Science.gov

Sample records for power loss distribution

  1. Energy loss analysis of an integrated space power distribution system

    NASA Technical Reports Server (NTRS)

    Kankam, M. D.; Ribeiro, P. F.

    1992-01-01

    The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

  2. Impact Assessment of V2G on the Power Loss of Unbalanced Radial Distribution Network

    NASA Astrophysics Data System (ADS)

    Chukwu, Uwakwe Christian; Mahajan, Satish M.

    2013-08-01

    Electric distribution feeders are inherently unbalanced and therefore have potential for severe power loss. The penetration of vehicle-to-grid (V2G) into the distribution feeders is expected to impact the power losses in the system. This is a pressing issue since power loss affects the operations, economics, and quality of service for the electric power systems. In this article, the impact of V2G parking lots on power losses of a radial distribution network is investigated. Two test networks were used in the study, namely: IEEE 13 and IEEE 123 Node test feeder networks. The test feeders and the V2G facilities were modeled in Radial Distribution Analysis Package (RDAP). Load flow results provided information on the power losses of the network. Results show that for a given penetration level, the impact of 3-phase and system-wide V2G integration on the power loss results in less power losses than 1-phase V2G integration. Results also indicate that operating the entire system such that V2G facilities will not compromise "near-balanced" state of operation and will have an improved impact on the power loss than highly unbalanced operation. The results obtained will be a useful tool for studying the impact of V2G on the power loss of a distribution network.

  3. Impact of V2G on Distribution Feeder: A Power Loss Reduction Approach

    NASA Astrophysics Data System (ADS)

    Chukwu, Uwakwe C.; Mahajan, Satish M.

    2013-08-01

    The penetration of Vehicle-to-Grid (V2G) into the electrical distribution system has potential to create room for many operational benefits. A V2G facility installed on a distribution feeder line segment may affect power loss in the distribution system. Mathematical models are developed to study how magnitude of V2G reactive power injection and different mixes of uniformly distributed loads and lumped loads can impact power loss on a distribution system feeder. The V2G facilities assumed in this research are V2G parking lots with provision for injecting reactive currents into the feeder of a distribution network. It is shown that loss reduction can be greatly influenced by the pattern of loading, the amount of V2G reactive injection as well as position and number of V2G parking lot along the feeder segment. Useful results are obtained, with a promise that more than 95% power loss reduction (relative to power loss in the system without V2G installed) is possible by optimally locating a V2G parking lot along the feeder. It is observed that location and capacity injection of a V2G facility are the most critical for loss reduction. It was concluded that proper system planning and operational practice are required in order to reduce power losses.

  4. Pump combiner loss as a function of input numerical aperture power distribution

    NASA Astrophysics Data System (ADS)

    Sévigny, Benoit; Poirier, Pierre; Faucher, Mathieu

    2009-02-01

    High-power combiner designs (such as kilowatt-class combiners and beyond) are increasingly aggressive on brightness conservation in order to reduce the brightness loss of the pumps as much as possible in both direct diode combining and pump and signal coupling, especially with the advent of next-generation high-power pumps. Since most of the pump loss is due to brightness loss across the combiner, tighter designs (close to the brightness limit) are considerably more sensitive to variations in the input power distribution as a function of numerical aperture; for instance, next-generation, high-power multi-emitter pumps are likely to have larger numerical apertures than conventional single-emitter diodes. As a consequence, pump insertion loss for a given combiner design sitting close to the brightness limit should be dependant on the input power distribution. Aside from presenting a manufacturing challenge, high brightness combiners also imply more sophisticated testing to allow a deeper understanding of the loss with respect to the far-field distribution of the pump inputs and thus enable the extrapolation of loss for an arbitrary, cylindrically symmetric radiant intensity distribution. In this paper, we present a novel test method to measure loss as a function of numerical aperture (NA) fill factor using a variable NA source with square-shaped far field distributions. Results are presented for a range of combiners, such as 7x1 and 19x1 pump combiners, with different brightness ratio and fiber inputs. Combiners violating the brightness conservation equation are also characterized in order to estimate the loss as a function of input power vs. NA distribution and fill factor.

  5. Power loss of a single electron charge distribution confined in a quantum plasma

    SciTech Connect

    Mehramiz, A.; Mahmoodi, J.; Sobhanian, S.

    2011-05-15

    The dielectric tensor for a quantum plasma is derived by using a linearized quantum hydrodynamic theory. The wave functions for a nanostructure bound system have been investigated. Finally, the power loss for an oscillating charge distribution of a mixed state will be calculated, using the dielectric function formalism.

  6. High-power gyrotron traveling-wave amplifier with distributed wall losses and attenuating severs

    SciTech Connect

    Yeh, Y.S.; Shin, Y.Y.; You, Y.C.; Chen, L.K.

    2005-04-15

    Distributed-loss gyrotron traveling-wave amplifiers (gyro-TWTs) with high-gain, broadband, and millimeter-wave capabilities have been demonstrated. Most structures with distributed wall losses are stabilized in gyro-TWTs that operate at low beam currents. Attenuating severs are added to the interaction circuit of a distributed-loss gyro-TWT to prevent high beam currents that result in mode competition. Simulation results show that gyrotron backward-wave oscillations (gyro-BWOs) are not effectively suppressed by the lossy section; in contrast, the severed sections can effectively enhance the start-oscillation threshold of gyro-BWOs in the proposed gyro-TWT. Meanwhile, localized reflective oscillations seem not to occur in the gyro-TWT unless it operates at a high magnetic field or with a high interaction length. The stable gyro-TWT, operating in the low-loss TE{sub 01} mode, is predicted to yield a peak output power of 405 kW at 33 GHz with an efficiency of 20%, a saturated gain of 77 dB and a 3 dB bandwidth of 2.5 GHz for a 100 kV, 20 A electron beam with an axial velocity spread of {delta}v{sub z}/v{sub z}=5%.

  7. Influence of size distribution and field amplitude on specific loss power

    NASA Astrophysics Data System (ADS)

    Boskovic, M.; Goya, G. F.; Vranjes-Djuric, S.; Jovic, N.; Jancar, B.; Antic, B.

    2015-03-01

    Herein we present the results of specific loss power (SLP) analysis of polydisperse water based ferrofluids, Fe3O4/PEG200 and Fe3O4/PEG6000, with average Fe3O4 particle size of 9 nm and 11 nm, respectively. Specific loss power was measured in alternating magnetic field of various amplitudes and at fixed frequency of 580.5 kHz. Maximum SLP values acquired were 195 W/g for Fe3O4/PEG200 and 60 W/g for Fe3O4/PEG6000 samples. The samples were labeled as superparamagnetic by magnetization measurements, but SLP field dependence showed deviation from the behavior predicted by the commonly employed linear response theory. The scope of this theory for both samples with wide particle size distribution is discussed. Deviation from the expected behavior is explained by referring to polydisperse nature of the samples and field dependent relaxation rates.

  8. Computational analysis of the curvature distribution and power losses of metal strip in tension levellers

    NASA Astrophysics Data System (ADS)

    Steinwender, L.; Kainz, A.; Krimpelstätter, K.; Zeman, K.

    2010-06-01

    Tension levelling is employed in strip processing lines to minimise residual stresses resp. to improve the strip flatness by inducing small elasto-plastic deformations. To improve the design of such machines, precise calculation models are essential to reliably predict tension losses due to plastic dissipation, power requirements of the driven bridle rolls (located upstream and downstream), reaction forces on levelling rolls as well as strains and stresses in the strip. FEM (Finite Element Method) simulations of the tension levelling process (based on Updated Lagrangian concepts) yield high computational costs due to the necessity of very fine meshes as well as due to the severely non-linear characteristics of contact, material and geometry. In an evaluation process of hierarchical models (models with different modeling levels), the reliability of both 3D and 2D modelling concepts (based on continuum and structural elements) was proved by extensive analyses as well as consistency checks against measurement data from an industrial tension leveller. To exploit the potential of computational cost savings, a customised modelling approach based on the principle of virtual work has been elaborated, which yields a drastic reduction of degrees of freedom compared to simulations by utilising commercial FEM-packages.

  9. A study using a Monte Carlo method of the optimal configuration of a distribution network in terms of power loss sensing.

    PubMed

    Moon, Hyun Ho; Lee, Jong Joo; Choi, Sang Yule; Cha, Jae Sang; Kang, Jang Mook; Kim, Jong Tae; Shin, Myong Chul

    2011-01-01

    the distribution loss associated with power distribution systems focus on sensing aspect and distributed power generation. PMID:22164047

  10. Estimation of steady-state and transcient power distributions for the RELAP analyses of the 1963 loss-of-flow and loss-of-pressure tests at BR2.

    SciTech Connect

    Dionne, B.; Tzanos, C. P.

    2011-05-23

    To support the safety analyses required for the conversion of the Belgian Reactor 2 (BR2) from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, the simulation of a number of loss-of-flow tests, with or without loss of pressure, has been undertaken. These tests were performed at BR2 in 1963 and used instrumented fuel assemblies (FAs) with thermocouples (TC) imbedded in the cladding as well as probes to measure the FAs power on the basis of their coolant temperature rise. The availability of experimental data for these tests offers an opportunity to better establish the credibility of the RELAP5-3D model and methodology used in the conversion analysis. In order to support the HEU to LEU conversion safety analyses of the BR2 reactor, RELAP simulations of a number of loss-of-flow/loss-of-pressure tests have been undertaken. Preliminary analyses showed that the conservative power distributions used historically in the BR2 RELAP model resulted in a significant overestimation of the peak cladding temperature during the transient. Therefore, it was concluded that better estimates of the steady-state and decay power distributions were needed to accurately predict the cladding temperatures measured during the tests and establish the credibility of the RELAP model and methodology. The new approach ('best estimate' methodology) uses the MCNP5, ORIGEN-2 and BERYL codes to obtain steady-state and decay power distributions for the BR2 core during the tests A/400/1, C/600/3 and F/400/1. This methodology can be easily extended to simulate any BR2 core configuration. Comparisons with measured peak cladding temperatures showed a much better agreement when power distributions obtained with the new methodology are used.

  11. Transmission and distribution-loss analysis

    SciTech Connect

    Not Available

    1982-05-01

    A previous study developed a methodology for determining the losses in the various elements of an electric utility transmission and distribution system using only generally published system data. In that study the losses at the system peak and the average annual losses of the Niagara Mohawk Power Corporation system were calculated to illustrate the methods. Since there was little or no system loss data available at that time, the methodology of the loss calculations was not verified. The purpose of this study was to verify the methods that were proposed in the previous study. The data, estimates, assumptions, and calculation methods of the original study were checked against the actual Niagara Mohawk system data. The losses calculated in the original study were compared to the system losses derived from actual system data. Revisions to the original methods were recommended to improve the accuracy of the results. As a result of the analysis done in this study, the methods developed in the original study were revised. The revised methods provide reasonable loss calculation results for the Niagara Mohawk system. These methods along with discussions of their application are given. Also included is a description of the procedures followed to find the system losses from the actual system data. The revised loss calculation methods using the published data based on the Niagara Mohawk system data, operation, and loadings, gave reasonable results for that system, and the method may be applicable to similar systems.

  12. Exponentiated power Lindley distribution

    PubMed Central

    Ashour, Samir K.; Eltehiwy, Mahmoud A.

    2014-01-01

    A new generalization of the Lindley distribution is recently proposed by Ghitany et al. [1], called as the power Lindley distribution. Another generalization of the Lindley distribution was introduced by Nadarajah et al. [2], named as the generalized Lindley distribution. This paper proposes a more generalization of the Lindley distribution which generalizes the two. We refer to this new generalization as the exponentiated power Lindley distribution. The new distribution is important since it contains as special sub-models some widely well-known distributions in addition to the above two models, such as the Lindley distribution among many others. It also provides more flexibility to analyze complex real data sets. We study some statistical properties for the new distribution. We discuss maximum likelihood estimation of the distribution parameters. Least square estimation is used to evaluate the parameters. Three algorithms are proposed for generating random data from the proposed distribution. An application of the model to a real data set is analyzed using the new distribution, which shows that the exponentiated power Lindley distribution can be used quite effectively in analyzing real lifetime data. PMID:26644927

  13. Exponentiated power Lindley distribution.

    PubMed

    Ashour, Samir K; Eltehiwy, Mahmoud A

    2015-11-01

    A new generalization of the Lindley distribution is recently proposed by Ghitany et al. [1], called as the power Lindley distribution. Another generalization of the Lindley distribution was introduced by Nadarajah et al. [2], named as the generalized Lindley distribution. This paper proposes a more generalization of the Lindley distribution which generalizes the two. We refer to this new generalization as the exponentiated power Lindley distribution. The new distribution is important since it contains as special sub-models some widely well-known distributions in addition to the above two models, such as the Lindley distribution among many others. It also provides more flexibility to analyze complex real data sets. We study some statistical properties for the new distribution. We discuss maximum likelihood estimation of the distribution parameters. Least square estimation is used to evaluate the parameters. Three algorithms are proposed for generating random data from the proposed distribution. An application of the model to a real data set is analyzed using the new distribution, which shows that the exponentiated power Lindley distribution can be used quite effectively in analyzing real lifetime data. PMID:26644927

  14. The Power War: Male Response to Power Loss under Equality.

    ERIC Educational Resources Information Center

    Kahn, Arnold

    1984-01-01

    Analyzes the male response to anticipated loss of power as women continue to demand equality and equal power. Describes the scope of male power, and analyzes the importance of power to men in terms of the male sex-role stereotype. Hypothesizes some likely male responses to a loss of power. (BH)

  15. Industrial power distribution

    SciTech Connect

    Sorrells, M.A.

    1990-01-01

    This paper is a broad overview of industrial power distribution. Primary focus will be on selection of the various low voltage components to achieve the end product. Emphasis will be on the use of national standards to ensure a safe and well designed installation.

  16. Automated Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Thomason, Cindy; Anderson, Paul M.; Martin, James A.

    1990-01-01

    Automated power-distribution system monitors and controls electrical power to modules in network. Handles both 208-V, 20-kHz single-phase alternating current and 120- to 150-V direct current. Power distributed to load modules from power-distribution control units (PDCU's) via subsystem distributors. Ring busses carry power to PDCU's from power source. Needs minimal attention. Detects faults and also protects against them. Potential applications include autonomous land vehicles and automated industrial process systems.

  17. Localized power loss measurement using remote sensors

    SciTech Connect

    Moghaddam, A.J.; Moses, A.J. . Wolfson Centre for Magnetics Technology)

    1993-11-01

    A computerized system was designed and constructed to scan and measure localized power loss over an area of an electrical steel lamination. The local components of flux density (B) and field (H) were detected by a remote search coil and a magnetoresistive sensor respectively. The results obtained show that the power loss varies over the sample surface and the surface of individual grains. A high average loss was observed over a grain with a yaw angle of 7[degree], the minimum average loss was measured in a grain with a tilt angle of approximately 2[degree] to 3[degree]. The bulk average power loss over an area is comparable to that of a Single Strip Tester (SST).

  18. power loss in SSPX

    NASA Astrophysics Data System (ADS)

    Stewart, T. L.; Romero-Talamas, C. A.; McLean, H. S.; Correll, D. L.

    2007-11-01

    An absolute calibration has been performed on each of the seven chords of the Hα diagnostic [Z. Wang, G.A. Wurden, C.W Barnes, et al., Rev. Sci. Instrum. 72, 1059 (2001)] at SSPX. Simple models are used to estimate the total power lost to Hα radiation throughout experimental shots. Using these models, high energy shots (Te > 500 eV) are compared to low energy shots.

  19. The Unseen Power Loss: Stemming the Flow.

    ERIC Educational Resources Information Center

    Gillett, Raphael

    2002-01-01

    Outlined an estimate-substitution strategy for a test comparing two means and developed an expected-power formula for the test. Demonstrated that for empirically representative distributions of effect size in psychology, the expected power deficit is large. (SLD)

  20. Loss Reduction on Adoption of High Voltage LT Less Distribution

    NASA Astrophysics Data System (ADS)

    Tiwari, Deepika; Adhikari, Nikhileshwar Prasad; Gupta, Amit; Bajpai, Santosh Kumar

    2015-03-01

    In India there is a need to improve the quality of the electricity distribution process which has increased varying from year to year. In distribution networks, the limiting factor to load carrying capacity is generally the voltage reduction. High voltage distribution system (HVDS) is one of the steps to reduce line losses in electrical distribution network. It helps to reduce the length of low tension (LT) lines and makes the power available close to the users. The high voltage power distribution system reduces the probability of power theft by hooking HVDS suggests an increase in installation of small capacity single-phase transformers in the network which again save considerable energy. This paper is compared to existing conventional low tension distribution network with HVDS. The paper gives a clear picture of reduction in distribution losses with adoption of HVDS system. Losses Reduction of 11 kV Feeder in Nuniya (India) with adoption of HVDS have been worked out/ quantified and benefits thereby in generating capacity have discussed.

  1. Loss Reduction on Adoption of High Voltage LT Less Distribution

    NASA Astrophysics Data System (ADS)

    Tiwari, Deepika; Adhikari, Nikhileshwar Prasad; Gupta, Amit; Bajpai, Santosh Kumar

    2016-06-01

    In India there is a need to improve the quality of the electricity distribution process which has increased varying from year to year. In distribution networks, the limiting factor to load carrying capacity is generally the voltage reduction. High voltage distribution system (HVDS) is one of the steps to reduce line losses in electrical distribution network. It helps to reduce the length of low tension (LT) lines and makes the power available close to the users. The high voltage power distribution system reduces the probability of power theft by hooking HVDS suggests an increase in installation of small capacity single-phase transformers in the network which again save considerable energy. This paper is compared to existing conventional low tension distribution network with HVDS. The paper gives a clear picture of reduction in distribution losses with adoption of HVDS system. Losses Reduction of 11 kV Feeder in Nuniya (India) with adoption of HVDS have been worked out/ quantified and benefits thereby in generating capacity have discussed.

  2. Radiation power losses and opacity of mid-Z impurities

    NASA Astrophysics Data System (ADS)

    Benredjem, D.; Calisti, A.; Pain, J. C.; Gilleron, F.

    2010-08-01

    We present results on opacity and radiation losses of mid-Z impurities in ICF conditions. Two approaches were investigated. The first one is based on a detailed calculation where the atomic database is provided by the MCDF code. Then a lineshape code (PPP) based on a fast algorithm was adapted to the calculation of emissivity and opacity profiles. The second approach is a statistical one. It involves high-order moments of the radiative power losses. Atomic calculations were performed with the Cowan code. The Normal Inverse Gaussian and the Generalized Gaussian distributions were then used to calculate the radiation power loss profile.

  3. Distributed Generators Allocation in Radial Distribution Systems with Load Growth using Loss Sensitivity Approach

    NASA Astrophysics Data System (ADS)

    Kumar, Ashwani; Vijay Babu, P.; Murty, V. V. S. N.

    2016-07-01

    Rapidly increasing electricity demands and capacity shortage of transmission and distribution facilities are the main driving forces for the growth of distributed generation (DG) integration in power grids. One of the reasons for choosing a DG is its ability to support voltage in a distribution system. Selection of effective DG characteristics and DG parameters is a significant concern of distribution system planners to obtain maximum potential benefits from the DG unit. The objective of the paper is to reduce the power losses and improve the voltage profile of the radial distribution system with optimal allocation of the multiple DG in the system. The main contribution in this paper is (i) combined power loss sensitivity (CPLS) based method for multiple DG locations, (ii) determination of optimal sizes for multiple DG units at unity and lagging power factor, (iii) impact of DG installed at optimal, that is, combined load power factor on the system performance, (iv) impact of load growth on optimal DG planning, (v) Impact of DG integration in distribution systems on voltage stability index, (vi) Economic and technical Impact of DG integration in the distribution systems. The load growth factor has been considered in the study which is essential for planning and expansion of the existing systems. The technical and economic aspects are investigated in terms of improvement in voltage profile, reduction in total power losses, cost of energy loss, cost of power obtained from DG, cost of power intake from the substation, and savings in cost of energy loss. The results are obtained on IEEE 69-bus radial distribution systems and also compared with other existing methods.

  4. Power losses in liquid metal current collectors

    NASA Astrophysics Data System (ADS)

    Hurwitz, M. M.; Wallace, D. R.

    1980-05-01

    A numerical capability has been developed which will compute ohmic and viscous power losses in liquid metal current collectors. The present work extends previous analytical investigations in that semi-infinite collector geometries are no longer assumed. This new capability is based on the finite element method and makes use of electrical current densities computed by the heat transfer portion of the NASTRAN structural analysis program. Although some limitations and questions remain, a comparison between the new numerical capability and experiment shows very good agreement in the computation of the power losses.

  5. ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

    SciTech Connect

    Tuffner, Francis K.; Singh, Ruchi

    2011-08-09

    Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

  6. Optical power distribution system

    SciTech Connect

    Lalmond, R.G.

    1987-09-08

    This patent describes an apparatus for supplying electrical power to electrical components mounted on a circuit board. It consists of: a printed circuit board; electrical components mounted on the printed circuit board; electrically powered sources of optical energy; photovoltaic cell arrays; each photovoltaic cell array being mounted on a corresponding one of the electrical components to provide electrical power to the electrical component on which it is mounted; and means for coupling the optical energy from the electrically powered sources of optical energy to the photovoltaic cell arrays.

  7. Distributed Space Solar Power

    NASA Technical Reports Server (NTRS)

    Fork, Richard L.

    2001-01-01

    The objective was to assess the feasibility of safely collecting solar power at geostationary orbit and delivering it to earth. A strategy which could harness a small fraction of the millions of gigawatts of sunlight passing near earth could adequately supply the power needs of earth and those of space exploration far into the future. Light collected and enhanced both spatially and temporally in space and beamed to earth provides probably the only practical means of safe and efficient delivery of this space solar power to earth. In particular, we analyzed the feasibility of delivering power to sites on earth at a comparable intensity, after conversion to a usable form, to existing power needs. Two major obstacles in the delivery of space solar power to earth are safety and the development of a source suitable for space. We focused our approach on: (1) identifying system requirements and designing a strategy satisfying current eye and skin safety requirements; and (2) identifying a concept for a potential space-based source for producing the enhanced light.

  8. Loss of 115 kV Power

    SciTech Connect

    Smith, J.A.

    2001-08-22

    This report discusses the postulated loss of 115 kV power. Continuous electrical power to Savannah River Plant reactors is necessary to maintain water flow for heat removal and essential monitoring and control. Should power supplied to the plant 115 kV system from offsite be lost, on-site generation is sufficient to maintain all reactors in a safe shutdown mode for an indefinite period. Should on-site generators for the 115 kV grid also be lost, diesel-electric generators within each reactor building are also sufficient to maintain safe shutdown for a finite period. In all cases DC power for necessary monitoring and control would be available from battery systems with AC converter backup.

