Science.gov

Sample records for power supply regulated

  1. Lightweight Regulated Power Supply

    NASA Technical Reports Server (NTRS)

    Mclyman, C. W.

    1985-01-01

    Power-supply circuit regulates output voltage by adjusting frequency of chopper circuit according to variations. Currently installed in battery charger for electric wheelchair, circuit is well suited to other uses in which light weight is important - for example, in portable computers, radios, and test instruments.

  2. Simple constant-current-regulated power supply

    NASA Technical Reports Server (NTRS)

    Priebe, D. H. E.; Sturman, J. C.

    1977-01-01

    Supply incorporates soft-start circuit that slowly ramps current up to set point at turn-on. Supply consists of full-wave rectifier, regulating pass transistor, current feedback circuit, and quad single-supply operational-amplifier circuit providing control. Technique is applicable to any system requiring constant dc current, such as vacuum tube equipment, heaters, or battery charges; it has been used to supply constant current for instrument calibration.

  3. Improving Power-Supply Regulation for Pulsed Loads

    NASA Technical Reports Server (NTRS)

    Gulick, C. R.; Chan, R. B.

    1982-01-01

    Power supply voltage-regulator circuit speeds up response to sudden load changes. As load increases, additional feedback path is enabled. Path bypasses and provides faster loop response than normal feedback path. Steady-state instability due to faster loop response avoided by progressively disabling bypass loop and allowing normal feedback path to take over.

  4. DC switching regulated power supply for driving an inductive load

    DOEpatents

    Dyer, G.R.

    1983-11-29

    A dc switching regulated power supply for driving an inductive load is provided. The regulator basic circuit is a bridge arrangement of diodes and transistors. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. A dc power supply is connected to the input of the bridge and the output is connected to the load. A servo controller is provided to control the switching rate of the transistors to maintain a desired current to the load. The regulator may be operated in three stages or modes: (1) for current runup in the load, both first and second transistor switch arrays are turned on and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned off, and load current flywheels through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays off, allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load.

  5. DC switching regulated power supply for driving an inductive load

    DOEpatents

    Dyer, George R.

    1986-01-01

    A power supply for driving an inductive load current from a dc power supply hrough a regulator circuit including a bridge arrangement of diodes and switching transistors controlled by a servo controller which regulates switching in response to the load current to maintain a selected load current. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. The regulator may be operated in three "stages" or modes: (1) For current runup in the load, both first and second transistor switch arrays are turned "on" and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned "off", and load current "flywheels" through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays "off", allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load. The three operating states are controlled automatically by the controller.

  6. Voltage Regulator Chip: Power Supplies on a Chip

    SciTech Connect

    2010-09-01

    ADEPT Project: CPES at Virginia Tech is finding ways to save real estate on a computer's motherboard that could be used for other critical functions. Every computer processor today contains a voltage regulator that automatically maintains a constant level of electricity entering the device. These regulators contain bulky components and take up about 30% of a computer's motherboard. CPES at Virginia Tech is developing a voltage regulator that uses semiconductors made of gallium nitride on silicon (GaN-on-Si) and high-frequency soft magnetic material. These materials are integrated on a small, 3D chip that can handle the same amount of power as traditional voltage regulators at 1/10 the size and with improved efficiency. The small size also frees up to 90% of the motherboard space occupied by current voltage regulators.

  7. Power supply

    DOEpatents

    Yakymyshyn, Christopher Paul; Hamilton, Pamela Jane; Brubaker, Michael Allen

    2007-12-04

    A modular, low weight impedance dropping power supply with battery backup is disclosed that can be connected to a high voltage AC source and provide electrical power at a lower voltage. The design can be scaled over a wide range of input voltages and over a wide range of output voltages and delivered power.

  8. Power Supply

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Maxwell Laboratories capacitor charging power supply is the first commercial spinoff from the NASA CCDS program - a consortia of industries and government establishments to accelerate development of ground and space based commercial applications of NASA technology. The power supply transforms and conditions large voltages to charge capacitors used in x-ray sources, medical accelerators, etc. It is lighter, more reliable, more compact and efficient. Originally developed for space lasers, its commercial potential was soon recognized.

  9. Regulation loops for the ring magnet power supplies in the SSC accelerator complex

    SciTech Connect

    Tacconi, E.; Christiansen, C.

    1993-05-01

    The SSC complex consists of five cascaded accelerators: The linear accelerator (linac) and four synchrotrons: The low energy booster (LEB), the medium energy booster (MEB), the high energy booster (HEB), and the collider. Twelve- or 24-pulse phase-controlled SCR power supplies are used to energize the ring magnets. Each power supply has a voltage loop designed to regulate the voltage applied to the magnets. The voltage regulation loops for these synchrotrons and the current regulation for the LEB are analyzed in this work. The digital voltage regulator is fiber-optic isolated from the power converter. It has a closed-loop bandwidth of 150 Hz with band rejections for 60-Hz and 120-Hz perturbations. The LEB has a very precise current regulation system composed of a feedforward compensator, a fast feedback regulator, and a slow synchronous regulator. The current regulation design is corroborated by computer simulations.

  10. Power supply

    DOEpatents

    Hart, Edward J.; Leeman, James E.; MacDougall, Hugh R.; Marron, John J.; Smith, Calvin C.

    1976-01-01

    An electric power supply employs a striking means to initiate ferroelectric elements which provide electrical energy output which subsequently initiates an explosive charge which initiates a second ferroelectric current generator to deliver current to the coil of a magnetic field current generator, creating a magnetic field around the coil. Continued detonation effects compression of the magnetic field and subsequent generation and delivery of a large output current to appropriate output loads.

  11. A novel current and voltage regulated energy discharge power supply 200 A, 600 V

    SciTech Connect

    Visser, A.

    1991-05-01

    The fast spill beam extracted from the 1000 GeV particle accelerator Fermi National Accelerator Laboratory requires two pulsed magnet and power supply systems to steer the beam to the designated experimental area. This beam steering requires a magnetic field integral of 4kGm per magnet for a duration of 4 msec at a rate of one shot per 5 seconds, and limited to 6 shots per 63 seconds. Each shot cannot last any longer than about 100 msec from start to finish. The magnetic field must be constant to within 1% during each 4 msec spill period. This paper describes an energy discharge type power supply and magnet that meet these requirements. This unique power supply has two regulators. One regulator preregulates the storage voltage and the other regulates the required peak current. The magnet and power supply design are interwoven to allow the use of easily available commercial parts for the power supply. Power supply and magnet design should always go hand in hand.

  12. Trends in the use of digital technology for control and regulation of power supplies.

    SciTech Connect

    Carwardine, J.; Lenkszus, F.

    1999-10-22

    Since the availability of computers, accelerator power supplies have relied on digital technology in some way, from such simple tasks as turning the supplies on and off to the supplying of computer-controlled references. However, advances in digital technology, both in performance and cost, allow considerably more than simple control and monitoring. This, coupled with increasing demand for higher performance and monitoring capabilities, has made it appealing to integrate such technology into power supply designs. This paper will review current trends in the use of such advanced technology as embedded DSP controllers, and the application of real-time algorithms to the regulation and control of power supplies for accelerators and other large-scale physics applications.

  13. Programmable high voltage power supply with regulation confined to the high voltage section

    NASA Technical Reports Server (NTRS)

    Castell, Karen D. (Inventor); Ruitberg, Arthur P. (Inventor)

    1994-01-01

    A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

  14. Regulated-current dc power supply for gaseous-discharge lamps

    NASA Technical Reports Server (NTRS)

    Freeman, W.; Huguenin, D.

    1970-01-01

    Controlled current source having a high output resistance feeds continuous-flow hydrogen lamps in vacuum-ultraviolet photometric equipment. The power supply, also used with low-pressure sealed lamps, has a short recovery time and smooth regulation without overshoot.

  15. Tuning magnet power supply

    SciTech Connect

    Han, B.M.; Karady, G.G.; Thiessen, H.A.

    1989-01-01

    The particles in a Rapid Cycling Accelerator are accelerated by rf cavities, which are tuned by dc biased ferrite cores. The tuning is achieved by the regulation of bias current, which is produced by a power supply. The tuning magnet power supply utilizes a bridge circuit, supplied by a three phase rectifier. During the rise of the current, when the particles are accelerated, the current is controlled with precision by the bridge which operates a power amplifier. During the fall of the current, the bridge operates in a switching mode and recovers the energy stored in the ferrites. The recovered energy is stored in a capacitor bank. The bridge circuit is built with 150 power transistors. The drive, protection and control circuit were designed and built from commercial component. The system will be used for a rf cavity experiment in Los Alamos and will serve as a prototype tuning power supply for future accelerators. 1 ref., 7 figs.

  16. Automating power supply checkout

    SciTech Connect

    Laster, J.; Bruno, D.; D'Ottavio, T.; Drozd, J.; Marr, G.; Mi, C.

    2011-03-28

    Power Supply checkout is a necessary, pre-beam, time-critical function. At odds are the desire to decrease the amount of time to perform the checkout while at the same time maximizing the number and types of checks that can be performed and analyzing the results quickly (in case any problems exist that must be addressed). Controls and Power Supply Group personnel have worked together to develop tools to accomplish these goals. Power Supply checkouts are now accomplished in a time-frame of hours rather than days, reducing the number of person-hours needed to accomplish the checkout and making the system available more quickly for beam development. The goal of the Collider-Accelerator Department (CAD) at Brookhaven National Laboratory is to provide experimenters with collisions of heavy-ions and polarized protons. The Relativistic Heavy-Ion Collider (RHIC) magnets are controlled by 100's of varying types of power supplies. There is a concentrated effort to perform routine maintenance on the supplies during shutdown periods. There is an effort at RHIC to streamline the time needed for system checkout in order to quickly arrive at a period of beam operations for RHIC. This time-critical period is when the checkout of the power supplies is performed as the RHIC ring becomes cold and the supplies are connected to their physical magnets. The checkout process is used to identify problems in voltage and current regulation by examining data signals related to each for problems in settling and regulation (ripple).

  17. Wind-powered asynchronous AC/DC/AC converter system. [for electric power supply regulation

    NASA Technical Reports Server (NTRS)

    Reitan, D. K.

    1973-01-01

    Two asynchronous ac/dc/ac systems are modelled that utilize wind power to drive a variable or constant hertz alternator. The first system employs a high power 60-hertz inverter tie to the large backup supply of the power company to either supplement them from wind energy, storage, or from a combination of both at a preset desired current; rectifier and inverter are identical and operate in either mode depending on the silicon control rectifier firing angle. The second system employs the same rectification but from a 60-hertz alternator arrangement; it provides mainly dc output, some sinusoidal 60-hertz from the wind bus and some high harmonic content 60-hertz from an 800-watt inverter.

  18. Power-Supply-Conditioning Circuit

    NASA Technical Reports Server (NTRS)

    Primas, L. E.; Loveland, R. C.

    1989-01-01

    Fluctuations of voltage suppressed in power supplies for precise radio-frequency circuits. Circuit suppresses both periodic and random deviations of dc supply voltage from desired steady level. Highly-stable feedback voltage regulator, conditioner intended in conjunction with conventional power-supply circuit to provide constant voltage to atomic frequency standard or other precise oscillator. Without conditioners, outputs of most commercial power supplies contain fluctuations causing unacceptably-large phase and amplitude modulation of precise oscillators.

  19. Single Event Transients in Voltage Regulators for FPGA Power Supply Applications

    NASA Technical Reports Server (NTRS)

    Poivey, Christian; Sanders, Anthony; Kim, Hak; Phan, Anthony; Forney, Jim; LaBel, Kenneth A.; Karsh, Jeremy; Pursley, Scott; Kleyner, Igor; Katz, Richard

    2006-01-01

    As with other bipolar analog devices, voltage regulators are known to be sensitive to single event transients (SET). In typical applications, large output capacitors are used to provide noise immunity. Therefore, since SET amplitude and duration are generally small, they are often of secondary importance due to this capacitance filtering. In low voltage applications, however, even small SET are a concern. Over-voltages may cause destructive conditions. Under-voltages may cause functional interrupts and may also trigger electrical latchup conditions. In addition, internal protection circuits which are affected by load as well as internal thermal effects can also be triggered from heavy ions, causing dropouts or shutdown ranging from milliseconds to seconds. In the case of FPGA power supplies applications, SETS are critical. For example, in the case of Actel FPGA RTAX family, core power supply voltage is 1.5V. Manufacturer specifies an absolute maximum rating of 1.6V and recommended operating conditions between 1.425V and 1.575V. Therefore, according to the manufacturer, any transient of amplitude greater than 75 mV can disrupt normal circuit functions, and overvoltages greater than 100 mV may damage the FPGA. We tested five low dropout voltage regulators for SET sensitivity under a large range of circuit application conditions.

  20. High voltage power supply

    NASA Technical Reports Server (NTRS)

    Ruitberg, A. P.; Young, K. M. (Inventor)

    1985-01-01

    A high voltage power supply is formed by three discrete circuits energized by a battery to provide a plurality of concurrent output signals floating at a high output voltage on the order of several tens of kilovolts. In the first two circuits, the regulator stages are pulse width modulated and include adjustable ressistances for varying the duty cycles of pulse trains provided to corresponding oscillator stages while the third regulator stage includes an adjustable resistance for varying the amplitude of a steady signal provided to a third oscillator stage. In the first circuit, the oscillator, formed by a constant current drive network and a tuned resonant network included a step up transformer, is coupled to a second step up transformer which, in turn, supplies an amplified sinusoidal signal to a parallel pair of complementary poled rectifying, voltage multiplier stages to generate the high output voltage.

  1. Switching power supply filter

    NASA Technical Reports Server (NTRS)

    Kumar, Prithvi R. (Inventor); Abare, Wayne (Inventor)

    1989-01-01

    A filter for a switching power supply. The filter includes a common mode inductor with coil configurations allowing differential mode current from a dc source to pass through but attenuating common mode noise from the power supply so that the noise does not reach the dc source. The invention also includes the use of feed through capacitors at the switching power supply input terminals to provide further high-frequency noise attenuation.

  2. Prognostic health monitoring in switch-mode power supplies with voltage regulation

    NASA Technical Reports Server (NTRS)

    Hofmeister, James P (Inventor); Judkins, Justin B (Inventor)

    2009-01-01

    The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.

  3. Power supply conditioning circuit

    NASA Technical Reports Server (NTRS)

    Primas, L. E.; Loveland, R.

    1987-01-01

    A power supply conditioning circuit that can reduce Periodic and Random Deviations (PARD) on the output voltages of dc power supplies to -150 dBV from dc to several KHz with no measurable periodic deviations is described. The PARD for a typical commercial low noise power supply is -74 dBV for frequencies above 20 Hz and is often much worse at frequencies below 20 Hz. The power supply conditioning circuit described here relies on the large differences in the dynamic impedances of a constant current diode and a zener diode to establish a dc voltage with low PARD. Power supplies with low PARD are especially important in circuitry involving ultrastable frequencies for the Deep Space Network.

  4. Penumatic-power supply

    NASA Technical Reports Server (NTRS)

    Kramer, R. C.

    1981-01-01

    Portable compressed air supply has two or more outputs at pressures from 20 to 100 psi. Applications include operating production equipment, spraying paint and lubricants, and pressurizing refrigeration systems. Supply filters air from standard high-pressure line, reduces it to working pressure, and adds lubricant when required. Regulator supplies low-pressure air to output channels. On channel lines, vernier-control valves select output pressures.

  5. Lifting BLS Power Supplies

    SciTech Connect

    Sarychev, Michael

    2007-08-01

    This note describes BLS power supplies lifting techniques and provides stress calculations for lifting plate and handles bolts. BLS power supply weight is about 120 Lbs, with the center of gravity shifted toward the right front side. A lifting plate is used to attach a power supply to a crane or a hoist. Stress calculations show that safety factors for lifting plate are 12.9 (vs. 5 required) for ultimate stress and 5.7 (vs. 3 required) for yield stress. Safety factor for shackle bolt thread shear load is 37, and safety factor for bolts that attach handles is 12.8.

  6. Improved Programmable High-Voltage Power Supply

    NASA Technical Reports Server (NTRS)

    Castell, Karen; Rutberg, Arthur

    1994-01-01

    Improved dc-to-dc converter functions as programmable high-voltage power supply with low-power-dissipation voltage regulator on high-voltage side. Design of power supply overcomes deficiencies of older designs. Voltage regulation with low power dissipation provided on high-voltage side.

  7. Mobile Uninterruptible Power Supply

    NASA Technical Reports Server (NTRS)

    Mears, Robert L.

    1990-01-01

    Proposed mobile unit provides 20 kVA of uninterruptible power. Used with mobile secondary power-distribution centers to provide power to test equipment with minimal cabling, hazards, and obstacles. Wheeled close to test equipment and system being tested so only short cable connections needed. Quickly moved and set up in new location. Uninterruptible power supply intended for tests which data lost or equipment damaged during even transient power failure.

  8. APS power supply controls

    SciTech Connect

    Saunders, C.W.; Despe, O.D.

    1994-03-31

    The purpose of this document is to provide comprehensive coverage of the APS power supply control design. This includes application software, embedded controller software, networks, and hardware. The basic components will be introduced first, followed by the requirements driving the overall design. Subsequent sections will address each component of the design one by one. Latter sections will address specific applications.

  9. Discontinuous Mode Power Supply

    NASA Technical Reports Server (NTRS)

    Lagadinos, John; Poulos, Ethel

    2012-01-01

    A document discusses the changes made to a standard push-pull inverter circuit to avoid saturation effects in the main inverter power supply. Typically, in a standard push-pull arrangement, the unsymmetrical primary excitation causes variations in the volt second integral of each half of the excitation cycle that could lead to the establishment of DC flux density in the magnetic core, which could eventually cause saturation of the main inverter transformer. The relocation of the filter reactor normally placed across the output of the power supply solves this problem. The filter reactor was placed in series with the primary circuit of the main inverter transformer, and is presented as impedance against the sudden changes on the input current. The reactor averaged the input current in the primary circuit, avoiding saturation of the main inverter transformer. Since the implementation of the described change, the above problem has not reoccurred, and failures in the main power transistors have been avoided.

