  1. Power lines harmonic radiation in circumterrestrial space

    NASA Astrophysics Data System (ADS)

    Pronenko, Vira; Korepanov, Valery; Dudkin, Denis

    2014-05-01

    Currently, one of the main areas in the near-Earth space research is the space weather exploration and forecasting. This study mainly relates to solar activity influence on the ionosphere and the Earth's atmosphere (i.e., the energy transfer in the direction of the Sun-magnetosphere-ionosphere-atmosphere-surface of the Earth) and does not reflect a significant impact of the powerful natural and anthropogenic processes, which occur on the Earth's surface and influence on the atmosphere-ionosphere-magnetosphere chain. The powerful sources and consumers of electrical energy (radio transmitters, power plants, power lines and industrial objects) cause different ionospheric phenomena, for example, changes of the electromagnetic (EM) field and plasma in the ionosphere, and affect on the state of the Earth atmosphere. Anthropogenic EM effects in the ionosphere are already observed by the scientific satellites. Consequences of anthropogenic impacts on the ionosphere are not currently known. Therefore, it is very important and urgent task to conduct the statistically significant research of the ionospheric parameters variations due to the influence of the powerful man-made factors, primarily owing to substantial increase of the EM energy production. Naturally, the satellite monitoring of the ionosphere and magnetosphere in the frequency range from tens of hertz to tens of MHz with wide ground support offers the best opportunity to observe the EM energy release, both in the global and local scales. The available experimental data, as well as theoretical estimations, allow with a high degree of certainty to say that the permanent satellite monitoring of the ionospheric and magnetospheric anthropogenic EM perturbations can be used for: a) objective assessment and prediction of the space weather conditions; b) evaluation of the daily or seasonal changes in the level of energy consumption; c) construction of a map for estimation of near space EM pollution. The examples of power

  2. Power line harmonic radiation observed by the DEMETER spacecraft at 50/60 Hz and low harmonics

    NASA Astrophysics Data System (ADS)

    Němec, F.; Parrot, M.; Santolík, O.

    2015-10-01

    We present a low-altitude satellite survey of Power Line Harmonic Radiation (PLHR), i.e., electromagnetic waves radiated by electric power systems on the ground. We focus on frequencies corresponding to the first few harmonics of the base power system frequencies (50 Hz or 60 Hz, depending on the region). It is shown that the intensities of electromagnetic waves detected at these frequencies at an altitude of about 700 km are significantly enhanced above industrialized areas. The frequencies at which the wave intensities are increased are in excellent agreement with base power system frequencies just below the satellite location. We also investigate a possible presence of the weekend effect, i.e., if the situation is different during the weekends when the power consumption is lower than during the weekdays. Such an effect might be possibly present in the European region, but it is very weak. PLHR effects are less often detected in the summer, as the ionospheric absorption increases, and also, the radiation is obscured by lightning generated emissions. This difference is smaller in the U.S. region, in agreement with the monthly variations of the power consumption. The analysis of the measured frequency spectra reveals that although intensity increases at low odd harmonics of base power system frequencies are routinely detected, low even harmonics are generally absent. Finally, we verify the relation of PLHR intensities to the geomagnetically induced currents (GICs) proxy. It is shown that the PLHR intensity is increased at the times of higher GIC proxy values during the night.

  3. Harmonic and power factor correction by means of active line conditioners with adaptive estimation control

    SciTech Connect

    Ashton, R.W.

    1991-01-01

    Due to the proliferation of power electronic devices in recent years, the amount of harmonic current injected into power systems is on the increase causing undesirable voltage waveform distortion. A new type of versatile Active Power Line Conditioner able to supply a DC load while generating useful harmonics which help reduce the voltage distortion at the connected bus was designed, built and analyzed. The optimum design was obtained by means of an economic study that considers the power loss, the cost of an RFI filter and the effect of the switching rate. An adaptive methodology, requiring only knowledge of the bus voltage distortion, was developed and applied to adjust the amplitudes and phase angles of the injected harmonic currents. This novel approach is based on reducing the voltage Total Harmonic Distortion by minimizing the individual harmonic voltages in an error signal using a gradient method. Through successive adjustments, the difference between the actual bus voltage and the desired bus voltage is minimized. The proposed method can be successfully applied in low and medium voltage networks with multiple nonlinear loads scattered among linear loads.

  4. Removal of power-line harmonics from proton magnetic resonance measurements

    NASA Astrophysics Data System (ADS)

    Legchenko, Anatoly; Valla, Pierre

    2003-08-01

    The Magnetic Resonance Sounding (MRS) method is based on the resonance behaviour of proton magnetic moments in the geomagnetic field. The main distinction between MRS and other geophysical methods is that it measures the magnetic resonance signal directly from groundwater molecules, making it a selective tool sensitive to groundwater. As the signal generated by the protons is very small, the method is also sensitive to electromagnetic interference (noise) and this is one of the major limitations for practical application. The frequency of the magnetic resonance signal (the Larmor frequency) is directly proportional to the magnitude of the geomagnetic field and varies between 800 and 2800 Hz around the globe. Whilst natural noise within this frequency range is generally not very large (excepting magnetic storms or other temporary disturbances), the level of cultural noise (electrical power lines, generators, etc.) may be very high. In order to improve performance, three existing filtering techniques were adapted to processing MRS measurements: block subtraction, sinusoid subtraction and notch filtering. The first two are subtraction techniques capable of suppressing stationary power-line noise without distorting or attenuating the signal of interest, both involve subtracting an estimate of the harmonic component but differ in the way the component is estimated. The block subtraction method consists of ascertaining the power-line noise (or "noise block") from a record of the noise alone, and then subtracting this block from a record containing both the noise and the signal. The sinusoid subtraction method is based on the calculation of the amplitude, frequency and phase of power-line harmonics using noise records. The notch filtering method does not require knowledge of the power-line harmonic parameters but it may cause distortion of the measured signal. During the study, it was found that, in the investigated frequency range, the electromagnetic noise produced by

  5. High-Harmonic Fast-Wave Power Flow Along Magnetic Field Lines in the Scrape-Off Layer of NSTX

    SciTech Connect

    Perkins, R. J.; Hosea, J.; Kramer, G.; Ahn, Joonwook; Bell, R. E.; Diallo, A.; Gerhardt, S.; Gray, T. K.; Green, David L; Jaeger, Erwin Frederick; Jaworski, M. A.; LeBlanc, B; McLean, Adam G; Maingi, Rajesh; Phillips, C. K.; Roquemore, L.; Ryan, Philip Michael; Sabbagh, S. A.; Taylor, G.; Wilson, J. R.

    2012-01-01

    A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

  6. High-harmonic fast-wave power flow along magnetic field lines in the scrape-off layer of NSTX.

    PubMed

    Perkins, R J; Hosea, J C; Kramer, G J; Ahn, J-W; Bell, R E; Diallo, A; Gerhardt, S; Gray, T K; Green, D L; Jaeger, E F; Jaworski, M A; LeBlanc, B P; McLean, A; Maingi, R; Phillips, C K; Roquemore, L; Ryan, P M; Sabbagh, S; Taylor, G; Wilson, J R

    2012-07-27

    A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive. PMID:23006093

  7. Observations of power line harmonic radiation by the low-altitude AUREOL 3 satellite

    SciTech Connect

    Parrot, M.

    1994-03-01

    This paper presents observations of very low frequency radiation in the lower part of the ionosphere from a polar orbiting satellite at low latitudes. It was able to record several observation of low frequency radiation which is very close to a harmonic of the 50 Hz line frequency. The frequency is observed to drift in time, from 1 to 8 Hz/sec. They are not sure how to account for this apparent non-linear coupling of these very low frequency waves into the ionosphere.

  8. Fetal ECG Extraction from Abdominal Signals: A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

    PubMed Central

    Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner

    2014-01-01

    Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state. Many signal processing methods for cancelling the PLI from biopotentials are available in the literature. In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices. PMID:24660020

  9. On-line tracking of changing harmonics in stressed power systems: Applications to Hydro-Quebec network

    SciTech Connect

    Kamwa, I.; Grondin, R.; McNabb, D.

    1996-10-01

    This paper applies to a practical test case two schemes for determining harmonics in power systems that are not limited to stationary waveforms, but can equally estimate harmonic phasors in waveforms with time-varying amplitudes and changing fundamental frequency. The first scheme relies on the short-time Fourier analysis performed using the Fast Fourier Transform (FFT) with time-domain windowing and frequency-domain interpolation. Another scheme combines fundamental-frequency tracking with a Kalman filter based harmonic analyzer, yielding a uniformly sampled, self-synchronizing harmonics tracker. The performance of these advanced measurement schemes for changing harmonics is illustrated convincingly on nonstationary waveforms generated in the EMTP using a realistic series-compensated transmission network.

  10. High Power Amplifier Harmonic Output Level Measurement

    NASA Technical Reports Server (NTRS)

    Perez, R. M.; Hoppe, D. J.; Khan, A. R.

    1995-01-01

    A method is presented for the measurement of the harmonic output power of high power klystron amplifiers, involving coherent hemispherical radiation pattern measurements of the radiated klystron output. Results are discussed for the operation in saturated and unsaturated conditions, and with a waveguide harmonic filter included.

  11. Power Factor Correction to Mitigate Harmonic Distortion

    NASA Astrophysics Data System (ADS)

    Kochetkov, Gary

    Many direct current (DC) devices must receive their power from the alternating current (AC) grid. Rectifiers use diodes to create DC for these devices. Due to diodes' non-linear nature however, harmonics are created and these travel back into the grid. A significant presence of harmonics causes component heating and possible malfunction. A harmonic mitigation procedure is needed. With the correct usage of transistors, the current drawn by a rectifier can be manipulated to remove almost all harmonics. This process is called power factor correction (PFC), and formally acts to reduce the total harmonic distortion (THD) of the current. To investigate this, a three phase active rectifier was computer simulated and a controller was designed to provide switching signals for the transistors. Finally, the device was constructed in the laboratory to drive a DC motor, verifying its operating principle outside of the idealities of simulation.

  12. Harmonics in a Wind Power Plant: Preprint

    SciTech Connect

    Preciado, V.; Madrigal, M.; Muljadi, E.; Gevorgian, V.

    2015-04-02

    Wind power generation has been growing at a very fast pace for the past decade, and its influence and impact on the electric power grid is significant. As in a conventional power plant, a wind power plant (WPP) must ensure that the quality of the power being delivered to the grid is excellent. At the same time, the wind turbine should be able to operate immune to small disturbances coming from the grid. Harmonics are one of the more common power quality issues presented by large WPPs because of the high switching frequency of the power converters and the possible nonlinear behavior from electric machines (generator, transformer, reactors) within a power plant. This paper presents a summary of the most important issues related to harmonics in WPPs and discusses practical experiences with actual Type 1 and Type 3 wind turbines in two WPPs.

  13. Power Divider for Waveforms Rich in Harmonics

    NASA Technical Reports Server (NTRS)

    Sims, William Herbert, III

    2005-01-01

    A method for dividing the power of an electronic signal rich in harmonics involves the use of an improved divider topology. A divider designed with this topology could be used, for example, to propagate a square-wave signal in an amplifier designed with a push-pull configuration to enable the generation of more power than could be generated in another configuration.

  14. Power System Harmonic Elimination to Improve Power Quality

    NASA Astrophysics Data System (ADS)

    Chandrasekaran, K.; Ramachandaramurthy, V. K.

    2015-06-01

    An improvised RLC interface filter for a Dynamic Voltage Restorer (DVR) is proposed. The RLC filter is connected in the front end between the IGBT based Voltage Source Inverter (VSI) and the injection transformer and is able to eliminate voltage harmonics in the system and also switching harmonics generated from VSI. The voltage at the sensitive load end is pure sinusoidal. In this method, the DVR produced Pulse Width Modulation (PWM) voltage with voltage harmonic canceling the voltage harmonic generated from the supply main. The VSI handles harmonic power. The low order switching harmonics generated by the IGBT based VSI is suppressed. The DVR has greater voltage injection capability. Good dynamic and transient results recorded and Total Harmonic Distortion (THD) at the sensitive load end is minimized. The voltage at the sensitive load is sinusoidal and at 1.0 pu. PSCAD/EMTDC is used to validate the performance of the interface filter and the DVR. Simulated results are presented.

  15. Birds on power lines

    NASA Astrophysics Data System (ADS)

    Arnaldo Redinz, José

    2014-07-01

    Why can a bird safely rest on a high-voltage power line? We discuss three effects that can lead to the development of voltages and currents in the bird's body. To explain the absence of electric shocks, we give numerical estimates of these voltages and currents obtained from the standard solution for the voltage along a two-wire transmission line.

  16. Power line detection system

    DOEpatents

    Latorre, Victor R.; Watwood, Donald B.

    1994-01-01

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard.

  17. Power line detection system

    DOEpatents

    Latorre, V.R.; Watwood, D.B.

    1994-09-27

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard. 4 figs.

  18. Harmonics of 60 Hz in power systems caused by geomagnetic disturbances. [Manitoba

    NASA Technical Reports Server (NTRS)

    Hayashi, K.; Oguti, T.; Watanabe, T.; Tsuruda, K.; Kokubun, S.; Horita, R. E.

    1979-01-01

    Simultaneous VLF/ULF observations carried out near Winnipeg, Manitoba show that geomagnetic disturbances control the behavior of harmonics of 60 Hz man-made electric power. The harmonics of 60 Hz detected by the VLF receiver are at multiples of 180 Hz, indicating that they originated from a 3 phase ac power system. Under geomagnetically quiet conditions, only odd harmonics of 70 Hz were detected. In disturbed conditions, both odd and even harmonics were excited. The strength of each harmonic changed concurrently with geomagnetic pulsation (ULF) activity. These findings seem to indicate that a portion of telluric currents shunted into the power line system through the neutrals of the Y-connected transformers give rise to a dc bias to the transformer core materials and that it distorts their hysteresis loops, activating harmonics of 60 Hz power. A mathematical proof is given that a hysteresis loop having a point of symmetry generates odd harmonics only, whereas loops lacking in point-symmetry generally give rise to both odd and even harmonics. A general formula was obtained to calculate the strength of each harmonic based on the shape of the hysteresis loop.

  19. A new method for both harmonic voltage and harmonic current suppression and power factor correction in industrial power systems

    SciTech Connect

    Cheng, H.; Sasaki, Hiroshi; Yorino, Naoto

    1995-12-31

    This paper proposes a new method for designing a group of single tuned filters for both harmonic current injection suppression and harmonic voltage distortion reduction and power factor correction. The proposed method is based on three purposes: (1) reduction of harmonic voltage distortion in the source terminals to an acceptable level, (2) suppression of harmonic current injection in the source terminals to an acceptable level, (3) improvement of power factor at the source terminals. To determine the size of the capacitor in a group of single tuned filters, three new NLP mathematical formulations will be introduced. The first is to suppress harmonic current injection within an acceptable level. The second is to minimize the fundamental reactive power output while reducing harmonic voltage distortion to an acceptable level. The third is to determine an optimal assignment of reactive power output based on the results of harmonic voltage reduction and power factor correction. This new method has been demonstrated for designing a group of single tuned filters and its validity has been successfully confirmed through numerical simulation in a 35 KV industrial power system. The proposed method can efficiently provide an optimal coordination in a group of single tuned filters relating to suppressing harmonic current injection, reducing harmonic voltage distortion and improving power factor.

  20. Harmonic analysis of spacecraft power systems using a personal computer

    NASA Technical Reports Server (NTRS)

    Williamson, Frank; Sheble, Gerald B.

    1989-01-01

    The effects that nonlinear devices such as ac/dc converters, HVDC transmission links, and motor drives have on spacecraft power systems are discussed. The nonsinusoidal currents, along with the corresponding voltages, are calculated by a harmonic power flow which decouples and solves for each harmonic component individually using an iterative Newton-Raphson algorithm. The sparsity of the harmonic equations and the overall Jacobian matrix is used to an advantage in terms of saving computer memory space and in terms of reducing computation time. The algorithm could also be modified to analyze each harmonic separately instead of all at the same time.

  1. Efficient millimeter wave 1140 GHz/ diode for harmonic power generation

    NASA Technical Reports Server (NTRS)

    1967-01-01

    Epitaxial gallium arsenide diode junction formed in a crossed waveguide structure operates as a variable reactance harmonic generator. This varactor diode can generate power efficiently in the low-millimeter wavelength.

  2. High power operation of first and second harmonic gyrotwystrons

    SciTech Connect

    Lawson, W.; Latham, P.E.; Calame, J.P.; Cheng, J.; Hogan, B.; Nusinovich, G.S.; Irwin, V.; Granatstein, V.L.; Reiser, M.

    1995-07-01

    We report the first experimental operation of overmoded first and second harmonic gyrotwystron amplifier configurations. Both devices utilize a single cavity which is driven near 9.87 GHz in the TE{sub 011} mode, heavily attenuated drift tubes, and long tapered output waveguide sections. A magnetron injection gun produces a 460 kV, 245 A beam with a maximum average perpendicular-to-parallel velocity ratio approximately equal to one. The axial magnetic field profile is sharply tapered in the output section. Peak powers above 21 MW are achieved in 1 {mu}s pulses with an efficiency exceeding 22% and a large signal gain near 24 dB in the first harmonic tube. The second harmonic tube achieves nearly 12 MW of the peak power with an efficiency of 11% and a gain above 21 dB. First harmonic amplifier performance is limited principally by competition from a fundamental mode output waveguide interaction; the second harmonic tube is limited by both travelling wave output modes and by a down-taper oscillation. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  3. Analysis of the harmonics and power-factor effects at a utility-intertied photovoltaic system

    SciTech Connect

    Campen, G.L.

    1982-01-01

    Outlined are the harmonics and power-factor characteristics and effects of a single residential photovoltaic (PV) installation using a line-commutated inverter. The data were taken during a five-day measurement program conducted at the John F. Long House, which is a prototype residential PV installation located in Phoenix, Arizona. The magnitude and phase of various currents and voltages from the fundamental to the 13th harmonic were recorded both with and without the operation of the PV system. A candidate method of modeling the installation for computer studies of larger concentrations is given.

  4. An analysis of the harmonics and power factor effects at a utility intertied photovoltaic system

    SciTech Connect

    Campen, G.L.

    1982-12-01

    This paper outlines the harmonics and power-factor characteristics and effects of a single residential photovoltaic (PV) installation using a line-commutated inverter. The data were taken during a five-day measurement program conducted at the John F. Long House, which is a prototype residential PV installation located in Phoenix, Arizona. The magnitude and phase of various currents and voltages from the fundamental to the 13th harmonic were recorded both with and without the operation of the PV system. A candidate method of modeling the installation for computer studies of larger concentrations is given.

  5. Conservation with underground power lines

    SciTech Connect

    Graneau, P.

    1980-01-01

    The following aspects of underground power transmission lines are discussed: their contribution to area beautification; line losses and their causes; the energy conservation potential of large-conductor underground cables; reliability and outage advantages as compared with overhead lines; the history of underground systems; problems with polyethylene insulation; and the development and performance of sodium conductors for underground cables. (LCL)

  6. High gain amplifiers: Power oscillations and harmonic generation

    SciTech Connect

    Dattoli, G.; Ottaviani, P. L.; Pagnutti, S.

    2007-08-01

    We discuss the power oscillations in saturated high gain free electron laser amplifiers and show that the relevant period can be written in terms of the gain length. We use simple arguments following from the solution of the pendulum equation in terms of Jacobi elliptic functions. Nontrivial effects due to nonlinear harmonic generation and inhomogeneous broadening are discussed too, as well as the saturated dynamics of short pulses.

  7. Harmonic Resonance Analysis for PEP II Power Factor Control Upgrades

    NASA Astrophysics Data System (ADS)

    Corvin, C.

    1997-05-01

    Recent upgrades to the high voltage utility distribution network at the Stanford Linear Accelerator Center have been accompanied by the installation of a large number of power supplies associated with the PEP-II B Factory project. These power supplies include a diverse assortment of single and three phase units, in two, six and twelve pulse configurations, with chopped, pulsed and continuous loading. Viewed as harmonic power sources in a range from a hundred to several kilohertz, they have the potential to be in resonance with the utility system network, a condition to be avoided. This paper analyzes and evaluates these resonance conditions with a view toward adding electric power factor correction upgrades to achieve substantial cost savings associated with power factor penalty avoidance. Similar studies and upgrades at SLAC in the past have reduced electric power costs over time by several hundred thousand dollars, thus providing the incentive to evaluate the recent upgrades to the PEP-II utility network.

  8. Discussions and Comparisons between Comprehensive Harmonic Detection and Specific Harmonic Detection in a Shunt Active Filter for Installation on a Power Distribution System

    NASA Astrophysics Data System (ADS)

    Yamashita, Hiroshi; Pichai, Jintakosonwit; Fujita, Hideaki; Akagi, Hirofumi; Shinohara, Junya

    This paper deals with harmonic voltage detection methods for a shunt active filter intended for installation on a power distribution system. The active filter acts as a resistor to damp out harmonic propagation throughout the power distribution system. However, the active filter may fall into an unstable condition, because the control system forms a complex feedback loop including harmonic detection, current control, and system impedance. Stability and harmonic-damping performance of two different harmonic detection methods, that are comprehensive harmonic detection and specific harmonic detection, are compared with each other. Moreover, a new compensation scheme for the comprehensive harmonic detection method is proposed to improve system stability.

  9. Collaboration across the Power Line.

    ERIC Educational Resources Information Center

    Romer, Karen T.; Whipple, William R.

    1991-01-01

    The college student who participates in genuine collaboration with a faculty member in an intellectual endeavor transcends the barrier of power. Once it has been breached, other power lines will be less constraining. The experience transforms the nature of learning and constructs a lasting authority in the student. (MSE)

  10. Wide Band Power and Harmonic Amplitude of Five Precipitation Sets

    NASA Astrophysics Data System (ADS)

    Ruane, A. C.; Roads, J. O.

    2006-12-01

    Time series of precipitation from three high resolution precipitation products (TRMM 3B-42, CMORPH, and PERSIANN) and two reanalysis models (the NCEP/NCAR Reanalysis-2 and an ECPC Seasonal Forecast Model reanalysis) are examined for their frequency characteristics using both harmonic and Fourier approaches. Power spectra generated by fast-Fourier transforms are divided into wide bands comprising the low-frequency (period greater than 30 days), synoptic (period between 2 30 days), and high-frequency (period less than 2 days) components. Low-frequency variability is generally the weakest component, but is amplified over the Inter-Tropical Convergence Zone and monsoonal regions. Land areas feature enhanced high- frequency variability and reduced synoptic variability in comparison to the surrounding oceans. The diurnal and semidiurnal harmonics explain very little of the variance, suggesting that the harmonic approach does a poor job of capturing the high-frequency variability of the datasets. Inter-product and inter-model differences also indicate biases of the precipitation product algorithms and convective parameterizations, including a strong bias toward low-frequency variability in the Relaxed Arakawa-Schubert parameterization employed by the ECPC Seasonal Forecast Model, as well as increased high-frequency power in the TRMM 3B-42 product.

  11. Power line carrier interference from HVDC converter terminals

    SciTech Connect

    Tatro, P.J.; Adamson, K.A. ); Eitzmann, M.A.; Smead, M. . Power Systems Engineering Dept.)

    1993-07-01

    Power line carrier (PLC) equipment typically operates in the frequency range from 25 kHz to 300 kHz. Interference studies for HVDC converters usually concentrate on interference from noise sources within this frequency range. However, operating experience at the Sandy Pond converter terminal has indicated that PLC equipment is also susceptible to interference from sources of power system harmonics below the PLC frequency range. Extensive field testing and analytical studies have shown that each PLC circuit has a resonant frequency below the operating frequency. If excited at this resonant frequency, high voltages may exist within the PLC circuit. The resulting saturation of PLC components leads to local generation of radio frequency (RF) noise that interferes with proper operation of PLC circuits. Sources of power system harmonics in the 3-10 kHz range, such as line commutated dc converters, are potential sources of this type of interference.