  9. Pinning Loss Power Density in Superconductors

    NASA Astrophysics Data System (ADS)

    Matsushita, Teruo

    2015-03-01

    The pinning loss power density is theoretically derived based on the resistive energy dissipation when the flux lines are driven by the Lorentz force in a superconductor. The obtained loss power density does not depend on the viscosity or flow resistivity, but is proportional to the pinning force density only, and it possesses the nature of hysteresis loss, as commonly measured in experiments. These features are predicted by the critical state model, which was recently proved theoretically. The obtained pinning force density is consistent with the prediction of the coherent potential approximation theory, a kind of statistical summation theory, for flux pinning. Thus, the irreversible properties associated with the flux pinning can be comprehensively described by these flux pinning theories. The irreversible flux pinning in the superconductor is compared with similar irreversible phenomena such as the motion of magnetic domain walls in ferromagnetic materials and the friction in mechanical systems. The possibility is also discussed for a general theoretical description of these irreversible phenomena in which the hysteresis loss occurs.

  10. Power management and distribution technology

    NASA Technical Reports Server (NTRS)

    Dickman, John Ellis

    1993-01-01

    Power management and distribution (PMAD) technology is discussed in the context of developing working systems for a piloted Mars nuclear electric propulsion (NEP) vehicle. The discussion is presented in vugraph form. The following topics are covered: applications and systems definitions; high performance components; the Civilian Space Technology Initiative (CSTI) high capacity power program; fiber optic sensors for power diagnostics; high temperature power electronics; 200 C baseplate electronics; high temperature component characterization; a high temperature coaxial transformer; and a silicon carbide mosfet.

  11. Measurements of AC Losses and Current Distribution in Superconducting Cables

    SciTech Connect

    Nguyen, Doan A; Ashworth, Stephen P; Duckworth, Robert C; Carter, Bill; Fleshler, Steven

    2011-01-01

    This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.

  12. Power Law Distribution in Education

    NASA Astrophysics Data System (ADS)

    Gupta, Hari M.; Campanha, José R.; Chavarette, Fábio R.

    We studied the statistical distribution of student's performance, which is measured through their marks, in university entrance examination (Vestibular) of UNESP (Universidade Estadual Paulista) with respect to (i) period of study-day versus night period (ii) teaching conditions - private versus public school (iii) economical conditions - high versus low family income. We observed long ubiquitous power law tails in physical and biological sciences in all cases. The mean value increases with better study conditions followed by better teaching and economical conditions. In humanities, the distribution is close to normal distribution with very small tail. This indicates that these power law tails in science subjects are due to the nature of the subjects themselves. Further and better study, teaching and economical conditions are more important for physical and biological sciences in comparison to humanities at this level of study. We explain these statistical distributions through Gradually Truncated Power law distributions. We discuss the possible reason for this peculiar behavior.

  13. Economics of heat loss for power cables

    SciTech Connect

    Cornelison, K.E.

    1982-07-01

    Energy losses occur in power cables which cause a rise in the conductor temperature. A trend toward higher allowable conductor temperatures has increased the energy losses during operation. At the same time, the costs of the energy has increased dramatically. With a given installation and load, energy costs vary inversely with the conductor size. However, initial costs vary directly with the conductor size. This relationship can be utilized to select a conductor size which minimizes the sum of the initial costs an the energy costs. This paper reviews present value techniques and identifies the level of energy costs in some particular installation configurations. An analysis is made of the marginal costs and savings available by changing the size of the conductor in a cable circuit.

  14. Aggregate size distribution of the soil loss

    NASA Astrophysics Data System (ADS)

    Szabó, Judit Alexandra; Jakab, Gergely; Szabó, Boglárka; Józsa, Sándor; Szalai, Zoltán; Centeri, Csaba

    2016-04-01

    In agricultural areas the soil erosion and soil loss estimation is vital information in long-term planning. During the initial period of the erosion a part of the soil particles and aggregates get transportable and nutrients and organic matter could be transported due to the effect of water or wind. This preliminary phase was studied with laboratory-scale rainfall simulator. Developed surface crust and aggregate size composition of the runoff was examined in six different slope-roughness-moisture content combination of a Cambisol and a Regosol. The ratio of micro- and macro aggregates in the runoff indicate the stability of the aggregates and determine the transport capacity of the runoff. Both soil samples were taken from field where the water erosion is a potential hazard. During the experiment the whole amount of runoff and sediment was collected through sieve series to a bucket to separate the micro- and macro aggregates. In case of both samples the micro aggregates dominate in the runoff and the runoff rates are similar. Although the runoff of the Regosol - with dominant >1000μm macro aggregate content - contained almost nothing but <50μm sized micro aggregates. Meanwhile the runoff of the Cambisol - with more balanced micro and macro aggregate content - contained dominantly 50-250μm sized micro aggregates and in some case remarkable ratio 250-1000μm sized macro aggregates. This difference occurred because the samples are resistant against drop erosion differently. In case of both sample the selectivity of the erosion and substance matrix redistribution manifested in mineral crusts in the surface where the quartz deposited in place while the lighter organic matter transported with the sediment. The detachment of the aggregates and the redistribution of the particles highly effect on the aggregate composition of the runoff which is connected with the quality of the soil loss. So while the estimation of soil loss quantity is more or less is easy, measuring

  15. RFQ Designs and Beam-Loss Distributions for IFMIF

    SciTech Connect

    Jameson, Robert A

    2007-01-01

    The IFMIF 125 mA cw 40 MeV accelerators will set an intensity record. Minimization of particle loss along the accelerator is a top-level requirement and requires sophisticated design intimately relating the accelerated beam and the accelerator structure. Such design technique, based on the space-charge physics of linear accelerators (linacs), is used in this report in the development of conceptual designs for the Radio-Frequency-Quadrupole (RFQ) section of the IFMIF accelerators. Design comparisons are given for the IFMIF CDR Equipartitioned RFQ, a CDR Alternative RFQ, and new IFMIF Post-CDR Equipartitioned RFQ designs. Design strategies are illustrated for combining several desirable characteristics, prioritized as minimum beam loss at energies above ~ 1 MeV, low rf power, low peak field, short length, high percentage of accelerated particles. The CDR design has ~0.073% losses above 1 MeV, requires ~1.1 MW rf structure power, has KP factor 1.7,is 12.3 m long, and accelerates ~89.6% of the input beam. A new Post-CDR design has ~0.077% losses above 1 MeV, requires ~1.1 MW rf structure power, has KP factor 1.7 and ~8 m length, and accelerates ~97% of the input beam. A complete background for the designs is given, and comparisons are made. Beam-loss distributions are used as input for nuclear physics simulations of radioactivity effects in the IFMIF accelerator hall, to give information for shielding, radiation safety and maintenance design. Beam-loss distributions resulting from a ~1M particle input distribution representative of the IFMIF ECR ion source are presented. The simulations reported were performed with a consistent family of codes. Relevant comparison with other codes has not been possible as their source code is not available. Certain differences have been noted but are not consistent over a broad range of designs and parameter range. The exact transmission found by any of these codes should be treated as indicative, as each has various sensitivities in

  16. A versatile technique to minimize electrical losses in distribution feeders

    SciTech Connect

    Kyaruzi, A.L.

    1994-12-31

    This dissertation presents a method of minimizing electrical losses in radial distribution feeders by the use of shunt capacitors. The engineering benefits of reducing peak electrical power and energy losses are compared to the costs associated with the current engineering practice of buying, installing and servicing capacitor banks in the distribution feeders. The present analysis defines this cost-benefit problem and the formulation of the problem of nonuniform feeders with different wire gauges at various feeder sections. Standard utility capacitor bank sizes are used to give a more realistic model. An original computer solution methodology based on techniques developed for this study determines: (i) Whether it is economical to install compensating capacitor banks on a particular radial distribution feeder or not. (ii) The locations at which capacitor banks should be installed. (iii) The types and sizes of capacitor banks to be installed. (iv) The time setting of switched capacitor banks. The techniques have been applied to a typical radial distribution feeder in Dar-es-Salaam, Tanzania. The results and the engineering implications of this work are discussed and recommendations for the engineering community made.

  17. High frequency power distribution system

    NASA Technical Reports Server (NTRS)

    Patel, Mikund R.

    1986-01-01

    The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.

  18. Distributed Power Electronics for PV Systems (Presentation)

    SciTech Connect

    Deline, C.

    2011-12-01

    An overview of the benefits and applications of microinverters and DC power optimizers in residential systems. Some conclusions from this report are: (1) The impact of shade is greater than just the area of shade; (2) Additional mismatch losses include panel orientation, panel distribution, inverter voltage window, soiling; (3) Per-module devices can help increase performance, 4-12% or more depending on the system; (4) Value-added benefits (safety, monitoring, reduced design constraints) are helping their adoption; and (5) The residential market is growing rapidly. Efficiency increases, cost reductions are improving market acceptance. Panel integration will further reduce price and installation cost. Reliability remains an unknown.

  19. Local control of reactive power by distributed photovoltaic generators

    SciTech Connect

    Chertkov, Michael; Turitsyn, Konstantin; Sulc, Petr; Backhaus, Scott

    2010-01-01

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the real power generated by the PVs. Using one adjustable parameter per circuit, we balance the requirements on power quality and desire to minimize thermal losses. Numerical analysis of two exemplary systems, with comparable total PV generation albeit a different spatial distribution, show how to adjust the optimization parameter depending on the goal. Overall, this local scheme shows excellent performance; it's capable of guaranteeing acceptable power quality and achieving significant saving in thermal losses in various situations even when the renewable generation in excess of the circuit own load, i.e. feeding power back to the higher-level system.

  20. Fundamental rate-loss tradeoff for optical quantum key distribution

    NASA Astrophysics Data System (ADS)

    Takeoka, Masahiro; Guha, Saikat; Wilde, Mark M.

    2014-10-01

    Since 1984, various optical quantum key distribution (QKD) protocols have been proposed and examined. In all of them, the rate of secret key generation decays exponentially with distance. A natural and fundamental question is then whether there are yet-to-be discovered optical QKD protocols (without quantum repeaters) that could circumvent this rate-distance tradeoff. This paper provides a major step towards answering this question. Here we show that the secret key agreement capacity of a lossy and noisy optical channel assisted by unlimited two-way public classical communication is limited by an upper bound that is solely a function of the channel loss, regardless of how much optical power the protocol may use. Our result has major implications for understanding the secret key agreement capacity of optical channels—a long-standing open problem in optical quantum information theory—and strongly suggests a real need for quantum repeaters to perform QKD at high rates over long distances.

  1. Measurement Of Spectral Power Distribution

    NASA Astrophysics Data System (ADS)

    Moore, J. R.

    1980-11-01

    The majority of spectroradiometers make measurements at a number of discrete wavelength settings spaced evenly across the spectrum. Many modern light sources such as fluorescent or metal halide lamps have complex line spectra which may not be properly evaluated by this method. An automated spectroradiometer system involving a non-stop spectral scan with continuous integration of the output signal from the detector is described. The method is designed to make accurate measurements of all types of spectral power distribution whether made up of lines or continuum or any mixture of the two.

  2. Power loss mechanisms in pathological tracheas.

    PubMed

    Bates, A J; Comerford, A; Cetto, R; Schroter, R C; Tolley, N S; Doorly, D J

    2016-07-26

    The effort required to inhale a breath of air is a critically important measure in assessing airway function. Although the contribution of the trachea to the total flow resistance of the airways is generally modest, pathological alterations in tracheal geometry can have a significant negative effect. This study investigates the mechanisms of flow energy loss in a healthy trachea and in four geometries affected by retrosternal goitre which can cause significant distortions of tracheal geometry including constriction and deviation with abnormal curvature. By separating out the component of energy loss related to the wall shear (frictional loss), striking differences are found between the patterns of energy dissipation in the normal and pathological tracheas. Furthermore the ratio of frictional to total loss is dramatically reduced in the pathological geometries. PMID:26686396

  3. Space station power management and distribution

    NASA Technical Reports Server (NTRS)

    Teren, F.

    1985-01-01

    The power system architecture is presented by a series of schematics which illustrate the power management and distribution (PMAD) system at the component level, including converters, controllers, switchgear, rotary power transfer devices, power and data cables, remote power controllers, and load converters. Power distribution options, reference power management, and control strategy are also outlined. A summary of advanced development status and plans and an overview of system test plans are presented.

  4. Power losses in bent and elongated polymer optical fibers.

    PubMed

    Chen, Yung-Chuan

    2007-07-20

    This study performs experimental and numerical investigations into the power losses induced in bent, elongated polymer optical fibers (POFs). The theoretical analysis is based on a three-dimensional elastic-plastic finite-element model and makes the assumption of a planar waveguide. The finite-element model is used to calculate the deformation of the elongated POFs such that the power loss can be analytically derived. The effect of bending on the power loss is examined by considering seven different bend radii ranging from 10 to 50 mm. The results show that bending and elongation have a significant effect on the power loss in POFs. The contribution of skew rays to the overall power loss in bent, elongated POFs is not obvious at large radii of curvature but becomes more significant as the radius is reduced. PMID:17609702

  5. Prediction of windage power loss in alternators

    NASA Technical Reports Server (NTRS)

    Vrancik, J. E.

    1971-01-01

    Simplified equations and constants, based on laminar and turbulent flow theory between parallel plates, estimate windage loss in rotating electrical machinery. Comparison of calculated results and experimental data for smooth cylindrical rotor and slotted alternator yields 7 percent maximum variation between calculated and experimental data.

  6. Analysis of power loss in Ni-Zn ferrites

    NASA Astrophysics Data System (ADS)

    Kondo, K.; Chiba, T.; Yamada, S.; Otsuki, E.

    2000-05-01

    The power loss (Pcv) was analyzed by combining two methods. The first, Pcv, is divided into hysteresis loss (Ph) and residual loss (Pr) from the frequency dependence of the power loss according to the method of Otsuki et al., and, second, the loss factors are attributed to domain wall motion (Pw) and the rotation magnetization (Prot) by adapting the method proposed by Visser et al. It was found that Pw coincides with Ph in the lower frequency range, but the difference between them becomes significant as frequency goes up. The higher value of Pw, in comparison with Ph in the higher frequency range, can be attributed to the enhancement of loss due to the dynamic motion of the domain wall (Pwd) by raising the frequency. The hysteresis loss dominates Pcv in the frequency range below 500 kHz, while Pwd becomes predominant factor in the higher frequency range more than 500 kHz.

  7. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  8. On loss distributions from installment-repaid loans.

    PubMed

    Crowder, Martin; Hand, David J

    2005-12-01

    The banks have been accumulating huge data bases for many years and are increasingly turning to statistics to provide insight into customer behaviour, among other things. Credit risk is an important issue and certain stochastic models have been developed in recent years to describe and predict loan default. Two of the major models currently used in the industry are considered here, and various ways of extending their application to the case where a loan is repaid in installments are explored. The aspect of interest is the probability distribution of the total loss due to repayment default at some time. Thus, the loss distribution is determined by the distribution of times to default, here regarded as a discrete-time survival distribution. In particular, the probabilities of large losses are to be assessed for insurance purposes. PMID:16328576

  9. Distribution of AC loss in a HTS magnet for SMES with different operating conditions

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Tang, Y.; Ren, L.; Jiao, F.; Song, M.; Cao, K.; Wang, D.; Wang, L.; Dong, H.

    2013-11-01

    The AC loss induced in superconducting tape may affect the performance of a superconducting device applied to power system, such as transformer, cable, motor and even Superconducting Magnetic Energy Storage (SMES). The operating condition of SMES is changeable due to the need of compensation to the active or reactive power according to the demand of a power grid. In this paper, it is investigated that the distribution of AC loss for a storage magnet on different operating conditions, which is based on finite element method (FEM) and measured properties of BSCCO/Ag tapes. This analytical method can be used to optimize the SMES magnet.

  10. Power losses and the efficiency of industrially used gearboxes

    NASA Astrophysics Data System (ADS)

    Čarnogurská, Mária; Příhoda, Miroslav; Širillová, Ľubomíra

    2014-08-01

    This article gives the methodology for stating power losses and the efficiency of a gearbox working in natural cooling using dimensional analysis. The methodology reflects experimental research which investigated the effect of a change in revolutions and loading the gearbox on power losses. At the same time, it describes the conditions under which the proposed method may be applied for industrial, helical bevel geared motors.

  11. Water losses dynamic modelling in water distribution networks

    NASA Astrophysics Data System (ADS)

    Puleo, Valeria; Milici, Barbara

    2015-12-01

    In the last decades, one of the main concerns of the water system managers have been the minimisation of water losses, that frequently reach values of 30% or even 70% of the volume supplying the water distribution network. The economic and social costs associated with water losses in modern water supply systems are rapidly rising to unacceptably high levels. Furthermore, the problem of the water losses assumes more and more importance mainly when periods of water scarcity occur or when not sufficient water supply takes part in areas with fast growth. In the present analysis, a dynamic model was used for estimating real and apparent losses of a real case study. A specific nodal demand model reflecting the user's tank installation and a specific apparent losses module were implemented. The results from the dynamic model were compared with the modelling estimation based on a steady-state approach.

  12. Fundamental rate-loss tradeoff for optical quantum key distribution.

    PubMed

    Takeoka, Masahiro; Guha, Saikat; Wilde, Mark M

    2014-01-01

    Since 1984, various optical quantum key distribution (QKD) protocols have been proposed and examined. In all of them, the rate of secret key generation decays exponentially with distance. A natural and fundamental question is then whether there are yet-to-be discovered optical QKD protocols (without quantum repeaters) that could circumvent this rate-distance tradeoff. This paper provides a major step towards answering this question. Here we show that the secret key agreement capacity of a lossy and noisy optical channel assisted by unlimited two-way public classical communication is limited by an upper bound that is solely a function of the channel loss, regardless of how much optical power the protocol may use. Our result has major implications for understanding the secret key agreement capacity of optical channels-a long-standing open problem in optical quantum information theory-and strongly suggests a real need for quantum repeaters to perform QKD at high rates over long distances. PMID:25341406

  13. Pressure loss modulus correlation for Delta p across uniformly distributed-loss devices

    NASA Technical Reports Server (NTRS)

    Nunz, Gregory J.

    1994-01-01

    A dimensionless group, called a pressure loss modulus (N(sub PL)), is introduced that, in conjunction with an appropriately defined Reynolds number, is of considerable engineering utility in correlating steady-state Delta p vs flow calibration data and subsequently as a predictor, using the same or a different fluid, in uniformly distributed pressure loss devices. It is particularly useful under operation in the transition regime. Applications of this simple bivariate correlation to three diverse devices of particular interest for small liquid rocket engine fluid systems are discussed: large L/D capillary tube restrictors, packed granular catalyst beds, and stacked vortex-loss disk restrictors.

  14. Distributed photovoltaic generation in residential distribution systems: Impacts on power quality and anti-islanding

    NASA Astrophysics Data System (ADS)

    Mitra, Parag

    The past few decades have seen a consistent growth of distributed PV sources. Distributed PV, like other DG sources, can be located at or near load centers and provide benefits which traditional generation may lack. However, distribution systems were not designed to accommodate such power generation sources as these sources might lead to operational as well as power quality issues. A high penetration of distributed PV resources may lead to bi-directional power flow resulting in voltage swells, increased losses and overloading of conductors. Voltage unbalance is a concern in distribution systems and the effect of single-phase residential PV systems on voltage unbalance needs to be explored. Furthermore, the islanding of DGs presents a technical hurdle towards the seamless integration of DG sources with the electricity grid. The work done in this thesis explores two important aspects of grid inte-gration of distributed PV generation, namely, the impact on power quality and anti-islanding. A test distribution system, representing a realistic distribution feeder in Arizona is modeled to study both the aforementioned aspects. The im-pact of distributed PV on voltage profile, voltage unbalance and distribution sys-tem primary losses are studied using CYMDIST. Furthermore, a PSCAD model of the inverter with anti-island controls is developed and the efficacy of the anti-islanding techniques is studied. Based on the simulations, generalized conclusions are drawn and the problems/benefits are elucidated.

  15. Small-signal theory of subterahertz overmoded surface wave oscillator with distributed wall loss

    NASA Astrophysics Data System (ADS)

    Wang, Guangqiang; Wang, Jianguo; Li, Shuang; Wang, Xuefeng

    2015-09-01

    A small-signal theory of the overmoded surface wave oscillator (SWO) with distributed wall loss is presented in this letter. The wall loss considered here includes the surface resistance and surface roughness. The cold and hot characteristics of 0.14 THz SWO are studied by the small-signal theory. Numerical results show that as the increase of wall loss, the working frequency decreases slightly, the rise time and startup time of oscillation increase significantly, and the output power decreases dramatically. Particle-in-cell (PIC) simulation confirms the prediction by the small-signal theory.

  16. Minimizing spacecraft power loss due to single-point failures

    SciTech Connect

    Billerbeck, W.

    1984-08-01

    This paper proposes the application of failure modes and effects analysis (FMEA), in the form of a calculation of the quantitative power loss resulting from single-point failures, as a tool for the design of satellite power systems. This approach differs from most of the previous work done on failure modes and effects analysis, which has been based on calculation of estimated probability of failure within the circuits. A number of failure-resistant communications spacecraft power system topologies and equipment configurations are described. Techniques are presented for analyzing the actual power system performance degradation resulting from various hypothesized single-point failures. Sample calculations are presented for both solar array and battery modes of operation. Design ground rules, circuit topologies, and mechanical configurations for minimizing spacecraft power loss due to single-point failures are described.

  17. Forecasting photovoltaic array power production subject to mismatch losses

    SciTech Connect

    Picault, D.; Raison, B.; Bacha, S.; de la Casa, J.; Aguilera, J.

    2010-07-15

    The development of photovoltaic (PV) energy throughout the world this last decade has brought to light the presence of module mismatch losses in most PV applications. Such power losses, mainly occasioned by partial shading of arrays and differences in PV modules, can be reduced by changing module interconnections of a solar array. This paper presents a novel method to forecast existing PV array production in diverse environmental conditions. In this approach, field measurement data is used to identify module parameters once and for all. The proposed method simulates PV arrays with adaptable module interconnection schemes in order to reduce mismatch losses. The model has been validated by experimental results taken on a 2.2 kW{sub p} plant, with three different interconnection schemes, which show reliable power production forecast precision in both partially shaded and normal operating conditions. Field measurements show interest in using alternative plant configurations in PV systems for decreasing module mismatch losses. (author)

  18. Designing concrete EDS maglev guideways: Power losses in metallic reinforcement

    SciTech Connect

    Beto, D.; Plotkin, D.

