plettenburg, D H

    1989-01-01

    Most externally powered hand prostheses for children with a unilateral congenital below-elbow amputation are myoelectrically controlled. All of them are electrically powered. Despite the success of fitting children with this kind of prostheses, there are some disadvantages: prosthetic weight is high, operating speed is low, the system is vulnerable and its size prohibits fitting it to patients with a long fore-arm stump. It will be shown that pneumatic power can overcome most of these disadvantages. PMID:2733004

  8. Comprehensive integration of homogeneous bioassays via centrifugo-pneumatic cascading.

    PubMed

    Godino, Neus; Gorkin, Robert; Linares, Ana V; Burger, Robert; Ducrée, Jens

    2013-02-21

    This work for the first time presents the full integration and automation concept for a range of bioassays leveraged by cascading a centrifugo-pneumatic valving scheme to sequentially move several liquids through shared channel segments for multi-step sample preparation into the detection zone. This novel centrifugo-pneumatic liquid handling significantly simplifies system manufacture by obviating the need for complex surface functionalization procedures or hybrid material integration, as it is common in conventional valving methods such as capillary burst valves or sacrificial valves. Based on the centrifugo-pneumatic valving scheme, this work presents a toolkit of operational elements implementing liquid loading/transfer, metering, mixing and sedimentation in a microstructured polymer disc. As a proof of concept for the broad class of homogeneous bioassays, the full integration and automation of a colorimetric nitrate/nitrite test for the detection of clinically relevant nitric oxide (NO) in whole blood is implemented. First, 40 μL of plasma is extracted from a 100 μL sample of human blood, incubated for one hour with the enzymatic mixture (60 μL), and finally reacted with 100 μL of colorimetric (Greiss) reagents. Following just a single loading phase at the beginning of the process, all of these steps are automated through the centrifugo-pneumatic cascade with a high level of flow control and synchronization. Our system shows good correlation with controls up to 50 μM of nitrate, which adequately covers the healthy human range (4 to 45.3 μM). PMID:23250328

  9. A pneumatic sample changer for gamma-ray spectroscopy

    USGS Publications Warehouse

    Massoni, C.J.; Fones, R.V.; Simon, F.O.

    1973-01-01

    A gravity-feed, pneumatic-ejection sample changer has been developed. The changer is suitable for both flat and well-type detectors and permits the continuous use of gamma-ray spectroscopy equipment 24 h a day, 7 days a week. The electronic circuitry has a fail-safe feature which stops the operation of the changer if a malfunction occurs. ?? 1973 The American Institute of Physics.

  10. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  11. Biodegradable fixation of rabbit osteotomies.

    PubMed

    Vainionpää, S; Vihtonen, K; Mero, M; Pätiälä, H; Rokkanen, P; Kilpikari, J; Törmälä, P

    1986-06-01

    Osteotomies of the tibial diaphysis were operatively fixed with biodegradable implants in 44 rabbits. Polyglycolic acid (PGA)/polylactic acid (PLA) copolymer implants reinforced with 7 per cent carbon fibre and overlaid with gold were used in 24 rabbits. Poly-beta-hydroxy butyric acid (PHBA) with carbon fibre reinforcement and gold surfacing were used in 20 rabbits. No external support was used. Unsatisfactory results were achieved with the PGA/PLA copolymer implants. Better results were achieved in 15 out of 20 rabbits whose osteotomies were fixed with carbon fibre-reinforced PHBA implants. PMID:3739665

  12. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  13. Evaluation of unsaturated zone air permeability through pneumatic tests

    USGS Publications Warehouse

    Baehr, Arthur L.; Hult, Marc F.

    1991-01-01

    Predicting the steady state distribution of air pressure in the unsaturated zone resulting from a pneumatic test provides a method for determining air-phase permeability. This technique is analogous to the inverse problem of well hydraulics; however, air flow is more complicated than ground water flow because of air compressibility, the Klinkenberg effect, variations in air density and viscosity that result from temperature fluctuations in the unsaturated zone and the possibility of inducing water movement during the pneumatic test. An analysis of these complicating factors reveals that, when induced water movement can be neglected, a linear version of the airflow equation can provide an appropriate approximation for the purpose of determining air-phase permeability. Two analytical solutions for steady state, two-dimensional, axisymmetric airflow to a single well partially screened in the unsaturated zone are developed. One solution applies where there is a stratum of relatively low air permeability, separating the stratum in which the well is completed, from the atmosphere. The other solution applies where there is no separating stratum between the domain and atmosphere. In both situations the water table forms the lower horizontal boundary. Applications of both solutions to determine air permeability from data collected during pneumatic tests are presented.

  14. Characterization of sprays for thermo-stabilized pneumatic nebulizer.

    PubMed

    Ochowiak, M; Doligalski, M; Broniarz-Press, L; Matuszak, M; Gościniak, A

    2016-03-31

    The research presents the nebulizer spray chamber temperature controller responsible for controlling temperature of aerosol produced as a result of nebulizing process. The motivation to make an attempt to improve modern pneumatic devices was the shortage of this kind of apparatuses on the market allowing the production of thermos aerosol. A designed temperature controlling system for pneumatic nebulizers aims at increasing and stabilizing temperature of produced aerosols and increasing aerosol therapy safety. The system is intended for producing aerosol in the process of pneumatic nebulization with the temperature similar to that of the human body. Experiments that were carried out confirmed good performance of the device. It was proved that with the increase of temperature the amount of big droplets fall and the entire spectrum of the droplet diameter moves towards smaller droplet diameter values. Reduction of liquid viscosity related to the increase of temperature leads to the reduction of droplet diameter and, as a result, the reduction of the Sauter mean diameter value. PMID:26825254

  15. Design, modeling and fabrication of a constant flow pneumatic micropump

    NASA Astrophysics Data System (ADS)

    Inman, Walker; Domansky, Karel; Serdy, James; Owens, Bryan; Trumper, David; Griffith, Linda G.

    2007-05-01

    This paper characterizes a bi-directional pneumatic diaphragm micropump and presents a model for performance of an integrated fluidic capacitor. The fluidic capacitor is used to convert pulsatile flow into a nearly continuous flow stream. The pump was fabricated in acrylic using a CNC mill. The stroke volume of the pump is ~1 µL. The pump is self-priming, bubble tolerant and insensitive to changes in head pressure and pneumatic pressure within its operating range. The pump achieves a maximum flow rate of 5 mL min-1 against zero head pressure. With pneumatic pressure set to 40 kPa, the pump can provide flow at 2.6 mL min-1 against a head pressure of 25 kPa. A nonlinear model for the capacitor was developed and compared with experimental results. The ratio of the time constant of the capacitor to the cycle time of the pump is shown to be an accurate indicator of capacitor performance and a useful design tool.

  16. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  17. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    NASA Technical Reports Server (NTRS)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  18. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia

    PubMed Central

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-01-01

    Abstract Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6–120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients’ clinical symptom scores were calculated before and at 6 to 36 months, 37 to 60 months, and >60 months after therapy. The influence of the patients’ age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36 months after therapy, 21 cases for 37 to 60 months, and 5 cases for >60 months, and the patients’ symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36 months remission rate was 85.7% (30/35), the 37 to 60 months rate was 61.9% (13/21), and the >60 months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations

  19. [Is pneumatic sample transport system also a carrier for microorganisms?].

    PubMed

    Alpat, Saygin Nayman; Ozgüneş, Ilhan; Aybey, Aşkin Derya; Ertem, Osman Turgut; Akşit, Filiz

    2009-07-01

    The purpose of this study was to evaluate the possible infection and contamination risk of the pneumatic system used in our hospital and to establish essential infection control measures. The study was conducted in a quaternary health care center with 1.000 bed capacity. A total of 614 specimens were taken 2 times weekly from the pneumatic transport system and its carriers at 22 wards, 5 intensive care units, 3 laboratories, 2 blood taking units, and pharmacy. Samples were also obtained from the fingertips of 33 subjects using the system, before and after contact with the carriers. A questionnaire that consisted of 8 questions was applied to 224 subjects who worked in those units, evaluating the degree of compliance to the obligations for the cleaning of the pneumatic system and carriers and their approach in case of visible pollution at the system. Bacterial growth was observed in 15.2% (45/296) of samples in the 1st week and 7.6% (18/238) of the samples in the 2nd week, making a total of 11.8% (63/534) bacterial growth. No growth was detected from the areas where the carriers were placed. Of these 69.8% were coagulase negative staphylococci, 11.1% diphteroids, 7.9% Acinetobacter Iwoffii, 4.8% Staphylococcus aureus, 4.8% Bacillus spp. and 1.6% Enterococcus durans. Acinetobacter baumannii and Aspergillus were detected at two fingertip samples taken before the contact with carriers, while again A. baumannii and Enterobacter cloacae were detected at the samples following contact. Moreover, 31.3% of the subjects noted that they cleaned the carriers only if any visible contamination was present. In addition, 14.3% reported that they have encountered broken or spilled up material in the system for more than 5 times, 10.3% reported that they followed the instructions in case of presence of infected material inside the carriers, 23.7% reported that they always washed their hands after any contact with the carriers, 9.8% noted that they always used gloves during contact

  20. Formulation of a minimum variance deconvolution technique for compensation of pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1990-01-01

    Increasingly, aircraft system designs require that aerodynamic parameters derived from pneumatic measurements be employed as control-system feedbacks. Such high frequency pressure measurements' accuracy is compromised by pressure distortion due to frictional attenuation and pneumatic resonance within the sensing system. A pneumatic distortion model is here formulated and reduced to a low-order state-variable model which retains most of the full model's dynamic characteristics. This reduced-order model is coupled with standard results from minimum variance estimation theory to develop an algorithm to compensate for pneumatic-distortion effects.

  1. Pathogenicity of rotavirus in rabbits.

    PubMed Central

    Thouless, M E; DiGiacomo, R F; Deeb, B J; Howard, H

    1988-01-01

    The role of rotavirus in diarrheal disease of rabbits was investigated, and a model for human rotavirus infection was established. Orogastric inoculation of 8- and 12-week-old New Zealand White rabbits with a rabbit strain of rotavirus (L:ALA:84) resulted in fecal shedding of virus for 6 to 8 days from 2 to 5 days after inoculation. Most rabbits exhibited diarrhea, coincident with the onset of viral shedding, which persisted for 2 to 4 days. Diarrhea was characterized by soft or fluid stools and fecal staining of the perineum. Inoculation of 3-week-old rabbits resulted in a briefer period of viral shedding and diarrhea of a milder nature. Histopathologic examination during the period of viral shedding revealed a mild, nonsuppurative enteritis. Inoculated rabbits exhibited antibodies in serum to rotavirus by enzyme-linked immunosorbent assay. Sham-inoculated or uninoculated rabbits maintained in the same cage or the same room with inoculated rabbits acquired rotavirus infection. The mild diarrheal disease which resulted with a rotavirus isolate from severe field cases suggests that cofactors were involved. Images PMID:2838507

  2. Neuromuscular lesions in restrained rabbits.

    PubMed

    Mendlowski, B

    1975-01-01

    Ten of 16 rabbits restrained 6 h daily for 35 days developed focal to diffuse degeneration of the sciatic nerves. Very small necrotic areas also were found in the skeletal muscles of seven of 16 rabbits, but the muscle lesions did not correlate with the nerve changes. PMID:180647

  3. Pulmonary pneumaticity in the postcranial skeleton of extant aves: a case study examining Anseriformes.

    PubMed

    O'Connor, Patrick M

    2004-08-01

    Anseriform birds were surveyed to examine how the degree of postcranial pneumaticity varies in a behaviorally and size-diverse clade of living birds. This study attempts to extricate the relative effects of phylogeny, body size, and behavioral specializations (e.g., diving, soaring) that have been postulated to influence the extent of postcranial skeletal pneumaticity. One hundred anseriform species were examined as the focal study group. Methods included latex injection of the pulmonary apparatus followed by gross dissection or direct examination of osteological specimens. The Pneumaticity Index (PI) is introduced as a means of quantifying and comparing postcranial pneumaticity in a number of species simultaneously. Phylogenetically independent contrasts (PICs) were used to examine the relationship between body size and the degree of postcranial pneumaticity throughout the clade. There is a high degree of similarity (i.e., clade-specificity) within most anseriform subgroups. As a whole, Anseriformes demonstrate no significant relationship between relative pneumaticity and body size, as indicated by regression analysis of body mass on PI. It is apparent, however, that many clades of diving ducks do exhibit lower PIs than their nondiving relatives. By exclusion of diving taxa from analyses, a significant positive slope is observed and the hypothesis of relatively higher pneumaticity in larger-bodied birds is only weakly supported. However, low correlations indicate that factors other than body size account for much of the variation observed in relative pneumaticity. Pneumaticity profiles were mapped onto existing phylogenetic hypotheses. A reduction in the degree of postcranial pneumaticity occurred independently in at least three anseriform subclades specialized for diving. Finally, enigmatic pneumatic features located in distal forelimb elements of screamers (Anhimidae) result from invasion of bone by a network of subcutaneous air sac diverticula spreading

  4. Gait Using Pneumatic Brace for End-Stage Knee Osteoarthritis.

    PubMed

    Kapadia, Bhaveen H; Cherian, Jeffrey Jai; Starr, Roland; Chughtai, Morad; Mont, Michael A; Harwin, Steven F; Bhave, Anil

    2016-04-01

    More than 20 million individuals in the United States are affected by knee osteoarthritis (OA), which can lead to altered biomechanics and excessive joint loading. The use of an unloader pneumatic brace with extension assist has been proposed as a nonoperative treatment modality that may improve gait mechanics and correct knee malalignment. We assessed the following parameters in patients who have knee OA treated with and without a brace: (1) changes in temporospatial parameters in gait; (2) knee range of motion, knee extension at heel strike, and foot placement; (3) knee joint moments and impulse; and (4) changes in dynamic stiffness and rate of change of knee flexion during midstance to terminal stance. This 2:1 prospective, randomized, single-blinded trial evaluated 36 patients (24 brace and 12 matching). OA knee patients were randomized to receive either a pneumatic unloader brace or a standard nonoperative treatment regimen as the matching cohort for a 3-month period. They underwent evaluation of gait parameters using a three-dimensional gait analysis system at their initial appointment and at 3 months follow-up. All the testing, pre- and postbracing were performed without wearing the brace to examine for retained effects. Treatment with the brace led to significant improvements versus standard treatment in various gait parameters. Patients in the brace group had improvements in walking speed, knee extension at heel strike, total range of motion, knee joint forces, and rate of knee flexion from midstance to terminal stance when compared with the matching cohort. Knee OA patients who used a pneumatic unloader brace for 3 months for at least 3 hours per day had significant improvements various gait parameters when compared with a standard nonoperative therapy cohort. Braced patients demonstrated gait-modifying affects when not wearing the brace. These results are encouraging and suggest that this device represents a promising treatment modality for knee OA that

  5. Forces associated with pneumatic power screwdriver operation: statics and dynamics.

    PubMed

    Lin, Jia-Hua; Radwin, Robert G; Fronczak, Frank J; Richard, Terry G

    2003-10-10

    The statics and dynamics of pneumatic power screwdriver operation were investigated in the context of predicting forces acting against the human operator. A static force model is described in the paper, based on tool geometry, mass, orientation in space, feed force, torque build up, and stall torque. Three common power hand tool shapes are considered, including pistol grip, right angle, and in-line. The static model estimates handle force needed to support a power nutrunner when it acts against the tightened fastener with a constant torque. A system of equations for static force and moment equilibrium conditions are established, and the resultant handle force (resolved in orthogonal directions) is calculated in matrix form. A dynamic model is formulated to describe pneumatic motor torque build-up characteristics dependent on threaded fastener joint hardness. Six pneumatic tools were tested to validate the deterministic model. The average torque prediction error was 6.6% (SD = 5.4%) and the average handle force prediction error was 6.7% (SD = 6.4%) for a medium-soft threaded fastener joint. The average torque prediction error was 5.2% (SD = 5.3%) and the average handle force prediction error was 3.6% (SD = 3.2%) for a hard threaded fastener joint. Use of these equations for estimating handle forces based on passive mechanical elements representing the human operator is also described. These models together should be useful for considering tool handle force in the selection and design of power screwdrivers, particularly for minimizing handle forces in the prevention of injuries and work related musculoskeletal disorders. PMID:12933078

  6. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    SciTech Connect

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao; Jambovane, Sachin R.; Kelly, Ryan T.

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

  7. Model free control for differential pneumatic pistons: experimental comparison

    NASA Astrophysics Data System (ADS)

    Weist, Jens; Arteaga, Marco A.; de la Cruz, Leonardo R.; Hebisch, Holger

    2011-01-01

    PID controllers are widely used in industry. While this may be appropriate for many systems, eventually a more complex or reliable algorithm has to be designed to improve performance. Common praxis is to take advantage either of physical properties (e.g. passivity) or of a mathematical model. For this last case it may prove to be hard to get an accurate description of the system dynamics. In this article we experimentally analyse the behaviour of pneumatic actuators by employing control algorithms available in the literature with little or no model information at all, including an adaptation of a robot control law which is shown to work very well for the test bed.

  8. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  9. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials...

  10. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials...

  11. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials...

  12. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials...

  13. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  14. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  15. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  16. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  17. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  18. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... design temperature (see UG-21 of section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01-1)). In no case shall the pneumatic test pressure exceed one and one... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be...

  19. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... design temperature (see UG-21 of section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01-1)). In no case shall the pneumatic test pressure exceed one and one... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be...

  20. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... design temperature (see UG-21 of section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01-1)). In no case shall the pneumatic test pressure exceed one and one... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be...

  1. A quantitative method for the evaluation of three-dimensional structure of temporal bone pneumatization.

    PubMed

    Hill, Cheryl A; Richtsmeier, Joan T

    2008-10-01

    Temporal bone pneumatization has been included in lists of characters used in phylogenetic analyses of human evolution. While studies suggest that the extent of pneumatization has decreased over the course of human evolution, little is known about the processes underlying these changes or their significance. In short, reasons for the observed reduction and the potential reorganization within pneumatized spaces are unknown. Technological limitations have limited previous analyses of pneumatization in extant and fossil species to qualitative observations of the extent of temporal bone pneumatization. In this paper, we introduce a novel application of quantitative methods developed for the study of trabecular bone to the analysis of pneumatized spaces of the temporal bone. This method utilizes high-resolution X-ray computed tomography (HRXCT) images and quantitative software to estimate three-dimensional parameters (bone volume fractions, anisotropy, and trabecular thickness) of bone structure within defined units of pneumatized spaces. We apply this approach in an analysis of temporal bones of diverse but related primate species, Gorilla gorilla, Pan troglodytes, Homo sapiens, and Papio hamadryas anubis, to illustrate the potential of these methods. In demonstrating the utility of these methods, we show that there are interspecific differences in the bone structure of pneumatized spaces, perhaps reflecting changes in the localized growth dynamics, location of muscle attachments, encephalization, or basicranial flexion. PMID:18715622

  2. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... intended function under any normal system operating temperature or pressure, and (c) Means to indicate to... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection...

  3. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... car tires to meet safety criteria similar to those for new pneumatic passenger car tires....

  4. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be accomplished... allowable working pressure of the vessel to permit examination. (e) Pressure vessels pneumatically tested... testing of welded pressure vessels shall be permitted only for those units which are so designed...

  5. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ASME Boiler and Pressure Vessel Code. (d) The pneumatic test of pressure vessels shall be accomplished... allowable working pressure of the vessel to permit examination. (e) Pressure vessels pneumatically tested... testing of welded pressure vessels shall be permitted only for those units which are so designed...

  6. Intracranial volume in craniosynostotic rabbits.

    PubMed

    Mooney, M P; Burrows, A M; Wigginton, W; Singhal, V K; Losken, H W; Smith, T D; Dechant, J; Towbin, A; Cooper, G M; Towbin, R; Siegel, M I

    1998-05-01

    Although craniosynostosis alters brain growth direction resulting in compensatory changes in the neurocranium, it has been suggested that such compensations occur with little reduction in intracranial volume (ICV). This hypothesis was tested in a rabbit model with nonsyndromic, familial coronal suture synostosis. Cross-sectional three-dimensional computed tomographic head scans were obtained from 79 rabbits (25 normal, 28 with delayed-onset synostosis, and 26 with early-onset synostosis) at 25, 42, and 126 days of age. Intracranial contents were reconstructed and indirect ICV was calculated. Results revealed that by 25 days of age the intracranial contents from early-onset synostosed rabbit skulls showed rostral (anterior) constrictions and a "beaten copper" morphology in the parietal and temporal regions compared with the other two groups. These deformities increased in severity with age. Quantitatively, ICV was significantly reduced (P < 0.05) by 7% in rabbits with early-onset synostosis compared with both control rabbits and rabbits with delayed-onset synostosis at 25 days of age. By 126 days of age, ICV in rabbits with synostosis was significantly reduced (p < 0.05) by 11% in early-onset synostosis and by 8% in delayed-onset synostosis compared with normal rabbits. Results suggest that in rabbits with uncorrected craniosynostosis, compensatory changes in the neurocranium were not adequate to allow normal expansion of the neurocapsular matrix. Further research is needed to determine if ICV reduction is correlated with cerebral atrophy or cerebral spinal fluid (i.e., ventricular or subarachnoid) space compression in this model. PMID:9693554

  7. Frictional properties of lubrication greases with the addition of nickel nanoparticles in pneumatic cylinder

    NASA Astrophysics Data System (ADS)

    Chang, Ho; Lan, Chou-Wei; Guo, Jia-Bin

    2011-12-01

    This paper studies the influence of addition of 100 nm diameter nickel nano-particles on the friction properties of synthetic grease (Li base, VG100) in pneumatic cylinder. The friction force test of pneumatic cylinder equipment measures the frictional force between seal and cylinder bore in pneumatic cylinders. The lubricants with addition of nickel nano-particles were used for lubricating the contact interface between seal and cylinder bore. The friction force test equipment employ a load cell force sensor to measure the friction force between seals and cylinder bores. Results obtained from experimental tests are compared to determine the friction force between seals and cylinder bore in pneumatic cylinders. The study leads to the conclusion that the addition of nickel nano-particles to synthetic grease results in a decrease in friction force between seals and cylinder bores in pneumatic cylinder. This tribological behavior is closely related to the deposition of nano-particles on the rubbing surfaces

  8. The pneumatization patterns of the roof of the parapharyngeal space in CBCT

    PubMed Central

    Andrei, Felicia; Motoc, Andrei Gheorghe Marius; Jianu, Adelina Maria; Rusu, Mugurel Constantin; Loreto, Carla

    2012-01-01

    Introduction The rhinopharynx and the parapharyngeal space (PPS) are complex anatomical territories located beneath the skull base. Thorough knowledge of the complex anatomy of the PPS is essential in treatment of pathologies such as parapharyngeal abscesses. The roof of the PPS is overlooked in anatomy. It was hypothesized that the pneumatization pattern of the PPS roof is individually variable, as determined by the variable pneumatization patterns of the sphenoid and temporal bones. The study was aimed at assessing the anatomy of the PPS roof in CBCT. Methods The present study was performed retrospectively on a group of 35 subjects (37.1% males) evaluated by CBCT for various dental procedures. Results The mean age of the group was 37.9 (SD: 14.2, range: 18 to 61). The major bony landmarks of the PPS roof were: the petrous apex with the carotid canal, the jugular foramen, the foramen lacerum, the sphenopetrosal fissure or suture, and the root of the pterygoid process. Variable patterns of pneumatization were determined by the petrous apex air cells and the pterygoalar recess of the sphenoidal sinus. As related to the individually pattern of pneumatization, the following types of the PPS roof were defined: (i) type 1 – not pneumatized PPS roof; (ii) type 2 – sphenoidal but not petrosal pneumatization of the PPS roof; (iii) type 3 – petrosal but not sphenoidal pneumatization of the PPS roof; (iv) type 4 – sphenoidal and petrosal pneumatizations of the PPS roof. Discussion Although on the left side the degree of pneumatization was higher than on the right side, no statistical differences were recorded (p > 0.05). The pattern of pneumatizations in the PPS roof should be assessed when PPS involvement in otitis or sinusitis is considered. PMID:24432276

  9. Energy spectra of the pneumatically positioned neutron sources at LLNL's Hazards control standards and calibration facility

    SciTech Connect

    Thorngate, J.H.

    1987-06-15

    The Hazards Control Department of Lawrence Livermore National Laboratory maintains a Standards and Calibration Laboratory that includes three neutron sources (two /sup 252/Cf and one /sup 238/PuBe that can be positioned pneumatically for irradiations. Ten moderators exist to modify the neutron energy spectra produced by these sources. The thicknesses and materials of these moderators are: 25-cm water; 5-, 10-, 15-, and 25-cm heavy water; 20-cm aluminum; and 2-, 5-, 10-, and 15-cm polyethylene. We used a multisphere spectrometer to measure the neutron spectra at 2 m from both the PuBe source and the smaller Cf source, with the sources bare, and in all of the moderators. These data were reduced in 25 energy groups ranging from 0.25 eV to 16 MeV. Except for the 15-m polyethylene moderator, we also made measurements using a liquid-scintillator fast-neutron spectrometer. These data were reduced in 0.1-MeV increments from 0.5 to 12.5 MeV. Spectra from the measurements and from independent calculations are presented in tabular and graphic form. Dosimetric values, calculated from both the measured and calculated spectra, are also presented.

  10. Performance analysis and experiment validation of a pneumatic vibration isolator

    NASA Astrophysics Data System (ADS)

    Yang, Yuanyuan; Tan, Jiubin; Wang, Lei; Zhou, Tong

    2015-02-01

    A performance analysis and experiment validation of a pneumatic vibration isolator (PVI) that applied in the wafer stage of lithography is proposed in this work. The wafer stage of lithography is a dual-stage actuator system, including a long-stroke stage (LS) and a short-stroke stage (SS). In order to achieve the nanometer level positioning the isolator is designed to reduce the transmission of LS excitations to SS. In addition, considering the SS with six degrees of freedom and required to keep a strict constant temperature environment, the isolator need to have two functions, including the decoupling for vertical to horizontal and gravity compensation. In this isolator, a biaxial hinge was designed to decouple vertical rotation freedom, and a gas bearing was designed to decouple horizontal motion. The stiffness and damping of the pneumatic vibration isolator were analyzed. Besides, an analysis of the natural frequency and vibration transmissibility of the isolator is presented. In the end, the results show that vibration transmission is reduced significantly by the isolator and natural frequency can be lower than 0.6 Hz. This means that experimental results accord with the prediction model.

  11. Empirical modeling of dynamic behaviors of pneumatic artificial muscle actuators.

    PubMed

    Wickramatunge, Kanchana Crishan; Leephakpreeda, Thananchai

    2013-11-01

    Pneumatic Artificial Muscle (PAM) actuators yield muscle-like mechanical actuation with high force to weight ratio, soft and flexible structure, and adaptable compliance for rehabilitation and prosthetic appliances to the disabled as well as humanoid robots or machines. The present study is to develop empirical models of the PAM actuators, that is, a PAM coupled with pneumatic control valves, in order to describe their dynamic behaviors for practical control design and usage. Empirical modeling is an efficient approach to computer-based modeling with observations of real behaviors. Different characteristics of dynamic behaviors of each PAM actuator are due not only to the structures of the PAM actuators themselves, but also to the variations of their material properties in manufacturing processes. To overcome the difficulties, the proposed empirical models are experimentally derived from real physical behaviors of the PAM actuators, which are being implemented. In case studies, the simulated results with good agreement to experimental results, show that the proposed methodology can be applied to describe the dynamic behaviors of the real PAM actuators. PMID:23871151

  12. Development of an Air Pneumatic Suspension System for Transtibial Prostheses

    PubMed Central

    Pirouzi, Gholamhossein; Osman, Noor Azuan Abu; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Wan Abas, Wan A. B.

    2014-01-01

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded. PMID:25207872

  13. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-01

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices. PMID:24145429

  14. Pneumatic oscillator circuits for timing and control of integrated microfluidics

    PubMed Central

    Duncan, Philip N.; Nguyen, Transon V.; Hui, Elliot E.

    2013-01-01

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices. PMID:24145429

  15. Prognostics for Ground Support Systems: Case Study on Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Goebel, Kai

    2011-01-01

    Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.

  16. The cottontail rabbits of Virginia

    USGS Publications Warehouse

    Llewellyn, L.M.; Handley, C.O.

    1945-01-01

    Five races of cottontail rabbits belonging to three species occur in Virginia. One of them, the Mearns cottontail (Sylvilagus floridanus mearnsi), is reported here for the first time. It occurs in six southwestern counties of the state, while the eastern cottontail (S. f. mallurus) occurs in the remainder of the state with the exception of Smith and Fishermans islands off the eastern coast of Cape Charles, where it is replaced by Hitchens cottontail (S. f. hitchensi). The New England cottontail (S. transitionalis) is found on the higher mountain peaks, above 3000 feet, and the swamp rabbit (S. palustris) occurs in the Dismal Swamp region of southeastern Virginia.....The height of the breeding season for the eastern cottontail in Virginia is March and April, but breeding continues through the entire year except in December and January. The average litter size based on embryo counts was 4.7. The sex ratio of 234 specimens from all parts of the state, taken mostly in the December to February period, was 53 males to 47 females. That of a group of 145 rabbits live-trapped at Blacksburg during February and Marchwas 58 males to 42 females. The figures show that males are more active than females during the winter months, and therefore are more easily taken then....In transplanting cottontails from one section of the state to another, it is recommended that only cottontails of the same race as those originally present in the region being restocked be released there....Tularemia is not a common disease among rabbits in Virginia, but the rabbit ticks are often carriers of the disease and may transmit it to rabbits. Rabbit ticks are also found to be carriers of Rocky Mountain fever and American Q. fever. After the ticks drop off the rabbits to hibernate in the ground, which is likely to occur during mid-winter in Virginia, there is relatively little danger of humans contracting tularemia by contact with rabbits. Present laws in Virginia which prohibit rabbit hunting until the

  17. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved. PMID:26726680

  18. Induction and prevention of virus-associated malignant lymphoma by serial transmission of EBV-related virus from cynomolgus by blood transfusion in rabbits.

    PubMed

    Koirala, Tirtha Raj; Hayashi, Kazuhiko; Jin, Zaishun; Onoda, Sachiyo; Tanaka, Takehiro; Oda, Wakako; Ichimura, Koichi; Ohara, Nobuya; Oka, Takashi; Yamada, Masao; Yoshino, Tadashi

    2004-04-01

    Epstein-Barr virus (EBV)-related herpesvirus (Si-IIA-EBV) was serially transmitted for 3 passages from rabbit to rabbit of the opposite sex by blood transfusion, which subsequently induced virus-associated rabbit lymphomas. The virus could be transmitted by transfusion with 15-20 ml of whole blood (7/7) or irradiated blood (1/6) from the EBV-related virus-infected rabbits, but there was no transmission with transfusion of cell-free plasma (0/6) from the infected rabbits. Passive anti-EBV-VCA IgG (x 20 approximately x 10) titers decreased during the first 1-2 weeks in the transfused rabbits. The virus-transmitted rabbits showed a gradual increase in antibody titers ranging from peak titers of x 640 to x 2560 after 3 weeks of transfusion. The recipient origin of malignant lymphoma that developed in the first rabbit transfused by infected blood was confirmed by chromosomal analysis. This rabbit model thus shows that EBV-related herpesvirus is serially transmissible by blood transfusion and that transmission can not be completely prevented by irradiation of blood, but removal of blood cells is the best way to prevent transmission of EBV-related virus. Therefore, this animal model provides a convenient in vivo system for studies of the prevention and therapy of transfusion-related transmission of EBV and EBV-associated lymphoproliferative diseases in immunocompromised human beings. PMID:15255507

  19. Rabbit model of rotavirus infection.

    PubMed Central

    Conner, M E; Estes, M K; Graham, D Y

    1988-01-01

    A new small animal model was developed to study parameters of rotavirus infections, including the active immune response. Seronegative New Zealand White rabbits (neonatal to 4 months old) were inoculated orally with cultivatable rabbit rotavirus strains Ala, C11, and R2 and with the heterologous simian strain SA11. The course of infection was evaluated by clinical findings, virus isolation (plaque assay and enzyme-linked immunosorbent assay), and serologic response. All four strains of virus were capable of infecting rabbits as determined by isolation of infectious virus from intestinal contents or fecal samples, by seroconversion, or by a combination of these methods. The responses differed depending on the virus strain used for inoculation. Rabbits remained susceptible to primary infection to at least 16 weeks of age (upper limit examined). Virus excretion in intestinal contents was detected from 6 h to 7 days postinoculation. RNA electropherotypes of inocula and viruses isolated from rabbits were the same in all samples tested. Transmission of Ala virus and R2 virus but not SA11 virus from inoculated animals to uninoculated controls also occurred. In a challenge experiment with Ala virus, 74- and 90-day-old rabbits were rechallenged with Ala 5 weeks after a primary infection with Ala. Virus was excreted in feces from 2 to 8 days after the primary infection but was not excreted after challenge. These results indicate that the rabbit provides an ideal model to investigate both the primary and secondary active immune responses to rotavirus infections and to evaluate candidate vaccines. Images PMID:2833612

  20. Irradiation effect of polarization direction and intensity of semiconductor laser on injured peripheral nerve

    NASA Astrophysics Data System (ADS)

    Guo-Xin, Xiong; Lei-lei, Xiong

    2016-08-01

    To investigate the irradiation effect of polarization direction and the intensity of a semiconductor laser on the injured peripheral nerve in rabbits, the model of the injured common peroneal nerve was established, the L5,6 spinal segments of the rabbits were irradiated, a uniform rotating polarizer was placed at the laser output which made the polarization direction and intensity of the output laser change according to the 80 Hz cosine law. The experimental results show that irradiating the spinal segment of injured nerves in rabbits with this changeable semiconductor laser can significantly promote the regeneration of injured peripheral nerves and the function recovery.

  1. The qualitative assessment of pneumatic actuators operation in terms of vibration criteria

    NASA Astrophysics Data System (ADS)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.