  12. Advanced configuration of hybrid passive filter for reactive power and harmonic compensation.

    PubMed

    Kececioglu, O Fatih; Acikgoz, Hakan; Sekkeli, Mustafa

    2016-01-01

    Harmonics is one of the major power quality problems for power systems. The harmonics can be eliminated by power filters such as passive, active, and hybrid. In this study, a new passive filter configuration has been improved in addition to the existing passive filter configurations. Conventional hybrid passive filters are not successful to compensate rapidly changing reactive power demand. The proposed configure are capable of compensating both harmonics and reactive power at the same time. Simulation results show that performance of reactive power and harmonic compensation with advanced hybrid passive filter is better than conventional hybrid passive filters. PMID:27536512

  13. Detection of first harmonic of cyclotron line in Be/X-ray binary pulsar Cep X-4

    NASA Astrophysics Data System (ADS)

    Jaisawal, Gaurava K.; Naik, Sachindra

    2016-07-01

    We present broad-band spectral properties of the high mass X-ray binary pulsar Cep X-4 by using a Suzaku observation, performed during the decline phase of outburst in 2014 July. The pulsation period of the pulsar was estimated to be 66.3 s during the observation. Soft X-ray pulse profile of the pulsar was found to be double peaked which evolved into a single peaked pulse profile at higher energies. The 1-70 keV energy spectrum of the pulsar was well described with several continuum models such as partial covering Negative and Positive power-law with Exponential cut-off (NPEX), high-energy cut-off power-law and CompTT models. Additional components such as a cyclotron absorption line at ˜28 keV and two Gaussian functions for 6.4 and 6.9 keV iron emission lines were required to describe the the observed features in the spectrum. An additional absorption like feature was also detected in the pulsar spectrum at ˜45 keV. This feature was found to be model independent and was detected with >4 sigma confidence level. We identified this additional feature as the first harmonic of the fundamental cyclotron line at 28 keV. The energy ratio between first cyclotron harmonic and fundamental line was found to be lower (1.7) than the conventional factor of 2. This indicates that the line forming regions are at different heights or viewed at large angles. Phase-resolved spectroscopy was performed to understand the changes in the cyclotron line parameters with pulsar phases. The fundamental and first cyclotron harmonic line parameters show a significant variation with pulse phase. This can be explained as the effects of the viewing angle or the role of complicated magnetic field of the neutron star.

  14. Measurement of Oxygen A Band Line Parameters by Using Modulation Spectroscopy with Higher Harmonic Detection

    NASA Technical Reports Server (NTRS)

    Dharamsi, Amin

    1999-01-01

    Wavelength modulation spectroscopy is used to demonstrate that extremely weak absorption lines can be measured even when these lines suffer from interference from the wings of adjacent stronger lines. It is shown that the use of detection at several harmonics allows such interference to be examined clearly and conveniently. The results of experimental measurements on a weak magnetic dipole driven, spin-forbidden line in the oxygen A band, which experiences interference from the wings of a pair of adjacent lines towards the blue and red regions of line center, are presented. A comparison of the experimental results to theory is given.

  15. Multi-harmonic measurements of line shape under low absorption conditions

    NASA Astrophysics Data System (ADS)

    Lan, L. J.; Ding, Y. J.; Peng, Z. M.; Du, Y. J.; Liu, Y. F.; Li, Z.

    2014-06-01

    We propose a method that employs the ratios of the 2nd and 4th harmonics at the line center to measure line shape under low absorption conditions. To verify this method, the transition of CO2 at 6,982.0678 cm-1 is selected to measure line shape by using the proposed method and direct absorption spectroscopy in laboratory conditions. The results from both methods have a high degree of consistency. This satisfactory agreement indicates the validity of the proposed method.

  16. Compensation for Harmonic Currents and Reactive Power in Wind Power Generation System using PWM Inverter

    NASA Astrophysics Data System (ADS)

    Shinohara, Katsuji; Shinhatsubo, Kurato; Iimori, Kenichi; Yamamoto, Kichiro; Saruban, Takamichi; Yamaemori, Takahiro

    In recent year, consciousness of environmental problems is enhancing, and the price of the electric power purchased by an electric power company is established expensive for the power plant utilizing the natural energy. So, the introduction of the wind power generation is promoted in Japan. Generally, squirrel-cage induction machines are widely used as a generator in wind power generation system because of its small size, lightweight and low-cost. However, the induction machines do not have a source of excitation. Thus, it causes the inrush currents and the instantaneous voltage drop when the generator is directly connected to a power grid. To reduce the inrush currents, an AC power regulator is used. Wind power generations are frequently connected to and disconnected from the power grid. However, when the inrush currents are reduced, harmonic currents are caused by phase control of the AC power regulator. And the phase control of AC power regulator cannot control the power factor. Therefore, we propose the use of the AC power regulator to compensate for the harmonic currents and reactive power in the wind power generation system, and demonstrate the validity of its system by simulated and experimental results.

  17. Thermal optimization of second harmonic generation at high pump powers.

    PubMed

    Sahm, Alexander; Uebernickel, Mirko; Paschke, Katrin; Erbert, Götz; Tränkle, Günther

    2011-11-01

    We measure the temperature distribution of a 3 cm long periodically poled LiNbO₃ crystal in a single-pass second harmonic generation (SHG) setup at 488 nm. By means of three resistance heaters and directly mounted Pt100 sensors the crystal is subdivided in three sections. 9.4 W infrared pump light and 1.3 W of SHG light cause a de-homogenized temperature distribution of 0.2 K between the middle and back section. A sectional offset heating is used to homogenize the temperature in those two sections and thus increasing the conversion efficiency. A 15% higher SHG output power matching the prediction of our theoretical model is achieved. PMID:22109182

  18. National Maglev initiative: California line electric utility power system requirements

    NASA Technical Reports Server (NTRS)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  19. Cyclotron harmonic lines in magnetic fluctuations of spiralling electrons in plasmas

    NASA Technical Reports Server (NTRS)

    Golubiatnikov, G.; Stenzel, R. L.

    1993-01-01

    The magnetic fluctuation spectrum in a magnetoplasma containing energetic electrons is observed to exhibit many lines at the cyclotron harmonics. It is shown that these fluctuations are neither due to cyclotron radiation nor due to velocity-space instabilities but due to coherent solenoidal fields produced by electron cyclotron orbits and excited by thermal fluctuations. Such line spectra, observed in discharges and beam-plasma systems, may be useful for precise magnetic field diagnostics in plasmas.

  20. Power line field sensing to support autonomous navigation of small unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    Matthews, John; Bukshpun, Leonid; Pradhan, Ranjit

    2013-06-01

    Autonomous navigation around power lines in a complex urban environment is a critical challenge facing small unmanned aerial vehicles (SUAVs). As part of an ongoing development of an electric and magnetic field sensor system designed to provide SUAVs with the capability to sense and avoid power transmission and distribution lines by monitoring their electric and magnetic field signatures, we have performed field measurements and analysis of power-line signals. We discuss the nature of the power line signatures to be detected, and optimal strategies for detecting these signals amid SUAV platform noise and environmental interference. Based on an analysis of measured power line signals and vehicle noise, we have found that, under certain circumstances, power line harmonics can be detected at greater range than the fundamental. We explain this phenomenon by combining a model of power line signal nonlinearity with the quasi-static electric and magnetic signatures of multiphase power lines.

  1. A Novel Multimode Waveguide Coupler for Accurate Power Measurement of Traveling Wave Tube Harmonic Frequencies

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.; Simons, Rainee N.

    2014-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from two dissimilar waveguides is capable of isolating the power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT). In addition to accurate power measurements at harmonic frequencies, a potential application of the MDC is in the design of a beacon source for atmospheric propagation studies at millimeter-wave frequencies.

  2. A Portable Low-Power Harmonic Radar System and Conformal Tag for Insect Tracking

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Harmonic radar systems provide an effective modality for tracking insect behavior. This paper presents a harmonic radar system proposed to track the migration of the Emerald Ash Borer (EAB). The system offers a unique combination of portability, low power and small tag design. It is comprised of a...

  3. Detection of harmonics and recovery of the absorption line profile using logarithmic-transformed wavelength modulation spectroscopy

    NASA Astrophysics Data System (ADS)

    Cong, Menglong; Sun, Dandan

    2016-07-01

    A versatile signal processing strategy for eliminating the residual amplitude modulation (RAM) and distortion in tunable diode laser wavelength modulation spectroscopy is theoretically demonstrated and experimentally validated. The strategy involves logarithmic transformation and differential detection, which are achieved using a homemade circuit. Through the logarithmic transformation, the optical intensity modulation of the laser, which performs as the source of RAM and distortion, is separated from the absorption-induced power attenuation and further balanced during the differential detection. The first harmonic, which is proportional to the first-order derivative of the absorption line profile in the case of a small modulation index, is extracted along with the second harmonic and is integrated for the recovery of the absorption line profile. The experiments are carried out for CH4 at its R(3) absorption line of the 2ν3 overtone for validation of the system, and the derived results are found to be in good agreement with the theoretical simulations. These promising results indicate the high potential of the strategy for absorption spectrum-based determination of gas properties.

  4. New hybrid active power filter for harmonic current suppression and reactive power compensation

    NASA Astrophysics Data System (ADS)

    Biricik, Samet; Cemal Ozerdem, Ozgur; Redif, Soydan; Sezai Dincer, Mustafa

    2016-08-01

    In the case of undistorted and balanced grid voltages, low ratio shunt active power filters (APFs) can give unity power factors and achieve current harmonic cancellation. However, this is not possible when source voltages are distorted and unbalanced. In this study, the cost-effective hybrid active power filter (HAPF) topology for satisfying the requirements of harmonic current suppression and non-active power compensation for industry is presented. An effective strategy is developed to observe the effect of the placement of power capacitors and LC filters with the shunt APF. A new method for alleviating the negative effects of a nonideal grid voltage is proposed that uses a self-tuning filter algorithm with instantaneous reactive power theory. The real-time control of the studied system was achieved with a field-programmable gate array (FPGA) architecture, which was developed using the OPAL-RT system. The performance result of the proposed HAPF system is tested and presented under nonideal supply voltage conditions.

  5. Ames Lab 101: Next Generation Power Lines

    ScienceCinema

    Russell, Alan

    2012-08-29

    Ames Laboratory scientist Alan Russell discusses the need to develop new power lines that are stronger and more conductive as a way to address the problem of the nation's aging and inadequate power grid.

  6. Harmonic distortion and power factor assessment in city street gas discharge lamps

    SciTech Connect

    Rios, S.; Castaneda, R.; Veas, D.

    1996-04-01

    The current and voltage harmonic spectrum, and power factor in gas discharge lamps: Sodium (Na)-high pressure and Mercury (Hg) in actual use in public street lighting have been measured. A sample of nearby 360 gas discharge lamps (Na, Hg) of different rated power was obtained by simple random sampling over a universe of approximately 15,000 lamps. An equivalent current harmonic spectrum for gas discharge lamps is proposed, which is independent of the type of gas and the lamp rated power. This current spectrum can be used to integrate gas discharge lamp models for harmonic distortion level assessment in distribution networks. The relation of this equivalent current harmonic spectrum with: (1) lamp voltage waveform, (2) type of lamp (Na, Hg), and (3) power factor-capacitor lamp, is analyzed.

  7. Correlation of the earth's rotation rate and the secular change of the geomagnetic field. [power spectra/harmonic analysis

    NASA Technical Reports Server (NTRS)

    Jin, R. S.

    1975-01-01

    Power spectral density analysis using Burg's maximum entropy method was applied to the geomagnetic dipole field and its rate of change for the years 1901 to 1969. Both spectra indicate relative maxima at 0.015 cycles/year and its harmonics. These maxima correspond approximately to 66, 33, 22, 17, 13, 11, and 9-year spectral lines. The application of the same analysis techniques to the length-of-day (l.o.d) fluctuations for the period 1865 to 1961 reveal similar spectral characteristics. Although peaks were observed at higher harmonics of the fundamental frequency, the 22-year and 11-year lines are not attributed unambiguously to the solar magnetic cycle and the solar cycle. It is suggested that the similarity in the l.o.d fluctuations and the dipole field variations is related to the motion within the earth's fluid core during the past one hundred years.

  8. Fast wave power flow along SOL field lines in NSTX

    NASA Astrophysics Data System (ADS)

    Perkins, R. J.; Bell, R. E.; Diallo, A.; Gerhardt, S.; Hosea, J. C.; Jaworski, M. A.; Leblanc, B. P.; Kramer, G. J.; Phillips, C. K.; Roquemore, L.; Taylor, G.; Wilson, J. R.; Ahn, J.-W.; Gray, T. K.; Green, D. L.; McLean, A.; Maingi, R.; Ryan, P. M.; Jaeger, E. F.; Sabbagh, S.

    2012-10-01

    On NSTX, a major loss of high-harmonic fast wave (HHFW) power can occur along open field lines passing in front of the antenna over the width of the scrape-off layer (SOL). Up to 60% of the RF power can be lost and at least partially deposited in bright spirals on the divertor floor and ceiling [1,2]. The flow of HHFW power from the antenna region to the divertor is mostly aligned along the SOL magnetic field [3], which explains the pattern of heat deposition as measured with infrared (IR) cameras. By tracing field lines from the divertor back to the midplane, the IR data can be used to estimate the profile of HHFW power coupled to SOL field lines. We hypothesize that surface waves are being excited in the SOL, and these results should benchmark advanced simulations of the RF power deposition in the SOL (e.g., [4]). Minimizing this loss is critical optimal high-power long-pulse ICRF heating on ITER while guarding against excessive divertor erosion.[4pt] [1] J.C. Hosea et al., AIP Conf Proceedings 1187 (2009) 105. [0pt] [2] G. Taylor et al., Phys. Plasmas 17 (2010) 056114. [0pt] [3] R.J. Perkins et al., to appear in Phys. Rev. Lett. [0pt] [4] D.L. Green et al., Phys. Rev. Lett. 107 (2011) 145001.

  9. Power Line Technician's Training. Instructional Units.

    ERIC Educational Resources Information Center

    Smith, Earle L.

    These instructional units, developed in Oklahoma, are designed for training power line technicians for rural electric cooperatives. Planned to help current employees advance in knowledge and skill, the instructional materials are divided into seven areas of training: Laborer; Groundworker or Equipment Operator; Power Line Technician, Step 1; Power…

  10. A closed-form solution to a viscoelastically supported Timoshenko beam under harmonic line load

    NASA Astrophysics Data System (ADS)

    Luo, W. L.; Xia, Y.; Zhou, X. Q.

    2016-05-01

    This study aims to formulate a closed-form solution to a viscoelastically supported Timoshenko beam under a harmonic line load. The differential governing equations of motion are converted into algebraic equations by assuming the deflection and rotation of the beam in harmonic forms with respect to time and space. The characteristic equation is biquadratic and thus contains 14 explicit roots. These roots are then substituted into Cauchy's residue theorem; consequently, five forms of the closed-form solution are generated. The present solution is consistent with that of an Euler-Bernoulli beam on a Winkler foundation, which is a special case of the present problem. The current solution is also verified through numerical examples.

  11. Generation of high-power tunable terahertz-radiation by nonrelativistic beam-echo harmonic effect

    SciTech Connect

    Gong Huarong; Xu Jin; Wei Yanyu; Gong Yubin; Travish, Gil; Feng Jinjun

    2013-01-15

    A new type of terahertz radiation source based on the nonrelativistic electron beam-wave interaction is proposed. Here, the beam echo harmonic effect is applied to a traveling wave tube like device. The scheme is configured as a combination of a frequency multiplier and amplifier with, for instance, W-band (millimeter wave) input signals and terahertz output power. A one-dimensional model of this device shows that a 10th order harmonic-wave can be generated while other harmonic waves are suppressed. The device only requires a readily available input source (W-band), and the output frequency can be tuned continuously over a wide band.

  12. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    DOEpatents

    de Rooij, Michael Andrew; Steigerwald, Robert Louis; Delgado, Eladio Clemente

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  13. Adaptive Harmonic Detection Control of Grid Interfaced Solar Photovoltaic Energy System with Power Quality Improvement

    NASA Astrophysics Data System (ADS)

    Singh, B.; Goel, S.

    2015-03-01

    This paper presents a grid interfaced solar photovoltaic (SPV) energy system with a novel adaptive harmonic detection control for power quality improvement at ac mains under balanced as well as unbalanced and distorted supply conditions. The SPV energy system is capable of compensation of linear and nonlinear loads with the objectives of load balancing, harmonics elimination, power factor correction and terminal voltage regulation. The proposed control increases the utilization of PV infrastructure and brings down its effective cost due to its other benefits. The adaptive harmonic detection control algorithm is used to detect the fundamental active power component of load currents which are subsequently used for reference source currents estimation. An instantaneous symmetrical component theory is used to obtain instantaneous positive sequence point of common coupling (PCC) voltages which are used to derive inphase and quadrature phase voltage templates. The proposed grid interfaced PV energy system is modelled and simulated in MATLAB Simulink and its performance is verified under various operating conditions.

  14. The harmonic impact of electric vehicle battery chargers on residential power distribution

    SciTech Connect

    Wang, Y.; O`Connell, R.M.; Brownfield, G.

    1999-11-01

    Electric vehicles (EV), which are powered by battery-driven electric motors, are becoming an ecologically attractive alternative to gasoline driven vehicles. One drawback to them is that the associated battery chargers are power electronic circuits which, because of their non-linear nature, can produce deleterious harmonic effects on the electric utility distribution system. To investigate the harmonic effects of widespread use of EV battery chargers, three different commercially available EV battery chargers are modeled using the injection current method to represent their current waveforms for simulation in a SPICE model of a particular distribution system.

  15. Automatic 3D power line reconstruction of multi-angular imaging power line inspection system

    NASA Astrophysics Data System (ADS)

    Zhang, Wuming; Yan, Guangjian; Wang, Ning; Li, Qiaozhi; Zhao, Wei

    2007-06-01

    We develop a multi-angular imaging power line inspection system. Its main objective is to monitor the relative distance between high voltage power line and around objects, and alert if the warning threshold is exceeded. Our multi-angular imaging power line inspection system generates DSM of the power line passage, which comprises ground surface and ground objects, for example trees and houses, etc. For the purpose of revealing the dangerous regions, where ground objects are too close to the power line, 3D power line information should be extracted at the same time. In order to improve the automation level of extraction, reduce labour costs and human errors, an automatic 3D power line reconstruction method is proposed and implemented. It can be achieved by using epipolar constraint and prior knowledge of pole tower's height. After that, the proper 3D power line information can be obtained by space intersection using found homologous projections. The flight experiment result shows that the proposed method can successfully reconstruct 3D power line, and the measurement accuracy of the relative distance satisfies the user requirement of 0.5m.

  16. Multi-line transmission in medical imaging using the second-harmonic signal.

    PubMed

    Prieur, Fabrice; Dénarié, Bastien; Austeng, Andreas; Torp, Hans

    2013-12-01

    The emergence of three-dimensional imaging in the field of medical ultrasound imaging has greatly increased the number of transmissions needed to insonify a whole volume. With a large number of transmissions comes a low image frame rate. When using classical transmission techniques, as in two-dimensional imaging, the frame rate becomes unacceptably low, prompting the use of alternative transmission patterns that require less time. One alternative is to use a multi-line transmission (MLT) technique which consists of transmitting several pulses simultaneously in different directions. Perturbations appear when acquiring and beamforming the signal in the direction of one pulse because of the pulses sent in other directions. The edge waves from the pulses transmitted in a different direction add to the signal transmitted in the direction of interest, resulting in artifacts in the final image. Taking advantage of the nonlinear propagation of sound in tissue, the second-harmonic signal can be used with the MLT technique. The image obtained using the second-harmonic signal, compared with an image obtained using the fundamental signal, should have reduced artifacts coming from other pulses transmitted simultaneously. Simulations, backed up by experiments imaging a wire target and an in vivo left ventricle, confirm that the hypothesis is valid. In the studied case, the perturbations appear as an increase in the signal level around the main echo of a point scatterer. When using the fundamental signal, the measured amplitude level of the perturbations was approximately -40 dB compared with the maximum signal amplitude (-27 dB in vivo), whereas it was around -60 dB (-45 dB in vivo) for the second-harmonic signal. The MLT technique encounters limitations in the very near field where the pulses overlap and the perturbation level also increases for images with strong speckle and low contrast. PMID:24297034

  17. Generation of high power sub-terahertz radiation from a gyrotron with second harmonic oscillation

    SciTech Connect

    Saito, Teruo; Yamada, Naoki; Ikeuti, Shinji; Tatematsu, Yoshinori; Ikeda, Ryosuke; Ogawa, Isamu; Idehara, Toshitaka; Ogasawara, Shinya; Manuilov, Vladimir N.; Shimozuma, Takashi; Kubo, Shin; Nishiura, Masaki; Tanaka, Kenji; Kawahata, Kazuo

    2012-06-15

    New power records of second harmonic gyrotron oscillation have been demonstrated in the sub-THz band. The first step gyrotron of demountable type had succeeded in oscillation with power more than 50 kW at 350 GHz and nearly 40 kW at 390 GHz [T. Notake et al., Phys. Rev. Lett. 103, 225002 (2009)]. Then, the second step gyrotron of sealed-off type was manufactured. A cavity mode was carefully selected to avoid mode competition with a neighboring fundamental harmonic mode. Matching of the selected mode with the electron gun was also circumspectly considered. The second step gyrotron has attained higher power radiation than the first gyrotron. The maximum single mode power was 62 kW at 388 GHz. Then, the electron gun was modified for use of a different cavity mode with a higher coupling coefficient than that for the 62 kW mode. The new mode proved single mode oscillation power of 83 kW at about 389 GHz. These results are new second-harmonic-oscillation power records for sub-THz gyrotrons. The present study constitutes foundations of development of high power second harmonic sub-THz gyrotron for application to collective Thomson scattering measurement on fusion plasmas, especially on high-density plasmas such as those produced in LHD [N. Ohyabu et al., Phys. Rev. Lett. 97, 055002 (2006)]. This paper reports the design consideration to realize high power single mode gyrotron oscillation at second harmonic and the examination of oscillation characteristics of the gyrotron.

  18. Bessel harmonic analysis and approximation of functions on the half-line

    NASA Astrophysics Data System (ADS)

    Platonov, Sergei S.

    2007-10-01

    We study problems of approximation of functions on \\lbrack 0, +\\infty) in the metric of L_p with power weight using generalized Bessel shifts. We prove analogues of direct Jackson theorems for the modulus of smoothness of arbitrary order defined in terms of generalized Bessel shifts. We establish the equivalence of the modulus of smoothness and the K-functional. We define function spaces of Nikol'skii-Besov type and describe them in terms of best approximations. As a tool for approximation, we use a certain class of entire functions of exponential type. In this class, we prove analogues of Bernstein's inequality and others for the Bessel differential operator and its fractional powers. The main tool we use to solve these problems is Bessel harmonic analysis.

  19. Circuit for Communication Over Power Lines

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Prokop, Normal F.; Greer, Lawrence C., III; Nappier, Jennifer

    2011-01-01

    Many distributed systems share common sensors and instruments along with a common power line supplying current to the system. A communication technique and circuit has been developed that allows for the simple inclusion of an instrument, sensor, or actuator node within any system containing a common power bus. Wherever power is available, a node can be added, which can then draw power for itself, its associated sensors, and actuators from the power bus all while communicating with other nodes on the power bus. The technique modulates a DC power bus through capacitive coupling using on-off keying (OOK), and receives and demodulates the signal from the DC power bus through the same capacitive coupling. The circuit acts as serial modem for the physical power line communication. The circuit and technique can be made of commercially available components or included in an application specific integrated circuit (ASIC) design, which allows for the circuit to be included in current designs with additional circuitry or embedded into new designs. This device and technique moves computational, sensing, and actuation abilities closer to the source, and allows for the networking of multiple similar nodes to each other and to a central processor. This technique also allows for reconfigurable systems by adding or removing nodes at any time. It can do so using nothing more than the in situ power wiring of the system.

  20. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Power line carrier systems. 15.113 Section 15... Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t), are subject only to the following requirements: (a) A power utility operating a power line carrier...

  1. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Power line carrier systems. 15.113 Section 15... Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t), are subject only to the following requirements: (a) A power utility operating a power line carrier...

  2. Concurrent Wind Cooling in Power Transmission Lines

    SciTech Connect

    Jake P Gentle

    2012-08-01

    Idaho National Laboratory and the Idaho Power Company, with collaboration from Idaho State University, have been working on a project to monitor wind and other environmental data parameters along certain electrical transmission corridors. The combination of both real-time historical weather and environmental data is being used to model, validate, and recommend possibilities for dynamic operations of the transmission lines for power and energy carrying capacity. The planned results can also be used to influence decisions about proposed design criteria for or upgrades to certain sections of the transmission lines.