    1997-05-01

    Conventional reinforced concrete designs will have to be altered when designing a guideway for a maglev using an electrodynamically suspended (EDS) propulsion system. This type of propulsion system generates large magnetic fields that will develop magnetically induced, circulating eddy currents in any conventional steel reinforcement in close proximity to the magnets. These eddy currents, if large enough, may produce significant power losses that could adversely effect operation of the system. This paper presents a method and explanation for civil engineers to use for estimating the power losses due to the presence of metallic reinforcement. This procedure may be used to help guide future designs in the selection and placement of reinforcing material.

  19. Passive magnetic bearing element with minimal power losses

    DOEpatents

    Post, Richard F.

    1998-01-01

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in U.S. Patent No. 5,495,221 entitled "Dynamically Stable Magnetic Suspension/Bearing System." The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity.

  20. Passive magnetic bearing element with minimal power losses

    DOEpatents

    Post, R.F.

    1998-12-08

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in US Patent No. 5,495,221 entitled ``Dynamically Stable Magnetic Suspension/Bearing System.`` The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity. 8 figs.

  1. Influence of the UV-induced fiber loss on the distributed feedback fiber lasers

    NASA Astrophysics Data System (ADS)

    Fan, Wei; Chen, Bai; Qiao, Qiquan; Chen, Jialing; Lin, Zunqi

    2003-06-01

    It was found that the output power of the distributed feedback fiber lasers would be improved after annealing or left unused for several days after the laser had been fabricated, and the output of the fundamental mode would not increase but be clamped while the ±1 order modes would be predominant with the enhancement of the coupling coefficient during the fabrication. The paper discussed the influence of UV-induced fiber loss on the fiber phase-shifted DFB lasers. Due to the gain saturation and fiber internal loss, which included the temperament loss and permanent loss, there was an optimum coupling coefficient for the DFB fiber lasers that the higher internal fiber loss corresponded to the lower optimum values of coupling coefficient.

  2. Electric power distribution and load transfer system

    NASA Technical Reports Server (NTRS)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1989-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  3. High-Frequency ac Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.; Mildice, James

    1987-01-01

    Loads managed automatically under cycle-by-cycle control. 440-V rms, 20-kHz ac power system developed. System flexible, versatile, and "transparent" to user equipment, while maintaining high efficiency and low weight. Electrical source, from dc to 2,200-Hz ac converted to 440-V rms, 20-kHz, single-phase ac. Power distributed through low-inductance cables. Output power either dc or variable ac. Energy transferred per cycle reduced by factor of 50. Number of parts reduced by factor of about 5 and power loss reduced by two-thirds. Factors result in increased reliability and reduced costs. Used in any power-distribution system requiring high efficiency, high reliability, low weight, and flexibility to handle variety of sources and loads.

  4. Marginal Power Loss Extraction Method for Future High Output Power Density Converter

    NASA Astrophysics Data System (ADS)

    Takao, Kazuto; Adachi, Kazuhiro; Hayashi, Yusuke; Ohashi, Hiromichi

    Novel exact MOSFET switching loss analysis and formulation methods have been proposed for designing high output power density converters. To analyze influences of circuit stray parameters on MOSFET switching loss with experiments, a parameter adjustable circuit board has been fabricated. The circuit board has a function to vary circuit stray inductance and capacitance values like a circuit simulator. Correlations between MOSFET switching loss energies and circuit stray parameters are successfully analyzed with the circuit board. Based on the analysis results, switching loss energies are formulated with empirical equations to establish a exact power loss calculation tool for the converter design. Switching loss energies caused by semiconductor device parameters are modeled by a capacitance charge/discharge model. The procedure to formulate the switching loss energies with empirical equations is presented. Switching loss energies calculated with empirical equations are verified with measurements, and high accuracy of more than 95% has been achieved.

  5. Study of the longitudinal distribution of power generated in a random distributed feedback Raman fibre laser with unidirectional pumping

    SciTech Connect

    Churkin, D V; El-Taher, A E; Vatnik, I D; Babin, Sergei A

    2012-09-30

    The longitudinal distribution of the Stokes-component power in a Raman fibre laser with a random distributed feedback and unidirectional pumping is measured. The fibre parameters (linear loss and Rayleigh backscattering coefficient) are calculated based on the distributions obtained. A numerical model is developed to describe the lasing power distribution. The simulation results are in good agreement with the experimental data. (optical fibres, lasers and amplifiers. properties and applications)

  6. Union Power, Cost of Job Loss, and Workers' Effort.

    ERIC Educational Resources Information Center

    Green, Francis; McIntosh, Steven

    1998-01-01

    Data from 2,061 British companies in the Workplace Industrial Relations Survey supported the hypothesis that powerful unions reduce the external threat of job loss and therefore the pace of work in unionized firms is less responsive to such threats. (SK)

  7. Power loss for high-voltage solar-cell arrays

    NASA Technical Reports Server (NTRS)

    Parker, L. W.

    1979-01-01

    Electric field particle collection and power loss are calculated in program written in FORTRAN IV for use on UNIVAC 1100/40 computer. Program incorporates positive and negative and negative charge flows and balance between positive and negative flows is performed by iteration.

  8. Distributed control of reactive power flow in a radial distribution circuit with high photovoltaic penetration

    SciTech Connect

    Chertkov, Michael; Turitsyn, Konstantin; Backhaus, Scott; Sule, Petr

    2009-01-01

    We show how distributed control of reactive power can serve to regulate voltage and minimize resistive losses in a distribution circuit that includes a significant level of photovoltaic (PV) generation. To demonstrate the technique, we consider a radial distribution circuit with a single branch consisting of sequentially-arranged residential-scale loads that consume both real and reactive power. In parallel, some loads also have PV generation capability. We postulate that the inverters associated with each PV system are also capable of limited reactive power generation or consumption, and we seek to find the optimal dispatch of each inverter's reactive power to both maintain the voltage within an acceptable range and minimize the resistive losses over the entire circuit. We assume the complex impedance of the distribution circuit links and the instantaneous load and PV generation at each load are known. We compare the results of the optimal dispatch with a suboptimal local scheme that does not require any communication. On our model distribution circuit, we illustrate the feasibility of high levels of PV penetration and a significant (20% or higher) reduction in losses.

  9. Computer Power: Part 1: Distribution of Power (and Communications).

    ERIC Educational Resources Information Center

    Price, Bennett J.

    1988-01-01

    Discussion of the distribution of power to personal computers and computer terminals addresses options such as extension cords, perimeter raceways, and interior raceways. Sidebars explain: (1) the National Electrical Code; (2) volts, amps, and watts; (3) transformers, circuit breakers, and circuits; and (4) power vs. data wiring. (MES)

  10. Space Solar Power Management and Distribution (PMAD)

    NASA Technical Reports Server (NTRS)

    Lynch, Thomas H.

    2000-01-01

    This paper presents, in viewgraph form, SSP PMAD (Space Solar Power Management and Distribution). The topics include: 1) Architecture; 2) Backside Thermal View; 3) Solar Array Interface; 4) Transformer design and risks; 5) Twelve phase rectifier; 6) Antenna (80V) Converters; 7) Distribution Cables; 8) Weight Analysis; and 9) PMAD Summary.

  11. Healthcare Assistants: distributional losses as a consequence of NHS modernisation?

    PubMed Central

    Clark, Ian; Thompson, Amanda

    2015-01-01

    This paper examines the labour process of Healthcare Assistants (HCAs) at a National Health Service (NHS) hospital trust (TUH) in the context of the NHS modernisation agenda. It determines whether application of the modernisation agenda is formalised at TUH and considers how HCAs are affected. The paper is based upon 60 interviews with HCAs, structured questionnaires completed by all interview respondents, observation of HCAs and interviews with non‐clinical managers. The findings show that elements of the modernisation agenda are informally implemented at TUH to the detriment of HCAs. HCAs experience distributional losses in the form of intensification as nurses deflect duties to HCAs and insulate themselves from adverse effects. HCAs resist, using selective absence when pressures mount. They ameliorate losses by re‐internalising their work as a job with caring elements not a genuine caring role. They rationalise their altered behaviour towards patients by blaming the regime's treatment of them as a subordinated group. PMID:27570359

  12. Cathode power distribution system and method of using the same for power distribution

    DOEpatents

    Williamson, Mark A; Wiedmeyer, Stanley G; Koehl, Eugene R; Bailey, James L; Willit, James L; Barnes, Laurel A; Blaskovitz, Robert J

    2014-11-11

    Embodiments include a cathode power distribution system and/or method of using the same for power distribution. The cathode power distribution system includes a plurality of cathode assemblies. Each cathode assembly of the plurality of cathode assemblies includes a plurality of cathode rods. The system also includes a plurality of bus bars configured to distribute current to each of the plurality of cathode assemblies. The plurality of bus bars include a first bus bar configured to distribute the current to first ends of the plurality of cathode assemblies and a second bus bar configured to distribute the current to second ends of the plurality of cathode assemblies.

  13. W-band TE{sub 01} gyrotron backward-wave oscillator with distributed loss

    SciTech Connect

    Chang, T. H.; Yu, C. F.; Hung, C. L.; Yeh, Y. S.; Hsiao, M. C.; Shin, Y. Y.

    2008-07-15

    Distributed wall loss is proposed to enhance the stability and tunability of a W-band TE{sub 01} gyrotron backward-wave oscillator (gyro-BWO). Simulation results reveal that loss effectively suppresses the unwanted transverse modes as well as the high-order axial modes (HOAMs) without degrading the performance of a gyro-BWO that operates at the fundamental axial mode. Linear and nonlinear codes are used to calculate the interaction properties. The effects of the distributed loss on the starting currents of all of the modes of interest are discussed in depth. The interacting structure is optimized for stability. The calculated peak output power is 102 kW, corresponding to an efficiency of 20%. The 3 dB tuning bandwidth is 1.8 GHz, centered at 94.0 GHz when using 5 A and 100 kV electron beam.

  14. Effect of the electron energy distribution on total energy loss with argon in inductively coupled plasmas

    SciTech Connect

    Kim, June Young; Kim, Young-Cheol; Kim, Yu-Sin; Chung, Chin-Wook

    2015-01-15

    The total energy lost per electron-ion pair lost ε{sub T} is investigated with the electron energy distribution function (EEDF). The EEDFs are measured at various argon powers in RF inductively coupled plasma, and the EEDFs show a depleted distribution (a discontinuity occurring at the minimum argon excitation threshold energy level) with the bulk temperature and the tail temperature. The total energy loss per electron-ion pair lost ε{sub T} is calculated from a power balance model with the Maxwellian EEDFs and the depleted EEDFs and then compared with the measured ε{sub T} from the floating probe. It is concluded that the small population of the depleted high energy electrons dramatically increases the collisional energy loss, and the calculated ε{sub T} from the depleted EEDFs has a value that is similar to the measured ε{sub T}.

  15. Effect of the electron energy distribution on total energy loss with argon in inductively coupled plasmas

    NASA Astrophysics Data System (ADS)

    Kim, June Young; Kim, Young-Cheol; Kim, Yu-Sin; Chung, Chin-Wook

    2015-01-01

    The total energy lost per electron-ion pair lost ɛT is investigated with the electron energy distribution function (EEDF). The EEDFs are measured at various argon powers in RF inductively coupled plasma, and the EEDFs show a depleted distribution (a discontinuity occurring at the minimum argon excitation threshold energy level) with the bulk temperature and the tail temperature. The total energy loss per electron-ion pair lost ɛT is calculated from a power balance model with the Maxwellian EEDFs and the depleted EEDFs and then compared with the measured ɛT from the floating probe. It is concluded that the small population of the depleted high energy electrons dramatically increases the collisional energy loss, and the calculated ɛT from the depleted EEDFs has a value that is similar to the measured ɛT.

  16. Intelligent Systems for Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Button, Robert M.

    2002-01-01

    The motivation behind an advanced technology program to develop intelligent power management and distribution (PMAD) systems is described. The program concentrates on developing digital control and distributed processing algorithms for PMAD components and systems to improve their size, weight, efficiency, and reliability. Specific areas of research in developing intelligent DC-DC converters and distributed switchgear are described. Results from recent development efforts are presented along with expected future benefits to the overall PMAD system performance.

  17. Stable harmonic multiplying gyrotron traveling-wave amplifier with distributed wall losses and attenuating severs

    SciTech Connect

    Yeh, Y. S.; Cheng, J. H.; Chen, L. K.; Hung, C. W.; Lo, C. Y.; Liao, C. W.

    2008-02-15

    Harmonic multiplying gyrotron traveling-wave amplifiers (gyro-TWTs) provide magnetic field reduction and frequency multiplication. However, spurious oscillations may reduce the amplification of the gyro-TWT. Most distributed-loss structures are stabilized in gyro-TWTs that operate at low beam currents. Attenuating severs are added to the interaction circuit of a distributed-loss gyro-TWT to prevent high beam currents that result in mode competition. This study proposes a Ka-band harmonic multiplying gyro-TWT, using distributed wall losses and attenuating severs, to improve the stability of the amplification and the performance of the amplifier. Simulation results reveal that the absolute instabilities are effectively suppressed by wall losses of the lossy and severed sections, especially in the low-k{sub z} and high-order modes. Meanwhile, the severed section, dividing an interaction circuit into several short sections, reduces the effective interaction lengths of the absolute instabilities. The stable harmonic multiplying gyro-TWT is predicted to yield a peak output power of 230 kW at 33.65 GHz with an efficiency of 30%, a saturated gain of 40 dB, and a 3 dB bandwidth of 0.8 GHz for a 60 kV, 13 A electron beam with an axial velocity spread of {delta}v{sub z}/v{sub z}=8%. The power/gain scaling and phase relation between the drive and the output waves are elucidated.

  18. Helicopter optimal descent and landing after power loss

    NASA Technical Reports Server (NTRS)

    Johnson, W.

    1977-01-01

    An optimal control solution is obtained for the descent and landing of a helicopter after the loss of power in level flight. The model considers the helicopter vertical velocity, horizontal velocity, and rotor speed; and it includes representations of ground effect, rotor inflow time lag, pilot reaction time, rotor stall, and the induced velocity curve in the vortex ring state. The control (rotor thrust magnitude and direction) required to minimize the vertical and horizontal velocity at contact with the ground is obtained using nonlinear optimal control theory. It is found that the optimal descent after power loss in hover is a purely vertical flight path. Good correlation, even quantitatively, is found between the calculations and (non-optimal) flight test results.

  19. Grid-connected distributed solar power systems

    NASA Astrophysics Data System (ADS)

    Moyle, R.; Chernoff, H.; Schweizer, T.

    This paper discusses some important, though often ignored, technical and economic issues of distributed solar power systems: protection of the utility system and nonsolar customers requires suitable interfaced equipment. Purchase criteria must mirror reality; most analyses use life-cycle costing with low discount rates - most buyers use short payback periods. Distributing, installing, and marketing small, distributed solar systems is more costly than most analyses estimate. Results show that certain local conditions and uncommon purchase considerations can combine to make small, distributed solar power attractive, but lower interconnect costs (per kW), lower marketing and product distribution costs, and more favorable purchase criteria make large, centralized solar energy more attractive. Specifically, the value of dispersed solar systems to investors and utilities can be higher than $2000/kw. However, typical residential owners place a value of well under $1000 on the installed system.

  20. Vibration Monitoring of Power Distribution Poles

    SciTech Connect

    Clark Scott; Gail Heath; John Svoboda

    2006-04-01

    Some of the most visible and least monitored elements of our national security infrastructure are the poles and towers used for the distribution of our nation’s electrical power. Issues surrounding these elements within the United States include safety such as unauthorized climbing and access, vandalism such as nut/bolt removal or destructive small arms fire, and major vandalism such as the downing of power poles and towers by the cutting of the poles with a chainsaw or torches. The Idaho National Laboratory (INL) has an ongoing research program working to develop inexpensive and sensitive sensor platforms for the monitoring and characterization of damage to the power distribution infrastructure. This presentation covers the results from the instrumentation of a variety of power poles and wires with geophone assemblies and the recording of vibration data when power poles were subjected to a variety of stimuli. Initial results indicate that, for the majority of attacks against power poles, the resulting signal can be seen not only on the targeted pole but on sensors several poles away in the distribution network and a distributed sensor system can be used to monitor remote and critical structures.

  1. Intensity distribution analysis of cathodoluminescence using the energy loss distribution of electrons.

    PubMed

    Fukuta, Masahiro; Inami, Wataru; Ono, Atsushi; Kawata, Yoshimasa

    2016-01-01

    We present an intensity distribution analysis of cathodoluminescence (CL) excited with a focused electron beam in a luminescent thin film. The energy loss distribution is applied to the developed analysis method in order to determine the arrangement of the dipole locations along the path of the electron traveling in the film. Propagating light emitted from each dipole is analyzed with the finite-difference time-domain (FDTD) method. CL distribution near the film surface is evaluated as a nanometric light source. It is found that a light source with 30 nm widths is generated in the film by the focused electron beam. We also discuss the accuracy of the developed analysis method by comparison with experimental results. The analysis results are brought into good agreement with the experimental results by introducing the energy loss distribution. PMID:26550930

  2. Lower hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

    NASA Astrophysics Data System (ADS)

    Faust, I. C.; Brunner, D.; LaBombard, B.; Parker, R. R.; Terry, J. L.; Whyte, D. G.; Baek, S. G.; Edlund, E.; Hubbard, A. E.; Hughes, J. W.; Kuang, A. Q.; Reinke, M. L.; Shiraiwa, S.; Wallace, G. M.; Walk, J. R.

    2016-05-01

    For the first time, the power deposition of lower hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal, and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt ( t < τ E ) response of the scrape-off-layer (SOL) plasma to Lower Hybrid Radiofrequency (LHRF) power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be a key for the LHRF edge power deposition physics. These observations support the existence of a loss mechanism near the edge for LHRF at high density ( n e > 1.0 × 10 20 (m-3)). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. These characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivate the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch.

  3. Power distribution studies for CMS forward tracker

    SciTech Connect

    Todri, A.; Turqueti, M.; Rivera, R.; Kwan, S.

    2009-01-01

    The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory is carrying out R&D investigations for the upgrade of the power distribution system of the Compact Muon Solenoid (CMS) Pixel Tracker at the Large Hadron Collider (LHC). Among the goals of this effort is that of analyzing the feasibility of alternative powering schemes for the forward tracker, including DC to DC voltage conversion techniques using commercially available and custom switching regulator circuits. Tests of these approaches are performed using the PSI46 pixel readout chip currently in use at the CMS Tracker. Performance measures of the detector electronics will include pixel noise and threshold dispersion results. Issues related to susceptibility to switching noise will be studied and presented. In this paper, we describe the current power distribution network of the CMS Tracker, study the implications of the proposed upgrade with DC-DC converters powering scheme and perform noise susceptibility analysis.

  4. Inverter design for high frequency power distribution

    NASA Technical Reports Server (NTRS)

    King, R. J.

    1985-01-01

    A class of simple resonantly commutated inverters are investigated for use in a high power (100 KW - 1000 KW) high frequency (10 KHz - 20 KHz) AC power distribution system. The Mapham inverter is found to provide a unique combination of large thyristor turn-off angle and good utilization factor, much better than an alternate 'current-fed' inverter. The effects of loading the Mapham inverter entirely with rectifier loads are investigated by simulation and with an experimental 3 KW 20 KHz inverter. This inverter is found to be well suited to a power system with heavy rectifier loading.

  5. Reflectance loss of prospective solar concentrator mirrors in erosive environments. The Crosbyton Solar Power Project

    SciTech Connect

    Bethea, R.M.; Barringer, M.T.; Chin, S.; Collier, E.G.; Cooper, A.M.; Reichert, J.D. Jr.; Williams, P.F.

    1986-01-01

    The problem addressed in this phase of the Crosbyton Solar Power Project was that of the effect of weathering of solar concentrator mirrors proposed for use in the fixed-mirror, distributed-focus (solar bowl) system with particular emphasis on erosion due to exposure during dust storms. The specific objectives of this research were to evaluate the mirrors with respect to initial reflectance, loss of reflectance due to dust storms and other outdoor exposure phenomena, and dimensional stability; and to develop a rapid technique for the simulation of dust storms so that a model for such reflectance loss as a function of exposure could be developed.

  6. Method for Loss Minimum Re-configuration Problem of Distribution System by Tabu Search

    NASA Astrophysics Data System (ADS)

    Mishima, Yuji; Nara, Koichi; Satoh, Taiji; Ito, Takamitsu; Kaneda, Hirotoshi

    This paper proposes a loss minimum reconfiguration method by Tabu Search for open loop radial distribution system with distributed generators. The problem is to find the optimal normal open sectionalizing switch positions which minimize the total distribution line losses subjected to the line/transformer capacity constraints and voltage constraint. Generally, the problem is mathematically formulated as a complex combinatorial optimization problem or mixed integer programming problem, and is solved by using mathematical programming method, heuristic algorithm, intelligent method, etc. However, satisfactory algorithm for power companies has not yet been attained both in computational burden and solution accuracy. Thus, in this paper, the authors propose a method to solve the above problem by using Tabu Search (TS) method. Reverse power flow caused by distributed generators can be included in the solution algorithm. TS is one of meta-heuristic algorithms, and sometimes evaluated to be better compared with Genetic Algorithm (GA) or Simulated Annealing (SA) from viewpoints of both computational speed and solution accuracy. In order to evaluate the validity and efficiency of the algorithm, several numerical examples are shown in this paper.

  7. Power quality monitoring of a distribution system

    SciTech Connect

    Barker, P.P.; Burke, J.T.; Mancao, R.T.; Short, T.A.; Warren, C.A. ); Burns, C.W.; Siewierski, J.J. )

    1994-04-01

    The Niagara Mohawk Power Corporation (NMPC) Research and Development Department sponsored a major power quality study of two distribution feeders in the Buffalo, New York region. All levels of these systems, from the substation bus to the customer service entrance, were instrumented with monitoring equipment. A variety of measurements, encompassing both transient and steady state system behavior, were performed. The use of multiple monitoring locations allowed NMPC to assess the origins and scope of various disturbances. The study generated a database which can serve as a guide for assessing relative power quality on the NMPC system. The study also formulated suggestions on areas which the industry (both the power industry and consumer products industry) might address in the future on the effect of standard utility operation towards consumer appliances.

  8. Power Management and Distribution System Developed for Thermionic Power Converters

    NASA Technical Reports Server (NTRS)

    Baez, Anastacio N.