  2. The role of particle collisions in pneumatic transport

    NASA Technical Reports Server (NTRS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-01-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  3. Preliminary measurements on heat balance in pneumatic tires

    NASA Technical Reports Server (NTRS)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  4. Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels

    NASA Astrophysics Data System (ADS)

    Wang, Chih-Hao; Lee, Gwo-Bin

    2006-02-01

    This study presents a novel pneumatic micropump featuring a serpentine-shape (S-shape) microchannel. Fluid is driven through the device by the hydrodynamic pressure generated by the peristaltic action of membranes located at the intersections of the fluidic microchannel and the S-shape microchannel. The pneumatic micropump is fabricated in PDMS (polydimethylsiloxane) using MEMS (micro-electro-mechanical-systems)-based techniques. The micropump provides an improved pumping rate and is controlled using a single electromagnetic valve (EMV) switch. The experimental results reveal that the pumping rate can be increased by increasing the operational frequency of the EMV, the pressure of the externally supplied compressed air or the number of membranes. As the compressed air travels along the S-shape microchannel, it causes the membranes to deflect. The time-phased deflection of successive membranes along the microchannel length generates a peristaltic effect which drives the fluid along the microfluidic channel. The maximum attainable pumping rate is influenced by the time interval between the deflections of adjacent membranes, and is therefore affected by the geometric characteristics of the serpentine microchannel. The back pressure of the serpentine-shape micropump is measured at a fixed peak frequency to prove its ability to overcome the fluidic resistance. The optimum operating conditions and geometric parameters of the micropump are verified experimentally. It is found that the maximum pumping rate is 7.43 µl min-1 and is provided by a micropump with seven membranes actuated by 20 psi air pressure and 9 Hz operational frequency. The preliminary results of the current paper were presented at the 2005 IEEE International Conference on Robotics and Biomimetics (IEEE ROBIO 2005), Hong Kong SAR, 29 June-03 July 2005.

  5. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  6. Teratology studies in the rabbit.

    PubMed

    Allais, Linda; Reynaud, Lucie

    2013-01-01

    The rabbit is generally the non-rodent species or second species after the rat recommended by the regulatory authorities and is part of the package of regulatory reproductive studies for the detection of potential embryotoxic and/or teratogenic effects of pharmaceuticals, chemicals, food additives, and other compounds, including vaccines (see Chapters 1-7).Its availability, practicality in housing and in mating as well as its large size makes the rabbit the preferred choice as a non-rodent species. The study protocols are essentially similar to those established for the rat (Chapter 9), with some particularities. The study designs are well defined in guidelines and are relatively standardized between testing laboratories across the world.As for the rat, large litter sizes and extensive background data in the rabbit are valuable criteria for an optimal assessment of in utero development of the embryo or fetus and for the detection of potential external or internal fetal malformations. PMID:23138902

  7. Differential Fault Analysis of Rabbit

    NASA Astrophysics Data System (ADS)

    Kircanski, Aleksandar; Youssef, Amr M.

    Rabbit is a high speed scalable stream cipher with 128-bit key and a 64-bit initialization vector. It has passed all three stages of the ECRYPT stream cipher project and is a member of eSTREAM software portfolio. In this paper, we present a practical fault analysis attack on Rabbit. The fault model in which we analyze the cipher is the one in which the attacker is assumed to be able to fault a random bit of the internal state of the cipher but cannot control the exact location of injected faults. Our attack requires around 128 - 256 faults, precomputed table of size 241.6 bytes and recovers the complete internal state of Rabbit in about 238 steps.

  8. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  9. European Rabbits as Reservoir for Coxiella burnetii

    PubMed Central

    González-Barrio, David; Maio, Elisa; Vieira-Pinto, Madalena

    2015-01-01

    We studied the role of European rabbits (Oryctolagus cuniculus) as a reservoir for Coxiella burnetii in the Iberian region. High individual and population seroprevalences observed in wild and farmed rabbits, evidence of systemic infections, and vaginal shedding support the reservoir role of the European rabbit for C. burnetii. PMID:25988670

  10. Costs and benefits of pneumatic collection in three specific New York City cases

    SciTech Connect

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-15

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of

  11. Costs and benefits of pneumatic collection in three specific New York City cases.

    PubMed

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-01

    Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more

  12. Osteoblastic Osteosarcoma in a Rabbit

    PubMed Central

    Ishikawa, Megumi; Kondo, Hirotaka; Onuma, Mamoru; Shibuya, Hisashi; Sato, Tsuneo

    2012-01-01

    An osteosarcoma developed in the tarsal joint region involving the distal tibia of a domestic rabbit (Oryctolagus cuniculus). Micrometastases were present in the lungs. Histologically the tumor was composed of ovoid to short-spindle cells with abundant giant cells, producing irregular islands of osteoids. The tumor cells were immunopositive with antiosteocalcin monoclonal antibody, consistent with their derivation from osteoblasts. According to review of 10 published cases, productive osteoblasic osteosarcoma is the most common bone tumor in rabbits, with half of all cases developing in the skull or facial bones. PMID:22546918

  13. Experimental infection of young rabbits with a rabbit enteric coronavirus.

    PubMed Central

    Descôteaux, J P; Lussier, G

    1990-01-01

    The clinical signs and lesions caused by the rabbit enteric coronavirus (RECV) were studied in young rabbits orally inoculated with a suspension containing RECV particles. The inoculated animals were observed daily for evidence of diarrhea. Fecal samples and specimens from the small intestine and from the gut associated lymphoid tissue (GALT) were collected from 2 h to 29 days postinoculation (PI) and processed for immune electron microscopy (IEM) and light microscopy. Coronavirus particles were detected in the cecal contents of most inoculated animals from 6 h to 29 days PI. Lesions were first observed 6 h PI and were characterized by a loss of the brush border of mature enterocytes located at the tips of intestinal villi and by necrosis of these cells. At 48 h PI, short intestinal villi and hypertrophic crypts were noted. In the GALT, complete necrosis of the M cells as well as necrosis of the enterocytes lining the villi above the lymphoid follicules with hypertrophy of the corresponding crypts were observed in all the animals. Five inoculated rabbits had diarrhea three days PI. The presence of RECV particles in the feces of the sick animals and the microscopic lesions observed in the small intestine suggested that the virus was responsible for the clinical signs. A few inoculated rabbits remained free of diarrhea. Fecal material collected at postmortem examination contained RECV particles. The results suggest that the virus could also produce a subclinical infection. Images Fig. 1. Fig. 2. Fig. 3. Fig. 4. PMID:2174299

  14. A method of transmissibility design for dual-chamber pneumatic vibration isolator

    NASA Astrophysics Data System (ADS)

    Lee, Jeung-Hoon; Kim, Kwang-Joon

    2009-06-01

    Dual-chamber pneumatic vibration isolators have a wide range of applications for vibration isolation of vibration-sensitive equipment. Recent advances in precision machine tools and instruments such as medical devices and those related to nano-technology require better isolation performance, which can be efficiently achieved by precise modeling- and design- of the isolation system. This paper discusses an efficient transmissibility design method of a pneumatic vibration isolator wherein a complex stiffness model of a dual-chamber pneumatic spring developed in our previous study is employed. Three design parameters, the volume ratio between the two pneumatic chambers, the geometry of the capillary tube connecting the two pneumatic chambers, and, finally, the stiffness of the diaphragm employed for prevention of air leakage, were found to be important factors in transmissibility design. Based on a design technique that maximizes damping of the dual-chamber pneumatic spring, trade-offs among the resonance frequency of transmissibility, peak transmissibility, and transmissibility in high frequency range were found, which were not ever stated in previous researches. Furthermore, this paper discusses the negative role of the diaphragm in transmissibility design. The design method proposed in this paper is illustrated through experimental measurements.

  15. Pneumatic motor powered Thrust Vector Control (TVC) for liquid propelled launch vehicles

    NASA Astrophysics Data System (ADS)

    Malone, Mark C.; Evans, P. S.

    1992-02-01

    Recent studies performed for the Titan 4 launch vehicle indicate significant potential advantages in replacing the current stage 1 and 2 recirculating hydraulic TVC (thrust vector control) system with a PMA (pneumatic mechanical actuation) system. Some of the advantages of a PMA system over the recirculating hydraulic system include reduced part count and weight, reduced maintenance and life-cycle cost, and improved mission reliability. PMA technology, used in aircraft applications since the 1960s, is well suited in launch vehicle TVC applications where an existing pneumatic pressure source is available. A typical pneumatic motor TVC consists of a pneumatic power source, a dual rotor pneumatic motor, a gear box, a ball screw actuator, and the associated closed-loop servo-control elements. One key issue with implementing this mechanical approach is designing a TVC system to withstand large load transient disturbances during liquid engine starting. Hydraulic actuator transient loads have exceeded 60,000 lb(sub f) for a 30,000 lb(sub f) stall design actuator during ground starts of the Titan 3B, Stage 1 engine. A PMA TVC system must also withstand these start transients without imparting excessive reaction loads to the engine nozzle and thrust structure. Work completed to date with Martin Marietta to examine pneumatic motor powered TVC options and technology benefits is presented. The load transient issue is discussed along with potential solutions and the associated trades. General background on PMA technology and experience base is also presented.

  16. Field and numerical determinations of pneumatic flow parameters of unsaturated fractured porous rocks on various scales

    NASA Astrophysics Data System (ADS)

    Guillon, S.; Vu, M. T.; Pili, E.; Adler, P. M.

    2013-05-01

    Air permeability is measured in the fractured crystalline rocks of the Roselend Natural Laboratory (France). Single-hole pneumatic injection tests as well as differential barometric pressure monitoring are conducted on scales ranging from 1 to 50 m, in both shallow and deep boreholes, as well as in an isolated 60 m3 chamber at 55 m depth. The field experiments are interpreted using numerical simulations in equivalent homogeneous porous media with their real 3-D geometry in order to estimate pneumatic parameters. For pneumatic injection tests, steady-state data first allow to estimate air permeability. Then, pressure recovery after a pneumatic injection test allows to estimate the air-filled porosity. Comparison between the various studied cases clarifies the influence of the boundary conditions on the accuracy of the often used 1-D estimate of air permeability. It also shows that permeabilities correlate slightly with fracture density. In the chamber, a 1 order-of-magnitude difference is found between the air permeabilities obtained from pneumatic injection tests and from differential barometric pressure monitoring. This discrepancy is interpreted as a scale effect resulting from the approximation of the heterogeneous fractured rock by a homogeneous numerical model. The difference between the rock volumes investigated by pneumatic injection tests and by differential barometric pressure monitoring may also play a role. No clear dependence of air permeability on saturation has been found so far.

  17. Development of Pneumatic Robot Hand and Construction of Master-Slave System

    NASA Astrophysics Data System (ADS)

    Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori

    Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.

  18. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetiuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials. PMID:26036066

  19. Development of myopia as a hazard for workers in pneumatic caissons

    PubMed Central

    Onoo, A; Kiyosawa, M; Takase, H; Mano, Y

    2002-01-01

    Background/aim: Pneumatic caisson engineering has been developed for large civil engineering constructions. Because of complaints of blurred vision by personnel working in pneumatic caissons, the development of myopia was suspected. The aim of this study was to determine the cause of the blurred vision and the mechanism underlying the changes. Methods: 12 caisson workers underwent a complete ophthalmological examination after completing up to 11 weeks of work (4 days/week) in a pneumatic caisson. Six months later, nine of the workers were examined again. Results: Nine subjects were myopic at the initial examination, and seven of these were considered to have developed the myopia after starting to work in the pneumatic caisson. Six months after completion of the work, the mean refractive change was significantly towards hyperopia. Conclusions: The blurred vision in pneumatic caisson workers was in all likelihood due to the development of myopia. The refractive shift towards hyperopia after completion of work in the pneumatic caisson supports this and demonstrates that the changes were temporary. The myopia is similar to the myopia seen in patients treated by hyperbaric oxygen. Careful monitoring of the refraction of caisson workers should be performed for industrial health control. PMID:12386088

  20. The Reliability and Maintainability Analysis of Pneumatic System of Rotary Drilling Machines

    NASA Astrophysics Data System (ADS)

    Rahimdel, Mohammad Javad; Hosienie, Seyed Hadi; Ataei, Mohammad; Khalokakaei, Reza

    2013-10-01

    In any blasthole drilling the bottom of the blasthole must be kept clean by evacuating drill cuttings or it flushing as soon as they appear to ensure efficient drilling. If it is not done well, a large quantity of energy will be consumed in regrinding with the consequent wear on drill bit and decrease penetration, apart from the risk of jamming. Therefore, research on reliability and probability of safe operation of pneumatic system of drilling machines is of prime importance to ensure safe drilling operations. In this paper, reliability of this system was modeled and analyzed. To doing this research, drilling machines in Sarcheshmeh Copper Mine in Iran have been selected for data collection and analysis. After reliability modeling of pneumatic system, maintenance scheduling has been presented based on different reliability levels. There were four rotary drilling machines in this mine (named A, B, C and D). Results showed that after about 7 h drilling of machines A and B, and after 103 and 44 h drilling of machines C and D respectively, noticeably the reliability of pneumatic system reached to 80 %. As a result, machines C and D have more reliable pneumatic systems in comparison to machines A and B and checking and servicing of pneumatic system before these time was essential. Also, maintainability analysis showed that more failures of pneumatic system of machines A, B, C and D will be noticeably repaired at about 28, 34, 6 and 9 h.

  1. Reversible thermo-pneumatic valves on centrifugal microfluidic platforms.

    PubMed

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Kazemzadeh, Amin; Rothan, Hussin A; Yusof, Rohana; Madou, Marc

    2015-08-21

    Centrifugal microfluidic systems utilize a conventional spindle motor to automate parallel biochemical assays on a single microfluidic disk. The integration of complex, sequential microfluidic procedures on these platforms relies on robust valving techniques that allow for the precise control and manipulation of fluid flow. The ability of valves to consistently return to their former conditions after each actuation plays a significant role in the real-time manipulation of fluidic operations. In this paper, we introduce an active valving technique that operates based on the deflection of a latex film with the potential for real-time flow manipulation in a wide range of operational spinning speeds. The reversible thermo-pneumatic valve (RTPV) seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. The RTPV is a gas-impermeable valve composed of an air chamber enclosed by a latex membrane and a specially designed liquid transition chamber that enables the efficient usage of the applied thermal energy. Inputting thermo-pneumatic (TP) energy into the air chamber deflects the membrane into the liquid transition chamber against an inlet, sealing it and thus preventing fluid flow. From this point, a centrifugal pressure higher than the induced TP pressure in the air chamber reopens the fluid pathway. The behaviour of this newly introduced reversible valving system on a microfluidic disk is studied experimentally and theoretically over a range of rotational frequencies from 700 RPM to 2500 RPM. Furthermore, adding a physical component (e.g., a hemispherical rubber element) to induce initial flow resistance shifts the operational range of rotational frequencies of the RTPV to more than 6000 RPM. An analytical solution for the cooling of a heated RTPV on a spinning disk is also presented, which highlights the need for the future development of time-programmable RTPVs. Moreover, the reversibility and gas impermeability of the RTPV in the

  2. Pneumatic artificial muscle actuators for compliant robotic manipulators

    NASA Astrophysics Data System (ADS)

    Robinson, Ryan Michael

    Robotic systems are increasingly being utilized in applications that require interaction with humans. In order to enable safe physical human-robot interaction, light weight and compliant manipulation are desirable. These requirements are problematic for many conventional actuation systems, which are often heavy, and typically use high stiffness to achieve high performance, leading to large impact forces upon collision. However, pneumatic artificial muscles (PAMs) are actuators that can satisfy these safety requirements while offering power-to-weight ratios comparable to those of conventional actuators. PAMs are extremely lightweight actuators that produce force in response to pressurization. These muscles demonstrate natural compliance, but have a nonlinear force-contraction profile that complicates modeling and control. This body of research presents solutions to the challenges associated with the implementation of PAMs as actuators in robotic manipulators, particularly with regard to modeling, design, and control. An existing PAM force balance model was modified to incorporate elliptic end geometry and a hyper-elastic constitutive relationship, dramatically improving predictions of PAM behavior at high contraction. Utilizing this improved model, two proof-of-concept PAM-driven manipulators were designed and constructed; design features included parallel placement of actuators and a tendon-link joint design. Genetic algorithm search heuristics were employed to determine an optimal joint geometry; allowing a manipulator to achieve a desired torque profile while minimizing the required PAM pressure. Performance of the manipulators was evaluated in both simulation and experiment employing various linear and nonlinear control strategies. These included output feedback techniques, such as proportional-integral-derivative (PID) and fuzzy logic, a model-based control for computed torque, and more advanced controllers, such as sliding mode, adaptive sliding mode, and

  3. Pneumatic v electrokinetic lithotripsy in treatment of ureteral stones.

    PubMed

    Vorreuther, R; Klotz, T; Heidenreich, A; Nayal, W; Engelmann, U

    1998-06-01

    Recently, a new device (Combilith) for electrokinetic lithotripsy (EKL) has become available which is very similar to the well-known device for pneumatic (ballistic) lithotripsy (Swiss Lithoclast). The Lithoclast uses air pressure to push a projectile within the handpiece against the end of a metal probe, which is thereby accelerated and thrown like a jackhammer against the stone. In principle, the same stroking movement of a small metal probe is provided by EKL; the difference is that instead of a projectile, a magnetic core within the handpiece is accelerated by the electromagnetic principle. This paper compares the clinical efficacy and the features of the two devices. Testing the devices on a stone model, taking into account stone propulsion, the systems turned out to equally effective regarding stone disintegration. However, stone displacement was more pronounced with the Lithoclast applied on easily breaking stones. In a second experiment, an optoelectronic movement-measuring apparatus (Zimmer camera) was employed to measure the range and velocity of the movement of the probe tip without any contact. The linear acceleration velocity ranged from 5 to a maximum of 12.5 m/sec with both systems, but the maximum height of the stroke was 2.5 mm with the Lithoclast and 1 mm with EKL. After the initial break-up of soft stones, further impact of the probe tip against the stone resulted merely in propulsion; thus, the greater probe stroke height is the cause of the stone displacement. In a clinical trial, 22 ureteral stones were treated with the Lithoclast and 35 with the EKL. The two devices were equally effective in terms of stone disintegration and safety margin. Fixation using a Dormia basket was necessary in 12 cases (8 Lithoclast, 4 EKL). Although a difference in probe stroke height was noted when comparing pneumatic and electrokinetic lithotripsy, there were no clinically significant differences in the efficacy of stone fragmentation or stone-free rates. At the

  4. Acute Radiation Hypotension in the Rabbit: a Model for the Human Radiation Shock Syndrome.

    NASA Astrophysics Data System (ADS)

    Makale, Milan Theodore

    This study has shown that total body irradiation (TBI) of immature (40 to 100 day old) rabbits leads to an acute fall in mean arterial pressure (MAP) 30 to 90 minutes after exposure, which takes no more than about three minutes, and often results in pressures which are less than 50% of the lowest pre-exposure MAP. This is termed acute cardiovascular collapse (ACC). ACC is often accompanied by ECG T-wave elevation, a sharp rise in ear temperature, labored breathing, pupillary constriction, bladder emptying, and loss of abdominal muscle tone. About 73% of 40 to 100 day rabbits exhibit ACC; the others and most older rabbits display gradual pressure reductions (deliberate hypotension) which may be profound, and which may be accompanied by the same changes associated with ACC. ACC and deliberate hypotension occurred in rabbits cannulated in the dorsal aorta, and in non-operated animals. The decline in MAP for all 40 to 100 day cannulated rabbits (deliberate and ACC responders) is 55.4%. The experiments described below only involved 40 to 100 day cannulated TBI rabbits. Heart region irradiation resulted in an average MAP decline of 29.1%, with 1/15 rabbits showing ACC. Heart shielding during TBI reduced the decline in MAP to 19%, with 1/10 rabbits experiencing ACC. These results imply that the heart region, which includes the heart, part of the lungs, neural receptors, roots of the systemic vessels, and the blood, is a sensitive target. Bilateral vagotomy reduced the decline in MAP to 24.9%, and abolished ACC. Atropine (6 mg/kg) reduced the frequency of ACC to 26%, and the decline in MAP to 41.4%. In 11/13 rabbits the voltage generated by left vagal transmission rose after TBI. The vagi appear to participate in radiation hypotension. Heart shielding together with bilateral vagotomy reduced the decline in MAP to only 9.9%, with no ACC responders. The mean right ventricular pressure (MRVP) rose after TBI in 8/10 rabbits. In animals which displayed either ACC or steep

  5. Observations of ''granular jump'' in the pneumatic conveying system

    SciTech Connect

    Jaworski, Artur J.; Dyakowski, Tomasz

    2007-08-15

    This paper presents a preliminary study of a previously unreported phenomenon of the ''gas driven granular jump'', observed in the gas-solids flow within the pneumatic conveying system. From the phenomenological point of view, it resembles the already known processes such as hydraulic jumps in shallow water or granular jumps in granular flows in chutes or avalanches (although it seems most appropriate to explain it by analogy to a propagating granular bore). Clearly, unlike in classical phenomena of this type, the flow itself is driven by the aerodynamic forces related to the gas flow and the behaviour of the front of the ''jump'' is modified significantly by their presence. A series of high-speed camera visualisations are presented, which focus on this unusual behaviour of the flow on the border-line between cluster and stratified flow regimes in a horizontal pipe. Some similarities are drawn between the observed phenomenon and the broader class of problems exhibiting transition between super- and sub-critical flows. The fluid dynamical aspects and possible mechanisms behind the new phenomenon are discussed and the results obtained are compared quantitatively with simple theoretical models. (author)

  6. Controllable surface haptics via particle jamming and pneumatics.

    PubMed

    Stanley, Andrew A; Okamura, Allison M

    2015-01-01

    The combination of particle jamming and pneumatics allows the simultaneous control of shape and mechanical properties in a tactile display. A hollow silicone membrane is molded into an array of thin cells, each filled with coffee grounds such that adjusting the vacuum level in any individual cell rapidly switches it between flexible and rigid states. The array clamps over a pressure-regulated air chamber with internal mechanisms designed to pin the nodes between cells at any given height. Various sequences of cell vacuuming, node pinning, and chamber pressurization allow the surface to balloon into a variety of shapes. Experiments were performed to expand existing physical models of jamming at the inter-particle level to define the rheological characteristics of jammed systems from a macroscopic perspective, relevant to force-displacement interactions that would be experienced by human users. Force-displacement data show that a jammed cell in compression fits a Maxwell model and a cell deflected in the center while supported only at the edges fits a Zener model, each with stiffness and damping parameters that increase at higher levels of applied vacuum. This provides framework to tune and control the mechanical properties of a jamming haptic interface. PMID:25594980

  7. Precision pneumatic pressure measurement with diaphragm-based mechatronic devices

    NASA Astrophysics Data System (ADS)

    Karuppanan, Balasubramanian; Akin, Cellatoglu

    2010-01-01

    A clamped circular metallic diaphragm, with shallow spherical shell deformation, elongates spherically proportional to the pressure acting on it. By making use of the inflation characteristics and mechanical properties of the diaphragm, three types of pneumatic pressure sensor are proposed in this article. In the first type, an optical mirror is engraved on its outer surface in an optimal position falling midway between its vertex and circumference. A laser beam is made to incident on the mirror and it gets deflected to fall over a matrix of photocells; the excitation of a particular cell in the coordinates of the matrix determines the pressure acting on the diaphragm. In the second proposal, a weightless secondary coil of a transformer is fixed around the vertex of the diaphragm which would move around a stationary magnetic core. The excitation of the primary coil wound over the magnetic core causes a voltage to be picked up in the secondary coil which would depend upon the displacement of the vertex because of pressure. The third type of the transducer is a capacitance pickup arrangement wherein the pressure is converted into capacitance and it is sensed and displayed as pressure. Furthermore, as an extension of the work, the motion of the diaphragm is mechanically coupled to a stylus for producing hard copy of the pressure over a strip chart.

  8. Pneumatically-actuated artificial cilia array for biomimetic fluid propulsion.

    PubMed

    Gorissen, Benjamin; de Volder, Michaël; Reynaerts, Dominiek

    2015-11-21

    Arrays of beating cilia emerged in nature as one of the most efficient propulsion mechanisms at a small scale, and are omnipresent in microorganisms. Previous attempts at mimicking these systems have foundered against the complexity of fabricating small-scale cilia exhibiting complex beating motions. In this paper, we propose for the first time arrays of pneumatically-actuated artificial cilia that are able to address some of these issues. These artificial cilia arrays consist of six highly flexible silicone rubber actuators with a diameter of 1 mm and a length of 8 mm that can be actuated independently from each other. In an experimental setup, the effects of the driving frequency, phase difference and duty cycle on the net flow in a closed-loop channel have been studied. Net fluid speeds of up to 19 mm s(-1) have been measured. Further, it is possible to invert the flow direction by simply changing the driving frequency or by changing the duty cycle of the driving block pulse pressure wave without changing the bending direction of the cilia. Using PIV measurements, we corroborate for the first time existing mathematical models of cilia arrays to measurements on prototypes. PMID:26439855

  9. An electromagnetic microvalve for pneumatic control of microfluidic systems.

    PubMed

    Liu, Xuling; Li, Songjing

    2014-10-01

    An electromagnetic microvalve for pneumatic control of microfluidic devices has been designed, fabricated, and tested. The microvalve is composed of two parts: a miniature electromagnetic actuator and a valve body. The electromagnetic actuator consists mainly of a thin polydimethylsiloxane (PDMS)-based elastomer, which acts as the valve diaphragm. The diaphragm, used as a solid hydraulic medium, converts the large contact area of a valve core into a small contact area of valve head while maintaining a large stroking force. This microvalve remains closed because of a compressed mechanical spring force generated by the actuator. On the other hand, when a voltage is applied, the valve core moves up, relaxing the thin PDMS membrane, opening the microvalve. The fast open response (~17 ms) of the valve was achieved with a leak rate as low as 0.026 sccm at 200 KPa (N2) pressure. We tested the pertinent dynamic parameters such as flow rate in on/off mode, flow rate of duty cycles, and actuated frequencies in pulse width modulation (PWM) mode. Our method provides a simple, cheap, and small microvalve that avoids the bulky and expensive external pressure control solenoid manifold. This allows it to be easily integrated into portable and disposable devices. PMID:24742860

  10. Effectiveness of pneumatic reduction of ileocolic intussusception in children.

    PubMed

    Menor, F; Cortina, H; Marco, A; Olague, R

    1992-01-01

    A total of 158 consecutive therapeutic air enemas were performed upon 133 patients during a 2-year period. Perforation and/or an impairment of the general condition of the children were the only main contraindications for the reduction attempt (five patients). Successful reductions were achieved in 89% of cases with no complications. Operation was performed in all 17 cases of unsuccessful reduction: resection in four cases, easy manual reduction in nine, difficult manual reduction in two, and spontaneous reduction in two. There were 16 (12%) patients with one or more recurrent episodes. In 23 (16%) cases, following pneumatic reduction, a swollen ileocecal valve showing a multiple appearance was observed. This fact sometimes results in a differential diagnosis with incomplete reduction; in all these cases, small bowel aeration was always a sign of complete reduction. No significant difference was noted between a swollen ileocecal valve and patient age, duration of symptoms, presence of small bowel obstruction, and further recurrences. Air enema has improved our previous success obtained with hydrostatic reduction (79%), as well as being a simpler, cleaner, and faster technique for intussusception reduction in children. PMID:1426851

  11. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    PubMed

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  12. Design and validation of a MR-compatible pneumatic manipulandum.

    PubMed

    Suminski, Aaron J; Zimbelman, Janice L; Scheidt, Robert A

    2007-07-30

    The combination of functional MR imaging and novel robotic tools may provide unique opportunities to probe the neural systems underlying motor control and learning. Here, we describe the design and validation of a MR-compatible, 1 degree-of-freedom pneumatic manipulandum along with experiments demonstrating its safety and efficacy. We first validated the robot's ability to apply computer-controlled loads about the wrist, demonstrating that it possesses sufficient bandwidth to simulate torsional spring-like loads during point-to-point flexion movements. Next, we verified the MR-compatibility of the device by imaging a head phantom during robot operation. We observed no systematic differences in two measures of MRI signal quality (signal/noise and field homogeneity) when the robot was introduced into the scanner environment. Likewise, measurements of joint angle and actuator pressure were not adversely affected by scanning. Finally, we verified device efficacy by scanning 20 healthy human subjects performing rapid wrist flexions against a wide range of spring-like loads. We observed a linear relationship between joint torque at peak movement extent and perturbation magnitude, thus demonstrating the robot's ability to simulate spring-like loads in situ. fMRI revealed task-related activation in regions known to contribute to the control of movement including the left primary sensorimotor cortex and right cerebellum. PMID:17498811

  13. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    PubMed Central

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  14. Rapid Pneumatic Transport of Radioactive Samples - RaPToRS

    NASA Astrophysics Data System (ADS)

    Padalino, S.; Barrios, M.; Sangster, C.

    2005-10-01

    Some ICF neutron activation diagnostics require quick retrieval of the activated sample. Minimizing retrieval times is particularly important when the half-life of the activated material is on the order of the transport time or the degree of radioactivity is close to the background counting level. These restrictions exist in current experiments performed at the Laboratory for Laser Energetics, thus motivating the development of the RaPToRS system. The system has been designed to minimize transportation time while requiring no human intervention during transport or counting. These factors will be important if the system is to be used at the NIF where radiological hazards will be present during post activation. The sample carrier is pneumatically transported via a 4 inch ID PVC pipe to a remote location in excess of 100 meters from the activation site at a speed of approximately 7 m/s. It arrives at an end station where it is dismounted robotically from the carrier and removed from its hermetic package. The sample is then placed by the robot in a counting station. This system is currently being developed to measure back-to-back gamma rays produced by positron annihilation which were emitted by activated graphite. Funded in part by the U.S. DOE under sub contract with LLE at the University of Rochester.

  15. Variable recruitment in bundles of miniature pneumatic artificial muscles.

    PubMed

    DeLaHunt, Sylvie A; Pillsbury, Thomas E; Wereley, Norman M

    2016-01-01

    The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these standard manipulators can experience significant efficiency losses when operated outside their target performance ranges at low actuation pressures. This study considers the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle. Bundles of miniature PAMs are experimentally characterized, their actuation behavior is modeled, and the efficiency gains and losses associated with the application of a variable recruitment control strategy are assessed. This bio-inspired control strategy allows muscle bundles to operate the fewest miniature PAMs necessary to achieve a desired performance objective, improving the muscle bundle's operating efficiency over larger ranges of force generation and displacement. The study also highlights the need for improved PAM fabrication techniques to facilitate the production of identical miniature PAMs for inclusion in muscle bundles. PMID:27623216

  16. Characteristic analysis and experimental evaluation of artificial pneumatic cylinder

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Soo; Bae, Sang-Kyu; Choi, Kyung-Hyun

    2005-12-01

    The fluidic muscle cylinder consists of an air bellows tube, flanges and lock nuts. Its features are softness of material and motion, simplicity of structure, low production cost and high power efficiency. Recently, unlikely the pneumatic cylinder, the fluidic muscle cylinder without air leakage, stick slip, friction, and seal was developed as a new concept actuator. It has the characteristics such as light weight, low price, high response, durable design, long life, high power, high contraction, which is innovative product fulfilling RT(Robot Technology) which is one of the nation-leading next generation strategy technologies 6T as well as cleanness technology. The application fields of the fluidic muscle cylinder are so various like fatigue tester, brake, accelerator, high technology testing device such as driving simulator, precise position, velocity, intelligent servo actuator under special environment such as load controlling system, and intelligent robot. In this study, we carried out the finite element modeling and analysis about the main design variables such as contraction ration and force, diameter increment of fluidic muscle cylinder. On the basis of finite element analysis, the prototype of fluidic muscle cylinder was fabricated and tested. Finally, we compared the results between the test and the finite element analysis.

  17. Research on reliability test circuit of pneumatic pressure regulator

    NASA Astrophysics Data System (ADS)

    Ma, Jungong; Wang, Haitao; Oneyama, Naotake; Senoo, Mitsuru; Zhang, Huping

    2006-11-01

    In order to evaluate ISO/CD19973-4, some items had been tested, such as step response, valve opening, feasible opening frequency, air consumption, piping influence, cycle response and so on. The results show that Valve opening varies sensitively to the size of piping, solenoid valve and test chamber. The valve of regulator opens to some extent, closes immediately, and never reaches the full opening. If these circuit specifications are defined concretely and observed strictly, it is not impossible to obtain a certain required opening ratio and air consumption is very large. On the side, the compared tests based on the Japanese JIS test circuit having been carried out, the results show that, regardless of test circuit specifications, the valve of regulator always repeats full closing and full opening. The relief valve of the regulator operates too. At the same operating frequency, air consumption is one digit less than the one in ISO/CD 19973-4 circuit. In the end, improved JIS circuit was put forward as a reliability circuit of pneumatic pressure regulator.

  18. Rod-based Fabrication of Customizable Soft Robotic Pneumatic Gripper Devices for Delicate Tissue Manipulation.

    PubMed

    Low, Jin-Huat; Yeow, Chen-Hua

    2016-01-01

    Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage. PMID:27584722

  19. Late effects from particulate radiations in primate and rabbit tissues

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Bergtold, D. S.; Lee, A. C.; Pickering, J. E.

    1984-01-01

    In connection with studies regarding the hazards posed by ionizing radiations to man in space, the U.S. Air Force conducted an experiment about 20 years ago. In this experiment a large number of young rhesus monkeys was exposed to proton fluxes similar to those to be anticipated during solar flares. After irradiation, the animals were kept at the USAF School of Aerospace Medicine in Texas. The monkeys have been employed in investigations concerning aspects of late radiation damage. These investigations are discussed, taking into account the propagation of fibroblasts from irradiated monkeys. The results of the investigations are evaluated, giving attention also to experiments with white rabbits. It is found that, except in the case of major solar flares, when acute radiation damage could lead quickly to death, the hazards to astronauts from space radiations arise from such debilitating late effects as cataracts, damage to the central nervous system and benign tumors, and life-threatening neoplasia.

  20. Immunosuppression abrogates resistance of young rabbits to Rabbit Haemorrhagic Disease (RHD)

    PubMed Central

    2014-01-01

    Rabbit Haemorrhagic Disease (RHD) is caused by a calicivirus (RHDV) that kills 90% of infected adult European rabbits within 3 days. Remarkably, young rabbits are resistant to RHD. We induced immunosuppression in young rabbits by treatment with methylprednisolone acetate (MPA) and challenged the animals with RHDV by intramuscular injection. All of these young rabbits died within 3 days of infection due to fulminant hepatitis, presenting a large number of RHDV-positive dead or apoptotic hepatocytes, and a significant seric increase in cytokines, features that are similar to those of naïve adult rabbits infected by RHDV. We conclude that MPA-induced immunosuppression abrogates the resistance of young rabbits to RHD, indicating that there are differences in the innate immune system between young and adult rabbits that contribute to their distinct resistance/susceptibility to RHDV infection. PMID:24490832

  1. Ionophore antibiotic (narasin) poisoning in rabbits.

    PubMed

    Salles, M S; Lombardo de Barros, C S; Barros, S S

    1994-10-01

    Outbreaks of narasin poisoning in rabbits from several commercial rabbit-raising farms in the state of Parana, Brazil, are reported. Approximately 5,000/35,000 rabbits died after having consumed a pelleted ration to which poultry ration premix had been added. Clinical signs included apathy, anorexia, muscle weakness, impaired walking, diarrhea, respiratory distress, and opistothonus. Gross findings were not remarkable, but varying degrees of degeneration, necrosis and regeneration of skeletal muscles were consistent histopathological features in affected rabbits. Myocardial changes were mild or absent. Thirty ppm of narasin were detected in the ration fed the rabbits. The disease was experimentally reproduced by feeding the suspected ration and by administering narasin po to rabbits. PMID:7839570

  2. Single line reversing system capsular pneumatic freight pipelines

    SciTech Connect

    Weaver, P.B.