  10. Power Supplies for Precooler Ring

    SciTech Connect

    Fuja, Raymond; Praeg, Walter

    1980-12-12

    Eight power supplies will energize the antiproton Precooler ring. there will be two series connected supplies per quadrant. These supplies will power 32 dipole and 19 quadrupole magnets. The resistance and inductance per quadrant is R = 1.4045 Ohms and L = 0.466. Each powr supply will have 12-phase series bridge rectifiers and will be energized from the 480 V 3-phase grid. The total of eight power supplies are numbered IA, IIA, IIIA, IVA, and IB, IIB, IIIB, and IVB. Each quadrant will contain one A and one B supply. A block diagram of the Precooler ring with its power supplies is shown in Figure 1.

  11. Simplified power supplies for ion thrusters

    NASA Technical Reports Server (NTRS)

    Gruber, R. P.

    1981-01-01

    The initial development and demonstration of power supplies with an order of magnitude reduction in parts count, leading to increased reliability at lower weight, while still maintaining thrust system performance are discussed. Two new self-regulating keeper power supply circuits were developed and tested. One supply comprises 14 parts and uses an input voltage range of 18 to 36 volts, the other operates from 200 to 400 volts and requires 22 components. A technique for controlling heater power is also demonstrated.

  12. Switching power supply

    DOEpatents

    Mihalka, A.M.

    1984-06-05

    The invention is a repratable capacitor charging, switching power supply. A ferrite transformer steps up a dc input. The transformer primary is in a full bridge configuration utilizing power MOSFETs as the bridge switches. The transformer secondary is fed into a high voltage, full wave rectifier whose output is connected directly to the energy storage capacitor. The transformer is designed to provide adequate leakage inductance to limit capacitor current. The MOSFETs are switched to the variable frequency from 20 to 50 kHz to charge a capacitor from 0.6 kV. The peak current in a transformer primary and secondary is controlled by increasing the pulse width as the capacitor charges. A digital ripple counter counts pulses and after a preselected desired number is reached an up-counter is clocked.

  13. Power Supply Unit

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The Cuk DC to DC Switching Converter was developed by Caltech Professors, Slobodan Cuk and R. D. Middlebrook. The converter changes unsuitable dc voltage into one or more voltages suitable for powering electronic equipment; it can also be used in converting dc current to ac and vice versa. It was named one of the 100 most significant technical advances of 1979. The Cuk converter is more efficient than previous conversion devices, simpler, smaller, lighter, cheaper and highly reliable. The first application of the technology is in the Compucorp 685 word/data processor, manufactured by Compucorp. NASA waived title rights; Caltech granted exclusive license to the inventors, who in turn, transferred their rights to a company they founded called TESLA Company, which sublicenses the converter design and related technology to companies making power supplies for use in their own products.

  14. High voltage DC power supply

    DOEpatents

    Droege, T.F.

    1989-12-19

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

  15. High voltage DC power supply

    DOEpatents

    Droege, Thomas F.

    1989-01-01

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

  16. Ignitor Electrical Power Supply System

    NASA Astrophysics Data System (ADS)

    Coletti, Alberto; Coletti, Roberto; Costa, Pietro; Maffia, Giuseppe; Ramogida, Giuseppe; Roccella, Massimo; Santinelli, Maurizio; Starace, Fabio

    2004-11-01

    An iterative optimization process to reduce the total installed electrical power required for Ignitor has been performed, bringing its value down to about 70% of that estimated originally. Ignitor is planned to be installed within the 400 kV Station of Rondissone (near Turin). The required electrical power (1000 MVA / 320 MVAr, including 480 MVAr locally compensated through static system, SVC) has been demonstrated by the technical authority GRTN to be compatible with the Grid capability. The magnet systems of Ignitor are supplied by means of a set of 14, 12 pulse, current regulated, sequentially or internal freewheeling controlled, fully static power amplifier units which are installed inside standard, outdoor-kind containers, located near to the related step-down transformers. Each container can house up to 100 MW, 2x12 pulse power amplifier units. The connection between the power amplifiers and the machine is performed by means of coaxial, outdoor-kind, segregated bus-bars. These choices make the whole power supply system as flexible as possible in terms of the overall layout of the Ignitor plant.

  17. Reliability Estimates for Power Supplies

    SciTech Connect

    Lee C. Cadwallader; Peter I. Petersen

    2005-09-01

    Failure rates for large power supplies at a fusion facility are critical knowledge needed to estimate availability of the facility or to set priorties for repairs and spare components. A study of the "failure to operate on demand" and "failure to continue to operate" failure rates has been performed for the large power supplies at DIII-D, which provide power to the magnet coils, the neutral beam injectors, the electron cyclotron heating systems, and the fast wave systems. When one of the power supplies fails to operate, the research program has to be either temporarily changed or halted. If one of the power supplies for the toroidal or ohmic heating coils fails, the operations have to be suspended or the research is continued at de-rated parameters until a repair is completed. If one of the power supplies used in the auxiliary plasma heating systems fails the research is often temporarily changed until a repair is completed. The power supplies are operated remotely and repairs are only performed when the power supplies are off line, so that failure of a power supply does not cause any risk to personnel. The DIII-D Trouble Report database was used to determine the number of power supply faults (over 1,700 reports), and tokamak annual operations data supplied the number of shots, operating times, and power supply usage for the DIII-D operating campaigns between mid-1987 and 2004. Where possible, these power supply failure rates from DIII-D will be compared to similar work that has been performed for the Joint European Torus equipment. These independent data sets support validation of the fusion-specific failure rate values.

  18. Standardized multiple output power supply

    NASA Technical Reports Server (NTRS)

    Ragusa, E. V.

    1975-01-01

    A comprehensive program to develop a prototype model of a standardized multiple output power supply for use in space flight applications is described. The prototype unit was tested and evaluated to assure that the design would provide near optimum performance for the planned application. The prototype design used a dc-to-dc converter incorporating reqenerative current feedback with a time-ratio controlled duty cycle to achieve high efficiency over a wide variation of input voltage and output loads. The packaging concept uses a mainframe capable of accommodating up to four inverter/regulator modules with one common input filter and housekeeping module. Each inverter/regulator module provides a maximum of 100 watts or 10 amperes. Each module is adaptable to operate at any voltage between 4.0 volts and 108 volts. The prototype unit contains +5, + or - 15 and +28 volt modules.

  19. Simplified power supplies for ion thrusters

    NASA Technical Reports Server (NTRS)

    Gruber, R. P.

    1981-01-01

    A program addressing less complex and potentially lower cost ion thruster systems has been started at the NASA Lewis Research Center. This paper discusses the initial development and demonstration of power supplies with an order of magnitude reduction in parts count, leading to increased reliability at lower weight, while still maintaining thrust system performance. Two new self-regulating keeper power supply circuits were developed and tested. One supply comprises 14 parts and uses an input voltage range of 18 to 36 volts, the other operates from 200 to 400 volts and requires 22 components. A new technique for controlling heater power is also demonstrated.

  20. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    DOEpatents

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  1. Multiple resonant railgun power supply

    SciTech Connect

    Honig, E.M.; Nunnally, W.C.

    1985-06-19

    A multiple repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. A plurality of serially connected paired parallel rails are powered by similar power supplies. Each supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles. The multiple serial operation permits relatively small energy components to deliver overall relatively large amounts of energy to the projectiles being propelled.

  2. Multiple resonant railgun power supply

    SciTech Connect

    Honig, Emanuel M.; Nunnally, William C.

    1988-01-01

    A multiple repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. A plurality of serially connected paired parallel rails are powered by similar power supplies. Each supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles. The multiple serial operation permits relatively small energy components to deliver overall relatively large amounts of energy to the projectiles being propelled.

  3. Repetitive resonant railgun power supply

    DOEpatents

    Honig, E.M.; Nunnally, W.C.

    1985-06-19

    A repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. The supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles.

  4. Repetitive resonant railgun power supply

    DOEpatents

    Honig, Emanuel M.; Nunnally, William C.

    1988-01-01

    A repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. The supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles.

  5. ORION downconverter and power supply

    NASA Technical Reports Server (NTRS)

    Nishimura, H. G.

    1982-01-01

    The receiver subsystem supplies the front end assembly (downconverter) and power supply for the ORION Mobile Station. These assemblies are designed to withstand severe environmental conditions. The mechanical, electronic, environmental and maintenance design considerations encountered during the design phase of this project are discussed. The two channel S/X downconverter has a 400 MHz bandwidth channel. Phase stability of 2 and 7 deg at S- and X-bands, respectively, is achieved with a temperature stabilized first local oscillator.

  6. A novel flattop current regulated energy discharge type pulsed power supply and magnet yielding 4. 4 kGauss-meter for 6 milliseconds

    SciTech Connect

    Visser, A.T.

    1989-07-01

    Most energy discharge power supplies obtain their bursts of power from the energy stored in charged capacitors when it is suddenly released into a load. This note describes the design of a similar small 800 Joules energy discharge type power supply and magnet. The magnet gap is 2 in.{times}2 in.{times}25-1/2 in. long and produces about 4.4 kGauss-meters at a rate of 12 pulses per minute. Each pulse is current regulated at the top for a duration of 6 msec. and varies less than 0.6% of set value. Current regulation at flattop is obtained by switching a resistor in and out of the discharge circuit with an IGBT at a rate of about 5 kHz. Most energy discharge systems produce half sine wave pulses, and current regulation is obtained by controlling the charge voltage at the energy storage capacitor, resulting only in a controlled peak current value of the half sine wave pulse. The current value at the top changes substantially during 6 msec. depending on the operating frequency.

  7. Fixed costs of providing ancillary services from power plants: Reactive supply and voltage control, regulation and frequency response, operating reserve--spinning. Final report

    SciTech Connect

    Boyle, R.; Kure-Jensen, J.

    1998-12-01

    This report describes methodologies to determine the fixed costs for a steam cycle generating unit to participate in Reactive Supply and Voltage Control (RS-VC), Regulation and Frequency Response (RFR), and Operating Reserve-Spinning (ORS) services. It is intended for use by a Generator of electricity who is planning to offer these ancillary services in a competitive market. The methodology is based on common steam power plant engineering and economic principles. Reactive supply and voltage control provides reactive supply through changes to generator reactive output to maintain acceptable transmission system voltages and facilitate electricity transfers and provides the ability to continually adjust transmission system voltage in response to system changes. Regulation and frequency response service include all rapid load changes whether their purpose is to meet the instantaneous load demand, to balance control area supply resources with load, or to maintain frequency. Spinning reserve is provided by generating units that are on-line and loaded at less than maximum output. They are available to serve load immediately in an unexpected contingency such as an unplanned outage of a generating unit.

  8. E-beam high voltage switching power supply

    DOEpatents

    Shimer, Daniel W.; Lange, Arnold C.

    1996-01-01

    A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  9. E-beam high voltage switching power supply

    DOEpatents

    Shimer, D.W.; Lange, A.C.

    1996-10-15

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

  10. 46 CFR 113.25-6 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... reference; see 46 CFR 110.10-1), Regulation II-1/42 or II-1/43, as applicable. ... 46 Shipping 4 2012-10-01 2012-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power...

  11. 46 CFR 113.25-6 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... reference; see 46 CFR 110.10-1), Regulation II-1/42 or II-1/43, as applicable. ... 46 Shipping 4 2014-10-01 2014-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power...

  12. 46 CFR 113.25-6 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... reference; see 46 CFR 110.10-1), Regulation II-1/42 or II-1/43, as applicable. ... 46 Shipping 4 2011-10-01 2011-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power...

  13. 46 CFR 113.25-6 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reference; see 46 CFR 110.10-1), Regulation II-1/42 or II-1/43, as applicable. ... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power...

  14. 46 CFR 113.25-6 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... reference; see 46 CFR 110.10-1), Regulation II-1/42 or II-1/43, as applicable. ... 46 Shipping 4 2013-10-01 2013-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST... SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power...

  15. Mars sample return power supply

    NASA Technical Reports Server (NTRS)

    Hoang, Don; Ludwigs, Sharon; Schmitz, Paul; Wright, John

    1988-01-01

    A power supply is designed for a vehicle able to operate on the surface of Mars for a period of 5 to 10 years. This vehicle will be used for sample and data collection. The design is based on the assumption that the vehicle will be unmanned. Also, there will be no means by which components could be repaired or replaced while on the Martian surface. A consequence of this is that all equipment must meet high standards of reliability and, if possible, redundancy. Power will be supplied to the vehicle by means of a General Purpose Heat Source capable of producing a minimum of 7 kW of thermal power. The heat generated from the General Purpose Heat Source will be transferred to a Stirling engine via hot side heat pipes. The Stirling engine will then convert this heat into 2 kW of electrical power. Cold side heat pipes will be used to carry away waste heat, which will be released to the Martian environment via radiators connected to the end of the cold side heat pipes.

  16. Switching System for Redundant Power Supplies

    NASA Technical Reports Server (NTRS)

    Bradford, M.; Grant, R.; Parkinson, G.

    1986-01-01

    Load-transfer unit connects airborne computer to standby power supply in case primary supply fails. Concept adaptable to systems in which power interruptions cannot be tolerated; for example, computers with volatile memories, safety equipment, and precise timers. Load-transfer unit monitors voltages and load current. Microprocessor controls transistor switches that connect load to whichever power supply has highest priority and correct voltage.

  17. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  18. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. Link to an amendment published at 78 FR 73990, Dec. 9, 2013. (a) The power supply to the...

  19. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  20. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  1. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  2. 49 CFR 393.23 - Power supply for lamps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Power supply for lamps. 393.23 Section 393.23 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply...

  3. Solar power supply for spacecraft

    SciTech Connect

    Henesian, A.

    1981-12-15

    A solar power supply for a spacecraft comprises an array of semiconductor devices for photovoltaic conversion of sunlight into electrical energy. Each semiconductor device is secured by a substantially stress-free electrically conductive joint to a flexible dielectric substrate that can be folded into a compact stowage configuration or opened into an elongate operational configuration. The stress-free joint is formed by securing an electrical terminal of the semiconductor device to a stress-relieving electrical conductor that is affixed to the substrate. Preferably, the stress-relieving conductor is a metallic wire mesh, a peripheral portion of which is adhesively bonded to the substrate circumjacent an aperture in the substrate. A pattern of metallic traces formed on the substrate provides a circuit for connecting the wire mesh to connectors for coupling electrical power generated by the array of semiconductor devices to an electrical load on the spacecraft.

  4. A new bipolar Qtrim power supply system

    SciTech Connect

    Mi, C.; Bruno, D.; Drozd, J.; Nolan, T.; Orsatti, F.; Heppener, G.; Di Lieto, A.; Schultheiss, C.; Samms, T.; Zapasek, R.; Sandberg, J.

    2015-05-03

    This year marks the 15th run of RHIC (Relativistic Heavy Ion Collider) operations. The reliability of superconducting magnet power supplies is one of the essential factors in the entire accelerator complex. Besides maintaining existing power supplies and their associated equipment, newly designed systems are also required based on the physicist’s latest requirements. A bipolar power supply was required for this year’s main quadruple trim power supply. This paper will explain the design, prototype, testing, installation and operation of this recently installed power supply system.

  5. Power Supply For 25-Watt Arc Lamp

    NASA Technical Reports Server (NTRS)

    Leighty, B. D.

    1985-01-01

    Dual-voltage circuitry both strikes and maintains arc. New power supply designed (and several units already in use) that replaces relay/choke combination with solid-state starter. New power supply consists of two main sections. First section (low voltage power supply section) is 84-volt directcurrent supply. Second section (high-voltage starter circuit) is CockroftWalton voltage multiplier. Used as light sources for schlieren, shadowgraph, and other flow-visualization techniques.

  6. Modular high voltage power supply for chemical analysis

    DOEpatents

    Stamps, James F.; Yee, Daniel D.

    2010-05-04

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  7. Modular high voltage power supply for chemical analysis

    DOEpatents

    Stamps, James F.; Yee, Daniel D.

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  8. Modular high voltage power supply for chemical analysis

    DOEpatents

    Stamps, James F.; Yee, Daniel D.

    2007-01-09

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  9. Uninterruptible power supply (UPS) systems

    SciTech Connect

    1997-04-01

    Use of this purchase specification is not mandatory. User should review the document and determine if it meets the user`s purpose. This document contains a fill-in-the-blanks guide specification for the procurement of uninterruptible power supply (UPS) systems greater than 10 kVA, organized as follows: Parts 1 through 7--technical requirements; Appendix A--technical requirements to be included in the proposal; Appendix B--UPS system data sheets to be completed by each bidder (Seller) and submitted with the proposal; Appendix C--general guidelines giving the specifier parameters for selecting a UPS system; it should be read before preparing an actual specification, and is not attached to the specification; Attachment 1--sketches prepared by the purchaser (Owner); Attachment 2--sample title page.

  10. Advanced Accessory Power Supply Topologies

    SciTech Connect

    Marlino, L.D.

    2010-06-15

    This Cooperative Research and Development Agreement (CRADA) began December 8, 2000 and ended September 30, 2009. The total funding provided by the Participant (General Motors Advanced Technology Vehicles [GM]) during the course of the CRADA totaled $1.2M enabling the Contractor (UT-Battelle, LLC [Oak Ridge National Laboratory, a.k.a. ORNL]) to contribute significantly to the joint project. The initial task was to work with GM on the feasibility of developing their conceptual approach of modifying major components of the existing traction inverter/drive to develop low cost, robust, accessory power. Two alternate methods for implementation were suggested by ORNL and both were proven successful through simulations and then extensive testing of prototypes designed and fabricated during the project. This validated the GM overall concept. Moreover, three joint U.S. patents were issued and subsequently licensed by GM. After successfully fulfilling the initial objective, the direction and duration of the CRADA was modified and GM provided funding for two additional tasks. The first new task was to provide the basic development for implementing a cascaded inverter technology into hybrid vehicles (including plug-in hybrid, fuel cell, and electric). The second new task was to continue the basic development for implementing inverter and converter topologies and new technology assessments for hybrid vehicle applications. Additionally, this task was to address the use of high temperature components in drive systems. Under this CRADA, ORNL conducted further research based on GM’s idea of using the motor magnetic core and windings to produce bidirectional accessory power supply that is nongalvanically coupled to the terminals of the high voltage dc-link battery of hybrid vehicles. In order not to interfere with the motor’s torque, ORNL suggested to use the zero-sequence, highfrequency harmonics carried by the main fundamental motor current for producing the accessory power

  11. Development of dielectric barrier discharging power supply

    NASA Astrophysics Data System (ADS)

    Gao, Yinghui; Liu, Kun; Fu, Rongyao; Sun, Yaohong; Yan, Ping

    2015-11-01

    Due to the demand of a dielectric barrier discharge power supply, a high voltage and high frequency AC power supply was designed and implemented. Its output voltage is standard or approximate standard sine waveform with the frequency range of 1 kHz to 50 kHz. The output voltage and output frequency can be adjusted individually. The maximum output power of the power supply is 2 kW. It can be operated through local or remote control. The power supply has been used in the dielectric barrier discharging research under different conditions.