    1998-01-01

    A spacecraft solar, bimodal system combines propulsion and power generation into a single integrated system. An Integrated Solar Upper Stage (ISUS) provides orbital transfer capabilities, power generation for payloads, and onboard propulsion to the spacecraft. A key benefit of a bimodal system is a greater payload-to-spacecraft mass ratio resulting in lower launch vehicle requirements. Scaling down to smaller launch vehicles increases space access by reducing overall mission cost. NASA has joined efforts with the Air Force Phillips Laboratory to develop enabling technologies for such a system. The NASA/Air Force bimodal concept uses solar concentrators to focus energy into an integrated power plant. This power plant consists of a graphite core that stores thermal energy within a cavity. An array of thermionic converters encircles the graphite cavity and provides electrical energy conversion functions. During the power generation phase of the bimodal system, the thermionic converters are exposed to the heated cavity and convert the thermal energy to electricity. Near-term efforts of the ISUS bimodal program are focused on a ground demonstration of key technologies in order to proceed to a full space flight test. Thermionic power generation is one key technology of the bimodal concept. Thermionic power converters impose unique operating requirements upon a power management and distribution (PMAD) system design. Single thermionic converters supply large currents at very low voltages. Operating voltages can vary over a range of up to 3 to 1 as a function of operating temperature. Most spacecraft loads require regulated 28-volts direct-current (Vdc) power. A combination of series-connected converters and powerprocessing boosters is required to deliver power to the spacecraft's payloads at this level.

  9. Uncertainty evaluation in BEACON power distribution monitoring

    SciTech Connect

    Morita, T.; Goldstein, N.P. )

    1989-11-01

    BEACON is an advanced operational core support package that has a three-dimensional nodal code as its cornerstone. The three-dimensional calculation includes all necessary pressurized water reactor feedback effects. The generation of the measured power distribution from the core instrumentation is one of the primary functions of the core-monitoring software. The purpose of this paper is to discuss evaluation of the uncertainty in the measured assembly power from the BEACON system. The study covers not only the normal operating conditions, but off-normal situations to demonstrate BEACON's applicability for that condition.

  10. AC loss in high-temperature superconducting conductors, cables and windings for power devices

    NASA Astrophysics Data System (ADS)

    Oomen, M. P.; Rieger, J.; Hussennether, V.; Leghissa, M.

    2004-05-01

    High-temperature superconducting (HTS) transformers and reactor coils promise decreased weight and volume and higher efficiency. A critical design parameter for such devices is the AC loss in the conductor. The state of the art for AC-loss reduction in HTS power devices is described, starting from the loss in the single HTS tape. Improved tape manufacturing techniques have led to a significant decrease in the magnetization loss. Transport-current loss is decreased by choosing the right operating current and temperature. The role of tape dimensions, filament twist and resistive matrix is discussed and a comparison is made between state-of-the-art BSCCO and YBCO tapes. In transformer and reactor coils the AC loss in the tape is influenced by adjacent tapes in the coil, fields from other coils, overcurrents and higher harmonics. These factors are accounted for by a new AC-loss prediction model. Field components perpendicular to the tape are minimized by optimizing the coil design and by flux guidance pieces. High-current windings are made of Roebel conductors with transposed tapes. The model iteratively finds the temperature distribution in the winding and predicts the onset of thermal instability. We have fabricated and tested several AC windings and used them to validate the model. Now we can confidently use the model as an engineering tool for designing HTS windings and for determining the necessary tape properties.

  11. Relativity, nonextensivity, and extended power law distributions.

    PubMed

    Silva, R; Lima, J A S

    2005-11-01

    A proof of the relativistic theorem by including nonextensive effects is given. As it happens in the nonrelativistic limit, the molecular chaos hypothesis advanced by Boltzmann does not remain valid, and the second law of thermodynamics combined with a duality transformation implies that the parameter lies on the interval [0,2]. It is also proven that the collisional equilibrium states (null entropy source term) are described by the relativistic power law extension of the exponential Juttner distribution which reduces, in the nonrelativistic domain, to the Tsallis power law function. As a simple illustration of the basic approach, we derive the relativistic nonextensive equilibrium distribution for a dilute charged gas under the action of an electromagnetic field . Such results reduce to the standard ones in the extensive limit, thereby showing that the nonextensive entropic framework can be harmonized with the space-time ideas contained in the special relativity theory. PMID:16383791

  12. Electrical power systems for distributed generation

    SciTech Connect

    Robertson, T.A.; Huval, S.J.

    1996-12-31

    {open_quotes}Distributed Generation{close_quotes} has become the {open_quotes}buzz{close_quotes} word of an electric utility industry facing deregulation. Many industrial facilities utilize equipment in distributed installations to serve the needs of a thermal host through the capture of exhaust energy in a heat recovery steam generator. The electrical power generated is then sold as a {open_quotes}side benefit{close_quotes} to the cost-effective supply of high quality thermal energy. Distributed generation is desirable for many different reasons, each with unique characteristics of the product. Many years of experience in the distributed generation market has helped Stewart & Stevenson to define a range of product features that are crucial to most any application. The following paper will highlight a few of these applications. The paper will also examine the range of products currently available and in development. Finally, we will survey the additional services offered by Stewart & Stevenson to meet the needs of a rapidly changing power generation industry.

  13. Power loss measurement of implantable wireless power transfer components using a Peltier device balance calorimeter

    NASA Astrophysics Data System (ADS)

    Leung, Ho Yan; Budgett, David M.; Taberner, Andrew; Hu, Patrick

    2014-09-01

    Determining heat losses in power transfer components operating at high frequencies for implantable inductive power transfer systems is important for assessing whether the heat dissipated by the component is acceptable for implantation and medical use. However, this is a challenge at high frequencies and voltages due to limitations in electronic instrumentation. Calorimetric methods of power measurement are immune to the effects of high frequencies and voltages; hence, the measurement is independent of the electrical characteristics of the system. Calorimeters have been widely used to measure the losses of high power electrical components (>50 W), however it is more difficult to perform on low power components. This paper presents a novel power measurement method for components dissipating anywhere between 0.2 W and 1 W of power based on a heat balance calorimeter that uses a Peltier device as a balance sensor. The proposed balance calorimeter has a single test accuracy of ±0.042 W. The experimental results revealed that there was up to 35% difference between the power measurements obtained with electrical methods and the proposed calorimeter.

  14. Optimal multi-stage planning of power distribution systems

    SciTech Connect

    Gonen, T.; Ramirez-Rosado, I.J.

    1987-04-01

    This paper presents a completely-dynamic mixed-integer model to solve the optimal sizing, timing, and location of distribution substation and feeder expansion problems simultaneously. The objective function of the model represents the present worth of costs of investment, energy, and demand losses of the system which takes place throughout the planning time horizon. It is minimized subject to the Kirchhoff's current law, power capacity limits, and logical constraints by using a standard mathematical programming system. The developed model allows to include the explicit constraints of radiality and voltage drop in its formulation.

  15. 26 CFR 1.731-1 - Extent of recognition of gain or loss on distribution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Extent of recognition of gain or loss on distribution. 1.731-1 Section 1.731-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... recognition of gain or loss on distribution. (a) Recognition of gain or loss to partner—(1) Recognition...

  16. Numerical study on AC loss characteristics of superconducting power transmission cables comprising coated conductors with magnetic substrates

    NASA Astrophysics Data System (ADS)

    Amemiya, N.; Nakahata, M.

    2007-10-01

    Electromagnetic field analyses were made for mono-layer conductors comprising coated conductors for superconducting power transmission cables in order to evaluate their AC loss characteristics. We focused on the magnetic properties of the substrates of coated conductors. The current distribution in each coated conductor and the magnetic flux profile around each coated conductor were visualized. The influence of relative permeability and the space between coated conductors on the AC loss characteristics of mono-layer conductors were studied based on the visualized current and magnetic flux distributions. The influence of a saturated magnetic property on a calculated AC loss was also discussed.

  17. LH Power Losses In Front of the JET Launcher

    SciTech Connect

    Jacquet, P.; Arnoux, G.; Kirov, K.; Mailloux, J.; Mayoral, M.-L.; Ongena, J.

    2009-11-26

    In recent JET experiments, Lower Hybrid (LH) power losses in the Scrape-Off Layer (SOL) were characterized using infra-red (IR) thermography. Hot spots were observed on objects intercepting the field lines passing in front of the LH launcher, i.e. on poloidal limiters and on dumplates located at the top of the tokamak; their locations being in good agreement with magnetic field line tracing using the EFIT equilibrium code. The dumplate temperature was monitored while scanning the launcher position so that the radial distance between field lines intercepting the hot spots and the launcher was increased up to 3.5 cm. The dissipation layer in front of the launcher was estimated to be at least 3.5 cm wide, in agreement with recent measurements on Tore-Supra, but not with simple models that predict a dissipation layer in the mm range.

  18. Reduction in overvoltages and dynamic power losses in power switches of multilevel voltage inverters

    NASA Astrophysics Data System (ADS)

    Voronin, P. A.; Voronin, I. P.; Panfilov, D. I.; Rozhkov, D. V.

    2014-12-01

    A number of the circuit and design decisions that provide a reduction in overvoltage and dynamic power losses in power switches of multilevel voltage inverters with clamping diodes is considered. It is shown that the integral or unpackaged version is the most effective method for a reduction in the stray inductance in the multilevel circuit, which is the general cause for occurrence of dynamic overvoltage. To reduce dynamic losses of power, a method for resonant commutation on fronts, which provides commutation of switches in the multilevel circuit at zero voltage (SZV) and zero current (SZC), is proposed. The resonant switching method as applied to the multilevel circuit simultaneously solves a problem of dynamic overvoltage by means of limitation for the rate of voltage rise in the SZV mode or the mode of preliminary fault of energy stored in the inductance of the switching circuit in the SZC mode.

  19. Analysis of Power Converter Losses in Vector Control System of a Self-Excited Induction Generator

    NASA Astrophysics Data System (ADS)

    Bašić, Mateo; Vukadinović, Dinko; Polić, Miljenko

    2014-03-01

    This paper provides analysis of losses in the hysteresis-driven three-phase power converter with IGBTs and free-wheeling diodes. The converter under consideration is part of the self-excited induction generator (SEIG) vector control system. For the analysis, the SEIG vector control system is used in which the induction generator iron losses are taken into account. The power converter losses are determined by using a suitable loss estimation algorithm reported in literature. The chosen algorithm allows the power converter losses to be determined both by type (switching/conduction losses) and by converter component (IGBT/diode losses). The overall power converter losses are determined over wide ranges of rotor speed, dc-link voltage and load resistance, and subsequently used for offline correction of the overall control system's losses (efficiency) obtained through control system simulations with an ideal power converter. The control system's efficiency values obtained after the correction are compared with the measured values.

  20. Microwave Driven Actuators Power Allocation and Distribution

    NASA Technical Reports Server (NTRS)

    Forbes, Timothy; Song, Kyo D.

    2000-01-01

    Design, fabrication and test of a power allocation and distribution (PAD) network for microwave driven actuators is presented in this paper. Development of a circuit that would collect power from a rectenna array amplify and distribute the power to actuators was designed and fabricated for space application in an actuator array driven by a microwave. A P-SPICE model was constructed initially for data reduction purposes, and was followed by a working real-world model. A voltage up - converter (VUC) is used to amplify the voltage from the individual rectenna. The testing yielded a 26:1 voltage amplification ratio with input voltage at 9 volts and a measured output voltage 230VDC. Future work includes the miniaturization of the circuitry, the use of microwave remote control, and voltage amplification technology for each voltage source. The objective of this work is to develop a model system that will collect DC voltage from an array of rectenna and propagate the voltage to an array of actuators.

  1. RTDS-Based Design and Simulation of Distributed P-Q Power Resources in Smart Grid

    NASA Astrophysics Data System (ADS)

    Taylor, Zachariah David

    In this Thesis, we propose to utilize a battery system together with its power electronics interfaces and bidirectional charger as a distributed P-Q resource in power distribution networks. First, we present an optimization-based approach to operate such distributed P-Q resources based on the characteristics of the battery and charger system as well as the features and needs of the power distribution network. Then, we use the RTDS Simulator, which is an industry-standard simulation tool of power systems, to develop two RTDS-based design approaches. The first design is based on an ideal four-quadrant distributed P-Q power resource. The second design is based on a detailed four-quadrant distributed P-Q power resource that is developed using power electronics components. The hardware and power electronics circuitry as well as the control units are explained for the second design. After that, given the two-RTDS designs, we conducted extensive RTDS simulations to assess the performance of the designed distributed P-Q Power Resource in an IEEE 13 bus test system. We observed that the proposed design can noticeably improve the operational performance of the power distribution grid in at least four key aspects: reducing power loss, active power peak load shaving at substation, reactive power peak load shaving at substation, and voltage regulation. We examine these performance measures across three design cases: Case 1: There is no P-Q Power Resource available on the power distribution network. Case 2: The installed P-Q Power Resource only supports active power, i.e., it only utilizes its battery component. Case 3: The installed P-Q Power Resource supports both active and reactive power, i.e., it utilizes both its battery component and its power electronics charger component. In the end, we present insightful interpretations on the simulation results and suggest some future works.

  2. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2007-01-01

    Seal leakage decreases with increasing surface speed due to reduced clearances from disk centrifugal growth. Annular and labyrinth seal leakage are 2-3 times greater than brush and finger seal leakage. Seal leakage rates increase with increasing temperature because of seal clearance growth due to different coefficients of thermal expansion between the seal and test disk. Seal power loss is not strongly affected by inlet temperature. Seal power loss increases with increasing surface speed, seal pressure differential, mass flow rate or flow factor, and radial clearance. The brush and finger seals had nearly the same power loss. Annular and labyrinth seal power loss were higher than finger or brush seal power loss. The brush seal power loss was the lowest and 15-30% lower than annular and labyrinth seal power loss.

  3. Network integration of distributed power generation

    NASA Astrophysics Data System (ADS)

    Dondi, Peter; Bayoumi, Deia; Haederli, Christoph; Julian, Danny; Suter, Marco

    The world-wide move to deregulation of the electricity and other energy markets, concerns about the environment, and advances in renewable and high efficiency technologies has led to major emphasis being placed on the use of small power generation units in a variety of forms. The paper reviews the position of distributed generation (DG, as these small units are called in comparison with central power plants) with respect to the installation and interconnection of such units with the classical grid infrastructure. In particular, the status of technical standards both in Europe and USA, possible ways to improve the interconnection situation, and also the need for decisions that provide a satisfactory position for the network operator (who remains responsible for the grid, its operation, maintenance and investment plans) are addressed.

  4. Interaction of lightning with power distribution lines

    NASA Astrophysics Data System (ADS)

    Mata, Carlos Tomas

    Triggered-lightning experiments were conducted in 1996, 1999, and 2000 to study the responses of overhead power distribution lines to lightning at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The lightning was artificially initiated (triggered) from natural thunderclouds using the rocket-and-wire technique, and its current was directed to a phase conductor at midspan or at a pole near the center of the line. Experimental results and associated EMTP modeling are presented in this dissertation for the following line configurations: (1)a two-conductor, 740-m overhead distribution line with 2 arrester stations in 1996; (2)a four- conductor, 245-m overhead distribution line with 2 arrester stations in 1999; and (3)a four-conductor, 829-m overhead distribution line with 6 arrester stations in 2000. The three-phase lines tested in 1999 and 2000 were standard designs of a major Florida power company. Lightning peak currents injected into the lines ranged from 7 to 57 kA. Voltages and currents were measured at various locations along the line. Video and photographic cameras were used to image lightning channels and detect line flashovers. The significant results of the research are (1)flashovers between conductors were observed, both accompanied and not accompanied by arrester failures, (2)an arrester failed on seven of eight direct lightning strikes to the line in 2000, (3)arcing between conductors may prevent failures of arresters connected to the struck phase, (4)the bulk of the lightning current flows from the struck phase to neutral through the arresters closest to the strike point, (5)the withstand energy of the arresters can be exceeded due to the contribution from multiple strokes and/or relatively low-level, long-lasting current components, (6)the distribution of charge transferred to ground among multiple neutral grounds, which is determined by low-frequency, low-current grounding resistances is different from the

  5. Lower Hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

    NASA Astrophysics Data System (ADS)

    Faust, I. C.

    2015-11-01

    For the first time, the power deposition of Lower Hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt (t <τE) response of the scrape-off-layer (SOL) plasma to LHRF power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be key for the LHRF edge power deposition physics. These observations support the existence a loss mechanism near the edge for LHRF at high density (ne > 1 . 0 .1020 [m-3]). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. These characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivates the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch. This work was performed on the Alcator C-Mod tokamak, a DoE Office of Science user facility, and is supported by USDoE award DE-FC02-99ER54512.

  6. High power distributed x-ray source

    NASA Astrophysics Data System (ADS)

    Frutschy, Kris; Neculaes, Bogdan; Inzinna, Lou; Caiafa, Antonio; Reynolds, Joe; Zou, Yun; Zhang, Xi; Gunturi, Satish; Cao, Yang; Waters, Bill; Wagner, Dave; De Man, Bruno; McDevitt, Dan; Roffers, Rick; Lounsberry, Brian; Pelc, Norbert J.

    2010-04-01

    This paper summarizes the development of a distributed x-ray source with up to 60kW demonstrated instantaneous power. Component integration and test results are shown for the dispenser cathode electron gun, fast switching controls, high voltage stand-off insulator, brazed anode, and vacuum system. The current multisource prototype has been operated for over 100 hours without failure, and additional testing is needed to discover the limiting component. Example focal spot measurements and x-ray radiographs are included. Lastly, future development opportunities are highlighted.

  7. Power Law Distributions in Two Community Currencies

    NASA Astrophysics Data System (ADS)

    Kichiji, N.; Nishibe, M.

    2007-07-01

    The purpose of this paper is to highlight certain newly discovered social phenomena that accord with Zipf's law, in addition to the famous natural and social phenomena including word frequencies, earthquake magnitude, city size, income1 etc. that are already known to follow it. These phenomena have recently been discovered within the transaction amount (payments or receipts) distributions within two different Community Currencies (CC) that had been initiated as social experiments. One is a local CC circulating in a specific geographical area, such as a town. The other is a virtual CC used among members who belong to a certain community of interest (COI) on the Internet. We conducted two empirical studies to estimate the economic vitalization effects they had on their respective local economies. The results we found were that the amount of transactions (payments and receipts) of the two CCs was distributed according to a power-law distribution with a unity rank exponent. In addition, we found differences between the two CCs with regard to the shapes of their distribution over a low-transaction range. The result may originate from the difference in methods of issuing CCs or in the magnitudes of the minimum-value unit; however, this result calls for further investigation.

  8. Klystron Cluster Scheme for ILC High Power RF Distribution

    SciTech Connect

    Nantista, Christopher; Adolphsen, Chris; /SLAC

    2009-07-06

    We present a concept for powering the main linacs of the International Linear Collider (ILC) by delivering high power RF from the surface via overmoded, low-loss waveguides at widely spaced intervals. The baseline design employs a two-tunnel layout, with klystrons and modulators evenly distributed along a service tunnel running parallel to the accelerator tunnel. This new idea eliminates the need for the service tunnel. It also brings most of the warm heat load to the surface, dramatically reducing the tunnel water cooling and HVAC requirements. In the envisioned configuration, groups of 70 klystrons and modulators are clustered in surface buildings every 2.5 km. Their outputs are combined into two half-meter diameter circular TE{sub 01} mode evacuated waveguides. These are directed via special bends through a deep shaft and along the tunnel, one upstream and one downstream. Each feeds approximately 1.25 km of linac with power tapped off in 10 MW portions at 38 m intervals. The power is extracted through a novel coaxial tap-off (CTO), after which the local distribution is as it would be from a klystron. The tap-off design is also employed in reverse for the initial combining.

  9. A MILP-Based Distribution Optimal Power Flow Model for Microgrid Operation

    SciTech Connect

    Liu, Guodong; Starke, Michael R; Zhang, Xiaohu; Tomsovic, Kevin

    2016-01-01

    This paper proposes a distribution optimal power flow (D-OPF) model for the operation of microgrids. The proposed model minimizes not only the operating cost, including fuel cost, purchasing cost and demand charge, but also several performance indices, including voltage deviation, network power loss and power factor. It co-optimizes the real and reactive power form distributed generators (DGs) and batteries considering their capacity and power factor limits. The D-OPF is formulated as a mixed-integer linear programming (MILP). Numerical simulation results show the effectiveness of the proposed model.

  10. Test report light duty utility arm power distribution system (PDS)

    SciTech Connect

    Clark, D.A.

    1996-03-04

    The Light Duty Utility Arm (LDUA) Power Distribution System has completed vendor and post-delivery acceptance testing. The Power Distribution System has been found to be acceptable and is now ready for integration with the overall LDUA system.

  11. Efficiency and power loss in d. c. chopper circuits. [Theoretical calculation

    SciTech Connect

    Beck, M.O.

    1981-01-01

    The object of this paper was to investigate the efficiency and source of power losses of various classes of dc chopper circuits. The study involved a theoretical calculation of the power losses, supported by a considerable amount of practical work on full power-rated traction motor test bed. 3 refs.

  12. Satellite control of electric power distribution

    NASA Technical Reports Server (NTRS)

    Bergen, L.

    1981-01-01

    An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.

  13. Estimation of initiating event distribution at nuclear power plants by Bayesian procedure

    SciTech Connect

    Chen Guangming; Chu, T.L.

    1995-12-31

    Initiating events at nuclear power plants such as human errors or components failures may lead to a nuclear accident. The study of the frequency of these events or the distribution of the failure rate is necessary in probabilistic risk assessment for nuclear power plants. This paper presents Bayesian modelling methods for the analysis of the distribution of the failure rate. The method can also be utilized in other related fields especially where the data is sparse. An application of the Bayesian modelling in the analysis of distribution of the time to recover Loss of Off-Site Power ( LOSP) is discussed in the paper.

  14. Combined effect of CVR and penetration of DG in the voltage profile and losses of lowvoltage secondary distribution networks

    NASA Astrophysics Data System (ADS)

    Bokhari, Abdullah

    Demarcations between traditional distribution power systems and distributed generation (DG) architectures are increasingly evolving as higher DG penetration is introduced in the system. The concerns in existing electric power systems (EPSs) to accommodate less restrictive interconnection policies while maintaining reliability and performance of power delivery have been the major challenge for DG growth. In this dissertation, the work is aimed to study power quality, energy saving and losses in a low voltage distributed network under various DG penetration cases. Simulation platform suite that includes electric power system, distributed generation and ZIP load models is implemented to determine the impact of DGs on power system steady state performance and the voltage profile of the customers/loads in the network under the voltage reduction events. The investigation designed to test the DG impact on power system starting with one type of DG, then moves on multiple DG types distributed in a random case and realistic/balanced case. The functionality of the proposed DG interconnection is designed to meet the basic requirements imposed by the various interconnection standards, most notably IEEE 1547, public service commission, and local utility regulation. It is found that implementation of DGs on the low voltage secondary network would improve customer's voltage profile, system losses and significantly provide energy savings and economics for utilities. In a network populated with DGs, utility would have a uniform voltage profile at the customers end as the voltage profile becomes more concentrated around targeted voltage level. The study further reinforced the concept that the behavior of DG in distributed network would improve voltage regulation as certain percentage reduction on utility side would ensure uniform percentage reduction seen by all customers and reduce number of voltage violations.