  3. A high efficiency C-band internally-matched harmonic tuning GaN power amplifier

    NASA Astrophysics Data System (ADS)

    Lu, Y.; Zhao, B. C.; Zheng, J. X.; Zhang, H. S.; Zheng, X. F.; Ma, X. H.; Hao, Y.; Ma, P. J.

    2016-09-01

    In this paper, a high efficiency C-band gallium nitride (GaN) internally-matched power amplifier (PA) is presented. This amplifier consists of 2-chips of self-developed GaN high-electron mobility transistors (HEMTs) with 16 mm total gate width on SiC substrate. New harmonic manipulation circuits are induced both in the input and output matching networks for high efficiency matching at fundamental and 2nd-harmonic frequency, respectively. The developed amplifier has achieved 72.1% power added efficiency (PAE) with 107.4 W output power at 5 GHz. To the best of our knowledge, this amplifier exhibits the highest PAE in C-band GaN HEMT amplifiers with over 100 W output power. Additionally, 1000 hours' aging test reveals high reliability for practical applications.

  4. Numerical study on a 0.4 THz second harmonic gyrotron with high power

    SciTech Connect

    Chaojun, Lei; Sheng, Yu; Hongfu, Li; Yinghui, Liu; Xinjian, Niu; Qixiang, Zhao

    2013-07-15

    Terahertz and sub-terahertz science and technology are promising topics today. However, it is difficult to obtain high power source of terahertz wave. In this paper, the mode competition and beam-wave interaction in a gradually tapered cavity are studied to achieve high efficiency of a 0.4THz second harmonic gyrotron in practice. In order to attain high power and stable radiation, the TE{sub 32,5} mode is selected as the operating mode of the desired gyrotron to realize single mode oscillation. The issues of studying on the high-order mode gyrotrons are solved effectively by transforming the generalized telegraphist's equations. The efficiency and output power of the gyrotron under different conditions have been calculated by the code, which is based on the transformed equations. Consequently, the results show that single mode second harmonic radiation with power of over 150 kW at frequency of 0.4 THz could be achieved.

  5. Multimode harmonic power measurement of 40 MW pulsed S-band klystrons

    SciTech Connect

    Fowkes, W.R.; Wu, E.S.

    1984-08-01

    An array of 12 calibrated RF electric field probes on the waveguide walls are used to sample the complex field profile at the second and third harmonics where the fundamental power is in the 40 MW range at 2856 MHx. The measured amplitude and phase signals from these are Fourier analyzed to determine with good accuracy the power in each of the many possible propagating modes.

  6. Power divergences in overlapping Wilson lines

    NASA Astrophysics Data System (ADS)

    Berwein, Matthias

    2016-01-01

    We discuss the divergence structure of Wilson line operators with partially overlapping segments on the basis of the cyclic Wilson loop as an explicit example. The generalized exponentiation theorem is used to show the exponentiation and factorization of power divergences for certain linear combinations of associated loop functions.

  7. Interaction of lightning with power distribution lines

    NASA Astrophysics Data System (ADS)

    Mata, Carlos Tomas

    Triggered-lightning experiments were conducted in 1996, 1999, and 2000 to study the responses of overhead power distribution lines to lightning at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The lightning was artificially initiated (triggered) from natural thunderclouds using the rocket-and-wire technique, and its current was directed to a phase conductor at midspan or at a pole near the center of the line. Experimental results and associated EMTP modeling are presented in this dissertation for the following line configurations: (1)a two-conductor, 740-m overhead distribution line with 2 arrester stations in 1996; (2)a four- conductor, 245-m overhead distribution line with 2 arrester stations in 1999; and (3)a four-conductor, 829-m overhead distribution line with 6 arrester stations in 2000. The three-phase lines tested in 1999 and 2000 were standard designs of a major Florida power company. Lightning peak currents injected into the lines ranged from 7 to 57 kA. Voltages and currents were measured at various locations along the line. Video and photographic cameras were used to image lightning channels and detect line flashovers. The significant results of the research are (1)flashovers between conductors were observed, both accompanied and not accompanied by arrester failures, (2)an arrester failed on seven of eight direct lightning strikes to the line in 2000, (3)arcing between conductors may prevent failures of arresters connected to the struck phase, (4)the bulk of the lightning current flows from the struck phase to neutral through the arresters closest to the strike point, (5)the withstand energy of the arresters can be exceeded due to the contribution from multiple strokes and/or relatively low-level, long-lasting current components, (6)the distribution of charge transferred to ground among multiple neutral grounds, which is determined by low-frequency, low-current grounding resistances is different from the

  8. Modeling of large aperture third harmonic frequency conversion of high power Nd:glass laser systems

    SciTech Connect

    Henesian, M.A.; Wegner, P.J.; Speck, D.R.; Bibeau, C.; Ehrlich, R.B.; Laumann, C.W.; Lawson, J.K.; Weiland, T.L.

    1991-03-13

    To provide high-energy, high-power beams at short wavelengths for inertial-confinement-fusion experiments, we routinely convert the 1.053-{mu}m output of the Nova, Nd:phosphate-glass, laser system to its third-harmonic wavelength. We describe performance and conversion efficiency modeling of the 3 {times} 3 arrays potassium-dihydrogen-phosphate crystal plates used for type II/type II phase-matched harmonic conversion of Nova 0.74-m diameter beams, and an alternate type I/type II phase-matching configuration that improves the third-harmonic conversion efficiency. These arrays provide energy conversion of up to 65% and intensity conversion to 70%. 19 refs., 11 figs.

  9. A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring.

    PubMed

    Huang, Haiyu; Chen, Pai-Yen; Hung, Cheng-Hsien; Gharpurey, Ranjit; Akinwande, Deji

    2016-01-01

    Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor, and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms. PMID:26732251

  10. A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring

    NASA Astrophysics Data System (ADS)

    Huang, Haiyu; Chen, Pai-Yen; Hung, Cheng-Hsien; Gharpurey, Ranjit; Akinwande, Deji

    2016-01-01

    Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor, and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms.

  11. A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring

    PubMed Central

    Huang, Haiyu; Chen, Pai-Yen; Hung, Cheng-Hsien; Gharpurey, Ranjit; Akinwande, Deji

    2016-01-01

    Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor, and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms. PMID:26732251

  12. Power line monitoring system using fiber optic power supply

    NASA Astrophysics Data System (ADS)

    Tanaka, Yosuke; Shioda, Tatsutoshi; Kurokawa, Takashi; Oka, Junji; Ueta, Kazuyuki; Fukuoka, Toshiharu

    2009-05-01

    We propose a novel power-line-monitoring system using optical fibers for transmitting power as well as signal. The principle is experimentally confirmed with a system composed of a monitoring side with a 1.5-μm laser diode, transmission line of a single mode fiber, and a sensing side having an efficient photovoltaic (PV) cell, electrical junction sensor, and low power liquid crystal optical modulator (LCOM). The PV cell generates the electrical power in the sensing side with a conversion efficiency of 20%. The LCOM is driven with low power of less than 50 μW, modulates the laser light with a signal indicating the power line condition, and transmits the optical signal. The developed sensing unit produces an optical signal having an extinction ratio of 15 dB with low optical power of 1.8 mW. Five systems were in operation for two years, faithfully monitoring the oil pressure in electrical cables every 20 min without incident.

  13. Development of a novel high power sub-THz second harmonic gyrotron.

    PubMed

    Notake, T; Saito, T; Tatematsu, Y; Fujii, A; Ogasawara, S; Agusu, La; Ogawa, I; Idehara, T; Manuilov, V N

    2009-11-27

    Record-breaking high power coherent radiation at a subterahertz frequency region from a gyrotron utilizing second harmonic resonance modes was attained with a simple cavity. In order to aim at high power and high frequency simultaneously, the oscillation mode was selected carefully enough to realize stable radiation free from mode competition. The cavity radius was determined from the viewpoints of the oscillation frequency, the coupling coefficient between the electron beam, and the rf-electric field. The cavity length was also optimized for the highest perpendicular efficiency. In addition, a new electron gun which is capable of generating a thin laminar beam for a large current was introduced. Consequently, single mode second harmonic radiation with powers of 52 and 37 kW at frequencies of about 349 and 390 GHz, respectively, was achieved. PMID:20366101

  14. Development of a Novel High Power Sub-THz Second Harmonic Gyrotron

    SciTech Connect

    Notake, T.; Saito, T.; Tatematsu, Y.; Fujii, A.; Ogasawara, S.; Agusu, La; Ogawa, I.; Idehara, T.; Manuilov, V. N.

    2009-11-27

    Record-breaking high power coherent radiation at a subterahertz frequency region from a gyrotron utilizing second harmonic resonance modes was attained with a simple cavity. In order to aim at high power and high frequency simultaneously, the oscillation mode was selected carefully enough to realize stable radiation free from mode competition. The cavity radius was determined from the viewpoints of the oscillation frequency, the coupling coefficient between the electron beam, and the rf-electric field. The cavity length was also optimized for the highest perpendicular efficiency. In addition, a new electron gun which is capable of generating a thin laminar beam for a large current was introduced. Consequently, single mode second harmonic radiation with powers of 52 and 37 kW at frequencies of about 349 and 390 GHz, respectively, was achieved.

  15. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or near... equipment traveling under or near a power line on a construction site with no load. Equipment traveling on...

  16. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or near... equipment traveling under or near a power line on a construction site with no load. Equipment traveling on...

  17. Reliability of IGBT in a STATCOM for Harmonic Compensation and Power Factor Correction

    SciTech Connect

    Gopi Reddy, Lakshmi Reddy; Tolbert, Leon M; Ozpineci, Burak; Xu, Yan; Rizy, D Tom

    2012-01-01

    With smart grid integration, there is a need to characterize reliability of a power system by including reliability of power semiconductors in grid related applications. In this paper, the reliability of IGBTs in a STATCOM application is presented for two different applications, power factor correction and harmonic elimination. The STATCOM model is developed in EMTP, and analytical equations for average conduction losses in an IGBT and a diode are derived and compared with experimental data. A commonly used reliability model is used to predict reliability of IGBT.

  18. In-line production of a bi-circular field for generation of helically polarized high-order harmonics

    NASA Astrophysics Data System (ADS)

    Kfir, Ofer; Bordo, Eliyahu; Ilan Haham, Gil; Lahav, Oren; Fleischer, Avner; Cohen, Oren

    2016-05-01

    The recent demonstration of bright circularly polarized high-order harmonics of a bi-circular pump field gave rise to new opportunities in ultrafast chiral science. In previous works, the required nontrivial bi-circular pump field was produced using a relatively complicated and sensitive Mach-Zehnder-like interferometer. We propose a compact and stable in-line apparatus for converting a quasi-monochromatic linearly polarized ultrashort driving laser field into a bi-circular field and employ it for generation of helically polarized high-harmonics. Furthermore, utilizing the apparatus for a spectroscopic spin-mixing measurement, we identify the photon spins of the bi-circular weak component field that are annihilated during the high harmonics process.

  19. Modified Perfect Harmonics Cancellation Control of a Grid Interfaced SPV Power Generation

    NASA Astrophysics Data System (ADS)

    Singh, B.; Shahani, D. T.; Verma, A. K.

    2015-03-01

    This paper deals with a grid interfaced solar photo voltaic (SPV) power generating system with modified perfect harmonic cancellation (MPHC) control for power quality improvement in terms of mitigation of the current harmonics, power factor correction, control of point of common coupling (PCC) voltage with reactive power compensation and load balancing in a three phase distribution system. The proposed grid interfaced SPV system consists of a SPV array, a dc-dc boost converter and a voltage source converter (VSC) used for the compensation of other connected linear and nonlinear loads at PCC. The reference grid currents are estimated using MPHC method and control signals are derived by using pulse width modulation (PWM) current controller of VSC. The SPV power is fed to the common dc bus of VSC and dc-dc boost converter using maximum power point tracking (MPPT). The dc link voltage of VSC is regulated by using dc voltage proportional integral (PI) controller. The analysis of the proposed SPV power generating system is carried out under dc/ac short circuit and severe SPV-SX and SPV-TX intrusion.

  20. HHFW Power Flow Along Magnetic Field Lines In The Scrape-off Layer of NSTX

    SciTech Connect

    Rory Perkins, et. al.

    2012-02-27

    A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast wave heating and current drive.

  1. Design of broadband class-F power amplifier with high-order harmonic suppression for S-band application

    NASA Astrophysics Data System (ADS)

    Junming, Lin; Guohao, Zhang; Yaohua, Zheng; Sizhen, Li; Zhihao, Zhang; Sidi, Chen

    2015-12-01

    A broadband class-F power amplifier for an S-band handset device is integrated on a 3 × 3 × 0.82 mm3 die using an InGaP/GaAs HBT process. With LC serial harmonic traps immersed into the broadband output matching circuit, good harmonic suppression performance can be achieved. A pure resistive impedance of the matching circuit, but near zero at second and infinite at third harmonic frequency, which enhances the efficiency, is obtained across 1.8-2.5 GHz. Tested with a continuous wave (CW) signal, the PA delivers an output power of 34 dBm and achieves a PAE of 57% at 2 GHz. In addition, excellent harmonic suppression levels of less than -53 dBc across the second to fifth harmonic are obtained.

  2. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... qualified person with respect to electrical power transmission and distribution). ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or...

  3. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... qualified person with respect to electrical power transmission and distribution). ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or...

  4. Geomagnetic field-line resonant harmonics measured by the Viking and AMPTE/CCE magnetic field experiments

    NASA Technical Reports Server (NTRS)

    Zanetti, L. J.; Potemra, T. A.; Erlandson, R. E.; Engebretson, M. J.; Acuna, M. H.

    1987-01-01

    The first simultaneous observations of multiple harmonic, azimuthally polarized, ULF pulsations at two points along a geomagnetic flux tube in space are reported. In March 1986, the elliptically orbiting equatorial AMPTE/CCE satellite was oriented with the apogee near 0830 h MLT, and the orbital plane of the polar-orbiting Viking satellite was at 1000 MLT. The satellites were situated within approximately the same flux tube but with an effective separation of approximately 10 R(e) near L = 8 on the inbound pass of the AMPTE/CCE orbit. Structured harmonic pulsations were observed by the magnetic field experiments on both spacecraft, and they appeared to turn off and on simultaneously at both locations. Both the observations and the relative amplitudes along the magnetic field lines support recent ideas of multiple field-line resonances of Alfven waves.

  5. Reconstruction of crystal band structure from the power spectrum of strong-field generated high harmonics

    NASA Astrophysics Data System (ADS)

    Wang, Chang-Ming; Ho, Tak-San; Chu, Shih-I.

    2016-05-01

    The study of high harmonic generation in solid driven by intense laser fields is a subject of much current interest. Recently we introduce a new optimization method to directly reconstruct the band structure of the crystal from the power spectrum of strong-field generated high harmonics. Without loss of generality, the reconstruction is formulated for a one-dimensional single band model as a minimization problem and solved by a derivative-free unconstrained optimization algorithm-NEWUOA. The method can be readily generalized to treat multi-band problems. Numerical simulations are presented to demonstrate the applicability of the method, and the reconstructed band structure is found to be in excellent agreement with the exact one. It is also shown that our optimization method remains robust and efficient even starting from the poorly guessed band structure.

  6. U. H. F. Power Transistors and Lecher Line Oscillators.

    ERIC Educational Resources Information Center

    Howes, R. W.

    1980-01-01

    Describes the use of transistors instead of valves for Lecher line and radiation demonstrations. Two oscillator circuits which provide power for Lecher line use are described. Impedance of Lecher line is also discussed. (HM)

  7. Apparatus and Method for Communication over Power Lines

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, Lawrence C., III (Inventor); Nappier, Jennifer M. (Inventor)

    2015-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  8. Current transducers used in power line measurements

    NASA Astrophysics Data System (ADS)

    Milcarz, Sz.; Gołebiowski, J.

    2014-08-01

    There are many solutions used for current measurements in power lines. The study shows a transducer consisting of a ferromagnetic core, a beam placed in an air-gap and a sensor for optical readout. The beam is made of silicon with a thin 50%Ni50%Fe film. The material of the core is permalloy. A distribution of magnetic field depends on current supplying the power line. The beam is deflected due to magnetic field in the air-gap. A deflection of the beam is measured by the optical fibre sensor. Its advantage is simple design, high precision of processing, non-electric transmission, low costs and ability of a non-contact measurement. Comsol Multiphysics 4.4 and Magnetic Fields Module (mef) were used for modeling. An influence of magnetic circuit's materials and dimensions of the ferromagnetic core and the air-gap were tested in order to determine the most sufficient distribution of magnetic field in the air-gap. The study shows results of the modeling of the transducer compared to practical results for a similar construction scaled down to lower current values.

  9. Coupling interaction between the power coupler and the third harmonic superconducting cavity

    SciTech Connect

    Li, Jianjian; Solyak, Nikolay; Wong, Thomas; /IIT, Chicago

    2007-06-01

    Fermilab has developed a third harmonic superconducting cavity operating at the frequency of 3.9 GHz to improve the beam performance for the FLASH user facility at DESY. It is interesting to investigate the coupling interaction between the SRF cavity and the power coupler with or without beam loading. The coupling of the power coupler to the cavity needs to be determined to minimize the power consumption and guarantee the best performance for a given beam current. In this paper, we build and analyze an equivalent circuit model containing a series of lumped elements to represent the resonant system. An analytic solution of the required power from the generator as a function of the system parameters has also been given based on a vector diagram.

  10. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  11. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  12. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  13. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  14. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  15. X-Band Strip-Line Power Divider/Combiner

    NASA Technical Reports Server (NTRS)

    Conroy, B. L.

    1985-01-01

    Strip-line circuit for X-band signals both divides and combines microwave power for distributed amplifier. Strip-line pattern (foil pattern over insulating layer over ground plane) laid out so all eight distributed ports lie at electrical distances of odd integral multiples of half wavelength from main input/output port. Strip line used as power divider and as power combiner.

  16. Unequal-Split Strip-Line Power Divider

    NASA Technical Reports Server (NTRS)

    Bailey, M. C.

    1982-01-01

    Simple technique for designing strip-line or microstrip power dividers can be used for unequal, but inphase power split. Technique allows power splits ranging from equal to as large as required, with advantage of using same line impedances and line spacings for all splits. Output power ratio is determined by selecting location of input port in manner analogous to tap point for electric-power transformer.

  17. Observations of radiation from power lines in near-earth space

    NASA Astrophysics Data System (ADS)

    Korepanov, V. E.; Dudkin, F. L.; Pronenko, V. A.

    2015-09-01

    The possible effects of technogenic impacts on the ionosphere, with the continuing trend towards its sustainable growth, are unknown today. It is therefore very important and urgent task to conduct statistically valid research related to the study of variations of ionospheric parameters due to the influence of powerful technogenic factors, primarily due to a significant increase of the electromagnetic energy production. In this paper, we discuss new results of observations of electromagnetic fields in the ionosphere at the power lines main frequency of 50 (60) Hz and its harmonics onboard SICH-1M (2004) and CHIBIS-M (2012-2014) satellites. The spatial distribution of the observed phenomena and their connection with possible ground-based sources-powerful transmission lines is presented. It is concluded that organization of regular monitoring of technogenic fields may allow continuous control of energy consumption in both the local (within a country or even a powerful consumer) and global scales.

  18. Low-Power Analog Processing for Sensing Applications: Low-Frequency Harmonic Signal Classification

    PubMed Central

    White, Daniel J.; William, Peter E.; Hoffman, Michael W.; Balkir, Sina

    2013-01-01

    A low-power analog sensor front-end is described that reduces the energy required to extract environmental sensing spectral features without using Fast Fouriér Transform (FFT) or wavelet transforms. An Analog Harmonic Transform (AHT) allows selection of only the features needed by the back-end, in contrast to the FFT, where all coefficients must be calculated simultaneously. We also show that the FFT coefficients can be easily calculated from the AHT results by a simple back-substitution. The scheme is tailored for low-power, parallel analog implementation in an integrated circuit (IC). Two different applications are tested with an ideal front-end model and compared to existing studies with the same data sets. Results from the military vehicle classification and identification of machine-bearing fault applications shows that the front-end suits a wide range of harmonic signal sources. Analog-related errors are modeled to evaluate the feasibility of and to set design parameters for an IC implementation to maintain good system-level performance. Design of a preliminary transistor-level integrator circuit in a 0.13 μm complementary metal-oxide-silicon (CMOS) integrated circuit process showed the ability to use online self-calibration to reduce fabrication errors to a sufficiently low level. Estimated power dissipation is about three orders of magnitude less than similar vehicle classification systems that use commercially available FFT spectral extraction. PMID:23892765

  19. Low-power analog processing for sensing applications: low-frequency harmonic signal classification.

    PubMed

    White, Daniel J; William, Peter E; Hoffman, Michael W; Balkir, Sina

    2013-01-01

    A low-power analog sensor front-end is described that reduces the energy required to extract environmental sensing spectral features without using Fast Fouriér Transform (FFT) or wavelet transforms. An Analog Harmonic Transform (AHT) allows selection of only the features needed by the back-end, in contrast to the FFT, where all coefficients must be calculated simultaneously. We also show that the FFT coefficients can be easily calculated from the AHT results by a simple back-substitution. The scheme is tailored for low-power, parallel analog implementation in an integrated circuit (IC). Two different applications are tested with an ideal front-end model and compared to existing studies with the same data sets. Results from the military vehicle classification and identification of machine-bearing fault applications shows that the front-end suits a wide range of harmonic signal sources. Analog-related errors are modeled to evaluate the feasibility of and to set design parameters for an IC implementation to maintain good system-level performance. Design of a preliminary transistor-level integrator circuit in a 0.13 µm complementary metal-oxide-silicon (CMOS) integrated circuit process showed the ability to use online self-calibration to reduce fabrication errors to a sufficiently low level. Estimated power dissipation is about three orders of magnitude less than similar vehicle classification systems that use commercially available FFT spectral extraction. PMID:23892765

  20. Automatic Railway Power Line Extraction Using Mobile Laser Scanning Data

    NASA Astrophysics Data System (ADS)

    Zhang, Shanxin; Wang, Cheng; Yang, Zhuang; Chen, Yiping; Li, Jonathan

    2016-06-01

    Research on power line extraction technology using mobile laser point clouds has important practical significance on railway power lines patrol work. In this paper, we presents a new method for automatic extracting railway power line from MLS (Mobile Laser Scanning) data. Firstly, according to the spatial structure characteristics of power-line and trajectory, the significant data is segmented piecewise. Then, use the self-adaptive space region growing method to extract power lines parallel with rails. Finally use PCA (Principal Components Analysis) combine with information entropy theory method to judge a section of the power line whether is junction or not and which type of junction it belongs to. The least squares fitting algorithm is introduced to model the power line. An evaluation of the proposed method over a complicated railway point clouds acquired by a RIEGL VMX450 MLS system shows that the proposed method is promising.

  1. Study of second harmonic generation by high power laser beam in magneto plasma

    SciTech Connect

    Sharma, Prerana; Sharma, R. P.

    2012-12-15

    This paper examines the problem of nonlinear generation of second harmonic of a high power laser pulse propagating in magnetized plasma. The propagation of strong laser beam is proposed in the direction perpendicular to a relatively weak static magnetic field. The laser pulse is taken to be linearly polarized, with the orientation of its electric field that corresponds to an ordinary electromagnetic wave. Besides the standard ponderomotive nonlinearity, the appropriate wave equation also contains the nonlinearity that arises from the relativistic electron jitter velocities. During its propagation, the laser beam gets filamented on account of relativistic and pondermotive nonlinearities present in the plasma. The generated plasma wave gets coupled into the filamentary structures of the pump beam. Due to the expected presence of the beam filamentation, the work has been carried out by considering modified paraxial approximation (i.e., beyond the standard paraxial approximation of a very broad beam). It is found that the power of the plasma wave is significantly affected by the magnetic field strength in the presence of both relativistic and pondermotive nonlinearities. It is investigated that the second harmonic generation is also considerably modified by altering the strength of magnetic field. To see the effect of static magnetic field on the harmonic generation, a key parameter, i.e., the ratio of the cyclotron frequency {omega}{sub c}=eB{sub 0}/mc over the laser frequency {omega}{sub 0} has been used, where c is the velocity of light, m and e are the mass and charge of the electron and B{sub 0} is the externally applied magnetic field.