    1999-07-01

    In the 1800's the first Pneumatic Tube Systems sent a carrier vertically from one floor to another in a hospital using a foot-powered bellows. The carrier was returned to the starting point down the same tube using gravity. This was the first Single Line Reversing system. As the stations were moved apart horizontally the foot-powered bellows at both ends became ineffective and were replaced with a single blower or exhauster. The blower/exhauster ran continuously therefore a second line for returning carriers to the starting point, had to be installed - hence Twin Line systems. These systems were used for transporting mail, paperwork, medications, steel mill samples, parts, tools, medical lab samples, etc., in hospitals, stores and other businesses. Twin Line systems were very popular until about 1970 at which time installation labor and material costs became expensive and controls were becoming unnecessarily complicated and expensive. These reasons plus new technology forced the return to Single Line Reversing technology. Back in the 1800's three ``people transporting'' subways were built. A fourth system was built under the Pentagon in the 1950's or 1960's. It is difficult to find information on this one. All are Single Line Reversing systems. The difference between a Single Line Reversing and a Twin Line system is exactly as the names imply. The principle of the operation of these systems is covered herein. The physics for these two kinds of systems is the same. The Single Line Reversing system is technically more complex but capital and operating expense is far less costly. These costs are discussed herein.

  3. Enteropathogenic Escherichia coli Prevalence in Laboratory Rabbits

    PubMed Central

    Swennes, Alton G.; Buckley, Ellen M.; Madden, Carolyn M.; Byrd, Charles P.; Donocoff, Rachel S.; Rodriguez, Loretta; Parry, Nicola M. A.; Fox, James G.

    2013-01-01

    Rabbit-origin enteropathogenic E. coli (EPEC) causes substantial diarrhea-associated morbidity and has zoonotic potential. A culture-based survey was undertaken to ascertain its prevalence. EPEC was isolated from 6/141 (4.3%) commercially-acquired laboratory rabbits. Three of these did not have diarrhea or EPEC-typical intestinal lesions; they instead had background plasmacytic intestinal inflammation. Asymptomatically infected rabbits may function as EPEC reservoirs. PMID:23391439

  4. Lens hexokinase deactivation by near-UV irradiation.

    PubMed

    Tung, W H; Chylack, L T; Andley, U P

    1988-03-01

    Photodamage to lens hexokinase has been investigated by exposing the lenses of rat, rabbit and calf eyes to 300 nm irradiation. Hexokinase activity was diminished by 15.9% +/- 5.4 and 23.4% +/- 5.0 upon irradiation of the isolated rat lens for 1 and 2 hours respectively. Irradiation of the whole eye for 2 hours resulted in hexokinase deactivation of 13.6% +/- 5.8 and 19.2% +/- 6.2 for rat and rabbit lens homogenates and 55% +/- 7 for calf lens capsule plus epithelium. Enzyme deactivation was prevented when the isolated lens was irradiated with the vitreous attached. Glucose, catalase or ascorbate added to the medium prior to irradiation, each had a protective effect on hexokinase deactivation. The results are consistent with a mechanism in which photochemical generation of active species of oxygen, via the photosensitizing action of tryptophan photoproducts, plays a significant role in enzyme deactivation. PMID:3359812

  5. Analysis of pneumatic hammer in rectangular aerostatic thrust bearing with groove

    NASA Astrophysics Data System (ADS)

    Ma, Wei; Tan, Jiubin; Cui, Jiwen; Liu, Yongmeng

    2015-02-01

    The pneumatic hammer in rectangular aerostatic thrust bearings with groove is analyzed using perturbation theory. Routh stability criterion was used to evaluate the critical condition of pneumatic hammer in rectangular aerostatic thrust bearings with groove, and the influence of supply pressure, throttle area, groove area, and thickness of film on aerostatic thrust bearings. It was found through analysis that the change rate of stiffness and the volume ratio of aerostatic bearing could be used to analyze the pneumatic hammer in rectangular aerostatic thrust bearings with groove. At a certain film thickness, the stability of aerostatic bearings could be improved by reducing supply pressure, increasing throttle area and decreasing groove area to facilitate the design of a general aerostatic thrust bearing.

  6. Powered glove with electro-pneumatic actuation unit for the disabled

    NASA Astrophysics Data System (ADS)

    Kawakami, Kosuke; Kumano, Shinichi; Moromugi, Shunji; Ishimatsu, Takakazu

    2007-12-01

    Authors have been developing a powered glove for people suffering from paralysis on their fingers to support their daily activity. Small air cylinders are used as actuators for this glove. Pneumatically-driven system has high advantages in case soft actuation is preferable. However, there are some problems to be solved in the pneumatically-driven system if the system is supposed to be used in our daily life. Huge air compressor is needed and solenoid valves emit loud sound for example. These problems are hurdles to commercialize the powered glove. To solve these problems authors have developed a new actuation unit by integrating an electric cylinder and an air cylinder. This actuation unit has advantages of both the electric actuation and the pneumatic actuation. Its advanced grip control ability has demonstrated through several experiments. The experimental results are reported in this paper.

  7. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    NASA Technical Reports Server (NTRS)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  8. Development of prosthetic arm with pneumatic prosthetic hand and tendon-driven wrist.

    PubMed

    Takeda, Hiroyuki; Tsujiuchi, Nobutaka; Koizumi, Takayuki; Kan, Hiroto; Hirano, Masanori; Nakamura, Yoichiro

    2009-01-01

    Recently, various prosthetic arms have been developed, but few are both attractive and functional. Considering human coexistence, prosthetic arms must be both safe and flexible. In this research, we developed a novel prosthetic arm with a five-fingered prosthetic hand using our original pneumatic actuators and a slender tendon-driven wrist using a wire drive and two small motors. Because the prosthetic hand's driving source is comprised of small pneumatic actuators, the prosthetic hand is safe when it makes contact with people; it can also operate flexibly. In addition, the arm has a tendon-driven wrist to expand its motion space and to perform many operations. First, we explain the pneumatic hand's drive mechanism and its tendon-driven wrist. Next, we identify the characteristics of the hand and the wrist and construct a control system for this arm and verify its control performance. PMID:19964378

  9. Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for calculus in bladder diverticula

    PubMed Central

    GU, SI-PING; YOU, ZHI-YUAN; HUANG, YUNTENG; LU, YI-JIN; HE, CAOHUI; CAI, XIAO-DONG; ZHOU, XIAO-MING

    2013-01-01

    The aim of this study was to investigate the effectiveness of minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for treating calculus in bladder diverticula. Percutaneous cystostomy with ureteroscopic pneumatic lithotripsy was performed on six elderly male patients with calculi in bladder diverticula, who could not be treated with transurethral ureteroscopic lithotripsy. The stones were successfully removed from all patients, with no complications such as bladder perforation, rupture, urethritis or cystitis. The surgery time was 15–60 min, with an average time of 32 min. Postoperative ultrasound or X-ray examination showed no stone residues and the bladder stoma healed well. No recurrent stones were detected in the follow-up of 3–24 months (average, 16 months). Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy is a safe, efficient and easy treatment for calculus in bladder diverticula. This method provides a new clinical approach for lithotripsy and we suggest that it is worthy of wider use. PMID:23837044

  10. A magnetorheological fluid embedded pneumatic vibration isolator allowing independently adjustable stiffness and damping

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaocong; Jing, Xingjian; Cheng, Li

    2011-08-01

    A magnetorheological (MR) fluid embedded pneumatic vibration isolator (MrEPI) with hybrid and compact connection of pneumatic spring and MR damping elements is proposed in this study. The proposed MrEPI system allows independent nonlinear stiffness and damping control with considerable maneuverable ranges. Meanwhile, it allows convenient switching between different passive and active vibration control modes, thus providing more flexibility and versatility in applications. To demonstrate the advantageous dynamic performance of the MrEPI, a nonlinear non-dimensional dynamic model is developed with full consideration of the nonlinear elements involved. A systematic analysis is therefore conducted which can clearly reveal the influence on system output performance caused by each physically important parameter and provide a useful insight into the analysis and design of nonlinear vibration isolators with pneumatic and MR elements.

  11. Spectrophotometric determination of aqueous sulfide on a pneumatically enhanced centrifugal microfluidic platform.

    PubMed

    Kong, Matthew C R; Salin, Eric D

    2012-11-20

    A pneumatically enhanced centrifugal microfluidic platform was developed for rapid spectrophotometric determination of aqueous sulfide. This platform performs an automated analysis based on the reaction between hydrogen sulfide and N,N-dimethyl-p-phenylenediamine in the presence of iron(III) chloride to form Methylene Blue. The platform design minimizes the number of integrated valves required, compared to other centrifugal systems, significantly improving the ease of fabrication. The sequential analytical procedure and spectrophotometric analyses were performed directly on-disk, demonstrating significant advantages in portability and cost over conventional analytical methods. This method allows for rapid and precise determination of aqueous sulfide in the concentration range of 0.4-2.0 mg L(-1), which can be extended by a pneumatically induced, on-disk serial dilution to 6.0 mg L(-1). A detection limit of 0.4 mg L(-1) was calculated for this pneumatically enhanced method. PMID:23075273

  12. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    SciTech Connect

    Kim, Kyung-Rok; Kim, Kyung-Soo Kim, Soohyun

    2014-07-15

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  13. Automated system for removal and pneumatic transport of fly ash from electric precipitator hoppers

    SciTech Connect

    V.K. Konovalov; O.V. Yashkin; V.V. Ermakov

    2008-03-15

    A system for removal and pneumatic transport of fly ash is examined, in which air pulses act on batches (pistons) of ash formed in a duct. Studies are made of the effect of several physical parameters on the force required to displace a piston of ash and these serve as a basis for choosing a system for removal and pneumatic transport of ash simultaneously from several hoppers of an electric precipitator. This makes it possible to separate the ash particles according to size without introducing additional components. Formulas are given for calculating the structural and dynamic parameters of this system and measurements of indirect dynamic parameters are used to calculate the input-output characteristics of the system. In order to optimize the system, configurations for summing several ducts into a single transport duct for pneumatic ash transport are proposed. Some variants of dry ash utilization and the advantages of producing of size-separated particles are considered.

  14. Operation of a dilute-phase pneumatic transport system at the new waste calcining facility

    SciTech Connect

    Law, J.P.; Bodner, S.S.

    1990-03-15

    The New Waste Calcining Facility (NWCF) located at the Idaho Chemical Processing Plant (ICPP) converts radioactive liquid solutions to granular solids in fluidized-bed calcination process. these very erosive solids are dilute-phase pneumatically transported to stainless steel bins for interim storage. The entire NWCF pneumatic transport system is located in highly radioactive cells so the system must be very reliable and free from erosion failures. The NWCF pneumatic transport system uses blinded tees, blinded laterals, wear pads and a specially designed fines metering valve to control the erosion in the system. The NWCF has processed and transported to interim storage approximately 1,350 cubic meters of calcine since initial start-up in 1982. This paper presents the operating history including data on erosion rates measured at various locations at NWCF.

  15. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  16. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  17. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  18. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  19. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  20. 76 FR 31584 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Extension of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... Initiation of Antidumping and Countervailing Duty Administrative Reviews, 75 FR 66349 (October 28, 2010). The... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... new pneumatic off-the-road tires from the People's Republic of China (``PRC''). This review covers...

  1. 75 FR 32158 - New Pneumatic Off-the-Road Tires from the People's Republic of China: Extension of Preliminary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... Revocation in Part, 74 FR 54956 (October 26, 2009). The preliminary results of this review are currently due... International Trade Administration New Pneumatic Off-the-Road Tires from the People's Republic of China... pneumatic off-the-road tires (``OTR Tires'') from the People's Republic of China (``PRC''). This...

  2. 75 FR 32159 - Certain New Pneumatic Off-the-Road Tires from the People's Republic of China: Extension of Time...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... and Requests for Revocation in Part, 74 FR 54956 (October 26, 2009). This review covers one producer... International Trade Administration Certain New Pneumatic Off-the-Road Tires from the People's Republic of China... new pneumatic off-the-road tires from the People's Republic of China for the period December 17,...

  3. 75 FR 62504 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ..., 73 FR 40485 (July 15, 2008) (``Final Determination''), as amended by Certain New Pneumatic Off-the... Sales at Less than Fair Value and Antidumping Duty Order, 73 FR 51624 (September 4, 2008). Respondent... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  4. Vibration control of a pneumatic driven piezoelectric flexible manipulator using self-organizing map based multiple models

    NASA Astrophysics Data System (ADS)

    Zhao, Zhi-li; Qiu, Zhi-cheng; Zhang, Xian-min; Han, Jian-da

    2016-03-01

    A kind of hybrid pneumatic-piezoelectric flexible manipulator system has been presented in the paper. A hybrid driving scheme is achieved by combining of a pneumatic proportional valve based pneumatic drive and a piezoelectric actuator bonded to the flexible beam. The system dynamics models are obtained based on system identification approaches, using the established experimental system. For system identification of the flexible piezoelectric manipulator subsystem, parametric estimation methods are utilized. For the pneumatic driven system, a single global linear model is not accurate enough to describe its dynamics, due to the high nonlinearity of the pneumatic driven system. Therefore, a self-organizing map (SOM) based multi-model system identification approach is used to get multiple local linear models. Then, a SOM based multi-model inverse controller and a variable damping pole-placement controller are applied to the pneumatic drive and piezoelectric actuator, respectively. Experiments on pneumatic driven vibration control, piezoelectric vibration control and hybrid vibration control are conducted, utilized proportional and derivative (PD) control, SOM based multi-model inverse controller, and the variable damping pole-placement controller. Experimental results demonstrate that the investigated control algorithms can improve the vibration control performance of the pneumatic driven flexible piezoelectric manipulator system.

  5. Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines.

    PubMed

    Yang, Bo; Tan, U-Xuan; McMillan, Alan; Gullapalli, Rao; Desai, Jaydev P

    2011-12-01

    This paper presents the design and control of an MRI-compatible 1-DOF needle driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities such as CT or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during radio-frequency ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first order system with time delay, because its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of non-uniform friction in the device. Sliding mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging. PMID:22058649

  6. Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines

    PubMed Central

    Yang, Bo; Tan, U-Xuan; McMillan, Alan; Gullapalli, Rao; Desai, Jaydev P.

    2011-01-01

    This paper presents the design and control of an MRI-compatible 1-DOF needle driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities such as CT or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during radio-frequency ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first order system with time delay, because its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of non-uniform friction in the device. Sliding mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging. PMID:22058649

  7. Precision Position Control of Pneumatic Servo Table Embedded with Aerostatic Bearing

    NASA Astrophysics Data System (ADS)

    Tsai, Ming-Hung; Hsu, Tzu-Yung; Pai, Kei-Ren; Shih, Ming-Chang

    This paper treats the control of a pneumatic servo table combining the air cylinders and sliding guides embedded with aerostatic bearing. Since compressed air flows into the small gap between the bearing and the sliding guide, the cylinder floats around the air film and on the guide surface of the table. The friction forces of the pneumatic servo table are measured, and the relation of frictional force and speed is plotted. The hybrid self-tuning fuzzy controller with the velocity compensators and dead-zone are proposed in this paper. From the experimental results, in case of different position, the positioning accuracy can reach the 0.04μm.

  8. On-line automatic detection of wood pellets in pneumatically conveyed wood dust flow

    NASA Astrophysics Data System (ADS)

    Sun, Duo; Yan, Yong; Carter, Robert M.; Gao, Lingjun; Qian, Xiangchen; Lu, Gang

    2014-04-01

    This paper presents a piezoelectric transducer based system for on-line automatic detection of wood pellets in wood dust flow in pneumatic conveying pipelines. The piezoelectric transducer senses non-intrusively the collisions between wood pellets and the pipe wall. Wavelet-based denoising is adopted to eliminate environmental noise and recover the collision events. Then the wood pellets are identified by sliding a time window through the denoised signal with a suitable threshold. Experiments were carried out on a laboratory test rig and on an industrial pneumatic conveying pipeline to assess the effectiveness and operability of the system.

  9. Position control of an electro-pneumatic system based on PWM technique and FLC.

    PubMed

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. PMID:24485509

  10. Mathematical modeling of pneumatic char injection in a direct reduction rotary kiln

    SciTech Connect

    Ramakrishnan, V.; Sai, P.S.T.

    1999-10-01

    A one-dimensional steady-state mathematical model is proposed for direct reduction process in rotary kilns akin to the SL/RN process. The model takes into account pneumatic coal char injection from the discharge end of the kiln to supplement the heat availability. The model is based on material and energy conservation principles, and the empirical equations for kinetics and heat transfer are obtained from the literature. Predictions are carried out for both iron oxide reduction and ilmenite beneficiation processes. Improvement in the performance was predicted with pneumatic char injection.

  11. Late effects from particulate radiations in primate and rabbit tissues

    NASA Astrophysics Data System (ADS)

    Lett, J. T.; Cox, A. B.; Bergtold, D. S.; Lee, A. C.; Pickering, J. E.

    Optic tissues in groups of New Zealand white rabbits were irradiated locally at different stages throughout the median life span of the species with a single dose (9 Gy) of 425 MeV/amu Ne ions (LET∞~30 keV/μm) and then inspected routinely for the progression of radiation cataracts. The level of early cataracts was found to be highest in the youngest group of animals irradiated (8 weeks old) but both the onset of late cataracts and loss of vision occurred earlier when animals were irradiated during the second half of the median life span. This age response can have serious implications in terms of space radiation hazards to man. Rhesus monkeys that had been subjected to whole-body skin irradiation (2.8 and 5.6 Gy) by 32 MeV protons (range in tissue ~ 1 cm) some twenty years previously were analysed for radiation damage by the propagation of skin fibroblasts in primary cultures. Such propagation from skin biopsies in MEM-α medium (serial cultivation) or in supplemented Ham's F-10 medium (cultivation without dilution) revealed late damage in the stem (precursor) cells of the skins of the animals. The proton fluxes employed in this experiment are representative of those occurring in major solar flares.

  12. Pneumatic locking device for magnetic bearing reaction wheel

    NASA Astrophysics Data System (ADS)

    Privat, Michel; da Costa, Arlindo

    2003-09-01

    Due to the launch vibration environment, the use of locking device is necessary for large or heavy mechanisms. This remark is true in particular for the inertial actuators like magnetic bearing reaction wheels. These actuators have a rotor that is in magnetic levitation without any contact with the stator. Locking device is mandatory to maintain the rotor during the launch vibrations. To avoid contact between rotor and stator during the functional phase, the link created by the locking device must be completely released. This article presents a pneumatic locking device with pyrotechnical sub-systems that have been realised by "ALCATEL Space Industries" for the reaction wheels development in the frame of a CNES satellites family. The first paragraph presents the wheel functioning and briefly describes the Electro-mechanical components of the reaction wheel. The second paragraph describes a device based on a metallic bellows ring. A nitrogen pressure in the ring allows pushing the rotor against the stator. The rotor release is obtained by drilling the system tubing with a pyrotechnic valve. The third point describes the qualification tests and the resulting data. Some functional tests are made in warm and cold case with the locking device in order to improve some mechanical characteristics including the locking effort generated and the leakage rate. Launch vibrations and thermal tests have been realised and the good functioning of the mechanism is proven. At the end of these tests, the qualification has been pronounced. The device is now implemented within the reaction wheel. This equipment should flight in 2004. The next paragraph presents the works realised under CNES Research and Technology contract. The objectives were the characterisation of metallic bellows and some technological studies to improve the knowledge of the mechanical and functional characteristics of these elements. The first study was to create a Finite Element model of a bellow in order to

  13. Relief of vasospasm by intravascular ultraviolet irradiation

    NASA Astrophysics Data System (ADS)

    Nakai, Kanji; Morimoto, Yuji; Ito, Hirotaka; Kominami, Kimito; Matsuo, Hirotaka; Arai, Tsunenori; Kikuchi, Makoto

    1998-05-01

    We investigated the photovasorelaxation with intravascular transluminal irradiation using in vivo model. A 2.5 Fr. catheter was inserted in the femoral artery of a rabbit under anesthesia. A 400 micrometers diameter quartz fiber was inserted through the catheter. The catheter was withdrawn from the distal end to the proximal end of the exposed femoral artery without laser irradiation in order to observe the mechanical dilation by the procedure. The femoral artery lumen was irradiated by a Helium-Cadmium(He-Cd) laser (wavelength; 325 nm) with 8 mW through the fiber during 30 s. We carried out that the laser irradiation produced vasorelaxation (185% on the average) compared with mechanical vasodilation (150% on the average) with angiography. The results suggest that intravascular transluminal irradiation with low-power UV laser might be applicable to the relief of acute arterial vasospasm.

  14. Viral skin diseases of the rabbit.

    PubMed

    Meredith, Anna L

    2013-09-01

    This article describes the viral skin diseases affecting the domestic rabbit, the most important being myxomatosis. Transmission and pathogenesis, clinical signs, diagnosis, treatment, and control are described and the article will be of interest to veterinary practitioners who treat rabbits. Shope fibroma virus, Shope papilloma virus, and rabbitpox are also discussed. PMID:24018033

  15. Rabbit models for continuous curvilinear capsulorhexis instruction

    PubMed Central

    Ruggiero, Jason; Keller, Christopher; Porco, Travis; Naseri, Ayman; Sretavan, David W.

    2012-01-01

    PURPOSE To develop a rabbit model for continuous curvilinear capsulorhexis (CCC) instruction. SETTING University of California San Francisco, San Francisco, California, USA. DESIGN Experimental study. METHODS Isolated rabbit lenses were immersed in 2% to 8% paraformaldehyde (PFA) fixative from 15 minutes to 6 hours. Rabbit eyes were treated by substituting aqueous with 2% to 4% PFA for 30 minutes to 6 hours, followed by washes with a balanced salt solution. Treated lenses and eyes were held in purpose-designed holders using vacuum. A panel of 6 cataract surgeons with 5 to 15 years of experience performed CCC on treated lenses and eyes and responded to a questionnaire regarding the utility of these models for resident teaching using a 5-item Likert scale. RESULTS The expert panel found that rabbit lenses treated with increasing amounts of fixative simulated CCC on human lens capsules from the third to the seventh decade of life. The panel also found fixative-treated rabbit eyes to simulate some of the experience of CCC within the human anterior chamber but noted a shallower anterior chamber depth, variation in pupil size, and corneal clouding under some treatment conditions. CONCLUSIONS Experienced cataract surgeons who performed CCC on these rabbit models strongly agreed that isolated rabbit lenses treated with fixative provide a realistic simulation of CCC in human patients and that both models were useful tools for capsulorhexis instruction. Results indicate that rabbit lenses treated with 8% PFA for 15 minutes is a model with good fidelity for CCC training. PMID:22727296

  16. Muscle injury induced beneath and distal to a pneumatic tourniquet: A quantitative animal study of effects of tourniquet pressure and duration

    SciTech Connect

    Pedowitz, R.A.; Gershuni, D.H.; Schmidt, A.H.; Friden, J.; Rydevik, B.L.; Hargens, A.R. )

    1991-07-01

    Previous recommendations regarding the safe period of tourniquet hemostasis were based largely on studies of ischemia distal to the tourniquet. This study quantitatively analyzed skeletal muscle injury induced beneath and distal to a pneumatic tourniquet applied to the hindlimbs of rabbits for 1, 2, or 4 hours with a cuff inflation pressure of 125, 200, or 350 mm Hg. Technetium Tc 99m pyrophosphate incorporation after systemic injection (Tc 99 uptake) and correlative histology were used to evaluate tissue damage 2 days after tourniquet application. Compared with the contralateral control limbs, compression and ischemia induced statistically significant increases in Tc 99 uptake in the thigh and leg regions of all groups. Pyrophosphate incorporation was significantly greater in the thigh region than in the leg region after 2 hours of compression in the 200 and 350 mm Hg pressure groups and following 4 hours of compression in all pressure groups. Focal and regional fiber necrosis and degeneration were observed in thigh muscles after 2 hours of tourniquet compression. Two hours of continuous tourniquet application at clinically relevant cuff inflation pressures induced significant skeletal muscle necrosis beneath the tourniquet. Use of the lowest possible inflation pressure for a limited duration should minimize the degree of tissue injury caused by tourniquet application.

  17. Thermal cataract formation in rabbits

    SciTech Connect

    Kramar, P.; Harris, C.; Guy, A.W.

    1987-01-01

    Intraocularly circulating hot water was used to produce cataracts in nine eyes of seven rabbits by maintaining their retrolental temperatures between 43 degrees C and 45 degrees C. A rapid rate of heating (1.3 degrees C/min) plus a sharp temperature gradient across the eye may have been contributing factors in the consistent production of cataracts at these temperatures. Biomicroscopy and light microscopy showed lens changes similar to those associated with acute exposure to microwave radiation. These findings support the assumption that microwave cataractogenesis is due to the local production of elevated temperatures.

  18. Survival of rabid rabbits after intrathecal immunization.

    PubMed

    Kesdangsakonwut, Sawang; Sunden, Yuji; Aoshima, Keisuke; Iwaki, Yoshimi; Okumura, Masahiro; Sawa, Hirofumi; Umemura, Takashi

    2014-06-01

    Rabies is a fatal zoonotic disease for which no effective treatment measures are currently available. Rabies virus (RABV) has anti-apoptotic and anti-inflammatory properties that suppress nerve cell damage and inflammation in the CNS. These features imply that the elimination of RABV from the CNS by appropriate treatment could lead to complete recovery from rabies. Ten rabbits showing neuromuscular symptoms of rabies after subcutaneous (SC) immunization using commercially available vaccine containing inactivated whole RABV particles and subsequent fixed RABV (CVS strain) inoculation into hind limb muscles were allocated into three groups. Three rabbits received no further treatment (the SC group), three rabbits received three additional SC immunizations using the same vaccine, and four rabbits received three intrathecal (IT) immunizations, in which the vaccine was inoculated directly into the cerebrospinal fluid (the SC/IT group). An additional three naïve rabbits were inoculated intramuscularly with RABV and not vaccinated. The rabbits exhibited neuromuscular symptoms of rabies within 4-8 days post-inoculation (dpi) of RABV. All of the rabbits died within 8-12 dpi with the exception of one rabbit in the SC group and all four rabbits in SC/IT group, which recovered and started to respond to external stimuli at 11-18 dpi and survived until the end of the experimental period. RABV was eliminated from the CNS of the surviving rabbits. We report here a possible, although still incomplete, therapy for rabies using IT immunization. Our protocol may rescue the life of rabid patients and prompt the future development of novel therapies against rabies. PMID:24397792

  19. Survival of rabid rabbits after intrathecal immunization

    PubMed Central

    Kesdangsakonwut, Sawang; Sunden, Yuji; Aoshima, Keisuke; Iwaki, Yoshimi; Okumura, Masahiro; Sawa, Hirofumi; Umemura, Takashi

    2014-01-01

    Rabies is a fatal zoonotic disease for which no effective treatment measures are currently available. Rabies virus (RABV) has anti-apoptotic and anti-inflammatory properties that suppress nerve cell damage and inflammation in the CNS. These features imply that the elimination of RABV from the CNS by appropriate treatment could lead to complete recovery from rabies. Ten rabbits showing neuromuscular symptoms of rabies after subcutaneous (SC) immunization using commercially available vaccine containing inactivated whole RABV particles and subsequent fixed RABV (CVS strain) inoculation into hind limb muscles were allocated into three groups. Three rabbits received no further treatment (the SC group), three rabbits received three additional SC immunizations using the same vaccine, and four rabbits received three intrathecal (IT) immunizations, in which the vaccine was inoculated directly into the cerebrospinal fluid (the SC/IT group). An additional three naïve rabbits were inoculated intramuscularly with RABV and not vaccinated. The rabbits exhibited neuromuscular symptoms of rabies within 4–8 days post-inoculation (dpi) of RABV. All of the rabbits died within 8–12 dpi with the exception of one rabbit in the SC group and all four rabbits in SC/IT group, which recovered and started to respond to external stimuli at 11–18 dpi and survived until the end of the experimental period. RABV was eliminated from the CNS of the surviving rabbits. We report here a possible, although still incomplete, therapy for rabies using IT immunization. Our protocol may rescue the life of rabid patients and prompt the future development of novel therapies against rabies. PMID:24397792

  20. Late skin damage in rabbits and monkeys after exposure to particulate radiations

    NASA Astrophysics Data System (ADS)

    Bergtold, D. S.; Cox, A. B.; Lett, J. T.; Su, C. M.

    Skin biopsies were taken from the central regions of the ears of New Zealand white rabbits following localized exposure of one ear of each rabbit to 530 MeV/amu Ar or 365 MeV/amu Ne ions. The unirradiated ears served as controls. Biopsies were taken also from the chests and inner thighs of rhesus monkeys after whole-body exposure to 32 MeV protons and from unirradiated control animals. The linear energy transfers (LET∞'s) for the radiations were 90 +/- 5, 35 +/- 3, and ~1.2 keV/μm, respectively. In the rabbit studies, explants were removed with a 2 mm diameter dermal punch at post-irradiation times up to five years after exposure. Similar volumes of monkey tissue were taken from skin samples excised surgically 16-18 years following proton irradiation. Fibroblast cultures were initiated from the explants and were propagated in vitro until terminal senescence (cessation of cell division) occurred. Cultures from irradiated tissue exhibited decreases in doubling potential that were dependent on radiation dose and LET∞ and seemed to reflect damage to stem cell populations. The implications of these results for astronauts exposed to heavy ions and/or protons in space include possible manifestations of residual effects in the skin many years after exposure (e.g. unsatisfactory responses to trauma or surgery).

  1. ACCUTECH PNEUMATIC FRACTURING EXTRACTION AND HOT GAS INJECTION, PHASE I - APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    This document summarizes and analyzes the results of a 4-wk evaluation of the Accutech Remedial Systems, Inc. (ARS) Pneumatic Fracturing Extraction™ (PFE™) process for increasing the removal of volatile organic contaminants from the vadose zone, particularly where the ground form...

  2. LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. Troubleshooting of an Electromechanical System (Westinghouse PLC Controlling a Pneumatic Robot). High-Technology Training Module.

    ERIC Educational Resources Information Center

    Tucker, James D.

    This training module on the troubleshooting of an electromechanical system, The Westinghouse Programmable Logic Controller (PLC) controlling a pneumatic robot, is used for a troubleshooting unit in an electromechanical systems/robotics and automation systems course. In this unit, students locate and repair a defect in a PLC-operated machine. The…

  4. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a non... duplicate to the Office of Vehicle Safety Standards, Crash Avoidance Division, National Highway...

  5. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Standard No. 129; New non-pneumatic tires for passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor...

  6. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Standard No. 129; New non-pneumatic tires for passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor...

  7. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a non... duplicate to the Office of Vehicle Safety Standards, Crash Avoidance Division, National Highway...

  8. TECHNOLOGY EVALUATION REPORT: ACCUTECH PNEUMATIC FRACTURING EXTRACTION AND HOT GAS INJECTION

    EPA Science Inventory

    The Pneumatic Fracturing Extraction (PFE) process developed by Accutech Remedial Systems, Inc. makes it possible to use vapor extraction to remove volatile organics at increased rates from a broader range of vadose zones. he low permeability of sits, clays, shales, etc. would oth...

  9. Experimental Development and Evaluation of Pneumatic Powered-Lift Super-STOL Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Campbell, Bryan A.

    2005-01-01

    The powered-lift Channel Wing concept has been combined with pneumatic Circulation Control aerodynamic and propulsive technology to generate a Pneumatic Channel Wing (PCW) configuration intended to have Super-STOL or VSTOL capability while eliminating many of the operational problem areas of the original Channel Wing vehicle. Wind-tunnel development and evaluations of a PCW powered model conducted at Georgia Tech Research Institute (GTRI) have shown substantial lift capabilities for the blown configuration (CL values of 10 to 11). Variation in blowing of the channel was shown to be more efficient than variation in propeller thrust in terms of lift generation. Also revealed was the ability to operate unstalled at very high angles of attack of 40 deg - 45 deg, or to achieve very high lift at much lower angle of attack to increase visibility and controllability. In order to provide greater flexibility in Super-STOL takeoffs and landings, the blown model also displayed the ability to interchange thrust and drag by varying blowing without any moving parts. A preliminary design study of this pneumatic vehicle based on the two technologies integrated into a simple Pneumatic Channel Wing configuration showed very strong Super-STOL potential. This paper presents these experimental results, discusses variations in the configuration geometry under development, and addresses additional considerations to extend this integrated technology to advanced design studies of PCW-type vehicles.

  10. Vacuum pressure generation via microfabricated converging-diverging nozzles for operation of automated pneumatic logic.

    PubMed

    Christoforidis, Theodore; Werner, Erik M; Hui, Elliot E; Eddington, David T

    2016-08-01

    Microfluidic devices with integrated pneumatic logic enable automated fluid handling without requiring external control instruments. These chips offer the additional advantage that they may be powered by vacuum and do not require an electricity source. This work describes a microfluidic converging-diverging (CD) nozzle optimized to generate vacuum at low input pressures, making it suitable for microfluidic applications including powering integrated pneumatic logic. It was found that efficient vacuum pressure was generated for high aspect ratios of the CD nozzle constriction (or throat) width to height and diverging angle of 3.6(o). In specific, for an inlet pressure of 42.2 psia (290.8 kPa) and a volumetric flow rate of approximately 1700 sccm, a vacuum pressure of 8.03 psia (55.3 kPa) was generated. To demonstrate the capabilities of our converging - diverging nozzle device, we connected it to a vacuum powered peristaltic pump driven by integrated pneumatic logic and obtained tunable flow rates from 0 to 130 μL/min. Finally, we demonstrate a proof of concept system for use where electricity and vacuum pressure are not readily available by powering a CD nozzle with a bicycle tire pump and pressure regulator. This system is able to produce a stable vacuum sufficient to drive pneumatic logic, and could be applied to power automated microfluidics in limited resource settings. PMID:27469475

  11. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a...