  15. Power loss in open cavity diodes and a modified Child-Langmuir law

    SciTech Connect

    Biswas, Debabrata; Kumar, Raghwendra; Puri, R.R.

    2005-09-15

    Diodes used in most high power devices are inherently open. It is shown that under such circumstances, there is a loss of electromagnetic radiation leading to a lower critical current as compared to closed diodes. The power loss can be incorporated in the standard Child-Langmuir framework by introducing an effective potential. The modified Child-Langmuir law can be used to predict the maximum power loss for a given plate separation and potential difference as well as the maximum transmitted current for this power loss. The effectiveness of the theory is tested numerically.

  16. Patch Network for Power Allocation and Distribution in Smart Materials

    NASA Technical Reports Server (NTRS)

    Golembiewski, Walter T.

    2000-01-01

    The power allocation and distribution (PAD) circuitry is capable of allocating and distributing a single or multiple sources of power over multi-elements of a power user grid system. The purpose of this invention is to allocate and distribute power that is collected by individual patch rectennas to a region of specific power-user devices, such as actuators. The patch rectenna converts microwave power into DC power. Then this DC power is used to drive actuator devices. However, the power from patch rectennas is not sufficient to drive actuators unless all the collected power is effectively used to drive another group by allocation and distribution. The power allocation and distribution (PAD) circuitry solves the shortfall of power for devices in a large array. The PAD concept is based on the networked power control in which power collected over the whole array of rectennas is allocated to a sub domain where a group of devices is required to be activated for operation. Then the allocated power is distributed to individual element of power-devices in the sub domain according to a selected run-mode.

  17. Effect of spatial distribution of dissipated power on modeling of SMR BAW resonators at high power levels.

    PubMed

    Tag, Andreas; Bader, Bernhard; Huck, Christian; Karolewski, Dominik; Pitschi, Maximilian; Weigel, Robert; Hagelauer, Amelie

    2015-10-01

    The modeling of bulk acoustic wave resonators at elevated power levels has been improved by taking the spatial distribution of the dominating loss mechanisms into account. The spatial distribution of the dissipated power enables more accurate modeling of the temperature increase caused by the applied power. Thus, it is also possible to more accurately model the frequency shifts of the resonators' impedance curves resulting from the temperature increase caused by the applied power. Simulation and measurement results for the temperatures and impedances of the resonators with different layerstacks at high power loads are presented. The simulation and measurement results are in good agreement, confirming the presented modeling approach. Furthermore, the de-embedding procedure used to obtain vectorial scattering parameters of the resonators during high power loads, the according measurement setup, and the procedure for measuring absolute temperatures by infrared thermography are discussed. PMID:26470048

  18. Power-Law Distributions Based on Exponential Distributions: Latent Scaling, Spurious Zipf's Law, and Fractal Rabbits

    NASA Astrophysics Data System (ADS)

    Chen, Yanguang

    2015-03-01

    The difference between the inverse power function and the negative exponential function is significant. The former suggests a complex distribution, while the latter indicates a simple distribution. However, the association of the power-law distribution with the exponential distribution has been seldom researched. This paper is devoted to exploring the relationships between exponential laws and power laws from the angle of view of urban geography. Using mathematical derivation and numerical experiments, I reveal that a power-law distribution can be created through a semi-moving average process of an exponential distribution. For the distributions defined in a one-dimension space (e.g. Zipf's law), the power exponent is 1; while for those defined in a two-dimension space (e.g. Clark's law), the power exponent is 2. The findings of this study are as follows. First, the exponential distributions suggest a hidden scaling, but the scaling exponents suggest a Euclidean dimension. Second, special power-law distributions can be derived from exponential distributions, but they differ from the typical power-law distributions. Third, it is the real power-law distributions that can be related with fractal dimension. This study discloses an inherent link between simplicity and complexity. In practice, maybe the result presented in this paper can be employed to distinguish the real power laws from spurious power laws (e.g. the fake Zipf distribution).

  19. Experimental quantum key distribution with simulated ground-to-satellite photon losses and processing limitations

    NASA Astrophysics Data System (ADS)

    Bourgoin, Jean-Philippe; Gigov, Nikolay; Higgins, Brendon L.; Yan, Zhizhong; Meyer-Scott, Evan; Khandani, Amir K.; Lütkenhaus, Norbert; Jennewein, Thomas

    2015-11-01

    Quantum key distribution (QKD) has the potential to improve communications security by offering cryptographic keys whose security relies on the fundamental properties of quantum physics. The use of a trusted quantum receiver on an orbiting satellite is the most practical near-term solution to the challenge of achieving long-distance (global-scale) QKD, currently limited to a few hundred kilometers on the ground. This scenario presents unique challenges, such as high photon losses and restricted classical data transmission and processing power due to the limitations of a typical satellite platform. Here we demonstrate the feasibility of such a system by implementing a QKD protocol, with optical transmission and full post-processing, in the high-loss regime using minimized computing hardware at the receiver. Employing weak coherent pulses with decoy states, we demonstrate the production of secure key bits at up to 56.5 dB of photon loss. We further illustrate the feasibility of a satellite uplink by generating a secure key while experimentally emulating the varying losses predicted for realistic low-Earth-orbit satellite passes at 600 km altitude. With a 76 MHz source and including finite-size analysis, we extract 3374 bits of a secure key from the best pass. We also illustrate the potential benefit of combining multiple passes together: while one suboptimal "upper-quartile" pass produces no finite-sized key with our source, the combination of three such passes allows us to extract 165 bits of a secure key. Alternatively, we find that by increasing the signal rate to 300 MHz it would be possible to extract 21 570 bits of a secure finite-sized key in just a single upper-quartile pass.

  20. Multipulse current source offers low power losses and high reliability

    NASA Technical Reports Server (NTRS)

    1967-01-01

    Pulse current source uses low loss, high reliability, LC circuits to provide the necessary high impedance for magnetic memory cores, frequently used in digital computational equipment. Square-loop reactors replace the semiconductor switches previously used.

  1. Design note about a 75 KVA quiet power distribution system

    SciTech Connect

    Visser, A.T.

    1984-04-05

    This note describes a 75KVA quiet power distribution system for X 653 in neutrino Lab D. It is fed from the regular AC distribution which exists in the building and it has no standby power. Its purpose is to remove electrical disturbances which are present on the regular AC distribution.

  2. Analysis of axially non-uniform loss distribution in 3-phase induction motor considering skew effect

    SciTech Connect

    Kown, B.I.; Kim, B.T.; Jun, C.S.; Park, S.C. )

    1999-05-01

    This paper discusses the phenomena of the axially non-uniform distribution of magnetic flux densities and losses in a 3-phase squirrel cage induction motor of which the rotor bars are skewed. A 2-dimensional complex finite element method taking account of the effects of the skewed rotor bars is utilized for the analysis of characteristics such as copper and iron losses and the loss distributions are examined. The summing up values of non-uniform losses resulted from the finite element analysis are compared with measurement values.

  3. Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

    SciTech Connect

    Jeong, S. C.; Oyaizu, M.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Miyatake, H.; Niki, K.; Okada, M.; Watanabe, Y. X.; Otokawa, Y.; Osa, A.; Ichikawa, S.

    2012-02-15

    We investigated the ion-loss distribution on the sidewall of an electron cyclotron resonance (ECR) plasma chamber using the 18-GHz ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex (TRIAC). Similarities and differences between the ion-loss distributions (longitudinal and azimuthal) of different ion species (i.e., radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions that are typical volatile and nonvolatile elements) was qualitatively discussed to understand the element dependence of the charge breeding efficiency. Especially, the similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

  4. Power-law ansatz in complex systems: Excessive loss of information.

    PubMed

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring. PMID:26764792

  5. Power-law ansatz in complex systems: Excessive loss of information

    NASA Astrophysics Data System (ADS)

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring.

  6. Novel binary PSO algorithm based optimization of transmission expansion planning considering power losses

    NASA Astrophysics Data System (ADS)

    Astuty; Haryono, T.

    2016-04-01

    Transmission expansion planning (TEP) is one of the issue that have to be faced caused by addition of large scale power generation into the existing power system. Optimization need to be conducted to get optimal solution technically and economically. Several mathematic methods have been applied to provide optimal allocation of new transmission line such us genetic algorithm, particle swarm optimization and tabu search. This paper proposed novel binary particle swarm optimization (NBPSO) to determine which transmission line should be added to the existing power system. There are two scenerios in this simulation. First, considering transmission power losses and the second is regardless transmission power losses. NBPSO method successfully obtain optimal solution in short computation time. Compare to the first scenario, the number of new line in second scenario which regardless power losses is less but produces high power losses that cause the cost becoming extremely expensive.

  7. Effect of geometry and operating conditions on spur gear system power loss

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    The results of an analysis of the effects of spur gear size, pitch, width, and ratio on total mesh power loss for a wide range of speeds, torques, and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling, and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine pitched gears had higher peak efficiencies but low part load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full load loss except at low speeds.

  8. 10 CFR 50.63 - Loss of all alternating current power.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., each light-water-cooled nuclear power plant licensed under subpart C of 10 CFR part 52 after the... 10 Energy 1 2012-01-01 2012-01-01 false Loss of all alternating current power. 50.63 Section 50.63..., Limitations, and Conditions of Licenses and Construction Permits § 50.63 Loss of all alternating current...

  9. 10 CFR 50.63 - Loss of all alternating current power.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., each light-water-cooled nuclear power plant licensed under subpart C of 10 CFR part 52 after the... 10 Energy 1 2011-01-01 2011-01-01 false Loss of all alternating current power. 50.63 Section 50.63..., Limitations, and Conditions of Licenses and Construction Permits § 50.63 Loss of all alternating current...

  10. 10 CFR 50.63 - Loss of all alternating current power.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., each light-water-cooled nuclear power plant licensed under subpart C of 10 CFR part 52 after the... 10 Energy 1 2013-01-01 2013-01-01 false Loss of all alternating current power. 50.63 Section 50.63..., Limitations, and Conditions of Licenses and Construction Permits § 50.63 Loss of all alternating current...

  11. 10 CFR 50.63 - Loss of all alternating current power.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., each light-water-cooled nuclear power plant licensed under subpart C of 10 CFR part 52 after the... 10 Energy 1 2014-01-01 2014-01-01 false Loss of all alternating current power. 50.63 Section 50.63..., Limitations, and Conditions of Licenses and Construction Permits § 50.63 Loss of all alternating current...

  12. 10 CFR 50.63 - Loss of all alternating current power.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., each light-water-cooled nuclear power plant licensed under subpart C of 10 CFR part 52 after the... 10 Energy 1 2010-01-01 2010-01-01 false Loss of all alternating current power. 50.63 Section 50.63..., Limitations, and Conditions of Licenses and Construction Permits § 50.63 Loss of all alternating current...

  13. Low-Power Testing of Losses in Millimeter-Wave Transmission Lines for High-Power Applications

    SciTech Connect

    Han, S. T.; Comfoltey, E. N.; Shapiro, Michael; Sirigiri, Jagadishwar R.; Tax, David; Temkin, Richard J; Woskov, P. P.; Chang, Won; Rasmussen, David A

    2008-08-01

    We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3 {+-} 0.1 dB per miter bend using a VNA; and 0.22 {+-} 0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05 {+-} 0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications.

  14. Fuel Cycle Comparison for Distributed Power Technologies

    SciTech Connect

    Elgowainy, A.; Wang, M. Q.

    2008-11-15

    This report examines backup power and prime power systems and addresses the potential energy and environmental effects of substituting fuel cells for existing combustion technologies based on microturbines and internal combustion engines.

  15. Developments in space power components for power management and distribution

    NASA Technical Reports Server (NTRS)

    Renz, D. D.

    1984-01-01

    Advanced power electronic components development for space applications is discussed. The components described include transformers, inductors, semiconductor devices such as transistors and diodes, remote power controllers, and transmission lines.

  16. 14 CFR 25.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... functioning normally. (2) Essential loads, after failure of any one prime mover, power converter, or energy... source of power is required, after any failure or malfunction in any one power supply system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Power source capacity and distribution....

  17. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2006-01-01

    Secondary seal leakage in jet engine applications results in power losses to the engine cycle. Likewise, seal power loss in jet engines not only result in efficiency loss but also increase the heat input into the engine resulting in reduced component lives. Experimental work on labyrinth and annular seals was performed at NASA Glenn Research Center to quantify seal leakage and power loss at various temperatures, seal pressure differentials, and surface speeds. Data from annular and labyrinth seals are compared with previous brush and finger seal test results. Data are also compared to literature. Annular and labyrinth seal leakage rates are 2 to 3 times greater than brush and finger seal rates. Seal leakage decreases with increasing speed but increases with increasing test temperature due to thermal expansion mismatch. Also seal power loss increases with surface speed, seal pressure differential, mass flow rate, and radial clearance. Annular and labyrinth seal power losses were higher than those of brush or finger seal data. The brush seal power loss was 15 to 30 percent lower than annular and labyrinth seal power loss.

  18. 22 CFR 211.9 - Liability for loss damage or improper distribution of commodities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Collection Standards, 4 CFR 104.3. Approval of such termination by CCC is not required, but the... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Liability for loss damage or improper... § 211.9 Liability for loss damage or improper distribution of commodities. (Where the instructions...

  19. 22 CFR 211.9 - Liability for loss damage or improper distribution of commodities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Collection Standards, 4 CFR 104.3. Approval of such termination by CCC is not required, but the... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Liability for loss damage or improper... § 211.9 Liability for loss damage or improper distribution of commodities. (Where the instructions...

  20. 22 CFR 211.9 - Liability for loss damage or improper distribution of commodities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Collection Standards, 4 CFR 104.3. Approval of such termination by CCC is not required, but the... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Liability for loss damage or improper... § 211.9 Liability for loss damage or improper distribution of commodities. (Where the instructions...

  1. A new approach to the minimum weight/loss design of switching power converters

    NASA Technical Reports Server (NTRS)

    Lee, F. C.; Rahman, S.; Wu, C. J.; Kolacki, J.

    1981-01-01

    A new technique using the mathematical nonlinear programming ALAG is proposed to facilitate design optimizations of switching power converters. This computer-aided approach provides a minimum weight (or loss) design down to the details of component level and concurrently satisfies all related power-circuit performance requirements. It also provides such design insights as tradeoffs between power loss and system weight as the switching frequency is increased.

  2. Space Power Management and Distribution Status and Trends

    NASA Technical Reports Server (NTRS)

    Reppucci, G. M.; Biess, J. J.; Inouye, L.

    1984-01-01

    An overview of space power management and distribution (PMAD) is provided which encompasses historical and current technology trends. The PMAD components discussed include power source control, energy storage control, and load power processing electronic equipment. The status of distribution equipment comprised of rotary joints and power switchgear is evaluated based on power level trends in the public, military, and commercial sectors. Component level technology thrusts, as driven by perceived system level trends, are compared to technology status of piece-parts such as power semiconductors, capacitors, and magnetics to determine critical barriers.

  3. Analysis of Apex Seal Friction Power Loss in Rotary Engines

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.; Owen, A. Karl

    2010-01-01

    An analysis of the frictional losses from the apex seals in a rotary engine was developed. The modeling was initiated with a kinematic analysis of the rotary engine. Next a modern internal combustion engine analysis code was altered for use in a rotary engine to allow the calculation of the internal combustion pressure as a function of rotor rotation. Finally the forces from the spring, inertial, and combustion pressure on the seal were combined to provide the frictional horsepower assessment.

  4. Detection of power losses in busbar solder contacts by electroluminescence imaging of solar cells

    NASA Astrophysics Data System (ADS)

    Gazuz, Vladimir; Buerhop, Claudia

    2011-11-01

    Soldered contacts between busbar and interconnected ribbon can be missing or defective due to production or exploitation of solar cells. This causes an increase of total series resistance and thus more power losses in soldered solar cells or whole modules. There are many conventional methods for checking missing solder joints such as optical or mechanical; however they are quite complicated for practical application. We present a new method for quantitative and qualitative checking of the solar cell solder contacts. This method is based on analysis of the line-scan diagrams of the electroluminescence images of a solar cell's area by applying the appropriate voltage between front side and backside. As a theoretical justification we have used the equation for calculation of the electroluminescence emission and the equations for calculation of the voltage distribution and of series resistance in the solar cell's busbar.

  5. The effect of solar array voltage patterns on plasma power losses

    NASA Technical Reports Server (NTRS)

    Mandell, M. J.; Katz, I.; Steen, P. G.; Schnuelle, G. W.

    1980-01-01

    The use of high-voltage solar arrays in space is discussed in connection with the draining of array power by currents flowing between exposed surfaces through the surrounding plasma. The possibility of reducing the power loss by arranging solar cell strings in repeated small-area modules to eliminate any large areas at high potentials is investigated. It is found that the difference in power loss between modular and linear patterned high-voltage arrays is fairly small. Although the use of modular patterns can reduce the effective mean potential by about 10%, for the type of configuration being considered there is also a 10% increase in sheath area, leading to only a few percent change in total power loss. It is concluded that plasma power loss should not be a primary consideration in designing the physical arrangement of high-voltage arrays.

  6. Balancing Type I Risk and Loss of Power in Ordered Bonferroni Procedures.

    ERIC Educational Resources Information Center

    de Cani, John S.

    1984-01-01

    While Bonferroni procedures control the risk of Type I errors, their cost is loss of power. Ordered Bonferroni procedures conserve power for more important tests while sacrificing power for less important tests. Both costs and benefits should be considered when choosing weights for individual tests and the overall level of Type I error protection.…

  7. A Testbed for Deploying Distributed State Estimation in Power Grid

    SciTech Connect

    Jin, Shuangshuang; Chen, Yousu; Rice, Mark J.; Liu, Yan; Gorton, Ian

    2012-07-22

    Abstract—With the increasing demand, scale and data information of power systems, fast distributed applications are becoming more important in power system operation and control. This paper proposes a testbed for evaluating power system distributed applications, considering data exchange among distributed areas. A high-performance computing (HPC) version of distributed state estimation is implemented and used as a distributed application example. The IEEE 118-bus system is used to deploy the parallel distributed state estimation, and the MeDICi middleware is used for data communication. The performance of the testbed demonstrates its capability to evaluate parallel distributed state estimation by leveraging the HPC paradigm. This testbed can also be applied to evaluate other distributed applications.

  8. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  9. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  10. Dynamic power balance for nonlinear waves in unbalanced gain and loss landscapes

    NASA Astrophysics Data System (ADS)

    Kominis, Yannis

    2015-12-01

    The presence of losses in nonlinear photonic structures necessitates the introduction of active parts for wave power compensation resulting in unbalanced gain and loss landscapes where localized beam propagation is, in general, dynamically unstable. Here we provide generic sufficient conditions for the relation between the gain-loss and the refractive index profiles in order to ensure efficient wave trapping and stable propagation for a wide range of beam launching conditions such as initial power, angle of incidence, and position. The stability is a consequence of an underlying dynamic power balance mechanism related to a conserved quantity of wave dynamics.

  11. Inverter power module with distributed support for direct substrate cooling

    DOEpatents

    Miller, David Harold; Korich, Mark D.; Ward, Terence G.; Mann, Brooks S.

    2012-08-21

    Systems and/or methods are provided for an inverter power module with distributed support for direct substrate cooling. An inverter module comprises a power electronic substrate. A first support frame is adapted to house the power electronic substrate and has a first region adapted to allow direct cooling of the power electronic substrate. A gasket is interposed between the power electronic substrate and the first support frame. The gasket is configured to provide a seal between the first region and the power electronic substrate. A second support frame is adapted to house the power electronic substrate and joined to the first support frame to form the seal.

  12. Electric Transport Traction Power Supply System With Distributed Energy Sources

    NASA Astrophysics Data System (ADS)

    Abramov, E. Y.; Schurov, N. I.; Rozhkova, M. V.

    2016-04-01

    The paper states the problem of traction substation (TSS) leveling of daily-load curve for urban electric transport. The circuit of traction power supply system (TPSS) with distributed autonomous energy source (AES) based on photovoltaic (PV) and energy storage (ES) units is submitted here. The distribution algorithm of power flow for the daily traction load curve leveling is also introduced in this paper. In addition, it illustrates the implemented experiment model of power supply system.

  13. Automated distribution system management for multichannel space power systems

    NASA Technical Reports Server (NTRS)

    Fleck, G. W.; Decker, D. K.; Graves, J.

    1983-01-01

    A NASA sponsored study of space power distribution system technology is in progress to develop an autonomously managed power system (AMPS) for large space power platforms. The multichannel, multikilowatt, utility-type power subsystem proposed presents new survivability requirements and increased subsystem complexity. The computer controls under development for the power management system must optimize the power subsystem performance and minimize the life cycle cost of the platform. A distribution system management philosophy has been formulated which incorporates these constraints. Its implementation using a TI9900 microprocessor and FORTH as the programming language is presented. The approach offers a novel solution to the perplexing problem of determining the optimal combination of loads which should be connected to each power channel for a versatile electrical distribution concept.

  14. Automation of Space Station module power management and distribution system

    NASA Technical Reports Server (NTRS)

    Bechtel, Robert; Weeks, Dave; Walls, Bryan

    1990-01-01

    Viewgraphs on automation of space station module (SSM) power management and distribution (PMAD) system are presented. Topics covered include: reasons for power system automation; SSM/PMAD approach to automation; SSM/PMAD test bed; SSM/PMAD topology; functional partitioning; SSM/PMAD control; rack level autonomy; FRAMES AI system; and future technology needs for power system automation.

  15. New algorithms for the Vavilov distribution calculation and the corresponding energy loss sampling

    SciTech Connect

    Chibani, O. |

    1998-10-01

    Two new algorithms for the fast calculation of the Vavilov distribution within the interval 0.01 {le} {kappa} {le} 10, where neither the Gaussian approximation nor the Landau distribution may be used, are presented. These algorithms are particularly convenient for the sampling of the corresponding random energy loss. A comparison with the exact Vavilov distribution for the case of protons traversing Al slabs is given.

  16. Low-Power Testing of Losses in Millimeter-Wave Transmission Lines for High-Power Applications

    PubMed Central

    Han, S. T.; Comfoltey, E. N.; Shapiro, M. A.; Sirigiri, J. R.; Tax, D. S.; Temkin, R. J.; Woskov, P. P.; Rasmussen, D. A.