  2. Study of second harmonic generation by high power laser beam in magneto plasma

    NASA Astrophysics Data System (ADS)

    Sharma, Prerana; Sharma, R. P.

    2012-12-01

    This paper examines the problem of nonlinear generation of second harmonic of a high power laser pulse propagating in magnetized plasma. The propagation of strong laser beam is proposed in the direction perpendicular to a relatively weak static magnetic field. The laser pulse is taken to be linearly polarized, with the orientation of its electric field that corresponds to an ordinary electromagnetic wave. Besides the standard ponderomotive nonlinearity, the appropriate wave equation also contains the nonlinearity that arises from the relativistic electron jitter velocities. During its propagation, the laser beam gets filamented on account of relativistic and pondermotive nonlinearities present in the plasma. The generated plasma wave gets coupled into the filamentary structures of the pump beam. Due to the expected presence of the beam filamentation, the work has been carried out by considering modified paraxial approximation (i.e., beyond the standard paraxial approximation of a very broad beam). It is found that the power of the plasma wave is significantly affected by the magnetic field strength in the presence of both relativistic and pondermotive nonlinearities. It is investigated that the second harmonic generation is also considerably modified by altering the strength of magnetic field. To see the effect of static magnetic field on the harmonic generation, a key parameter, i.e., the ratio of the cyclotron frequency ωc=eB0/mc over the laser frequency ω0 has been used, where c is the velocity of light, m and e are the mass and charge of the electron and B0 is the externally applied magnetic field.

  3. High efficiency fourth-harmonic generation from nanosecond fiber master oscillator power amplifier

    NASA Astrophysics Data System (ADS)

    Mu, Xiaodong; Steinvurzel, Paul; Rose, Todd S.; Lotshaw, William T.; Beck, Steven M.; Clemmons, James H.

    2016-03-01

    We demonstrate high power, deep ultraviolet (DUV) conversion to 266 nm through frequency quadrupling of a nanosecond pulse width 1064 nm fiber master oscillator power amplifier (MOPA). The MOPA system uses an Yb-doped double-clad polarization-maintaining large mode area tapered fiber as the final gain stage to generate 0.5-mJ, 10 W, 1.7- ns single mode pulses at a repetition rate of 20 kHz with measured spectral bandwidth of 10.6 GHz (40 pm), and beam qualities of Mx 2=1.07 and My 2=1.03, respectively. Using LBO and BBO crystals for the second-harmonic generation (SHG) and fourth-harmonic generation (FHG), we have achieved 375 μJ (7.5 W) and 92.5 μJ (1.85 W) at wavelengths of 532 nm and 266 nm, respectively. To the best of our knowledge these are the highest narrowband infrared, green and UV pulse energies obtained to date from a fully spliced fiber amplifier. We also demonstrate high efficiency SHG and FHG with walk-off compensated (WOC) crystal pairs and tightly focused pump beam. An SHG efficiency of 75%, FHG efficiency of 47%, and an overall efficiency of 35% from 1064 nm to 266 nm are obtained.

  4. Compact second-harmonic generation laser module with 1 W optical output power at 490 nm.

    PubMed

    Fiebig, Christian; Sahm, Alexander; Uebernickel, Mirko; Blume, Gunnar; Eppich, Bernd; Paschke, Katrin; Erbert, Götz

    2009-12-01

    We demonstrate continues-wave 1 W at 490 nm on a 2.5 cm(3) micro-optical bench using single-path second-harmonic generation with a periodically poled MgO:LiNbO(3) bulk crystal. The pump laser is a distributed Bragg reflector tapered diode laser having a single-frequency spectrum and a pump power of 9.5 W. Based on that 1 W blue light could be achieved resulting in an optical conversion efficiency of 11%. Furthermore, the module has an output power stability of better than 2% and the blue laser beam shows an nearly diffraction limited beam quality of M(2)(sigma) = 1.2 in vertical and M(2)(sigma) = 2 in lateral direction. PMID:20052204

  5. High-power operation of a [ital K]-band second-harmonic gyroklystron

    SciTech Connect

    Lawson, W.; Matthews, H.W.; Lee, M.K.E.; Calame, J.P.; Hogan, B.; Cheng, J.; Latham, P.E.; Granatstein, V.L.; Reiser, M. )

    1993-07-19

    Amplification studies of a two-cavity second-harmonic gyroklystron are reported. A magnetron injection gun produces a 440 kV, 200--245 A, 1 [mu]s beam with an average perpendicular-to-parallel velocity ratio slightly less than 1. The TE[sub 011] input cavity is driven near 9.88 GHz and the TE[sub 021] output cavity resonates near 19.76 GHz. Peak powers exceeding 21 MW are achieved with an efficiency near 21% and a large signal gain above 25 dB. This performance represents the current state of the art for gyroklystrons in terms of the peak power normalized to the output wavelength squared.

  6. Cryogenic Yb:YAG picosecond laser with high average power visible and ultraviolet harmonic generation

    NASA Astrophysics Data System (ADS)

    Brown, D. C.; Kowalewski, K.; Envid, V.; Zembek, J.; Canale, B.; Kolis, J. W.; McMillen, C. D.; Geisber, H.

    2012-06-01

    Cryogenic Yb:YAG lasers operating at 1029 nm have been demonstrated at Snake Creek Lasers with high average power CW and ultrafast output powers, and provide near diffraction-limited output beams that are ideal for applications in harmonic generation. We describe experiments that have produced high average power green output power at 515 nm as well as preliminary experiments producing UV output power at 257.25 nm. Frequency doubling experiments used a 20 mm long non-critically phase-matched LBO crystal mounted in a constant temperature oven. A mode-locked Yb fiber laser operating at 50 MHz was used to drive a two Yb:YAG cryogenic amplifier system, producing hundreds of watts of average power output with a FWHM pulsewidth of 12 ps. Doubling efficiencies of > 50 % have been observed. For frequency quadrupling, we have used hydrothermally grown KTTP crystals grown at Clemson University and Advanced Photonic Crystals. KBBF offers unprecedented UV transmission down to 155 nm, and was used in a Type I phasematching configuration. The properties of KBBF will be discussed, as well as the experimental results observed and conversion efficiency.

  7. Research of on-line monitoring method for insulation condition of power transformer bushing

    NASA Astrophysics Data System (ADS)

    Xia, Jiuyun; Qian, Zheng; Yu, Hao; Yao, Junda

    2016-01-01

    The power transformer is the key equipment of the power system; its insulation condition will directly influence the security and reliability of the power system. Thus, the on-line monitoring of power transformer is urgently required in order to guarantee the normal operation of the power system. Moreover, the dielectric loss factor is a significant parameter reflecting the condition of transformer bushing, so the on-line measurement of dielectric loss factor is really important. In this paper, the phase-to-phase comparison method is selected as the on-line monitoring method based on the overall analysis and discussion of the existing on-line monitoring methods. At first, the harmonic analysis method is utilized to calculate the dielectric loss of each phase of the three-phase transformer bushing, and then the differences of dielectric loss between every two phases are calculated and analyzed. So the insulation condition of each bushing could be achieved based on the careful analysis of different phase-to-phase dielectric loss. The simulation results of phase-to-phase comparison method are carried out in this paper, and the validity is verified. At last, this method is utilized in an actual equipment of on-line monitoring.

  8. Resolution-Enhanced Harmonic and Interharmonic Measurement for Power Quality Analysis in Cyber-Physical Energy System

    PubMed Central

    Liu, Yanchi; Wang, Xue; Liu, Youda; Cui, Sujin

    2016-01-01

    Power quality analysis issues, especially the measurement of harmonic and interharmonic in cyber-physical energy systems, are addressed in this paper. As new situations are introduced to the power system, the impact of electric vehicles, distributed generation and renewable energy has introduced extra demands to distributed sensors, waveform-level information and power quality data analytics. Harmonics and interharmonics, as the most significant disturbances, require carefully designed detection methods for an accurate measurement of electric loads whose information is crucial to subsequent analyzing and control. This paper gives a detailed description of the power quality analysis framework in networked environment and presents a fast and resolution-enhanced method for harmonic and interharmonic measurement. The proposed method first extracts harmonic and interharmonic components efficiently using the single-channel version of Robust Independent Component Analysis (RobustICA), then estimates the high-resolution frequency from three discrete Fourier transform (DFT) samples with little additional computation, and finally computes the amplitudes and phases with the adaptive linear neuron network. The experiments show that the proposed method is time-efficient and leads to a better accuracy of the simulated and experimental signals in the presence of noise and fundamental frequency deviation, thus providing a deeper insight into the (inter)harmonic sources or even the whole system. PMID:27355946

  9. Resolution-Enhanced Harmonic and Interharmonic Measurement for Power Quality Analysis in Cyber-Physical Energy System.

    PubMed

    Liu, Yanchi; Wang, Xue; Liu, Youda; Cui, Sujin

    2016-01-01

    Power quality analysis issues, especially the measurement of harmonic and interharmonic in cyber-physical energy systems, are addressed in this paper. As new situations are introduced to the power system, the impact of electric vehicles, distributed generation and renewable energy has introduced extra demands to distributed sensors, waveform-level information and power quality data analytics. Harmonics and interharmonics, as the most significant disturbances, require carefully designed detection methods for an accurate measurement of electric loads whose information is crucial to subsequent analyzing and control. This paper gives a detailed description of the power quality analysis framework in networked environment and presents a fast and resolution-enhanced method for harmonic and interharmonic measurement. The proposed method first extracts harmonic and interharmonic components efficiently using the single-channel version of Robust Independent Component Analysis (RobustICA), then estimates the high-resolution frequency from three discrete Fourier transform (DFT) samples with little additional computation, and finally computes the amplitudes and phases with the adaptive linear neuron network. The experiments show that the proposed method is time-efficient and leads to a better accuracy of the simulated and experimental signals in the presence of noise and fundamental frequency deviation, thus providing a deeper insight into the (inter)harmonic sources or even the whole system. PMID:27355946

  10. Life Cycle Greenhouse Gas Emissions of Utility-Scale Wind Power: Systematic Review and Harmonization

    SciTech Connect

    Dolan, S. L.; Heath, G. A.

    2012-04-01

    A systematic review and harmonization of life cycle assessment (LCA) literature of utility-scale wind power systems was performed to determine the causes of and, where possible, reduce variability in estimates of life cycle greenhouse gas (GHG) emissions. Screening of approximately 240 LCAs of onshore and offshore systems yielded 72 references meeting minimum thresholds for quality, transparency, and relevance. Of those, 49 references provided 126 estimates of life cycle GHG emissions. Published estimates ranged from 1.7 to 81 grams CO{sub 2}-equivalent per kilowatt-hour (g CO{sub 2}-eq/kWh), with median and interquartile range (IQR) both at 12 g CO{sub 2}-eq/kWh. After adjusting the published estimates to use consistent gross system boundaries and values for several important system parameters, the total range was reduced by 47% to 3.0 to 45 g CO{sub 2}-eq/kWh and the IQR was reduced by 14% to 10 g CO{sub 2}-eq/kWh, while the median remained relatively constant (11 g CO{sub 2}-eq/kWh). Harmonization of capacity factor resulted in the largest reduction in variability in life cycle GHG emission estimates. This study concludes that the large number of previously published life cycle GHG emission estimates of wind power systems and their tight distribution suggest that new process-based LCAs of similar wind turbine technologies are unlikely to differ greatly. However, additional consequential LCAs would enhance the understanding of true life cycle GHG emissions of wind power (e.g., changes to other generators operations when wind electricity is added to the grid), although even those are unlikely to fundamentally change the comparison of wind to other electricity generation sources.

  11. Detection of Power Grid Harmonic Pollution Sources based on Upgraded Power Meters

    NASA Astrophysics Data System (ADS)

    Petković, Predrag; Stevanović, Dejan

    2014-05-01

    The paper suggests a new and efficient method for location of nonlinear loads on a grid. It is based on measuring of distortion power. The paper reviews different definitions of distortion power and proves that the method is feasible independently on particular definition. The obtained results of simulation and measurement confirm the effectiveness and applicability of the method. The proposed solution is suitable for software update of existing electronic power-meters or can be implement as hardware upgrade.

  12. High average power harmonic mode-locking of a Raman fiber laser based on nonlinear polarization evolution

    NASA Astrophysics Data System (ADS)

    Liu, J.; Zhao, C. J.; Gao, Y. X.; Fan, D. Y.

    2016-03-01

    We experimentally demonstrate the operation of a stable harmonically mode-locked Raman fiber laser based on the nonlinear polarization rotation technique. A maximum average output power of up to 235 mW is achieved at the repetition rate of 466.2 MHz, corresponding to the 1665th order harmonic mode-locking. The temporal width of the mode-locked pulse train is 450 ps. The experimental results should shed some light on the design of wavelength versatile ultrashort lasers with high repetition rate and average output power.

  13. 1. TEMPORARY POWER HOUSE AT ROOSEVELT DAM. TRAMWAY LINES CAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TEMPORARY POWER HOUSE AT ROOSEVELT DAM. TRAMWAY LINES CAN BE SEEN AT TOP OF PHOTOGRAPH Photographer: Walter J. Lubken, May 10, 1906 - Roosevelt Power Canal & Diversion Dam, Parallels Salt River, Roosevelt, Gila County, AZ

  14. 53. LAYOUT OF POWER CANAL LINE, LIST OF STRUCTURES Courtesy ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    53. LAYOUT OF POWER CANAL LINE, LIST OF STRUCTURES Courtesy of Reclamation Service, Salt River Project, Arizona - Roosevelt Power Canal & Diversion Dam, Parallels Salt River, Roosevelt, Gila County, AZ

  15. 2. LOOKING DOWN THE LINED POWER CANAL AS IT WINDS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. LOOKING DOWN THE LINED POWER CANAL AS IT WINDS ITS WAY TOWARD THE CEMENT MILL Photographer: Walter J. Lubken, November 19, 1907 - Roosevelt Power Canal & Diversion Dam, Parallels Salt River, Roosevelt, Gila County, AZ

  16. Coupling an induction motor type generator to ac power lines. [making windmill generators compatible with public power lines

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1984-01-01

    A system for coupling an induction motor type generator to an A.C. power line includes an electronic switch means that is controlled by a control system and is regulated to turn on at a relatively late point in each half cycle of its operation. The energizing power supplied by the line to the induction motor type generator is decreased and the net power delivered to the line is increased.

  17. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  18. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  19. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  20. Definitions of non-stationary vibration power for time-frequency analysis and computational algorithms based upon harmonic wavelet transform

    NASA Astrophysics Data System (ADS)

    Heo, YongHwa; Kim, Kwang-joon

    2015-02-01

    While the vibration power for a set of harmonic force and velocity signals is well defined and known, it is not as popular yet for a set of stationary random force and velocity processes, although it can be found in some literatures. In this paper, the definition of the vibration power for a set of non-stationary random force and velocity signals will be derived for the purpose of a time-frequency analysis based on the definitions of the vibration power for the harmonic and stationary random signals. The non-stationary vibration power, defined as the short-time average of the product of the force and velocity over a given frequency range of interest, can be calculated by three methods: the Wigner-Ville distribution, the short-time Fourier transform, and the harmonic wavelet transform. The latter method is selected in this paper because band-pass filtering can be done without phase distortions, and the frequency ranges can be chosen very flexibly for the time-frequency analysis. Three algorithms for the time-frequency analysis of the non-stationary vibration power using the harmonic wavelet transform are discussed. The first is an algorithm for computation according to the full definition, while the others are approximate. Noting that the force and velocity decomposed into frequency ranges of interest by the harmonic wavelet transform are constructed with coefficients and basis functions, for the second algorithm, it is suggested to prepare a table of time integrals of the product of the basis functions in advance, which are independent of the signals under analysis. How to prepare and utilize the integral table are presented. The third algorithm is based on an evolutionary spectrum. Applications of the algorithms to the time-frequency analysis of the vibration power transmitted from an excitation source to a receiver structure in a simple mechanical system consisting of a cantilever beam and a reaction wheel are presented for illustration.

  1. Development of a single-phase harmonic power flow program to study the 20 kHz AC power system for large spacecraft

    NASA Technical Reports Server (NTRS)

    Kraft, L. Alan; Kankam, M. David

    1991-01-01

    The development of software is described to aid in design and analysis of AC power systems for large spacecraft. The algorithm is an important version of harmonic power flow program, HARMFLO, used for the study of AC power quality. The new program is applicable to three-phase systems typified by terrestrial power systems, and single-phase systems characteristic of space power systems. The modified HARMFLO accommodates system operating frequencies ranging from terrestrial 60 Hz to and beyond aerospace 20 kHz, and can handle both source and load-end harmonic distortions. Comparison of simulation and test results of a representative spacecraft power system shows a satisfactory correlation. Recommendations are made for the direction of future improvements to the software, to enhance its usefulness to power system designer and analysts.

  2. A fast, robust algorithm for power line interference cancellation in neural recording

    NASA Astrophysics Data System (ADS)

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Objective. Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. Approach. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. Main results. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. Significance. The proposed

  3. Fiber methane gas detector based on harmonic detection and application in ventilation air methane power generation

    NASA Astrophysics Data System (ADS)

    Li, Yanfang; Wei, Yubin; Shang, Ying; Zhao, Yanjie; Zhang, Tingting; Zhao, Weisong; Wang, Chang; Liu, Tongyu

    2010-10-01

    A fiber methane detector based on spectrum absorption is reported. The methane monitor use a distributed feedback diode lasers(DFB) which is near infrared spectroscopy as the optic source, we realized online harmonic detection of the methane. The advantages of this detector include high precision, elimination of interference from humidity and other gases as well as long recalibration cycle. The detection of CH4 is very important in the methane power generation. Especially the detection of the tail gas with high temperature is the dependence to judge the generator. In this paper, we give some data witch gained from the local of methane power generation. The data reach an agreement with the measurements of the sensor using in mine. And the detector has the function of self reference, so the detector is more depended. This proved that the fiber methane detector can meet the needs of the generator. It have some contribution to the production safety of the mine and the energy saving and emission reduction and the environmental protection.

  4. Determining fine-structure parameters for tungsten powder and filings by harmonic analysis of x-ray diffraction lines

    SciTech Connect

    Kravchik, A.E.; Moshkina, T.I.; Osmakov, A.S.

    1986-12-01

    Evidence has been accumulating on determining fine-structure parameters by line shape harmonic analysis (LSHA) although many aspects remain unresolved. In this paper, the authors discuss the interpretations afresh, on-going improvements in x-ray techniques, in recording methods, and in processing the data, as well as in programs for determining the parameters by LSHA. The authors selected tungsten because of its bcc lattice, whose diffraction peaks are widely separated, which almost completely rules out their overlapping even if there is considerable broadening, such as is produced by large plastic strain. The material was produced in two ways: by firing a tungsten single crystal and by grinding VChDK tungsten powder in a laboratory vibration mill for 10, 20, 30, 50, and 100 h.

  5. The system of power on line

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Zhou, Zhen; Yang, Xu; Chen, Qiu Fu

    2004-04-01

    As the digital network is expanding so quickly, many applications are widely used in the social living, especially wireless LAN and IP telephone. The DTE(Data Terminal Equipment) based on Ethernet are also used in many place, these equipments have low power cost, but commonly they have very high requirements in stability and reliability of power supply. This article brings forward a system solution project of long-distance centralize power supply, which can be controlled by network, according to the 802.3af standard. And also presents the key technology in this solution.

  6. Power Line Integrity Monitor and Repeater

    Energy Science and Technology Software Center (ESTSC)

    2005-09-30

    The Idaho National Laboratory (INL) has developed a power system integrity monitor and repeater that provide real time status of the integrity of the physical structure of power poles and transmission towers. It may be applied to other structures, such as pipelines or cell towers, which have multiple segments that can cover hundreds of miles. Sensors and on-board processing provide indication of tampering or impending damage to the structure with information provided to the centralmore » operations center or supervisory control and data acquisition (SCADA) for mitigative actions. This software runs on a series of small, inexpensive, low power electronic sensor platforms that are mounted on each tower of an electric power transmission or distribution system for the purpose of communicating system integrity to a central location. The software allows each platform to: 1) interface with sensors that monitor tower integrity, 2) record and analyze events, 3) communicate sensor information to other sensor platforms located on adjacent towers or to a central monitoring location, and 4) derive, conserve, and store platform power from the transmission of electric power.« less

  7. Power Line Integrity Monitor and Repeater

    SciTech Connect

    Svoboda, John

    2005-09-30

    The Idaho National Laboratory (INL) has developed a power system integrity monitor and repeater that provide real time status of the integrity of the physical structure of power poles and transmission towers. It may be applied to other structures, such as pipelines or cell towers, which have multiple segments that can cover hundreds of miles. Sensors and on-board processing provide indication of tampering or impending damage to the structure with information provided to the central operations center or supervisory control and data acquisition (SCADA) for mitigative actions. This software runs on a series of small, inexpensive, low power electronic sensor platforms that are mounted on each tower of an electric power transmission or distribution system for the purpose of communicating system integrity to a central location. The software allows each platform to: 1) interface with sensors that monitor tower integrity, 2) record and analyze events, 3) communicate sensor information to other sensor platforms located on adjacent towers or to a central monitoring location, and 4) derive, conserve, and store platform power from the transmission of electric power.

  8. Extraction of power lines from mobile laser scanning data

    NASA Astrophysics Data System (ADS)

    Xiang, Qing; Li, Jonathan; Wen, Chenglu; Huang, Pengdi

    2016-03-01

    Modern urban life is becoming increasingly more dependent on reliable electric power supply. Since power outages cause substantial financial losses to producers, distributors and consumers of electric power, it is in the common interest to minimize failures of power lines. In order to detect defects as early as possible and to plan efficiently the maintenance activities, distribution networks are regularly inspected. Carrying out foot patrols or climbing the structures to visually inspect transmission lines and aerial surveys (e.g., digital imaging or most recent airborne laser scanning (ALS) are the two most commonly used methods of power line inspection. Although much faster in comparison to the foot patrol inspection, aerial inspection is more expensive and usually less accurate, in complex urban areas particularly. This paper presents a scientific work that is done in the use of mobile laser scanning (MLS) point clouds for automated extraction of power lines. In the proposed method, 2D power lines are extracted using Hough transform in the projected XOY plane and the 3D power line points are visualized after the point searching. Filtering based on an elevation threshold is applied, which is combined with the vehicle's trajectory in the horizontal section.

  9. Life Cycle Greenhouse Gas Emissions of Trough and Tower Concentrating Solar Power Electricity Generation: Systematic Review and Harmonization

    SciTech Connect

    Burkhardt, J. J.; Heath, G.; Cohen, E.

    2012-04-01

    In reviewing life cycle assessment (LCA) literature of utility-scale concentrating solar power (CSP) systems, this analysis focuses on reducing variability and clarifying the central tendency of published estimates of life cycle greenhouse gas (GHG) emissions through a meta-analytical process called harmonization. From 125 references reviewed, 10 produced 36 independent GHG emissions estimates passing screens for quality and relevance: 19 for parabolic trough (trough) technology and 17 for power tower (tower) technology. The interquartile range (IQR) of published estimates for troughs and towers were 83 and 20 grams of carbon dioxide equivalent per kilowatt-hour (g CO2-eq/kWh),1 respectively; median estimates were 26 and 38 g CO2-eq/kWh for trough and tower, respectively. Two levels of harmonization were applied. Light harmonization reduced variability in published estimates by using consistent values for key parameters pertaining to plant design and performance. The IQR and median were reduced by 87% and 17%, respectively, for troughs. For towers, the IQR and median decreased by 33% and 38%, respectively. Next, five trough LCAs reporting detailed life cycle inventories were identified. The variability and central tendency of their estimates are reduced by 91% and 81%, respectively, after light harmonization. By harmonizing these five estimates to consistent values for global warming intensities of materials and expanding system boundaries to consistently include electricity and auxiliary natural gas combustion, variability is reduced by an additional 32% while central tendency increases by 8%. These harmonized values provide useful starting points for policy makers in evaluating life cycle GHG emissions from CSP projects without the requirement to conduct a full LCA for each new project.