  12. DEMONSTRATION BULLETIN: PNEUMATIC FRACTURING EXTRACTION™ AND HOT GAS INJECTION, PHASE I - ACCUTECH REMEDIAL SYSTEMS, INC.

    EPA Science Inventory

    The Pneumatic Fracturing Extraction(PFE) process developed by Accutech Remedial Systems, Inc. makes it possible to use vapor extraction to remove volatile organics at increased rates from a broader range of vadose zones. The low permeability of silts, clays, shales, etc. would ot...

  13. Development of Pneumatic Channel Wing Powered-Lift Advanced Super-STOL Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Campbell, Bryan A.

    2002-01-01

    The powered-lift Channel Wing concept has been combined with pneumatic Circulation Control aerodynamic and propulsive technology to generate a Pneumatic Channel Wing configuration intended to have Super-STOL or VSTOL capability while eliminating many of the operational problem areas of the original Channel Wing vehicle. A preliminary design study of this pneumatic vehicle based on previous wind-tunnel and flight-test data for the two technologies integrated into a simple Pneumatic Channel Wing (PCW) configuration showed very strong Super-STOL potential. Wind-tunnel development and evaluations of a PCW powered model conducted at Georgia Tech Research Institute (GTRI) have shown substantial lift capabilities for the blown configuration (C(sub L) values of 8.5 to 9.0). Variation in blowing of the channel was shown to be more efficient than variation in propeller thrust. Also revealed was the ability to operate unstalled at very high angles of attack of 40 deg-45 deg, or to achieve very high lift at much lower angle of attack to increase visibility and controllability. In order to provide greater flexibility in Super-STOL takeoffs and landings, the blown model also displayed the ability to interchange thrust and drag by varying blowing without any moving parts. This paper presents these experimental results, discusses variations in the configuration geometry under development, and extends this integrated technology to advanced design studies of PCW-type vehicles.

  14. Pneumatization of Mastoid Air Cells, Temporal Bone, Ethmoid and Sphenoid Sinuses. Any Correlation?

    PubMed

    Hindi, Khalid; Alazzawi, Sarmad; Raman, Rajagopalan; Prepageran, Narayanan; Rahmat, Kartini

    2014-12-01

    The aim of this study is to assess the pneumatization of the paranasal sinuses (PNS) and other parts of temporal bone such as mastoid air cells and to investigate if there was any association between the aeration of these structures among the three major ethnic groups in Malaysia (Malay, Chinese, Indian) as this would be representative of Asia. A retrospective review of 150 computed tomography (CT) scans of PNS and temporal bones was done and analysed. The pneumatization of each area was obtained and compared using statistical analysis. Patients with a history of previous medical or surgical problems in the intended areas were excluded from the study. The pneumatization of the mastoid air cells and other temporal bone parts were noted to be symmetrical in more than 75 %. There was a positive correlation between the pneumatization of mastoid air cells and that of the sphenoid sinus. The prevalence of Agger nasi, Haller's and Onodi cells was observed to be significantly higher in the Chinese group. Preoperative assessment of the temporal bone and PNS with CT scan may be helpful in the evaluation of their anatomical landmark and decrease the possibility of surgical complications related to 3D structures. PMID:26396957

  15. Numerical Simulation on the Response Characteristics of a Pneumatic Microactuator for Microfluidic Chips.

    PubMed

    Liu, Xuling; Li, Songjing; Bao, Gang

    2016-06-01

    This article presents a multiphysical system modeling and simulation of a pneumatic microactuator, which significantly influences the performance of a particular pneumatic microfluidic device. First, the multiphysical system modeling is performed by developing a physical model for each of its three integrated components: microchannel with a microvalve, a gas chamber, and an elastomer membrane. This is done for each step of operation for the whole system. The whole system is then considered a throttle blind capacitor model, and it is used to predict the response time of the pneumatic microactuator by correlating its characteristics such as gas pressurizing, hydraulic resistance, and membrane deformation. For this microactuator, when the maximum membrane deformation is 100 µm, the required actuated air pressure is 80 kPa, and the response time is 1.67 ms when the valve-opening degree is 0.8. The response time is 1.61 ms under fully open conditions. These simulated results are validated by the experimental results of the current and previous work. A correlation between the simulated and experimental results confirms that the multiphysical modeling presented in this work is applicable in developing a proper design of a pneumatic microactuator. Finally, the influencing factors of the response time are discussed and analyzed. PMID:25944840

  16. 49 CFR 571.139 - Standard No. 139; New pneumatic radial tires for light vehicles.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 139; New pneumatic radial tires for light vehicles. 571.139 Section 571.139 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor...

  17. 49 CFR 571.139 - Standard No. 139; New pneumatic radial tires for light vehicles.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 6 2014-10-01 2014-10-01 false Standard No. 139; New pneumatic radial tires for light vehicles. 571.139 Section 571.139 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor...

  18. Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.

    1990-01-01

    Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

  19. Pneumatic shutoff and time-delay valve operates at controlled rate

    NASA Technical Reports Server (NTRS)

    Horning, J. L.; Tomlinson, L. E.

    1966-01-01

    Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.

  20. The application of pneumatic jigging in the recovery of metallic fraction from shredded printed wiring boards.

    PubMed

    Wang, Zheng; Hall, Philip; Miles, Nicholas J; Wu, Tao; Lambert, Peter; Gu, Fu

    2015-09-01

    Waste electrical and electronic equipment (WEEE) is one of the fastest growing waste streams worldwide with volumes increasing by 40% each year. WEEE has attracted increasing concern worldwide due to its high metal content and the potential environmental threat which results from uncontrolled recycling practices. Innovative physical separation techniques for WEEE recycling are preferential compared with chemical methods because of the reduction of energy and chemical consumption as well as potential environmental threats. Pneumatic jigging is a dry separation process capable of achieving good separation of coarse material within a very narrow density range, which makes it suitable as a pretreatment process for WEEE recycling. The work presented in this paper investigates the potential application of pneumatic jigging in metal recovery from WEEE. A pilot scale pneumatic jig has been developed by University of Nottingham Ningbo to separate shredded printed wiring boards into two streams: a light fraction (mainly non-metallic fraction consisting of glass fiber, fluffs, and plastic pieces) and dense fraction (metallic fraction). The novelty of work presented in this paper is the application of a dry separation technique in WEEE recycling for metal recovery. Compared with conventional wet separation processes involved in WEEE recycling industry, dry separation has the advantage of zero secondary pollution. The results of this experimental program show pneumatic jigging to be an effective and environmental friendly technique as a pretreatment process for the recovery of the metallic fraction from shredded WEEE. PMID:26070501

  1. Challenging In-Situ Strain Measurement In Pneumatic Bulging Of AA5083

    NASA Astrophysics Data System (ADS)

    Liewald, M.; Kappes, J.

    2011-05-01

    Superplastic forming of sheet metal aluminum alloys exhibits numerous technical and economical advantages for manufacturing of complex part geometries in niche type production. For virtual engineering tasks prior manufacturing of superplastic forming equipment such as forming dies, numerical sheet metal forming simulations and material parameters are crucial. In such context the selected testing procedure should be as similar as possible to the subsequent forming technique. For that reason the pneumatic bulge test represents an appropriate testing procedure for the most common superplastic forming process—the blow forming process. In-situ strain measurement of pneumatic bulging AA5083 at 500° C results in high requirements in terms of the grid applied on the blank surface due to process temperature and large strain values. These large strain values result into pole heights up to 70 mm of the bulge test specimens using an initial blank thickness of 1.5 mm and a circular die opening of 100 mm. This paper describes the influence of different grid types and finally proposes adequate grid types for in-situ strain measurement for pneumatic bulging of AA5083. Furthermore the capabilities of in-situ measurement of strains during pneumatic bulging of AA5083 are highlighted.

  2. Aircraft Fuel, Hydraulic and Pneumatic Systems (Course Outlines), Aviation Mechanics 3 (Air Frame): 9067.01.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with the operation, inspection, and repair of aircraft fuel, hydraulic, and pneumatic systems. It is designed to help the trainee master the knowledge and skills necessary to become an aviation airframe mechanic. The aviation airframe maintenance technician…

  3. U.S. ENVIRONMENTAL PROTECTION AGENCY'S SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION OF PNEUMATIC FRACTURING EXTRACTION

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA), in cooperation with Accutech Remedial Systems (ARS) and the New Jersey Institute of Technology (NJIT) performed a field demonstration of Pneumatic Fracturing Extraction (PFE) for the removal of chlorinated volatile organics (VOCS) f...

  4. Comparitive Assessment of Isokinetic and Pneumatic Lower Limb Strength in Functionally-Limited Elderly Subjects

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The purpose of this study was to investigate the relationship between isokinetic and pneumatic knee extensor strength in functionally-limited elders and to compare the respective changes in knee extensor peak torque and one repetition maximum strength (1RM) after a randomized controlled progressive ...

  5. Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.

    1998-01-01

    In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored

  6. Behavioral fever in newborn rabbits

    NASA Technical Reports Server (NTRS)

    Satinoff, E.; Mcewen, G. N., Jr.; Williams, B. A.

    1976-01-01

    New Zealand white rabbit pups aged 12 to 72 hr were divided into three groups and given an intraperitoneal injection of Pseudomonas polysaccharide, a saline vehicle alone, and no treatment, respectively. The animals injected with pyrogen and maintained at an ambient temperature of 32 C for 2 hr did not develop fever. When placed in a thermally graded alleyway, the animals injected with pyrogen selected gradient positions that represented significantly higher temperatures than controls injected with saline. Further stay at selected positions for 5 min caused a considerable increase in the rectal temperature of the pyrogen-injected pups but not that of controls. The results support the hypothesis that newborn rabbits will develop a fever by behavioral means after a single injection of an exogenous pyrogen if the opportunity for thermoregulatory behavior is present. No fever develops if the pups must rely solely on internal thermoregulatory mechanisms. The behavioral system for producing a fever is mature at birth, but an adequate system of internal reflexes does not appear to develop for some days.

  7. Pneumatic vs. door-to-door waste collection systems in existing urban areas: a comparison of economic performance.

    PubMed

    Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina; Ollikainen, Markku; Punkkinen, Henna; Merta, Elina

    2012-10-01

    Pneumatic waste collection systems are becoming increasingly popular in new urban residential areas, and an attractive alternative to conventional vehicle-operated municipal solid waste (MSW) collection also in ready-built urban areas. How well pneumatic systems perform in ready-built areas is, however, an unexplored topic. In this paper, we analyze how a hypothetical stationary pneumatic waste collection system compares economically to a traditional vehicle-operated door-to-door collection system in an existing, densely populated urban area. Both pneumatic and door-to-door collection systems face disadvantages in such areas. While buildings and fixed city infrastructure increase the installation costs of a pneumatic system in existing residential areas, the limited space for waste transportation vehicles and containers cause problems for vehicle-operated waste collection systems. The method used for analyzing the cost effects of the compared waste collection systems in our case study takes into account also monetized environmental effects of both waste collection systems. As a result, we find that the door-to-door collection system is economically almost six times more superior. The dominant cost factor in the analysis is the large investment cost of the pneumatic system. The economic value of land is an important variable, as it is able to reverse the results, if the value of land saved with a pneumatic system is sufficiently high. PMID:22721607

  8. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  9. BESNOITIA ORYCTOFELISI N. SP. (PROTOZOA: APICOMPLEXA) FROM DOMESTIC RABBITS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A species of Besnoitia from naturally infected rabbits from Argentina was propagated experimentally in mice, gerbils, rabbits, cats, and cell cultures. Cats fed tissue cysts from rabbits shed oocysts with a prepatent period of nine to 13 days. Sporulated oocysts were infective to gerbils, rabbits,...

  10. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  11. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system

    SciTech Connect

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer We compare the environmental sustainability of two MSW collection systems. Black-Right-Pointing-Pointer We evaluate pneumatic and door-to-door collection systems. Black-Right-Pointing-Pointer The greenhouse gas emissions of pneumatic collection are around three times higher. Black-Right-Pointing-Pointer System components are decisive but assumptions on electricity use are also important. Black-Right-Pointing-Pointer Pneumatic collection could provide other benefits over door-to-door system. - Abstract: Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO{sub 2} and NO{sub x}. The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a

  12. Additional Development and Systems Analyses of Pneumatic Technology for High Speed Civil Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Willie, F. Scott; Lee, Warren J.

    1999-01-01

    In the Task I portion of this NASA research grant, configuration development and experimental investigations have been conducted on a series of pneumatic high-lift and control surface devices applied to a generic High Speed Civil Transport (HSCT) model configuration to determine their potential for improved aerodynamic performance, plus stability and control of higher performance aircraft. These investigations were intended to optimize pneumatic lift and drag performance; provide adequate control and longitudinal stability; reduce separation flowfields at high angle of attack; increase takeoff/climbout lift-to-drag ratios; and reduce system complexity and weight. Experimental aerodynamic evaluations were performed on a semi-span HSCT generic model with improved fuselage fineness ratio and with interchangeable plain flaps, blown flaps, pneumatic Circulation Control Wing (CCW) high-lift configurations, plain and blown canards, a novel Circulation Control (CC) cylinder blown canard, and a clean cruise wing for reference. Conventional tail power was also investigated for longitudinal trim capability. Also evaluated was unsteady pulsed blowing of the wing high-lift system to determine if reduced pulsed mass flow rates and blowing requirements could be made to yield the same lift as that resulting from steady-state blowing. Depending on the pulsing frequency applied, reduced mass flow rates were indeed found able to provide lift augmentation at lesser blowing values than for the steady conditions. Significant improvements in the aerodynamic characteristics leading to improved performance and stability/control were identified, and the various components were compared to evaluate the pneumatic potential of each. Aerodynamic results were provided to the Georgia Tech Aerospace System Design Lab. to conduct the companion system analyses and feasibility study (Task 2) of theses concepts applied to an operational advanced HSCT aircraft. Results and conclusions from these

  13. Study of the effects of semiconductor laser irradiation on peripheral nerve injury

    NASA Astrophysics Data System (ADS)

    Xiong, G. X.; Li, P.

    2012-11-01

    In order to study to what extent diode laser irradiation effects peripheral nerve injury, the experimental research was made on rabbits. Experimental results show that low-energy semiconductor laser can promote axonal regeneration and improve nervous function. It is also found that simultaneous exposure of the injured peripheral nerve and corresponding spinal segments to laser irradiation may achieve the most significant results.

  14. Surface and biomechanical study of titanium implants modified by laser with and without hydroxyapatite coating, in rabbits.

    PubMed

    Sisti, Karin E; de Rossi, Rafael; Antoniolli, Andreia M Brochado; Aydos, Ricardo D; Guastaldi, Antonio C; Queiroz, Thallita P; Garcia, Idelmo R; Piattelli, Adriano; Tavares, Hewerson S

    2012-06-01

    Surface and biomechanical analysis of titanium implant surfaces modified by laser beam with and without hydroxyapatite. Titanium implants with 3 different surfaces were inserted into the tibias of 30 rabbits: group I (GI) machined surface (control group), group II irradiated with laser (GII), and group III irradiated with laser and hydroxyapatite coating applied-biomimetic method (GIII). Topographical analysis with scanning electron microscopy was made before surgery in the tibia. These rabbits were distributed into 2 periods of observation: 4 and 8 weeks postsurgery, after which biomechanical analysis (removal torque) was conducted. Statistical analysis used the Student-Newman-Keuls method. Surface showed roughness in GII and GIII. Biomechanical analysis demonstrated values with significant differences in GII and GIII. Titanium implants modified by laser irradiation can increase osseointegration during the initial phase. PMID:20690851

  15. Pneumatic active suspension system for a one-wheel car model using fuzzy reasoning and a disturbance observer.

    PubMed

    Yoshimura, Toshio; Takagi, Atsushi

    2004-09-01

    This paper presents the construction of a pneumatic active suspension system for a one-wheel car model using fuzzy reasoning and a disturbance observer. The one-wheel car model can be approximately described as a nonlinear two degrees of freedom system subject to excitation from a road profile. The active control is composed of fuzzy and disturbance controls, and functions by actuating a pneumatic actuator. A phase lead-lag compensator is inserted to counter the performance degradation due to the delay of the pneumatic actuator. The experimental result indicates that the proposed active suspension improves much the vibration suppression of the car model. PMID:15323000

  16. Endoscopic laser reshaping of rabbit tracheal cartilage: preliminary investigations

    NASA Astrophysics Data System (ADS)

    Tsang, Walter; Lam, Anthony; Protsenko, Dmitry; Wong, Brian J.

    2005-04-01

    Background: Tracheal cartilage deformities due to trauma, prolonged endotracheal intubation or infection are difficult to correct. Current treatment options such as dilation, laser ablation, stent placement, and segmental resection are only temporary or carry significant risks. The objectives of this project were to design and test a laser activated endotracheal stent system that can actively modify the geometry of tracheal cartilage, leading to permanent retention of a new and desirable tracheal geometry. Methods: Ex vivo rabbit tracheal cartilage (simulating human neonate trachea) were irradiated with an Er: Glass laser, (λ= 1.54um, 0.5W-2.5W, 1 sec to 5 sec). Shape change and gross thermal injury were assessed visually to determine the best laser power parameters for reshaping. A rigid endoscopic telescope and hollow bronchoscope were used to record endoscopic images. The stent was constructed from nitinol wire, shaped into a zigzag configuration. An ex vivo testing apparatus was also constructed. Results: The best laser power parameter to produce shape change was 1 W for 6-7 seconds. At this setting, there was significant shape change with only minimal thermal injury to the tracheal mucosa, as assessed by visual inspection. The bronchoscopy system functioned adequately during testing in the ex vivo testing apparatus. Conclusion: We have successfully designed instrumentation and created the capability to endoscopically reshape tracheal cartilage in an ex vivo rabbit model. The results obtained in ex vivo tracheal cartilage indicated that reshaping using Er: Glass laser can be accomplished.

  17. Hematologic comparisons of shot and live trapped cottontail rabbits.

    PubMed

    Jacobson, H A; Kirkpatrick, R L; Burkhart, H E; Davis, J W

    1978-01-01

    Comparisons were made between hematologic measurements of shot and box-trapped cottontail rabbits (Sylvilagus floridanus). Trapped rabbits had significantly (P less than 0.001) higher serum corticoid levels and segmented neutrophil percentages and significantly (P less than 0.001) lower lymphocyte percentages than did shot rabbits. Trapped rabbits also had significantly (P less than 0.05) higher packed cell volumes and blood urea nitrogen values than did shot rabbits. PMID:633520

  18. Bobcat attack on a cottontail rabbit

    USGS Publications Warehouse

    Biggins, D.E.; Biggins, D.M.

    2006-01-01

    We observed an attack by a bobcat (Lynx rufus) on a cottontail rabbit (Sylvilagus) that involved stealthy approach by the cat for >1 h, followed by a 12.3-s chase covering 116.0 m for the cat and 128.4 m for the rabbit. During the chase, the route of the cat from starting point to kill site was more direct than the semi-circular route of the rabbit. Stride lengths for the cat and total distance covered by the chase were longer than those previously reported for bobcats.

  19. Type-curve analyses of single- and cross-hole pneumatic tests in unsaturated fractured tuffs

    NASA Astrophysics Data System (ADS)

    Illman, Walter A.; Thompson, Dick L.; Neuman, Shlomo P.

    We describe selected pressure and pressure derivative type-curve analyses of single and cross-hole pneumatic injection tests recently completed in unsaturated fractured tuffs at the Apache Leap Research Site (ALRS) near Superior, Arizona. Type curve analyses of transient data from single-hole tests yield information about air permeability, skin factor, borehole storage, phenomenology and dimensionality of the flow regime on a nominal scale of 1 m in the vicinity of each test interval. We find that transient air permeabilities agree well with steady state values but correlate poorly with fracture density. Larger scale cross-hole pneumatic tests were conducted by injecting air into a relatively short borehole interval of length 1-2 m, while monitoring air pressure and temperature in the injection interval; barometric pressure, air temperature and relative humidity at the surface; as well as air pressure and temperature in 13 short (0.5-2 m) and 24 longer (4-20 m) intervals within the injection and surrounding boreholes. We discuss one of these tests labeled PP4. Analyses of pressure data from individual monitoring intervals yield information about pneumatic connections between the injection and monitoring intervals, corresponding directional air permeabilities, and air-filled porosities. All of these quantities vary considerably from one monitoring interval to another on scales ranging from a few meters to well over 20 meters. Together with the results of earlier site investigations our single and cross-hole test analyses reveal that, at the ALRS, a) the pneumatic pressure behavior of fractured tuff is amenable to analysis by methods that treat the rock as a continuum on scales ranging from meters to tens of meters; b) this continuum is representative primarily of interconnected fractures; c) its pneumatic properties vary strongly with location, direction and scale; in particular, the mean of pneumatic permeabilities increases, and their variance decreases, with

  20. Per-protocol effect of earlier non-pneumatic anti-shock garment application for obstetric hemorrhage

    PubMed Central

    Ayadi, Alison El; Gibbons, Luz; Bergel, Eduardo; Butrick, Elizabeth; Huong, NT MY; Mkumba, Gricelia; Kaseba, Christine; Magwali, Thulani; Merialdi, Mario; Miller, Suellen

    2014-01-01

    Synopsis Earlier non-pneumatic anti-shock garment intervention was highly protective against maternal mortality and morbidity when analyzed to account for intervention fidelity; however, not all outcomes reached statistical significance. PMID:24721615

  1. Rabbit Models for Studying Human Infectious Diseases

    PubMed Central

    Peng, Xuwen; Knouse, John A; Hernon, Krista M

    2015-01-01

    Using an appropriate animal model is crucial for mimicking human disease conditions, and various facets including genetics, anatomy, and pathophysiology should be considered before selecting a model. Rabbits (Oryctolagus cuniculus) are well known for their wide use in production of antibodies, eye research, atherosclerosis and other cardiovascular diseases. However, a systematic description of the rabbit as primary experimental models for the study of various human infectious diseases is unavailable. This review focuses on the human infectious diseases for which rabbits are considered a classic or highly appropriate model, including AIDS (caused by HIV1), adult T-cell leukemia–lymphoma (human T-lymphotropic virus type 1), papilloma or carcinoma (human papillomavirus) , herpetic stromal keratitis (herpes simplex virus type 1), tuberculosis (Mycobacterium tuberculosis), and syphilis (Treponema pallidum). In addition, particular aspects of the husbandry and care of rabbits used in studies of human infectious diseases are described. PMID:26678367

  2. Eyeblink conditioning in the developing rabbit

    PubMed Central

    Brown, Kevin L.; Woodruff-Pak, Diana S.

    2011-01-01

    Eyeblink classical conditioning in pre-weanling rabbits was examined in the present study. Using a custom lightweight headpiece and restrainer, New Zealand white littermates were trained once daily in 400 ms delay eyeblink classical conditioning from postnatal days (PD) 17–21 or PD 24–28. These ages were chosen because eyeblink conditioning emerges gradually over PD 17–24 in rats (Stanton, Freeman, & Skelton, 1992), another altricial species with neurodevelopmental features similar to those of rabbits. Consistent with well-established findings in rats, rabbits trained from PD 24–28 showed greater conditioning relative to littermates trained from PD 17–21. Both age groups displayed poor retention of eyeblink conditioning at retraining one month after acquisition. These findings are the first to demonstrate eyeblink conditioning in the developing rabbit. With further characterization of optimal conditioning parameters, this preparation may have applications to neurodevelopmental disease models as well as research exploring the ontogeny of memory. PMID:21953433

  3. Rabbit Models for Studying Human Infectious Diseases.

    PubMed

    Peng, Xuwen; Knouse, John A; Hernon, Krista M

    2015-12-01

    Using an appropriate animal model is crucial for mimicking human disease conditions, and various facets including genetics, anatomy, and pathophysiology should be considered before selecting a model. Rabbits (Oryctolagus cuniculus) are well known for their wide use in production of antibodies, eye research, atherosclerosis and other cardiovascular diseases. However, a systematic description of the rabbit as primary experimental models for the study of various human infectious diseases is unavailable. This review focuses on the human infectious diseases for which rabbits are considered a classic or highly appropriate model, including AIDS (caused by HIV1), adult T-cell leukemia-lymphoma (human T-lymphotropic virus type 1), papilloma or carcinoma (human papillomavirus) , herpetic stromal keratitis (herpes simplex virus type 1), tuberculosis (Mycobacterium tuberculosis), and syphilis (Treponema pallidum). In addition, particular aspects of the husbandry and care of rabbits used in studies of human infectious diseases are described. PMID:26678367

  4. Oritavancin Pharmacokinetics and Bone Penetration in Rabbits

    PubMed Central

    Ostiguy, Valerie; Cadieux, Cordelia; Malouin, Mireille; Belanger, Odette; Far, Adel Rafai; Parr, Thomas R.

    2015-01-01

    The pharmacokinetics and bone concentrations of oritavancin were investigated after a single intravenous dose was administered to rabbits. The pharmacokinetic profile of oritavancin in rabbits showed that it is rapidly distributed to bone tissues, with concentrations remaining stable for up to 168 h, the last measured time point. Based on these findings, further evaluation of oritavancin for the treatment of infections in bone tissues is warranted. PMID:26239977

  5. Photoacoustic endoscopic imaging of the rabbit mediastinum

    NASA Astrophysics Data System (ADS)

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Li, Chiye; Maslov, Konstantin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2013-03-01

    Like ultrasound endoscopy, photoacoustic endoscopy (PAE) could become a valuable addition to clinical practice due to its deep imaging capability. Results from our recent in vivo transesophageal endoscopic imaging study on rabbits demonstrate the technique's capability to image major organs in the mediastinal region, such as the lung, trachea, and cardiovascular systems. Here, we present various features from photoacoustic images from the mediastinal region of several rabbits and discuss possible clinical contributions of this technique and directions of future technology development.

  6. Genomic Analysis of Companion Rabbit Staphylococcus aureus

    PubMed Central

    Holmes, Mark A.; Harrison, Ewan M.; Fisher, Elizabeth A.; Graham, Elizabeth M.; Parkhill, Julian; Foster, Geoffrey; Paterson, Gavin K.

    2016-01-01

    In addition to being an important human pathogen, Staphylococcus aureus is able to cause a variety of infections in numerous other host species. While the S. aureus strains causing infection in several of these hosts have been well characterised, this is not the case for companion rabbits (Oryctolagus cuniculus), where little data are available on S. aureus strains from this host. To address this deficiency we have performed antimicrobial susceptibility testing and genome sequencing on a collection of S. aureus isolates from companion rabbits. The findings show a diverse S. aureus population is able to cause infection in this host, and while antimicrobial resistance was uncommon, the isolates possess a range of known and putative virulence factors consistent with a diverse clinical presentation in companion rabbits including severe abscesses. We additionally show that companion rabbit isolates carry polymorphisms within dltB as described as underlying host-adaption of S. aureus to farmed rabbits. The availability of S. aureus genome sequences from companion rabbits provides an important aid to understanding the pathogenesis of disease in this host and in the clinical management and surveillance of these infections. PMID:26963381

  7. Complement activation induced by rabbit rheumatoid factor.

    PubMed Central

    Meyer, R R; Brown, J C

    1980-01-01

    Rabbit rheumatoid factor produced in animals by hyperimmunized with group C streptococcal vaccine activated guinea pig complement. Anti-streptococcal serum was fractionated by Sephacryl S-200 chromatography into excluded (19S) and included (7S) material and examined for hemolytic activity in a sensitive homologous hemolytic assay system. In the presence of complement, both 19S and 7S antistreptococcal serum fractions induced lysis of bovine (ox) erythrocytes coated with mildly reduced and carboxymethylated rabbit anti-erythrocyte immunoglobulin G. That rabbit rheumatoid factor was responsible for the observed hemolytic activity was substantiated by hemolytic inhibition assays. Significant inhibition of hemolysis was effected when antistreptococcal serum fractions were incubated in the presence of human immunoglobulin G, rabbit immunoglobulin G, and Fc, whereas, no inhibition was detected when the same fractions were tested in the presence of rabbit Fab or F(ab')2 fragments. Deaggregation of inhibitor preparations revealed a preferential reactivity of rheumatoid factor for rabbit immunoglobulin G. In addition to the rheumatoid factor-dependent hemolytic activity observed in humoral preparations, immunoglobulin G-specific antibody-forming cells in spleen and peripheral blood lymphocyte isolates were enumerated by plaque-forming cell assay. PMID:7399707

  8. Genomic Analysis of Companion Rabbit Staphylococcus aureus.

    PubMed

    Holmes, Mark A; Harrison, Ewan M; Fisher, Elizabeth A; Graham, Elizabeth M; Parkhill, Julian; Foster, Geoffrey; Paterson, Gavin K

    2016-01-01

    In addition to being an important human pathogen, Staphylococcus aureus is able to cause a variety of infections in numerous other host species. While the S. aureus strains causing infection in several of these hosts have been well characterised, this is not the case for companion rabbits (Oryctolagus cuniculus), where little data are available on S. aureus strains from this host. To address this deficiency we have performed antimicrobial susceptibility testing and genome sequencing on a collection of S. aureus isolates from companion rabbits. The findings show a diverse S. aureus population is able to cause infection in this host, and while antimicrobial resistance was uncommon, the isolates possess a range of known and putative virulence factors consistent with a diverse clinical presentation in companion rabbits including severe abscesses. We additionally show that companion rabbit isolates carry polymorphisms within dltB as described as underlying host-adaption of S. aureus to farmed rabbits. The availability of S. aureus genome sequences from companion rabbits provides an important aid to understanding the pathogenesis of disease in this host and in the clinical management and surveillance of these infections. PMID:26963381

  9. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system.

    PubMed

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-01

    Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive. PMID:22647502

  10. Late skin damage in rabbits and monkeys after exposure to particulate radiations

    NASA Technical Reports Server (NTRS)

    Bergtold, D. S.; Cox, A. B.; Lett, J. T.; Su, C. M.

    1983-01-01

    Preliminary results are reported of experiments on the late effects of exposure to particulate radiations on stem cell populations. Skin biopsies were taken from the ears of rabbits irradiated 2-5 years previously with 530 MeV/amu Ar ions (LET 90 keV/micron), or 365 MeV/amu Ne ions (LET 35 keV micron), and from the chests and inner thighs of rhesus monkeys irradiated 16-18 years previously with 32-MeV protons (LET about 1.2 keV/micron). Skin fibroblast cultures obtained from the biopsy samples in rabbits were observed to undergo dose-dependent decreases in in vitro life span, with estimated survival curves showing the effects of Ar-ion irradiation to be more severe than those of Ne-ion irradiation. In addition, the healing of the biopsy wound was observed to become slower as radiation dose increased. In the monkey, radiation reduced the average number of fibroblasts at the time of cessation of growth in culture. Results thus demonstrate the capacity of skin sampling to reveal stem cell destruction, and have important implications for astronauts and other persons at risk of particle exposure with regard to healing responses to trauma or surgery.

  11. The role of myofibroblasts in the development of osteoradionecrosis in a newly established rabbit model.

    PubMed

    Zong, Chunlin; Cai, Bolei; Wen, Xinxin; Alam, Syed; Chen, Yuanli; Guo, Yuxuan; Liu, Yanpu; Tian, Lei

    2016-06-01

    This study aimed to establish a proper animal model of osteoradionecrosis of jaws (ORNJ) and to observe preliminarily the characteristics of myofibroblasts, the key effector cell of fibrosis, in ORNJ. Rabbit mandibles were irradiated at three different doses based on a human equivalent radiation schedule, and examined by gross manifestation, single-photon emission computed tomography (SPECT), micro-computed tomography, sequential fluorochrome labeling, and histology. Immunohistochemistry staining of α-SMA was applied to detect the existence of myofibroblasts. The exposed necrotic bone, which is the main indication of ORNJ, started to be observed at all rabbits at 9 Gy. With the radiation dose increasing, the microarchitecture of the irradiated mandibles was more destroyed, the metabolism and mineralization of the irradiated mandibles diminished, the osteocytes number decreased, and more mature bones were substituted by fibrosis in the irradiated mandibles. In addition, as the radiation dose increased, the myofibroblast number increased and collected around the separated sequestrum, which indicated that myofibroblasts might relate to the pathogenesis of ORNJ. In summary, a clinically translational ORNJ model was successfully established in our study, and the role of myofibroblasts in the pathogenesis of ORNJ is described for the first time. PMID:27150352

  12. Pulmonary toxicity in a rabbit model of stereotactic lung radiation therapy: efficacy of a radioprotector.

    PubMed

    Mata, Jaime; Sheng, Ke; Hagspiel, Klaus; Ruppert, Kai; Sylvester, Peter; Mugler, John; Fernandes, Carolina; Guan, Steven; Larner, James; Read, Paul

    2014-08-01

    This study aimed to assess the efficacy of the radioprotector amifostine in limiting radiation toxicity in a rabbit model of lung stereotactic body radiation therapy (SBRT) by correlating contrast-enhanced magnetic resonance angiography (ce-MRA), computed tomography (CT), and helium-3 (He-3) magnetic resonance imaging (MRI) with histopathology. Multiple MRI techniques were tested to obtain complementing physiologic information. Thirteen rabbits received SBRT to the right lower lobe of the lung. Specifically, 4 received 3 × 11 Gray (Gy), 6 received 3 × 11 Gy and 50 mg/kg of amifostine pre-SRBT, and 3 received 3 × 7, 3 × 9, or 3 × 13 Gy. Imaging was performed at baseline and 4, 8, 12, and 16 weeks post-SBRT. Ce-MRA perfusion difference between lungs in the irradiated group at 16 weeks post-treatment was statistically significant (P = .04) whereas the difference in the irradiated + amifostine group was not (P = .30). Histologically observed low red blood cell (RBC) count and CT hypodensity suggests changes were primarily related to perfusion; however, structural changes, such as increased alveolar size, were also present. No changes in He-3 MRI lung ventilation were observed in either group. Although radiation-induced injury detected in rabbits as CT hypodensity contrasted with increased density observed in humans/rodents, the changes in ce-MRA and CT were still significantly reduced after the addition of amifostine to SBRT. Use of CT and selected MRI techniques helped to pinpoint primary physiologic changes. PMID:24926529

  13. A comparison of hydraulic, pneumatic, and electro-mechanical actuators for general aviation flight controls

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Rice, M.; Eysink, H.

    1979-01-01

    Mathematical models for electromechanical (EM), pneumatic and hydraulic actuations are discussed. It is shown that EM and hydraulic actuators provide better and faster time responses than pneumatic actuators but EM actuators utilizing the recently developed samarium-cobalt technology have significant advantages in terms of size, weight and power requirements. In terms of ease and flexibility of installation EM actuators apparently have several advantages over hydraulic actuators, and cost is a primary reason for the popularity of EM actuation for secondary control function since no additional systems need to be added to the aircraft. While new rare earth magnets are currently in developmental stage, costs are relatively high; but continued research should bring prices down.