  12. ATF2 High Availability Power Supplies

    SciTech Connect

    Bellomo, A; Lira, C.de; Lam, B.; MacNair, D.; White, G.; /SLAC

    2008-06-27

    ATF2 is an accelerator test facility modeled after the final focus beamline envisioned for the ILC. By the end of 2008, KEK plans to commission the ATF2 [1]. SLAC and OCEM collaborated on the design of 38 power systems for beamline magnets. The systems range in output power from 1.5 kW to 6 kW. Since high availability is essential for the success of the ILC, Collaborators employed an N+1 modular approach, allowing for redundancy and the use of a single power module rating. This approach increases the availability of the power systems. Common power modules reduces inventory and eases maintenance. Current stability requirements are as tight as 10 ppm. A novel, SLAC designed 20-bit Ethernet Power Supply Controller provides the required precision current regulation. In this paper, Collaborators present the power system design, the expected reliability, fault immunity features, and the methods for satisfying the control and monitoring challenges. Presented are test results and the status of the power systems.

  13. Intrinsically safe 5-V, 4-A rechargeable power supply

    NASA Astrophysics Data System (ADS)

    Sammarco, John J.

    The U.S. Bureau of Mines has developed a regulated, intrinsically safe, rechargeable power supply for portable electronic equipment for underground use. The regulated output is ideal for microprocessor power requirements and is suited for operation in hazardous environments. Two rechargeable, sealed batteries are contained within the power supply. Provisions are made to use an external source of power if these batteries fail. Provisions are also made to charge these internal batteries when needed. The circuit is composed of three main circuits: the main regulator circuit, the input protection circuit, and the output protection circuit. The main regulator circuit provides remote voltage sensing, current sensing, fault monitoring, and internal thermal protection. The input protection circuit checks for excessive input current and low battery conditions. The output protection circuit contains two overvoltage detection devices. Schematics, a parts list, and a calibration procedure are provided in the report to enable readers to fabricate the power supply.

  14. 49 CFR 236.516 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power...

  15. 46 CFR 169.688 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Power supply. 169.688 Section 169.688 Shipping COAST... Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.688 Power supply. (a) The... provide electric power for any vital system listed in § 169.642 of this subchapter, at least...

  16. 46 CFR 169.688 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Power supply. 169.688 Section 169.688 Shipping COAST... Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.688 Power supply. (a) The... provide electric power for any vital system listed in § 169.642 of this subchapter, at least...

  17. 49 CFR 236.516 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power...

  18. 49 CFR 236.516 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power...

  19. 46 CFR 169.688 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Power supply. 169.688 Section 169.688 Shipping COAST... Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.688 Power supply. (a) The... provide electric power for any vital system listed in § 169.642 of this subchapter, at least...

  20. 49 CFR 236.516 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power...

  1. 46 CFR 169.688 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Power supply. 169.688 Section 169.688 Shipping COAST... Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.688 Power supply. (a) The... provide electric power for any vital system listed in § 169.642 of this subchapter, at least...

  2. 46 CFR 169.688 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Power supply. 169.688 Section 169.688 Shipping COAST... Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.688 Power supply. (a) The... provide electric power for any vital system listed in § 169.642 of this subchapter, at least...

  3. 49 CFR 236.516 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power...

  4. Shock-activated electrochemical power supplies

    DOEpatents

    Benedick, W.B.; Graham, R.A.; Morosin, B.

    1987-04-20

    A shock-activated electrochemical power supply is provided which is initiated extremely rapidly and which has a long shelf life. Electrochemical power supplies of this invention are initiated much faster than conventional thermal batteries. Power supplies of this invention comprise an inactive electrolyte and means for generating a high-pressure shock wave such that the shock wave is propagated through the electrolyte rendering the electrolyte electrochemically active. 2 figs.

  5. Shock-activated electrochemical power supplies

    DOEpatents

    Benedick, William B.; Graham, Robert A.; Morosin, Bruno

    1988-01-01

    A shock-activated electrochemical power supply is provided which is initiated extremely rapidly and which has a long shelf life. Electrochemical power supplies of this invention are initiated much faster than conventional thermal batteries. Power supplies of this invention comprise an inactive electrolyte and means for generating a high-pressure shock wave such that the shock wave is propagated through the electrolytes rendering the electrolyte electrochemically active.

  6. Shock-activated electrochemical power supplies

    DOEpatents

    Benedick, W.B.; Graham, R.A.; Morosin, B.

    1988-11-08

    A shock-activated electrochemical power supply is provided which is initiated extremely rapidly and which has a long shelf life. Electrochemical power supplies of this invention are initiated much faster than conventional thermal batteries. Power supplies of this invention comprise an inactive electrolyte and means for generating a high-pressure shock wave such that the shock wave is propagated through the electrolytes rendering the electrolyte electrochemically active. 2 figs.

  7. HIRFL-CSR power supply system

    NASA Astrophysics Data System (ADS)

    Gao, Daqing; Zhou, Zhongzu; Chen, Youxin; Wu, Rong; Shangguan, Jingbin; Bai, Zhen

    2001-12-01

    There are more than 200 power supplies will be employed in CSR power supply system. These power supplies provide DC and pulsed exciting current for all magnets in main ring (CSRm), experiment ring (CSRe), injection line of CSRm and RIB line. Six small-scale prototypes have been designed and made before formal manufacture. One thyristor rectifier pulsed converter was delivered to Lanzhou in January and all measurement has been finished in April. The result is satisfied.

  8. Shunt regulation electric power system

    NASA Technical Reports Server (NTRS)

    Wright, W. H.; Bless, J. J. (Inventor)

    1971-01-01

    A regulated electric power system having load and return bus lines is described. A plurality of solar cells interconnected in a power supplying relationship and having a power shunt tap point electrically spaced from the bus lines is provided. A power dissipator is connected to the shunt tap point and provides for a controllable dissipation of excess energy supplied by the solar cells. A dissipation driver is coupled to the power dissipator and controls its conductance and dissipation and is also connected to the solar cells in a power taping relationship to derive operating power therefrom. An error signal generator is coupled to the load bus and to a reference signal generator to provide an error output signal which is representative of the difference between the electric parameters existing at the load bus and the reference signal generator. An error amplifier is coupled to the error signal generator and the dissipation driver to provide the driver with controlling signals.

  9. Variable load automatically tests dc power supplies

    NASA Technical Reports Server (NTRS)

    Burke, H. C., Jr.; Sullivan, R. M.

    1965-01-01

    Continuously variable load automatically tests dc power supplies over an extended current range. External meters monitor current and voltage, and multipliers at the outputs facilitate plotting the power curve of the unit.

  10. CONCEPTUAL DESIGN STUDY OF HORN POWER SUPPLY.

    SciTech Connect

    ZHANG,W.; SANDBERG,J.; WENG,W.T.

    2003-06-16

    A 250 kA pulsed power supply is required for the focusing horn of the proposed Brookhaven AGS Super Neutrino Beam Facility for long baseline neutrino oscillation experiment. It is expected to pulse at 2.5 Hz repetition rate. A preliminary study is being conducted to explore the key issues associated with the power supply system design. Advanced technologies used in similar systems as well as new ideas are being examined, simulated and evaluated. This power supply will be a very high stored energy, high average power, and high peak power system.

  11. Upgrading the TFTR Transrex Power Supplies

    SciTech Connect

    J. E. Lawson, R. Marsala, S. Ramakrishnan, X. Zhao, P. Sichta

    2009-05-29

    In order to provide improved and expanded experimental capabilities, the existing Transrex power supplies at PPPL are to be upgraded and modernized. Each of the 39 power supplies consists of two six pulse silicon controlled rectifier sections forming a twelve pulse power supply. The first modification is to split each supply into two independent six pulse supplies by replacing the existing obsolete twelve pulse firing generator with two commercially available six pulse firing generators. The second change replaces the existing control link with a faster system, with greater capacity, which will allow for independent control of all 78 power supply sections. The third change replaces the existing Computer Automated Measurement and Control (CAMAC) based fault detector with an Experimental Physics and Industrial Control System (EPICS) compatible unit, eliminating the obsolete CAMAC modules. Finally the remaining relay logic and interfaces to the "Hardwired Control System" will be replaces with a Programmable Logic Controller (PLC).

  12. 47 CFR 80.1015 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Power supply. 80.1015 Section 80.1015 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Radiotelephone Installations Required by the Bridge-to-Bridge Act § 80.1015 Power supply. (a) There must be readily...

  13. 47 CFR 80.1015 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Power supply. 80.1015 Section 80.1015 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Radiotelephone Installations Required by the Bridge-to-Bridge Act § 80.1015 Power supply. (a) There must be readily...

  14. 47 CFR 80.1015 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Power supply. 80.1015 Section 80.1015 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Radiotelephone Installations Required by the Bridge-to-Bridge Act § 80.1015 Power supply. (a) There must be readily...

  15. 47 CFR 80.1015 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Power supply. 80.1015 Section 80.1015 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Radiotelephone Installations Required by the Bridge-to-Bridge Act § 80.1015 Power supply. (a) There must be readily...

  16. Neutrino horn power supply operational experience

    SciTech Connect

    Stillman, P.; Sandberg, J.; Carroll, A.S.; Leonhardt, W.; Monaghan, R.; Pearson, C.; Pendzich, A.; Ryan, G.; Sims, W.P.; Smith, G.A.

    1987-01-01

    The operational experiences required to run the 300 kA pulsed power supply at Brookhaven National Laboratory are given. Various interlocks and monitoring circuits are described and the impact on system reliability are discussed. The initial conditioning process of the power supply during startup is described.

  17. Thermal control of power supplies with electronic packaging techniques

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The analysis, design, and development work to reduce the weight and size of a standard modular power supply with a 350 watt output was summarized. By integrating low cost commercial heat pipes in the redesign of this power supply, weight was reduced by 30% from that of the previous design. The temperature was also appreciably reduced, increasing the environmental capability of the unit. A demonstration unit with a 100 watt output and a 15 volt regulator module, plus simulated output modules, was built and tested to evaluate the thermal performance of the redesigned power supply.

  18. High performance magnet power supply optimization

    SciTech Connect

    Jackson, L.T.

    1988-01-01

    The power supply system for the joint LBL--SLAC proposed accelerator PEP provides the opportunity to take a fresh look at the current techniques employed for controlling large amounts of dc power and the possibility of using a new one. A basic requirement of +- 100 ppM regulation is placed on the guide field of the bending magnets and quadrupoles placed around the 2200 meter circumference of the accelerator. The optimization questions to be answered by this paper are threefold: Can a firing circuit be designed to reduce the combined effects of the harmonics and line voltage combined effects of the harmonics and line voltage unbalance to less than 100 ppM in the magnet field. Given the ambiguity of the previous statement, is the addition of a transistor bank to a nominal SCR controlled system the way to go or should one opt for an SCR chopper system running at 1 KHz where multiple supplies are fed from one large dc bus and the cost--performance evaluation of the three possible systems.

  19. High Power Amplifier and Power Supply

    NASA Technical Reports Server (NTRS)

    Duong, Johnny; Stride, Scot; Harvey, Wayne; Haque, Inam; Packard, Newton; Ng, Quintin; Ispirian, Julie Y.; Waian, Christopher; Janes, Drew

    2008-01-01

    A document discusses the creation of a high-voltage power supply (HVPS) that is able to contain voltages up to -20 kV, keep electrical field strengths to below 200 V/mil (approximately equal to 7.87 kV/mm), and can provide a 200-nanosecond rise/fall time focus modulator swinging between cathode potential of 16.3 kV and -19.3 kV. This HVPS can protect the 95-GHz, pulsed extended interaction klystron (EIK) from arcs/discharges from all sources, including those from within the EIK fs vacuum envelope. This innovation has a multi-winding pulse transformer design, which uses new winding techniques to provide the same delays and rise/fall times (less than 10 nanoseconds) at different potential levels ranging from -20 kV to -16 kV. Another feature involves a high-voltage printed-wiring board that was corona-free at -20 kV DC with a 3- kV AC swing. The corona-free multilayer high-voltage board is used to simulate fields of less than 200 V/mil (approximately equal to 7.87 kV/mm) at 20 kV DC. Drive techniques for the modulator FETs (field-effect transistors) (four to 10 in a series) were created to change states (3,000-V swing) without abrupt steps, while still maintaining required delays and transition times. The packing scheme includes a potting mold to house a ten-stage modulator in the space that, in the past, only housed a four-stage modulator. Problems keeping heat down were solved using aluminum oxide substrate in the high-voltage section to limit temperature rise to less than 10 while withstanding -20 kV DC voltage and remaining corona-free.

  20. A crowbarless power supply for klystrons.

    PubMed

    Kozu, H; Jumonji, Y; Yamazaki, C; Shoji, Y; Hashimoto, S; Ando, A

    1998-05-01

    A new crowbarless power supply is to be installed at the New SUBARU storage ring. A high-power switching inverter unit eliminates the need for expensive and unstable crowbar circuits for the klystron power supply. It also realizes a very small voltage ripple in the low-frequency region. This is an important characteristic, especially in a quasi-isochronous storage ring such as New SUBARU. PMID:15263515

  1. OVERVIEW OF THE AGS COLD SNAKE POWER SUPPLIES AND THE NEW RHIC SEXTUPOLE POWER SUPPLIES

    SciTech Connect

    BRUNO,D.; GANETIS, G.; SANDBERG, J.; LOUIE, W.

    2007-06-25

    The two rings in the Relativistic Heavy Ion Collider (RHIC) were originally constructed with 24 sextupole power supplies, 12 for each ring. Before the start of Run 7, 24 new sextupole power supplies were installed, 12 for each ring. Individual sextupole power supplies are now each connected to six sextupole magnets. A superconducting snake magnet and power supplies were installed in the Alternating Gradient Synchrotron (AGS) and commissioned during RHIC Run 5, and used operationally in RHIC Run 6. The power supply technology, connections, control systems and interfacing with the Quench Protection system for both these systems will be presented.

  2. Digitally Controlled High Availability Power Supply

    SciTech Connect

    MacNair, David; /SLAC

    2008-09-25

    This paper reports the design and test results on novel topology, high-efficiency, and low operating temperature, 1,320-watt power modules for high availability power supplies. The modules permit parallel operation for N+1 redundancy with hot swap capability. An embedded DSP provides intelligent start-up and shutdown, output regulation, general control and fault detection. PWM modules in the DSP drive the FET switches at 20 to 100 kHz. The DSP also ensures current sharing between modules, synchronized switching, and soft start up for hot swapping. The module voltage and current have dedicated ADCs (>200 kS/sec) to provide pulse-by-pulse output control. A Dual CAN bus interface provides for low cost redundant control paths. Over-rated module components provide high reliability and high efficiency at full load. Low on-resistance FETs replace conventional diodes in the buck regulator. Saturable inductors limit the FET reverse diode current during switching. The modules operate in a two-quadrant mode, allowing bipolar output from complimentary module groups. Controllable, low resistance FETs at the input and output provide fault isolation and allow module hot swapping.

  3. Intrinsically safe 5-V, 4-A rechargeable power supply

    SciTech Connect

    Sammarco, J.J.

    1989-01-01

    The author reports on a regulated, intrinsically safe, rechargeable power supply for portable electronic equipment for underground use. The regulated output is ideal for microprocessor power requirements and is suited for operation in hazardous environments. Two rechargeable, sealed batteries are contained within the power supply. Provisions are made to use an external source of power if these batteries fail. Provisions are also made to charge these internal batteries when needed. The circuit is composed of three main circuits: the main regulator circuit, the input protection circuit, and the output protection circuit. The main regulator circuit provides remote voltage sensing, current sensing, fault monitoring, and internal thermal protection. The input protection circuit checks for excessive input current and low battery conditions. The output protection circuit contains two overvoltage detection devices. Schematics, a parts list, and a calibration procedure are provided.

  4. Control units for APS power supplies

    SciTech Connect

    Despe, O.D.; Saunders, C.; McGhee, D.G.

    1993-07-01

    The Advanced Photon Source (APS) accelerator facility is made up of five major subsystems in addition to the linac: the positron accumulator ring (PAR), low energy transport (LET), booster synchrotron (SYNCH), high energy transport (HET), the storage ring (SR). Each subsystem has multiple magnet power supply combinations, some requiring multiple of operation. These magnet and power supply combinations computer controlled and monitored. The power supply control unit (PSCU) is the first layer of hardware and software above the power supply itself and is described in this paper. The description includes the basic philosophy for each of operation and how it influences the topology and of implementing control. The design of the analog reference blocks (ARBs) influenced the design of other custom functions well as the feedback controls for vibration and other dynamic corrections. The command set supported by the PSCU is discussed.

  5. Spacecraft high-voltage power supply construction

    NASA Technical Reports Server (NTRS)

    Sutton, J. F.; Stern, J. E.

    1975-01-01

    The design techniques, circuit components, fabrication techniques, and past experience used in successful high-voltage power supplies for spacecraft flight systems are described. A discussion of the basic physics of electrical discharges in gases is included and a design rationale for the prevention of electrical discharges is provided. Also included are typical examples of proven spacecraft high-voltage power supplies with typical specifications for design, fabrication, and testing.

  6. Very low-power power supplies

    NASA Technical Reports Server (NTRS)

    Roy, N. L.; Hoffmaster, D. K.