  10. Wireless power transfer and fault diagnosis of high-voltage power line via robotic bird

    NASA Astrophysics Data System (ADS)

    Liu, Chunhua; Chau, K. T.; Zhang, Zhen; Qiu, Chun; Li, Wenlong; Ching, T. W.

    2015-05-01

    This paper presents a new idea of wireless power transfer (WPT) and fault diagnosis (FD) of high-voltage power line via robotic bird. The key is to present the conceptual robotic bird with WPT coupling coil for detecting and capturing the energy from the high-voltage power line. If the power line works in normal condition, the robotic bird is able to stand on the power line and extract energy from it. If fault occurs on the power line, the corresponding magnetic field distribution will become different from that in the normal situation. By analyzing the magnetic field distribution of the power line, the WPT to the robotic bird and the FD by the robotic bird are performed and verified.

  11. High-peak-power second-harmonic generation of single-stage Yb-doped fiber amplifiers

    NASA Astrophysics Data System (ADS)

    Horiuchi, Ryusuke; Saiki, Koichi; Adachi, Koji; Tei, Kazuyoku; Yamaguchi, Shigeru

    2008-05-01

    A high-peak-power and high-repetition-rate fiber laser architecture is successfully demonstrated using a single-stage fiber amplifier. Nonlinear optical effects in a fiber amplifier degrade the monochromaticity of amplified laser pulses. In general, it is difficult for a non-monochromatic laser pulse to realize high-order harmonic generation with bulk nonlinear optical crystals. To overcome this problem, a single-stage amplifier architecture and a gain fiber with a high cladding absorption coefficient are employed. Furthermore, single-stage amplification enables the use of a multi-longitudinal mode electro-optically (EO) Q-switched micro seed laser. This architecture can generate a peak power of 100 kW at 50 kHz and an average power of 10 W. A second-harmonic conversion efficiency of 51% is obtained using this architecture and a LiB3O5 (LBO) crystal.

  12. Mitigation of 50-60 Hz power line interference in geophysical data

    NASA Astrophysics Data System (ADS)

    Cohen, M. B.; Said, R. K.; Inan, U. S.

    2010-12-01

    The analysis of ELF/VLF radio data has broad applications for ionospheric and magnetospheric phenomena, lightning activity, long-range communications, and geophysical prospecting. However, recordings of ELF/VLF data on the ground are adversely affected by the presence of electromagnetic fields from 50-60 Hz power lines, whose harmonics can extend to many kilohertz and interfere with the detection of natural and man-made signals. Removal of this interference is complicated by the time-varying fundamental frequency of power lines and strongly varying characteristics across different power grids. We discuss two methods for isolation and then subtraction of this interference, by an adaptive filtering technique and with least squares matrix analysis. Methods for estimating the time-varying frequency are also discussed. A few variants of these techniques are applied both to simulated data and then to real data. It is found that least squares isolation gives superior results, although the adaptive filter is potentially more effective for poorly behaved power line interference with rapidly changing fundamental frequencies as well as being computationally more efficient.

  13. Integrating Residential Photovoltaics With Power Lines

    NASA Technical Reports Server (NTRS)

    Borden, C. S.

    1985-01-01

    Report finds rooftop solar-cell arrays feed excess power to electric-utility grid for fee are potentially attractive large-scale application of photovoltaic technology. Presents assessment of breakeven costs of these arrays under variety of technological and economic assumptions.

  14. Characterization of the diversity in bat biosonar beampatterns with spherical harmonics power spectra.

    PubMed

    Motamedi, Mohammad; Müller, Rolf

    2014-06-01

    The biosonar beampatterns found across different bat species are highly diverse in terms of global and local shape properties such as overall beamwidth or the presence, location, and shape of multiple lobes. It may be hypothesized that some of this variability reflects evolutionary adaptation. To investigate this hypothesis, the present work has searched for patterns in the variability across a set of 283 numerical predictions of emission and reception beampatterns from 88 bat species belonging to four major families (Rhinolophidae, Hipposideridae, Phyllostomidae, Vespertilionidae). This was done using a lossy compression of the beampatterns that utilized real spherical harmonics as basis functions. The resulting vector representations showed differences between the families as well as between emission and reception. These differences existed in the means of the power spectra as well as in their distribution. The distributions were characterized in a low dimensional space found through principal component analysis. The distinctiveness of the beampatterns across the groups was corroborated by pairwise classification experiments that yielded correct classification rates between ~85 and ~98%. Beamwidth was a major factor but not the sole distinguishing feature in these classification experiments. These differences could be seen as an indication of adaptive trends at the beampattern level. PMID:24916408

  15. A Simulator of Periodically Switching Channels for Power Line Communications

    NASA Astrophysics Data System (ADS)

    Hayasaki, Taro; Umehara, Daisuke; Denno, Satoshi; Morikura, Masahiro

    An indoor power line is one of the most attractive media for in-home networks. However, there are many technical problems for achieving in-home power line communication (PLC) with high rate and high reliability. One of such problem is the degradation in the performance of the in-home PLC caused by periodically time-varying channel responses, particularly when connecting the switching power supply equipment. We present a measurement method for power line channel responses and reveal the switching of the channel responses synchronized with power-frequency voltage when connecting switching power supply equipment in sending or receiving outlets. In this paper, we term them periodically switching channel responses. The performance of PLC adapters is seriously affected by the periodically switching channel responses. Therefore, we provide a modeling of the periodically switching channel responses by using finite impulse response (FIR) filters with a shared channel memory and construct a simulator for in-home power line channels including the periodically switching channel responses in order to evaluate the various communication systems through the power line. We present the validity of the proposed simulator through the performance evaluation of OFDM/64QAM over periodically switching channels with additive white Gaussian noise. Furthermore, we evaluate the influence of the periodically switching channel responses on the communication quality of a time-invariant modulation scheme by using the proposed simulator.

  16. 29. CROSSCUT FACILITY PROPERTY AND POWER LINE LOCATION, SHOWING INDIAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. CROSSCUT FACILITY PROPERTY AND POWER LINE LOCATION, SHOWING INDIAN BEND POND LABELLED 'SETTLING BASIN,' STEAM/DIESEL PLANT AND OTHER FEATURES. 1951 - Crosscut Steam Plant, North side Salt River near Mill Avenue & Washington Street, Tempe, Maricopa County, AZ

  17. Living and Working Safely Around High-Voltage Power Lines.

    SciTech Connect

    United States. Bonneville Power Administration.

    2001-06-01

    High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

  18. Focusing time harmonic scalar fields in non-homogenous lossy media: Inverse filter vs. constrained power focusing optimization

    NASA Astrophysics Data System (ADS)

    Iero, D. A. M.; Isernia, T.; Crocco, L.

    2013-08-01

    Two strategies to focus time harmonic scalar fields in known inhomogeneous lossy media are compared. The first one is the Inverse Filter (IF) method, which faces the focusing task as the synthesis of a nominal field. The second one is the Constrained Power Focusing Optimization (CPFO) method, which tackles the problem in terms of constrained mask constrained power optimization. Numerical examples representative of focusing in noninvasive microwave hyperthermia are provided to show that CPFO is able to outperform IF, thanks to the additional degrees of freedom arising from the adopted power synthesis formulation.

  19. Some computational aspects of the hals (harmonic analysis of x-ray line shape) method

    SciTech Connect

    Moshkina, T.I.; Nakhmanson, M.S.

    1986-02-01

    This paper discusses the problem of distinguishing the analytical line from the background and approximates the background component. One of the constituent parts of the program package in the procedural-mathematical software for x-ray investigations of polycrystalline substances in application to the DRON-3, DRON-2 and ADP-1 diffractometers is the SSF system of programs, which is designed for determining the parameters of the substructure of materials. The SSF system is tailored not only to Unified Series (ES) computers, but also to the M-6000 and SM-1 minicomputers.

  20. Five Mass Power Transmission Line of a Ship Computer Modelling

    NASA Astrophysics Data System (ADS)

    Kazakoff, Alexander Borisoff; Marinov, Boycho Ivanov

    2016-03-01

    The work, presented in this paper, appears to be a natural continuation of the work presented and reported before, on the design of power transmission line of a ship, but with different multi-mass model. Some data from the previous investigations are used as a reference data, mainly from the analytical investigations, for the developed in the previ- ous study, frequency and modal analysis of a five mass model of a power transmission line of a ship. In the paper, a profound dynamic analysis of a concrete five mass dynamic model of the power transmission line of a ship is performed using Finite Element Analysis (FEA), based on the previously recommended model, investigated in the previous research and reported before. Thus, the partially validated by frequency analysis five mass model of a power transmission line of a ship is subjected to dynamic analysis. The objective of the work presented in this paper is dynamic modelling of a five mass transmission line of a ship, partial validation of the model and von Mises stress analysis calculation with the help of Finite Element Analysis (FEA) and comparison of the derived results with the analytically calculated values. The partially validated five mass power transmission line of a ship can be used for definition of many dy- namic parameters, particularly amplitude of displacement, velocity and acceleration, respectively in time and frequency domain. The frequency behaviour of the model parameters is investigated in frequency domain and it corresponds to the predicted one.

  1. In-line process instrumentation for geothermal power plants

    SciTech Connect

    Shannon, D.W.; Robertus, R.J.; Sullivan, R.G.; Kindle, C.H.; Pierce, D.D.

    1985-05-01

    The economics of geothermal power depend on satisfactory plant reliability of continuous operation. Plant problems and extended downtime due to corrosion failures, scale buildup, or injection well plugging have affected many past geothermal projects. If in-line instrumentation can be developed to alert plant operators to correctable problems, then the cost and reliability of geothermal power will be improved. PNL has completed a problem of development of in-line corrosion and chemical instrumentation for binary cycle plants, and this technology has been used to set up a monitoring program at the Heber Binary Demonstration Power Plant. The current emphasis has shifted to development of particle meters for use on injection lines and CO/sub 2/ and pH probes for use in control of calcite scaling. Plans have been outlined to develop and demonstrate flash plant instrumentation for corrosion monitoring, scaling, steam purity, and injection line particle counting. 2 refs., 17 figs., 1 tab.

  2. Atomic line emission and high-order harmonic generation in argon driven by 4-MHz sub-μJ laser pulses

    NASA Astrophysics Data System (ADS)

    Blättermann, Alexander; Chiang, Cheng-Tien; Widdra, Wolf

    2014-04-01

    We report on the coexistence of atomic line emission (ALE) and high-order harmonic generation (HHG) from argon with experimental conditions bridging the multiphoton and tunnel ionization regimes. Driven by sub-μJ femtosecond laser pulses in tight-focusing geometry, characteristic spectra of ALE from highly excited neutral argon as well as from singly ionized argon are detected in the presence of the harmonics. The results are discussed with respect to the electronic structure of argon and the phase-matching condition of the HHG process.

  3. Designs for a high power superconducting delay line

    SciTech Connect

    Chen, Y.J.; Caporaso, G.

    1997-06-26

    Potential designs for a high power superconducting delay line of approximately 10 microsecs duration are described. The transmitted signal should have low dispersion and little attenuation to recapture the original signal. Such demands cannot be met using conventional metal conductors. This paper outlines a proposal for a new transmission line design using low temperature superconducting material which meets system specifications. The 25 omega line is designed to carry pulsed signals with an approximate rise time of 8 nsec and a maximum voltage magnitude of 25 kV. Predicted electrical design and performance of the line will be presented.

  4. High-peak-power surface high-harmonic generation at extreme ultra-violet wavelengths from a tape

    SciTech Connect

    Shaw, B. H.; Tilborg, J. van; Sokollik, T.; Schroeder, C. B.; McKinney, W. R.; Artemiev, N. A.; Yashchuk, V. V.; Gullikson, E. M.; Leemans, W. P.

    2013-07-28

    Solid-based surface high-harmonic generation from a tape is experimentally studied. By operating at mildly relativistic normalized laser strengths a{sub 0}≲0.2, harmonics up to the 17th order are efficiently produced in the coherent wake emission (CWE) regime. CWE pulse properties, such as divergence, energy, conversion efficiency, and spectrum, are investigated for various tape materials and drive laser conditions. A clear correlation between surface roughness and harmonic beam divergence is found. At the measured pulse properties for the 15th harmonic (conversion efficiency ∼6.5×10{sup −7}, divergence ∼7−15 mrad), the 100-mJ-level drive laser produces several MWs of extreme ultra-violet pulses. The spooling tape configuration enables multi-Hz operation over thousands of shots, making this source attractive as a seed to the few-Hz laser-plasma-accelerator-driven free-electron laser (FEL). Models indicate that these CWE pulses with MW level powers are sufficient for seed-induced bunching and FEL gain.

  5. Signal pulses superimposed on power supply lines improve electrical control

    SciTech Connect

    1996-06-01

    To manipulate or monitor the operation of cranes and hoists, control engineers typically create control schemes that add numerous conductors, festoon systems, bulky dedicated conductor rails, radio and infrared controls. With modern power line communication equipment, power and intelligence can be combined to: add an unlimited number of control circuits without adding a single wire; have data communication without special cables; and eliminate bulky festoon systems and heavy cable track. Available from US Safety Trolley Corp., a SmartRail system superimposes data and control information on the power line to create a fully functional Local Area Network (LAN). The system network is based on the CEBus protocol EIA/IS-60 and uses a spread spectrum power line carrier technology. The heart of this system is the controller which manages all communication and control tasks. A power line coupling circuit couples the data signal from the controller to the a-c power conductors. These power conductors are often TRI-BAR/FOUR-BAR continuous conductor bar systems or existing conductor bar systems. The combination results in a secure data communications and control system for moving equipment.

  6. Revealing the second harmonic generation in a femtosecond laser-driven cluster-based plasma by analyzing shapes of Ar XVII spectral lines.

    PubMed

    Oks, Eugene; Dalimier, Elisabeth; Faenov, Anatoly; Pikuz, Tatiana; Fukuda, Yuji; Andreev, Alexander; Koga, James; Sakaki, Hironao; Kotaki, Hideyuki; Pirozhkov, Alexander; Hayashi, Yukio; Skobelev, Igor; Pikuz, Sergei; Kawachi, Tetsuya; Kando, Masaki; Kondo, Kiminori; Zhidkov, Alexei; Kodama, Ryosuke

    2015-12-14

    We present experiments dealing with a femtosecond laser-driven cluster-based plasma, where by analyzing the nonlinear phenomenon of satellites of spectral lines of Ar XVII, we revealed the nonlinear phenomenon of the generation of the second harmonic of the laser frequency. For performing this analysis we developed new results in the theory of satellites of spectral lines. From such lineshape analysis we found, in particular, that the efficiency of converting the short (40 fs) intense (3x10¹⁸ W/cm²) incident laser light into the second harmonic was 2%. This result is in the excellent agreement with the 2-Dimensional Particle-In-Cell (2D PIC) simulation that we also performed. There is also an order of magnitude agreement between the thresholds for the SHG found from the line shape analysis and from the 2D PIC simulations. PMID:26698990

  7. Life Cycle GHG Emissions from Conventional Natural Gas Power Generation: Systematic Review and Harmonization (Presentation)

    SciTech Connect

    Heath, G.; O'Donoughue, P.; Whitaker, M.

    2012-12-01

    This research provides a systematic review and harmonization of the life cycle assessment (LCA) literature of electricity generated from conventionally produced natural gas. We focus on estimates of greenhouse gases (GHGs) emitted in the life cycle of electricity generation from conventionally produced natural gas in combustion turbines (NGCT) and combined-cycle (NGCC) systems. A process we term "harmonization" was employed to align several common system performance parameters and assumptions to better allow for cross-study comparisons, with the goal of clarifying central tendency and reducing variability in estimates of life cycle GHG emissions. This presentation summarizes preliminary results.

  8. Digital lock-in techniques for adaptive power-line interference extraction.

    PubMed

    Dobrev, Dobromir; Neycheva, Tatyana; Mudrov, Nikolay

    2008-07-01

    This paper presents a simple digital approach for adaptive power-line (PL) or other periodic interference extraction. By means of two digital square (or sine) wave mixers, the real and imaginary parts of the interference are found, and the interference waveform is synthesized and finally subtracted. The described technique can be implemented in an open-loop architecture where the interference is synthesized as a complex sinusoid or in a closed-loop architecture for automatic phase and gain control. The same approach can be used for removal of the fundamental frequency of the PL interference as well as its higher harmonics. It is suitable for real-time operation with popular low-cost microcontrollers. PMID:18560061

  9. Simple Harmonic Motion in Harmonic Plane Waves.

    ERIC Educational Resources Information Center

    Benumof, Reuben

    1980-01-01

    Discusses the distribution of kinetic and potential energy in transverse and longitudinal waves and examines the transmission of power and momentum. This discussion is intended to aid in understanding the simple harmonic motion of a particle involved in the propagation of a harmonic mechanical plane wave. (HM)

  10. Harmonization of Initial Estimates of Shale Gas Life Cycle Greenhouse Gas Emissions for Electric Power Generation

    NASA Astrophysics Data System (ADS)

    Heath, G.; O'Donoughue, P.; Arent, D.; Bazilian, M.

    2014-12-01

    Recent technological advances in the recovery of unconventional natural gas, particularly shale gas, have served to dramatically increase domestic production and reserve estimates for the United States and internationally. This trend has led to lowered prices and increased scrutiny on production practices. Questions have been raised as to how greenhouse gas (GHG) emissions from the life cycle of shale gas production and use compares with that of conventionally produced natural gas or other fuel sources such as coal. Recent literature has come to different conclusions on this point, largely due to differing assumptions, comparison baselines, and system boundaries. Through a meta-analytical procedure we call harmonization, we develop robust, analytically consistent, and updated comparisons of estimates of life cycle GHG emissions for electricity produced from shale gas, conventionally produced natural gas, and coal. On a per unit electrical output basis, harmonization reveals that median estimates of GHG emissions from shale gas-generated electricity are similar to those for conventional natural gas, with both approximately half that of the central tendency of coal. Sensitivity analysis on the harmonized estimates indicates that assumptions regarding liquids unloading and estimated ultimate recovery (EUR) of wells have the greatest influence on life cycle GHG emissions, whereby shale gas life cycle GHG emissions could approach the range of best performing coal-fired generation under certain scenarios. Despite clarification of published estimates through harmonization, these initial assessments should be confirmed through methane emissions measurements at components and in the atmosphere and through better characterization of EUR and practices.

  11. Harmonic engine

    DOEpatents

    Bennett, Charles L.

    2009-10-20

    A high efficiency harmonic engine based on a resonantly reciprocating piston expander that extracts work from heat and pressurizes working fluid in a reciprocating piston compressor. The engine preferably includes harmonic oscillator valves capable of oscillating at a resonant frequency for controlling the flow of working fluid into and out of the expander, and also preferably includes a shunt line connecting an expansion chamber of the expander to a buffer chamber of the expander for minimizing pressure variations in the fluidic circuit of the engine. The engine is especially designed to operate with very high temperature input to the expander and very low temperature input to the compressor, to produce very high thermal conversion efficiency.

  12. 2. VIEW OF NORTHWEST CORNER OF MST. POWER LINES TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW OF NORTHWEST CORNER OF MST. POWER LINES TO CAMERA TOWER IN FOREGROUND; UMBILICAL MAST ON RIGHT SIDE OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. Steady-state and dynamic characteristics of a 20-kHz spacecraft power system - Control of harmonic resonance

    NASA Technical Reports Server (NTRS)

    Wasynczuk, O.; Krause, P. C.; Biess, J. J.; Kapustka, R.

    1990-01-01

    A detailed computer simulation was used to illustrate the steady-state and dynamic operating characteristics of a 20-kHz resonant spacecraft power system. The simulated system consists of a parallel-connected set of DC-inductor resonant inverters (drivers), a 440-V cable, a node transformer, a 220-V cable, and a transformer-rectifier-filter (TRF) AC-to-DC receiver load. Also included in the system are a 1-kW 0.8-pf RL load and a double-LC filter connected at the receiving end of the 20-kHz AC system. The detailed computer simulation was used to illustrate the normal steady-state operating characteristics and the dynamic system performance following, for example, TRF startup. It is shown that without any filtering the given system exhibits harmonic resonances due to an interaction between the switching of the source and/or load converters and the AC system. However, the double-LC filter at the receiving-end of the AC system and harmonic traps connected in series with each of the drivers significantly reduce the harmonic distortion of the 20-kHz bus voltage. Significant additional improvement in the waveform quality can be achieved by including a double-LC filter with each driver.

  14. Remote sensing methods for power line corridor surveys

    NASA Astrophysics Data System (ADS)

    Matikainen, Leena; Lehtomäki, Matti; Ahokas, Eero; Hyyppä, Juha; Karjalainen, Mika; Jaakkola, Anttoni; Kukko, Antero; Heinonen, Tero

    2016-09-01

    To secure uninterrupted distribution of electricity, effective monitoring and maintenance of power lines are needed. This literature review article aims to give a wide overview of the possibilities provided by modern remote sensing sensors in power line corridor surveys and to discuss the potential and limitations of different approaches. Monitoring of both power line components and vegetation around them is included. Remotely sensed data sources discussed in the review include synthetic aperture radar (SAR) images, optical satellite and aerial images, thermal images, airborne laser scanner (ALS) data, land-based mobile mapping data, and unmanned aerial vehicle (UAV) data. The review shows that most previous studies have concentrated on the mapping and analysis of network components. In particular, automated extraction of power line conductors has achieved much attention, and promising results have been reported. For example, accuracy levels above 90% have been presented for the extraction of conductors from ALS data or aerial images. However, in many studies datasets have been small and numerical quality analyses have been omitted. Mapping of vegetation near power lines has been a less common research topic than mapping of the components, but several studies have also been carried out in this field, especially using optical aerial and satellite images. Based on the review we conclude that in future research more attention should be given to an integrated use of various data sources to benefit from the various techniques in an optimal way. Knowledge in related fields, such as vegetation monitoring from ALS, SAR and optical image data should be better exploited to develop useful monitoring approaches. Special attention should be given to rapidly developing remote sensing techniques such as UAVs and laser scanning from airborne and land-based platforms. To demonstrate and verify the capabilities of automated monitoring approaches, large tests in various environments

  15. Limiting electric fields of HVDC overhead power lines.

    PubMed

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths. PMID:24573710

  16. Interstate power plants 8-inch HDPE gas feeder line

    SciTech Connect

    Not Available

    1982-07-01

    Interstate Power Co.'s newly laid 8-in. high density polyethylene gas feeder line on the banks of the Mississippi River from Savanna to Thomson, IL., has an expected minimum 100-year lifetime. Serving a rapidly growing industrial and residential area, the 9.5-mile distribution line is initially operating as a 60-psi system, although it is ultimately designed for 82-psi service obtained by using Plexco PE 3406/3408 pipe with a 0.639-in.-thick wall and weighing 7 lb/ft. The Thomson line is the first time Interstate has planted 8-in. pipe using a Vermeer T600C ladder trencher. Lower material and labor costs make the plastic line only 65% of the installed cost of a comparable steel pipeline.

  17. Restraint Method of Voltage Total Harmonic Distortion in Distribution Network by Power Conditioner Systems using Measured Data from IT Switches

    NASA Astrophysics Data System (ADS)

    Kawasaki, Shoji; Shimoda, Kazuki; Tanaka, Motohiro; Taoka, Hisao; Matsuki, Junya; Hayashi, Yasuhiro

    Recently, the amount of distributed generation (DG) such as photovoltaic system and wind power generator system installed in a distribution system has been increasing because of reduction of the effects on the environment. However, the harmonic troubles in the distribution system are apprehended in the background of the increase of connection of DGs through the inverters and the spread of power electronics equipment. In this paper, the authors propose a restraint method of voltage total harmonic distortion (THD) in a whole distribution network by active filter (AF) operation of plural power conditioner systems (PCS). Moreover, the authors propose a determination method of the optimal gain of AF operation so as to minimize the maximum value of voltage THD in the distribution network by the real-time feedback control with measured data from the information technology (IT) switches. In order to verify the validity of the proposed method, the numerical calculations are carried out by using an analytical model of distribution network interconnected DGs with PCS.

  18. High-power terahertz optical pulse generation with a dual-wavelength harmonically mode-locked Yb:YAG laser

    NASA Astrophysics Data System (ADS)

    Zhuang, W. Z.; Chang, M. T.; Su, K. W.; Huang, K. F.; Chen, Y. F.