  14. Transient Analysis of Pressurization and Pneumatic Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Knight, K. C.; Chamption, R. H., Jr.; Kennedy, Jim W. (Technical Monitor)

    2000-01-01

    Transient models for the pressurization, vent/relief, and pneumatic subsystems of the X-34 Main Propulsion System are presented and simulation of their operation within prescribed requirements are provided. First, using ROCket Engine Transient Simulation (ROCETS) program, pressurization subsystem operation was simulated and helium requirements and the ullage thermodynamic condition within each propellant tank were calculated. Then, Overpressurization scenarios of propellant tanks and the response of vent/relief valves were evaluated using ROCETS simulation of simultaneous operation of the pressurization and vent/relief subsystems by incorporating the valves data into the model. Finally, the ROCETS simulation of in-flight operation of pneumatic subsystem predicted the overall helium consumption, Inter-Propellant Seal (IPS) purge flowrate and thermodynamic conditions, and Spin Start power.

  15. System for the pulsed pneumatic transport of ash from ash-collector bins

    SciTech Connect

    E.V. Chernyshev; S.N. Kochurov; V.A. Il'in; V.V. Ermakov

    2007-07-15

    Results of investigations of the dependence of the percentage of voids on the shear force of a layer of ash, on the basis of which the design principle of the subassembly for the feed of ash to a transport pipeline is developed, are examined for optimization of ash flows in a pulsed regime. The schematic of a system of pulsed pneumatic transport of ash from the bins of ash collectors, and results of measurements during experimental operation of the system, as well as relationships for the calculation of its dynamic parameters are presented. Conclusions concerning the high reliability of the removal and pneumatic transport of ash over a distance of more than 80 m with minimal air consumption are drawn on the basis of results of the experimental operation.

  16. Management of retinal detachment in block related globe perforation with pneumatic retinopexy.

    PubMed

    Rishi, Karandeep; Venkatesh, Pradeep; Garg, Satpal P

    2013-03-01

    Retinal detachment after ocular perforation related to local anesthesia is a common complication, which is usually associated with a poor prognosis despite complex vitreoretinal surgical procedures. We report a case of 62-year-old male with cataract surgery done 4 weeks back with nasal retinal detachment with a posterior break. Pneumatic retinopexy was performed and laser barrage of the breaks was done the next day when the retina got attached. A vision of 20/30 was achieved at the end of 2 months. To the best of our knowledge, this is a first case report in literature where pneumatic retinopexy was used to manage a retinal detachment caused by block-related perforation. PMID:23514652

  17. Radiation Damage Study in Natural Zircon Using Neutrons Irradiation

    SciTech Connect

    Lwin, Maung Tin Moe; Amin, Yusoff Mohd.; Kassim, Hasan Abu; Mohamed, Abdul Aziz; Karim, Julia Abdul

    2011-03-30

    Changes of atomic displacements in crystalline structure of natural zircon (ZrSiO{sub 4}) can be studied by using neutron irradiation on the surface of zircon and compared the data from XRD measurements before and after irradiation. The results of neutron irradiation on natural zircon using Pneumatic Transfer System (PTS) at PUSPATI TRIGA Research Reactor in the Malaysian Nuclear Agency are discussed in this work. The reactor produces maximum thermal power output of 1 MWatt and the neutron flux of up to 1x10{sup 13} ncm{sup -2}s{sup -1}. From serial decay processes of uranium and thorium radionuclides in zircon crystalline structure, the emission of alpha particles can produce damage in terms of atomic displacements in zircon. Hence, zircon has been extensively studied as a possible candidate for immobilization of fission products and actinides.

  18. Radiation Damage Study in Natural Zircon Using Neutrons Irradiation

    NASA Astrophysics Data System (ADS)

    Lwin, Maung Tin Moe; Amin, Yusoff Mohd.; Kassim, Hasan Abu; Mohamed, Abdul Aziz; Karim, Julia Abdul

    2011-03-01

    Changes of atomic displacements in crystalline structure of natural zircon (ZrSiO4) can be studied by using neutron irradiation on the surface of zircon and compared the data from XRD measurements before and after irradiation. The results of neutron irradiation on natural zircon using Pneumatic Transfer System (PTS) at PUSPATI TRIGA Research Reactor in the Malaysian Nuclear Agency are discussed in this work. The reactor produces maximum thermal power output of 1 MWatt and the neutron flux of up to 1×1013 ncm-2s-1. From serial decay processes of uranium and thorium radionuclides in zircon crystalline structure, the emission of alpha particles can produce damage in terms of atomic displacements in zircon. Hence, zircon has been extensively studied as a possible candidate for immobilization of fission products and actinides.

  19. Isolated bilateral blowout fracture with extensive pneumatization of the maxillary sinuses.

    PubMed

    Corrrêa, Ana Paula Simões; Boss, Fernanda Brasil Daura Jorge; Coléte, Juliana Zorzzi; Porzoni, Daniela; Bassi, Ana Paula Farnezi; Aranega, Alessandra Marcondes; Ávila Souza, Francisley; Garcia-Júnior, Idelmo Rangel

    2014-07-01

    The blowout fracture injuries are often associated with fractures of the zygomatic complex and other facial structures but can also occur in an isolated fashion. Isolated bilateral blowout fractures are uncommon and constitute a challenge with regard to both assessment and reconstruction. This article describes an uncommon case of isolated bilateral blowout fracture in a patient with extensive pneumatization of the maxillary sinuses. PMID:24902117

  20. Pneumatic colon injury following high pressure blow gun dust cleaner spray to the perineum

    PubMed Central

    Sy, Edgar D.; Chiu, Yin-I.; Shan, Yan-Shen; Ong, Roger L.

    2014-01-01

    Introduction A pneumatic tool or air tool such as blow gun dust cleaner is a tool driven by compressed air and spraying of the perineum can insufflate the colon due to its high pressure and high flow rate. Presentation of case We present a case of 4 year old boy who developed sudden onset of tense abdominal distention and developed peritonitis. Patient’s family initially denied a history of trauma. Radiologic examination showed pneumoperitoneum and colon dilatation. Exploratory laparotomy revealed a tension pneumoperitoneum, bloody ascitic fluid, multiple site of ecchymosis and serosal tear of the colon and a minute perforation of transverse colon. Postoperative reinvestigation revealed that the patient’s perineum was sprayed, using blow gun dust cleaner. Discussion Air from pneumatic tools produces column of air at pressure of 3.5–8.8 kg/cm2 and pressure greater than the resting anal pressure of 0.109 kg/cm2 force air to enter the colon when the perineum is sprayed. Different degree of colon injury results when airflow is greater than 1.46 L/m, and/or intraluminal pressure greater than 0.109 kg/cm2. In most children, initial anxiety to tell the truth result in difficulty to obtain good history. Conclusion Spraying of the perianal with excessive pneumatic force of greater than the resting anal pressure and high air flow rate causes multiple site colon injury and tension pneumoperitoneum due to colon perforation. Parent should be caution in children playing with high pressure pneumatic tool, and the importance of history is emphases for early correct diagnosis. PMID:25544492

  1. Hydraulic anisotropy characterization of pneumatic-fractured sediments using azimuthal self potential gradient

    USGS Publications Warehouse

    Wishart, D.N.; Slater, L.D.; Schnell, D.L.; Herman, G.C.

    2009-01-01

    The pneumatic fracturing technique is used to enhance the permeability and porosity of tight unconsolidated soils (e.g. clays), thereby improving the effectiveness of remediation treatments. Azimuthal self potential gradient (ASPG) surveys were performed on a compacted, unconsolidated clay block in order to evaluate their potential to delineate contaminant migration pathways in a mechanically-induced fracture network. Azimuthal resistivity (ARS) measurements were also made for comparative purposes. Following similar procedures to those used in the field, compressed kaolinite sediments were pneumatically fractured and the resulting fracture geometry characterized from strike analysis of visible fractures combined with strike data from optical borehole televiewer (BHTV) imaging. We subsequently injected a simulated treatment (electrolyte/dye) into the fractures. Both ASPG and ARS data exhibit anisotropic geoelectric signatures resulting from the fracturing. Self potentials observed during injection of electrolyte are consistent with electrokinetic theory and previous laboratory results on a fracture block model. Visual (polar plot) analysis and linear regression of cross plots show ASPG lobes are correlated with azimuths of high fracture strike density, evidence that the ASPG anisotropy is a proxy measure of hydraulic anisotropy created by the pneumatic fracturing. However, ARS data are uncorrelated with fracture strike maxima and resistivity anisotropy is probably dominated by enhanced surface conduction along azimuths of weak 'starter paths' formed from pulverization of the clay and increases in interfacial surface area. We find the magnitude of electrokinetic SP scales with the applied N2 gas pressure gradient (??PN2) for any particular hydraulically-active fracture set and that the positive lobe of the ASPG anomaly indicates the flow direction within the fracture network. These findings demonstrate the use of ASPG in characterizing the effectiveness of (1

  2. A Randomized Controlled Trial of Massage and Pneumatic Compression for Ultramarathon Recovery.

    PubMed

    Hoffman, Martin D; Badowski, Natalie; Chin, Joseph; Stuempfle, Kristin J

    2016-05-01

    Study Design Randomized controlled trial. Background Postexercise recovery techniques are widely used, but little research has examined their effectiveness. Objectives To examine the effectiveness of massage and pneumatic compression on recovery from a 161-km ultramarathon. Methods Participants in the 2015 161-km Western States Endurance Run were randomized to a 20-minute postrace intervention of massage, intermittent sequential pneumatic compression, or supine rest. Each subject completed two 400-m runs at maximum speed before the race and on days 3 and 5 after the race, and also provided muscle pain and soreness ratings and overall muscular fatigue scores before and for 7 days after the race. Results Among the 72 runners who finished the race and completed the study, comparison among intervention groups revealed no significant group or interaction effect on 400-m run time, but there was a significant (P<.0001) time effect. Immediately posttreatment, massage resulted in lower muscle pain and soreness ratings compared with the supine-rest control condition (P<.0001), while both massage (P<.0001) and pneumatic compression (P<.01) resulted in lower overall muscular fatigue scores compared with the control group. There were no significant differences between groups in any outcome 1 to 7 days after the race. Conclusion Single 20-minute sessions of postrace massage and intermittent sequential pneumatic compression provide some immediate subjective benefit. There is no evidence, however, that such treatments provide extended subjective or functional benefits of clinical importance. The trial was registered at www.clinicaltrials.gov (NCT02530190). Level of Evidence Therapy, level 1b. J Orthop Sports Phys Ther 2016;46(5):320-326. Epub 23 Mar 2016. doi:10.2519/jospt.2016.6455. PMID:27011305

  3. Feasibility and testing of lighweight, energy efficient, additive manufactured pneumatic control valve

    SciTech Connect

    Love, Lonnie J.; Mell, Ellen

    2015-02-01

    AeroValve s innovative pneumatic valve technology recycles compressed air through the valve body with each cycle of the valve, and was reported to reduce compressed air requirements by an average of 25% 30%.This technology collaboration project between ORNL and Aerovalve confirms the energy efficiency of valve performance. Measuring air consumption per work completed, the AeroValve was as much as 85% better than the commercial Festo valve.

  4. Development of Pneumatic Aerodynamic Devices to Improve the Performance, Economics, and Safety of Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2000-06-19

    Under contract to the DOE Office of Heavy Vehicle Technologies, the Georgia Tech Research Institute (GTRI) is developing and evaluating pneumatic (blown) aerodynamic devices to improve the performance, economics, stability and safety of operation of Heavy Vehicles. The objective of this program is to apply the pneumatic aerodynamic aircraft technology previously developed and flight-tested by GTRI personnel to the design of an efficient blown tractor-trailer configuration. Recent experimental results obtained by GTRI using blowing have shown drag reductions of 35% on a streamlined automobile wind-tunnel model. Also measured were lift or down-load increases of 100-150% and the ability to control aerodynamic moments about all 3 axes without any moving control surfaces. Similar drag reductions yielded by blowing on bluff afterbody trailers in current US trucking fleet operations are anticipated to reduce yearly fuel consumption by more than 1.2 billion gallons, while even further reduction is possible using pneumatic lift to reduce tire rolling resistance. Conversely, increased drag and down force generated instantaneously by blowing can greatly increase braking characteristics and control in wet/icy weather due to effective ''weight'' increases on the tires. Safety is also enhanced by controlling side loads and moments caused on these Heavy Vehicles by winds, gusts and other vehicles passing. This may also help to eliminate the jack-knifing problem if caused by extreme wind side loads on the trailer. Lastly, reduction of the turbulent wake behind the trailer can reduce splash and spray patterns and rough air being experienced by following vehicles. To be presented by GTRI in this paper will be results developed during the early portion of this effort, including a preliminary systems study, CFD prediction of the blown flowfields, and design of the baseline conventional tractor-trailer model and the pneumatic wind-tunnel model.

  5. Hydraulic anisotropy characterization of pneumatic-fractured sediments using azimuthal self potential gradient

    NASA Astrophysics Data System (ADS)

    Wishart, DeBonne N.; Slater, Lee D.; Schnell, Deborah L.; Herman, Gregory C.

    2009-01-01

    The pneumatic fracturing technique is used to enhance the permeability and porosity of tight unconsolidated soils (e.g. clays), thereby improving the effectiveness of remediation treatments. Azimuthal self potential gradient (ASPG) surveys were performed on a compacted, unconsolidated clay block in order to evaluate their potential to delineate contaminant migration pathways in a mechanically-induced fracture network. Azimuthal resistivity (ARS) measurements were also made for comparative purposes. Following similar procedures to those used in the field, compressed kaolinite sediments were pneumatically fractured and the resulting fracture geometry characterized from strike analysis of visible fractures combined with strike data from optical borehole televiewer (BHTV) imaging. We subsequently injected a simulated treatment (electrolyte/dye) into the fractures. Both ASPG and ARS data exhibit anisotropic geoelectric signatures resulting from the fracturing. Self potentials observed during injection of electrolyte are consistent with electrokinetic theory and previous laboratory results on a fracture block model. Visual (polar plot) analysis and linear regression of cross plots show ASPG lobes are correlated with azimuths of high fracture strike density, evidence that the ASPG anisotropy is a proxy measure of hydraulic anisotropy created by the pneumatic fracturing. However, ARS data are uncorrelated with fracture strike maxima and resistivity anisotropy is probably dominated by enhanced surface conduction along azimuths of weak 'starter paths' formed from pulverization of the clay and increases in interfacial surface area. We find the magnitude of electrokinetic SP scales with the applied N 2 gas pressure gradient (Δ PN2) for any particular hydraulically-active fracture set and that the positive lobe of the ASPG anomaly indicates the flow direction within the fracture network. These findings demonstrate the use of ASPG in characterizing the effectiveness of (1

  6. NK-1 Removable Cryogenic Shroud (A Study of the Bimba Pneumatic Cylinder)

    SciTech Connect

    Anderson, K; Stefanescu, D

    2003-02-07

    The Mark 1 Cryostat requires a cryogenic shroud that must be retracted immediately before firing the NIF laser. This paper evaluates a pneumatic cylinder that has been chosen to open and close the shroud. After a variety of motion control and vacuum compatibility experiments, we concluded that the Bimba feedback control cylinder may be used to retract the shroud with certain modifications to its control system and additional rod seals.

  7. A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop

    PubMed Central

    Chin, Robin; Hsiao-Wecksler, Elizabeth T; Loth, Eric; Kogler, Géza; Manwaring, Scott D; Tyson, Serena N; Shorter, K Alex; Gilmer, Joel N

    2009-01-01

    Background A self-contained, self-controlled, pneumatic power harvesting ankle-foot orthosis (PhAFO) to manage foot-drop was developed and tested. Foot-drop is due to a disruption of the motor control pathway and may occur in numerous pathologies such as stroke, spinal cord injury, multiple sclerosis, and cerebral palsy. The objectives for the prototype PhAFO are to provide toe clearance during swing, permit free ankle motion during stance, and harvest the needed power with an underfoot bellow pump pressurized during the stance phase of walking. Methods The PhAFO was constructed from a two-part (tibia and foot) carbon composite structure with an articulating ankle joint. Ankle motion control was accomplished through a cam-follower locking mechanism actuated via a pneumatic circuit connected to the bellow pump and embedded in the foam sole. Biomechanical performance of the prototype orthosis was assessed during multiple trials of treadmill walking of an able-bodied control subject (n = 1). Motion capture and pressure measurements were used to investigate the effect of the PhAFO on lower limb joint behavior and the capacity of the bellow pump to repeatedly generate the required pneumatic pressure for toe clearance. Results Toe clearance during swing was successfully achieved during all trials; average clearance 44 ± 5 mm. Free ankle motion was observed during stance and plantarflexion was blocked during swing. In addition, the bellow component repeatedly generated an average of 169 kPa per step of pressure during ten minutes of walking. Conclusion This study demonstrated that fluid power could be harvested with a pneumatic circuit built into an AFO, and used to operate an actuated cam-lock mechanism that controls ankle-foot motion at specific periods of the gait cycle. PMID:19527526

  8. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed Central

    Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.

    2016-01-01

    Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719

  9. Mechanoreceptors and length of the patellar ligament after Ho-YAG laser treatment: a long-term follow-up in rabbits.

    PubMed

    Takahashi, Toshiaki; Wada, Yukihisa; Tanaka, Masanobu; Yamanaka, Norio; Yamamoto, Hiroshi

    2002-12-01

    We studied the shortening and the number of mechanoreceptors in the patellar ligament up to 18 months after Ho-YAG irradiation of the ligament's surface in 35 rabbits. The ligaments shortened an average 13% immediately after irradiation. After treatment, we divided the rabbits into a mobilized or immobilized group. At 2 weeks and 12 months after treatment both groups showed no shortening of the ligament, as compared to the intact ligament while that in the mobilized group had elongated at 12 months. Fewer Pacinian and Ruffini corpuscles were found in the irradiated ligaments than in the intact ones at 2 weeks after treatment, but we found no difference between irradiated and intact ligaments at 18 months after treatment. PMID:12553512

  10. Serologic evidence for rabbit syncytium virus in eastern cottontail rabbits (Sylvilagus floridanus) in Ohio.

    PubMed

    Theil, K W; McCloskey, C M; Scott, D P

    1993-07-01

    Thirteen of 20 eastern cottontail rabbit (Sylvilagus floridanus) sera collected near Delaware, Ohio (USA) in 1991 were positive by indirect immunofluorescent antibody test (IFAT) for antibody to rabbit syncytium virus (RSV), a Kemerovo serogroup orbivirus. In addition, two of 10 domestic bovine sera and three of 30 sheep sera collected in southeastern Ohio gave weak positive IFAT reactions to RSV. PMID:8394944

  11. Extreme Mechanics in Soft Pneumatic Robots and Soft Microfluidic Electronics and Sensors

    NASA Astrophysics Data System (ADS)

    Majidi, Carmel

    2012-02-01

    In the near future, machines and robots will be completely soft, stretchable, impact resistance, and capable of adapting their shape and functionality to changes in mission and environment. Similar to biological tissue and soft-body organisms, these next-generation technologies will contain no rigid parts and instead be composed entirely of soft elastomers, gels, fluids, and other non-rigid matter. Using a combination of rapid prototyping tools, microfabrication methods, and emerging techniques in so-called ``soft lithography,'' scientists and engineers are currently introducing exciting new families of soft pneumatic robots, soft microfluidic sensors, and hyperelastic electronics that can be stretched to as much as 10x their natural length. Progress has been guided by an interdisciplinary collection of insights from chemistry, life sciences, robotics, microelectronics, and solid mechanics. In virtually every technology and application domain, mechanics and elasticity have a central role in governing functionality and design. Moreover, in contrast to conventional machines and electronics, soft pneumatic systems and microfluidics typically operate in the finite deformation regime, with materials stretching to several times their natural length. In this talk, I will review emerging paradigms in soft pneumatic robotics and soft microfluidic electronics and highlight modeling and design challenges that arise from the extreme mechanics of inflation, locomotion, sensor operation, and human interaction. I will also discuss perceived challenges and opportunities in a broad range of potential application, from medicine to wearable computing.

  12. Manually Operatable On-Chip Bistable Pneumatic Microstructures for Microfluidic Manipulations

    PubMed Central

    Chen, A.; Pan, T.

    2014-01-01

    Bistable microvalves are of particular interest because of their distinct nature requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries for microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integratability and small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPM) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly comprised of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), which users have direct control through finger pressing to switch between bistable vacuum state (VS) or atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that process blood samples to identify the distinct blood types (A/B/O) on chip. PMID:25007840

  13. Dynamics of a pneumatic artificial muscle actuation system driving a trailing edge flap

    NASA Astrophysics Data System (ADS)

    Woods, Benjamin K. S.; Kothera, Curt S.; Wang, Gang; Wereley, Norman M.

    2014-09-01

    This study presents a time domain dynamic model of an antagonistic pneumatic artificial muscle (PAM) driven trailing edge flap (TEF) system for next generation active helicopter rotors. Active rotor concepts are currently being widely researched in the rotorcraft community as a means to provide a significant leap forward in performance through primary aircraft control, vibration mitigation and noise reduction. Recent work has shown PAMs to be a promising candidate for active rotor actuation due to their combination of high force, large stroke, light weight, and suitable bandwidth. When arranged into biologically inspired agonist/antagonist muscle pairs they can produce bidirectional torques for effectively driving a TEF. However, there are no analytical dynamic models in the literature that can accurately capture the behavior of such systems across the broad range of frequencies required for this demanding application. This work combines mechanical, pneumatic, and aerodynamic component models into a global flap system model developed for the Bell 407 rotor system. This model can accurately predict pressure, force, and flap angle response to pneumatic control valve inputs over a range of operating frequencies from 7 to 35 Hz (1/rev to 5/rev for the Bell 407) and operating pressures from 30 to 90 psi.

  14. Direct adaptive fuzzy control of a translating piezoelectric flexible manipulator driven by a pneumatic rodless cylinder

    NASA Astrophysics Data System (ADS)

    Qiu, Zhi-cheng; Wang, Bin; Zhang, Xian-min; Han, Jian-da

    2013-04-01

    This study presents a novel translating piezoelectric flexible manipulator driven by a rodless cylinder. Simultaneous positioning control and vibration suppression of the flexible manipulator is accomplished by using a hybrid driving scheme composed of the pneumatic cylinder and a piezoelectric actuator. Pulse code modulation (PCM) method is utilized for the cylinder. First, the system dynamics model is derived, and its standard multiple input multiple output (MIMO) state-space representation is provided. Second, a composite proportional derivative (PD) control algorithms and a direct adaptive fuzzy control method are designed for the MIMO system. Also, a time delay compensation algorithm, bandstop and low-pass filters are utilized, under consideration of the control hysteresis and the caused high-frequency modal vibration due to the long stroke of the cylinder, gas compression and nonlinear factors of the pneumatic system. The convergence of the closed loop system is analyzed. Finally, experimental apparatus is constructed and experiments are conducted. The effectiveness of the designed controllers and the hybrid driving scheme is verified through simulation and experimental comparison studies. The numerical simulation and experimental results demonstrate that the proposed system scheme of employing the pneumatic drive and piezoelectric actuator can suppress the vibration and achieve the desired positioning location simultaneously. Furthermore, the adopted adaptive fuzzy control algorithms can significantly enhance the control performance.

  15. Fueling of magnetically confined plasmas by single- and two-stage repeating pneumatic pellet injectors

    SciTech Connect

    Gouge, M.J.; Combs, S.K.; Foust, C.R.; Milora, S.L.

    1990-01-01

    Advanced plasma fueling systems for magnetic fusion confinement experiments are under development at Oak Ridge National Laboratory (ORNL). The general approach is that of producing and accelerating frozen hydrogenic pellets to speeds in the kilometer-per-second range using single shot and repetitive pneumatic (light-gas gun) pellet injectors. The millimeter-to-centimeter size pellets enter the plasma and continuously ablate because of the plasma electron heat flux, depositing fuel atoms along the pellet trajectory. This fueling method allows direct fueling in the interior of the hot plasma and is more efficient than the alternative method of injecting room temperature fuel gas at the wall of the plasma vacuum chamber. Single-stage pneumatic injectors based on the light-gas gun concept have provided hydrogenic fuel pellets in the speed range of 1--2 km/s in single-shot injector designs. Repetition rates up to 5 Hz have been demonstrated in repetitive injector designs. Future fusion reactor-scale devices may need higher pellet velocities because of the larger plasma size and higher plasma temperatures. Repetitive two-stage pneumatic injectors are under development at ORNL to provide long-pulse plasma fueling in the 3--5 km/s speed range. Recently, a repeating, two-stage light-gas gun achieved repetitive operation at 1 Hz with speeds in the range of 2--3 km/s.

  16. Pneumatic retinopexy versus scleral buckle for repairing simple rhegmatogenous retinal detachments

    PubMed Central

    Hatef, Elham; Sena, Dayse F; Fallano, Katherine A; Crews, Jonathan; Do, Diana V

    2015-01-01

    Background Rhegmatogenous retinal detachment (RRD) is a full-thickness break in the sensory retina, caused by vitreous traction on the retina. While pneumatic retinopexy, scleral buckle, and vitrectomy are the accepted surgical interventions for eyes with RRD, their relative effectiveness has remained controversial. Objectives The objectives of this review were to assess the effectiveness and safety of pneumatic retinopexy versus scleral buckle or pneumatic retinopexy versus a combination treatment of scleral buckle and vitrectomy for people with RRD. The secondary objectives were to summarize any data on economic measures and quality of life. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to January 2015), EMBASE (January 1980 to January 2015), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to January 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 January 2015. Selection criteria We included all randomized or quasi-randomized controlled trials comparing the effectiveness of pneumatic retinopexy versus scleral buckle (with or without vitrectomy) for eyes with RRD. Data collection and analysis After screening for eligibility, two review authors independently extracted study characteristics, methods, and outcomes. We followed systematic review standards as set forth by The Cochrane Collaboration. Main results We included two randomized controlled trials (218 eyes of 216 participants) comparing the effectiveness of

  17. Evacuation of coal from hoppers/silos with low pressure pneumatic blasting systems

    NASA Technical Reports Server (NTRS)

    Fischer, J. S.

    1977-01-01

    The need for an efficient, economical, effective and quiet device for moving coal and other difficult bulk solids was recognized. Thus came the advent of the low pressure pneumatic blasting system - a very efficient means of using a small amount of plant air (up to 125 PSI) to eliminate the most troublesome material hang-ups in storage containers. This simple device has one moving part and uses approximately 3% of the air consumed by a pneumatic vibrator on the same job. The principle of operation is very simple: air stored in the unit's reservoir is expelled directly into the material via a patented quick release valve. The number, size, and placement of the blaster units on the storage vessel is determined by a series of tests to ascertain flowability of the problem material. These tests in conjunction with the hopper or silo configuration determine specification of a low pressure pneumatic blasting system. This concept has often proven effective in solving flow problems when all other means have failed.

  18. Morphing nacelle inlet lip with pneumatic actuators and a flexible nano composite sandwich panel

    NASA Astrophysics Data System (ADS)

    Gulsine Ozdemir, Nazli; Scarpa, Fabrizio; Craciun, Monica; Remillat, Chrystel; Lira, Cristian; Jagessur, Yogesh; Da Rocha-Schmidt, Luiz

    2015-12-01

    We present a hybrid pneumatic/flexible sandwich structure with thermoplastic (TP) nanocomposite skins to enable the morphing of a nacelle inlet lip. The design consists of pneumatic inflatables as actuators and a flexible sandwich panel that morphs under variable pressure combinations to adapt different flight conditions and save fuel. The sandwich panel forms the outer layer of the nacelle inlet lip. It is lightweight, compliant and impact resistant with no discontinuities, and consists of graphene-doped thermoplastic polyurethane (G/TPU) skins that are supported by an aluminium Flex-core honeycomb in the middle, with near zero in-plane Poisson’s ratio behaviour. A test rig for a reduced-scale demonstrator was designed and built to test the prototype of morphing nacelle with custom-made pneumatic actuators. The output force and the deflections of the experimental demonstrator are verified with the internal pressures of the actuators varying from 0 to 0.41 MPa. The results show the feasibility and promise of the hybrid inflatable/nanocomposite sandwich panel for morphing nacelle airframes.

  19. An Observer-Based Friction Compensation Technique for Positioning Control of a Pneumatic Servo System

    NASA Astrophysics Data System (ADS)

    Kosaki, Takahiro; Sano, Manabu

    This paper presents a technique to cope with undesirable frictional effects in positioning control of a pneumatic actuator. This technique is based on an observer for estimating the dynamically varying friction force on-line. The observer is derived from an available nonlinear observer for Coulomb friction by modifying it to fit the pneumatic actuator and to enhance its estimation ability. Our pneumatic servo system for positioning consists of an inner pressure control loop, an outer position control loop, the friction observer, and a velocity observer. In this system, the friction force is compensated by adjusting a desired pressure value sent from the outer loop to the inner loop according to the friction observer output. Experimental comparisons with a conventional control system using friction compensation by means of accelerometer information feedback were carried out and show that our system works with almost the same high positioning accuracy as the conventional system, despite having neither an accelerometer nor a velocity sensor, and is more advantageous from the perspective of cost performance.

  20. Continued Development and Application of Circulation Control Pneumatic Technology to Advanced Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.

    1998-01-01

    Personnel of the Georgia Tech Research Institute (GTRI) Aerospace and Transportation Lab have completed a four-year grant program to develop and evaluate the pneumatic aerodynamic technology known as Circulation Control (CC) or Circulation Control Wing (CCW) for advanced transport aircraft. This pneumatic technology, which employs low-level blowing from tangential slots over round or near-round trailing edges of airfoils, greatly augments the circulation around a lifting or control surface and thus enhances the aerodynamic forces and moments generated by that surface. Two-dimensional force augmentations as high as 80 times the input blowing momentum coefficient have been recorded experimentally for these blown devices, thus providing returns of 8000% on the jet momentum expended. A further benefit is the absence of moving parts such as mechanical flaps, slats, spoilers, ailerons, elevators and rudders from these pneumatic surfaces, or the use of only very small, simple, blown aerodynamic surfaces on synergistic designs which integrate the lift, drag and control surfaces. The application of these devices to advanced aircraft can offer significant benefits in their performance, efficiency, simplicity, reliability, economic cost of operation, noise reduction, and safety of flight. To further develop and evaluate this potential, this research effort was conducted by GTRI under grant for the NASA Langley Research Center, Applied Aerodynamics Division, Subsonic Aerodynamics Branch, between June 14, 1993 and May 31, 1997.

  1. Design and application of a gripper for microparts using flexure hinges and pneumatic actuation

    NASA Astrophysics Data System (ADS)

    Schlick, Jochen; Zuehlke, Detlef

    2001-10-01

    In this paper a new gripper for microparts with dimensions of 200 to 3500 micrometers is presented that is especially designed for industrial suitability. This covers beside repeatability of position and force robustness of the mechanical structure, simple interfaces of the gripper's control structure and long service life. The minimization of the grippers size and weight is no superior objective because today's precision robots usually have sufficient payload and working space. To achieve this goal well tested technology from micro- an macro handling devices are combined. The new gripper is made up of a symmetrical guiding mechanism based on flexure hinges of aluminum and it is driven by a pneumatic actuator. In the first step the maximal gripping force can easily be limited by the working pressure of the pneumatic actuator. Standard open/ close commands provide a robust control interface. The technology of pneumatic actuation is well known and reliable. Since minimization of size is not the primary goal, a long service life can be achieved by limiting the mechanical stress in the flexure hinges. A skirt of aluminum protects the guiding device against destruction caused by collisions. The new gripper has been realized and has been used in a microassembly station where it proved its reliability and robustness in thousands of gripping cycles thus demonstrating its industrial suitability. An experimental evaluation was carried out in order to assess the properties of the gripper.

  2. The self-generated peristaltic motion of cascaded pneumatic actuators for micro pumps

    NASA Astrophysics Data System (ADS)

    Jeong, Ok Chan; Konishi, Satoshi

    2008-08-01

    This paper presents a new actuation mechanism for the self-generated peristaltic motion of cascaded actuators and its application to micro pumps. The operational method is based on the fluidic circuit of an elastic tube. The elastic tube is modeled as a ladder network consisting of fluidic resistances in series and fluidic capacitances in parallel like multi-stage low-pass filters in an electrical circuit. All segments of the lumped model of the elastic tube have different dynamic characteristics because their time constants are different. In other words, all segments should be deformed sequentially like peristaltic motion. This phenomenon has good potential to cause peristaltic motion of the cascaded actuators in response to the application of single-phase pneumatic signals. Analogues between the electrical and fluidic circuits were applied to a pneumatic micro pump with a micro fluidic channel and three pneumatic actuators connecting a unique micro channel for supplying the compressed air. The polymeric micro pumps were fabricated with soft lithography using only polyimethylsiloxsane. The proposed working principle was verified through simulation of the static deformation of the cascaded actuator diaphragms and the actuator, as well as tested experimentally. The dual operational modes of the proposed device (i.e., rubber-seal valve and peristaltic pumping mode) were also verified and successfully demonstrated in a liquid pumping test of the single and double pumps.

  3. Ex vivo investigations of laser auricular cartilage reshaping with carbon dioxide spray cooling in a rabbit model

    PubMed Central

    Wu, Edward C.; Sun, Victor; Manuel, Cyrus T.; Protsenko, Dmitriy E.; Jia, Wangcun; Nelson, J. Stuart; Wong, Brian J. F.