    1977-01-01

    Unit may be used in systems requiring milliwatt power for bias voltage functions and can be used as control mechanism for large electric power systems. Logic and energy storage techniques yield processing efficiencies of 1000 to 1 over conventional designs.

  7. Optimization of Resonant Power Supply Circuit

    SciTech Connect

    Karady, G.G.; Thiessen, H.A.

    1989-01-01

    A Resonant Power Supply has been proposed to power Rapid Cycling Accelerator magnets. The Resonant Power Supply circuits were studied extensively, but were not optimized. Most designs assume equal choke and magnet inductance, however, the variation of inductance affects both performance and cost of the system. This paper optimizes the Resonant Power Supply Circuit by selecting the most feasible choke inductance. For this optimization, a computer model and an approximate design method were developed. The effect of choke inductance on the components rating and cost was determined. It was found that the increase of choke inductance reduces the maximum and increases the minimum choke current, which leads to a significant increase of system losses. The maximum voltage is independent of the choke inductance. The described change of choke current reduces the current of the Bypass Thyristor Switch and the Capacitor Bank Switch, which results in cost reduction. The increase of choke inductance reduces the size of capacitor banks. The loss increase requires larger Make-up Power Supply and ac supply systems. It also increases the operation costs. The system cost function has a minimum, when the choke inductance is about 1.5--2 times larger than the magnet one. The application of the result will lead to a more economical and efficient Resonant Power Supply. 2 refs., 8 figs., 1 tab.

  8. New intelligent magnet power supplies for LAMPF

    SciTech Connect

    Cohen, S.; Sturrock, J.

    1991-01-01

    New magnet power supplies are scheduled to be installed in the proton linac at the Clinton P. Anderson Meson Physics Facility (LAMPF). The control and interface design of these power supplies represents a departure from all others onsite. A high-level ASCII control protocol has been designed. The supplies have sophisticated microprocessor control onboard and communicate with the accelerator control system via RS-422 (serial communications). The low-level software used by the accelerator control system is currently being rewritten to accommodate these new devices. They will communicate with the control system through a terminal server port connected to the site-wide ethernet backbone. This means that each supply will, for all intents and purposes, be a network object. Details of the design strategies for the analog and digital control for these supplies as well as the control protocol interface will be presented. 5 refs., 5 figs., 1 tab.

  9. E-beam high voltage switching power supply

    DOEpatents

    Shimer, Daniel W.; Lange, Arnold C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  10. E-beam high voltage switching power supply

    DOEpatents

    Shimer, D.W.; Lange, A.C.

    1997-03-11

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

  11. High power fast ramping power supplies

    SciTech Connect

    Marneris,I.; Bajon, E.; Bonati, R.; Sandberg, J.; Roser, T.; Tsoupas, N.

    2009-05-04

    Hundred megawatt level fast ramping power converters to drive proton and heavy ion machines are under research and development at accelerator facilities in the world. This is a leading edge technology. There are several topologies to achieve this power level. Their advantages and related issues will be discussed.

  12. A Unique Power Supply for the PEPII Klystron at SLAC

    NASA Astrophysics Data System (ADS)

    Cassel, R. L.; Nguyen, M. N.

    1997-05-01

    Each of the eight 1.2 MW RF klystrons for the PEP-II storage rings require a 2.5 MVA DC power supply of 83 kv at 23 amps. The design for the supply was base on three factors low cost, small size to fit existing substation pads, and good protection against damage to the klystron including klystron gun arcs. The supply uses a 12 pulse 12.5 KV primary thyristor ``star point controller'' with primary filter inductor to provide rapid voltage control, good voltage regulation, and fast turn off during klystron tube faults. The supply also uses a unique secondary rectifier, filter capacitor configuration to minimize the energy available under a klystron fault. The voltage control is from 0-90 KV with a regulation of < 0.1 % and voltage ripple of < 1 % P-P, (< 0.2 % RMS.) above 60 KV. The supply utilizes a thyristor crowbar, which under a klystron tube arc limits the energy in the klystron arc to < 5 joules. If the thyristor crowbar is disabled the energy supplied is < 40 joules into the arc. The size of the supply was reduced small enough to fit the existing PEP transformer yard pads. The cost of the power supply was < $ 140 per KVA.

  13. Digitally Controlled High Availability Power Supply

    SciTech Connect

    MacNair, David; /SLAC

    2009-05-07

    This paper will report on the test results of a prototype 1320 watt power module for a high availability power supply. The module will allow parallel operation for N+1 redundancy with hot swap capability. The two quadrant output of each module allows pairs of modules to provide a 4 quadrant (bipolar) operation. Each module employs a novel 4 FET buck regulator arranged in a bridge configuration. Each side of the bridge alternately conducts through a small saturable ferrite that limits the reverse current in the FET body diode during turn off. This allows hard switching of the FETs with low switching losses. The module is designed with over-rated components to provide high reliability and better then 97% efficiency at full load. The modules use a Microchip DSP for control, monitoring, and fault detection. The switching FETS are driven by PWM modules in the DSP at 60 KHz. A Dual CAN bus interface provides for low cost redundant control paths. The DSP will also provide current sharing between modules, synchronized switching, and soft start up for hot swapping. The input and output of each module have low resistance FETs to allow hot swapping and isolation of faulted units.

  14. 47 CFR 80.1015 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Radiotelephone Installations Required by the Bridge-to-Bridge Act § 80.1015 Power supply... to simultaneously energize the bridge-to-bridge transmitter at its required antenna power, and...

  15. A Quick Visual Power-Supply Monitor

    NASA Technical Reports Server (NTRS)

    Taylor, L. W.

    1986-01-01

    Power-supply voltages quickly monitored by circuit equipped with light-emitting-diode (LED) display. Operator looking at display quickly spots whether power output voltage is above, below, or within acceptable limits. Tricolor LED displays high, low, and intermediate output voltages.

  16. Advanced modular power supplies for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Krauthamer, S.; Gangal, M. D.; Detwiler, R. C.

    1990-01-01

    Viewgraphs and discussion on advanced modular power supplies for Space Station Freedom are presented. Topics covered include concept and characteristics; user power supply applications; and bulk converter application.

  17. Advanced buck converter power supply ABCPS for APT

    SciTech Connect

    Street, R.; Overett, T.; Bowles, E.

    1998-12-31

    The United States Department of Energy (DOE) is planning to fabricate an Accelerator for the Production of Tritium (APT) at their Savannah River Site, to provide Tritium for national defense. The 1700 million electron volt (MeV) proton beam accelerator will be powered by radio frequency (RF) klystrons. A direct current (DC) power supply is required for each of the approximately two hundred and fifty 1-megawatt (MW) continuous wave klystrons in the RF power system. The requirements are that the power supply meet output performance specifications, provide fault protection for the klystron, have high efficiency, high reliability, good maintainability, and be readily manufacturable. As the power supplies are one of the largest cost elements in the accelerator, a technology review was made to determine the most economical approach to satisfy the requirements. A switch-mode power supply employing a buck-regulator was identified as being potentially the lowest cost approach. As the switch represents a certain development risk, a small-scale prototype has been constructed for evaluation, and has resulted in the decision to fabricate a full-scale prototype power supply. A description of the hardware will be presented.

  18. Power supplies for hearing aids.

    PubMed

    Knutsen, J E

    1982-08-01

    The design of a hearing-aid system involves three disciplines of applied science--electrochemistry, electrical engineering and audio engineering. This paper is concerned with the interface between the first two. Batteries are essentially non-linear components. Optimum performance is only achievable when the electrical requirements of the hearing aid are closely matched with the voltage, rate capability and impedance of the battery. After years of optimalization, the modern '675' button cell has earned universal acceptability and is now used in most 'behind-the-ear' hearing aids. When more power is required, the larger and less specialized LR6 'penlight' cell is typically specified. Higher voltage might lead to better circuit efficiency, and there is some pressure to introduce a 3 V lithium-based product. Lithium should give superior energy density, but there are problems which remain to be solved. In the end, it is quite possible that the market might settle for an ecologically acceptable long-life lower voltage metal-air cell. If so, the recent zinc-air system may well have a future and could conceivably succeed both the mercury '675' and the alkaline 'penlight' cells. PMID:7171873

  19. Lunar surface fission power supplies: Radiation issues

    SciTech Connect

    Houts, M.G.; Lee, S.K.

    1994-07-01

    A lunar space fission power supply shield that uses a combination of lunar regolith and materials brought from earth may be optimal for early lunar outposts and bases. This type of shield can be designed such that the fission power supply does not have to be moved from its landing configuration, minimizing handling and required equipment on the lunar surface. Mechanisms for removing heat from the lunar regolith are built into the shield, and can be tested on earth. Regolith activation is greatly reduced compared with a shield that uses only regolith, and it is possible to keep the thermal conditions of the fission power supply close to these seen in free space. For a well designed shield, the additional mass required to be brought fro earth should be less than 1000 kg. Detailed radiation transport calculations confirm the feasibility of such a shield.

  20. Smart Power Supply for Battery-Powered Systems

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Greer, Lawrence; Prokop, Norman F.; Flatico, Joseph M.

    2010-01-01

    A power supply for battery-powered systems has been designed with an embedded controller that is capable of monitoring and maintaining batteries, charging hardware, while maintaining output power. The power supply is primarily designed for rovers and other remote science and engineering vehicles, but it can be used in any battery alone, or battery and charging source applications. The supply can function autonomously, or can be connected to a host processor through a serial communications link. It can be programmed a priori or on the fly to return current and voltage readings to a host. It has two output power busses: a constant 24-V direct current nominal bus, and a programmable bus for output from approximately 24 up to approximately 50 V. The programmable bus voltage level, and its output power limit, can be changed on the fly as well. The power supply also offers options to reduce the programmable bus to 24 V when the set power limit is reached, limiting output power in the case of a system fault detected in the system. The smart power supply is based on an embedded 8051-type single-chip microcontroller. This choice was made in that a credible progression to flight (radiation hard, high reliability) can be assumed as many 8051 processors or gate arrays capable of accepting 8051-type core presently exist and will continue to do so for some time. To solve the problem of centralized control, this innovation moves an embedded microcontroller to the power supply and assigns it the task of overseeing the operation and charging of the power supply assets. This embedded processor is connected to the application central processor via a serial data link such that the central processor can request updates of various parameters within the supply, such as battery current, bus voltage, remaining power in battery estimations, etc. This supply has a direct connection to the battery bus for common (quiescent) power application. Because components from multiple vendors may have

  1. Simulation of capacitor charging power supplies

    NASA Technical Reports Server (NTRS)

    Newton, S. R.; Nelms, R. M.

    1990-01-01

    By neglecting losses and other nonidealities, the authors were able to derive a simple single-loop equivalent circuit for each mode of operation of the series resonant converter. From these equivalent circuits, a good approximation of the current and voltages within the converter was obtained, despite the simplified approach taken. It is pointed out that designers of capacitor charging power supplies can utilize this approach in deciding what type of control strategy is needed to obtain a desired characteristic. Once the basic topology of the power supply has been determined, a detailed simulation could be implemented using one of the general-purpose software packages available.

  2. Overview of the ATR Power Supplies

    NASA Astrophysics Data System (ADS)

    Bruno, D.; Soukas, A.; Toldo, F.; Lambiase, B.

    1997-05-01

    The AGS to RHIC transfer Line (ATR) transports a variety of beams from the Alternating Gradient Synchrotron (AGS) which gets its input from the Booster Synchrotron. In turn, the Booster receives input beams from either a Tandem Van de Graaff (heavy ions) or a Linac(protons). The AGS extracts beam bunches, up to a rate of 30 Hertz, to the ATR which will eventually feed the Relativistic Heavy Ion Collider (RHIC) starting with the sextant test in January of 1996. The ATR is made up of the upgraded U line and the new W, X and Y lines. A test in 1995 transported beam to the end of the W line. During normal operation, a pulsed switching magnet at the end of the W line will bend the beam into the X line or the Y line so that the two rings in RHIC are filled with counter rotating beams. The ATR line is comprised of 80 power supplies (PS's), 17 of which are upgraded AGS PS's. The remaining 63 PS's were newly purchased. These PS's range from bipolar 600 watt linear type trim magnet PS's to 1 Megawatt, thyristor, dipole PS's. Results of the commissioning runs will be presented, as well as descriptions of regulation, filtering, and analog and digital controls.

  3. Overview of the ATR power supplies

    SciTech Connect

    Bruno, D.; Soukas, A.; Toldo, F.; Lambiase, R.F.

    1997-07-01

    The AGS to RHIC transfer line (ATR) transports a variety of beams from the Alternating Gradient Synchrotron (AGS) which gets its input from the Booster Synchrotron. In turn, the Booster receives input beams from either a Tandem Van de Graaff (heavy ions) or a Linac (protons). The AGS extracts beam bunches, up to a rate of 30 Hertz, to the ATR which feeds the Relativistic Heavy Ion Collider (RHIC) starting with the sextant test in January of 1997. The ATR is made up of the upgraded U line and the new W, X, and Y lines. A test in 1995 transported beam to the end of the W line. During normal operation, a pulsed switching magnet at the end of the W line will bend the beam into the X line or the Y line so that the two storage rings in RHIC are filled with counter rotating beams. The ATR line is comprised of 80 power supplies (PS`s), 17 of which are upgraded AGS PS`s. The remaining 63 PS`s were newly purchased. These PS`s range from bipolar 600 watt linear type trim magnet PS`s to 1 Megawatt, thyristor, dipole PS`s. Results of the commissioning runs will be presented, as well as descriptions of regulation, filtering, and analog and digital controls.

  4. SPEAR3 DC MAGNET POWER SUPPLIES - AN OVERVIEW

    SciTech Connect

    de Lira, A

    2004-03-25

    The Stanford Synchrotron Radiation Laboratory (SSRL) has successfully commissioned SPEAR 3, its newly upgraded 3-GeV synchrotron light source. First stored beam occurred December 15, 2003. This paper presents an overview and descriptions of the DC magnet power supplies. These consist of tightly-regulated ({le} 10 ppm) current sources ranging in output from 30 A to 800 A and output power ranging from a few watts to almost 1.0 MW. A total of 226 magnet power supplies are in successful operation. The SPEAR 3 upgrade performance and reliability requirements mandated new power supplies for both the SPEAR 3 storage ring, and for the booster-to-SPEAR 3 (BTS) transport line. A large variety of precise, highly stable current power supplies were needed to fill the diverse magnet needs. Also described are outside procurement aspects, in-house construction, installation, testing, performance and operation of the power supplies. During field testing, special emphasis was made to ensure a critically damped response on the current loop. Frequency spectra measurements were made for reference and future diagnostics.

  5. A high-power switch-mode dc power supply for dynamic loads

    SciTech Connect

    Shimer, D.W.; Lange, A.C.; Bombay, J.N.

    1994-06-23

    High-voltage dc power supplies are often required to operate with highly dynamic loads, such as arcs. A switch-mode dc power supply can offer significant advantages over conventional thyristor-based dc power supplies under such conditions. It can quickly turn off the supply to extinguish the arc, and it can quickly recover after the arc. It has a relatively small output filter capacitance, which results in small stored energy available to the arc. A 400-kW, 50-kV switch-mode dc power supply for an electron-beam gun that exploits these advantages was designed and tested. It uses four 100-kW, current-source-type dc-dc converters with inputs in parallel and outputs in series. The dc-dc converters operate at 20 kHz in the voltage regulator part and 10 kHz in the inverter, transformer, and output rectifier part of the circuit. Insulated gate bipolar transistors (IGBTs) are used as the power switches. Special techniques are used to protect the power supply and load against arcs and hard shorts. The power supply has an efficiency of 93%, an output voltage ripple of 1%, and fast dynamic response. In addition, it is nearly one-third the size of conventional power supplies.

  6. 47 CFR 80.917 - Reserve power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Reserve power supply. 80.917 Section 80.917... a reserve power supply located on the same deck as the main wheel house or at least one deck above the vessel's main deck, unless the main power supply is so situated. (b) The reserve power supply...

  7. 47 CFR 80.915 - Main power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Main power supply. 80.915 Section 80.915... supply. (a) There must be readily available for use under normal load conditions a main power supply... required receiver. Under this load condition the potential of the main power supply at the power...

  8. PEP-III magnet power conversion systems: Power supplies for large magnet strings

    SciTech Connect

    Jackson, T.; Saab, A.; Shimer, D.

    1995-05-01

    This paper presents the cooperative design efforts of LBL, SLAC, and LLNL on the magnet power conversion systems for PEP-II. The systems include 900 channels of correction magnet bipolar supplies and 400 unipolar supplies in the range of 5 to 500 kW. We show the decision process and technical considerations influencing the choice of power supply technologies employed. We also show the development of specifications that take maximum advantage of both the resources available and existing facilities while at the same time satisfying tight constraints for cost control, scheduling and coordination of different working groups. Switch-mode power conversion techniques will be used extensively in these systems, from the corrector supplies to the largest units if the dynamic performance specifications demand it. General system descriptions for each of the power supply ranges and for a new common control system interface and regulator are included.

  9. Arcjet power supply and start circuit

    NASA Technical Reports Server (NTRS)

    Gruber, Robert P. (Inventor)

    1988-01-01

    A dc power supply for spacecraft arcjet thrusters has an integral automatic starting circuit and an output averaging inductor. The output averaging inductor, in series with the load, provides instantaneous current control, and ignition pulse and an isolated signal proportional to the arc voltage. A pulse width modulated converter, close loop configured, is also incorporated to give fast response output current control.

  10. Power supply with optical-isolator control

    NASA Technical Reports Server (NTRS)

    Baker, R. H.; Wheeler, J. T.

    1977-01-01

    Power supply consists of several stages, interconnected and programmed for required output. In capacitor charging mode, transistor switches are closed. Last stage is in series with rectifier that prevents current from flowing backward into circuit. In capacitor discharge mode, transistor switches are closed, and voltage delivered to load is sum of voltages across capacitors.