    2013-07-01

    We report on high-power terahertz optical pulse generation with a dual-wavelength harmonically mode-locked Yb:YAG laser. A semiconductor saturable absorber mirror is developed to achieve synchronously mode-locked operation at two spectral bands centered at 1031.67 and 1049.42 nm with a pulse duration of 1.54 ps and a pulse repetition rate of 80.3 GHz. With a diamond heat spreader to improve the heat removal efficiency, the average output power can be up to 1.1 W at an absorbed pump power of 5.18 W. The autocorrelation traces reveal that the mode-locked pulse is modulated with a beat frequency of 4.92 THz and displays a modulation depth to be greater than 80%.

  19. High-power picoseconds 355 nm laser by third harmonic generation based on CsB3O5 crystal

    NASA Astrophysics Data System (ADS)

    Guo, L.; Wang, G. L.; Zhang, H. B.; Cui, D. F.; Wu, Y. C.; Lu, L.; Zhang, J. Y.; Huang, J. Y.; Xu, Z. Y.

    2007-07-01

    We report on the high average power third harmonic generation (THG) of a mode-locked picosecond laser in a CsB3O5 (CBO) crystal. The picosecond laser beam at 1064 nm is produced by a home-made 30 W master oscillator power-amplifier (MOPA) Nd:YVO4 laser system. The maximum THG output at 355 nm is up to 5.4 W. We also investigate the phase matching angle at different temperatures. During high power operation, the temperature of the CBO crystal is set at a high temperature of more than 100 °C. The THG system has shown a fine long-term stability for more than two months of operation.

  20. Harmonization of initial estimates of shale gas life cycle greenhouse gas emissions for electric power generation

    PubMed Central

    Heath, Garvin A.; O’Donoughue, Patrick; Arent, Douglas J.; Bazilian, Morgan

    2014-01-01

    Recent technological advances in the recovery of unconventional natural gas, particularly shale gas, have served to dramatically increase domestic production and reserve estimates for the United States and internationally. This trend has led to lowered prices and increased scrutiny on production practices. Questions have been raised as to how greenhouse gas (GHG) emissions from the life cycle of shale gas production and use compares with that of conventionally produced natural gas or other fuel sources such as coal. Recent literature has come to different conclusions on this point, largely due to differing assumptions, comparison baselines, and system boundaries. Through a meta-analytical procedure we call harmonization, we develop robust, analytically consistent, and updated comparisons of estimates of life cycle GHG emissions for electricity produced from shale gas, conventionally produced natural gas, and coal. On a per-unit electrical output basis, harmonization reveals that median estimates of GHG emissions from shale gas-generated electricity are similar to those for conventional natural gas, with both approximately half that of the central tendency of coal. Sensitivity analysis on the harmonized estimates indicates that assumptions regarding liquids unloading and estimated ultimate recovery (EUR) of wells have the greatest influence on life cycle GHG emissions, whereby shale gas life cycle GHG emissions could approach the range of best-performing coal-fired generation under certain scenarios. Despite clarification of published estimates through harmonization, these initial assessments should be confirmed through methane emissions measurements at components and in the atmosphere and through better characterization of EUR and practices. PMID:25049378

  1. Harmonization of initial estimates of shale gas life cycle greenhouse gas emissions for electric power generation.

    PubMed

    Heath, Garvin A; O'Donoughue, Patrick; Arent, Douglas J; Bazilian, Morgan

    2014-08-01

    Recent technological advances in the recovery of unconventional natural gas, particularly shale gas, have served to dramatically increase domestic production and reserve estimates for the United States and internationally. This trend has led to lowered prices and increased scrutiny on production practices. Questions have been raised as to how greenhouse gas (GHG) emissions from the life cycle of shale gas production and use compares with that of conventionally produced natural gas or other fuel sources such as coal. Recent literature has come to different conclusions on this point, largely due to differing assumptions, comparison baselines, and system boundaries. Through a meta-analytical procedure we call harmonization, we develop robust, analytically consistent, and updated comparisons of estimates of life cycle GHG emissions for electricity produced from shale gas, conventionally produced natural gas, and coal. On a per-unit electrical output basis, harmonization reveals that median estimates of GHG emissions from shale gas-generated electricity are similar to those for conventional natural gas, with both approximately half that of the central tendency of coal. Sensitivity analysis on the harmonized estimates indicates that assumptions regarding liquids unloading and estimated ultimate recovery (EUR) of wells have the greatest influence on life cycle GHG emissions, whereby shale gas life cycle GHG emissions could approach the range of best-performing coal-fired generation under certain scenarios. Despite clarification of published estimates through harmonization, these initial assessments should be confirmed through methane emissions measurements at components and in the atmosphere and through better characterization of EUR and practices. PMID:25049378

  2. Harmonic Distortion as an Influence Quantity on Reactive Static Electrical Energy Meters

    NASA Astrophysics Data System (ADS)

    Vasconcellos, M. T.; Luna, J. H. M.; Mateus, J. C.; Portugal, S. A.

    2015-01-01

    This article presents test results from static electrical energy meters, indicating their susceptibility to the total harmonic distortion (THD) present at the mains line. This particular characteristic impacts directly in measuring reactive energy and power factor for billing purposes.

  3. HIGH FREQUENCY POWER TRANSMISSION LINE FOR CYCLOTRONS AND THE LIKE

    DOEpatents

    Armstrong, W.J.

    1954-04-20

    High-frequency power transmission systems, particularly a stacked capacitance alternating power current transmission line wherein maximum utilization of the effective conductios skin of the line conductors is achieved while enabling a low impedance to be obtained are reported. The transmission line consists of a number of flat metal strips with interleaved dielectric strips. The metal dielectric strips are coiled spirally with the axis of the spiral extending along the length of the strips, and the alternating metal strips at the output end have outwardly extending aligned lugs which are directly strapped together and connected to the respective terminals on the load. At the input end of the transmission line, similarly, the alternate metal strips are directly strapped together and connected to an altereating current source. With the arrangement described each metal strip conducts on both sides, so that the metal strips are designed to have a thickness corresponding to twice the depth of the "skin effect" conducting lamina of each conductor at the source frequency.

  4. Analysis of a high power microwave radial line slot antenna.

    PubMed

    Peng, Shengren; Yuan, Chengwei; Shu, Ting

    2013-07-01

    A traditional radial line slot antenna (RLSA) is a high gain planar array. To improve the power handling capacity, we design a radial line slow wave structure which replaces a traditional dielectric sheet in the radial waveguide of the traditional RLSA. This high power microwave (HPM) RLSA is fed from a double-layered radial line waveguide to realize the directional radiation of the microwave. However, the track of the widen slot array on the upper waveguide could cause large reflection, which disturbs the normal antenna operation, accordingly a reflection canceling slot is added to the lower waveguide, the key technology employed in the design of the HPM RLSA and the antenna return-loss is effectively improved. This article mainly gives the design theory of this antenna, which is confirmed by the simulations and experiments. At 9.4 GHz, the calculated aperture efficiency reaches more than 40%, the reflectance is less than 0.1, the radiation efficiency is more than 99% and its measured power-handling capacity exceeds 700 MW. PMID:23902089

  5. Analysis of a high power microwave radial line slot antenna

    NASA Astrophysics Data System (ADS)

    Peng, Shengren; Yuan, Chengwei; Shu, Ting

    2013-07-01

    A traditional radial line slot antenna (RLSA) is a high gain planar array. To improve the power handling capacity, we design a radial line slow wave structure which replaces a traditional dielectric sheet in the radial waveguide of the traditional RLSA. This high power microwave (HPM) RLSA is fed from a double-layered radial line waveguide to realize the directional radiation of the microwave. However, the track of the widen slot array on the upper waveguide could cause large reflection, which disturbs the normal antenna operation, accordingly a reflection canceling slot is added to the lower waveguide, the key technology employed in the design of the HPM RLSA and the antenna return-loss is effectively improved. This article mainly gives the design theory of this antenna, which is confirmed by the simulations and experiments. At 9.4 GHz, the calculated aperture efficiency reaches more than 40%, the reflectance is less than 0.1, the radiation efficiency is more than 99% and its measured power-handling capacity exceeds 700 MW.

  6. A study of the application of power-spectral methods of generalized harmonic analysis to gust loads on airplanes

    NASA Technical Reports Server (NTRS)

    Press, Harry; Mazelsky, Bernard

    1954-01-01

    The applicability of some results from the theory of generalized harmonic analysis (or power-spectral analysis) to the analysis of gust loads on airplanes in continuous rough air is examined. The general relations for linear systems between power spectrums of a random input disturbance and an output response are used to relate the spectrum of airplane load in rough air to the spectrum of atmospheric gust velocity. The power spectrum of loads is shown to provide a measure of the load intensity in terms of the standard deviation (root mean square) of the load distribution for an airplane in flight through continuous rough air. For the case of a load output having a normal distribution, which appears from experimental evidence to apply to homogeneous rough air, the standard deviation is shown to describe the probability distribution of loads or the proportion of total time that the load has given values. Thus, for airplane in flight through homogeneous rough air, the probability distribution of loads may be determined from a power-spectral analysis. In order to illustrate the application of power-spectral analysis to gust-load analysis and to obtain an insight into the relations between loads and airplane gust-response characteristics, two selected series of calculations are presented. The results indicate that both methods of analysis yield results that are consistent to a first approximation.

  7. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources

    NASA Astrophysics Data System (ADS)

    Reale, D. V.; Parson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  8. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources.

    PubMed

    Reale, D V; Parson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW. PMID:27036802

  9. Investigation into the Effects of Microsecond Power Line Transients on Line-Connected Capacitors

    NASA Technical Reports Server (NTRS)

    Javor, K.

    2000-01-01

    An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage ratings needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations. and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

  10. Investigation Into The Effects of Microsecond Power Line Transients On Line-Connected Capacitors

    NASA Technical Reports Server (NTRS)

    Javor, Ken

    1999-01-01

    An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage rating needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

  11. High-power self-similar amplification seeded by a 1 GHz harmonically mode-locked Yb-fiber laser

    NASA Astrophysics Data System (ADS)

    Luo, Daping; Li, Wenxue; Liu, Yang; Wang, Chao; Zhu, Zhiwei; Zhang, Wenchao; Zeng, Heping

    2016-08-01

    We demonstrate 1 GHz, 75 W, 65 fs pulse generation through chirped-pulse and self-similar amplification of a second-harmonic mode-locked Yb fiber oscillator. To confirm the experimental results of a chirped-pulse pre-amplifier, a theoretically calculative model is designed to simulate gain narrowing in the amplification. Specifically, the Kelly sidebands generated by a seed laser experience similar evolution under both conditions. The grism-based self-similar amplifier together with a high-efficiency grating compressor contribute to high-power ultrashort pulses whose spectra are efficiently broadened to a maximum 10 dB bandwidth of 56 nm with a center wavelength of 1032.2 nm owing to self-phase modulation in a gain fiber.

  12. Predicting ice accretion and alleviating galloping on overhead power lines

    NASA Astrophysics Data System (ADS)

    Lu, Mingliang

    2002-04-01

    Both the static and dynamic effects of an ice storm on an overhead power line are investigated fairly comprehensively in this thesis. To determine the static, extreme ice load as well as the combined ice and wind load, a systematic procedure is established based on extensive freezing rain experiments and a Monte Carlo simulation. On the other hand, a dynamic effect---galloping---is examined quite extensively with the objective of better understanding its behavior. A novel add-on device---the hybrid nutation damper (HND)---is proposed to control galloping. Its effectiveness is assessed numerically by using a modified, 3DOF based, galloping software. The present investigations lead to the following findings. (i) Goodwin's simple theoretical model surprisingly predicts, quite accurately, the temporally changing weight of not only a dry ice growth but also a wet ice growth for a fixed, unheated conductor sample. (ii) The maximum ice loading may vary significantly over a power line's planned lifetime because of the randomness of an ice storm and its characteristics as well as the uncertainty involved in identifying the extreme probability distribution of the ice loading. Consequently, backup protection is presently essential for a power line in an ice prone area. (iii) A conductor's torsional flexibility does not appear to affect the growth of the accreted ice weight but it modifies the ice shape significantly. (iv) Three representative ice shapes (a crescent, D-like and icicle pendant) can initiate galloping so that galloping may occur in any icing condition. (v) A noticeable swingback or twist appears to develop only when their respective natural frequencies coincide with the plunge's natural frequency. (vi) A hydraulic jump is the major source of energy dissipation in a nutation damper. A properly induced rotation can significantly enhance a nutation damper's performance. (vii) A hybrid nutation damper has been demonstrated to be a promising means of alleviating

  13. Trend on High-speed Power Line Communication Technology

    NASA Astrophysics Data System (ADS)

    Ogawa, Osamu

    High-speed power line communication (PLC) is useful technology to easily build the communication networks, because construction of new infrastructure is not necessary. In Europe and America, PLC has been used for broadband networks since the beginning of 21th century. In Japan, high-speed PLC was deregulated only indoor usage in 2006. Afterward it has been widely used for home area network, LAN in hotels and school buildings and so on. And recently, PLC is greatly concerned as communication technology for smart grid network. In this paper, the author surveys the high-speed PLC technology and its current status.

  14. PCF based high power narrow line width pulsed fiber laser

    NASA Astrophysics Data System (ADS)

    Chen, H.; Yan, P.; Xiao, Q.; Wang, Y.; Gong, M.

    2012-09-01

    Based on semiconductor diode seeded multi-stage cascaded fiber amplifiers, we have obtained 88-W average power of a 1063-nm laser with high repetition rate of up to 1.5 MHz and a constant 2-ns pulse duration. No stimulated Brillouin scattering pulse or optical damage occurred although the maximum pulse peak power has exceeded 112 kW. The output laser exhibits excellent beam quality (M2x = 1.24 and M2y = 1.18), associated with a spectral line width as narrow as 0.065 nm (FWHM). Additionally, we demonstrate high polarization extinction ratio of 18.4 dB and good pulse stabilities superior to 1.6 % (RMS).

  15. The role of tissue harmonic imaging ultrasound combined with power Doppler ultrasound in the diagnosis of childhood febrile urinary tract infections

    PubMed Central

    İlarslan, Nisa Eda Çullas; Fitöz, Ömer Suat; Öztuna, Derya Gökmen; Küçük, Nuriye Özlem; Yalçınkaya, Fatma Fatoş

    2015-01-01

    Aim: This study assessed the ability of tissue harmonic imaging ultrasound combined with power Doppler ultrasound in the detection of childhood febrile urinary tract infections in comparison with the gold standard reference method: Tc-99m dimercaptosuccinicacid renal cortical scintigraphy. Material and Methods: This prospective study included 60 patients who were hospitalized with a first episode of febrile urinary tract infections. All children were examined with dimercaptosuccinicacid scan and tissue harmonic imaging ultrasound combined with power Doppler ultrasound within the first 3 days of admission. Results: Signs indicative of acute infection were observed in 29 patients according to the results of tissue harmonic imaging ultrasound combined with power Doppler ultrasound while dimercaptosuccinicacid scan revealed abnormal findings in 33 patients. The sensitivity, specificity, positive predictive value and negative predictive value of tissue harmonic imaging combined with power Doppler ultrasound using dimercaptosuccinicacid scintigraphy as the reference method in patients diagnosed with first episode febrile urinary tract infections were calculated as 57.58% (95% confidence interval: 40.81%–72.76%); 62.96% (95% confidence interval: 44.23%–78.47%); 65.52% (95% confidence interval: 52.04%–77%); 54.84% (95% confidence interval: 41.54%–67.52%); respectively. Conclusions: Although current results exhibit inadequate success of power Doppler ultrasound, this practical and radiation-free method may soon be comprise a part of the routine ultrasonographic evaluation of febrile urinary tract infections of childhood if patients are evaluated early and under appropriate sedation. PMID:26265892

  16. A Line Weighted Frequency Droop Controller for Decentralized Enforcement of Transmission Line Power Flow Constraints in Inverter-Based Networks

    SciTech Connect

    Ainsworth, Nathan G; Grijalva, Prof. Santiago

    2013-01-01

    Recent works have shown that networks of voltagesource inverters implementing frequency droop control may be analyzed as consensus-like networks. Based on this understanding, we show that enforcement of network line power flows can be viewed as an edge-preservation problem in a -disk dynamic interaction graph. Inspired by other works solving similar problems in other domains, we propose a line weighted frequency droop controller such that a network of all active buses implementing this controller enforces the specified line power flow constraints without need for communication. We provide simulation results verifying that our proposed controller limits line power to enforce constraints, and otherwise acts as a traditional droop controller.

  17. Research of on-line detection system for power capacitor

    NASA Astrophysics Data System (ADS)

    Yao, Junda; Qian, Zheng; Yu, Hao; Xia, Jiuyun

    2016-01-01

    The hidden danger exists in the power capacitor of power system due to long-time operation under the environment of high voltage. Thus, it is possible to induce serious fault, and the on-line detection system is urgently required. In this paper, two methods of the on-line detection system are compared in order to realize the better real-time condition detection. The first method is based on the STM microprocessor with an internal 12 bit A/D converter, which converts analog signals which is arrived from the sample circuit into digital signals, and then the FFT algorithm is used to accomplish the measurement of the voltage and current values of the capacitor. The second method is based on the special electric energy metering IC, which can obtain RMS (Root Mean Square) of voltage and current by processing the sampled data of the voltage and current, and store RMS of voltage and current in its certain registers. The operating condition of the capacitor can be obtained after getting the values of voltage and current. By comparing the measuring results of two methods, the second method could achieve a higher measurement accuracy and more simple construction.

  18. Fast Burst Synchronization for Power Line Communication Systems

    NASA Astrophysics Data System (ADS)

    Bumiller, Gerd; Lampe, Lutz

    2007-12-01

    Fast burst synchronization is an important requirement in asynchronous communication networks, where devices transmit short data packets in an unscheduled fashion. Such a synchronization is typically achieved by means of a preamble sent in front of the data packet. In this paper, we study fast burst synchronization for power line communication (PLC) systems operating below 500 kHz and transmitting data rates of up to about 500 kbps as it is typical in various PLC network applications. In particular, we are concerned with the receiver processing of the preamble signal and the actual design of preambles suitable for fast burst synchronization in such PLC systems. Our approach is comprehensive in that it takes into account the most distinctive characteristics of the power line channel, which are multipath propagation, highly varying path loss, and disturbance by impulse noise, as well as important practical constraints, especially the need for spectral shaping of the preamble signal and fast adjustment of the automatic gain control (AGC). In fact, we regard the explicit incorporation of these various requirements into the preamble design as the main contribution of this work. We devise an optimization criterion and a stochastic algorithm to search for suitable preamble sequences. A comprehensive performance comparison of a designed and two conventional preambles shows that the designed sequence is superior in terms of (a) fast burst synchronization in various transmission environments, (b) fast AGC adjustment, and (c) compliance of its spectrum with the spectral mask applied to the data transmit signal.

  19. Fast-wave Power Flow Along SOL Field Lines In NSTX nd The Associated Power Deposition Profile Across The SOL In Front Of The Antenna

    SciTech Connect

    Perkins, Roy

    2013-06-21

    Fast-wave heating and current drive efficiencies can be reduced by a number of processes in the vicinity of the antenna and in the scrape off layer (SOL). On NSTX from around 25% to more than 60% of the high-harmonic fast-wave power can be lost to the SOL regions, and a large part of this lost power flows along SOL magnetic field lines and is deposited in bright spirals on the divertor floor and ceiling. We show that field-line mapping matches the location of heat deposition on the lower divertor, albeit with a portion of the heat outside of the predictions. The field-line mapping can then be used to partially reconstruct the profile of lost fast-wave power at the midplane in front of the antenna, and the losses peak close to the last closed flux surface (LCFS) as well as the antenna. This profile suggests a radial standing-wave pattern formed by fast-wave propagation in the SOL, and this hypothesis will be tested on NSTX-U. Advanced RF codes must reproduce these results so that such codes can be used to understand this edge loss and to minimize RF heat deposition and erosion in the divertor region on ITER.

  20. Second harmonic generation microscopy investigation of the crystalline ultrastructure of three barley starch lines affected by hydration

    PubMed Central

    Cisek, Richard; Tokarz, Danielle; Steup, Martin; Tetlow, Ian J.; Emes, Michael J.; Hebelstrup, Kim H.; Blennow, Andreas; Barzda, Virginijus

    2015-01-01

    Second harmonic generation (SHG) microscopy is employed to study changes in crystalline organization due to altered gene expression and hydration in barley starch granules. SHG intensity and susceptibility ratio values (R’SHG) are obtained using reduced Stokes-Mueller polarimetric microscopy. The maximum R’SHG values occur at moderate moisture indicating the narrowest orientation distribution of nonlinear dipoles from the cylindrical axis of glucan helices. The maximum SHG intensity occurs at the highest moisture and amylopectin content. These results support the hypothesis that SHG is caused by ordered hydrogen and hydroxyl bond networks which increase with hydration of starch granules. PMID:26504621

  1. New live line tester for porcelain suspension insulators on high-voltage power lines

    SciTech Connect

    Vaillancourt, G.H.; St-Jean, M. ); Bellerive, J.P. ); Jean, C. )

    1994-01-01

    Suspension insulator assemblies known as insulator strings are used in overhead power transmission lines to mechanically support high-voltage conductors while providing adequate insulation to withstand switching and lightning overvoltages. Since the useful life in service of the individual insulator elements making up these strings is hard to predict, they must be verified periodically to insure that adequate line reliability is maintained at all times. Over the years many testing methods have been used for this purpose, each one with its own advantages and disadvantages. Until now at Hydro-Quebec, porcelain insulators had been tested by the buzz method which simply consists of applying a short-circuit to each insulator in a string and listening for a buzz-like sound indicating a good insulator. However, safety considerations that preclude short-circuiting insulators and other disadvantages of that method have led Hydro-Quebec to undertake and complete the development of a new insulator tester. The working principle of this new device is based on the automatic measurement and recording of the electric field along the insulator string which decreases considerably in front of an internally-shorted insulator. The tester is slid along the string while the insulators are counted automatically. The information from tests on up to 200 strings can be stored in the device to be later transferred in a host computer for interpretation and/or permanent storage. The new tester also gives information on voltage distribution along the insulator strings which can be useful for the design of future power transmission lines.

  2. Establishing the existence of harmonically-spaced lines in gamma-ray burst spectra using Bayesian inference. [GB 870303

    SciTech Connect

    Graziani, C.; Lamb, D.Q. ); Loredo, T.J. ); Fenimore, E.E. ); Murakami, T. ); Yoshida, A. )

    1993-07-05

    We use a rigorous method derived from Bayesian inference to establish the existence of lines in the spectra of [gamma]-ray bursts. Line detection involves a comparison of nested models. The method amounts to the calculation of the odds [ital O] favoring models with lines over models without lines. [ital O] is given by the product of the maximum likelihood ratio and a second factor which includes the ratio of the posterior uncertainty of the line parameters to their prior uncertainty. The maximum likelihood ratio always favors the more complex model, since the likelihood of the more complex model can never be larger than that of the simpler model. The second factor penalizes the more complex model, since the posterior uncertainty for the extra parameters is generally smaller than their prior uncertainty. Thus an Ockham's Razor'' automatically appears in Bayesian model comparison.

  3. Evaluaton of working techniques using teleoperation for power line maintenance

    NASA Astrophysics Data System (ADS)

    Lessard, Jean; Robert, Jean-Marc; Rondot, Pascale

    1995-12-01

    The focus of this study is the application of teleoperation to live-line maintenance work on power distribution lines. The research team's objectives are to measure and compare human performance, the levels of mental workload and the degree of satisfaction corresponding to three working techniques: the hot-stick technique (S), the direct-vision teleoperation technique with and without force feedback (T1 and T2, respectively) and the ground-level teleoperation technique (G). Three linemen with substantial experience with S, little experience with T1 and none with T2 or G took part in a study in which they had to perform a typical task with each of the three techniques. The results show that, compared to S, the productivity ratios for teleoperation are approximately 0.6 for T1, 0.5 for T2 and 0.3 for G. Extrapolation of the results shows that these productivity levels will increase with practice but not to the point where the teleoperation techniques would be as rapid as the hot- stick technique. Technical improvements in the near future are expected to help increase these ratios. The mental workload is higher with T2 and G than with S and T1. Lastly, T1 is the preferred technique and T2 the least appreciated.