    2014-01-01

    Laser cartilage reshaping (LCR) with cryogen spray cooling is a promising modality for producing cartilage shape change while reducing cutaneous thermal injury. However, LCR in thicker tissues, such as auricular cartilage, requires higher laser power, thus increasing cooling requirements. To eliminate the risks of freeze injury characteristic of high cryogen spray pulse rates, a carbon dioxide (CO2) spray, which evaporates rapidly from the skin, has been proposed as the cooling medium. This study aims to identify parameter sets which produce clinically significant reshaping while producing minimal skin thermal injury in LCR with CO2 spray cooling in ex vivo rabbit auricular cartilage. Excised whole rabbit ears were mechanically deformed around a cylindrical jig and irradiated with a 1.45-μm wavelength diode laser (fluence 12–14 J/cm2 per pulse, four to six pulse cycles per irradiation site, five to six irradiation sites per row for four rows on each sample) with concomitant application of CO2 spray (pulse duration 33–85 ms) to the skin surface. Bend angle measurements were performed before and after irradiation, and the change quantified. Surface temperature distributions were measured during irradiation/cooling. Maximum skin surface temperature ranged between 49.0 to 97.6 °C following four heating/cooling cycles. Significant reshaping was achieved with all laser dosimetry values with a 50–70 °C difference noted between controls (no cooling) and irradiated ears. Increasing cooling pulse duration yielded progressively improved gross skin protection during irradiation. CO2 spray cooling may potentially serve as an alternative to traditional cryogen spray cooling in LCR and may be the preferred cooling medium for thicker tissues. Future studies evaluating preclinical efficacy in an in vivo rabbit model are in progress. PMID:23307439

  4. Meniscal allograft transplantation in rabbit.

    PubMed

    Vilela, Liana M; Del Carlo, Ricardo J; Melo Filho, Edson V; Favarato, Lukiya S C; Duarte, Tatiana S; Pontes, Kelly C S; Cunha, Daise N Q

    2015-01-01

    This study evaluated the technique for meniscal allograft transplantation using allografts preserved in glycerin 98% in rabbits. Euthanasia was performed at 70 days to compare the transplanted (TM1 to TM16) versus the contralateral meniscus (OM1 to OM16). Sixteen menisci, 8 transplanted and 8 contralateral, were submitted to gross examination, histomorphometric analysis for identification and quantification of cellular type, and for quantification and distribution of collagen fibers. A revascularization study was conducted in all of the other samples. Lengths of the OM varied from 0.9 to 1.0 cm and two TM were smaller. All TM were completely attached to the synovial membrane, except for one case that presented partial fixation. Both, TM and OM had similar amounts of chondrocytes, fibroblasts and fibrocytes, and at the horns, chondrocytes were predominant. The collagen fibers in TM were well organized throughout the body, and disorganized at the horns. These fibers in OM were organized. The amounts of collagen type I and III, and the vascularization of the perimeniscal tissue and of the edge were similar in OM and TM. These results demonstrated graft integration and thus this transplantation technique and preservation method may be recommended. PMID:26648544

  5. Phosphatidylinositol kinase from rabbit reticulocytes

    SciTech Connect

    Tuazon, P.T.; Heng, A.B.W.; Traugh, J.A.

    1986-05-01

    Phosphatidylinositol (PI) kinase was isolated from the postribosomal supernatant of rabbit reticulocytes. This activity was identified by the formation of a product that comigrated with phosphatidylinositol-4-phosphate (PIP) when purified PI was phosphorylated in the presence of (/sup 32/P)ATP and Mg/sup 2 +/. Three major peaks of PI kinase activity were resolved by chromatography on DEAE-cellulose. The first peak eluted at 50-100 mM NaCl together with several serine protein kinases, casein kinase (CK) I and protease activated kinase (PAK) I and II. The PI kinase was subsequently separated from the protein kinases by chromatography on phosphocellulose. The second peak eluted at 125-160 mM NaCl and contained another lipid kinase activity that produced a product which comigrated with phosphatidic acid on thin layer chromatography. The third peak, which eluted at 165-200 mM NaCl, partly comigrated with casein kinase (CK) II and an active protein kinase(s) which phosphorylated mixed histone and histone I. CK II and the histone kinase activities were also separated by chromatography on phosphocelluslose. The different forms of PI kinase were characterized and compared with respect to substrate and salt requirements.

  6. Ultrastructure of rabbit semilunar cartilages.

    PubMed Central

    Ghadially, F N; Thomas, I; Yong, N; Lalonde, J M

    1978-01-01

    A light and transmission electron microscopical study of 6 to 8 months old rabbit semilunar cartilages has shown that the cells in this tissue resemble chondrocytes more than fibroblasts. The prominent organelles in these cells were rough endoplasmic reticulum and the Golgi complex. An unusual finding was the occurrence of filamentous material in Golgi sacs and vesicles, and collagen fibrils within smooth membrane-bound tubular structures, apparently within the cells. Collagen fibrils forming fibres, fibre bundles and lamellae constituted the major component of the menisci. Protein-polysaccharide particles and associated fine filaments were found in the interfibrillary matrix and in the sparse territorial matrix adjacent to the chondrocytes. Numerous immature elastic fibrils, and rare mature elastic fibres with an electorn-lucent amorphous core, were also found in the general matrix amongst the collagen fibrils. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 PMID:580431

  7. Immunobiological effect of bitemporal exposure of rabbits to microwaves

    SciTech Connect

    Bogolyubov, V.M.; Pershin, S.B.; Frenkel', I.D.; Sidorov, V.D.; Galenchik, A.I.; Ponomarev, Yu.T.; Bobkova, A.S.; Kuz'min, S.N.; Moshiashvili, I.Ya.; Kozlova, N.N.; Korovkina, E.G.; Agibalov, Yu.V.

    1987-01-01

    The authors investigate the effects of microwave radiation on the immunological behavior of the thyroid and various hormones of rabbits. Irradiation was carried out on the heads of the animals. They were then divided into four groups depending on the period of exposure. The number of hemolysis-forming cells against sheep red blood cells and the concentration of serum immunoglobulins were determined. Levels of TSH, triiodothyronine, thyroxine, testosterone and prostaglandins in serum or blood plasma were determined by radioimmunoassay and the concentration of total 11-hydroxycorticosteroids in the adrenals and plasma were determined by fluorimetry. Microwave radiation of the temporo-parietal region of the head was found to decrease the number of background hemolysis-forming cells. An increase in glucocorticoid function was recorded. Thyroid function was depressed. The plasma 11-hydroxycorticosteroid level was significantly raised. It is concluded in general that microwave irradiation leads to activation of the hypothalamo-hypophyseo-adrenal system with consequent enhancement of the glucocorticoid function of the adrenal cortex and depression of thyroid function.

  8. Heavy charged-particle induced lesions in rabbit cerebral cortex

    SciTech Connect

    Woodruff, K.H.; Lyman, J.T.; Fabrikant, J.I.

    1988-02-01

    Fourteen male rabbits received single doses of 20, 40, and 80 Gy of neon irradiation with an extended Bragg peak. They were sacrificed at 1 day, 1 week, and 6 months post-irradiation. The tissue changes which showed a significant time-dose relationship were leakage of carbon particles from blood vessels, focal arachnoiditis, hemorrhage, cystic necrosis, and a total histopathologic score using a point system of grading. The focal nature of the lesions was clearly demonstrated with 2 mm thick macrotome sections. The transition zone between damaged brain and microscopically normal appearing brain was less than 1 mm and the tissue damage induced was morphologically similar to that of other radiation modalities. These findings may have important therapeutic implications for patients. The sharply demarcated boundaries of heavy charged-particle induced lesions suggest these beams will be useful for obliterating tissue in areas where it is critical that a transition from undamaged to severely damaged tissue must occur over a short distance, such as in the central nervous system.

  9. Simple suture and anchor in rabbit hips

    PubMed Central

    Garcia Filho, Fernando Cal; Guarniero, Roberto; de Godoy Júnior, Rui Maciel; Pereira, César Augusto Martins; Matos, Marcos Almeida; Garcia, Lucas Cortizo

    2012-01-01

    Objective Using biomechanical studies, this research aims to compare hip capsulorrhaphy in rabbits, carried out with two different techniques: capsulorrhaphy with simple sutures and with anchors. Method Thirteen New Zealand Albino (Oryctolaguscuniculus) male rabbits, twenty-six hip joints, were used. First, a pilot project was performed with three rabbits (six hip joints). This experiment consisted of ten rabbits divided into two groups: group 1 underwent capsulorrhaphy on both right and left hips with simple suture using polyglycolic acid absorbable thread, and group 2 underwent capsulorrhaphy with titanium anchors. After a four-week postoperative period, the animals were euthanized and the hip joints were frozen. On the same day of the biomechanical studies, after the hip joints were previously unfrozen, the following parameters were evaluated: rigidity, maximum force, maximum deformity and energy. Results There was no relevant statistical difference in rigidity, maximum force, maximum deformity and energy between the simple suture and anchor groups. Conclusion Through biomechanical analyses, using parameters of rigidity, maximum force, maximum deformity and energy, it has been shown that capsulorrhaphy with simple suture and with anchors has similar results in rabbit hip joints. Level of Evidence II, Prospective Comparative Study. PMID:24453618

  10. Hypercholesterolemia Impaired Sperm Functionality in Rabbits

    PubMed Central

    Monclus, Maria A.; Cabrillana, Maria E.; Clementi, Marisa A.; Espínola, Leandro S.; Cid Barría, Jose L.; Vincenti, Amanda E.; Santi, Analia G.; Fornés, Miguel W.

    2010-01-01

    Hypercholesterolemia represents a high risk factor for frequent diseases and it has also been associated with poor semen quality that may lead to male infertility. The aim of this study was to analyze semen and sperm function in diet-induced hypercholesterolemic rabbits. Twelve adult White New Zealand male rabbits were fed ad libitum a control diet or a diet supplemented with 0.05% cholesterol. Rabbits under cholesterol-enriched diet significantly increased total cholesterol level in the serum. Semen examination revealed a significant reduction in semen volume and sperm motility in hypercholesterolemic rabbits (HCR). Sperm cell morphology was seriously affected, displaying primarily a “folded head”-head fold along the major axe-, and the presence of cytoplasmic droplet on sperm flagellum. Cholesterol was particularly increased in acrosomal region when detected by filipin probe. The rise in cholesterol concentration in sperm cells was determined quantitatively by Gas chromatographic-mass spectrometric analyses. We also found a reduction of protein tyrosine phosphorylation in sperm incubated under capacitating conditions from HCR. Interestingly, the addition of Protein Kinase A pathway activators -dibutyryl-cyclic AMP and iso-butylmethylxanthine- to the medium restored sperm capacitation. Finally, it was also reported a significant decrease in the percentage of reacted sperm in the presence of progesterone. In conclusion, our data showed that diet-induced hypercholesterolemia adversely affects semen quality and sperm motility, capacitation and acrosomal reaction in rabbits; probably due to an increase in cellular cholesterol content that alters membrane related events. PMID:20976152

  11. Accumulation of sup 125 I-factor XI in atheroma of rabbit with hereditary hyperlipidemia (WHHL-rabbit)

    SciTech Connect

    Komiyama, Y.; Masuda, M.; Murakami, T.; Nishikado, H.; Egawa, H.; Nishimura, T.; Morii, S.; Murata, K. )

    1989-10-01

    We have studied the turnover and accumulation of rabbit factor XI (F.XI) in atherosclerotic lesion in Watanabe-hereditable hyperlipidemic rabbit (WHHL rabbit) to reveal the participation of blood coagulation in atherosclerotic lesion. Rabbit F.XI was iodinated and administered intravenously to WHHL rabbits and Japanese white rabbits. The turnover of {sup 125}I-rabbit F.XI was significantly faster in WHHL rabbits (T1/2 = 2.84 +/- 0.44 days) than in normal rabbits (T1/2 = 4.44 +/- 0.42 days). The thoracic aorta of WHHL rabbit was strongly labelled with {sup 125}I-rabbit F.XI, in sections obtained after 5 days by en-face autoradiography, whereas no radioactivity was detected in normal aorta. By an immunohistochemical study of WHHL rabbit aorta, we confirmed that many F.XI- and fibrin-related compounds existed in the atheroma, whereas albumin did not in these area. These results suggest that the activation of F.XI proceeds on the atherosclerotic lesions of WHHL rabbits.

  12. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... shall be dealt with in one of the following ways: (a) If it is determined by a veterinary inspector that... veterinary inspector that further handling of the rabbits will not create a health hazard, such rabbits...

  13. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... shall be dealt with in one of the following ways: (a) If it is determined by a veterinary inspector that... veterinary inspector that further handling of the rabbits will not create a health hazard, such rabbits...

  14. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... shall be dealt with in one of the following ways: (a) If it is determined by a veterinary inspector that... veterinary inspector that further handling of the rabbits will not create a health hazard, such rabbits...

  15. Damage to the photoreceptor cells of the rabbit retina from 56Fe ions: effect of age at exposure, 1

    NASA Technical Reports Server (NTRS)

    Williams, G. R.; Lett, J. T.; Chatterjee, A. (Principal Investigator)

    1996-01-01

    Optic and proximate tissues of New Zealand white (NZW) rabbits at ages (approximately 3.5 years) near the middle of their median lifespan (5-7 years) were given 0.5-3.5 Gy of 465 MeV u-1 56Fe ions in the Bragg plateau region of energy deposition at a linear energy transfer (LET infinity) of 220 +/- 31 keV micrometer-1. Dose-dependent losses of retinal photoreceptor cells (rods) occurred until 1-2 years after irradiation, the period of this interim report. Similar cumulative losses of photoreceptor cells were seen during the period 1-2 years post-irradiation for rabbits given comparable exposures when young (6-9 weeks old). Since losses of photoreceptor cells at early times had not been determined previously, the current experiment, which was designed to simulate the responses of mature astronauts, redressed that deficiency.

  16. Hemostatic Function, Survival, and Membrane Glycoprotein Changes in Young versus Old Rabbit Platelets

    PubMed Central

    Blajchman, Morris A.; Senyi, Andrew F.; Hirsh, Jack; Genton, Edward; George, James N.

    1981-01-01

    Although in vitro studies have demonstrated functional differences between young and old platelets, in vivo differences have not been precisely established. Therefore the in vivo hemostatic function of young and old platelets and the survival time have been examined in rabbits. The hemostatic function was measured by performing serial ear bleeding times in irradiation-induced thrombocytopenic rabbits. After irradiation with 930 rad the platelet count gradually diminished reaching a nadir (∼20 × 103/μl) at 10 d. The platelets present in the circulation, 7-10 d after irradiation, were considered old platelets, and the platelets present after recovery, 11-14 d postirradiation, young platelets. The measurement of platelet size was consistent with the hypothesis that platelets become smaller with age: the mean size was 3.84 μm3 for old platelets and 5.86 μm3 for young platelets. Regression analysis of the relationship between the bleeding time and the platelet count in 18 rabbits showed a significantly different slope for rabbits with predominantly old platelets compared with rabbits with predominantly young platelets (P < 0.001). Young platelets were more effective giving much shorter bleeding times than old platelets at comparable platelet counts. Survival times of young and old platelets were measured using platelets harvested on day 8 postirradiation (old platelets) and day 12 postirradiation (young platelets) that were labeled and then reinjected into normal recipient animals. The mean platelet survival time, calculated by gamma function, of old platelets was 28.8 h; of young platelets, 87.4 h; and of normally circulating heterogeneous platelets, (normal platelets) 53.0 h. Notably, the survival of old platelets was found to be exponential, and of young platelets, linear. Analysis of the membrane glycoproteins in young, old and normal platelets indicated that there was no qualitative difference amongst the young, normal, and old platelets. The relative

  17. In Vivo Laser Cartilage Reshaping with Carbon Dioxide Spray Cooling in a Rabbit Ear Model: A Pilot Study

    PubMed Central

    Kuan, Edward C.; Hamamoto, Ashley A.; Sun, Victor; Nguyen, Tony; Manuel, Cyrus T.; Protsenko, Dmitry E.; Wong, Brian J.F.; Nelson, J. Stuart; Jia, Wangcun

    2014-01-01

    BACKGROUND/OBJECTIVES Similar to conventional cryogen spray cooling, carbon dioxide (CO2) spray may be used in combination with laser cartilage reshaping (LCR) to produce cartilage shape change while minimizing cutaneous thermal injury. Recent ex vivo evaluation of LCR with CO2 cooling in a rabbit model has identified a promising initial parameter space for in vivo safety and efficacy evaluation. This pilot study aimed to evaluate shape change and cutaneous injury following LCR with CO2 cooling in 5 live rabbits. STUDY DESIGN/MATERIALS AND METHODS The midportion of live rabbit ears were irradiated with a 1.45 μm wavelength diode laser (12 J/cm2) with simultaneous CO2 spray cooling (85 ms duration, 4 alternating heating/cooling cycles per site, 5 to 6 irradiation sites per row for 3 rows per ear). Experimental and control ears (no LCR) were splinted in the flexed position for 30 days following exposure. A total of 5 ears each were allocated to the experimental and control groups. RESULTS Shape change was observed in all irradiated ears (mean 70 ± 3°), which was statistically different from control (mean 37 ± 11 °, p = 0.009). No significant thermal cutaneous injury was observed, with preservation of the full thickness of skin, microvasculature, and adnexal structures. Confocal microscopy and histology demonstrated an intact and viable chondrocyte population surrounding irradiated sites. CONCLUSIONS LCR with CO2 spray cooling can produce clinically significant shape change in the rabbit auricle while minimizing thermal cutaneous and cartilaginous injury and frostbite. This pilot study lends support for the potential use of CO2 spray as an adjunct to existing thermal-based cartilage reshaping modalities. An in vivo systematic evaluation of optimal laser dosimetry and cooling parameters is required. PMID:25557008

  18. White Rabbit in space related application

    NASA Astrophysics Data System (ADS)

    JamroŻy, M.; Gumiński, M.; Kasprowicz, G.; Romaniuk, R.; Poźniak, K.

    2015-09-01

    This paper describes study results regarding potential use of White Rabbit technology in Space Related Applications. During the study Technology Readiness Level and Compliance with Space Related Applications was evaluated. After considering possible deployment and development scenarios, main focus has been put on European Space Agency's tracking station system. This outcome derived from specific requirements of tracking system which are coherent with White Rabbit technology scope of application and further development plans. Current state of Time and Frequency Distribution technology implemented into tracking stations is based on multiple different technologies coexisting in parallel creating a complex system. It requires specific, custom made hardware to combine all the technologies which makes it expensive and difficult to maintain. White Rabbit could be use to reduce Time and Frequency Distribution to a single Ethernet based network with link redundancy, payload data transfer and sub-nanosecond accuracy.

  19. Light stimulation of iris tyrosinase in vivo. [Rabbits

    SciTech Connect

    Dryja, T.P.; Kimball, G.P.; Albert, D.M.

    1980-05-01

    This paper presents evidence that light stimulates tyrosinase activity in iris melanocytes in rabbits. Levels of iris tyrosinase were found to be greater in eyes of rabbits exposed to light for 6 weeks than in eyes of rabbits maintained in darkness. Despite increasing tyrosinase levels, exposure to light produced no clinically observable change in iris color.

  20. General intravenous anesthesia for brachial plexus surgery in the rabbit.

    PubMed

    Reichert, P; Rutowski, R; Kielbowicz, Z; Kuryszko, J; Kielbowicz, M

    2013-01-01

    The rabbit is a good experimental model for brachial plexus surgery. The risks of death during anesthesia were significantly greater in rabbits than cats or dogs. This article presents the protocol of injectable anesthesia for a short surgical procedure, safe for the rabbit patient and convenient for the surgeon. PMID:24597314

  1. Comparative quantitative monitoring of rabbit haemorrhagic disease viruses in rabbit kittens

    PubMed Central

    2014-01-01

    Background Only one strain (the Czech CAPM-v351) of rabbit haemorrhagic disease virus (RHDV) has been released in Australia and New Zealand to control pest populations of the European rabbit O. cuniculus. Antigenic variants of RHDV known as RHDVa strains are reportedly replacing RHDV strains in other parts of the world, and Australia is currently investigating the usefulness of RHDVa to complement rabbit biocontrol efforts in Australia and New Zealand. RHDV efficiently kills adult rabbits but not rabbit kittens, which are more resistant to RHD the younger they are and which may carry the virus without signs of disease for prolonged periods. These different infection patterns in young rabbits may significantly influence RHDV epidemiology in the field and hence attempts to control rabbit numbers. Methods We quantified RHDV replication and shedding in 4–5 week old rabbits using quantitative real time PCR to assess their potential to shape RHDV epidemiology by shedding and transmitting virus. We further compared RHDV-v351 with an antigenic variant strain of RHDVa in kittens that is currently being considered as a potential RHDV strain for future release to improve rabbit biocontrol in Australia. Results Kittens were susceptible to infection with virus doses as low as 10 ID50. Virus growth, shedding and transmission after RHDVa infection was found to be comparable or non-significantly lower compared to RHDV. Virus replication and shedding was observed in all kittens infected, but was low in comparison to adult rabbits. Both viruses were shed and transmitted to bystander rabbits. While blood titres indicated that 4–5 week old kittens mostly clear the infection even in the absence of maternal antibodies, virus titres in liver, spleen and mesenteric lymph node were still high on day 5 post infection. Conclusions Rabbit kittens are susceptible to infection with very low doses of RHDV, and can transmit virus before they seroconvert. They may therefore play an important

  2. Nitrosylation of rabbit ferrous heme-hemopexin.

    PubMed

    Fasano, Mauro; Bocedi, Alessio; Mattu, Marco; Coletta, Massimo; Ascenzi, Paolo

    2004-10-01

    Hemopexin (HPX) serves as a trap for toxic plasma heme, ensuring its complete clearance by transportation to the liver. Moreover, HPX-heme has been postulated to play a key role in the homeostasis of nitric oxide (NO). Here, the thermodynamics for NO binding to rabbit ferrous HPX-heme as well as the EPR and optical absorption spectroscopic properties of rabbit ferrous nitrosylated HPX-heme (HPX-heme-NO) are reported. The value of the dissociation equilibrium constant for NO binding to rabbit ferrous HPX-heme (i.e., H) is (1.4+/-0.2)x10(-7) M, at pH 7.0 and 10.0 degrees C; the value of H is unaffected by sodium chloride. At pH 7.0, rabbit ferrous HPX-heme-NO is a six-coordinate heme-iron species, characterized by an X-band EPR spectrum with an axial geometry and by epsilon=146 mM(-1) cm(-1) at 419 nm. At pH 4.0, rabbit ferrous HPX-heme-NO is a five-coordinate heme-iron species, characterized by an X-band EPR spectrum with three-line splitting centered at 334 mT and by epsilon=74 mM(-1) cm(-1) at 387 nm. The p K(a) value of the reversible pH-induced six- to five-coordinate spectroscopic transition is 4.8+/-0.1 in the absence of sodium chloride and 4.3+/-0.1 in the presence of 1.5x10(-1) M sodium chloride. This result is in agreement with the effect of sodium chloride on rabbit HPX-heme stability. The present data have been analyzed in parallel with those of a related heme model compound and heme-protein systems. PMID:15378409

  3. Control of transient vibrations due to stage movements in 6-dof active pneumatic table by inertial force compensation

    NASA Astrophysics Data System (ADS)

    Sun, Jong-Oh; Kim, Kwang-joon

    2013-10-01

    Passive pneumatic tables are popularly used in precision measurements or processes for isolation of ground vibrations over frequency ranges higher than resonance frequencies of a few Hz typically. Recently, active pneumatic tables are also used often because the passive systems are liable to table excitations in the low resonance frequency ranges, causing long settling times. In studies on the active tables, disturbances onto the tables were often regarded to be unknown and, hence, feedback control algorithms were implemented. However, the disturbances are mostly due to inertial forces due to movement of equipment on the table, e.g., x-y stages. Such a movement is given relative to the table as command inputs. Since absolute motion of the table is normally measured in an active isolation table, absolute motion of the equipment can be easily estimated for calculation of the inertial force exerted onto the table by the moving equipment. Consequently, by compensating dynamic pressure inside the pneumatic chamber to counteract with the inertia force due to the equipment motion, resultant forces acting onto the table can be made zero. In this paper, how to apply the proposed feed-forward control algorithm to a 6-degree of freedom active pneumatic table with time-delay pneumatic control is presented. Performance of the inertial force compensation control evaluated through experiments is also discussed.

  4. Chromate reduction by rabbit liver aldehyde oxidase

    SciTech Connect

    Banks, R.B.; Cooke, R.T. Jr.

    1986-05-29

    Chromate was reduced during the oxidation of 1-methylnicotinamide chlorine by partially purified rabbit liver aldehyde oxidase. In addition to l-methylnicotinamide, several other electron donor substrates for aldehyde oxidase were able to support the enzymatic chromate reduction. The reduction required the presence of both enzyme and the electron donor substrate. The rate of the chromate reduction was retarded by inhibitors or aldehyde oxidase but was not affected by substrates or inhibitors of xanthine oxidase. These results are consistent with the involvement of aldehyde oxidase in the reduction of chromate by rabbit liver cytosolic enzyme preparations.

  5. Computer simulation of the pneumatic separator in the pneumatic-electrostatic separation system for recycling waste printed circuit boards with electronic components.

    PubMed

    Xue, Mianqiang; Xu, Zhenming

    2013-05-01

    Technologies could be integrated in different ways into automatic recycling lines for a certain kind of electronic waste according to practical requirements. In this study, a new kind of pneumatic separator with openings at the dust hooper was applied combing with electrostatic separation for recycling waste printed circuit boards. However, the flow pattern and the particles' movement behavior could not be obtained by experimental methods. To better control the separation quantity and the material size distribution, computational fluid dynamics was used to model the new pneumatic separator giving a detailed understanding of the mechanisms. Simulated results showed that the tangential velocity direction reversed with a relatively small value. Axial velocity exhibited two sharp decreases at the x axis. It is indicated that the bottom openings at the dust hopper resulted in an enormous change in the velocity profile. A new phenomenon that was named dusting was observed, which would mitigate the effect of particles with small diameter on the following electrostatic separation and avoid materials plugging caused by the waste printed circuit boards special properties effectively. The trapped materials were divided into seven grades. Experimental results showed that the mass fraction of grade 5, grade 6, and grade 7 materials were 27.54%, 15.23%, and 17.38%, respectively. Grade 1 particles' mass fraction was reduced by 80.30% compared with a traditional separator. Furthermore, the monocrystalline silicon content in silicon element in particles with a diameter of -0.091 mm was 18.9%, higher than that in the mixed materials. This study could serve as guidance for the future material flow control, automation control, waste recycling, and semiconductor storage medium destruction. PMID:23560940

  6. In vitro CD4+ lymphocyte transformation and infection in a rabbit model with a molecular clone of human T-cell lymphotrophic virus type 1.

    PubMed Central

    Collins, N D; Newbound, G C; Ratner, L; Lairmore, M D

    1996-01-01

    We transfected human and rabbit peripheral blood mononuclear cells (PBMC) with the ACH molecular clone of human T-cell lymphotropic virus type 1 (HTLV-1) to study its in vitro and in vivo properties. PBMC transfected with ACH were shown to transfer infection to naive PBMC. ACH transformed rabbit PBMC, as indicated by interleukin-2-independent proliferation of a transfectant culture. This transformant culture was shown by flow cytometric analysis to be a CD4+ CD25+ T-lymphocyte population containing, as determined by Southern blot analysis, at least three integrated HTLV-1 proviral copies. HTLV-1 infection was produced in rabbits inoculated with ACH-transfected, irradiated PBMC. Inoculated rabbits seroconverted to positivity for antibodies against HTLV-1 and had steady or rising HTLV-1 enzyme-linked immunosorbent assay antibody titers. Western blot (immunoblot) analysis revealed sustained seroconversion of rabbits to positivity for antibodies against all major viral antigenic determinants. Infection of rabbits was further demonstrated by antigen capture assay of p24 in PBMC and lymph node cultures and PCR amplification of proviral sequences from PBMC. These data suggest that ACH, like wild-type HTLV-1, infects and transforms primary CD4+ T lymphocytes and is infectious in vivo. This clone will facilitate investigations into the role of viral genes on biological properties of HTLV-1 in vitro and in vivo. PMID:8794375

  7. Cloning, Characteristics, and Functional Analysis of Rabbit NADPH Oxidase 5

    PubMed Central

    Chen, Feng; Yin, Caiyong; Dimitropoulou, Christiana; Fulton, David J. R.

    2016-01-01

    Background: Nox5 was the last member of the Nox enzyme family to be identified. Functionally distinct from the other Nox isoforms, our understanding of its physiological significance has been hampered by the absence of Nox5 in mouse and rat genomes. Nox5 is present in the genomes of other species such as the rabbit that have broad utility as models of cardiovascular disease. However, the mRNA sequence, characteristics, and functional analysis of rabbit Nox5 has not been fully defined and were the goals of the current study. Methods: Rabbit Nox5 was amplified from rabbit tissue, cloned, and sequenced. COS-7 cells were employed for expression and functional analysis via Western blotting and measurements of superoxide. We designed and synthesized miRNAs selectively targeting rabbit Nox5. The nucleotide and amino acid sequences of rabbit Nox5 were aligned with those of putative rabbit isoforms (X1, X2, X3, and X4). A phylogenetic tree was generated based on the mRNA sequence for Nox5 from rabbit and other species. Results: Sequence alignment revealed that the identified rabbit Nox5 was highly conserved with the predicted sequence of rabbit Nox5. Cell based experiments reveal that rabbit Nox5 was robustly expressed and produced superoxide at rest and in a calcium and PMA-dependent manner that was susceptible to superoxide dismutase and the flavoprotein inhibitor, DPI. miRNA-1 was shown to be most effective in down-regulating the expression of rabbit Nox5. Phylogenetic analysis revealed a close relationship between rabbit and armadillo Nox5. Rabbit Nox5 was relatively closely related to human Nox5, but lies in a distinct cluster. Conclusion: Our study establishes the suitability of the rabbit as a model organism to further our understanding of the role of Nox5 in cardiovascular and other diseases and provides new information on the genetic relationship of Nox5 genes in different species. PMID:27486403

  8. Possible interaction between myxomatosis and calicivirosis related to rabbit haemorrhagic disease affecting the European rabbit.

    PubMed

    Marchandeau, S; Bertagnoli, S; Peralta, B; Boucraut-Baralon, C; Letty, J; Reitz, F

    2004-11-01

    Serological data on myxoma virus, rabbit haemorrhagic disease (RHD) virus and RHD-like viruses in juvenile rabbits (Oryctolagus cuniculus) trapped in 1995, 1996 and 1997 in two areas of France were analysed. For each disease, the effects of bodyweight, year, month and seropositivity for the other disease were modelled by using logistic regressions. In one area, a model including RHD seropositivity was selected to explain the myxoma virus seropositivity. Models including myxoma virus seropositivity were selected to explain the RHD seropositivity in both areas, and the odds of a rabbit being seropositive to both viruses were 5.1 and 8.4 times higher than the odds of a rabbit being seronegative to myxoma virus and seropositive to RHD. The year and bodyweight had significant effects for myxomatosis in one area and for RHD in both areas. PMID:15573951

  9. Characterization and prediction of subsurface pneumatic response at Yucca Mountain, Nevada

    NASA Astrophysics Data System (ADS)

    Ahlers, C. Fredrik; Finsterle, Stefan; Bodvarsson, Gudmundur S.

    1999-05-01

    Yucca Mountain, Nevada is being investigated as the proposed site for geologic disposal of the United States' high level nuclear waste. A massive effort to collect data for characterization of the thermo-hydrologic behavior of the unsaturated zone is being conducted at the site. Several boreholes have been instrumented by the United States Geological Survey and the Nye County Nuclear Waste Repository Project Office for passive pneumatic monitoring of the subsurface. One-, two- and three-dimensional numerical models are used to simulate the observed subsurface pressure variations. The data are inverted using these models in order to characterize the unsaturated system and estimate the pneumatic diffusivity of important geologic features. Blind predictions of subsurface response and subsequent comparison to recorded data have built confidence in the models of Yucca Mountain. Inversions show that the pneumatic response of the system is dominated by the Paintbrush non-welded unit (PTn). Faults are shown to be fast pathways for gas flow but affect subsurface response only on a relatively local scale. Estimates of the diffusivity of the tuffs that comprise Yucca Mountain range from a low of 0.008 m 2/s in the non-welded pre-Yucca bedded tuff layer to a high of 4 m 2/s in the densely welded, fractured Topopah Spring tuff. Estimates of diffusivity in fault zones at Yucca Mountain range between 0.03 m 2/s and 1500 m 2/s with the highest being in the Drill Hole Wash fault where it intersects the Topopah Spring tuff.

  10. The use of pneumatically generated water pressure signals for aquifer characterization

    NASA Astrophysics Data System (ADS)

    Fort, M.; Roberts, R.; Chace, D.

    2013-12-01

    The use of pneumatically generated pressure signals for aquifer characterization Hydraulic tests are the most reliable method of obtaining estimates of hydrologic properties, such as conductivity, that are essential for flow and transport modeling. The use of a sinusoidal signal for hydraulic testing is well established, with Streltsova (1988), Rasmussen (2003) and others having developed analytic solutions. Sinusoidal tests provide a unique easily distinguished signal that reduces ambiguity during analysis and we show that a sinusoidal pressure signal propagates farther into the formation than a standard slug-test signal. If a sinusoidal test is combined with a slug and/or a constant rate test, it can further reduce uncertainty in the estimated parameter values. We demonstrate how pneumatic pressure can be used to generate all three of these signals. By positioning pressure transducers both below the water level and in the head space above the water, we can monitor the total pressure acting on the formation and the changes in water level. From the changes in water level, it is possible to calculate the flow rate in and out of the well, assuming that the well diameter and water density are known. Using gas flow controllers with a Supervisory Control And Data Acquisition (SCADA) system we are able to precisely control the pressures in the well. The use of pneumatic pressure has the advantage that it requires less equipment (no pumps) and produces no water. We also show how the numerical well test analysis program nSIGHTS can be used to analyze all three types of tests simultaneously and to assess the relative contribution of each type of test to the parameter estimation. nSIGHTS was recently released as open source by Sandia National Laboratories and is available for free.

  11. Comparison of high-resolution wax-embedded and pneumatically coupled borehole seismic detectors

    SciTech Connect

    Owen, T.E.; Parra, J.O. )

    1993-01-01

    High quality seismic measurements at frequencies up to about 2,000 Hz are needed if projected resolution limits on the order of 1m in spatial dimension are to be realized in reservoir structure delineation, cross-well sonic logging, and shallow reverse VSP applications. While sources and detectors are critical to this goal, the authors have investigated detector requirements in an objective way to demonstrate a successful design philosophy capable of achieving unprecedented wide-band frequency response and data quality in three-component shallow-borehole sensors. Two prototype detectors were developed: a nearly ideal responding wax-embedded reference'' detector and a pneumatically coupled detector exhibiting closely comparable performance. Their approach uses a three-axis accelerometer sensor assembly installed in a borehole drilled through the weathered surface to a depth at which the ground is competent enough to support practical kilohertz wave propagation. The wax-coupled detector is planted using a meltable wax embedment to achieve a rigid, stress-free, conformal coupling at the bottom of the hole. Experimental test results show this wax-embedded detector to have excellent broadband three-component response at frequencies up to 2,500 Hz; a range heretofore unexplored for seismic applications. The pneumatically coupled detector, although limited by modal resonance distortion effects in the highest range of frequencies, demonstrated useful three-component response at frequencies up to 1,500 Hz. Tests of the two coupling techniques under identical conditions illustrate their high-quality responses and their differences. Field tests of the prototype pneumatically coupled detector in shallow reverse vertical seismic profiling (VSP) measurements demonstrate the practical effectiveness of the basic high-resolution probe design concepts.