  11. A new digital pulse power supply in heavy ion research facility in Lanzhou

    NASA Astrophysics Data System (ADS)

    Wang, Rongkun; Chen, Youxin; Huang, Yuzhen; Gao, Daqing; Zhou, Zhongzu; Yan, Huaihai; Zhao, Jiang; Shi, Chunfeng; Wu, Fengjun; Yan, Hongbin; Xia, Jiawen; Yuan, Youjin

    2013-11-01

    To meet the increasing requirements of the Heavy Ion Research Facility in Lanzhou-Cooler Storage Ring (HIRFL-CSR), a new digital pulse power supply, which employs multi-level converter, was designed. This power supply was applied with a multi H-bridge converters series-parallel connection topology. A new control model named digital power supply regulator system (DPSRS) was proposed, and a pulse power supply prototype based on DPSRS has been built and tested. The experimental results indicate that tracking error and ripple current meet the requirements of this design. The achievement of prototype provides a perfect model for HIRFL-CSR power supply system.

  12. 7 CFR 1710.303 - Power cost studies-power supply borrowers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Power cost studies-power supply borrowers. 1710.303 Section 1710.303 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE GENERAL AND PRE-LOAN POLICIES AND PROCEDURES COMMON TO ELECTRIC LOANS AND GUARANTEES Long-Range...

  13. NSTX power supply real time controller

    SciTech Connect

    Neumeyer, C.; Hatcher, R.; Marsala, R.; Ramakrishnan, S.

    2000-01-06

    The NSTX is a new national facility for the study of plasma confinement, heating, and current drive in a low aspect ratio, spherical torus (ST) configuration. The ST configuration is an alternate magnetic confinement concept which is characterized by high beta (ratio plasma pressure to magnetic field pressure) and low toroidal field compared to conventional tokamaks, and could provide a pathway to the realization of a practical fusion power source. The NSTX depends on a real time, high speed, synchronous, and deterministic control system acting on a system of thyristor rectifier power supplies to (1) establish the initial magnetic field configuration; (2) initiate plasma within the vacuum vessel; (3) inductively drive plasma current; and (4) control plasma position and shape. For the initial ``day 0'' 1st plasma operations (Feb. 1999), the system was limited to closed loop proportional-integral current control of the power supplies based on preprogrammed reference waveforms. For the ``day 1'' phase of operations beginning Sept. 1999 the loop has been closed on plasma current and position. This paper focuses on the Power Supply Real Time Controller (PSRTC).

  14. Direct current uninterruptible power supply method and system

    DOEpatents

    Sinha, Gautam

    2003-12-02

    A method and system are described for providing a direct current (DC) uninterruptible power supply with the method including, for example: continuously supplying fuel to a turbine; converting mechanical power from the turbine into alternating current (AC) electrical power; converting the AC electrical power to DC power within a predetermined voltage level range; supplying the DC power to a load; and maintaining a DC load voltage within the predetermined voltage level range by adjusting the amount of fuel supplied to the turbine.

  15. Power Supplies for High Energy Particle Accelerators

    NASA Astrophysics Data System (ADS)

    Dey, Pranab Kumar

    2016-06-01

    The on-going research and the development projects with Large Hadron Collider at CERN, Geneva, Switzerland has generated enormous enthusiasm and interest amongst all to know about the ultimate findings on `God's Particle'. This paper has made an attempt to unfold the power supply requirements and the methodology adopted to provide the stringent demand of such high energy particle accelerators during the initial stages of the search for the ultimate particles. An attempt has also been made to highlight the present status on the requirement of power supplies in some high energy accelerators with a view that, precautionary measures can be drawn during design and development from earlier experience which will be of help for the proposed third generation synchrotron to be installed in India at a huge cost.

  16. Power Supplies for High Energy Particle Accelerators

    NASA Astrophysics Data System (ADS)

    Dey, Pranab Kumar

    2015-05-01

    The on-going research and the development projects with Large Hadron Collider at CERN, Geneva, Switzerland has generated enormous enthusiasm and interest amongst all to know about the ultimate findings on `God's Particle'. This paper has made an attempt to unfold the power supply requirements and the methodology adopted to provide the stringent demand of such high energy particle accelerators during the initial stages of the search for the ultimate particles. An attempt has also been made to highlight the present status on the requirement of power supplies in some high energy accelerators with a view that, precautionary measures can be drawn during design and development from earlier experience which will be of help for the proposed third generation synchrotron to be installed in India at a huge cost.

  17. Power Supply Systems for Rapid Cycling Synchrotron

    NASA Astrophysics Data System (ADS)

    Watanabe, Yasuhiro; Adachi, Toshikazu; Someya, Hirohiko; Koseki, Shoichiro; Ogawa, Shinichi

    JAEA and KEK are jointly constructing a high intensity proton accelerator project J-PARC. Its main accelerator is 3GeV rapid cycling synchrotron (RCS). Two types of resonant excitation systems, parallel and cascade, are introduced to excite DC biased 25Hz AC currents through its main magnets. The parallel excitation is adopted for dipole magnets power supply system, and the cascade excitations are adopted for seven family quadrupole magnets systems. In this paper, two systems are investigated and analyzed, and it is explained why different types are adopted to each system. Authors believe that such hybrid exciting systems are most suitable for high power RCS.

  18. 14 CFR 29.1331 - Instruments using a power supply.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Instruments using a power supply. 29.1331....1331 Instruments using a power supply. For category A rotorcraft— (a) Each required flight instrument using a power supply must have— (1) Two independent sources of power; (2) A means of selecting...

  19. 14 CFR 25.1331 - Instruments using a power supply.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... instrument must, in the event of the failure of one power source, be supplied by another power source. This... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Instruments using a power supply. 25.1331....1331 Instruments using a power supply. (a) For each instrument required by § 25.1303(b) that uses...

  20. Correction magnet power supplies for APS machine

    SciTech Connect

    Kang, Y.G.

    1991-04-01

    A number of correction magnets are required for the advanced photon source (APS) machine to correct the beam. There are five kinds of correction magnets for the storage ring, two for the injector synchrotron, and two for the positron accumulator ring (PAR). Table I shoes a summary of the correction magnet power supplies for the APS machine. For the storage ring, the displacement of the quadrupole magnets due to the low frequency vibration below 25 Hz has the most significant effect on the stability of the positron closed orbit. The primary external source of the low frequency vibration is the ground motion of approximately 20 {mu}m amplitude, with frequency components concentrated below 10 Hz. These low frequency vibrations can be corrected by using the correction magnets, whose field strengths are controlled individually through the feedback loop comprising the beam position monitoring system. The correction field require could be either positive or negative. Thus for all the correction magnets, bipolar power supplies (BPSs) are required to produce both polarities of correction fields. Three different types of BPS are used for all the correction magnets. Type I BPSs cover all the correction magnets for the storage ring, except for the trim dipoles. The maximum output current of the Type I BPS is 140 Adc. A Type II BPS powers a trim dipole, and its maximum output current is 60 Adc. The injector synchrotron and PAR correction magnets are powered form Type III BPSs, whose maximum output current is 25 Adc.

  1. Ultracapacitor-Based Uninterrupted Power Supply System

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.

    2011-01-01

    The ultracapacitor-based uninterrupted power supply (UPS) system enhances system reliability; reduces life-of-system, maintenance, and downtime costs; and greatly reduces environmental impact when compared to conventional UPS energy storage systems. This design provides power when required and absorbs power when required to smooth the system load and also has excellent low-temperature performance. The UPS used during hardware tests at Glenn is an efficient, compact, maintenance-free, rack-mount, pure sine-wave inverter unit. The UPS provides a continuous output power up to 1,700 W with a surge rating of 1,870 W for up to one minute at a nominal output voltage of 115 VAC. The ultracapacitor energy storage system tested in conjunction with the UPS is rated at 5.8 F. This is a bank of ten symmetric ultracapacitor modules. Each module is actively balanced using a linear voltage balancing technique in which the cell-to-cell leakage is dependent upon the imbalance of the individual cells. The ultracapacitors are charged by a DC power supply, which can provide up to 300 VDC at 4 A. A constant-voltage, constant-current power supply was selected for this application. The long life of ultracapacitors greatly enhances system reliability, which is significant in critical applications such as medical power systems and space power systems. The energy storage system can usually last longer than the application, given its 20-year life span. This means that the ultracapacitors will probably never need to be replaced and disposed of, whereas batteries require frequent replacement and disposal. The charge-discharge efficiency of rechargeable batteries is approximately 50 percent, and after some hundreds of charges and discharges, they must be replaced. The charge-discharge efficiency of ultracapacitors exceeds 90 percent, and can accept more than a million charges and discharges. Thus, there is a significant energy savings through the efficiency improvement, and there is far less

  2. Westinghouse programs in pulsed homopolar power supplies

    NASA Technical Reports Server (NTRS)

    Litz, D. C.; Mullan, E.

    1984-01-01

    This document details Westinghouse's ongoing study of homopolar machines since 1929 with the major effort occurring in the early 1970's to the present. The effort has enabled Westinghouse to develop expertise in the technology required for the design, fabrication and testing of such machines. This includes electrical design, electromagnetic analysis, current collection, mechanical design, advanced cooling, stress analysis, transient rotor performance, bearing analysis and seal technology. Westinghouse is using this capability to explore the use of homopolar machines as pulsed power supplies for future systems in both military and commercial applications.

  3. Programmable Multiple-Ramped-Voltage Power Supply

    NASA Technical Reports Server (NTRS)

    Ajello, Joseph M.; Howell, S. K.

    1993-01-01

    Ramp waveforms range up to 2,000 V. Laboratory high-voltage power-supply system puts out variety of stable voltages programmed to remain fixed with respect to ground or float with respect to ramp waveform. Measures voltages it produces with high resolution; automatically calibrates, zeroes, and configures itself; and produces variety of input/output signals for use with other instruments. Developed for use with ultraviolet spectrometer. Also applicable to control of electron guns in general and to operation of such diverse equipment used in measuring scattering cross sections of subatomic particles and in industrial electron-beam welders.

  4. Pulse Power Supply for Plasma Dynamic Accelerator

    NASA Astrophysics Data System (ADS)

    Yang, Xuanzong; Liu, Jian; Feng, Chunhua; Wang, Long

    2008-06-01

    A new concept of a coaxial plasma dynamic accelerator with a self-energized magnetic compressor coil to simulate the effects of space debris impact is demonstrated. A brief description is presented about the pulse power supply system including the charging circuit, start switch and current transfer system along with some of the key techniques for this kind of accelerator. Using this accelerator configuration, ceramic beads of 100 fim in diameter were accelerated to a speed as high as 18 km/sec. The facility can be used in a laboratory setting to study impact phenomena on solar array materials, potential structural materials for use in space.

  5. 47 CFR 80.963 - Main power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Main power supply. 80.963 Section 80.963... MARITIME SERVICES Radiotelephone Installation Required for Vessels on the Great Lakes § 80.963 Main power supply. (a) A main power supply must be available at all times while the vessel is subject to...

  6. 49 CFR 236.551 - Power supply voltage; requirement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply voltage; requirement. 236.551 Section... Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.551 Power supply voltage; requirement. The voltage of power supply shall be maintained within 10 percent of...

  7. 47 CFR 80.875 - VHF radiotelephone power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false VHF radiotelephone power supply. 80.875 Section... to Subpart W § 80.875 VHF radiotelephone power supply. (a) There must be readily available for use under normal load conditions a power supply sufficient to simultaneously energize the VHF transmitter...

  8. 47 CFR 80.965 - Reserve power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Reserve power supply. 80.965 Section 80.965... power supply. (a) Each passenger vessel of more than 100 gross tons and each cargo vessel of more than 300 gross tons must be provided with a reserve power supply independent of the vessel's...

  9. 47 CFR 80.963 - Main power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Main power supply. 80.963 Section 80.963... MARITIME SERVICES Radiotelephone Installation Required for Vessels on the Great Lakes § 80.963 Main power supply. (a) A main power supply must be available at all times while the vessel is subject to...

  10. Thematic mapper flight model preshipment review data package. Volume 4: Appendix. Part C: Power supply data

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The acceptance test data package for the thematic mapper flight model power supply was reviewed and the data compared to the relevant specification. The power supply was found to be within specification. Final test data for outut voltage regulation and ripple, efficiency, over and undervoltage protection, telemetry, impedances, turn-on requirements, and input current limits are presented.

  11. Hold-up power supply for flash memory

    NASA Technical Reports Server (NTRS)

    Ott, William E. (Inventor)

    2004-01-01

    A hold-up power supply for flash memory systems is provided. The hold-up power supply provides the flash memory with the power needed to temporarily operate when a power loss exists. This allows the flash memory system to complete any erasures and writes, and thus allows it to shut down gracefully. The hold-up power supply detects when a power loss on a power supply bus is occurring and supplies the power needed for the flash memory system to temporally operate. The hold-up power supply stores power in at least one capacitor. During normal operation, power from a high voltage supply bus is used to charge the storage capacitors. When a power supply loss is detected, the power supply bus is disconnected from the flash memory system. A hold-up controller controls the power flow from the storage capacitors to the flash memory system. The hold-up controller uses feedback to assure that the proper voltage is provided from the storage capacitors to the flash memory system. This power supplied by the storage capacitors allows the flash memory system to complete any erasures and writes, and thus allows the flash memory system to shut down gracefully.

  12. Essays in market power mitigation and supply function equilibrium

    NASA Astrophysics Data System (ADS)

    Subramainam, Thiagarajah Natchie

    Market power mitigation has been an integral part of wholesale electricity markets since deregulation. In wholesale electricity markets, different regions in the US take different approaches to regulating market power. While the exercise of market power has received considerable attention in the literature, the issue of market power mitigation has attracted scant attention. In the first chapter, I examine the market power mitigation rules used in New York ISO (Independent System Operator) and California ISO (CAISO) with respect to day-ahead and real-time energy markets. I test whether markups associated with New York in-city generators would be lower with an alternative approach to mitigation, the CAISO approach. Results indicate the difference in markups between these two mitigation rules is driven by the shape of residual demand curves for suppliers. Analysis of residual demand curves faced by New York in-city suppliers show similar markups under both mitigation rules when no one supplier is necessary to meet the demand (i.e., when no supplier is pivotal). However, when some supplier is crucial for the market to clear, the mitigation rule adopted by the NYISO consistently leads to higher markups than would the CAISO rule. This result suggest that market power episodes in New York is confined to periods where some supplier is pivotal. As a result, I find that applying the CAISOs' mitigation rules to the New York market could lower wholesale electricity prices by 18%. The second chapter of my dissertation focuses on supply function equilibrium. In power markets, suppliers submit offer curves in auctions, indicating their willingness to supply at different price levels. Although firms are allowed to submit different offer curves for different time periods, surprisingly many firms stick to a single offer curve for the entire day. This essentially means that firms are submitting a single offer curve for multiple demand realizations. A suitable framework to analyze

  13. 275 C Downhole Switched-Mode Power Supply

    SciTech Connect

    Chris Hutchens; Vijay Madhuravasal

    2008-08-31

    A vee-square (V2) control based controller IC is developed for a switch mode power supply capable of operating at extreme temperature/harsh environment conditions. A buck type regulator with silicon carbide power junction field effect transistors (JFET) as power devices is used to analyze the performance of controller. Special emphases are made on the analog sub-blocks--voltage reference, operational transconductance amplifier and comparator as individual building blocks. Transformer coupled gate drives and high temperature operable magnetic cores and capacitors are identified and tested for use in the design. Conventional ceramic chip packaging of ICs combined with lead carrier type mounting of passive filter components is introduced for hybrid packaging of the complete product. The developed SMPS is anticipated to support the operation of down-hole microcontrollers and other electronics devices that require low/medium power filtered dc inputs over an operating temperature of 275 C.

  14. Application of power-factor correction in the Tandem Mirror Experiment Upgrade magnet power supply

    SciTech Connect

    Corvin, W.C.

    1981-08-14

    The magnet power supply for the Tandem Mirror Experiment Upgrade (TMX Upgrade) contains 24 groups of dc rectifiers that feed the water-cooled magnets. Each group consists of five or less rectifiers, connected in series. All 24 are current-regulating, using phase-controlled bilateral thyristors in the rectifier transformer primaries. The electric utility system must furnish reactive power to these phase-controlled thyristors as well as to the cmmutating diodes in the rectifier bridges.

  15. 14 CFR 29.1331 - Instruments using a power supply.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....1331 Instruments using a power supply. For category A rotorcraft— (a) Each required flight instrument... power source; and (3) A visual means integral with each instrument to indicate when the power adequate to sustain proper instrument performance is not being supplied. The power must be measured at or...

  16. 14 CFR 29.1331 - Instruments using a power supply.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ....1331 Instruments using a power supply. For category A rotorcraft— (a) Each required flight instrument... power source; and (3) A visual means integral with each instrument to indicate when the power adequate to sustain proper instrument performance is not being supplied. The power must be measured at or...

  17. Neutron generator power supply modeling in EMMA

    SciTech Connect

    Robinson, A.C.; Farnsworth, A.V.; Montgomery, S.T.; Peery, J.S; Merewether, K.O.

    1996-12-01

    Sandia National Laboratories has prime responsibility for neutron generator design and manufacturing, and is committed to developing predictive tools for modeling neutron generator performance. An important aspect of understanding component performance is explosively driven ferroelectric power supply modeling. EMMA (ElectroMechanical Modeling in ALEGRA) is a three dimensional compile time version of Sandia`s ALEGRA code. The code is built on top of the general ALEGRA framework for parallel shock-physics computations but also includes additional capability for modeling the electric potential field in dielectrics. The overall package includes shock propagation due to explosive detonation, depoling of ferroelectric ceramics, electric field calculation and coupling with a general lumped element circuit equation system. The AZTEC parallel iterative solver is used to solve for the electric potential. The DASPK differential algebraic equation package is used to solve the circuit equation system. Sample calculations are described.

  18. Steering magnet power supply control system for the TRISTAN AR

    SciTech Connect

    Kubo, T.; Endo, K.; Fukuma, H.; Kabe, A.; Ozaki, T.

    1985-10-01

    The closed orbit distortion of TRISTAN Accumulation Ring (AR) is corrected by the steering magnets (correction dipole magnets). These magnets are excited by the bipolar power supplies with the rated power of about 1 KVA. The power supplies are controlled remotely through the serial camac dataway. The camac modules which include the microprocessor are developed for this system and these modules send out the reference current patterns to the individual power supply.