  4. Harmonic phase interference for the detection of tag line crossings and beyond in homogeneous strain analysis of cardiac tagged MRI data.

    PubMed

    Bilgen, Mehmet

    2010-12-01

    Homogenous strain analysis (HSA) was developed to evaluate regional cardiac function using tagged cine magnetic resonance images of heart. Current cardiac applications of HSA are however limited in accurately detecting tag intersections within the myocardial wall, producing consistent triangulation of tag cells throughout the image series and achieving optimal spatial resolution due to the large size of the triangles. To address these issues, this article introduces a harmonic phase (HARP) interference method. In principle, as in the standard HARP analysis, the method uses harmonic phases associated with the two of the four fundamental peaks in the spectrum of a tagged image. However, the phase associated with each peak is wrapped when estimated digitally. This article shows that special combination of wrapped phases results in an image with unique intensity pattern that can be exploited to automatically detect tag intersections and to produce reliable triangulation with regularly organized partitioning of the mesh for HSA. In addition, the method offers new opportunities and freedom for evaluating myocardial function when the power and angle of the complex filtered spectra are mathematically modified prior to computing the phase. For example, the triangular elements can be shifted spatially by changing the angle and/or their sizes can be reduced by changing the power. Interference patterns obtained under a variety of power and angle conditions were presented and specific features observed in the results were explained. Together, the advanced processing capabilities increase the power of HSA by making the analysis less prone to errors from human interactions. It also allows strain measurements at higher spatial resolution and multi-scale, thereby improving the display methods for better interpretation of the analysis results. PMID:21110236

  5. A Novel Ku-Band/Ka-Band and Ka-Band/E-Band Multimode Waveguide Couplers for Power Measurement of Traveling-Wave Tube Amplifier Harmonic Frequencies

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.; Simons, Rainee N.

    2015-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler, fabricated from two dissimilar frequency band waveguides, is capable of isolating power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT) amplifier. Test results from proof-of-concept demonstrations are presented for a Ku-band/Ka-band MDC and a Ka-band/E-band MDC. In addition to power measurements at harmonic frequencies, a potential application of the MDC is in the design of a satellite borne beacon source for atmospheric propagation studies at millimeter-wave (mm-wave) frequencies (Ka-band and E-band).

  6. High-power diode-directly-pumped tenth-order harmonic mode-locked TEM00 Nd:YVO4 laser with 1 GHz repetition rate

    NASA Astrophysics Data System (ADS)

    Li, F.-Q.; Zong, N.; Han, L.; Tian, C.-Y.; Bo, Y.; Peng, Q.-J.; Cui, D.-F.; Xu, Z.-Y.

    2011-02-01

    A high-efficiency high-power diode-directly-pumped tenth-order harmonic mode-locked TEM00 Nd:YVO4 laser with 1 GHz repetition rate was first demonstrated. The maximum output power was 10.4 W with optical-optical efficiency of 41.8% and slope efficiency of 78.1%, respectively, the pulse width was about 30 ps at the output power of 9.6 W. Based on the large third-order nonlinearity of Nd:YVO4, the tenth-order harmonic mode-locked pulses were induced by the intensity-dependent Kerr effect and the cooperative action of counter-propagating pulses colliding in the laser crystal for a colliding-pulse-modelocking-like cavity. The pulses were further modulated by a semiconductor saturable absorber mirror.

  7. Harmonic multiplication using resonant tunneling

    NASA Technical Reports Server (NTRS)

    Sollner, T. C. L. G.; Brown, E. R.; Goodhue, W. D.; Correa, C. A.

    1988-01-01

    This paper demonstrates the use of resonant-tunneling diodes as varistors for harmonic multiplication. It is shown that efficient odd-harmonic conversion is possible and that even harmonics do not appear because of the antisymmetry of the current-voltage (I-V) curve. It is also shown that, with the proper choice of resonant-tunneling structure and pump amplitude, most of the harmonic output power can be confined to a single odd-harmonic frequency. Fifth-harmonic multiplication was demonstrated with an output at 21.75 GHz and a power conversion efficiency of 0.5 percent, and a fifth-harmonic efficiency of 2.7 percent was achieved in a circuit simulation using an improved I-V curve.

  8. Biological effects of power line fields: New York State Power Lines Project Scientific Advisory Panel: Final report

    SciTech Connect

    Ahlbom, A.; Albert, E.N.; Fraser-Smith, A.C.; Grodzinsky, A.J.; Marron, M.T.; Martin, A.O.; Persinger, M.A.; Shelanski, M.L.; Wolpow, E.R.

    1987-07-01

    The New York State Power Lines Project was established to conduct research and to review the scientific literature to determine whether health hazards of electric and magnetic fields are possible. Particular attention was directed to the fields generated by 765-kV overhead transmission lines. The research program provided support to 16 research groups studying human, animal and isolated cell sensitivity to electric and magnetic fields. No effects were found on reproduction, growth or development. Several studies showed no evidence of genetic or chromosomal damage that might lead to inherited effects or cause cancer. While most measurements of behavior and brain function did not demonstrate changes, some did show changes that were small but consistent. Some of these appear to result from changes in body rhythms, and might interfere with normal sleep patterns. There were also changes in pain responses and in the ability of rats to learn. A more serious concern comes from a study of cancer in children suggesting that children with leukemia and brain cancer are more likely to live in homes where there are elevated 60-Hz magnetic field levels. Although much more research is needed before the question whether the magnetic fields actually cause or promote cancer can be resolved, the basis for such an hypothesis is now established. 159 refs., 12 figs., 7 tabs.

  9. Design of a high-power, high-gain, 2nd harmonic, 22.848 GHz gyroklystron

    NASA Astrophysics Data System (ADS)

    Veale, M.; Purohit, P.; Lawson, W.

    2013-08-01

    In this paper we consider the design of a four-cavity, high-gain K-band gyroklystron experiment for high gradient structure testing. The frequency doubling gyroklystron utilizes a beam voltage of 500 kV and a beam current of 200 A from a magnetron injection gun (MIG) originally designed for a lower-frequency device. The microwave circuit features input and gain cavities in the circular TE011 mode and penultimate and output cavities that operate at the second harmonic in the TE021 mode. We investigate the MIG performance and study the behavior of the circuit for different values of perpendicular to parallel velocity ratio (α = V⊥ / Vz). This microwave tube is expected to be able to produce at least 20 MW of power in 1μs pulses at a repetition rate of at least 120 Hz. A maximum efficiency of 26% and a large signal gain of 58 dB under zero-drive stable conditions were simulated for a velocity ratio equal to 1.35.

  10. Design of a high-power, high-gain, 2nd harmonic, 22.848 GHz gyroklystron

    SciTech Connect

    Veale, M.; Purohit, P.; Lawson, W.

    2013-08-15

    In this paper we consider the design of a four-cavity, high-gain K-band gyroklystron experiment for high gradient structure testing. The frequency doubling gyroklystron utilizes a beam voltage of 500 kV and a beam current of 200 A from a magnetron injection gun (MIG) originally designed for a lower-frequency device. The microwave circuit features input and gain cavities in the circular TE{sub 011} mode and penultimate and output cavities that operate at the second harmonic in the TE{sub 021} mode. We investigate the MIG performance and study the behavior of the circuit for different values of perpendicular to parallel velocity ratio (α= V{sub ⊥}/ V{sub z}). This microwave tube is expected to be able to produce at least 20 MW of power in 1μs pulses at a repetition rate of at least 120 Hz. A maximum efficiency of 26% and a large signal gain of 58 dB under zero-drive stable conditions were simulated for a velocity ratio equal to 1.35.

  11. 29 CFR 1926.1408 - Power line safety (up to 350 kV)-equipment operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... person with respect to electrical power transmission and distribution confirms that a line is insulated... or registered professional engineer who is a qualified person with respect to electrical power... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (up to 350 kV)-equipment operations....

  12. 29 CFR 1926.1408 - Power line safety (up to 350 kV)-equipment operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... person with respect to electrical power transmission and distribution confirms that a line is insulated... or registered professional engineer who is a qualified person with respect to electrical power... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (up to 350 kV)-equipment operations....

  13. Power Lines and Crops Can Be Good Neighbors

    SciTech Connect

    2010-08-01

    Two of the Pacific Northwest’s greatest economic assets are its wealth of agriculture and its clean and reliable electricity fueled largely by hydropower. Sometimes the two intersect. Transmission lines carrying electricity to the region’s farms, businesses and homes must, of necessity, span large areas where people grow crops and orchards. To ensure a safe and reliable flow of electricity across these expanses, trees and other vegetation must be managed to certain standards. At the same time, the Bonneville Power Administration — which owns and operates three-quarters of the region’s high-voltage transmission — recognizes the importance of our region’s agricultural bounty. We are committed to working with individuals and agricultural communities to facilitate ongoing land-use activities in transmission rights-of-way as long as those uses are compatible with transmission safety and reliability standards. Our goal with vegetation management is to keep you and your property safe while protecting the reliability of our region’s electricity system. By working together, BPA and landowners can protect the system and public safety.

  14. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid.

    PubMed

    Byambasuren, Bat-Erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-01-01

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results. PMID:26907274

  15. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid

    PubMed Central

    Byambasuren, Bat-erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-01-01

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results. PMID:26907274

  16. Control Quality of a Feedback Control System under Cyclostationary Noise in Power Line Communication

    NASA Astrophysics Data System (ADS)

    Carrizo, Cesar; Kobayashi, Kentaro; Okada, Hiraku; Katayama, Masaaki

    This paper discusses a control system that employs a power line to transfer signals to control the motion of a single machine, and explores the influence of packet losses on the quality of the control. As an example of a controlled system, a controller with a rotary inverted pendulum as a controlled object, is considered. The feedback loop in between is the power line. The control performance is evaluated in the power line cyclostationary noise environment and compared against the performance in a stationary noise environment. As a result, it is confirmed that the power line and its cyclostationary noise features present an advantage against transmission in a channel with stationary noise.

  17. a Meteorological Risk Assessment Method for Power Lines Based on GIS and Multi-Sensor Integration

    NASA Astrophysics Data System (ADS)

    Lin, Zhiyong; Xu, Zhimin

    2016-06-01

    Power lines, exposed in the natural environment, are vulnerable to various kinds of meteorological factors. Traditional research mainly deals with the influence of a single meteorological condition on the power line, which lacks of comprehensive effects evaluation and analysis of the multiple meteorological factors. In this paper, we use multiple meteorological monitoring data obtained by multi-sensors to implement the meteorological risk assessment and early warning of power lines. Firstly, we generate meteorological raster map from discrete meteorological monitoring data using spatial interpolation. Secondly, the expert scoring based analytic hierarchy process is used to compute the power line risk index of all kinds of meteorological conditions and establish the mathematical model of meteorological risk. By adopting this model in raster calculator of ArcGIS, we will have a raster map showing overall meteorological risks for power line. Finally, by overlaying the power line buffer layer to that raster map, we will get to know the exact risk index around a certain part of power line, which will provide significant guidance for power line risk management. In the experiment, based on five kinds of observation data gathered from meteorological stations in Guizhou Province of China, including wind, lightning, rain, ice, temperature, we carry on the meteorological risk analysis for the real power lines, and experimental results have proved the feasibility and validity of our proposed method.

  18. Second harmonic inversion for ultrasound contrast harmonic imaging

    NASA Astrophysics Data System (ADS)

    Pasovic, Mirza; Danilouchkine, Mike; Faez, Telli; van Neer, Paul L. M. J.; Cachard, Christian; van der Steen, Antonius F. W.; Basset, Olivier; de Jong, Nico

    2011-06-01

    Ultrasound contrast agents (UCAs) are small micro-bubbles that behave nonlinearly when exposed to an ultrasound wave. This nonlinear behavior can be observed through the generated higher harmonics in a back-scattered echo. In past years several techniques have been proposed to detect or image harmonics produced by UCAs. In these proposed works, the harmonics generated in the medium during the propagation of the ultrasound wave played an important role, since these harmonics compete with the harmonics generated by the micro-bubbles. We present a method for the reduction of the second harmonic generated during nonlinear-propagation-dubbed second harmonic inversion (SHI). A general expression for the suppression signals is also derived. The SHI technique uses two pulses, p' and p'', of the same frequency f0 and the same amplitude P0 to cancel out the second harmonic generated by nonlinearities of the medium. Simulations show that the second harmonic is reduced by 40 dB on a large axial range. Experimental SHI B-mode images, from a tissue-mimicking phantom and UCAs, show an improvement in the agent-to-tissue ratio (ATR) of 20 dB compared to standard second harmonic imaging and 13 dB of improvement in harmonic power Doppler.

  19. Fast Power Line Detection and Localization Using Steerable Filter for Active Uav Guidance

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Mejias, L.; Li, Z.

    2012-08-01

    In this paper we present a fast power line detection and localisation algorithm as well as propose a high-level guidance architecture for active vision-based Unmanned Aerial Vehicle (UAV) guidance. The detection stage is based on steerable filters for edge ridge detection, followed by a line fitting algorithm to refine candidate power lines in images. The guidance architecture assumes an UAV with an onboard Gimbal camera. We first control the position of the Gimbal such that the power line is in the field of view of the camera. Then its pose is used to generate the appropriate control commands such that the aircraft moves and flies above the lines. We present initial experimental results for the detection stage which shows that the proposed algorithm outperforms two state-of-the-art line detection algorithms for power line detection from aerial imagery.

  20. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  1. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  2. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  3. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  4. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  5. Multi-MW 22.8 GHz Harmonic Multiplier - RF Power Source for High-Gradient Accelerator R&D

    SciTech Connect

    Jay L. Hirshfield

    2012-07-26

    Electrodynamic and particle simulation studies have been carried out to optimize design of a two-cavity harmonic frequency multiplier, in which a linear electron beam is energized by rotating fields near cyclotron resonance in a TE111 cavity in a uniform magnetic field, and in which the beam then radiates coherently at the nth harmonic into a TEn11 output cavity. Examples are worked out in detail for 7th and 2nd harmonic converters, showing RF-to-RF conversion efficiencies of 45% and 88%, respectively at 19.992 GHz (K-band) and 5.712 GHz (C-band), for a drive frequency of 2.856 GHz. Details are shown of RF infrastructure (S-band klystron, modulator) and harmonic converter components (drive cavity, output cavities, electron beam source and modulator, beam collector) for the two harmonic converters to be tested. Details are also given for the two-frequency (S- and C-band) coherent multi-MW test stand for RF breakdown and RF gun studies.

  6. Power line emission 50/60 Hz and Schumann resonances observed by microsatellite Chibis-M in the Earth's ionosphere

    NASA Astrophysics Data System (ADS)

    Dudkin, Denys; Pilipenko, Vyacheslav; Dudkin, Fedir; Pronenko, Vira; Klimov, Stanislav

    2015-04-01

    The overhead power lines are the sources of intense wideband electromagnetic (EM) emission, especially in ELF-VLF range, because of significant length (up to a few thousand kilometers) and strong 50/60 Hz currents with noticeable distortion. The radiation efficiency of the power line emission (PLE) increases with the harmonic order, so they are well observed by ground-based EM sensors. However their observations by low orbiting satellites (LEO) are very rare, particularly at basic harmonic 50/60 Hz, because of the ionospheric plasma opacity in ELF band. The Schumann resonance (SR) is the narrow-band EM noise that occurs due to the global thunderstorm activity in the Earth-ionosphere cavity. The first five eigenmodes of the SR are 7.8, 14.3, 20.8, 27.3 and 33.8 Hz and, thus, SR harmonics are also strongly absorbed by the Earth ionosphere. The published numerical simulations show that the penetration depth of such an ELF emission into the Earth's ionosphere is limited to 50-70 km for electric field and 120-240 km for magnetic field. From this follows, that PLE and SR can hardly ever be detected by LEO satellites, i.e. above the F-layer of ionosphere. In spite of this fact, these emissions were recently observed with use of the electric field antennas placed on the satellites C/NOFS (USA) and Chibis-M (Russia). Microsatellite Chibis-M was launched on January 24, 2012, at 23:18:30 UTC from the cargo ship "Progress M-13M" to circular orbit with altitude ~500 km and inclination ~52° . Chibis-M mass is about 40 kg where one third is a scientific instrumentation. The dimensions of the microsatellite case are 0.26x0.26x0.54 m with the outside mounted solar panels, service and scientific instrumentation. The main scientific objective of Chibis-M is the theoretical model verification for the atmospheric gamma-ray bursts. It requires the study of the accompanying EM processes such as the plasma waves produced by the lightning discharges in the VLF band. Chibis-M decayed on 15

  7. 78 FR 55249 - Grand Valley Rural Power Lines, Inc., Holy Cross Electric Association, Inc., Intermountain Rural...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-10

    ... Energy Regulatory Commission Grand Valley Rural Power Lines, Inc., Holy Cross Electric Association, Inc., Intermountain Rural Electric Association, Inc., Yampa Valley Electric Association, Inc. v. Public Service.... 824, 824(e) and 825(e) 2013, Grand Valley Rural Power Lines, Inc., Holy Cross Electric...

  8. Power Line Damage, Electrical Outages Reduced in the ''Sleet Belt'': NICE3 Steel Project Fact Sheet

    SciTech Connect

    2000-04-25

    The AR Windamper System was developed through a grant from the Inventions and Innovation Program, to protect power transmission lines in sleet belt states and provinces by eliminating the ''galloping'' phenomenon. Wind damping products minimize power outages and reduce repair costs to transmission lines.

  9. Research of Characteristics of the Low Voltage Power Line in Underground Coal Mine

    NASA Astrophysics Data System (ADS)

    Wei, Shaoliang; Qin, Shiqun; Gao, Wenchang; Cheng, Fengyu; Cao, Zhongyue

    The power line communications (PLCs) can count on existing electrical connections reaching each corner in the locations where such applications are required, so signal transmission over power lines is nowadays gaining more and more interest for applications like internet. The research of characteristics of the low voltage power line is the fundamental and importance task. This work presents a device to test the characteristics of the low voltage power line. The low voltage power line channel characteristics overground and the channel characteristics underground were tested in using this device. Experiments show that, the characteristics are different between the PLCs channel underground coal mine and the PLC channel overground. Different technology should be adopted to structure the PLCs channel model underground coal mine and transmit high speed digital signal. But how to use the technology better to the high-speed digital communication under coal mine is worth of further studying.

  10. Results of the harmonics measurement program at the John F. Long photovoltaic house

    SciTech Connect

    Campen, G.L.

    1982-03-01

    Photovoltaic (PV) systems used in single-family dwellings require an inverter to act as an interface between the direct-current (dc) power output of the PV unit and the alternating-current (ac) power needed by house loads. A type of inverter known as line-commutated injects harmonic currents on the ac side and requires large amounts of reactive power. Large numbers of such PV installations could lead to unacceptable levels of harmonic voltages on the utility system, and the need to increase the utility's delivery of reactive power could result in significant cost increases. The harmonics and power-factor effects are examined for a single PV installation using a line-commutated inverter. The data were obtained during a five-day measurement program conducted at the John F. Long House, which is a prototype residential PV installation located in Phoenix, Arizona. The magnitude and phase of various currents and voltages from the fundamental to the 13th harmonic were recorded both with and without the operation of the PV system. The inverter can be looked upon as an ideal current source that injects definable amounts of current at any particular harmonic frequency; the harmonic currents that were normally conducted by the house loads underwent very little change as a result of currents injected by the inverter; the harmonic voltages seen by the house loads were slightly altered due to the passage of the inverter harmonic currents through system impedances, but no effect on the voltage harmonics was observed at the distribution transformer primary; and the inverter's reactive power demands more than doubled the maximum demand that would be expected for a normal home. Sufficient information was obtained to provide for a conservative modeling of a representative PV system to be used in a computer program designed to evaluate the effects of larger concentrations of PV systems.

  11. Analysis of crustal structure of Venus utilizing residual Line-of-Sight (LOS) gravity acceleration and surface topography data. A trial of global modeling of Venus gravity field using harmonic spline method

    NASA Technical Reports Server (NTRS)

    Fang, Ming; Bowin, Carl

    1992-01-01

    To construct Venus' gravity disturbance field (or gravity anomaly) with the spacecraft-observer line of site (LOS) acceleration perturbation data, both a global and a local approach can be used. The global approach, e.g., spherical harmonic coefficients, and the local approach, e.g., the integral operator method, based on geodetic techniques are generally not the same, so that they must be used separately for mapping long wavelength features and short wavelength features. Harmonic spline, as an interpolation and extrapolation technique, is intrinsically flexible to both global and local mapping of a potential field. Theoretically, it preserves the information of the potential field up to the bound by sampling theorem regardless of whether it is global or local mapping, and is never bothered with truncation errors. The improvement of harmonic spline methodology for global mapping is reported. New basis functions, a singular value decomposition (SVD) based modification to Parker & Shure's numerical procedure, and preliminary results are presented.

  12. A second harmonic geomagnetic field line resonance at the inner edge of the plasma sheet - GEOS 1, ISEE 1, and ISEE 2 observations

    NASA Technical Reports Server (NTRS)

    Hughes, W. J.; Grard, R. J. L.

    1984-01-01

    A description is provided of observations made by GEOS 1, ISEE 1, and ISEE 2 of a hydromagnetic wave with a period approximately 90 s observed near 0200 LT between L = 9 and L = 6, close to the measured inner boundary of the plasma sheet. The wave magnetic oscillations perpendicular to and along the ambient field had similar amplitudes. Using primarily the transverse magnetic components, it is shown that the wave is a second harmonic resonance of the local geomagnetic field lines. ISEE 1 and 2 observed the opposite sense of polarization for about 30 min, although the spacecraft were separated by only 9 min in their orbit; this remarkable feature cannot be explained by either a stationary spatial boundary or a simple temporal boundary but could result from a rapid movement of the resonant region. It is argued that the most likely energy source is bounce resonance with medium energy (approximately 5 keV) ions. Calculations of the wave Poynting vector at ISEE 1 support this conclusion.

  13. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... professional engineer who is a qualified person with respect to electrical power transmission and distribution. ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926... Construction § 1926.1409 Power line safety (over 350 kV). The requirements of § 1926.1407 and § 1926.1408...

  14. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... professional engineer who is a qualified person with respect to electrical power transmission and distribution. ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926... Construction § 1926.1409 Power line safety (over 350 kV). The requirements of § 1926.1407 and § 1926.1408...

  15. Power market analysis and potential revenues of new transmission lines in a deregulated environment.

    SciTech Connect

    Koritarov, V. S.; Veselka, T. D.; Trouille, B.

    2002-05-15

    This paper describes an approach that was developed to analyze the market potential for power transactions via proposed transmission lines among the electric power utilities of Macedonia, Bulgaria, and Albania. The approach uses an integrated modeling framework consisting of several computer models that estimate the financial and economic benefits of constructing new transmission lines. The integrated model simulates open power markets under several scenarios that include cases with and without the proposed interconnections. The approach estimates power transactions among the three Balkan utility systems and the benefits of coordinated or joint system operations, including short-term power sales agreements.

  16. Application of a power line maintenance information system using OPGW to the Nishi-Gunma UHV line

    SciTech Connect

    Ooura, K.; Kanemaru, K.; Matsubara, R.; Ibuki, S.

    1995-01-01

    Tokyo Electric Power Company, Inc. began operation of the Nishi-Gunma UHV trunk line, the first 1,000 kV-designed power line in Japan, in April, 1992. This line is expected to be the key line in a major trunk-line system that is being developed. It traverses high-altitude mountainous areas subject to severe environmental and meteorological conditions for a long distance. A system using Composite Fiber-optic Overhead Ground Wire (OPGW) is constructed to obtain precise information on this line for maintenance purposes. This system comprises three major functions; (1) meteorological and facility`s monitoring for gathering meteorological data on such elements as winds, and icing and snow accretion, and for evaluating the corresponding reaction of the components such as conductor tension, and strain In the tower structure, (2) Industrial TV (ITV) monitoring for visual observation of weather, surrounding conditions and site facilities, and (3) fault section location for pinpointing faults quickly and determining the maintenance office that should respond to the faults. This Is done by estimating the fault section accurately around the boundaries of the maintenance jurisdictions. This paper describes the development of these functions and results obtained from practical operation.