    2008-01-01

    We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3±0.1 dB per miter bend using a VNA; and 0.22±0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05±0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications. PMID:19081774

  17. Low-Power Testing of Losses in Millimeter-Wave Transmission Lines for High-Power Applications.

    PubMed

    Han, S T; Comfoltey, E N; Shapiro, M A; Sirigiri, J R; Tax, D S; Temkin, R J; Woskov, P P; Rasmussen, D A

    2008-11-01

    We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3±0.1 dB per miter bend using a VNA; and 0.22±0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05±0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications. PMID:19081774

  18. Comparing Different Fault Identification Algorithms in Distributed Power System

    NASA Astrophysics Data System (ADS)

    Alkaabi, Salim

    A power system is a huge complex system that delivers the electrical power from the generation units to the consumers. As the demand for electrical power increases, distributed power generation was introduced to the power system. Faults may occur in the power system at any time in different locations. These faults cause a huge damage to the system as they might lead to full failure of the power system. Using distributed generation in the power system made it even harder to identify the location of the faults in the system. The main objective of this work is to test the different fault location identification algorithms while tested on a power system with the different amount of power injected using distributed generators. As faults may lead the system to full failure, this is an important area for research. In this thesis different fault location identification algorithms have been tested and compared while the different amount of power is injected from distributed generators. The algorithms were tested on IEEE 34 node test feeder using MATLAB and the results were compared to find when these algorithms might fail and the reliability of these methods.

  19. Energy loss distributions of 7 TeV protons axially channeled in the bent <1 1 0> Si crystal

    NASA Astrophysics Data System (ADS)

    Stojanov, Nace; Petrović, Srdjan

    2016-04-01

    In this article, the energy loss distributions of relativistic protons axially channeled in the bent <1 1 0> Si crystal are studied. The crystal thickness is equal to 1 mm, which corresponds to the reduced crystal thickness, Λ, equal to 1.22, whereas the bending angle, α, was varied from 0 to 30 μrad. The proton energy of 7 TeV was chosen in accordance with the concept of using the bent crystals as a tool for selective deflection of the beam halo particles from the LUA9 experiment at LHC. For the continuum interaction potential of the proton and the crystal the Molière's expression was used and the energy loss of a proton was calculated by applying the trajectory dependent stopping power model. Further, the uncertainness of the scattering angle of the proton caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The energy loss distribution of the channeled protons was obtained via the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. The analysis of the obtained theoretical data shows that the shape of the energy loss distribution strongly depends on the horizontal or vertical direction of the curvature of the crystal. The number of dechanneled protons as a function of the bending angle also strongly depends on the direction of the crystal's curvature. As a result, the dechanneling rates and ranges, obtained from the Gompertz type sigmoidal fitting functions, have different sets of values for different bending orientations. We have also studied the influence of the proton beam divergence on the energy loss distribution of channeled protons.

  20. Power losses in PWM-VSI inverter using NPT or PT IGBT devices

    SciTech Connect

    Blaabjerg, F.; Munk-Nielsen, S.; Pedersen, J.K.; Jaeger, U.

    1995-05-01

    This paper investigates the power losses for two different IGBT technologies (Non Punch Through and Punch Through) for use in PWM-VSI inverters in order to choose the right device technology for a given application. A loss model of the inverter is developed based on experimental determination of the power losses. The loss model is used on two different modulation strategies which are a sine wave with a third harmonic added and a 60{degree}-PWM modulation where only two inverterlegs are active at the same time. The two IGBT technologies are characterized on an advanced measurement system which is described. The total power losses in the inverter are estimated simulation at different conditions and it is concluded that the Non Punch Through technology is most useful for higher switching frequencies, while the Punch Through technology is special useful at lower switching frequencies and high load currents. It is also concluded the 60{degree}-PWM modulation has the lowest power losses and the power losses are almost independent of phase angle cos({phi}) for normal motor operation.

  1. Thresholded Power law Size Distributions of Instabilities in Astrophysics

    NASA Astrophysics Data System (ADS)

    Aschwanden, Markus J.

    2015-11-01

    Power-law-like size distributions are ubiquitous in astrophysical instabilities. There are at least four natural effects that cause deviations from ideal power law size distributions, which we model here in a generalized way: (1) a physical threshold of an instability; (2) incomplete sampling of the smallest events below a threshold x0; (3) contamination by an event-unrelated background xb; and (4) truncation effects at the largest events due to a finite system size. These effects can be modeled in the simplest terms with a “thresholded power law” distribution function (also called generalized Pareto [type II] or Lomax distribution), N(x){dx}\\propto {(x+{x}0)}-a{dx}, where x0 > 0 is positive for a threshold effect, while x0 < 0 is negative for background contamination. We analytically derive the functional shape of this thresholded power law distribution function from an exponential growth evolution model, which produces avalanches only when a disturbance exceeds a critical threshold x0. We apply the thresholded power law distribution function to terrestrial, solar (HXRBS, BATSE, RHESSI), and stellar flare (Kepler) data sets. We find that the thresholded power law model provides an adequate fit to most of the observed data. Major advantages of this model are the automated choice of the power law fitting range, diagnostics of background contamination, physical instability thresholds, instrumental detection thresholds, and finite system size limits. When testing self-organized criticality models that predict ideal power laws, we suggest including these natural truncation effects.

  2. Theory of ac loss in power transmission cables with second generation high temperature superconductor wires

    SciTech Connect

    Clem, J. R.; Malozemoff, A. P.

    2010-02-22

    While a considerable amount of work has been done in an effort to understand ac losses in power transmission cables made of first generation high temperature superconductor (HTS) wires, use of second generation (2G) HTS wires brings in some new considerations. The high critical current density of the HTS layer in 2G wires reduces the surface superconductor hysteretic losses, for which a new formula is derived. Instead, gap and polygonal losses, flux transfer losses in imbalanced two-layer cables and ferromagnetic losses for wires with NiW substrates constitute the principal contributions. A formula for the flux transfer losses is also derived with a paramagnetic approximation for the substrate. Current imbalance and losses associated with the magnetic substrate can be minimized by orienting the substrates of the inner winding inward and the outer winding outward.

  3. AC current distribution and losses in multifilamentary superconductors exposed to longitudinal magnetic field

    SciTech Connect

    Le Naour, S.; Lacaze, A.; Laumond, Y.; Estop, P.; Verhaege, T.

    1996-07-01

    The current distribution and also AC losses, in a multifilamentary superconductor carrying a transport current, are influenced by the self and the external magnetic field. By using the Maxwell equations, a model has been developed in order to calculate the temporal evolution of current distribution in a single wire exposed or not to external magnetic field. This model is based on the actual relationship of electrical field E with current density J and takes into account the twist pitch of the wire. AC losses are calculated by adding all local losses through the cross section. This paper presents calculations of the influence of the cable twist coupled with the longitudinal magnetic field, and also gives some ideas how to decrease losses.

  4. Stability analysis of a two-stage tapered gyrotron traveling-wave tube amplifier with distributed losses

    SciTech Connect

    Hung, C. L.; Lian, Y. H.; Cheng, N. H.; Yeh, Y. S.; Chang, T. H.

    2012-11-15

    The two-stage tapered gyrotron traveling-wave tube (gyro-TWT) amplifier has achieved wide bandwidth in the millimeter wave range. However, possible oscillations in each stage limit this amplifier's operating beam current and thus its output power. To further enhance the amplifier's stability, distributed losses are applied to the interaction circuit of the two-stage tapered gyro-TWT. A self-consistent particle-tracing code is used for analyzing the beam-wave interactions. The stability analysis includes the effects of the wall losses and the length of each stage on the possible oscillations. Simulation results reveal that the distributed-loss method effectively stabilizes all the oscillations in the two stages. Under stable operating conditions, the device is predicted to produce a peak power of 60 kW with an efficiency of 29% and a saturated gain of 52 dB in the Ka-band. The 3-dB bandwidth is 5.7 GHz, which is approximately 16% of the center frequency.

  5. Low-loss Transmission Lines for High-power Terahertz Radiation

    NASA Astrophysics Data System (ADS)

    Nanni, Emilio Alessandro; Jawla, Sudheer Kumar; Shapiro, Michael A.; Woskov, Paul P.; Temkin, Richard J.

    2012-07-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE11 mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE11 mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE11 mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends.

  6. Low-Loss Transmission Lines for High-Power Terahertz Radiation.

    PubMed

    Nanni, Emilio A; Jawla, Sudheer K; Shapiro, Michael A; Woskov, Paul P; Temkin, Richard J

    2012-07-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE(11) mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE(11) mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE(11) mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends. PMID:23162673

  7. Low-Loss Transmission Lines for High-Power Terahertz Radiation

    PubMed Central

    Nanni, Emilio A.; Jawla, Sudheer K.; Shapiro, Michael A.; Woskov, Paul P.; Temkin, Richard J.

    2012-01-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE11 mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE11 mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE11 mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends. PMID:23162673

  8. Distributed Power Sources for Mars Colonization

    NASA Astrophysics Data System (ADS)

    Miley, George H.; Shaban, Yasser

    2003-01-01

    One of the fundamental needs for Mars colonization is an abundant source of energy. The total energy system will probably use a mixture of sources based on solar energy, fuel cells, and nuclear energy. Here we concentrate on the possibility of developing a distributed system employing several unique new types of nuclear energy sources, specifically small fusion devices using inertial electrostatic confinement and portable ``battery type'' proton reaction cells.

  9. Electricity distribution network power quality regulation

    NASA Astrophysics Data System (ADS)

    Lopez Sanchez, Jose Maria

    The regulation of the electricity distribution utilities has evolved to a scenario based on competition and cost-effectiveness. This cost reduction may affect the quality performance. A quality regulatory proposal based on yardstick competition is presented in this Ph.D. thesis. The proposal focuses on the continuity of supply in the electricity distribution networks. The competition is against objective values of the selected zonal quality indices that are computed using a probabilistic model that takes into account the historical behavior of the distribution network and considers the quality indices as random variables. A monitoring scheme has been developed to obtain the basic reliability indices from the rough data. A methodology to segment the supplied area is proposed. The implementation plan of the regulatory proposal and the incentive/penalty scheme to encourage utilities to improve their quality indices, are also presented. An implementation study case of the scheme is shown. The conceptual framework of this proposal and the different regulations of the continuity of supply of several countries are also reviewed in detail.

  10. Calculated radiative power losses from mid- and high-Z impurities in Tokamak plasmas

    NASA Astrophysics Data System (ADS)

    Fournier, Kevin B.; May, M. J.; Pacella, D.; Gregory, B. C.; Rice, J. E.; Terry, J. L.; Finkenthal, M.; Goldstein, W. H.

    1998-09-01

    This paper summarizes recent calculations of the radiative cooling coefficient for molybdenum (Z=42), krypton (Z=36) and argon (Z=18). The radiative processes considered are collisional-radiative line emission, dielectronic recombination line emission, and radiative recombination and bremsstrahlung continuum emission. Collisional-radiative line emission dominates the power loss channels for a given impurity at all but the highest plasma electron temperatures. The atomic data for the line emission are computed ab initio with the HULLAC atomic physics suite of codes. Relativistic, ab initio atomic physics data are used to compute ionization and recombination rate coefficients; the resulting charge state distribution and recombination rates are used to estimate the radiative power from recombination processes. The calculations in the present work are benchmarked against absolute measurements of ion brightness profiles in the Frascati Tokamak Upgrade plasma. Integrated measurements from tokamak plasmas such as bolometry are then simulated. The atomic physics data used to predict the emissivity of individual ions is validated; the calculated cooling coefficients agree well with bolometric measurements.

  11. Description of a 20 kilohertz power distribution system

    NASA Technical Reports Server (NTRS)

    Hansen, I. G.

    1986-01-01

    A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution links multiphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

  12. Description of a 20 Kilohertz power distribution system

    NASA Technical Reports Server (NTRS)

    Hansen, I. G.

    1986-01-01

    A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

  13. Effect of geometry and operating conditions on spur gear system power loss

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    The results of an analysis of the effects of spur gear size, pitch, width and ratio on total mesh power loss for a wide range of speeds, torques and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine-pitched gears had higher peak efficiencies but lower part-load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full-load loss except at low speeds.

  14. Implementation of genetic algorithm for distribution systems loss minimum re-configuration

    SciTech Connect

    Nara, K.; Shiose, A. ); Kitagawa, M.; Ishihara, T. )

    1992-08-01

    In this paper, a distribution systems loss minimum reconfiguration method by genetic algorithm is proposed. The problem is a complex mixed integer programming problem and is very difficult to solve by a mathematical programming approach. A genetic algorithm (GA) is a search or optimization algorithm based on the mechanics of natural selection and natural genetics. Since GA is suitable to solve combinatorial optimization problems, it can be successfully applied to problems of loss minimum in distribution systems. Numerical examples demonstrate the validity and effectiveness of the proposed methodology.

  15. Stable coaxial-waveguide gyrotron backward-wave oscillator with distributed losses

    SciTech Connect

    Hung, C. L.

    2010-10-15

    This study analyzes the performance of a coaxial-waveguide gyrotron backward-wave oscillator (gyro-BWO) operating at the fundamental harmonic by considering mode competition, which may be attributed to higher-order axial modes and competing transverse modes. In the coaxial waveguide with a short length and uniform cross section, the threshold currents of the higher-order axial modes are substantially higher than the operating current. Additionally, when the beam voltage or the magnetic field is adjusted, the oscillation that neighbors the minimum start-oscillation current of a transverse mode has a positive-k{sub z} field profile, and is excited near the cutoff frequency. As a result, the distributed wall losses at the downstream end of the interaction structure effectively damp the positive-k{sub z} field, and raise significantly the minimum start-oscillation currents of the competing transverse modes. This study also investigates how the parameters, including lossy section length, outer wall resistivity, inner wall resistivity, and ratio of the outer radius to the inner radius, affect the start-oscillation currents of the competing transverse modes in order to obtain stable operation conditions in the frequency tuning range. As is forecasted, when using a 15 A electron beam, the Ka-band coaxial gyro-BWO produces an output power of 137 kW and 3 dB bandwidth of 4.2% by magnetic tuning and an output power of 145 kW and 3dB bandwidth of 2.0% by beam voltage tuning.

  16. Thirty-Third Annual Power Distribution Conference

    SciTech Connect

    Oerting, J.A. Jr.

    1980-01-01

    A description is given of how the Gulf Power Company which serves 10 westernmost counties of Florida deals with hurricanes. Gulf's hurricane procedures currently contain 661 pages of detailed information for each area of responsibility, including the general concept for restoration of damage, as well as details describing how this will be accomplished. Included are area storm center locations, personnel assignments, material allocations, vehicle assignments, radio frequencies, news media contacts, special priorities for restoration of service, details of logistics associated with lodging and feeding, telephone center operation to take incoming calls from customers and all of the other functions.

  17. A study of power conditioning and power distribution and components

    NASA Technical Reports Server (NTRS)

    Horton, H. M.; Honnell, M. A.

    1973-01-01

    A comprehensive simulation and analysis performed on the operation of the regulator part of the Charger/Battery/Regulator Module (CBRM) are detailed. The CBRM is utilized as an integral component of the Skylab/Apollo Telescope Mount (ATM) electrical power system and contains a switching mode electronic regulator. Implementing circuit analysis techniques, pertinent voltages and currents are calculated; these, in turn, are incorporated into the regulator system study. Investigation of the turn-on and turn-off times associated with the switching circuitry is performed and an examination is made on these calculations. A simulation model computer program is utilized to generate graphs that relate various CBRM parameters to one another.

  18. 99. POWER DISTRIBUTION UNITS FOR BATTERIES AND RECTIFIERS, NORTHEAST SIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    99. POWER DISTRIBUTION UNITS FOR BATTERIES AND RECTIFIERS, NORTHEAST SIDE OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  19. Power distribution in two-dimensional optical network channels

    NASA Astrophysics Data System (ADS)

    Wang, Dong-Xue; Karim, Mohammad A.

    1996-04-01

    The power distribution in two-dimensional optical network channels is analyzed. The maximum number of allowable channels as determined by the characteristics of optical detector is identified, in particular, for neural-network and wavelet-transform applications.

  20. Multi-Code Ab Initio Calculation of Ionization Distributions and Radiation Losses for Tungsten in Tokamak Plasmas

    SciTech Connect

    Ralchenko, Yu.; Abdallah, J. Jr.; Colgan, J.; Fontes, C. J.; Foster, M.; Zhang, H. L.; Bar-Shalom, A.; Oreg, J.; Bauche, J.; Bauche-Arnoult, C.; Bowen, C.; Faussurier, G.; Chung, H.-K.; Hansen, S. B.; Lee, R. W.; Scott, H.; Gaufridy de Dortan, F. de; Poirier, M.; Golovkin, I.; Novikov, V.

    2009-09-10

    We present calculations of ionization balance and radiative power losses for tungsten in magnetic fusion plasmas. The simulations were performed within the framework of Non-Local Thermodynamic Equilibrium (NLTE) Code Comparison Workshops utilizing several independent collisional-radiative models. The calculations generally agree with each other; however, a clear disagreement with experimental ionization distributions at low temperatures 2 keV

  1. Accuracy of telemetry signal power loss in a filter as an estimate for telemetry degradation

    NASA Technical Reports Server (NTRS)

    Koerner, M. A.

    1989-01-01

    When telemetry data is transmitted through a communication link, some degradation in telemetry performance occurs as a result of the imperfect frequency response of the channel. The term telemetry degradation as used here is the increase in received signal power required to offset this filtering. The usual approach to assessing this degradation is to assume that it is equal to the signal power loss in the filtering, which is easily calculated. However, this approach neglects the effects of the nonlinear phase response of the filter, the effect of any reduction of the receiving system noise due to the filter, and intersymbol interference. Here, an exact calculation of the telemetry degradation, which includes all of the above effects, is compared with the signal power loss calculation for RF filtering of NRZ data on a carrier. The signal power loss calculation is found to be a reasonable approximation when the filter follows the point at which the receiving system noise is introduced, especially if the signal power loss is less than 0.5 dB. The signal power loss approximation is less valid when the receiving system noise is not filtered.

  2. Carolina Power and Light shows the way toward automation of distribution systems

    SciTech Connect

    Not Available

    1984-05-01

    Carolina Power and Light believes that the technology and economics favor automated distribution. It is testing the concept and hardware in a large-scale demonstration it undertook jointly with Westinghouse. The demonstration equipment will serve rural, urban commercial, and urban industrial customers, with metering by two-way transponders that will transmit consumption, demand, and load survey information daily. Random reliability ranges form 98-100%, but overall system reliability is about 85%. The system will lower distribution costs and could cut 10% from distribution losses, while installation costs will be cut in half. The demonstration should identify the most economical installations. 1 table.

  3. A comparative study of electric power distribution systems for spacecraft

    NASA Technical Reports Server (NTRS)

    Stuart, Thomas A.; King, Roger J.

    1990-01-01

    The electric power distribution systems for spacecraft are compared concentrating on two interrelated issues: the choice between dc and high frequency ac, and the converter/inverter topology to be used at the power source. The relative merits of dc and ac distribution are discussed. Specific converter and inverter topologies are identified and analyzed in detail for the purpose of detailed comparison. Finally, specific topologies are recommended for use in dc and ac systems.

  4. High-power CSI-fed induction motor drive with optimal power distribution based control

    NASA Astrophysics Data System (ADS)

    Kwak, S.-S.

    2011-11-01

    In this article, a current source inverter (CSI) fed induction motor drive with an optimal power distribution control is proposed for high-power applications. The CSI-fed drive is configured with a six-step CSI along with a pulsewidth modulated voltage source inverter (PWM-VSI) and capacitors. Due to the PWM-VSI and the capacitor, sinusoidal motor currents and voltages with high quality as well as natural commutation of the six-step CSI can be obtained. Since this CSI-fed drive can deliver required output power through both the six-step CSI and PWM-VSI, this article shows that the kVA ratings of both the inverters can be reduced by proper real power distribution. The optimal power distribution under load requirements, based on power flow modelling of the CSI-fed drive, is proposed to not only minimise the PWM-VSI rating but also reduce the six-step CSI rating. The dc-link current control of the six-step CSI is developed to realise the optimal power distribution. Furthermore, a vector controlled drive for high-power induction motors is proposed based on the optimal power distribution. Experimental results verify the high-power CSI-fed drive with the optimal power distribution control.

  5. Testing the Pareto against the lognormal distributions with the uniformly most powerful unbiased test applied to the distribution of cities.

    PubMed

    Malevergne, Yannick; Pisarenko, Vladilen; Sornette, Didier

    2011-03-01

    Fat-tail distributions of sizes abound in natural, physical, economic, and social systems. The lognormal and the power laws have historically competed for recognition with sometimes closely related generating processes and hard-to-distinguish tail properties. This state-of-affair is illustrated with the debate between Eeckhout [Amer. Econ. Rev. 94, 1429 (2004)] and Levy [Amer. Econ. Rev. 99, 1672 (2009)] on the validity of Zipf's law for US city sizes. By using a uniformly most powerful unbiased (UMPU) test between the lognormal and the power-laws, we show that conclusive results can be achieved to end this debate. We advocate the UMPU test as a systematic tool to address similar controversies in the literature of many disciplines involving power laws, scaling, "fat" or "heavy" tails. In order to demonstrate that our procedure works for data sets other than the US city size distribution, we also briefly present the results obtained for the power-law tail of the distribution of personal identity (ID) losses, which constitute one of the major emergent risks at the interface between cyberspace and reality. PMID:21517562

  6. Testing the Pareto against the lognormal distributions with the uniformly most powerful unbiased test applied to the distribution of cities

    NASA Astrophysics Data System (ADS)

    Malevergne, Yannick; Pisarenko, Vladilen; Sornette, Didier

    2011-03-01

    Fat-tail distributions of sizes abound in natural, physical, economic, and social systems. The lognormal and the power laws have historically competed for recognition with sometimes closely related generating processes and hard-to-distinguish tail properties. This state-of-affair is illustrated with the debate between Eeckhout [Amer. Econ. Rev.SCIEAS0002-828210.1257/0002828043052303 94, 1429 (2004)] and Levy [Amer. Econ. Rev.SCIEAS0002-828210.1257/aer.99.4.1672 99, 1672 (2009)] on the validity of Zipf’s law for US city sizes. By using a uniformly most powerful unbiased (UMPU) test between the lognormal and the power-laws, we show that conclusive results can be achieved to end this debate. We advocate the UMPU test as a systematic tool to address similar controversies in the literature of many disciplines involving power laws, scaling, “fat” or “heavy” tails. In order to demonstrate that our procedure works for data sets other than the US city size distribution, we also briefly present the results obtained for the power-law tail of the distribution of personal identity (ID) losses, which constitute one of the major emergent risks at the interface between cyberspace and reality.

  7. 62. View of amplifiermodulator control system with power distribution panel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    62. View of amplifier-modulator control system with power distribution panel on left, control power supply in middle, and amplifier modulator on right, second floor in transmitter building no. 102. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  8. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment General § 23.1310 Power source...