  19. Analysis of a parallel-arrayed power regulating system

    NASA Technical Reports Server (NTRS)

    Colburn, B. K.; Horton, H. M.; Honnell, M. A.

    1979-01-01

    A power regulation system incorporating n-parallel power supplies employing PWM switching regulators is studied. Analysis of individual unit operation and coupled-system parameter sensitivity is considered from an operations viewpoint. A detailed example is included to illustrate parallel system operation for 18 such units powered by solar-cell banks.

  20. Sea water magnesium fuel cell power supply

    NASA Astrophysics Data System (ADS)

    Hahn, Robert; Mainert, Jan; Glaw, Fabian; Lang, K.-D.

    2015-08-01

    An environmentally friendly magnesium fuel cell system using seawater electrolyte and atmospheric oxygen was tested under practical considerations for use as maritime power supply. The hydrogen rate and therefore the power density of the system were increased by a factor of two by using hydrogen evolution cathodes with a gas separation membrane instead of submerged cathodes without gas separation. Commercial magnesium AZ31 rolled sheet anodes can be dissolved in seawater for hydrogen production, down to a thickness below 100 μm thickness, resulting in hydrogen generation efficiency of the anode of over 80%. A practical specific energy/energy density of the alloy of more than 1200 Wh/kg/3000 Wh/l was achieved when coupled to a fuel cell with atmospheric air breathing cathode. The performance of several AZ31 alloy anodes was tested as well as the influence of temperature, electrolyte concentration and anode - cathode separation. The excess hydrogen produced by the magnesium hydrogen evolving cell, due to the negative difference effect, is proportional to the cell current in case of the AZ31 alloys, which simplifies system control considerably. Stable long-term operation of the system was demonstrated at low pressures which can be maintained in an open-seawater-submerged hydrogen generator.

  1. 47 CFR 80.917 - Reserve power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Reserve power supply. 80.917 Section 80.917... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.917 Reserve power... reserve power supply located on the same deck as the main wheel house or at least one deck above...

  2. 47 CFR 80.915 - Main power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Main power supply. 80.915 Section 80.915... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.915 Main power supply. (a) There must be readily available for use under normal load conditions a main power...

  3. Pulse-width-modulated high-current power supply

    NASA Technical Reports Server (NTRS)

    Messano, E. A.; Moore, H. E.

    1977-01-01

    Power supply achieves efficiency rating of approximately 80 percent at rated maximum output current. Protection circuitry prevents logic/memory loads from losing stored data if supply protection circuit initiates power shut down; prevents damage caused by overtemperature condition; protects logic/memory load from undervoltage to overvoltage conditions. Warning signal indicates power shutdown.

  4. 46 CFR 113.43-5 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm... alarm circuits; (b) Is fed from the final emergency power source through the emergency...

  5. 46 CFR 113.43-5 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm... alarm circuits; (b) Is fed from the final emergency power source through the emergency...

  6. 46 CFR 113.10-9 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.10-9 Section 113.10-9 Shipping COAST... SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-9 Power supply. (a) General. There must be at least two sources of power for the electrical equipment of each fire detecting...

  7. 46 CFR 113.10-9 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Power supply. 113.10-9 Section 113.10-9 Shipping COAST... SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-9 Power supply. (a) General. There must be at least two sources of power for the electrical equipment of each fire detecting...

  8. 46 CFR 113.10-9 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Power supply. 113.10-9 Section 113.10-9 Shipping COAST... SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-9 Power supply. (a) General. There must be at least two sources of power for the electrical equipment of each fire detecting...

  9. 46 CFR 113.43-5 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm... alarm circuits; (b) Is fed from the final emergency power source through the emergency...

  10. 46 CFR 113.43-5 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm... alarm circuits; (b) Is fed from the final emergency power source through the emergency...

  11. 46 CFR 113.10-9 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Power supply. 113.10-9 Section 113.10-9 Shipping COAST... SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-9 Power supply. (a) General. There must be at least two sources of power for the electrical equipment of each fire detecting...

  12. 46 CFR 113.10-9 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Power supply. 113.10-9 Section 113.10-9 Shipping COAST... SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-9 Power supply. (a) General. There must be at least two sources of power for the electrical equipment of each fire detecting...

  13. 46 CFR 113.43-5 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm... alarm circuits; (b) Is fed from the final emergency power source through the emergency...

  14. Power supply with air core transformer and seperated power supplies for high dynamic range

    NASA Technical Reports Server (NTRS)

    Chutjian, Ara (Inventor); Aalami, Dean (Inventor); Darrach, Murray (Inventor); Orient, Otto (Inventor)

    2001-01-01

    A power supply for a quadrupole mass spectrometer which operates using an RF signal. The RF signal is controllable via a feedback loop. The feedback loop is from the output, through a comparator, and compared to a digital signal. An air core transformer is used to minimize the weight. The air core transformer is driven via two out of phase sawtooth signals which drive opposite ends of the transformer.

  15. Reduction of power supply EMI emission by switching frequency modulation

    SciTech Connect

    Lin, F.; Chen, D.Y. . Virginia Power Electronics Center)

    1994-01-01

    Electro-Magnetic Interference (EMI) emission is always of grave concern for power electronic circuit designers. Due to rapid switching of high current and high voltage, interference emission is a serious problem in switching power circuits. Many products fail to make it to the market because of their failure to comply with the government EMI regulations. Numerous companies have cited EMI problems as the culprit in the delay of their product introduction. EMI noise reduction is generally accomplished by three means: suppression of noise source, isolation of noise coupling path, and filter/shielding. In this paper, another means of EMI noise reduction is proposed. By modulating the PWM frequency of power supply, it is possible to modify noise emission spectrum so that it can pass government EMI regulations. In the paper, measurement of EMI noise is first reviewed. Noise sources of a power switching circuit are then described. The theoretical and the experimental results of the reduction of EMI noise emission by sinewave frequency modulation to distribute the power of the fundamental harmonics onto frequency sideband are discussed.

  16. Magnetically switched power supply system for lasers

    NASA Technical Reports Server (NTRS)

    Pacala, Thomas J. (Inventor)

    1987-01-01

    A laser power supply system is described in which separate pulses are utilized to avalanche ionize the gas within the laser and then produce a sustained discharge to cause the gas to emit light energy. A pulsed voltage source is used to charge a storage device such as a distributed capacitance. A transmission line or other suitable electrical conductor connects the storage device to the laser. A saturable inductor switch is coupled in the transmission line for containing the energy within the storage device until the voltage level across the storage device reaches a predetermined level, which level is less than that required to avalanche ionize the gas. An avalanche ionization pulse generating circuit is coupled to the laser for generating a high voltage pulse of sufficient amplitude to avalanche ionize the laser gas. Once the laser gas is avalanche ionized, the energy within the storage device is discharged through the saturable inductor switch into the laser to provide the sustained discharge. The avalanche ionization generating circuit may include a separate voltage source which is connected across the laser or may be in the form of a voltage multiplier circuit connected between the storage device and the laser.

  17. Statistical modelling of mitochondrial power supply.

    PubMed

    James, A T; Wiskich, J T; Conyers, R A

    1989-01-01

    By experiment and theory, formulae are derived to calculate the response of mitochondrial power supply, in flux and potential, to an ATP consuming enzyme load, incorporating effects of varying amounts of (i) enzyme, (ii) total circulating adenylate, and (iii) inhibition of the ATP/ADP translocase. The formulae, which apply between about 20% and 80% of maximum respiration, are the same as for the current and voltage of an electrical circuit in which a battery with potential, linear in the logarithm of the total adenylate, charges another battery whose opposing potential is also linear in the same logarithm, through three resistances. These resistances produce loss of potential due to dis-equilibrium of (i) intramitochondrial oxidative phosphorylation, (ii) the ATP/ADP translocase, and (iii) the ATP-consuming enzyme load. The model is represented geometrically by the following configuration: when potential is plotted against flux, the points lie on two pencils of lines each concurrent at zero respiration, the two pencils describing the respective characteristics of the mitochondrion and enzyme. Control coefficients and elasticities are calculated from the formulae. PMID:2708917

  18. Static DC to DC Power Conditioning-Active Ripple Filter, 1 MHZ DC to DC Conversion, and Nonlinear Analysis. Ph.D. Thesis; [voltage regulation and conversion circuitry for spacecraft power supplies

    NASA Technical Reports Server (NTRS)

    Sander, W. A., III

    1973-01-01

    Dc to dc static power conditioning systems on unmanned spacecraft have as their inputs highly fluctuating dc voltages which they condition to regulated dc voltages. These input voltages may be less than or greater than the desired regulated voltages. The design of two circuits which address specific problems in the design of these power conditioning systems and a nonlinear analysis of one of the circuits are discussed. The first circuit design is for a nondissipative active ripple filter which uses an operational amplifier to amplify and cancel the sensed ripple voltage. A dc to dc converter operating at a switching frequency of 1 MHz is the second circuit discussed. A nonlinear analysis of the type of dc to dc converter utilized in designing the 1 MHz converter is included.

  19. Development of compact high voltage switched mode power supply for microwave plasma sources supply for low pressure plasma

    NASA Astrophysics Data System (ADS)

    Kerdtongmee, P.; Srinoum, D.; Nisoa, M.

    2011-08-01

    Although microwave induced plasmas are well known as high efficiency plasma sources, their uses in laboratories are limited since the microwave power systems are complicated and expensive. The output power of commercially available low-cost microwave ovens is fixed and discontinuous resulting from the high voltage doubler topology of the magnetron tube power supply. In this paper, a high voltage switched mode power supply of forward topology has been developed for continuous microwave power radiation. The forward converter can generate a no-load high voltage output maximum of 7 kV. When driving the magnetron tube, the microwave output power could be varied from 0 to 35 W while the high voltage output level was constantly regulated at -3.4 kV. A microwave induced plasma system was setup to investigate the plasma produced. A low pressure argon plasma was produced with only 2 W over a wide range of pressures.

  20. 141. NITROGEN SUPPLY PANEL PRESSURE REGULATOR IN NORTHWEST CORNER OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    141. NITROGEN SUPPLY PANEL PRESSURE REGULATOR IN NORTHWEST CORNER OF CONTROL ROOM (214), LSB (BLDG. 751), FACING WEST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. Federal Powers of Regulation.

    ERIC Educational Resources Information Center

    Rhyne, William S.

    1979-01-01

    Reflects the special considerations in affecting, rather than merely evaluating, the outcome of constitutional litigation over federal regulation of state and local government labor relations. (Author/IRT)

  2. Transforming PC Power Supplies into Smart Car Battery Conditioners

    ERIC Educational Resources Information Center

    Rodriguez-Ascariz, J. M.; Boquete-Vazquez, L.

    2011-01-01

    This paper describes a laboratory project consisting of a PC power supply modification into an intelligent car-battery conditioner with both wireless and wired networking capabilities. Adding a microcontroller to an average PC power supply transforms it into a flexible, intelligent device that can be configured and that is suitable to keep car…

  3. 14 CFR 25.1331 - Instruments using a power supply.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Instruments using a power supply. 25.1331 Section 25.1331 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Instruments: Installation § 25.1331 Instruments using a power supply. (a)...

  4. 10 CFR 429.37 - Class A external power supplies.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... external power supplies; and (2) For each basic model of external power supply selected for testing, a... of the estimated energy consumption of a basic model for which consumers would favor lower values... and (ii) Any represented value of the estimated energy consumption of a basic model for...

  5. Control Electronics for Solar/Flywheel Power Supply

    NASA Technical Reports Server (NTRS)

    Nola, F. J.

    1986-01-01

    Control circuit automatically directs flow of electrical energy to and from motor with flywheel that constitutes storage element of solar-power system. When insolation is sufficient for charging, power is supplied by solar-cell array to load and motor. During periods of darkness, motor made to act as generator, drawing kinetic energy from flywheel and supplying it to load.

  6. 14 CFR 29.1331 - Instruments using a power supply.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Instruments using a power supply. 29.1331 Section 29.1331 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Instruments: Installation § 29.1331 Instruments using a power supply....

  7. 14 CFR 29.1331 - Instruments using a power supply.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Instruments using a power supply. 29.1331 Section 29.1331 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Instruments: Installation § 29.1331 Instruments using a power supply....

  8. 47 CFR 80.860 - Reserve power supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Reserve power supply. 80.860 Section 80.860... MARITIME SERVICES Technical Equipment Requirements for Cargo Vessels Not Subject to Subpart W § 80.860... least one deck above the vessel's main deck, a reserve power supply must be provided and must be...

  9. 47 CFR 80.860 - Reserve power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Reserve power supply. 80.860 Section 80.860... MARITIME SERVICES Technical Equipment Requirements for Cargo Vessels Not Subject to Subpart W § 80.860... least one deck above the vessel's main deck, a reserve power supply must be provided and must be...

  10. Regulating the cellular economy of supply and demand.

    PubMed

    Hofmeyr, J S; Cornish-Bowden, A

    2000-06-30

    Cellular metabolism is a molecular economy that is functionally organised into supply and demand blocks linked by metabolic products and cofactor cycles. Supply-demand analysis allows the behaviour, control and regulation of metabolism as a whole to be understood quantitatively in terms of the elasticities of supply and demand, which are experimentally measurable properties of the individual blocks. The kinetic and thermodynamic aspects of regulation are clearly distinguished. One important result is the demonstration that when flux is controlled by one block, the other block determines to which degree the concentration of the linking metabolite is homeostatically maintained. PMID:10878248

  11. POWER SUPPLY CONTROL FOR THE SPALLATION NEUTRON SOURCE.

    SciTech Connect

    LAMBIASE, R.F.; OERTER, B.; SMITH, J.

    2000-06-30

    Brookhaven National Laboratory is currently constructing an accumulator ring as part of a six laboratory collaboration to build the Spallation Neutron Source (SNS) that will be located in Oak Ridge, Tennessee. Control of the power supplies will be implemented using a simple integrated system that provides all functions (setpoint, readback, control and status) with a single board at the power converter. Communication between the power supply interface and the VME control card is through a pair of fibers that also provides electrical isolation. This paper describes the power supply control system and it's impact on the SNS.

  12. A real time status monitor for transistor bank driver power limit resistor in boost injection kicker power supply

    SciTech Connect

    Mi, J.; Tan, Y.; Zhang, W.

    2011-03-28

    For years suffering of Booster Injection Kicker transistor bank driver regulator troubleshooting, a new real time monitor system has been developed. A simple and floating circuit has been designed and tested. This circuit monitor system can monitor the driver regulator power limit resistor status in real time and warn machine operator if the power limit resistor changes values. This paper will mainly introduce the power supply and the new designed monitoring system. This real time resistor monitor circuit shows a useful method to monitor some critical parts in the booster pulse power supply. After two years accelerator operation, it shows that this monitor works well. Previously, we spent a lot of time in booster machine trouble shooting. We will reinstall all 4 PCB into Euro Card Standard Chassis when the power supply system will be updated.

  13. Electric Transport Traction Power Supply System With Distributed Energy Sources

    NASA Astrophysics Data System (ADS)

    Abramov, E. Y.; Schurov, N. I.; Rozhkova, M. V.

    2016-04-01

    The paper states the problem of traction substation (TSS) leveling of daily-load curve for urban electric transport. The circuit of traction power supply system (TPSS) with distributed autonomous energy source (AES) based on photovoltaic (PV) and energy storage (ES) units is submitted here. The distribution algorithm of power flow for the daily traction load curve leveling is also introduced in this paper. In addition, it illustrates the implemented experiment model of power supply system.

  14. Intelligent vehicle electrical power supply system with central coordinated protection

    NASA Astrophysics Data System (ADS)

    Yang, Diange; Kong, Weiwei; Li, Bing; Lian, Xiaomin

    2016-05-01

    The current research of vehicle electrical power supply system mainly focuses on electric vehicles (EV) and hybrid electric vehicles (HEV). The vehicle electrical power supply system used in traditional fuel vehicles is rather simple and imperfect; electrical/electronic devices (EEDs) applied in vehicles are usually directly connected with the vehicle's battery. With increasing numbers of EEDs being applied in traditional fuel vehicles, vehicle electrical power supply systems should be optimized and improved so that they can work more safely and more effectively. In this paper, a new vehicle electrical power supply system for traditional fuel vehicles, which accounts for all electrical/electronic devices and complex work conditions, is proposed based on a smart electrical/electronic device (SEED) system. Working as an independent intelligent electrical power supply network, the proposed system is isolated from the electrical control module and communication network, and access to the vehicle system is made through a bus interface. This results in a clean controller power supply with no electromagnetic interference. A new practical battery state of charge (SoC) estimation method is also proposed to achieve more accurate SoC estimation for lead-acid batteries in traditional fuel vehicles so that the intelligent power system can monitor the status of the battery for an over-current state in each power channel. Optimized protection methods are also used to ensure power supply safety. Experiments and tests on a traditional fuel vehicle are performed, and the results reveal that the battery SoC is calculated quickly and sufficiently accurately for battery over-discharge protection. Over-current protection is achieved, and the entire vehicle's power utilization is optimized. For traditional fuel vehicles, the proposed vehicle electrical power supply system is comprehensive and has a unified system architecture, enhancing system reliability and security.

  15. Solid-state power supply for gas lasers

    NASA Astrophysics Data System (ADS)

    Bertolini, A.; Beverini, N.; Carelli, G.; Francesconi, M.; Nannizzi, M.; Strumia, F.; Ioli, N.; Moretti, A.

    2004-08-01

    A novel pulsed power supply for gas lasers is presented. The device uses only solid state components and is based on a capacitor bank discharge. Fast switching of the discharge is triggered by an insulated gate bipolar transistor. The terminal section of the power supply is a transformer designed to match the reactive capacitance of a gas discharge. Strokes up to 30 kV and 30 mA are achieved across the secondary windings of this transformer. The power supply delivers high voltage pulses with a duration between 0.5 and 50 μs and a repetition rate up to some kHz. The power supply has been tested on a longitudinal discharge quasi-cw regime CO2 laser. Laser pulses were generated with a duration down to the microseconds region, a peak power exceeding some kilowatts, and a repetition rate ranging from 200 Hz to a few kHz.

  16. Tokamak Physics Experiment (TPX) power supply design and development

    SciTech Connect

    Neumeyer, C.; Bronner, G.; Lu, E.; Ramakrishnan, S.