  17. Gain Purchasing Power the Newfangled Way--On-Line.

    ERIC Educational Resources Information Center

    Milshtein, Amy

    1999-01-01

    Examines how San Diego State University uses computers to cut purchasing costs and boost efficiency and whether their solution can work for other business-to-business needs. How the school developed the totally self-sustaining, on-line and on-time purchasing system is discussed, including solutions to start-up problems. (GR)

  18. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1994-05-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this booklet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

  19. An algorithm for power line detection and warning based on a millimeter-wave radar video.

    PubMed

    Ma, Qirong; Goshi, Darren S; Shih, Yi-Chi; Sun, Ming-Ting

    2011-12-01

    Power-line-strike accident is a major safety threat for low-flying aircrafts such as helicopters, thus an automatic warning system to power lines is highly desirable. In this paper we propose an algorithm for detecting power lines from radar videos from an active millimeter-wave sensor. Hough Transform is employed to detect candidate lines. The major challenge is that the radar videos are very noisy due to ground return. The noise points could fall on the same line which results in signal peaks after Hough Transform similar to the actual cable lines. To differentiate the cable lines from the noise lines, we train a Support Vector Machine to perform the classification. We exploit the Bragg pattern, which is due to the diffraction of electromagnetic wave on the periodic surface of power lines. We propose a set of features to represent the Bragg pattern for the classifier. We also propose a slice-processing algorithm which supports parallel processing, and improves the detection of cables in a cluttered background. Lastly, an adaptive algorithm is proposed to integrate the detection results from individual frames into a reliable video detection decision, in which temporal correlation of the cable pattern across frames is used to make the detection more robust. Extensive experiments with real-world data validated the effectiveness of our cable detection algorithm. PMID:21652287

  20. An LSPR fiber optic sensor based on in-line micro-holes fabricated by a second harmonic 400nm femtosecond laser

    NASA Astrophysics Data System (ADS)

    Shiraishi, Masahiko; Goya, Kenji; Seki, Atsushi; Watanabe, Kazuhiro

    2016-02-01

    In this study, we have proposed a novel type of localized surface plasmon resonance (LSPR) fiber optic sensor based on in-line/pico-liter micro-holes which can be experimentally fabricated into the fiber waveguide by using a second harmonic 400 nm femtosecond laser. A repetitive pulse train of 1 kHz with a pulse width of 350 fs was irradiated onto a MMGI fiber optic to make three holes that penetrate through the fiber core and work as spectroscopic-microfluidic flow cells. In order to induce the interaction between transmitted light and gold nanoparticles (GNPs) adhered on the inner surface of the flow cells, micro-holes were designed to be the width of approximately 50 μm, along a direction perpendicular to an optical axis of an optical fiber. GNPs with approximately 100 nm of particle diameter adhered onto the inner surface according to 3-aminopropyltriethoxy silane treatment. The transmitted light through the micro-holes was obtained by optical instruments consisted of a white light source and an optical spectrum analyzer. In order to obtain the reference spectrum, the optical spectrum was acquired before dipping the sensor into the GNPs solution. After 30 min of immersing the sensor portion into the GNPs solution, the optical spectrum was also obtained. The reference spectrum which was considered as the baseline, was set to zero and then, the absorbance spectrum was calculated. The absorbance peak at a wavelength of 537 nm occurred in an air condition in the sensing area, which seemed like the resonance peak based on the LSPR.

  1. 77 FR 38793 - Grand Valley Rural Power Lines, Inc., Yampa Valley Electric Association, Inc., Intermountain...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ... Energy Regulatory Commission Grand Valley Rural Power Lines, Inc., Yampa Valley Electric Association, Inc., Intermountain Rural Electric Association, Tri-State Generation and Transmission Association, Inc. v. Public... Association, Inc., Intermountain Rural Electric Association, and Tri-State Generation and...

  2. The Power of Quantum Systems on a Line

    NASA Astrophysics Data System (ADS)

    Aharonov, Dorit; Gottesman, Daniel; Irani, Sandy; Kempe, Julia

    2009-04-01

    We study the computational strength of quantum particles (each of finite dimensionality) arranged on a line. First, we prove that it is possible to perform universal adiabatic quantum computation using a one-dimensional quantum system (with 9 states per particle). This might have practical implications for experimentalists interested in constructing an adiabatic quantum computer. Building on the same construction, but with some additional technical effort and 12 states per particle, we show that the problem of approximating the ground state energy of a system composed of a line of quantum particles is QMA-complete; QMA is a quantum analogue of NP. This is in striking contrast to the fact that the analogous classical problem, namely, one-dimensional MAX-2-SAT with nearest neighbor constraints, is in P. The proof of the QMA-completeness result requires an additional idea beyond the usual techniques in the area: Not all illegal configurations can be ruled out by local checks, so instead we rule out such illegal configurations because they would, in the future, evolve into a state which can be seen locally to be illegal. Our construction implies (assuming the quantum Church-Turing thesis and that quantum computers cannot efficiently solve QMA-complete problems) that there are one-dimensional systems which take an exponential time to relax to their ground states at any temperature, making them candidates for being one-dimensional spin glasses.

  3. Harmonic Fractions and an Integer Power Law to Demonstrate a Relationship of the Neutron to the Properties of Hydrogen and Cosmic Observables

    NASA Astrophysics Data System (ADS)

    Chakeres, D. W.; Vento, R.; Panchenko, D. I.; Tobar, J. A.; Moses, S. S.; Andrianarijaona, V. M.

    Power laws and harmonic oscillator systems represent a ubiquitous relationship among many physical phenomena. This study demonstrates a close power law relationship of the annihilation frequency of the neutron, approximately 2.27 ×1023 Hz, when used as a dimensionless base, to fundamental quantum properties of hydrogen and present-day cosmic observables. The following set of the three smallest integers: {-1, 0, 1}, and the set of partial harmonic fractions: {3/2, +/-1/2, +/-2/3, -3/4, +/-4/5}, are associated with each physical entity investigated as a frequency equivalent. They are listed as follows: twice the maximum energy of a cosmic ray, 3/2; the base identity of the neutron, 1; the Bohr radius, 4/5; Rydberg's constant, 2/3; twice the peak spectral radiance of cosmic microwave background radiation, 1/2; Planck's constant, 0; the Sun's galactic radius, -1/2; the Sun's galactic period, -2/3; Hubble's constant, -3/4; the dimension of the observable universe, -4/5; and twice the gravitational binding energy of the electron in hydrogen, -1. When viewed in the physically equivalent frequency domain, the neutron partitions an abundance of physical constants from the very small to the very large.

  4. Avian behavior and mortality at power lines in coastal South Carolina

    USGS Publications Warehouse

    Savereno, A.J.; Savereno, L.A.; Boettcher, R.; Haig, S.M.

    1996-01-01

    We compared avian behavior and mortality associated with two 115-kV transmission lines on the central South Carolina coast during 3,392 hours of observation from May 1991 through May 1994. One line was marked with 30-cm-diameter yellow aviation markers. The second line was unmarked, but was similar in most other aspects. We conducted ground searches (n = 445) beneath each line year-round to document avian mortality due to power-line collisions. At marked lines, birds that approached at line height changed behavior more at unmarked lines (P< 0.001), and fewer crossed between static and conductor wires. Collision rate was 53% lower at marked than unmarked lines. Among collisions at both sites, 82% of birds collided with static wires. Based on observed collisions and carcass recoveries, wading birds particularly appeared to be at risk. We concluded that aviation markers were effective at increasing line visibility and reducing collisions and recommend marking static wires of power lines in potentially sensitive areas.

  5. Performance analysis of radiation cooled dc transmission lines for high power space systems

    NASA Technical Reports Server (NTRS)

    Schwarze, G. E.

    1985-01-01

    As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

  6. Performance analysis of radiation cooled dc transmission lines for high power space systems

    NASA Technical Reports Server (NTRS)

    Schwarze, G. E.

    1985-01-01

    As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on hte power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

  7. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1993-11-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this pamphlet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. (BPA is the Pacific Northwest`s Federal electric power marketing agency.) First, some basic electrical terms are defined, and electric and magnetic fields are described. Next, answers are given to several questions about recent scientific studies. We then describe how BPA is addressing public concerns raised by these studies. Some important information about electrical safety follows. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this pamphlet.

  8. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or load... part of a crane/derrick, load line, or load (including rigging and lifting accessories),...

  9. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or load... part of a crane/derrick, load line, or load (including rigging and lifting accessories),...

  10. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or load... part of a crane/derrick, load line, or load (including rigging and lifting accessories),...

  11. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or load... part of a crane/derrick, load line, or load (including rigging and lifting accessories),...

  12. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all...

  13. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all...

  14. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...; wind conditions; degree of sway in the power line; lighting conditions, and other conditions affecting... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all...

  15. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all...

  16. On-line diagnostic system for power generators

    SciTech Connect

    Skormin, V.A.; Goodenough, G.S.; Huber, R.K.

    1996-12-31

    A novel approach to diagnostics of a power generator is developed. It utilizes readily available data acquired by the existing computer-based monitoring/control system. Diagnostic procedures detect various trends in the generator data and interpret these trends in the generator data and interpret these trends as changes in the generator performance caused by incipient failures. Results of trend analyses, subjected to statistical validation, facilitate failure prediction and identification thus providing the justification for service when needed. The procedures are incorporated in a diagnostic system implemented in a PC interfaced with the existing VAX-based process monitoring and control system. The diagnostic system provides graphical display of the diagnostic messages.

  17. Passive wide spectrum harmonic filter for adjustable speed drives in oil and gas industry

    NASA Astrophysics Data System (ADS)

    Al Jaafari, Khaled Ali

    Non-linear loads such as variable speed drives constitute the bulky load of oil and gas industry power systems. They are widely used in driving induction and permanent magnet motors for variable speed applications. That is because variable speed drives provide high static and dynamic performance. Moreover, they are known of their high energy efficiency and high motion quality, and high starting torque. However, these non-linear loads are main sources of current and voltage harmonics and lower the quality of electric power system. In fact, it is the six-pulse and twelve-pulse diode and thyristor rectifiers that spoil the AC power line with the dominant harmonics (5th, 7th, 11th). They provide DC voltage to the inverter of the variable speed drives. Typical problems that arise from these harmonics are Harmonic resonances', harmonic losses, interference with electronic equipment, and line voltage distortion at the Point of Common Coupling (PCC). Thus, it is necessary to find efficient, reliable, and economical harmonic filters. The passive filters have definite advantage over active filters in terms of components count, cost and reliability. Reliability and maintenance is a serious issue in drilling rigs which are located in offshore and onshore with extreme operating conditions. Passive filters are tuned to eliminate a certain frequency and therefore there is a need to equip the system with more than one passive filter to eliminate all unwanted frequencies. An alternative solution is Wide Spectrum Harmonic passive filter. The wide spectrum harmonic filters are becoming increasingly popular in these applications and found to overcome some of the limitations of conventional tuned passive filter. The most important feature of wide spectrum harmonic passive filters is that only one capacitor is required to filter a wide range of harmonics. Wide spectrum filter is essentially a low-pass filter for the harmonic at fundamental frequency. It can also be considered as a

  18. Circuit and Method for Communication Over DC Power Line

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Prokop, Norman F.

    2007-01-01

    A circuit and method for transmitting and receiving on-off-keyed (OOK) signals with fractional signal-to-noise ratios uses available high-temperature silicon- on-insulator (SOI) components to move computational, sensing, and actuation abilities closer to high-temperature or high-ionizing radiation environments such as vehicle engine compartments, deep-hole drilling environments, industrial control and monitoring of processes like smelting, and operations near nuclear reactors and in space. This device allows for the networking of multiple, like nodes to each other and to a central processor. It can do this with nothing more than the already in-situ power wiring of the system. The device s microprocessor allows it to make intelligent decisions within the vehicle operational loop and to effect control outputs to its associated actuators. The figure illustrates how each node converts digital serial data to OOK 18-kHz in transmit mode and vice-versa in receive mode; though operations at lower frequencies or up to a megahertz are within reason using this method and these parts. This innovation s technique modulates a DC power bus with millivolt-level signals through a MOSFET (metal oxide semiconductor field effect transistor) and resistor by OOK. It receives and demodulates this signal from the DC power bus through capacitive coupling at high temperature and in high ionizing radiation environments. The demodulation of the OOK signal is accomplished by using an asynchronous quadrature detection technique realized by a quasi-discrete Fourier transform through use of the quadrature components (0 and 90 phases) of the carrier frequency as generated by the microcontroller and as a function of the selected crystal frequency driving its oscillator. The detected signal is rectified using an absolute-value circuit containing no diodes (diodes being non-operational at high temperatures), and only operational amplifiers. The absolute values of the two phases of the received signal

  19. A study of electric power transmission lines for use on the lunar surface

    SciTech Connect

    Gordon, L.B.; Gaustad, K.L. )

    1991-01-10

    Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include AC and DC for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both DC and AC transmission lines.

  20. An artificial intelligence framework for on-line transient stability assessment of power systems

    SciTech Connect

    Wehenkel, L.; VanCutsem, T.; Ribbens-Pavella, M.

    1989-05-01

    A new framework is proposed to tackle the on-line transient stability problem of power systems. Based on artificial intelligence, it successively makes use of an inductive inference method to automatically build decision rules, and a deductive inference method to apply them on-line. This paper attempts to lay the foundations of an inductive inference method, where the rules explicitly relate a system's stability with relevant static parameters of it. A simple but realistic power system is treated to illustrate important features of the method and to suggest how the derived decision rules could be used on-line.

  1. Synergetic second and third harmonic electron cyclotron power absorption in TCV: experiment and Fokker-Planck modeling

    NASA Astrophysics Data System (ADS)

    Gnesin, Silvano; Goodman, Timothy; Coda, Stefano; Decker, Joan; Peysson, Yves

    2010-11-01

    The TCV tokamak is equipped with nine electron cyclotron (EC) wave gyrotron/launcher systems: six 0.5 MW in the 2nd harmonic X-mode (X2) and three 0.5 MW in the 3rd harmonic X-mode (X3). TCV experiments have been expressly devised to study the X2/X3 interplay, especially through the dynamics and transport properties of the suprathermal electron population generated primarily by X2 and its influence on the X3 wave absorption. Fokker Planck modeling of X2/X3 TCV experiments with the quasilinear fully relativistic LUKE code, coupled with the C3PO ray-tracing module and the R5X2 bremsstrahlung module, is presented here. Two series of experiments are discussed: 1) X2/X3 synergy when both X2 (82.7 GHz) and X3 (118 GHz) waves are injected into the plasma and 2) X2/X3 synergetic absorption at the same frequency (82.7 GHz). The role of suprathermal electron transport has been investigated by comparing the bremsstrahlung emission measured by a hard X-ray camera with the simulated signal.

  2. 78 FR 76140 - Extension of Public Comment Period for the Champlain Hudson Power Express Transmission Line...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ...The U.S. Department of Energy (DOE) is extending the public comment period for the Champlain Hudson Power Express Transmission Line Project Draft Environmental Impact Statement (DOE/EIS-0447). The Draft EIS evaluates the environmental impacts of DOE's proposed Federal action of issuing a Presidential permit to the Applicant, Champlain Hudson Power Express, Inc. (CHPEI), to construct, operate,......

  3. Continuous-wave ultraviolet emission through fourth-harmonic generation in a whispering-gallery resonator.

    PubMed

    Moore, Jeremy; Tomes, Matthew; Carmon, Tal; Jarrahi, Mona

    2011-11-21

    We experimentally demonstrate continuous-wave ultraviolet emission through forth-harmonic generation in a millimeter-scale lithium niobate whispering-gallery resonator pumped with a telecommunication-compatible infrared source. The whispering-gallery resonator provides four spectral lines at ultraviolet, visible, near-infrared and infrared, which are equally spaced in frequency via the cascaded-harmonic process and span a 2-octave frequency band. Our technique relies on a variable crystal poling and high transverse order of the modes for phase-matching and a resonator quality factor of over 10(7) to allow cascaded-harmonic generation up to the fourth-harmonic at input pump powers as low as 200 mW. The compact size of the whispering gallery resonator pumped at telecommunication-compatible infrared wavelengths and the low pump power requirement make our device a promising ultraviolet light source for information storage, microscopy, and chemical analysis. PMID:22109440

  4. Power lines, roads, and avian nest survival: effects on predator identity and predation intensity.

    PubMed

    DeGregorio, Brett A; Weatherhead, Patrick J; Sperry, Jinelle H

    2014-05-01

    1 Anthropogenic alteration of landscapes can affect avian nest success by influencing the abundance, distribution, and behavior of predators. Understanding avian nest predation risk necessitates understanding how landscapes affect predator distribution and behavior. 2 From a sample of 463 nests of 17 songbird species, we evaluated how landscape features (distance to forest edge, unpaved roads, and power lines) influenced daily nest survival. We also used video cameras to identify nest predators at 137 nest predation events and evaluated how landscape features influenced predator identity. Finally, we determined the abundance and distribution of several of the principal predators using surveys and radiotelemetry. 3 Distance to power lines was the best predictor of predator identity: predation by brown-headed cowbirds (Molothrus ater), corvids (Corvus sp. and Cyanocitta cristata), racers (Coluber constrictor), and coachwhips (Masticophis flagellum) increased with proximity to power lines, whereas predation by rat snakes (Elaphe obsoleta) and raptors decreased. In some cases, predator density may reliably indicate nest predation risk because racers, corvids, and cowbirds frequently used power line right-of-ways. 4 Of five bird species with enough nests to analyze individually, daily nest survival of only indigo buntings (Passerina cyanea) decreased with proximity to power lines, despite predation by most predators at our site being positively associated with power lines. For all nesting species combined, distance to unpaved road was the model that most influenced daily nest survival. This pattern is likely a consequence of rat snakes, the locally dominant nest predator (28% of predation events), rarely using power lines and associated areas. Instead, rat snakes were frequently associated with road edges, indicating that not all edges are functionally similar. 5 Our results suggest that interactions between predators and landscape features are likely to be specific to

  5. Power lines, roads, and avian nest survival: effects on predator identity and predation intensity

    PubMed Central

    DeGregorio, Brett A; Weatherhead, Patrick J; Sperry, Jinelle H

    2014-01-01

    1 Anthropogenic alteration of landscapes can affect avian nest success by influencing the abundance, distribution, and behavior of predators. Understanding avian nest predation risk necessitates understanding how landscapes affect predator distribution and behavior. 2 From a sample of 463 nests of 17 songbird species, we evaluated how landscape features (distance to forest edge, unpaved roads, and power lines) influenced daily nest survival. We also used video cameras to identify nest predators at 137 nest predation events and evaluated how landscape features influenced predator identity. Finally, we determined the abundance and distribution of several of the principal predators using surveys and radiotelemetry. 3 Distance to power lines was the best predictor of predator identity: predation by brown-headed cowbirds (Molothrus ater), corvids (Corvus sp. and Cyanocitta cristata), racers (Coluber constrictor), and coachwhips (Masticophis flagellum) increased with proximity to power lines, whereas predation by rat snakes (Elaphe obsoleta) and raptors decreased. In some cases, predator density may reliably indicate nest predation risk because racers, corvids, and cowbirds frequently used power line right-of-ways. 4 Of five bird species with enough nests to analyze individually, daily nest survival of only indigo buntings (Passerina cyanea) decreased with proximity to power lines, despite predation by most predators at our site being positively associated with power lines. For all nesting species combined, distance to unpaved road was the model that most influenced daily nest survival. This pattern is likely a consequence of rat snakes, the locally dominant nest predator (28% of predation events), rarely using power lines and associated areas. Instead, rat snakes were frequently associated with road edges, indicating that not all edges are functionally similar. 5 Our results suggest that interactions between predators and landscape features are likely to be specific to

  6. Do power lines and protected areas present a catch-22 situation for Cape vultures (Gyps coprotheres)?

    PubMed

    Phipps, W Louis; Wolter, Kerri; Michael, Michael D; MacTavish, Lynne M; Yarnell, Richard W

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area = 121,655±90,845 km(2)) and four immature (mean ±SD minimum convex polygon area = 492,300±259,427 km(2)) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa. PMID:24137496

  7. Bird behavior and mortality in relation to power lines in prairie habitats

    USGS Publications Warehouse

    Faanes, C.A.

    1987-01-01

    Research was conducted to determine the magnitude of avian mortality caused by power transmission lines in prairie habitats during the two spring and two fall migration periods between July 1980 and May 1982. Searches for dead birds were made at least twice weekly during each migration period. Study sites were selected to include 'worst-case' situations involving potentially large concentrations of birds.In total, 633 dead birds were found beneath 9.6 km of power lines. About 81% of the birds were found during fall migration. Removal of birds by scavengers was of minor, although local, importance, and observer error in finding birds was greatest in areas of dense vegetation. Total kill was estimated at 1,332 birds.Data were gathered on more than 7,000 bird flights observed in the vicinity of the power lines. Sixty-eight percent of the birds did not respond to the presence of the power lines. Flaring and climbing over the conductor or overhead ground wire occurred in about 25% of the flights. One hundred nine birds in 82 flocks were observed to collide with a power line. Of these birds, 87% flared to climb over the power line before colliding. The overhead ground wire was responsible for most deaths, as 102 of 109 birds collided with it.Whereas none of the mortality observed was considered to be biologically significant at the particular sites examined, the cumulative effect of mortality sustained from collisions with power lines may be important, particularly to populations of rare or endangered birds.

  8. Do Power Lines and Protected Areas Present a Catch-22 Situation for Cape Vultures (Gyps coprotheres)?

    PubMed Central

    Phipps, W. Louis; Wolter, Kerri; Michael, Michael D.; MacTavish, Lynne M.; Yarnell, Richard W.

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area  =  121,655±90,845 km2) and four immature (mean ±SD minimum convex polygon area  =  492,300±259,427 km2) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa. PMID:24137496

  9. Inductive energy harvesting from variable frequency and amplitude aircraft power lines

    NASA Astrophysics Data System (ADS)

    Toh, T. T.; Wright, S. W.; Kiziroglou, M. E.; Mueller, J.; Sessinghaus, M.; Yeatman, E. M.; Mitcheson, P. D.

    2014-11-01

    This paper presents a non-contact method of harvesting energy from an aircraft power line that has an AC current of variable amplitude and a frequency range of 360-800 Hz. The current and frequency characteristics of the aircraft power line are dependent on the rotation speed of the electrical generators and will therefore change during a flight. The harvester consists of an inductive coil with a ferrite core, which is interfaced to a rectifier, step-down regulator and supercapacitor. A prototype system was constructed to demonstrate reliable output voltage regulation across a supercapacitor that will supply a peak power of 100 mW under duty cycled load conditions. The system could fully charge a 40 mF supercapacitor to 3.3 V in 78 s from a power line current of 1.5 Arms at 650 Hz.

  10. The contribution of radio-frequency rectification to field-aligned losses of high-harmonic fast wave power to the divertor in the National Spherical Torus eXperiment

    SciTech Connect

    Perkins, R. J. Hosea, J. C.; Jaworski, M. A.; Diallo, A.; Bell, R. E.; Bertelli, N.; Gerhardt, S.; Kramer, G. J.; LeBlanc, B. P.; Phillips, C. K.; Podestà, M.; Roquemore, L.; Taylor, G.; Wilson, J. R.; Ahn, J.-W.; Gray, T. K.; McLean, A.; Sabbagh, S.

    2015-04-15

    The National Spherical Torus eXperiment (NSTX) can exhibit a major loss of high-harmonic fast wave (HHFW) power along scrape-off layer (SOL) field lines passing in front of the antenna, resulting in bright and hot spirals on both the upper and lower divertor regions. One possible mechanism for this loss is RF sheaths forming at the divertors. Here, we demonstrate that swept-voltage Langmuir probe characteristics for probes under the spiral are shifted relative to those not under the spiral in a manner consistent with RF rectification. We estimate both the magnitude of the RF voltage across the sheath and the sheath heat flux transmission coefficient in the presence of the RF field. Although precise comparison between the computed heat flux and infrared (IR) thermography cannot yet be made, the computed heat deposition compares favorably with the projections from IR camera measurements. The RF sheath losses are significant and contribute substantially to the total SOL losses of HHFW power to the divertor for the cases studied. This work will guide future experimentation on NSTX-U, where a wide-angle IR camera and a dedicated set of coaxial Langmuir probes for measuring the RF sheath voltage directly will quantify the contribution of RF sheath rectification to the heat deposition from the SOL to the divertor.