  12. The experimentation research of IR imaging system capability affected by sapphire window's pneumatic calefaction

    NASA Astrophysics Data System (ADS)

    Liu, Yang-peng; Pan, Guo-qing; Zhang, Yun-qiang

    2009-07-01

    In the inclement pneumatic calefaction condition, the window of IR imaging system will be calefied and emit infrared radiation, so that the Signal-to-Noise and quality of target IR image are felled off that are from the imaging system. At this rate the physical characteristic of IR window direct affect capability of imaging system controlled and guided homing by IR tracker and measure precision of target IR characteristics. The properties of sapphire make it an ideal choice for the high speed missile applications compared to other existing or emerging materials. But the research has not been reported about the infrared radiation characteristic of sapphire as the IR window. In this paper, based on an IR imaging system using the sapphire window, the experimentation and conclusions of IR thermal image measurement affected by IR window's pneumatic calefaction have been accomplished. Firstly, the temperatures of sapphire window at supersonic flight extended over 1 km and 15 km from the ground have been estimated by calculating the flow and state variables and the aerodynamic heating into the window. On the base of the results calculated the window static state calefaction experimentation and electric arc wind tunnel experimentation had been designed and completed to validate the effect degree of pneumatic calefaction to the imaging system. With the temperatures of the sapphire window rising, in the image coming from the imaging system, the peak luminance of target image detected is increased, the background average luminance of the image is also increased, and the margin of above two varies in a little range. The data obtained from the different temperature experimentation have demonstrated that the IR flux due to the sapphire window becomes heated by friction with the air and heat transfer to the dome can obscure the target image created by the onboard IR sensor, depress Signal-to-Noise and resolving power of the imaging system, but can not overload the detector.

  13. Study on the phase shift characteristic of the pneumatic Stirling cryocooler

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Wu, Yi Nong; Zhang, Hua; Chen, Nan

    2009-03-01

    Due to entire pneumatic connection between free piston and free displacer, the motion parameters of them including amplitude and phase shift can actually impact the cooling capacity and overall performance of cryocooler obviously. In this study, the procedure of design and manufacture pneumatic free piston and free displacer (FPFD) Stirling cryocooler had firstly been described in details. Then in order to accomplish study, the experimental bench has been set up based on 80 K@1 W Stirling cryocooler. The effect of the thermodynamic and pneumatic parameters including charging pressure, natural frequency of displacer, damping coefficient of displacer, working frequency on the pressure, displacement and displacer phase shift has been investigated, respectively by means of experimental and theoretical method. In particular, the variation of damping is realized by adjusting the width of clearance cut on the additional damping component, which is screwed on the displacer rod. Similarly, natural frequency of displacer is changed by the extra mass connected on the displacer. Due to the results of experimental study, the optimum working conditions of this Stirling cryocooler for 80 K cold tip temperature are as follows: charge pressure 15 bar, natural frequency of displacer 46 Hz, width of clearance 300 μm and working frequency 43 Hz. In agreement with the optimum working conditions, neighborhood interval of 90° is the ideal working domain for displacement phase shift. Meanwhile, the displacer phase shift should approach to 0°as near as possible and pressure phase shift should also be as small as possible, which have linear relation with non-dimensional damping characteristic of compressor. In view of theoretical study, the expressions of three phase shifts deduced from thermodynamic equation of piston and displacer respectively are expressed as the functions of working parameters, which are verified by the experimental data and consequently can be used as the powerful

  14. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    SciTech Connect

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.

    2011-04-26

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.

  15. Effects of a Low-Intensity Laser on Dental Implant Osseointegration: Removal Torque and Resonance Frequency Analysis in Rabbits.

    PubMed

    Blay, Alberto; Blay, Claudia C; Tunchel, Samy; Gehrke, Sergio Alexandre; Shibli, Jamil Awad; Groth, Eduardo B; Zezell, Denise M

    2016-08-01

    The objective of this study was to investigate how a low-intensity laser affects the stability and reverse torque resistance of dental implants installed in the tibia of rabbits. Thirty rabbits received 60 dental implants with the same design and surface treatment, one in each proximal metaphysis of the tibia. Three groups were prepared (n = 10 animals each): conventional osseointegration without treatment (control group), surgical sites irradiated with a laser beam emitted in the visible range of 680 nm (Lg1 group), surgical sites irradiated with a laser beam with a wavelength in the infrared range of 830 nm (Lg2 group). Ten irradiation sessions were performed 48 hours apart; the first session was during the immediate postoperative period. Irradiation energy density was 4 J/cm(2) per point in 2 points on each side of the tibias. The resonance frequency and removal torque values were measured at 2 time points after the implantations (3 and 6 weeks). Both laser groups (Lg1 and Lg2) presented a significant difference between resonance frequency analysis values at the baseline and the values obtained after 3 and 6 weeks (P > .05). Although the removal torque values of all groups increased after 6 weeks (P < .05), both laser groups presented greater mean values than those of the control group (P < .01). Photobiomodulation using laser irradiation with wavelengths of 680 and 830 nm had a better degree of bone integration than the control group after 6 weeks of observation time. PMID:26652735

  16. Active control of crossflow-induced transition by means of in-line pneumatic actuator orifices

    NASA Astrophysics Data System (ADS)

    Lohse, J.; Barth, H. P.; Nitsche, W.

    2016-08-01

    The possibility of a pneumatic actuator system for controlling the crossflow vortex-induced laminar breakdown is investigated by means of hot-wire measurements. Steady blowing or suction through a spanwise row of periodically arranged orifices initiates a system of longitudinal vortices which reduces the amplitude of the most amplified stationary crossflow vortices. Thus, the onset of high-frequency secondary instability and the following laminar-turbulent transition was shifted farther downstream. All experiments were conducted at the redesigned DLR swept flat plate experiment in the open test section of the 1 m wind tunnel at the DLR in Göttingen.

  17. Ultrasonic detection of solid phase mass flow ratio of pneumatic conveying fly ash

    NASA Astrophysics Data System (ADS)

    Duan, Guang Bin; Pan, Hong Li; Wang, Yong; Liu, Zong Ming

    2014-04-01

    In this paper, ultrasonic attenuation detection and weight balance are adopted to evaluate the solid mass ratio in this paper. Fly ash is transported on the up extraction fluidization pneumatic conveying workbench. In the ultrasonic test. McClements model and Bouguer-Lambert-Beer law model were applied to formulate the ultrasonic attenuation properties of gas-solid flow, which can give the solid mass ratio. While in the method of weigh balance, the averaged mass addition per second can reveal the solids mass flow ratio. By contrast these two solid phase mass ratio detection methods, we can know, the relative error is less.

  18. Effect of Oxygen Concentration on Autogenous Ignition Temperature and Pneumatic Impact Ignitability of Nonmetallic Materials

    NASA Technical Reports Server (NTRS)

    Smith, Sarah

    2009-01-01

    Extensive test data exist on the ignitability of nonmetallic materials in pure oxygen, but these characteristics are not as well understood for lesser oxygen concentrations. In this study, autogenous ignition temperature testing and pneumatic impact testing were used to better understand the effects of oxygen concentration on ignition of nonmetallic materials. Tests were performed using oxygen concentrations of 21, 34, 45, and 100 %. The following materials were tested: PTFE Teflon(Registered Trademark), Buna-N, Silicone, Zytel(Registered Trademark) 42, Viton(registered Trademark) A, and Vespel(Registered Trademark) SP-21.

  19. Evaluation of a pneumatic boot deicing system on a general aviation wing model

    NASA Technical Reports Server (NTRS)

    Albright, A. E.; Kohlman, D. L.; Schweikhard, W. G.; Evanich, P.

    1981-01-01

    The aerodynamic characteristics of a typical modern general aviation airfoil were investigated with and without a pneumatic boot ice protection system. The ice protection effectiveness of the boot was studied. This includes the change in drag on the airfoil with the boot inflated and deflated, the change in drag due to primary and residual ice formation, drag change due to cumulative residual ice formation, and parameters affecting boot effectiveness. Boot performance was not affected by tunnel total temperature or velocity. Marginal effect in performance was associated with angle of attack. Significant effects on performance were caused by variations in droplet size, LWC, ice cap thickness inflation pressure, and surface treatment.

  20. Vacuum generation in pneumatic artificial heart drives with a specially designed ejector system.

    PubMed

    Schima, H; Huber, L; Spitaler, F

    1990-06-01

    To improve the filling characteristics of pneumatically driven membrane artificial hearts (AHs), a vacuum is applied during diastole. This paper describes an ejector system for AH-drivers based on the Venturi effect, which was designed for this purpose. It provides vacuums of more than -40 mmHg at flow rates up to 50 l/min requiring a supplying primary gas pressure of less than 150 kPa (1140 mmHg). Under normal working conditions, the necessary supply flow was less than 5l/min. The device is small, cheap, quiet and fail-safe, and has been evaluated successfully in experimental and clinical use. PMID:2357149

  1. Wearable air supply for pneumatic artificial hearts and ventricular assist devices.

    PubMed

    Sipin, A J; Fabrey, W J; Smith, S H; Doussourd, J D; Olsen, D B

    1992-08-01

    An experimental wearable air supply for pneumatic artificial hearts and ventricular assist devices has been built and tested. The unit eliminates the need for tethering to a large, stationery driver. The miniaturized air supply is designed for ambulatory patients with implanted pulsatile pneumatic total artificial hearts (TAH) or pneumatic left-ventricular assist devices (LVAD), to permit mobility in clinical and home settings. The device has major short-term utility as a supply for pneumatic TAH or VAD bridges in patients awaiting heart transplants. The system design for the wearable driver includes a novel, fast rotary compressor, driven by a brushless direct current (DC) motor to supply air to the ventricle through an electromagnetically actuated directional valve, all controlled by a microcomputer. Stroke volume from 0 to 200 cc; pulse rate from 60 to 160 bpm, and duty cycle from 33% to 50% are selected on a keyboard, and the selected or measured parameters can be shown on a liquid crystal display. For control of delivery from a single ventricular assist device, stroke volume is controlled by variation of compressor speed. In the wearable air supply for a TAH, a single compressor drives both ventricles alternately through a double-acting directional valve. Air volume delivered to the left ventricle is adjusted by variation of compressor speed, and air volume to the right ventricle by variation of ejection time. The effect on blood flow rate of the lower impedance to the right ventricle is compensated by provision of a two-stage compressor, in which a single stage drives the right ventricle, and both stages connected in parallel drive the left ventricle. The overall dimensions of the prototype air supply for driving either a TAH or LVAD are 4.5 by 7.8 by 4.5 inches, including an emergency battery with a duration of 15 to 30 min depending on load. The weight is presently 5.5 lb, but this will be reduced in a production design and for a dedicated LVAD air supply

  2. Liquid Hydrogen Regulated Low Pressure High Flow Pneumatic Panel AFT Arrow Analysis

    NASA Technical Reports Server (NTRS)

    Jones, Kelley, M.

    2013-01-01

    Project Definition: Design a high flow pneumatic regulation panel to be used with helium and hydrogen. The panel will have two circuits, one for gaseous helium (GHe) supplied from the GHe Movable Storage Units (MSUs) and one for gaseous hydrogen (GH2) supplied from an existing GH2 Fill Panel. The helium will supply three legs; to existing panels and on the higher pressure leg and Simulated Flight Tanks (SFTs) for the lower pressure legs. The hydrogen line will pressurize a 33,000 gallon vacuum jacketed vessel.

  3. Postcranial skeletal pneumaticity and air-sacs in the earliest pterosaurs

    PubMed Central

    Butler, Richard J.; Barrett, Paul M.; Gower, David J.

    2009-01-01

    Patterns of postcranial skeletal pneumatization (PSP) indicate that pterosaurs possessed components of a bird-like respiratory system, including a series of ventilatory air-sacs. However, the presence of PSP in the oldest known pterosaurs has not been unambiguously demonstrated by previous studies. Here we provide the first unequivocal documentation of PSP in Late Triassic and earliest Jurassic pterosaurs. This demonstrates that PSP and, by inference, air-sacs were probably present in the common ancestor of almost all known pterosaurs, and has broader implications for the evolution of respiratory systems in bird-line archosaurs, including dinosaurs. PMID:19411265

  4. Characterization and Prediction of Subsurface Pneumatic PressureVariations at Yucca Mountain, Nevada

    SciTech Connect

    Ahlers, C. Fredrik; Finsterle, Stefan; Bodvarsson, Gudmundur S.

    1998-01-02

    Yucca Mountain, Nevada is being investigated as the proposed site for geologic disposal of high level nuclear waste. A massive data collection effort for characterization of the unsaturated zone is being carried out at the site. The USGS is monitoring the subsurface pressure variations due to barometric pumping in several boreholes. Numerical models are used to simulate the observed subsurface pressure variations. Data inversion is used to characterize the unsaturated system and estimate the pneumatic diffusivity of important geologic features. Blind predictions of subsurface response and subsequent comparison to recorded data have built confidence in the models of Yucca Mountain.

  5. Perioperative external pneumatic calf compression as thromboembolism prophylaxis in gynecologic oncology: report of a randomized controlled trial

    SciTech Connect

    Clarke-Pearson, D.L.; Creasman, W.T.; Coleman, R.E.; Synan, I.S.; Hinshaw, W.M.

    1984-06-01

    Postoperative venous thromboembolic complications are a major problem for the gynecologic oncologist. External pneumatic calf compression (EPC), when applied intraoperatively and left on the patient's legs for 5 days postoperatively, has been previously demonstrated to significantly reduce the incidence of venous thromboembolic complications in patients undergoing surgery for pelvic malignancies. The purpose of this study is to evaluate whether a short perioperative course of EPC is also effective in preventing venous thromboembolic complications. One hundred ninety-four patients participated in a randomized controlled trial of perioperative external pneumatic calf compression. /sup 125/I-labeled fibrinogen scanning and impedance plethysmography were used as prospective surveillance methods in both groups. Venous thromboembolic complications were diagnosed in 12.4% of control group patients and in 18.6% of EPC group patients. External pneumatic calf compression when used only in the perioperative period appears to be of no benefit in reducing the incidence of postoperative venous thromboembolic complications.

  6. An individual-based model of rabbit viral haemorrhagic disease on European wild rabbits (Oryctolagus cuniculus)

    USGS Publications Warehouse

    Fa, John E.; Sharples, Colin M.; Bell, Diana J.; DeAngelis, Donald L.

    2001-01-01

    We developed an individual-based model of Rabbit Viral Hemorrhagic Disease (RVHD) for European wild rabbits (Oryctolagus cuniculus L.), representing up to 1000 rabbits in four hectares. Model output for productivity and recruitment matched published values. The disease was density-dependent and virulence affected outcome. Strains that caused death after several days produced greater overall mortality than strains in which rabbits either died or recovered very quickly. Disease effect also depended on time of year. We also elaborated a larger scale model representing 25 km2 and 100,000+ rabbits, split into a number of grid-squares. This was a more traditional model that did not represent individual rabbits, but employed a system of dynamic equations for each grid-square. Disease spread depended on probability of transmission between neighboring grid-squares. Potential recovery from a major population crash caused by the disease relied on disease virulence and frequency of recurrence. The model's dependence on probability of disease transmission between grid-squares suggests the way that the model represents the spatial distribution of the population affects simulation. Although data on RVHD in Europe are lacking, our models provide a basis for describing the disease in realistic detail and for assessing influence of various social and spatial factors on spread.

  7. Urolithiasis and cystotomy in the rabbit.

    PubMed

    Brown, Cyndi

    2011-03-01

    Cystotomy is a surgical incision into the urinary bladder, which may be required for removal of calculi, diagnosis of tumors or refractory urinary tract infections, or repair of ectopic ureters and ruptured bladders. This column describes the indications and techniques for cystotomy in the rabbit. PMID:21326187

  8. CLONING AND EXPRESSION OF RABBIT INTERLEUKIN-15

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In order to understand the inflammatory mechanisms related to rabbit interleukin-15 (RIL-15), we cloned and expressed RIL-15 cDNA gene. A cDNA encoding RIL-15 was cloned from heart mRNA by reverse transcriptase polymerase chain reaction (RT-PCR) amplification using hIL-15 primers. The RIL-15 cDNA co...

  9. Selective ablation of WHHLMI rabbit atherosclerotic plaque by quantum cascade laser in the 5.7 μm wavelength range for less-invasive laser angioplasty

    NASA Astrophysics Data System (ADS)

    Hashimura, Keisuke; Ishii, Katsunori; Akikusa, Naota; Edamura, Tadataka; Yoshida, Harumasa; Awazu, Kunio

    2013-06-01

    We investigated the potential of a compact and high-power quantum cascade laser (QCL) in the 5.7 μm wavelength range for less-invasive laser angioplasty. Atherosclerotic plaques consist mainly of cholesteryl esters. Radiation at a wavelength of 5.75 μm is strongly absorbed in C=O stretching vibration mode of cholesteryl esters. Our previous study achieved to make cutting differences between a normal artery and an atherosclerotic lesions using nanosecond pulsed laser by difference-frequency generation (DFG laser) at the wavelength of 5.75 μm. For applying this technique to clinical treatment, a compact laser device is required. In this study, QCL irradiation effects to a porcine normal aorta were compared with DFG laser. Subsequently, QCL irradiation effects on an atherosclerotic aorta of myocardial infarction-prone Watanabe heritable hyperlipidemic rabbit (WHHLMI rabbit) and a normal rabbit aorta were observed. As a result, the QCL could make cutting differences between the rabbit atherosclerotic and normal aortas. On the other hand, the QCL induced more thermal damage to porcine normal aorta than the DFG laser at the irradiation condition of comparable ablation depths. In conclusion, the possibility of less-invasive and selective treatment of atherosclerotic plaques using the QCL in the 5.7 μm wavelength range was revealed, although improvement of QCL was required to prevent the thermal damage of a normal artery.

  10. [Food irradiation].

    PubMed

    Migdał, W

    1995-01-01

    A worldwide standard on food irradiation was adopted in 1983 by Codex Alimentarius Commission of the Joint Food Standard Programme of the Food and Agriculture Organization (FAO) of the United Nations and the World Health Organization (WHO). As a result, 41 countries have approved the use of irradiation for treating one or more food items and the number is increasing. Generally, irradiation is used to: food loses, food spoilage, disinfestation, safety and hygiene. The number of countries which use irradiation for processing food for commercial purposes has been increasing steadily from 19 in 1987 to 33 today. In the frames of the national programme on the application of irradiation for food preservation and hygienization an experimental plant for electron beam processing has been established in Institute of Nuclear Chemistry and Technology. The plant is equipped with a small research accelerator Pilot (19MeV, 1 kW) and an industrial unit Elektronika (10MeV, 10 kW). On the basis of the research there were performed at different scientific institutions in Poland, health authorities have issued permission for irradiation for: spices, garlic, onions, mushrooms, potatoes, dry mushrooms and vegetables. PMID:8619113

  11. Tissue irradiator

    DOEpatents

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1975-12-16

    A tissue irradiator is provided for the in-vivo irradiation of body tissue. The irradiator comprises a radiation source material contained and completely encapsulated within vitreous carbon. An embodiment for use as an in- vivo blood irradiator comprises a cylindrical body having an axial bore therethrough. A radioisotope is contained within a first portion of vitreous carbon cylindrically surrounding the axial bore, and a containment portion of vitreous carbon surrounds the radioisotope containing portion, the two portions of vitreous carbon being integrally formed as a single unit. Connecting means are provided at each end of the cylindrical body to permit connections to blood- carrying vessels and to provide for passage of blood through the bore. In a preferred embodiment, the radioisotope is thulium-170 which is present in the irradiator in the form of thulium oxide. A method of producing the preferred blood irradiator is also provided, whereby nonradioactive thulium-169 is dispersed within a polyfurfuryl alcohol resin which is carbonized and fired to form the integral vitreous carbon body and the device is activated by neutron bombardment of the thulium-169 to produce the beta-emitting thulium-170.

  12. Risk of zoonotic transmission of HEV from rabbits.

    PubMed

    Lhomme, Sébastien; Dubois, Martine; Abravanel, Florence; Top, Sokunthea; Bertagnoli, Stéphane; Guerin, Jean-Luc; Izopet, Jacques

    2013-10-01

    Hepatitis E virus strains from rabbits indicate that these mammals may be a reservoir for HEVs that cause infection in humans. Further issues remain to be clarified, including whether the genotype of rabbit HEV differs from human and swine HEV genotype 3 and whether rabbit HEV can infect human and other animals. HEV was found in farmed rabbits in several geographic areas of China, in USA and more recently in France. The prevalence of antibodies against HEV was 36%, 57% and 55% in rabbits from Virginia (USA), Gansu Province and Beijing (China), respectively. HEV RNA was detected in 16.5% of serum samples from farmed rabbits in Virginia, 7.5% in Gansu Province and 7.0% in Beijing. HEV RNA was detected in 7% of bile samples from farmed rabbits and in 23% of liver samples from wild rabbits in France. The full-length genomic sequences analysis indicates that all the rabbit strains belong to the same clade. Nucleotide sequences were 72.2-78.2% identical to HEV genotypes 1-4. Comparison with HEV sequences of human strains circulating in France and reference sequences identified a human strain closely related to rabbit HEV. A 93-nucleotide insertion in the X domain of the ORF1 of the human strain and in all the rabbit HEV strains was found. Moreover, the ability of rabbit HEV to cause cross-species infection in a pig model has recently been demonstrated. Rabbit HEV can replicate efficiently in human cell lines. Collectively, these data support the possibility of zoonotic transmission of HEV from rabbits. PMID:23474012

  13. Pneumatic otoscopy in the diagnosis of middle ear effusion: the use of video as a teaching aid.

    PubMed

    Burke, P; Jones, W

    1989-01-01

    A recent survey has shown that the average general practitioner could expect to see 40 episodes of middle ear effusion in one year. It is an important condition because of its frequency, its insidious onset, and its persistence. It is presently associated with hearing loss, resulting in educational and social disadvantages. A more accurate diagnosis can be made over other conventional methods by the use of pneumatic otoscopy. It is a technique that is not widely used by general practitioners in this country. A videotape was produced to demonstrate the behaviour of the normal and abnormal eardrum during pneumatic otoscopy. This paper gives a review of how this was achieved. PMID:2809076

  14. Immune complex orchitis in vasectomized rabbits.

    PubMed

    Bigazzi, P E; Kosuda, L L; Hsu, K C; Andres, G A

    1976-02-01

    The results of the present study show that bilaterally vasectomized rabbits with high levels of antibodies to sperm antigens frequently develop an orchitis associated with granular deposits of rabbit IgG and C3 in the basement membranes of seminiferous tubules. The immune deposits correspond in location to electron-opaque deposits seen by electron microscopy. The "membranous orchitis" is characterized by thickening of tubular basement membranes, acc-mulation of macrophages and a few polymorphonuclear leukocytes, and destruction of the basal lamina, of the Sertoli and spermatogenetic cells. The pathogenetic role of the immune deposits and the possibility that they contain antigen-antibody complexes is indicated by: (a) selective accumulation of IgG and C3 granular deposits along the basement membranes of seminiferous tubules in rabbits producing high and persistent levels of antibodies to sperm antigens; (b) the elution of immunoglobulins from tissues with chaotropic ion-containing buffers, acid buffers, or heat; (c) the observation that the immuno-globulins accumulated in the testis contain antibody to sperm antigens; and (d) the demonstration of sperm antigens in a location similar to that of IgG and C3. It is postulated that sperm antigen-antibody complexes are formed in the basement membranes of seminiferous tubules when antigens leaking out of the tubules react with specific antibody coming from the circulation. In two rabbits with higher levels of circulating antisperm antibodies and severe orchitis, granular deposits of IgG and C3 were also present in renal glomeruli. Immunoglobulins eluted from the kidneys contained antibody with antisperm activity. These findings are consistent with the hypothesis that in some vasectomized rabbits extratesticular lesions may develop by a mechanism comparable to that of chronic serum sickness. PMID:129498

  15. STATUS OF HIGH FLUX ISOTOPE REACTOR IRRADIATION OF SILICON CARBIDE/SILICON CARBIDE JOINTS

    SciTech Connect

    Katoh, Yutai; Koyanagi, Takaaki; Kiggans, Jim; Cetiner, Nesrin; McDuffee, Joel

    2014-09-01

    Development of silicon carbide (SiC) joints that retain adequate structural and functional properties in the anticipated service conditions is a critical milestone toward establishment of advanced SiC composite technology for the accident-tolerant light water reactor (LWR) fuels and core structures. Neutron irradiation is among the most critical factors that define the harsh service condition of LWR fuel during the normal operation. The overarching goal of the present joining and irradiation studies is to establish technologies for joining SiC-based materials for use as the LWR fuel cladding. The purpose of this work is to fabricate SiC joint specimens, characterize those joints in an unirradiated condition, and prepare rabbit capsules for neutron irradiation study on the fabricated specimens in the High Flux Isotope Reactor (HFIR). Torsional shear test specimens of chemically vapor-deposited SiC were prepared by seven different joining methods either at Oak Ridge National Laboratory or by industrial partners. The joint test specimens were characterized for shear strength and microstructures in an unirradiated condition. Rabbit irradiation capsules were designed and fabricated for neutron irradiation of these joint specimens at an LWR-relevant temperature. These rabbit capsules, already started irradiation in HFIR, are scheduled to complete irradiation to an LWR-relevant dose level in early 2015.

  16. Crossbreeding effects on rabbit reproduction from four maternal lines of rabbits.

    PubMed

    Ragab, M; Sánchez, J P; Mínguez, C; Baselga, M

    2016-07-01

    Litter size is essential for an efficient production of rabbit meat. A diallel cross between four maternal lines was carried out and the analysis of the components of litter size has been already done. This paper presents the analysis of litter size traits themselves (total born (TB), number born alive (NBA), number weaned (NW)) and kindling interval (KI), that complete the analysis of the reproductive performance. The 16 genetic groups were distributed in four Spanish farms. The V line was present in all farms in order to be used as reference group. A total of 34 546 parities from 7111 does, were analysed. The crossbreeding parameters were estimated according to Dickerson model. The differences between lines performance were of low magnitude and not significant for litter size traits. The LP line showed the shortest KI followed by H respect to lines A and V. These differences reflected the differences between direct and maternal genetic effects. The differences between the average of all crosses and line V were found to be significant and seemed to be important, being 0.46 for TB, 0.56 for NBA, 0.75 for NW and -2.21 days for KI. The differences between reciprocal crosses for litter size were of low magnitude and non-significant, which indicate that the maternal effects are not important between these lines. In general, the lines did not show significant differences in direct and maternal genetic effects for TB, NBA and NW but there were some significant differences for KI, which ranged from 1.54 to 6.85 days in direct effects and from 0.63 to 3.38 days for maternal effects. A positive and, in some cases, relevant heterosis was found. The largest heterosis was for TB in the HV cross (1.05 rabbits), followed by the AH (0.74 rabbits), AV (0.57 rabbits) and LH (0.55 rabbits) crosses. For NBA, significant heterosis was found in HV (1.11 rabbits) and AV (0.49 rabbits) and for NW in AV (0.90 rabbits), LH (0.70 rabbits) and LV (0.58 rabbits). Favourable and significant

  17. Recombinant Rabbit Leukemia Inhibitory Factor and Rabbit Embryonic Fibroblasts Support the Derivation and Maintenance of Rabbit Embryonic Stem Cells

    PubMed Central

    Xue, Fei; Ma, Yinghong; Chen, Y. Eugene; Zhang, Jifeng; Lin, Tzu-An; Chen, Chien-Hong; Lin, Wei-Wen; Roach, Marsha; Ju, Jyh-Cherng; Yang, Lan; Du, Fuliang

    2012-01-01

    Abstract The rabbit is a classical experimental animal species. A major limitation in using rabbits for biomedical research is the lack of germ-line-competent rabbit embryonic stem cells (rbESCs). We hypothesized that the use of homologous feeder cells and recombinant rabbit leukemia inhibitory factor (rbLIF) might improve the chance in deriving germ-line-competent rbES cells. In the present study, we established rabbit embryonic fibroblast (REF) feeder layers and synthesized recombinant rbLIF. We derived a total of seven putative rbESC lines, of which two lines (M5 and M23) were from culture Condition I using mouse embryonic fibroblasts (MEFs) as feeders supplemented with human LIF (hLIF) (MEF+hLIF). Another five lines (R4, R9, R15, R21, and R31) were derived from Condition II using REFs as feeder cells supplemented with rbLIF (REF+rbLIF). Similar derivation efficiency was observed between these two conditions (8.7% vs. 10.2%). In a separate experiment with 2×3 factorial design, we examined the effects of feeder cells (MEF vs. REF) and LIFs (mLIF, hLIF vs. rbLIF) on rbESC culture. Both Conditions I and II supported satisfactory rbESC culture, with similar or better population doubling time and colony-forming efficiency than other combinations of feeder cells with LIFs. Rabbit ESCs derived and maintained on both conditions displayed typical ESC characteristics, including ESC pluripotency marker expression (AP, Oct4, Sox2, Nanog, and SSEA4) and gene expression (Oct4, Sox2, Nanog, c-Myc, Klf4, and Dppa5), and the capacity to differentiate into three primary germ layers in vitro. The present work is the first attempt to establish rbESC lines using homologous feeder cells and recombinant rbLIF, by which the rbESCs were derived and maintained normally. These cell lines are unique resources and may facilitate the derivation of germ-line-competent rbESCs. PMID:22775411

  18. A pneumatic pressure-driven multi-throughput microfluidic circulation culture system.

    PubMed

    Satoh, T; Narazaki, G; Sugita, R; Kobayashi, H; Sugiura, S; Kanamori, T

    2016-06-21

    Here, we report a pneumatic pressure-driven microfluidic device capable of multi-throughput medium circulation culture. The circulation culture system has the following advantages for application in drug discovery: (i) simultaneous operation of multiple circulation units, (ii) use of a small amount of circulating medium (3.5 mL), (iii) pipette-friendly liquid handling, and (iv) a detachable interface with pneumatic pressure lines via sterile air-vent filters. The microfluidic device contains three independent circulation culture units, in which human umbilical vein endothelial cells (HUVECs) were cultured under physiological shear stress induced by circulation of the medium. Circulation of the medium in the three culture units was generated by programmed sequentially applied pressure from two pressure-control lines. HUVECs cultured in the microfluidic device were aligned under a one-way circulating flow with a shear stress of 10 dyn cm(-2); they exhibited a randomly ordered alignment under no shear stress and under reciprocating flow with a shear stress of 10 dyn cm(-2). We also observed 2.8- to 4.9-fold increases in expression of the mRNAs of endothelial nitric oxide synthase and thrombomodulin under one-way circulating flow with a shear stress of 10 dyn cm(-2) compared with conditions of no shear stress or reciprocating flow. PMID:27229626

  19. Space Station and Shuttle Payloads: Rack Insertion Device Pneumatic Assembly Setup and Test

    NASA Technical Reports Server (NTRS)

    Conde, Nathan

    2007-01-01

    As part of my KSC summer internship, I was given the very cool task of writing a test preparation sheet (TPS). A TPS is a set of instructions for certain procedures or tasks, and serves as the documentation for the tasks. TPSs guide task leaders and technicians throughout the work procedures, safely, informing them of what steps will be hazardous, what precautions must be taken, and what to do in the case of an accident or emergency. I was placed in Boeing's Resupply & Return Division (R&R). R&R is responsible for sending up food and supplies to the International Space Station (ISS) with the use of three Italian Multi Purpose Logistics Modules - Leonardo, Donatello, and Raffaello. The supplies are loaded into Resupply Stowage Racks (RSRs) or Resupply Stowage Platforms (RSPs) (though, both are usually referred to as racks), depending on their size and shape. These racks are loaded into the modules with the help of a specialized crane known as the Rack Insertion Device (RID). The RID rests on four pneumatic air jacks, these allow for an operator to raise or lower the RID. The pneumatic air system supplies the air jacks with the necessary air pressure required to lift the RID.

  20. Application of Pneumatic Flow Injection-Tandem Spectrometer System for Chromium Speciation

    PubMed Central

    Noroozifar, Meissam; Khorasani-Motlagh, Mozhgan; Akbari, Reza

    2007-01-01

    In this approach, a pneumatic flow injection-tandem spectrometer system, without a delivery pump, has been developed to study chromium speciation. In this system, suction force of pneumatic nebulizer of a flame atomic absorption spectrometer has been used for solution delivery through the manifold. Cr(VI) and total Cr concentrations were determined using UV-Vis and FAAS spectrometers, respectively. The Cr(III) was determined by difference. The calibration curves were linear up to 10 μg mL−1 and 20 μg mL−1 for Cr(VI) and total Cr with detection limit of 0.12 μg mL−1 and 0.07 μg mL−1 for Cr(VI) and Cr(III), respectively. The midrange precision and accuracy are less than 1.98% and ± 2.50% for two species, respectively, at a sampling rate of 100 h−1. This system was applied for the determination of the chromium species in spiked and natural waters as well as industrial waters. PMID:18273388

  1. Methane emissions from process equipment at natural gas production sites in the United States: pneumatic controllers.

    PubMed

    Allen, David T; Pacsi, Adam P; Sullivan, David W; Zavala-Araiza, Daniel; Harrison, Matthew; Keen, Kindal; Fraser, Matthew P; Daniel Hill, A; Sawyer, Robert F; Seinfeld, John H

    2015-01-01

    Emissions from 377 gas actuated (pneumatic) controllers were measured at natural gas production sites and a small number of oil production sites, throughout the United States. A small subset of the devices (19%), with whole gas emission rates in excess of 6 standard cubic feet per hour (scf/h), accounted for 95% of emissions. More than half of the controllers recorded emissions of 0.001 scf/h or less during 15 min of measurement. Pneumatic controllers in level control applications on separators and in compressor applications had higher emission rates than controllers in other types of applications. Regional differences in emissions were observed, with the lowest emissions measured in the Rocky Mountains and the highest emissions in the Gulf Coast. Average methane emissions per controller reported in this work are 17% higher than the average emissions per controller in the 2012 EPA greenhouse gas national emission inventory (2012 GHG NEI, released in 2014); the average of 2.7 controllers per well observed in this work is higher than the 1.0 controllers per well reported in the 2012 GHG NEI. PMID:25488196

  2. Supinator Extender (SUE): a pneumatically actuated robot for forearm/wrist rehabilitation after stroke.

    PubMed

    Allington, James; Spencer, Steven J; Klein, Julius; Buell, Meghan; Reinkensmeyer, David J; Bobrow, James

    2011-01-01

    The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring. Each degree of freedom has a range of 90 degrees, and a nominal torque of 2 ft-lbs. The cylinders are mounted away from the patient's body on the lateral aspect of the arm. This is to prevent the danger of a collision and maximize the workspace of the arm robot. The rotation axis used for supination-pronation is a small bearing just below the subject's wrist. The flexion-extension motion is actuated by a cantilevered pneumatic cylinder, which allows the palm of the hand to remain open. Data are presented that demonstrate the ability of SUE to measure and cancel forearm/wrist passive tone, thereby extending the active range of motion for people with stroke. PMID:22254624

  3. A study of pneumatic conveying of gas-solid flow for industrial application

    NASA Astrophysics Data System (ADS)

    Al-Khateeb, Khalid A. S.; Tasnim, Rumana; Khan, Sheroz; Mohammod, Musse; Arshad, Atika; Shobaki, Mohammed M.; Haider, Samnan; Saquib, Nazmus; Rahman, Tawfilur

    2013-12-01

    The complicated nature of gas-solids' physical properties have challenged the researchers over past decades who have led their efforts in developing its' flow sensing and measurement methods. The term 'gas-solid flow' signifies dilute- or dense-phase flow with a very little concentration of solids. For conducting such flow measurement, generally velocity profile and volumetric concentration of the flow particles being conveyed are needed to be measured. An important application of gas-solid flow has taken root in the form of biomass flow in pneumatic conveying systems, and its' online measurement has proven to be an exigent research pursuit. Additionally the other applications have been explored in power plants, food, chemical and automobiles industries as well. This paper aims at exploring the evolution of flow measurement methods along with a brief explanation on existing fundamental sensing techniques. Furthermore, the most recent patents developed for such measurements in pneumatic conveying pipelines are scrutinized along with their concomitant pros and cons.