    1995-04-01

    The Tokamak Physics Experiment (TPX) is an advanced tokamak project aimed at the production of quasi-steady state plasmas with advanced shape, heating, and particle control. TPX is to be built at the Princeton Plasma Physics Laboratory (PPPL) using many of the facilities from the Tokamak Fusion Test Reactor (TFTR). TPX will be the first tokamak to utilize superconducting (SC) magnets in both the toroidal field (TF) and poloidal field (PF) systems. This new feature requires a departure from the traditional tokamak power supply schemes. This paper describes the plan for the adaptation of the PPPL/FTR power system facilities to supply TPX. Five major areas are addressed, namely the AC power system, the TF, PF and Fast Plasma Position Control (FPPC) power supplies, and quench protection for the TF and PF systems. Special emphasis is placed on the development of new power supply and protection schemes.

  17. Self-adjusting anode power supply for a gyrotron

    SciTech Connect

    Brand, G.F.; Fekete, P.W.; Hong, K. ); Idehara, T.; Tatsukawa, T. )

    1991-02-01

    Sydney University's tunable cw gyrotrons use a simplified power supply arrangement to provide the voltages on the gun electrodes. The cathode supply is conventional, but the anode voltage is provided by a single high-value resistor connected between the anode and ground. A small fraction of the electrons in the beam are reflected and the anode automatically finds an optimum operating potential. This arrangement is shown to have lower starting currents. Two advantages follow. It becomes easier to operate low-power gyrotrons with modest power supplies and it becomes easier to achieve higher frequencies by exciting harmonics of the electron cyclotron frequency.

  18. Power supply control units for APS ring magnets

    SciTech Connect

    Despe, O.D.

    1990-04-15

    The APS storage ring (1104 meters) is divided into 40 sectors. Each sector has 38 magnet coils in five magnet bases. Every alternate sector has an additional quadrupole magnet for skew correction. AR the main dipole magnets, two in each sector are connected in series and fed from one power supply unit. A base is controlled by one power supply control unit (PSCU). Each PSCU is connected to the host computer via a local area network (LAN). This note discusses the hardware configuration of the typical power supply control system used by the APS magnets and the software commands supported by the PSCU.

  19. Space Station Freedom power supply commonality via modular design

    NASA Technical Reports Server (NTRS)

    Krauthamer, S.; Gangal, M. D.; Das, R.

    1990-01-01

    At mature operations, Space Station Freedom will need more than 2000 power supplies to feed housekeeping and user loads. Advanced technology power supplies from 20 to 250 W have been hybridized for terrestrial, aerospace, and industry applications in compact, efficient, reliable, lightweight packages compatible with electromagnetic interference requirements. The use of these hybridized packages as modules, either singly or in parallel, to satisfy the wide range of user power supply needs for all elements of the station is proposed. Proposed characteristics for the power supplies include common mechanical packaging, digital control, self-protection, high efficiency at full and partial loads, synchronization capability to reduce electromagnetic interference, redundancy, and soft-start capability. The inherent reliability is improved compared with conventional discrete component power supplies because the hybrid circuits use high-reliability components such as ceramic capacitors. Reliability is further improved over conventional supplies because the hybrid packages, which may be treated as a single part, reduce the parts count in the power supply.

  20. 49 CFR 393.23 - Power supply for lamps.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the exception of battery powered lamps used on projecting loads....

  1. 49 CFR 393.23 - Power supply for lamps.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the exception of battery powered lamps used on projecting loads....

  2. 49 CFR 393.23 - Power supply for lamps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the exception of battery powered lamps used on projecting loads....

  3. Proceedings of the Switched Power Workshop: Power Supply Working Group

    NASA Astrophysics Data System (ADS)

    Haseroth, H.; Hopkins, D.; Ikezi, H.; Kirbie, H. C.; Lincke, E.; Wilson, M.

    1989-04-01

    The power supply working group was assigned the problem of pulse charging the 3-MeV gun. The gun is a radial line structure that has two charging configurations: a single ring charged to 500 kV or nine rings charged from 100 to 200 kV. In either configuration, the pulsed source must rapidly charge the structure's ring(s) before breakdown can begin. The issues encountered in charging the structure can be divided into two categories. First, the charging system must be well matched to the gun structure. Proper impedance matching will avoid reflections and limit the fault current if the ring should spark. Second, several systems can achieve the wide range of charge voltages necessary. Some are better suited to high voltages, while others are better at low voltages. The following paragraphs will address the impedance matching issues and review three choices for pulse generators. A system for each type of source is described along with a very rough cost estimate.

  4. Small, efficient power supply for xenon lamps

    NASA Technical Reports Server (NTRS)

    Goodwin, J. E.

    1970-01-01

    Device, which operates from 28 V dc, has four sections, a preregulator, a dc-to-dc converter, a current regulator, and a high voltage starter. The unique characteristics of the individual sections are described.

  5. RHIC GAMMA TRANSITION JUMP POWER SUPPLY PROTOTYPE TEST.

    SciTech Connect

    MI,J.; GANETIS,G.; LOUIE,W.; BRUNO,D.; ZAPASEK,R.; SANDBERG,J.; ZHANG,W.

    2001-06-18

    This paper describes the principle and test results of the prototype RHIC Gamma Transition Jump Power Supply. The jump power supply principle is introduced and illustrated along with diagrams in this paper. The prototype is built with Insulated Gate Bipolar Transistors (IGBT) as current direction switch components. Optically coupled IGBT drivers are used for the jump control switch. The jump time among the power supplies is synchronized from 40 to 60 milliseconds to meet the RHIC beam transition-crossing requirement. The short jump time is needed to avoid particle loss and to preserve the initial bunch area during the transition, thus successfully transferring the ion beams from the acceleration RF system to storage system. There are a total of twenty four jump power supplies that will be used. They synchronously switch the direction of the magnets current while the beam is being accelerated through the transition to reach the top storage energy. Each power supply will energize a group of super conducting magnets, which consists of four magnets that are connected in series. At the end, test results are listed, accompanied with the dummy load current waveform and prototype power supply picture.

  6. AGS Fast spin resonance jump, magnets and power supplies

    SciTech Connect

    Glenn,J.W.; Huang, H.; Liaw, C. J.; Marneris, I.; Meng, W.; Mi, J. L.; Rosas, P.; Sandberg, J.; Tuozzolo, J.; Zhang, A.

    2009-05-04

    In order to cross more rapidly the 82 weak spin resonances caused by the horizontal tune and the partial snakes, we plan to jump the horizontal tune 82 times during the acceleration of polarized protons. The current in the magnets creating this tune jump will rise in 100 {micro}s, hold flat for about 4 ms and fan to zero in 100 {micro}s. Laminated beam transport quadrupole magnets have been recycled by installing new two turn coils and longitudinal laminated pole tip shims that reduce inductance and power supply current. The power supply uses a high voltage capacitor discharge to raise the magnet current, which is then switched to a low voltage supply, and then the current is switched back to the high voltage capacitor to zero the current. The current in each of the magnet pulses must match the order of magnitude change in proton momentum during the acceleration cycle. The magnet, power supply and operational experience are described.

  7. AGS tune jump power supply design and test

    SciTech Connect

    Mi, J.; Glenn, J.W.; Huang, H.; Marneris, I.; Rosas, P.; Sandberg, J.; Tan, Y.; Zhang, W.

    2011-03-28

    A horizontal tune jump system has been installed to overcome the horizontal intrinsic spin resonances, which requires jumping the horizontal tune 0.04 units 82 times, 41 up and 41 down. Two quadruple magnets have been installed in AGS ring to perform this. The pulsed magnet current ranges from about 140A near injection to about 1400A later. The current pulse rise and fall time are around 100uS and flat tops time is around 4mS. These quadruples have separated supplies. This tune jump pulse power supply employees all semiconductor parts as well as the main switches. During dummy load and magnet testing, the test results showed that the power supply could meet the specification. This article will describe some details of power supply simulation, design and testing. Some test waveforms and pictures are presented in this paper.

  8. Design and optimization of power supplies for wireless integrated microsystems

    NASA Astrophysics Data System (ADS)

    Albano, Fabio

    In this work, we developed a novel power supply for the WIMS-ERC intraocular sensor (WIMS-IOS), an autonomous and implantable system. This device is representative of a broad class of microscale devices, whose full implementation in environmental and medical systems will require significantly smaller power supplies; presently, battery systems represent 85% mass and 50% volume of typical devices. Strategies using both commercial and specially developed devices, using a variety of electrochemistries have been used. The smallest of the batteries reported to date, are thin-film lithium (Li) cells, using a chemical vapor deposition (CVD) or a pulsed laser deposition (PLD) approach. Thin film batteries fabricated with these techniques have achieved electrodes thicknesses less than 5mum (unpackaged), capacities of ˜100muAh/cm2 and footprints of 1cm2. However, clean-room fabrication and high power laser equipment needed for ceramic materials entail high cost (˜$300/Wh), and the elevated processing temperatures (500-720°C) and use of chemicals and etchants, make them incompatible with CMOS materials. Finally, the intrinsically high power (3.5-4.2V) of lithium chemistry complicates integration with low-voltage MEMS, since it necessitates voltage regulation. In our study we deposited thin film electrodes using physical vapor deposition (PVD), a low temperature (270-500°C) purely physical process in a vacuum ˜10 -7Torr. Our underlying hypothesis was that this technique would reduce intrinsic losses because of the high resulting precision, while allowing integration with chips because of more benign processing conditions to MEMS. Our specific objectives were to: (1) analyze commercial systems for the WIMS-IOS; (2) create batteries from commercial active materials; and finally (3) create test and integrate novel batteries. Commercial Zn/Ag batteries were selected using a previously developed system analyzer (POWER algorithm). Active materials from the same commercial

  9. Maximum Power Point Regulator System

    NASA Astrophysics Data System (ADS)

    Simola, J.; Savela, K.; Stenberg, J.; Tonicello, F.

    2011-10-01

    The target of the study done under the ESA contract No.17830/04/NL/EC (GSTP4) for Maximum Power Point Regulator System (MPPRS) was to investigate, design and test a modular power system (a core PCU) fulfilling requirement for maximum power transfer even after a single failure in the Power System by utilising a power concept without any potential and credible single point failure. The studied MPPRS concept is of a modular construction, able to track the MPP individually on each SA sections, maintaining its functionality and full power capability after a loss of a complete MPPR module (by utilizingN+1module).Various add-on DCDC converter topology candidates were investigated and redundancy, failure mechanisms and protection aspects were studied

  10. A unique power supply for the PEP II klystron at SLAC

    SciTech Connect

    Cassel, R.; Nguyen, M.N.

    1997-07-01

    Each of the eight 1.2 MW RF klystrons for the PEP-II storage rings require a 2.5 MVA DC power supply of 83 Kv at 23 amps. The design for the supply was base on three factors, low cost, small size to fit existing substation pads, and good protection against damage to the klystron including klystron gun arcs. The supply uses a 12 pulse 12.5 KV primary thyristor star point controller with primary filter inductor to provide rapid voltage control, good voltage regulation, and fast turn off during klystron tube faults. The supply also uses a unique secondary rectifier, filter capacitor configuration to minimize the energy available under a klystron fault. The voltage control is from 0--90 KV with a regulation of < 0.1% and voltage ripple of < 1% P-P, (< 0.2% RMS) above 60 KV. The supply utilizes a thyristor crowbar, which under a klystron tube arc limits the energy in the klystron arc to < 5 joules. If the thyristor crowbar is disabled the energy supplied is < 40 joules into the arc. The size of the supply was reduced small enough to fit the existing PEP transformer yard pads. The cost of the power supply was < $140 per KVA.

  11. 46 CFR 113.25-7 - Power supply overcurrent protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Power supply overcurrent protection. 113.25-7 Section 113.25-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-7 Power...

  12. 49 CFR 236.551 - Power supply voltage; requirement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.551 Power... 49 Transportation 4 2011-10-01 2011-10-01 false Power supply voltage; requirement. 236.551...

  13. Arc lamp power supply using a voltage multiplier

    NASA Technical Reports Server (NTRS)

    Leighty, Bradley D.

    1988-01-01

    A power supply is provided for an arc discharge lamp which includes a relatively low voltage high current power supply section and a high voltage starter circuit. The low voltage section includes a transformer, rectifier, variable resistor and a bank of capacitors, while the starter circuit comprises several diodes and capacitors connected as a Cockcroft-Walton multiplier. The starting circuit is effectively bypassed when the lamp arc is established and serves to automatically provide a high starting voltage to re-strike the lamp arc if the arc is extinguished by a power interruption.

  14. Expert systems for space power supply - Design, analysis, and evaluation

    NASA Technical Reports Server (NTRS)

    Cooper, Ralph S.; Thomson, M. Kemer; Hoshor, Alan

    1987-01-01

    The feasibility of applying expert systems to the conceptual design, analysis, and evaluation of space power supplies in particular, and complex systems in general is evaluated. To do this, the space power supply design process and its associated knowledge base were analyzed and characterized in a form suitable for computer emulation of a human expert. The existing expert system tools and the results achieved with them were evaluated to assess their applicability to power system design. Some new concepts for combining program architectures (modular expert systems and algorithms) with information about the domain were applied to create a 'deep' system for handling the complex design problem. NOVICE, a code to solve a simplified version of a scoping study of a wide variety of power supply types for a broad range of missions, has been developed, programmed, and tested as a concrete feasibility demonstration.

  15. A Robust Modular IGBT Power Supply for Innovative Confinement Concepts

    NASA Astrophysics Data System (ADS)

    Ziemba, Timothy; Miller, Kenneth; Prager, James

    2012-10-01

    Eagle Harbor Technologies (EHT) has developed an IGBT-based switching module for pulsed high power (> 10 MW) RF applications. These modules contain a control voltage supply (isolated to 30 kV) and fiber optically isolated drive circuitry, which allows for easy integration into a wide variety of power supply configurations. Each module is capable of switching 2.5 kA (pulsed) or at 1 kV or switching 100 kW (CW) up to megahertz frequencies with rise times of 40 ns. The modules are designed for precise switching control, which reduces jitter (< 5 ns) between modules, enabling robust series operation. EHT will present the final module design and performance results. In addition, data will be presented from two power supplies utilizing the EHT module: a 10 kV series stack that drives a resistive load at 500 A and a half bridge configuration that drives series resonant network with over 5 MW oscillating power.

  16. Fuel cell power supply with oxidant and fuel gas switching

    DOEpatents

    McElroy, J.F.; Chludzinski, P.J.; Dantowitz, P.

    1987-04-14

    This invention relates to a fuel cell vehicular power plant. Fuel for the fuel stack is supplied by a hydrocarbon (methanol) catalytic cracking reactor and CO shift reactor. A water electrolysis subsystem is associated with the stack. During low power operation part of the fuel cell power is used to electrolyze water with hydrogen and oxygen electrolysis products being stored in pressure vessels. During peak power intervals, viz, during acceleration or start-up, pure oxygen and pure hydrogen from the pressure vessel are supplied as the reaction gases to the cathodes and anodes in place of air and methanol reformate. This allows the fuel cell stack to be sized for normal low power/air operation but with a peak power capacity several times greater than that for normal operation. 2 figs.

  17. Fuel cell power supply with oxidant and fuel gas switching

    DOEpatents

    McElroy, James F.; Chludzinski, Paul J.; Dantowitz, Philip

    1987-01-01

    This invention relates to a fuel cell vehicular power plant. Fuel for the fuel stack is supplied by a hydrocarbon (methanol) catalytic cracking reactor and CO shift reactor. A water electrolysis subsystem is associated with the stack. During low power operation part of the fuel cell power is used to electrolyze water with hydrogen and oxygen electrolysis products being stored in pressure vessels. During peak power intervals, viz, during acceleration or start-up, pure oxygen and pure hydrogen from the pressure vessel are supplied as the reaction gases to the cathodes and anodes in place of air and methanol reformate. This allows the fuel cell stack to be sized for normal low power/air operation but with a peak power capacity several times greater than that for normal operation.

  18. Study of a High Voltage Ion Engine Power Supply

    NASA Technical Reports Server (NTRS)

    Stuart, Thomas A.; King, Roger J.; Mayer, Eric

    1996-01-01

    A complete laboratory breadboard version of a ion engine power converter was built and tested. This prototype operated on a line voltage of 80-120 Vdc, and provided output ratings of 1100 V at 1.8 kW, and 250 V at 20 mA. The high-voltage (HV) output voltage rating was revised from the original value of 1350 V at the beginning of the project. The LV output was designed to hold up during a 1-A surge current lasting up to 1 second. The prototype power converter included a internal housekeeping power supply which also operated from the line input. The power consumed in housekeeping was included in the overall energy budget presented for the ion engine converter. HV and LV output voltage setpoints were commanded through potentiometers. The HV converter itself reached its highest power efficiency of slightly over 93% at low line and maximum output. This would dip below 90% at high line. The no-load (rated output voltages, zero load current) power consumption of the entire system was less than 13 W. A careful loss breakdown shows that converter losses are predominately Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) conduction losses and HV rectifier snubbing losses, with the rectifier snubbing losses becoming predominant at high line. This suggests that further improvements in power efficiency could best be obtained by either developing a rectifier that was adequately protected against voltage overshoot with less snubbing, or by developing a pre-regulator to reduced the range of line voltage on the converter. The transient testing showed the converter to be fully protected against load faults, including a direct short-circuit from the HV output to the LV output terminals. Two currents sensors were used: one to directly detect any core ratcheting on the output transformer and re-initiate a soft start, and the other to directly detect a load fault and quickly shut down the converter for load protection. The finished converter has been extensively fault tested

  19. DIII-D power supply, design, and development

    SciTech Connect

    Nerem, A.