  9. Analytical Limit Distributions from Random Power-Law Interactions

    NASA Astrophysics Data System (ADS)

    Zaid, Irwin; Mizuno, Daisuke

    2016-07-01

    Nature is full of power-law interactions, e.g., gravity, electrostatics, and hydrodynamics. When sources of such fields are randomly distributed in space, the superposed interaction, which is what we observe, is naively expected to follow a Gauss or Lévy distribution. Here, we present an analytic expression for the actual distributions that converge to novel limits that are in between these already-known limit distributions, depending on physical parameters, such as the concentration of field sources and the size of the probe used to measure the interactions. By comparing with numerical simulations, the origin of non-Gauss and non-Lévy distributions are theoretically articulated.

  10. Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

    NASA Technical Reports Server (NTRS)

    Soltis, James V.

    1998-01-01

    The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

  11. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P.; Donnelly, Matthew K.; Dagle, Jeffery E.

    2006-12-12

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  12. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P.; Donnelly, Matthew K.; Dagle, Jeffery E.

    2011-12-06

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  13. Full-scale prestress loss monitoring of damaged RC structures using distributed optical fiber sensing technology.

    PubMed

    Lan, Chunguang; Zhou, Zhi; Ou, Jinping

    2012-01-01

    For the safety of prestressed structures, prestress loss is a critical issue that will increase with structural damage, so it is necessary to investigate prestress loss of prestressed structures under different damage scenarios. Unfortunately, to date, no qualified techniques are available due to difficulty for sensors to survive in harsh construction environments of long service life and large span. In this paper, a novel smart steel strand based on the Brillouin optical time domain analysis (BOTDA) sensing technique was designed and manufactured, and then series of tests were used to characterize properties of the smart steel strands. Based on prestress loss principle analysis of damaged structures, laboratory tests of two similar beams with different damages were used to verify the concept of full-scale prestress loss monitoring of damaged reinforced concrete (RC) beams by using the smart steel strands. The prestress losses obtained from the Brillouin sensors are compared with that from conventional sensors, which provided the evolution law of prestress losses of damaged RC beams. The monitoring results from the proposed smart strand can reveal both spatial distribution and time history of prestress losses of damaged RC beams. PMID:22778590

  14. Full-Scale Prestress Loss Monitoring of Damaged RC Structures Using Distributed Optical Fiber Sensing Technology

    PubMed Central

    Lan, Chunguang; Zhou, Zhi; Ou, Jinping

    2012-01-01

    For the safety of prestressed structures, prestress loss is a critical issue that will increase with structural damage, so it is necessary to investigate prestress loss of prestressed structures under different damage scenarios. Unfortunately, to date, no qualified techniques are available due to difficulty for sensors to survive in harsh construction environments of long service life and large span. In this paper, a novel smart steel strand based on the Brillouin optical time domain analysis (BOTDA) sensing technique was designed and manufactured, and then series of tests were used to characterize properties of the smart steel strands. Based on prestress loss principle analysis of damaged structures, laboratory tests of two similar beams with different damages were used to verify the concept of full-scale prestress loss monitoring of damaged reinforced concrete (RC) beams by using the smart steel strands. The prestress losses obtained from the Brillouin sensors are compared with that from conventional sensors, which provided the evolution law of prestress losses of damaged RC beams. The monitoring results from the proposed smart strand can reveal both spatial distribution and time history of prestress losses of damaged RC beams. PMID:22778590

  15. Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control subsystem, volume 1

    NASA Technical Reports Server (NTRS)

    Schmeckpeper, K. R.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.

  16. Experimental load capacity and power loss of herringbone grooved gas lubricated journal bearings.

    NASA Technical Reports Server (NTRS)

    Cunningham, R. E.; Fleming, D. P.; Anderson, W. J.

    1971-01-01

    Load capacity, attitude angle, and power loss were determined for 1-1/2-in.-diam herringbone grooved journal bearings operating in air to speeds of 60,000 rpm. Results showed that groove-to-ridge-clearance ratios of 2.0 to 2.4 give a greater load capacity than do ratios outside this optimum range. Agreement with a small-eccentricity pressure perturbation theory was good for groove-to-ridge-clearance ratios in the optimum range. Power loss, relative to that calculated for a plain bearing of the same dimensions, did not vary widely for the range of geometric variables used. Relative power loss generally increased with speed and was generally comparable to that for a plain bearing.

  17. Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution

    SciTech Connect

    Ma, Jian; Huang, Zhenyu; Wong, Pak C.; Ferryman, Thomas A.

    2010-04-30

    Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.

  18. Space station automation of common module power management and distribution

    NASA Technical Reports Server (NTRS)

    Miller, W.; Jones, E.; Ashworth, B.; Riedesel, J.; Myers, C.; Freeman, K.; Steele, D.; Palmer, R.; Walsh, R.; Gohring, J.

    1989-01-01

    The purpose is to automate a breadboard level Power Management and Distribution (PMAD) system which possesses many functional characteristics of a specified Space Station power system. The automation system was built upon 20 kHz ac source with redundancy of the power buses. There are two power distribution control units which furnish power to six load centers which in turn enable load circuits based upon a system generated schedule. The progress in building this specified autonomous system is described. Automation of Space Station Module PMAD was accomplished by segmenting the complete task in the following four independent tasks: (1) develop a detailed approach for PMAD automation; (2) define the software and hardware elements of automation; (3) develop the automation system for the PMAD breadboard; and (4) select an appropriate host processing environment.

  19. Optimal Operation of Energy Storage in Power Transmission and Distribution

    NASA Astrophysics Data System (ADS)

    Akhavan Hejazi, Seyed Hossein

    In this thesis, we investigate optimal operation of energy storage units in power transmission and distribution grids. At transmission level, we investigate the problem where an investor-owned independently-operated energy storage system seeks to offer energy and ancillary services in the day-ahead and real-time markets. We specifically consider the case where a significant portion of the power generated in the grid is from renewable energy resources and there exists significant uncertainty in system operation. In this regard, we formulate a stochastic programming framework to choose optimal energy and reserve bids for the storage units that takes into account the fluctuating nature of the market prices due to the randomness in the renewable power generation availability. At distribution level, we develop a comprehensive data set to model various stochastic factors on power distribution networks, with focus on networks that have high penetration of electric vehicle charging load and distributed renewable generation. Furthermore, we develop a data-driven stochastic model for energy storage operation at distribution level, where the distribution of nodal voltage and line power flow are modelled as stochastic functions of the energy storage unit's charge and discharge schedules. In particular, we develop new closed-form stochastic models for such key operational parameters in the system. Our approach is analytical and allows formulating tractable optimization problems. Yet, it does not involve any restricting assumption on the distribution of random parameters, hence, it results in accurate modeling of uncertainties. By considering the specific characteristics of random variables, such as their statistical dependencies and often irregularly-shaped probability distributions, we propose a non-parametric chance-constrained optimization approach to operate and plan energy storage units in power distribution girds. In the proposed stochastic optimization, we consider

  20. Power losses of soft magnetic composite materials under two-dimensional excitation

    NASA Astrophysics Data System (ADS)

    Zhu, J. G.; Zhong, J. J.; Ramsden, V. S.; Guo, Y. G.

    1999-04-01

    Soft magnetic composite materials produced by powder metallurgy techniques can be very useful for construction of low cost small motors. However, the rotational core losses and the corresponding B-H relationships of soft magnetic composite materials with two-dimensional rotating fluxes have neither been supplied by the manufacturers nor reported in the literature. This article reports the core loss measurement of a soft magnetic composite material, SOMALOY™ 500, Höganäs AB, Sweden, under two-dimensional excitations. The principle of measurement, testing system, and power loss calculation are presented. The results are analyzed and discussed.

  1. Automation of the Athens (Tennessee) electric power distribution system

    SciTech Connect

    Rizy, D.T.; Stovall, J.P.; Usry, G.H.

    1988-01-01

    A large scale distribution automation research and development project has been conducted at the Athens Utilities Board (AUB) in Athens, Tennessee. The project goal was to experiment with the integrated monitoring and control of an entire distribution system from a central distribution control center. The project was sponsored by the U.S. Department of Energy, Office of Energy Storage and Distribution, Electric Energy Systems Program and managed by the Oak Ridge National Laboratory. The experience with the distribution substation monitoring and control, feeder monitoring, voltage and reactive power (vary) control, system (or circuit) reconfiguration for emergency and maintenance situations, and load control are described. A distribution automation applications software package for assessing system configuration, and volt/var control on automated radial distribution feeders was developed and is also described. 8 refs.

  2. Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

    SciTech Connect

    Jeong, S. C.; Oyaizu, M.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Miyatake, H.; Niki, K.; Okada, M.; Watanabe, Y. X.; Otokawa, Y.; Osa, A.; Ichikawa, S.

    2011-03-15

    The ion loss distribution in an electron cyclotron resonance ion source (ECRIS) was investigated to understand the element dependence of the charge breeding efficiency in an electron cyclotron resonance (ECR) charge breeder. The radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions (typical nonvolatile and volatile elements, respectively) were injected into the ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex to breed their charge states. Their respective residual activities on the sidewall of the cylindrical plasma chamber of the source were measured after charge breeding as functions of the azimuthal angle and longitudinal position and two-dimensional distributions of ions lost during charge breeding in the ECRIS were obtained. These distributions had different azimuthal symmetries. The origins of these different azimuthal symmetries are qualitatively discussed by analyzing the differences and similarities in the observed wall-loss patterns. The implications for improving the charge breeding efficiencies of nonvolatile elements in ECR charge breeders are described. The similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

  3. Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Delgado, Irebert R.

    2004-01-01

    Advanced brush and finger seal technologies offer reduced leakage rates over conventional labyrinth seals used in gas turbine engines. To address engine manufacturers concerns about the heat generation and power loss from these contacting seals, brush, finger, and labyrinth seals were tested in the NASA High Speed, High Temperature Turbine Seal Test Rig. Leakage and power loss test results are compared for these competing seals for operating conditions up to 922 K (1200 F) inlet air temperature, 517 KPa (75 psid) across the seal, and surface velocities up to 366 m/s (1200 ft/s).

  4. Emergency preparedness for power outages and wi-fi loss: tips for students and educators of online courses.

    PubMed

    Heithaus, Teresa

    2015-01-01

    Severe weather can impact online education due to a loss of power and Internet access that can last hours or weeks. Planning for such losses is essential to enable participation in the online classroom. This article discusses measures that can be used to maintain an online presence in the event of a power outage or loss of Wi-Fi. PMID:25647316

  5. Parallel Computing Environments and Methods for Power Distribution System Simulation

    SciTech Connect

    Lu, Ning; Taylor, Zachary T.; Chassin, David P.; Guttromson, Ross T.; Studham, Scott S.

    2005-11-10

    The development of cost-effective high-performance parallel computing on multi-processor super computers makes it attractive to port excessively time consuming simulation software from personal computers (PC) to super computes. The power distribution system simulator (PDSS) takes a bottom-up approach and simulates load at appliance level, where detailed thermal models for appliances are used. This approach works well for a small power distribution system consisting of a few thousand appliances. When the number of appliances increases, the simulation uses up the PC memory and its run time increases to a point where the approach is no longer feasible to model a practical large power distribution system. This paper presents an effort made to port a PC-based power distribution system simulator (PDSS) to a 128-processor shared-memory super computer. The paper offers an overview of the parallel computing environment and a description of the modification made to the PDSS model. The performances of the PDSS running on a standalone PC and on the super computer are compared. Future research direction of utilizing parallel computing in the power distribution system simulation is also addressed.

  6. Power laws, discontinuities and regional city size distributions

    USGS Publications Warehouse

    Garmestani, A.S.; Allen, C.R.; Gallagher, C.M.

    2008-01-01

    Urban systems are manifestations of human adaptation to the natural environment. City size distributions are the expression of hierarchical processes acting upon urban systems. In this paper, we test the entire city size distributions for the southeastern and southwestern United States (1990), as well as the size classes in these regions for power law behavior. We interpret the differences in the size of the regional city size distributions as the manifestation of variable growth dynamics dependent upon city size. Size classes in the city size distributions are snapshots of stable states within urban systems in flux. ?? 2008.

  7. Probabilistic assessment of decoupling loss-of-coolant accident and earthquake in nuclear power plant design

    SciTech Connect

    Lu, S.C.; Harris, D.O.

    1981-01-01

    This paper describes a research project conducted at Lawrence Livermore National Laboratory to establish a technical basis for reassessing the requirement of combining large loss-of-coolant-accident (LOCA) and earthquake loads in nuclear power plant design. A large LOCA is defined herein as a double-ended guillotine break of the primary reactor coolant loop piping (the hot leg, cold leg, and crossover) of a pressureized water reactor (PWR). A systematic probability approach has been employed to estimate the probability of a large LOCA directly and indirectly induced by earthquakes. The probability of a LOCA directly induced by earthquakes was assessed by a numerical simulation of pipe rupture of a reactor coolant system. The simulation employed a deterministic fracture mechanics model which dictates the fatigue growth of pre-existing cracks in the pipe. The simulation accounts for the stochastic nature of input elements such as the initial crack size distribution, the crack occurrence rate, crack and leak detection probabilities as functions of crack size, plant transient occurrence rates, the seismic hazard, stress histories, and crack growth model parameters. Effects on final results due to variation an uncertainty of input elements were assessed by a limited sensitivity study. Results of the simulation indicate that the probability of a double-ended guillotine break, either with or without an earthquake, is very small (on the orer of 10/sup -12/). The probability of a leak was found to be several orders of magnitudes greater than that of a complete break.

  8. The Effects of Transients on Photospheric and Chromospheric Power Distributions

    NASA Astrophysics Data System (ADS)

    Samanta, T.; Henriques, V. M. J.; Banerjee, D.; Krishna Prasad, S.; Mathioudakis, M.; Jess, D.; Pant, V.

    2016-09-01

    We have observed a quiet-Sun region with the Swedish 1 m Solar Telescope equipped with the CRISP Imaging SpectroPolarimeter. High-resolution, high-cadence, Hα line scanning images were taken to observe different layers of the solar atmosphere from the photosphere to upper chromosphere. We study the distribution of power in different period bands at different heights. Power maps of the upper photosphere and the lower chromosphere show suppressed power surrounding the magnetic-network elements, known as “magnetic shadows.” These also show enhanced power close to the photosphere, traditionally referred to as “power halos.” The interaction between acoustic waves and inclined magnetic fields is generally believed to be responsible for these two effects. In this study we explore whether small-scale transients can influence the distribution of power at different heights. We show that the presence of transients, like mottles, Rapid Blueshifted Excursions (RBEs), and Rapid Redshifted Excursions (RREs), can strongly influence the power maps. The short and finite lifetime of these events strongly affects all power maps, potentially influencing the observed power distribution. We show that Doppler-shifted transients like RBEs and RREs that occur ubiquitously can have a dominant effect on the formation of the power halos in the quiet Sun. For magnetic shadows, transients like mottles do not seem to have a significant effect on the power suppression around 3 minutes, and wave interaction may play a key role here. Our high-cadence observations reveal that flows, waves, and shocks manifest in the presence of magnetic fields to form a nonlinear magnetohydrodynamic system.

  9. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    PubMed Central

    Dailey, James M.; Agarwal, Anjali; Toliver, Paul; Peters, Nicholas A.

    2015-01-01

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA. PMID:26559465

  10. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    DOE PAGESBeta

    Dailey, James; Agarwal, Anjali; Toliver, Paul; Peters, Nicholas A.

    2015-11-12

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA.

  11. Facial Papules in Fibrosing Alopecia in a Pattern Distribution (Cicatricial Pattern Hair Loss)

    PubMed Central

    Ramanauskaite, Ausrine; Trüeb, Ralph M

    2015-01-01

    Frontal fibrosing alopecia (FFA) and fibrosing alopecia in a pattern distribution (FAPD) represent clinically distinctive conditions characterized by pattern hair loss with evidence of follicular inflammation and fibrosis. Since Kossard's original description, the condition has been recognized to represent a rather generalized than localized process, with extension well beyond the frontotemporal hairline. More recently, peculiar facial papules have been reported in FFA representing facial vellus hair involvement. We report the case of a 42-year-old woman with FAPD associated with the same facial papules, supporting that both entities belong to the same spectrum of cicatricial pattern hair loss. PMID:26622155

  12. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification.

    PubMed

    Dailey, James M; Agarwal, Anjali; Toliver, Paul; Peters, Nicholas A

    2015-01-01

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA. PMID:26559465

  13. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    NASA Astrophysics Data System (ADS)

    Dailey, James M.; Agarwal, Anjali; Toliver, Paul; Peters, Nicholas A.

    2015-11-01

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA.

  14. Comparison of Wind Power and Load Forecasting Error Distributions: Preprint

    SciTech Connect

    Hodge, B. M.; Florita, A.; Orwig, K.; Lew, D.; Milligan, M.

    2012-07-01

    The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

  15. Using Reanalysis Data for the Prediction of Seasonal Wind Turbine Power Losses Due to Icing

    NASA Astrophysics Data System (ADS)

    Burtch, D.; Mullendore, G. L.; Delene, D. J.; Storm, B.

    2013-12-01

    The Northern Plains region of the United States is home to a significant amount of potential wind energy. However, in winter months capturing this potential power is severely impacted by the meteorological conditions, in the form of icing. Predicting the expected loss in power production due to icing is a valuable parameter that can be used in wind turbine operations, determination of wind turbine site locations and long-term energy estimates which are used for financing purposes. Currently, losses due to icing must be estimated when developing predictions for turbine feasibility and financing studies, while icing maps, a tool commonly used in Europe, are lacking in the United States. This study uses the Modern-Era Retrospective Analysis for Research and Applications (MERRA) dataset in conjunction with turbine production data to investigate various methods of predicting seasonal losses (October-March) due to icing at two wind turbine sites located 121 km apart in North Dakota. The prediction of icing losses is based on temperature and relative humidity thresholds and is accomplished using three methods. For each of the three methods, the required atmospheric variables are determined in one of two ways: using industry-specific software to correlate anemometer data in conjunction with the MERRA dataset and using only the MERRA dataset for all variables. For each season, a percentage of the total expected generated power lost due to icing is determined and compared to observed losses from the production data. An optimization is performed in order to determine the relative humidity threshold that minimizes the difference between the predicted and observed values. Eight seasons of data are used to determine an optimal relative humidity threshold, and a further three seasons of data are used to test this threshold. Preliminary results have shown that the optimized relative humidity threshold for the northern turbine is higher than the southern turbine for all methods

  16. Benefits of Power Electronic Interfaces for Distributed Energy Systems

    SciTech Connect

    Kroposki, B.; Pink, C.; DeBlasio, R.; Thomas, H.; Simoes, M.; Sen, P. K.

    2006-01-01

    Optimization of overall electrical system performance is important for the long-term economic viability of distributed energy (DE) systems. With the increasing use of DE systems in industry and its technological advancement, it is becoming more important to understand the integration of these systems with the electric power systems. New markets and benefits for distributed energy applications include the ability to provide ancillary services, improve energy efficiency, enhance power system reliability, and allow customer choice. Advanced power electronic (PE) interfaces will allow DE systems to provide increased functionality through improved power quality and voltage/VAR support, increase electrical system compatibility by reducing the fault contributions, and flexibility in operations with various other DE sources, while reducing overall interconnection costs. This paper examines the system integration and optimization issues associated with DE systems and show the benefits of using PE interfaces for such applications.

  17. Power law tails in the Italian personal income distribution

    NASA Astrophysics Data System (ADS)

    Clementi, F.; Gallegati, M.

    2005-05-01

    We investigate the shape of the Italian personal income distribution using microdata from the Survey on Household Income and Wealth, made publicly available by the Bank of Italy for the years 1977-2002. We find that the upper tail of the distribution is consistent with a Pareto-power law type distribution, while the rest follows a two-parameter lognormal distribution. The results of our analysis show a shift of the distribution and a change of the indexes specifying it over time. As regards the first issue, we test the hypothesis that the evolution of both gross domestic product and personal income is governed by similar mechanisms, pointing to the existence of correlation between these quantities. The fluctuations of the shape of income distribution are instead quantified by establishing some links with the business cycle phases experienced by the Italian economy over the years covered by our dataset.

  18. System-wide power management control via clock distribution network

    DOEpatents

    Coteus, Paul W.; Gara, Alan; Gooding, Thomas M.; Haring, Rudolf A.; Kopcsay, Gerard V.; Liebsch, Thomas A.; Reed, Don D.

    2015-05-19

    An apparatus, method and computer program product for automatically controlling power dissipation of a parallel computing system that includes a plurality of processors. A computing device issues a command to the parallel computing system. A clock pulse-width modulator encodes the command in a system clock signal to be distributed to the plurality of processors. The plurality of processors in the parallel computing system receive the system clock signal including the encoded command, and adjusts power dissipation according to the encoded command.

  19. Electrical Power Distribution and Control Modeling and Analysis

    NASA Technical Reports Server (NTRS)

    Fu, Johnny S.; Liffring, Mark; Mehdi, Ishaque S.

    2001-01-01

    This slide presentation reviews the use of Electrical Power Distribution and Control (EPD&C) Modeling and how modeling can support analysis. The presentation discusses using the EASY5 model to simulate and analyze the Space Shuttle Electric Auxiliary Power Unit. Diagrams of the model schematics are included, as well as graphs of the battery cell impedance, hydraulic load dynamics, and EPD&C response to hydraulic load variations.

  20. Optimal reactive power planning for distribution systems considering intermittent wind power using Markov model and genetic algorithm

    NASA Astrophysics Data System (ADS)

    Li, Cheng

    Wind farms, photovoltaic arrays, fuel cells, and micro-turbines are all considered to be Distributed Generation (DG). DG is defined as the generation of power which is dispersed throughout a utility's service territory and either connected to the utility's distribution system or isolated in a small grid. This thesis addresses modeling and economic issues pertaining to the optimal reactive power planning for distribution system with wind power generation (WPG) units. Wind farms are inclined to cause reverse power flows and voltage variations due to the random-like outputs of wind turbines. To deal with this kind of problem caused by wide spread usage of wind power generation, this thesis investigates voltage and reactive power controls in such a distribution system. Consequently static capacitors (SC) and transformer taps are introduced into the system and treated as controllers. For the purpose of getting optimum voltage and realizing reactive power control, the research proposes a proper coordination among the controllers like on-load tap changer (OLTC), feeder-switched capacitors. What's more, in order to simulate its uncertainty, the wind power generation is modeled by the Markov model. In that way, calculating the probabilities for all the scenarios is possible. Some outputs with consecutive and discrete values have been used for transition between successive time states and within state wind speeds. The thesis will describe the method to generate the wind speed time series from the transition probability matrix. After that, utilizing genetic algorithm, the optimal locations of SCs, the sizes of SCs and transformer taps are determined so as to minimize the cost or minimize the power loss, and more importantly improve voltage profiles. The applicability of the proposed method is verified through simulation on a 9-bus system and a 30-bus system respectively. At last, the simulation results indicate that as long as the available capacitors are able to sufficiently

  1. Analysis on heat loss characteristics of a 10 kV HTS power substation

    NASA Astrophysics Data System (ADS)

    Teng, Yuping; Dai, Shaotao; Song, Naihao; Zhang, Jingye; Gao, Zhiyuan; Zhu, Zhiqin; Zhou, Weiwei; Wei, Zhourong; Lin, Liangzhen; Xiao, Liye

    2014-09-01

    A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

  2. Electric power scheduling - A distributed problem-solving approach

    NASA Technical Reports Server (NTRS)

    Mellor, Pamela A.; Dolce, James L.; Krupp, Joseph C.