  4. Pneumatic flow injection analysis-tandem spectrometer system for iron speciation.

    PubMed

    Noroozifar, Meissam; Khorasani-Motlagh, Mozhgan; Akbari, Reza

    2006-01-01

    A pneumatic flow injection-tandem spectrometer system, without a delivery pump was used for the speciation of iron. In this system, the suction force of a pneumatic nebulizer of a flame absorption spectrometer was used for solution delivery through the manifold. The Fe(III) and total Fe concentrations were determined using thiocyanate ion in a UV-Vis spectrometer and a FAAS, respectively. The Fe(II) was determined by the difference. The calibration curves were linear up to 18 microg mL(-1) and 25 microg mL(-1) with detection limits of 0.09 microg mL(-1) and 0.07 microg mL(-1) for Fe(III) and Fe(II), respectively. The mid-range precision and accuracy were <2.5% and +/-3% for the two species, respectively, at a sampling rate of 120 h(-1). This system was applied for the determination of Fe(III) and Fe(II) in industrial water, natural water and spiked samples. PMID:16429790

  5. Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.

    PubMed

    Wilkening, André; Baiden, David; Ivlev, Oleg

    2012-12-01

    Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart. PMID:23241570

  6. A novel pneumatic micropipette aspiration method using a balance pressure model

    NASA Astrophysics Data System (ADS)

    Zhao, Qili; Wu, Ming; Cui, Maosheng; Qin, Yanding; Yu, Jin; Sun, Mingzhu; Zhao, Xin; Feng, Xizeng

    2013-12-01

    This paper presents a novel micropipette aspiration (MA) method based on a common pneumatic micro-injection system. This method is the first to quantify the influence of capillary effect on aspiration pressure using a balance pressure model, and in return, uses the capillary effect to quantify the aspiration pressure. Subsequently, the seal between the cell and the micropipette is detected to judge and exclude the ineffective MA attempts. The rationality of the balance pressure model is validated by the designed micropipette-filling experiments. Through applied to elasticity-determination of the cells with different sizes, the feasibility and versatility of this MA method are proved. With abilities to quantify aspiration pressures and detect the seam between the cell and the micropipette, our method is expected to advance the application of the commercial pneumatic injector in the MA of cells. Moreover, with the quantified volume of the liquid entering into the micropipette during MA process, our method also has a potential applicability to the study of the permeability of the cell membrane in the future.

  7. Design of a Pneumatic Tool for Manual Drilling Operations in Confined Spaces

    NASA Astrophysics Data System (ADS)

    Janicki, Benjamin

    This master's thesis describes the design process and testing results for a pneumatically actuated, manually-operated tool for confined space drilling operations. The purpose of this device is to back-drill pilot holes inside a commercial airplane wing. It is lightweight, and a "locator pin" enables the operator to align the drill over a pilot hole. A suction pad stabilizes the system, and an air motor and flexible drive shaft power the drill. Two testing procedures were performed to determine the practicality of this prototype. The first was the "offset drill test", which qualified the exit hole position error due to an initial position error relative to the original pilot hole. The results displayed a linear relationship, and it was determined that position errors of less than .060" would prevent the need for rework, with errors of up to .030" considered acceptable. For the second test, a series of holes were drilled with the pneumatic tool and analyzed for position error, diameter range, and cycle time. The position errors and hole diameter range were within the allowed tolerances. The average cycle time was 45 seconds, 73 percent of which was for drilling the hole, and 27 percent of which was for positioning the device. Recommended improvements are discussed in the conclusion, and include a more durable flexible drive shaft, a damper for drill feed control, and a more stable locator pin.

  8. Centrifugo-pneumatic sedimentation, re-suspension and transport of microparticles.

    PubMed

    Zhao, Y; Schwemmer, F; Zehnle, S; von Stetten, F; Zengerle, R; Paust, N

    2015-11-01

    Microparticles are widely used as solid phase for affinity-based separation. Here, we introduce a new method for automated handling of microparticles in centrifugal microfluidics that is not restricted by the particle size and requires neither auxiliary means such as magnets nor coating of microfluidic structures. All steps are initiated and controlled by the speed of rotation only. It is based on storage and "on demand" release of pneumatic energy within tunable time frames: a slow release of the pneumatic energy triggers a first fluidic path through which the supernatant above the sedimented particles is removed. An abrupt release triggers a second path which allows for liquid routing and transport of the re-suspended particles. Re-suspension of particles is thereby achieved by quickly changing the speed of rotation. We demonstrate the exchange of the particle carrier medium with a supernatant removal efficiency of more than 99.5% and a particle loss below 4%. Re-suspension and subsequent transport of suspended particles show a particle loss below 7%. The method targets the automation of particle-based assays e.g. DNA extractions and immunoassays. It is compatible with monolithic integration and suitable for mass production technologies e.g. thermoforming or injection moulding. PMID:26348615

  9. Water gate array for current flow or tidal movement pneumatic harnessing system

    DOEpatents

    Gorlov, Alexander M.

    1991-01-01

    The invention, which provides a system for harnessing power from current flow or tidal movement in a body of water, comprises first and second hydro-pneumatic chambers each having ingress and egress below the water surface near the river or ocean floor and water gates operative to open or seal the ports to the passage of water. In an exemplary embodiment, the gates are sychronized by shafts so that the ingress ports of each chamber are connected to the egress ports of each other chamber. Thus, one set of gates is closed, while the other is open, thereby allowing water to flow into one chamber and build air pressure therein and allowing water to flow out of the other chamber and create a partial vacuum therein. A pipe connects the chambers, and an air turbine harnesses the air movement within the pipe. When water levels are equilibrated, the open set of gates is closed by a counterweight, and the other set is allowed to open by natural force of the water differential. The water gates may be comprised of a plurality of louvers which are ganged for simultaneous opening and closing. The system is designed to operate with air turbines or other pneumatic devices. Its design minimizes construction cost and environmental impact, yet provides a clean renewable energy source.

  10. Fabrication, assembly, bench and drilling tests of two prototype downhole pneumatic turbine motors: Final technical report

    SciTech Connect

    Bookwalter, R.; Duettra, P.D.; Johnson, P.; Lyons, W.C.; Miska, S.

    1987-04-01

    The first and second prototype downhole pneumatic turbine motors have been fabricated, assembled and tested. All bench tests showed that the motor will produce horsepower and bit speeds approximating the predicted values. Specifically, the downhole pneumatic turbine motor produced approximately 50 horsepower at 100 rpm, while being supplied with about 3600 SCFM of compressed air. The first prototype was used in a drilling test from a depth of 389 feet to a depth of 789 feet in the Kirtland formation. This first prototype motor drilled at a rate exceeding 180 ft/hr, utilizing only 3000 SCFM of compressed air. High temperature tests (at approximately 460/sup 0/F) were carried out on the thrust assembly and the gearboxes for the two prototypes. These components operated successfully at these temperatures. Although the bench and drilling tests were successful, the tests revealed design changes that should be made before drilling tests are carried out in geothermal boreholes at the Geysers area, near Santa Rosa, California.

  11. Design of a pneumatically powered wearable exoskeleton with biomimetic support and actuation

    NASA Astrophysics Data System (ADS)

    Sergeyev, A.; Alaraje, N.; Seidel, C.; Carlson, Z.; Breda, B.

    Powered exoskeletons are designed to assist and protect the wearer. Depending on the situation they may be used to protect soldiers and construction workers, aid the survival of people in dangerous environments, or assist patients in rehabilitation. Regardless of the application there are strict requirements for designing and producing exoskeleton suites. They must be durable but light weight and flexible, have reliable power control and modulation, capable of detecting unsafe and invalid motions, and may require significant weight lifting capabilities. In this article we present an on-going research on robotic exoskeleton replicating of human muscle functions. A single wearable knee-joint prototype described in this article combines the use of soft pneumatic muscle-like actuators and a control system based off the users own natural muscle signals. The Pneumatic Exoskeleton uses bioelectrical signals to detect movement intention from the pilot. This paper details the technical design aspects of a lower-limb robotic exoskeleton with possibility of further expansion to fully functioning robotic exoskeleton suit.

  12. Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis.

    PubMed

    Gordon, Keith E; Sawicki, Gregory S; Ferris, Daniel P

    2006-01-01

    We developed a powered ankle-foot orthosis that uses artificial pneumatic muscles to produce active plantar flexor torque. The purpose of this study was to quantify the mechanical performance of the orthosis during human walking. Three subjects walked at a range of speeds wearing ankle-foot orthoses with either one or two artificial muscles working in parallel. The orthosis produced similar total peak plantar flexor torque and network across speeds independent of the number of muscles used. The orthosis generated approximately 57% of the peak ankle plantar flexor torque during stance and performed approximately 70% of the positive plantar flexor work done during normal walking. Artificial muscle bandwidth and force-length properties were the two primary factors limiting torque production. The lack of peak force and work differences between single and double muscle conditions can be explained by force-length properties. Subjects altered their ankle kinematics between conditions resulting in changes in artificial muscle length. In the double muscle condition greater plantar flexion yielded shorter artificial muscles lengths and decreased muscle forces. This finding emphasizes the importance of human testing in the design and development of robotic exoskeleton devices for assisting human movement. The results of this study outline the mechanical performance limitations of an ankle-foot orthosis powered by artificial pneumatic muscles. This orthosis could be valuable for gait rehabilitation and for studies investigating neuromechanical control of human walking. PMID:16023126

  13. Effects of Working Angle on Pneumatic Down-the-hole Hammer Drilling

    NASA Astrophysics Data System (ADS)

    Zhao, Zhi; Meng, Yingfeng; Li, Yongjie; Shi, Xiangchao; Xiang, Chengliao

    2015-09-01

    The effects of the wor king angle on pneumatic down-the-hole (DTH) hammer drilling was investigated since these hammers were developed for vertical drilling and their performances in inclined positions need to be tested. The investigation begins by establishing a calculation model with which to simulate the percussive drilling of the hammer. The model consists of two parts. The first gives the kinetic energy of the piston at impact by simulating the thermodynamic cycle of the DTH hammer, and the second simulates the percussive drilling process according to the analyses of stress-wave propagation. In the meantime, a laboratory-scale test device was made for multi-angle hammer drilling tests. This device is based on a small pneumatic DTH hammer used in deep well drilling. By analyzing the force acting on the rock during impact at different angles, the percussive drilling process is carefully examined. Theoretical predictions and experimental results appear in fairly good agreement. The hammer's working performance in inclined positions can be obtained directly using the proposed model. Furthermore, when detailed evaluation is required, the hammer can be tested using the method proposed in this paper.

  14. Humphry Davy, nitrous oxide, the Pneumatic Institution, and the Royal Institution.

    PubMed

    West, John B

    2014-11-01

    Humphry Davy (1778-1829) has an interesting place in the history of respiratory gases because the Pneumatic Institution in which he did much of his early work signaled the end of an era of discovery. The previous 40 years had seen essentially all of the important respiratory gases described, and the Institution was formed to exploit their possible value in medical treatment. Davy himself is well known for producing nitrous oxide and demonstrating that its inhalation could cause euphoria and heightened imagination. His thinking influenced the poets Samuel Taylor Coleridge and William Wordsworth, and perhaps we can claim that our discipline colored the poetry of the Romantic Movement. Davy was also the first person to measure the residual volume of the lung. The Pneumatic Institution was the brainchild of Thomas Beddoes, who had trained in Edinburgh under Joseph Black, who discovered carbon dioxide. Later Davy moved to the Royal Institution in London formed, in part, to diffuse the knowledge of scientific discoveries to the general public. Davy was a brilliant lecturer and developed an enthusiastic following. In addition he exploited the newly described electric battery to discover several new elements. He also invented the safety lamp in response to a series of devastating explosions in coal mines. Ultimately Davy became president of the Royal Society, a remarkable honor for somebody with such humble origins. Another of his important contributions was to introduce Michael Faraday (1791-1867) to science. Faraday became one of the most illustrious British scientists of all time. PMID:25172910

  15. Pneumatic artificial rubber muscle using shape-memory polymer sheet with embedded electrical heating wire

    NASA Astrophysics Data System (ADS)

    Takashima, Kazuto; Sugitani, Kazuhiro; Morimoto, Naohiro; Sakaguchi, Seiya; Noritsugu, Toshiro; Mukai, Toshiharu

    2014-12-01

    Shape-memory polymer (SMP) can be deformed by applying a small load above its glass transition temperature (Tg). Shape-memory polymer maintains its shape after it has cooled below Tg and returns to a predefined shape when subsequently heated above Tg. The reversible change in the elastic modulus between the glassy and rubbery states of an SMP can be on the order of several hundred times. Based on the change in stiffness of the SMP in relation to the change in temperature, the present study attempts to evaluate the application of the SMP to soft actuators of a robot. In order to control the temperature of the SMP, we developed an SMP sheet with an embedded electrical heating wire. We formed a uniform, thin SMP sheet without air bubbles using a heat press. The SMP sheet with a heating wire can be heated quickly and can be maintained at a constant temperature. Moreover, the effects of the embedded wire on the mechanical properties in bending and tensile tests were small. Then, we applied the SMP sheet with the embedded electrical heating wire to a pneumatic artificial rubber muscle. The enhanced versatility of SMP sheet applications is demonstrated through a series of experiments conducted using a prototype. The initial shape and bending displacement of the pneumatic artificial rubber muscle can be changed by controlling the temperature of the SMP sheet.

  16. Vitreous flow rates through dual pneumatic cutters: effects of duty cycle and cut rate

    PubMed Central

    Abulon, Dina Joy K

    2015-01-01

    Purpose We aimed to investigate effects of instrument settings on porcine vitreous flow rates through dual pneumatic high-speed vitrectomy probes. Methods The CONSTELLATION® Vision System was tested with 250, 450, and 650 mmHg of vacuum using six ULTRAVIT® vitrectomy probes of each diameter (25+®, 25, 23, and 20 gauge) operated from 500 cuts per minute (cpm) up to 5,000 cpm. Duty cycle modes tested included biased open, 50/50, and biased closed. Flow rates were calculated by assessing the change in weight of porcine eyes during vitreous aspiration. Volumetric flow rate was measured with a computer-connected electronic scale. Results At lower cut rates, the biased open mode produced higher flow than did the 50/50 mode, which produced higher flow than did the biased closed mode. In the biased closed and 50/50 modes, vitreous flow rates tended to increase with increasing cut rate. Vitreous flow rates in the biased open duty cycle mode remained relatively constant across cut rates. Conclusion Vitreous flow rates through dual pneumatic vitrectomy probes could be manipulated by changing the duty cycle modes on the vitrectomy system. Differences in duty cycle behavior suggest that high-speed cut rates of 5,000 cpm may optimize vitreous aspiration. PMID:25709386

  17. A Comparative Study of Retinal Function in Rabbits after Panretinal Selective Retina Therapy versus Conventional Panretinal Photocoagulation

    PubMed Central

    Park, Young Gun; Kang, Seungbum; Brinkmann, Ralf; Roh, Young-Jung

    2015-01-01

    Purpose. This study evaluates functional changes in electroretinographic findings after selective retina therapy (SRT) compared to panretinal photocoagulation (PRP) in rabbits. Methods. The right eyes of 12 Chinchilla rabbits received 200 laser treatment spots. The right eyes of six rabbits received SRT (SRT group), whereas the other six animals were treated using PRP on the right eye (PRP group). The eyes were investigated using full-field ERG 1 hour and 3 weeks after treatment. Histologic exam to assess the tissue response of lasers was performed on 3 weeks. Results. No significant changes in the mean ROD or CR b-wave amplitudes of the SRT lesions were evident, compared to baseline, 1 h after laser treatment (p = 0.372 and 0.278, resp.). In addition, the OPs and 30 Hz flickers of the SRT lesions were not significantly altered (p = 0.17 and 0.243, resp.). At 3 weeks, similar results were found. Comparing the two groups, the ROD b-wave amplitude was reduced in the PRP and SRT groups to 60.04 ± 4.2% and 92.32 ± 6.43% of baseline (p < 0.001). Histologically, there was no visible photoreceptor alterations on week 3. Conclusions. SRT in rabbit eyes induced less functional loss than PRP in both rod-mediated retinal function and cone-mediated retinal function. In addition, SRT irradiated eyes had no functional loss compared to its control. PMID:26525905

  18. Characterization of rabbit CD5 isoforms.

    PubMed

    Pospisil, Richard; Kabat, Juraj; Mage, Rose G

    2009-08-01

    Previously described polyclonal or monoclonal antibodies (mAb) to rabbit CD5, raised against expressed recombinant protein or peptides, recognize CD5 on most rabbit B cells. The mAb KEN-5 was originally reported to recognize rabbit CD5. However, KEN-5 binds almost exclusively to T cells and only to a minor population of B cells. We show here that by Enzyme-linked Immunosorbent Assay (ELISA), KEN-5 binds to recombinant rabbit CD5. This interaction is partially inhibited by polyclonal goat anti-CD5 antibody. In addition, immunoprecipitations from lysates of surface biotinylated rabbit lymphocytes with KEN-5 or our anti-CD5 mAb isolate molecules that migrate identically on gels with the same approximate relative molecular mass of 67,000 M(r). By flow cytometric analyses of individual cells from spleen, thymus and appendix, KEN-5 recognizes CD5-like molecules mainly on T cells and on 3-6% of IgM(+) B cells. Immunohistochemical staining of splenic and appendix tissues and confocal immunofluorescent imaging confirm and extend results from flow cytometric analyses. Quantitation of fluorescent colocalization indicates that staining by KEN-5 colocalizes with staining by anti-CD5 on small percentage lymphocytes in splenic tissue sections. As CD5 has both N- and O-linked glycosylation, we hypothesised that differential binding of KEN-5 to T cells and B-cells may be explained by different glycan structures on the CD5 present on T compared to B cells. This hypothesis is supported by ELISA data that show that deglycosylation diminishes the binding of KEN-5 to recombinant rabbit CD5. Screening KEN-5 on an array with 406 glycans was inconclusive. Although we did not identify a strongly binding glycan structure, the data are suggestive that the epitope recognized by KEN-5 may be influenced by glycan structures. The epitope this mAb recognizes may either be the glycan itself, or more likely, is influenced by neighboring glycan structure. Our findings suggest that development

  19. Irradiation subassembly

    DOEpatents

    Seim, O.S.; Filewicz, E.C.; Hutter, E.

    1973-10-23

    An irradiation subassembly for use in a nuclear reactor is described which includes a bundle of slender elongated irradiation -capsules or fuel elements enclosed by a coolant tube and having yieldable retaining liner between the irradiation capsules and the coolant tube. For a hexagonal bundle surrounded by a hexagonal tube the yieldable retaining liner may consist either of six segments corresponding to the six sides of the tube or three angular segments each corresponding in two adjacent sides of the tube. The sides of adjacent segments abut and are so cut that metal-tometal contact is retained when the volume enclosed by the retaining liner is varied and Springs are provided for urging the segments toward the center of the tube to hold the capsules in a closely packed configuration. (Official Gazette)

  20. Irradiance gradients

    SciTech Connect

    Ward, G.J. Ecole Polytechnique Federale, Lausanne ); Heckbert, P.S. . School of Computer Science Technische Hogeschool Delft . Dept. of Technical Mathematics and Informatics)

    1992-04-01

    A new method for improving the accuracy of a diffuse interreflection calculation is introduced in a ray tracing context. The information from a hemispherical sampling of the luminous environment is interpreted in a new way to predict the change in irradiance as a function of position and surface orientation. The additional computation involved is modest and the benefit is substantial. An improved interpolation of irradiance resulting from the gradient calculation produces smoother, more accurate renderings. This result is achieved through better utilization of ray samples rather than additional samples or alternate sampling strategies. Thus, the technique is applicable to a variety of global illumination algorithms that use hemicubes or Monte Carlo sampling techniques.

  1. Genetic algorithm based active vibration control for a moving flexible smart beam driven by a pneumatic rod cylinder

    NASA Astrophysics Data System (ADS)

    Qiu, Zhi-cheng; Shi, Ming-li; Wang, Bin; Xie, Zhuo-wei

    2012-05-01

    A rod cylinder based pneumatic driving scheme is proposed to suppress the vibration of a flexible smart beam. Pulse code modulation (PCM) method is employed to control the motion of the cylinder's piston rod for simultaneous positioning and vibration suppression. Firstly, the system dynamics model is derived using Hamilton principle. Its standard state-space representation is obtained for characteristic analysis, controller design, and simulation. Secondly, a genetic algorithm (GA) is applied to optimize and tune the control gain parameters adaptively based on the specific performance index. Numerical simulations are performed on the pneumatic driving elastic beam system, using the established model and controller with tuned gains by GA optimization process. Finally, an experimental setup for the flexible beam driven by a pneumatic rod cylinder is constructed. Experiments for suppressing vibrations of the flexible beam are conducted. Theoretical analysis, numerical simulation and experimental results demonstrate that the proposed pneumatic drive scheme and the adopted control algorithms are feasible. The large amplitude vibration of the first bending mode can be suppressed effectively.

  2. TECHNOLOGY EVALUATION REPORT: SITE PROGRAM DEMONSTRATION TEST - ACCUTECH PNEUMATIC FRACTURING EXTRACTION AND HOT GAS INJECTION, PHASE 1 - VOLUME I

    EPA Science Inventory

    The Pneumatic Fracturing Extraction (PFE) process developed by Accutech Remedial Systems, Inc. makes it possible to use vapor extraction to remove volatile organics at increased rates from a broader range of vadose zones. The low permeability of silts, clays, shales, etc. would o...

  3. 77 FR 4996 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... Request Administrative Review, 76 FR 54735 (September 2, 2011). Guizhou Tyre Co., Ltd., Guizhou Advance... Antidumping and Countervailing Duty Administrative Reviews and Request for Revocation in Part, 76 FR 67133... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  4. 75 FR 22742 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of New Shipper...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... New Shipper Review, 74 FR 56575 (``Initiation Notice''). On March 22, 2009, OGF withdrew its request... Antidumping Duty New Shipper Review, 74 FR 31911 (July 6, 2009) (rescinding new shipper review after 60-day... International Trade Administration New Pneumatic Off-the-Road Tires From the People's Republic of...

  5. 78 FR 33059 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... Request Administrative Review, 77 FR 53863 (September 4, 2012). On September 28, 2012, and October 1, 2012... Reviews and Request for Revocation in Part, 77 FR 65858 (October 31, 2012). On December 10, 2012, Zhongce... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  6. 77 FR 26508 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Initiation of New...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-04

    ... Order, 73 FR 51624 (September 4, 2008). \\2\\ See Letter from TWS China entitled ``New Shipper Review... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China...-the-road tires (``tires'') from the People's Republic of China (``PRC''), received on March 30,...

  7. 75 FR 49459 - Certain New Pneumatic Off-The-Road Tires from the People's Republic of China: Notice of Amended...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-13

    ... the classification of the fifteen raw materials reported by Xugong as indirect materials. On August 4... materials as direct material inputs in the calculation of the normal value. As a result of this..., 73 FR 40485 (July 15, 2008) (``Final Determination''); Certain New Pneumatic Off-the-Road Tires...

  8. 78 FR 77101 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... from the People's Republic of China: Countervailing Duty Order, 73 FR 51627 (September 4, 2008). \\2\\ See Initiation of Five-Year (``Sunset'' ') Review, 78 FR 46575 (August 1, 2013). The regulations... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  9. 76 FR 14919 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Partial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ...; Opportunity to Request Administrative Review, 75 FR 53635 (September 1, 2010). On September 17, 2010, Mai... Administrative Reviews, 75 FR 66349 (October 28, 2010). Partial Rescission of Review Pursuant to 19 CFR 351.213(d... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  10. 76 FR 6603 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-07

    ... Administrative Reviews and Request for Revocation in Part, 74 FR 54956 (October 26, 2009). On October 19, 2010... China: Preliminary Results of Antidumping Duty Administrative Review, 75 FR 64259 (October 19, 2010... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  11. 75 FR 846 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Partial Rescission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ... Administrative Review, 74 FR 45179 (September 1, 2009). GPX timely requested an administrative review of the... Requests for Revocation in Part, 74 FR 54956 (October 26, 2009). Rescission, in Part, of Countervailing... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  12. 75 FR 73998 - Federal Motor Vehicle Safety Standards; New Pneumatic Tires for Motor Vehicles With a Gross...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-30

    ..., 2000 (65 FR 19477-78). Docket: For access to the docket to read background documents or comments..., 2010 (75 FR 60037, Docket No. NHTSA-2010-0132). In the NPRM, among other matters, NHTSA proposed to... Vehicle Safety Standards; New Pneumatic Tires for Motor Vehicles With a Gross Vehicle Weight Rating...

  13. The Petrocarb pneumatic feeding system: A proven method for feeding particulate solids at controlled rates. [for coal gasification systems

    NASA Technical Reports Server (NTRS)

    Reintjes, H.

    1977-01-01

    An outline of the principal features of the Petrocarb Pneumatic Feeding System is given. Early development and various commercial applications are included. It is concluded that the Petrocarb Injection System is capable of feeding dry solids into most of the processes being developed for utilizing coal.

  14. Gastric Perforation by Ingested Rabbit Bone Fragment

    PubMed Central

    Gambaracci, Giulio; Mecarini, Eleonora; Franceschini, Maria Silvia; Scialpi, Michele

    2016-01-01

    The majority of accidentally ingested foreign bodies is excreted from the gastrointestinal (GI) tract without any complications. Sometimes sharp foreign bodies – like chicken and fish bones – can lead to intestinal perforation and may present insidiously with a wide range of symptoms and, consequently, different diagnoses. We report the case of a 59-year-old woman presenting with fever and a 1-month history of vague abdominal pain. Computed tomography (CT) showed the presence of a hyperdense linear image close to the gastric antrum surrounded by a fluid collection and free peritoneal air. At laparotomy, a 4-cm rabbit bone fragment covered in inflamed tissue was detected next to a gastric wall perforation. Rabbit bone fragment ingestion, even if rarely reported, should not be underestimated as a possible cause of GI tract perforation. PMID:27403113

  15. Postcranial skeletal pneumaticity: a case study in the use of quantitative microCT to assess vertebral structure in birds.

    PubMed

    Fajardo, R J; Hernandez, E; O'Connor, P M

    2007-07-01

    Limb elements in birds have been characterized as exhibiting a reduction in trabecular bone, thinner cortices and decreased bending strength when pneumatized, yet it is unclear if these characteristics generalize to the axial skeleton. Thin section techniques, the traditional gold standard for bone structure studies, have most commonly been applied to the study of avian bone. This destructive technique, however, makes it subsequently impossible to use the same samples in experimental testing systems that allow researchers to correlate structure with the mechanical properties of the bone. Micro-computed tomography (microCT), a non-destructive X-ray imaging technique, can be used to assess the effect of pneumatization on vertebral cortical and trabecular bone through virtual extraction and structural quantification of each tissue type. We conducted a preliminary investigation of the application of microCT methods to the study of cortical and trabecular bone structure in a small sample of pneumatic and apneumatic thoracic vertebrae. The sample consisted of two similar-sized anatids, Aix sponsa (n = 7) and Oxyura jamaicensis (n = 5). Volumes of interest were created that contoured (outlined) the boundaries of the ventral cortical bone shell, the trabecular compartment and the whole centrum (cortical bone + trabecular bone), and allowed independent structural analysis of each volume of interest. Results indicated that bone volume fraction of the whole centrum was significantly higher in the apneumatic O. jamaicensis than in the pneumatized A. sponsa (A. sponsa = 36%, O. jamaicensis = 48%, P < 0.05). In contrast, trabecular bone volume fraction was similar between the two species. The ventral cortical bone shell was approximately 23% thinner (P < 0.05) in A. sponsa (0.133 mm) compared with apneumatic O. jamaicensis (0.172 mm). This case study demonstrates that microCT is a powerful non-destructive imaging technique that may be applied to the three-dimensional study of

  16. Postcranial skeletal pneumaticity: a case study in the use of quantitative microCT to assess vertebral structure in birds

    PubMed Central

    Fajardo, R J; Hernandez, E; O’Connor, P M

    2007-01-01

    Limb elements in birds have been characterized as exhibiting a reduction in trabecular bone, thinner cortices and decreased bending strength when pneumatized, yet it is unclear if these characteristics generalize to the axial skeleton. Thin section techniques, the traditional gold standard for bone structure studies, have most commonly been applied to the study of avian bone. This destructive technique, however, makes it subsequently impossible to use the same samples in experimental testing systems that allow researchers to correlate structure with the mechanical properties of the bone. Micro-computed tomography (µCT), a non-destructive X-ray imaging technique, can be used to assess the effect of pneumatization on vertebral cortical and trabecular bone through virtual extraction and structural quantification of each tissue type. We conducted a preliminary investigation of the application of µCT methods to the study of cortical and trabecular bone structure in a small sample of pneumatic and apneumatic thoracic vertebrae. The sample consisted of two similar-sized anatids, Aix sponsa (n = 7) and Oxyura jamaicensis (n = 5). Volumes of interest were created that contoured (outlined) the boundaries of the ventral cortical bone shell, the trabecular compartment and the whole centrum (cortical bone + trabecular bone), and allowed independent structural analysis of each volume of interest. Results indicated that bone volume fraction of the whole centrum was significantly higher in the apneumatic O. jamaicensis than in the pneumatized A. sponsa (A. sponsa = 36%, O. jamaicensis = 48%, P < 0.05). In contrast, trabecular bone volume fraction was similar between the two species. The ventral cortical bone shell was approximately 23% thinner (P < 0.05) in A. sponsa (0.133 mm) compared with apneumatic O. jamaicensis (0.172 mm). This case study demonstrates that µCT is a powerful non-destructive imaging technique that may be applied to the three-dimensional study of avian bone

  17. Neutralization of pathophysiological manifestations of Russell's viper envenoming by antivenom raised against gamma-irradiated toxoid.

    PubMed

    Mandal, M; Hati, R N; Hati, A K

    1993-02-01

    Rabbits were immunized against gamma-irradiated (100 krads) Russell's viper venom toxoid adsorbed to aluminium phosphate gel. The antivenom (0.1 ml) neutralized 5 LD50, 8 minimum hemorrhagic doses (MHD) and 14 minimum necrotic doses (MND) of venom. The coagulant and protease activities of the viper venom were neutralized more effectively than phospholipase A activity, by the toxoid antivenom. PMID:8456449

  18. Outbreak of rabbit hemorrhagic disease in domestic lagomorphs.

    PubMed

    Campagnolo, Enzo R; Ernst, Mark J; Berninger, Mary L; Gregg, Douglas A; Shumaker, Thomas J; Boghossian, Aida M

    2003-10-15

    Rabbit hemorrhagic disease (RHD) was diagnosed in domestic lagomorphs on a rabbit farm in Illinois. Clinical signs of RHD in affected rabbits included signs of depression, anorexia, fever, paddling, convulsions, and sudden death. Findings of necropsies and histologic evaluations of specimens of liver and spleen were indicative of RHD. In liver specimens obtained from dead rabbits, RHD viral antigen was detected via hemagglutination assay and viral antigen-detection ELISA. The source of the outbreak was traced to a rabbitry in Utah. As the disease spread, the outbreak involved rabbits in various regions of the United States; > 4,800 rabbits were euthanatized and buried as a result of the depopulation effort in several states. The economic impact of the disease can be considerable; if the disease is suspected, it is imperative that the appropriate state or federal veterinarian's office be contacted immediately. PMID:14584745

  19. Carbon tetrachloride-induced liver injury in the rabbit.

    PubMed Central

    Bernacchi, A. S.; de Castro, C. R.; de Ferreyra, E. C.; Villarruel, M. C.; Fernández, G.; de Fenos, O. M.; Castro, J. A.

    1983-01-01

    CCl4 administration to rabbits leads to early destruction of liver microsomal cytochrome P-450, to depression of glucose 6 phosphatase, to ultrastructurally revealable alterations and to an intense necrosis and fat accumulation in liver. Despite the known resistance of rabbit liver microsomes to lipid peroxidation, CCl4 administration to rabbits promoted lipid peroxidation of their liver microsomal lipids as revealable by the diene hyperconjugation technique, at periods of time from 1 to 12 h. Nevertheless, the intensity of this process is not equivalent to that occurring in rat liver microsomes, since the arachidonic acid content of rabbit liver microsomal lipids does not decrease at either 6 or 24 h after CCl4 administration. Rabbit liver is able to activate CCl4 to reactive metabolites that bind covalently to lipids. Relevance of covalent binding of CCl4 reactive metabolites and CCl4-promoted lipid peroxidation to CCl4-induced rabbit liver injury is analysed. Images Fig. 1 Fig. 2 PMID:6309207

  20. Alanine transport across in vitro rabbit vagina.

    PubMed

    Hajjar, J J; Mroueh, A M

    1979-04-01

    Transmural flux of alanine across the vaginal epithelium of the rabbit is a specialized mechanism. There is a net serosal to mucosal translocation of the amino acid in the absence of a concentration gradient. Changes in reproductive cycle do not influence this mechanism but, in castrated animals, it is abolished. Transport properties of vaginal epithelium is important because of increasing utilization of intravaginal contraceptives. PMID:455986