    1995-02-01

    An overview of the DIII-D power supply system with information details concerning the configuration, power ratings, acquisition costs, and cost scaling relevant to the design of ITER and other tokamaks is presented. The power supplies for the DIII-D tokamak were installed and commissioned during the late 1970`s and the beginning of the 1980`s. Several upgrades have been implemented during the last two years to solve increasing reliability problems encountered as the equipment aged, to provide enhanced operational flexibilities, and to enable operation at the higher power levels needed to provide experimental data relevant to the ITER and TPX design activities. These upgrades ranged from redesign of the power supply control systems to the replacement of vacuum circuit breakers which had become unreliable in service. A new interlock and protection system has also been implemented using the latest programmable logic controllers (PLC) and computer technology. These upgrades have been highly successful and are described to provide insight to many issues in the specification of high power converters. Power supply models used in the design of the DIII-D Plasma Control System are also described along with model verification test data. These models are being used in the development of a new advanced plasma control system for the DIII-D tokamak. Recent operational experience and results are presented.

  20. Power Quality Improvement in Bridgeless Ac-Dc Converter Based Multi-output Switched Mode Power Supply

    NASA Astrophysics Data System (ADS)

    Singh, Shihka; Singh, Bhim; Bhuvaneswari, G.; Bist, Vashist

    2014-12-01

    Computer power supplies are required to have multiple isolated regulated dc voltages with low ripple content and high input power factor at the utility interface. A dc-dc converter is used for obtaining these isolated multi-output dc voltages with excellent regulation. In this paper, a non-isolated ac-dc converter is proposed as the first stage converter to obtain a regulated dc output rather than using a simple uncontrolled diode bridge rectifier at the front end. A dc-dc converter is used at the second stage that has a high frequency transformer with multiple secondary windings to obtain different dc voltage levels at the output. The proposed bridgeless converter based power supply is designed using fundamental design equations, and different component values are calculated. Extensive simulations are carried out to demonstrate the improved performance of the proposed bridgeless converter based multi-output computer power supply at varying source voltages and load conditions. Experimental validation of the power supply is carried on a developed hardware prototype, and the test results are compared with the simulated performance for design verification.

  1. PUREX (SAMCONS) uninterruptible power supply (UPS) acceptance test procedure

    SciTech Connect

    Blackaby, W.B.

    1997-09-01

    This Acceptance Test Procedure for the PUREX Surveillance and Monitoring and Control System (SAMCONS) Uninterruptible Power Supply (UPS) provides for testing and verifying the proper operation of the control panel alarms and trouble functions, the 6roper functioning of the AC inverter, ability of the battery supply to maintain the SAMCONS load for a minimum of two hours , and proper interaction with the SAMCONS Video graphic displays for alarm displays.

  2. Precision control of high temperature furnaces using an auxiliary power supply and charged practice current flow

    DOEpatents

    Pollock, George G.

    1997-01-01

    Two power supplies are combined to control a furnace. A main power supply heats the furnace in the traditional manner, while the power from the auxiliary supply is introduced as a current flow through charged particles existing due to ionized gas or thermionic emission. The main power supply provides the bulk heating power and the auxiliary supply provides a precise and fast power source such that the precision of the total power delivered to the furnace is improved.

  3. Precision control of high temperature furnaces using an auxiliary power supply and charged particle current flow

    DOEpatents

    Pollock, G.G.

    1997-01-28

    Two power supplies are combined to control a furnace. A main power supply heats the furnace in the traditional manner, while the power from the auxiliary supply is introduced as a current flow through charged particles existing due to ionized gas or thermionic emission. The main power supply provides the bulk heating power and the auxiliary supply provides a precise and fast power source such that the precision of the total power delivered to the furnace is improved. 5 figs.

  4. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Construction work plans-power supply borrowers. 1710.252 Section 1710.252 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE GENERAL AND PRE-LOAN POLICIES AND PROCEDURES COMMON TO...

  5. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 11 2014-01-01 2014-01-01 false Construction work plans-power supply borrowers. 1710.252 Section 1710.252 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE GENERAL AND PRE-LOAN POLICIES AND PROCEDURES COMMON TO...

  6. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Construction work plans-power supply borrowers. 1710.252 Section 1710.252 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE GENERAL AND PRE-LOAN POLICIES AND PROCEDURES COMMON TO...

  7. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 11 2011-01-01 2011-01-01 false Construction work plans-power supply borrowers. 1710.252 Section 1710.252 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE GENERAL AND PRE-LOAN POLICIES AND PROCEDURES COMMON TO...

  8. SLAC Next-Generation High Availability Power Supply

    SciTech Connect

    Bellomo, P.; MacNair, D.; ,

    2010-06-11

    SLAC recently commissioned forty high availability (HA) magnet power supplies for Japan's ATF2 project. SLAC is now developing a next-generation N+1 modular power supply with even better availability and versatility. The goal is to have unipolar and bipolar output capability. It has novel topology and components to achieve very low output voltage to drive superconducting magnets. A redundant, embedded, digital controller in each module provides increased bandwidth for use in beam-based alignment, and orbit correction systems. The controllers have independent inputs for connection to two external control nodes. Under fault conditions, they sense failures and isolate the modules. Power supply speed mitigates the effects of fault transients and obviates subsequent magnet standardization. Hot swap capability promises higher availability and other exciting benefits for future, more complex, accelerators, and eventually the International Linear Collider project.

  9. PEP-II Large Power Supplies Rebuild Program at SLAC

    SciTech Connect

    Bellomo, P.; Lipari, J.J.; de Lira, A.C.; Rafael, F.S.; /SLAC

    2005-05-17

    Seven large power supplies (LGPS) with output ratings from 72kW to 270kW power PEP-II quad magnets in the electron-positron collider region. These supplies have posed serious maintenance and reliability problems since they were installed in 1997, resulting in loss of accelerator availability. A redesign/rebuild program was undertaken by the SLAC Power Conversion Department. During the 2004 summer shutdown all the control circuits in these supplies were redesigned and replaced. A new PWM control board, programmable logic controller, and touch panel have been installed to improve LGPS reliability, and to make troubleshooting easier. In this paper we present the details of this rebuilding program and results.

  10. A Modular, IGBT Driven, Ignitron Switched, Optically Controlled Power Supply

    NASA Astrophysics Data System (ADS)

    Carroll, Evan; von der Linden, Jens; You, Setthivoine

    2013-10-01

    An experiment to investigate the dynamics of canonical flux tubes at the University of Washington uses two high energy pulsed power supplies to generate and sustain the plasma discharge. A modular 240 μF , 12 kV DC capacitor based power supply, discharged by ignitron, has been developed specifically for this application. Design considerations include minimizing inductance, rapid switching, fast rise times, and electrically isolated control. An optically coupled front panel and fast IGBT ignitron drive circuit, sequenced manually or by software, control the charge and discharge of the power supply. A complete, sequenced charge/discharge has been successfully tested with a dummy load, producing a peak current of 100 kA and a rise time of 25 μs . This work was sponsored in part by the US DOE Grant DE-SC0010340.

  11. Power Supply Reliability Estimates for Experimental Fusion Facilities

    SciTech Connect

    Cadwallader, lee; Pinna, Tonio; Petersen, Peter

    2006-11-01

    This paper presents the results of a task to analyze the operating experience data for large, pulsed power supplies used at the DIII-D tokamak. This activity supports the International Thermonuclear Experimental Reactor (ITER) project by giving fusion-specific reliability values for large power supplies that energize neutral beams and magnets. These failure rate data are necessary to perform system availability calculations and to make estimates of the frequency of safety-significant events (e.g., power supply arcs or fires) that might occur in other fusion facilities such as ITER. The analysis shows that the DIII-D data results compare well with the results of similar data analysis work that the Italian National Agency for New Technologies, Energy and the Environment (ENEA) has performed on the JET tokamak and compare fairly with data from two accelerators.

  12. A number of upgrades on RHIC power supply system

    SciTech Connect

    Mi, C.; Bruno, D.; Drozd, J.; Nolan, T.; Orsatti, F.; Heppener, G.; Di Lieto, A.; Schultheiss, C.; Samms, T.; Zapasek, R.; Sandberg, J.

    2015-05-03

    This year marks the 15th run for the Relativistic Heavy Ion Collider (RHIC). Operation of a reliable superconducting magnet power supply system is a key factor of an accelerator’s performance. Over the past 15 years, the RHIC power supply group has made many improvements to increase the machine availability and reduce failures. During these past 15 years of operating RHIC a lot of problems have been solved or addressed. In this paper some of the essential upgrades/improvements are discussed.

  13. Low Power, High Voltage Power Supply with Fast Rise/Fall Time

    NASA Technical Reports Server (NTRS)

    Bearden, Douglas B. (Inventor)

    2007-01-01

    A low power, high voltage power supply system includes a high voltage power supply stage and a preregulator for programming the power supply stage so as to produce an output voltage which is a predetermined fraction of a desired voltage level. The power supply stage includes a high voltage, voltage doubler stage connected to receive the output voltage from the preregulator and for, when activated, providing amplification of the output voltage to the desired voltage level. A first feedback loop is connected between the output of the preregulator and an input of the preregulator while a second feedback loop is connected between the output of the power supply stage and the input of the preregulator.

  14. Low power, high voltage power supply with fast rise/fall time

    NASA Technical Reports Server (NTRS)

    Bearden, Douglas B. (Inventor)

    2007-01-01

    A low power, high voltage power supply system includes a high voltage power supply stage and a preregulator for programming the power supply stage so as to produce an output voltage which is a predetermined fraction of a desired voltage level. The power supply stage includes a high voltage, voltage doubler stage connected to receive the output voltage from the preregulator and for, when activated, providing amplification of the output voltage to the desired voltage level. A first feedback loop is connected between the output of the preregulator and an input of the preregulator while a second feedback loop is connected between the output of the power supply stage and the input of the preregulator.

  15. Power supplies and quench protection for the Tokamak Physics Experiment

    SciTech Connect

    Neumeyer, C.L.

    1994-07-01

    The Tokamak Physics Experiment (TPX) is an advanced tokamak project aimed at the production of quasi-steady state plasmas with advanced shape, heating, and particle control. TPX is to be built at the Princeton Plasma Physics Laboratory (PPPL) using many of the facilities from the Tokamak Fusion Test Reactor (TFTR). First plasma is scheduled for the year 2000. TPX will be the first tokamak to utilize superconducting (SC) magnets in both the toroidal field (TF) and poloidal field (PF) systems. This is a new feature which requires not only a departure from the traditional tokamak power supply schemes but also that ultra-reliable quench protection devices be used to rapidly discharge the stored energy from the magnets in the event of a quench. This paper describes the plan and basis for the adaptation and augmentation of the PPPL/TFTR power system facilities to supply TPX. Following a description of the basic operational requirements, four major areas are addressed, namely the AC power system, the TF power supply, the PF power supply, and quench protection for the TF and PF systems.

  16. Preliminary design of a mobile lunar power supply

    NASA Astrophysics Data System (ADS)

    Schmitz, Paul C.; Kenny, Barbara H.; Fulmer, Christopher R.

    A preliminary design for a Stirling isotope power system for use as a mobile lunar power supply is presented. Performance and mass of the components required for the system are estimated. These estimates are based on power requirements and the operating environment. Optimizations routines are used to determine minimum mass operational points. Shielding for the isotope system are given as a function of the allowed dose, distance from the source, and the time spent near the source. The technologies used in the power conversion and radiator systems are taken from ongoing research in the Civil Space Technology Initiative (CSTI) program.

  17. Preliminary design of a mobile lunar power supply

    NASA Astrophysics Data System (ADS)

    Schmitz, Paul C.; Kenny, Barbara H.; Fulmer, Christopher

    A preliminary design for a Stirling isotope power system for use as a mobile lunar power supply is presented. Performance and mass of the components required for the system are estimated. These estimates are based on power requirements and the operating environment. Optimization routines are used to determine minimum mass operational points. Shielding for the isotope system is given as a function of the allowed dose, distance from the source, and the time spent near the source. The technologies used in the power conversion and radiator systems are taken from research in the Civil Space Technology Initiative (CSTI) program.

  18. Preliminary design of a mobile lunar power supply

    NASA Technical Reports Server (NTRS)

    Schmitz, Paul C.; Kenny, Barbara H.; Fulmer, Christopher

    1991-01-01

    A preliminary design for a Stirling isotope power system for use as a mobile lunar power supply is presented. Performance and mass of the components required for the system are estimated. These estimates are based on power requirements and the operating environment. Optimization routines are used to determine minimum mass operational points. Shielding for the isotope system is given as a function of the allowed dose, distance from the source, and the time spent near the source. The technologies used in the power conversion and radiator systems are taken from research in the Civil Space Technology Initiative (CSTI) program.

  19. Preliminary design of a mobile lunar power supply

    NASA Technical Reports Server (NTRS)

    Schmitz, Paul C.; Kenny, Barbara H.; Fulmer, Christopher R.

    1991-01-01

    A preliminary design for a Stirling isotope power system for use as a mobile lunar power supply is presented. Performance and mass of the components required for the system are estimated. These estimates are based on power requirements and the operating environment. Optimizations routines are used to determine minimum mass operational points. Shielding for the isotope system are given as a function of the allowed dose, distance from the source, and the time spent near the source. The technologies used in the power conversion and radiator systems are taken from ongoing research in the Civil Space Technology Initiative (CSTI) program.

  20. Arc-Jet Power Supply And Starting Circuit

    NASA Technical Reports Server (NTRS)

    Gruber, Robert P.

    1988-01-01

    Power efficiency high, current regulated, and starting automatic. New circuit for starting arc jets and controlling them in steady operation capable of high power efficiency and constructed in lightweight form. Feedback control system keeps arc-jet current nearly constant, once arc struck by starting pulse. Circuit made of commercially available components. Design capable of high power efficiency.

  1. Bimode uninterruptible power supply compatibility in renewable hybrid energy systems

    SciTech Connect

    Bower, W. ); O'Sullivan, G. )

    1990-08-01

    Inverters installed in renewable hybrid energy systems are typically used in a stand-alone mode to supply ac power to loads from battery storage when the engine-generator is not being used. Similarities in topology and in the performance requirements of the standby uninterruptible power supply (UPS) system and the hybrid system suggest the UPS could be used in hybrid energy systems. Another alternative to inverters with add-on charging circuits or standby UPS hardware is the Bimode UPS. The bimode UPS uses common circuitry and power components for dc to ac inversion and battery charging. It also provides an automatic and nearly instantaneous ac power transfer function when the engine-generator is started or stopped. The measured operating and transfer characteristics of a bimode UPS in a utility system and in a hybrid system are presented. The applicability of the bimode UPS to hybrid systems and its compatibility in a PV/engine-generator hybrid system are given.

  2. Dual Power Supplies for PEP-II Injection Kickers

    SciTech Connect

    Olszewski, J; Decker, F.-J.; Iverson, R.H.; Kulikov, A.; Pappas, C.; /SLAC

    2005-05-25

    Originally the PEP-II injection kickers were powered by one power supply. Since the kicker magnets where not perfectly matched, the stored beam got excited by about 7% of the maximum kicker amplitude. This led to luminosity losses which were especially obvious for trickle injection when the detector is on for data taking. Therefore two independent power supplies with thyratrons in the tunnel next to the kicker magnet were installed. This also reduces the necessary power by about a factor of four since there are no long cables that have to be charged. The kickers are now independently adjustable to eliminate any non-closure of the kicker system and therefore excitation of the stored beam. Setup, commissioning and fine tuning of this system are discussed.

  3. Minimizing the mass of a potential railgun power supply

    SciTech Connect

    Johnson, D.E.; Noel, A.P.; Clements, W.D. )

    1991-01-01

    This paper reports on the design of a pulsed power supply to deliver 5 MJ at 1 MA at 1 shot per second to a railgun. The supply stores energy at low current in the primary of the hydrogen-cooled transformer. A switch opens the primary circuit to transfer energy to the secondary, stepping the current up to 1 MA. The authors are studying the relationship between the transformer and switch to determine how the total power supply mass can be minimized. Vacuum interrupters and gate-turn-off thyristors are used in the switch. Switch mass dominates the system, accounting for 85% of the total mass. The switch must absorb the uncoupled energy of the transformer. Low transformer coupling requires large capacitors. Even with high coupling, capacitors account for 75 to 85% of the switch mass. If transformer coupling increases, the uncoupled energy decreases, resulting in low capacitor mass.

  4. Fermilab's Booster Correction Element Power Supply Silicon Temperature Rise

    SciTech Connect

    Krafczyk, G.; Jensen, C.; Pfeffer, H.; Warchol, G.; /Fermilab

    2009-05-01

    Fermilab is in the process of upgrading its Booster Correction Element System to include full field correction element magnets to correct position and chromaticity throughout the booster cycle. For good reliability of the switchmode power supplies designed to power the magnets, it is important to limit both the maximum temperature and the repetitive temperature cycling of the silicon junctions of the switching elements. We will describe how we measured these parameters and the results of our measurements.

  5. 33. View of data converter and power supply for TR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. View of data converter and power supply for TR system in transmitter building no. 102, mezzanine level. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  6. 47 CFR 80.965 - Reserve power supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... includes a battery, proof of the ability of the battery to operate continuously for the required time must...) of this section, no part of the reserve power supply must have excessive temperature rise, nor must the specific gravity or voltage of any battery be below the 90 percent discharge point....

  7. 47 CFR 80.965 - Reserve power supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... includes a battery, proof of the ability of the battery to operate continuously for the required time must...) of this section, no part of the reserve power supply must have excessive temperature rise, nor must the specific gravity or voltage of any battery be below the 90 percent discharge point....

  8. 77 FR 48177 - Fuel Oil Systems for Emergency Power Supplies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-13

    ... COMMISSION Fuel Oil Systems for Emergency Power Supplies AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide; extension of comment period. SUMMARY: On July 5, 2012 (77 FR 39745), the U.S. Nuclear... ADAMS. II. Background On July 5, 2012 (77 FR 39745), the NRC published a notice of issuance...

  9. 78 FR 36278 - Fuel Oil Systems for Emergency Power Supplies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... Draft Regulatory Guide, DG-1282 on July 5, 2012 (77 FR 39745) for a 60-day public comment period. The public comment period was extended until September 28, 2012 (77 FR 48177). Public comments were received... COMMISSION Fuel Oil Systems for Emergency Power Supplies AGENCY: Nuclear Regulatory Commission....

  10. 10 CFR 429.37 - Class A external power supplies.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Class A external power supplies. 429.37 Section 429.37 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER... of the estimated energy consumption of a basic model for which consumers would favor lower...