    1990-01-01

    Space Station Freedom's power system, along with the spacecraft's other subsystems, needs to carefully conserve its resources and yet strive to maximize overall Station productivity. Due to Freedom's distributed design, each subsystem must work cooperatively within the Station community. There is a need for a scheduling tool which will preserve this distributed structure, allow each subsystem the latitude to satisfy its own constraints, and preserve individual value systems while maintaining Station-wide integrity.

  3. Power law distribution of dividends in horse races

    NASA Astrophysics Data System (ADS)

    Park, K.; Domany, E.

    2001-02-01

    We discovered that the distribution of dividends in Korean horse races follows a power law. A simple model of betting is proposed, which reproduces the observed distribution. The model provides a mechanism to arrive at the true underlying winning probabilities, which are initially unknown, in a self-organized collective fashion, through the dynamic process of betting. Numerical simulations yield excellent agreement with the empirical data.

  4. [Vitamin C loss in vegetables during storage, preparation and distribution in restaurants].

    PubMed

    Moraes, Flávia Aparecida; Cota, Alessandra Miranda; Campos, Flávia Milagres; Pinheiro-Sant'Ana, Helena Maria

    2010-01-01

    The main objective of this study was to evaluate vitamin c loss following vegetable manipulation stages, reception, storage, preparation, and distribution, in commercial and institutional restaurants. Seven vegetables were used: lettuce, carrots, chicory, collard greens, cauliflower, cabbage and tomatoes. Vitamin c analysis was made by high-performance liquid chromatography (hplc). After all manipulation stages, cumulative vitamin c loss was high in vegetables prepared in institutional restaurants and commercial restaurants corresponding to 44.38%-67.03% and 32.90%-71.32%, respectively. In both restaurants, storage accounted for the most expressive loss of vitamin c in the majority of the vegetables. The adoption of measurements to control vitamin c loss in vegetables is suggested, such as purchase and reception according to demand, storage at refrigerated temperatures, monitoring of hygiene and sanitation times, slicing near serving time, cooking preferably steamed, by pressure or stewed, monitoring of cooking time and temperature, and control of the exposure time between preparation and distribution. The results obtained for vitamin c content contribute to the nutritional characterization of vegetables, since studies related to this area are scarce in brazil and in the world. PMID:20169231

  5. Individual loss distribution measurement in 32-branched PON using pulsed pump-probe Brillouin analysis.

    PubMed

    Takahashi, Hiroshi; Ito, Fumihiko; Kito, Chihiro; Toge, Kunihiro

    2013-03-25

    We describe loss distribution measurement in a passive optical network (PON) using pulsed pump-probe Brillouin analysis. A preliminary experiment is demonstrated using a 32-branched PON constructed in the laboratory. We analyze the signal to noise ratio of this measurement and show that the method can realize a 25 dB dynamic range in 90 seconds (10000 times averaging), with an event location resolution of 10 m, and a fiber length identification resolution of 2 m. PMID:23546056

  6. Power Management and Distribution Trades Studies for a Deep-Space Mission Scientific Spacecraft

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Soltis, James V.

    2004-01-01

    As part of NASA's Project Prometheus, the Nuclear Systems Program, NASA GRC performed trade studies on the various Power Management and Distribution (PMAD) options for a deep-space scientific spacecraft which would have a nominal electrical power requirement of 100 kWe. These options included AC (1000Hz and 1500Hz and DC primary distribution at various voltages. The distribution system efficiency, reliability, mass, thermal, corona, space radiation levels and technology readiness of devices and components were considered. The final proposed system consisted of two independent power distribution channels, sourced by two 3-phase, 110 kVA alternators nominally operating at half-rated power. Each alternator nominally supplies 50kWe to one half of the ion thrusters and science modules but is capable of supplying the total power re3quirements in the event of loss of one alternator. This paper is an introduction to the methodology for the trades done to arrive at the proposed PMAD architecture. Any opinions expressed are those of the author(s) and do not necessarily reflect the views of Project Prometheus.

  7. A Cost to Benefit Analysis of a Next Generation Electric Power Distribution System

    NASA Astrophysics Data System (ADS)

    Raman, Apurva

    This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast protection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs. Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this reflects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a

  8. Integrated Computing, Communication, and Distributed Control of Deregulated Electric Power Systems

    SciTech Connect

    Bajura, Richard; Feliachi, Ali

    2008-09-24

    Restructuring of the electricity market has affected all aspects of the power industry from generation to transmission, distribution, and consumption. Transmission circuits, in particular, are stressed often exceeding their stability limits because of the difficulty in building new transmission lines due to environmental concerns and financial risk. Deregulation has resulted in the need for tighter control strategies to maintain reliability even in the event of considerable structural changes, such as loss of a large generating unit or a transmission line, and changes in loading conditions due to the continuously varying power consumption. Our research efforts under the DOE EPSCoR Grant focused on Integrated Computing, Communication and Distributed Control of Deregulated Electric Power Systems. This research is applicable to operating and controlling modern electric energy systems. The controls developed by APERC provide for a more efficient, economical, reliable, and secure operation of these systems. Under this program, we developed distributed control algorithms suitable for large-scale geographically dispersed power systems and also economic tools to evaluate their effectiveness and impact on power markets. Progress was made in the development of distributed intelligent control agents for reliable and automated operation of integrated electric power systems. The methodologies employed combine information technology, control and communication, agent technology, and power systems engineering in the development of intelligent control agents for reliable and automated operation of integrated electric power systems. In the event of scheduled load changes or unforeseen disturbances, the power system is expected to minimize the effects and costs of disturbances and to maintain critical infrastructure operational.

  9. Loss rate of NO y from a power plant plume based on aircraft measurements

    NASA Astrophysics Data System (ADS)

    Gillani, N. V.; Luria, M.; Valente, R. J.; Tanner, R. L.; Imhoff, R. E.; Meagher, J. F.

    1998-09-01

    This study was motivated by the recent work of Buhr et al. [1996] which reported losses of NOy from large power plant plumes as high as 0.25 hour-1, much higher than generally accepted values. If true, conclusions pertaining to the efficiency of ozone and nitrate production in the lower troposphere would need major revisions. The results of Buhr et al. were based on aircraft measurements in four TVA (Tennessee Valley Authority) power plant plumes on July 7, 1995, as part of the Nashville/Middle Tennessee Ozone Study, a measurement program of the Southern Oxidants Study (SOS), whereas the results reported in this paper are also based on measurements made in the same SOS study aboard another instrumented aircraft (the TVA helicopter), in plumes of one of these power plants (the Cumberland Steam Plant in northwestern Tennessee) during five different days in 1994 and 1995. Between the 1994 and 1995 sampling periods, emissions of SO2 at the Cumberland plant were reduced by nearly 95% by installation of scrubbers. Our data from the one 1994 day show that the ratio of excess SO2 to NOy, in the plume core increased significantly with plume age, indicating a potentially high differential loss rate of NOy (excess loss of NOy relative to SO2) of about 0.12 hour-1. However, results based on the larger 1995 data set indicate a low differential NOy loss rate of only 0.00±0.03 hour-1, consistent with accepted low loss rates. Because the SOS-Nashville/Middle Tennessee Ozone Study was not specifically designed to explore the NOy loss issue, the question of NOy loss rates in plumes is not currently resolved and additional focused field studies are needed.

  10. Wind Power Forecasting Error Distributions: An International Comparison; Preprint

    SciTech Connect

    Hodge, B. M.; Lew, D.; Milligan, M.; Holttinen, H.; Sillanpaa, S.; Gomez-Lazaro, E.; Scharff, R.; Soder, L.; Larsen, X. G.; Giebel, G.; Flynn, D.; Dobschinski, J.

    2012-09-01

    Wind power forecasting is expected to be an important enabler for greater penetration of wind power into electricity systems. Because no wind forecasting system is perfect, a thorough understanding of the errors that do occur can be critical to system operation functions, such as the setting of operating reserve levels. This paper provides an international comparison of the distribution of wind power forecasting errors from operational systems, based on real forecast data. The paper concludes with an assessment of similarities and differences between the errors observed in different locations.

  11. Power-law distribution of family names in Japanese societies

    NASA Astrophysics Data System (ADS)

    Miyazima, Sasuke; Lee, Youngki; Nagamine, Tomomasa; Miyajima, Hiroaki

    2000-04-01

    We study the frequency distribution of family names. From a common data base, we count the number of people who share the same family name. This is the size of the family. We find that (i) the total number of different family names in a society scales as a power law of the population, (ii) the total number of family names of the same size decreases as the size increases with a power law and (iii) the relation between size and rank of a family name also shows a power law. These scaling properties are found to be consistent for five different regional communities in Japan.

  12. Emissivity-corrected power loss calibration for lock-in thermography measurements on silicon solar cells

    NASA Astrophysics Data System (ADS)

    Kasemann, Martin; Walter, Benjamin; Meinhardt, Christoph; Ebser, Jan; Kwapil, Wolfram; Warta, Wilhelm

    2008-06-01

    This paper describes power loss calibration procedures with implemented emissivity correction. The determination of our emissivity correction matrix does neither rely on blackbody reference measurements nor on the knowledge of any sample temperatures. To describe the emissivity-corrected power calibration procedures in detail, we review the theory behind lock-in thermography and show experimentally that the lock-in signal is proportional to the power dissipation in the solar cell. Experiments show the successful application of our emissivity correction procedure, which significantly improves the informative value of lock-in thermography images and the reliability of the conclusions drawn from these images.

  13. Proposal of an Innovative Electric Power Distribution System based on Packet Power Transactions

    NASA Astrophysics Data System (ADS)

    Inoue, Jun; Fujii, Yasumasa

    Recently, the introduction of decentralized generators, such as photovoltaic power generations, has been promoted rapidly. In the future, extensive use of PV is thought to give rise to the daytime surplus electricity, and a household will manage the surplus electricity rationally. The purpose of this research is to propose an innovative electric power distribution system based on packet power transactions. First, this paper explains distributed markets of which the price can easily reflect the geographical diversity of renewable energy availability and load curve characteristic within the local area. Second, this paper exemplifies the specific electronic circuit that makes pulse-shaped power transmission to develop the packet power distribution system. Finally, this paper shows the results of multi-agent simulations of electricity trading to evaluate the usefulness of the proposed system.

  14. A Distributed Cooperative Power Allocation Method for Campus Buildings

    SciTech Connect

    Hao, He; Sun, Yannan; Carroll, Thomas E.; Somani, Abhishek

    2015-09-01

    We propose a coordination algorithm for cooperative power allocation among a collection of commercial buildings within a campus. We introduced thermal and power models of a typical commercial building Heating, Ventilation, and Air Conditioning (HVAC) system, and utilize model predictive control to characterize their power flexibility. The power allocation problem is formulated as a cooperative game using the Nash Bargaining Solution (NBS) concept, in which buildings collectively maximize the product of their utilities subject to their local flexibility constraints and a total power limit set by the campus coordinator. To solve the optimal allocation problem, a distributed protocol is designed using dual decomposition of the Nash bargaining problem. Numerical simulations are performed to demonstrate the efficacy of our proposed allocation method

  15. 26 CFR 1.904(f)-4 - Recapture of foreign losses out of accumulation distributions from a foreign trust.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... distributions from a foreign trust. 1.904(f)-4 Section 1.904(f)-4 Internal Revenue INTERNAL REVENUE SERVICE... Without the United States § 1.904(f)-4 Recapture of foreign losses out of accumulation distributions from... the balance in the taxpayer's overall foreign loss account (after applying §§ 1.904(f)-1,...

  16. Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007

    SciTech Connect

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01

    This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

  17. Evaluation of power control concepts using the PMAD systems test bed. [Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Beach, R. F.; Kimnach, G. L.; Jett, T. A.; Trash, L. M.

    1989-01-01

    The Lewis Research Center's Power Management and Distribution (PMAD) System testbed and its use in the evaluation of control concepts applicable to the NASA Space Station Freedom electric power system (EPS) are described. The facility was constructed to allow testing of control hardware and software in an environment functionally similar to the space station electric power system. Control hardware and software have been developed to allow operation of the testbed power system in a manner similar to a supervisory control and data acquisition (SCADA) system employed by utility power systems for control. The system hardware and software are described.

  18. Numerical power balance and free energy loss analysis for solar cells including optical, thermodynamic, and electrical aspects

    SciTech Connect

    Greulich, Johannes Höffler, Hannes; Würfel, Uli; Rein, Stefan

    2013-11-28

    A method for analyzing the power losses of solar cells is presented, supplying a complete balance of the incident power, the optical, thermodynamic, and electrical power losses and the electrical output power. The involved quantities have the dimension of a power density (units: W/m{sup 2}), which permits their direct comparison. In order to avoid the over-representation of losses arising from the ultraviolet part of the solar spectrum, a method for the analysis of the electrical free energy losses is extended to include optical losses. This extended analysis does not focus on the incident solar power of, e.g., 1000 W/m{sup 2} and does not explicitly include the thermalization losses and losses due to the generation of entropy. Instead, the usable power, i.e., the free energy or electro-chemical potential of the electron-hole pairs is set as reference value, thereby, overcoming the ambiguities of the power balance. Both methods, the power balance and the free energy loss analysis, are carried out exemplarily for a monocrystalline p-type silicon metal wrap through solar cell with passivated emitter and rear (MWT-PERC) based on optical and electrical measurements and numerical modeling. The methods give interesting insights in photovoltaic (PV) energy conversion, provide quantitative analyses of all loss mechanisms, and supply the basis for the systematic technological improvement of the device.

  19. Analytical Limit Distributions from Random Power-Law Interactions.

    PubMed

    Zaid, Irwin; Mizuno, Daisuke

    2016-07-15

    Nature is full of power-law interactions, e.g., gravity, electrostatics, and hydrodynamics. When sources of such fields are randomly distributed in space, the superposed interaction, which is what we observe, is naively expected to follow a Gauss or Lévy distribution. Here, we present an analytic expression for the actual distributions that converge to novel limits that are in between these already-known limit distributions, depending on physical parameters, such as the concentration of field sources and the size of the probe used to measure the interactions. By comparing with numerical simulations, the origin of non-Gauss and non-Lévy distributions are theoretically articulated. PMID:27472105

  20. Prestorm estimation of hurricane damage to electric power distribution systems.

    PubMed

    Guikema, Seth D; Quiring, Steven M; Han, Seung-Ryong

    2010-12-01

    Hurricanes frequently cause damage to electric power systems in the United States, leading to widespread and prolonged loss of electric service. Restoring service quickly requires the use of repair crews and materials that must be requested, at considerable cost, prior to the storm. U.S. utilities have struggled to strike a good balance between over- and underpreparation largely because of a lack of methods for rigorously estimating the impacts of an approaching hurricane on their systems. Previous work developed methods for estimating the risk of power outages and customer loss of power, with an outage defined as nontransitory activation of a protective device. In this article, we move beyond these previous approaches to directly estimate damage to the electric power system. Our approach is based on damage data from past storms together with regression and data mining techniques to estimate the number of utility poles that will need to be replaced. Because restoration times and resource needs are more closely tied to the number of poles and transformers that need to be replaced than to the number of outages, this pole-based assessment provides a much stronger basis for prestorm planning by utilities. Our results show that damage to poles during hurricanes can be assessed accurately, provided that adequate past damage data are available. However, the availability of data can, and currently often is, the limiting factor in developing these types of models in practice. Opportunities for further enhancing the damage data recorded during hurricanes are also discussed. PMID:21039701

  1. New-type cable accessories for power distribution

    SciTech Connect

    Sanjo, K.; Kawano, K.; Shiraoka, K.; Yasuda, N.; Yatsuka, K.

    1982-12-01

    This paper describes new types of cable accessories for improving the reliability of power distribution cable systems. The practical development of a 25kV-class cable termination, and a waterproof sleeve for cable joints based on heat-shrinkable components made of irradiated polyolefine is discussed. Furthermore, the theoretical and practical data are given.

  2. High Resolution PV Power Modeling for Distribution Circuit Analysis

    SciTech Connect

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  3. Synthesis of a low loss Mn-Zn ferrite for power applications

    NASA Astrophysics Data System (ADS)

    Tsakaloudi, Vasiliki; Zaspalis, Vassilios

    2016-02-01

    Current market trends of the switching power supplies industry require even lower energy losses in power conversion systems with maintenance of satisfactory initial permeability levels. Typical operation conditions refer to a frequency of 100 kHz, an induction level of 200 mT and a steady state temperature of 100° C. In this work the development of a polycrystalline Mn-Zn ferrite material that exhibits initial relative magnetic permeability above 2500 and very low power losses at 100 kHz, 200 mmT and 100° C is presented. The Mn-Zn ferrite samples were prepared by the conventional solid state reaction method. Sintering was performed under controlled atmosphere conditions. The combinatorial role of TiO2 and CoO together with Zn content, as well as the effects of the process parameters on the magnetic performance of the Mn-Zn ferrite was evaluated. It is shown that the development of the adequate polycrystalline microstructure that is characterized by (a) high sintered density, (b) homogenous grain size that is free of morphological or chemical pinning defects and (c) high resistivity grain boundary structure, can be achieved by means of appropriate compositional and dopant adjustment, anisotropy control and specific resistivity optimization. The newly developed Mn-Zn ferrite is characterized by high sintered density of 4.91 g/cm3, initial magnetic permeability of 2512 (at 10 kHz, 0.1 mT, 25 °C), high saturation magnetic flux density of 560 mT (at 10 kHz, 1200 A/m, 25 °C) and very low power losses (Pv) of 224 mW/cm3 (at 100 kHz, 200 mT, 100 °C) combined with very low power losses of 470 mW/cm3 even at room temperature, establishing it as ideal for power applications.

  4. Statistical Models of Power-law Distributions in Homogeneous Plasmas

    SciTech Connect

    Roth, Ilan

    2011-01-04

    A variety of in-situ measurements in space plasmas point out to an intermittent formation of distribution functions with elongated tails and power-law at high energies. Power-laws form ubiquitous signature of many complex systems, plasma being a good example of a non-Boltzmann behavior for distribution functions of energetic particles. Particles, which either undergo mutual collisions or are scattered in phase space by electromagnetic fluctuations, exhibit statistical properties, which are determined by the transition probability density function of a single interaction, while their non-asymptotic evolution may determine the observed high-energy populations. It is shown that relaxation of the Brownian motion assumptions leads to non-analytical characteristic functions and to generalization of the Fokker-Planck equation with fractional derivatives that result in power law solutions parameterized by the probability density function.

  5. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, John W.; O'Brien, Dennis W.

    1996-01-01

    An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.

  6. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, J.W.; O`Brien, D.W.

    1996-07-09

    An apparatus and method are disclosed for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: (1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and (2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1,000 {micro}m (1 mm or larger), compared to the 250 {micro}m diameter of laser drilling. 5 figs.

  7. The optical power distribution in a dark room

    NASA Astrophysics Data System (ADS)

    Liner, Andrej; Papes, Martin; Vitasek, Jan; Koudelka, Petr; Látal, Jan; Cubik, Jakub; Vašinek, Vladimir

    2012-01-01

    Nowadays, in the field of communications systems radio transmission frequencies are dominant inside buildings. Due to the increasing of large number of users and devices, that use these frequencies, there is danger of accruing interferences and reducing the transmission performance. Therefore, indoor wireless optical systems are beginning to use as an alternative solution. Indoor wireless optical systems can use for communication direct and reflected light rays. This article deals with the measurement of optical power distribution in the model dark room. As a light source we use white power LEDs located on the ceiling of the room. The measurement of the optical power distribution was performed in dark room, which was specially constructed for this purpose. This room was also modelled in LightTools software that allows simulate a real measurement. This article compares the results of the measurement and the simulation.

  8. Exploring empowerment in settings: mapping distributions of network power.

    PubMed

    Neal, Jennifer Watling

    2014-06-01

    This paper brings together two trends in the empowerment literature-understanding empowerment in settings and understanding empowerment as relational-by examining what makes settings empowering from a social network perspective. Specifically, extending Neal and Neal's (Am J Community Psychol 48(3/4):157-167, 2011) conception of network power, an empowering setting is defined as one in which (1) actors have existing relationships that allow for the exchange of resources and (2) the distribution of network power among actors in the setting is roughly equal. The paper includes a description of how researchers can examine distributions of network power in settings. Next, this process is illustrated in both an abstract example and using empirical data on early adolescents' peer relationships in urban classrooms. Finally, implications for theory, methods, and intervention related to understanding empowering settings are explored. PMID:24213301

  9. Distribution of Acoustic Power Spectra for an Isolated Helicopter Fuselage

    NASA Astrophysics Data System (ADS)

    Kusyumov, A. N.; Mikhailov, S. A.; Garipova, L. I.; Batrakov, A. S.; Barakos, G.

    2016-03-01

    The broadband aerodynamic noise can be studied, assuming isotropic flow, turbulence and decay. Proudman's approach allows practical calculations of noise based on CFD solutions of RANS or URANS equations at the stage of post processing and analysis of the solution. Another aspect is the broadband acoustic spectrum and the distribution of acoustic power over a range of frequencies. The acoustic energy spectrum distribution in isotropic turbulence is non monotonic and has a maximum at a certain value of Strouhal number. In the present work the value of acoustic power peak frequency is determined using a prescribed form of acoustic energy spectrum distribution presented in papers by S. Sarkar and M. Y. Hussaini and by G. M. Lilley. CFD modelling of the flow around isolated helicopter fuselage model was considered using the HMB CFD code and the RANS equations.

  10. Multi-kw dc power distribution system study program

    NASA Technical Reports Server (NTRS)

    Berkery, E. A.; Krausz, A.

    1974-01-01

    The first phase of the Multi-kw dc Power Distribution Technology Program is reported and involves the test and evaluation of a technology breadboard in a specifically designed test facility according to design concepts developed in a previous study on space vehicle electrical power processing, distribution, and control. The static and dynamic performance, fault isolation, reliability, electromagnetic interference characterisitics, and operability factors of high distribution systems were studied in order to gain a technology base for the use of high voltage dc systems in future aerospace vehicles. Detailed technical descriptions are presented and include data for the following: (1) dynamic interactions due to operation of solid state and electromechanical switchgear; (2) multiplexed and computer controlled supervision and checkout methods; (3) pulse width modulator design; and (4) cable design factors.